1
|
Luetkemeyer CM, Neu CP, Calve S. A method for defining tissue injury criteria reveals that ligament deformation thresholds are multimodal. Acta Biomater 2023; 168:252-263. [PMID: 37433358 PMCID: PMC10530537 DOI: 10.1016/j.actbio.2023.07.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 07/05/2023] [Accepted: 07/06/2023] [Indexed: 07/13/2023]
Abstract
Soft tissue injuries (such as ligament, tendon, and meniscus tears) are the result of extracellular matrix damage from excessive tissue stretching. Deformation thresholds for soft tissues, however, remain largely unknown due to a lack of methods that can measure and compare the spatially heterogeneous damage and deformation that occurs in these materials. Here, we propose a full-field method for defining tissue injury criteria: multimodal strain limits for biological tissues analogous to yield criteria that exist for crystalline materials. Specifically, we developed a method for defining strain thresholds for mechanically-driven fibrillar collagen denaturation in soft tissues, using regional multimodal deformation and damage data. We established this new method using the murine medial collateral ligament (MCL) as our model tissue. Our findings revealed that multiple modes of deformation contribute to collagen denaturation in the murine MCL, contrary to the common assumption that collagen damage is driven only by strain in the direction of fibers. Remarkably, hydrostatic strain (computed here with an assumption of plane strain) was the best predictor of mechanically-driven collagen denaturation in ligament tissue, suggesting crosslink-mediated stress transfer plays a role in molecular damage accumulation. This work demonstrates that collagen denaturation can be driven by multiple modes of deformation and provides a method for defining deformation thresholds, or injury criteria, from spatially heterogeneous data. STATEMENT OF SIGNIFICANCE: Understanding the mechanics of soft tissue injuries is crucial for the development of new technology for injury detection, prevention, and treatment. Yet, tissue-level deformation thresholds for injury are unknown, due to a lack of methods that combine full-field measurements of multimodal deformation and damage in mechanically loaded soft tissues. Here, we propose a method for defining tissue injury criteria: multimodal strain thresholds for biological tissues. Our findings reveal that multiple modes of deformation contribute to collagen denaturation, contrary to the common assumption that collagen damage is driven by strain in the fiber direction alone. The method will inform the development of new mechanics-based diagnostic imaging, improve computational modeling of injury, and be employed to study the role of tissue composition in injury susceptibility.
Collapse
Affiliation(s)
- Callan M Luetkemeyer
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, United States; Department of Mechanical Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL, United States.
| | - Corey P Neu
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, United States; Biomedical Engineering Program, University of Colorado Boulder, Boulder, CO, United States; BioFrontiers Institute, University of Colorado Boulder, Boulder, CO, United States
| | - Sarah Calve
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, United States; Biomedical Engineering Program, University of Colorado Boulder, Boulder, CO, United States; BioFrontiers Institute, University of Colorado Boulder, Boulder, CO, United States; Materials Science and Engineering Program, University of Colorado Boulder, Boulder, CO, United States
| |
Collapse
|
2
|
Bloom ET, Lin LM, Locke RC, Giordani A, Krassan E, Peloquin JM, Silbernagel KG, Parreno J, Santare MH, Killian ML, Elliott DM. Overload in a Rat In Vivo Model of Synergist Ablation Induces Tendon Multiscale Structural and Functional Degeneration. J Biomech Eng 2023; 145:081003. [PMID: 37184932 PMCID: PMC10782872 DOI: 10.1115/1.4062523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 05/02/2023] [Accepted: 05/04/2023] [Indexed: 05/16/2023]
Abstract
Tendon degeneration is typically described as an overuse injury with little distinction made between magnitude of load (overload) and number of cycles (overuse). Further, in vivo, animal models of tendon degeneration are mostly overuse models, where tendon damage is caused by a high number of load cycles. As a result, there is a lack of knowledge of how isolated overload leads to degeneration in tendons. A surgical model of synergist ablation (SynAb) overloads the target tendon, plantaris, by ablating its synergist tendon, Achilles. The objective of this study was to evaluate the structural and functional changes that occur following overload of plantaris tendon in a rat SynAb model. Tendon cross-sectional area (CSA) and shape changes were evaluated by longitudinal MR imaging up to 8 weeks postsurgery. Tissue-scale structural changes were evaluated by semiquantified histology and second harmonic generation microscopy. Fibril level changes were evaluated with serial block face scanning electron microscopy (SBF-SEM). Functional changes were evaluated using tension tests at the tissue and microscale using a custom testing system allowing both video and microscopy imaging. At 8 weeks, overloaded plantaris tendons exhibited degenerative changes including increases in CSA, cell density, collagen damage area fraction (DAF), and fibril diameter, and decreases in collagen alignment, modulus, and yield stress. To interpret the differences between overload and overuse in tendon, we introduce a new framework for tendon remodeling and degeneration that differentiates between the inputs of overload and overuse. In summary, isolated overload induces multiscale degenerative structural and functional changes in plantaris tendon.
Collapse
Affiliation(s)
- Ellen T Bloom
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716
| | - Lily M Lin
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716
| | - Ryan C Locke
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA 19104; Translational Musculoskeletal Research Center, CMCVAMC, Philadelphia, PA 19104
| | - Alyssa Giordani
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716
| | - Erin Krassan
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716
| | - John M Peloquin
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716
| | | | - Justin Parreno
- Department of Biological Sciences, University of Delaware, Newark, DE 19716
| | - Michael H Santare
- Department of Mechanical Engineering, University of Delaware, Newark, DE 19716
| | - Megan L Killian
- Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI 48104
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, DE 19716
| |
Collapse
|
3
|
Luetkemeyer CM, Neu CP, Calve S. A method for defining tissue injury criteria reveals ligament deformation thresholds are multimodal. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.01.31.526318. [PMID: 36778317 PMCID: PMC9915655 DOI: 10.1101/2023.01.31.526318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Soft tissue injuries (such as ligament, tendon, and meniscus tears) are the result of extracellular matrix damage from excessive tissue stretching. Deformation thresholds for soft tissues, however, remain largely unknown due to a lack of methods that can measure and compare the spatially heterogeneous damage and deformation that occurs in these materials. Here, we propose a method for defining tissue injury criteria : multimodal strain limits for biological tissues analogous to yield criteria that exist for crystalline materials. Specifically, we developed a method for defining injury criteria for mechanically-driven fibrillar collagen denaturation in soft tissues, using regional multimodal deformation and damage data. We established this new method using the murine medial collateral ligament (MCL) as our model tissue. Our findings revealed that multiple modes of deformation contribute to collagen denaturation in the murine MCL, contrary to the common assumption that collagen damage is driven by strain in the fiber direction alone. Remarkably, our results indicated that hydrostatic strain, or volumetric expansion, may be the best predictor of mechanically-driven collagen denaturation in ligament tissue, suggesting crosslink-mediated stress transfer plays a role in molecular damage accumulation. This work demonstrates that collagen denaturation can be driven by multiple modes of deformation and provides a method for defining deformation thresholds, or injury criteria, from spatially heterogeneous data.
Collapse
|
4
|
Application of "Magnetic Anchors" to Align Collagen Fibres for Axonal Guidance. Gels 2021; 7:gels7040154. [PMID: 34698174 PMCID: PMC8544430 DOI: 10.3390/gels7040154] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 09/24/2021] [Accepted: 09/24/2021] [Indexed: 11/21/2022] Open
Abstract
The use of neural scaffolds with a highly defined microarchitecture, fabricated with standard techniques such as electrospinning and microfluidic spinning, requires surgery for their application to the site of injury. To circumvent the risk associated with aciurgy, new strategies for treatment are sought. This has led to an increase in the quantity of research into injectable hydrogels in recent years. However, little research has been conducted into controlling the building blocks within these injectable hydrogels to produce similar scaffolds with a highly defined microarchitecture. “Magnetic particle string” and biomimetic amphiphile self-assembly are some of the methods currently available to achieve this purpose. Here, we developed a “magnetic anchor” method to improve the orientation of collagen fibres within injectable 3D scaffolds. This procedure uses GMNP (gold magnetic nanoparticle) “anchors” capped with CMPs (collagen mimetic peptides) that “chain” them to collagen fibres. Through the application of a magnetic field during the gelling process, these collagen fibres are aligned accordingly. It was shown in this study that the application of CMP functionalised GMNPs in a magnetic field significantly improves the alignment of the collagen fibres, which, in turn, improves the orientation of PC12 neurites. The growth of these neurite extensions, which were shown to be significantly longer, was also improved. The PC12 cells grown in collagen scaffolds fabricated using the “magnetic anchor” method shows comparable cellular viability to that of the untreated collagen scaffolds. This capability of remote control of the alignment of fibres within injectable collagen scaffolds opens up new strategic avenues in the research for treating debilitating neural tissue pathologies.
