1
|
Merken L, Schelles M, Ceyssens F, Kraft M, Janssen P. Thin flexible arrays for long-term multi-electrode recordings in macaque primary visual cortex. J Neural Eng 2022; 19. [PMID: 36215972 DOI: 10.1088/1741-2552/ac98e2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Accepted: 10/10/2022] [Indexed: 01/11/2023]
Abstract
Objective.Basic, translational and clinical neuroscience are increasingly focusing on large-scale invasive recordings of neuronal activity. However, in large animals such as nonhuman primates and humans-in which the larger brain size with sulci and gyri imposes additional challenges compared to rodents, there is a huge unmet need to record from hundreds of neurons simultaneously anywhere in the brain for long periods of time. Here, we tested the electrical and mechanical properties of thin, flexible multi-electrode arrays (MEAs) inserted into the primary visual cortex of two macaque monkeys, and assessed their magnetic resonance imaging (MRI) compatibility and their capacity to record extracellular activity over a period of 1 year.Approach.To allow insertion of the floating arrays into the visual cortex, the 20 by 100µm2shafts were temporarily strengthened by means of a resorbable poly(lactic-co-glycolic acid) coating.Main results. After manual insertion of the arrays, theex vivoandin vivoMRI compatibility of the arrays proved to be excellent. We recorded clear single-unit activity from up to 50% of the electrodes, and multi-unit activity (MUA) on 60%-100% of the electrodes, which allowed detailed measurements of the receptive fields and the orientation selectivity of the neurons. Even 1 year after insertion, we obtained significant MUA responses on 70%-100% of the electrodes, while the receptive fields remained remarkably stable over the entire recording period.Significance.Thus, the thin and flexible MEAs we tested offer several crucial advantages compared to existing arrays, most notably in terms of brain tissue compliance, scalability, and brain coverage. Future brain-machine interface applications in humans may strongly benefit from this new generation of chronically implanted MEAs.
Collapse
Affiliation(s)
- Lara Merken
- Laboratory for Neuro- and Psychophysiology, KU Leuven, Leuven 3000, Belgium.,Leuven Brain Institute, KU Leuven, Leuven 3000, Belgium
| | - Maarten Schelles
- Micro- and Nanosystems (MNS), Electrical Engineering Department (ESAT), KU Leuven, Leuven 3000, Belgium.,ReVision Implant NV, Haasrode 3053, Belgium
| | | | - Michael Kraft
- Micro- and Nanosystems (MNS), Electrical Engineering Department (ESAT), KU Leuven, Leuven 3000, Belgium.,Leuven Institute for Micro- and Nanotechnology (LIMNI), Leuven 3000, Belgium
| | - Peter Janssen
- Laboratory for Neuro- and Psychophysiology, KU Leuven, Leuven 3000, Belgium.,Leuven Brain Institute, KU Leuven, Leuven 3000, Belgium
| |
Collapse
|
2
|
Luo J, Xue N, Chen J. A Review: Research Progress of Neural Probes for Brain Research and Brain-Computer Interface. BIOSENSORS 2022; 12:bios12121167. [PMID: 36551135 PMCID: PMC9775442 DOI: 10.3390/bios12121167] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 12/07/2022] [Accepted: 12/13/2022] [Indexed: 06/01/2023]
Abstract
Neural probes, as an invasive physiological tool at the mesoscopic scale, can decipher the code of brain connections and communications from the cellular or even molecular level, and realize information fusion between the human body and external machines. In addition to traditional electrodes, two new types of neural probes have been developed in recent years: optoprobes based on optogenetics and magnetrodes that record neural magnetic signals. In this review, we give a comprehensive overview of these three kinds of neural probes. We firstly discuss the development of microelectrodes and strategies for their flexibility, which is mainly represented by the selection of flexible substrates and new electrode materials. Subsequently, the concept of optogenetics is introduced, followed by the review of several novel structures of optoprobes, which are divided into multifunctional optoprobes integrated with microfluidic channels, artifact-free optoprobes, three-dimensional drivable optoprobes, and flexible optoprobes. At last, we introduce the fundamental perspectives of magnetoresistive (MR) sensors and then review the research progress of magnetrodes based on it.
Collapse
Affiliation(s)
- Jiahui Luo
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ning Xue
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jiamin Chen
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
3
|
Naveen NR, Girirajasekhar D, Goudanavar PS, Kumar CB, Narasimha GL. Prospection of Microfluidics for Local Drug Delivery. Curr Drug Targets 2022; 23:1239-1251. [PMID: 35379132 DOI: 10.2174/1389450123666220404154710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 01/03/2022] [Accepted: 02/10/2022] [Indexed: 01/25/2023]
Abstract
Significant endeavors can be made to develop effective drug delivery systems. Nowadays, many of these novel systems have gained attention as they focus primarily on increasing the bioavailability and bioaccessibility of several drugs to finally minimize the side effects, thus improving the treatment's efficacy. Microfluidics systems are unquestionably a superior technology, which is currently revolutionizing the current chemical and biological studies, providing diminutive chip-scale devices that offer precise dosage, target-precise delivery, and controlled release. Microfluidic systems have emerged as a promising delivery vehicle owing to their potential for defined handling and transporting of small liquid quantities. The latest microfabrication developments have been made for application to several biological systems. Here, we review the fundamentals of microfluidics and their application for local drug delivery.
Collapse
Affiliation(s)
- Nimbagal R Naveen
- Department of Pharmaceutics, Sri Adichunchanagiri College of Pharmacy, Adichunchanagiri University, B.G. Nagar, Karnataka 571448, India
| | | | - Prakash S Goudanavar
- Department of Pharmaceutics, Sri Adichunchanagiri College of Pharmacy, Adichunchanagiri University, B.G. Nagar, Karnataka 571448, India
| | - Chagaleti B Kumar
- Department of Pharmaceutical Chemistry, Akshaya Institute of Pharmacy, Lingapura, Tumkur, Karnataka 572106, India
| | - Gunturu L Narasimha
- Department of Pharmacy Practice, Annamacharya College of Pharmacy, New Boyanapalli, Rajampet, India
| |
Collapse
|
4
|
Coles L, Oluwasanya PW, Karam N, Proctor CM. Fluidic enabled bioelectronic implants: opportunities and challenges. J Mater Chem B 2022; 10:7122-7131. [PMID: 35959561 PMCID: PMC9518646 DOI: 10.1039/d2tb00942k] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Accepted: 07/26/2022] [Indexed: 11/21/2022]
Abstract
Bioelectronic implants are increasingly facilitating novel strategies for clinical diagnosis and treatment. The integration of fluidic technologies into such implants enables new complementary routes for sensing and therapy alongside electrical interaction. Indeed, these two technologies, electrical and fluidic, can work synergistically in a bioelectronics implant towards the fabrication of a complete therapeutic platform. In this perspective article, the leading applications of fluidic enabled bioelectronic implants are highlighted and methods of operation and material choices are discussed. Furthermore, a forward-looking perspective is offered on emerging opportunities as well as critical materials and technological challenges.
