1
|
Li J, Léonce E, Coutellier C, Boutin C, Chighine K, Rivron C, Davidson A, Berthault P. Integrated Stopped-Flow Device for the Study of Porous Materials Using Hyperpolarized 129Xe NMR. Anal Chem 2024; 96:9430-9437. [PMID: 38819299 DOI: 10.1021/acs.analchem.4c00490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2024]
Abstract
A simple, low-cost, and efficient device is proposed for the study of porous materials via NMR using small gas probes. Mainly built through additive manufacturing and being equipped with a radiofrequency solenoid microcoil, it only requires tiny quantities of sample and/or gas and is particularly suited for hyperpolarized xenon. The performances of this device have been accessed on a commercial sample of MCM-41 exhibiting multiporosity. Both the delivery mode of hyperpolarized xenon and the stopped-flow system are judged as efficient according to 2D 129Xe self-diffusion and EXSY experiments.
Collapse
Affiliation(s)
- Jing Li
- NIMBE, CEA, CNRS, Université de Paris Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| | - Estelle Léonce
- NIMBE, CEA, CNRS, Université de Paris Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| | - Corentin Coutellier
- NIMBE, CEA, CNRS, Université de Paris Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| | - Céline Boutin
- NIMBE, CEA, CNRS, Université de Paris Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| | - Kévin Chighine
- NIMBE, CEA, CNRS, Université de Paris Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| | - Charles Rivron
- NIMBE, CEA, CNRS, Université de Paris Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| | - Anne Davidson
- Laboratoire de Réactivité de Surface, Sorbonne Universités, UPMC Université Paris 06, UMR CNRS 7197, 4 Place Jussieu, 75005 Paris, France
| | - Patrick Berthault
- NIMBE, CEA, CNRS, Université de Paris Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| |
Collapse
|
2
|
Preclinical MRI Using Hyperpolarized 129Xe. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27238338. [PMID: 36500430 PMCID: PMC9738892 DOI: 10.3390/molecules27238338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/15/2022] [Accepted: 11/17/2022] [Indexed: 12/05/2022]
Abstract
Although critical for development of novel therapies, understanding altered lung function in disease models is challenging because the transport and diffusion of gases over short distances, on which proper function relies, is not readily visualized. In this review we summarize progress introducing hyperpolarized 129Xe imaging as a method to follow these processes in vivo. The work is organized in sections highlighting methods to observe the gas replacement effects of breathing (Gas Dynamics during the Breathing Cycle) and gas diffusion throughout the parenchymal airspaces (3). We then describe the spectral signatures indicative of gas dissolution and uptake (4), and how these features can be used to follow the gas as it enters the tissue and capillary bed, is taken up by hemoglobin in the red blood cells (5), re-enters the gas phase prior to exhalation (6), or is carried via the vasculature to other organs and body structures (7). We conclude with a discussion of practical imaging and spectroscopy techniques that deliver quantifiable metrics despite the small size, rapid motion and decay of signal and coherence characteristic of the magnetically inhomogeneous lung in preclinical models (8).
Collapse
|
3
|
Han KS, Burton SD, Walter ED, Shin Y, Kuang W, Simmons KL. Microsized Pore Structure Determination in EPDM Rubbers Using High-Pressure 129Xe NMR Techniques. J Phys Chem B 2022; 126:3135-3142. [PMID: 35420819 DOI: 10.1021/acs.jpcb.1c09189] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Microsized pore parameters, such as pore size and distance between pores in a series of model EPDM rubbers, were determined in situ under the pressure of 500 psi using 129Xe nuclear magnetic resonance (NMR) techniques: spin-lattice (T1) and spin-spin (T2) relaxation measurements, pulsed-field gradient (PFG) NMR, and two-dimensional exchange spectroscopy (2D EXSY). The T1/T2 (≫1) ratio for the xenon confined in the pores is larger than that for nonconfined free xenon. This suggests that almost the entire pore surface interacts with xenon atoms like a closed pore. While these pores still connect each other through very narrow diffusion/exchange channels, it is possible to observe the echo decay in PFG-NMR and cross-peaks in 2D EXSY. The results show that both diffusion (Dpore ≈ 2.1 × 10-10 m2/s) and exchange (exchange rate, τexch = a few tens of milliseconds) of xenon between a pore within the material and outer surface are prolonged. The exchange distances (l), which correspond to the xenon gas penetration depth, were estimated to be 70-100 μm based on the measured diffusion coefficients and exchange rate (1/τexch). NMR diffraction analysis reveals that pore size (a) and pore distance (b) are on the order of magnitude of micrometers and tens of micrometers, while the diffusion coefficients of xenon gas in the diffusion channels (Deff) are about 10-8 m2/s. Overall, this study suggests that the pores with a few micrometers connected through very narrow flowing channels with the length of several tens of micrometers are developed 70 to 100 μm below the rubber surface. Furthermore, the overall steady-state diffusion of xenon is slower, approximately 2 orders of magnitudes, than the diffusion in the channel between the pores. The pore and exchange distances correlated with the composition of rubbers showed that the properties of EPDM rubber as a high-pressure gas barrier could be improved by reducing the size of cracks and the depth of gas penetration by the addition of both carbon black and silica fillers.
Collapse
Affiliation(s)
- Kee Sung Han
- Physical and Computational Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Sarah D Burton
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Eric D Walter
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Yongsoon Shin
- Physical and Computational Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Wenbin Kuang
- Energy and Environmental Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Kevin L Simmons
- Energy and Environmental Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| |
Collapse
|
4
|
Kowalczuk J, Łapiński A, Stolarczyk E, Demchuk OM, Kubiński K, Janeczko M, Martyna A, Masłyk M, Turczyniak-Surdacka S. New Supramolecular Drug Carriers: The Study of Organogel Conjugated Gold Nanoparticles. Molecules 2021; 26:7462. [PMID: 34946545 PMCID: PMC8708427 DOI: 10.3390/molecules26247462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 11/26/2021] [Accepted: 12/02/2021] [Indexed: 11/17/2022] Open
Abstract
An aqueous solution of sodium citrate stabilized gold nanoparticles (AuNP) in the presence of N-lauroyl-L-alanine (C12ALA) forms a stable gel. The structure of the gel and the distribution profile of AuNP in it were analyzed. Will nanoparticles separated from each other with sodium citrate behave in the same way in solution and trapped in the gel matrix? Will the spatial limitation of solvent molecules aggregate nanoparticles and destroy their homogeneity? These questions are very important from the point of view of the use of gold nanoparticles, trapped in the gel structure as carriers of drugs in the slow-release process. The lack of homogeneity of this distribution will have a major impact on the rate of release of the appropriate amount of therapeutic drug from the matrix. In this work, we attempt to answer these questions. The performed biological assays revealed that both C12ALA and C12ALA-AuNP show an excellent level of biological neutrality. They might be used as a transporting medium for a drug delivery without affecting the drug's activity.
Collapse
Affiliation(s)
- Joanna Kowalczuk
- Institute of Molecular Physics, Polish Academy of Sciences, 60-179 Poznan, Poland;
| | - Andrzej Łapiński
- Institute of Molecular Physics, Polish Academy of Sciences, 60-179 Poznan, Poland;
| | - Elżbieta Stolarczyk
- Łukasiewicz Research Network, Institute of Industrial Chemistry, 01-793 Warsaw, Poland;
| | - Oleg M. Demchuk
- Department of Molecular Biology, Faculty of Science and Health, The John Paul II Catholic University of Lublin, 20-708 Lublin, Poland; (K.K.); (M.J.); (A.M.); (M.M.)
| | - Konrad Kubiński
- Department of Molecular Biology, Faculty of Science and Health, The John Paul II Catholic University of Lublin, 20-708 Lublin, Poland; (K.K.); (M.J.); (A.M.); (M.M.)
| | - Monika Janeczko
- Department of Molecular Biology, Faculty of Science and Health, The John Paul II Catholic University of Lublin, 20-708 Lublin, Poland; (K.K.); (M.J.); (A.M.); (M.M.)
| | - Aleksandra Martyna
- Department of Molecular Biology, Faculty of Science and Health, The John Paul II Catholic University of Lublin, 20-708 Lublin, Poland; (K.K.); (M.J.); (A.M.); (M.M.)
| | - Maciej Masłyk
- Department of Molecular Biology, Faculty of Science and Health, The John Paul II Catholic University of Lublin, 20-708 Lublin, Poland; (K.K.); (M.J.); (A.M.); (M.M.)
