1
|
Kumari M, Gupta V, Kumar N, Arun RK. Microfluidics-Based Nanobiosensors for Healthcare Monitoring. Mol Biotechnol 2024; 66:378-401. [PMID: 37166577 PMCID: PMC10173227 DOI: 10.1007/s12033-023-00760-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Accepted: 04/22/2023] [Indexed: 05/12/2023]
Abstract
Efficient healthcare management demands prompt decision-making based on fast diagnostics tools, astute data analysis, and informatics analysis. The rapid detection of analytes at the point of care is ensured using microfluidics in synergy with nanotechnology and biotechnology. The nanobiosensors use nanotechnology for testing, rapid disease diagnosis, monitoring, and management. In essence, nanobiosensors detect biomolecules through bioreceptors by modulating the physicochemical signals generating an optical and electrical signal as an outcome of the binding of a biomolecule with the help of a transducer. The nanobiosensors are sensitive and selective and play a significant role in the early identification of diseases. This article reviews the detection method used with the microfluidics platform for nanobiosensors and illustrates the benefits of combining microfluidics and nanobiosensing techniques by various examples. The fundamental aspects, and their application are discussed to illustrate the advancement in the development of microfluidics-based nanobiosensors and the current trends of these nano-sized sensors for point-of-care diagnosis of various diseases and their function in healthcare monitoring.
Collapse
Affiliation(s)
- Monika Kumari
- Department of Chemical Engineering, Indian Institute of Technology, NH-44, Jagti, PO Nagrota, Jammu, Jammu & Kashmir, 181221, India
| | - Verruchi Gupta
- School of Biotechnology, Shri Mata Vaishno Devi University, Kakryal, Katra, Jammu & Kashmir, 182320, India
| | - Natish Kumar
- Department of Chemical Engineering, Indian Institute of Technology, NH-44, Jagti, PO Nagrota, Jammu, Jammu & Kashmir, 181221, India
| | - Ravi Kumar Arun
- Department of Chemical Engineering, Indian Institute of Technology, NH-44, Jagti, PO Nagrota, Jammu, Jammu & Kashmir, 181221, India.
| |
Collapse
|
2
|
Feng H, Zhang J, Shu W, Bai X, Song L, Chen Y. Highly Accurate Pneumatically Tunable Optofluidic Distributed Feedback Dye Lasers. MICROMACHINES 2023; 15:68. [PMID: 38258186 PMCID: PMC10820426 DOI: 10.3390/mi15010068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 12/15/2023] [Accepted: 12/19/2023] [Indexed: 01/24/2024]
Abstract
Optofluidic dye lasers integrated into microfluidic chips are promising miniature coherent light sources for biosensing. However, achieving the accurate and efficient tuning of lasers remains challenging. This study introduces a novel pneumatically tunable optofluidic distributed feedback (DFB) dye laser in a multilayer microfluidic chip. The dye laser device integrates microfluidic channels, grating structures, and vacuum chambers. A second-order DFB grating configuration is utilized to ensure single-mode lasing. The application of vacuum pressure to the chambers stretches the soft grating layer, enabling the sensitive tuning of the lasing wavelength at a high resolution of 0.25 nm within a 7.84 nm range. The precise control of pressure and laser tuning is achieved through an electronic regulator. Additionally, the integrated microfluidic channels and optimized waveguide structure facilitate efficient dye excitation, resulting in a low pump threshold of 164 nJ/pulse. This pneumatically tunable optofluidic DFB laser, with its high-resolution wavelength tuning range, offers new possibilities for the development of integrated portable devices for biosensing and spectroscopy.
Collapse
Affiliation(s)
| | | | | | | | | | - Yan Chen
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (H.F.); (J.Z.); (W.S.); (X.B.); (L.S.)
| |
Collapse
|
3
|
Lan Y, Zhou Y, Wu M, Jia C, Zhao J. Microfluidic based single cell or droplet manipulation: Methods and applications. Talanta 2023; 265:124776. [PMID: 37348357 DOI: 10.1016/j.talanta.2023.124776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 05/31/2023] [Accepted: 06/06/2023] [Indexed: 06/24/2023]
Abstract
The isolation of single cell or droplet is first and crucial step to single-cell analysis, which is important for cancer research and diagnostic methods. This review provides an overview of technologies that are currently used or in development to realize the isolation. Microfluidic based manipulation is an emerging technology with the distinct advantages of miniaturization and low cost. Therefore, recent developments in microfluidic isolated methods have attracted extensive attention. We introduced herein five strategies based on microfluid: trap, microfluidic discrete manipulation, bioprinter, capillary and inertial force. For every technology, their basic principles and features were discussed firstly. Then some modified approaches and applications were listed as the extension. Finally, we compared the advantages and drawbacks of these methods, and analyzed the trend of the manipulation based on microfluidics.
Collapse
Affiliation(s)
- Yuwei Lan
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Yang Zhou
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Man Wu
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China.
| | - Chunping Jia
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Jianlong Zhao
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China; Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China; Institute for Stem Cell and Regeneration, Chinese Academy of Sciences, Beijing, 100101, China.
| |
Collapse
|
4
|
Serioli L, Gruzinskyte L, Zappalà G, Hwu ET, Laksafoss TZ, Jensen PL, Demarchi D, Müllertz A, Boisen A, Zór K. Moving perfusion culture and live-cell imaging from lab to disc: proof of concept toxicity assay with AI-based image analysis. LAB ON A CHIP 2023; 23:1603-1612. [PMID: 36790123 DOI: 10.1039/d2lc00984f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
In vitro, cell-based assays are essential in diagnostics and drug development. There are ongoing efforts to establish new technologies that enable real-time detection of cell-drug interaction during culture under flow conditions. Our compact (10 × 10 × 8.5 cm) cell culture and microscope on disc (CMoD) platform aims to decrease the application barriers of existing lab-on-a-chip (LoC) approaches. For the first time in a centrifugal device, (i) cells were cultured for up to six days while a spindle motor facilitated culture medium perfusion, and (ii) an onboard microscope enabled live bright-field imaging of cells while the data wirelessly transmitted to a computer. The quantification of cells from the acquired images was done using artificial intelligence (AI) software. After optimization, the obtained cell viability data from the AI-based image analysis proved to correlate well with data collected from commonly used image analysis software. The CMoD was also suitable for conducting a proof-of-concept toxicity assay with HeLa cells under continuous flow. The half-maximal inhibitory time (IT50) for various concentrations of doxorubicin (DOX) in the case of HeLa cells in flow, was shown to be lower than the IT50 obtained from a static cytotoxicity assay, indicating a faster onset of cell death in flow. The CMoD proved to be easy to handle, enabled cell culture and monitoring without assistance, and is a promising tool for examining the dynamic processes of cells in real-time assays.
Collapse
Affiliation(s)
- Laura Serioli
- The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Denmark.
- BioInnovation Institute Foundation, Copenhagen N 2800, Denmark
| | - Lina Gruzinskyte
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
- The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Denmark.
| | - Giulia Zappalà
- The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Denmark.
- Department of Electronics and Telecommunications, Politecnico di Torino, Italy
| | - En Te Hwu
- The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Denmark.
| | - Trygvi Zachariassen Laksafoss
- The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Denmark.
| | | | - Danilo Demarchi
- Department of Electronics and Telecommunications, Politecnico di Torino, Italy
| | - Anette Müllertz
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
- The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Denmark.
| | - Anja Boisen
- The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Denmark.
- BioInnovation Institute Foundation, Copenhagen N 2800, Denmark
| | - Kinga Zór
- The Danish National Research Foundation and Villum Foundation's Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Denmark.
