1
|
Hopstock K, Perraud V, Dalton AB, Barletta B, Meinardi S, Weltman RM, Mirkhanian MA, Rakosi KJ, Blake DR, Edwards RD, Nizkorodov SA. Chemical Analysis of Exhaled Vape Emissions: Unraveling the Complexities of Humectant Fragmentation in a Human Trial Study. Chem Res Toxicol 2024; 37:1000-1010. [PMID: 38769630 PMCID: PMC11187636 DOI: 10.1021/acs.chemrestox.4c00088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Revised: 05/01/2024] [Accepted: 05/08/2024] [Indexed: 05/22/2024]
Abstract
Electronic cigarette smoking (or vaping) is on the rise, presenting questions about the effects of secondhand exposure. The chemical composition of vape emissions was examined in the exhaled breath of eight human volunteers with the high chemical specificity of complementary online and offline techniques. Our study is the first to take multiple exhaled puff measurements from human participants and compare volatile organic compound (VOC) concentrations between two commonly used methods, proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS) and gas chromatography (GC). Five flavor profile groups were selected for this study, but flavor compounds were not observed as the main contributors to the PTR-ToF-MS signal. Instead, the PTR-ToF-MS mass spectra were overwhelmed by e-liquid thermal decomposition and fragmentation products, which masked other observations regarding flavorings and other potentially toxic species associated with secondhand vape exposure. Compared to the PTR-ToF-MS, GC measurements reported significantly different VOC concentrations, usually below those from PTR-ToF-MS. Consequently, PTR-ToF-MS mass spectra should be interpreted with caution when reporting quantitative results in vaping studies, such as doses of inhaled VOCs. Nevertheless, the online PTR-ToF-MS analysis can provide valuable qualitative information by comparing relative VOCs in back-to-back trials. For example, by comparing the mass spectra of exhaled air with those of direct puffs, we can conclude that harmful VOCs present in the vape emissions are largely absorbed by the participants, including large fractions of nicotine.
Collapse
Affiliation(s)
- Katherine
S. Hopstock
- Department
of Chemistry, University of California, Irvine, California 92697, United States
| | - Véronique Perraud
- Department
of Chemistry, University of California, Irvine, California 92697, United States
| | - Avery B. Dalton
- Department
of Chemistry, University of California, Irvine, California 92697, United States
| | - Barbara Barletta
- Department
of Chemistry, University of California, Irvine, California 92697, United States
| | - Simone Meinardi
- Department
of Chemistry, University of California, Irvine, California 92697, United States
| | - Robert M. Weltman
- Program
in Public Health, University of California, Irvine, California 92697, United States
| | - Megan A. Mirkhanian
- Program
in Public Health, University of California, Irvine, California 92697, United States
| | - Krisztina J. Rakosi
- Department
of Chemistry, University of California, Irvine, California 92697, United States
| | - Donald R. Blake
- Department
of Chemistry, University of California, Irvine, California 92697, United States
| | - Rufus D. Edwards
- Program
in Public Health, University of California, Irvine, California 92697, United States
| | - Sergey A. Nizkorodov
- Department
of Chemistry, University of California, Irvine, California 92697, United States
| |
Collapse
|
2
|
Singh S, S S, Varma P, Sreelekha G, Adak C, Shukla RP, Kamble VB. Metal oxide-based gas sensor array for VOCs determination in complex mixtures using machine learning. Mikrochim Acta 2024; 191:196. [PMID: 38478125 PMCID: PMC10937778 DOI: 10.1007/s00604-024-06258-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Accepted: 02/12/2024] [Indexed: 03/17/2024]
Abstract
Detection of volatile organic compounds (VOCs) from the breath is becoming a viable route for the early detection of diseases non-invasively. This paper presents a sensor array of 3 component metal oxides that give maximal cross-sensitivity and can successfully use machine learning methods to identify four distinct VOCs in a mixture. The metal oxide sensor array comprises NiO-Au (ohmic), CuO-Au (Schottky), and ZnO-Au (Schottky) sensors made by the DC reactive sputtering method and having a film thickness of 80-100 nm. The NiO and CuO films have ultrafine particle sizes of < 50 nm and rough surface texture, while ZnO films consist of nanoscale platelets. This array was subjected to various VOC concentrations, including ethanol, acetone, toluene, and chloroform, one by one and in a pair/mix of gases. Thus, the response values show severe interference and departure from commonly observed power law behavior. The dataset obtained from individual gases and their mixtures were analyzed using multiple machine learning algorithms, such as Random Forest (RF), K-Nearest Neighbor (KNN), Decision Tree, Linear Regression, Logistic Regression, Naive Bayes, Linear Discriminant Analysis, Artificial Neural Network, and Support Vector Machine. KNN and RF have shown more than 99% accuracy in classifying different varying chemicals in the gas mixtures. In regression analysis, KNN has delivered the best results with an R2 value of more than 0.99 and LOD of 0.012 ppm, 0.015 ppm, 0.014 ppm, and 0.025 ppm for predicting the concentrations of acetone, toluene, ethanol, and chloroform, respectively, in complex mixtures. Therefore, it is demonstrated that the array utilizing the provided algorithms can classify and predict the concentrations of the four gases simultaneously for disease diagnosis and treatment monitoring.
Collapse
Affiliation(s)
- Shivam Singh
- School of Physics, Indian Institute of Science Education and Research, Thiruvananthapuram, Kerala, 695551, India
| | - Sajana S
- School of Physics, Indian Institute of Science Education and Research, Thiruvananthapuram, Kerala, 695551, India
| | - Poornima Varma
- Dept. of CSE, Indian Institute of Information Technology, Lucknow, Uttar Pradesh, 226002, India
| | - Gajje Sreelekha
- Dept. of CSE, Indian Institute of Technology, Patna, Bihar, 801106, India
| | - Chandranath Adak
- Dept. of CSE, Indian Institute of Technology, Patna, Bihar, 801106, India.
| | - Rajendra P Shukla
- BIOS Lab-On-a-Chip Group, MESA+ Institute for Nanotechnology, Max Planck Center for Complex Fluid Dynamics, University of Twente, P.O. Box 217, 7500, Enschede, The Netherlands.
| | - Vinayak B Kamble
- School of Physics, Indian Institute of Science Education and Research, Thiruvananthapuram, Kerala, 695551, India.
| |
Collapse
|
3
|
Kemnitz N, Fuchs P, Remy R, Ruehrmund L, Bartels J, Klemenz AC, Trefz P, Miekisch W, Schubert JK, Sukul P. Effects of Contagious Respiratory Pathogens on Breath Biomarkers. Antioxidants (Basel) 2024; 13:172. [PMID: 38397770 PMCID: PMC10886173 DOI: 10.3390/antiox13020172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 01/17/2024] [Accepted: 01/23/2024] [Indexed: 02/25/2024] Open
Abstract
Due to their immediate exhalation after generation at the cellular/microbiome levels, exhaled volatile organic compounds (VOCs) may provide real-time information on pathophysiological mechanisms and the host response to infection. In recent years, the metabolic profiling of the most frequent respiratory infections has gained interest as it holds potential for the early, non-invasive detection of pathogens and the monitoring of disease progression and the response to therapy. Using previously unpublished data, randomly selected individuals from a COVID-19 test center were included in the study. Based on multiplex PCR results (non-SARS-CoV-2 respiratory pathogens), the breath profiles of 479 subjects with the presence or absence of flu-like symptoms were obtained using proton-transfer-reaction time-of-flight mass spectrometry. Among 223 individuals, one respiratory pathogen was detected in 171 cases, and more than one pathogen in 52 cases. A total of 256 subjects had negative PCR test results and had no symptoms. The exhaled VOC profiles were affected by the presence of Haemophilus influenzae, Streptococcus pneumoniae, and Rhinovirus. The endogenous ketone, short-chain fatty acid, organosulfur, aldehyde, and terpene concentrations changed, but only a few compounds exhibited concentration changes above inter-individual physiological variations. Based on the VOC origins, the observed concentration changes may be attributed to oxidative stress and antioxidative defense, energy metabolism, systemic microbial immune homeostasis, and inflammation. In contrast to previous studies with pre-selected patient groups, the results of this study demonstrate the broad inter-individual variations in VOC profiles in real-life screening conditions. As no unique infection markers exist, only concentration changes clearly above the mentioned variations can be regarded as indicative of infection or colonization.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | - Pritam Sukul
- Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Department of Anaesthesiology, Intensive Care Medicine and Pain Therapy, University Medicine Rostock, 18057 Rostock, Germany
| |
Collapse
|
4
|
Li Y, Wei X, Zhou Y, Wang J, You R. Research progress of electronic nose technology in exhaled breath disease analysis. MICROSYSTEMS & NANOENGINEERING 2023; 9:129. [PMID: 37829158 PMCID: PMC10564766 DOI: 10.1038/s41378-023-00594-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 08/16/2023] [Accepted: 08/17/2023] [Indexed: 10/14/2023]
Abstract
Exhaled breath analysis has attracted considerable attention as a noninvasive and portable health diagnosis method due to numerous advantages, such as convenience, safety, simplicity, and avoidance of discomfort. Based on many studies, exhaled breath analysis is a promising medical detection technology capable of diagnosing different diseases by analyzing the concentration, type and other characteristics of specific gases. In the existing gas analysis technology, the electronic nose (eNose) analysis method has great advantages of high sensitivity, rapid response, real-time monitoring, ease of use and portability. Herein, this review is intended to provide an overview of the application of human exhaled breath components in disease diagnosis, existing breath testing technologies and the development and research status of electronic nose technology. In the electronic nose technology section, the three aspects of sensors, algorithms and existing systems are summarized in detail. Moreover, the related challenges and limitations involved in the abovementioned technologies are also discussed. Finally, the conclusion and perspective of eNose technology are presented.