Collapse
|
5
|
Xydias D, Ziakas G, Psilodimitrakopoulos S, Lemonis A, Bagli E, Fotsis T, Gravanis A, Tzeranis DS, Stratakis E. Three-dimensional characterization of collagen remodeling in cell-seeded collagen scaffolds via polarization second harmonic generation. BIOMEDICAL OPTICS EXPRESS 2021; 12:1136-1153. [PMID: 33680563 PMCID: PMC7901316 DOI: 10.1364/boe.411501] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 11/24/2020] [Accepted: 12/01/2020] [Indexed: 05/08/2023]
Abstract
In this study, we use non-linear imaging microscopy to characterize the structural properties of porous collagen-GAG scaffolds (CGS) seeded with human umbilical vein endothelial cells (HUVECs), as well as human mesenchymal stem cells (hMSCs), a co-culture previously reported to form vessel-like structures inside CGS. The evolution of the resulting tissue construct was monitored over 10 days via simultaneous two- and three-photon excited fluorescence microscopy. Time-lapsed 2- and 3-photon excited fluorescence imaging was utilized to monitor the temporal evolution of the vascular-like structures up to 100 µm inside the scaffold up to 10 days post-seeding. 3D polarization-dependent second harmonic generation (PSHG) was utilized to monitor collagen-based scaffold remodeling and determine collagen fibril orientation up to 200 µm inside the scaffold. We demonstrate that polarization-dependent second harmonic generation can provide a novel way to quantify the reorganization of the collagen architecture in CGS simultaneously with key biomechanical interactions between seeded cells and CGS that regulate the formation of vessel-like structures inside 3D tissue constructs. A comparison between samples at different days in vitro revealed that gradually, the scaffolds developed an orthogonal net-like architecture, previously found in real skin.
Collapse
Affiliation(s)
- Dionysios Xydias
- Institute of Electronic Structure and Laser, Foundation for Research and Technology-Hellas, Greece
- Department of Materials Science and Technology, School of Sciences and Engineering, University of Crete, Greece
| | - Georgios Ziakas
- Department of Materials Science and Technology, School of Sciences and Engineering, University of Crete, Greece
| | | | - Andreas Lemonis
- Institute of Electronic Structure and Laser, Foundation for Research and Technology-Hellas, Greece
| | - Eleni Bagli
- Department of Biomedical Research, Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, Ioannina, Greece
| | - Theodore Fotsis
- Department of Biomedical Research, Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, Ioannina, Greece
| | - Achille Gravanis
- Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, Greece
- Department of Pharmacology, School of Medicine, University of Crete, Greece
| | - Dimitrios S. Tzeranis
- Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, Greece
- Department of Mechanical and Manufacturing Engineering, University of Cyprus, Cyprus, Greece
| | - Emmanuel Stratakis
- Institute of Electronic Structure and Laser, Foundation for Research and Technology-Hellas, Greece
- Department of Physics, School of Sciences and Engineering, University of Crete, Greece
| |
Collapse
|
6
|
Tehrani KF, Pendleton EG, Southern WM, Call JA, Mortensen LJ. Spatial frequency metrics for analysis of microscopic images of musculoskeletal tissues. Connect Tissue Res 2021; 62:4-14. [PMID: 33028134 PMCID: PMC7718369 DOI: 10.1080/03008207.2020.1828381] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Purpose: Imaging-based metrics for analysis of biological tissues are powerful tools that can extract information such as shape, size, periodicity, and many other features to assess the requested qualities of a tissue. Muscular and osseous tissues consist of periodic structures that are directly related to their function, and so analysis of these patterns likely reflects tissue health and regeneration.Methods: A method for assessment of periodic structures is by analyzing them in the spatial frequency domain using the Fourier transform. In this paper, we present two filters which we developed in the spatial frequency domain for the purpose of analyzing musculoskeletal structures. These filters provide information about 1) the angular orientation of the tissues and 2) their periodicity. We explore periodic structural patterns in the mitochondrial network of skeletal muscles that are reflective of muscle metabolism and myogenesis; and patterns of collagen fibers in the bone that are reflective of the organization and health of bone extracellular matrix.Results: We present an analysis of mouse skeletal muscle in healthy and injured muscles. We used a transgenic mouse that ubiquitously expresses fluorescent protein in their mitochondria and performed 2-photon microscopy to image the structures. To acquire the collagen structure of the bone we used non-linear SHG microscopy of mouse flat bone. We analyze and compare juvenile versus adult mice, which have different structural patterns.Conclusions: Our results indicate that these metrics can quantify musculoskeletal tissues during development and regeneration.
Collapse
Affiliation(s)
- Kayvan Forouhesh Tehrani
- Regenerative Bioscience Center, Rhodes Center for ADS,
University of Georgia, Athens, GA 30602, USA
| | - Emily G. Pendleton
- Regenerative Bioscience Center, Rhodes Center for ADS,
University of Georgia, Athens, GA 30602, USA
| | - W. Michael Southern
- Department of Kinesiology, University of Georgia, Athens,
GA 30602, USA,Currently with Department of Biochemistry, Molecular
Biology, and Biophysics, University of Minnesota, Minneapolis, MN 55455, USA
| | - Jarrod A. Call
- Regenerative Bioscience Center, Rhodes Center for ADS,
University of Georgia, Athens, GA 30602, USA,Department of Kinesiology, University of Georgia, Athens,
GA 30602, USA
| | - Luke J. Mortensen
- Regenerative Bioscience Center, Rhodes Center for ADS,
University of Georgia, Athens, GA 30602, USA,School of Chemical, Materials and Biomedical Engineering,
University of Georgia, Athens, GA 30602, USA,
| |
Collapse
|
7
|
Maier F, Siri S, Santos S, Chen L, Feng B, Pierce DM. The heterogeneous morphology of networked collagen in distal colon and rectum of mice quantified via nonlinear microscopy. J Mech Behav Biomed Mater 2020; 113:104116. [PMID: 33049619 DOI: 10.1016/j.jmbbm.2020.104116] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 09/14/2020] [Accepted: 09/24/2020] [Indexed: 02/06/2023]
Abstract
Visceral pain from the distal colon and rectum (colorectum) is a major complaint of patients with irritable bowel syndrome. Mechanotransduction of colorectal distension/stretch appears to play a critical role in visceral nociception, and further understanding requires improved knowledge of the micromechanical environments at different sub-layers of the colorectum. In this study, we conducted nonlinear imaging via second harmonic generation to quantify the thickness of each distinct through-thickness layer of the colorectum, as well as the principal orientations, corresponding dispersions in orientations, and the distributions of diameters of collagen fibers within each of these layers. From C57BL/6 mice of both sexes (8-16 weeks of age, 25-35 g), we dissected the distal 30 mm of the large bowel including the colorectum, divided these into three even segments, and harvested specimens (~8 × 8 mm2) from each segment. We stretched the specimens either by colorectal distension to 20 mmHg (reference) or 80 mmHg (deformed) or by biaxial stretch to 10 mN (reference) or 80 mN (deformed), and fixed them with 4% paraformaldehyde. We then conducted SHG imaging through the wall thickness and analyzed post-hoc using custom-built software to quantify the orientations of collagen fibers in all distinct layers. We also quantified the thickness of each layer of the colorectum, and the corresponding distributions of collagen density and diameters of fibers. We found collagen concentrated in the submucosal layer. The average diameter of collagen fibers was greatest in the submucosal layer, followed by the serosal and muscular layers. Collagen fibers aligned with muscle fibers in the two muscular layers, whereas their orientation varied greatly with location in the serosal layer. In colonic segments, thick collagen fibers in the submucosa presented two major orientations aligned approximately ±30° to the axial direction, and form a patterned network. Our results indicate the submucosa is likely the principal passive load-bearing structure of the colorectum. In addition, afferent endings in those collagen-rich regions present likely candidates of colorectal nociceptors to encode noxious distension/stretch.