- BioInnovation Institute Foundation, Copenhagen N 2800, Denmark
| |
Collapse
|
5
|
Chen L, Liang S, Chen Z, Liang X, Chen Q. Electrically Tunable Lenses for Imaging and Light Manipulation. MICROMACHINES 2023; 14:319. [PMID: 36838021 PMCID: PMC9964308 DOI: 10.3390/mi14020319] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 01/18/2023] [Accepted: 01/21/2023] [Indexed: 06/18/2023]
Abstract
Optofluidics seamlessly combines optics and microfluidics together to construct novel devices for microsystems, providing flexible reconfigurability and high compatibility. By taking advantage of mature electronic fabrication techniques and flexible regulation of microfluidics, electrically actuated optofluidics has achieved fantastic optical functions. Generally, the optical function is achieved by electrically modulating the interfaces or movements of microdroplets inside a small chamber. The high refractive index difference (~0.5) at the interfaces between liquid/air or liquid/liquid makes unprecedented optical tunability a reality. They are suitable for optical imaging devices, such as microscope and portable electronic. This paper will review the working principle and recent development of electrical optofluidic devices by electrowetting and dielectrophoresis, including optical lens/microscope, beam steering and in-plane light manipulation. Some methods to improve the lens performance are reviewed. In addition, the applications of electrical microfluidics are also discussed. In order to stimulate the development of electrically controlled liquid lens, two novel designs derived from electrowetting and dielectrophoresis are introduced in this paper.
Collapse
Affiliation(s)
- Lijun Chen
- School of Microelectronics Science and Technology, Sun Yat-sen University, Zhuhai 519082, China
| | - Shijie Liang
- School of Microelectronics Science and Technology, Sun Yat-sen University, Zhuhai 519082, China
| | - Zhenshi Chen
- School of Electronic Information, Huzhou College, Huzhou 313000, China
| | - Xifa Liang
- School of Microelectronics Science and Technology, Sun Yat-sen University, Zhuhai 519082, China
| | - Qingming Chen
- School of Microelectronics Science and Technology, Sun Yat-sen University, Zhuhai 519082, China
- Guangdong Provincial Key Laboratory of Optoelectronic Information Processing Chips and Systems, Sun Yat-sen University, Guangzhou 511400, China
| |
Collapse
|
6
|
Bobkova V, Stegemann J, Droop R, Otte E, Denz C. Optical grinder: sorting of trapped particles by orbital angular momentum. OPTICS EXPRESS 2021; 29:12967-12975. [PMID: 33985042 DOI: 10.1364/oe.419876] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Accepted: 03/11/2021] [Indexed: 06/12/2023]
Abstract
We customize a transversely structured, tunable light landscape on the basis of orbital angular momentum (OAM)-carrying beams for the purpose of advanced optical manipulation. Combining Laguerre-Gaussian (LG) modes with helical phase fronts of opposite OAM handedness, counter-rotating transfer of OAM is enabled in a concentric intensity structure, creating a dynamic "grinding" scenario on dielectric microparticles. We demonstrate the ability to trap and rotate silica spheres of various sizes and exploit the light fields' feature to spatially separate trapped objects by their size. We show the adaptability of the light field depending on the chosen LG mode indices, allowing on-demand tuning of the trapping potential and sorting criteria. The versatility of our approach for biomedical application is examined by spatial discriminating yeast cells and silica spheres of distinct diameter.
Collapse
|
7
|
Qi J, Li W, Chu W, Yu J, Wu M, Liang Y, Yin D, Wang P, Wang Z, Wang M, Cheng Y. A Microfluidic Mixer of High Throughput Fabricated in Glass Using Femtosecond Laser Micromachining Combined with Glass Bonding. MICROMACHINES 2020; 11:E213. [PMID: 32093086 PMCID: PMC7074671 DOI: 10.3390/mi11020213] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2019] [Revised: 02/14/2020] [Accepted: 02/18/2020] [Indexed: 11/16/2022]
Abstract
We demonstrate a microfluidic mixer of high mixing efficiency in fused silica substrate using femtosecond laser-induced wet etching and hydroxide-catalysis bonding method. The micromixer has a three-dimensional geometry, enabling efficient mixing based on Baker's transformation principle. The cross-sectional area of the fabricated micromixer was 0.5 × 0.5 mm2, enabling significantly promotion of the throughput of the micromixer. The performance of the fabricated micromixers was evaluated by mixing up blue and yellow ink solutions with a flow rate as high as 6 mL/min.
Collapse
Affiliation(s)
- Jia Qi
- State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China; (J.Q.); (W.L.); (J.Y.); (D.Y.); (P.W.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wenbo Li
- State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China; (J.Q.); (W.L.); (J.Y.); (D.Y.); (P.W.)
- University of Chinese Academy of Sciences, Beijing 100049, China
- School of Physical Science and Technology, ShanghaiTech University, Shanghai 200031, China
| | - Wei Chu
- XXL-The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (M.W.); (Y.L.); (Z.W.); (M.W.)
| | - Jianping Yu
- State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China; (J.Q.); (W.L.); (J.Y.); (D.Y.); (P.W.)
- University of Chinese Academy of Sciences, Beijing 100049, China
- School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
| | - Miao Wu
- XXL-The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (M.W.); (Y.L.); (Z.W.); (M.W.)
| | - Youting Liang
- XXL-The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (M.W.); (Y.L.); (Z.W.); (M.W.)
| | - Difeng Yin
- State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China; (J.Q.); (W.L.); (J.Y.); (D.Y.); (P.W.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Peng Wang
- State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China; (J.Q.); (W.L.); (J.Y.); (D.Y.); (P.W.)
- University of Chinese Academy of Sciences, Beijing 100049, China
- School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
| | - Zhenhua Wang
- XXL-The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (M.W.); (Y.L.); (Z.W.); (M.W.)
| | - Min Wang
- XXL-The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (M.W.); (Y.L.); (Z.W.); (M.W.)
| | - Ya Cheng
- State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China; (J.Q.); (W.L.); (J.Y.); (D.Y.); (P.W.)
- XXL-The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (M.W.); (Y.L.); (Z.W.); (M.W.)
- State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China
- Collaborative Innovation Center of Light Manipulations and Applications, Shandong Normal University, Jinan 250358, China
| |
Collapse
|
8
|
He X, Xu Q, Chen R, Zhu X, Liao Q, Ye D, Zhang B, Jiao L, Li W. IR laser induced phase change behaviors of the NaCl solution in the microchannel. Chem Eng Sci 2018. [DOI: 10.1016/j.ces.2018.05.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
9
|
Wang Z, Chen R, Zhu X, Liao Q, Ye D, Zhang B, Jiao L. Thermal analysis of the photothermal effect based droplet microfluidic system. Chem Eng Sci 2018. [DOI: 10.1016/j.ces.2018.04.049] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
10
|
Chen Q, Li T, Li Z, Long J, Zhang X. Optofluidic Tunable Lenses for In-Plane Light Manipulation. MICROMACHINES 2018; 9:E97. [PMID: 30424031 PMCID: PMC6187471 DOI: 10.3390/mi9030097] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 02/10/2018] [Accepted: 02/11/2018] [Indexed: 12/19/2022]
Abstract
Optofluidics incorporates optics and microfluidics together to construct novel devices for microsystems, providing flexible reconfigurability and high compatibility. Among many novel devices, a prominent one is the in-plane optofluidic lens. It manipulates the light in the plane of the substrate, upon which the liquid sample is held. Benefiting from the compatibility, the in-plane optofluidic lenses can be incorporated into a single chip without complicated manual alignment and promises high integration density. In term of the tunability, the in-plane liquid lenses can be either tuned by adjusting the fluidic interface using numerous microfluidic techniques, or by modulating the refractive index of the liquid using temperature, electric field and concentration. In this paper, the in-plane liquid lenses will be reviewed in the aspects of operation mechanisms and recent development. In addition, their applications in lab-on-a-chip systems are also discussed.
Collapse
Affiliation(s)
- Qingming Chen
- Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong 999077, China.
| | - Tenghao Li
- Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong 999077, China.
| | - Zhaohui Li
- School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou 510275, China.
| | - Jinlin Long
- School of Chemistry and Chemical Engineering, Fuzhou University, Fuzhou 350116, China.
| | - Xuming Zhang
- Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong 999077, China.