Collapse
Affiliation(s)
- Ying Li
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
- Laboratory of Intelligent Microsystems, Beijing Information Science and Technology University, Beijing, 100192 China
| | - Xiangyang Wei
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
- Laboratory of Intelligent Microsystems, Beijing Information Science and Technology University, Beijing, 100192 China
| | - Yumeng Zhou
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
| | - Jing Wang
- School of Electronics and Information Engineering, Changchun University of Science and Technology, Changchun, 130022 China
| | - Rui You
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
- Laboratory of Intelligent Microsystems, Beijing Information Science and Technology University, Beijing, 100192 China
| |
Collapse
|
5
|
Sukul P, Richter A, Junghanss C, Schubert JK, Miekisch W. Origin of breath isoprene in humans is revealed via multi-omic investigations. Commun Biol 2023; 6:999. [PMID: 37777700 PMCID: PMC10542801 DOI: 10.1038/s42003-023-05384-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 09/22/2023] [Indexed: 10/02/2023] Open
Abstract
Plants, animals and humans metabolically produce volatile isoprene (C5H8). Humans continuously exhale isoprene and exhaled concentrations differ under various physio-metabolic and pathophysiological conditions. Yet unknown metabolic origin hinders isoprene to reach clinical practice as a biomarker. Screening 2000 individuals from consecutive mass-spectrometric studies, we herein identify five healthy German adults without exhaled isoprene. Whole exome sequencing in these adults reveals only one shared homozygous (European prevalence: <1%) IDI2 stop-gain mutation, which causes losses of enzyme active site and Mg2+-cofactor binding sites. Consequently, the conversion of isopentenyl diphosphate to dimethylallyl diphosphate (DMAPP) as part of the cholesterol metabolism is prevented in these adults. Targeted sequencing depicts that the IDI2 rs1044261 variant (p.Trp144Stop) is heterozygous in isoprene deficient blood-relatives and absent in unrelated isoprene normal adults. Wild-type IDI1 and cholesterol metabolism related serological parameters are normal in all adults. IDI2 determines isoprene production as only DMAPP sources isoprene and unlike plants, humans lack isoprene synthase and its enzyme homologue. Human IDI2 is expressed only in skeletal-myocellular peroxisomes and instant spikes in isoprene exhalation during muscle activity underpins its origin from muscular lipolytic cholesterol metabolism. Our findings translate isoprene as a clinically interpretable breath biomarker towards potential applications in human medicine.
Collapse
Affiliation(s)
- Pritam Sukul
- Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Dept. of Anesthesiology, Intensive Care Medicine and Pain Therapy, University Medicine Rostock, Schillingallee 35, 18057, Rostock, Germany.
| | - Anna Richter
- Department of Medicine, Clinic III - Hematology, Oncology, Palliative Medicine, Rostock University Medical Center, Ernst-Heydemann-Strasse 6, 18057, Rostock, Germany
| | - Christian Junghanss
- Department of Medicine, Clinic III - Hematology, Oncology, Palliative Medicine, Rostock University Medical Center, Ernst-Heydemann-Strasse 6, 18057, Rostock, Germany
| | - Jochen K Schubert
- Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Dept. of Anesthesiology, Intensive Care Medicine and Pain Therapy, University Medicine Rostock, Schillingallee 35, 18057, Rostock, Germany
| | - Wolfram Miekisch
- Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Dept. of Anesthesiology, Intensive Care Medicine and Pain Therapy, University Medicine Rostock, Schillingallee 35, 18057, Rostock, Germany
| |
Collapse
|
6
|
Zhang X, Frankevich V, Ding J, Ma Y, Chingin K, Chen H. Direct mass spectrometry analysis of exhaled human breath in real-time. MASS SPECTROMETRY REVIEWS 2023. [PMID: 37565588 DOI: 10.1002/mas.21855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 05/02/2022] [Accepted: 10/01/2022] [Indexed: 08/12/2023]
Abstract
The molecular composition of exhaled human breath can reflect various physiological and pathological conditions. Considerable progress has been achieved over the past decade in real-time analysis of exhaled human breath using direct mass spectrometry methods, including selected ion flow tube mass spectrometry, proton transfer reaction mass spectrometry, extractive electrospray ionization mass spectrometry, secondary electrospray ionization mass spectrometry, acetone-assisted negative photoionization mass spectrometry, atmospheric pressure photoionization mass spectrometry, and low-pressure photoionization mass spectrometry. Here, recent developments in direct mass spectrometry analysis of exhaled human breath are reviewed with regard to analytical performance (chemical sensitivity, selectivity, quantitative capabilities) and applications of the developed methods in disease diagnosis, targeted molecular detection, and real-time metabolic monitoring.
Collapse
Affiliation(s)
- Xiaoping Zhang
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, People's Republic of China
| | - Vladimir Frankevich
- National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I. Kulakov of Ministry of Healthcare of Russian Federation, Moscow, Russian Federation
| | - Jianhua Ding
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, People's Republic of China
| | - Yuanyuan Ma
- Department of GCP, Shanghai Public Health Clinical Center, Shanghai, China
| | - Konstantin Chingin
- School of Pharmacy, Jiangxi University of Chinese Medicine, Nanchang, People's Republic of China
| | - Huanwen Chen
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, People's Republic of China
- School of Pharmacy, Jiangxi University of Chinese Medicine, Nanchang, People's Republic of China
| |
Collapse
|
7
|
Geng X, Zhang K, Li H, Da Yong Chen D. Online mass spectrometry of exhaled breath with a modified ambient ion source. Talanta 2023; 255:124254. [PMID: 36634427 DOI: 10.1016/j.talanta.2023.124254] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 01/03/2023] [Accepted: 01/05/2023] [Indexed: 01/07/2023]
Abstract
Exhaled breath (EB) may contain metabolites that are closely related to human health conditions. Real time analysis of EB is important to study its true composition, however, it has been difficult. A robust ambient ionization mass spectrometry method using a modified direct analysis in real time (DART) ion source was developed for the online analysis of breath volatiles. The modified DART ion source can provide a confined region for direct sampling, rapid transmission and efficient ionization of exhaled breath. With different sampling methods, offline analysis and near real-time evaluation of exhaled breath were also achieved, and their unique molecular features were characterized. High resolution MS data aided the putative metabolite identification in breath samples, resulting in hundreds of volatile organic compounds being identified in the exhalome. The method was sensitive enough to be used for monitoring the breath feature changes after taking different food and over-the-counter medicine. Quantification was performed for pyridine and valeric acid with fasting and after ingesting different food. The developed method is fast, simple, versatile, and potentially useful for evaluating the true state of human exhaled breath.
Collapse
Affiliation(s)
- Xin Geng
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China
| | - Kai Zhang
- Department of Geriatric Gastroenterology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, 250021, China; Department of Gastroenterology, Dongying People's Hospital, Dongying, Shandong, 257091, China
| | - Hongli Li
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China.
| | - David Da Yong Chen
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, China; Department of Chemistry, University of British Columbia, Vancouver BC, V6T 1Z1, Canada.
| |
Collapse
|
8
|
Xu W, Zou X, Ding Y, Zhang J, Zheng L, Zuo H, Yang M, Zhou Q, Liu Z, Ge D, Zhang Q, Song W, Huang C, Shen C, Chu Y. Rapid screen for ventilator associated pneumonia using exhaled volatile organic compounds. Talanta 2022. [DOI: 10.1016/j.talanta.2022.124069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
9
|
Jakšić M, Mihajlović A, Vujić D, Giannoukos S, Brkić B. Membrane inlet mass spectrometry method for food intake impact assessment on specific volatile organic compounds in exhaled breath. Anal Bioanal Chem 2022; 414:6077-6091. [PMID: 35727330 PMCID: PMC9314300 DOI: 10.1007/s00216-022-04168-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 05/24/2022] [Accepted: 06/07/2022] [Indexed: 11/30/2022]
Abstract
This research work describes the development of a novel bioanalytical method for the assessment of food impact on selected exhaled breath volatile organic compounds (VOCs) using a fast and portable screening VOC prototype sensor based on membrane inlet mass spectrometry (MIMS). Method and sensor prototype functionality was verified by obtaining good response times, linearity in the examined concentration ranges, and sensitivity and repeatability for several breath VOCs—acetone, ethanol, n-pentane, and isoprene. A new VOC sensor prototype was also proven to be sensitive enough for selected breath VOC quantification with limits of detection at low part per billion (ppb) levels—5 ppb for n-pentane, 10 ppb for acetone and ethanol, and 25 ppb for isoprene. Food impact assessment was accomplished by tracking the levels of acetone, ethanol, n-pentane, and isoprene in exhaled breath samples collected from 50 healthy participants before the meal and 60 min and 120 min after the meal. For acetone, isoprene, and n-pentane, a larger impact was noticed 120 min after the meal, while for ethanol, it was after 60 min. Obtained VOC levels were in the expected concentration ranges. Mean values at all time points were ~ 500–900 ppb for acetone and ~ 400–600 ppb for ethanol. Most of the results for n-pentane were below 5 ppb, but the mean value for those which were detected was ~ 30 ppb. Along with samples, data about participants’ lifestyle were collected via a short questionnaire, which were compared against obtained VOC levels in order to reveal some significant correlations between habits of participants and their breath VOC levels.
Collapse
Affiliation(s)
- Milena Jakšić
- BioSense Institute, University of Novi Sad, Dr Zorana Djindjića 1, 21000, Novi Sad, Serbia.
| | - Andrea Mihajlović
- BioSense Institute, University of Novi Sad, Dr Zorana Djindjića 1, 21000, Novi Sad, Serbia
| | - Djordje Vujić
- BioSense Institute, University of Novi Sad, Dr Zorana Djindjića 1, 21000, Novi Sad, Serbia
| | - Stamatios Giannoukos
- Department of Chemistry and Applied Biosciences, ETH Zurich, HCI D 317, Vladimir-Prelog-Weg 3, CH-8093, Zurich, Switzerland
| | - Boris Brkić
- BioSense Institute, University of Novi Sad, Dr Zorana Djindjića 1, 21000, Novi Sad, Serbia.
| |
Collapse
|
10
|
Alrowaili ZA, Elsayed HA, Ahmed AM, Taha TA, Mehaney A. Simple, efficient and accurate method toward the monitoring of ethyl butanoate traces. OPTICAL AND QUANTUM ELECTRONICS 2022; 54:126. [PMID: 35095173 PMCID: PMC8783197 DOI: 10.1007/s11082-021-03497-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 12/21/2021] [Indexed: 06/14/2023]
Abstract
We introduce in this research a simple, accurate, safe, and efficient design for the detection of ethyl butanoate that be present in the dry exhaled breath. In particular, the presence of ethyl butanoate in the dry exhaled breath could be utilized as a platform for the diagnosing of COVID 19. The main idea of this theoretical investigation is based on the inclusion of a cavity layer between a thin layer of Au and the well-known one-dimension photonic crystals. Accordingly, the cavity layer is filled with dry exhaled breath. The numerical results are investigated in the vicinity of the Drude model and transfer matrix method. The investigated results show the appearance of Tamm plasmon resonance in the reflectance spectrum of our design through the IR region. Such resonant mode provides very high sensitivity with the change in the concentration of ethyl butanoate. We have examined the performance of the proposed sensor by calculating its sensitivity, detection limit, detection accuracy, quality factor and figure of merit. The designed sensor could receive sensitivity of 0.3 nm/ppm or 260,486 nm/RIU, resolution of 7 ppm and quality factor of 969.