Collapse
Affiliation(s)
- Franz Maier
- Department of Mechanical Engineering, University of Connecticut, CT, 06269, USA
| | - Saeed Siri
- Department of Biomedical Engineering, University of Connecticut, CT, 06269, USA
| | - Stephany Santos
- Department of Biomedical Engineering, University of Connecticut, CT, 06269, USA
| | - Longtu Chen
- Department of Biomedical Engineering, University of Connecticut, CT, 06269, USA
| | - Bin Feng
- Department of Biomedical Engineering, University of Connecticut, CT, 06269, USA.
| | - David M Pierce
- Department of Mechanical Engineering, University of Connecticut, CT, 06269, USA; Department of Biomedical Engineering, University of Connecticut, CT, 06269, USA.
| |
Collapse
|
8
|
Pendleton EG, Tehrani KF, Barrow RP, Mortensen LJ. Second harmonic generation characterization of collagen in whole bone. BIOMEDICAL OPTICS EXPRESS 2020; 11:4379-4396. [PMID: 32923050 PMCID: PMC7449751 DOI: 10.1364/boe.391866] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 06/10/2020] [Accepted: 06/16/2020] [Indexed: 05/24/2023]
Abstract
Bone is a unique biological composite material made up of a highly structured collagen mesh matrix and mineral deposits. Although mineral provides stiffness, collagen's secondary organization provides a critical role in bone elasticity. Here, we performed polarimetric analysis of bone collagen fibers using second harmonic generation (SHG) imaging to evaluate lamella sheets and collagen fiber integrity in intact cranial bone. Our polarimetric data was fitted to a model accounting for diattenuation, polarization cross-talk, and birefringence. We compared our data to the fitted model and found no significant difference between our polarimetric observation and the representation of these scattering properties up to 70 µm deep. We also observed a loss of resolution as we imaged up to 70 µm deep into bone but a conservation of polarimetric response. Polarimetric SHG allows for the discrimination of collagen lamellar sheet structures in intact bone. Our work could allow for label-free identification of disease states and monitor the efficacy of therapies for bone disorders.
Collapse
Affiliation(s)
- Emily G. Pendleton
- Regenerative Bioscience Center, Rhodes Center for ADS, University of Georgia, Athens, GA 30602, USA
| | - Kayvan F. Tehrani
- Regenerative Bioscience Center, Rhodes Center for ADS, University of Georgia, Athens, GA 30602, USA
| | - Ruth P. Barrow
- Regenerative Bioscience Center, Rhodes Center for ADS, University of Georgia, Athens, GA 30602, USA
| | - Luke J. Mortensen
- Regenerative Bioscience Center, Rhodes Center for ADS, University of Georgia, Athens, GA 30602, USA
- School of Chemical, Materials and Biomedical Engineering, University of Georgia, Athens, GA 30602, USA
| |
Collapse
|
9
|
Shkarin R, Shkarina S, Weinhardt V, Surmenev RA, Surmeneva MA, Shkarin A, Baumbach T, Mikut R. GPU-accelerated ray-casting for 3D fiber orientation analysis. PLoS One 2020; 15:e0236420. [PMID: 32726324 PMCID: PMC7390437 DOI: 10.1371/journal.pone.0236420] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Accepted: 07/06/2020] [Indexed: 12/01/2022] Open
Abstract
Orientation analysis of fibers is widely applied in the fields of medical, material and life sciences. The orientation information allows predicting properties and behavior of materials to validate and guide a fabrication process of materials with controlled fiber orientation. Meanwhile, development of detector systems for high-resolution non-invasive 3D imaging techniques led to a significant increase in the amount of generated data per a sample up to dozens of gigabytes. Though plenty of 3D orientation estimation algorithms were developed in recent years, neither of them can process large datasets in a reasonable amount of time. This fact complicates the further analysis and makes impossible fast feedback to adjust fabrication parameters. In this work, we present a new method for quantifying the 3D orientation of fibers. The GPU implementation of the proposed method surpasses another popular method for 3D orientation analysis regarding accuracy and speed. The validation of both methods was performed on a synthetic dataset with varying parameters of fibers. Moreover, the proposed method was applied to perform orientation analysis of scaffolds with different fibrous micro-architecture studied with the synchrotron μCT imaging setup. Each acquired dataset of size 600x600x450 voxels was analyzed in less 2 minutes using standard PC equipped with a single GPU.
Collapse
Affiliation(s)
- Roman Shkarin
- Laboratory for Applications of Synchrotron Radiation, Karlsruhe Institute of Technology, Karlsruhe, Germany
- Institute for Automation and Applied Computer Science, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Svetlana Shkarina
- Physical Materials Science and Composite Materials Centre, Research School of Chemistry & Applied Biomedical Sciences, National Research Tomsk Polytechnic University, Tomsk, Russia
- Institute for Photon Science and Synchrotron Radiation, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
| | - Venera Weinhardt
- Laboratory for Applications of Synchrotron Radiation, Karlsruhe Institute of Technology, Karlsruhe, Germany
- Institute for Photon Science and Synchrotron Radiation, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
- Centre for Organismal Studies, COS, Heidelberg University, Heidelberg, Germany
| | - Roman A. Surmenev
- Physical Materials Science and Composite Materials Centre, Research School of Chemistry & Applied Biomedical Sciences, National Research Tomsk Polytechnic University, Tomsk, Russia
| | - Maria A. Surmeneva
- Physical Materials Science and Composite Materials Centre, Research School of Chemistry & Applied Biomedical Sciences, National Research Tomsk Polytechnic University, Tomsk, Russia
| | - Andrei Shkarin
- Laboratory for Applications of Synchrotron Radiation, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Tilo Baumbach
- Laboratory for Applications of Synchrotron Radiation, Karlsruhe Institute of Technology, Karlsruhe, Germany
- Institute for Photon Science and Synchrotron Radiation, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
| | - Ralf Mikut
- Institute for Automation and Applied Computer Science, Karlsruhe Institute of Technology, Karlsruhe, Germany
| |
Collapse
|
10
|
Lee AH, Elliott DM. Comparative multi-scale hierarchical structure of the tail, plantaris, and Achilles tendons in the rat. J Anat 2019; 234:252-262. [PMID: 30484871 PMCID: PMC6326909 DOI: 10.1111/joa.12913] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2018] [Indexed: 12/19/2022] Open
Abstract
Rodent tendons are widely used to study human pathologies such as tendinopathy and repair, and to address fundamental physiological questions about development, growth, and remodeling. However, how the gross morphology and multi-scale hierarchical structure of rat tendons, such as the tail, plantaris, and Achilles tendons, compare with that of human tendons are unknown. In addition, there remains disagreement about terminology and definitions. Specifically, the definitions of fascicle and fiber are often dependent on diameter sizes, not their characteristic features, and these definitions impair the ability to compare hierarchical structure across species, where the sizes of the fiber and fascicle may change with animal size and tendon function. Thus, the objective of the study was to select a single species that is commonly used for tendon research (rat) and tendons with varying mechanical functions (tail, plantaris, Achilles) to evaluate the hierarchical structure at multiple length scales using histology, SEM, and confocal imaging. With the exception of the specialized rat tail tendon, we confirmed that in rat tendons there are no fascicles and the fiber is the largest subunit. In addition, we provided a structurally based definition of a fiber as a bundle of collagen fibrils that is surrounded by elongated cells, and this definition was supported by both histologically processed and unprocessed samples. In all rat tendons studied, the fiber diameters were consistently between 10 and 50 μm, and this diameter range appears to be conserved across larger species. Specific recommendations were made highlighting the strengths and limitations of each rat tendon as a research model. Understanding the hierarchical structure of tendon can advance the design and interpretation of experiments and development of tissue-engineered constructs.
Collapse
Affiliation(s)
- Andrea H. Lee
- Department of Biomedical EngineeringUniversity of DelawareNewarkUSA
| | - Dawn M. Elliott
- Department of Biomedical EngineeringUniversity of DelawareNewarkUSA
| |
Collapse
|
11
|
Gluck MJ, Vijayaraghavan S, Sinclair EB, Ashraf A, Hausman MR, Cagle PJ. Detecting structural and inflammatory response after in vivo stretch injury in the rat median nerve via second harmonic generation. J Neurosci Methods 2018; 303:68-80. [PMID: 29454014 DOI: 10.1016/j.jneumeth.2018.02.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2017] [Revised: 02/07/2018] [Accepted: 02/11/2018] [Indexed: 10/18/2022]
Abstract
BACKGROUND Second Harmonic Generation (SHG) microscopy is a promising method for visualizing the collagenous structure of peripheral nerves. Assessing collagen continuity and damage after a stretch injury provides inferential insight into the level of axonal damage present. NEW METHODS This study utilizes SHG microscopy after a calibrated in vivo stretch injury of rat median nerves to evaluate collagen continuity at several time points throughout the recovery process. Endoneurial collagen was qualitatively assessed in nerves that were subjected to low strain (LS) and high strain (HS) injuries using SHG microscopy, conventional histology, and immunohistochemistry. RESULTS Following an in vivo stretch injury, both LS and HS damaged nerves exhibit signs of structural collagen damage in comparison with sham control nerves (SC). Furthermore, LS nerves exhibit signs of full regeneration while HS nerves exhibited signs of only partial regeneration with lasting damage and intra-neural scar formation. COMPARISON WITH EXISTING METHODS SHG observations of structural changes and inflammatory response due to stretch injury were validated upon comparison with conventional histological methods CONCLUSIONS: We propose that SHG microscopy can be utilized to visualize significant structural artifacts in sectioned median nerves following in vivo stretch injury. Based on the findings in this study, we believe that the in vivo application of SHG microscopy should be further investigated as a means for real-time, intra-operative, quantitative assessment of nerve damage.
