1
|
Bulut E, Johansen PM, Elbualy A, Kalman C, Mayer R, Kato N, Salmeron de Toledo Aguiar R, Pilitsis JG. How Long Does Deep Brain Stimulation Give Patients Benefit? Neuromodulation 2025; 28:472-483. [PMID: 39001725 DOI: 10.1016/j.neurom.2024.05.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 05/01/2024] [Accepted: 05/22/2024] [Indexed: 07/15/2024]
Abstract
INTRODUCTION One of the most common questions patients ask when they are contemplating deep brain stimulation (DBS) is how long it will last. To guide physicians in answering this query, we performed a scoping review to assess the current state of the literature and to identify the gaps that need to be addressed. MATERIALS AND METHODS The authors performed a MEDLINE search inclusive of articles from January 1987 (advent of DBS literature) to June 2023 including human and modeling studies written in English. For longevity of therapy data, only studies with a mean follow-up of ≥three years were included. Using the Rayyan platform, two reviewers (JP and RM) performed a title screen. Of the 734 articles, 205 were selected by title screen and 109 from abstract review. Ultimately, a total of 122 articles were reviewed. The research questions we explored were 1) how long can the different components of the DBS system maintain functionality? and 2) how long can DBS remain efficacious in treating Parkinson's disease (PD), essential tremor (ET), dystonia, and other disorders? RESULTS We showed that patients with PD, ET, and dystonia maintain a considerable long-term benefit in motor scores seven to ten years after implant, although the percentage improvement decreases over time. Stimulation off scores in PD and ET show worsening, consistent with disease progression. Battery life varies by the disease treated and the programming settings used. There remains a paucity of literature after ten years, and the impact of new device technology has not been classified to date. CONCLUSION We reviewed existing data on DBS longevity. Overall, outcomes data after ten years of therapy are substantially limited in the current literature. We recommend that physicians who have data for patients with DBS exceeding this duration publish their results.
Collapse
Affiliation(s)
- Esin Bulut
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA
| | - P Mitchell Johansen
- Department of Neurosurgery and Brain Repair, University of South Florida, Tampa, FL, USA
| | - Alya Elbualy
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA
| | - Cheyenne Kalman
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA
| | - Ryan Mayer
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA
| | - Nicholas Kato
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA
| | | | - Julie G Pilitsis
- Department of Neurosurgery, University of Arizona, Tucson, AZ, USA.
| |
Collapse
|
2
|
Özgan D, Krieg SM, Jakobs M. Meta-analysis and review of rechargeable implantable pulse generators for spinal cord stimulation and deep brain stimulation. BRAIN & SPINE 2024; 4:104148. [PMID: 39669716 PMCID: PMC11634974 DOI: 10.1016/j.bas.2024.104148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2024] [Revised: 11/22/2024] [Accepted: 11/25/2024] [Indexed: 12/14/2024]
Abstract
Introduction Neuromodulation through deep brain stimulation (DBS) and spinal cord stimulation (SCS) has become a successful therapy for various neurological disorders, such as movement disorders and chronic pain. Implantable pulse generators (IPGs) are pivotal in these therapies, available as either rechargeable (r-IPGs) or non-rechargeable (nr-IPGs). Research question To perform a meta-analysis on r-IPGs. Methods A systematic literature search following PRISMA guidelines was conducted on PubMed, focusing on studies published from January 2005 to August 2023. Included studies comprised clinical trials, randomized controlled trials, and comparative studies involving human subjects. Data extraction focused on patient demographics, stimulation types, battery characteristics, and complications. Descriptive statistics and Pearson correlation analyses were performed using SPSS software. Results Nine studies involving 288 patients with rechargeable IPGs (r-IPGs) for SCS and 257 patients with r-IPGs for DBS met the inclusion criteria. r-IPGs exhibited low rates of surgical revisions and infections, with surgical revision rates of 8.87% for SCS and 5.45% for DBS, and infection rates of 2.6% for SCS and 1.56% for DBS. Charge burden was comparable with 97.34 min and 93.41 min per week for SCS and DBS respectively. Correlation analyses indicated that longer battery recharge times were associated with an increased incidence of complications, including unintentional interruptions and hardware failures. Discussion r-IPGs may offer substantial benefits in reducing re-operation rates and complications associated. Nonetheless, careful management of battery charging is crucial to maximize these benefits. Establishing international guidelines for the use of r-IPGs in specific patient populations and conditions is recommended to standardize and optimize outcomes.
Collapse
Affiliation(s)
- Denizhan Özgan
- Medical School of İstanbul Okan University, İstanbul, Turkiye
| | - Sandro M. Krieg
- Department of Neurosurgery, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg University, Medical Faculty, Heidelberg, Germany
| | - Martin Jakobs
- Department of Neurosurgery, Heidelberg University Hospital, Heidelberg, Germany
- Division of Stereotactic Neurosurgery, Department of Neurosurgery, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg University, Medical Faculty, Heidelberg, Germany
| |
Collapse
|
3
|
Demchenko I, Rampersad S, Datta A, Horn A, Churchill NW, Kennedy SH, Krishnan S, Rueda A, Schweizer TA, Griffiths JD, Boyden ES, Santarnecchi E, Bhat V. Target engagement of the subgenual anterior cingulate cortex with transcranial temporal interference stimulation in major depressive disorder: a protocol for a randomized sham-controlled trial. Front Neurosci 2024; 18:1390250. [PMID: 39268031 PMCID: PMC11390435 DOI: 10.3389/fnins.2024.1390250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 08/06/2024] [Indexed: 09/15/2024] Open
Abstract
Background Transcranial temporal interference stimulation (tTIS) is a new, emerging neurostimulation technology that utilizes two or more electric fields at specific frequencies to modulate the oscillations of neurons at a desired spatial location in the brain. The physics of tTIS offers the advantage of modulating deep brain structures in a non-invasive fashion and with minimal stimulation of the overlying cortex outside of a selected target. As such, tTIS can be effectively employed in the context of therapeutics for the psychiatric disease of disrupted brain connectivity, such as major depressive disorder (MDD). The subgenual anterior cingulate cortex (sgACC), a key brain center that regulates human emotions and influences negative emotional states, is a plausible target for tTIS in MDD based on reports of its successful neuromodulation with invasive deep brain stimulation. Methods This pilot, single-site, double-blind, randomized, sham-controlled interventional clinical trial will be conducted at St. Michael's Hospital - Unity Health Toronto in Toronto, ON, Canada. The primary objective is to demonstrate target engagement of the sgACC with 130 Hz tTIS using resting-state magnetic resonance imaging (MRI) techniques. The secondary objective is to estimate the therapeutic potential of tTIS for MDD by evaluating the change in clinical characteristics of participants and electrophysiological outcomes and providing feasibility and tolerability estimates for a large-scale efficacy trial. Thirty participants (18-65 years) with unipolar, non-psychotic MDD will be recruited and randomized to receive 10 sessions of 130 Hz tTIS or sham stimulation (n = 15 per arm). The trial includes a pre- vs. post-treatment 3T MRI scan of the brain, clinical evaluation, and electroencephalography (EEG) acquisition at rest and during the auditory mismatch negativity (MMN) paradigm. Discussion This study is one of the first-ever clinical trials among patients with psychiatric disorders examining the therapeutic potential of repetitive tTIS and its neurobiological mechanisms. Data obtained from this trial will be used to optimize the tTIS approach and design a large-scale efficacy trial. Research in this area has the potential to provide a novel treatment option for individuals with MDD and circuitry-related disorders and may contribute to the process of obtaining regulatory approval for therapeutic applications of tTIS. Clinical Trial Registration ClinicalTrials.gov, identifier NCT05295888.
Collapse
Affiliation(s)
- Ilya Demchenko
- Interventional Psychiatry Program, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Institute of Medical Science, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), Keenan Research Centre for Biomedical Science, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
| | - Sumientra Rampersad
- Department of Physics, University of Massachusetts Boston, Boston, MA, United States
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, United States
| | - Abhishek Datta
- Research and Development, Soterix Medical, Inc., Woodbridge, NJ, United States
- Department of Biomedical Engineering, City College of New York, New York, NY, United States
| | - Andreas Horn
- Department of Neurology, Center for Brain Circuit Therapeutics, Brigham and Women's Hospital and Harvard Medical School, Boston, MA, United States
- Department of Neurosurgery & Center for NeuroTechnology and NeuroRecovery (CNTR), Department of Neurology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, United States
- Movement Disorder and Neuromodulation Unit, Department of Neurology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt - Universität zu Berlin, Berlin, Germany
| | - Nathan W Churchill
- Keenan Research Centre for Biomedical Science, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Neuroscience Research Program, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
| | - Sidney H Kennedy
- Institute of Medical Science, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Keenan Research Centre for Biomedical Science, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Neuroscience Research Program, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Department of Psychiatry, Temerty Faculty of Medicine, Toronto, ON, Canada
| | - Sridhar Krishnan
- Institute for Biomedical Engineering, Science and Technology (iBEST), Keenan Research Centre for Biomedical Science, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Department of Electrical, Computer, and Biomedical Engineering, Toronto Metropolitan University, Toronto, ON, Canada
| | - Alice Rueda
- Interventional Psychiatry Program, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), Keenan Research Centre for Biomedical Science, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
| | - Tom A Schweizer
- Institute of Medical Science, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), Keenan Research Centre for Biomedical Science, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Keenan Research Centre for Biomedical Science, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Neuroscience Research Program, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Division of Neurosurgery, Department of Surgery, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| | - John D Griffiths
- Institute of Medical Science, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Department of Psychiatry, Temerty Faculty of Medicine, Toronto, ON, Canada
- Krembil Centre for Neuroinformatics, Centre for Addiction and Mental Health (CAMH), Toronto, ON, Canada
| | - Edward S Boyden
- Department of Brain and Cognitive Sciences, Media Arts and Sciences, and Biological Engineering, McGovern Institute for Brain Research and Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, United States
- Howard Hughes Medical Institute, Chevy Chase, MD, United States
| | - Emiliano Santarnecchi
- Precision Neuroscience and Neuromodulation Program, Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, United States
- Department of Neurology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, United States
| | - Venkat Bhat
- Interventional Psychiatry Program, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Institute of Medical Science, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), Keenan Research Centre for Biomedical Science, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Keenan Research Centre for Biomedical Science, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Neuroscience Research Program, St. Michael's Hospital - Unity Health Toronto, Toronto, ON, Canada
- Department of Psychiatry, Temerty Faculty of Medicine, Toronto, ON, Canada
| |
Collapse
|
4
|
Tej Kantu N, Osswald R, Kandel A, Kang J. Resist-as-Needed ADL Training With SPINDLE for Patients With Tremor. IEEE Trans Neural Syst Rehabil Eng 2024; 32:1735-1748. [PMID: 38652620 DOI: 10.1109/tnsre.2024.3392615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
Individuals with neurological disorders often exhibit altered manual dexterity and muscle weakness in their upper limbs. These motor impairments with tremor lead to severe difficulties in performing Activities of Daily Living (ADL). There is a critical need for ADL-focused robotic training that improves individual's strength when engaging with dexterous ADL tasks. This research introduces a new approach to training ADLs by employing a novel robotic rehabilitation system, Spherical Parallel INstrument for Daily Living Emulation (SPINDLE), which incorporates Virtual Reality (VR) to simulate ADL tasks. The study results present the feasibility of training individuals with movements similar to ADLs while interacting with the SPINDLE. A new game-based robotic training paradigm is suggested to perform ADL tasks at various intensity levels of resistance as needed. The proposed system can facilitate the training of various ADLs requiring 3-dimensional rotational movements by providing optimal resistance and visual feedback. We envision this system can be utilized as a table-top home device by restoring the impaired motor function of individuals with tremor and muscle weakness, guiding to improved ADL performance and quality of life.
Collapse
|
5
|
Servello D, Galbiati TF, Iess G, Minafra B, Porta M, Pacchetti C. Complications of deep brain stimulation in Parkinson's disease: a single-center experience of 517 consecutive cases. Acta Neurochir (Wien) 2023; 165:3385-3396. [PMID: 37773459 DOI: 10.1007/s00701-023-05799-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Accepted: 09/03/2023] [Indexed: 10/01/2023]
Abstract
BACKGROUND The number of deep brain stimulation (DBS) procedures is rapidly rising as well as the novel indications. Reporting adverse events related to surgery and to the hardware used is essential to define the risk-to-benefit ratio and develop novel strategies to improve it. OBJECTIVE To analyze DBS complications (both procedure-related and hardware-related) and further assess potential predictive factors. METHODS Five hundred seventeen cases of DBS for Parkinson's disease were performed between 2006 and 2021 in a single center (mean follow-up: 4.68 ± 2.86 years). Spearman's Rho coefficient was calculated to search for a correlation between the occurrence of intracerebral hemorrhage (ICH) and the number of recording tracks. Multiple logistic regression analyzed the probability of developing seizures and ICH given potential risk factors. Kaplan-Meier curves were performed to analyze the cumulative proportions of hardware-related complications. RESULTS Mortality rate was 0.2%, while permanent morbidity 0.6%. 2.5% of cases suffered from ICH which were not influenced by the number of tracks used for recordings. 3.3% reported seizures that were significantly affected by perielectrode brain edema and age. The rate of perielectrode brain edema was significantly higher for Medtronic's leads compared to Boston Scientific's (Χ2(1)= 5.927, P= 0.015). 12.2% of implants reported Hardware-related complications, the most common of which were wound revisions (7.2%). Internal pulse generator models with smaller profiles displayed more favorable hardware-related complication survival curves compared to larger designs (X2(1)= 8.139, P= 0.004). CONCLUSION Overall DBS has to be considered a safe procedure, but future research is needed to decrease the rate of hardware-related complications which may be related to both the surgical technique and to the specific hardware's design. The increased incidence of perielectrode brain edema associated with certain lead models may likewise deserve future investigation.
Collapse
Affiliation(s)
- Domenico Servello
- Neurosurgical Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Lombardia, Italy
| | | | - Guglielmo Iess
- Neurosurgical Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Lombardia, Italy
| | - Brigida Minafra
- Parkinson's Disease and Movement Disorders Unit, IRCCS Mondino Foundation, Pavia, Italy
| | - Mauro Porta
- Neurosurgical Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Lombardia, Italy
| | - Claudio Pacchetti
- Parkinson's Disease and Movement Disorders Unit, IRCCS Mondino Foundation, Pavia, Italy
| |
Collapse
|
6
|
Shlobin NA, Hofmann K, Keating RF, Oluigbo CO. Deep brain stimulation and intrathecal/intraventricular baclofen for glutaric aciduria type 1: A scoping review, individual patient data analysis, and clinical trials review. J Inherit Metab Dis 2023; 46:543-553. [PMID: 37254447 DOI: 10.1002/jimd.12638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 05/24/2023] [Accepted: 05/25/2023] [Indexed: 06/01/2023]
Abstract
Glutaric aciduria type 1 (GA1) is an autosomal recessive disease frequently leading to dystonia. Deep brain stimulation (DBS), intrathecal baclofen (ITB), and intraventricular baclofen (IVB) are the current interventional treatment options for refractory dystonia. We performed a scoping review, individual patient data (IPD) analysis, and clinical trials review to summarize the existing literature on these interventions in this population, characterize outcomes, and suggest directions for future investigation. PubMed, Embase, and Scopus were searched following PRISMA guidelines. IPD were extracted from studies providing IPD for GA1 patients. ClinicalTrials.gov was reviewed. Of 139 articles, 7 studies with 10 patients were included. In study-level data, 2/4 (50.0%) DBS studies found no improvement in dystonia and 3/3 (100%) on baclofen found decreased dystonia and enteral medication regimen. In the IPD analysis, four studies with 5 patients (2 IVB, 2 DBS, 1 ITB) were included. The average percent reduction in dystonia was 29.9% ± 32.5% (median:18%, IQR:18%-29.2%). Function improved in 4 (80.0%) patients. All patients with reported changes in enteral dystonia-related medication regimen (3/3, 100%) reported reduction in medication usage. No patients (0%) had perioperative complications. Mean follow-up length was 14.8 ± 12.2 months. No interventional clinical trials were found. ITB, IVB, and DBS represent present neuromodulatory approaches for the treatment of GA1. ITB and IVB reduce dystonia, while DBS has a heterogeneous effect. ITB and IVB improved function and reduced enteral medication regimens. These findings must be viewed with caution considering limited data and a serious risk of bias. Further large-scale studies are necessary to determine indications for ITB, IVB, and DBS and elucidate treatment algorithms.
