1
|
Wang W, Kan X. Multiquenching-Based Aggregation-Induced Electrochemiluminescence Sensing for Highly Sensitive Detection of the SARS-CoV-2 N Protein. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:16484-16491. [PMID: 39046807 DOI: 10.1021/acs.langmuir.4c01849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/27/2024]
Abstract
The rapid epidemic around the world of coronavirus disease 2019 (COVID-19), caused by the SARS-CoV-2 virus, proves the need and stimulates efforts to explore efficient diagnostic tests for the sensitive detection of the SARS-CoV-2 virus. An aggregation-induced electrochemiluminescence (AIECL) sensor was developed for the ultrasensitive detection of the SARS-CoV-2 nucleocapsid (N) protein in this work. Tetraphenylethylene doped in zeolite imidazole backbone-90 (TPE-ZIF-90) showed highly efficient aggregation-induced emission (AIE) to endow TPE-ZIF-90 with high ECL intensity. Upon the capture of the SARS-CoV-2 N protein by immune recognition, an alkaline phosphatase (ALP)-modified gold nanoparticle (AuNP)-decorated zinc oxide (ZnO) nanoflower (ALP/Au-ZnO) composite was introduced on the sensing platform, which catalyzed L-ascorbate-2-phosphate trisodium salt (AA2P) to produce PO43- and ascorbic acid (AA). Based on a multiquenching of the ECL signal strategy, including resonance energy transfer (RET) between TPE-ZIF-90 and Au-ZnO, disassembly of TPE-ZIF-90 triggered by the strong coordination between PO43- and Zn2+, and RET between TPE-ZIF-90 and AuNPs produced in situ by the AA reductive reaction, the constructed AIECL sensor achieved highly sensitive detection of the SARS-CoV-2 N protein with a low limit of detection of 0.52 fg/mL. With the merits of high specificity, good stability, and proven application ability, the present RET- and enzyme-triggered multiquenching AIECL sensor may become a powerful tool in the field of SARS-CoV-2 virus diagnosis.
Collapse
Affiliation(s)
- Wanlu Wang
- Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Laboratory of Molecule-Based Materials, Anhui Province Key Laboratory of Biomedical Materials and Chemical Measurement, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, China
| | - Xianwen Kan
- Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Laboratory of Molecule-Based Materials, Anhui Province Key Laboratory of Biomedical Materials and Chemical Measurement, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, China
| |
Collapse
|
2
|
Li J, Chu LT, Hartanto H, Guo G, Liu L, Wu J, Wu M, Cui C, Wang G, Liu W, Kwong HK, Wu S, Chen TH. Microfluidic particle counter visualizing mucosal antibodies against SARS-CoV-2 in the upper respiratory tract for rapid evaluation of immune protection. LAB ON A CHIP 2024; 24:2658-2668. [PMID: 38660972 DOI: 10.1039/d4lc00118d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
Mucosal antibodies in the upper respiratory tract are the earliest and most critical responders to prevent respiratory infections, providing an indication for the rapid evaluation of immune protection. Here, we report a microfluidic particle counter that directly visualizes mucosal antibody levels in nasal mucus. The mucosal anti-SARS-CoV-2 spike receptor binding domain (RBD) antibodies in nasal secretions first react with magnetic microparticles (MMPs) and polystyrene microparticles (PMPs) that are surface-modified to form a "MMPs-anti-spike RBD IgG-PMPs" complex when RBD is present. After magnetic separation and loading into the microfluidic particle counter, the free PMPs, which are reduced with increasing anti-spike RBD IgG antibody levels, are trapped by a microfluidic particle dam and accumulate in the trapping channel. A sensitive mode [limit of detection (LOD): 14.0 ng mL-1; sample-to-answer time: 70 min] and an equipment-free rapid mode (LOD: 37.4 ng mL-1; sample-to-answer time: 20 min) were achieved. Eighty-seven nasal secretion (NS) samples from vaccinees were analyzed using our microfluidic particle counter, and the results closely resemble those of the gold-standard enzyme-linked immunosorbent assay (ELISA). The analysis shows that higher antibody levels were found in convalescent volunteers compared to noninfected volunteers. Together, we demonstrate a rapid kit that directly indicates immune status, which can guide vaccine strategy for individuals and the government.
Collapse
Affiliation(s)
- Jiaheng Li
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
| | - Lok Ting Chu
- Department of Chemistry and Molecular Biology, School of Basic Medical Sciences, Guang Dong Medical University, Zhanjiang, China
| | - Hogi Hartanto
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
| | - Guihuan Guo
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
| | - Lu Liu
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
| | - Jianpeng Wu
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
| | - Minghui Wu
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
| | - Chenyu Cui
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering, Hong Kong Science Park, Hong Kong, SAR, China
| | - Gaobo Wang
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
| | - Wengang Liu
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
| | - Hoi Kwan Kwong
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
| | - Siying Wu
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
| | - Ting-Hsuan Chen
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR, China.
- City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering, Hong Kong Science Park, Hong Kong, SAR, China
| |
Collapse
|
3
|
Zhou Y, Zhao X, Jiang Y, Lin DJ, Lu C, Wang Y, Le S, Li R, Yan J. A Mechanical Assay for the Quantification of Anti-RBD IgG Levels in Finger-Prick Whole Blood. ACS Sens 2023; 8:2986-2995. [PMID: 37582229 PMCID: PMC10464602 DOI: 10.1021/acssensors.3c00393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 08/01/2023] [Indexed: 08/17/2023]
Abstract
A large portion of the global population has been vaccinated with various vaccines or infected with SARS-CoV-2, the virus that causes COVID-19. The resulting IgG antibodies that target the receptor binding domain (RBD) of SARS-CoV-2 play a vital role in reducing infection rates and severe disease outcomes. Different immune histories result in the production of anti-RBD IgG antibodies with different binding affinities to RBDs of different variants, and the levels of these antibodies decrease over time. Therefore, it is important to have a low-cost, rapid method for quantifying the levels of anti-RBD IgG in decentralized testing for large populations. In this study, we describe a 30 min assay that allows for the quantification of anti-RBD IgG levels in a single drop of finger-prick whole blood. This assay uses force-dependent dissociation of nonspecifically absorbed RBD-coated superparamagnetic microbeads to determine the density of specifically linked microbeads to a protein A-coated transparent surface through anti-RBD IgGs, which can be measured using a simple light microscope and a low-magnification lens. The titer of serially diluted anti-RBD IgGs can be determined without any additional sample processing steps. The limit of detection for this assay is 0.7 ± 0.1 ng/mL referenced to the CR3022 anti-RBD IgG. The limits of the technology and its potential to be further developed to meet the need for point-of-care monitoring of immune protection status are discussed.