Collapse
Affiliation(s)
- Matthew J Gluck
- Leni & Peter W. May Department of Orthopaedic Surgery, Icahn School of Medicine at Mount Sinai, United States.
| | - Surabhi Vijayaraghavan
- Leni & Peter W. May Department of Orthopaedic Surgery, Icahn School of Medicine at Mount Sinai, United States
| | - Elaine B Sinclair
- Leni & Peter W. May Department of Orthopaedic Surgery, Icahn School of Medicine at Mount Sinai, United States
| | - Asad Ashraf
- Leni & Peter W. May Department of Orthopaedic Surgery, Icahn School of Medicine at Mount Sinai, United States
| | - Michael R Hausman
- Leni & Peter W. May Department of Orthopaedic Surgery, Icahn School of Medicine at Mount Sinai, United States
| | - Paul J Cagle
- Leni & Peter W. May Department of Orthopaedic Surgery, Icahn School of Medicine at Mount Sinai, United States
| |
Collapse
|
12
|
Herod TW, Veres SP. Development of overuse tendinopathy: A new descriptive model for the initiation of tendon damage during cyclic loading. J Orthop Res 2018; 36:467-476. [PMID: 28598009 DOI: 10.1002/jor.23629] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Accepted: 06/05/2017] [Indexed: 02/04/2023]
Abstract
Tendinopathic tissue has long been characterized by changes to collagen microstructure. However, initial tendon damage from excessive mechanical loading-a hallmark of tendinopathy development-could occur at the nanoscale level of collagen fibrils. Indeed, it is on this scale that tenocytes interact directly with tendon matrix, and excessive collagen fibril damage not visible at the microscale could trigger a degenerative cascade. In this study, we explored whether initiation of tendon damage during cyclic loading occurs via a longitudinal compression-induced buckling mechanism of collagen fibrils leading to nanoscale kinkband development. Two groups of tendons were cyclically loaded to equivalent peak stresses. In each loading cycle, tendons in one group were unloaded to the zero displacement mark, while those in the other group were unloaded to a nominal level of tension, minimizing the potential for fibril buckling. Tendons that were unloaded to the zero displacement mark ruptured significantly sooner during cyclic loading (1,446 ± 737 vs. 4,069 ± 1,129 cycles), indicating that significant fatigue damage is accrued in the low stress, toe region of the load-deformation response. Ultrastructural analysis using scanning electron microscopy of tendons stopped after 1,000 cycles showed that maintaining a nominal tension slowed the accumulation of kinkbands, supporting a longitudinal compression-induced buckling mechanism as the basis for kinkband development. Based on our results, we present a new descriptive model for the initiation of tendon damage during cyclic loading. The so-called Compression of Unrecovered Elongation or CUE Model may provide useful insight into the development of tendinopathy. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:467-476, 2018.
Collapse
Affiliation(s)
- Tyler W Herod
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Samuel P Veres
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada.,Division of Engineering, Saint Mary's University, 923 Robie Street, Halifax, Nova Scotia Canada B3H 3C3
| |
Collapse
|
13
|
Hase E, Sato K, Yonekura D, Minamikawa T, Takahashi M, Yasui T. Evaluation of the histological and mechanical features of tendon healing in a rabbit model with the use of second-harmonic-generation imaging and tensile testing. Bone Joint Res 2016; 5:577-585. [PMID: 27881441 PMCID: PMC5131088 DOI: 10.1302/2046-3758.511.bjr-2016-0162.r1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Accepted: 10/06/2016] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES This study aimed to evaluate the histological and mechanical features of tendon healing in a rabbit model with second-harmonic-generation (SHG) imaging and tensile testing. MATERIALS AND METHODS A total of eight male Japanese white rabbits were used for this study. The flexor digitorum tendons in their right leg were sharply transected, and then were repaired by intratendinous stitching. At four weeks post-operatively, the rabbits were killed and the flexor digitorum tendons in both right and left legs were excised and used as specimens for tendon healing (n = 8) and control (n = 8), respectively. Each specimen was examined by SHG imaging, followed by tensile testing, and the results of the two testing modalities were assessed for correlation. RESULTS While the SHG light intensity of the healing tendon samples was significantly lower than that of the uninjured tendon samples, 2D Fourier transform SHG images showed a clear difference in collagen fibre structure between the uninjured and the healing samples, and among the healing samples. The mean intensity of the SHG image showed a moderate correlation (R2 = 0.37) with Young's modulus obtained from the tensile testing. CONCLUSION Our results indicate that SHG microscopy may be a potential indicator of tendon healing.Cite this article: E. Hase, K. Sato, D. Yonekura, T. Minamikawa, M. Takahashi, T. Yasui. Evaluation of the histological and mechanical features of tendon healing in a rabbit model with the use of second-harmonic-generation imaging and tensile testing. Bone Joint Res 2016;5:577-585. DOI: 10.1302/2046-3758.511.BJR-2016-0162.R1.
Collapse
Affiliation(s)
- E Hase
- Graduate School of Advanced Technology and Science, The Tokushima University, Tokushima 770-8506, Japan
| | - K Sato
- Graduate School of Science and Technology, The Tokushima University, Tokushima 770-8506, Japan
| | - D Yonekura
- Graduate School of Science and Technology, The Tokushima University, Tokushima 770-8506, Japan
| | - T Minamikawa
- Graduate School of Science and Technology, The Tokushima University, Tokushima 770-8506, Japan
| | - M Takahashi
- Department of Orthopaedic Surgery, Tokushima Prefectural Central Hospital, Tokushima, 770-8539, Japan
| | - T Yasui
- Graduate School of Science and Technology, The Tokushima University, Tokushima 770-8506, Japan
| |
Collapse
|
14
|
Herod TW, Chambers NC, Veres SP. Collagen fibrils in functionally distinct tendons have differing structural responses to tendon rupture and fatigue loading. Acta Biomater 2016; 42:296-307. [PMID: 27321189 DOI: 10.1016/j.actbio.2016.06.017] [Citation(s) in RCA: 62] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Revised: 06/03/2016] [Accepted: 06/10/2016] [Indexed: 12/24/2022]
Abstract
UNLABELLED In this study we investigate relationships between the nanoscale structure of collagen fibrils and the macroscale functional response of collagenous tissues. To do so, we study two functionally distinct classes of tendons, positional tendons and energy storing tendons, using a bovine forelimb model. Molecular-level assessment using differential scanning calorimetry (DSC), functional crosslink assessment using hydrothermal isometric tension (HIT) analysis, and ultrastructural assessment using scanning electron microscopy (SEM) were used to study undamaged, ruptured, and cyclically loaded samples from the two tendon types. HIT indicated differences in both crosslink type and crosslink density, with flexor tendons having more thermally stable crosslinks than the extensor tendons (higher TFmax of >90 vs. 75.1±2.7°C), and greater total crosslink density than the extensor tendons (higher t1/2 of 11.5±1.9 vs. 3.5±1.0h after NaBH4 treatment). Despite having a lower crosslink density than flexor tendons, extensor tendons were significantly stronger (37.6±8.1 vs. 23.1±7.7MPa) and tougher (14.3±3.6 vs. 6.8±3.4MJ/m(3)). SEM showed that collagen fibrils in the tougher, stronger extensor tendons were able to undergo remarkable levels of plastic deformation in the form of discrete plasticity, while those in the flexor tendons were not able to plastically deform. When cyclically loaded, collagen fibrils in extensor tendons accumulated fatigue damage rapidly in the form of kink bands, while those in flexor tendons did not accumulate significant fatigue damage. The results demonstrate that collagen fibrils in functionally distinct tendons respond differently to mechanical loading, and suggests that fibrillar collagens may be subject to a strength vs. fatigue resistance tradeoff. STATEMENT OF SIGNIFICANCE Collagen fibrils-nanoscale biological cables-are the fundamental load-bearing elements of all structural human tissues. While all collagen fibrils share common features, such as being composed of a precise quarter-staggered polymeric arrangement of triple-helical collagen molecules, their structure can vary significantly between tissue types, and even between different anatomical structures of the same tissue type. To understand normal function, homeostasis, and disease of collagenous tissues requires detailed knowledge of collagen fibril structure-function. Using anatomically proximate but structurally distinct tendons, we show that collagen fibrils in functionally distinct tendons have differing susceptibilities to damage under both tensile overload and cyclic fatigue loading. Our results suggest that the structure of collagen fibrils may lead to a strength versus fatigue resistance tradeoff, where high strength is gained at the expense of fatigue resistance, and vice versa.