Collapse
Affiliation(s)
- Nathan A Shlobin
- Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Katherine Hofmann
- Deparment of Neurosurgery, Children's National Hospital, Washington, DC, USA
| | - Robert F Keating
- Deparment of Neurosurgery, Children's National Hospital, Washington, DC, USA
| | - Chima O Oluigbo
- Deparment of Neurosurgery, Children's National Hospital, Washington, DC, USA
| |
Collapse
|
7
|
Meng H, Wei JH, Yu PZ, Ren JX, Tang MY, Sun JY, Yan XY, Su J. Insights into Advanced Neurological Dysfunction Mechanisms Following DBS Surgery in Parkinson's Patients: Neuroinflammation and Pyroptosis. Curr Issues Mol Biol 2023; 45:4480-4494. [PMID: 37232753 DOI: 10.3390/cimb45050284] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 05/17/2023] [Accepted: 05/17/2023] [Indexed: 05/27/2023] Open
Abstract
Parkinson's disease is a severe neurodegenerative disorder. Currently, deep brain electrical stimulation (DBS) is the first line of surgical treatment. However, serious neurological impairments such as speech disorders, disturbances of consciousness, and depression after surgery limit the efficacy of treatment. In this review, we summarize the recent experimental and clinical studies that have explored the possible causes of neurological deficits after DBS. Furthermore, we tried to identify clues from oxidative stress and pathological changes in patients that could lead to the activation of microglia and astrocytes in DBS surgical injury. Notably, reliable evidence supports the idea that neuroinflammation is caused by microglia and astrocytes, which may contribute to caspase-1 pathway-mediated neuronal pyroptosis. Finally, existing drugs and treatments may partially ameliorate the loss of neurological function in patients following DBS surgery by exerting neuroprotective effects.
Collapse
Affiliation(s)
- Hao Meng
- Department of Pathophysiology, College of Basic Medical Sciences, Jilin University, 126 Xinmin Street, Changchun 130021, China
| | - Jia-Hang Wei
- Department of Pathophysiology, College of Basic Medical Sciences, Jilin University, 126 Xinmin Street, Changchun 130021, China
| | - Peng-Zheng Yu
- Department of Pathophysiology, College of Basic Medical Sciences, Jilin University, 126 Xinmin Street, Changchun 130021, China
| | - Jia-Xin Ren
- Department of Pathophysiology, College of Basic Medical Sciences, Jilin University, 126 Xinmin Street, Changchun 130021, China
| | - Meng-Yao Tang
- Department of Pathophysiology, College of Basic Medical Sciences, Jilin University, 126 Xinmin Street, Changchun 130021, China
| | - Jun-Yi Sun
- Department of Pathophysiology, College of Basic Medical Sciences, Jilin University, 126 Xinmin Street, Changchun 130021, China
| | - Xiao-Yu Yan
- Department of Pathophysiology, College of Basic Medical Sciences, Jilin University, 126 Xinmin Street, Changchun 130021, China
| | - Jing Su
- Department of Pathophysiology, College of Basic Medical Sciences, Jilin University, 126 Xinmin Street, Changchun 130021, China
| |
Collapse
|
8
|
Rasiah NP, Maheshwary R, Kwon CS, Bloomstein JD, Girgis F. Complications of Deep Brain Stimulation for Parkinson Disease and Relationship between Micro-electrode tracks and hemorrhage: Systematic Review and Meta-Analysis. World Neurosurg 2023; 171:e8-e23. [PMID: 36244666 DOI: 10.1016/j.wneu.2022.10.034] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Accepted: 10/09/2022] [Indexed: 11/07/2022]
Abstract
BACKGROUND Deep brain stimulation is a common treatment for Parkinson's disease (PD). Despite strong efficacy in well-selected patients, complications can occur. Intraoperative micro-electrode recording (MER) can enhance efficacy by improving lead accuracy. However, there is controversy as to whether MER increases risk of hemorrhage. OBJECTIVES To provide a comprehensive systematic review and meta-analysis reporting complication rates from deep brain stimulation in PD. We also interrogate the association between hemorrhage and MER. METHODS The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were implemented while querying the Pubmed, Embase, and Cochrane databases. All included studies were randomized controlled trials and prospective case series with 5 or more patients. Primary outcomes included rates of overall revision, infection, lead malposition, surgical site and wound complications, hardware-related complications, and seizure. The secondary outcome was the relationship between number of MER tracks and hemorrhage rate. RESULTS 262 articles with 21,261 patients were included in the analysis. Mean follow-up was 25.8 months (range 0-133). Complication rates were: revision 4.9%, infection 4.2%, lead malposition 3.3%, surgical site complications 2.8%, hemorrhage 2.4%, hardware-related complications 2.4%, and seizure 1.9%. While hemorrhage rate did not increase with single-track MER (odds ratio, 3.49; P = 0.29), there was a significant non-linear increase with each additional track. CONCLUSION Infection and lead malposition were the most common complications. Hemorrhage risk increases with more than one MER track. These results highlight the challenge of balancing surgical accuracy and perioperative risk.
Collapse
Affiliation(s)
- Neilen P Rasiah
- Department of Neurosurgery, Cumming School of Medicine, University of Calgary, Alberta, USA
| | - Romir Maheshwary
- Department of Neurosurgery, University of California Davis School of Medicine, Sacramento, California, USA
| | - Churl-Su Kwon
- Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Joshua D Bloomstein
- Department of Neurosurgery, University of California Davis School of Medicine, Sacramento, California, USA
| | - Fady Girgis
- Department of Neurosurgery, Cumming School of Medicine, University of Calgary, Alberta, USA.
| |
Collapse
|
9
|
Stapińska-Syniec A, Sobstyl M, Paskal W. Skin-related complications following deep brain stimulation surgery: A single-center retrospective analysis of 525 patients who underwent DBS surgery. Clin Neurol Neurosurg 2023; 225:107571. [PMID: 36608467 DOI: 10.1016/j.clineuro.2022.107571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 10/24/2022] [Accepted: 12/18/2022] [Indexed: 12/24/2022]
Abstract
BACKGROUND Although Deep Brain Stimulation (DBS) is a safe and proven treatment modality for patients suffering from debilitating movement and neuropsychiatric disorders, it is not free from complications. Management of skin erosion and infection following DBS surgery constitutes a challenge in everyday clinical practice. OBJECTIVES Skin-related complications were evaluated in patients who underwent DBS surgery due to Parkinson's disease (PD), dystonia, essential tremor (ET), and other indications including Tourette syndrome (TS), Obsessive-Compulsive Disorder (OCD), and epilepsy. METHODS A retrospective analysis of clinical data was performed on patients who underwent DBS surgery between November 2008 and September 2021 at the Department of Neurosurgery, Institute of Psychiatry and Neurology, Warsaw. RESULTS 525 patients who underwent 927 DBS leads implantations were included in the analysis. There were 398 patients with PD, 80 with dystonia, 26 with ET, 7 with drug-resistant epilepsy, 5 with Multiple Sclerosis, 4 with Holme's or cerebellar tremor, 3 with TS, and 2 with OCD. 42 patients (8,0%) had 78 skin infection episodes. The overall level of skin erosion was 3,8% (20/525 patients). The risk of developing infection episode was connected with younger age at diagnosis (p = 0.017) and at surgery (p = 0.023), whereas the development of skin erosion was connected with the dystonia diagnosis (p = 0.012). Patients with dystonia showed the highest rate of infections and erosions (11/70 and 7/70 patients retrospectively). DISCUSSION Postoperative skin complications are a serious side effect of DBS surgery. CONCLUSION Our study suggests that dystonic patients are at higher risk of developing skin-related complications after DBS surgery.
Collapse
Affiliation(s)
| | - Michał Sobstyl
- Department of Neurosurgery, Institute of Psychiatry and Neurology, Warsaw, Poland
| | - Wiktor Paskal
- Department of Methodology, Laboratory of Center for Preclinical Research, Medical University of Warsaw, Warsaw, Poland
| |
Collapse
|
10
|
Jakobs M, Hajiabadi MM, Aguirre-Padilla DH, Giaccobe P, Unterberg AW, Lozano AM. Recharge PSYCH: A Study on Rechargeable Implantable Pulse Generators in Deep Brain Stimulation for Psychiatric Disorders. World Neurosurg 2023; 170:e331-e339. [PMID: 36368453 DOI: 10.1016/j.wneu.2022.11.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Accepted: 11/05/2022] [Indexed: 11/11/2022]
Abstract
BACKGROUND Rechargeable implantable pulse generators (r-IPGs) for deep brain stimulation (DBS) promise longer battery life and fewer replacement surgeries versus non-rechargeable systems. Long-term data on the effects of recharging in patients who received DBS for psychiatric indications is limited. The Recharge PSYCH trial is the first study that included DBS patients with psychiatric disorders treated with different r-IPG models. METHODS Standardized questionnaires were sent to all psychiatric DBS patients with an r-IPG implanted at the time of the study. The primary endpoint was convenience of recharging. Secondary endpoints were rate of user confidence and rate of usage-related complications, as well as charge burden (defined as minutes per week needed to recharge). RESULTS Data sets of n = 21 patients were eligible for data analysis. At the time of the survey patients were implanted with the r-IPG for a mean 31.8 ± 22.4 months. Prior to being implanted with an r-IPG, patients had undergone a median of 3 IPG replacements. The overall convenience of the charging process was rated as "easy" with a median of 8.0 out of 10.0 points. 33.3% of patients experienced situations in which the device could not be successfully recharged. In 38.1% of patients, therapy with the r-IPG was interrupted unintentionally. The average charge burden was 286 ± 22.4 minutes per week. CONCLUSIONS Patients with psychiatric disorders rated the recharging process as "easy", but with a significantly higher charge burden and usage-related complication rates compared to published data on movement disorder DBS patients.
Collapse
Affiliation(s)
- Martin Jakobs
- Division of Neurosurgery, Department of Surgery, University Health Network, University of Toronto, Toronto, Ontario, Canada; Department of Neurosurgery, University Hospital Heidelberg, Heidelberg, Germany; Division of Stereotactic Neurosurgery, Department of Neurosurgery, University Hospital Heidelberg, Heidelberg, Germany.
| | - Mohammad Mehdi Hajiabadi
- Department of Neurosurgery, University Hospital Heidelberg, Heidelberg, Germany; Division of Stereotactic Neurosurgery, Department of Neurosurgery, University Hospital Heidelberg, Heidelberg, Germany; Division of Operative Pain Department, Department of Neurosurgery, University Hospital Heidelberg, Heidelberg, Germany
| | - David Hernán Aguirre-Padilla
- Division of Neurosurgery, Department of Surgery, University Health Network, University of Toronto, Toronto, Ontario, Canada; Department of Neurology and Neurosurgery, University of Chile, Santiago de Chile, Chile
| | - Peter Giaccobe
- Department of Psychiatry, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - Andreas W Unterberg
- Department of Neurosurgery, University Hospital Heidelberg, Heidelberg, Germany
| | - Andres M Lozano
- Division of Neurosurgery, Department of Surgery, University Health Network, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
11
|
Evaluation of Deep Brain Stimulation (DBS) Lead Biomechanical Interaction with Brain Tissue. Ann Biomed Eng 2023; 51:88-102. [PMID: 36094763 DOI: 10.1007/s10439-022-03044-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 08/03/2022] [Indexed: 01/13/2023]
Abstract
The current study aims to examine the effect of material properties on implanted leads used for deep brain stimulation (DBS) using finite element (FE) analysis to investigate brain deformation around an implanted DBS lead in response to daily head accelerations. FE analysis was used to characterize the relative motion of the DBS lead in a suite of fifteen cases sampled from a previously derived kinematic envelope representative of everyday activities describing translational and rotational pulse shape, magnitude, and duration. Load curves were applied to the atlas-based brain model (ABM) with a scaled Haversine acceleration pulse in four directions of rotation: + X, - Y, + Y, and + Z. In addition to the fifteen sampled cases, six experimental cases taken from a previous literature review were also simulated for comparison. The current investigation found that there was very little difference in brain response for the DBS leads with two different material properties. In general, the brain and DBS lead experienced the greatest deformation during rotation about the Z axis for similar load cases. In conclusion, this study showed that there was no significant difference in implanted DBS lead deformation based on lead material properties.
Collapse
|
12
|
Bex A, Bex V, Carpentier A, Mathon B. Therapeutic ultrasound: The future of epilepsy surgery? Rev Neurol (Paris) 2022; 178:1055-1065. [PMID: 35853776 DOI: 10.1016/j.neurol.2022.03.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 03/08/2022] [Accepted: 03/08/2022] [Indexed: 02/08/2023]
Abstract
Epilepsy is one of the leading neurological diseases in both adults and children and in spite of advancement in medical treatment, 20 to 30% of patients remain refractory to current medical treatment. Medically intractable epilepsy has a real impact on a patient's quality of life, neurologic morbidity and even mortality. Actual therapy options are an increase in drug dosage, radiosurgery, resective surgery and non-resective neuromodulatory treatments (deep brain stimulation, vagus nerve stimulation). Resective, thermoablative or neuromodulatory surgery in the treatment of epilepsy are invasive procedures, sometimes requiring long stay-in for the patients, risks of permanent neurological deficit, general anesthesia and other potential surgery-related complications such as a hemorrhage or an infection. Radiosurgical approaches can trigger radiation necrosis, brain oedema and transient worsening of epilepsy. With technology-driven developments and pursuit of minimally invasive neurosurgery, transcranial MR-guided focused ultrasound has become a valuable treatment for neurological diseases. In this critical review, we aim to give the reader a better understanding of current advancement for ultrasound in the treatment of epilepsy. By outlining the current understanding gained from both preclinical and clinical studies, this article explores the different mechanisms and potential applications (thermoablation, blood brain barrier disruption for drug delivery, neuromodulation and cortical stimulation) of high and low intensity ultrasound and compares the various possibilities available to patients with intractable epilepsy. Technical limitations of therapeutic ultrasound for epilepsy surgery are also detailed and discussed.
Collapse
Affiliation(s)
- A Bex
- Department of Neurosurgery, CHR Citadelle, Liege, Belgium; Department of Neurosurgery, Sorbonne University, AP-HP, La Pitié-Salpêtrière Hospital, 75013, Paris, France
| | - V Bex
- Department of Neurosurgery, CHR Citadelle, Liege, Belgium
| | - A Carpentier
- Department of Neurosurgery, Sorbonne University, AP-HP, La Pitié-Salpêtrière Hospital, 75013, Paris, France; Sorbonne University, GRC 23, Brain Machine Interface, AP-HP, La Pitié-Salpêtrière Hospital, 75013 Paris, France; Sorbonne University, Advanced Surgical Research Technology Lab, Paris, France
| | - B Mathon
- Department of Neurosurgery, Sorbonne University, AP-HP, La Pitié-Salpêtrière Hospital, 75013, Paris, France; Sorbonne University, GRC 23, Brain Machine Interface, AP-HP, La Pitié-Salpêtrière Hospital, 75013 Paris, France; Sorbonne University, Advanced Surgical Research Technology Lab, Paris, France; Paris Brain Institute, ICM, Inserm U 1127, CNRS UMR 7225, Sorbonne University, UMRS, 1127 Paris, France.
| |
Collapse
|
13
|
Del Bene M, Carone G, Porto E, Barbotti A, Messina G, Tringali G, Rossi D, Lanteri P, Togni R, Demichelis G, Aquino D, Doniselli FM, DiMeco F, Casali C. Neurophysiology-Guided Laser Interstitial Thermal Therapy: A Synergistic Approach For Motor Function Preservation. Technical Note. World Neurosurg 2022; 168:165-172. [DOI: 10.1016/j.wneu.2022.09.121] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 09/26/2022] [Accepted: 09/27/2022] [Indexed: 11/22/2022]
|
14
|
Gelineau-Morel R, Kruer MC, Garris JF, Libdeh AA, Barbosa DAN, Coffman KA, Moon D, Barton C, Vera AZ, Bruce AB, Larsh T, Wu SW, Gilbert DL, O’Malley JA. Deep Brain Stimulation for Pediatric Dystonia: A Review of the Literature and Suggested Programming Algorithm. J Child Neurol 2022; 37:813-824. [PMID: 36053123 PMCID: PMC9912476 DOI: 10.1177/08830738221115248] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Deep brain stimulation (DBS) is an established intervention for use in pediatric movement disorders, especially dystonia. Although multiple publications have provided guidelines for deep brain stimulation patient selection and programming in adults, there are no evidence-based or consensus statements published for pediatrics. The result is lack of standardized care and underutilization of this effective treatment. To this end, we assembled a focus group of 13 pediatric movement disorder specialists and 1 neurosurgeon experienced in pediatric deep brain stimulation to review recent literature and current practices and propose a standardized approach to candidate selection, implantation target site selection, and programming algorithms. For pediatric dystonia, we provide algorithms for (1) programming for initial session and follow-up sessions, and (2) troubleshooting side effects encountered during programming. We discuss common side effects, how they present, and recommendations for management. This topical review serves as a resource for movement disorders specialists interested in using deep brain stimulation for pediatric dystonia.