- Shenzhen Research Institute of the Hong Kong Polytechnic University, Shenzhen 518057, China.
| |
Collapse
|
11
|
Zulkifli SN, Rahim HA, Lau WJ. Detection of contaminants in water supply: A review on state-of-the-art monitoring technologies and their applications. SENSORS AND ACTUATORS. B, CHEMICAL 2018; 255:2657-2689. [PMID: 32288249 PMCID: PMC7126548 DOI: 10.1016/j.snb.2017.09.078] [Citation(s) in RCA: 86] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2016] [Revised: 08/22/2017] [Accepted: 09/13/2017] [Indexed: 05/12/2023]
Abstract
Water monitoring technologies are widely used for contaminants detection in wide variety of water ecology applications such as water treatment plant and water distribution system. A tremendous amount of research has been conducted over the past decades to develop robust and efficient techniques of contaminants detection with minimum operating cost and energy. Recent developments in spectroscopic techniques and biosensor approach have improved the detection sensitivities, quantitatively and qualitatively. The availability of in-situ measurements and multiple detection analyses has expanded the water monitoring applications in various advanced techniques including successful establishment in hand-held sensing devices which improves portability in real-time basis for the detection of contaminant, such as microorganisms, pesticides, heavy metal ions, inorganic and organic components. This paper intends to review the developments in water quality monitoring technologies for the detection of biological and chemical contaminants in accordance with instrumental limitations. Particularly, this review focuses on the most recently developed techniques for water contaminant detection applications. Several recommendations and prospective views on the developments in water quality assessments will also be included.
Collapse
Affiliation(s)
| | - Herlina Abdul Rahim
- Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
| | - Woei-Jye Lau
- Advanced Membrane Technology Research Centre (AMTEC), Faculty of Chemical and Energy Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
| |
Collapse
|
12
|
Affiliation(s)
- Xilong Yuan
- Department of Chemistry, Queen's University , Kingston, Ontario K7L 3N6, Canada
| | - Richard D Oleschuk
- Department of Chemistry, Queen's University , Kingston, Ontario K7L 3N6, Canada
| |
Collapse
|
13
|
Kopp D, Brender T, Zappe H. All-liquid dual-lens optofluidic zoom system. APPLIED OPTICS 2017; 56:3758-3763. [PMID: 28463264 DOI: 10.1364/ao.56.003758] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
An all-liquid optical zoom system based on two independently controllable liquid lenses positioned inside a single sealed cylindrical housing is demonstrated. This system yielded a zoom ratio of 1.5 for an object distance of 200 mm, an image distance 37 mm, and a corresponding resolution of better than 5 line pairs/mm. With a diameter of 5 mm, a packaged system length of 9.88 mm, and a power consumption of 3.5 mW, the system represents a new generation of ultra-miniaturized optofluidic systems with high functionality, excellent imaging properties, and highly flexible tunability, all with no mechanically moving parts.
Collapse
|
14
|
Gokaltun A, Yarmush ML, Asatekin A, Usta OB. Recent advances in nonbiofouling PDMS surface modification strategies applicable to microfluidic technology. TECHNOLOGY 2017; 5:1-12. [PMID: 28695160 PMCID: PMC5501164 DOI: 10.1142/s2339547817300013] [Citation(s) in RCA: 86] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
In the last decade microfabrication processes including rapid prototyping techniques have advanced rapidly and achieved a fairly mature stage. These advances have encouraged and enabled the use of microfluidic devices by a wider range of users with applications in biological separations and cell and organoid cultures. Accordingly, a significant current challenge in the field is controlling biomolecular interactions at interfaces and the development of novel biomaterials to satisfy the unique needs of the biomedical applications. Poly(dimethylsiloxane) (PDMS) is one of the most widely used materials in the fabrication of microfluidic devices. The popularity of this material is the result of its low cost, simple fabrication allowing rapid prototyping, high optical transparency, and gas permeability. However, a major drawback of PDMS is its hydrophobicity and fast hydrophobic recovery after surface hydrophilization. This results in significant nonspecific adsorption of proteins as well as small hydrophobic molecules such as therapeutic drugs limiting the utility of PDMS in biomedical microfluidic circuitry. Accordingly, here, we focus on recent advances in surface molecular treatments to prevent fouling of PDMS surfaces towards improving its utility and expanding its use cases in biomedical applications.
Collapse
Affiliation(s)
- Aslihan Gokaltun
- Center for Engineering in Medicine at Massachusetts General Hospital, Harvard Medical School, and Shriners Hospital for Children, 51 Blossom St., Boston, MA 02114, USA
- Department of Chemical and Biological Engineering, Tufts University, 4 Colby Street, Medford, MA 02474, USA
- Department of Chemical Engineering, Hacettepe University, 06532, Beytepe, Ankara, Turkey
| | - Martin L Yarmush
- Center for Engineering in Medicine at Massachusetts General Hospital, Harvard Medical School, and Shriners Hospital for Children, 51 Blossom St., Boston, MA 02114, USA
- Department of Biomedical Engineering, Rutgers University, 599 Taylor Rd., Piscataway, NJ 08854, USA
| | - Ayse Asatekin
- Department of Chemical and Biological Engineering, Tufts University, 4 Colby Street, Medford, MA 02474, USA
| | - O Berk Usta
- Center for Engineering in Medicine at Massachusetts General Hospital, Harvard Medical School, and Shriners Hospital for Children, 51 Blossom St., Boston, MA 02114, USA
| |
Collapse
|
15
|
Martin JW, Nieuwoudt MK, Vargas MJT, Bodley OLC, Yohendiran TS, Oosterbeek RN, Williams DE, Cather Simpson M. Raman on a disc: high-quality Raman spectroscopy in an open channel on a centrifugal microfluidic disc. Analyst 2017; 142:1682-1688. [DOI: 10.1039/c6an00874g] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Novel open-channel centrifugal microfluidic disc design affords measurement of high quality Raman spectra of milk for detecting adulterants at point-of-collection.
Collapse
Affiliation(s)
- J. W. Martin
- School of Chemical Sciences
- The University of Auckland
- Auckland
- New Zealand
- The Photon Factory
| | - M. K. Nieuwoudt
- School of Chemical Sciences
- The University of Auckland
- Auckland
- New Zealand
- The Photon Factory
| | - M. J. T. Vargas
- School of Chemical Sciences
- The University of Auckland
- Auckland
- New Zealand
- The Photon Factory
| | - O. L. C. Bodley
- The Photon Factory
- The University of Auckland
- Auckland
- New Zealand
- The MacDiarmid Institute for Advanced Materials and Nanotechnology
| | - T. S. Yohendiran
- The Photon Factory
- The University of Auckland
- Auckland
- New Zealand
- The MacDiarmid Institute for Advanced Materials and Nanotechnology
| | - R. N. Oosterbeek
- The Photon Factory
- The University of Auckland
- Auckland
- New Zealand
- The MacDiarmid Institute for Advanced Materials and Nanotechnology
| | - D. E. Williams
- School of Chemical Sciences
- The University of Auckland
- Auckland
- New Zealand
- The MacDiarmid Institute for Advanced Materials and Nanotechnology
| | - M. Cather Simpson
- School of Chemical Sciences
- The University of Auckland
- Auckland
- New Zealand
- The Photon Factory
| |
Collapse
|
16
|
Pollnau M, Hammer M, Dongre C, Hoekstra HJWM. Combined microfluidic-optical DNA analysis with single-base-pair sizing capability. BIOMEDICAL OPTICS EXPRESS 2016; 7:5201-5207. [PMID: 28018736 PMCID: PMC5175563 DOI: 10.1364/boe.7.005201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Revised: 11/11/2016] [Accepted: 11/11/2016] [Indexed: 06/06/2023]
Abstract
DNA sequencing by microchip capillary electrophoresis (CE) enables cheap, high-speed analysis of low reagent volumes. One of its potential applications is the identification of genomic deletions or insertions associated with genetic illnesses. Detecting single base-pair insertions or deletions from DNA fragments in the diagnostically relevant size range of 150-1000 base-pairs requires a variance of σ2 < 10-3. In a microfluidic chip post-processed by femtosecond-laser writing of an optical waveguide we CE-separated 12 blue-labeled and 23 red-labeled DNA fragments in size. Each set was excited by either of two lasers power-modulated at different frequencies, their fluorescence detected by a photomultiplier, and blue and red signals distinguished by Fourier analysis. We tested different calibration strategies. Choice of the fluorescent label as well as the applied fit function strongly influence the obtained variance, whereas fluctuations between two consecutive experiments are less detrimental in a laboratory environment. We demonstrate a variance of σ2 ≈4 × 10-4, lower than required for the detection of single base-pair insertion or deletion in an optofluidic chip.
