1
|
Mahmoud S, Bennett J, Jones B, Hosni M. A comparative analysis of potential aerosol exposure in a wide-body aircraft cabin using tracer gas and fluorescent particles. THE INTERNATIONAL JOURNAL OF VENTILATION 2024; 23:104-124. [PMID: 38799196 PMCID: PMC11120351 DOI: 10.1080/14733315.2023.2290920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 11/28/2023] [Indexed: 05/29/2024]
Abstract
We compare two aerosol surrogate tracers in aircraft cabins for breathing and coughing sources: tracer gas collected in the ACER Boeing 767 mock-up and fluorescent particles collected in an actual Boeing 767 aircraft by the US Transportation Command (TRANSCOM). Each source was located individually in window and middle seats. Exposure generally decreased with source distance. A window seat breathing source resulted in good agreement between datasets for exposure (as percent of release) for the TRANSCOM hangar-AFT testing mode, which corresponds to the 11-row cabin ACER laboratory space. Average tracer gas exposure for a middle seat breathing source was higher in the ACER study than the fluorescent particle tracer exposure in the TRANSCOM study. Using a coughing source in a window seat, the exposure for the TRANSCOM data was higher within the first two rows from the source before decreasing to and tracking with the ACER levels, until increasing after about 5 m away. A similar trend was recorded for a middle seat coughing source with higher overall exposure for the TRANSCOM data. Sources of exposure variation between the studies include particle deposition. This work helps optimize aerosol dispersion research in aircraft cabins and provides some validation to the existing studies.
Collapse
Affiliation(s)
- Seif Mahmoud
- National Institute for Occupational Safety and Health, Centres for Disease Control and Prevention, U.S. Department of Health and Human Services, Division of Field Studies and Engineering, Cincinnati, OH, USA
| | - James Bennett
- National Institute for Occupational Safety and Health, Centres for Disease Control and Prevention, U.S. Department of Health and Human Services, Division of Field Studies and Engineering, Cincinnati, OH, USA
| | - Byron Jones
- Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS, USA
| | - Mohammad Hosni
- Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS, USA
| |
Collapse
|
2
|
Vouriot CVM, van Reeuwijk M, Burridge HC. Uncertainties in exposure predictions arising from point measurements of carbon dioxide in classroom environments. J R Soc Interface 2024; 21:20240270. [PMID: 39439310 PMCID: PMC11496947 DOI: 10.1098/rsif.2024.0270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 06/28/2024] [Accepted: 08/16/2024] [Indexed: 10/25/2024] Open
Abstract
Predictions of airborne infection risk can be made based on the fraction of rebreathed air inferred from point measurements of carbon dioxide (CO[Formula: see text]). We investigate the extent to which environmental factors, particularly spatial variations due to the ventilation provision, affect the uncertainty in these predictions. Spatial variations are expected to be especially problematic in naturally ventilated spaces, which include the majority of classrooms in the UK. An idealized classroom, broadly representative of the physics of (buoyancy-driven) displacement ventilation, is examined using computational fluid dynamics, with different ventilation configurations. Passive tracers are used to model both the CO[Formula: see text] generated by all 32 occupants and the breath of a single infectious individual (located in nine different regions). The distribution of infected breath is shown to depend strongly on the distance from the release location but is also affected by the pattern of the ventilating flow, including the presence of stagnating regions. However, far-field exposure predictions based on single point measurements of CO[Formula: see text] within the breathing zone are shown to rarely differ from the actual exposure to infected breath by more than a factor of two-we argue this uncertainty is small compared with other uncertainties inherent in modelling airborne infection risk.
Collapse
Affiliation(s)
- Carolanne V. M. Vouriot
- School of Mechanical, Aerospace and Civil Engineering, University of Sheffield, Mappin Street, SheffieldS1 3JD, UK
- Department of Applied Mathematics and Theoretical Physics, Centre for Mathematical Sciences, University of Cambridge, Wilberforce Road, CambridgeCB3 0WA, UK
| | - Maarten van Reeuwijk
- Department of Civil and Environmental Engineering, Skempton Building, South Kensington Campus, Imperial College London, LondonSW7 2BX, UK
| | - Henry C. Burridge
- Department of Civil and Environmental Engineering, Skempton Building, South Kensington Campus, Imperial College London, LondonSW7 2BX, UK
| |
Collapse
|
3
|
Lee SJ, Lee WS, Roh JY, Lee SH, Kim ES, Yeo MS. Post-occupancy evaluation on temporary negative pressure isolation wards with portable high-efficiency particulate air filter units used during the COVID-19 pandemic in South Korea. Am J Infect Control 2024:S0196-6553(24)00692-8. [PMID: 39245359 DOI: 10.1016/j.ajic.2024.08.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 08/30/2024] [Accepted: 08/30/2024] [Indexed: 09/10/2024]
Abstract
BACKGROUND During the COVID-19 pandemic, in South Korea, several inpatient wards were converted to temporary negative pressure isolation (TNPI) wards by using portable high-efficiency particulate air filter units (PHUs). This study proposes improvements to the TNPI ward to prepare for airborne infections. METHODS Existing air-conditioning systems were investigated during the pandemic in 4 hospitals through a document review and field investigation with staff interviews. On-site experiments and measurements were conducted under vacant conditions. Differential pressure (∆P) between spaces was measured in all 4 hospitals, while tracer gas tests were carried out in 2 hospitals. RESULTS The investigation revealed that thermal discomfort caused the existing systems remaining perpetually active. Additionally, the noise generated by the PHU caused an unexpected shutdown of that equipment. Furthermore, the ∆P of over -2.5 Pa was measured as a result of the operating status of equipment. These situations can cause duct backflow and gas diffusion through unsealed diffusers. Moreover, low airtightness of existing facilities can affect indoor environment, pressure difference, and gas diffusion. CONCLUSIONS When using existing facilities as TNPI wards, the airtightness and existing systems should be considered. We concluded that it is important to increase the airtightness and seal unused diffusers in order to prevent cross-infection by unpredictable airflow.
Collapse
Affiliation(s)
- Se Jin Lee
- Department of Architecture and Architectural Engineering, Graduate School, Seoul National University, Seoul, South Korea
| | - Won Seok Lee
- Department of Architecture and Architectural Engineering, Graduate School, Seoul National University, Seoul, South Korea
| | - Joo Yeon Roh
- Department of Architecture and Architectural Engineering, Graduate School, Seoul National University, Seoul, South Korea
| | - Shin Hye Lee
- Department of Architecture and Architectural Engineering, Graduate School, Seoul National University, Seoul, South Korea
| | - Eun Seok Kim
- Seoul Public Health Research Institute, Seoul Medical Center, Seoul, South Korea
| | - Myoung Souk Yeo
- Department of Architecture and Architectural Engineering, College of Engineering, Seoul National University, Seoul, South Korea; Institute of Construction and Environmental Engineering (ICEE), Seoul National University, Seoul, South Korea.
| |
Collapse
|
4
|
Satheesan MK, Tsang TW, Wong LT, Mui KW. The air we breathe: Numerical investigation of ventilation strategies to mitigate airborne dispersion of MERS-CoV in inpatient wards. Heliyon 2024; 10:e26159. [PMID: 38404798 PMCID: PMC10884507 DOI: 10.1016/j.heliyon.2024.e26159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 01/03/2024] [Accepted: 02/08/2024] [Indexed: 02/27/2024] Open
Abstract
Ventilation strategies for infection control in hospitals has been predominantly directed towards isolation rooms and operating theatres, with relatively less emphasis on perceived low risk spaces, such as general wards. Typically, the ventilation systems in general wards are intended to optimize patient thermal comfort and energy conservation. The emission of pathogens from exhalation activity, such as sneezing, by an undiagnosed infectious patient admitted to general wards, is a significant concern for infection outbreaks. However, the ventilation guidelines for general wards with respect to infection control are vague. This research article presents a numerical study on the effect of varying air change rates (3 h-1, 6 h-1, 9 h-1, 13 h-1) and exhaust flow rates (10%, 50% of supply air quantity) on the concentration of airborne pathogens in a mechanically ventilated general inpatient ward. The findings imply that the breathing zone directly above the source patient has the highest level of pathogen exposure, followed by the breathing zones at the bedside and adjacent patients close to the source patient. The dispersion of pathogens throughout the ward over time is also apparent. However, a key difference while adopting a lower ACH (3 h-1) and a higher ACH (13 h-1) in this study was that the latter had a significantly lower number of suspended pathogens in the breathing zone than the former. Thus, this research suggests high ventilation rates for general wards, contrary to current ventilation standards. In addition, combining a higher air change rate (13 h-1) with a high exhaust flow rate (50% of supply air) through a local exhaust grille dramatically reduced suspended pathogens within the breathing zone, further mitigating the risk of pathogen exposure for ward users. Therefore, this study presents an effective ventilation technique to dilute and eliminate airborne infectious pathogens, minimizing their concentration and the risk of infection.