Collapse
Affiliation(s)
- Yu Zhou
- Mechanobiology
Institute, National University of Singapore, 117411, Singapore
| | - Xiaodan Zhao
- Department
of Physics, National University of Singapore, 117542, Singapore
- Centre
for Bioimaging Sciences, National University
of Singapore, 117557, Singapore
| | - Yanqige Jiang
- Mechanobiology
Institute, National University of Singapore, 117411, Singapore
| | | | - Chen Lu
- Department
of Physics, National University of Singapore, 117542, Singapore
| | - Yinan Wang
- Department
of Physics, National University of Singapore, 117542, Singapore
| | - Shimin Le
- Department
of Physics, Xiamen University, Xiamen361005, P. R. China
| | - Rong Li
- Mechanobiology
Institute, National University of Singapore, 117411, Singapore
| | - Jie Yan
- Mechanobiology
Institute, National University of Singapore, 117411, Singapore
- Department
of Physics, National University of Singapore, 117542, Singapore
- Centre
for Bioimaging Sciences, National University
of Singapore, 117557, Singapore
- Joint
School of National University of Singapore and Tianjin University, International Campus of Tianjin University, Binhai New City, Fuzhou 350207, China
| |
Collapse
|
4
|
Zhu JH, Tai CH, Ping CF, Chou PH, Tsai YL, Chung S, Bradner L, Pentella M, Gauger P, Zhang J. Evaluation of a Sample-to-Result POCKIT Central SARS-CoV-2 PCR System. Diagnostics (Basel) 2023; 13:2219. [PMID: 37443612 DOI: 10.3390/diagnostics13132219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/15/2023] [Accepted: 06/23/2023] [Indexed: 07/15/2023] Open
Abstract
The emergence of COVID-19 has caused unprecedented impacts on global public health and many other aspects. Meanwhile, many types of methods have been developed to detect the causative agent, SARS-CoV-2; this has greatly advanced the technologies in the diagnostic field. Here, we describe the development and validation of a sample-in-result-out POCKIT Central SARS-CoV-2 PCR system for detecting SARS-CoV-2 in comparison with a commercial reference real-time RT-PCR assay (TaqPath COVID-19 Combo Kit). Both assays were specific and did not cross-react with non-SARS-CoV-2 agents. Both assays were able to detect various SARS-CoV-2 strains including some variants. Based on testing serial dilutions of SARS-CoV-2 USA-WA1/2020 isolate, the limit of detection was 0.8 TCID50/mL (1.87 × 103 genomic copies/mL) for POCKIT Central SARS-CoV-2 PCR and 0.16 TCID50/mL (3.75 × 102 genomic copies/mL) for the reference PCR. Subsequently, 183 clinical samples were tested by both assays and the diagnostic sensitivity, specificity, and agreement of the POCKIT Central SARS-CoV-2 PCR were 91.7%, 100%, and 94.0%, respectively, when compared to the reference PCR. The compact sample-to-result POCKIT Central SARS-CoV-2 PCR system is a simplified and efficient point-of-care tool for SARS-CoV-2 detection. In addition, this platform can be readily adapted to detect other human and animal viruses.
Collapse
Affiliation(s)
- Jin-Hui Zhu
- Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA 50011, USA
| | - Chia-Hsing Tai
- GeneReach Biotechnology Corporation, Taichung 407, Taiwan
| | - Chia-Fong Ping
- GeneReach Biotechnology Corporation, Taichung 407, Taiwan
| | - Pin-Hsing Chou
- GeneReach Biotechnology Corporation, Taichung 407, Taiwan
| | - Yun-Long Tsai
- GeneReach Biotechnology Corporation, Taichung 407, Taiwan
| | - Simon Chung
- GeneReach Biotechnology Corporation, Taichung 407, Taiwan
| | - Laura Bradner
- Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA 50011, USA
| | - Michael Pentella
- State Hygienic Laboratory, University of Iowa, Coralville, IA 52241, USA
| | - Phillip Gauger
- Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA 50011, USA
| | - Jianqiang Zhang
- Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA 50011, USA
| |
Collapse
|
5
|
Calvo Chica LE, Aguilar-Mora F, Ramirez Cando LJ, Proaño-Bolaños C, Carrera-Gonzales A. Cost and performance analysis of efficiency, efficacy, and effectiveness of viral RNA isolation with commercial kits and Heat Shock as an alternative method to detect SARS-CoV-2 by RT-PCR. BIONATURA 2023. [DOI: 10.21931/rb/2023.08.01.40] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2023] Open
Abstract
In late 2019 a new virus reported in Wuhan, China, identified as SARS-CoV-2 spread rapidly challenging the healthcare system around the world. The need for rapid, timely and accurate detection was critical to the prevention of community outbreaks of the virus. However, the high global demand for reagents during the years 2020 and 2021 generated a bottleneck in kits used for detection, greatly affecting developing countries, lagging their ability to diagnose and control the virus in the population. The difficulty in importing reagents, high costs and limited public access to the SARS-CoV-2 detection test led to the search for alternative methods. In this framework, different commercial nucleic acid extraction methodologies were evaluated and compared against heat shock as an alternative method for SARS-CoV-2 detection by RT-PCR, in order to determine the diagnostic yield and its possible low-cost compared to other methodologies. Nasopharyngeal samples were used where the diagnostic efficiency of the alternative method was 70 to 73%. The evaluation of the discriminatory efficacy of the method took the sensitivity and specificity to establish its cut-off point, being 0.73 to 0.817, which allows discriminating between COVID-19 positives and negatives. As for the diagnostic effectiveness expressed as the proportion of subjects correctly classified, it is between 80 and 84%. On the other hand, in terms of the costs necessary to carry out the detection, the alternative method is more economical and accessible in terms of direct cost close to 47 and 49 USD, and indirect cost around 35 and 50 USD compared to the commercial methods available in this comparison and evaluation, being possible its implementation in developing countries with high infection rates, allowing access to the diagnostic test with a reliable and low-cost method.
Keywords: COVID-19, RT-PCR, Viral RNA.