Collapse
Affiliation(s)
- Z. A. Alrowaili
- Physics Department, College of Science, Jouf University, P.O. Box: 2014, Sakaka, Saudi Arabia
| | - Hussein A. Elsayed
- TH-PPM Group, Physics Department, Faculty of Science, Beni-Suef University, Beni-Suef, 62512 Egypt
| | - Ashour M. Ahmed
- Physics Department, Faculty of Science, Beni-Suef University, Beni-Suef, 62512 Egypt
| | - T. A. Taha
- Physics Department, College of Science, Jouf University, P.O. Box: 2014, Sakaka, Saudi Arabia
| | - Ahmed Mehaney
- TH-PPM Group, Physics Department, Faculty of Science, Beni-Suef University, Beni-Suef, 62512 Egypt
| |
Collapse
|
11
|
Roquencourt C, Grassin-Delyle S, Thévenot EA. ptairMS: real-time processing and analysis of PTR-TOF-MS data for biomarker discovery in exhaled breath. Bioinformatics 2022; 38:1930-1937. [PMID: 35043937 PMCID: PMC8963316 DOI: 10.1093/bioinformatics/btac031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 12/24/2021] [Accepted: 01/16/2022] [Indexed: 11/14/2022] Open
Abstract
Motivation Analysis of volatile organic compounds (VOCs) in exhaled breath by proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS) is of increasing interest for real-time, non-invasive diagnosis, phenotyping and therapeutic drug monitoring in the clinics. However, there is currently a lack of methods and software tools for the processing of PTR-TOF-MS data from cohorts and suited for biomarker discovery studies. Results We developed a comprehensive suite of algorithms that process raw data from patient acquisitions and generate the table of feature intensities. Notably, we included an innovative two-dimensional peak deconvolution model based on penalized splines signal regression for accurate estimation of the temporal profile and feature quantification, as well as a method to specifically select the VOCs from exhaled breath. The workflow was implemented as the ptairMS software, which contains a graphical interface to facilitate cohort management and data analysis. The approach was validated on both simulated and experimental datasets, and we showed that the sensitivity and specificity of the VOC detection reached 99% and 98.4%, respectively, and that the error of quantification was below 8.1% for concentrations down to 19 ppb. Availability and implementation The ptairMS software is publicly available as an R package on Bioconductor (doi: 10.18129/B9.bioc.ptairMS), as well as its companion experiment package ptairData (doi: 10.18129/B9.bioc.ptairData). Supplementary information Supplementary data are available at Bioinformatics online.
Collapse
Affiliation(s)
- Camille Roquencourt
- CEA, LIST, Laboratoire Sciences des Données et de la Décision, F-91191 Gif-Sur-Yvette, France
| | - Stanislas Grassin-Delyle
- Hôpital Foch, Exhalomics, Département des maladies des voies respiratoires, Suresnes, France
- Université Paris-Saclay, UVSQ, INSERM, Infection et inflammation, Département de Biotechnologie de la Santé, Montigny le Bretonneux, France
- FHU SEPSIS (Saclay and Paris Seine Nord Endeavour to PerSonalize Interventions for Sepsis)
| | - Etienne A Thévenot
- Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (MTS), MetaboHUB, F-91191 Gif sur Yvette, France
| |
Collapse
|
12
|
Zhang J, Lei C, Liang T, Liu R, Zhao Z, Qi L, Ghaffar A, Xiong J. Acetone Sensor Based on FAIMS-MEMS. MICROMACHINES 2021; 12:1531. [PMID: 34945383 PMCID: PMC8703384 DOI: 10.3390/mi12121531] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/02/2021] [Accepted: 12/05/2021] [Indexed: 12/02/2022]
Abstract
In this paper, to address the problems of large blood draws, long testing times, and the inability to achieve dynamic detection of invasive testing for diabetes, stemming from the principle that type 1 diabetic patients exhale significantly higher levels of acetone than normal people, a FAIMS-MEMS gas sensor was designed to detect acetone, which utilizes the characteristics of high sensitivity, fast response, and non-invasive operation. It is prepared by MEMS processes, such as photolithography, etching, and sputtering, its specific dimensions are 4000 μm in length, 3000 μm in width and 800 μm in height and the related test system was built to detect acetone gas. The test results show that when acetone below 0.8 ppm is introduced, the voltage value detected by the sensor basically does not change, while when acetone gas exceeds 1.8 ppm, the voltage value detected by the sensor increases significantly. The detection accuracy of the sensor prepared by this method is about 0.02 ppm/mV, and the voltage change can reach 1 V with a response time of 3 s and a recovery time of 4 s when tested under 20 ppm acetone environment; this has good repeatability and stability, and has great prospects in the field of non-invasive detection of type 1 diabetes.
Collapse
Affiliation(s)
- Junna Zhang
- State Key Laboratory of Dynamic Measurement Technology, North University of China, Taiyuan 030051, China; (J.Z.); (Z.Z.); (J.X.)
| | - Cheng Lei
- State Key Laboratory of Dynamic Measurement Technology, North University of China, Taiyuan 030051, China; (J.Z.); (Z.Z.); (J.X.)
| | - Ting Liang
- State Key Laboratory of Dynamic Measurement Technology, North University of China, Taiyuan 030051, China; (J.Z.); (Z.Z.); (J.X.)
| | - Ruifang Liu
- State Key Laboratory of Bioelectronics, Southeast University, Nanjing 210096, China;
| | - Zhujie Zhao
- State Key Laboratory of Dynamic Measurement Technology, North University of China, Taiyuan 030051, China; (J.Z.); (Z.Z.); (J.X.)
| | - Lei Qi
- North Automatic Control Technology Institute, Taiyuan 030006, China;
| | - Abdul Ghaffar
- State Key Laboratory of Geomechanics and Geotechnical Engineering, Institute of Rock and Soil Mechanics, Chinese Academy of Sciences, Wuhan 430071, China;
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jijun Xiong
- State Key Laboratory of Dynamic Measurement Technology, North University of China, Taiyuan 030051, China; (J.Z.); (Z.Z.); (J.X.)
| |
Collapse
|
13
|
Hu B, Ouyang G. In situ solid phase microextraction sampling of analytes from living human objects for mass spectrometry analysis. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116368] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
14
|
Finewax Z, Pagonis D, Claflin MS, Handschy AV, Brown WL, Jenks O, Nault BA, Day DA, Lerner BM, Jimenez JL, Ziemann PJ, de Gouw JA. Quantification and source characterization of volatile organic compounds from exercising and application of chlorine-based cleaning products in a university athletic center. INDOOR AIR 2021; 31:1323-1339. [PMID: 33337567 DOI: 10.1111/ina.12781] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Accepted: 11/30/2020] [Indexed: 05/15/2023]
Abstract
Humans spend approximately 90% of their time indoors, impacting their own air quality through occupancy and activities. Human VOC emissions indoors from exercise are still relatively uncertain, and questions remain about emissions from chlorine-based cleaners. To investigate these and other issues, the ATHLETic center study of Indoor Chemistry (ATHLETIC) campaign was conducted in the weight room of the Dal Ward Athletic Center at the University of Colorado Boulder. Using a Vocus Proton-Transfer-Reaction Time-of-Flight Mass Spectrometer (Vocus PTR-TOF), an Aerodyne Gas Chromatograph (GC), an Iodide-Chemical Ionization Time-of-Flight Mass Spectrometer (I-CIMS), and Picarro cavity ringdown spectrometers, we alternated measurements between the weight room and supply air, allowing for determination of VOC, NH3 , H2 O, and CO2 emission rates per person (emission factors). Human-derived emission factors were higher than previous studies of measuring indoor air quality in rooms with individuals at rest and correlated with increased CO2 emission factors. Emission factors from personal care products (PCPs) were consistent with previous studies and typically decreased throughout the day. In addition, N-chloraldimines were observed in the gas phase after the exercise equipment was cleaned with a dichlor solution. The chloraldimines likely originated from reactions of free amino acids with HOCl on gym surfaces.
Collapse
Affiliation(s)
- Zachary Finewax
- Cooperative Institute for Research in Environmental Sciences (CIRES, University of Colorado, Boulder, CO, USA
- Department of Chemistry, University of Colorado, Boulder, CO, USA
| | - Demetrios Pagonis
- Cooperative Institute for Research in Environmental Sciences (CIRES, University of Colorado, Boulder, CO, USA
- Department of Chemistry, University of Colorado, Boulder, CO, USA
| | | | - Anne V Handschy
- Cooperative Institute for Research in Environmental Sciences (CIRES, University of Colorado, Boulder, CO, USA
- Department of Chemistry, University of Colorado, Boulder, CO, USA
| | - Wyatt L Brown
- Cooperative Institute for Research in Environmental Sciences (CIRES, University of Colorado, Boulder, CO, USA
- Department of Chemistry, University of Colorado, Boulder, CO, USA
| | - Olivia Jenks
- Cooperative Institute for Research in Environmental Sciences (CIRES, University of Colorado, Boulder, CO, USA
- Department of Chemistry, University of Colorado, Boulder, CO, USA
| | - Benjamin A Nault
- Cooperative Institute for Research in Environmental Sciences (CIRES, University of Colorado, Boulder, CO, USA
- Department of Chemistry, University of Colorado, Boulder, CO, USA
| | - Douglas A Day
- Cooperative Institute for Research in Environmental Sciences (CIRES, University of Colorado, Boulder, CO, USA
- Department of Chemistry, University of Colorado, Boulder, CO, USA
| | | | - Jose L Jimenez
- Cooperative Institute for Research in Environmental Sciences (CIRES, University of Colorado, Boulder, CO, USA
- Department of Chemistry, University of Colorado, Boulder, CO, USA
| | - Paul J Ziemann
- Cooperative Institute for Research in Environmental Sciences (CIRES, University of Colorado, Boulder, CO, USA
- Department of Chemistry, University of Colorado, Boulder, CO, USA
| | - Joost A de Gouw
- Cooperative Institute for Research in Environmental Sciences (CIRES, University of Colorado, Boulder, CO, USA
- Department of Chemistry, University of Colorado, Boulder, CO, USA
| |
Collapse
|
15
|
Ghosh C, Leon A, Koshy S, Aloum O, Al-Jabawi Y, Ismail N, Weiss ZF, Koo S. Breath-Based Diagnosis of Infectious Diseases: A Review of the Current Landscape. Clin Lab Med 2021; 41:185-202. [PMID: 34020759 DOI: 10.1016/j.cll.2021.03.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Various analytical methods can be applied to concentrate, separate, and examine trace volatile organic metabolites in the breath, with the potential for noninvasive, rapid, real-time identification of various disease processes, including an array of microbial infections. Although biomarker discovery and validation in microbial infections can be technically challenging, it is an approach that has shown great promise, especially for infections that are particularly difficult to identify with standard culture and molecular amplification-based approaches. This article discusses the current state of breath analysis for the diagnosis of infectious diseases.