Collapse
Affiliation(s)
- Rose Gelineau-Morel
- Division of Neurology, Department of Pediatrics, Children’s Mercy Hospital, University of Missouri-Kansas City School of Medicine, 2401 Gillham Road, Kansas City, Missouri, 64108
| | - Michael C Kruer
- Pediatric Movement Disorders Program, Barrow Neurological Institute, Phoenix Children’s Hospital & University of Arizona College of Medicine - Phoenix, Phoenix, AZ, 85016
| | - Jordan F Garris
- Division of Pediatric Neurology, Department of Neurology, University of Virginia, PO Box 800394, Charlottesville, VA, 22908−0394
| | - Amal Abu Libdeh
- Division of Pediatric Neurology, Department of Neurology, University of Virginia, PO Box 800394, Charlottesville, VA, 22908−0394
| | - Daniel A N Barbosa
- Department of Neurosurgery, Stanford University School of Medicine, 300 Pasteur Drive, Edwards Bldg, Stanford, CA, 94305
| | - Keith A Coffman
- Division of Neurology, Department of Pediatrics, Children’s Mercy Hospital, University of Missouri-Kansas City School of Medicine, 2401 Gillham Road, Kansas City, Missouri, 64108
| | - David Moon
- Department of Child Neurology, Division of Neurosciences, Helen DeVos Children’s Hospital, 100 Michigan St NE, Grand Rapids, MI 49503
| | - Christopher Barton
- Department of Neurology, University of Louisville School of Medicine, Louisville, Kentucky; Division of Child Neurology, Norton Children’s Medical Group, 231 E Chestnut St, Louisville, KY 40202
| | - Alonso Zea Vera
- Department of Neurology, Children’s National Hospital, 111 Michigan Ave NW, Washington, DC, 20010
| | - Adrienne B Bruce
- Division of Pediatric Neurology, Department of Pediatrics, Prisma Health, 200 Patewood Drive A350, Greenville, SC, USA 29615; University of South Carolina School of Medicine Greenville, 607 Grove Road, Greenville, SC, 29605
| | - Travis Larsh
- Division of Neurology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH; Department of Pediatrics, University of Cincinnati, 3333 Burnet Ave, Location E4, Suite 110, Cincinnati, OH 45229
| | - Steve W Wu
- Division of Neurology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH; Department of Pediatrics, University of Cincinnati, 3333 Burnet Ave, Location E4, Suite 110, Cincinnati, OH 45229
| | - Donald L Gilbert
- Division of Neurology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH; Department of Pediatrics, University of Cincinnati, 3333 Burnet Ave, Location E4, Suite 110, Cincinnati, OH 45229
| | - Jennifer A O’Malley
- Department of Neurology, Division of Child Neurology, Stanford University School of Medicine, 750 Welch Road, Suite 317, Palo Alto, California, 94304
| |
Collapse
|
15
|
Moser M, Chitta S, O'Brien PF, Caras A, Holloway KL. Recrudescent infection after deep brain stimulator reimplantation. J Neurosurg 2022; 137:1145-1152. [PMID: 35090130 DOI: 10.3171/2021.11.jns211425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Accepted: 11/15/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The efficacy of deep brain stimulation (DBS) in treating the symptoms of movement disorders can be life changing for patients. Thus, the 5%-15% incidence of stimulator-related infection requiring removal of the device can be particularly disheartening. Although DBS system reimplantation is generally successful, this is not always the case. The literature is replete with publications describing the incidence of infection and the associated features. However, the literature is sparse in terms of information on the incidence of recurrent or recrudescent infection after system reimplantation. The goal of this paper was to evaluate factors leading to unsuccessful reimplantation of a DBS system following initial infection. METHODS Data were reviewed for all DBS procedures performed by one surgeon (K.L.H.) over 19 years including the infectious agent, location of infection, treatment regimen, and subsequent reimplantation of a DBS system and long-term outcome. RESULTS In this series of 558 patients who had undergone DBS surgery, 37 (6.6%) subsequently developed an infection. Infections with methicillin-sensitive Staphylococcus aureus, Enterobacter species, or coagulase-negative staphylococci were predominant. Four patients had cerebritis, one had meningitis, and the rest had soft tissue infections of the pocket or scalp. All had their entire DBS system explanted, followed by 4-6 weeks of intravenous antibiotics and surveillance for recrudescence for an additional period of at least 30 days. Twenty-five patients subsequently underwent DBS system reimplantation, and the procedure was successful in 22. Three of the 4 patients with cerebritis developed a subsequent wound infection after system reimplantation. None of the other 22 patients developed a recurrence. The odds ratio for developing a recurrent infection after cerebritis was 28.5 (95% CI 1.931-420.5, p = 0.007). CONCLUSIONS This study, the largest series of DBS system reimplantations following infection, demonstrated that most patients can have successful reimplantations without recurrent infection. However, patients who have had DBS-related cerebritis have a nearly 30-fold increased risk of developing reinfection after reimplantation. Alternative strategies for these patients are discussed.
Collapse
|
16
|
Runge J, Nagel JM, Cassini Ascencao L, Blahak C, Kinfe TM, Schrader C, Wolf ME, Saryyeva A, Krauss JK. Are Transventricular Approaches Associated With Increased Hemorrhage? A Comparative Study in a Series of 624 Deep Brain Stimulation Surgeries. Oper Neurosurg (Hagerstown) 2022; 23:e108-e113. [PMID: 35838461 DOI: 10.1227/ons.0000000000000275] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Accepted: 03/06/2022] [Indexed: 01/17/2023] Open
Abstract
BACKGROUND Deep brain stimulation (DBS) surgery has advanced tremendously, for both clinical applications and technology. Although DBS surgery is an overall safe procedure, rare side effects, in particular, hemorrhage, may result in devastating consequences. Although there are certain advantages with transventricular trajectories, it has been reasoned that avoidance of such trajectories would likely reduce hemorrhage. OBJECTIVE To investigate the possible impact of a transventricular trajectory as compared with a transcerebral approach on the occurrence of symptomatic and asymptomatic hemorrhage after DBS electrode placement. METHODS Retrospective evaluation of 624 DBS surgeries in 582 patients, who underwent DBS surgery for movement disorders, chronic pain, or psychiatric disorders. A stereotactic guiding cannula was routinely used for DBS electrode insertion. All patients had postoperative computed tomography scans within 24 hours after surgery. RESULTS Transventricular transgression was identified in 404/624 DBS surgeries. The frequency of hemorrhage was slightly higher in transventricular than in transcerebral DBS surgeries (15/404, 3.7% vs 6/220, 2.7%). While 7/15 patients in the transventricular DBS surgery group had a hemorrhage located in the ventricle, 6 had an intracerebral hemorrhage along the electrode trajectory unrelated to transgression of the ventricle and 2 had a subdural hematoma. Among the 7 patients with a hemorrhage located in the ventricle, only one became symptomatic. Overall, a total of 7/404 patients in the transventricular DBS surgery group had a symptomatic hemorrhage, whereas the hemorrhage remained asymptomatic in all 6/220 patients in the transcerebral DBS surgery group. CONCLUSION Transventricular approaches in DBS surgery can be performed safely, in general, when special precautions such as using a guiding cannula are routinely applied.
Collapse
Affiliation(s)
- Joachim Runge
- Department of Neurosurgery, Hannover Medical School, Hannover, Germany
| | - Johanna M Nagel
- Department of Neurosurgery, Hannover Medical School, Hannover, Germany
| | | | - Christian Blahak
- Department of Neurology, Clinic Lahr, Lahr, Germany.,Department of Neurology, Universitätsmedizin Mannheim, University of Heidelberg, Mannheim, Germany
| | - Thomas M Kinfe
- Division of Functional Neurosurgery and Stereotaxy, Department of Neurosurgery, Friedrich-Alexander University, Erlangen-Nürnberg, Germany
| | | | - Marc E Wolf
- Department of Neurology, Universitätsmedizin Mannheim, University of Heidelberg, Mannheim, Germany.,Department of Neurology, Katharinenhospital Stuttgart, Stuttgart, Germany
| | - Assel Saryyeva
- Department of Neurosurgery, Hannover Medical School, Hannover, Germany
| | - Joachim K Krauss
- Department of Neurosurgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|
17
|
Raoul S, Brissot R, Lefaucheur JP, Nguyen JM, Rouaud T, Meas Y, Huchet A, Razafimahefa N, Damier P, Nizard J, Nguyen JP. Additional Benefit of Intraoperative Electroacupuncture in Improving Tolerance of Deep Brain Stimulation Surgical Procedure in Parkinsonian Patients. J Clin Med 2022; 11:jcm11102680. [PMID: 35628808 PMCID: PMC9145270 DOI: 10.3390/jcm11102680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 04/25/2022] [Accepted: 05/07/2022] [Indexed: 02/04/2023] Open
Abstract
Background: Deep brain stimulation (DBS) is an effective technique to treat patients with advanced Parkinson’s disease. The surgical procedure of DBS implantation is generally performed under local anesthesia due to the need for intraoperative clinical testing. However, this procedure is long (5–7 h on average) and, therefore, the objective that the patient remains co-operative and tolerates the intervention well is a real challenge. Objective: To evaluate the additional benefit of electroacupuncture (EA) performed intraoperatively to improve the comfort of parkinsonian patients during surgical DBS implantation. Methods: This single-center randomized study compared two groups of patients. In the first group, DBS implantation was performed under local anesthesia alone, while the second group received EA in addition. The patients were evaluated preoperatively, during the different stages of the surgery, and 2 days after surgery, using the 9-item Edmonton Symptom Assessment System (ESAS), including a total sum score and physical and emotional subscores. Results: The data of nine patients were analyzed in each group. Although pain and tiredness increased in both groups after placement of the stereotactic frame, the ESAS item “lack of appetite”, as well as the ESAS total score and physical subscore increased after completion of the first burr hole until the end of the surgical procedure in the control group only. ESAS total score and physical subscore were significantly higher at the end of the intervention in the control group compared to the EA group. After the surgical intervention (D2), anxiety and ESAS emotional subscore were improved in both groups, but the feeling of wellbeing improved in the EA group only. Finally, one patient developed delirium during the intervention and none in the EA group. Discussion: This study shows that intraoperative electroacupuncture significantly improves the tolerance of DBS surgery in parkinsonian patients. This easy-to-perform procedure could be fruitfully added in clinical practice.
Collapse
Affiliation(s)
- Sylvie Raoul
- Service de Neurochirurgie, Hôpital Laennec, CHU, 44093 Nantes, France; (R.B.); (N.R.)
- Correspondence: ; Tel.: +33-240165080
| | - Régine Brissot
- Service de Neurochirurgie, Hôpital Laennec, CHU, 44093 Nantes, France; (R.B.); (N.R.)
| | - Jean-Pascal Lefaucheur
- EA4391, Excitabilité Nerveuse et Thérapeutique, Université Paris Est Créteil, 94000 Créteil, France; (J.-P.L.); (J.N.)
- Unité de Neurophysiologie Clinique, Hôpital Henri Mondor, AP-HP, 94000 Créteil, France
| | - Jean-Michel Nguyen
- Service de Biostatistiques et d’épidémiologie, Hôpital Saint Jacques, CHU, 44093 Nantes, France;
| | - Tiphaine Rouaud
- Service de Neurologie, Hôpital Laennec, CHU, 44093 Nantes, France; (T.R.); (P.D.)
| | - Yunsan Meas
- Service Douleur, Soins palliatifs et de Support et UIC22, Hôpital Laennec, CHU, 44093 Nantes, France; (Y.M.); (J.-P.N.)
| | | | | | - Philippe Damier
- Service de Neurologie, Hôpital Laennec, CHU, 44093 Nantes, France; (T.R.); (P.D.)
| | - Julien Nizard
- EA4391, Excitabilité Nerveuse et Thérapeutique, Université Paris Est Créteil, 94000 Créteil, France; (J.-P.L.); (J.N.)
- Service Douleur, Soins palliatifs et de Support et UIC22, Hôpital Laennec, CHU, 44093 Nantes, France; (Y.M.); (J.-P.N.)
| | - Jean-Paul Nguyen
- Service Douleur, Soins palliatifs et de Support et UIC22, Hôpital Laennec, CHU, 44093 Nantes, France; (Y.M.); (J.-P.N.)
- Centre D’évaluation et de Traitement de la Douleur, Clinique Brétéché, Groupe Elsan, 44000 Nantes, France
| |
Collapse
|
18
|
Abstract
Temporal lobe epilepsy (TLE) is the most common cause of refractory epilepsy amenable for surgical treatment and seizure control. Surgery for TLE is a safe and effective strategy. The seizure-free rate after surgical resection in patients with mesial or neocortical TLE is about 70%. Resective surgery has an advantage over stereotactic radiosurgery in terms of seizure outcomes for mesial TLE patients. Both techniques have similar results for safety, cognitive outcomes, and associated costs. Stereotactic radiosurgery should therefore be seen as an alternative to open surgery for patients with contraindications for or with reluctance to undergo open surgery. Laser interstitial thermal therapy (LITT) has also shown promising results as a curative technique in mesial TLE but needs to be more deeply evaluated. Brain-responsive stimulation represents a palliative treatment option for patients with unilateral or bilateral MTLE who are not candidates for temporal lobectomy or who have failed a prior mesial temporal lobe resection. Overall, despite the expansion of innovative techniques in recent years, resective surgery remains the reference treatment for TLE and should be proposed as the first-line surgical modality. In the future, ultrasound therapies could become a credible therapeutic option for refractory TLE patients.
Collapse
Affiliation(s)
- Bertrand Mathon
- Department of Neurosurgery, La Pitié-Salpêtrière University Hospital, Paris, France; Sorbonne University, Paris, France; Paris Brain Institute, Paris, France
| | - Stéphane Clemenceau
- Department of Neurosurgery, La Pitié-Salpêtrière University Hospital, Paris, France
| |
Collapse
|
19
|
Cho KW, Sunwoo SH, Hong YJ, Koo JH, Kim JH, Baik S, Hyeon T, Kim DH. Soft Bioelectronics Based on Nanomaterials. Chem Rev 2021; 122:5068-5143. [PMID: 34962131 DOI: 10.1021/acs.chemrev.1c00531] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Recent advances in nanostructured materials and unconventional device designs have transformed the bioelectronics from a rigid and bulky form into a soft and ultrathin form and brought enormous advantages to the bioelectronics. For example, mechanical deformability of the soft bioelectronics and thus its conformal contact onto soft curved organs such as brain, heart, and skin have allowed researchers to measure high-quality biosignals, deliver real-time feedback treatments, and lower long-term side-effects in vivo. Here, we review various materials, fabrication methods, and device strategies for flexible and stretchable electronics, especially focusing on soft biointegrated electronics using nanomaterials and their composites. First, we summarize top-down material processing and bottom-up synthesis methods of various nanomaterials. Next, we discuss state-of-the-art technologies for intrinsically stretchable nanocomposites composed of nanostructured materials incorporated in elastomers or hydrogels. We also briefly discuss unconventional device design strategies for soft bioelectronics. Then individual device components for soft bioelectronics, such as biosensing, data storage, display, therapeutic stimulation, and power supply devices, are introduced. Afterward, representative application examples of the soft bioelectronics are described. A brief summary with a discussion on remaining challenges concludes the review.