Collapse
Affiliation(s)
| | - Fabian Aguilar-Mora
- Faculty of Life Sciences, Universidad Regional Amazonica Ikiam, Tena, Ecuador. ; Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Mendoza, Argentina
| | - Lenin Javier Ramirez Cando
- School of Biological Sciences and Engineering. Yachay University for Experimental Technology and Research, San Miguel de Urcuquí, Proyecto Yachay, Ecuador
| | | | | |
Collapse
|
6
|
Sirijatuphat R, Leelarasamee A, Puangpet T, Thitithanyanont A. A Pilot Study of 0.4% Povidone-Iodine Nasal Spray to Eradicate SARS-CoV-2 in the Nasopharynx. Infect Drug Resist 2022; 15:7529-7536. [PMID: 36575672 PMCID: PMC9790155 DOI: 10.2147/idr.s391630] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Accepted: 12/09/2022] [Indexed: 12/24/2022] Open
Abstract
Purpose This study aimed to evaluate the virucidal efficacy of 0.4% povidone-iodine (PVP-I) nasal spray against SARS-CoV-2 in the patients' nasopharynx at 3 minutes and 4 hours after PVP-I exposure. Patients and Methods The study was an open-label, before and after design, single-arm pilot study of adult patients with RT-PCR-confirmed COVID-19 within 24 hours. All patients received three puffs of 0.4% PVP-I nasal spray in each nostril. Nasopharyngeal (NP) swabs were collected before the PVP-I spray (baseline, left NP samples), and at 3 minutes (left and right NP samples) and 4 hours post-PVP-I spray (right NP samples). All swabs were coded to blind assessors and transported to diagnostic laboratory and tested by RT-PCR and cultured to measure the viable SARS-CoV-2 within 24 hours after collection. Results Fourteen patients were enrolled but viable SARS-CoV-2 was cultured from 12 patients (85.7%). The median viral titer at baseline was 3.5 log TCID50/mL (IQR 2.8-4.0 log TCID50/mL). At 3 minutes post-PVP-I spray via the left nostril, viral titers were reduced in 8 patients (66.7%). At 3 minutes post-PVP-I, the median viral titer was 3.4 log TCID50/mL (IQR 1.8-4.4 log TCID50/mL) (P=0.162). At 4 hours post-PVP-I spray via the right nostril, 6 of 11 patients (54.5%) had either the same or minimal change in viral titers. The median viral titer 3 minutes post-PVP-I spray was 2.7 log TCID50/mL (IQR 2.0-3.9 log TCID50/mL). Four hours post-PVP-I spray the median titer was 2.8 log TCID50/mL (IQR 2.2-3.9 log TCID50/mL) (P=0.704). No adverse effects of 0.4% PVP-I nasal spray were detected. Conclusion The 0.4% PVP-I nasal spray demonstrated minimal virucidal efficacy at 3 minutes post-exposure. At 4 hours post-exposure, the viral titer was considerably unchanged from baseline in 10 cases. The 0.4% PVP-I nasal spray showed poor virucidal activity and is unlikely to reduce transmission of SARS-CoV-2 in prophylaxis use.
Collapse
Affiliation(s)
- Rujipas Sirijatuphat
- Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Amorn Leelarasamee
- Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand,Faculty of Medicine, Siam University, Bangkok, Thailand,Correspondence: Amorn Leelarasamee, Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, 2 Thanon Wang Lang, Siriraj, Bangkoknoi, Bangkok, 10700, Thailand, Tel/Fax +66 2 419 7783, Email
| | | | | |
Collapse
|
7
|
Fulawka L, Kuzan A. Molecular Diagnostic Tools against SARS-CoV-2 in Poland in 2022. Biomedicines 2022; 10:biomedicines10123259. [PMID: 36552015 PMCID: PMC9775127 DOI: 10.3390/biomedicines10123259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 12/12/2022] [Accepted: 12/13/2022] [Indexed: 12/23/2022] Open
Abstract
The most effective way to stop the spread of COVID-19 (coronavirus disease 2019) is to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and isolate those infected as soon as possible. More than 1000 types of molecular and antigen-based immunoassay tests to detect SARS-CoV-2 are now commercially available worldwide. In this review, we present the possibilities of molecular diagnostics available in Poland in 2022. We provide a description of what samples have proven useful to confirm SARS-CoV-2 infection, we describe what methods are used, as well as what safeguards can and should be used to prevent false-negative and false-positive results, and finally we review the products that diagnostic laboratories have to choose from. We also describe diagnostic problems associated with the mutation of the virus.
Collapse
Affiliation(s)
- Lukasz Fulawka
- Molecular Pathology Centre Cellgen, 50-353 Wroclaw, Poland
| | - Aleksandra Kuzan
- Department of Biochemistry and Immunochemistry, Wroclaw Medical University, 50-367 Wroclaw, Poland
- Correspondence: ; Tel.: +48-71-784-1379
| |
Collapse
|
8
|
Novel bridge multi-species ELISA for detection of SARS-CoV-2 antibodies. J Immunol Methods 2022; 511:113365. [PMID: 36202252 PMCID: PMC9529351 DOI: 10.1016/j.jim.2022.113365] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 09/28/2022] [Accepted: 09/28/2022] [Indexed: 11/06/2022]
Abstract
Considering the course of the current SARS-CoV-2 pandemic, it is important to have serological tests for monitoring humoral immune response against SARS-CoV-2 infection and vaccination. Herein we describe a novel bridge enzyme-linked immunosorbent assay (b-ELISA) for SARS-CoV-2 antibodies detection in human and other species, employing recombinant Spike protein as a unique antigen, which is produced at high scale in insect larvae. METHODS Eighty two human control sera/plasmas and 169 COVID-19 patients' sera/plasmas, confirmed by rRT-PCR, were analyzed by the b-ELISA assay. In addition, a total of 27 animal sera (5 horses, 13 rats, 2 cats and 7 dogs) were employed in order to evaluate the b-ELISA in other animal species. RESULTS Out of the 169 patient samples, 129 were positive for IgG anti-SARS-CoV-2 and 40 were negative when they were tested by ELISA COVIDAR® IgG. When a cut-off value of 5.0 SDs was established, 124 out of the 129 COVID-19 positive samples were also positive by our developed b-ELISA (sensitivity: 96.12%). Moreover, the test was able to evaluate the humoral immune response in animal models and also detected as positive a naturally infected cat and two dogs with symptoms, whose owners had suffered the COVID-19 disease. CONCLUSION The obtained results demonstrate that the method developed herein is versatile, as it is able to detect antibodies against SARS-CoV-2 in different animal species without the need to perform and optimize a new assay for each species.