Collapse
Affiliation(s)
- Markus Pollnau
- Integrated Optical Microsystems Group, MESA + Institute for Nanotechnology, University of Twente, P. O. Box 217, 7500 AE Enschede, The Netherlands
- Department of Materials and Nano Physics, School of Information and Communication Technology, KTH−Royal Institute of Technology, Electrum 229, Isafjordsgatan 22−24, 16440 Kista, Sweden
| | - Manfred Hammer
- Integrated Optical Microsystems Group, MESA + Institute for Nanotechnology, University of Twente, P. O. Box 217, 7500 AE Enschede, The Netherlands
- Theoretical Electrical Engineering, University of Paderborn, Warburger Strasse 100, 33098 Paderborn, Germany
| | - Chaitanya Dongre
- Integrated Optical Microsystems Group, MESA + Institute for Nanotechnology, University of Twente, P. O. Box 217, 7500 AE Enschede, The Netherlands
| | - Hugo J. W. M. Hoekstra
- Integrated Optical Microsystems Group, MESA + Institute for Nanotechnology, University of Twente, P. O. Box 217, 7500 AE Enschede, The Netherlands
| |
Collapse
|
17
|
Tay A, Pavesi A, Yazdi SR, Lim CT, Warkiani ME. Advances in microfluidics in combating infectious diseases. Biotechnol Adv 2016; 34:404-421. [PMID: 26854743 PMCID: PMC7125941 DOI: 10.1016/j.biotechadv.2016.02.002] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2015] [Revised: 02/03/2016] [Accepted: 02/04/2016] [Indexed: 12/11/2022]
Abstract
One of the important pursuits in science and engineering research today is to develop low-cost and user-friendly technologies to improve the health of people. Over the past decade, research efforts in microfluidics have been made to develop methods that can facilitate low-cost diagnosis of infectious diseases, especially in resource-poor settings. Here, we provide an overview of the recent advances in microfluidic devices for point-of-care (POC) diagnostics for infectious diseases and emphasis is placed on malaria, sepsis and AIDS/HIV. Other infectious diseases such as SARS, tuberculosis, and dengue are also briefly discussed. These infectious diseases are chosen as they contribute the most to disability-adjusted life-years (DALYs) lost according to the World Health Organization (WHO). The current state of research in this area is evaluated and projection toward future applications and accompanying challenges are also discussed.
Collapse
Affiliation(s)
- Andy Tay
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore 138602, Singapore; Department of Biomedical Engineering, National University of Singapore, Singapore 117575, Singapore; Department of Bioengineering, University of California Los Angeles, CA 90025, United States
| | - Andrea Pavesi
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore 138602, Singapore
| | - Saeed Rismani Yazdi
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore 138602, Singapore; Polytechnic University of Milan, Milan 20133, Italy
| | - Chwee Teck Lim
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore 138602, Singapore; Mechanobiology Institute, National University of Singapore, Singapore 117411, Singapore; Department of Biomedical Engineering, National University of Singapore, Singapore 117575, Singapore
| | - Majid Ebrahimi Warkiani
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore 138602, Singapore; School of Mechanical and Manufacturing Engineering, Australian Centre for NanoMedicine, University of New South Wales, Sydney, NSW 2052, Australia.
| |
Collapse
|
18
|
Proskurnin MA, Bendrysheva SN, Smirnova AP. Thermal lens spectrometry in electromigration methods of analysis. JOURNAL OF ANALYTICAL CHEMISTRY 2016. [DOI: 10.1134/s1061934816050105] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
19
|
Fan SK, Lee HP, Chien CC, Lu YW, Chiu Y, Lin FY. Reconfigurable liquid-core/liquid-cladding optical waveguides with dielectrophoresis-driven virtual microchannels on an electromicrofluidic platform. LAB ON A CHIP 2016; 16:847-854. [PMID: 26841828 DOI: 10.1039/c5lc01233c] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
An electrically reconfigurable liquid-core/liquid-cladding (L(2)) optical waveguide with core liquid γ-butyrolactone (GBL, ncore = 1.4341, εcore = 39) and silicone oil (ncladding = 1.401, εcladding = 2.5) as cladding liquid is accomplished using dielectrophoresis (DEP) that attracts and deforms the core liquid with the greater permittivity to occupy the region of strong electric field provided by Teflon-coated ITO electrodes between parallel glass plates. Instead of continuously flowing core and cladding liquids along a physical microchannel, the DEP-formed L(2) optical waveguide guides light in a stationary virtual microchannel that requires liquids of limited volume without constant supply and creates stable liquid/liquid interfaces for efficient light guidance in a simply fabricated microfluidic device. We designed and examined (1) stationary and (2) moving L(2) optical waveguides on the parallel-plate electromicrofluidic platform. In the stationary L-shaped waveguide, light was guided in a GBL virtual microchannel core for a total of 27.85 mm via a 90° bend (radius 5 mm) before exiting from the light outlet of cross-sectional area 100 μm × 100 μm. For the stationary spiral waveguide, light was guided in a GBL core containing Rhodamine 6G (R6G, 1 mM) and through a series of 90° bends with decreasing radii from 5 mm to 2.5 mm. With the stationary straight waveguide, the propagation loss was measured to be 2.09 dB cm(-1) in GBL with R6G (0.01 mM). The moving L-shaped waveguide was implemented on a versatile electromicrofluidic platform on which electrowetting and DEP were employed to generate a precise GBL droplet and form a waveguide core. On sequentially applying appropriate voltage to one of three parallel L-shaped driving electrodes, the GBL waveguide core was shifted; the guided light was switched at a speed of up to 0.929 mm s(-1) (switching period 70 ms, switching rate 14.3 Hz) when an adequate electric signal (173.1 VRMS, 100 kHz) was applied.
Collapse
Affiliation(s)
- Shih-Kang Fan
- Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan.
| | - Hsuan-Ping Lee
- Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan.
| | - Chia-Chi Chien
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu, Taiwan
| | - Yi-Wen Lu
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu, Taiwan
| | - Yi Chiu
- Department of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu, Taiwan
| | - Fan-Yi Lin
- Institute of Photonics Technologies, Department of Electrical Engineering, National Tsing Hua University, Hsinchu, Taiwan
| |
Collapse
|
20
|
Holzner G, Kriel FH, Priest C. Pillar cuvettes: capillary-filled, microliter quartz cuvettes with microscale path lengths for optical spectroscopy. Anal Chem 2015; 87:4757-64. [PMID: 25844800 DOI: 10.1021/acs.analchem.5b00860] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The goal of most analytical techniques is to reduce the lower limit of detection; however, it is sometimes necessary to do the opposite. High sample concentrations or samples with high molar absorptivity (e.g., dyes and metal complexes) often require multiple dilution steps or laborious sample preparation prior to spectroscopic analysis. Here, we demonstrate dilution-free, one-step UV-vis spectroscopic analysis of high concentrations of platinum(IV) hexachloride in a micropillar array, that is, "pillar cuvette". The cuvette is spontaneously filled by wicking of the liquid sample into the micropillar array. The pillar height (thus, the film thickness) defines the optical path length, which was reduced to between 10 and 20 μm in this study (3 orders of magnitude smaller than in a typical cuvette). Only one small droplet (∼2 μL) of sample is required, and the dispensed volume need not be precise or even known to the analyst for accurate spectroscopy measurements. For opaque pillars, we show that absorbance is linearly related to platinum concentration (the Beer-Lambert Law). For fully transparent or semitransparent pillars, the measured absorbance was successfully corrected for the fractional surface coverage of the pillars and the transmittance of the pillars and reference. Thus, both opaque and transparent pillars can be applied to absorbance spectroscopy of high absorptivity, microliter samples. It is also shown here that the pillar array has a useful secondary function as an integrated (in-cuvette) filter for particulates. For pillar cuvette measurements of platinum solutions spiked with 6 μm diameter polystyrene spheres, filtered and unfiltered samples gave identical spectra.
