1
|
Cao J, Yuan C, Zhang Y, Quan Y, Chang P, Yang J, Song Q, Miao Y. Observation of intracranial artery and venous sinus hemodynamics using compressed sensing-accelerated 4D flow MRI: performance at different acceleration factors. Front Neurosci 2024; 18:1438003. [PMID: 39119457 PMCID: PMC11306029 DOI: 10.3389/fnins.2024.1438003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Accepted: 07/11/2024] [Indexed: 08/10/2024] Open
Abstract
Objective To investigate the feasibility and performance of 4D flow MRI accelerated by compressed sensing (CS) for the hemodynamic quantification of intracranial artery and venous sinus. Materials and methods Forty healthy volunteers were prospectively recruited, and 20 volunteers underwent 4D flow MRI of cerebral artery, and the remaining volunteers underwent 4D flow MRI of venous sinus. A series of 4D flow MRI was acquired with different acceleration factors (AFs), including sensitivity encoding (SENSE, AF = 4) and CS (AF = CS4, CS6, CS8, and CS10) at a 3.0 T MRI scanner. The hemodynamic parameters, including flow rate, mean velocity, peak velocity, max axial wall shear stress (WSS), average axial WSS, max circumferential WSS, average circumferential WSS, and 3D WSS, were calculated at the internal carotid artery (ICA), transverse sinus (TS), straight sinus (SS), and superior sagittal sinus (SSS). Results Compared to the SENSE4 scan, for the left ICA C2, mean velocity measured by CS8 and CS10 groups, and 3D WSS measured by CS6, CS8, and CS10 groups were underestimated; for the right ICA C2, mean velocity measured by CS10 group, and 3D WSS measured by CS8 and CS10 groups were underestimated; for the right ICA C4, mean velocity measured by CS10 group, and 3D WSS measured by CS8 and CS10 groups were underestimated; and for the right ICA C7, mean velocity and 3D WSS measured by CS8 and CS10 groups, and average axial WSS measured by CS8 group were also underestimated (all p < 0.05). For the left TS, max axial WSS and 3D WSS measured by CS10 group were significantly underestimated (p = 0.032 and 0.003). Similarly, for SS, mean velocity, peak velocity, average axial WSS measured by the CS8 and CS10 groups, max axial WSS measured by CS6, CS8, and CS10 groups, and 3D WSS measured by CS10 group were significantly underestimated compared to the SENSE4 scan (p = 0.000-0.021). The hemodynamic parameters measured by CS4 group had only minimal bias and great limits of agreement compared to conventional 4D flow (SENSE4) in the ICA and every venous sinus (the max/min upper limit to low limit of the 95% limits of agreement = 11.4/0.03 to 0.004/-5.7, 14.4/0.05 to -0.03/-9.0, 12.6/0.04 to -0.03/-9.4, 16.8/0.04 to 0.6/-14.1; the max/min bias = 5.0/-1.2, 3.5/-1.4, 4.5/-1.1, 6.6/-4.0 for CS4, CS6, CS8, and CS10, respectively). Conclusion CS4 strikes a good balance in 4D flow between flow quantifications and scan time, which could be recommended for routine clinical use.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Yanwei Miao
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| |
Collapse
|
2
|
Liu J, Jakary A, Villanueva-Meyer JE, Butowski NA, Saloner D, Clarke JL, Taylor JW, Oberheim Bush NA, Chang SM, Xu D, Lupo JM. Automatic Brain Tissue and Lesion Segmentation and Multi-Parametric Mapping of Contrast-Enhancing Gliomas without the Injection of Contrast Agents: A Preliminary Study. Cancers (Basel) 2024; 16:1524. [PMID: 38672606 PMCID: PMC11049314 DOI: 10.3390/cancers16081524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2024] [Revised: 04/08/2024] [Accepted: 04/15/2024] [Indexed: 04/28/2024] Open
Abstract
This study aimed to develop a rapid, 1 mm3 isotropic resolution, whole-brain MRI technique for automatic lesion segmentation and multi-parametric mapping without using contrast by continuously applying balanced steady-state free precession with inversion pulses throughout incomplete inversion recovery in a single 6 min scan. Modified k-means clustering was performed for automatic brain tissue and lesion segmentation using distinct signal evolutions that contained mixed T1/T2/magnetization transfer properties. Multi-compartment modeling was used to derive quantitative multi-parametric maps for tissue characterization. Fourteen patients with contrast-enhancing gliomas were scanned with this sequence prior to the injection of a contrast agent, and their segmented lesions were compared to conventionally defined manual segmentations of T2-hyperintense and contrast-enhancing lesions. Simultaneous T1, T2, and macromolecular proton fraction maps were generated and compared to conventional 2D T1 and T2 mapping and myelination water fraction mapping acquired with MAGiC. The lesion volumes defined with the new method were comparable to the manual segmentations (r = 0.70, p < 0.01; t-test p > 0.05). The T1, T2, and macromolecular proton fraction mapping values of the whole brain were comparable to the reference values and could distinguish different brain tissues and lesion types (p < 0.05), including infiltrating tumor regions within the T2-lesion. Highly efficient, whole-brain, multi-contrast imaging facilitated automatic lesion segmentation and quantitative multi-parametric mapping without contrast, highlighting its potential value in the clinic when gadolinium is contraindicated.
Collapse
Affiliation(s)
- Jing Liu
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94143, USA; (A.J.); (D.X.)
| | - Angela Jakary
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94143, USA; (A.J.); (D.X.)
| | - Javier E. Villanueva-Meyer
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94143, USA; (A.J.); (D.X.)
- Department of Neurological Surgery, University of California San Francisco, San Francisco, CA 94143, USA; (N.A.B.); (J.L.C.); (S.M.C.)
| | - Nicholas A. Butowski
- Department of Neurological Surgery, University of California San Francisco, San Francisco, CA 94143, USA; (N.A.B.); (J.L.C.); (S.M.C.)
| | - David Saloner
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94143, USA; (A.J.); (D.X.)
- Radiology Service, VA Medical Center, San Francisco, CA 94121, USA
| | - Jennifer L. Clarke
- Department of Neurological Surgery, University of California San Francisco, San Francisco, CA 94143, USA; (N.A.B.); (J.L.C.); (S.M.C.)
- Department of Neurology, University of California San Francisco, San Francisco, CA 94143, USA
| | - Jennie W. Taylor
- Department of Neurological Surgery, University of California San Francisco, San Francisco, CA 94143, USA; (N.A.B.); (J.L.C.); (S.M.C.)
- Department of Neurology, University of California San Francisco, San Francisco, CA 94143, USA
| | - Nancy Ann Oberheim Bush
- Department of Neurological Surgery, University of California San Francisco, San Francisco, CA 94143, USA; (N.A.B.); (J.L.C.); (S.M.C.)
- Department of Neurology, University of California San Francisco, San Francisco, CA 94143, USA
| | - Susan M. Chang
- Department of Neurological Surgery, University of California San Francisco, San Francisco, CA 94143, USA; (N.A.B.); (J.L.C.); (S.M.C.)
| | - Duan Xu
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94143, USA; (A.J.); (D.X.)
- UCSF/UC Berkeley Graduate Program in Bioengineering, University of California San Francisco and Berkeley, San Francisco, CA 94143, USA
| | - Janine M. Lupo
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94143, USA; (A.J.); (D.X.)