Collapse
Affiliation(s)
- Chiranjit Ghosh
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Armando Leon
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Seena Koshy
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Obadah Aloum
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Yazan Al-Jabawi
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Nour Ismail
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Zoe Freeman Weiss
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA; Division of Infectious Diseases, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Sophia Koo
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA; Dana-Farber Cancer Institute, 450 Brookline Avenue, Boston, MA 02215, USA.
| |
Collapse
|
16
|
Henderson B, Lopes Batista G, Bertinetto CG, Meurs J, Materić D, Bongers CCWG, Allard NAE, Eijsvogels TMH, Holzinger R, Harren FJM, Jansen JJ, Hopman MTE, Cristescu SM. Exhaled Breath Reflects Prolonged Exercise and Statin Use during a Field Campaign. Metabolites 2021; 11:metabo11040192. [PMID: 33805108 PMCID: PMC8064097 DOI: 10.3390/metabo11040192] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 03/16/2021] [Accepted: 03/19/2021] [Indexed: 12/30/2022] Open
Abstract
Volatile organic compounds (VOCs) in exhaled breath provide insights into various metabolic processes and can be used to monitor physiological response to exercise and medication. We integrated and validated in situ a sampling and analysis protocol using proton transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) for exhaled breath research. The approach was demonstrated on a participant cohort comprising users of the cholesterol-lowering drug statins and non-statin users during a field campaign of three days of prolonged and repeated exercise, with no restrictions on food or drink consumption. The effect of prolonged exercise was reflected in the exhaled breath of participants, and relevant VOCs were identified. Most of the VOCs, such as acetone, showed an increase in concentration after the first day of walking and subsequent decrease towards baseline levels prior to walking on the second day. A cluster of short-chain fatty acids including acetic acid, butanoic acid, and propionic acid were identified in exhaled breath as potential indicators of gut microbiota activity relating to exercise and drug use. We have provided novel information regarding the use of breathomics for non-invasive monitoring of changes in human metabolism and especially for the gut microbiome activity in relation to exercise and the use of medication, such as statins.
Collapse
Affiliation(s)
- Ben Henderson
- Department of Molecular and Laser Physics, Institute for Molecules and Materials, Radboud University, 6525 XZ Nijmegen, The Netherlands; (B.H.); (G.L.B.); (J.M.); (D.M.); (F.J.M.H.)
| | - Guilherme Lopes Batista
- Department of Molecular and Laser Physics, Institute for Molecules and Materials, Radboud University, 6525 XZ Nijmegen, The Netherlands; (B.H.); (G.L.B.); (J.M.); (D.M.); (F.J.M.H.)
| | - Carlo G. Bertinetto
- Department of Analytical Chemistry and Chemometrics, Institute for Molecules and Materials, Radboud University, 6525 XZ Nijmegen, The Netherlands; (C.G.B.); (J.J.J.)
| | - Joris Meurs
- Department of Molecular and Laser Physics, Institute for Molecules and Materials, Radboud University, 6525 XZ Nijmegen, The Netherlands; (B.H.); (G.L.B.); (J.M.); (D.M.); (F.J.M.H.)
| | - Dušan Materić
- Department of Molecular and Laser Physics, Institute for Molecules and Materials, Radboud University, 6525 XZ Nijmegen, The Netherlands; (B.H.); (G.L.B.); (J.M.); (D.M.); (F.J.M.H.)
- Institute for Marine and Atmospheric Research, Utrecht University, 3584 CC Utrecht, The Netherlands;
| | - Coen C. W. G. Bongers
- Department of Physiology, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 XZ Nijmegen, The Netherlands; (C.C.W.G.B.); (N.A.E.A.); (T.M.H.E.); (M.T.E.H.)
| | - Neeltje A. E. Allard
- Department of Physiology, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 XZ Nijmegen, The Netherlands; (C.C.W.G.B.); (N.A.E.A.); (T.M.H.E.); (M.T.E.H.)
| | - Thijs M. H. Eijsvogels
- Department of Physiology, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 XZ Nijmegen, The Netherlands; (C.C.W.G.B.); (N.A.E.A.); (T.M.H.E.); (M.T.E.H.)
| | - Rupert Holzinger
- Institute for Marine and Atmospheric Research, Utrecht University, 3584 CC Utrecht, The Netherlands;
| | - Frans J. M. Harren
- Department of Molecular and Laser Physics, Institute for Molecules and Materials, Radboud University, 6525 XZ Nijmegen, The Netherlands; (B.H.); (G.L.B.); (J.M.); (D.M.); (F.J.M.H.)
| | - Jeroen J. Jansen
- Department of Analytical Chemistry and Chemometrics, Institute for Molecules and Materials, Radboud University, 6525 XZ Nijmegen, The Netherlands; (C.G.B.); (J.J.J.)
| | - Maria T. E. Hopman
- Department of Physiology, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 XZ Nijmegen, The Netherlands; (C.C.W.G.B.); (N.A.E.A.); (T.M.H.E.); (M.T.E.H.)
| | - Simona M. Cristescu
- Department of Molecular and Laser Physics, Institute for Molecules and Materials, Radboud University, 6525 XZ Nijmegen, The Netherlands; (B.H.); (G.L.B.); (J.M.); (D.M.); (F.J.M.H.)
- Correspondence:
| |
Collapse
|
17
|
Bellagambi FG, Lomonaco T, Ghimenti S, Biagini D, Fuoco R, Di Francesco F. Determination of peppermint compounds in breath by needle trap micro-extraction coupled with gas chromatography-tandem mass spectrometry. J Breath Res 2020; 15. [PMID: 33238253 DOI: 10.1088/1752-7163/abcdec] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Accepted: 11/25/2020] [Indexed: 01/26/2023]
Abstract
Breath analysis is an alternative approach for disease diagnosis and for monitoring therapy. The lack of standardized procedures for collecting and analysing breath samples currently limits its use in clinical practice. In order to overcome this limitation, the "Peppermint Consortium" was established within the breath community to carry out breath wash-out experiments and define reference values for a panel of compounds contained in the peppermint oil capsule. Here, we present a needle trap micro-extraction technique coupled with gas chromatography and tandem mass spectrometry for a rapid and accurate determination of alpha-pinene, beta-pinene, limonene, eucalyptol, menthofuran, menthone, menthol and menthyl acetate in mixed breath samples. Detection limits between 1 and 20 pptv were observed when 25 mL of a humidified standard gas mixture were loaded into a needle trap device at a flow rate of 10 mL/min. Inter- and intra-day precisions were lower than 15%, thus confirming the reliability of the assay. Our procedure was used to analyse breath samples taken from a nominally healthy volunteer who were invited to swallow a 200 mg capsule of peppermint oil. Six samples were collected at various times within six hours of ingestion. Analyte concentrations were not affected by the sampling mode (i.e. mixed vs. end-tidal fraction), whereas respiratory rate and exhalation flow rate values slightly influenced the concentration of the target compounds in breath samples.
Collapse
Affiliation(s)
- Francesca G Bellagambi
- Institut des Sciences Analytiques, Université Claude Bernard Lyon 1, 5, rue de la Doua, Villeurbanne, FRANCE, 69100, FRANCE
| | - Tommaso Lomonaco
- Department of Chemistry and Industrial Chemistry, Universita degli Studi di Pisa Dipartimento di Chimica e Chimica Industriale, Via G. Moruzzi, 13, Pisa, Tuscany, 56124, ITALY
| | - Silvia Ghimenti
- Department of Chemistry and Industrial Chemistry, University of Pisa, Pisa, Toscana, ITALY
| | - Denise Biagini
- Department of Chemistry and Industrial Chemistry, University of Pisa, Pisa, Toscana, ITALY
| | - Roger Fuoco
- Department of Chemistry and Industrial Chemistry, University of Pisa, Pisa, Toscana, ITALY
| | - Fabio Di Francesco
- Department of Chemistry and Industrial Chemistry, University of Pisa, Pisa, Toscana, ITALY
| |
Collapse
|
18
|
Becker R. Non-invasive cancer detection using volatile biomarkers: Is urine superior to breath? Med Hypotheses 2020; 143:110060. [PMID: 32683218 DOI: 10.1016/j.mehy.2020.110060] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 06/25/2020] [Accepted: 06/27/2020] [Indexed: 12/16/2022]
Abstract
In recent years numerous reports have highlighted the options of chemical breath analysis with regard to non-invasive cancer detection. Certain volatile organic compounds (VOC) supposedly present in higher amounts or in characteristic patterns have been suggested as potential biomarkers. However, so far no clinical application based on a specific set of compounds appears to exist. Numerous reports on the capability of sniffer dogs and sensor arrays or electronic noses to distinguish breath of cancer patients and healthy controls supports the concept of genuine cancer-related volatile profiles. However, the actual compounds responsible for the scent are completely unknown and there is no correlation with the potential biomarkers suggested on basis of chemical trace analysis. It is outlined that specific features connected with the VOC analysis in breath - namely small concentrations of volatiles, interfering background concentrations, considerable sampling effort and sample instability, impracticability regarding routine application - stand in the way of substantial progress. The underlying chemical-analytical challenge can only be met considering the severe susceptibility of VOC determination to these adverse conditions. Therefore, the attention is drawn to the needs for appropriate quality assurance/quality control as the most important feature for the reliable quantification of volatiles present in trace concentration. Consequently, the advantages of urine as an alternative matrix for volatile biomarker search in the context of diagnosing lung and other cancers are outlined with specific focus on quality assurance and practicability in clinical chemistry. The headspace over urine samples as the VOC source allows adapting gas chromatographical procedures well-established in water analysis. Foremost, the selection of urine over breath as non-invasive matrix should provide considerably more resilience to adverse effects during sampling and analysis. The most important advantage of urine over breath is seen in the option to partition, dispense, mix, spike, store, and thus to dispatch taylor-made urine samples on demand for quality control measures. Although it is still open at this point if cancer diagnosis supported by non-invasively sampled VOC profiles will ultimately reach clinical application the advantages of urine over breath should significantly facilitate urgently required steps beyond the current proof-of-concept stage and towards standardisation.