Collapse
Affiliation(s)
- Gregor Holzner
- Ian Wark Research Institute, University of South Australia, Adelaide, SA, Australia
| | | | - Craig Priest
- Ian Wark Research Institute, University of South Australia, Adelaide, SA, Australia
| |
Collapse
|
21
|
Guo J, Chen L, Ai Y, Cheng Y, Li CM, Kang Y, Wang Z. Numerical and experimental characterization of solid-state micropore-based cytometer for detection and enumeration of biological cells. Electrophoresis 2015; 36:737-43. [PMID: 25488493 DOI: 10.1002/elps.201400376] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Revised: 11/25/2014] [Accepted: 11/27/2014] [Indexed: 10/24/2022]
Abstract
Portable diagnostic devices have emerged as important tools in various biomedical applications since they can provide an effective solution for low-cost and rapid clinical diagnosis. In this paper, we present a micropore-based resistive cytometer for the detection and enumeration of biological cells. The proposed device was fabricated on a silicon wafer by a standard microelectromechanical system processing technology, which enables a mass production of the proposed chip. The working principle of this cytometer is based upon a bias potential modulated pulse, originating from the biological particle's physical blockage of the micropore. Polystyrene particles of different sizes (7, 10, and 16 μm) were used to test and calibrate the proposed device. A finite element simulation was developed to predict the bias potential modulated pulse (peak amplitude vs. pulse bandwidth), which can provide critical insight into the design of this microfluidic flow cytometer. Furthermore, HeLa cells (a type of tumor cell lines) spiked in a suspension of blood cells, including red blood cells and white blood cells, were used to assess the performance for detecting and counting tumor cells. The proposed microfluidic flow cytometer is able to provide a promising platform to address the current unmet need for point-of-care clinical diagnosis.
Collapse
Affiliation(s)
- Jinhong Guo
- Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu, P. R. China; Pillar of Engineering Product Development, Singapore University of Technology and Design, Singapore
| | | | | | | | | | | | | |
Collapse
|
22
|
Fujiki M, Donguri Y, Zhao Y, Nakao A, Suzuki N, Yoshida K, Zhang W. Photon magic: chiroptical polarisation, depolarisation, inversion, retention and switching of non-photochromic light-emitting polymers in optofluidic medium. Polym Chem 2015. [DOI: 10.1039/c4py01337a] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A circularly polarised photon hand, l- and r-, was not a deterministic factor for the induced chiroptical sign of π-conjugated polymer aggregates. This anomaly originates from circular dichroism inversion characteristics between shorter and longer π–π* bands.
Collapse
Affiliation(s)
- Michiya Fujiki
- Graduate School of Materials Science
- Nara Institute of Science and Technology
- Ikoma
- Japan
| | - Yuri Donguri
- Graduate School of Materials Science
- Nara Institute of Science and Technology
- Ikoma
- Japan
| | - Yin Zhao
- Suzhou Key Laboratory of Macromolecular Design and Precision Synthesis
- Jiangsu Key Laboratory of Advanced Functional Polymer Design and Application
- College of Chemistry
- Chemical Engineering and Materials Science
- Soochow University
| | - Ayako Nakao
- Graduate School of Materials Science
- Nara Institute of Science and Technology
- Ikoma
- Japan
| | - Nozomu Suzuki
- Graduate School of Materials Science
- Nara Institute of Science and Technology
- Ikoma
- Japan
| | - Kana Yoshida
- Graduate School of Materials Science
- Nara Institute of Science and Technology
- Ikoma
- Japan
| | - Wei Zhang
- Suzhou Key Laboratory of Macromolecular Design and Precision Synthesis
- Jiangsu Key Laboratory of Advanced Functional Polymer Design and Application
- College of Chemistry
- Chemical Engineering and Materials Science
- Soochow University
| |
Collapse
|
23
|
Méance S, Gamby J, Faure M, Kou Q, Haghiri-Gosnet AM. Electrochemiluminescence on-a-chip: Towards a hand-held electrically powered optofluidic source. Talanta 2014; 129:150-4. [DOI: 10.1016/j.talanta.2014.05.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2014] [Revised: 05/14/2014] [Accepted: 05/18/2014] [Indexed: 11/16/2022]
|
24
|
Oh YJ, Jeong KH. Optofluidic SERS chip with plasmonic nanoprobes self-aligned along microfluidic channels. LAB ON A CHIP 2014; 14:865-8. [PMID: 24452813 DOI: 10.1039/c3lc51257f] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
This work reports an optofluidic SERS chip with plasmonic nanoprobes self-aligned along microfluidic channels. Plasmonic nanoprobes with rich electromagnetic hot spots are selectively patterned along PDMS microfluidic channels by using a Scotch tape removal and oxygen plasma treatment, which also provide the permanent bonding between PDMS and a glass substrate. A silver film with an initial thickness of 30 nm after oxygen plasma treatment creates nanotips and nanodots with a maximum SERS performance, which were successfully implanted with microfluidic concentration gradient generators. The novel device enables the label-free and solution-phase SERS detection of small molecules with low Raman activity such as dopamine at micromolar level in flow. This optofluidic SERS chip can be readily expanded for microfluidic networks with diverse functions for advanced optical biochemical assays.
Collapse
Affiliation(s)
- Young-Jae Oh
- Department of Bio and Brain Engineering, KAIST Institute for Optical Science and Technology, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701, Korea.
| | | |
Collapse
|
25
|
Integration of Organic Light Emitting Diodes and Organic Photodetectors for Lab-on-a-Chip Bio-Detection Systems. ELECTRONICS 2014. [DOI: 10.3390/electronics3010043] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
26
|
Gu Y, Valentino G, Mongeau E. Ferrofluid-based reconfigurable optofluidic switches for integrated sensing and digital data storage. APPLIED OPTICS 2014; 53:537-543. [PMID: 24514168 DOI: 10.1364/ao.53.000537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Accepted: 12/10/2013] [Indexed: 06/03/2023]
Abstract
We present a low-cost, reconfigurable, parallel optofluidic switch that exploits the optical and magnetic properties of water-based ferrofluid. Each switch is composed of an integrated waveguide orthogonally crossing a microfluidic channel containing high-index oil and a ferrofluid plug. The switch is turned ON or OFF by movement of the ferrofluid plug. In contrast to conventional integrated switches, ferrofluid plugs act as switching mechanisms that are portable and reconfigurable. Switches are demonstrated in parallel geometries for single and multimode waveguides. Possible applications include optofluidic memory, multiplexed sensing for lab-on-chip, or frequency-encoded laser excitation.