Collapse
|
9
|
Wang Y, Li X, Wang Y, Tu Z, Xu J, Pan J, Zhou Q. Comparison of the performance of two real-time fluorescent quantitative PCR kits for the detection of SARS-CoV-2 nucleic acid: a study based on large real clinical samples. Virol J 2022; 19:191. [PMID: 36401275 PMCID: PMC9675236 DOI: 10.1186/s12985-022-01922-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 11/10/2022] [Indexed: 11/19/2022] Open
Abstract
Background The global pandemic of coronavirus disease 2019 (COVID-19) has led to the development of multiple detection kits by national manufacturers for severe acute respiratory syndrome coronavirus 2 viral nucleic acid testing. The purpose of this study is to evaluate the performance of different kits (i.e., Maccura kit and Sansure kit) in real clinical work using clinical samples, which will help with the optimization of the test kits. Method During the past three months (March–May 2022), 1399 pharyngeal swabs from suspected COVID-19 patients have been initially screened using the Maccura kit in Jilin, China, and the test results were verified using the Sansure kit. The cycle threshold (Ct) values generated by the two kits were compared at different viral load levels. Correlation and consistency of the Ct values were investigated using Spearman correlation, Deming regression, and Bland–Altman plots. The cut-off Ct values of the Maccura kit were recalculated by referencing the result of the Sansure kit as a standard. Furthermore, another 163 pharyngeal swabs from suspected COVID-19 patients were collected to verify the new cut-off values. Results As a result of the Maccura kit testing, 1192 positive cases and 207 suspected COVID-19 cases were verified. After re-examination by the Sansure kit, 1118 positive cases were confirmed. The difference between the Ct values provided by the two kits was statistically significant, except for the N gene at high viral load. The Ct values obtained from the two kits presented a linear positive correlation. The Maccura kit used new cut-off Ct values of 35.00 (ORF1ab gene) and 35.07 (N gene). Based on that, the validation pass rate for the new cut-off Ct values was 91.41%. Conclusion Since the Maccura kit is found to have false positives in actual clinical work, recalculation of the cut-off values can reduce this occurrence. In order to improve the accuracy of the testing, laboratories should use two kits for COVID-19 testing, and the adjusting and optimizing of the kits for their situation are needed.
Collapse
|
10
|
Tang Y, Li Y, Zhang S, Li J, Hu Y, Yang W, Chen Y, Qin C, Jiang T, Kang X. Preparation of the luciferase-labeled antibody for improving the detection sensitivity of viral antigen. Virol J 2022; 19:126. [PMID: 35902865 PMCID: PMC9332066 DOI: 10.1186/s12985-022-01855-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Accepted: 07/17/2022] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Viral antigen detection test is the most common method used to detect viruses in the field rapidly. However, due to the low sensitivity, it can only be used as an auxiliary diagnosis method for virus infection. Improving sensitivity is crucial for developing more accurate viral antigen tests. Nano luciferase (Nluc) is a sensitive reporter that has not been used in virus detection. RESULTS In this study, we produced an intracellularly Nluc labeled detection antibody (Nluc-ch2C5) and evaluated its ability to improve the detection sensitivity of respiratory syndrome coronavirus 2 (SARS-CoV-2) antigens. Compared with the traditional horse-radish peroxidase (HRP) labeled antibody (HRP-ch2C5), Nluc-ch2C5 was 41 times more sensitive for inactivated SARS-CoV-2 virus by sandwich chemiluminescence ELISA. Then we applied Nluc-ch2C5 to establish an automatic magnet chemiluminescence immune assay (AMCA) for the SARS-CoV-2 viral spike protein, the limit of detection was 68 pfu/reaction. The clinical sensitivity and specificity reached 75% (24/32) and 100% (48/48) using 32 PCR-positive and 48 PCR-negative swab samples for clinical evaluation, which is more sensitive than the commercial ELSA kit and colloid gold strip kit. CONCLUSIONS Here, monoclonal antibody ch2C5 served as a model antibody and the SARS-CoV-2 served as a model pathogen. The Nluc labeled detecting antibody (Nluc-ch2C5) significantly improved the detection sensitivity of SARS-CoV-2 antigen. This labeling principle applies to other viral infections, so this labeling and test format could be expected to play an important role in detecting other virus antigens.
Collapse
Affiliation(s)
- Ying Tang
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science. Institute of Microbiology and Epidemiology, No. 20 Dongda Street, Fengtai District, Beijing, 100071, China
| | - Yuchang Li
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science. Institute of Microbiology and Epidemiology, No. 20 Dongda Street, Fengtai District, Beijing, 100071, China
| | - Sen Zhang
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science. Institute of Microbiology and Epidemiology, No. 20 Dongda Street, Fengtai District, Beijing, 100071, China
| | - Jing Li
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science. Institute of Microbiology and Epidemiology, No. 20 Dongda Street, Fengtai District, Beijing, 100071, China
| | - Yi Hu
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science. Institute of Microbiology and Epidemiology, No. 20 Dongda Street, Fengtai District, Beijing, 100071, China
| | - Wenguang Yang
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science. Institute of Microbiology and Epidemiology, No. 20 Dongda Street, Fengtai District, Beijing, 100071, China
| | - Yuehong Chen
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science. Institute of Microbiology and Epidemiology, No. 20 Dongda Street, Fengtai District, Beijing, 100071, China
| | - Chengfeng Qin
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science. Institute of Microbiology and Epidemiology, No. 20 Dongda Street, Fengtai District, Beijing, 100071, China
| | - Tao Jiang
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science. Institute of Microbiology and Epidemiology, No. 20 Dongda Street, Fengtai District, Beijing, 100071, China
| | - Xiaoping Kang
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science. Institute of Microbiology and Epidemiology, No. 20 Dongda Street, Fengtai District, Beijing, 100071, China.