Collapse
Affiliation(s)
- Manoj Kumar Satheesan
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong SAR, China
| | - Tsz Wun Tsang
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong SAR, China
| | - Ling Tim Wong
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong SAR, China
| | - Kwok Wai Mui
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong SAR, China
| |
Collapse
|
5
|
Jiang X, Zhao C, Chen Y, Gao X, Zhang Q, Chen Z, Li C, Zhao X, Liu Z, Huang W, Xie W, Yue Y. Probable Evidence of Aerosol Transmission of SARS-COV-2 in a COVID-19 Outbreak of a High-Rise Building. ENVIRONMENTAL HEALTH INSIGHTS 2023; 17:11786302231188269. [PMID: 37522029 PMCID: PMC10372516 DOI: 10.1177/11786302231188269] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 06/29/2023] [Indexed: 08/01/2023]
Abstract
Although it is well established that severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can be transmitted through aerosols, the mode of long-range aerosol transmission in high-rise buildings remains unclear. In this study, we analyzed an outbreak of coronavirus disease 2019 (COVID-19) that occurred in a high-rise building in China. Our objective was to investigate the plausibility of aerosol transmission of SARS-CoV-2 by testing relevant environmental variables and measuring the dispersion of a tracer gas in the drainage system of the building. The outbreak involved 7 infected families, of which 6 were from vertically aligned flats on different floors. Environmenìtal data revealed that 3 families' bathrooms were contaminated by SARS-CoV-2. In our tracer experiment, we injected tracer gas (CO2) into the dry floor drains and into water-filled toilets in the index case' s bathroom. Our findings showed that the gas could travel through vertical pipes by the dry floor drains, but not through the water of the toilets. This indicates that dry floor drains might facilitate the transmission of viral aerosols through the sewage system. On the basis of circumstantial evidence, long-range aerosol transmission may have contributed to the community outbreak of COVID-19 in this high-rise building. The vertical transmission of diseases through aerosols in high-rise buildings demands urgent attention.
Collapse
Affiliation(s)
- Xiaoman Jiang
- Chengdu Workstation for Emerging Infectious Disease Control and Prevention, Chinese Academy of Medical Science, Chengdu, China
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Chenlu Zhao
- Chengdu Workstation for Emerging Infectious Disease Control and Prevention, Chinese Academy of Medical Science, Chengdu, China
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Yuezhu Chen
- Chengdu Workstation for Emerging Infectious Disease Control and Prevention, Chinese Academy of Medical Science, Chengdu, China
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Xufang Gao
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Qinlong Zhang
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Zhenhua Chen
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Changxiong Li
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Xiaoyan Zhao
- Chenghua Center for Disease Control and Prevention, Chengdu, China
| | - Zhijian Liu
- Chenghua Center for Disease Control and Prevention, Chengdu, China
| | - Weiwei Huang
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Wenjun Xie
- Chengdu Workstation for Emerging Infectious Disease Control and Prevention, Chinese Academy of Medical Science, Chengdu, China
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Yong Yue
- Chengdu Workstation for Emerging Infectious Disease Control and Prevention, Chinese Academy of Medical Science, Chengdu, China
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| |
Collapse
|
6
|
Siebler L, Rathje T, Calandri M, Stergiaropoulos K, Donker T, Richter B, Spahn C, Nusseck M. A coupled experimental and statistical approach for an assessment of SARS-CoV-2 infection risk at indoor event locations. BMC Public Health 2023; 23:1394. [PMID: 37474924 PMCID: PMC10357618 DOI: 10.1186/s12889-023-16154-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 06/19/2023] [Indexed: 07/22/2023] Open
Abstract
Indoor event locations are particularly affected by the SARS-CoV-2 pandemic. At large venues, only incomplete risk assessments exist, whereby no suitable measures can be derived. In this study, a physical and data-driven statistical model for a comprehensive infection risk assessment has been developed. At venues displacement ventilation concepts are often implemented. Here simplified theoretical assumptions fail for the prediction of relevant airflows for airborne transmission processes. Thus, with locally resolving trace gas measurements infection risks are computed more detailed. Coupled with epidemiological data such as incidences, vaccination rates, test sensitivities, and audience characteristics such as masks and age distribution, predictions of new infections (mean), situational R-values (mean), and individual risks on- and off-seat can be achieved for the first time. Using the Stuttgart State Opera as an example, the functioning of the model and its plausibility are tested and a sensitivity analysis is performed with regard to masks and tests. Besides a reference scenario on 2022-11-29, a maximum safety scenario with an obligation of FFP2 masks and rapid antigen tests as well as a minimum safety scenario without masks and tests are investigated. For these scenarios the new infections (mean) are 10.6, 0.25 and 13.0, respectively. The situational R-values (mean) - number of new infections caused by a single infectious person in a certain situation - are 2.75, 0.32 and 3.39, respectively. Besides these results a clustered consideration divided by age, masks and whether infections occur on-seat or off-seat are presented. In conclusion this provides an instrument that can enable policymakers and operators to take appropriate measures to control pandemics despite ongoing mass gathering events.
Collapse
Affiliation(s)
- Lukas Siebler
- Institute for Building Energetics, Thermotechnology and Energy Storage (IGTE), University of Stuttgart, Pfaffenwaldring 35, Stuttgart, 70569, Baden-Württemberg, Germany.
| | - Torben Rathje
- Institute for Building Energetics, Thermotechnology and Energy Storage (IGTE), University of Stuttgart, Pfaffenwaldring 35, Stuttgart, 70569, Baden-Württemberg, Germany
| | - Maurizio Calandri
- Institute for Building Energetics, Thermotechnology and Energy Storage (IGTE), University of Stuttgart, Pfaffenwaldring 35, Stuttgart, 70569, Baden-Württemberg, Germany
| | - Konstantinos Stergiaropoulos
- Institute for Building Energetics, Thermotechnology and Energy Storage (IGTE), University of Stuttgart, Pfaffenwaldring 35, Stuttgart, 70569, Baden-Württemberg, Germany
| | - Tjibbe Donker
- Institute for Infection Prevention and Hospital Epidemiology, University Medical Center Freiburg, Breisacher Straße 115 B, Freiburg, 79106, Baden-Württemberg, Germany
| | - Bernhard Richter
- Freiburg Institute for Musicians' Medicine, University of Music Freiburg, University Medical Center Freiburg, Medical Faculty of the Albert-Ludwigs-University Freiburg, Freiburg Center for Research and Teaching in Music, Germany, Elsässer Straße 2m, Freiburg, 79110, Baden-Württemberg, Germany
| | - Claudia Spahn
- Freiburg Institute for Musicians' Medicine, University of Music Freiburg, University Medical Center Freiburg, Medical Faculty of the Albert-Ludwigs-University Freiburg, Freiburg Center for Research and Teaching in Music, Germany, Elsässer Straße 2m, Freiburg, 79110, Baden-Württemberg, Germany
| | - Manfred Nusseck
- Freiburg Institute for Musicians' Medicine, University of Music Freiburg, University Medical Center Freiburg, Medical Faculty of the Albert-Ludwigs-University Freiburg, Freiburg Center for Research and Teaching in Music, Germany, Elsässer Straße 2m, Freiburg, 79110, Baden-Württemberg, Germany
| |
Collapse
|
7
|
Wu J, Weng W, Fu M, Li Y. Numerical study of transient indoor airflow and virus-laden droplet dispersion: Impact of interactive human movement. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 869:161750. [PMID: 36690100 DOI: 10.1016/j.scitotenv.2023.161750] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/29/2022] [Accepted: 01/17/2023] [Indexed: 06/17/2023]
Abstract
Human movement affects indoor airflow and the airborne transmission of respiratory infectious diseases, which has attracted scholars. However, the interactive airflow between moving and stationary people has yet to be studied in detail. This study used the numerical method validated by experimental data to explore the transient indoor airflow and virus-laden droplet dispersion in scenes with interactive human movement. Human-shaped numerical models and the dynamic mesh method were adopted to realize human movement in scenes with different lateral distances (0.2-1.2 m) between a moving person and stationary (standing/sitting) persons. The interactive human movement obviously impacts other persons' respiratory airflow, and the lateral fusion ranged about 0.6 m. The interactive human movement strengthens the indoor airflow convection, and some exhaled virus-laden droplets were carried into wake flow and enhanced long-range airborne transmission. The impact of interactive human movement on sitting patients' exhalation airflow seems more evident than on standing patients. The impact might last over 2 min after movement stopped, and people in the affected area might be at a higher exposure. The results can provide a reference for epidemic control in indoor environments.