- UCSF/UC Berkeley Graduate Program in Bioengineering, University of California San Francisco and Berkeley, San Francisco, CA 94143, USA
| |
Collapse
|
3
|
Venn J, Larkee CE, Garcia GJM, Rayz VL, LaDisa JF. A workflow for viewing biomedical computational fluid dynamics results and corresponding data within virtual and augmented reality environments. FRONTIERS IN MEDICAL TECHNOLOGY 2023; 5:1096289. [PMID: 36908292 PMCID: PMC9996009 DOI: 10.3389/fmedt.2023.1096289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 01/26/2023] [Indexed: 02/25/2023] Open
Abstract
Researchers conducting computational fluid dynamics (CFD) modeling can spend weeks obtaining imaging data, determining boundary conditions, running simulations and post-processing files. However, results are typically viewed on a 2D display and often at one point in time thus reducing the dynamic and inherently three-dimensional data to a static image. Results from different pathologic states or cases are rarely compared in real-time, and supplementary data are seldom included. Therefore, only a fraction of CFD results are typically studied in detail, and associations between mechanical stimuli and biological response may be overlooked. Virtual and augmented reality facilitate stereoscopic viewing that may foster extraction of more information from CFD results by taking advantage of improved depth cues, as well as custom content development and interactivity, all within an immersive approach. Our objective was to develop a straightforward, semi-automated workflow for enhanced viewing of CFD results and associated data in an immersive virtual environment (IVE). The workflow supports common CFD software and has been successfully completed by novice users in about an hour, demonstrating its ease of use. Moreover, its utility is demonstrated across clinical research areas and IVE platforms spanning a range of cost and development considerations. We are optimistic that this advancement, which decreases and simplifies the steps to facilitate more widespread use of immersive CFD viewing, will foster more efficient collaboration between engineers and clinicians. Initial clinical feedback is presented, and instructional videos, manuals, templates and sample data are provided online to facilitate adoption by the community.
Collapse
Affiliation(s)
- John Venn
- Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, United States
| | | | - Guilherme J. M. Garcia
- Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, United States
| | - Vitaliy L. Rayz
- Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, United States
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, United States
| | - John F. LaDisa
- Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, United States
- Department of Pediatrics - Division of Cardiology, Herma Heart Institute, Children’s Wisconsin and the Medical College of Wisconsin, Milwaukee, WI, United States
| |
Collapse
|
4
|
Aristova M, Pang J, Ma Y, Ma L, Berhane H, Rayz V, Markl M, Schnell S. Accelerated dual-venc 4D flow MRI with variable high-venc spatial resolution for neurovascular applications. Magn Reson Med 2022; 88:1643-1658. [PMID: 35754143 PMCID: PMC9392495 DOI: 10.1002/mrm.29306] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 04/02/2022] [Accepted: 04/26/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE Dual-velocity encoded (dual-venc or DV) 4D flow MRI achieves wide velocity dynamic range and velocity-to-noise ratio (VNR), enabling accurate neurovascular flow characterization. To reduce scan time, we present interleaved dual-venc 4D Flow with independently prescribed, prospectively undersampled spatial resolution of the high-venc (HV) acquisition: Variable Spatial Resolution Dual Venc (VSRDV). METHODS A prototype VSRDV sequence was developed based on a Cartesian acquisition with eight-point phase encoding, combining PEAK-GRAPPA acceleration with zero-filling in phase and partition directions for HV. The VSRDV approach was optimized by varying z, the zero-filling fraction of HV relative to low-venc, between 0%-80% in vitro (realistic neurovascular model with pulsatile flow) and in vivo (n = 10 volunteers). Antialiasing precision, mean and peak velocity quantification accuracy, and test-retest reproducibility were assessed relative to reference images with equal-resolution HV and low venc (z = 0%). RESULTS In vitro results for all z demonstrated an antialiasing true positive rate at least 95% for R PEAK - GRAPPA $$ {R}_{\mathrm{PEAK}-\mathrm{GRAPPA}} $$ = 2 and 5, with no linear relationship to z (p = 0.62 and 0.13, respectively). Bland-Altman analysis for z = 20%, 40%, 60%, or 80% versus z = 0% in vitro and in vivo demonstrated no bias >1% of venc in mean or peak velocity values at any R ZF $$ {R}_{\mathrm{ZF}} $$ . In vitro mean and peak velocity, and in vivo peak velocity, had limits of agreement within 15%. CONCLUSION VSRDV allows up to 34.8% scan time reduction compared to PEAK-GRAPPA accelerated DV 4D Flow MRI, enabling large spatial coverage and dynamic range while maintaining VNR and velocity measurement accuracy.
Collapse
Affiliation(s)
- Maria Aristova
- Department of RadiologyNorthwestern University Feinberg School of MedicineChicagoIllinoisUSA
| | - Jianing Pang
- Department of RadiologyNorthwestern University Feinberg School of MedicineChicagoIllinoisUSA
- MR R&D and CollaborationsSiemens Medical Solutions USA Inc.ChicagoILUSA
| | - Yue Ma
- Department of RadiologyNorthwestern University Feinberg School of MedicineChicagoIllinoisUSA
- Department of RadiologyShengjing Hospital of China Medical UniversityShenyangChina
| | - Liliana Ma
- Department of RadiologyNorthwestern University Feinberg School of MedicineChicagoIllinoisUSA
| | - Haben Berhane
- Department of RadiologyNorthwestern University Feinberg School of MedicineChicagoIllinoisUSA
- Department of Biomedical EngineeringNorthwestern University McCormick School of EngineeringEvanstonIllinoisUSA
| | - Vitaliy Rayz
- Weldon School of Biomedical EngineeringPurdue University College of EngineeringWest LafayetteIndianaUSA
| | - Michael Markl
- Department of RadiologyNorthwestern University Feinberg School of MedicineChicagoIllinoisUSA
- Department of Biomedical EngineeringNorthwestern University McCormick School of EngineeringEvanstonIllinoisUSA
| | - Susanne Schnell
- Department of RadiologyNorthwestern University Feinberg School of MedicineChicagoIllinoisUSA
- Institut für PhysikUniversität GreifswaldGreifswaldGermany
| |
Collapse
|
5
|
Isoda H, Fukuyama A. Quality Control for 4D Flow MR Imaging. Magn Reson Med Sci 2022; 21:278-292. [PMID: 35197395 PMCID: PMC9680545 DOI: 10.2463/mrms.rev.2021-0165] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 01/08/2022] [Indexed: 01/06/2023] Open
Abstract
In recent years, 4D flow MRI has become increasingly important in clinical applications for the blood vessels in the whole body, heart, and cerebrospinal fluid. 4D flow MRI has advantages over 2D cine phase-contrast (PC) MRI in that any targeted area of interest can be analyzed post-hoc, but there are some factors to be considered, such as ensuring measurement accuracy, a long imaging time and post-processing complexity, and interobserver variability.Due to the partial volume phenomenon caused by low spatial and temporal resolutions, the accuracy of flow measurement in 4D flow MRI is reduced. For spatial resolution, it is recommended to include at least four voxels in the vessel of interest, and if possible, six voxels. In large vessels such as the aorta, large voxels can be secured and SNR can be maintained, but in small cerebral vessels, SNR is reduced, resulting in reduced accuracy. A temporal resolution of less than 40 ms is recommended. The velocity-to-noise ratio (VNR) of low-velocity blood flow is low, resulting in poor measurement accuracy. The use of dual velocity encoding (VENC) or multi-VENC is recommended to avoid velocity wrap around and to increase VNR. In order to maintain sufficient spatio-temporal resolution, a longer imaging time is required, leading to potential patient movement during examination and a corresponding decrease in measurement accuracy.For the clinical application of new technologies, including various acceleration techniques, in vitro and in vivo accuracy verification based on existing accuracy-validated 2D cine PC MRI and 4D flow MRI, as well as accuracy verification on the conservation of mass' principle, should be performed, and intraobserver repeatability, interobserver reproducibility, and test-retest reproducibility should be checked.