| |
Collapse
|
11
|
Zeng H, Liu H, Liu Z, Zhou X, Lu X, Yan Z, Zhou Y, Dai L, Chen Y, Yang T, Yin Z, Ye Z. Safety and immunogenicity of inactivated COVID-19 vaccination in adult rheumatic patients in South China: a prospective study. Hum Vaccin Immunother 2022; 18:2090176. [PMID: 35878733 PMCID: PMC9621074 DOI: 10.1080/21645515.2022.2090176] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Patients with rheumatic diseases (RD) are considered to be a high-risk population for infection with the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). The effectiveness of inactivated COVID-19 vaccinations (ICVs) was described as more effective than 95%. Despite this, no data on the immunogenicity and safety of the ICV in Han race stable RD patients in China. In this study, we sought to assess the safety and immunogenicity of the ICVs in RD patients in South China. A total of 80 adult stable RD patients were recruited. Following 14–35 days of immunization, cheiluminescence immunoassays (CLIA) were utilized to detect antibodies titers. An investigation into the relative parameters on the immunogenicity response to vaccination was carried out using logistic regression analysis. Compared to the HC group, the positive response of IgG and Nab in RD patients were lower than those in healthy control (HC) (P = .040 and P < .0001, respectively) after two doses of ICV were inoculated. The use of methotrexate (P = .016) and prednisolone (P = .018), and the level of red blood cell distribution width-C (RDW-C) (P = .035) and C-reactive protein (P = .015) were independently associated with lower rises in the magnitude of COVID-19 vaccine antibodies. No vaccine-related serious adverse reactions were observed in either group. After receiving two doses of ICVs, the production of protective antibodies in stable RD patients treated with immunosuppressive agents may decrease. It was discovered that ICVs were safe and well tolerated by RD patients.
What is the context?
There are currently no accessible data on the efficacy and safety of inactivated COVID-19 vaccinations in South China RD patients who are receiving immunosuppressive medications.
What is new?
Inactivated COVID-19 vaccinations were immunogenic in stable RD patients in our investigation. No significant adverse reactions to the vaccination were seen in either group. No disease flares were observed in our study.
What is the impact?
Inactivated COVID-19 vaccinations are immunogenic and safe in stable RD patients in China, according to the findings of this study. The use of methotrexate or prednisolone, the RDW-C level, and the CRP level may all have an effect on the development of protective antibodies following vaccination.
Collapse
Affiliation(s)
- Huiqiong Zeng
- Department of Rheumatology, Shenzhen Futian Hospital for Rheumatic Diseases, Shenzhen, Guangdong, China
| | - Hanjiang Liu
- Guangzhou Yusu Biomedical Technology Co., Haizhu District, Guangzhou, China
| | - Zhi Liu
- Department of Pulmonary Medicine & Tuberculosis, The Third People's Hospital of Shenzhen, Shenzhen, People's Republic of China
| | - Xiakai Zhou
- CAS Joint Laboratory on Stem Cell and Regenerative Medicine, The Chinese University of Hong Kong, School of Biomedical Sciences, CUHK-GIBH, Shatin, Hong Kong, Special Administrative Region of China
| | - Xiaoping Lu
- Department of Rheumatology, Shenzhen Futian Hospital for Rheumatic Diseases, Shenzhen, Guangdong, China
| | - Zhenbo Yan
- Department of Rheumatology, Shenzhen Futian Hospital for Rheumatic Diseases, Shenzhen, Guangdong, China
| | - Yan Zhou
- Department of Rheumatology, Shenzhen Futian Hospital for Rheumatic Diseases, Shenzhen, Guangdong, China
| | - Liping Dai
- Department of Rheumatology, Shenzhen Futian Hospital for Rheumatic Diseases, Shenzhen, Guangdong, China
| | - Yashuo Chen
- Department of Rheumatology, Shenzhen Futian Hospital for Rheumatic Diseases, Shenzhen, Guangdong, China
| | - Tingting Yang
- Department of Rheumatology, Shenzhen Futian Hospital for Rheumatic Diseases, Shenzhen, Guangdong, China
| | - Zhihua Yin
- Department of Rheumatology, Shenzhen Futian Hospital for Rheumatic Diseases, Shenzhen, Guangdong, China
| | - Zhizhong Ye
- Department of Rheumatology, Shenzhen Futian Hospital for Rheumatic Diseases, Shenzhen, Guangdong, China
| |
Collapse
|
12
|
Wu M, Wu S, Wang G, Liu W, Chu LT, Jiang T, Kwong HK, Chow HL, Li IWS, Chen TH. Microfluidic particle dam for direct visualization of SARS-CoV-2 antibody levels in COVID-19 vaccinees. SCIENCE ADVANCES 2022; 8:eabn6064. [PMID: 35658040 PMCID: PMC9166397 DOI: 10.1126/sciadv.abn6064] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Various COVID-19 vaccines are currently deployed, but their immunization varies and decays with time. Antibody level is a potent correlate to immune protection, but its quantitation relies on intensive laboratory techniques. Here, we report a decentralized, instrument-free microfluidic device that directly visualizes SARS-CoV-2 antibody levels. Magnetic microparticles (MMPs) and polystyrene microparticles (PMPs) can bind to SARS-CoV-2 antibodies simultaneously. In a microfluidic chip, this binding reduces the incidence of free PMPs escaping from magnetic separation and shortens PMP accumulation length at a particle dam. This visual quantitative result enables use in either sensitive mode [limit of detection (LOD): 13.3 ng/ml; sample-to-answer time: 70 min] or rapid mode (LOD: 57.8 ng/ml; sample-to-answer time: 20 min) and closely agrees with the gold standard enzyme-linked immunosorbent assay. Trials on 91 vaccinees revealed higher antibody levels in mRNA vaccinees than in inactivated vaccinees and their decay in 45 days, demonstrating the need for point-of-care devices to monitor immune protection.
Collapse
Affiliation(s)
- Minghui Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Siying Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Gaobo Wang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Wengang Liu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Lok Ting Chu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Tianyi Jiang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Hoi Kwan Kwong
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Hiu Lam Chow
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Iris Wai Sum Li
- HKU-Pasteur Research Pole, The University of Hong Kong, Pokfulam, Hong Kong Special Administrative Region, China
| | - Ting-Hsuan Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
- City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
- Corresponding author.