Collapse
Affiliation(s)
- Jialin Wu
- Institute of Public Safety Research, Department of Engineering Physics, Tsinghua University, Beijing 100084, PR China; Beijing Key Laboratory of City Integrated Emergency Response Science, Tsinghua University, Beijing 100084, PR China
| | - Wenguo Weng
- Institute of Public Safety Research, Department of Engineering Physics, Tsinghua University, Beijing 100084, PR China; Beijing Key Laboratory of City Integrated Emergency Response Science, Tsinghua University, Beijing 100084, PR China.
| | - Ming Fu
- Hefei Institute for Public Safety Research, Tsinghua University, Hefei, Anhui Province 230601, PR China; Anhui Province Key Laboratory of Human Safety, Hefei, Anhui Province 230601, PR China
| | - Yayun Li
- Hefei Institute for Public Safety Research, Tsinghua University, Hefei, Anhui Province 230601, PR China; Anhui Province Key Laboratory of Human Safety, Hefei, Anhui Province 230601, PR China
| |
Collapse
|
8
|
Tsang TW, Mui KW, Wong LT, Law KY, Shek KW. A Novel IoT-Enabled Wireless Sensor Grid for Spatial and Temporal Evaluation of Tracer Gas Dispersion. SENSORS (BASEL, SWITZERLAND) 2023; 23:3920. [PMID: 37112265 PMCID: PMC10145748 DOI: 10.3390/s23083920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 04/07/2023] [Accepted: 04/11/2023] [Indexed: 06/19/2023]
Abstract
Current IoT applications in indoor air focus mainly on general monitoring. This study proposed a novel IoT application to evaluate airflow patterns and ventilation performance using tracer gas. The tracer gas is a surrogate for small-size particles and bioaerosols and is used in dispersion and ventilation studies. Prevalent commercial tracer-gas-measuring instruments, although highly accurate, are relatively expensive, have a long sampling cycle, and are limited in the number of sampling points. To enhance the spatial and temporal understanding of tracer gas dispersion under the influence of ventilation, a novel application of an IoT-enabled, wireless R134a sensing network using commercially available small sensors was proposed. The system has a detection range of 5-100 ppm and a sampling cycle of 10 s. Using Wi-Fi communication, the measurement data are transmitted to and stored in a cloud database for remote, real-time analysis. The novel system provides a quick response, detailed spatial and temporal profiles of the tracer gas level, and a comparable air change rate analysis. With multiple units deployed as a wireless sensing network, the system can be applied as an affordable alternative to traditional tracer gas systems to identify the dispersion pathway of the tracer gas and the general airflow direction.
Collapse
Affiliation(s)
- Tsz-Wun Tsang
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Kwok-Wai Mui
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Ling-Tim Wong
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Kwok-Yung Law
- Department of Mechanical Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Ka-Wing Shek
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
9
|
Vita G, Woolf D, Avery-Hickmott T, Rowsell R. A CFD-based framework to assess airborne infection risk in buildings. BUILDING AND ENVIRONMENT 2023; 233:110099. [PMID: 36815961 PMCID: PMC9925846 DOI: 10.1016/j.buildenv.2023.110099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 01/31/2023] [Accepted: 02/12/2023] [Indexed: 06/18/2023]
Abstract
The COVID-19 pandemic has prompted huge efforts to further the scientific knowledge of indoor ventilation and its relationship to airborne infection risk. Exhaled infectious aerosols are spread and inhaled as a result of room airflow characteristics. Many calculation methods and assertions on risk assume 'well-mixed' flow conditions. However, ventilation in buildings is complex and often not showing well-mixed conditions. Ventilation guidance is typically based on the provision of generic minimum ventilation flow rates for a given space, irrespective of the effectiveness in the delivery of the supply air. Furthermore, the airflow might be heavily affected by the season, the HVAC ventilation, or the opening of windows, which would potentially generate draughts and non-uniform conditions. As a result, fresh air concentration would be variable depending upon a susceptible receptor's position in a room and, therefore, associated airborne infection risk. A computational fluid dynamics (CFD) and dynamic thermal modelling (DTM) framework is proposed to assess the influence of internal airflow characteristics on airborne infection risk. A simple metric is proposed, the hourly airborne infection rate (HAI) which can easily help designers to stress-test the ventilation within a building under several conditions. A case study is presented, and the results clearly demonstrate the importance of understanding detailed indoor airflow characteristics and associated concentration patterns in order to provide detailed design guidance, e.g. occupancy, supply air diffusers and furniture layouts, to reduce airborne infection risk.
Collapse
Affiliation(s)
- Giulio Vita
- Wirth Research Ltd, Charlotte Avenue, Bicester, OX27 8BL, United Kingdom
- University of Birmingham School of Engineering Edgbaston, Birmingham, B15 2TT, United Kingdom
| | - Darren Woolf
- Wirth Research Ltd, Charlotte Avenue, Bicester, OX27 8BL, United Kingdom
| | | | - Rob Rowsell
- Wirth Research Ltd, Charlotte Avenue, Bicester, OX27 8BL, United Kingdom
| |
Collapse
|
10
|
Qin C, Zhang SZ, Li ZT, Wen CY, Lu WZ. Transmission mitigation of COVID-19: Exhaled contaminants removal and energy saving in densely occupied space by impinging jet ventilation. BUILDING AND ENVIRONMENT 2023; 232:110066. [PMID: 36779167 PMCID: PMC9894780 DOI: 10.1016/j.buildenv.2023.110066] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 01/28/2023] [Accepted: 01/31/2023] [Indexed: 05/31/2023]
Abstract
The pandemic of COVID-19 and its transmission ability raise much attention to ventilation design as indoor-transmission outstrips outdoor-transmission. Impinging jet ventilation (IJV) systems might be promising to ventilate densely occupied large spaces due to their high jet momentum. However, their performances in densely occupied spaces have rarely been explored. This study proposes a modified IJV system and evaluates its performance numerically in a densely occupied classroom mockup. A new assessment formula is also proposed to evaluate the nonuniformity of target species CO2. The infector is assumed as the manikin with the lowest tracer gas concentration in the head region. The main results include: a) Indoor air quality (IAQ) in the classroom is improved significantly compared with a mixing ventilation system, i.e., averaged CO2 in the occupied zone (OZ) is reduced from 1287 ppm to 1078 ppm, the OZ-averaged mean age of air is reduced from 439 s to 177 s; b) The mean infection probability is reduced from 0.047% to 0.027% with an infector, and from 0.035% to 0.024% with another infector; c) Cooling coil load is reduced by around 21.0%; d) Overall evaluation indices meet the requirements for comfortable environments, i.e., the temperature difference between head and ankle is within 3 °C and the OZ-averaged predictive mean vote is in the range of -0.5 - 0.5; e) Thermal comfort level and uniformity are decreased, e.g., overcooling near diffuser at ankle level. Summarily, the target system effectively improves IAQ, reduces exhaled-contaminant concentration in head regions, and saves energy as well.