Collapse
Affiliation(s)
- Tyler W Herod
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Neil C Chambers
- Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada
| | - Samuel P Veres
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada; Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada.
| |
Collapse
|
15
|
Bell R, Boniello M, Gendron N, Flatow E, Andarawis-Puri N. Delayed exercise promotes remodeling in sub-rupture fatigue damaged tendons. J Orthop Res 2015; 33:919-25. [PMID: 25732052 PMCID: PMC4417076 DOI: 10.1002/jor.22856] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2014] [Accepted: 02/08/2015] [Indexed: 02/04/2023]
Abstract
Tendinopathy is a common musculoskeletal injury whose treatment is limited by ineffective therapeutic interventions. Previously we have shown that tendons ineffectively repair early sub-rupture fatigue damage. In contrast, physiological exercise has been shown to promote remodeling of healthy tendons but its utility as a therapeutic to promote repair of fatigue damaged tendons remains unknown. Therefore, the objective of this study was to assess the utility of exercise initiated 1 and 14 days after onset of fatigue damage to promote structural repair in fatigue damaged tendons. We hypothesized that exercise initiated 14 days after fatigue loading would promote remodeling as indicated by a decrease in area of collagen matrix damage, increased procollagen I and decorin, while decreasing proteins indicative of tendinopathy. Rats engaged in 6-week exercise for 30 min/day or 60 min/day starting 1 or 14 days after fatigue loading. Initiating exercise 1-day after onset of fatigue injury led to exacerbation of matrix damage, particularly at the tendon insertion. Initiating exercise 14 days after onset of fatigue injury led to remodeling of damaged regions in the midsubstance and collagen synthesis at the insertion. Physiological exercise applied after the initial biological response to injury has dampened can potentially promote remodeling of damaged tendons.
Collapse
Affiliation(s)
- R. Bell
- Leni and Peter W. May Department of Orthopaedics; Icahn School of Medicine at Mount Sinai; One Gustave L. Levy Place Box 1188 New York New York
| | - M.R. Boniello
- Leni and Peter W. May Department of Orthopaedics; Icahn School of Medicine at Mount Sinai; One Gustave L. Levy Place Box 1188 New York New York
| | - N.R. Gendron
- Leni and Peter W. May Department of Orthopaedics; Icahn School of Medicine at Mount Sinai; One Gustave L. Levy Place Box 1188 New York New York
| | - E.L. Flatow
- Leni and Peter W. May Department of Orthopaedics; Icahn School of Medicine at Mount Sinai; One Gustave L. Levy Place Box 1188 New York New York
| | - N. Andarawis-Puri
- Leni and Peter W. May Department of Orthopaedics; Icahn School of Medicine at Mount Sinai; One Gustave L. Levy Place Box 1188 New York New York
| |
Collapse
|
16
|
Freedman BR, Zuskov A, Sarver JJ, Buckley MR, Soslowsky LJ. Evaluating changes in tendon crimp with fatigue loading as an ex vivo structural assessment of tendon damage. J Orthop Res 2015; 33:904-10. [PMID: 25773654 PMCID: PMC4416993 DOI: 10.1002/jor.22875] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Accepted: 02/13/2015] [Indexed: 02/04/2023]
Abstract
The complex structure of tendons relates to their mechanical properties. Previous research has associated the waviness of collagen fibers (crimp) during quasi-static tensile loading to tensile mechanical properties, but less is known about the role of fatigue loading on crimp properties. In this study (IACUC approved), mouse patellar tendons were fatigue loaded while an integrated plane polariscope simultaneously assessed crimp properties. We demonstrate a novel structural mechanism whereby tendon crimp amplitude and frequency are altered with fatigue loading. In particular, fatigue loading increased the crimp amplitude across the tendon width and length, and these structural alterations were shown to be both region and load dependent. The change in crimp amplitude was strongly correlated to mechanical tissue laxity (defined as the ratio of displacement and gauge length relative to the first cycle of fatigue loading assessed at constant load throughout testing), at all loads and regions evaluated. Together, this study highlights the role of fatigue loading on tendon crimp properties as a function of load applied and region evaluated, and offers an additional structural mechanism for mechanical alterations that may lead to ultimate tendon failure.
Collapse
Affiliation(s)
- Benjamin R. Freedman
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Joseph J. Sarver
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA,Department of Biomedical Engineering, Drexel University, Philadelphia, PA, USA
| | - Mark R. Buckley
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA,Department of Biomedical Engineering, University of Rochester, Rochester, NY, USA
| | - Louis J. Soslowsky
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
17
|
WU JP, WALTON M, WANG A, ANDERSON P, WANG T, KIRK T, ZHENG M. The development of confocal arthroscopy as optical histology for rotator cuff tendinopathy. J Microsc 2015; 259:269-75. [DOI: 10.1111/jmi.12260] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2014] [Accepted: 03/26/2015] [Indexed: 01/26/2023]
Affiliation(s)
- J.-P. WU
- Department of Mechanical Engineering; Curtin University; Perth Australia
| | - M. WALTON
- Wrightington Hospital; Upper Limb Unit; Wigan UK
| | - A. WANG
- School of Surgery; University of Western Australia; Perth Australia
| | | | - T. WANG
- School of Surgery; University of Western Australia; Perth Australia
| | - T.B. KIRK
- Department of Mechanical Engineering; Curtin University; Perth Australia
| | - M.H. ZHENG
- School of Surgery; University of Western Australia; Perth Australia
| |
Collapse
|
18
|
Collagen Fibrils in Skin Orient in the Direction of Applied Uniaxial Load in Proportion to Stress while Exhibiting Differential Strains around Hair Follicles. MATERIALS 2015; 8:1841-1857. [PMID: 28788035 PMCID: PMC5507025 DOI: 10.3390/ma8041841] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/04/2015] [Revised: 04/09/2015] [Accepted: 04/14/2015] [Indexed: 11/17/2022]
Abstract
We determined inhomogeneity of strains around discontinuities as well as changes in orientation of collagen fibrils under applied load in skin. Second Harmonic Generation (SHG) images of collagen fibrils were obtained at different strain magnitudes. Changes in collagen orientation were analyzed using Fast Fourier Transforms (FFT) while strain inhomogeneity was determined at different distances from hair follicles using Digital Image Correlation (DIC). A parameter, defined as the Collagen Orientation Index (COI), is introduced that accounts for the increasingly ellipsoidal nature of the FFT amplitude images upon loading. We show that the COI demonstrates two distinct mechanical regimes, one at low strains (0%, 2.5%, 5% strain) in which randomly oriented collagen fibrils align in the direction of applied deformation. In the second regime, beginning at 5% strain, collagen fibrils elongate in response to applied deformation. Furthermore, the COI is also found to be linearly correlated with the applied stress indicating that collagen fibrils orient to take the applied load. DIC results indicated that major principal strains were found to increase with increased load at all locations. In contrast, minimum principal strain was dependent on distance from hair follicles. These findings are significant because global and local changes in collagen deformations are expected to be changed by disease, and could affect stem cell populations surrounding hair follicles, including mesenchymal stem cells within the outer root sheath.
Collapse
|
19
|
Wen BL, Brewer MA, Nadiarnykh O, Hocker J, Singh V, Mackie TR, Campagnola PJ. Texture analysis applied to second harmonic generation image data for ovarian cancer classification. JOURNAL OF BIOMEDICAL OPTICS 2014; 19:096007. [PMID: 26296156 PMCID: PMC4161736 DOI: 10.1117/1.jbo.19.9.096007] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2014] [Revised: 08/14/2014] [Accepted: 08/15/2014] [Indexed: 05/21/2023]
Abstract
Remodeling of the extracellular matrix has been implicated in ovarian cancer. To quantitate the remodeling, we implement a form of texture analysis to delineate the collagen fibrillar morphology observed in second harmonic generation microscopy images of human normal and high grade malignant ovarian tissues. In the learning stage, a dictionary of “textons”—frequently occurring texture features that are identified by measuring the image response to a filter bank of various shapes, sizes, and orientations—is created. By calculating a representative model based on the texton distribution for each tissue type using a training set of respective second harmonic generation images, we then perform classification between images of normal and high grade malignant ovarian tissues. By optimizing the number of textons and nearest neighbors, we achieved classification accuracy up to 97% based on the area under receiver operating characteristic curves (true positives versus false positives). The local analysis algorithm is a more general method to probe rapidly changing fibrillar morphologies than global analyses such as FFT. It is also more versatile than other texture approaches as the filter bank can be highly tailored to specific applications (e.g., different disease states) by creating customized libraries based on common image features.