Collapse
Affiliation(s)
- Kyoung Won Cho
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,Interdisciplinary Program for Bioengineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Sung-Hyuk Sunwoo
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 08826, Republic of Korea
| | - Yongseok Joseph Hong
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 08826, Republic of Korea
| | - Ja Hoon Koo
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea
| | - Jeong Hyun Kim
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea
| | - Seungmin Baik
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 08826, Republic of Korea
| | - Taeghwan Hyeon
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,Interdisciplinary Program for Bioengineering, Seoul National University, Seoul 08826, Republic of Korea.,School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 08826, Republic of Korea
| | - Dae-Hyeong Kim
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea.,Interdisciplinary Program for Bioengineering, Seoul National University, Seoul 08826, Republic of Korea.,School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 08826, Republic of Korea.,Department of Materials Science and Engineering, Seoul National University, Seoul 08826, Republic of Korea
| |
Collapse
|
20
|
Hyakumura T, Aregueta-Robles U, Duan W, Villalobos J, Adams WK, Poole-Warren L, Fallon JB. Improving Deep Brain Stimulation Electrode Performance in vivo Through Use of Conductive Hydrogel Coatings. Front Neurosci 2021; 15:761525. [PMID: 34803592 PMCID: PMC8602793 DOI: 10.3389/fnins.2021.761525] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Accepted: 10/11/2021] [Indexed: 11/13/2022] Open
Abstract
Active implantable neurological devices like deep brain stimulators have been used over the past few decades to treat movement disorders such as those in people with Parkinson’s disease and more recently, in psychiatric conditions like obsessive compulsive disorder. Electrode-tissue interfaces that support safe and effective targeting of specific brain regions are critical to success of these devices. Development of directional electrodes that activate smaller volumes of brain tissue requires electrodes to operate safely with higher charge densities. Coatings such as conductive hydrogels (CHs) provide lower impedances and higher charge injection limits (CILs) than standard platinum electrodes and support safer application of smaller electrode sizes. The aim of this study was to examine the chronic in vivo performance of a new low swelling CH coating that supports higher safe charge densities than traditional platinum electrodes. A range of hydrogel blends were engineered and their swelling and electrical performance compared. Electrochemical performance and stability of high and low swelling formulations were compared during insertion into a model brain in vitro and the formulation with lower swelling characteristics was chosen for the in vivo study. CH-coated or uncoated Pt electrode arrays were implanted into the brains of 14 rats, and their electrochemical performance was tested weekly for 8 weeks. Tissue response and neural survival was assessed histologically following electrode array removal. CH coating resulted in significantly lower voltage transient impedance, higher CIL, lower electrochemical impedance spectroscopy, and higher charge storage capacity compared to uncoated Pt electrodes in vivo, and this advantage was maintained over the 8-week implantation. There was no significant difference in evoked potential thresholds, signal-to-noise ratio, tissue response or neural survival between CH-coated and uncoated Pt groups. The significant electrochemical advantage and stability of CH coating in the brain supports the suitability of this coating technology for future development of smaller, higher fidelity electrode arrays with higher charge density requirement.
Collapse
Affiliation(s)
- Tomoko Hyakumura
- The Bionics Institute of Australia, East Melbourne, VIC, Australia.,Department of Medical Bionics, The University of Melbourne, Parkville, VIC, Australia
| | - Ulises Aregueta-Robles
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW, Australia
| | - Wenlu Duan
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW, Australia
| | - Joel Villalobos
- The Bionics Institute of Australia, East Melbourne, VIC, Australia.,Department of Medical Bionics, The University of Melbourne, Parkville, VIC, Australia
| | - Wendy K Adams
- The Bionics Institute of Australia, East Melbourne, VIC, Australia
| | - Laura Poole-Warren
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW, Australia.,Tyree Foundation Institute of Health Engineering, The University of New South Wales, Sydney, NSW, Australia
| | - James B Fallon
- The Bionics Institute of Australia, East Melbourne, VIC, Australia.,Department of Medical Bionics, The University of Melbourne, Parkville, VIC, Australia
| |
Collapse
|
21
|
Narayanan MDK, Deora H, Garg K, Grotenhuis JA. A Comparative Scientometric Analysis of the 100 Most Cited Articles of Acta Neurochirurgica (Wien) and World Neurosurgery. World Neurosurg 2021; 157:106-122. [PMID: 34662657 DOI: 10.1016/j.wneu.2021.10.099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 10/10/2021] [Accepted: 10/11/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Acta Neurochirurgica (ANCH) and World Neurosurgery (WN), are 2 journals of significant importance in the neurosurgical community and have been associated with international federations. These journals carry a similar impact factor. The difference is the years they have been active (ANCH starting publication in 1973 and WN in 2010). This factor allows for a unique opportunity to delve deep into comparative, scientometric parameters, to understand the evolution of neurosurgical research. METHODS A title-specific search of the Web of Science database using the keywords "Acta Neurochirurgica," "Acta," "Neurochirurgica," "World Neurosurgery," "World," and "Neurosurgery" was performed and arranged according to number of citations. The title of the articles, authors, corresponding authors, country of origin, journal of publication, year of publication, citation count. and journal impact factor were assessed. RESULTS The average citation for ANCH was 170.1 citations, most being original articles (83/100). The articles of WN garnered nearly 70.48 citations, averaging 8.3 citations per publication. Most corresponding authors in ANCH originated from Germany with neuro-oncology, followed by neurotrauma and vascular as subjects. In contrast, the United States followed by China were the most common countries of origin for WN, with endoscopy and skull base being the topics achieving high impact. CONCLUSIONS Neurotrauma and consensus guidelines have been shown to have maximal citations for ANCH whereas endoscopy and skull base lesions garnered the most for WN. Author subspecialization and increased collaboration across specialties with more articles on refinement of technique and outcome have emerged as recent trends.
Collapse
Affiliation(s)
| | - Harsh Deora
- Department of Neurosurgery, National Institute of Mental Health and Neurosciences, Bengaluru, India
| | - Kanwaljeet Garg
- Department of Neurosurgery, All-India Institute of Medical Sciences, New Delhi, India.
| | | |
Collapse
|
22
|
Sarica C, Iorio-Morin C, Aguirre-Padilla DH, Najjar A, Paff M, Fomenko A, Yamamoto K, Zemmar A, Lipsman N, Ibrahim GM, Hamani C, Hodaie M, Lozano AM, Munhoz RP, Fasano A, Kalia SK. Implantable Pulse Generators for Deep Brain Stimulation: Challenges, Complications, and Strategies for Practicality and Longevity. Front Hum Neurosci 2021; 15:708481. [PMID: 34512295 PMCID: PMC8427803 DOI: 10.3389/fnhum.2021.708481] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 07/30/2021] [Indexed: 11/29/2022] Open
Abstract
Deep brain stimulation (DBS) represents an important treatment modality for movement disorders and other circuitopathies. Despite their miniaturization and increasing sophistication, DBS systems share a common set of components of which the implantable pulse generator (IPG) is the core power supply and programmable element. Here we provide an overview of key hardware and software specifications of commercially available IPG systems such as rechargeability, MRI compatibility, electrode configuration, pulse delivery, IPG case architecture, and local field potential sensing. We present evidence-based approaches to mitigate hardware complications, of which infection represents the most important factor. Strategies correlating positively with decreased complications include antibiotic impregnation and co-administration and other surgical considerations during IPG implantation such as the use of tack-up sutures and smaller profile devices.Strategies aimed at maximizing battery longevity include patient-related elements such as reliability of IPG recharging or consistency of nightly device shutoff, and device-specific such as parameter delivery, choice of lead configuration, implantation location, and careful selection of electrode materials to minimize impedance mismatch. Finally, experimental DBS systems such as ultrasound, magnetoelectric nanoparticles, and near-infrared that use extracorporeal powered neuromodulation strategies are described as potential future directions for minimally invasive treatment.
Collapse
Affiliation(s)
- Can Sarica
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada
| | - Christian Iorio-Morin
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada.,Division of Neurosurgery, Department of Surgery, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - David H Aguirre-Padilla
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada.,Department of Neurology & Neurosurgery, Center Campus, Universidad de Chile, Santiago, Chile
| | - Ahmed Najjar
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada.,Department of Surgery, College of Medicine, Taibah University, Almadinah Almunawwarah, Saudi Arabia
| | - Michelle Paff
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada.,Department of Neurosurgery, University of California, Irvine, Irvine, CA, United States
| | - Anton Fomenko
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada
| | - Kazuaki Yamamoto
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada
| | - Ajmal Zemmar
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada.,Department of Neurosurgery, Henan University School of Medicine, Zhengzhou, China.,Department of Neurosurgery, University of Louisville School of Medicine, Louisville, KY, United States
| | - Nir Lipsman
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada
| | - George M Ibrahim
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada
| | - Clement Hamani
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada.,Harquail Centre for Neuromodulation, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Mojgan Hodaie
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada.,Krembil Research Institute, University Health Network, Toronto, ON, Canada.,CRANIA Center for Advancing Neurotechnological Innovation to Application, University of Toronto, ON, Canada
| | - Andres M Lozano
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada.,Krembil Research Institute, University Health Network, Toronto, ON, Canada.,CRANIA Center for Advancing Neurotechnological Innovation to Application, University of Toronto, ON, Canada
| | - Renato P Munhoz
- Krembil Research Institute, University Health Network, Toronto, ON, Canada.,Edmond J. Safra Program in Parkinson's Disease Morton and Gloria Shulman Movement Disorders Clinic, Toronto Western Hospital, and Division of Neurology, Toronto Western Hospital, University of Toronto, Toronto, ON, Canada
| | - Alfonso Fasano
- Krembil Research Institute, University Health Network, Toronto, ON, Canada.,CRANIA Center for Advancing Neurotechnological Innovation to Application, University of Toronto, ON, Canada.,Edmond J. Safra Program in Parkinson's Disease Morton and Gloria Shulman Movement Disorders Clinic, Toronto Western Hospital, and Division of Neurology, Toronto Western Hospital, University of Toronto, Toronto, ON, Canada
| | - Suneil K Kalia
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, ON, Canada.,Krembil Research Institute, University Health Network, Toronto, ON, Canada.,CRANIA Center for Advancing Neurotechnological Innovation to Application, University of Toronto, ON, Canada.,KITE, University Health Network, Toronto, ON, Canada
| |
Collapse
|
23
|
Strotzer QD, Kohl Z, Anthofer JM, Faltermeier R, Schmidt NO, Torka E, Greenlee MW, Fellner C, Schlaier JR, Beer AL. Structural Connectivity Patterns of Side Effects Induced by Subthalamic Deep Brain Stimulation for Parkinson's Disease. Brain Connect 2021; 12:374-384. [PMID: 34210163 DOI: 10.1089/brain.2021.0051] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Background: Tractography based on diffusion-weighted magnetic resonance imaging (DWI) models the structural connectivity of the human brain. Deep brain stimulation (DBS) targeting the subthalamic nucleus is an effective treatment for advanced Parkinson's disease, but may induce adverse effects. This study investigated the relationship between structural connectivity patterns of DBS electrodes and stimulation-induced side effects. Materials and Methods: Twenty-one patients with Parkinson's disease treated with bilateral subthalamic DBS were examined. Overall, 168 electrode contacts were categorized as inducing or noninducing depending on their capability for inducing side effects such as motor effects, paresthesia, dysarthria, oculomotor effects, hyperkinesia, and other complications as assessed during the initial programming session. Furthermore, the connectivity of each contact with target regions was evaluated by probabilistic tractography based on DWI. Finally, stimulation sites and structural connectivity patterns of inducing and noninducing contacts were compared. Results: Inducing contacts differed across the various side effects and from those mitigating Parkinson's symptoms. Although contacts showed a largely overlapping spatial distribution within the subthalamic region, they could be distinguished by their connectivity patterns. In particular, inducing contacts were more likely connected with supplementary motor areas (hyperkinesia, dysarthria), frontal cortex (oculomotor), fibers of the internal capsule (paresthesia), and the basal ganglia-thalamo-cortical circuitry (dysarthria). Discussion: Side effects induced by DBS seem to be associated with distinct connectivity patterns. Cerebellar connections are hardly associated with side effects, although they seem relevant for mitigating motor symptoms in Parkinson's disease. A symptom-specific, connectivity-based approach for target planning in DBS may enhance treatment outcomes and reduce adverse effects.
Collapse
Affiliation(s)
- Quirin D Strotzer
- Department of Neurosurgery, University of Regensburg Medical Center, Regensburg, Germany.,Center for Deep Brain Stimulation, University of Regensburg Medical Center, Regensburg, Germany.,Institute of Radiology, and University of Regensburg Medical Center, Regensburg, Germany
| | - Zacharias Kohl
- Center for Deep Brain Stimulation, University of Regensburg Medical Center, Regensburg, Germany.,Department of Neurology, University of Regensburg Medical Center, Regensburg, Germany.,Department of Molecular Neurology, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
| | - Judith M Anthofer
- Department of Neurosurgery, University of Regensburg Medical Center, Regensburg, Germany.,Center for Deep Brain Stimulation, University of Regensburg Medical Center, Regensburg, Germany
| | - Rupert Faltermeier
- Department of Neurosurgery, University of Regensburg Medical Center, Regensburg, Germany
| | - Nils O Schmidt
- Department of Neurosurgery, University of Regensburg Medical Center, Regensburg, Germany
| | - Elisabeth Torka
- Center for Deep Brain Stimulation, University of Regensburg Medical Center, Regensburg, Germany.,Department of Neurology, University of Regensburg Medical Center, Regensburg, Germany
| | - Mark W Greenlee
- Institute of Psychology, University of Regensburg, Regensburg, Germany
| | - Claudia Fellner
- Institute of Radiology, and University of Regensburg Medical Center, Regensburg, Germany
| | - Juergen R Schlaier
- Department of Neurosurgery, University of Regensburg Medical Center, Regensburg, Germany.,Center for Deep Brain Stimulation, University of Regensburg Medical Center, Regensburg, Germany
| | - Anton L Beer
- Institute of Psychology, University of Regensburg, Regensburg, Germany
| |
Collapse
|
24
|
Ginalis EE, Hargreaves EL, Caputo DL, Danish SF. Is It Possible to Save the Deep Brain Stimulation Hardware when Presenting with Wound Dehiscence or Hardware Infection? Stereotact Funct Neurosurg 2021; 99:496-505. [PMID: 34289473 DOI: 10.1159/000517299] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Accepted: 05/18/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Deep brain stimulation (DBS) hardware complications have been traditionally managed by removal of the entire system. Explantation of the system results in prolonged interruption to the patient's care and potential challenges when considering reimplantation of the cranial leads. The purpose of this study was to understand whether complete explantation can be avoided for patients initially presenting with wound dehiscence and/or infection of hardware. METHODS We performed a retrospective study that included 30 cases of wound dehiscence or infection involving the DBS system. Patients underwent reoperation without explantation of the DBS system, with partial explanation, or with complete explantation as initial management of the complication. RESULTS A total of 17/30 cases were managed with hardware-sparing wound revisions. The majority presented with wound dehiscence (94%), with the scalp (n = 9) as the most common location. This was successful in 76.5% of patients (n = 13). Over 11/30 patients were managed with partial explantation. The complication was located at the generator (91%) or at the scalp (9%). Partial explantation was successful in 64% of patients (n = 7). In cases that underwent a lead-sparing approach, 33% of patients ultimately required removal of the intracranial lead, and 2/30 cases of hardware infection were managed initially with total explantation. DISCUSSION/CONCLUSION Wound dehiscence can be successfully managed without complete removal of the DBS system in most cases. In cases of infection, removing the involved component(s) and sparing the intracranial leads may be considered. Wound revision without removal of the entire DBS system is safe and can improve quality of life by preventing or shortening the withdrawal of DBS treatment.
Collapse
Affiliation(s)
- Elizabeth E Ginalis
- Department of Neurosurgery, Rutgers-Robert Wood Johnson Medical School, New Brunswick, New Jersey, USA,
| | - Eric L Hargreaves
- Department of Neurosurgery, Rutgers-Robert Wood Johnson Medical School, New Brunswick, New Jersey, USA.,Department of Neurology, Rutgers-Robert Wood Johnson Medical School, New Brunswick, New Jersey, USA
| | - Deborah L Caputo
- Department of Neurology, Rutgers-Robert Wood Johnson Medical School, New Brunswick, New Jersey, USA
| | - Shabbar F Danish
- Department of Neurosurgery, Rutgers-Robert Wood Johnson Medical School, New Brunswick, New Jersey, USA
| |
Collapse
|
25
|
Britz JPE, Franceschini PR, Ramos MB, de Aguiar PHP, Farah JO, de Aguiar PHP. Skin erosion in deep brain stimulation procedures: Using the temporalis muscle to treat this complication - A technical note. Surg Neurol Int 2021; 12:355. [PMID: 34345495 PMCID: PMC8326058 DOI: 10.25259/sni_372_2021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Accepted: 06/12/2021] [Indexed: 11/17/2022] Open
Abstract
Background: Skin erosion is a common complication after deep brain stimulator procedures. Despite being a relatively common event, there is no standard surgical technique or a widely accepted guideline for managing this kind of complication. Methods: We describe a case of cutaneous erosion in the connector’s site of deep brain stimulation case, surgically managed with anterior displacement of the connectors and overlapping and wrapping the connections within the temporal muscle. Results: Postoperatively, the patient did well and achieved complete resolution of the skin erosion, with no signs of infection or new skin lesions. Conclusion: This technique demonstrated to be effective in this case in the long-term follow-up.