Collapse
Affiliation(s)
- Lawrence Coles
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.
| | - Pelumi W Oluwasanya
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.
| | - Nuzli Karam
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.
| | - Christopher M Proctor
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.
| |
Collapse
|
5
|
Wan J, Zhou S, Mea HJ, Guo Y, Ku H, Urbina BM. Emerging Roles of Microfluidics in Brain Research: From Cerebral Fluids Manipulation to Brain-on-a-Chip and Neuroelectronic Devices Engineering. Chem Rev 2022; 122:7142-7181. [PMID: 35080375 DOI: 10.1021/acs.chemrev.1c00480] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Remarkable progress made in the past few decades in brain research enables the manipulation of neuronal activity in single neurons and neural circuits and thus allows the decipherment of relations between nervous systems and behavior. The discovery of glymphatic and lymphatic systems in the brain and the recently unveiled tight relations between the gastrointestinal (GI) tract and the central nervous system (CNS) further revolutionize our understanding of brain structures and functions. Fundamental questions about how neurons conduct two-way communications with the gut to establish the gut-brain axis (GBA) and interact with essential brain components such as glial cells and blood vessels to regulate cerebral blood flow (CBF) and cerebrospinal fluid (CSF) in health and disease, however, remain. Microfluidics with unparalleled advantages in the control of fluids at microscale has emerged recently as an effective approach to address these critical questions in brain research. The dynamics of cerebral fluids (i.e., blood and CSF) and novel in vitro brain-on-a-chip models and microfluidic-integrated multifunctional neuroelectronic devices, for example, have been investigated. This review starts with a critical discussion of the current understanding of several key topics in brain research such as neurovascular coupling (NVC), glymphatic pathway, and GBA and then interrogates a wide range of microfluidic-based approaches that have been developed or can be improved to advance our fundamental understanding of brain functions. Last, emerging technologies for structuring microfluidic devices and their implications and future directions in brain research are discussed.
Collapse
Affiliation(s)
- Jiandi Wan
- Department of Chemical Engineering, University of California, Davis, California 95616, United States
| | - Sitong Zhou
- Department of Chemical Engineering, University of California, Davis, California 95616, United States
| | - Hing Jii Mea
- Department of Chemical Engineering, University of California, Davis, California 95616, United States
| | - Yaojun Guo
- Department of Electrical and Computer Engineering, University of California, Davis, California 95616, United States
| | - Hansol Ku
- Department of Electrical and Computer Engineering, University of California, Davis, California 95616, United States
| | - Brianna M Urbina
- Biochemistry, Molecular, Cellular and Developmental Biology Program, University of California, Davis, California 95616, United States
| |
Collapse
|
6
|
Szabo E, Hess-Dunning A. Irreversible, Self-Aligned Microfluidic Packaging for Chronic Implant Applications. JOURNAL OF MICROMECHANICS AND MICROENGINEERING : STRUCTURES, DEVICES, AND SYSTEMS 2021; 31:1-10. [PMID: 35431469 PMCID: PMC9009276 DOI: 10.1088/1361-6439/ac1994] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Packaging is an often overlooked component in microfluidic devices for biomedical implant applications. Robust and reliable connectors to interface microscale and macroscale features are especially critical for chronic implant applications. Existing microfluidic packaging methods are incompatible with emerging polymeric materials designed to enhance device integration with the surrounding tissue. A microfluidic connector scheme was developed to promote compatibility with novel materials and implant applications. The connectors and an adhesive wax were printed on a scaffold via additive manufacturing processes. The low-temperature packaging process entailed bonding the connector to a polymer nanocomposite-based intracortical microfluidic probe using an adhesive wax. The robustness of the packaging was assessed by measuring the tensile and shear bond strengths of the connector-adhesive wax-polymer film interface. After soak testing for 4 weeks, the bond strength continued to exceed the force required to infuse fluids through the microfluidic channel. Further, the shear bond strength exceeded typical probe insertion forces by at least 10-fold. These results support the use of the connector and thermal bonding method as a viable option for chronic implant applications.
Collapse
Affiliation(s)
- Emily Szabo
- Case Western Reserve University, Cleveland, OH 44106, USA
| | - Allison Hess-Dunning
- Case Western Reserve University, Cleveland, OH 44106, USA
- Rehabilitation Research and Development, Louis Stokes Cleveland VA Medical Center, Cleveland, OH 44106, USA
- Advanced Platform Technology Center, Cleveland, OH 44106, USA
| |
Collapse
|
7
|
Ramezani Z, Seo KJ, Fang H. Hybrid Electrical and Optical Neural Interfaces. JOURNAL OF MICROMECHANICS AND MICROENGINEERING : STRUCTURES, DEVICES, AND SYSTEMS 2021; 31:044002. [PMID: 34177136 PMCID: PMC8232899 DOI: 10.1088/1361-6439/abeb30] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Neural interfaces bridge the nervous system and the outside world by recording and stimulating neurons. Combining electrical and optical modalities in a single, hybrid neural interface system could lead to complementary and powerful new ways to explore the brain. It has gained robust and exciting momentum recently in neuroscience and neural engineering research. Here, we review developments in the past several years aiming to achieve such hybrid electrical and optical microsystem platforms. Specifically, we cover three major categories of technological advances: transparent neuroelectrodes, optical neural fibers with electrodes, and neural probes/grids integrating electrodes and microscale light-emitting diodes. We discuss examples of these probes tailored to combine electrophysiological recording with optical imaging or optical neural stimulation of the brain and possible directions of future innovation.
Collapse
Affiliation(s)
| | | | - Hui Fang
- Department of Electrical and Computer Engineering
- Department of Mechanical and Industrial Engineering
- Department of Bioengineering, Northeastern University, Boston, Massachusetts 02115, USA
| |
Collapse
|
8
|
Zhang W, Zhou X, He Y, Xu L, Xie J. Implanting mechanics of PEG/DEX coated flexible neural probe: impacts of fabricating methods. Biomed Microdevices 2021; 23:17. [PMID: 33730217 DOI: 10.1007/s10544-021-00552-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/10/2021] [Indexed: 12/15/2022]
Abstract
Resorbable coatings are processed on flexible implants to facilitate penetrations. However, impacts of fabricating methods on implantation damage of coated probes are unclear. Herein, photosensitive polyimide (PSPI) based flexible neural implants are fabricated through clean-room technology. Polyethyleneglycol (PEG) - dexamethasone (DEX) coatings are processed through an improved micro moulding protocol in micro channels, fabricated by computer-numerical-controlled (CNC) micro milling, laser machining, and deep reactive ion etching (DRIE), respectively. An in vitro testing system is developed, using maximum insertion force [Formula: see text] and mean region-of-interest strain [Formula: see text] to accurately evaluate effects of the three fabricating methods on implantation damage at different insertion speed. Rat cerebrum, agarose gel, and silicone rubber are used as brain phantoms for tests. Results show that lower insertion speed, and micro channels fabricated by CNC micro milling or DRIE can minimize implantation damage. The decrease of insertion speed from 2.0 mm/s to 0.5 mm/s reduces [Formula: see text] by 76.2% ~85.1% and [Formula: see text] by 11.6% ~14.7%, respectively. Compared with laser machining, CNC micro milling and DRIE ensure dimensional accuracy of the PEG/DEX coating, reducing [Formula: see text] by 20.2% ~51.4% and [Formula: see text] by 8.0% ~11.6%, respectively. Compared with biological rat cerebrum, [Formula: see text] reduces by 5.8% ~25.1% in agarose gel phantom and increases by 7.7% ~21.0% in silicone rubber phantom, respectively. This study improves processing methods of polymer coatings and reveals mechanical difference between current used abiotic brain phantoms and biological brain tissues. Implantation tests establish quantitative relationship among insertion speed, fabricating methods, and implantation damage.