| | | |
Collapse
|
5
|
Liu J, Fan Y, Qiu T, Ge X, Deng S, Xing D. A novel pulse sequence and inversion algorithm of three-dimensional low field NMR technique in unconventional resources. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2019; 303:67-74. [PMID: 31004986 DOI: 10.1016/j.jmr.2019.04.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 04/09/2019] [Accepted: 04/10/2019] [Indexed: 06/09/2023]
Abstract
Compared with two-dimensional (2D) nuclear magnetic resonance (NMR) technique like correlations among the transversal relaxation time (T2), the longitudinal relaxation time (T1), and the diffusion coefficient correlation (D), three-dimensional (3D) NMR technique is superior with the complete measurement of T2, T1, and D simultaneously. It can solve the problem of overlaps in 2D correlation map and is helpful to characterize relaxation components in unconventional resources such as tight gas and oil shale. However, the existed 3D NMR technique is restricted due to the loss of short relaxation information and the inversion inaccuracy that caused by the incomplete measurement of the diffusion editing window. We developed a tri-window pulse sequence to collect the full decaying information of porous media. In the first window, the inversion-recovery pulse sequence is applied for T1 encoding. In the second window, D and T2 are encoded by an adjustable continuous pulse field gradient and echo spacing (TE). In the last window, CPMG with the shortest TE is used to acquire diffusion-free relaxation information. We then proposed a joint inversion algorithm named "composite-data-processing" to obtain the 3D correlation map. The algorithm adopts the dimension reduction technique and the truncated singular value decomposition (TSVD) to speed up the inversion process and enhance the inversion stability. Numerical simulations show that good estimations of the inversion results are obtained at different signal to noise ratios (SNRs). Our results suggest that the novel pulse sequence and inversion algorithm of 3D NMR can be effectively applied to the exploration of unconventional resources.
Collapse
Affiliation(s)
- Jianyu Liu
- School of Geosciences in China University of Petroleum, Qingdao 266580, PR China; Laboratory for Marine Mineral Resources, Qingdao National Laboratory for Marine Science and Technology, Qingdao 266071, PR China
| | - Yiren Fan
- School of Geosciences in China University of Petroleum, Qingdao 266580, PR China; Laboratory for Marine Mineral Resources, Qingdao National Laboratory for Marine Science and Technology, Qingdao 266071, PR China.
| | - Tingcong Qiu
- School of Geosciences in China University of Petroleum, Qingdao 266580, PR China; Laboratory for Marine Mineral Resources, Qingdao National Laboratory for Marine Science and Technology, Qingdao 266071, PR China
| | - Xinmin Ge
- School of Geosciences in China University of Petroleum, Qingdao 266580, PR China; Laboratory for Marine Mineral Resources, Qingdao National Laboratory for Marine Science and Technology, Qingdao 266071, PR China
| | - Shaogui Deng
- School of Geosciences in China University of Petroleum, Qingdao 266580, PR China; Laboratory for Marine Mineral Resources, Qingdao National Laboratory for Marine Science and Technology, Qingdao 266071, PR China
| | - Donghui Xing
- School of Geosciences in China University of Petroleum, Qingdao 266580, PR China; Laboratory for Marine Mineral Resources, Qingdao National Laboratory for Marine Science and Technology, Qingdao 266071, PR China
| |
Collapse
|
6
|
Yablonskiy DA, Sukstanskii AL, Quirk JD. Diffusion lung imaging with hyperpolarized gas MRI. NMR IN BIOMEDICINE 2017; 30:10.1002/nbm.3448. [PMID: 26676342 PMCID: PMC4911335 DOI: 10.1002/nbm.3448] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2015] [Revised: 10/20/2015] [Accepted: 10/22/2015] [Indexed: 05/28/2023]
Abstract
Lung imaging using conventional 1 H MRI presents great challenges because of the low density of lung tissue, lung motion and very fast lung tissue transverse relaxation (typical T2 * is about 1-2 ms). MRI with hyperpolarized gases (3 He and 129 Xe) provides a valuable alternative because of the very strong signal originating from inhaled gas residing in the lung airspaces and relatively slow gas T2 * relaxation (typical T2 * is about 20-30 ms). However, in vivo human experiments should be performed very rapidly - usually during a single breath-hold. In this review, we describe the recent developments in diffusion lung MRI with hyperpolarized gases. We show that a combination of the results of modeling of gas diffusion in lung airspaces and diffusion measurements with variable diffusion-sensitizing gradients allows the extraction of quantitative information on the lung microstructure at the alveolar level. From an MRI scan of less than 15 s, this approach, called in vivo lung morphometry, allows the provision of quantitative values and spatial distributions of the same physiological parameters as measured by means of 'standard' invasive stereology (mean linear intercept, surface-to-volume ratio, density of alveoli, etc.). In addition, the approach makes it possible to evaluate some advanced Weibel parameters characterizing lung microstructure: average radii of alveolar sacs and ducts, as well as the depth of their alveolar sleeves. Such measurements, providing in vivo information on the integrity of pulmonary acinar airways and their changes in different diseases, are of great importance and interest to a broad range of physiologists and clinicians. We also discuss a new type of experiment based on the in vivo lung morphometry technique combined with quantitative computed tomography measurements, as well as with gradient echo MRI measurements of hyperpolarized gas transverse relaxation in the lung airspaces. Such experiments provide additional information on the blood vessel volume fraction, specific gas volume and length of the acinar airways, and allow the evaluation of lung parenchymal and non-parenchymal tissue. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
| | | | - James D Quirk
- Department of Radiology, Washington University, St. Louis, MO, USA
| |
Collapse
|
7
|
Barskiy DA, Coffey AM, Nikolaou P, Mikhaylov DM, Goodson BM, Branca RT, Lu GJ, Shapiro MG, Telkki VV, Zhivonitko VV, Koptyug IV, Salnikov OG, Kovtunov KV, Bukhtiyarov VI, Rosen MS, Barlow MJ, Safavi S, Hall IP, Schröder L, Chekmenev EY. NMR Hyperpolarization Techniques of Gases. Chemistry 2017; 23:725-751. [PMID: 27711999 PMCID: PMC5462469 DOI: 10.1002/chem.201603884] [Citation(s) in RCA: 110] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2016] [Indexed: 01/09/2023]
Abstract
Nuclear spin polarization can be significantly increased through the process of hyperpolarization, leading to an increase in the sensitivity of nuclear magnetic resonance (NMR) experiments by 4-8 orders of magnitude. Hyperpolarized gases, unlike liquids and solids, can often be readily separated and purified from the compounds used to mediate the hyperpolarization processes. These pure hyperpolarized gases enabled many novel MRI applications including the visualization of void spaces, imaging of lung function, and remote detection. Additionally, hyperpolarized gases can be dissolved in liquids and can be used as sensitive molecular probes and reporters. This Minireview covers the fundamentals of the preparation of hyperpolarized gases and focuses on selected applications of interest to biomedicine and materials science.
Collapse
Affiliation(s)
- Danila A Barskiy
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
| | - Aaron M Coffey
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
| | - Panayiotis Nikolaou
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
| | | | - Boyd M Goodson
- Southern Illinois University, Department of Chemistry and Biochemistry, Materials Technology Center, Carbondale, IL, 62901, USA
| | - Rosa T Branca
- Department of Physics and Astronomy, Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA
| | - George J Lu
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
| | - Mikhail G Shapiro
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
| | | | - Vladimir V Zhivonitko
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Igor V Koptyug
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Oleg G Salnikov
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Kirill V Kovtunov
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Valerii I Bukhtiyarov
- Boreskov Institute of Catalysis SB RAS, 5 Acad. Lavrentiev Pr., 630090, Novosibirsk, Russia
| | - Matthew S Rosen
- MGH/A.A. Martinos Center for Biomedical Imaging, Boston, MA, 02129, USA
| | - Michael J Barlow
- Respiratory Medicine Department, Queen's Medical Centre, University of Nottingham Medical School, Nottingham, NG7 2UH, UK
| | - Shahideh Safavi
- Respiratory Medicine Department, Queen's Medical Centre, University of Nottingham Medical School, Nottingham, NG7 2UH, UK
| | - Ian P Hall
- Respiratory Medicine Department, Queen's Medical Centre, University of Nottingham Medical School, Nottingham, NG7 2UH, UK
| | - Leif Schröder
- Molecular Imaging, Department of Structural Biology, Leibniz-Institut für Molekulare Pharmakologie (FMP), 13125, Berlin, Germany
| | - Eduard Y Chekmenev
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
- Russian Academy of Sciences, 119991, Moscow, Russia
| |
Collapse
|
8
|
Abstract
This chapter reviews the recent development of an NMR method to obtain information on site selective hyperpolarized samples by Parahydrogen Induced Polarization (PHIP) where the chemical reaction is carried out at high magnetic fields (PASADENA). The method relies on the acquisition of J-spectra in PHIP, which differ from J-spectra for thermally polarized species due to different evolution in the time domain during application of a Carr–Purcell–Meiboom–Gill (CPMG) sequence. PHIP and thermal polarizations give rise to signals which are centered in spectral positions shifted by half of the spectral width, giving rise to two useful results. On one hand, the antiphase character of PASADENA spectra implies a partial peak cancellation, as J-couplings introduce a splitting in the signal of a few Hz. The acquisition of J-spectra renders line width typically of 0.1 Hz, avoiding cancellation. A second aspect to be considered in PHIP is the suppression of antiphase signals due to overlap with ones steaming from thermal polarization at the same frequency. The frequency discrimination of the method enables the detection of hydrogenation even for very low reaction rates. Thus, the method is referred to as Parahydrogen Discriminated PHIP (PhD-PHIP). Simulations of PhD-PHIP with gas phase NMR are presented.