Collapse
Affiliation(s)
- Roland Becker
- Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin, Germany
| |
Collapse
|
19
|
Rosenthal K, Ruszkiewicz DM, Allen H, Lindley MR, Turner MA, Hunsicker E. Breath selection methods for compact mass spectrometry breath analysis. J Breath Res 2019; 13:046013. [PMID: 31342933 DOI: 10.1088/1752-7163/ab34d4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Compact mass spectrometry (CMS) is a versatile and transportable analytical instrument that has the potential to be used in clinical settings to quickly and non-invasively detect a wide range of relevant conditions from breath samples. The purpose of this study is to optimise data preprocessing protocols by three proposed methods of breath sampling, using the CMS. It also lays out a general framework for which data processing methods can be evaluated. METHODS This paper considers data from three previous studies, each using a different breath sampling method. These include a peppermint washout study using continuous breath sampling with a purified air source, an exercise study using continuous breath sampling with an ambient air source, and a single breath sampling study with an ambient air source. For each dataset, different breath selection (data preprocessing) methods were compared and benchmarked according to predictive performance on a validation set and quantitative reliability of m/z bin intensity measurements. RESULTS For both continuous methods, the best breath selection method improved the predictive model compared to no preselection, as measured by the 95% CI range for Youden's index, from 0.68-0.86 to 0.86-0.97 for the exercise study and 0.69-0.82 to 1.00-1.00 for the peppermint study. The reliability of intensity measurements for both datasets (as measured by median relative standard deviation (RSD)), was improved slightly by the best selection method compared to no preselection, from 18% to 14% for the exercise study and 7%-5% for the peppermint study. For the single breath samples, all the models resulted in perfect prediction, with a 95% CI range for Youden's index of 1.00-1.00. The reliability of the proposed method was 38%. CONCLUSION The method of selecting exhaled breath from CMS data can affect the reliability of the measurement and the ability to distinguish between breath samples taken under different conditions. The application of appropriate data processing methods can improve the quality of the data and results obtained from CMS. The methods presented will enable untargeted analysis of breath VOCs using CMS to be performed.
Collapse
Affiliation(s)
- Kerry Rosenthal
- School of Sport, Exercise & Health Sciences, Loughborough University, Loughborough, United Kingdom. Translational Chemical Biology Research Group, United Kingdom
| | | | | | | | | | | |
Collapse
|
20
|
Azim A, Barber C, Dennison P, Riley J, Howarth P. Exhaled volatile organic compounds in adult asthma: a systematic review. Eur Respir J 2019; 54:13993003.00056-2019. [PMID: 31273044 DOI: 10.1183/13993003.00056-2019] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 06/13/2019] [Indexed: 12/11/2022]
Abstract
The search for biomarkers that can guide precision medicine in asthma, particularly those that can be translated to the clinic, has seen recent interest in exhaled volatile organic compounds (VOCs). Given the number of studies reporting "breathomics" findings and its growing integration in clinical trials, we performed a systematic review of the literature to summarise current evidence and understanding of breathomics technology in asthma.A PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses)-oriented systematic search was performed (CRD42017084145) of MEDLINE, Embase and the Cochrane databases to search for any reports that assessed exhaled VOCs in adult asthma patients, using the following terms (asthma AND (volatile organic compounds AND exhaled) OR breathomics).Two authors independently determined the eligibility of 2957 unique records, of which 66 underwent full-text review. Data extraction and risk of bias assessment was performed on the 22 studies deemed to fulfil the search criteria. The studies are described in terms of methodology and the evidence narratively summarised under the following clinical headings: diagnostics, phenotyping, treatment stratification, treatment monitoring and exacerbation prediction/assessment.Our review found that most studies were designed to assess diagnostic potential rather than focus on underlying biology or treatable traits. Results are generally limited by a lack of methodological standardisation and external validation and by insufficiently powered studies, but there is consistency across the literature that exhaled VOCs are sensitive to underlying inflammation. Modern studies are applying robust breath analysis workflows to large multi-centre study designs, which should unlock the full potential of measurement of exhaled volatile organic compounds in airways diseases such as asthma.
Collapse
Affiliation(s)
- Adnan Azim
- Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton, UK .,National Institute for Health Research (NIHR) Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Clair Barber
- Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton, UK.,National Institute for Health Research (NIHR) Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Paddy Dennison
- National Institute for Health Research (NIHR) Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - John Riley
- Galaxy Asthma, GSK, Medicines Research Centre, Stevenage, UK
| | - Peter Howarth
- Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton, UK.,National Institute for Health Research (NIHR) Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| |
Collapse
|
21
|
|
22
|
Wojnowski W, Dymerski T, Gębicki J, Namieśnik J. Electronic Noses in Medical Diagnostics. Curr Med Chem 2019; 26:197-215. [PMID: 28982314 DOI: 10.2174/0929867324666171004164636] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2016] [Revised: 05/24/2016] [Accepted: 09/05/2016] [Indexed: 01/13/2023]
Abstract
BACKGROUND Electronic nose technology is being developed in order to analyse complex mixtures of volatiles in a way parallel to biologic olfaction. When applied in the field of medicine, the use of such devices should enable the identification and discrimination between different diseases. In this review, a comprehensive summary of research in medical diagnostics using electronic noses is presented. A special attention has been paid to the application of these devices and sensor technologies, in response to current trends in medicine. METHODS Peer-reviewed research literature pertaining to the subject matter was identified based on a search of bibliographic databases. The quality and relevance of retrieved papers was assessed using standard tools. Their content was critically reviewed and certain information contained therein was compiled in tabularized form. RESULTS The majority of reviewed studies show promising results, often surpassing the accuracy and sensitivity of established diagnostic methods. However, only a relatively small number of devices have been field tested. The methods used for sample collection and data processing in various studies were listed in a table, together with electronic nose models used in these investigations. CONCLUSION Despite the fact that devices equipped with arrays of chemical sensors are not routinely used in everyday medical practice, their prospective use would solve some established issues in medical diagnostics, as well as lead to developments in prophylactics by facilitating a widespread use of non-invasive screening tests.
Collapse
Affiliation(s)
- Wojciech Wojnowski
- Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology, Gdansk, Poland
| | - Tomasz Dymerski
- Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology, Gdansk, Poland
| | - Jacek Gębicki
- Department of Chemical and Process Engineering, Chemical Faculty, Gdansk University of Technology, Gdansk, Poland
| | - Jacek Namieśnik
- Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology, Gdansk, Poland
| |
Collapse
|
23
|
Davis MD, Fowler SJ, Montpetit AJ. Exhaled breath testing - A tool for the clinician and researcher. Paediatr Respir Rev 2019; 29:37-41. [PMID: 29921519 DOI: 10.1016/j.prrv.2018.05.002] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 05/09/2018] [Indexed: 02/06/2023]
Abstract
Exhaled breath is a robust matrix of biomarkers divided between three fractions - gaseous breath, volatile breath, and breath condensate. Breath is collected non-invasively through bags (for gaseous breath), cold condensation chambers (breath condensate), and adsorbent traps (volatile breath). Due to the incredibly dilute nature of breath matrices, breath biomarker analysis requires precise analytical techniques, highly sensitive technology and often challenges the limit of detection of even the most advanced assays. Interest and advances in breath collection, analysis, and use have increased in recent years largely due to advances in analytical technology. Approved and validated breath tests are available as tools for researchers and clinicians. Novel development is ongoing. This article reviews the current applications for exhaled breath biomarkers.
Collapse
Affiliation(s)
- Michael D Davis
- Division of Pulmonary Medicine, Children's Hospital of Richmond at VCU, Hermes A. Kontos Medical Sciences Building - Room 215, 1217 E. Marshall Street, Richmond, VA 23298, USA.
| | - Stephen J Fowler
- Division of Infection, Immunity and Respiratory Medicine, School of Biological Sciences, The University of Manchester and Manchester University NHS Foundation Trust, Manchester, UK.
| | - Alison J Montpetit
- VCU Health, Department of Emergency Medicine, Adult Emergency Department, Richmond, VA, USA.
| |
Collapse
|
24
|
Sample preparation and recent trends in volatolomics for diagnosing gastrointestinal diseases. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.08.020] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
25
|
Chappuis TH, Pham Ho BA, Ceillier M, Ricoul F, Alessio M, Beche JF, Corne C, Besson G, Vial J, Thiébaut D, Bourlon B. Miniaturization of breath sampling with silicon chip: application to volatile tobacco markers tracking. J Breath Res 2018; 12:046011. [PMID: 30008462 DOI: 10.1088/1752-7163/aad384] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This work presents the performances of silicon micro-preconcentrators chips for breath sampling. The silicon chips were coupled to a handheld battery powered system for breath sampling and direct injection in a laboratory gas chromatography mass spectrometry system through thermal desorption (TD). Performances of micro-preconcentrators were first compared to commercial TD for benzene trapping. Similar chromatographic peaks after gas chromatographic separation were observed while the volume of sample needed was reduced by a factor of 5. Repeatability and day to day variability of the micro-preconcentrators were then studied for a 500 ppb synthetic model mixture injected three times a day four days in a row: 8% and 12% were measured respectively. Micro-preconcentrator to micro-preconcentrator variability was not significant compared to day to day variability. In addition, micro-preconcentrators were tested for breath samples collected in Tedlar® bags. Three analyses of the same breath sample displayed relative standard deviations values below 16% for eight of the ten most intense peaks. Finally, the performances of micro-preconcentrators for breath sampling on a single expiration were illustrated with the example of volatile tobacco markers tracking. The signals of three smoking markers in breath, benzene, 2,5-dimethylfuran, and toluene were studied. Concentrations of benzene and toluene were found to be 10 to 100 higher in the breath of smokers. 2,5-dimethylfuran was only found in the breath of smokers. The elimination kinetics of the markers were followed as well during 4 h: a fast decrease of the signal of the three markers in breath was observed 20 min after smoking in good agreement with what is described in the literature. Those results demonstrate the efficiency of silicon chips for breath sampling, compared to the state of the art techniques. Thanks to miniaturization and lower sample volumes needed, micro-preconcentrators could be in the future a key technology towards portable breath sampling and analysis.