Collapse
Affiliation(s)
- Wenguang Zhang
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China.
| | - Xuhui Zhou
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yuxin He
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Liyue Xu
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jie Xie
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
9
|
Kollo M, Racz R, Hanna ME, Obaid A, Angle MR, Wray W, Kong Y, Müller J, Hierlemann A, Melosh NA, Schaefer AT. CHIME: CMOS-Hosted in vivo Microelectrodes for Massively Scalable Neuronal Recordings. Front Neurosci 2020; 14:834. [PMID: 32848584 PMCID: PMC7432274 DOI: 10.3389/fnins.2020.00834] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2020] [Accepted: 07/16/2020] [Indexed: 01/20/2023] Open
Abstract
Mammalian brains consist of 10s of millions to 100s of billions of neurons operating at millisecond time scales, of which current recording techniques only capture a tiny fraction. Recording techniques capable of sampling neural activity at high spatiotemporal resolution have been difficult to scale. The most intensively studied mammalian neuronal networks, such as the neocortex, show a layered architecture, where the optimal recording technology samples densely over large areas. However, the need for application-specific designs as well as the mismatch between the three-dimensional architecture of the brain and largely two-dimensional microfabrication techniques profoundly limits both neurophysiological research and neural prosthetics. Here, we discuss a novel strategy for scalable neuronal recording by combining bundles of glass-ensheathed microwires with large-scale amplifier arrays derived from high-density CMOS in vitro MEA systems or high-speed infrared cameras. High signal-to-noise ratio (<25 μV RMS noise floor, SNR up to 25) is achieved due to the high conductivity of core metals in glass-ensheathed microwires allowing for ultrathin metal cores (down to <1 μm) and negligible stray capacitance. Multi-step electrochemical modification of the tip enables ultra-low access impedance with minimal geometric area, which is largely independent of the core diameter. We show that the microwire size can be reduced to virtually eliminate damage to the blood-brain-barrier upon insertion and we demonstrate that microwire arrays can stably record single-unit activity. Combining microwire bundles and CMOS arrays allows for a highly scalable neuronal recording approach, linking the progress in electrical neuronal recordings to the rapid progress in silicon microfabrication. The modular design of the system allows for custom arrangement of recording sites. Our approach of employing bundles of minimally invasive, highly insulated and functionalized microwires to extend a two-dimensional CMOS architecture into the 3rd dimension can be translated to other CMOS arrays, such as electrical stimulation devices.
Collapse
Affiliation(s)
- Mihaly Kollo
- Neurophysiology of Behaviour Laboratory, Francis Crick Institute, London, United Kingdom
- Department of Neuroscience, Physiology and Pharmacology, University College London, London, United Kingdom
| | - Romeo Racz
- Neurophysiology of Behaviour Laboratory, Francis Crick Institute, London, United Kingdom
| | - Mina-Elraheb Hanna
- Department of Materials Science and Engineering, Stanford University, Stanford, CA, United States
- Paradromics, Inc., Austin, TX, United States
| | - Abdulmalik Obaid
- Department of Materials Science and Engineering, Stanford University, Stanford, CA, United States
| | | | - William Wray
- Neurophysiology of Behaviour Laboratory, Francis Crick Institute, London, United Kingdom
| | - Yifan Kong
- Paradromics, Inc., Austin, TX, United States
| | - Jan Müller
- ETH Zürich, Department of Biosystems Science and Engineering, Basel, Switzerland
- MaxWell Biosystems AG, Zurich, Switzerland
| | - Andreas Hierlemann
- ETH Zürich, Department of Biosystems Science and Engineering, Basel, Switzerland
| | - Nicholas A. Melosh
- Department of Materials Science and Engineering, Stanford University, Stanford, CA, United States
| | - Andreas T. Schaefer
- Neurophysiology of Behaviour Laboratory, Francis Crick Institute, London, United Kingdom
- Department of Neuroscience, Physiology and Pharmacology, University College London, London, United Kingdom
| |
Collapse
|
10
|
Zhang R, Ye Z, Gao M, Gao C, Zhang X, Li L, Gui L. Liquid metal electrode-enabled flexible microdroplet sensor. LAB ON A CHIP 2020; 20:496-504. [PMID: 31840725 DOI: 10.1039/c9lc00995g] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This study presented a flexible liquid metal-based microdroplet capacitive sensor that would simply and accurately measure the speed and length of droplets flowing in microchannels. A pair of coplanar U-shaped electrodes was used to form a capacitance through droplet microchannels. Liquid metal was injected into polydimethylsiloxane (PDMS) channels to form the U-shaped electrodes. The sensor would generate a multi-plateau capacitance waveform as a droplet passes through the sensing area, and each plateau period corresponds to the droplet position in the sensing area. The droplet speed and length would be directly calculated from the multi-plateau capacitance waveform. The errors for the capacitive result relative to the real value were <7.2% for length and <2.8% for speed. Moreover, the sensor still maintained excellent performance for droplet length and speed measurement even though the microfluidic chip was bent to 96°. We have demonstrated that the capacitive sensor would be used for sweat rate monitoring.