Collapse
Affiliation(s)
- Rodolfo H. Acosta
- FaMAF-Universidad Nacional de Córdoba, IFEG-CONICET 5016 Córdoba Argentina
| | - Ignacio Prina
- FaMAF-Universidad Nacional de Córdoba, IFEG-CONICET 5016 Córdoba Argentina
| | | |
Collapse
|
9
|
Yablonskiy DA, Sukstanskii AL, Quirk JD, Woods JC, Conradi MS. Probing lung microstructure with hyperpolarized noble gas diffusion MRI: theoretical models and experimental results. Magn Reson Med 2016; 71:486-505. [PMID: 23554008 DOI: 10.1002/mrm.24729] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The introduction of hyperpolarized gases ((3)He and (129)Xe) has opened the door to applications for which gaseous agents are uniquely suited-lung MRI. One of the pulmonary applications, diffusion MRI, relies on measuring Brownian motion of inhaled hyperpolarized gas atoms diffusing in lung airspaces. In this article we provide an overview of the theoretical ideas behind hyperpolarized gas diffusion MRI and the results obtained over the decade-long research. We describe a simple technique based on measuring gas apparent diffusion coefficient (ADC) and an advanced technique, in vivo lung morphometry, that quantifies lung microstructure both in terms of Weibel parameters (acinar airways radii and alveolar depth) and standard metrics (mean linear intercept, surface-to-volume ratio, and alveolar density) that are widely used by lung researchers but were previously available only from invasive lung biopsy. This technique has the ability to provide unique three-dimensional tomographic information on lung microstructure from a less than 15 s MRI scan with results that are in good agreement with direct histological measurements. These safe and sensitive diffusion measurements improve our understanding of lung structure and functioning in health and disease, providing a platform for monitoring the efficacy of therapeutic interventions in clinical trials.
Collapse
|
10
|
Ruppert K. Biomedical imaging with hyperpolarized noble gases. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2014; 77:116701. [PMID: 25360484 DOI: 10.1088/0034-4885/77/11/116701] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Hyperpolarized noble gases (HNGs), polarized to approximately 50% or higher, have led to major advances in magnetic resonance (MR) imaging of porous structures and air-filled cavities in human subjects, particularly the lung. By boosting the available signal to a level about 100 000 times higher than that at thermal equilibrium, air spaces that would otherwise appear as signal voids in an MR image can be revealed for structural and functional assessments. This review discusses how HNG MR imaging differs from conventional proton MR imaging, how MR pulse sequence design is affected and how the properties of gas imaging can be exploited to obtain hitherto inaccessible information in humans and animals. Current and possible future imaging techniques, and their application in the assessment of normal lung function as well as certain lung diseases, are described.
Collapse
|
11
|
Acosta RH, Blümler P, Münnemann K, Spiess HW. Mixture and dissolution of laser polarized noble gases: spectroscopic and imaging applications. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2012; 66:40-69. [PMID: 22980033 DOI: 10.1016/j.pnmrs.2012.03.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2011] [Accepted: 03/20/2012] [Indexed: 06/01/2023]
Affiliation(s)
- Rodolfo H Acosta
- FAMAF, Universidad Nacional de Córdoba, IFEG - CONICET, Córdoba, Argentina
| | | | | | | |
Collapse
|
12
|
Laun FB, Kuder TA, Wetscherek A, Stieltjes B, Semmler W. NMR-based diffusion pore imaging. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2012; 86:021906. [PMID: 23005784 DOI: 10.1103/physreve.86.021906] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2012] [Revised: 05/23/2012] [Indexed: 06/01/2023]
Abstract
Nuclear magnetic resonance (NMR) diffusion experiments offer a unique opportunity to study boundaries restricting the diffusion process. In a recent Letter [Phys. Rev. Lett. 107, 048102 (2011)], we introduced the idea and concept that such diffusion experiments can be interpreted as NMR imaging experiments. Consequently, images of closed pores, in which the spins diffuse, can be acquired. In the work presented here, an in-depth description of the diffusion pore imaging technique is provided. Image artifacts due to gradient profiles of finite duration, field inhomogeneities, and surface relaxation are considered. Gradients of finite duration lead to image blurring and edge enhancement artifacts. Field inhomogeneities have benign effects on diffusion pore images, and surface relaxation can lead to a shrinkage and shift of the pore image. The relation between boundary structure and the imaginary part of the diffusion weighted signal is analyzed, and it is shown that information on pore coherence can be obtained without the need to measure the phase of the diffusion weighted signal. Moreover, it is shown that quite arbitrary gradient profiles can be used for diffusion pore imaging. The matrices required for numerical calculations are stated and provided as supplemental material.
Collapse
Affiliation(s)
- Frederik Bernd Laun
- Medical Physics in Radiology, German Cancer Research Center, DKFZ, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | | | | | | | | |
Collapse
|
13
|
Zheng W, Cleveland ZI, Möller HE, Driehuys B. Gradient-induced longitudinal relaxation of hyperpolarized noble gases in the fringe fields of superconducting magnets used for magnetic resonance. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2011; 208:284-90. [PMID: 21134771 PMCID: PMC3026078 DOI: 10.1016/j.jmr.2010.11.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2010] [Revised: 11/09/2010] [Accepted: 11/09/2010] [Indexed: 05/09/2023]
Abstract
When hyperpolarized noble gases are brought into the bore of a superconducting magnet for magnetic resonance imaging (MRI) or spectroscopy studies, the gases must pass through substantial field gradients, which can cause rapid longitudinal relaxation. In this communication, we present a means of calculating this spatially dependent relaxation rate in the fringe field of typical magnets. We then compare these predictions to experimental measurements of (3)He relaxation at various positions near a medium-bore 2-T small animal MRI system. The calculated and measured relaxation rates on the central axis of the magnet agree well and show a maximum (3)He relaxation rate of 3.83×10(-3) s(-1) (T(1)=4.4 min) at a distance of 47 cm from the magnet isocenter. We also show that if this magnet were self-shielded, its minimum T(1) would drop to 1.2 min. In contrast, a typical self-shielded 1.5-T clinical MRI scanner will induce a minimum on-axis T(1) of 12 min. Additionally, we show that the cylindrically symmetric fields of these magnets enable gradient-induced relaxation to be calculated using only knowledge of the on-axis longitudinal field, which can either be measured directly or calculated from a simple field model. Thus, while most MRI magnets employ complex and proprietary current configurations, we show that their fringe fields and the resulting gradient-induced relaxation are well approximated by simple solenoid models. Finally, our modeling also demonstrates that relaxation rates can increase by nearly an order of magnitude at radial distances equivalent to the solenoid radius.