| |
Collapse
|
13
|
Li Y, Wang M, Wu H, Zhao H, Dong L, Li Y, Li X, Tang Y, Zhang S, Li J, Qin C, Jiang T, Deng Y, Kang X. Development of a rapid neutralizing antibody test for SARS-CoV-2 and its application for neutralizing antibody screening and vaccinated serum testing. INFECTIOUS MEDICINE 2022; 1:95-102. [PMID: 38073878 PMCID: PMC9040370 DOI: 10.1016/j.imj.2022.04.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 03/17/2022] [Accepted: 04/01/2022] [Indexed: 11/26/2022]
Abstract
Background Since the outbreak of coronavirus disease (COVID-19), the high infection rate and mutation frequency of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent, have contributed to the ongoing global pandemic. Vaccination has become the most effective means of controlling COVID-19. Traditional neutralizing tests of sera are complex and labor-intensive, therefore, a rapid test for detecting neutralizing antibodies and antibody status post-immunization is needed. Methods Based on the fact that antibodies exhibit neutralizing activity by blocking the binding of the S protein receptor-binding domain (S-RBD) to ACE2, we developed a rapid neutralizing antibody test, ACE2-Block-ELISA. To evaluate the sensitivity and specificity, we used 54 positive and 84 negative serum samples. We also tested the neutralizing activities of monoclonal antibodies (mAbs) and 214 sera samples from healthy individuals immunized with the inactivated SARS-CoV-2 vaccine. Results The sensitivity and specificity of the ACE2-Block ELISA were 96.3% and 100%, respectively. For neutralizing mAb screening, ch-2C5 was selected for its ability to block the ACE2-S-RBD interaction. A plaque assay confirmed that ch-2C5 neutralized SARS-CoV-2, with NT50 values of 4.19, 10.63, and 1.074 µg/mL against the SARS-CoV-2 original strain, and the Beta and Delta variants, respectively. For the immunized sera samples, the neutralizing positive rate dropped from 82.14% to 32.16% within 4 months post-vaccination. Conclusions This study developed and validated an ACE2-Block-ELISA to test the neutralizing activities of antibodies. As a rapid, inexpensive and easy-to-perform method, this ACE2-Block-ELISA has potential applications in rapid neutralizing mAb screening and SARS-CoV-2 vaccine evaluation.
Collapse
Affiliation(s)
- Yuchang Li
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science Institute of Microbiology and Epidemiology, Beijing, China
| | - Mingyue Wang
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science Institute of Microbiology and Epidemiology, Beijing, China
| | - Hongzhen Wu
- Beijing BGI-GBI Biotech Co., Ltd., Beijing, China
| | - Hui Zhao
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science Institute of Microbiology and Epidemiology, Beijing, China
| | - Lei Dong
- Clinical Laboratory Department, Air Force Medical Center, Beijing, China
| | - Yunfei Li
- Beijing BGI-GBI Biotech Co., Ltd., Beijing, China
| | - Xiaofeng Li
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science Institute of Microbiology and Epidemiology, Beijing, China
| | - Ying Tang
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science Institute of Microbiology and Epidemiology, Beijing, China
| | - Sen Zhang
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science Institute of Microbiology and Epidemiology, Beijing, China
| | - Jing Li
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science Institute of Microbiology and Epidemiology, Beijing, China
| | - Chengfeng Qin
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science Institute of Microbiology and Epidemiology, Beijing, China
| | - Tao Jiang
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science Institute of Microbiology and Epidemiology, Beijing, China
| | - Yongqiang Deng
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science Institute of Microbiology and Epidemiology, Beijing, China
| | - Xiaoping Kang
- State Key Laboratory of Pathogen and Biosecurity, The Academy of Military Medical Science Institute of Microbiology and Epidemiology, Beijing, China
| |
Collapse
|
14
|
Abstract
The COVID-19 pandemic remains a significant problem involving health systems worldwide. Several diagnostic methods are reported for detecting the coronavirus in clinical, research, and public health laboratories. rRT-PCR is considered the gold standard; however, as it required skilled personnel and special equipment, rapid antigen tests have been developed and used as first-line screening. The serologic testing of antibodies can also be used to enhance the detection sensitivity and accuracy, which are used to assess the overall infection rate. This review summarizes the molecular techniques and serologic assays widely used in China and discusses the advantages and disadvantages of these techniques.
Collapse
Affiliation(s)
- Yanjun Lu
- Department of Laboratory Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Ziyong Sun
- Department of Laboratory Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
| |
Collapse
|
15
|
Yu J, Qin Z, Liu X, He X, Yao J, Zhou X, Wen K, Yu N, Wu Q, Xiao W, Zhu L, Wan C, Zhang B, Zhao W. High-specificity targets in SARS-CoV-2 N protein for serological detection and distinction from SARS-CoV. Comput Biol Med 2022; 143:105272. [PMID: 35121361 PMCID: PMC8799378 DOI: 10.1016/j.compbiomed.2022.105272] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 01/14/2022] [Accepted: 01/24/2022] [Indexed: 12/18/2022]
Abstract
Numerous serological detection kits are being rapidly developed and approved for screening and diagnosing suspected coronavirus disease 2019 (COVID-19) cases. However, cross-reactivity between pre-existing antibodies against other coronaviruses and the captured antigens in these kits can affect detection accuracy, emphasizing the necessity for identifying highly specific antigen fragments for antibody detection. Thus, we performed a conservation and specificity analysis of the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid (N) protein. We also integrated various B-cell epitope prediction methods to obtain possible dominant epitope regions for the N protein, analyzed the differences in serological antibody levels for different epitopes using ELISA, and identified N protein epitopes for IgG and IgM with high-specificity. The SARS-CoV-2 N protein showed low mutation rates and shared the highest amino acid similarity with SARS-CoV; however, it differed substantially from other coronaviruses. Tests targeting the SARS-CoV-2 N protein produce strong positive results in patients recovering from SARS-CoV. The N18-39 and N183-197 epitopes for IgG and IgM detection, respectively, can effectively overcome cross-reactivity, and even exhibit good specificity between SARS-CoV-2 and SARS-CoV. The antibody levels detected with these were consistent with those detected using the complete N protein. These findings provide a basis for serological diagnosis and determining the kinetics of SARS-CoV-2 antibody detection in patients.