Collapse
Affiliation(s)
- Chao Qin
- Department of Architecture and Civil Engineering, City University of Hong Kong, Hong Kong Special Administrative Region
| | - Shu-Zhen Zhang
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region
| | - Zheng-Tong Li
- Department of Aeronautical and Aviation Engineering, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region
| | - Chih-Yung Wen
- Department of Aeronautical and Aviation Engineering, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region
| | - Wei-Zhen Lu
- Department of Architecture and Civil Engineering, City University of Hong Kong, Hong Kong Special Administrative Region
| |
Collapse
|
11
|
Castellini JE, Faulkner CA, Zuo W, Sohn MD. Quantifying spatiotemporal variability in occupant exposure to an indoor airborne contaminant with an uncertain source location. BUILDING SIMULATION 2023; 16:889-913. [PMID: 37192915 PMCID: PMC9986047 DOI: 10.1007/s12273-022-0971-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 11/10/2022] [Accepted: 11/28/2022] [Indexed: 05/18/2023]
Abstract
Well-mixed zone models are often employed to compute indoor air quality and occupant exposures. While effective, a potential downside to assuming instantaneous, perfect mixing is underpredicting exposures to high intermittent concentrations within a room. When such cases are of concern, more spatially resolved models, like computational-fluid dynamics methods, are used for some or all of the zones. But, these models have higher computational costs and require more input information. A preferred compromise would be to continue with a multi-zone modeling approach for all rooms, but with a better assessment of the spatial variability within a room. To do so, we present a quantitative method for estimating a room's spatiotemporal variability, based on influential room parameters. Our proposed method disaggregates variability into the variability in a room's average concentration, and the spatial variability within the room relative to that average. This enables a detailed assessment of how variability in particular room parameters impacts the uncertain occupant exposures. To demonstrate the utility of this method, we simulate contaminant dispersion for a variety of possible source locations. We compute breathing-zone exposure during the releasing (source is active) and decaying (source is removed) periods. Using CFD methods, we found after a 30 minutes release the average standard deviation in the spatial distribution of exposure was approximately 28% of the source average exposure, whereas variability in the different average exposures was lower, only 10% of the total average. We also find that although uncertainty in the source location leads to variability in the average magnitude of transient exposure, it does not have a particularly large influence on the spatial distribution during the decaying period, or on the average contaminant removal rate. By systematically characterizing a room's average concentration, its variability, and the spatial variability within the room important insights can be gained as to how much uncertainty is introduced into occupant exposure predictions by assuming a uniform in-room contaminant concentration. We discuss how the results of these characterizations can improve our understanding of the uncertainty in occupant exposures relative to well-mixed models.
Collapse
Affiliation(s)
- John E. Castellini
- Department of Mechanical Engineering, University of Colorado Boulder, UCB 427, Boulder, CO 80309 USA
| | - Cary A. Faulkner
- Department of Mechanical Engineering, University of Colorado Boulder, UCB 427, Boulder, CO 80309 USA
| | - Wangda Zuo
- Department Architectural Engineering, The Pennsylvania State University, University Park, PA 16802 USA
- National Renewable Energy National Laboratory, Golden, CO 80401 USA
| | - Michael D. Sohn
- Energy Analysis and Environmental Impacts Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 USA
| |
Collapse
|
12
|
Research on the cross-contamination in the confined conference room with the radiant floor heating system integrated with the down-supply ventilation. Heliyon 2023; 9:e14389. [PMID: 36925522 PMCID: PMC10010993 DOI: 10.1016/j.heliyon.2023.e14389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 03/01/2023] [Accepted: 03/02/2023] [Indexed: 03/11/2023] Open
Abstract
The performance of a confined conference room under radiant heat floor combined with down-supply ventilation (RFDS) is investigated. The purpose of the study is to reveal the mechanism of indoor contaminants transmission from infected person and to protect the occupants. The exhaled contaminant dispersion was simulated using a CFD model and experimentally validated in an office with the down-supply ventilation (DS). The effects of radiant floor (RF) combined with down-supply ventilation on airflow and contaminant distribution in the room was evaluated with regard to different RF temperatures and inlet velocities. The influence of downdraft from the envelope on the airflow pattern of the room is also discussed. It is proved that the exposure risk of pollutants can be reduced by strengthening the insulation of the envelope. The simulation results showed that the proposed RFDS system could significantly reduce the level of exposure to contaminants in the breathing zone (BZ) of occupants. In this research case, the RFDS reduced the average exposure rates by more than 50% relative to the case with the only down-supply warm air heating. Furthermore, With improved envelope insulation, the probability of infection can be reduced by more than 80% only by avoiding a simultaneous inlet velocity of 0.3 m/s at RF temperatures no less than 27 °C. The results suggested an improved fresh air heating mode for passive ultra-low energy consumption buildings with good thermal insulation and air tightness.
Collapse
|
13
|
Zhang T(T, Yao L, Gao Z, Wang F. Particle exposure risk to a lavatory user after flushing a squat toilet. Sci Rep 2022; 12:21088. [PMID: 36473899 PMCID: PMC9726816 DOI: 10.1038/s41598-022-25106-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 11/24/2022] [Indexed: 12/12/2022] Open
Abstract
Squat toilets are widely used in developing countries due to local customs and low costs. The flushing of a squat toilet can entrain strong airflow and produce aerosols. This investigation constructed a lavatory mock-up with a squat toilet. The flushing-induced airflow was both visualized and quantitatively measured by particle image velocimetry. The maximum height of the impacted airflow was identified by an ultrasonic anemometer. For inference of the particle emission rate, the toilet bowl was covered by an enclosed box for particle concentration measurement. The risks from skin contact of the deposited particles on the flushing button and the door handle and the possible inhalation of the released aerosols were evaluated. The results revealed that flushing a squat toilet can drive toilet plume to rise up to 0.9 m above the toilet bowl. A single flushing process can produce 0.29 million particles with diameters greater than 0.3 μm, among which 90% of the particles are submicron-sized. The flushing may cause particles to deposit on the flushing button and lavatory door handle as well as inhalation exposure even remaining in the lavatory for half a minute after flushing, especially for those lavatory users whose respiratory zones are below 1.0 m.
Collapse
Affiliation(s)
- Tengfei (Tim) Zhang
- grid.30055.330000 0000 9247 7930School of Civil Engineering, Dalian University of Technology, Dalian, China
| | - Lifang Yao
- grid.30055.330000 0000 9247 7930School of Civil Engineering, Dalian University of Technology, Dalian, China
| | - Zilong Gao
- grid.30055.330000 0000 9247 7930School of Civil Engineering, Dalian University of Technology, Dalian, China
| | - Feng Wang
- grid.33763.320000 0004 1761 2484Tianjin Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China
| |
Collapse
|
14
|
Ren C, Haghighat F, Feng Z, Kumar P, Cao SJ. Impact of ionizers on prevention of airborne infection in classroom. BUILDING SIMULATION 2022; 16:749-764. [PMID: 36474607 PMCID: PMC9716175 DOI: 10.1007/s12273-022-0959-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 10/12/2022] [Accepted: 10/31/2022] [Indexed: 06/17/2023]
Abstract
UNLABELLED Infectious diseases (e.g., coronavirus disease 2019) dramatically impact human life, economy and social development. Exploring the low-cost and energy-saving approaches is essential in removing infectious virus particles from indoors, such as in classrooms. The application of air purification devices, such as negative ion generators (ionizers), gains popularity because of the favorable removal capacity for particles and the low operation cost. However, small and portable ionizers have potential disadvantages in the removal efficiency owing to the limited horizontal diffusion of negative ions. This study aims to investigate the layout strategy (number and location) of ionizers based on the energy-efficient natural ventilation in the classroom to improve removal efficiency (negative ions to particles) and decrease infection risk. Three infected students were considered in the classroom. The simulations of negative ion and particle concentrations were performed and validated by the experiment. Results showed that as the number of ionizers was 4 and 5, the removal performance was largely improved by combining ionizer with natural ventilation. Compared with the scenario without an ionizer, the scenario with 5 ionizers largely increased the average removal efficiency from around 20% to 85% and decreased the average infection risk by 23%. The setup with 5 ionizers placed upstream of the classroom was determined as the optimal layout strategy, particularly when the location and number of the infected students were unknown. This work can provide a guideline for applying ionizers to public buildings when natural ventilation is used. ELECTRONIC SUPPLEMENTARY MATERIAL ESM the Appendix is available in the online version of this article at 10.1007/s12273-022-0959-z.