Collapse
Affiliation(s)
- Renchang Zhang
- Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidu District, Beijing 10019, China. and University of Chinese Academy of Sciences, 19 Yuquan road, Shijingshan District, Beijing 100039, China
| | - Zi Ye
- Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidu District, Beijing 10019, China. and University of Chinese Academy of Sciences, 19 Yuquan road, Shijingshan District, Beijing 100039, China
| | - Meng Gao
- Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidu District, Beijing 10019, China.
| | - Chang Gao
- Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidu District, Beijing 10019, China. and University of Chinese Academy of Sciences, 19 Yuquan road, Shijingshan District, Beijing 100039, China
| | - Xudong Zhang
- Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidu District, Beijing 10019, China. and University of Chinese Academy of Sciences, 19 Yuquan road, Shijingshan District, Beijing 100039, China
| | - Lei Li
- Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidu District, Beijing 10019, China.
| | - Lin Gui
- Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidu District, Beijing 10019, China. and University of Chinese Academy of Sciences, 19 Yuquan road, Shijingshan District, Beijing 100039, China
| |
Collapse
|
11
|
Fallahi H, Zhang J, Phan HP, Nguyen NT. Flexible Microfluidics: Fundamentals, Recent Developments, and Applications. MICROMACHINES 2019; 10:E830. [PMID: 31795397 PMCID: PMC6953028 DOI: 10.3390/mi10120830] [Citation(s) in RCA: 90] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 11/26/2019] [Accepted: 11/26/2019] [Indexed: 12/20/2022]
Abstract
Miniaturization has been the driving force of scientific and technological advances over recent decades. Recently, flexibility has gained significant interest, particularly in miniaturization approaches for biomedical devices, wearable sensing technologies, and drug delivery. Flexible microfluidics is an emerging area that impacts upon a range of research areas including chemistry, electronics, biology, and medicine. Various materials with flexibility and stretchability have been used in flexible microfluidics. Flexible microchannels allow for strong fluid-structure interactions. Thus, they behave in a different way from rigid microchannels with fluid passing through them. This unique behaviour introduces new characteristics that can be deployed in microfluidic applications and functions such as valving, pumping, mixing, and separation. To date, a specialised review of flexible microfluidics that considers both the fundamentals and applications is missing in the literature. This review aims to provide a comprehensive summary including: (i) Materials used for fabrication of flexible microfluidics, (ii) basics and roles of flexibility on microfluidic functions, (iii) applications of flexible microfluidics in wearable electronics and biology, and (iv) future perspectives of flexible microfluidics. The review provides researchers and engineers with an extensive and updated understanding of the principles and applications of flexible microfluidics.
Collapse
Affiliation(s)
| | | | | | - Nam-Trung Nguyen
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD 4111, Australia; (H.F.); (J.Z.); (H.-P.P.)
| |
Collapse
|
12
|
Rezvantalab S, Keshavarz Moraveji M. Microfluidic assisted synthesis of PLGA drug delivery systems. RSC Adv 2019; 9:2055-2072. [PMID: 35516107 PMCID: PMC9059828 DOI: 10.1039/c8ra08972h] [Citation(s) in RCA: 75] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Accepted: 12/16/2018] [Indexed: 12/28/2022] Open
Abstract
Poly(lactic-co-glycolic acid) (PLGA) is a biocompatible and biodegradable polymer that recently attracted attention for use as part of drug delivery systems (DDS). In this context, there is an emerging need for a rapid, reliable and reproducible method of synthesis. Here, microfluidic systems provide great opportunities for synthesizing carriers in a tightly controlled manner and with low consumption of materials, energy and time. These miniature devices have been the focus of recent research since they can address the challenges inherent to the bulk system, e.g. low drug loading efficiency and encapsulation, broad size distribution and burst initial release. In this article, we provide an overview of current microfluidic systems used in drug delivery production, with a special focus on PLGA-based DDS. In this context, we highlight the advantages associated with the use of microchip systems in the fabrication of nanoparticles (NPs) and microparticles (MPs), e.g. in achieving complex morphologies. Furthermore, we discuss the challenges for selecting proper microfluidics for targeted DDS production in a translational setting and introduce strategies that are used to overcome microfluidics shortcomings, like low throughput for production. Poly(lactic-co-glycolic acid) (PLGA) is a biocompatible and biodegradable polymer that recently attracted attention for use as part of drug delivery systems (DDS).![]()
Collapse
Affiliation(s)
- Sima Rezvantalab
- Department of Chemical Engineering
- Amirkabir University of Technology (Tehran Polytechnic)
- Tehran
- Iran
| | | |
Collapse
|
13
|
Ecker M, Joshi-Imre A, Modi R, Frewin CL, Garcia-Sandoval A, Maeng J, Gutierrez-Heredia G, Pancrazio JJ, Voit WE. From softening polymers to multimaterial based bioelectronic devices. ACTA ACUST UNITED AC 2018. [DOI: 10.1088/2399-7532/aaed58] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
14
|
|
15
|
Lecomte A, Descamps E, Bergaud C. A review on mechanical considerations for chronically-implanted neural probes. J Neural Eng 2018; 15:031001. [DOI: 10.1088/1741-2552/aa8b4f] [Citation(s) in RCA: 100] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
16
|
Lo MC, Wang S, Singh S, Damodaran VB, Ahmed I, Coffey K, Barker D, Saste K, Kals K, Kaplan HM, Kohn J, Shreiber DI, Zahn JD. Evaluating the in vivo glial response to miniaturized parylene cortical probes coated with an ultra-fast degrading polymer to aid insertion. J Neural Eng 2018; 15:036002. [PMID: 29485103 DOI: 10.1088/1741-2552/aa9fad] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Despite the feasibility of short-term neural recordings using implantable microelectrodes, attaining reliable, chronic recordings remains a challenge. Most neural recording devices suffer from a long-term tissue response, including gliosis, at the device-tissue interface. It was hypothesized that smaller, more flexible intracortical probes would limit gliosis by providing a better mechanical match with surrounding tissue. APPROACH This paper describes the in vivo evaluation of flexible parylene microprobes designed to improve the interface with the adjacent neural tissue to limit gliosis and thereby allow for improved recording longevity. The probes were coated with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)) polymer that provides temporary mechanical support for device implantation, yet degrades within 2 h post-implantation. A parametric study of probes of varying dimensions and polymer coating thicknesses were implanted in rat brains. The glial tissue response and neuronal loss were assessed from 72 h to 24 weeks post-implantation via immunohistochemistry. MAIN RESULTS Experimental results suggest that both probe and polymer coating sizes affect the extent of gliosis. When an appropriate sized coating dimension (100 µm × 100 µm) and small probe (30 µm × 5 µm) was implanted, a minimal post-implantation glial response was observed. No discernible gliosis was detected when compared to tissue where a sham control consisting of a solid degradable polymer shuttle of the same dimensions was inserted. A larger polymer coating (200 µm × 200 µm) device induced a more severe glial response at later time points, suggesting that the initial insertion trauma can affect gliosis even when the polymer shuttle degrades rapidly. A larger degree of gliosis was also observed when comparing a larger sized probe (80 µm × 5 µm) to a smaller probe (30 µm × 5 µm) using the same polymer coating size (100 µm × 100 µm). There was no significant neuronal loss around the implantation sites for most device candidates except the group with largest polymer coating and probe sizes. SIGNIFICANCE These results suggest that: (1) the degree of mechanical trauma at device implantation and mechanical mismatches at the probe-tissue interface affect long term gliosis; (2) smaller, more flexible probes may minimize the glial response to provide improved tissue biocompatibility when used for chronic neural signal recording; and (3) some degree of glial scarring did not significantly affect neuronal distribution around the probe.