Collapse
Affiliation(s)
- Jianhai Yu
- Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, No. 1023, South Shatai Road, Guangzhou, Guangdong Province, 510515, China.
| | - Zhiran Qin
- Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, No. 1023, South Shatai Road, Guangzhou, Guangdong Province, 510515, China.
| | - Xuling Liu
- Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, No. 1023, South Shatai Road, Guangzhou, Guangdong Province, 510515, China.
| | - Xiaoen He
- Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, No. 1023, South Shatai Road, Guangzhou, Guangdong Province, 510515, China.
| | - Jinxiu Yao
- Yangjiang People's Hospital, No.42 Dongshan Road, Yangjiang, Guangdong Province, 529500, China.
| | - Xuan Zhou
- Department of Laboratory Medicine, Guangdong Second Provincial General Hospital, No. 466, Xingang Middle Road, Guangzhou, Guangdong Province, 510317, China.
| | - Kun Wen
- Division of Laboratory Medicine, Zhujiang Hospital, Southern Medical University, No. 253, Industrial Avenue Middle, Guangzhou, Guangdong Province, 510282, China.
| | - Nan Yu
- Division of Laboratory Medicine, Zhujiang Hospital, Southern Medical University, No. 253, Industrial Avenue Middle, Guangzhou, Guangdong Province, 510282, China.
| | - Qinghua Wu
- Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, No. 1023, South Shatai Road, Guangzhou, Guangdong Province, 510515, China.
| | - Weiwei Xiao
- Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, No. 1023, South Shatai Road, Guangzhou, Guangdong Province, 510515, China.
| | - Li Zhu
- Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, No. 1023, South Shatai Road, Guangzhou, Guangdong Province, 510515, China.
| | - Chengsong Wan
- Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, No. 1023, South Shatai Road, Guangzhou, Guangdong Province, 510515, China.
| | - Bao Zhang
- Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, No. 1023, South Shatai Road, Guangzhou, Guangdong Province, 510515, China.
| | - Wei Zhao
- Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, No. 1023, South Shatai Road, Guangzhou, Guangdong Province, 510515, China.
| |
Collapse
|
16
|
Tang Y, Wang Y, Li Y, Zhao H, Zhang S, Zhang Y, Li J, Chen Y, Wu X, Qin C, Jiang T, Kang X. An Integrated Rapid Nucleic Acid Detection Assay Based on Recombinant Polymerase Amplification for SARS-CoV-2. Virol Sin 2022; 37:138-141. [PMID: 35234627 PMCID: PMC8755414 DOI: 10.1016/j.virs.2022.01.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Accepted: 09/30/2021] [Indexed: 11/24/2022] Open
Abstract
I-RPA was developed by combining sample treatment and RPA detection in a single sealed cartridge. No cross reaction was found in respiratory tract-associated viruses. The low limit of detection was 35 copies/reaction. This I-RPA assay is suitable for detection and monitoring of SARS-CoV-2 in the field.
Collapse
|
17
|
Ahsan H. Monoplex and multiplex immunoassays: approval, advancements, and alternatives. COMPARATIVE CLINICAL PATHOLOGY 2021; 31:333-345. [PMID: 34840549 PMCID: PMC8605475 DOI: 10.1007/s00580-021-03302-4] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 11/03/2021] [Indexed: 02/07/2023]
Abstract
Immunoassays are a powerful diagnostic tool and are widely used for the quantification of proteins and biomolecules in medical diagnosis and research. Enzyme-linked immunosorbent assay (ELISA) is the most commonly used immunoassay format and allows the detection of biomarkers at a very low concentration. The diagnostic platforms such as enzyme immunoassay (EIA), chemiluminescence (CL) assay, polymerase chain reaction (PCR), flow cytometry (FC), and mass spectrometry (MS) have been used to identify molecular biomarkers. However, these diagnostic tools requiring expensive equipment, long testing time, and qualified personnel that is not always available in small local hospitals with limited resources. The lateral flow immunoassay (LFIA) platform was developed for rapidly obtaining laboratory results and to make urgent decisions in emergency medicine, as well as the recently introduced concept of testing at the site of care (point-of-care, POC). The simultaneous measurement of different substances from a single sample called multiplex assays have become increasingly significant for in vitro quantification of multiple analytes in a single sample, thereby minimising cost, time, and volume. In multiplex immunoassays, the ligands are immobilized either in planar format (flat surface) or on microspheres in suspension that binds to target analytes in sample. The multiplex technology has established itself in proteomic networks and pathways, validation of genomic discoveries, and in the development of clinical biomarkers. In the present review article, various types of monoplex/simplex and complex/multiplex immunoassays have been analysed that are increasingly being applied in laboratory medicine. Also, some advantages and disadvantages of these multiplex assays have also been included such as experimental animals, in vitro tests using cell lines and tissue samples, 3-dimensional modelling and bioprinting, in silico tests, organ-on-chip, and computer modelling.
Collapse
Affiliation(s)
- Haseeb Ahsan
- Department of Biochemistry, Faculty of Dentistry, Jamia Millia Islamia (A Central University), New Delhi - 110025, India
| |
Collapse
|
18
|
Brümmer LE, Katzenschlager S, Gaeddert M, Erdmann C, Schmitz S, Bota M, Grilli M, Larmann J, Weigand MA, Pollock NR, Macé A, Carmona S, Ongarello S, Sacks JA, Denkinger CM. Accuracy of novel antigen rapid diagnostics for SARS-CoV-2: A living systematic review and meta-analysis. PLoS Med 2021; 18:e1003735. [PMID: 34383750 PMCID: PMC8389849 DOI: 10.1371/journal.pmed.1003735] [Citation(s) in RCA: 173] [Impact Index Per Article: 43.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 08/26/2021] [Accepted: 07/14/2021] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND SARS-CoV-2 antigen rapid diagnostic tests (Ag-RDTs) are increasingly being integrated in testing strategies around the world. Studies of the Ag-RDTs have shown variable performance. In this systematic review and meta-analysis, we assessed the clinical accuracy (sensitivity and specificity) of commercially available Ag-RDTs. METHODS AND FINDINGS We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched multiple databases (PubMed, Web of Science Core Collection, medRvix, bioRvix, and FIND) for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 up until 30 April 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity in comparison to reverse transcription polymerase chain reaction (RT-PCR) testing. We assessed heterogeneity by subgroup analyses, and rated study quality and risk of bias using the QUADAS-2 assessment tool. From a total of 14,254 articles, we included 133 analytical and clinical studies resulting in 214 clinical accuracy datasets with 112,323 samples. Across all meta-analyzed samples, the pooled Ag-RDT sensitivity and specificity were 71.2% (95% CI 68.2% to 74.0%) and 98.9% (95% CI 98.6% to 99.1%), respectively. Sensitivity increased to 76.3% (95% CI 73.1% to 79.2%) if analysis was restricted to studies that followed the Ag-RDT manufacturers' instructions. LumiraDx showed the highest sensitivity, with 88.2% (95% CI 59.0% to 97.5%). Of instrument-free Ag-RDTs, Standard Q nasal performed best, with 80.2% sensitivity (95% CI 70.3% to 87.4%). Across all Ag-RDTs, sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values, i.e., <20 (96.5%, 95% CI 92.6% to 98.4%) and <25 (95.8%, 95% CI 92.3% to 97.8%), in comparison to those with Ct ≥ 25 (50.7%, 95% CI 35.6% to 65.8%) and ≥30 (20.9%, 95% CI 12.5% to 32.8%). Testing in the first week from symptom onset resulted in substantially higher sensitivity (83.8%, 95% CI 76.3% to 89.2%) compared to testing after 1 week (61.5%, 95% CI 52.2% to 70.0%). The best Ag-RDT sensitivity was found with anterior nasal sampling (75.5%, 95% CI 70.4% to 79.9%), in comparison to other sample types (e.g., nasopharyngeal, 71.6%, 95% CI 68.1% to 74.9%), although CIs were overlapping. Concerns of bias were raised across all datasets, and financial support from the manufacturer was reported in 24.1% of datasets. Our analysis was limited by the included studies' heterogeneity in design and reporting. CONCLUSIONS In this study we found that Ag-RDTs detect the vast majority of SARS-CoV-2-infected persons within the first week of symptom onset and those with high viral load. Thus, they can have high utility for diagnostic purposes in the early phase of disease, making them a valuable tool to fight the spread of SARS-CoV-2. Standardization in conduct and reporting of clinical accuracy studies would improve comparability and use of data.