Collapse
Affiliation(s)
- Haruo Isoda
- Brain and Mind Research Center, Nagoya University, Nagoya, Aichi, Japan
- Biomedical Imaging Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Atsushi Fukuyama
- Faculty of Health Sciences, Department of Radiological Sciences, Japan Healthcare University, Sapporo, Hokkaido, Japan
| |
Collapse
|
6
|
Pravdivtseva MS, Gaidzik F, Berg P, Ulloa P, Larsen N, Jansen O, Hövener JB, Salehi Ravesh M. Influence of Spatial Resolution and Compressed SENSE Acceleration Factor on Flow Quantification with 4D Flow MRI at 3 Tesla. Tomography 2022; 8:457-478. [PMID: 35202203 PMCID: PMC8880336 DOI: 10.3390/tomography8010038] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 01/30/2022] [Accepted: 01/31/2022] [Indexed: 11/25/2022] Open
Abstract
Four-dimensional (4D) flow MRI allows quantifying flow in blood vessels–non invasively and in vivo. The clinical use of 4D flow MRI in small vessels, however, is hampered by long examination times and limited spatial resolution. Compressed SENSE (CS-SENSE) is a technique that can accelerate 4D flow dramatically. Here, we investigated the effect of spatial resolution and CS acceleration on flow measurements by using 4D flow MRI in small vessels in vitro at 3 T. We compared the flow in silicon tubes (inner diameters of 2, 3, 4, and 5 mm) measured with 4D flow MRI, accelerated with four CS factors (CS = 2.5, 4.5, 6.5, and 13) and three voxel sizes (0.5, 1, and 1.5 mm3) to 2D flow MRI and a flow sensor. Additionally, the velocity field in an aneurysm model acquired with 4D flow MRI was compared to the one simulated with computational fluid dynamics (CFD). A strong correlation was observed between flow sensor, 2D flow MRI, and 4D flow MRI (rho > 0.94). The use of fewer than seven voxels per vessel diameter (nROI) resulted in an overestimation of flow in more than 5% of flow measured with 2D flow MRI. A negative correlation (rho = −0.81) between flow error and nROI were found for CS = 2.5 and 4.5. No statistically significant impact of CS factor on differences in flow rates was observed. However, a trend of increased flow error with increased CS factor was observed. In an aneurysm model, the peak velocity and stagnation zone were detected by CFD and all 4D flow MRI variants. The velocity difference error in the aneurysm sac did not exceed 11% for CS = 4.5 in comparison to CS = 2.5 for all spatial resolutions. Therefore, CS factors from 2.5–4.5 can appear suitable to improve spatial or temporal resolution for accurate quantification of flow rate and velocity. We encourage reporting the number of voxels per vessel diameter to standardize 4D flow MRI protocols.
Collapse
Affiliation(s)
- Mariya S. Pravdivtseva
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany; (P.U.); (J.-B.H.); (M.S.R.)
- Correspondence: ; Tel.: +49-(0)-431-500-16-533
| | - Franziska Gaidzik
- Department of Fluid Dynamics and Technical Flows, Research Campus STIMULATE, Magdeburg University, 39106 Magdeburg, Germany; (F.G.); (P.B.)
| | - Philipp Berg
- Department of Fluid Dynamics and Technical Flows, Research Campus STIMULATE, Magdeburg University, 39106 Magdeburg, Germany; (F.G.); (P.B.)
| | - Patricia Ulloa
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany; (P.U.); (J.-B.H.); (M.S.R.)
| | - Naomi Larsen
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel University, 24105 Kiel, Germany; (N.L.); (O.J.)
| | - Olav Jansen
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel University, 24105 Kiel, Germany; (N.L.); (O.J.)
| | - Jan-Bernd Hövener
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany; (P.U.); (J.-B.H.); (M.S.R.)
| | - Mona Salehi Ravesh
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany; (P.U.); (J.-B.H.); (M.S.R.)
| |
Collapse
|
7
|
Roberts GS, Loecher MW, Spahic A, Johnson KM, Turski PA, Eisenmenger LB, Wieben O. Virtual injections using 4D flow MRI with displacement corrections and constrained probabilistic streamlines. Magn Reson Med 2021; 87:2495-2511. [PMID: 34971458 PMCID: PMC8884720 DOI: 10.1002/mrm.29134] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 12/08/2021] [Accepted: 12/09/2021] [Indexed: 11/10/2022]
Abstract
PURPOSE Streamlines from 4D-flow MRI have been used clinically for intracranial blood-flow tracking. However, deterministic and stochastic errors degrade streamline quality. The purpose of this study is to integrate displacement corrections, probabilistic streamlines, and novel fluid constraints to improve selective blood-flow tracking and emulate "virtual bolus injections." METHODS Both displacement artifacts (deterministic) and velocity noise (stochastic) inherently occur during phase-contrast MRI acquisitions. Here, two displacement correction methods, single-step and iterative, were tested in silico with simulated displacements and were compared with ground-truth velocity fields. Next, the effects of combining displacement corrections and constrained probabilistic streamlines were performed in 10 healthy volunteers using time-averaged 4D-flow data. Measures of streamline length and depth into vasculature were then compared with streamlines generated with no corrections and displacement correction alone using one-way repeated-measures analysis of variance and Friedman's tests. Finally, virtual injections with improved streamlines were generated for three intracranial pathology cases. RESULTS Iterative displacement correction outperformed the single-step method in silico. In volunteers, the combination of displacement corrections and constrained probabilistic streamlines allowed for significant improvements in streamline length and increased the number of streamlines entering the circle of Willis relative to streamlines with no corrections and displacement correction alone. In the pathology cases, virtual injections with improved streamlines were qualitatively similar to dynamic arterial spin labeling images and allowed for forward/reverse selective flow tracking to characterize cerebrovascular malformations. CONCLUSION Virtual injections with improved streamlines from 4D-flow MRI allow for flexible, robust, intracranial flow tracking.
Collapse
Affiliation(s)
- Grant S Roberts
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Michael W Loecher
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Alma Spahic
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Kevin M Johnson
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Patrick A Turski
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Laura B Eisenmenger
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Oliver Wieben
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
8
|
Marlevi D, Schollenberger J, Aristova M, Ferdian E, Ma Y, Young AA, Edelman ER, Schnell S, Figueroa CA, Nordsletten DA. Noninvasive quantification of cerebrovascular pressure changes using 4D Flow MRI. Magn Reson Med 2021; 86:3096-3110. [PMID: 34431550 PMCID: PMC11421438 DOI: 10.1002/mrm.28928] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 05/24/2021] [Accepted: 06/25/2021] [Indexed: 12/28/2022]
Abstract
PURPOSE Hemodynamic alterations are indicative of cerebrovascular disease. However, the narrow and tortuous cerebrovasculature complicates image-based assessment, especially when quantifying relative pressure. Here, we present a systematic evaluation of image-based cerebrovascular relative pressure mapping, investigating the accuracy of the routinely used reduced Bernoulli (RB), the extended unsteady Bernoulli (UB), and the full-field virtual work-energy relative pressure ( ν WERP) method. METHODS Patient-specific in silico models were used to generate synthetic cerebrovascular 4D Flow MRI, with RB, UB, and ν WERP performance quantified as a function of spatiotemporal sampling and image noise. Cerebrovascular relative pressures were also derived in 4D Flow MRI from healthy volunteers ( n = 8 ), acquired at two spatial resolutions (dx = 1.1 and 0.8 mm). RESULTS The in silico analysis indicate that accurate relative pressure estimations are inherently coupled to spatial sampling: at dx = 1.0 mm high errors are reported for all methods; at dx = 0.5 mm ν WERP recovers relative pressures at a mean error of 0.02 ± 0.25 mm Hg, while errors remain higher for RB and UB (mean error of -2.18 ± 1.91 and -2.18 ± 1.87 mm Hg, respectively). The dependence on spatial sampling is also indicated in vivo, albeit with higher correlative dependence between resolutions using ν WERP (k = 0.64, R2 = 0.81 for dx = 1.1 vs. 0.8 mm) than with RB or UB (k = 0.04, R2 = 0.03, and k = 0.07, R2 = 0.07, respectively). CONCLUSION Image-based full-field methods such as ν WERP enable cerebrovascular relative pressure mapping; however, accuracy is directly dependent on utilized spatial resolution.