Collapse
Affiliation(s)
- João Pedro Einsfeld Britz
- Department of Health Science, Medical School, University of Caxias do Sul, Caxias do Sul, Rio Grande do Sul, Brazil
| | - Paulo Roberto Franceschini
- Department of Neurology and Neurosurgery, University of Caxias do Sul, Caxias do Sul, Rio Grande do Sul, Brazil
| | - Miguel Bertelli Ramos
- Department of Health Science, Medical School, University of Caxias do Sul, Caxias do Sul, Rio Grande do Sul, Brazil
| | | | - Jibril Osman Farah
- Department of Neurosurgery, The Walton Centre, Liverpool, United Kingdom
| | | |
Collapse
|
26
|
Atchley TJ, Elsayed GA, Sowers B, Walker HC, Chagoya G, Davis MC, Bernstock JD, Omar NB, Patel DM, Guthrie BL. Incidence and risk factors for seizures associated with deep brain stimulation surgery. J Neurosurg 2021; 135:279-283. [PMID: 32764176 DOI: 10.3171/2020.5.jns20125] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Accepted: 05/11/2020] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The objective of this study was to determine the incidence of seizures following deep brain stimulation (DBS) electrode implantation and to evaluate factors associated with postoperative seizures. METHODS The authors performed a single-center retrospective case-control study. The outcome of interest was seizure associated with DBS implantation. Univariate analyses were performed using the Student t-test for parametric continuous outcomes. The authors used the Kruskal-Wallis test or Wilcoxon rank-sum test for nonparametric continuous outcomes, chi-square statistics for categorical outcomes, and multivariate logistic regression for binomial variables. RESULTS A total of 814 DBS electrode implantations were performed in 645 patients (478 [58.7%] in men and 520 [63.9%] in patients with Parkinson's disease). In total, 22 (3.4%) patients who had undergone 23 (2.8%) placements experienced seizure. Of the 23 DBS implantation-related seizures, 21 were new-onset seizures (3.3% of 645 patients) and 2 were recurrence or worsening of a prior seizure disorder. Among the 23 cases with postimplantation-related seizure, epilepsy developed in 4 (17.4%) postoperatively; the risk of DBS-associated epilepsy was 0.50% per DBS electrode placement and 0.63% per patient. Nine (39.1%) implantation-related seizures had associated postoperative radiographic abnormalities. Multivariate analyses suggested that age at surgery conferred a modest increased risk for postoperative seizures (OR 1.06, 95% CI 1.02-1.10). Sex, primary diagnosis, electrode location and sidedness, and the number of trajectories were not significantly associated with seizures after DBS surgery. CONCLUSIONS Seizures associated with DBS electrode placement are uncommon, typically occur early within the postoperative period, and seldom lead to epilepsy. This study suggests that patient characteristics, such as age, may play a greater role than perioperative variables in determining seizure risk. Multiinstitutional studies may help better define and mitigate the risk of seizures after DBS surgery.
Collapse
Affiliation(s)
| | | | - Blake Sowers
- 2University of Alabama at Birmingham School of Medicine, Birmingham, Alabama; and
| | | | | | | | - Joshua D Bernstock
- 4Department of Neurological Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
| | | | | | | |
Collapse
|
27
|
Malinova V, Jaskólski DJ, Wójcik R, Mielke D, Rohde V. Frameless x-ray-based lead re-implantation after partial hardware removal of deep brain stimulation system with preservation of intracerebral trajectories. Acta Neurochir (Wien) 2021; 163:1873-1878. [PMID: 33754181 PMCID: PMC8195963 DOI: 10.1007/s00701-021-04807-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Accepted: 03/10/2021] [Indexed: 11/26/2022]
Abstract
Background Deep brain stimulation (DBS) is an established treatment for patients with medical refractory movement disorders with continuously increasing use also in other neurological and psychiatric diseases. Early and late complications can lead to revision surgeries with partial or complete DBS-system removal. In this study, we aimed to report on our experience with a frameless x-ray-based lead re-implantation technique after partial hardware removal or dysfunction of DBS-system, allowing the preservation of intracerebral trajectories. Methods We describe a surgical procedure with complete implant removal due to infection except for the intracranial part of the electrode and with non-stereotactic electrode re-implantation. A retrospective analysis of a patient series treated using this technique was performed and the surgical outcome was evaluated including radiological and clinical parameters. Results A total of 8 DBS-patients with lead re-implantation using the frameless x-ray-based method were enrolled in the study. A revision of 14 leads was performed, whereof a successful lead re-implantation could be achieved without any problems in 10 leads (71%). In two patients (one patient with dystonia and one patient with tremor), the procedure was not successful, so we placed both leads frame-based stereotactically. Conclusions The described x-ray-based technique allows a reliable frameless electrode re-implantation after infection and electrode dysfunction and might represent an efficient alternative to frame-based procedures for lead revision making the preservation of intracerebral trajectories possible.
Collapse
Affiliation(s)
- Vesna Malinova
- Department of Neurosurgery, Georg-August-University, Robert-Koch-Straße 40, 37075, Göttingen, Germany.
| | - Dariusz J Jaskólski
- Department of Neurosurgery and Neurooncology, Barlicki University Hospital, Medical University of Lodz, Lodz, Poland
| | - Rafal Wójcik
- Department of Neurosurgery and Neurooncology, Barlicki University Hospital, Medical University of Lodz, Lodz, Poland
| | - Dorothee Mielke
- Department of Neurosurgery, Georg-August-University, Robert-Koch-Straße 40, 37075, Göttingen, Germany
| | - Veit Rohde
- Department of Neurosurgery, Georg-August-University, Robert-Koch-Straße 40, 37075, Göttingen, Germany
| |
Collapse
|
28
|
Ward M, Ahmed M, Markosian C, Ezike JZ, Agrawal R, Randhawa K, Liang Z, Abraham M, Paskhover B, Mammis A. Complications associated with deep brain stimulation for Parkinson's disease: a MAUDE study. Br J Neurosurg 2021; 35:625-628. [PMID: 34151665 DOI: 10.1080/02688697.2021.1935727] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
INTRODUCTION Deep brain stimulation (DBS) is a common surgical option for the treatment of medically refractory Parkinson's disease (PD). Manufacturer and User Facility Device Experience (MAUDE), a United States Food and Drug Administration (FDA)-compiled database of adverse event reports related to medical devices, is a public resource that can provide insight into the relative frequency of complications and patient complaints. MATERIALS AND METHODS We accessed the MAUDE database and queried for adverse reports for deep brain stimulators implanted for PD from January 1, 2009 to December 31, 2018. Complaints were classified into device malfunction, patient non-compliance, patient complaint, surgically managed complications (i.e. complications that are corrected via surgery), and death. Patient complaints were further stratified into ineffective stimulation, shock, overstimulation, battery-related problems, or pain at the pulse generator site. Surgically managed complications were classified as intraoperative complications, impedance, migration, erosion, infection, lead fracture, and lead disconnection. Each event could receive multiple classifications and subclassifications. RESULTS A total of 4,189 adverse event reports was obtained. These encompassed 2,805 patient complaints. Within this group, 797 (28%) events were classified as ineffective stimulation. There were 1,382 surgically managed complications, 104 (8%) of which were intraoperative complications, 757 (55%) documented impedance issues, 381 (28%) infections, and 413 (30%) lead-related issues. There were 53 documented deaths. CONCLUSIONS The MAUDE database has potential use as a real time monitor for elucidating the relative occurrence of complications associated with deep brain stimulation. It also allows for the analysis of device-related complications in specific patient populations. Although the database is useful in this endeavor, it requires improvements particularly in the standardization of reporting adverse events.
Collapse
Affiliation(s)
- Max Ward
- Department of Neurological Surgery, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA
| | - Mohsen Ahmed
- Department of Neurological Surgery, Rutgers New Jersey Medical School, Newark, NJ, USA
| | - Christopher Markosian
- Department of Neurological Surgery, Rutgers New Jersey Medical School, Newark, NJ, USA
| | - Judith Z Ezike
- Department of Neurological Surgery, Rutgers New Jersey Medical School, Newark, NJ, USA
| | - Rishav Agrawal
- Department of Neurological Surgery, Rutgers New Jersey Medical School, Newark, NJ, USA
| | - Karandeep Randhawa
- Department of Neurological Surgery, Rutgers New Jersey Medical School, Newark, NJ, USA
| | - Zhijia Liang
- Department of Neurosurgery, Emory University School of Medicine, Atlanta, GA, USA
| | - Mickey Abraham
- Division of Neurosurgery, University of California San Diego School of Medicine, La Jolla, CA, USA
| | - Boris Paskhover
- Department of Otolaryngology - Head and Neck Surgery, Rutgers New Jersey Medical School, Newark, NJ, USA
| | - Antonios Mammis
- Department of Neurological Surgery, Rutgers New Jersey Medical School, Newark, NJ, USA
| |
Collapse
|
29
|
Xu S, Wang W, Chen S, Wu Q, Li C, Ma X, Chen T, Li W, Xu S. Deep Brain Stimulation Complications in Patients With Parkinson's Disease and Surgical Modifications: A Single-Center Retrospective Analysis. Front Hum Neurosci 2021; 15:684895. [PMID: 34177503 PMCID: PMC8226223 DOI: 10.3389/fnhum.2021.684895] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 05/17/2021] [Indexed: 11/15/2022] Open
Abstract
Background As a complication-prone operation, deep brain stimulation (DBS) has become the first-line surgical approach for patients with advanced Parkinson’s disease (PD). This study aimed to evaluate the incidence and risk factors of DBS-associated complications. Methods We have reviewed a consecutive series of patients with PD undergoing DBS procedures to describe the type, severity, management, and outcome of postoperative complications from January 2011 to December 2018. Both univariate and multivariate analyses were performed to identify statistically significant risk factors. We also described our surgical strategies to minimize the adverse events. Results A total of 225 patients underwent 229 DBS implantation procedures (440 electrodes), of whom 20 patients experienced 23 DBS-associated complications, including ten operation-related complications and 13 hardware-related ones. Univariate analysis elucidated that comorbid medical conditions (P = 0.024), hypertension (P = 0.003), early-stage operation (P < 0.001), and unilateral electrode implantation (P = 0.029) as risk factors for overall complications, or more specifically, operation-related complications demonstrated in the stratified analysis. In contrast, no risk factor for hardware-related complications was identified. Statistical significances of hypertension (OR = 3.33, 95% CI: 1.14–9.71, P = 0.027) and early-stage (OR = 11.04, 95% CI: 2.42–50.45, P = 0.002) were further validated via multivariate analysis. As the annual number of DBS procedures increased, the incidence of complications gradually decreased (R = −0.699, P < 0.01). Additionally, there was a strong correlation between surgical complications and unplanned readmission (R = 0.730, P < 0.01). Conclusion The importance of cumulative experience and relevant technique modifications should be addressed to prevent DBS-associated complications and unplanned readmission.
Collapse
Affiliation(s)
- Shuo Xu
- Department of Neurosurgery, Qilu Hospital of Shandong University and Institute of Brain and Brain-Inspired Science, Shandong University, Jinan, China.,Key Laboratory of Brain Function Remodeling, Qilu Hospital of Shandong University, Jinan, China
| | - Wenfei Wang
- Humanistic Medicine Research Center, Qilu Hospital of Shandong University, Jinan, China
| | - Si Chen
- Department of Neurosurgery, Qilu Hospital of Shandong University and Institute of Brain and Brain-Inspired Science, Shandong University, Jinan, China.,Key Laboratory of Brain Function Remodeling, Qilu Hospital of Shandong University, Jinan, China
| | - Qianqian Wu
- Department of Neurosurgery, Qilu Hospital of Shandong University and Institute of Brain and Brain-Inspired Science, Shandong University, Jinan, China.,Key Laboratory of Brain Function Remodeling, Qilu Hospital of Shandong University, Jinan, China
| | - Chao Li
- Department of Neurosurgery, Qilu Hospital of Shandong University and Institute of Brain and Brain-Inspired Science, Shandong University, Jinan, China.,Key Laboratory of Brain Function Remodeling, Qilu Hospital of Shandong University, Jinan, China
| | - Xiangyu Ma
- Department of Neurosurgery, Qilu Hospital of Shandong University and Institute of Brain and Brain-Inspired Science, Shandong University, Jinan, China.,Key Laboratory of Brain Function Remodeling, Qilu Hospital of Shandong University, Jinan, China
| | - Teng Chen
- Department of Neurosurgery, Qilu Hospital of Shandong University and Institute of Brain and Brain-Inspired Science, Shandong University, Jinan, China.,Key Laboratory of Brain Function Remodeling, Qilu Hospital of Shandong University, Jinan, China
| | - Weiguo Li
- Department of Neurosurgery, Qilu Hospital of Shandong University and Institute of Brain and Brain-Inspired Science, Shandong University, Jinan, China.,Key Laboratory of Brain Function Remodeling, Qilu Hospital of Shandong University, Jinan, China
| | - Shujun Xu
- Department of Neurosurgery, Qilu Hospital of Shandong University and Institute of Brain and Brain-Inspired Science, Shandong University, Jinan, China.,Key Laboratory of Brain Function Remodeling, Qilu Hospital of Shandong University, Jinan, China
| |
Collapse
|
30
|
Doshi PK, Rai N, Das D. Surgical and Hardware Complications of Deep Brain Stimulation-A Single Surgeon Experience of 519 Cases Over 20 Years. Neuromodulation 2021; 25:895-903. [PMID: 33496063 DOI: 10.1111/ner.13360] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Revised: 11/19/2020] [Accepted: 12/21/2020] [Indexed: 01/19/2023]
Abstract
OBJECTIVE Deep brain stimulation (DBS) surgery has its own set of risks and complications. This study from a single center and a single surgeon analyzes various risk factors for complications and tries to establish if there is a learning curve effect in minimizing the complications. MATERIALS AND METHODS A retrospective analysis of 519 patients (1024 leads) who underwent DBS surgery and 232 patients who underwent implantable pulse generator replacement (IPG), by a single surgeon, between the years 1999 and 2019 was performed. Perioperative and hardware related complications were evaluated. RESULTS The follow-up period ranged from six months to 20 years. Surgery-related complications occurred in 46 (8.9%) cases which included confusion in 31 (5.98%), intracerebral hemorrhage in 7 (1.3%), vasovagal attack in 3 (0.58%), respiratory distress in 2 (0.38%), postoperative aggressiveness in 1 (0.19%), and blepharospasm in 2 (0.38%) patients. Complications related to the DBS hardware were found in 35 cases, including erosion and infection in 22 (2.95%), inaccurate lead placement or migration in 6 (0.6%) lead fracture/extension wire failure in 2 (0.26%), IPG malfunction in 2 (0.26%), and hardware discomfort in 3 (0.4%) cases. In three patients, one lead was repositioned. In cases of infection, 87% of patients had either partial or complete removal of hardware. There was no mortality. The complications were analyzed for every 100 DBS procedures. There was a significant drop in the percentage of complications in from 23% in the first 100 cases to 7% in the last 100 cases (p < 0.0001). CONCLUSION Confusion remains the most frequent operative and perioperative complication. Erosion and infection of the surgical site represents the most frequent hardware complication. DBS surgery is safe and the complication rates are acceptably low. The complication rate also decreases with cumulative years of experience, demonstrating a learning curve effect.