Collapse
Affiliation(s)
- Bruce L. Wen
- University of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin 53706, United States
- Morgridge Institute for Research, Madison, Wisconsin 53715, United States
| | - Molly A. Brewer
- University of Connecticut Health Center, Department of Obstetrics and Gynecology, Farmington, Connecticut 06030, United States
| | - Oleg Nadiarnykh
- VU University Amsterdam, VU Medical Center, 1007 MB Amsterdam, Netherlands
| | - James Hocker
- University of Wisconsin-Madison, Department of Biomedical Engineering, Madison, Wisconsin 53706, United States
| | - Vikas Singh
- University of Wisconsin-Madison, Department of Biostatistics and Medical Informatics, Madison, Wisconsin 53706, United States
| | - Thomas R. Mackie
- University of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin 53706, United States
- Morgridge Institute for Research, Madison, Wisconsin 53715, United States
| | - Paul J. Campagnola
- University of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin 53706, United States
- University of Wisconsin-Madison, Department of Biomedical Engineering, Madison, Wisconsin 53706, United States
- Address all correspondence to: Paul J. Campagnola, E-mail:
| |
Collapse
|
20
|
Tilbury K, Hocker J, Wen BL, Sandbo N, Singh V, Campagnola PJ. Second harmonic generation microscopy analysis of extracellular matrix changes in human idiopathic pulmonary fibrosis. JOURNAL OF BIOMEDICAL OPTICS 2014; 19:086014. [PMID: 25134793 PMCID: PMC4137064 DOI: 10.1117/1.jbo.19.8.086014] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2014] [Revised: 07/16/2014] [Accepted: 07/17/2014] [Indexed: 05/21/2023]
Abstract
Patients with idiopathic fibrosis (IPF) have poor long-term survival as there are limited diagnostic/prognostic tools or successful therapies. Remodeling of the extracellular matrix (ECM) has been implicated in IPF progression; however, the structural consequences on the collagen architecture have not received considerable attention. Here, we demonstrate that second harmonic generation (SHG) and multiphoton fluorescence microscopy can quantitatively differentiate normal and IPF human tissues. For SHG analysis, we developed a classifier based on wavelet transforms, principle component analysis, and a K-nearest-neighbor algorithm to classify the specific alterations of the collagen structure observed in IPF tissues. The resulting ROC curves obtained by varying the numbers of principal components and nearest neighbors yielded accuracies of >95%. In contrast, simpler metrics based on SHG intensity and collagen coverage in the image provided little or no discrimination. We also characterized the change in the elastin/collagen balance by simultaneously measuring the elastin autofluorescence and SHG intensities and found that the IPF tissues were less elastic relative to collagen. This is consistent with known mechanical consequences of the disease. Understanding ECM remodeling in IPF via nonlinear optical microscopy may enhance our ability to differentiate patients with rapid and slow progression and, thus, provide better prognostic information.
Collapse
Affiliation(s)
- Karissa Tilbury
- University of Wisconsin–Madison, Department of Biomedical Engineering, Madison, Wisconsin 53706, United States
| | - James Hocker
- University of Wisconsin–Madison, Department of Biomedical Engineering, Madison, Wisconsin 53706, United States
| | - Bruce L. Wen
- University of Wisconsin–Madison, Medical Physics Department, Madison, Wisconsin 53706, United States
- Morgridge Institute for Research, Madison, Wisconsin 53715, United States
| | - Nathan Sandbo
- University of Wisconsin, School of Medicine and Public Health Madison, Division of Allergy, Pulmonary, and Critical Care Medicine, Madison, Wisconsin 53706, United States
| | - Vikas Singh
- University of Wisconsin–Madison, Department of Biostatistics and Medical Informatics, Madison, Wisconsin 53706, United States
| | - Paul J. Campagnola
- University of Wisconsin–Madison, Department of Biomedical Engineering, Madison, Wisconsin 53706, United States
- University of Wisconsin–Madison, Medical Physics Department, Madison, Wisconsin 53706, United States
- Address all correspondence to: Paul J. Campagnola, E-mail:
| |
Collapse
|
21
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HR. Effect of fatigue loading on structure and functional behaviour of fascicles from energy-storing tendons. Acta Biomater 2014; 10:3217-24. [PMID: 24747261 DOI: 10.1016/j.actbio.2014.04.008] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Revised: 03/07/2014] [Accepted: 04/08/2014] [Indexed: 11/26/2022]
Abstract
Tendons can broadly be categorized according to their function: those that act purely to position the limb and those that have an additional function as energy stores. Energy-storing tendons undergo many cycles of large deformations during locomotion, and so must be able to extend and recoil efficiently, rapidly and repeatedly. Our previous work has shown rotation in response to applied strain in fascicles from energy-storing tendons, indicating the presence of helical substructures which may provide greater elasticity and recovery. In the current study, we assessed how preconditioning and fatigue loading affect the ability of fascicles from the energy-storing equine superficial digital flexor tendon to extend and recoil. We hypothesized that preconditioned samples would exhibit changes in microstructural strain response, but would retain their ability to recover. We further hypothesized that fatigue loading would result in sample damage, causing further alterations in extension mechanisms and a significant reduction in sample recovery. The results broadly support these hypotheses: preconditioned samples showed some alterations in microstructural strain response, but were able to recover following the removal of load. However, fatigue loaded samples showed visual evidence of damage and exhibited further alterations in extension mechanisms, characterized by decreased rotation in response to applied strain. This was accompanied by increased hysteresis and decreased recovery. These results suggest that fatigue loading results in a compromised helix substructure, reducing the ability of energy-storing tendons to recoil. A decreased ability to recoil may lead to an impaired response to further loading, potentially increasing the likelihood of injury.
Collapse
|
22
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HRC. Fascicles from energy-storing tendons show an age-specific response to cyclic fatigue loading. J R Soc Interface 2014; 11:20131058. [PMID: 24402919 DOI: 10.1098/rsif.2013.1058] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Some tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), act as energy stores, stretching and recoiling to increase efficiency during locomotion. Our previous observations of rotation in response to applied strain in SDFT fascicles suggest a helical structure, which may provide energy-storing tendons with a greater ability to extend and recoil efficiently. Despite this specialization, energy-storing tendons are prone to age-related tendinopathy. The aim of this study was to assess the effect of cyclic fatigue loading (FL) on the microstructural strain response of SDFT fascicles from young and old horses. The data demonstrate two independent age-related mechanisms of fatigue failure; in young horses, FL caused low levels of matrix damage and decreased rotation. This suggests that loading causes alterations to the helix substructure, which may reduce their ability to recoil and recover. By contrast, fascicles from old horses, in which the helix is already compromised, showed greater evidence of matrix damage and suffer increased fibre sliding after FL, which may partially explain the age-related increase in tendinopathy. Elucidation of helix structure and the precise alterations occurring owing to both ageing and FL will help to develop appropriate preventative and repair strategies for tendinopathy.
Collapse
Affiliation(s)
- Chavaunne T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, , Mile End Road, London E1 4NS, UK
| | | | | | | | | |
Collapse
|
23
|
Veres SP, Harrison JM, Lee JM. Cross-link stabilization does not affect the response of collagen molecules, fibrils, or tendons to tensile overload. J Orthop Res 2013; 31:1907-13. [PMID: 24038530 DOI: 10.1002/jor.22460] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2013] [Accepted: 07/15/2013] [Indexed: 02/04/2023]
Abstract
We investigated whether immature allysine-derived cross-links provide mechanically labile linkages by exploring the effects of immature cross-link stabilization at three levels of collagen hierarchy: damaged fibril morphology, whole tendon mechanics, and molecular stability. Tendons from the tails of young adult steers were either treated with sodium borohydride (NaBH₄) to stabilize labile cross-links, exposed only to the buffer used during stabilization treatment, or maintained as untreated controls. One-half of each tendon was then subjected to five cycles of subrupture overload. Morphologic changes to collagen fibrils resulting from overload were investigated using scanning electron microscopy, and changes in the hydrothermal stability of collagen molecules were assessed using hydrothermal isometric tension testing. NaBH4 cross-link stabilization did not affect the response of tendon collagen to tensile overload at any of the three levels of hierarchy studied. Cross-link stabilization did not prevent the characteristic overload-induced mode of fibril damage that we term discrete plasticity. Similarly, stabilization did not alter the mechanical response of whole tendons to overload, and did not prevent an overload-induced thermal destabilization of collagen molecules. Our results indicate that hydrothermally labile cross-links may not be as mechanically labile as was previously thought.