Collapse
|
27
|
Tarn MD, Lopez-Martinez MJ, Pamme N. On-chip processing of particles and cells via multilaminar flow streams. Anal Bioanal Chem 2013; 406:139-61. [DOI: 10.1007/s00216-013-7363-6] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2013] [Revised: 09/09/2013] [Accepted: 09/10/2013] [Indexed: 10/26/2022]
Affiliation(s)
- Mark D Tarn
- Department of Chemistry, The University of Hull, Cottingham Road, Hull, HU6 7RX, UK
| | | | | |
Collapse
|
28
|
Løvhaugen P, Ahluwalia BS, Huser TR, Hellesø OG. Serial Raman spectroscopy of particles trapped on a waveguide. OPTICS EXPRESS 2013; 21:2964-2970. [PMID: 23481754 DOI: 10.1364/oe.21.002964] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We demonstrate that Raman spectroscopy can be used to characterize and identify particles that are trapped and propelled along optical waveguides. To accomplish this, microscopic particles on a waveguide are moved along the waveguide and then individually addressed by a focused laser beam to obtain their characteristic Raman signature within 1 second acquisition time. The spectrum is used to distinguish between glass and polystyrene particles. After the characterization, the particles continue to be propelled along the straight waveguide. Alternatively, a waveguide loop with a gap is also investigated, and in this case particles are held in the gap for characterization before they are released.
Collapse
Affiliation(s)
- Pål Løvhaugen
- Department of Physics and Technology, University of Tromsø, 9037 Tromsø, Norway
| | | | | | | |
Collapse
|
29
|
Cubillas AM, Unterkofler S, Euser TG, Etzold BJM, Jones AC, Sadler PJ, Wasserscheid P, Russell PSJ. Photonic crystal fibres for chemical sensing and photochemistry. Chem Soc Rev 2013; 42:8629-48. [PMID: 23753016 DOI: 10.1039/c3cs60128e] [Citation(s) in RCA: 98] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- Ana M Cubillas
- Max Planck Institute for the Science of Light, Guenther-Scharowsky-Str. 1/Bldg. 24, 91058 Erlangen, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Fujiki M, Yoshida K, Suzuki N, Zhang J, Zhang W, Zhu X. Mirror symmetry breaking and restoration within μm-sized polymer particles in optofluidic media by pumping circularly polarised light. RSC Adv 2013. [DOI: 10.1039/c3ra22709j] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
|
31
|
Yue J, Schouten JC, Nijhuis TA. Integration of Microreactors with Spectroscopic Detection for Online Reaction Monitoring and Catalyst Characterization. Ind Eng Chem Res 2012. [DOI: 10.1021/ie301258j] [Citation(s) in RCA: 98] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Jun Yue
- Laboratory of Chemical Reactor Engineering, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology,
P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Jaap C. Schouten
- Laboratory of Chemical Reactor Engineering, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology,
P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - T. Alexander Nijhuis
- Laboratory of Chemical Reactor Engineering, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology,
P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| |
Collapse
|
32
|
Wu J, Zheng G, Lee LM. Optical imaging techniques in microfluidics and their applications. LAB ON A CHIP 2012; 12:3566-75. [PMID: 22878811 DOI: 10.1039/c2lc40517b] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Microfluidic devices have undergone rapid development in recent years and provide a lab-on-a-chip solution for many biomedical and chemical applications. Optical imaging techniques are essential in microfluidics for observing and extracting information from biological or chemical samples. Traditionally, imaging in microfluidics is achieved by bench-top conventional microscopes or other bulky imaging systems. More recently, many novel compact microscopic techniques have been developed to provide a low-cost and portable solution. In this review, we provide an overview of optical imaging techniques used in microfluidics followed with their applications. We first discuss bulky imaging systems including microscopes and interferometer-based techniques, then we focus on compact imaging systems that can be better integrated with microfluidic devices, including digital in-line holography and scanning-based imaging techniques. The applications in biomedicine or chemistry are also discussed along with the specific imaging techniques.
Collapse
Affiliation(s)
- Jigang Wu
- Biophotonics Laboratory, University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University, Shanghai, 200240, China.
| | | | | |
Collapse
|
33
|
Williams GOS, Chen JSY, Euser TG, Russell PSJ, Jones AC. Photonic crystal fibre as an optofluidic reactor for the measurement of photochemical kinetics with sub-picomole sensitivity. LAB ON A CHIP 2012; 12:3356-3361. [PMID: 22767267 DOI: 10.1039/c2lc40062f] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Photonic crystal fibre constitutes an optofluidic system in which light can be efficiently coupled into a solution-phase sample, contained within the hollow core of the fibre, over long path-lengths. This provides an ideal arrangement for the highly sensitive monitoring of photochemical reactions by absorption spectroscopy. We report here the use of UV/vis spectroscopy to measure the kinetics of the photochemical and thermal cis-trans isomerisation of sub-picomole samples of two azo dyes within the 19-μm diameter core of a photonic crystal fibre, over a path length of 30 cm. Photoisomerisation quantum yields are the first reported for "push-pull" azobenzenes in solution at room temperature; such measurements are challenging because of the fast thermal isomerisation process. Rate constants obtained for thermal isomerisation are in excellent agreement with those established previously in conventional cuvette-based measurements. The high sensitivity afforded by this intra-fibre method enables measurements in solvents in which the dyes are too insoluble to permit conventional cuvette-based measurements. The results presented demonstrate the potential of photonic crystal fibres as optofluidic elements in lab-on-a-chip devices for photochemical applications.
Collapse
Affiliation(s)
- Gareth O S Williams
- EaStCHEM School of Chemistry, King's Buildings, The University of Edinburgh, Edinburgh, EH9 3JJ, United Kingdom
| | | | | | | | | |
Collapse
|
34
|
A selective lead sensor based on a fluorescent molecular probe grafted on a PDMS microfluidic chip. J Photochem Photobiol A Chem 2012. [DOI: 10.1016/j.jphotochem.2012.01.006] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
35
|
Ordeig O, Ortiz P, Muñoz-Berbel X, Demming S, Büttgenbach S, Fernández-Sánchez C, Llobera A. Dual Photonic-Electrochemical Lab on a Chip for Online Simultaneous Absorbance and Amperometric Measurements. Anal Chem 2012; 84:3546-53. [DOI: 10.1021/ac203106x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Olga Ordeig
- Instituto de Microelectrónica
de Barcelona, IMB-CNM (CSIC), Campus UAB,
08193-Bellaterra, Barcelona, Spain
| | - Pedro Ortiz
- Instituto de Microelectrónica
de Barcelona, IMB-CNM (CSIC), Campus UAB,
08193-Bellaterra, Barcelona, Spain
| | - Xavier Muñoz-Berbel
- Instituto de Microelectrónica
de Barcelona, IMB-CNM (CSIC), Campus UAB,
08193-Bellaterra, Barcelona, Spain
| | - Stefanie Demming
- Institut für Mikrotechnik, Technische Universität Braunschweig, Alte Salzdahlumer
Straße 201, 38124 Braunschhweig, Germany
| | - Stephanus Büttgenbach
- Institut für Mikrotechnik, Technische Universität Braunschweig, Alte Salzdahlumer
Straße 201, 38124 Braunschhweig, Germany
| | - César Fernández-Sánchez
- Instituto de Microelectrónica
de Barcelona, IMB-CNM (CSIC), Campus UAB,
08193-Bellaterra, Barcelona, Spain
| | - Andreu Llobera
- Instituto de Microelectrónica
de Barcelona, IMB-CNM (CSIC), Campus UAB,
08193-Bellaterra, Barcelona, Spain
| |
Collapse
|
36
|
Amato L, Gu Y, Bellini N, Eaton SM, Cerullo G, Osellame R. Integrated three-dimensional filter separates nanoscale from microscale elements in a microfluidic chip. LAB ON A CHIP 2012; 12:1135-42. [PMID: 22318474 DOI: 10.1039/c2lc21116e] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We report on the integration of a size-based three-dimensional filter, with micrometre-sized pores, in a commercial microfluidic chip. The filter is fabricated inside an already sealed microfluidic channel using the unique capabilities of two-photon polymerization. This direct-write technique enables integration of the filter by post-processing in a chip that has been fabricated by standard technologies. The filter is located at the intersection of two channels in order to control the amount of flow passing through the filter. Tests with a suspension of 3 μm polystyrene spheres in a Rhodamine 6G solution show that 100% of the spheres are stopped, while the fluorescent molecules are transmitted through the filter. We demonstrate operation up to a period of 25 minutes without any evidence of clogging. Preliminary validation of the device for plasma separation from whole blood is shown. Moreover, the filter can be cleaned and reused by reversing the flow.