Collapse
Affiliation(s)
- Chen Ren
- School of Architecture, Southeast University, 2 Sipailou, Nanjing, 210096 China
| | - Fariborz Haghighat
- School of Architecture, Southeast University, 2 Sipailou, Nanjing, 210096 China
- Energy and Environment Group, Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, H3G 1M8 Canada
| | - Zhuangbo Feng
- School of Architecture, Southeast University, 2 Sipailou, Nanjing, 210096 China
| | - Prashant Kumar
- School of Architecture, Southeast University, 2 Sipailou, Nanjing, 210096 China
- Global Centre for Clean Air Research (GCARE), School of Sustainability, Civil & Environmental Engineering, Faculty of Engineering & Physical Sciences, University of Surrey, Guildford, Surrey, GU2 7XH UK
- Institute for Sustainability, University of Surrey, Guildford, Surrey, GU2 7XH UK
| | - Shi-Jie Cao
- School of Architecture, Southeast University, 2 Sipailou, Nanjing, 210096 China
- Global Centre for Clean Air Research (GCARE), School of Sustainability, Civil & Environmental Engineering, Faculty of Engineering & Physical Sciences, University of Surrey, Guildford, Surrey, GU2 7XH UK
| |
Collapse
|
15
|
Aganovic A, Cao G, Kurnitski J, Melikov A, Wargocki P. Zonal modeling of air distribution impact on the long-range airborne transmission risk of SARS-CoV-2. APPLIED MATHEMATICAL MODELLING 2022; 112:800-821. [PMID: 36060304 PMCID: PMC9420246 DOI: 10.1016/j.apm.2022.08.027] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 08/15/2022] [Accepted: 08/25/2022] [Indexed: 05/10/2023]
Abstract
A widely used analytical model to quantitatively assess airborne infection risk is the Wells-Riley model which is limited to complete air mixing in a single zone. However, this assumption tends not to be feasible (or reality) for many situations. This study aimed to extend the Wells-Riley model so that the infection risk can be calculated in spaces where complete mixing is not present. Some more advanced ventilation concepts create either two horizontally divided air zones in spaces as displacement ventilation or the space may be divided into two vertical zones by downward plane jet as in protective-zone ventilation systems. This is done by evaluating the time-dependent distribution of infectious quanta in each zone and by solving the coupled system of differential equations based on the zonal quanta concentrations. This model introduces a novel approach by estimating the interzonal mixing factor based on previous experimental data for three types of ventilation systems: incomplete mixing ventilation, displacement ventilation, and protective zone ventilation. The modeling approach is applied to a room with one infected and one susceptible person present. The results show that using the Wells-Riley model based on the assumption of completely air mixing may considerably overestimate or underestimate the long-range airborne infection risk in rooms where air distribution is different than complete mixing, such as displacement ventilation, protected zone ventilation, warm air supplied from the ceiling, etc. Therefore, in spaces with non-uniform air distribution, a zonal modeling approach should be preferred in analytical models compared to the conventional single-zone Wells-Riley models when assessing long-range airborne transmission risk of infectious respiratory diseases.
Collapse
Affiliation(s)
- Amar Aganovic
- Department of Automation and Process Engineering, UiT The Arctic University of Norway, Postboks 6050 Langnes, Tromsø 9037, Norway
| | - Guangyu Cao
- Department of Energy and Process Engineering, Norwegian University of Science and Technology - NTNU, Trondheim, Norway
| | - Jarek Kurnitski
- REHVA Technology and Research Committee, Tallinn University of Technology, Tallinn, Estonia
| | - Arsen Melikov
- Department of Civil Engineering, Technical University of Denmark, Copenhagen, Denmark
| | - Pawel Wargocki
- Department of Civil Engineering, Technical University of Denmark, Copenhagen, Denmark
| |
Collapse
|
16
|
Cheung T, Li J, Goh J, Sekhar C, Cheong D, Tham KW. Evaluation of aerosol transmission risk during home quarantine under different operating scenarios: A pilot study. BUILDING AND ENVIRONMENT 2022; 225:109640. [PMID: 36210963 PMCID: PMC9528801 DOI: 10.1016/j.buildenv.2022.109640] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 09/22/2022] [Accepted: 09/24/2022] [Indexed: 06/09/2023]
Abstract
SARS-CoV-2 has been recognized to be airborne transmissible. With the large number of reported positive cases in the community, home quarantine is recommended for the infectors who are not severely ill. However, the risks of household aerosol transmission associated with the quarantine room operating methods are under-explored. We used tracer gas technique to simulate the exhaled virus laden aerosols from a patient under home quarantine situation inside a residential testbed. The Sulphur hexafluoride (SF6) concentration was measured both inside and outside the quarantine room under different operating settings including, air-conditioning and natural ventilation, presence of an exhaust fan, and the air movement generated by ceiling or pedestal fan. We calculated the outside-to-inside SF6 concentration to indicate potential exposure of occupants in the same household. In-room concentration with air-conditioning was 4 times higher than in natural ventilation settings. Exhaust fan operation substantially reduced in-room SF6 concentration and leakage rate in most of the ventilation scenarios, except for natural ventilation setting with ceiling fan. The exception is attributable to the different airflow patterns between ceiling fan (recirculates air vertically) and pedestal fan (moves air horizontally). These airflow variations also led to differences in SF6 concentration at two sampling heights (0.1 m and 1.7 m) and SF6 leakage rates when the quarantine room door was opened momentarily. Use of natural ventilation rather than air-conditioning, and operating exhaust fan when using air-conditioning are recommended to lower exposure risk for home quarantine. A more holistic experiment will be conducted to address the limitations reflected in this study.
Collapse
Affiliation(s)
- Toby Cheung
- Department of the Built Environment, National University of Singapore, Singapore
| | - Jiayu Li
- Berkeley Education Alliance for Research in Singapore (BEARS), Singapore
| | - Jiamin Goh
- Department of the Built Environment, National University of Singapore, Singapore
| | - Chandra Sekhar
- Department of the Built Environment, National University of Singapore, Singapore
| | - David Cheong
- Department of the Built Environment, National University of Singapore, Singapore
| | - Kwok Wai Tham
- Department of the Built Environment, National University of Singapore, Singapore
| |
Collapse
|
17
|
Sussman RA, Golberstein E, Polosa R. Analytic modeling and risk assessment of aerial transmission of SARS-CoV-2 virus through vaping expirations in shared micro-environments. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:83020-83044. [PMID: 35754079 PMCID: PMC9244239 DOI: 10.1007/s11356-022-20499-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 04/22/2022] [Indexed: 06/15/2023]
Abstract
It is well known that airborne transmission of COVID-19 in indoor spaces occurs through various respiratory activities: breathing, vocalizing, coughing, and sneezing. However, there is a complete lack of knowledge of its possible transmission through exhalations of e-cigarette aerosol (ECA), which is also a respiratory activity. E-cigarettes have become widely popular among smokers seeking a much safer way of nicotine consumption than smoking. Due to restrictive lockdown measures taken during the COVID-19 pandemic, many smokers and vapers (e-cigarette users) were confined to shared indoor spaces, making it necessary to assess the risk of SARS-CoV-2 virus aerial transmission through their exhalations. We summarize inferred knowledge of respiratory particles emission and transport through ECA, as well as a theoretical framework for explaining the visibility of exhaled ECA, which has safety implications and is absent in other respiratory activities (apart from smoking). We also summarize and briefly discuss the effects of new SARS-CoV-2 variants, vaccination rates, and environmental factors that may influence the spread of COVID-19. To estimate the risk of SARS-CoV-2 virus aerial transmission associated with vaping exhalations, we adapt a theoretical risk model that has been used to analyze the risks associated with other respiratory activities in shared indoor spaces. We consider home and restaurant scenarios, with natural and mechanical ventilation, with occupants wearing and not wearing face masks. We consider as "control case" or baseline risk scenario an indoor space (home and restaurant) where respiratory droplets and droplet nuclei are uniformly distributed and aerial contagion risk might originate exclusively from occupants exclusively rest breathing, assuming this to be the only (unavoidable) respiratory activity they all carry on. If an infected occupant uses an e-cigarette in a home or restaurant scenarios, bystanders not wearing face masks exposed to the resulting ECA expirations face a [Formula: see text] increase of risk of contagion with respect the control case. This relative added risk with respect to the control case becomes [Formula: see text] for high-intensity vaping, [Formula: see text], and over [Formula: see text] for speaking for various periods or coughing (all without vaping). Infectious emissions are significantly modified by mechanical ventilation, face mask usage, vaccination, and environmental factors, but given the lack of empiric evidence, we assume as a working hypothesis that all basic parameters of respiratory activities are equally (or roughly equally) affected by these factors. Hence, the relative risk percentages with respect to the control state should remain roughly the same under a wide range of varying conditions. By avoiding direct exposure to the visible exhaled vaping jet, wearers of commonly used face masks are well protected from respiratory droplets and droplet nuclei directly emitted by mask-less vapers. Compared to the control case of an already existing (unavoidable) risk from continuous breathing, vaping emissions in shared indoor spaces pose just a negligible additional risk of COVID-19 contagion. We consider that it is not necessary to take additional preventive measures beyond those already prescribed (1.5 m separation and wearing face masks) in order to protect bystanders from this contagion.