Collapse
Affiliation(s)
- Samuel P Veres
- Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada, B3H 3C3
| | | | | |
Collapse
|
24
|
Ros SJ, Andarawis-Puri N, Flatow EL. Tendon extracellular matrix damage detection and quantification using automated edge detection analysis. J Biomech 2013; 46:2844-7. [PMID: 24112781 DOI: 10.1016/j.jbiomech.2013.09.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2013] [Revised: 08/16/2013] [Accepted: 09/04/2013] [Indexed: 11/17/2022]
Abstract
The accumulation of sub-rupture tendon fatigue damage in the extracellular matrix, particularly of type I collagen fibrils, is thought to contribute to the development of tendinopathy, a chronic and degenerative pathology of tendons. Quantitative assessment of collagen fibril alignment is paramount to understanding the importance of matrix injury to cellular function and remodeling capabilities. This study presents a novel application of edge detection analysis to calculate local collagen fibril orientation in tendon. This technique incorporates damage segmentation and stratification by severity which will allow future analysis of the direct effect of matrix damage severity on the cellular and molecular response.
Collapse
Affiliation(s)
- Stephen J Ros
- Leni and Peter W. May Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, 5 East 98th Street, 9th Floor, New York, NY 10029, United States
| | | | | |
Collapse
|
25
|
Bueno JM, Palacios R, Chessey MK, Ginis H. Analysis of spatial lamellar distribution from adaptive-optics second harmonic generation corneal images. BIOMEDICAL OPTICS EXPRESS 2013; 4:1006-13. [PMID: 23847727 PMCID: PMC3704083 DOI: 10.1364/boe.4.001006] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Revised: 04/24/2013] [Accepted: 04/24/2013] [Indexed: 05/20/2023]
Abstract
The spatial organization of stromal collagen of ex-vivo corneas has been quantified in adaptive-optics second harmonic generation (SHG) images by means of an optimized Fourier transform (FT) based analysis. At a particular depth location, adjacent lamellae often present similar orientations and run parallel to the corneal surface. However this pattern might be combined with interweaved collagen bundles leading to crosshatched structures with different orientations. The procedure here reported provides us with both principal and crosshatched angles. This is also able to automatically distinguish a random distribution from a cross-shaped one, since it uses the ratio of the axes lengths of the best-fitted ellipse of the FT data as an auxiliary parameter. The technique has successfully been applied to SHG images of healthy corneas (both stroma and Bowman's layer) of different species and to corneas undergoing cross-linking treatment.
Collapse
|
26
|
Robertson C, Ikemura K, Krasieva TB, George SC. Multiscale analysis of collagen microstructure with generalized image correlation spectroscopy and the detection of tissue prestress. Biomaterials 2013; 34:6127-32. [PMID: 23642533 DOI: 10.1016/j.biomaterials.2013.04.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2013] [Accepted: 04/10/2013] [Indexed: 12/13/2022]
Abstract
Prestress in tissue is currently detected through destructive methods which obviate both in vivo and longitudinal assessment. We hypothesized that prestress could be detected and quantified by analyzing the microstructure of the extracellular matrix at different spatial scales using non-invasive and non-destructive optical imaging. A simple model of tissue prestress was created using fibroblast-mediated contraction of collagen gels around a central mandrel. Using a quantitative, multiscale, image processing technique, termed generalized image correlation spectroscopy (GICS) of second harmonic images, collagen fiber number and alignment at three different length scales characteristic of the collagen fibril, collagen fiber, and cell were analyzed. GICS fiber alignment (σ(maj/min)) was significantly different across load state, level of prestress, and length scale. The largest fiber ratio, and thus highest alignment, was seen in prestressed, externally loaded gels at a length scale equivalent to the size of the fibroblast cells. Alignment at both fiber and cell scale correlated with prestress in this model. We conclude that GICS of second harmonic images of collagen can predict prestress, and that microstructural organization at the collagen fiber and cell scale are the primary determinants of prestress in cellularized collagen gels.
Collapse
Affiliation(s)
- Claire Robertson
- Department of Biomedical Engineering, University of California, Irvine, CA, USA
| | | | | | | |
Collapse
|
27
|
Karamichos D, Zareian R, Guo X, Hutcheon AE, Ruberti JW, Zieske JD. Novel in Vitro Model for Keratoconus Disease. J Funct Biomater 2012; 3:760-775. [PMID: 23888249 PMCID: PMC3719435 DOI: 10.3390/jfb3040760] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Keratoconus is a disease where the cornea becomes cone-like due to structural thinning and ultimately leads to compromised corneal integrity and loss of vision. Currently, the therapeutic options are corrective lenses for early stages and surgery for advanced cases with no in vitro model available. In this study, we used human corneal fibroblasts (HCFs) and compared them to human Keratoconus fibroblasts (HKCs) cultured in a 3-dimensional (3D) model, in order to compare the expression and secretion of specific extracellular matrix (ECM) components. For four weeks, the cells were stimulated with a stable Vitamin C (VitC) derivative ± TGF-β1 or TGF-β3 (T1 and T3, respectively). After four weeks, HKCs stimulated with T1 and T3 were significantly thicker compared with Control (VitC only); however, HCF constructs were significantly thicker than HKCs under all conditions. Both cell types secreted copious amounts of type I and V collagens in their assembled, aligned collagen fibrils, which increased in the degree of alignment upon T3 stimulation. In contrast, only HKCs expressed high levels of corneal scarring markers, such as type III collagen, which was dramatically reduced with T3. HKCs expressed α-smooth muscle actin (SMA) under all conditions in contrast to HCFs, where T3 minimized SMA expression. Fast Fourier transform (FFT) data indicated that HKCs were more aligned when compared to HCFs, independent of treatments; however, HKC’s ECM showed the least degree of rotation. HKCs also secreted the most aligned type I collagen under T3 treatment, when compared to any condition and cell type. Overall, our model for Keratoconus disease studies is the first 3D in vitro tissue engineered model that can mimic the Keratoconus disease in vivo and may be a breakthrough in efforts to understand the progression of this disease.
Collapse
Affiliation(s)
- Dimitrios Karamichos
- Schepens Eye Research Institute/Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA 02114, USA; (X.G.); (A.H.); (J.Z.)
- Author to whom correspondence should be addressed; ; Tel.: +1-617-912-0280; Fax: +1-617-912-0107
| | - Ramin Zareian
- Mechanical & Industrial Engineering, Northeastern University, Boston, MA 02115, USA; (R.Z.); (J.W.R.)
| | - Xiaoqing Guo
- Schepens Eye Research Institute/Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA 02114, USA; (X.G.); (A.H.); (J.Z.)
| | - Audrey E.K. Hutcheon
- Schepens Eye Research Institute/Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA 02114, USA; (X.G.); (A.H.); (J.Z.)
| | - Jeffrey W. Ruberti
- Mechanical & Industrial Engineering, Northeastern University, Boston, MA 02115, USA; (R.Z.); (J.W.R.)
| | - James D. Zieske
- Schepens Eye Research Institute/Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA 02114, USA; (X.G.); (A.H.); (J.Z.)
| |
Collapse
|
28
|
Abraham T, Kayra D, McManus B, Scott A. Quantitative assessment of forward and backward second harmonic three dimensional images of collagen Type I matrix remodeling in a stimulated cellular environment. J Struct Biol 2012; 180:17-25. [PMID: 22609365 PMCID: PMC4858383 DOI: 10.1016/j.jsb.2012.05.004] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2011] [Revised: 04/30/2012] [Accepted: 05/03/2012] [Indexed: 10/28/2022]
Abstract
The structural remodeling of collagens is important in several biological processes including wound healing, tendon repair and adaptation, fibrosis and morphogenesis. Multiphoton microscopy is efficient in the induction of highly specific second harmonic generation (SHG) signal from non-centrosymmetric macromolecules such as fibrillar collagens. Although the detectors in the reflection geometry have been normally employed for capturing the backward scattered SHG considering the wide range of engineered thick tissue applications, there are still questions about the generated 3D collagen structures because of the directional pattern of SHG signals. The present study dealt with an in vitro collagen-fibroblast raft or bioartificial tendon model where the stimulation of fibroblast cells induced lateral orientation of collagen Type I fibers. The SHG signals originating from 3D collagen matrix were captured simultaneously in both forward and backward scattering directions. Our structural analysis indicates that collagen fibers formed in such in vitro model systems are predominantly of uniform sizes and are aligned preferentially in the lateral direction. The criss-cross arrangements of laterally oriented fibers are evident in the initial stages of contraction but eventually those laterally oriented collagen fibers are found to be aligned in parallel to each other as well as to the fibroblasts after an extended period of contraction. Our comprehensive quantitative assessment of simultaneously captured forward and backward 3D SHG image datasets, which includes the SHG signal decay, fiber diameter, cell dimensions, colocalization profiles, the 3D voxel volumes and Fourier analysis, indicates strong correlation of structural features identified in forward and backward directions.