Collapse
Affiliation(s)
- Wangzhi Zheng
- Triangle Universities Nuclear Laboratory and Department of Physics, Duke University, Durham, NC 27708, USA
| | - Zackary I. Cleveland
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
| | - Harald E. Möller
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Bastiaan Driehuys
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
| |
Collapse
|
14
|
Kowalczuk J, Tritt-Goc J. A possible application of magnetic resonance imaging for pharmaceutical research. Eur J Pharm Sci 2010; 42:354-64. [PMID: 21195171 DOI: 10.1016/j.ejps.2010.12.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2010] [Revised: 12/16/2010] [Accepted: 12/23/2010] [Indexed: 11/28/2022]
Abstract
Magnetic resonance imaging (MRI) is a non-destructive and non-invasive method, the experiment can be conducted in situ and allows the studying of the sample and the different processes in vitro or in vivo. 1D, 2D or 3D imaging can be undertaken. MRI is nowadays most widely used in medicine as a clinical diagnostic tool, but has still seen limited application in the food and pharmaceutical sciences. The different imaging pulse sequences of MRI allow to image the processes that take place in a wide scale range from ms (dissolution of compact tablets) to hours (hydration of drug delivery systems) for mobile as well as for rigid spins, usually protons. The paper gives examples of MRI application of in vitro imaging of pharmaceutical dosage based on hydroxypropyl methylcellulose which have focused on water-penetration, diffusion, polymer swelling, and drug release, characterized with respect to other physical parameters such as pH and the molecular weight of polymer. Tetracycline hydrochloride was used as a model drug. NMR imaging of density distributions and fast kinetics of the dissolution behavior of compact tablets is presented for paracetamol tablets.
Collapse
Affiliation(s)
- Joanna Kowalczuk
- Institute of Molecular Physics, Polish Academy of Sciences, M. Smoluchowskiego 17, 60-179 Poznan, Poland
| | | |
Collapse
|
15
|
Yadav NN, Torres AM, Price WS. NMR q-space imaging of macroscopic pores using singlet spin states. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2010; 204:346-348. [PMID: 20371196 DOI: 10.1016/j.jmr.2010.03.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2010] [Revised: 03/01/2010] [Accepted: 03/16/2010] [Indexed: 05/29/2023]
Abstract
NMR q-space imaging is a powerful non-invasive technique used to determine structural characteristics of pores in applications ranging from medical to material science. To date, the application of q-space imaging has primarily been limited to microscopic pores in part because of limitations of the effective observation time due to relaxation. Here we report on the use of singlet spin states for NMR q-space imaging, which allow significantly greater observation times. This opens the way for studying larger pores in materials such as biological tissue, emulsions, and rocks.
Collapse
Affiliation(s)
- Nirbhay N Yadav
- Nanoscale Organisation and Dynamics Group, College of Health and Science, University of Western Sydney, Campbelltown Campus, Locked Bag 1797, Penrith South DC, NSW 1797, Australia
| | | | | |
Collapse
|
16
|
Romoscanu AI, Fenollosa A, Acquistapace S, Gunes D, Martins-Deuchande T, Clausen P, Mezzenga R, Nydén M, Zick K, Hughes E. Structure, diffusion, and permeability of protein-stabilized monodispersed oil in water emulsions and their gels: a self-diffusion NMR study. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2010; 26:6184-6192. [PMID: 20369894 DOI: 10.1021/la100774q] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Self-diffusion NMR is used to investigate monodispersed oil in water emulsions and the subsequent gel formed by removing the water through evaporation. The radius of the oil droplets in the emulsions is measured using a number of diffusion methods based on the measurement of the mean squared displacement of the oil, water, and tracer molecules. The results are consistent with the known size of the emulsions. Bragg-like reflections due to the restricted diffusion of the water around the oil droplets are observed due to the low polydispersity of the emulsions and the dense packing. The resulting data are fitted to a pore glass model to give the diameter of both the pools of interstitial water and the oil droplets. In the gel, information on the residual three-dimensional structure is obtained using the short time behavior of the effective diffusion coefficient to give the surface to volume ratio of the residual protein network structure. The values for the surface to volume ratio are found to be consistent with the expected increase of the surface area of monodisperse droplets forming a gel network. At long diffusion observation times, the permeability of the network structure is investigated by diffusion NMR to give a complete picture of the colloidal system considered.
Collapse
|
17
|
|
18
|
Marchione AA, McCord EF. Spectral separation of gaseous fluorocarbon mixtures and measurement of diffusion constants by 19F gas phase DOSY NMR. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2009; 201:34-38. [PMID: 19703788 DOI: 10.1016/j.jmr.2009.07.027] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2009] [Revised: 07/15/2009] [Accepted: 07/30/2009] [Indexed: 05/28/2023]
Abstract
Diffusion-ordered (DOSY) NMR techniques have for the first time been applied to the spectral separation of mixtures of fluorinated gases by diffusion rates. A mixture of linear perfluoroalkanes from methane to hexane was readily separated at 25 degrees C in an ordinary experimental setup with standard DOSY pulse sequences. Partial separation of variously fluorinated ethanes was also achieved. The constants of self-diffusion of a set of pure perfluoroalkanes were obtained at pressures from 0.25 to 1.34 atm and temperatures from 20 to 122 degrees C. Under all conditions there was agreement within 20% of experimental self-diffusion constant D and values calculated by the semiempirical Fuller method.
Collapse
Affiliation(s)
- Alexander A Marchione
- DuPont Central Research and Development, Experimental Station, Wilmington, DE 19803, USA.
| | | |
Collapse
|
19
|
Cleveland ZI, Möller HE, Hedlund LW, Driehuys B. Continuously infusing hyperpolarized 129Xe into flowing aqueous solutions using hydrophobic gas exchange membranes. J Phys Chem B 2009; 113:12489-99. [PMID: 19702286 PMCID: PMC2747043 DOI: 10.1021/jp9049582] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Hyperpolarized (HP) (129)Xe yields high signal intensities in nuclear magnetic resonance (NMR) and, through its large chemical shift range of approximately 300 ppm, provides detailed information about the local chemical environment. To exploit these properties in aqueous solutions and living tissues requires the development of methods for efficiently dissolving HP (129)Xe over an extended time period. To this end, we have used commercially available gas exchange modules to continuously infuse concentrated HP (129)Xe into flowing liquids, including rat whole blood, for periods as long as one hour and have demonstrated the feasibility of dissolved-phase MR imaging with submillimeter resolution within minutes. These modules, which exchange gases using hydrophobic microporous polymer membranes, are compatible with a variety of liquids and are suitable for infusing HP (129)Xe into the bloodstream in vivo. Additionally, we have developed a detailed mathematical model of the infused HP (129)Xe signal dynamics that should be useful in designing improved infusion systems that yield even higher dissolved HP (129)Xe signal intensities.
Collapse
|
20
|
Agulles-Pedrós L, Acosta RH, Blümler P, Spiess HW. Resolution enhancement in MRI of laser polarized 3He by control of diffusion. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2009; 197:56-62. [PMID: 19128992 DOI: 10.1016/j.jmr.2008.12.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2008] [Revised: 12/03/2008] [Accepted: 12/03/2008] [Indexed: 05/27/2023]
Abstract
Diffusion of atoms or molecules in presence of magnetic field gradients not only attenuates the NMR signal but also leads to distortions close to restricting boundaries. This phenomenon is most evident in imaging with laser polarized (LP) noble gases. Diffusion of gases can be manipulated, however, by admixing inert gases of different molecular weight. In this work we analyze the effect of mixing LP-(3)He with SF(6) on the image quality of a phantom consisting of an arrangement of capillaries with different diameters. Admixing buffer gases of higher molecular weight changes the contrast and offers a means to record images with high spatial and time resolution. Additionally we demonstrate how distortions due to edge enhancement can be reduced even for long timed MRI-sequences.
Collapse
Affiliation(s)
- L Agulles-Pedrós
- Max Planck-Institute for Polymer Research, Ackermannweg 10, 55128 Mainz, Germany
| | | | | | | |
Collapse
|
21
|
Carl M, Wilson Miller G, Mugler JP, Rohrbaugh S, Tobias WA, Cates GD. Measurement of hyperpolarized gas diffusion at very short time scales. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2007; 189:228-40. [PMID: 17936048 PMCID: PMC2194618 DOI: 10.1016/j.jmr.2007.09.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2007] [Revised: 09/12/2007] [Accepted: 09/12/2007] [Indexed: 05/15/2023]
Abstract
We present a new pulse sequence for measuring very-short-time-scale restricted diffusion of hyperpolarized noble gases. The pulse sequence is based on concatenating a large number of bipolar diffusion-sensitizing gradients to increase the diffusion attenuation of the MR signal while maintaining a fundamentally short diffusion time. However, it differs in several respects from existing methods that use oscillating diffusion gradients for this purpose. First, a wait time is inserted between neighboring pairs of gradient pulses; second, consecutive pulse pairs may be applied along orthogonal axes; and finally, the diffusion-attenuated signal is not simply read out at the end of the gradient train but is periodically sampled during the wait times between neighboring pulse pairs. The first two features minimize systematic differences between the measured (apparent) diffusion coefficient and the actual time-dependent diffusivity, while the third feature optimizes the use of the available MR signal to improve the precision of the diffusivity measurement in the face of noise. The benefits of this technique are demonstrated using theoretical calculations, Monte-Carlo simulations of gas diffusion in simple geometries, and experimental phantom measurements in a glass sphere containing hyperpolarized (3)He gas. The advantages over the conventional single-bipolar approach were found to increase with decreasing diffusion time, and thus represent a significant step toward making accurate surface-to-volume measurements in the lung airspaces.