Collapse
Affiliation(s)
- Paresh K Doshi
- Department of Neurosurgery, Jaslok Hospital and Research Centre, Mumbai, Maharastra, India
| | - Neha Rai
- Department of Neurosurgery, Jaslok Hospital and Research Centre, Mumbai, Maharastra, India
| | - Deepak Das
- Department of Neurosurgery, Jaslok Hospital and Research Centre, Mumbai, Maharastra, India
| |
Collapse
|
31
|
Kantzanou M, Korfias S, Panourias I, Sakas DE, Karalexi MA. Deep Brain Stimulation-Related Surgical Site Infections: A Systematic Review and Meta-Analysis. Neuromodulation 2021; 24:197-211. [PMID: 33462954 DOI: 10.1111/ner.13354] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 11/23/2020] [Accepted: 12/14/2020] [Indexed: 12/17/2022]
Abstract
BACKGROUND Over the last decades, the increased use of deep brain stimulation (DBS) has raised concerns about the potential adverse health effects of the treatment. Surgical site infections (SSIs) following an elective surgery remain a major challenge for neurosurgeons. Few studies have examined the prevalence and risk factors of DBS-related complications, particularly focusing on SSIs. OBJECTIVES We systematically searched published literature, up to June 2020, with no language restrictions. MATERIALS AND METHODS Eligible were studies that examined the prevalence of DBS-related SSIs, as well as studies that examined risk and preventive factors in relation to SSIs. We extracted information on study characteristics, follow-up, exposure and outcome assessment, effect estimate and sample size. Summary odds ratios (sOR) and 95% confidence intervals (CI) were calculated from random-effects meta-analyses; heterogeneity and small-study effects were also assessed. RESULTS We identified 66 eligible studies that included 12,258 participants from 27 countries. The summary prevalence of SSIs was estimated at 5.0% (95% CI: 4.0%-6.0%) with higher rates for dystonia (6.5%), as well as for newer indications of DBS, such as epilepsy (9.5%), Tourette syndrome (5.9%) and OCD (4.5%). Similar prevalence rates were found between early-onset and late-onset hardware infections. Among risk and preventive factors, the perioperative implementation of intra-wound vancomycin was associated with statistically significantly lower risk of SSIs (sOR: 0.26, 95% CI: 0.09-0.74). Heterogeneity was nonsignificant in most meta-analyses. CONCLUSION The present study confirms the still high prevalence of SSIs, especially for newer indications of DBS and provides evidence that preventive measures, such as the implementation of topical vancomycin, seem promising in reducing the risk of DBS-related SSIs. Large clinical trials are needed to confirm the efficacy and safety of such measures.
Collapse
Affiliation(s)
- Maria Kantzanou
- Department of Hygiene, Epidemiology & Medical Statistics, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Stefanos Korfias
- Department of Neurosurgery, School of Medicine Evangelismos Hospital, National and Kapodistrian University of Athens, Athens, Greece
| | - Ioannis Panourias
- Department of Neurosurgery, Korgialenio and Mpenakio General Hospital of Athens, Red Cross, Athens, Greece
| | - Damianos E Sakas
- Department of Neurosurgery, School of Medicine Evangelismos Hospital, National and Kapodistrian University of Athens, Athens, Greece
| | - Maria A Karalexi
- Department of Hygiene, Epidemiology & Medical Statistics, Medical School, National and Kapodistrian University of Athens, Athens, Greece
| |
Collapse
|
32
|
Long term mortality of patients with Parkinson's disease treated with deep brain stimulation in a reference center. Clin Neurol Neurosurg 2021; 202:106486. [PMID: 33493881 DOI: 10.1016/j.clineuro.2021.106486] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 10/20/2020] [Accepted: 01/07/2021] [Indexed: 11/20/2022]
Abstract
INTRODUCTION Parkinson's disease (PD) is a common neurodegenerative disorder, with a higher risk of death than general population. Deep Brain Stimulation (DBS) has been used to treat PD for more than 2 decades, but few studies exist concerning mortality in this subset of patients. Our goal is to analyse mortality in PD patients treated with DBS in our centre. METHODS retrospective evaluation of clinical files of patients with PD who underwent DBS surgery consecutively between October 2002 and May 2019. RESULTS 346 patients were included in the analysis, 60 % male, with a mean age at disease onset of 48± 8 years (18-64), mean age at surgery of 60 ± 7 years (33-75), and mean disease duration until surgery of 14 ± 6 years (3-52). Mean follow-up after surgery was 7 ± 4 years (range 1-17). Overall mortality rate was 17.9 % and mean age at time of death was 71 ± 6 years. The main causes of death were pneumonia, dementia and acute myocardial infarction. In our series, male gender and disease duration until surgery were the only predictors of mortality in multivariate analysis. CONCLUSION Our study showed a long-term survival higher than previously described, and suggests that the treatment of patients with shorter disease evolution might have a survival benefit. The leading causes of death in PD patients treated with DBS seems unrelated to surgery, as the main causes of death are comparable to non-DBS patients.
Collapse
|
33
|
Menchón JM, Real E, Alonso P, Aparicio MA, Segalas C, Plans G, Luyten L, Brunfaut E, Matthijs L, Raymakers S, Bervoets C, Higueras A, Katati M, Guerrero J, Hurtado M, Prieto M, Stieglitz LH, Löffelholz G, Walther S, Pollo C, Zurowski B, Tronnier V, Kordon A, Gambini O, Ranieri R, Franzini A, Messina G, Radu-Djurfeldt D, Schechtmann G, Chen LL, Eitan R, Israel Z, Bergman H, Brelje T, Brionne TC, Conseil A, Gielen F, Schuepbach M, Nuttin B, Gabriëls L. A prospective international multi-center study on safety and efficacy of deep brain stimulation for resistant obsessive-compulsive disorder. Mol Psychiatry 2021; 26:1234-1247. [PMID: 31664175 PMCID: PMC7985042 DOI: 10.1038/s41380-019-0562-6] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Revised: 09/30/2019] [Accepted: 10/12/2019] [Indexed: 02/07/2023]
Abstract
Deep brain stimulation (DBS) has been proposed for severe, chronic, treatment-refractory obsessive-compulsive disorder (OCD) patients. Although serious adverse events can occur, only a few studies report on the safety profile of DBS for psychiatric disorders. In a prospective, open-label, interventional multi-center study, we examined the safety and efficacy of electrical stimulation in 30 patients with DBS electrodes bilaterally implanted in the anterior limb of the internal capsule. Safety, efficacy, and functionality assessments were performed at 3, 6, and 12 months post implant. An independent Clinical Events Committee classified and coded all adverse events (AEs) according to EN ISO14155:2011. All patients experienced AEs (195 in total), with the majority of these being mild (52% of all AEs) or moderate (37%). Median time to resolution was 22 days for all AEs and the etiology with the highest AE incidence was 'programming/stimulation' (in 26 patients), followed by 'New illness, injury, condition' (13 patients) and 'pre-existing condition, worsening or exacerbation' (11 patients). Sixteen patients reported a total of 36 serious AEs (eight of them in one single patient), mainly transient anxiety and affective symptoms worsening (20 SAEs). Regarding efficacy measures, Y-BOCS reduction was 42% at 12 months and the responder rate was 60%. Improvements in GAF, CGI, and EuroQol-5D index scores were also observed. In sum, although some severe AEs occurred, most AEs were mild or moderate, transient and related to programming/stimulation and tended to resolve by adjustment of stimulation. In a severely treatment-resistant population, this open-label study supports that the potential benefits outweigh the potential risks of DBS.
Collapse
Affiliation(s)
- José M. Menchón
- grid.5841.80000 0004 1937 0247Bellvitge University Hospital-IDIBELL, University of Barcelona, CIBERSAM, Barcelona, Spain
| | - Eva Real
- grid.5841.80000 0004 1937 0247Bellvitge University Hospital-IDIBELL, University of Barcelona, CIBERSAM, Barcelona, Spain
| | - Pino Alonso
- grid.5841.80000 0004 1937 0247Bellvitge University Hospital-IDIBELL, University of Barcelona, CIBERSAM, Barcelona, Spain
| | - Marco Alberto Aparicio
- grid.5841.80000 0004 1937 0247Bellvitge University Hospital-IDIBELL, University of Barcelona, CIBERSAM, Barcelona, Spain
| | - Cinto Segalas
- grid.5841.80000 0004 1937 0247Bellvitge University Hospital-IDIBELL, University of Barcelona, CIBERSAM, Barcelona, Spain
| | - Gerard Plans
- grid.5841.80000 0004 1937 0247Bellvitge University Hospital-IDIBELL, University of Barcelona, CIBERSAM, Barcelona, Spain
| | - Laura Luyten
- grid.5596.f0000 0001 0668 7884KU Leuven and/or UZ Leuven and/or UPC KU Leuven, Leuven, Belgium
| | - Els Brunfaut
- grid.5596.f0000 0001 0668 7884KU Leuven and/or UZ Leuven and/or UPC KU Leuven, Leuven, Belgium
| | - Laurean Matthijs
- grid.5596.f0000 0001 0668 7884KU Leuven and/or UZ Leuven and/or UPC KU Leuven, Leuven, Belgium
| | - Simon Raymakers
- grid.5596.f0000 0001 0668 7884KU Leuven and/or UZ Leuven and/or UPC KU Leuven, Leuven, Belgium
| | - Chris Bervoets
- grid.5596.f0000 0001 0668 7884KU Leuven and/or UZ Leuven and/or UPC KU Leuven, Leuven, Belgium
| | - Antonio Higueras
- grid.411380.f0000 0000 8771 3783Hospital Virgen de las Nieves, Granada, Spain
| | - Majed Katati
- grid.411380.f0000 0000 8771 3783Hospital Virgen de las Nieves, Granada, Spain
| | - José Guerrero
- grid.411380.f0000 0000 8771 3783Hospital Virgen de las Nieves, Granada, Spain
| | - Mariena Hurtado
- grid.411380.f0000 0000 8771 3783Hospital Virgen de las Nieves, Granada, Spain
| | - Mercedes Prieto
- grid.411380.f0000 0000 8771 3783Hospital Virgen de las Nieves, Granada, Spain
| | | | - Georg Löffelholz
- grid.411656.10000 0004 0479 0855Inselspital Bern, Bern, Switzerland
| | - Sebastian Walther
- grid.411656.10000 0004 0479 0855Inselspital Bern, Bern, Switzerland ,grid.412559.e0000 0001 0694 3235Translational Research Center, University Hospital of Psychiatry, Bern, Switzerland
| | - Claudio Pollo
- grid.411656.10000 0004 0479 0855Inselspital Bern, Bern, Switzerland
| | - Bartosz Zurowski
- grid.412468.d0000 0004 0646 2097Universitätsklinik Schleswig-Holstein, Campus Lübeck, Lübeck, Germany
| | - Volker Tronnier
- grid.412468.d0000 0004 0646 2097Universitätsklinik Schleswig-Holstein, Campus Lübeck, Lübeck, Germany
| | - Andreas Kordon
- grid.5963.9Oberbergklinik Schwarzwald, Hornberg, and Universitätsklinikum Freiburg, Klinik für Psychiatrie und Psychotherapie, Freiburg, Germany
| | - Orsola Gambini
- grid.415093.aDepartment of Health Sciences, University of Milano, San Paolo Hospital Milano, Milano, Italy
| | - Rebecca Ranieri
- grid.415093.aDepartment of Health Sciences, University of Milano, San Paolo Hospital Milano, Milano, Italy
| | - Angelo Franzini
- Fondazione IRCCS Istituto Naz Neurologico C.Besta, Milano, Italy
| | - Giuseppe Messina
- Fondazione IRCCS Istituto Naz Neurologico C.Besta, Milano, Italy
| | - Diana Radu-Djurfeldt
- grid.24381.3c0000 0000 9241 5705Psykiatri Sydvast, OCD-departement, Karolinska University Hospital-region in Huddinge, Stockholm, Sweden
| | - Gaston Schechtmann
- grid.24381.3c0000 0000 9241 5705Department of Neurosurgery, Karolinska Institutet and University Hospital, Stockholm, Sweden
| | - Long-Long Chen
- grid.24381.3c0000 0000 9241 5705Department of Neurosurgery, Karolinska Institutet and University Hospital, Stockholm, Sweden
| | - Renana Eitan
- grid.17788.310000 0001 2221 2926Psychiatry Department, Hadassah-University Hospital, Jerusalem, Israel
| | - Zvi Israel
- grid.17788.310000 0001 2221 2926Psychiatry Department, Hadassah-University Hospital, Jerusalem, Israel
| | - Hagai Bergman
- grid.17788.310000 0001 2221 2926Psychiatry Department, Hadassah-University Hospital, Jerusalem, Israel
| | - Tim Brelje
- grid.419673.e0000 0000 9545 2456Medtronic, Minneapolis, USA
| | - Thomas C. Brionne
- grid.471158.e0000 0004 0384 6386Medtronic International Trading Sàrl, Tolochenaz, Switzerland
| | - Aurélie Conseil
- grid.471158.e0000 0004 0384 6386Medtronic International Trading Sàrl, Tolochenaz, Switzerland
| | - Frans Gielen
- grid.419671.c0000 0004 1771 1765Medtronic Bakken Research Center, Maastricht, The Netherlands
| | | | - Bart Nuttin
- grid.5596.f0000 0001 0668 7884KU Leuven and/or UZ Leuven and/or UPC KU Leuven, Leuven, Belgium
| | - Loes Gabriëls
- grid.5596.f0000 0001 0668 7884KU Leuven and/or UZ Leuven and/or UPC KU Leuven, Leuven, Belgium
| |
Collapse
|
34
|
Jakobs M, Helmers AK, Synowitz M, Slotty PJ, Anthofer JM, Schlaier JR, Kloss M, Unterberg AW, Kiening KL. A multicenter, open-label, controlled trial on acceptance, convenience, and complications of rechargeable internal pulse generators for deep brain stimulation: the Multi Recharge Trial. J Neurosurg 2020; 133:821-829. [PMID: 31419794 DOI: 10.3171/2019.5.jns19360] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Accepted: 05/07/2019] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Rechargeable neurostimulators for deep brain stimulation have been available since 2008, promising longer battery life and fewer replacement surgeries compared to non-rechargeable systems. Long-term data on how recharging affects movement disorder patients are sparse. This is the first multicenter, patient-focused, industry-independent study on rechargeable neurostimulators. METHODS Four neurosurgical centers sent a questionnaire to all adult movement disorder patients with a rechargeable neurostimulator implanted at the time of the trial. The primary endpoint was the convenience of the recharging process rated on an ordinal scale from "very hard" (1) to "very easy" (5). Secondary endpoints were charge burden (time spent per week on recharging), user confidence, and complication rates. Endpoints were compared for several subgroups. RESULTS Datasets of 195 movement disorder patients (66.1% of sent questionnaires) with Parkinson's disease (PD), tremor, or dystonia were returned and included in the analysis. Patients had a mean age of 61.3 years and the device was implanted for a mean of 40.3 months. The overall convenience of recharging was rated as "easy" (4). The mean charge burden was 122 min/wk and showed a positive correlation with duration of therapy; 93.8% of users felt confident recharging the device. The rate of surgical revisions was 4.1%, and the infection rate was 2.1%. Failed recharges occurred in 8.7% of patients, and 3.6% of patients experienced an interruption of therapy because of a failed recharge. Convenience ratings by PD patients were significantly worse than ratings by dystonia patients. Caregivers recharged the device for the patient in 12.3% of cases. Patients who switched from a non-rechargeable to a rechargeable neurostimulator found recharging to be significantly less convenient at a higher charge burden than did patients whose primary implant was rechargeable. Age did not have a significant impact on any endpoint. CONCLUSIONS Overall, patients with movement disorders rated recharging as easy, with low complication rates and acceptable charge burden.
Collapse
Affiliation(s)
- Martin Jakobs
- 1Department of Neurosurgery, Division of Stereotactic Neurosurgery, and
- Departments of2Neurosurgery and
| | - Ann-Kristin Helmers
- 4Department of Neurosurgery, University Medical Center Schleswig-Holstein, Campus Kiel, Christian-Albrechts-University Kiel, Kiel
| | - Michael Synowitz
- 4Department of Neurosurgery, University Medical Center Schleswig-Holstein, Campus Kiel, Christian-Albrechts-University Kiel, Kiel
| | - Philipp J Slotty
- 5Department of Stereotactic and Functional Neurosurgery, University Hospital Düsseldorf, Heinrich-Heine University Düsseldorf, Düsseldorf; and
| | - Judith M Anthofer
- 6Department of Neurosurgery, University Hospital Regensburg, Regensburg, Germany
| | - Jürgen R Schlaier
- 6Department of Neurosurgery, University Hospital Regensburg, Regensburg, Germany
| | - Manja Kloss
- 3Neurology, University Hospital Heidelberg, Heidelberg
| | | | - Karl L Kiening
- 1Department of Neurosurgery, Division of Stereotactic Neurosurgery, and
- Departments of2Neurosurgery and
| |
Collapse
|
35
|
Mackel CE, Papavassiliou E, Alterman RL. Risk Factors for Wire Fracture or Tethering in Deep Brain Stimulation: A 15-Year Experience. Oper Neurosurg (Hagerstown) 2020; 19:708-714. [DOI: 10.1093/ons/opaa215] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2019] [Accepted: 05/03/2020] [Indexed: 11/12/2022] Open
Abstract
Abstract
BACKGROUND
In deep brain stimulation (DBS), tunneled lead and extension wires connect the implantable pulse generator to the subcortical electrode, but circuit discontinuity and wire revision compromise a significant portion of treatments.