Collapse
Affiliation(s)
- Thomas Abraham
- UBC James Hogg Research Centre, Institute for Heart+Lung Health, Vancouver, Canada.
| | | | | | | |
Collapse
|
29
|
Sinclair EB, Andarawis-Puri N, Ros SJ, Laudier DM, Jepsen KJ, Hausman MR. Relating applied strain to the type and severity of structural damage in the rat median nerve using second harmonic generation microscopy. Muscle Nerve 2012; 46:899-907. [DOI: 10.1002/mus.23443] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/30/2012] [Indexed: 11/07/2022]
|
30
|
Affiliation(s)
- Pramod B. Voleti
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania 19104-6081;
| | - Mark R. Buckley
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania 19104-6081;
| | - Louis J. Soslowsky
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania 19104-6081;
| |
Collapse
|
31
|
Sereysky JB, Andarawis-Puri N, Jepsen KJ, Flatow EL. Structural and mechanical effects of in vivo fatigue damage induction on murine tendon. J Orthop Res 2012; 30:965-72. [PMID: 22072573 PMCID: PMC3755359 DOI: 10.1002/jor.22012] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2010] [Accepted: 10/20/2011] [Indexed: 02/04/2023]
Abstract
The purpose of this study was to develop and validate an in vivo mouse model of tendon fatigue and use this model to investigate and quantify the physical manifestations of fatigue damage in mouse tendon. Patellar tendons of C57BL/6J mice were fatigue loaded at 2 Hz to three endpoints (4 N peak force per cycle for 1 h, 6 N for 1 h, and 4 N for 2 h), during which hysteresis, tangent stiffness, and peak strain of each cycle were measured. Damage accumulation was then quantified using in situ histology, and each tendon was loaded monotonically to failure. Histological damage increased significantly in all three groups (≥2-fold), and monotonic stiffness decreased significantly in the 6 N, 1 h and 4 N, 2-h groups (~25%), suggesting that damage initially manifests as changes to the collagen structure of the tendon and subsequently as changes to the function. For the fatigue loading protocols used in this study, none of the evaluated real-time parameters from fatigue loading correlated with damage area fraction measured structural damage or monotonic stiffness, suggesting that they are not suited to serve as proxies for damage accumulation. In future studies, this model will be used to compare the biological response of mouse tendon to fatigue damage across genetic strains.
Collapse
Affiliation(s)
- Jedd B Sereysky
- Leni and Peter W. May Department of Orthopaedics, Mount Sinai School of Medicine, New York, New York 10029, USA
| | | | | | | |
Collapse
|
32
|
Gaida JE, Bagge J, Purdam C, Cook J, Alfredson H, Forsgren S. Evidence of the TNF-a System in the Human Achilles Tendon: Expression of TNF-a and TNF Receptor at both Protein and mRNA Levels in the Tenocytes. Cells Tissues Organs 2012; 196:339-52. [DOI: 10.1159/000335475] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/28/2011] [Indexed: 12/22/2022] Open
|
33
|
Cox G. Biological applications of second harmonic imaging. Biophys Rev 2011; 3:131. [PMID: 28510062 DOI: 10.1007/s12551-011-0052-9] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2011] [Accepted: 07/04/2011] [Indexed: 11/26/2022] Open
Abstract
Second Harmonic Generation (SHG) microscopy dates back to 1974, but effective biological use of the technique has a history of barely 10 years. It is now widely used to image collagen in many different applications, and is becoming useful for imaging myosin and some polysaccharides. A separate line on research has focussed on SHG dyes, which can provide high-speed indication of membrane potential and are now in use in neurobiology. This review looks at the progress to date in these different fields.
Collapse
Affiliation(s)
- Guy Cox
- Australian Centre for Microscopy and Microanalysis, University of Sydney, NSW, 2006, Australia.
| |
Collapse
|
34
|
Goulam Houssen Y, Gusachenko I, Schanne-Klein MC, Allain JM. Monitoring micrometer-scale collagen organization in rat-tail tendon upon mechanical strain using second harmonic microscopy. J Biomech 2011; 44:2047-52. [PMID: 21636086 DOI: 10.1016/j.jbiomech.2011.05.009] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2011] [Revised: 05/04/2011] [Accepted: 05/06/2011] [Indexed: 11/30/2022]
Abstract
We continuously monitored the microstructure of a rat-tail tendon during stretch/relaxation cycles. To that purpose, we implemented a new biomechanical device that combined SHG imaging and mechanical testing modalities. This multi-scale experimental device enabled simultaneous visualization of the collagen crimp morphology at the micrometer scale and measurement of macroscopic strain-stress response. We gradually increased the ultimate strain of the cycles and showed that preconditioning mostly occurs in the first stretching. This is accompanied by an increase of the crimp period in the SHG image. Our results indicate that preconditioning is due to a sliding of microstructures at the scale of a few fibrils and smaller, that changes the resting length of the fascicle. This sliding can reverse on long time scales. These results provide a proof of concept that continuous SHG imaging performed simultaneously with mechanical assay allows analysis of the relationship between macroscopic response and microscopic structure of tissues.
Collapse
Affiliation(s)
- Y Goulam Houssen
- Ecole Polytechnique, Laboratory for Optics and Biosciences, 91128 Palaiseau, France
| | | | | | | |
Collapse
|
35
|
Andarawis-Puri N, Flatow EL. Tendon fatigue in response to mechanical loading. JOURNAL OF MUSCULOSKELETAL & NEURONAL INTERACTIONS 2011; 11:106-114. [PMID: 21625047 PMCID: PMC4408766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Tendinopathies are commonly attributable to accumulation of sub-rupture fatigue damage from repetitive use. Data is limited to late stage disease from patients undergoing surgery, motivating development of animal models, such as ones utilizing treadmill running or repetitive reaching, to investigate the progression of tendinopathies. We developed an in vivo model using the rat patellar tendon that allows control of the loading directly applied to the tendon. This manuscript discusses the response of tendons to fatigue loading and applications of our model. Briefly, the fatigue life of the tendon was used to define low, moderate and high levels of fatigue loading. Morphological assessment showed a progression from mild kinks to fiber disruption, for low to high level fatigue loading. Collagen expression, 1 and 3 days post loading, showed more modest changes for low and moderate than high level fatigue loading. Protein and mRNA expression of Ineterleukin-1β and MMP-13 were upregulated for moderate but not low level fatigue loading. Moderate level (7200 cycles) and 100 cycles of fatigue loading resulted in a catabolic and anabolic molecular profile respectively, at both 1 and 7 days post loading. Results suggest unique mechanisms for different levels of fatigue loading that are distinct from laceration.
Collapse
Affiliation(s)
- N Andarawis-Puri
- Leni and Peter W. May Department of Orthopaedics, Mount Sinai School of Medicine, New York, NY 10029, USA
| | | |
Collapse
|
36
|
Sereysky JB, Andarawis-Puri N, Ros SJ, Jepsen KJ, Flatow EL. Automated image analysis method for quantifying damage accumulation in tendon. J Biomech 2010; 43:2641-4. [PMID: 20627302 DOI: 10.1016/j.jbiomech.2010.04.043] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2010] [Revised: 04/12/2010] [Accepted: 04/30/2010] [Indexed: 10/19/2022]
Abstract
Tendon pathology is frequently sub-clinical prior to frank rupture, denoting the need for non-destructive methods of assessing disease presence and progression. Despite the lack of clinical presentation, previous studies have observed that distinct changes to the tendon microstructure are present, and that such qualitative changes have a dose-response relationship with the level of damage accumulated. These initial findings suggest that there is value in investigating the physical nature of damage within tendon, not only to better understand the pathological process, but also to gain insight into reparative processes and develop treatments. However, a necessary first step towards carrying out these avenues of research is to develop diagnostic tools for quantitatively assessing the level of damage present. In this study, we established a dose-response relationship between a quantitative measure of structural damage and the level of global damage induced. Furthermore, we developed and validated an automated technique for quantifying matrix disorganization (damage), which correlates and co-localizes strongly with manual quantification. In combination, these findings allow us to measure the amount of damage accumulation of a region of tendon on a clinical scale, rapidly and accurately.
Collapse
Affiliation(s)
- Jedd B Sereysky
- Leni & Peter W. May Department of Orthopaedics, Mount Sinai School of Medicine, 9th Floor, New York, NY 10029, USA
| | | | | | | | | |
Collapse
|