Collapse
Affiliation(s)
- David Marlevi
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Jonas Schollenberger
- Department of Surgery and Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Maria Aristova
- Department of Radiology, Northwestern University, Chicago, IL, USA
| | - Edward Ferdian
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
| | - Yue Ma
- Department of Radiology, Northwestern University, Chicago, IL, USA
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Alistair A. Young
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
- School of Biomedical Engineering and Imaging Sciences, The Rayne Institute, King’s College London, London, UK
| | - Elazer R. Edelman
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Susanne Schnell
- Department of Radiology, Northwestern University, Chicago, IL, USA
- Department of Medical Physics, Institute of Physics, University of Greifswald, Greifswald, Germany
| | - C. Alberto Figueroa
- Department of Surgery and Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - David A. Nordsletten
- Department of Surgery and Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
- School of Biomedical Engineering and Imaging Sciences, The Rayne Institute, King’s College London, London, UK
| |
Collapse
|
9
|
Zhang M, Peng F, Li Y, He L, Liu A, Li R. Associations between morphology and hemodynamics of intracranial aneurysms based on 4D flow and black-blood magnetic resonance imaging. Quant Imaging Med Surg 2021; 11:597-607. [PMID: 33532260 DOI: 10.21037/qims-20-440] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Background Previous studies have hypothesized that intracranial aneurysm (IA) morphology interacts with hemodynamic conditions. Magnetic resonance imaging (MRI) provides a single image modality solution for both morphological and hemodynamic measurements for IA. This study aimed to explore the interaction between the morphology and hemodynamics of IA using black-blood MRI (BB-MRI) and 4D flow MRI. Methods A total of 97 patients with unruptured IA were recruited for this study. The IA size, size ratio (SR), and minimum wall thickness (mWT) were measured using BB-MRI. Velocity, blood flow, pulsatility index (PI), and wall shear stress (WSS) were measured with 4D flow MRI. The relationship between hemodynamic parameters and morphological indices was investigated by linear regression analysis and unpaired two-sample t-test. To determine the independent interaction, multiple linear regression analysis was further performed. Results The findings showed that mWT was negatively correlated with IA size (r=-0.665, P<0.001). Maximum blood flow in IA (FlowIA) was positively correlated with IA size (r=0.458, P<0.001). The average WSS (WSSavg) was negatively correlated with IA size (r=-0.650, P<0.001). The relationships remained the same after the multivariate analysis was adjusted for hemodynamic, morphologic, and demographic confounding factors. The WSSavg was positively correlated with mWT (r=0.528, P<0.001). In the unpaired two-sample t-test, mWT, WSSavg, and FlowIA were statistically significantly associated with the size and SR of IAs. Conclusions There is potential for BB-MRI and 4D flow MRI to provide morphological and hemodynamic information regarding IA. Blood flow, WSS, and mWT may serve as non-invasive biomarkers for IA assessments, and may contribute to a more comprehensive understanding of the mechanism of IA.
Collapse
Affiliation(s)
- Miaoqi Zhang
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Fei Peng
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China.,Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Capital Medical University, China.,China National Clinical Research Center for Neurological Diseases, Beijing, China
| | - Yunduo Li
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Le He
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Aihua Liu
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China.,Department of Interventional Neuroradiology, Beijing Tiantan Hospital, Capital Medical University, China.,China National Clinical Research Center for Neurological Diseases, Beijing, China
| | - Rui Li
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| |
Collapse
|
10
|
Settecase F, Rayz VL. Advanced vascular imaging techniques. HANDBOOK OF CLINICAL NEUROLOGY 2021; 176:81-105. [DOI: 10.1016/b978-0-444-64034-5.00016-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
11
|
Peyvandi S, Xu D, Wang Y, Hogan W, Moon-Grady A, Barkovich AJ, Glenn O, McQuillen P, Liu J. Fetal Cerebral Oxygenation Is Impaired in Congenital Heart Disease and Shows Variable Response to Maternal Hyperoxia. J Am Heart Assoc 2020; 10:e018777. [PMID: 33345557 PMCID: PMC7955474 DOI: 10.1161/jaha.120.018777] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Background Impairments in fetal oxygen delivery have been implicated in brain dysmaturation seen in congenital heart disease (CHD), suggesting a role for in utero transplacental oxygen therapy. We applied a novel imaging tool to quantify fetal cerebral oxygenation by measuring T2* decay. We compared T2* in fetuses with CHD with controls with a focus on cardiovascular physiologies (transposition or left‐sided obstruction) and described the effect of brief administration of maternal hyperoxia on T2* decay. Methods and Results This is a prospective study performed on pregnant mothers with a prenatal diagnosis of CHD compared with controls in the third trimester. Participants underwent a fetal brain magnetic resonance imaging scan including a T2* sequence before and after maternal hyperoxia. Comparisons were made between control and CHD fetuses including subgroup analyses by cardiac physiology. Forty‐four mothers (CHD=24, control=20) participated. Fetuses with CHD had lower total brain volume (238.2 mm3, 95% CI, 224.6–251.9) compared with controls (262.4 mm3, 95% CI, 245.0–279.8, P=0.04). T2* decay time was faster in CHD compared with controls (beta=−14.4, 95% CI, −23.3 to −5.6, P=0.002). The magnitude of change in T2* with maternal hyperoxia was higher in fetuses with transposition compared with controls (increase of 8.4 ms, 95% CI, 0.5–14.3, P=0.01), though between‐subject variability was noted. Conclusions Cerebral tissue oxygenation is lower in fetuses with complex CHD. There was variability in the response to maternal hyperoxia by CHD subgroup that can be tested in future larger studies. Cardiovascular physiology is critical when designing neuroprotective clinical trials in the fetus with CHD.
Collapse
Affiliation(s)
- Shabnam Peyvandi
- Department of Pediatrics Division of Cardiology University of California San Francisco San Francisco CA.,Department of Epidemiology and Biostatistics University of California San Francisco San Francisco CA
| | - Duan Xu
- Department of Radiology and Biomedical Imaging University of California San Francisco San Francisco CA
| | - Yan Wang
- Department of Radiology and Biomedical Imaging University of California San Francisco San Francisco CA
| | - Whitnee Hogan
- Department of Pediatrics Division of Cardiology University of California San Francisco San Francisco CA
| | - Anita Moon-Grady
- Department of Pediatrics Division of Cardiology University of California San Francisco San Francisco CA
| | - A James Barkovich
- Department of Radiology and Biomedical Imaging University of California San Francisco San Francisco CA
| | - Orit Glenn
- Department of Radiology and Biomedical Imaging University of California San Francisco San Francisco CA
| | - Patrick McQuillen
- Department of Pediatrics, Division of Critical Care University of California San Francisco San Francisco CA
| | - Jing Liu
- Department of Radiology and Biomedical Imaging University of California San Francisco San Francisco CA
| |
Collapse
|
12
|
Youn SW, Lee J. From 2D to 4D Phase-Contrast MRI in the Neurovascular System: Will It Be a Quantum Jump or a Fancy Decoration? J Magn Reson Imaging 2020; 55:347-372. [PMID: 33236488 DOI: 10.1002/jmri.27430] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 10/20/2020] [Accepted: 10/21/2020] [Indexed: 12/16/2022] Open
Abstract
Considering the crosstalk between the flow and vessel wall, hemodynamic assessment of the neurovascular system may offer a well-integrated solution for both diagnosis and management by adding prognostic significance to the standard CT/MR angiography. 4D flow MRI or time-resolved 3D velocity-encoded phase-contrast MRI has long been promising for the hemodynamic evaluation of the great vessels, but challenged in clinical studies for assessing intracranial vessels with small diameter due to long scan times and low spatiotemporal resolution. Current accelerated MRI techniques, including parallel imaging with compressed sensing and radial k-space undersampling acquisitions, have decreased scan times dramatically while preserving spatial resolution. 4D flow MRI visualized and measured 3D complex flow of neurovascular diseases such as aneurysm, arteriovenous shunts, and atherosclerotic stenosis using parameters including flow volume, velocity vector, pressure gradients, and wall shear stress. In addition to the noninvasiveness of the phase contrast technique and retrospective flow measurement through the wanted windows of the analysis plane, 4D flow MRI has shown several advantages over Doppler ultrasound or computational fluid dynamics. The evaluation of the flow status and vessel wall can be performed simultaneously in the same imaging modality. This article is an overview of the recent advances in neurovascular 4D flow MRI techniques and their potential clinical applications in neurovascular disease. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY STAGE: 3.