Collapse
Affiliation(s)
- Meng-Chen Lo
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ, United States of America
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Uguz I, Proctor CM, Curto VF, Pappa AM, Donahue MJ, Ferro M, Owens RM, Khodagholy D, Inal S, Malliaras GG. A Microfluidic Ion Pump for In Vivo Drug Delivery. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2017; 29:1701217. [PMID: 28503731 DOI: 10.1002/adma.201701217] [Citation(s) in RCA: 58] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Revised: 03/25/2017] [Indexed: 06/07/2023]
Abstract
Implantable devices offer an alternative to systemic delivery of drugs for the treatment of neurological disorders. A microfluidic ion pump (µFIP), capable of delivering a drug without the solvent through electrophoresis, is developed. The device is characterized in vitro by delivering γ-amino butyric acid to a target solution, and demonstrates low-voltage operation, high drug-delivery capacity, and high ON/OFF ratio. It is also demonstrated that the device is suitable for cortical delivery in vivo by manipulating the local ion concentration in an animal model and altering neural behavior. These results show that µFIPs represent a significant step forward toward the development of implantable drug-delivery systems.
Collapse
Affiliation(s)
- Ilke Uguz
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 13541, Gardanne, France
| | - Christopher M Proctor
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 13541, Gardanne, France
| | - Vincenzo F Curto
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 13541, Gardanne, France
| | - Anna-Maria Pappa
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 13541, Gardanne, France
| | - Mary J Donahue
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 13541, Gardanne, France
| | - Magali Ferro
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 13541, Gardanne, France
| | - Róisín M Owens
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 13541, Gardanne, France
| | - Dion Khodagholy
- Department of Electrical Engineering, Columbia University, NY, 10027, USA
| | - Sahika Inal
- Biological and Environmental Science and Engineering, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Kingdom of Saudi Arabia
| | - George G Malliaras
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 13541, Gardanne, France
| |
Collapse
|
18
|
Yalikun Y, Hosokawa Y, Iino T, Tanaka Y. An all-glass 12 μm ultra-thin and flexible micro-fluidic chip fabricated by femtosecond laser processing. LAB ON A CHIP 2016; 16:2427-33. [PMID: 27225521 DOI: 10.1039/c6lc00132g] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
This study investigated and established a method, using femtosecond laser processing, to fabricate a 100%-glass-based 12 μm ultra-thin and flexible micro-fluidic chip. First we investigated the suitable pulse energy of the laser to fabricate ultra-thin glass sheets and then we fabricated a prototype glass micro-fluidic chip. Two 1 mm-in-diameter orifices for facilitating alignment in the bonding step and one channel with a width of 20 μm and a length of 25 mm were fabricated in a 4 μm thickness ultra-thin glass sheet using the femtosecond laser; this forms layer 2 in the completed device. Next, the glass sheet with the channel was sandwiched between another glass sheet having an inlet hole and an outlet hole (layer 1) and a base glass sheet (layer 3); the three sheets were bonded to each other, resulting in a flexible, 100%-glass micro-fluidic chip with a thickness of approximately 12 μm and a weight of 3.6 mg. The basic function of the glass micro-fluidic chip was confirmed by flowing 1 and 2 μm in-diameter bead particles through the channel. The fabrication method clearly scales down the thickness limitation of flexible glass devices and offers a possible element technology for fabricating ultra-thin glass devices that can be applied to convection-enhanced delivery, implantable medical devices, wearable devices, and high-resolution imaging of small biological objects such as bacteria and proteins in the channel.
Collapse
Affiliation(s)
- Yaxiaer Yalikun
- Laboratory for Integrated Biodevice, Quantitative Biology Center, RIKEN, Suita, Osaka, Japan.
| | | | | | | |
Collapse
|
19
|
Modeling the Insertion Mechanics of Flexible Neural Probes Coated with Sacrificial Polymers for Optimizing Probe Design. SENSORS 2016; 16:s16030330. [PMID: 26959021 PMCID: PMC4813905 DOI: 10.3390/s16030330] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Revised: 02/18/2016] [Accepted: 02/29/2016] [Indexed: 01/20/2023]
Abstract
Single-unit recording neural probes have significant advantages towards improving signal-to-noise ratio and specificity for signal acquisition in brain-to-computer interface devices. Long-term effectiveness is unfortunately limited by the chronic injury response, which has been linked to the mechanical mismatch between rigid probes and compliant brain tissue. Small, flexible microelectrodes may overcome this limitation, but insertion of these probes without buckling requires supporting elements such as a stiff coating with a biodegradable polymer. For these coated probes, there is a design trade-off between the potential for successful insertion into brain tissue and the degree of trauma generated by the insertion. The objective of this study was to develop and validate a finite element model (FEM) to simulate insertion of coated neural probes of varying dimensions and material properties into brain tissue. Simulations were performed to predict the buckling and insertion forces during insertion of coated probes into a tissue phantom with material properties of brain. The simulations were validated with parallel experimental studies where probes were inserted into agarose tissue phantom, ex vivo chick embryonic brain tissue, and ex vivo rat brain tissue. Experiments were performed with uncoated copper wire and both uncoated and coated SU-8 photoresist and Parylene C probes. Model predictions were found to strongly agree with experimental results (<10% error). The ratio of the predicted buckling force-to-predicted insertion force, where a value greater than one would ideally be expected to result in successful insertion, was plotted against the actual success rate from experiments. A sigmoidal relationship was observed, with a ratio of 1.35 corresponding to equal probability of insertion and failure, and a ratio of 3.5 corresponding to a 100% success rate. This ratio was dubbed the “safety factor”, as it indicated the degree to which the coating should be over-designed to ensure successful insertion. Probability color maps were generated to visually compare the influence of design parameters. Statistical metrics derived from the color maps and multi-variable regression analysis confirmed that coating thickness and probe length were the most important features in influencing insertion potential. The model also revealed the effects of manufacturing flaws on insertion potential.
Collapse
|
20
|
Sunwoo SH, Kim TI. Materials and Designs for Multimodal Flexible Neural Probes. STRETCHABLE BIOELECTRONICS FOR MEDICAL DEVICES AND SYSTEMS 2016. [DOI: 10.1007/978-3-319-28694-5_15] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
21
|
Lo MC, Wang S, Singh S, Damodaran VB, Kaplan HM, Kohn J, Shreiber DI, Zahn JD. Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion. Biomed Microdevices 2015; 17:34. [PMID: 25681971 PMCID: PMC4827618 DOI: 10.1007/s10544-015-9927-z] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We report a fabrication process for coating neural probes with an ultrafast degrading polymer to create consistent and reproducible devices for neural tissue insertion. The rigid polymer coating acts as a probe insertion aid, but resorbs within hours post-implantation. Despite the feasibility for short term neural recordings from currently available neural prosthetic devices, most of these devices suffer from long term gliosis, which isolates the probes from adjacent neurons, increasing the recording impedance and stimulation threshold. The size and stiffness of implanted probes have been identified as critical factors that lead to this long term gliosis. Smaller, more flexible probes that match the mechanical properties of brain tissue could allow better long term integration by limiting the mechanical disruption of the surrounding tissue during and after probe insertion, while being flexible enough to deform with the tissue during brain movement. However, these small flexible probes inherently lack the mechanical strength to penetrate the brain on their own. In this work, we have developed a micromolding method for coating a non-functional miniaturized SU-8 probe with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)). Coated, non-functionalized probes of varying dimensions were reproducibly fabricated with high yields. The polymer erosion/degradation profiles of the probes were characterized in vitro. The probes were also mechanically characterized in ex vivo brain tissue models by measuring buckling and insertion forces during probe insertion. The results demonstrate the ability to produce polymer coated probes of consistent quality for future in vivo use, for example to study the effects of different design parameters that may affect tissue response during long term chronic intra-cortical microelectrode neural recordings.