Collapse
Affiliation(s)
- Thomas Hector Chappuis
- Univ. Grenoble Alpes, CEA, LETI, MINATEC Campus, F-38000 Grenoble, France. UMR 8231 CBI, LSABM, ESPCI Paris-CNRS, PSL Institute, Paris, France
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Jalal AH, Alam F, Roychoudhury S, Umasankar Y, Pala N, Bhansali S. Prospects and Challenges of Volatile Organic Compound Sensors in Human Healthcare. ACS Sens 2018; 3:1246-1263. [PMID: 29879839 DOI: 10.1021/acssensors.8b00400] [Citation(s) in RCA: 91] [Impact Index Per Article: 15.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The chemical signatures of volatile organic compounds (VOCs) in humans can be utilized for point-of-care (POC) diagnosis. Apart from toxic exposure studies, VOCs generated in humans can provide insights into one's healthy and diseased metabolic states, acting as a biomarker for identifying numerous diseases noninvasively. VOC sensors and the technology of e-nose have received significant attention for continuous and selective monitoring of various physiological and pathophysiological conditions of an individual. Noninvasive detection of VOCs is achieved from biomatrices of breath, sweat and saliva. Among these, detection from sweat and saliva can be continuous in real-time. The sensing approaches include optical, chemiresistive and electrochemical techniques. This article provides an overview of such techniques. These, however, have limitations of reliability, precision, selectivity, and stability in continuous monitoring. Such limitations are due to lack of sensor stability and complexity of samples in a multivariate environment, which can lead to false readings. To overcome selectivity barriers, sensor arrays enabling multimodal sensing, have been used with pattern recognition techniques. Stability and precision issues have been addressed through advancements in nanotechnology. The use of various forms of nanomaterial not only enhance sensing performance, but also plays a major role in detection on a miniaturized scale. The rapid growth in medical Internet of Things (IoT) and artificial intelligence paves a pathway for improvements in human theranostics.
Collapse
Affiliation(s)
- Ahmed H. Jalal
- Department of Electrical and Computer Engineering, Florida International University, Miami, Florida 33174, United States
| | - Fahmida Alam
- Department of Electrical and Computer Engineering, Florida International University, Miami, Florida 33174, United States
| | - Sohini Roychoudhury
- Department of Electrical and Computer Engineering, Florida International University, Miami, Florida 33174, United States
| | - Yogeswaran Umasankar
- Biomolecular Sciences Institute, Florida International University, Miami, Florida 33199, United States
| | - Nezih Pala
- Department of Electrical and Computer Engineering, Florida International University, Miami, Florida 33174, United States
| | - Shekhar Bhansali
- Department of Electrical and Computer Engineering, Florida International University, Miami, Florida 33174, United States
| |
Collapse
|
27
|
Natural menstrual rhythm and oral contraception diversely affect exhaled breath compositions. Sci Rep 2018; 8:10838. [PMID: 30022081 PMCID: PMC6052073 DOI: 10.1038/s41598-018-29221-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Accepted: 07/09/2018] [Indexed: 12/17/2022] Open
Abstract
Natural menstrual cycle and/or oral contraception diversely affect women metabolites. Longitudinal metabolic profiling under constant experimental conditions is thereby realistic to understand such effects. Thus, we investigated volatile organic compounds (VOCs) exhalation throughout menstrual cycles in 24 young and healthy women with- and without oral contraception. Exhaled VOCs were identified and quantified in trace concentrations via high-resolution real-time mass-spectrometry, starting from a menstruation and then repeated follow-up with six intervals including the next bleeding. Repeated measurements within biologically comparable groups were employed under optimized measurement setup. We observed pronounced and substance specific changes in exhaled VOC concentrations throughout all cycles with low intra-individual variations. Certain blood-borne volatiles changed significantly during follicular and luteal phases. Most prominent changes in endogenous VOCs were observed at the ovulation phase with respect to initial menstruation. Here, the absolute median abundances of alveolar ammonia, acetone, isoprene and dimethyl sulphide changed significantly (P-value ≤ 0.005) by 18.22↓, 13.41↓, 18.02↑ and 9.40↓%, respectively. These VOCs behaved in contrast under the presence of combined oral contraception; e.g. isoprene decreased significantly by 30.25↓%. All changes returned to initial range once the second bleeding phase was repeated. Changes in exogenous benzene, isopropanol, limonene etc. and smoking related furan, acetonitrile and orally originated hydrogen sulphide were rather nonspecific and mainly exposure dependent. Our observations could apprehend a number of known/pre-investigated metabolic effects induced by monthly endocrine regulations. Potential in vivo origins (e.g. metabolic processes) of VOCs are crucial to realize such effects. Despite ubiquitous confounders, we demonstrated the true strength of volatolomics for metabolic monitoring of menstrual cycle and contraceptives. These outcomes may warrant further studies in this direction to enhance our fundamental and clinical understanding on menstrual metabolomics and endocrinology. Counter-effects of contraception can be deployed for future noninvasive assessment of birth control pills. Our findings could be translated toward metabolomics of pregnancy, menopause and post-menopausal complications via breath analysis.
Collapse
|
28
|
Rydosz A. Sensors for Enhanced Detection of Acetone as a Potential Tool for Noninvasive Diabetes Monitoring. SENSORS 2018; 18:s18072298. [PMID: 30012960 PMCID: PMC6068483 DOI: 10.3390/s18072298] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2018] [Revised: 07/03/2018] [Accepted: 07/16/2018] [Indexed: 01/17/2023]
Abstract
Measurement of blood-borne volatile organic compounds (VOCs) occurring in human exhaled breath as a result of metabolic changes or pathological disorders is a promising tool for noninvasive medical diagnosis, such as exhaled acetone measurements in terms of diabetes monitoring. The conventional methods for exhaled breath analysis are based on spectrometry techniques, however, the development of gas sensors has made them more and more attractive from a medical point of view. This review focuses on the latest achievements in gas sensors for exhaled acetone detection. Several different methods and techniques are presented and discussed as well.
Collapse
Affiliation(s)
- Artur Rydosz
- Department of Electronics, AGH University of Science and Technology, 30-059 Krakow, Poland.
| |
Collapse
|
29
|
Doping-assisted low-pressure photoionization mass spectrometry for the real-time detection of lung cancer-related volatile organic compounds. Talanta 2016; 165:98-106. [PMID: 28153325 DOI: 10.1016/j.talanta.2016.12.039] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2016] [Revised: 12/16/2016] [Accepted: 12/18/2016] [Indexed: 01/15/2023]
Abstract
Real-time detection of lung cancer-related volatile organic compounds (VOCs) is a promising, non-intrusive technique for lung cancer (LC) prescreening. In this study, a novel method was designed to enhance the detection selectivity and sensitivity of LC-related polar VOCs by dichloromethane (CH2Cl2) doping-assisted low-pressure photoionization mass spectrometry (LPPI-MS). Compared with conventional LPPI-MS, CH2Cl2 doping-assisted LPPI-MS boosted the peak intensities of n-propanol, n-pentanal, acetone, and butyl acetate in nitrogen specifically by 53, 18, 16, and 43 times, respectively. The signal intensities of their daughter ions were inhibited or reduced. At relative humidity (RH) of 20%, the sensitivities of n-propanol, n-pentanal, acetone, and butyl acetate detection ranged from 116 to 452 counts/ppbv with a detection time of 10s and R2 >0.99 for the linear calibration curves. The method was also applicable under higher RH levels of 50% and 90%. Breath samples obtained from 10 volunteers and spiked samples were investigated. Eight-fold enhancements in the signal intensities of polar VOCs were observed in the normal and spiked samples. These preliminary results demonstrate the efficacy of the dichloromethane doping-assisted LPPI technique for the detection of LC-related polar VOCs. Further studies are indispensible to illustrating the detailed mechanism and applying the technique to breath diagnosis.
Collapse
|
30
|
Schallschmidt K, Becker R, Jung C, Bremser W, Walles T, Neudecker J, Leschber G, Frese S, Nehls I. Comparison of volatile organic compounds from lung cancer patients and healthy controls-challenges and limitations of an observational study. J Breath Res 2016; 10:046007. [PMID: 27732569 DOI: 10.1088/1752-7155/10/4/046007] [Citation(s) in RCA: 69] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
This paper outlines the design and performance of an observational study on the profiles of volatile organic compounds (VOCs) in the breath of 37 lung cancer patients and 23 healthy controls of similar age. The need to quantify each VOC considered as a potential disease marker on the basis of individual calibration is elaborated, and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using solid phase microextraction-gas chromatography-mass spectrometry over a study period of 14 months are described. Twenty-four VOCs were quantified on the basis of their previously suggested potential as cancer markers. The concentration of aromatic compounds in the breath was increased, as expected, in smokers, while lung cancer patients displayed significantly increased levels of oxygenated VOCs such as aldehydes, 2-butanone and 1-butanol. Although sets of selected oxygenated VOCs displayed sensitivities and specificities between 80% and 90% using linear discriminant analysis (LDA) with leave-one-out cross validation, the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results are discussed against the background of the literature on volatile cancer marker investigations and the prospects of linking increased VOC levels in patients' breath with approaches that employ sniffer dogs. Experience from this study and the literature suggests that the currently available methodology is not able to use breath VOCs to reliably discriminate between cancer patients and healthy controls. Observational studies often tend to note significant differences in levels of certain oxygenated VOCs, but without the resolution required for practical application. Any step towards the exploitation of differences in VOC profiles for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect unstable marker candidates.
Collapse
|
31
|
Boots AW, Bos LD, van der Schee MP, van Schooten FJ, Sterk PJ. Exhaled Molecular Fingerprinting in Diagnosis and Monitoring: Validating Volatile Promises. Trends Mol Med 2016; 21:633-644. [PMID: 26432020 DOI: 10.1016/j.molmed.2015.08.001] [Citation(s) in RCA: 104] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2015] [Revised: 07/23/2015] [Accepted: 08/04/2015] [Indexed: 12/19/2022]
Abstract
Medical diagnosis and phenotyping increasingly incorporate information from complex biological samples. This has promoted the development and clinical application of non-invasive metabolomics in exhaled air (breathomics). In respiratory medicine, expired volatile organic compounds (VOCs) are associated with inflammatory, oxidative, microbial, and neoplastic processes. After recent proof of concept studies demonstrating moderate to good diagnostic accuracies, the latest efforts in breathomics are focused on optimization of sensor technologies and analytical algorithms, as well as on independent validation of clinical classification and prediction. Current research strategies are revealing the underlying pathophysiological pathways as well as clinically-acceptable levels of diagnostic accuracy. Implementing recent guidelines on validating molecular signatures in medicine will enhance the clinical potential of breathomics and the development of point-of-care technologies.