Collapse
Affiliation(s)
- Roberto A Sussman
- Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, 04510, Mexico City, Mexico
| | - Eliana Golberstein
- Myriad Pharmaceuticals Limited, Unit 3, 36 Greenpark Rd, Penrose, 1061, Auckland, New Zealand
| | - Riccardo Polosa
- Center of Excellence for the Acceleration of HArm Reduction (CoEHAR), University of Catania, Catania, Italy.
| |
Collapse
|
18
|
Siebler L, Calandri M, Rathje T, Stergiaropoulos K. Experimental Methods of Investigating Airborne Indoor Virus-Transmissions Adapted to Several Ventilation Measures. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:11300. [PMID: 36141572 PMCID: PMC9517214 DOI: 10.3390/ijerph191811300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 08/31/2022] [Accepted: 09/03/2022] [Indexed: 06/16/2023]
Abstract
This study introduces a principle that unifies two experimental methods for evaluating airborne indoor virus-transmissions adapted to several ventilation measures. A first-time comparison of mechanical/natural ventilation and air purification with regard to infection risks is enabled. Effortful computational fluid dynamics demand detailed boundary conditions for accurate calculations of indoor airflows, which are often unknown. Hence, a suitable, simple and generalized experimental set up for identifying the spatial and temporal infection risk for different ventilation measures is more qualified even with unknown boundary conditions. A trace gas method is suitable for mechanical and natural ventilation with outdoor air exchange. For an accurate assessment of air purifiers based on filtration, a surrogate particle method is appropriate. The release of a controlled rate of either trace gas or particles simulates an infectious person releasing virus material. Surrounding substance concentration measurements identify the neighborhood exposure. One key aspect of the study is to prove that the requirement of concordant results of both methods is fulfilled. This is the only way to ensure that the comparison of different ventilation measures described above is reliable. Two examples (a two-person office and a classroom) show how practical both methods are and how the principle is applicable for different types and sizes of rooms.
Collapse
|
19
|
Issakhov A, Omarova P, Borsikbayeva A. Assessment of airborne transmission from coughing processes with thermal plume adjacent to body and radiators on effectiveness of social distancing. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:66808-66840. [PMID: 35508854 DOI: 10.1007/s11356-022-18713-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Accepted: 01/13/2022] [Indexed: 06/14/2023]
Abstract
The new coronavirus disease COVID-19 has caused a worldwide pandemic to be declared in a very short period of time. The complexity of the infection lies in asymptomatic carriers that can inadvertently transmit the virus through airborne droplets. This kind of viral disease can infect the human body with tiny particles that carry various bacteria that are generated by the respiratory system of infected patients. In this study, numerical results are proposed that demonstrate the effect of human body temperature and temperature from radiators in a room on the spread of the smallest droplets and particles in an enclosed space. The numerical model proposed in this work takes into account the sedimentation of particles and droplets under the action of gravitational sedimentation and transport in a closed room during the processes of breathing, sneezing or coughing. Various cases were considered, taking into account normal human breathing, coughing or sneezing, as well as three different values of the rate of emission of particles from the human mouth. The heat plume, which affects the concentration of particles in the breathing zone, spreads the particle up to a distance of 4.29 m in the direction of the air flow. It can also be seen from the results obtained that the presence of radiators strongly affects the propagation of particles of various sizes in a closed room. From the obtained results, it should be noted that in order to recommend the optimal social distance, it is necessary to take into account many factors, especially momentum, gravity, human body temperature, as well as the process of natural convection, which greatly affect the propagation of particles in a closed room. The conclusions drawn from the results of this work show that, given the environmental conditions, the social distance of 2 m may not be enough.
Collapse
Affiliation(s)
- Alibek Issakhov
- Al-Farabi, Kazakh National University, Almaty, Republic of Kazakhstan.
- Kazakh British Technical University, Almaty, Republic of Kazakhstan.
- International Information Technology University, Almaty, Republic of Kazakhstan.
| | - Perizat Omarova
- Al-Farabi, Kazakh National University, Almaty, Republic of Kazakhstan
| | | |
Collapse
|
20
|
Ferrari S, Blázquez T, Cardelli R, Puglisi G, Suárez R, Mazzarella L. Ventilation strategies to reduce airborne transmission of viruses in classrooms: A systematic review of scientific literature. BUILDING AND ENVIRONMENT 2022; 222:109366. [PMID: 35818484 PMCID: PMC9259197 DOI: 10.1016/j.buildenv.2022.109366] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 06/20/2022] [Accepted: 07/02/2022] [Indexed: 06/15/2023]
Abstract
The recent pandemic due to SARS-CoV-2 has brought to light the need for strategies to mitigate contagion between human beings. Apart from hygiene measures and social distancing, air ventilation highly prevents airborne transmission within enclosed spaces. Among others, educational environments become critical in strategic planning to control the spread of pathogens and viruses amongst the population, mainly in cold conditions. In the event of a virus outbreak - such as COVID or influenza - many school classrooms still lack the means to guarantee secure and healthy environments. The present review examines school contexts that implement air ventilation strategies to reduce the risk of contagion between students. The analysed articles present past experiences that use either natural or mechanical systems assessed through mathematical models, numerical models, or full-scale experiments. For naturally ventilated classrooms, the studies highlight the importance of the architectural design of educational spaces and propose strategies for aeration control such as CO2-based control and risk-infection control. When it comes to implementing mechanical ventilation in classrooms, different systems with different airflow patterns are assessed based on their ability to remove airborne pathogens considering parameters like the age of air and the generation of airflow streamlines. Moreover, studies report that programmed mechanical ventilation systems can reduce risk-infection during pandemic events. In addition to providing a systematic picture of scientific studies in the field, the findings of this review can be a valuable reference for school administrators and policymakers to implement the best strategies in their classroom settings towards reducing infection risks.