Collapse
Affiliation(s)
- Meng-chen Lo
- Department of Biomedical Engineering, Rutgers, the State University of New Jersey, Piscataway, NJ, USA,
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Kang YJ, Yeom E, Seo E, Lee SJ. Bubble-free and pulse-free fluid delivery into microfluidic devices. BIOMICROFLUIDICS 2014; 8:014102. [PMID: 24753723 PMCID: PMC3982455 DOI: 10.1063/1.4863355] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2013] [Accepted: 01/15/2014] [Indexed: 05/26/2023]
Abstract
The bubble-free and pulse-free fluid delivery is critical to reliable operation of microfluidic devices. In this study, we propose a new method for stable bubble-free and pulse-free fluid delivery in a microfluidic device. Gas bubbles are separated from liquid by using the density difference between liquid and gas in a closed cavity. The pulsatile flow caused by a peristaltic pump is stabilized via gas compressibility. To demonstrate the proposed method, a fluidic chamber which is composed of two needles for inlet and outlet, one needle for a pinch valve and a closed cavity is carefully designed. By manipulating the opening or closing of the pinch valve, fluids fill up the fluidic chamber or are delivered into a microfluidic device through the fluidic chamber in a bubble-free and pulse-free manner. The performance of the proposed method in bubble-free and pulse-free fluid delivery is quantitatively evaluated. The proposed method is then applied to monitor the temporal variations of fluidic flows of rat blood circulating within a complex fluidic network including a rat, a pinch valve, a reservoir, a peristaltic pump, and the microfluidic device. In addition, the deformability of red blood cells and platelet aggregation are quantitatively evaluated from the information on the temporal variations of blood flows in the microfluidic device. These experimental demonstrations confirm that the proposed method is a promising tool for stable, bubble-free, and pulse-free supply of fluids, including whole blood, into a microfluidic device. Furthermore, the proposed method will be used to quantify the biophysical properties of blood circulating within an extracorporeal bypass loop of animal models.
Collapse
Affiliation(s)
- Yang Jun Kang
- Center for Biofluid and Biomimic Research, Pohang University of Science and Technology, Pohang, South Korea ; Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang, South Korea
| | - Eunseop Yeom
- Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang, South Korea
| | - Eunseok Seo
- Division of Integrative Biosciences and Biotechnology, Pohang University of Science and Technology, Pohang, South Korea
| | - Sang-Joon Lee
- Center for Biofluid and Biomimic Research, Pohang University of Science and Technology, Pohang, South Korea ; Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang, South Korea
| |
Collapse
|
23
|
Design, fabrication and characterization of drug delivery systems based on lab-on-a-chip technology. Adv Drug Deliv Rev 2013; 65:1403-19. [PMID: 23726943 DOI: 10.1016/j.addr.2013.05.008] [Citation(s) in RCA: 105] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2012] [Revised: 05/16/2013] [Accepted: 05/22/2013] [Indexed: 11/23/2022]
Abstract
Lab-on-a-chip technology is an emerging field evolving from the recent advances of micro- and nanotechnologies. The technology allows the integration of various components into a single microdevice. Microfluidics, the science and engineering of fluid flow in microscale, is the enabling underlying concept for lab-on-a-chip technology. The present paper reviews the design, fabrication and characterization of drug delivery systems based on this amazing technology. The systems are categorized and discussed according to the scales at which the drug is administered. Starting with the fundamentals on scaling laws of mass transfer and basic fabrication techniques, the paper reviews and discusses drug delivery devices for cellular, tissue and organism levels. At the cellular level, a concentration gradient generator integrated with a cell culture platform is the main drug delivery scheme of interest. At the tissue level, the synthesis of smart particles as drug carriers using lab-on-a-chip technology is the main focus of recent developments. At the organism level, microneedles and implantable devices with fluid-handling components are the main drug delivery systems. For drug delivery to a small organism that can fit into a microchip, devices similar to those of cellular level can be used.
Collapse
|
24
|
Altuna A, Bellistri E, Cid E, Aivar P, Gal B, Berganzo J, Gabriel G, Guimerà A, Villa R, Fernández LJ, Menendez de la Prida L. SU-8 based microprobes for simultaneous neural depth recording and drug delivery in the brain. LAB ON A CHIP 2013; 13:1422-1430. [PMID: 23407672 DOI: 10.1039/c3lc41364k] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
While novel influential concepts in neuroscience bring the focus to local activities generated within a few tens of cubic micrometers in the brain, we are still devoid of appropriate tools to record and manipulate pharmacologically neuronal activity at this fine scale. Here we designed, fabricated and encapsulated microprobes for simultaneous depth recording and drug delivery using exclusively the polymer SU-8 as structural material. A tetrode- and linear-like electrode patterning was combined for the first time with single and double fluidic microchannels for independent drug delivery. The device was tested experimentally using the in vivo anesthetized rat preparation. Both probe types successfully recorded detailed spatiotemporal features of local field potentials and single-cell activity at a resolution never attained before with integrated fluidic probes. Drug delivery was achieved with high spatial and temporal precision in a range from tens of nanoliters to a few microliters, as confirmed histologically. These technological advancements will foster a wide range of neural applications aimed at simultaneous monitoring of brain activity and delivery at a very precise micrometer scale.