Collapse
Affiliation(s)
- Agnes W Boots
- Department of Toxicology, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands.
| | - Lieuwe D Bos
- Department of Respiratory Medicine, Academic Medical Centre, University of Medical Centre Amsterdam, The Netherlands
| | - Marc P van der Schee
- Department of Respiratory Medicine, Academic Medical Centre, University of Medical Centre Amsterdam, The Netherlands; Department of Pediatric Pulmonology, Emma's Children's Hospital, Academic Medical Centre Amsterdam, The Netherlands
| | - Frederik-Jan van Schooten
- Department of Toxicology, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands
| | - Peter J Sterk
- Department of Respiratory Medicine, Academic Medical Centre, University of Medical Centre Amsterdam, The Netherlands
| |
Collapse
|
32
|
Gruber B, Keller S, Groeger T, Matuschek G, Szymczak W, Zimmermann R. Breath gas monitoring during a glucose challenge by a combined PTR-QMS/GC×GC-TOFMS approach for the verification of potential volatile biomarkers. J Breath Res 2016; 10:036003. [DOI: 10.1088/1752-7155/10/3/036003] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
33
|
FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests. Sci Rep 2016; 6:28029. [PMID: 27311826 PMCID: PMC4911606 DOI: 10.1038/srep28029] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Accepted: 05/27/2016] [Indexed: 12/23/2022] Open
Abstract
Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange.
Collapse
|
34
|
Abstract
Breath volatile organic compound analysis may open a non-invasive window onto (patho)physiological and metabolic processes in the body. Breath tests require controlled sampling with respect to different breath phases and on-site and point-of-care applicability. Microextraction techniques such as solid phase microextraction (SPME) or needle-trap microextraction (NTME) meet these requirements. Small sample volumes and fast and controlled sample preparation combine on-site sampling and pre-concentration in one step. Detection limits in the low ppbV range and fast and simple processing facilitate the application of distribution-based SPME for screening and targeted analysis. Exhaustive NTME has shown further advantages such as fast and automated sampling, improved stability and reproducibility with improved detection limits. Combinations of different sorbents and thermal expansion desorption have shown most promising properties when applied to water saturated breath samples. This article addresses major challenges and advantages of microextraction techniques in breath analysis. Important progress, current applications and future trends are discussed.
Collapse
|
35
|
Szabó A, Ruzsanyi V, Unterkofler K, Mohácsi Á, Tuboly E, Boros M, Szabó G, Hinterhuber H, Amann A. Exhaled methane concentration profiles during exercise on an ergometer. J Breath Res 2015; 9:016009. [PMID: 25749807 DOI: 10.1088/1752-7155/9/1/016009] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Exhaled methane concentration measurements are extensively used in medical investigation of certain gastrointestinal conditions. However, the dynamics of endogenous methane release is largely unknown. Breath methane profiles during ergometer tests were measured by means of a photoacoustic spectroscopy based sensor. Five methane-producing volunteers (with exhaled methane level being at least 1 ppm higher than room air) were measured. The experimental protocol consisted of 5 min rest--15 min pedalling (at a workload of 75 W)--5 min rest. In addition, hemodynamic and respiratory parameters were determined and compared to the estimated alveolar methane concentration. The alveolar breath methane level decreased considerably, by a factor of 3-4 within 1.5 min, while the estimated ventilation-perfusion ratio increased by a factor of 2-3. Mean pre-exercise and exercise methane concentrations were 11.4 ppm (SD:7.3) and 2.8 ppm (SD:1.9), respectively. The changes can be described by the high sensitivity of exhaled methane to ventilation-perfusion ratio and are in line with the Farhi equation.
Collapse
Affiliation(s)
- A Szabó
- MTA-SZTE Research Group on Photoacoustic Spectroscopy, Dóm tér 9, 6720 Szeged, Hungary. Department of Optics and Quantum Electronics, Faculty of Science and Informatics, University of Szeged, Dóm tér 9, 6720 Szeged, Hungary
| | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Real-time analysis of organic compounds in ship engine aerosol emissions using resonance-enhanced multiphoton ionisation and proton transfer mass spectrometry. Anal Bioanal Chem 2015; 407:5939-51. [DOI: 10.1007/s00216-015-8465-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2014] [Revised: 12/28/2014] [Accepted: 01/05/2015] [Indexed: 10/24/2022]
|
37
|
Kleeblatt J, Schubert JK, Zimmermann R. Detection of Gaseous Compounds by Needle Trap Sampling and Direct Thermal-Desorption Photoionization Mass Spectrometry: Concept and Demonstrative Application to Breath Gas Analysis. Anal Chem 2015; 87:1773-81. [DOI: 10.1021/ac5039829] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Juliane Kleeblatt
- Joint
Mass Spectrometry Center, Chair of Analytical Chemistry, Institute
of Chemistry, University of Rostock, Dr.-Lorenz-Weg 1, 18059 Rostock, Germany
- Joint
Mass Spectrometry Center, Comprehensive Molecular Analytics, Helmholtz Zentrum München, Ingolstädter Landstraße 1, 85764 Neuherberg, Germany
| | - Jochen K. Schubert
- Department
of Anesthesia and Intensive Care, University of Rostock, Schillingallee
35, 18057 Rostock, Germany
| | - Ralf Zimmermann
- Joint
Mass Spectrometry Center, Chair of Analytical Chemistry, Institute
of Chemistry, University of Rostock, Dr.-Lorenz-Weg 1, 18059 Rostock, Germany
- Joint
Mass Spectrometry Center, Comprehensive Molecular Analytics, Helmholtz Zentrum München, Ingolstädter Landstraße 1, 85764 Neuherberg, Germany
| |
Collapse
|
38
|
Sun M, Chen Z, Gong Z, Zhao X, Jiang C, Yuan Y, Wang Z, Li Y, Wang C. Determination of breath acetone in 149 Type 2 diabetic patients using a ringdown breath-acetone analyzer. Anal Bioanal Chem 2015; 407:1641-50. [DOI: 10.1007/s00216-014-8401-8] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Revised: 12/03/2014] [Accepted: 12/09/2014] [Indexed: 12/28/2022]
|
39
|
Herbig J, Beauchamp J. Towards standardization in the analysis of breath gas volatiles. J Breath Res 2014; 8:037101. [DOI: 10.1088/1752-7155/8/3/037101] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
40
|
Sukul P, Trefz P, Schubert JK, Miekisch W. Immediate effects of breath holding maneuvers onto composition of exhaled breath. J Breath Res 2014; 8:037102. [DOI: 10.1088/1752-7155/8/3/037102] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
41
|
Berchtold C, Bosilkovska M, Daali Y, Walder B, Zenobi R. Real-time monitoring of exhaled drugs by mass spectrometry. MASS SPECTROMETRY REVIEWS 2014; 33:394-413. [PMID: 24272872 DOI: 10.1002/mas.21393] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Revised: 06/12/2013] [Accepted: 06/13/2013] [Indexed: 06/02/2023]
Abstract
Future individualized patient treatment will need tools to monitor the dose and effects of administrated drugs. Mass spectrometry may become the method of choice to monitor drugs in real time by analyzing exhaled breath. This review describes the monitoring of exhaled drugs in real time by mass spectrometry. The biological background as well as the relevant physical properties of exhaled drugs are delineated. The feasibility of detecting and monitoring exhaled drugs is discussed in several examples. The mass spectrometric tools that are currently available to analyze breath in real time are reviewed. The technical needs and state of the art for on-site measurements by mass spectrometry are also discussed in detail. Off-line methods, which give support and are an important source of information for real-time measurements, are also discussed. Finally, some examples of drugs that have already been successfully detected in exhaled breath, including propofol, fentanyl, methadone, nicotine, and valproic acid are presented. Real-time monitoring of exhaled drugs by mass spectrometry is a relatively new field, which is still in the early stages of development. New technologies promise substantial benefit for future patient monitoring and treatment.
Collapse
Affiliation(s)
- Christian Berchtold
- Department of Chemistry and Applied Biosciences, ETH Zürich, CH-8093, Zürich, Switzerland
| | | | | | | | | |
Collapse
|
42
|
Amann A, Costello BDL, Miekisch W, Schubert J, Buszewski B, Pleil J, Ratcliffe N, Risby T. The human volatilome: volatile organic compounds (VOCs) in exhaled breath, skin emanations, urine, feces and saliva. J Breath Res 2014; 8:034001. [PMID: 24946087 DOI: 10.1088/1752-7155/8/3/034001] [Citation(s) in RCA: 361] [Impact Index Per Article: 36.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Breath analysis is a young field of research with its roots in antiquity. Antoine Lavoisier discovered carbon dioxide in exhaled breath during the period 1777-1783, Wilhelm (Vilém) Petters discovered acetone in breath in 1857 and Johannes Müller reported the first quantitative measurements of acetone in 1898. A recent review reported 1765 volatile compounds appearing in exhaled breath, skin emanations, urine, saliva, human breast milk, blood and feces. For a large number of compounds, real-time analysis of exhaled breath or skin emanations has been performed, e.g., during exertion of effort on a stationary bicycle or during sleep. Volatile compounds in exhaled breath, which record historical exposure, are called the 'exposome'. Changes in biogenic volatile organic compound concentrations can be used to mirror metabolic or (patho)physiological processes in the whole body or blood concentrations of drugs (e.g. propofol) in clinical settings-even during artificial ventilation or during surgery. Also compounds released by bacterial strains like Pseudomonas aeruginosa or Streptococcus pneumonia could be very interesting. Methyl methacrylate (CAS 80-62-6), for example, was observed in the headspace of Streptococcus pneumonia in concentrations up to 1420 ppb. Fecal volatiles have been implicated in differentiating certain infectious bowel diseases such as Clostridium difficile, Campylobacter, Salmonella and Cholera. They have also been used to differentiate other non-infectious conditions such as irritable bowel syndrome and inflammatory bowel disease. In addition, alterations in urine volatiles have been used to detect urinary tract infections, bladder, prostate and other cancers. Peroxidation of lipids and other biomolecules by reactive oxygen species produce volatile compounds like ethane and 1-pentane. Noninvasive detection and therapeutic monitoring of oxidative stress would be highly desirable in autoimmunological, neurological, inflammatory diseases and cancer, but also during surgery and in intensive care units. The investigation of cell cultures opens up new possibilities for elucidation of the biochemical background of volatile compounds. In future studies, combined investigations of a particular compound with regard to human matrices such as breath, urine, saliva and cell culture investigations will lead to novel scientific progress in the field.