Collapse
Affiliation(s)
- S Ferrari
- Dept. of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Milano, Italy
| | - T Blázquez
- Dept. of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Milano, Italy
| | - R Cardelli
- Dept. of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Milano, Italy
| | - G Puglisi
- Dept. of Energy Efficiency Department, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy
| | - R Suárez
- Instituto Universitario de Arquitectura y Ciencias de la Construcción, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, Sevilla, Spain
| | - L Mazzarella
- Dept. of Energy, Politecnico di Milano, Milano, Italy
| |
Collapse
|
21
|
Wang J, Tang H, Wang J, Zhong Z. An agent-based study on the airborne transmission risk of infectious disease in a fever clinic during COVID-19 pandemic. BUILDING AND ENVIRONMENT 2022; 218:109118. [PMID: 35474851 PMCID: PMC9023374 DOI: 10.1016/j.buildenv.2022.109118] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 04/16/2022] [Accepted: 04/18/2022] [Indexed: 06/14/2023]
Abstract
Prevention of nosocomial infections is particularly important for the control of COVID-19 pandemic. We conducted a field study and performed extensive numerical simulations of infection transmission in a fever clinic during pandemic through an agent-based model with pedestrian dynamic and an infection transmission model. Furthermore, we evaluated the cross-infection risk of the patients influenced by the patient inject flow, medical service capability and plane layout. The service capability of fever clinic is determined by the least efficient medical session. When patient inject flow exceeded the service capability, the average dwell time, contact time, exposure dose, and risk of infection of patients all increased dramatically. With the patient inject flow exceeding the service capability, the growth rate of the contact time between patients and the cross-infection risk increased by 11.5-fold and 29.5-fold, respectively. The plane layout of the fever clinic affected the exposure dose and risk of infection. The waiting areas in the fever clinic had the highest risk, where the cumulative exposure dose of virus occupied up to 66.5% of the total. Our research will help to evaluate the biosafety of hospital buildings used for the diagnosis and treatment of infectious diseases.
Collapse
Affiliation(s)
- Junjie Wang
- School of Architecture and Urban Planning, Shenzhen University, Shenzhen, 518060, China
| | - Haida Tang
- School of Architecture and Urban Planning, Shenzhen University, Shenzhen, 518060, China
| | - Jingwei Wang
- School of Architecture, Southeast University, Nanjing, 210000, China
| | - Zhitao Zhong
- School of Architecture, Southeast University, Nanjing, 210000, China
| |
Collapse
|
22
|
Tang H, Pan Z, Li C. Tempo-spatial infection risk assessment of airborne virus via CO 2 concentration field monitoring in built environment. BUILDING AND ENVIRONMENT 2022; 217:109067. [PMID: 35464750 PMCID: PMC9013429 DOI: 10.1016/j.buildenv.2022.109067] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 03/10/2022] [Accepted: 04/03/2022] [Indexed: 05/14/2023]
Abstract
The aerosol transmission was academically recognized as a possible transmission route of Coronavirus disease 2019 (COVID-19). We established an approach to assess the indoor tempo-spatial airborne-disease infection risks through aerosol transmission via real-time CO2 field measurement and occupancy monitoring. Compared to former studies, the proposed method can evaluate real-time airborne disease infection risks through aerosol transmission routes. The approach was utilized in a university office. The accumulated infection risk was calculated for three occupants with practical working schedules (from occupancy recording) and one hypothesis occupant with a typical working schedule. COVID-19 was used as an example. Results demonstrated that the individual infection risks diversified with different dwell times and working places in the office. For the three occupants with a practical working schedule, their 3-day accumulated infection risks were respectively 0.050%, 0.035%, 0.027% and 0.041% due to 11.6, 9.0 and 13.8 h exposure with an initial infector percentage of 1%. The results demonstrate that location and dwell time are both important factors influencing the infection risk of certain occupant in built environment, whereas existing literature seldom took these two points into consideration simultaneously. On the contrary, our proposed approach treated the infection risks as place-by-place, time-by-time and person-by-person diversified in the built environment. The risk assessment results can provide early warning for building occupants and contribute to the transmission control of air-borne disease.
Collapse
Affiliation(s)
- Haida Tang
- School of Architecture and Urban Planning, Shenzhen University, Shenzhen, 518060, China
| | - Zhenyu Pan
- School of Architecture and Urban Planning, Shenzhen University, Shenzhen, 518060, China
| | - Chunying Li
- School of Architecture and Urban Planning, Shenzhen University, Shenzhen, 518060, China
| |
Collapse
|
23
|
Wang Q, Lin Z, Niu J, Choi GKY, Fung JCH, Lau AKH, Louie P, Leung KKM, Huang J, Cheng P, Zhao P, Chen W, Zhang S, Fu L, Chan PW, Wong AH, Tse H, Wong SCY, Lai RWM, Hui DS, Yuen KY, Lung DC, Li Y. Spread of SARS-CoV-2 aerosols via two connected drainage stacks in a high-rise housing outbreak of COVID-19. JOURNAL OF HAZARDOUS MATERIALS 2022; 430:128475. [PMID: 35183827 PMCID: PMC8832857 DOI: 10.1016/j.jhazmat.2022.128475] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 02/08/2022] [Accepted: 02/09/2022] [Indexed: 05/07/2023]
Abstract
Vertical transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) along a vertical column of flats has been documented in several outbreaks of coronavirus disease 2019 (COVID-19) in Guangdong and Hong Kong. We describe an outbreak in Luk Chuen House, involving two vertical columns of flats associated with an unusually connected two-stack drainage system, in which nine individuals from seven households were infected. The index case resided in Flat 812 (8th floor, Unit 12), two flats (813, 817) on its opposite side reported one case each (i.e., a horizontal sub-cluster). All other flats with infected residents were vertically associated, forming a vertical sub-cluster. We injected tracer gas (SF6) into drainage stacks via toilet or balcony of Flat 812, monitored gas concentrations in roof vent, toilet, façade, and living room in four of the seven flats with infected residents and four flats with no infected residents. The measured gas concentration distributions agreed with the observed distribution of affected flats. Aerosols leaking into drainage stacks may generate the vertical sub-cluster, whereas airflow across the corridor probably caused the horizontal sub-cluster. Sequencing and phylogenetic analyses also revealed a common point-source. The findings provided additional evidence of probable roles of drainage systems in SARS-CoV-2 transmission.
Collapse
Affiliation(s)
- Qun Wang
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China
| | - Zhang Lin
- Division of Building Science and Technology, City University of Hong Kong, Hong Kong, China
| | - Jianlei Niu
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | | | - Jimmy C H Fung
- Division of Environment & Sustainability, Hong Kong University of Science and Technology, Hong Kong, China
| | - Alexis K H Lau
- Division of Environment & Sustainability, Hong Kong University of Science and Technology, Hong Kong, China
| | - Peter Louie
- Environmental Protection Department, Hong Kong SAR Government, Hong Kong, China
| | - Kenneth K M Leung
- Environmental Protection Department, Hong Kong SAR Government, Hong Kong, China
| | - Jianxiang Huang
- Department of Urban Planning and Design, Faculty of Architecture, The University of Hong Kong, Hong Kong, China
| | - Pan Cheng
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China
| | - Pengcheng Zhao
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China
| | - Wenzhao Chen
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China
| | - Sheng Zhang
- Division of Building Science and Technology, City University of Hong Kong, Hong Kong, China
| | - Liye Fu
- Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - P W Chan
- Hong Kong Observatory, Kowloon, Hong Kong, China
| | - Ann Han Wong
- Department of Microbiology, Prince of Wales Hospital, Hong Kong, China
| | - Herman Tse
- Department of Pathology, Hong Kong Children's Hospital, Hong Kong, China
| | | | | | - David Sc Hui
- Department of Medicine and Therapeutics, Chinese University of Hong Kong, Hong Kong, China
| | - Kwok-Yung Yuen
- Department of Microbiology, The University of Hong Kong, Hong Kong, China
| | - David Christopher Lung
- Department of Pathology, Hong Kong Children's Hospital, Hong Kong, China; Department of Pathology, Queen Elizabeth Hospital, Hong Kong, China.
| | - Yuguo Li
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China.
| |
Collapse
|
24
|
Li Z, Wang Y, Zheng W, Wang H, Li B, Liu C, Wang Y, Lei C. Effect of inlet-outlet configurations on the cross-transmission of airborne bacteria between animal production buildings. JOURNAL OF HAZARDOUS MATERIALS 2022; 429:128372. [PMID: 35236040 DOI: 10.1016/j.jhazmat.2022.128372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 01/25/2022] [Accepted: 01/25/2022] [Indexed: 06/14/2023]
Abstract
Cross-transmission of airborne pathogens between buildings facilitates the spread of both human and animal diseases. Rational spatial arrangement of buildings and air inlet-outlet design are well-established preventive measures, but the effectiveness of current configurations for mitigating pathogens cross-transmission is still under assessment. An intensive field study in a laying hen farm was conducted to elucidate the spatial distribution of airborne bacteria (AB) and the source of AB at the inlets under different wind regimes. We found higher concentrations of AB at the interspace and sidewall inlets of buildings with sidewall exhaust systems than at those with endwall exhaust systems. We observed significant differences in bacterial diversity and richness at the interspace and sidewall inlets between buildings with side exhaust systems and those with endwall exhaust systems. We further found that the AB emitted from buildings could translocate to the sidewall inlets of adjacent building to a greater extent between buildings with sidewall exhaust systems than between those with endwall exhaust systems. Our findings revealed that sidewall exhaust systems aggravate cross-transmission of AB between buildings, suggesting that endwall exhaust systems or other compensatory preventive measures combined with sidewall exhaust systems could be a better choice to suppress airborne cross-transmission.