Collapse
Affiliation(s)
- Ane Altuna
- MEMS/MST Department, Ikerlan S. Coop., Mondragón, Spain.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Jiang CP, Chen YY, Hsieh MF, Lee HM. Solid freeform fabrication and in-vitro response of osteoblast cells of mPEG-PCL-mPEG bone scaffolds. Biomed Microdevices 2013; 15:369-79. [DOI: 10.1007/s10544-013-9740-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
26
|
Jiang CP, Chen YY, Hsieh MF. Biofabrication and in vitro study of hydroxyapatite/mPEG-PCL-mPEG scaffolds for bone tissue engineering using air pressure-aided deposition technology. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2012; 33:680-90. [PMID: 25427474 DOI: 10.1016/j.msec.2012.10.018] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2012] [Revised: 09/25/2012] [Accepted: 10/26/2012] [Indexed: 01/21/2023]
Abstract
The aims of this study were to fabricate biopolymer and biocomposite scaffolds for bone tissue engineering by an air pressure-aided deposition system and to carry out osteoblast cell culture tests to validate the biocompatibility of fabricated scaffolds. A mPEG-PCL-mPEG triblock copolymer was synthesized as a biopolymer material. Biocomposite material was composed of synthesized biopolymer and hydroxyapatite (HA) with a mean diameter of 100 μm. The weight ratio of HA added to the synthesized biopolymer was 0.1, 0.25, 0.5 and 1. The experimental results show that the maximum average compressive strength of biocomposite scaffolds, made of weight ratio 0.5, with mean pore size of 410 μm (porosity 81%) is 18.38 MPa which is two times stronger than that of biopolymer scaffolds. Osteoblast cells, MC3T3-E1, were seeded on both types of fabricated scaffolds to validate the biocompatibility using methylthianzol tetrazolium (MTT) assay and cell morphology observation. After 28 days of in vitro culturing, the seeded osteoblasts were well distributed in the interior of both types of scaffolds. Furthermore, MTT experimental results show that the cell viability of the biocomposite scaffold is higher than that of the biopolymer scaffold. This indicates that adding HA into synthesized biopolymer can enhance compressive strength and the proliferation of the osteoblast cell.
Collapse
Affiliation(s)
- Cho-Pei Jiang
- Department of Power Mechanical Engineering, National Formosa University, Yunlin County, Taiwan.
| | - Yo-Yu Chen
- Institute of Mechanical and Electro-Mechanical Engineering, National Formosa University, Yunlin County, Taiwan.
| | - Min-Fa Hsieh
- Department of Biomedical Engineering, Chung Yuan Christian University, Chung Li, Taiwan.
| |
Collapse
|
27
|
Kim JH, Astary GW, Nobrega TL, Kantorovich S, Carney PR, Mareci TH, Sarntinoranont M. Dynamic contrast-enhanced MRI of Gd-albumin delivery to the rat hippocampus in vivo by convection-enhanced delivery. J Neurosci Methods 2012; 209:62-73. [PMID: 22687936 PMCID: PMC4192715 DOI: 10.1016/j.jneumeth.2012.05.024] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2011] [Revised: 04/20/2012] [Accepted: 05/22/2012] [Indexed: 01/08/2023]
Abstract
Convection-enhanced delivery (CED) shows promise in treating neurological diseases due to its ability to circumvent the blood-brain barrier (BBB) and deliver therapeutics directly to the parenchyma of the central nervous system (CNS). Such a drug delivery method may be useful in treating CNS disorders involving the hippocampus such as temporal lobe epilepsy and gliomas; however, the influence of anatomical structures on infusate distribution is not fully understood. As a surrogate for therapeutic agents, we used gadolinium-labeled-albumin (Gd-albumin) tagged with Evans Blue dye to observe the time dependence of CED infusate distributions into the rat dorsal and ventral hippocampus in vivo with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). For finer anatomical detail, final distribution volumes (V(d)) of the infusate were observed with high-resolution T(1)-weighted MR imaging and light microscopy of fixed brain sections. Dynamic images demonstrated that Gd-albumin preferentially distributed within the hippocampus along neuroanatomical structures with less fluid resistance and less penetration was observed in dense cell layers. Furthermore, significant leakage into adjacent cerebrospinal fluid (CSF) spaces such as the hippocampal fissure, velum interpositum and midbrain cistern occurred toward the end of infusion. V(d) increased linearly with infusion volume (V(i)) at a mean V(d)/V(i) ratio of 5.51 ± 0.55 for the dorsal hippocampus infusion and 5.30 ± 0.83 for the ventral hippocampus infusion. This study demonstrated the significant effects of tissue structure and CSF space boundaries on infusate distribution during CED.
Collapse
Affiliation(s)
- Jung Hwan Kim
- Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL
| | - Garrett W. Astary
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL
| | - Tatiana L. Nobrega
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL
| | | | - Paul R. Carney
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL
- Department of Neuroscience, University of Florida, Gainesville, FL
- Division of Pediatric Neurology, University of Florida, Gainesville, FL
| | - Thomas H. Mareci
- Department of Biochemistry and Molecular Biology, University of Florida, Gainesville, FL
| | - Malisa Sarntinoranont
- Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL
| |
Collapse
|
28
|
Frey O, van der Wal PD, Spieth S, Brett O, Seidl K, Paul O, Ruther P, Zengerle R, de Rooij NF. Biosensor microprobes with integrated microfluidic channels for bi-directional neurochemical interaction. J Neural Eng 2011; 8:066001. [DOI: 10.1088/1741-2560/8/6/066001] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
29
|
Lewitus DY, Landers J, Branch J, Smith KL, Callegari G, Kohn J, Neimark AV. Biohybrid Carbon Nanotube/Agarose Fibers for Neural Tissue Engineering. ADVANCED FUNCTIONAL MATERIALS 2011; 21:2624-2632. [PMID: 21887125 PMCID: PMC3163387 DOI: 10.1002/adfm.201002429] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
We report a novel approach for producing carbon nanotube fibers (CNF) composed with the polysaccharide agarose. Current attempts to make CNF's require the use of a polymer or precipitating agent in the coagulating bath that may have negative effects in biomedical applications. We show that by taking advantage of the gelation properties of agarose one can substitute the bath with distilled water or ethanol and hence reduce the complexity associated with alternating the bath components or the use of organic solvents. We also demonstrate that these CNF can be chemically functionalized to express biological moieties through available free hydroxyl groups in agarose. We corroborate that agarose CNF are not only conductive and nontoxic, but their functionalization can facilitate cell attachment and response both in vitro and in vivo. Our findings suggest that agarose/CNT hybrid materials are excellent candidates for applications involving neural tissue engineering and biointerfacing with the nervous system.