Collapse
Affiliation(s)
- Michael Carl
- Department of Physics, University of Virginia, Charlottesville, VA, USA
| | - G. Wilson Miller
- Center for In-Vivo Hyperpolarized Gas MR Imaging, Department of Radiology, University of Virginia, Charlottesville, VA, USA
- *Correspondence should be addressed to: G. Wilson Miller, Ph.D., Radiology Research, Box 801339, 409 Lane Rd., Room 1146, University of Virginia, Charlottesville, VA 22908, , Phone: 434-243-9216, Fax: 434-924-9435
| | - John P. Mugler
- Center for In-Vivo Hyperpolarized Gas MR Imaging, Department of Radiology, University of Virginia, Charlottesville, VA, USA
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
| | - Scott Rohrbaugh
- Department of Physics, University of Virginia, Charlottesville, VA, USA
| | - William A. Tobias
- Department of Physics, University of Virginia, Charlottesville, VA, USA
| | - Gordon D. Cates
- Department of Physics, University of Virginia, Charlottesville, VA, USA
- Center for In-Vivo Hyperpolarized Gas MR Imaging, Department of Radiology, University of Virginia, Charlottesville, VA, USA
| |
Collapse
|
22
|
Sun PZ. Improved diffusion measurement in heterogeneous systems using the magic asymmetric gradient stimulated echo (MAGSTE) technique. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2007; 187:177-83. [PMID: 17500019 PMCID: PMC2075361 DOI: 10.1016/j.jmr.2007.04.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2006] [Revised: 04/18/2007] [Accepted: 04/18/2007] [Indexed: 05/15/2023]
Abstract
A magic asymmetric gradient stimulated echo (MAGSTE) sequence was recently proposed to improve molecular diffusion measurements in the presence of spatially varying background gradients. Its effectiveness has been demonstrated previously with simulated background gradients and in phantoms that contain bulk susceptibility differences. In this study, we investigated the MAGSTE technique in microscopically heterogeneous systems, and compared it with the conventional bipolar pulsed gradient stimulated echo (bPGSTE) sequence. We demonstrated that the MASGTE measurements, compared to the bPGSTE method, varied significantly less when the diffusion encoding/decoding interval (delta) was changed. In addition, the MAGSTE technique provided good characterization of the surface area-to-volume ratio for heterogeneous systems investigated in this study. In sum, this study showed that the MAGSTE technique provided diffusion measurements superior to those of the bPGSTE sequence, especially in the presence of severe heterogeneous background gradients.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA.
| |
Collapse
|
23
|
Parsons EC, Does MD, Gore JC. Temporal diffusion spectroscopy: theory and implementation in restricted systems using oscillating gradients. Magn Reson Med 2006; 55:75-84. [PMID: 16342147 DOI: 10.1002/mrm.20732] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The theory of temporal diffusion spectra is reviewed. In contrast to q-space spectroscopy, which measures the displacement spectrum of spins in a spatial domain, the spectral density of the velocity correlation function (VCF) in the temporal domain is considered. It is demonstrated that casting diffusion in this domain may facilitate measurements of microscopic geometry and the decomposition of the diffusion signal into components due to disperse flow and restricted diffusion. An oscillating gradient (OG) method of diffusion spectroscopy was developed and implemented. Microscopic pore sizes, surface-to-volume ratios (S/Vs), and diffusion path tortuosities were extracted from model systems using this method. Cases are discussed in which this type of experiment may allow the characterization of pore geometry when spatial domain experiments fail. OGs may be combined with imaging sequences to map complex patterns of diffusion and flow. Moreover, scalar apparent diffusion coefficient (ADC) measurements in complex biological systems may be subtly dependent on specific pulse sequence parameters. Thus, scalar ADC measurements using gradient pulses with different frequency spectra may give different results. Conversely, the frequency dependence of motion-sensitizing gradient pulses may be exploited to deduce the origin of ADC changes.
Collapse
Affiliation(s)
- Edward C Parsons
- Department of Applied Physics, Yale University, New Haven, Connecticut, USA.
| | | | | |
Collapse
|
24
|
Abstract
Hyperpolarized gases have found a steadily increasing range of applications in nuclear magnetic resonance (NMR) and NMR imaging (MRI). They can be regarded as a new class of MR contrast agent or as a way of greatly enhancing the temporal resolution of the measurement of processes relevant to areas as diverse as materials science and biomedicine. We concentrate on the properties and applications of hyperpolarized xenon. This review discusses the physics of producing hyperpolarization, the NMR-relevant properties of 129Xe, specific MRI methods for hyperpolarized gases, applications of xenon to biology and medicine, polarization transfer to other nuclear species and low-field imaging.
Collapse
Affiliation(s)
- Ana-Maria Oros
- Institute of Medicine, Research Centre Jiilich, 52425 Jülich, Germany.
| | | |
Collapse
|
25
|
|
26
|
Codd SL, Altobelli SA. A PGSE study of propane gas flow through model porous bead packs. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2003; 163:16-22. [PMID: 12852903 DOI: 10.1016/s1090-7807(03)00111-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
We present a study of the probability density for molecular displacements of gas flowing through bead packs. The three bead packs to be described are composed of polydispersed porous PVC particles, 500 microm glass spheres, and 300 microm polystyrene spheres. A range of velocities (1 cm s(-1) to 1 m s(-1)) and observation times (3-500 ms), hence transport distances, are presented. For comparison we also measure the propagators for water flow in the polystyrene sphere pack. The exchange time between the moving and the stagnant portions of the flow is a strong function of the diffusion coefficient of the fluid. Comparing the propagators between water and propane flowing in similar porous media makes this clear. The gas propagators, for flowing and diffusing molecules, consistently show a feature at the average pore diameter. This feature has previously been observed for similar Peclet number studies in smaller monodispersed bead packs using liquids, but is now demonstrated for larger beads with gas. We analyze and discuss these propagators in the physically intuitive propagator space and also in the well-understood Fourier q space. The extension of NMR PGSE experiments to gas systems allows flow and diffusion information to be obtained over a wider range of length and time scales than with liquids, and also for a new range of physical environments and systems. Interactions between stochastic and deterministic motion are fundamental to the theoretical description of transport in porous media, and the time and length scale dependences are central to an understanding of the resultant dispersive motion.
Collapse
Affiliation(s)
- S L Codd
- New Mexico Resonance, Albuquerque, NM, USA.
| | | |
Collapse
|
27
|
Mair RW, Wang R, Rosen MS, Candela D, Cory DG, Walsworth RL. Applications of controlled-flow laser-polarized xenon gas to porous and granular media study. Magn Reson Imaging 2003; 21:287-92. [PMID: 12850720 DOI: 10.1016/s0730-725x(03)00156-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
We report initial NMR studies of continuous flow laser-polarized xenon gas, both in unrestricted tubing, and in a model porous media. The study uses Pulsed Gradient Spin Echo-based techniques in the gas-phase, with the aim of obtaining more sophisticated information than just translational self-diffusion coefficients. Pulsed Gradient Echo studies of continuous flow laser-polarized xenon gas in unrestricted tubing indicate clear diffraction minima resulting from a wide distribution of velocities in the flow field. The maximum velocity experienced in the flow can be calculated from this minimum, and is seen to agree with the information from the complete velocity spectrum, or motion propagator, as well as previously published images. The susceptibility of gas flows to parameters such as gas mixture content, and hence viscosity, are observed in experiments aimed at identifying clear structural features from echo attenuation plots of gas flow in porous media. Gas-phase NMR scattering, or position correlation flow-diffraction, previously clearly seen in the echo attenuation data from laser-polarized xenon flowing through a 2 mm glass bead pack is not so clear in experiments using a different gas mixture. A propagator analysis shows most gas in the sample remains close to static, while a small portion moves through a presumably near-unimpeded path at high velocities.