OBJECTIVE
To identify factors predisposing to fracture or tethering of the lead or extension wire in patients undergoing DBS.
METHOD
Retrospective review of wire-related complications was performed in a consecutive series of patients treated with DBS at a tertiary academic medical center over 15 yr.
RESULTS
A total of 275 patients had 513 extension wires implanted or revised. There were 258 extensions of 40 cm implanted with a postauricular connector (50.3%), 229 extensions of 60 cm with a parietal connector (44.6%), and 26 extensions 40 cm with a parietal connector (5.1%). In total, 26 lead or extension wires (5.1%) were replaced for fracture. Fracture rates for 60 cm extensions with a parietal connector, 40 cm wires with a postauricular connector, and 40 cm extensions with a parietal connector were 0.2, 1.4, and 12.9 fractures per 100 wire-years, significantly different on log-rank test. Total 16 (89%) 40 cm extension wires with a postauricular connector had fracture implicating the lead wire. Tethering occurred only in patients with 60 cm extensions with parietal connectors (1.14 tetherings per 100 wire-years). Reoperation rate correlated with younger age, dystonia, and target in the GPI.
CONCLUSION
The 40 cm extensions with parietal connectors have the highest fracture risk and should be avoided. Postauricular connectors risk lead wire fracture and should be employed cautiously. The 60 cm parietal wires may reduce fracture risk but increase tethering risk.
Collapse
Affiliation(s)
- Charles E Mackel
- Department of Neurosurgery, Beth Israel Deaconess Medical Center, Boston, Massachusetts
| | | | - Ron L Alterman
- Department of Neurosurgery, Beth Israel Deaconess Medical Center, Boston, Massachusetts
| |
Collapse
|
36
|
Raza SA, Opie NL, Morokoff A, Sharma RP, Mitchell PJ, Oxley TJ. Endovascular Neuromodulation: Safety Profile and Future Directions. Front Neurol 2020; 11:351. [PMID: 32390937 PMCID: PMC7193719 DOI: 10.3389/fneur.2020.00351] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2019] [Accepted: 04/08/2020] [Indexed: 12/16/2022] Open
Abstract
Endovascular neuromodulation is an emerging technology that represents a synthesis between interventional neurology and neural engineering. The prototypical endovascular neural interface is the StentrodeTM, a stent-electrode array which can be implanted into the superior sagittal sinus via percutaneous catheter venography, and transmits signals through a transvenous lead to a receiver located subcutaneously in the chest. Whilst the StentrodeTM has been conceptually validated in ovine models, questions remain about the long term viability and safety of this device in human recipients. Although technical precedence for venous sinus stenting already exists in the setting of idiopathic intracranial hypertension, long term implantation of a lead within the intracranial veins has never been previously achieved. Contrastingly, transvenous leads have been successfully employed for decades in the setting of implantable cardiac pacemakers and defibrillators. In the current absence of human data on the StentrodeTM, the literature on these structurally comparable devices provides valuable lessons that can be translated to the setting of endovascular neuromodulation. This review will explore this literature in order to understand the potential risks of the StentrodeTM and define avenues where further research and development are necessary in order to optimize this device for human application.
Collapse
Affiliation(s)
- Samad A Raza
- Department of Neurosurgery, Royal Melbourne Hospital, Melbourne, VIC, Australia
| | - Nicholas L Opie
- Department of Medicine, Vascular Bionics Laboratory, Melbourne Brain Centre, The University of Melbourne, Melbourne, VIC, Australia
| | - Andrew Morokoff
- Department of Neurosurgery, Royal Melbourne Hospital, Melbourne, VIC, Australia
| | - Rahul P Sharma
- Interventional Cardiology, Stanford Health Care, Palo Alto, CA, United States
| | - Peter J Mitchell
- Department of Radiology, The University of Melbourne & The Royal Melbourne Hospital, Melbourne, VIC, Australia
| | - Thomas J Oxley
- Department of Medicine, Vascular Bionics Laboratory, Melbourne Brain Centre, The University of Melbourne, Melbourne, VIC, Australia.,Departments of Medicine and Neurology, Melbourne Brain Centre at The Royal Melbourne Hospital, The University of Melbourne, Melbourne, VIC, Australia.,Department of Neurosurgery, Mount Sinai Hospital, New York, NY, United States
| |
Collapse
|
37
|
Villalobos J, McDermott HJ, McNeill P, Golod A, Rathi V, Bauquier SH, Fallon JB. Slim electrodes for improved targeting in deep brain stimulation. J Neural Eng 2020; 17:026008. [PMID: 32101807 DOI: 10.1088/1741-2552/ab7a51] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE The efficacy of deep brain stimulation can be limited by factors including poor selectivity of stimulation, targeting error, and complications related to implant reliability and stability. We aimed to improve surgical outcomes by evaluating electrode leads with smaller diameter electrode and microelectrodes incorporated which can be used for assisting targeting. APPROACH Electrode arrays were constructed with two different diameters of 0.65 mm and the standard 1.3 mm. Micro-electrodes were incorporated into the slim electrode arrays for recording spiking neural activity. Arrays were bilaterally implanted into the medial geniculate body (MGB) in nine anaesthetised cats for 24-40 h using stereotactic techniques. Recordings of auditory evoked field potentials and multi-unit activity were obtained at 1 mm intervals along the electrode insertion track. Insertion trauma was evaluated histologically. MAIN RESULTS Evoked auditory field potentials were recorded from ring and micro-electrodes in the vicinity of the medial geniculate body. Spiking activity was recorded from 81% of the microelectrodes approaching the MGB. Histological examination showed localized surgical trauma along the implant. The extent of haemorrhage surrounding the track was measured and found to be significantly reduced with the slim electrodes (541 ± 455 µm vs. 827 ± 647 µm; P < 0.001). Scoring of the trauma, focusing on tissue disruption, haemorrhage, oedema of glial parenchyma and pyknosis, revealed a significantly lower trauma score for the slim electrodes (P < 0.0001). SIGNIFICANCE The slim electrodes reduced the extent of acute trauma, while still providing adequate electrode impedance for both stimulating and recording, and providing the option to target stimulate smaller volumes of tissue. The incorporation of microelectrodes into the electrode array may allow for a simplified, single-step surgical approach where confirmatory micro-targeting is done with the same lead used for permanent implantation.
Collapse
Affiliation(s)
- Joel Villalobos
- Bionics Institute, East Melbourne, Australia. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | |
Collapse
|
38
|
Levi V, Messina G, Franzini A, Laurenzio NED, Franzini A, Tringali G, Rizzi M. Antibiotic Impregnated Catheter Coating Technique for Deep Brain Stimulation Hardware Infection: An Effective Method to Avoid Intracranial Lead Removal. Oper Neurosurg (Hagerstown) 2020; 18:246-253. [PMID: 31144720 DOI: 10.1093/ons/opz118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 02/11/2019] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Few studies have proposed alternative salvage methods of deep brain stimulation (DBS) intracranial lead once the infection has already occurred. OBJECTIVE To assess the effectiveness of antibiotic impregnated catheter coverage of DBS leads in case of hardware infection. METHODS Patients with a hardware infection and consequent partial removal of extension and internal pulse generator (IPG) were reviewed. To diagnose an infection, criteria provided by the Guideline for Prevention of Surgical Site Infection were used. We compared the intracranial lead salvage rate between the group that underwent antibiotic catheter lead protection (group A) and the group that did not (group B). RESULTS A total of 231 DBS surgeries and 339 IPG replacements were performed from January 2012 to January 2017. Twenty-three hardware-related infections (4%) were identified. Nineteen patients (82.6%) underwent partial hardware removal with an attempt to spare intracranial lead. Of these, 8 patients (42.1%) had antibiotic catheter lead coverage (group A) while 11 patients (57.9%) did not receive any antibiotic protection (group B). At 6-mo follow-up, 6 patients had the extension and IPG successfully re-implanted in group A, whereas only 1 patient was successfully re-implanted in group B (75 vs 9.1%; P < .001). CONCLUSION The antibiotic impregnated catheter coating technique seems to be effective in avoiding intracranial lead removal in case of IPG or DBS extension-lead junction infection. This method does not require any surgical learning curve, it is safe and relatively inexpensive. Randomized, prospective, larger studies are needed to validate our results.
Collapse
Affiliation(s)
- Vincenzo Levi
- Neurosurgery Department, Functional Neurosurgery Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Giuseppe Messina
- Neurosurgery Department, Functional Neurosurgery Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Andrea Franzini
- Neurosurgery Department, Functional Neurosurgery Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | | | - Angelo Franzini
- Neurosurgery Department, Functional Neurosurgery Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Giovanni Tringali
- Neurosurgery Department, Functional Neurosurgery Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Michele Rizzi
- Neurosurgery Department, Functional Neurosurgery Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy.,"Claudio Munari" Center for Epilepsy Surgery, Niguarda Hospital-Milano, Milan, Italy.,Department of Neuroscience, University of Parma, Parma, Italy
| |
Collapse
|
39
|
Preston C, Alvarez AM, Barragan A, Becker J, Kasoff WS, Witte RS. High resolution transcranial acoustoelectric imaging of current densities from a directional deep brain stimulator. J Neural Eng 2020; 17:016074. [PMID: 31978914 PMCID: PMC7446234 DOI: 10.1088/1741-2552/ab6fc3] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE New innovations in deep brain stimulation (DBS) enable directional current steering-allowing more precise electrical stimulation of the targeted brain structures for Parkinson's disease, essential tremor and other neurological disorders. While intra-operative navigation through MRI or CT approaches millimeter accuracy for placing the DBS leads, no existing modality provides feedback of the currents as they spread from the contacts through the brain tissue. In this study, we investigate transcranial acoustoelectric imaging (tAEI) as a new modality to non-invasively image and characterize current produced from a directional DBS lead. tAEI uses ultrasound (US) to modulate tissue resistivity to generate detectable voltage signals proportional to the local currents. APPROACH An 8-channel directional DBS lead (Infinity 6172ANS, Abbott Inc) was inserted inside three adult human skulls submerged in 0.9% NaCl. A 2.5 MHz linear array delivered US pulses through the transtemporal window and focused near the contacts on the lead, while a custom amplifier and acquisition system recorded the acoustoelectric (AE) interaction used to generate images. MAIN RESULTS tAEI detected monopolar current with stimulation pulses as short as 100 µs with an SNR ranging from 10-27 dB when using safe US pressure (mechanical indices <0.78) and injected current of ~2 mA peak amplitude. Adjacent contacts were discernable along the length and within each ring of the lead with a mean radial separation between contacts of 2.10 and 1.34 mm, respectively. SIGNIFICANCE These results demonstrate the feasibility of tAEI for high resolution mapping of directional DBS currents using clinically-relevant stimulation parameters. This new modality may improve the accuracy for placing the DBS leads, guide calibration and programming, and monitor long-term performance of DBS for treatment of Parkinson's disease.
Collapse
Affiliation(s)
- Chet Preston
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, United States of America
| | - Alexander M Alvarez
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, United States of America
| | - Andres Barragan
- Department of Computer Science, University of Arizona, Tucson, AZ, United States of America
| | - Jennifer Becker
- Department of Medical Imaging, University of Arizona, Tucson, AZ, United States of America
| | - Willard S Kasoff
- Department of Surgery, University of Arizona, Tucson, AZ, United States of America
| | - Russell S Witte
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, United States of America
- Department of Medical Imaging, University of Arizona, Tucson, AZ, United States of America
| |
Collapse
|
40
|
Postoperative Imaging of Complications Following Cranial Implants. J Belg Soc Radiol 2019; 103:81. [PMID: 31872175 PMCID: PMC6923773 DOI: 10.5334/jbsr.1881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
A wide range of neurosurgical implants, cranioplasty materials and catheters have been developed to treat a variety of intracranial disorders. Interpretation of postoperative imaging can be challenging and confounded by postoperative changes and implant-related complications. Review of recent literature suggested that there is a paucity of data on postoperative cranial implant-related complications. If not addressed appropriately in a timely manner, these complications may cause a delay in the patient’s treatment with subsequent prolongation of hospital stay. It is therefore paramount for clinicians and radiologists to be aware of the appearance of these implant-related complications on imaging during postoperative surveillance.
Collapse
|
41
|
Bullard AJ, Hutchison BC, Lee J, Chestek CA, Patil PG. Estimating Risk for Future Intracranial, Fully Implanted, Modular Neuroprosthetic Systems: A Systematic Review of Hardware Complications in Clinical Deep Brain Stimulation and Experimental Human Intracortical Arrays. Neuromodulation 2019; 23:411-426. [DOI: 10.1111/ner.13069] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Revised: 08/05/2019] [Accepted: 09/10/2019] [Indexed: 01/08/2023]
Affiliation(s)
- Autumn J. Bullard
- Department of Biomedical Engineering University of Michigan Ann Arbor MI USA
| | | | - Jiseon Lee
- Department of Biomedical Engineering University of Michigan Ann Arbor MI USA
| | - Cynthia A. Chestek
- Department of Biomedical Engineering University of Michigan Ann Arbor MI USA
- Department of Electrical Engineering and Computer Science University of Michigan Ann Arbor MI USA
| | - Parag G. Patil
- Department of Biomedical Engineering University of Michigan Ann Arbor MI USA
- Department of Neurosurgery University of Michigan Medical School Ann Arbor MI USA
| |
Collapse
|
42
|
Sobstyl M, Stapińska-Syniec A, Giziński J, Kmieć T, Kupryjaniuk A. Deep brain stimulation hardware-related complications and their management: A single-center retrospective analysis of 65 patients with various dystonic conditions. J Neurol Sci 2019; 407:116513. [PMID: 31678789 DOI: 10.1016/j.jns.2019.116513] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2019] [Revised: 08/26/2019] [Accepted: 09/28/2019] [Indexed: 10/25/2022]
Affiliation(s)
- Michał Sobstyl
- Department of Neurosurgery, Institute of Psychiatry and Neurology, Sobieskiego 9 Street, 02-957 Warsaw, Poland.
| | - Angelika Stapińska-Syniec
- Department of Neurosurgery, Institute of Psychiatry and Neurology, Sobieskiego 9 Street, 02-957 Warsaw, Poland
| | - Jakub Giziński
- Department of Neurosurgery, Institute of Psychiatry and Neurology, Sobieskiego 9 Street, 02-957 Warsaw, Poland
| | - Tomasz Kmieć
- Department of Neurology, Children's Memorial Health Institute, Aleja Dzieci Polskich 20, 04-730 Warsaw, Poland
| | - Anna Kupryjaniuk
- Department of Neurosurgery, Institute of Psychiatry and Neurology, Sobieskiego 9 Street, 02-957 Warsaw, Poland
| |
Collapse
|
43
|
Fernandez-Garcia C, Alonso-Frech F, Monje MHG, Matias-Guiu J. Role of deep brain stimulation therapy in the magnetic resonance-guided high-frequency focused ultrasound era: current situation and future prospects. Expert Rev Neurother 2019; 20:7-21. [PMID: 31623494 DOI: 10.1080/14737175.2020.1677465] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Introduction: Deep brain stimulation (DBS) is a well-established treatment of movement disorders; but recently there has been an increasing trend toward the ablative procedure magnetic resonance-guided focused ultrasound (MRgFU). DBS is an efficient neuromodulatory technique but associated with surgical complications. MRIgFUS is an incision-free method that allows thermal lesioning, with fewer surgical complications but irreversible effects.Areas covered: We look at current and prospective aspects of both techniques. In DBS, appropriate patient selection, improvement in surgical expertise, target accuracy (preoperative and intraoperative imaging), neurophysiological recordings, and novel segmented leads need to be considered. However, increased number of older patients with higher comorbidities and risk of DBS complications (mainly intracranial hemorrhage, but also infections, hardware complications) make them not eligible for surgery. With MRgFUS, hemorrhage risks are virtually nonexistent, infection or hardware malfunction are eliminated, while irreversible side effects can appear.Expert commentary: Comparison of the efficacy and risks associated with these techniques, in combination with a growing aged population in developed countries with higher comorbidities and a preference for less invasive treatments, necessitates a review of the indications for movement disorders and the most appropriate treatment modalities.