Collapse
Affiliation(s)
- Dan Y. Lewitus
- The New Jersey Center for Biomaterials, and Department of Biomedical Engineering Rutgers, the State University of New Jersey, 145 Bevier rd. Piscataway, NJ, 08854 (USA)
| | - John Landers
- Department of Chemical and Biochemical Engineering, Rutgers, State University of New Jersey, Piscataway, NJ, 08854, USA
| | - Jonathan Branch
- The New Jersey Center for Biomaterials, and Department of Biomedical Engineering Rutgers, the State University of New Jersey, 145 Bevier rd. Piscataway, NJ, 08854 (USA)
| | - Karen L. Smith
- Wadsworth Center, New York State Department of Health, 1 Government Center, Albany NY, 12201 (USA)
| | - Gerardo Callegari
- The Center for Modeling and Characterization of Nanoporous Materials, TRI/Princeton, Princeton, NJ 08542 USA
| | - Joachim Kohn
- The New Jersey Center for Biomaterials, and Department of Biomedical Engineering Rutgers, the State University of New Jersey, 145 Bevier rd. Piscataway, NJ, 08854 (USA)
| | - Alexander V. Neimark
- Department of Chemical and Biochemical Engineering, Rutgers, State University of New Jersey, Piscataway, NJ, 08854, USA
| |
Collapse
|
30
|
Lewitus D, Smith KL, Shain W, Kohn J. Ultrafast resorbing polymers for use as carriers for cortical neural probes. Acta Biomater 2011; 7:2483-91. [PMID: 21345383 DOI: 10.1016/j.actbio.2011.02.027] [Citation(s) in RCA: 77] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2010] [Revised: 02/10/2011] [Accepted: 02/15/2011] [Indexed: 12/14/2022]
Abstract
We have identified a polymeric system based on a novel tyrosine-derived terpolymer that offers desirable insertion capability for flexible neural prosthetic devices. To test this concept, flexible films were coated with this terpolymer and their suitability for peranchyma insertion was visualized. The effect of the polymer on neural recording was evaluated using coated microwire probes. The stiff but readily resorbable polymer rapidly degrades (molecular weight half-life of 170 min) while turning into a soft gel, followed by complete resorption within 240 min. This polymeric platform maintains sufficient stiffness to facilitate pial penetration with a dry elastic modulus of 393±44 MPa but loses its strength within 30 min once immersed in saline. In vitro, the polymer's ability to locally deliver dexamethasone has been confirmed through a first order release profile over a 360 min period. In vitro, coated microwire probes regained their original impedance values of 0.5 KΩ within 20 min of wetting via water absorption and polymer resorption. In vivo, the retention of electrical recording capability was also demonstrated through multiple waveform detection in live animals. The ultrafast resorbing polymer as a platform to facilitate the implantation of micronized flexible probes can be utilized in future designs of chronic neural devices.
Collapse
|
31
|
Lewitus DY, Smith KL, Shain W, Bolikal D, Kohn J. The fate of ultrafast degrading polymeric implants in the brain. Biomaterials 2011; 32:5543-50. [PMID: 21609850 DOI: 10.1016/j.biomaterials.2011.04.052] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2011] [Accepted: 04/20/2011] [Indexed: 12/30/2022]
Abstract
We have recently reported on an ultrafast degrading tyrosine-derived terpolymer that degrades and resorbs within hours, and is suitable for use in cortical neural prosthetic applications. Here we further characterize this polymer, and describe a new tyrosine-derived fast degrading terpolymer in which the poly(ethylene glycol) (PEG) is replaced by poly(trimethylene carbonate) (PTMC). This PTMC containing terpolymer showed similar degradation characteristics but its resorption was negligible in the same period. Thus, changes in the polymer chemistry allowed for the development of two ultrafast degrading polymers with distinct difference in resorption properties. The in vivo tissue response to both polymers used as intraparenchymal cortical devices was compared to poly(lactic-co-glycolic acid) (PLGA). Slow resorbing, indwelling implant resulted in continuous glial activation and loss of neural tissue. In contrast, the fast degrading tyrosine-derived terpolymer that is also fast resorbing, significantly reduced both the glial response in the implantation site and the neuronal exclusion zone. Such polymers allow for brain tissue recovery, thus render them suitable for neural interfacing applications.
Collapse
Affiliation(s)
- Dan Y Lewitus
- New Jersey Center for Biomaterials, Rutgers, The State University of New Jersey, 145 Bevier Rd., Piscataway, NJ 08854, USA.
| | | | | | | | | |
Collapse
|
32
|
Park CG, Kim E, Park M, Park JH, Choy YB. A nanofibrous sheet-based system for linear delivery of nifedipine. J Control Release 2010; 149:250-7. [PMID: 21035511 DOI: 10.1016/j.jconrel.2010.10.023] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2010] [Revised: 10/13/2010] [Accepted: 10/17/2010] [Indexed: 11/25/2022]
Abstract
We developed a nanofibrous sheet-based system to achieve linear release of nifedipine for oral delivery. The nanofibrous sheets of micro-porosity were fabricated by the electrospinning method, using a biocompatible polymer, poly (lactic-co-glycolic acid). The sheets were then used as a drug diffusion barrier by capping and sealing a compressed tablet, composed of nifedipine and a solubility enhancer, polyvinylpyrrolidone. The nanofibrous sheets of different thicknesses were prepared to vary the rate of drug diffusion in this work. In vitro drug release study revealed that as the sheet thickness increased, drug release was more retarded, where a lag phase of drug release became more evident. We were to realize linear drug release by combining two distinctly capped tablets, each showing a different drug release, which exhibited an almost linear release of nifedipine during 24h (R(2)>0.986). The drug release profile was not influenced by the pH of the release media as the morphological structure of nanofibrous sheets was seen to be not very different at both pHs 1.2 and 6.8. Therefore, we conclude that a combination of two tablets, each capped with nanofibrous sheets of different thickness, is a promising system for linear delivery of oral drug.
Collapse
Affiliation(s)
- Chun Gwon Park
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul, 152-742, Republic of Korea
| | | | | | | | | |
Collapse
|
33
|
Regional convection-enhanced delivery of gadolinium-labeled albumin in the rat hippocampus in vivo. J Neurosci Methods 2010; 187:129-37. [PMID: 20067808 DOI: 10.1016/j.jneumeth.2010.01.002] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2009] [Revised: 01/05/2010] [Accepted: 01/05/2010] [Indexed: 11/20/2022]
Abstract
Convection-enhanced delivery (CED) has emerged as a promising method of targeted drug delivery for treating central nervous system (CNS) disorders, but the influence of brain structure on infusate distribution is unclear. We have utilized this approach to study extracellular transport and distribution of a contrast agent in the hippocampus, a complex structure susceptible to CNS disorders. The magnetic resonance (MR) contrast agent diethylene triamene penta-acetic acid chelated gadolinium-labeled albumin (Gd-albumin), tagged with Evans blue dye, was directly infused (V(i)=5 microl) into the dorsal and ventral hippocampus of seven male Sprague-Dawley rats. The final distribution profile of the contrast agent, a product of CED and limited diffusion, was observed in vivo using high-resolution T1-weighted MR imaging at 11.1T. Dense cell layers, such as the granule cell layer of the dentate gyrus and the pyramidal cell layer of CA1, appeared to be barriers to transport of the tracer. Three-dimensional distribution shape and volume (V(d)) differences, between the dorsal and ventral hippocampus infusions, were determined from the MR images using a semi-automatic segmentation routine (dorsal V(d)=23.4+/-1.8 microl, ventral V(d)=36.4+/-5.1 microl). Finer structural detail of the hippocampus was obtained using a combination of histological analysis and fluorescence imaging. This study demonstrates that CED has the potential to target all regions of the hippocampus and that tracer distribution is influenced by infusion site, underlying structure and circuitry, and extent of backflow. Therefore, CED, combined with high-resolution MR imaging, may be a useful strategy for delivering therapeutics for the treatment of CNS disorders affecting the hippocampus.
Collapse
|