Collapse
Affiliation(s)
- R W Mair
- Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138, USA.
| | | | | | | | | | | |
Collapse
|
28
|
Mortuza MG, Anala S, Pavlovskaya GE, Dieken TJ, Meersmann T. Spin-exchange optical pumping of high-density xenon-129. J Chem Phys 2003. [DOI: 10.1063/1.1539042] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
|
29
|
Mair RW, Rosen MS, Wang R, Cory DG, Walsworth RL. Diffusion NMR methods applied to xenon gas for materials study. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2002; 40:S29-S39. [PMID: 12807139 DOI: 10.1002/mrc.1114] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
We report initial NMR studies of (i) xenon gas diffusion in model heterogeneous porous media and (ii) continuous flow laser-polarized xenon gas. Both areas utilize the pulsed gradient spin-echo (PGSE) techniques in the gas phase, with the aim of obtaining more sophisticated information than just translational self-diffusion coefficients--a brief overview of this area is provided in the Introduction. The heterogeneous or multiple-length scale model porous media consisted of random packs of mixed glass beads of two different sizes. We focus on observing the approach of the time-dependent gas diffusion coefficient, D(t) (an indicator of mean squared displacement), to the long-time asymptote, with the aim of understanding the long-length scale structural information that may be derived from a heterogeneous porous system. We find that D(t) of imbibed xenon gas at short diffusion times is similar for the mixed bead pack and a pack of the smaller sized beads alone, hence reflecting the pore surface area to volume ratio of the smaller bead sample. The approach of D(t) to the long-time limit follows that of a pack of the larger sized beads alone, although the limiting D(t) for the mixed bead pack is lower, reflecting the lower porosity of the sample compared to that of a pack of mono-sized glass beads. The Pade approximation is used to interpolate D(t) data between the short- and long-time limits. Initial studies of continuous flow laser-polarized xenon gas demonstrate velocity-sensitive imaging of much higher flows than can generally be obtained with liquids (20-200 mm s-1). Gas velocity imaging is, however, found to be limited to a resolution of about 1 mm s-1 owing to the high diffusivity of gases compared with liquids. We also present the first gas-phase NMR scattering, or diffusive-diffraction, data, namely flow-enhanced structural features in the echo attenuation data from laser-polarized xenon flowing through a 2 mm glass bead pack.
Collapse
Affiliation(s)
- R W Mair
- Harvard-Smithsonian Center for Astrophysics, Cambridge, Massachusetts 02138, USA.
| | | | | | | | | |
Collapse
|
30
|
Möller HE, Chen XJ, Saam B, Hagspiel KD, Johnson GA, Altes TA, de Lange EE, Kauczor HU. MRI of the lungs using hyperpolarized noble gases. Magn Reson Med 2002; 47:1029-51. [PMID: 12111949 DOI: 10.1002/mrm.10173] [Citation(s) in RCA: 273] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The nuclear spin polarization of the noble gas isotopes (3)He and (129)Xe can be increased using optical pumping methods by four to five orders of magnitude. This extraordinary gain in polarization translates directly into a gain in signal strength for MRI. The new technology of hyperpolarized (HP) gas MRI holds enormous potential for enhancing sensitivity and contrast in pulmonary imaging. This review outlines the physics underlying the optical pumping process, imaging strategies coping with the nonequilibrium polarization, and effects of the alveolar microstructure on relaxation and diffusion of the noble gases. It presents recent progress in HP gas MRI and applications ranging from MR microscopy of airspaces to imaging pulmonary function in patients and suggests potential directions for future developments.
Collapse
Affiliation(s)
- Harald E Möller
- Max-Planck-Institut für neuropsychologische Forschung, Leipzig, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Mair RW, Sen PN, Hürlimann MD, Patz S, Cory DG, Walsworth RL. The narrow pulse approximation and long length scale determination in xenon gas diffusion NMR studies of model porous media. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2002; 156:202-212. [PMID: 12165255 DOI: 10.1006/jmre.2002.2540] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
We report a systematic study of xenon gas diffusion NMR in simple model porous media, random packs of mono-sized glass beads, and focus on three specific areas peculiar to gas-phase diffusion. These topics are: (i) diffusion of spins on the order of the pore dimensions during the application of the diffusion encoding gradient pulses in a PGSE experiment (breakdown of the narrow pulse approximation and imperfect background gradient cancellation), (ii) the ability to derive long length scale structural information, and (iii) effects of finite sample size. We find that the time-dependent diffusion coefficient, D(t), of the imbibed xenon gas at short diffusion times in small beads is significantly affected by the gas pressure. In particular, as expected, we find smaller deviations between measured D(t) and theoretical predictions as the gas pressure is increased, resulting from reduced diffusion during the application of the gradient pulse. The deviations are then completely removed when water D(t) is observed in the same samples. The use of gas also allows us to probe D(t) over a wide range of length scales and observe the long time asymptotic limit which is proportional to the inverse tortuosity of the sample, as well as the diffusion distance where this limit takes effect (approximately 1-1.5 bead diameters). The Padé approximation can be used as a reference for expected xenon D(t) data between the short and the long time limits, allowing us to explore deviations from the expected behavior at intermediate times as a result of finite sample size effects. Finally, the application of the Padé interpolation between the long and the short time asymptotic limits yields a fitted length scale (the Padé length), which is found to be approximately 0.13b for all bead packs, where b is the bead diameter.
Collapse
Affiliation(s)
- R W Mair
- Harvard-Smithsonian Center for Astrophysics, Cambridge, Massachusetts 02138, USA
| | | | | | | | | | | |
Collapse
|
32
|
Butler JP, Mair RW, Hoffmann D, Hrovat MI, Rogers RA, Topulos GP, Walsworth RL, Patz S. Measuring surface-area-to-volume ratios in soft porous materials using laser-polarized xenon interphase exchange nuclear magnetic resonance. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2002; 14:L297-304. [PMID: 12741395 PMCID: PMC2194751 DOI: 10.1088/0953-8984/14/13/103] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
We demonstrate a minimally invasive nuclear magnetic resonance (NMR) technique that enables determination of the surface-area-to-volume ratio (S/V) of soft porous materials from measurements of the diffusive exchange of laser-polarized 129Xe between gas in the pore space and 129Xe dissolved in the solid phase. We apply this NMR technique to porous polymer samples and find approximate agreement with destructive stereological measurements of S/V obtained with optical confocal microscopy. Potential applications of laser-polarized xenon interphase exchange NMR include measurements of in vivo lung function in humans and characterization of gas chromatography columns.
Collapse
Affiliation(s)
- J P Butler
- Harvard School of Public Health, Boston, MA 02115, USA
| | | | | | | | | | | | | | | |
Collapse
|
33
|
Goodson BM. Nuclear magnetic resonance of laser-polarized noble gases in molecules, materials, and organisms. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2002; 155:157-216. [PMID: 12036331 DOI: 10.1006/jmre.2001.2341] [Citation(s) in RCA: 299] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
The sensitivity of conventional nuclear magnetic resonance (NMR) techniques is fundamentally limited by the ordinarily low spin polarization achievable in even the strongest NMR magnets. However, by transferring angular momentum from laser light to electronic and nuclear spins, optical pumping methods can increase the nuclear spin polarization of noble gases by several orders of magnitude, thereby greatly enhancing their NMR sensitivity. This review describes the principles and magnetic resonance applications of laser-polarized noble gases. The enormous sensitivity enhancement afforded by optical pumping can be exploited to permit a variety of novel NMR experiments across numerous disciplines. Many such experiments are reviewed, including the void-space imaging of organisms and materials, NMR and MRI of living tissues, probing structure and dynamics of molecules in solution and on surfaces, NMR sensitivity enhancement via polarization transfer, and low-field NMR and MRI.