Collapse
Affiliation(s)
- Lukas E. Brümmer
- Division of Tropical Medicine, Center for Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Mary Gaeddert
- Division of Tropical Medicine, Center for Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Stephani Schmitz
- Division of Tropical Medicine, Center for Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany
| | - Marc Bota
- Agaplesion Bethesda Hospital, Hamburg, Germany
| | - Maurizio Grilli
- Library, University Medical Center Mannheim, Mannheim, Germany
| | - Jan Larmann
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Markus A. Weigand
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Nira R. Pollock
- Department of Laboratory Medicine, Boston Children’s Hospital, Boston, Massachusetts, United States of America
| | | | | | | | | | - Claudia M. Denkinger
- Division of Tropical Medicine, Center for Infectious Diseases, Heidelberg University Hospital, Heidelberg, Germany
- Partner Site Heidelberg University Hospital, German Center for Infection Research (DZIF), Heidelberg, Germany
| |
Collapse
|
19
|
Di Nardo F, Chiarello M, Cavalera S, Baggiani C, Anfossi L. Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives. SENSORS (BASEL, SWITZERLAND) 2021; 21:5185. [PMID: 34372422 PMCID: PMC8348896 DOI: 10.3390/s21155185] [Citation(s) in RCA: 179] [Impact Index Per Article: 44.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 07/27/2021] [Accepted: 07/28/2021] [Indexed: 12/22/2022]
Abstract
The Lateral Flow Immunoassay (LFIA) is by far one of the most successful analytical platforms to perform the on-site detection of target substances. LFIA can be considered as a sort of lab-in-a-hand and, together with other point-of-need tests, has represented a paradigm shift from sample-to-lab to lab-to-sample aiming to improve decision making and turnaround time. The features of LFIAs made them a very attractive tool in clinical diagnostic where they can improve patient care by enabling more prompt diagnosis and treatment decisions. The rapidity, simplicity, relative cost-effectiveness, and the possibility to be used by nonskilled personnel contributed to the wide acceptance of LFIAs. As a consequence, from the detection of molecules, organisms, and (bio)markers for clinical purposes, the LFIA application has been rapidly extended to other fields, including food and feed safety, veterinary medicine, environmental control, and many others. This review aims to provide readers with a 10-years overview of applications, outlining the trends for the main application fields and the relative compounded annual growth rates. Moreover, future perspectives and challenges are discussed.
Collapse
Affiliation(s)
- Fabio Di Nardo
- Department of Chemistry, University of Torino, 10125 Torino, Italy; (M.C.); (S.C.); (C.B.); (L.A.)
| | | | | | | | | |
Collapse
|
20
|
Li X, Yin Y, Pang L, Xu S, Lu F, Xu D, Shen T. Colloidal gold immunochromatographic assay (GICA) is an effective screening method for identifying detectable anti-SARS-CoV-2 neutralizing antibodies. Int J Infect Dis 2021; 108:483-486. [PMID: 34091005 PMCID: PMC8180344 DOI: 10.1016/j.ijid.2021.05.080] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 05/28/2021] [Accepted: 05/31/2021] [Indexed: 01/20/2023] Open
Abstract
Introduction A large number of COVID-19 patients are in recovery, and millions of people are vaccinated for COVID-19 globally. This calls for a rapid screening strategy of SARS-CoV-2 protective antibodies, generated in rehabilitated and vaccinated populations. Methods Serum samples collected over a follow-up period of six months from 306 COVID-19 cases discharged from Wuhan Tongji Hospital were analyzed. Anti-S Abs were detected by colloidal gold immunochromatographic assay (GICA), and neutralizing antibodies (nAbs) were detected by chemiluminescent microparticle immunoassay (CMIA). Results Most COVID-19 survivors tested positive for anti-S Abs (83.7%) and nAbs (98.0%) 6 months after being discharged from the hospital, and the levels of anti-S Abs in the blood were highly positively correlated with nAbs (r = 0.652, P < 0.0001). The positivity rate of nAbs for patients with anti-S Abs positive was 100%. Conclusions There is a good agreement between anti-S Abs detected by GICA and nAbs detected by CMIA. It indicates that anti-S Abs detected by GICA may be used as a cheaper screening strategy for detectable SARS-CoV-2 nAbs in COVID-19 convalescent individuals.
Collapse
Affiliation(s)
- Xinjie Li
- Department of Microbiology and Infectious Disease Center, School of Basic Medical Sciences, Peking University, Beijing 100191, China.
| | - Yue Yin
- Department of Microbiology and Infectious Disease Center, School of Basic Medical Sciences, Peking University, Beijing 100191, China.
| | - Ling Pang
- Department of Infectious Disease, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
| | - Shuyun Xu
- Department of Respiratory and Critical Care Medicine, Key Laboratory of Pulmonary Diseases of Health Ministry, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
| | - Fengmin Lu
- Department of Microbiology and Infectious Disease Center, School of Basic Medical Sciences, Peking University, Beijing 100191, China.
| | - Dong Xu
- Department of Infectious Disease, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
| | - Tao Shen
- Department of Microbiology and Infectious Disease Center, School of Basic Medical Sciences, Peking University, Beijing 100191, China.
| |
Collapse
|