Collapse
Affiliation(s)
- Sung Won Youn
- Department of Radiology, Catholic University of Daegu School of Medicine, Daegu, Korea
| | - Jongmin Lee
- Department of Radiology and Biomedical Engineering, Kyungpook National University School of Medicine, Daegu, Korea
| |
Collapse
|
13
|
Eisenmenger LB, Rivera-Rivera LA, Johnson KM, Drolet BA. Utilisation of advanced MRI techniques to understand neurovascular complications of PHACE syndrome: a case of arterial stenosis and dissection. BMJ Case Rep 2020; 13:13/9/e235992. [PMID: 32928832 PMCID: PMC7490943 DOI: 10.1136/bcr-2020-235992] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
PHACE syndrome is a rare disorder with posterior fossa brain malformations, segmental infantile haemangiomas, arterial anomalies, cardiac defects and eye anomalies. Cerebral and cervical arterial abnormalities occur commonly in these patients, predisposing subjects with PHACE syndrome to neurovascular complications including migraine-like headaches, moyamoya vasculopathy, arterial dissection and arterial ischaemia stroke. We leveraged institutional MRI protocols developed for adult neurovascular disease to better elucidate the pathogenesis of the arterial alternations observed in PHACE. Using high-resolution vessel wall and 4D flow MRI, we demonstrated enhancement, focal dissection and altered blood flow in a 7-year-old girl with PHACE syndrome. This is the first-time vessel wall imaging has been used to detail the known arterial changes in PHACE, and these findings may indicate that progressive vascular narrowing and vessel wall changes/inflammation are a factor in chronic headaches and other arterial complications seen in subjects with PHACE syndrome.
Collapse
Affiliation(s)
| | | | - Kevin M Johnson
- Radiology, University of Wisconsin, Madison, Wisconsin, USA.,Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
| | - Beth A Drolet
- Dermatology, University of Wisconsin, Madison, Wisconsin, USA
| |
Collapse
|
14
|
Callen AL, Caton MT, Rutledge C, Raper D, Narvid J, Villanueva-Meyer JE, Abla A. The Effect of Extracranial-to-Intracranial Bypass on Cerebral Vasoreactivity: A 4D Flow MRI Pilot Study. J Neuroimaging 2020; 30:587-592. [PMID: 32862480 DOI: 10.1111/jon.12776] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 08/11/2020] [Accepted: 08/12/2020] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND AND PURPOSE Extracranial-to-intracranial (EC-IC) surgical bypass improves cerebral blood flow (CBF) and cerebrovascular vasoreactivity (CVR) for patients with carotid occlusion. Bypass graft patency and contribution of the graft to the postoperative increase in CVR are challenging to assess. To assess the effectiveness of 4D flow magnetic resonance imaging (MRI) to evaluate bypass graft patency and flow augmentation through the superficial temporal artery (STA) before and after EC-IC bypass. METHODS Three consecutive patients undergoing EC-IC bypass for carotid occlusion were evaluated pre- and postoperatively using CVR testing with pre- and poststimulus 4D flow-MRI for assessment of the bypass graft and intracranial vasculature. RESULTS Preoperatively, 2 patients (patients 1 and 3) did not augment flow through either native STA. The third, who had evidence of extensive native EC-IC collateralization on digital subtraction angiography (DSA), did augment flow through the STA preoperatively (CVR = 1). Postoperatively, all patients demonstrated CVR > 1 on the side of bypass. The patient who had CVR > 1 preoperatively demonstrated the greatest increase in resting postoperative graft flow (from 40 to 130 mL/minute), but the smallest CVR, with a poststimulus graft flow of 160 mL/minute (CVR = 1.2). The 2 patients who did not demonstrate augmentation of graft flow preoperatively augmented postoperatively from 10 to 20 mL/minute (CVR = 2.0) and 10-80 mL/minute (CVR = 8.0), respectively. Intracranial flow was simultaneously interrogated. Two patients demonstrated mild reductions in resting flow velocities in all interrogated vessels immediately following bypass. The patient who underwent CVR testing on postoperative day 48 demonstrated a stable or increased flow rate in most intracranial vessels. CONCLUSION Four-dimensional flow MRI allows for noninvasive, simultaneous interrogation of the intra- and extracranial arterial vasculature during CVR testing, and reveals unique paradigms in cerebrovascular physiology. Observing these flow patterns may aid in improved patient selection and more detailed postoperative evaluation for patients undergoing EC-IC bypass.
Collapse
Affiliation(s)
- Andrew L Callen
- Department of Radiology, University of Colorado Anschutz Medical Campus, Denver, CO
| | - Michael T Caton
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA
| | - Caleb Rutledge
- Department of Neurological Surgery, University of California San Francisco, San Francisco, CA
| | - Daniel Raper
- Department of Neurological Surgery, University of California San Francisco, San Francisco, CA
| | - Jared Narvid
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA
| | - Javier E Villanueva-Meyer
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA
| | - Adib Abla
- Department of Neurological Surgery, University of California San Francisco, San Francisco, CA
| |
Collapse
|
15
|
Abstract
Magnetic resonance imaging (MRI) has become an important tool for the clinical evaluation of patients with cardiac and vascular diseases. Since its introduction in the late 1980s, quantitative flow imaging with MRI has become a routine part of standard-of-care cardiothoracic and vascular MRI for the assessment of pathological changes in blood flow in patients with cardiovascular disease. More recently, time-resolved flow imaging with velocity encoding along all three flow directions and three-dimensional (3D) anatomic coverage (4D flow MRI) has been developed and applied to enable comprehensive 3D visualization and quantification of hemodynamics throughout the human circulatory system. This article provides an overview of the use of 4D flow applications in different cardiac and vascular regions in the human circulatory system, with a focus on using 4D flow MRI in cardiothoracic and cerebrovascular diseases.