Collapse
Affiliation(s)
- Boyd M Goodson
- Materials Sciences Division, Lawrence Berkeley National Laboratory and Department of Chemistry, University of California, Berkeley 94720-1460, USA
| |
Collapse
|
34
|
|
35
|
Koptyug IV, Ilyina LY, Matveev AV, Sagdeev RZ, Parmon VN, Altobelli SA. Liquid and gas flow and related phenomena in monolithic catalysts studied by 1H NMR microimaging. Catal Today 2001. [DOI: 10.1016/s0920-5861(01)00396-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
36
|
Loureiro de Sousa P, Abergel D, Lallemand JY. Experimental time saving in NMR measurement of time dependent diffusion coefficients. Chem Phys Lett 2001. [DOI: 10.1016/s0009-2614(01)00575-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
37
|
Fujiwara H, Kimura A, Yanagawa Y, Kamiya T, Hattori M, Hiraga T. Relaxation behavior of laser-polarized (129)Xe gas: size dependency and wall effect of the T(1) relaxation time in glass and gelatin bulbs. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2001; 150:156-160. [PMID: 11384174 DOI: 10.1006/jmre.2001.2327] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Size dependency of the relaxation time T(1) was measured for laser-polarized (129)Xe gas encapsulated in different sized cavities made by glass bulbs or gelatin capsules. The use of laser-polarized gas enhances the sensitivity a great deal, making it possible to measure the longer (129)Xe relaxation time in quite a short time. The size dependency is analyzed on the basis of the kinetic theory of gases and a relationship is derived in which the relaxation rate is connected with the square inverse of the diameter of the cavity. Such an analysis provides a novel parameter which denotes the wall effect on the relaxation rate when a gas molecule collides with the surface once in a second. The relaxation time of (129)Xe gas is also dependent on the material which forms the cavity. This dependency is large and the relaxation study using polarized (129)Xe gas is expected to offer important information about the state of the matter of the cavity wall.
Collapse
Affiliation(s)
- H Fujiwara
- School of Allied Health Sciences, Faculty of Medicine, Osaka University, 1-7 Yamada-Oka, Suita, Osaka 565-0871, Japan.
| | | | | | | | | | | |
Collapse
|
38
|
Wong GP, Mair RW, Walsworth RL, Cory DG. Measurement of persistence in 1D diffusion. PHYSICAL REVIEW LETTERS 2001; 86:4156-4159. [PMID: 11328119 DOI: 10.1103/physrevlett.86.4156] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2000] [Indexed: 05/23/2023]
Abstract
Using a novel NMR scheme we observed persistence in 1D gas diffusion. Analytical approximations and numerical simulations have indicated that for an initially random array of spins undergoing diffusion, the probability p(t) that the average spin magnetization in a given region has not changed sign (i.e., "persists") up to time t follows a power law t(-straight theta), where straight theta depends on the dimensionality of the system. Using laser-polarized 129Xe gas, we prepared an initial "quasirandom" 1D array of spin magnetization and then monitored the ensemble's evolution due to diffusion using real-time NMR imaging. Our measurements are consistent with analytical and numerical predictions of straight theta approximately 0.12.
Collapse
Affiliation(s)
- G P Wong
- Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, Massachusetts 02138, USA
| | | | | | | |
Collapse
|
39
|
Mair RW, Hürlimann MD, Sen PN, Schwartz LM, Patz S, Walsworth RL. Tortuosity measurement and the effects of finite pulse widths on xenon gas diffusion NMR studies of porous media. Magn Reson Imaging 2001; 19:345-51. [PMID: 11445310 DOI: 10.1016/s0730-725x(01)00247-8] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
We have extended the utility of NMR as a technique to probe porous media structure over length scales of approximately 100-2000 microm by using the spin 1/2 noble gas 129Xe imbibed into the system's pore space. Such length scales are much greater than can be probed with NMR diffusion studies of water-saturated porous media. We utilized Pulsed Gradient Spin Echo NMR measurements of the time-dependent diffusion coefficient, D(t), of the xenon gas filling the pore space to study further the measurements of both the pore surface-area-to-volume ratio, S/V(p), and the tortuosity (pore connectivity) of the medium. In uniform-size glass bead packs, we observed D(t) decreasing with increasing t, reaching an observed asymptote of approximately 0.62-0.65D(0), that could be measured over diffusion distances extending over multiple bead diameters. Measurements of D(t)/D(0) at differing gas pressures showed this tortuosity limit was not affected by changing the characteristic diffusion length of the spins during the diffusion encoding gradient pulse. This was not the case at the short time limit, where D(t)/D(0) was noticeably affected by the gas pressure in the sample. Increasing the gas pressure, and hence reducing D(0) and the diffusion during the gradient pulse served to reduce the previously observed deviation of D(t)/D(0) from the S/V(p) relation. The Pade approximation is used to interpolate between the long and short time limits in D(t). While the short time D(t) points lay above the interpolation line in the case of small beads, due to diffusion during the gradient pulse on the order of the pore size, it was also noted that the experimental D(t) data fell below the Pade line in the case of large beads, most likely due to finite size effects.
Collapse
Affiliation(s)
- R W Mair
- Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138, USA.
| | | | | | | | | | | |
Collapse
|
40
|
Chen XJ, Hedlund LW, Möller HE, Chawla MS, Maronpot RR, Johnson GA. Detection of emphysema in rat lungs by using magnetic resonance measurements of 3He diffusion. Proc Natl Acad Sci U S A 2000; 97:11478-81. [PMID: 11027348 PMCID: PMC17225 DOI: 10.1073/pnas.97.21.11478] [Citation(s) in RCA: 142] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Emphysema is a pulmonary disease characterized by alveolar wall destruction, resulting in enlargement of gas exchange spaces without fibrosis. This condition is a part of chronic obstructive pulmonary disease (COPD), which causes 3.5% of deaths worldwide [Anonymous (1990) World Health Stat. Q. Special, 1-51] and contributes greatly to the global burden of disease [Murray, C. J. & Lopez, A. D. (1996) Science 274, 740-743]. Alveolar regeneration has been shown in animal models and could have potential for clinical treatment of early-stage emphysema. However, current techniques for detection of emphysema are not sensitive at the initial stages. Early-stage human panacinar emphysema is modeled in elastase-treated animals. Here, we provide an in vivo imaging method for differentiating normal and emphysematous rat lungs by measuring the apparent diffusion coefficient (ADC) of hyperpolarized (3)He by using magnetic resonance imaging. These data show that the ADC is significantly larger in elastase-treated rats, indicating alveolar expansion. Whereas these rats were clinically asymptomatic, conventional histology confirmed presence of injury. Our results indicate that measurement of the hyperpolarized (3)He ADC can be a valuable research tool and has potential application in the clinical setting.
Collapse
Affiliation(s)
- X J Chen
- Center for In Vivo Microscopy, Duke University Medical Center, Durham, North Carolina 27710, USA
| | | | | | | | | | | |
Collapse
|
41
|
Mair RW, Hoffmann D, Sheth SA, Wong GP, Butler JP, Patz S, Topulos GP, Walsworth RL. Reduced xenon diffusion for quantitative lung study--the role of SF(6). NMR IN BIOMEDICINE 2000; 13:229-233. [PMID: 10867701 DOI: 10.1002/1099-1492(200006)13:4<229::aid-nbm637>3.0.co;2-s] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The large diffusion coefficients of gases result in significant spin motion during the application of gradient pulses that typically last a few milliseconds in most NMR experiments. In restricted environments, such as the lung, this rapid gas diffusion can lead to violations of the narrow pulse approximation, a basic assumption of the standard Stejskal-Tanner NMR method of diffusion measurement. We therefore investigated the effect of a common, biologically inert buffer gas, sulfur hexafluoride (SF(6)), on (129)Xe NMR and diffusion. We found that the contribution of SF(6) to (129)Xe T(1) relaxation in a 1:1 xenon/oxygen mixture is negligible up to 2 bar of SF(6) at standard temperature. We also measured the contribution of SF(6) gas to (129)Xe T(2) relaxation, and found it to scale inversely with pressure, with this contribution approximately equal to 1 s for 1 bar SF(6) pressure and standard temperature. Finally, we found the coefficient of (129)Xe diffusion through SF(6) to be approximately 4.6 x 10(-6) m(2)s(-1) for 1 bar pressure of SF(6) and standard temperature, which is only 1.2 times smaller than the (129)Xe self diffusion coefficient for 1 bar (129)Xe pressure and standard temperature. From these measurements we conclude that SF(6) will not sufficiently reduce (129)Xe diffusion to allow accurate surface-area/volume ratio measurements in human alveoli using time-dependent gas diffusion NMR.
Collapse
Affiliation(s)
- R W Mair
- Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, MS 59, Cambridge, MA 02138, USA.
| | | | | | | | | | | | | | | |
Collapse
|
42
|
Mair RW, Tseng CH, Wong GP, Cory DG, Walsworth RL. Magnetic resonance imaging of convection in laser-polarized xenon. PHYSICAL REVIEW. E, STATISTICAL PHYSICS, PLASMAS, FLUIDS, AND RELATED INTERDISCIPLINARY TOPICS 2000; 61:2741-2748. [PMID: 11046596 DOI: 10.1103/physreve.61.2741] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/1999] [Indexed: 05/23/2023]
Abstract
We demonstrate nuclear magnetic resonance (NMR) imaging of the flow and diffusion of laser-polarized xenon (129Xe) gas undergoing convection above evaporating laser-polarized liquid xenon. The large xenon NMR signal provided by the laser-polarization technique allows more rapid imaging than one can achieve with thermally polarized gas-liquid systems, permitting shorter time-scale events such as rapid gas flow and gas-liquid dynamics to be observed. Two-dimensional velocity-encoded imaging shows convective gas flow above the evaporating liquid xenon, and also permits the measurement of enhanced gas diffusion near regions of large velocity variation.