Collapse
Affiliation(s)
- Lorenzo Amato
- Istituto di Fotonica e Nanotecnologie-CNR, Dipartimento di Fisica-Politecnico di Milano, Milan, Italy
| | | | | | | | | | | |
Collapse
|
37
|
Horstmann M, Probst K, Fallnich C. Towards an integrated optical single aerosol particle lab. LAB ON A CHIP 2012; 12:295-301. [PMID: 22105700 DOI: 10.1039/c1lc20467j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We present a manipulation and characterization system for single airborne particles which is integrated onto a microscope slide. Trapped particles are manipulated by means of radiation pressure and characterized by cavity enhanced Raman spectroscopy. Optical fibers are used to deliver the trapping laser light as well as to collect the Raman scattered light, allowing for a flexible usage of the device. The system features a sample chamber which is separated from an aerosol-flooded injection chamber by means of a light guiding glass-capillary. The coupling of this device with an aerosol optical tweezers setup to selectively load its trapping sites is demonstrated. Finally, a route towards chip-integrated handling and processing of multiple particles is shown and the first results are presented.
Collapse
Affiliation(s)
- Marcel Horstmann
- Institute of Applied Physics, Westfälische Wilhelms-Universität Münster, Corrensstr. 2, 48149 Münster, Germany.
| | | | | |
Collapse
|
38
|
Fujiki M, Jalilah AJ, Suzuki N, Taguchi M, Zhang W, Abdellatif MM, Nomura K. Chiral optofluidics: gigantic circularly polarized light enhancement of all-trans-poly(9,9-di-n-octylfluorene-2,7-vinylene) during mirror-symmetry-breaking aggregation by optically tuning fluidic media. RSC Adv 2012. [DOI: 10.1039/c2ra20430d] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
39
|
Toru S, Frenea-Robin M, Haddour N, Buret F. Tunable and label-free bacteria alignment using standing surface acoustic waves. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2012:4998-5001. [PMID: 23367050 DOI: 10.1109/embc.2012.6347115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
This paper describes a new technique for focusing bacteria in a microfluidic channel and subsequently controlling their trajectory. Bacteria alignment is obtained using standing surface acoustic waves (SSAW) generated by two interdigitated transducer electrodes (IDTs) patterned on a piezoelectric wafer. The bacteria are focused in the standing wave pressure nodes, separated by half a wavelength, the electrode geometry and applied voltage frequency being chosen accordingly. Interestingly, the position of a pressure node can be modulated by introducing a phase shift between the electrical signals applied to both IDTs. The bacteria, trapped in this node, follow it and can therefore be deflected. This technique works with label-free bacteria in their culture medium and induces low power consumption, which is very interesting for portable devices.
Collapse
Affiliation(s)
- S Toru
- Ecole Centrale Lyon, Ecully, France.
| | | | | | | |
Collapse
|
40
|
Microfluidic Raman Spectroscopy for Bio-chemical Sensing and Analysis. SPRINGER SERIES ON CHEMICAL SENSORS AND BIOSENSORS 2012. [DOI: 10.1007/978-3-642-25498-7_9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
41
|
Ashok PC, Praveen BB, Dholakia K. Near infrared spectroscopic analysis of single malt Scotch whisky on an optofluidic chip. OPTICS EXPRESS 2011; 19:22982-92. [PMID: 22109177 DOI: 10.1364/oe.19.022982] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Standardization and quality monitoring of alcoholic beverages is an important issue in the liquor production industry. Various spectroscopic techniques have proved useful for tackling this problem. An ideal sensing device for alcoholic beverages should be able to detect the quality of alcohol with a small amount of sample at a low acquisition time using a portable and easy to use device. We propose the use of near infra-red spectroscopy on an optofluidic chip for quality monitoring of single malt Scotch whisky. This is chip upon which we have previously realized waveguide confined Raman spectroscopy. Analysis on this alignment-free, portable chip may be performed in only 2 seconds with a sample volume of only 20 µl. Using a partial least square (PLS) calibration, we demonstrate that the alcohol content in the beverage may be predicted to within a 1% prediction error. Principal component analysis (PCA) was employed for successful classification of whiskies based upon their age, type and cask. The prospect of implementing an optofluidic analogue of a conventional fiber based spectroscopic probe allows a rapid analysis of alcoholic beverages with dramatically reduced sample volumes.
Collapse
Affiliation(s)
- Praveen C Ashok
- SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, Fife, Scotland, UK.
| | | | | |
Collapse
|
42
|
Nakano Y, Fujiki M. Circularly Polarized Light Enhancement by Helical Polysilane Aggregates Suspension in Organic Optofluids. Macromolecules 2011. [DOI: 10.1021/ma201665n] [Citation(s) in RCA: 94] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Yoko Nakano
- Graduate School of Materials Science, Nara Institute of Science and Technology (NAIST), 8916-5 Takayama, Ikoma, Nara 630-0192, Japan
| | - Michiya Fujiki
- Graduate School of Materials Science, Nara Institute of Science and Technology (NAIST), 8916-5 Takayama, Ikoma, Nara 630-0192, Japan
| |
Collapse
|
43
|
Hunt HC, Wilkinson JS. Multimode interference devices for focusing in microfluidic channels. OPTICS LETTERS 2011; 36:3067-3069. [PMID: 21847162 DOI: 10.1364/ol.36.003067] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Low-cost, compact, automated optical microsystems for chemical analysis, such as microflow cytometers for identification of individual biological cells, require monolithically integrated microlenses for focusing in microfluidic channels, to enable high-resolution scattering and fluorescence measurements. The multimode interference device (MMI), which makes use of self-imaging in multimode waveguides, is shown to be a simple and effective alternative to the microlens for microflow cytometry. The MMIs have been designed, realized, and integrated with microfluidic channels in a silica-based glass waveguide material system. Focal spot sizes of 2.4 μm for MMIs have been measured at foci as far as 43.7 μm into the microfluidic channel.
Collapse
Affiliation(s)
- Hamish C Hunt
- Optoelectronics Research Centre, University of Southampton, Southampton SO17 1BJ, UK
| | | |
Collapse
|
44
|
Xiong S, Liu AQ, Chin LK, Yang Y. An optofluidic prism tuned by two laminar flows. LAB ON A CHIP 2011; 11:1864-1869. [PMID: 21448472 DOI: 10.1039/c1lc20180h] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
This paper presents a tunable optofluidic prism based on the configuration of two laminar flow streams with different refractive indices in a triangular chamber. The chambers with 70° and 90° apex angles are designed based on simulation results, which provide the optimum working range and avoid recirculating flows in the chambers. In addition, a hydrodynamic model has been developed to predict the tuning of the prisms by the variation in the flow rates. Prisms with different refractive indices are realized using benzyl alcohol and deionized (DI) water as the inner liquids, respectively. The mixture of ethylene glycol and DI water with an effective refractive index matched to that of the microchannel is used as the outer liquid. The apex angle of the prism is tuned from 75° to 135° by adjusting the ratio of the two flow rates. Subsequently, the deviation angle of the output light beam is tuned from -13.5° to 22°. One of the new features of this optofluidic prism is its capability to transform from a symmetric to an asymmetric prism with the assistance of a third flow. Two optical behaviours have been performed using the optofluidic prism. First, parallel light beam scanning is achieved with a constant deviation angle of 10° and a tuning range of 60 μm using the asymmetric prism. The detected output light intensity is increased by 65.7%. Second, light dispersion is experimentally demonstrated using 488-nm and 633-nm laser beams. The two laser beams become distinguishable with a deviation angle difference of 2.5° when the apex angle of the prism reaches 116°.