Collapse
Affiliation(s)
- Gilles Soulat
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois 60611, USA
| | - Patrick McCarthy
- Division of Cardiac Surgery, Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois 60611, USA
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois 60611, USA
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois 60208, USA
| |
Collapse
|
16
|
Gottwald LM, Peper ES, Zhang Q, Coolen BF, Strijkers GJ, Nederveen AJ, van Ooij P. Pseudo-spiral sampling and compressed sensing reconstruction provides flexibility of temporal resolution in accelerated aortic 4D flow MRI: A comparison with k-t principal component analysis. NMR IN BIOMEDICINE 2020; 33:e4255. [PMID: 31957927 PMCID: PMC7079056 DOI: 10.1002/nbm.4255] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 12/16/2019] [Accepted: 12/17/2019] [Indexed: 06/10/2023]
Abstract
INTRODUCTION Time-resolved three-dimensional phase contrast MRI (4D flow) of aortic blood flow requires acceleration to reduce scan time. Two established techniques for highly accelerated 4D flow MRI are k-t principal component analysis (k-t PCA) and compressed sensing (CS), which employ either regular or random k-space undersampling. The goal of this study was to gain insights into the quantitative differences between k-t PCA- and CS-derived aortic blood flow, especially for high temporal resolution CS 4D flow MRI. METHODS The scan protocol consisted of both k-t PCA and CS accelerated 4D flow MRI, as well as a 2D flow reference scan through the ascending aorta acquired in 15 subjects. 4D flow scans were accelerated with factor R = 8. For CS accelerated scans, we used a pseudo-spiral Cartesian sampling scheme, which could additionally be reconstructed at higher temporal resolution, resulting in R = 13. 4D flow data were compared with the 2D flow scan in terms of flow, peak flow and stroke volume. A 3D peak systolic voxel-wise velocity and wall shear stress (WSS) comparison between k-t PCA and CS 4D flow was also performed. RESULTS The mean difference in flow/peak flow/stroke volume between the 2D flow scan and the 4D flow CS with R = 8 and R = 13 was 4.2%/9.1%/3.0% and 5.3%/7.1%/1.9%, respectively, whereas for k-t PCA with R = 8 the difference was 9.7%/25.8%/10.4%. In the voxel-by-voxel 4D flow comparison we found 13.6% and 3.5% lower velocity and WSS values of k-t PCA compared with CS with R = 8, and 15.9% and 5.5% lower velocity and WSS values of k-t PCA compared with CS with R = 13. CONCLUSION Pseudo-spiral accelerated 4D flow acquisitions in combination with CS reconstruction provides a flexible choice of temporal resolution. We showed that our proposed strategy achieves better agreement in flow values with 2D reference scans compared with using k-t PCA accelerated acquisitions.
Collapse
Affiliation(s)
- Lukas M. Gottwald
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Eva S. Peper
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Qinwei Zhang
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Bram F. Coolen
- Department of Biomedical Engineering and Physics, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Gustav J. Strijkers
- Department of Biomedical Engineering and Physics, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Aart J. Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Pim van Ooij
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| |
Collapse
|
17
|
Rayz VL, Cohen-Gadol AA. Hemodynamics of Cerebral Aneurysms: Connecting Medical Imaging and Biomechanical Analysis. Annu Rev Biomed Eng 2020; 22:231-256. [PMID: 32212833 DOI: 10.1146/annurev-bioeng-092419-061429] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In the last two decades, numerous studies have conducted patient-specific computations of blood flow dynamics in cerebral aneurysms and reported correlations between various hemodynamic metrics and aneurysmal disease progression or treatment outcomes. Nevertheless, intra-aneurysmal flow analysis has not been adopted in current clinical practice, and hemodynamic factors usually are not considered in clinical decision making. This review presents the state of the art in cerebral aneurysm imaging and image-based modeling, discussing the advantages and limitations of each approach and focusing on the translational value of hemodynamic analysis. Combining imaging and modeling data obtained from different flow modalities can improve the accuracy and fidelity of resulting velocity fields and flow-derived factors that are thought to affect aneurysmal disease progression. It is expected that predictive models utilizing hemodynamic factors in combination with patient medical history and morphological data will outperform current risk scores and treatment guidelines. Possible future directions include novel approaches enabling data assimilation and multimodality analysis of cerebral aneurysm hemodynamics.
Collapse
Affiliation(s)
- Vitaliy L Rayz
- Weldon School of Biomedical Engineering and School of Mechanical Engineering, Purdue University, West Lafayette, Indiana 47907, USA;
| | - Aaron A Cohen-Gadol
- Department of Neurosurgery, Indiana University School of Medicine, Indianapolis, Indiana 46202, USA.,Goodman Campbell Brain and Spine, Carmel, Indiana 46032, USA
| |
Collapse
|
18
|
Liu J, Wang Y, Wen Z, Feng L, Lima APS, Mahadevan VS, Bolger A, Saloner D, Ordovas K. Extending Cardiac Functional Assessment with Respiratory-Resolved 3D Cine MRI. Sci Rep 2019; 9:11563. [PMID: 31399608 PMCID: PMC6689015 DOI: 10.1038/s41598-019-47869-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2018] [Accepted: 07/25/2019] [Indexed: 01/23/2023] Open
Abstract
This study aimed to develop a cardiorespiratory-resolved 3D magnetic resonance imaging (5D MRI: x-y-z-cardiac-respiratory) approach based on 3D motion tracking for investigating the influence of respiration on cardiac ventricular function. A highly-accelerated 2.5-minute sparse MR protocol was developed for a continuous acquisition of cardiac images through multiple cardiac and respiratory cycles. The heart displacement along respiration was extracted using a 3D image deformation algorithm, and this information was used to cluster the acquired data into multiple respiratory phases. The proposed approach was tested in 15 healthy volunteers (7 females). Cardiac function parameters, including the end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF), were measured for the left and right ventricle in both end-expiration and end-inspiration. Although with the proposed 5D cardiac MRI, there were no significant differences (p > 0.05, t-test) between end-expiration and end-inspiration measurements of the cardiac function in volunteers, incremental respiratory motion parameters that were derived from 3D motion tracking, such as the depth, expiration and inspiration distribution, correlated (p < 0.05, correlation coefficient, Mann-Whitney) with those volume-based parameters of cardiac function and varied between genders. The obtained initial results suggested that this new approach allows evaluation of cardiac function during specific respiratory phases. Thus, it can enable investigation of effects related to respiratory variability and better assessment of cardiac function for studying respiratory and/or cardiac dysfunction.
Collapse
Affiliation(s)
- Jing Liu
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, United States.
| | - Yan Wang
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, United States
| | - Zhaoying Wen
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, United States.
- Department of Radiology, Anzhen Hospital, Capital Medical University, Beijing, China.
| | - Li Feng
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States
| | - Ana Paula Santos Lima
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, United States
| | - Vaikom S Mahadevan
- Department of Cardiology, University of California San Francisco, San Francisco, California, United States
| | - Ann Bolger
- Department of Cardiology, University of California San Francisco, San Francisco, California, United States
| | - David Saloner
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, United States
- Radiology Service, VA Medical Center, San Francisco, California, United States
| | - Karen Ordovas
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, United States
| |
Collapse
|
19
|
Bollache E, Knott KD, Jarvis K, Boubertakh R, Dolan RS, Camaioni C, Collins L, Scully P, Rabin S, Treibel T, Carr JC, van Ooij P, Collins JD, Geiger J, Moon JC, Barker AJ, Petersen SE, Markl M. Two-Minute k-Space and Time-accelerated Aortic Four-dimensional Flow MRI: Dual-Center Study of Feasibility and Impact on Velocity and Wall Shear Stress Quantification. Radiol Cardiothorac Imaging 2019; 1:e180008. [PMID: 32076666 DOI: 10.1148/ryct.2019180008] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2018] [Revised: 03/12/2019] [Accepted: 04/23/2019] [Indexed: 01/12/2023]
Abstract
Purpose To investigate the two-center feasibility of highly k-space and time (k-t)-accelerated 2-minute aortic four-dimensional (4D) flow MRI and to evaluate its performance for the quantification of velocities and wall shear stress (WSS). Materials and Methods This cross-sectional study prospectively included 68 participants (center 1, 11 healthy volunteers [mean age ± standard deviation, 61 years ± 15] and 16 patients with aortic disease [mean age, 60 years ± 10]; center 2, 14 healthy volunteers [mean age, 38 years ± 13] and 27 patients with aortic or cardiac disease [mean age, 78 years ± 18]). Each participant underwent highly accelerated 4D flow MRI (k-t acceleration, acceleration factor of 5) of the thoracic aorta. For comparison, conventional 4D flow MRI (acceleration factor of 2) was acquired in the participants at center 1 (n = 27). Regional aortic peak systolic velocities and three-dimensional WSS were quantified. Results k-t-accelerated scan times (center 1, 2:03 minutes ± 0:29; center 2, 2:06 minutes ± 0:20) were significantly reduced compared with conventional 4D flow MRI (center 1, 12:38 minutes ± 2:25; P < .0001). Overall good agreement was found between the two techniques (absolute differences ≤15%), but proximal aortic WSS was significantly underestimated in patients by using k-t-accelerated 4D flow when compared with conventional 4D flow (P ≤ .03). k-t-accelerated 4D flow MRI was reproducible (intra- and interobserver intraclass correlation coefficient ≥0.98) and identified significantly increased peak velocities and WSS in patients with stenotic (P ≤ .003) or bicuspid (P ≤ .04) aortic valves compared with healthy volunteers. In addition, k-t-accelerated 4D flow MRI-derived velocities and WSS were inversely related to age (r ≥-0.53; P ≤ .03) over all healthy volunteers. Conclusion k-t-accelerated aortic 4D flow MRI providing 2-minute scan times was feasible and reproducible at two centers. Although consistent healthy aging- and disease-related changes in aortic hemodynamics were observed, care should be taken when considering WSS, which can be underestimated in patients.© RSNA, 2019See also the commentary by François in this issue.