Collapse
Affiliation(s)
- R W Mair
- Harvard-Smithsonian Center for Astrophysics, Cambridge, Massachusetts 02138, USA
| | | | | | | | | |
Collapse
|
43
|
Wong GP, Tseng CH, Pomeroy VR, Mair RW, Hinton DP, Hoffmann D, Stoner RE, Hersman FW, Cory DG, Walsworth RL. A system for low field imaging of laser-polarized noble gas. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 1999; 141:217-27. [PMID: 10579945 DOI: 10.1006/jmre.1999.1904] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
We describe a device for performing MRI with laser-polarized noble gas at low magnetic fields (<50 G). The system is robust, portable, inexpensive, and provides gas-phase imaging resolution comparable to that of high field clinical instruments. At 20.6 G, we have imaged laser-polarized (3)He (Larmor frequency of 67 kHz) in both sealed glass cells and excised rat lungs, using approximately 0.1 G/cm gradients to achieve approximately 1 mm(2) resolution. In addition, we measured (3)He T(2)(*) times greater than 100 ms in excised rat lungs, which is roughly 20 times longer than typical values observed at high ( approximately 2 T) fields. We include a discussion of the practical considerations for working at low magnetic fields and conclude with evidence of radiation damping in this system.
Collapse
Affiliation(s)
- G P Wong
- Harvard-Smithsonian Center for Astrophysics, Cambridge, Massachusetts 02138, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Mair RW, Wong GP, Hoffmann D, Hurlimann MD, Patz S, Schwartz LM, Walsworth RL. Probing porous media with gas diffusion NMR. PHYSICAL REVIEW LETTERS 1999; 83:3324-3327. [PMID: 11543587 DOI: 10.1103/physrevlett.83.3324] [Citation(s) in RCA: 79] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
We show that gas diffusion nuclear magnetic resonance (GD-NMR) provides a powerful technique for probing the structure of porous media. In random packs of glass beads, using both laser-polarized and thermally polarized xenon gas, we find that GD-NMR can accurately measure the pore space surface-area-to-volume ratio, S/V rho, and the tortuosity, alpha (the latter quantity being directly related to the system's transport properties). We also show that GD-NMR provides a good measure of the tortuosity of sandstone and complex carbonate rocks.
Collapse
Affiliation(s)
- R W Mair
- Harvard-Smithsonian Center for Astrophysics, Cambridge, Massachusetts 02138, USA
| | | | | | | | | | | | | |
Collapse
|
45
|
Peled S, Tseng CH, Sodickson AA, Mair RW, Walsworth RL, Cory DG. Single-shot diffusion measurement in laser-polarized Gas. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 1999; 140:320-4. [PMID: 10497039 PMCID: PMC2856658 DOI: 10.1006/jmre.1999.1850] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
A single-shot pulsed gradient stimulated echo sequence is introduced to address the challenges of diffusion measurements of laser polarized 3He and 129Xe gas. Laser polarization enhances the NMR sensitivity of these noble gases by >10(3), but creates an unstable, nonthermal polarization that is not readily renewable. A new method is presented which permits parallel acquisition of the several measurements required to determine a diffusive attenuation curve. The NMR characterization of a sample's diffusion behavior can be accomplished in a single measurement, using only a single polarization step. As a demonstration, the diffusion coefficient of a sample of laser-polarized 129Xe gas is measured via this method.
Collapse
Affiliation(s)
- S Peled
- Department of Nuclear Engineering, Massachusetts Institute of Technology, 150 Albany Street, Cambridge, Massachusetts 02139, USA
| | | | | | | | | | | |
Collapse
|
46
|
Chen XJ, Möller HE, Chawla MS, Cofer GP, Driehuys B, Hedlund LW, Johnson GA. Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part I: diffusion coefficient. Magn Reson Med 1999; 42:721-8. [PMID: 10502761 DOI: 10.1002/(sici)1522-2594(199910)42:4<721::aid-mrm14>3.0.co;2-d] [Citation(s) in RCA: 156] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In imaging of hyperpolarized noble gases, a knowledge of the diffusion coefficient (D) is important both as a contrast mechanism and in the design of pulse sequences. We have made diffusion coefficient maps of both hyperpolarized (3)He and (129)Xe in guinea pig lungs. Along the length of the trachea, (3)He D values were on average 2.4 cm(2)/sec, closely reproducing calculated values for free gas (2.05 cm(2)/sec). The (3)He D values measured perpendicular to the length of the trachea were approximately a factor of two less, indicating restriction to diffusion. Further evidence of restricted diffusion was seen in the distal pulmonary airspaces as the average (3)He D was 0.16 cm(2)/sec. An additional cause for the smaller (3)He D in the lung was due to the presence of air, which is composed of heavier and larger gases. The (129)Xe results show similar trends, with the trachea D averaging 0.068 cm(2)/sec and the lung D averaging 0.021 cm(2)/sec. Magn Reson Med 42:721-728, 1999.
Collapse
Affiliation(s)
- X J Chen
- Center for In Vivo Microscopy, Duke University Medical Center, Durham, North Carolina 27710, USA
| | | | | | | | | | | | | |
Collapse
|
47
|
Albert MS, Kacher DF, Balamore D, Venkatesh AK, Jolesz FA. T(1) of (129)Xe in blood and the role of oxygenation. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 1999; 140:264-273. [PMID: 10479571 DOI: 10.1006/jmre.1999.1836] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
In previous experiments by the authors, in which hyperpolarized (129)Xe was dissolved in fresh blood samples, the T(1) was found to be strongly dependent on the oxygenation level, the values increasing with oxygenation: T(1) was about 4 s in deoxygenated samples and about 13 s in oxygenated samples. C. H. Tseng et al. (1997, J. Magn. Reson. 126, 79-86), on the other hand, recently reported extremely long T(1) values using hyperpolarized (129)Xe to create a "blood foam" and found that oxygenation decreased T(1). In their experiments, the continual and rapid exchange of hyperpolarized (129)Xe between the gas phase (within blood-foam bubbles) and the dissolved phase (in the skin of the bubbles) necessitated a complicated analysis to extract the effective blood T(1). In the present study, the complications of hyperpolarized (129)Xe exchange dynamics have been avoided by using thermally polarized (129)Xe dissolved in whole blood and in suspensions of lysed red blood cells (RBC). During T(1) measurements in whole blood, the samples were gently and continuously agitated, for the entire course of the experiment, to avert sedimentation. Oxygenation was found to markedly increase the T(1) of (129)Xe in blood, as originally measured, and it shifts the RBC resonance to a higher frequency. Carbon monoxide has a similar but somewhat stronger effect.
Collapse
Affiliation(s)
- M S Albert
- Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts 02115, USA.
| | | | | | | | | |
Collapse
|
48
|
Kober F, Koenigsberg B, Belle V, Viallon M, Leviel JL, Delon A, Ziegler A, Décorps M. NMR imaging of thermally polarized helium-3 gas. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 1999; 138:308-312. [PMID: 10341135 DOI: 10.1006/jmre.1999.1756] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
It is shown that thermally polarized 3He gas can be used to measure important physical parameters and to design, test, and tune imaging sequences. The bulk values of T1, T2, and the diffusion coefficient were measured in a glass cell containing a mixture of helium-3 (0.8 bar) and oxygen (0.2 bar). They were found to be T1 = 7 s, T2 = 2.4 s, and D = 1.6 cm2 s(-1). The relaxation times T2* and T1 and the apparent diffusion coefficient of thermally polarized helium-3 gas were measured in the rat lung, and these parameters were used to design a helium-3 optimized multi-spin-echo sequence which was shown to increase the signal-to-noise ratio sufficiently to obtain the first NMR-images of thermally polarized helium-3 in the rat lung.
Collapse
Affiliation(s)
- F Kober
- INSERM U-438, Université Joseph Fourier, LRC CEA, LCHU, Pavillon B, Grenoble, Cedex 9, 38043, France
| | | | | | | | | | | | | | | |
Collapse
|