Collapse
Affiliation(s)
- S Xiong
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore
| | | | | | | |
Collapse
|
45
|
Harz S, Schimmelpfennig M, Tse Sum Bui B, Marchyk N, Haupt K, Feller KH. Fluorescence optical spectrally resolved sensor based on molecularly imprinted polymers and microfluidics. Eng Life Sci 2011. [DOI: 10.1002/elsc.201000222] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
46
|
Lapsley MI, Chiang IK, Zheng YB, Ding X, Mao X, Huang TJ. A single-layer, planar, optofluidic Mach-Zehnder interferometer for label-free detection. LAB ON A CHIP 2011; 11:1795-800. [PMID: 21479332 PMCID: PMC3998765 DOI: 10.1039/c0lc00707b] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
We have developed a planar, optofluidic Mach-Zehnder interferometer for the label-free detection of liquid samples. In contrast to most on-chip interferometers which require complex fabrication, our design was realized via a simple, single-layer soft lithography fabrication process. In addition, a single-wavelength laser source and a silicon photodetector were the only optical equipment used for data collection. The device was calibrated using published data for the refractive index of calcium chloride (CaCl(2)) in solution, and the biosensing capabilities of the device were tested by detecting bovine serum albumin (BSA). Our design enables a refractometer with a low limit of detection (1.24 × 10(-4) refractive index units (RIU)), low variability (1 × 10(-4) RIU), and high sensitivity (927.88 oscillations per RIU). This performance is comparable to state-of-the-art optofluidic refractometers that involve complex fabrication processes and/or expensive, bulky optics. The advantages of our device (i.e. simple fabrication process, straightforward optical equipment, low cost, and high detection sensitivity) make it a promising candidate for future mass-producible, inexpensive, highly sensitive, label-free optical detection systems.
Collapse
Affiliation(s)
- Michael Ian Lapsley
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
| | - I.-Kao Chiang
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
| | - Yue Bing Zheng
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
| | - Xiaoyun Ding
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
| | - Xiaole Mao
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
- Department of Bioengineering, Pennsylvania State University, University Park, PA, 16802, USA
| | - Tony Jun Huang
- Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, PA, 16802, USA
- Department of Bioengineering, Pennsylvania State University, University Park, PA, 16802, USA
| |
Collapse
|
47
|
Ashok PC, Singh GP, Rendall HA, Krauss TF, Dholakia K. Waveguide confined Raman spectroscopy for microfluidic interrogation. LAB ON A CHIP 2011; 11:1262-70. [PMID: 21225053 DOI: 10.1039/c0lc00462f] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
We report the first implementation of the fiber based microfluidic Raman spectroscopic detection scheme, which can be scaled down to micrometre dimensions, allowing it to be combined with other microfluidic functional devices. This novel Raman spectroscopic detection scheme, which we termed as Waveguide Confined Raman Spectroscopy (WCRS), is achieved through embedding fibers on-chip in a geometry that confines the Raman excitation and collection region which ensures maximum Raman signal collection. This results in a microfluidic chip with completely alignment-free Raman spectroscopic detection scheme, which does not give any background from the substrate of the chip. These features allow a WCRS based microfluidic chip to be fabricated in polydimethylsiloxane (PDMS) which is a relatively cheap material but has inherent Raman signatures in fingerprint region. The effects of length, collection angle, and fiber core size on the collection efficiency and fluorescence background of WCRS were investigated. The ability of the device to predict the concentration was studied using urea as a model analyte. A major advantage of WCRS is its scalability that allows it to be combined with many existing microfluidic functional devices. The applicability of WCRS is demonstrated through two microfluidic applications: reaction monitoring in a microreactor and detection of analyte in a microdroplet based microfluidic system. The WCRS approach may lead to wider use of Raman spectroscopy based detection in microfluidics, and the development of portable, alignment-free microfluidic devices.
Collapse
Affiliation(s)
- Praveen C Ashok
- SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, Fife KY16 9SS, UK.
| | | | | | | | | |
Collapse
|
48
|
Schrott W, Nebyla M, Přibyl M, Snita D. Detection of immunoglobulins in a laser induced fluorescence system utilizing polydimethysiloxane microchips with advanced surface and optical properties. BIOMICROFLUIDICS 2011; 5:14101. [PMID: 21359027 PMCID: PMC3045400 DOI: 10.1063/1.3553006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2010] [Accepted: 01/03/2011] [Indexed: 05/11/2023]
Abstract
We developed an automated laser induced fluorescence system utilizing microfluidic chips for detection and quantification of immunoglobulins. Microchips were fabricated from polydimethysiloxane (PDMS) using the so-called "prepolymerization technique." The microchip structure helped minimize the effects of PDMS autofluorescence and light scattering. Furthermore, a thin and uniform PDMS layer forming the top of the microchip enabled proper focusing and collection of the excitation beam and the emitted fluorescence, respectively. The developed system was tested for the detection of mouse immunoglobulins. The capturing antibodies were immobilized on internal microchannel walls in the form of a polyelectrolyte. We clearly show that this immobilization technique, if correctly realized, gives results with high reproducibility. After sample incubation and washing, secondary antibodies labeled by fluorescein isothiocyanate were introduced into microchannels to build a detectable complex. We show that mouse antibodies can be quantified in a wide concentration range, 0.01-100 μg ml(-1). The lower detection limit was below 0.001 μg ml(-1) (6.7 pM). The developed laser induced fluorescence (LIF) apparatus is relatively cheap and easy to construct. The total cost of the developed LIF detector is lower than a typical price of plate readers. If compared to classical ELISA (enzyme linked immunosorbent assay) plate systems, the detection of immunoglobulins or other proteins in the developed PDMS microfluidic device brings other important benefits such as reduced time demands (10 min incubation) and low reagent consumption (less than 1 μl). The cost of the developed PDMS chips is comparable with the price of commercial ELISA plates. The main troubleshooting related to the apparatus development is also discussed in order to help potential constructors.
Collapse
Affiliation(s)
- Walter Schrott
- Department of Chemical Engineering, Institute of Chemical Technology, Prague, Technická 5, 166 28 Praha 6, Czech Republic
| | | | | | | |
Collapse
|
49
|
Gai H, Li Y, Yeung ES. Optical Detection Systems on Microfluidic Chips. MICROFLUIDICS 2011; 304:171-201. [DOI: 10.1007/128_2011_144] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
50
|
Mozharov S, Nordon A, Girkin JM, Littlejohn D. Non-invasive analysis in micro-reactors using Raman spectrometry with a specially designed probe. LAB ON A CHIP 2010; 10:2101-2107. [PMID: 20544108 DOI: 10.1039/c004248j] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
An optical interface has been designed to maximise the sensitivity and spatial resolution required when Raman spectrometry is used to monitor a reaction in a micro-reactor, revealing advantages over a conventional commercial probe. A miniature aspheric lens was shown to be better than microscope objectives to focus the probing laser beam onto the sample. The diameters of the exciting and collection optical fibres were also shown to have a significant influence on sensitivity and the signal-to-background ratio, with 62.5 microm diameter 0.28 numerical aperture (NA) fibres found to be best for analysis of liquids in the 150 microm deep channel in the micro-reactor used. With a spectral measurement time of 2 s, it was shown that the probe could monitor the progress of an esterification reaction in real time and quickly optimise the reagent flow rates. The fast response time revealed features related to short-term pump instabilities and micro-reactor rheology effects that would not have been identified without rapid real-time measurements.
Collapse
Affiliation(s)
- Sergey Mozharov
- WestCHEM, Department of Pure and Applied Chemistry and CPACT, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL, UK
| | | | | | | |
Collapse
|