Collapse
Affiliation(s)
- C Fernandez-Garcia
- Department of Neurosurgery, Hospital Clínico San Carlos, San Carlos Research Health Institute (IdISSC), Madrid, Spain.,Medicine Department, Universidad Complutense, Madrid, Spain
| | - F Alonso-Frech
- Department of Neurology, Hospital Clínico San Carlos, San Carlos Research Health Institute (IdISSC), Universidad Complutense, Madrid, Spain.,HM CINAC, Hospital Universitario HM Puerta del Sur, Universidad CEU-San Pablo, Móstoles, Madrid, Spain
| | - M H G Monje
- HM CINAC, Hospital Universitario HM Puerta del Sur, Universidad CEU-San Pablo, Móstoles, Madrid, Spain
| | - J Matias-Guiu
- Medicine Department, Universidad Complutense, Madrid, Spain.,Department of Neurology, Hospital Clínico San Carlos, San Carlos Research Health Institute (IdISSC), Universidad Complutense, Madrid, Spain
| |
Collapse
|
44
|
Koy A, Bockhorn N, Kühn A, Schneider GH, Krause P, Lauritsch K, Witt K, Paschen S, Deuschl G, Krauss J, Saryyeva A, Runge J, Borggraefe I, Mehrkens J, Horn A, Vesper J, Schnitzler A, Siegert S, Freilinger M, Eckenweiler M, Coenen V, Tadic V, Voges J, Pauls K, Wirths J, Timmermann L, Hellmich M, Abdallat M, Ascencao LC, Grünwald S, Wloch A, Schrader C, Groiss SJ, Wojtecki L. Adverse events associated with deep brain stimulation in patients with childhood-onset dystonia. Brain Stimul 2019; 12:1111-1120. [DOI: 10.1016/j.brs.2019.04.003] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 03/15/2019] [Accepted: 04/02/2019] [Indexed: 11/29/2022] Open
|
45
|
Farrokhi FR, Marsans MT, Sikora M, Monsell SE, Wright AK, Palmer M, Hoefer A, McLeod P, Mark J, Carlson J. Pre-operative smoking history increases risk of infection in deep brain stimulation surgery. J Clin Neurosci 2019; 69:88-92. [PMID: 31445813 DOI: 10.1016/j.jocn.2019.08.026] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Accepted: 08/04/2019] [Indexed: 12/12/2022]
Abstract
Although general risk of deep brain stimulation (DBS) therapy has been previously described, application of risk prediction at the individual patient level is still largely at the discretion of a treating physician or a multidisciplinary team. To explore associations between potentially modifiable patient characteristics and common adverse events following DBS surgery, we retrospectively reviewed consecutive adult patients who had undergone new DBS electrode placement surgeries at two high-volume tertiary referral centers between October 1997 and May 2018. Among 501 patients included in the analysis (mean age (SD), 64.6 (10.4) years), 165 (32.9%) were female, 67 (13.4%) had diabetes, 231 (46.1%) had hypertension, 25 (5.0%) were smokers, 27 (5.4%) developed an infection, 15 (3.0%) had intracranial or intraventricular hemorrhage, and 53 (10.6%) had an unplanned return to the operating room. Patients who developed a surgical site infection were more likely to report history of smoking before DBS surgery (16% vs 5%, p = 0.04). There was a trend for patients with hypertension to be at risk for intracranial hemorrhage (p = 0.11). In conclusion, this multicenter study demonstrated an association between preoperative smoking and increased risk of infection following new DBS implantation surgery. Counseling about this risk should be considered in preoperative evaluation of patients who are considering undergoing a DBS procedure.
Collapse
Affiliation(s)
- Farrokh R Farrokhi
- Department of Neurosurgery, Virginia Mason Hospital, 1100 Ninth Ave, Seattle, WA 98101, USA; Neuroscience Institute, Virginia Mason Hospital, 1100 Ninth Ave, Seattle, WA 98101, USA.
| | - Maria T Marsans
- Department of Neurosurgery, Virginia Mason Hospital, 1100 Ninth Ave, Seattle, WA 98101, USA; Neuroscience Institute, Virginia Mason Hospital, 1100 Ninth Ave, Seattle, WA 98101, USA
| | - Matt Sikora
- Neuroscience Institute, Virginia Mason Hospital, 1100 Ninth Ave, Seattle, WA 98101, USA
| | - Sarah E Monsell
- Center for Biomedical Statistics, University of Washington, NE Pacific St, Seattle, WA 98195, USA
| | - Anna K Wright
- Neuroscience Institute, Virginia Mason Hospital, 1100 Ninth Ave, Seattle, WA 98101, USA
| | - Meghan Palmer
- Inland Neurosurgery and Spine Associates, 105 West 8th Ave, Suite 200, Spokane, WA 99204, USA
| | - Aiden Hoefer
- Inland Neurosurgery and Spine Associates, 105 West 8th Ave, Suite 200, Spokane, WA 99204, USA
| | - Pam McLeod
- Inland Neurosurgery and Spine Associates, 105 West 8th Ave, Suite 200, Spokane, WA 99204, USA
| | - Jamie Mark
- Selkirk Neurology, 610 S Sherman St. Suite 201, Spokane, WA 99202, USA
| | - Jonathan Carlson
- Inland Neurosurgery and Spine Associates, 105 West 8th Ave, Suite 200, Spokane, WA 99204, USA
| |
Collapse
|
46
|
Carlson JD, Palmer M, Hoefer A, Cox E, McLeod P, Mark J, Aldred J. Deep Brain Stimulation Generator Replacement in End-Stage Parkinson Disease. World Neurosurg 2019; 128:e683-e687. [DOI: 10.1016/j.wneu.2019.04.233] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 04/26/2019] [Accepted: 04/27/2019] [Indexed: 11/29/2022]
|
47
|
Hartmann CJ, Fliegen S, Groiss SJ, Wojtecki L, Schnitzler A. An update on best practice of deep brain stimulation in Parkinson's disease. Ther Adv Neurol Disord 2019; 12:1756286419838096. [PMID: 30944587 PMCID: PMC6440024 DOI: 10.1177/1756286419838096] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Accepted: 02/01/2019] [Indexed: 11/16/2022] Open
Abstract
During the last 30 years, deep brain stimulation (DBS) has evolved into the clinical standard of care as a highly effective treatment for advanced Parkinson’s disease. Careful patient selection, an individualized anatomical target localization and meticulous evaluation of stimulation parameters for chronic DBS are crucial requirements to achieve optimal results. Current hardware-related advances allow for a more focused, individualized stimulation and hence may help to achieve optimal clinical results. However, current advances also increase the degrees of freedom for DBS programming and therefore challenge the skills of healthcare providers. This review gives an overview of the clinical effects of DBS, the criteria for patient, target, and device selection, and finally, offers strategies for a structured programming approach.
Collapse
Affiliation(s)
- Christian J Hartmann
- Department of Neurology/Institute of Clinical Neuroscience and Medical Psychology, Medical Faculty, Heinrich-Heine University Düsseldorf, Moorenstraße 5, 40225 Düsseldorf, Germany
| | - Sabine Fliegen
- Department of Neurology/Institute of Clinical Neuroscience and Medical Psychology, Medical Faculty, Heinrich-Heine University Düsseldorf, Düsseldorf, Germany
| | - Stefan J Groiss
- Department of Neurology/Institute of Clinical Neuroscience and Medical Psychology, Medical Faculty, Heinrich-Heine University Düsseldorf, Düsseldorf, Germany
| | - Lars Wojtecki
- Department of Neurology/Institute of Clinical Neuroscience and Medical Psychology, Medical Faculty, Heinrich-Heine University Düsseldorf, Düsseldorf, Germany
| | - Alfons Schnitzler
- Department of Neurology/Institute of Clinical Neuroscience and Medical Psychology, Medical Faculty, Heinrich-Heine University Düsseldorf, Düsseldorf, Germany
| |
Collapse
|
48
|
Andrade P, Banuelos-Cabrera I, Lapinlampi N, Paananen T, Ciszek R, Ndode-Ekane XE, Pitkänen A. Acute Non-Convulsive Status Epilepticus after Experimental Traumatic Brain Injury in Rats. J Neurotrauma 2019; 36:1890-1907. [PMID: 30543155 DOI: 10.1089/neu.2018.6107] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Severe traumatic brain injury (TBI) induces seizures or status epilepticus (SE) in 20-30% of patients during the acute phase. We hypothesized that severe TBI induced with lateral fluid-percussion injury (FPI) triggers post-impact SE. Adult Sprague-Dawley male rats were anesthetized with isoflurane and randomized into the sham-operated experimental control or lateral FPI-induced severe TBI groups. Electrodes were implanted right after impact or sham-operation, then video-electroencephalogram (EEG) monitoring was started. In addition, video-EEG was recorded from naïve rats. During the first 72 h post-TBI, injured rats had seizures that were intermingled with other epileptiform EEG patterns typical to non-convulsive SE, including occipital intermittent rhythmic delta activity, lateralized or generalized periodic discharges, spike-and-wave complexes, poly-spikes, poly-spike-and-wave complexes, generalized continuous spiking, burst suppression, or suppression. Almost all (98%) of the electrographic seizures were recorded during 0-72 h post-TBI (23.2 ± 17.4 seizures/rat). Mean latency from the impact to the first electrographic seizure was 18.4 ± 15.1 h. Mean seizure duration was 86 ± 57 sec. Analysis of high-resolution videos indicated that only 41% of electrographic seizures associated with behavioral abnormalities, which were typically subtle (Racine scale 1-2). Fifty-nine percent of electrographic seizures did not show any behavioral manifestations. In most of the rats, epileptiform EEG patterns began to decay spontaneously on Days 5-6 after TBI. Interestingly, also a few sham-operated and naïve rats had post-operation seizures, which were not associated with EEG background patterns typical to non-convulsive SE seen in TBI rats. To summarize, our data show that lateral FPI-induced TBI results in non-convulsive SE with subtle behavioral manifestations; this explains why it has remained undiagnosed until now. The lateral FPI model provides a novel platform for assessing the mechanisms of acute symptomatic non-convulsive SE and for testing treatments to prevent post-injury SE in a clinically relevant context.
Collapse
Affiliation(s)
- Pedro Andrade
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Ivette Banuelos-Cabrera
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Niina Lapinlampi
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Tomi Paananen
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Robert Ciszek
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | | | - Asla Pitkänen
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
49
|
Abode-Iyamah KO, Chiang HY, Woodroffe RW, Park B, Jareczek FJ, Nagahama Y, Winslow N, Herwaldt L, Greenlee JD. Deep brain stimulation hardware-related infections: 10-year experience at a single institution. J Neurosurg 2019; 130:629-638. [PMID: 29521584 PMCID: PMC6858932 DOI: 10.3171/2017.9.jns1780] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2017] [Accepted: 09/25/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Deep brain stimulation is an effective surgical treatment for managing some neurological and psychiatric disorders. Infection related to the deep brain stimulator (DBS) hardware causes significant morbidity: hardware explantation may be required; initial disease symptoms such as tremor, rigidity, and bradykinesia may recur; and the medication requirements for adequate disease management may increase. These morbidities are of particular concern given that published DBS-related infection rates have been as high as 23%. To date, however, the key risk factors for and the potential preventive measures against these infections remain largely uncharacterized. In this study, the authors endeavored to identify possible risk factors for DBS-related infection and analyze the efficacy of prophylactic intrawound vancomycin powder (VP). METHODS The authors performed a retrospective cohort study of patients who had undergone primary DBS implantation at a single institution in the period from December 2005 through September 2015 to identify possible risk factors for surgical site infection (SSI) and to assess the impact of perioperative (before, during, and after surgery) prophylactic antibiotics on the SSI rate. They also evaluated the effect of a change in the National Healthcare Safety Network's definition of SSI on the number of infections detected. Statistical analyses were performed using the 2-sample t-test, the Wilcoxon rank-sum test, the chi-square test, Fisher's exact test, or logistic regression, as appropriate for the variables examined. RESULTS Four hundred sixty-four electrodes were placed in 242 adults during 245 primary procedures over approximately 10.5 years; most patients underwent bilateral electrode implantation. Among the 245 procedures, 9 SSIs (3.7%) occurred within 90 days and 16 (6.5%) occurred within 1 year of DBS placement. Gram-positive bacteria were the most common etiological agents. Most patient- and procedure-related characteristics did not differ between those who had acquired an SSI and those who had not. The rate of SSIs among patients who had received intrawound VP was only 3.3% compared with 9.7% among those who had not received topical VP (OR 0.32, 95% CI 0.10-1.02, p = 0.04). After controlling for patient sex, the association between VP and decreased SSI risk did not reach the predetermined level of significance (adjusted OR 0.32, 95% CI 0.10-1.03, p = 0.06). The SSI rates were similar after staged and unstaged implantations. CONCLUSIONS While most patient-related and procedure-related factors assessed in this study were not associated with the risk for an SSI, the data did suggest that intrawound VP may help to reduce the SSI risk after DBS implantation. Furthermore, given the implications of SSI after DBS surgery and the frequency of infections occurring more than 90 days after implantation, continued follow-up for at least 1 year after such a procedure is prudent to establish the true burden of these infections and to properly treat them when they do occur.
Collapse
Affiliation(s)
- Kingsley O. Abode-Iyamah
- Departments of Neurosurgery, The University of Iowa Carver College of Medicine, Iowa City, IA 52242, USA
| | - Hsiu-Yin Chiang
- Internal Medicine, The University of Iowa Carver College of Medicine, Iowa City, IA 52242, USA
| | - Royce W. Woodroffe
- Departments of Neurosurgery, The University of Iowa Carver College of Medicine, Iowa City, IA 52242, USA
| | - Brian Park
- The University of Iowa Carver College of Medicine, Iowa City, IA 52242, USA
| | | | - Yasunori Nagahama
- Departments of Neurosurgery, The University of Iowa Carver College of Medicine, Iowa City, IA 52242, USA
| | - Nolan Winslow
- The University of Iowa Carver College of Medicine, Iowa City, IA 52242, USA
| | - Loreen Herwaldt
- Internal Medicine, The University of Iowa Carver College of Medicine, Iowa City, IA 52242, USA
- Program of Hospital Epidemiology, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA
- Department of Epidemiology, The University of Iowa College of Public Health, Iowa City, IA 55242, USA
| | - Jeremy D.W. Greenlee
- Departments of Neurosurgery, The University of Iowa Carver College of Medicine, Iowa City, IA 52242, USA
| |
Collapse
|
50
|
Whiting AC, Catapano JS, Walker CT, Godzik J, Lambert M, Ponce FA. Peri-Lead Edema After Deep Brain Stimulation Surgery: A Poorly Understood but Frequent Complication. World Neurosurg 2018; 124:S1878-8750(18)32915-2. [PMID: 30594699 DOI: 10.1016/j.wneu.2018.12.092] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Accepted: 12/13/2018] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Postoperative peri-lead edema (PLE) is a poorly understood complication of deep brain stimulation (DBS), which has been described sporadically in patients presenting with profound and often delayed symptoms. We performed a prospective evaluation of patients undergoing DBS to determine the frequency of and identify risk factors for PLE. METHODS Patients underwent DBS electrode placement by a single physician. Postoperative magnetic resonance imaging (MRI) was performed approximately 6 weeks after the operation in asymptomatic subjects and analyzed for presence of PLE. All symptomatic subjects underwent MRI at the time of presentation. Data regarding index disease, preoperative medical issues, operative technique, and intraoperative variables were collected and statistically analyzed. RESULTS A total of 191 leads were placed in 102 subjects; 15 patients (14.7%) demonstrated PLE. Seven patients (6.9%) presented with symptoms related to PLE, most often altered mental status or neurologic deficit. Many of the MRI findings were profound, with PLE sometimes several centimeters in diameter. No statistically significant difference was found between PLE-positive and normal subjects when analyzing multiple variables, including presence of vascular disease, hypertension, anticoagulant/antiplatelet use, electrode target, index disease, unilateral versus bilateral lead placement, number of brain penetrations, and presence or absence of microelectrode recording. CONCLUSIONS Patients with postoperative PLE can present with severe symptoms or can be asymptomatic and go undiagnosed. Because of the delayed-onset potential, PLE may be more common than previously reported. No clear risk factors have been identified; therefore, further studies and increased clinical vigilance are paramount for improving comprehension and possible prevention of PLE.
Collapse
Affiliation(s)
- Alexander C Whiting
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA
| | - Joshua S Catapano
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA
| | - Corey T Walker
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA
| | - Jakub Godzik
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA
| | - Margaret Lambert
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA
| | - Francisco A Ponce
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA.
| |
Collapse
|