Collapse
Affiliation(s)
- Emilie Bollache
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Kristopher D Knott
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Kelly Jarvis
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Redha Boubertakh
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Ryan Scott Dolan
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Claudia Camaioni
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Louise Collins
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Paul Scully
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Sydney Rabin
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Thomas Treibel
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - James C Carr
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Pim van Ooij
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Jeremy D Collins
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Julia Geiger
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - James C Moon
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Alex J Barker
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Steffen E Petersen
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| | - Michael Markl
- Department of Radiology, Northwestern University, Feinberg School of Medicine, 737 N Michigan Ave, Suite 1600, Chicago, IL 60611 (E.B., K.J., R.S.D., L.C., S.R., J.C.C., J.D.C., A.J.B., M.M.); Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, Paris, France (E.B.); Barts Heart Centre, London, England (K.D.K., R.B., C.C., P.S., T.T., J.C.M., S.E.P.); Institute of Cardiovascular Science, University College London, London, England (K.D.K., P.S., T.T., J.C.M.); Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands (P.v.O.); Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland (J.G.); NIHR Barts Biomedical Research Unit, William Harvey Research Institute, Queen Mary University of London, London, England (S.E.P.); and Department of Biomedical Engineering, Northwestern University, McCormick School of Engineering, Evanston, Ill (M.M.)
| |
Collapse
|
20
|
Lin Z, Zhang X, Guo L, Wang K, Jiang Y, Hu X, Huang Y, Wei J, Ma S, Liu Y, Zhu L, Zhuo Z, Liu J, Wang X. Clinical feasibility study of 3D intracranial magnetic resonance angiography using compressed sensing. J Magn Reson Imaging 2019; 50:1843-1851. [PMID: 30980468 DOI: 10.1002/jmri.26752] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Accepted: 04/02/2019] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Compressed sensing (CS) has been widely used to improve the speed of MRI, but the feasibility of application in 3D intracranial MR angiography (MRA) needs to be evaluated in clinical practice. PURPOSE To evaluate the clinical feasibility of CS-MRA in comparison with conventional 3D-MRA (Con-MRA). STUDY TYPE Retrospective. SUBJECTS Forty-nine consecutive patients with suspected intracranial arterial disease. FIELD STRENGTH/SEQUENCE 3T MRI. 3D time-of-flight (TOF) MRA using a CS algorithm and conventional 3D TOF MRA scan. ASSESSMENT Three radiologists (4, 11, and 12 years of experience in neuroradiology) independently assessed the image quality, vascular lesions, and variations of intracranial arteries of both CS-MRA and Con-MRA, respectively. STATISTICAL TESTS The Kendall W test was performed to assess the interobserver agreement of image quality and intracranial arterial stenosis. A nonparametric test (Wilcoxon test) was used for comparison of the image quality and definition of the external carotid artery (ECA). Weighted kappa analysis was performed for the interstudy agreement of intracranial arterial stenosis. The aneurysm, decreased branches, congenital hypoplasia, absence, and variant branching of intracranial arteries were observed and evaluated for interobserver agreement and interstudy agreement by kappa analysis. Paired-t-tests for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were conducted. RESULTS Image quality is better for CS-MRA compared with Con-MRA with significance (Z = -3.710 to -2.673, with P < 0.01). The interstudy agreement of lesion and variation of intracranial arteries assessment for each observer was excellent. The SNR and CNR were significantly higher in CS-MRA compared with Con-MRA (P < 0.001). The definition of ECA of CS-MRA was significantly better (Z = -4.9, P < 0.001). DATA CONCLUSION CS-MRA showed significantly higher image quality with less blur, comparable image diagnostic performance of intracranial arteries, and better display of ECA than Con-MRA. LEVEL OF EVIDENCE 3 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019;50:1843-1851.
Collapse
Affiliation(s)
- Zhiyong Lin
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Xiaodong Zhang
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Li Guo
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Ke Wang
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Yuan Jiang
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Xiaoyu Hu
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Yong Huang
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Juan Wei
- Philips Research China, Shanghai, China
| | - Shuai Ma
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Yi Liu
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Lina Zhu
- Department of Radiology, Peking University First Hospital, Beijing, China
| | | | - Jing Liu
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Xiaoying Wang
- Department of Radiology, Peking University First Hospital, Beijing, China
| |
Collapse
|
21
|
Vali A, Aristova M, Vakil P, Abdalla R, Prabhakaran S, Markl M, Ansari SA, Schnell S. Semi-automated analysis of 4D flow MRI to assess the hemodynamic impact of intracranial atherosclerotic disease. Magn Reson Med 2019; 82:749-762. [PMID: 30924197 DOI: 10.1002/mrm.27747] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Revised: 02/03/2019] [Accepted: 03/02/2019] [Indexed: 01/02/2023]
Abstract
PURPOSE This study evaluated the feasibility of using 4D flow MRI and a semi-automated analysis tool to assess the hemodynamic impact of intracranial atherosclerotic disease (ICAD). The ICAD impact was investigated by evaluating pressure drop (PD) at the atherosclerotic stenosis and changes in cerebral blood flow distribution in patients compared to healthy controls. METHODS Dual-venc 4D flow MRI was acquired in 25 healthy volunteers and 16 ICAD patients (ICA, N = 3; MCA, N = 13) with mild (<50%), moderate (50-69%), or severe (>70%) intracranial stenosis. A semi-automated analysis tool was developed to quantify velocity and flow from 4D flow MRI and to evaluate cerebral blood flow redistribution. PD at stenosis was estimated using the Bernoulli equation. The PD calculation was examined by an in vitro phantom study against flow simulations. RESULTS Flow analysis in controls indicated symmetry in blood flow rate (FR) and peak velocity (PV) between the brain hemispheres. For patients, PV in the affected hemisphere was significantly (65%) higher than the normal side (P = 0.002). However, FR to both hemispheres of the brain was the same. The PD depicted significant correlation with PV asymmetry in patients (ρ = 0.67 and P = 0.02), and it was significantly higher for severe compared to moderate stenosis (3.73 vs. 2.30 mm Hg, P = 0.02). CONCLUSION 4D flow MRI quantification enables assessment of the hemodynamic impact of ICAD. The significant difference of the PD between patients with severe and moderate stenosis and its correlation with PV asymmetry suggest that PD may be a pertinent hemodynamic biomarker to evaluate ICAD.