Collapse
Affiliation(s)
- Anton Amann
- Univ-Clinic for Anesthesia and Intensive Care, Innsbruck Medical University, Anichstr, 35, A-6020 Innsbruck, Austria. Breath Research Institute of the University of Innsbruck, Rathausplatz 4, A-6850 Dornbirn, Austria
| | | | | | | | | | | | | | | |
Collapse
|
43
|
Perez-Guaita D, Kokoric V, Wilk A, Garrigues S, Mizaikoff B. Towards the determination of isoprene in human breath using substrate-integrated hollow waveguide mid-infrared sensors. J Breath Res 2014; 8:026003. [PMID: 24848160 DOI: 10.1088/1752-7155/8/2/026003] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Selected volatile organic compounds (VOCs) in breath may be considered biomarkers if they are indicative of distinct diseases or disease states. Given the inherent molecular selectivity of vibrational spectroscopy, infrared sensing technologies appear ideally suitable for the determination of endogenous VOCs in breath. The aim of this study was to determine that mid-infrared (MIR; 3-20 µm) gas phase sensing is capable of determining isoprene in exhaled breath as an exemplary medically relevant VOC by hyphenating novel substrate-integrated hollow waveguides (iHWG) with a likewise miniaturized preconcentration system. A compact preconcentrator column for sampling isoprene from exhaled breath was coupled to an iHWG serving simultaneously as highly miniaturized gas cell and light conduit in combination with a compact Fourier transform infrared spectrometer. A gas mixing system enabled extensive system calibration using isoprene standards. After system optimization, a calibration function obtaining a limit of quantification of 106 ppb was achieved. According to the literature, the obtained sensitivity is sufficient for quantifying middle to high isoprene concentrations occurring in exhaled breath. Finally, a volunteer breath sample was analysed proving comparable values of isoprene in a real-world scenario. Despite its fundamental utility, the proposed methodology contains some limitations in terms of sensitivity and temporal resolution in comparison with the readily available measurement techniques that should be addressed during future optimization of the system. Nonetheless, this study presents the first determination of endogenous VOCs in breath via advanced hollow waveguide MIR sensor technology, clearly demonstrating its potential for the analysis of volatile biomarkers in exhaled breath.
Collapse
Affiliation(s)
- David Perez-Guaita
- Analytical Chemistry Department, University of Valencia, EdificiJeroni Muñoz, Burjassot, Spain
| | | | | | | | | |
Collapse
|
44
|
Smith D, Španěl P, Herbig J, Beauchamp J. Mass spectrometry for real-time quantitative breath analysis. J Breath Res 2014; 8:027101. [PMID: 24682047 DOI: 10.1088/1752-7155/8/2/027101] [Citation(s) in RCA: 117] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
45
|
Amann A, Miekisch W, Schubert J, Buszewski B, Ligor T, Jezierski T, Pleil J, Risby T. Analysis of exhaled breath for disease detection. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2014; 7:455-482. [PMID: 25014347 DOI: 10.1146/annurev-anchem-071213-020043] [Citation(s) in RCA: 107] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Breath analysis is a young field of research with great clinical potential. As a result of this interest, researchers have developed new analytical techniques that permit real-time analysis of exhaled breath with breath-to-breath resolution in addition to the conventional central laboratory methods using gas chromatography-mass spectrometry. Breath tests are based on endogenously produced volatiles, metabolites of ingested precursors, metabolites produced by bacteria in the gut or the airways, or volatiles appearing after environmental exposure. The composition of exhaled breath may contain valuable information for patients presenting with asthma, renal and liver diseases, lung cancer, chronic obstructive pulmonary disease, inflammatory lung disease, or metabolic disorders. In addition, oxidative stress status may be monitored via volatile products of lipid peroxidation. Measurement of enzyme activity provides phenotypic information important in personalized medicine, whereas breath measurements provide insight into perturbations of the human exposome and can be interpreted as preclinical signals of adverse outcome pathways.
Collapse
Affiliation(s)
- Anton Amann
- Breath Research Institute of the University of Innsbruck, A-6850 Dornbirn, Austria;
| | | | | | | | | | | | | | | |
Collapse
|
46
|
Trefz P, Schmidt M, Oertel P, Obermeier J, Brock B, Kamysek S, Dunkl J, Zimmermann R, Schubert JK, Miekisch W. Continuous Real Time Breath Gas Monitoring in the Clinical Environment by Proton-Transfer-Reaction-Time-of-Flight-Mass Spectrometry. Anal Chem 2013; 85:10321-9. [DOI: 10.1021/ac402298v] [Citation(s) in RCA: 100] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Affiliation(s)
- Phillip Trefz
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Markus Schmidt
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Peter Oertel
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Juliane Obermeier
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Beate Brock
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Svend Kamysek
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Jürgen Dunkl
- Ionicon Analytik GmbH, Eduard-Bodem-Gasse 3, A-6020 Innsbruck, Austria
| | - Ralf Zimmermann
- Joint Mass Spectrometry
Centre, Chair of Analytical Chemistry, University of Rostock, Dr. Lorenz Weg
1, 18059 Rostock, Germany and Joint Mass Spectrometry Centre, Cooperation Group “Comprehensive
Molecular Analytics”, Helmholtz Zentrum München, D-85764 Neuherberg, Germany
| | - Jochen K. Schubert
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Wolfram Miekisch
- Department of Anaesthesia
and Intensive Care, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| |
Collapse
|
47
|
Wang Z, Wang C. Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements. J Breath Res 2013; 7:037109. [DOI: 10.1088/1752-7155/7/3/037109] [Citation(s) in RCA: 164] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
48
|
Déléris I, Saint-Eve A, Sémon E, Guillemin H, Guichard E, Souchon I, Le Quéré JL. Comparison of direct mass spectrometry methods for the on-line analysis of volatile compounds in foods. JOURNAL OF MASS SPECTROMETRY : JMS 2013; 48:594-607. [PMID: 23674284 DOI: 10.1002/jms.3199] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2012] [Revised: 01/24/2013] [Accepted: 02/22/2013] [Indexed: 06/02/2023]
Abstract
For the on-line monitoring of flavour compound release, atmospheric pressure chemical ionization (APCI) and proton transfer reaction (PTR) combined to mass spectrometry (MS) are the most often used ionization technologies. APCI-MS was questioned for the quantification of volatiles in complex mixtures, but direct comparisons of APCI and PTR techniques applied on the same samples remain scarce. The aim of this work was to compare the potentialities of both techniques for the study of in vitro and in vivo flavour release. Aroma release from flavoured aqueous solutions (in vitro measurements in Teflon bags and glass vials) or flavoured candies (in vivo measurements on six panellists) was studied using APCI- and PTR-MS. Very similar results were obtained with both techniques. Their sensitivities, expressed as limit of detection of 2,5-dimethylpyrazine, were found equivalent at 12 ng/l air. Analyses of Teflon bag headspace revealed a poor repeatability and important ionization competitions with both APCI- and PTR-MS, particularly between an ester and a secondary alcohol. These phenomena were attributed to dependency on moisture content, gas/liquid volume ratio, proton affinities and product ion distribution, together with inherent drawbacks of Teflon bags (adsorption, condensation of water and polar molecules). Concerning the analyses of vial headspace and in vivo analyses, similar results were obtained with both techniques, revealing no competition phenomena. This study highlighted the equivalent performances of APCI-MS and PTR-MS for in vitro and in vivo flavour release investigations and provided useful data on the problematic use of sample bags for headspace analyses.
Collapse
Affiliation(s)
- Isabelle Déléris
- INRA, UMR 782, Laboratoire de Génie et Microbiologie des Procédés Alimentaires (GMPA), F-78850, Thiverval-Grignon, France.
| | | | | | | | | | | | | |
Collapse
|
49
|
Hornuss C, Dolch ME, Janitza S, Souza K, Praun S, Apfel CC, Schelling G. Determination of breath isoprene allows the identification of the expiratory fraction of the propofol breath signal during real-time propofol breath monitoring. J Clin Monit Comput 2013; 27:509-16. [PMID: 23525901 DOI: 10.1007/s10877-013-9452-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2012] [Accepted: 03/08/2013] [Indexed: 12/18/2022]
Abstract
Real-time measurement of propofol in the breath may be used for routine clinical monitoring. However, this requires unequivocal identification of the expiratory phase of the respiratory propofol signal as only expiratory propofol reflects propofol blood concentrations. Determination of CO2 breath concentrations is the current gold standard for the identification of expiratory gas but usually requires additional equipment. Human breath also contains isoprene, a volatile organic compound with low inspiratory breath concentration and an expiratory concentration plateau. We investigated whether breath isoprene could be used similarly to CO2 to identify the expiratory fraction of the propofol breath signal. We investigated real-time breath data obtained from 40 study subjects during routine anesthesia. Propofol, isoprene, and CO2 breath concentrations were determined by a combined ion molecule reaction/electron impact mass spectrometry system. The expiratory propofol signal was identified according to breath CO2 and isoprene concentrations and presented as median of intervals of 30 s duration. Bland-Altman analysis was applied to detect differences (bias) in the expiratory propofol signal extracted by the two identification methods. We investigated propofol signals in a total of 3,590 observation intervals of 30 s duration in the 40 study subjects. In 51.4 % of the intervals (1,844/3,590) both methods extracted the same results for expiratory propofol signal. Overall bias between the two data extraction methods was -0.12 ppb. The lower and the upper limits of the 95 % CI were -0.69 and 0.45 ppb. Determination of isoprene breath concentrations allows the identification of the expiratory propofol signal during real-time breath monitoring.
Collapse
Affiliation(s)
- Cyrill Hornuss
- Department of Anaesthesiology, Klinikum der Universität München, Marchioninistr. 15, 81377, Munich, Germany,
| | | | | | | | | | | | | |
Collapse
|
50
|
Evaluation of needle trap micro-extraction and automatic alveolar sampling for point-of-care breath analysis. Anal Bioanal Chem 2013; 405:3105-15. [DOI: 10.1007/s00216-013-6781-9] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2012] [Revised: 01/23/2013] [Accepted: 01/23/2013] [Indexed: 10/27/2022]
|