Collapse
Affiliation(s)
- Alireza Vali
- Department of Radiology, Northwestern University, Chicago, Illinois
| | - Maria Aristova
- Department of Radiology, Northwestern University, Chicago, Illinois.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois
| | - Parmede Vakil
- Department of Radiology, Northwestern University, Chicago, Illinois.,Department of Neurological Surgery, Northwestern University, Chicago, Illinois
| | - Ramez Abdalla
- Department of Radiology, Northwestern University, Chicago, Illinois.,Department of Neurological Surgery, Northwestern University, Chicago, Illinois
| | | | - Michael Markl
- Department of Radiology, Northwestern University, Chicago, Illinois.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois
| | - Sameer A Ansari
- Department of Radiology, Northwestern University, Chicago, Illinois.,Department of Neurology, Northwestern University, Chicago, Illinois.,Department of Neurological Surgery, Northwestern University, Chicago, Illinois
| | - Susanne Schnell
- Department of Radiology, Northwestern University, Chicago, Illinois
| |
Collapse
|
22
|
Loecher M, Magrath P, Aliotta E, Ennis DB. Time‐optimized 4D phase contrast MRI with real‐time convex optimization of gradient waveforms and fast excitation methods. Magn Reson Med 2019; 82:213-224. [DOI: 10.1002/mrm.27716] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Revised: 02/01/2019] [Accepted: 02/04/2019] [Indexed: 11/05/2022]
Affiliation(s)
- Michael Loecher
- Department of Radiological Sciences University of California Los Angeles California
| | - Patrick Magrath
- Department of Bioengineering University of California Los Angeles California
| | - Eric Aliotta
- Department of Biomedical Physics University of California Los Angeles California
| | - Daniel B. Ennis
- Department of Radiological Sciences University of California Los Angeles California
- Department of Bioengineering University of California Los Angeles California
- Department of Biomedical Physics University of California Los Angeles California
| |
Collapse
|
23
|
Wang Y, Zhang Y, Xuan W, Kao E, Cao P, Tian B, Ordovas K, Saloner D, Liu J. Fully automatic segmentation of 4D MRI for cardiac functional measurements. Med Phys 2018; 46:180-189. [PMID: 30352129 DOI: 10.1002/mp.13245] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Revised: 09/10/2018] [Accepted: 09/12/2018] [Indexed: 11/05/2022] Open
Abstract
PURPOSE Segmentation of cardiac medical images, an important step in measuring cardiac function, is usually performed either manually or semiautomatically. Fully automatic segmentation of the left ventricle (LV), the right ventricle (RV) as well as the myocardium of three-dimensional (3D) magnetic resonance (MR) images throughout the entire cardiac cycle (four-dimensional, 4D), remains challenging. This study proposes a deformable-based segmentation methodology for efficiently segmenting 4D (3D + t) cardiac MR images. METHODS The proposed methodology first used the Hough transform and the local Gaussian distribution method (LGD) to segment the LV endocardial contours from cardiac MR images. Following this, a novel level set-based shape prior method was applied to generate the LV epicardial contours and the RV boundary. RESULTS This automatic image segmentation approach has been applied to studies on 17 subjects. The results demonstrated that the proposed method was efficient compared to manual segmentation, achieving a segmentation accuracy with average Dice values of 88.62 ± 5.47%, 87.35 ± 7.26%, and 82.63 ± 6.22% for the LV endocardial, LV epicardial, and RV contours, respectively. CONCLUSIONS We have presented a method for accurate LV and RV segmentation. Compared to three existing methods, the proposed method can successfully segment the LV and yield the highest Dice value. This makes it an option for clinical assessment of the volume, size, and thickness of the ventricles.
Collapse
Affiliation(s)
- Yan Wang
- Department of Radiology, University of California San Francisco, San Francisco, CA, 94121, USA
| | - Yue Zhang
- Department of Surgery, University of California San Francisco, San Francisco, CA, 94121, USA.,Veteran Affairs Medical Center, San Francisco, CA, 94121, USA
| | - Wanling Xuan
- The Ohio State University Wexner Medical Center, Columbus, Ohio, 43210, USA
| | - Evan Kao
- Department of Radiology, University of California San Francisco, San Francisco, CA, 94121, USA.,University of California Berkeley, Berkeley, CA, 94720, USA
| | - Peng Cao
- Department of Radiology, University of California San Francisco, San Francisco, CA, 94107, USA
| | - Bing Tian
- Department of Radiology, Changhai Hospital, Shanghai, 200433, China
| | - Karen Ordovas
- Department of Radiology, University of California San Francisco, San Francisco, CA, 94121, USA
| | - David Saloner
- Department of Radiology, University of California San Francisco, San Francisco, CA, 94121, USA.,Department of Surgery, University of California San Francisco, San Francisco, CA, 94121, USA
| | - Jing Liu
- Department of Radiology, University of California San Francisco, San Francisco, CA, 94108, USA
| |
Collapse
|
24
|
Zhu C, Tian B, Chen L, Eisenmenger L, Raithel E, Forman C, Ahn S, Laub G, Liu Q, Lu J, Liu J, Hess C, Saloner D. Accelerated whole brain intracranial vessel wall imaging using black blood fast spin echo with compressed sensing (CS-SPACE). MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2017; 31:457-467. [PMID: 29209856 DOI: 10.1007/s10334-017-0667-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Revised: 11/16/2017] [Accepted: 11/22/2017] [Indexed: 12/15/2022]
Abstract
OBJECTIVE Develop and optimize an accelerated, high-resolution (0.5 mm isotropic) 3D black blood MRI technique to reduce scan time for whole-brain intracranial vessel wall imaging. MATERIALS AND METHODS A 3D accelerated T1-weighted fast-spin-echo prototype sequence using compressed sensing (CS-SPACE) was developed at 3T. Both the acquisition [echo train length (ETL), under-sampling factor] and reconstruction parameters (regularization parameter, number of iterations) were first optimized in 5 healthy volunteers. Ten patients with a variety of intracranial vascular disease presentations (aneurysm, atherosclerosis, dissection, vasculitis) were imaged with SPACE and optimized CS-SPACE, pre and post Gd contrast. Lumen/wall area, wall-to-lumen contrast ratio (CR), enhancement ratio (ER), sharpness, and qualitative scores (1-4) by two radiologists were recorded. RESULTS The optimized CS-SPACE protocol has ETL 60, 20% k-space under-sampling, 0.002 regularization factor with 20 iterations. In patient studies, CS-SPACE and conventional SPACE had comparable image scores both pre- (3.35 ± 0.85 vs. 3.54 ± 0.65, p = 0.13) and post-contrast (3.72 ± 0.58 vs. 3.53 ± 0.57, p = 0.15), but the CS-SPACE acquisition was 37% faster (6:48 vs. 10:50). CS-SPACE agreed with SPACE for lumen/wall area, ER measurements and sharpness, but marginally reduced the CR. CONCLUSION In the evaluation of intracranial vascular disease, CS-SPACE provides a substantial reduction in scan time compared to conventional T1-weighted SPACE while maintaining good image quality.
Collapse
Affiliation(s)
- Chengcheng Zhu
- Department of Radiology and Biomedical Imaging, University of California, San Francisco (UCSF), San Francisco, CA, USA.
| | - Bing Tian
- Department of Radiology, Changhai Hospital, Shanghai, China
| | - Luguang Chen
- Department of Radiology, Changhai Hospital, Shanghai, China
| | - Laura Eisenmenger
- Department of Radiology and Biomedical Imaging, University of California, San Francisco (UCSF), San Francisco, CA, USA
| | | | | | | | | | - Qi Liu
- Department of Radiology, Changhai Hospital, Shanghai, China
| | - Jianping Lu
- Department of Radiology, Changhai Hospital, Shanghai, China.
| | - Jing Liu
- Department of Radiology and Biomedical Imaging, University of California, San Francisco (UCSF), San Francisco, CA, USA
| | - Christopher Hess
- Department of Radiology and Biomedical Imaging, University of California, San Francisco (UCSF), San Francisco, CA, USA
| | - David Saloner
- Department of Radiology and Biomedical Imaging, University of California, San Francisco (UCSF), San Francisco, CA, USA
| |
Collapse
|