Collapse
Affiliation(s)
- Zonggang Li
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing, China; Key Laboratory of Agricultural Engineering in Structure and Environment, Ministry of Agriculture and Rural Affairs, Beijing, China; Beijing Engineering Research Center on Animal Healthy Environment, Beijing, China; Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, College of Veterinary Medicine, China Agricultural University, Beijing, China
| | - Yang Wang
- Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, College of Veterinary Medicine, China Agricultural University, Beijing, China
| | - Weichao Zheng
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing, China; Key Laboratory of Agricultural Engineering in Structure and Environment, Ministry of Agriculture and Rural Affairs, Beijing, China; Beijing Engineering Research Center on Animal Healthy Environment, Beijing, China.
| | - Hongning Wang
- College of Life Sciences, Sichuan University, Sichuan, China; Key Laboratory of Bio-Resource and Eco-Environment, Ministry of Education, Sichuan, China
| | - Baoming Li
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing, China; Key Laboratory of Agricultural Engineering in Structure and Environment, Ministry of Agriculture and Rural Affairs, Beijing, China; Beijing Engineering Research Center on Animal Healthy Environment, Beijing, China
| | - Chang Liu
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing, China; Key Laboratory of Agricultural Engineering in Structure and Environment, Ministry of Agriculture and Rural Affairs, Beijing, China; Beijing Engineering Research Center on Animal Healthy Environment, Beijing, China
| | - Yuxin Wang
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing, China; Key Laboratory of Agricultural Engineering in Structure and Environment, Ministry of Agriculture and Rural Affairs, Beijing, China; Beijing Engineering Research Center on Animal Healthy Environment, Beijing, China
| | - Changwei Lei
- College of Life Sciences, Sichuan University, Sichuan, China; Key Laboratory of Bio-Resource and Eco-Environment, Ministry of Education, Sichuan, China
| |
Collapse
|
25
|
The Aerosol-Generating Effect Among Noninvasive Positive Pressure Ventilation, High-Flow Nasal Cannula, Nonrebreather Mask, Nasal Cannula, and Ventilator-Assisted Preoxygenation. Ann Emerg Med 2022; 80:22-34. [DOI: 10.1016/j.annemergmed.2022.02.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 02/09/2022] [Accepted: 02/16/2022] [Indexed: 11/23/2022]
|
26
|
Exposure Risk to Medical Staff in a Nasopharyngeal Swab Sampling Cabin under Four Different Ventilation Strategies. BUILDINGS 2022. [DOI: 10.3390/buildings12030353] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Medical staff working in a nasopharyngeal swab sampling cabin are exposed to a higher exposure risk of COVID-19. In this study, computational fluid dynamics (CFD) are used to evaluate the exposure risk to medical staff in a nasopharyngeal swab sampling cabin of Chinese customs under four different ventilation strategies, i.e., multiple supply fans ventilation (MSFV), multiple exhaust fans ventilation (MEFV), single exhaust fan and outer windows closed ventilation (SEFV), and single exhaust fan and outer windows opened ventilation (SEFV-W). The impact of physical partitions on exposure risk is also discussed. The results show that MSFV performed best in reducing exposure risk. No significant difference was found between MEFV and SEFV. SEFV-W performed better than SEFV with a ventilation rate of 10–50 L/(s∙Person), while it performed worse with a ventilation rate of 50–90 L/(s∙Person). The exposure risk to medical staff did not decrease linearly with the increase in the ventilation flow rate under the four ventilation strategies. For MSFV, the installation of partitions is conducive to the reduction in the exposure risk. This study is expected to provide some guidance for ventilation designs in sampling cabins.
Collapse
|
27
|
Castellini JE, Faulkner CA, Zuo W, Lorenzetti DM, Sohn MD. Assessing the use of portable air cleaners for reducing exposure to airborne diseases in a conference room with thermal stratification. BUILDING AND ENVIRONMENT 2022; 207:108441. [PMID: 34720357 PMCID: PMC8548847 DOI: 10.1016/j.buildenv.2021.108441] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 09/24/2021] [Accepted: 10/11/2021] [Indexed: 05/29/2023]
Abstract
The COVID-19 pandemic has highlighted the need for strategies that mitigate the risk of aerosol disease transmission in indoor environments with different ventilation strategies. It is necessary for building operators to be able to estimate and compare the relative impacts of different mitigation strategies to determine suitable strategies for a particular situation. Using a validated CFD model, this study simulates the dispersion of exhaled contaminants in a thermally stratified conference room with overhead heating. The impacts of portable air-cleaners (PACs) on the room airflow and contaminant distribution were evaluated for different PAC locations and flow rates, as well as for different room setups (socially distanced or fully occupied). To obtain a holistic view of a strategy's impacts under different release scenarios, we simultaneously model the steady-state distribution of aerosolized virus contaminants from eight distinct sources in 18 cases for a total of 144 release scenarios. The simulations show that the location of the source, the PAC settings, and the room set-up can impact the average exposure and PAC effectiveness. For this studied case, the PACs reduced the room average exposure by 31%-66% relative to the baseline case. Some occupant locations were shown to have a higher-than-average exposure, particularly those seated near the airflow outlet, and occupants closest to sources tended to see the highest exposure from said source. We found that these PACs were effective at reducing the stratification caused by overhead heating, and also identified at least one sub-optimal location for placing a PAC in this space.
Collapse
Affiliation(s)
- John E Castellini
- Department of Mechanical Engineering, University of Colorado Boulder, UCB 427, Boulder, 80309, CO, USA
| | - Cary A Faulkner
- Department of Mechanical Engineering, University of Colorado Boulder, UCB 427, Boulder, 80309, CO, USA
| | - Wangda Zuo
- Department of Mechanical Engineering, University of Colorado Boulder, UCB 427, Boulder, 80309, CO, USA
- Department of Civil, Environmental and Architectural Engineering, University of Colorado Boulder, UCB 428, Boulder, 80309, CO, USA
- National Renewable Energy National Laboratory, Golden, 80401, CO, USA
| | - David M Lorenzetti
- Energy Analysis and Environmental Impacts Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, 94720, CA, USA
| | - Michael D Sohn
- Energy Analysis and Environmental Impacts Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, 94720, CA, USA
| |
Collapse
|
28
|
Zhang Y, Han O, Li A, Hou L, Olofsson T, Zhang L, Lei W. Adaptive Wall-Based Attachment Ventilation: A Comparative Study on Its Effectiveness in Airborne Infection Isolation Rooms with Negative Pressure. ENGINEERING (BEIJING, CHINA) 2022; 8:130-137. [PMID: 33520328 PMCID: PMC7825860 DOI: 10.1016/j.eng.2020.10.020] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 08/24/2020] [Accepted: 09/14/2020] [Indexed: 05/07/2023]
Abstract
The transmission of coronavirus disease 2019 (COVID-19) has presented challenges for the control of the indoor environment of isolation wards. Scientific air distribution design and operation management are crucial to ensure the environmental safety of medical staff. This paper proposes the application of adaptive wall-based attachment ventilation and evaluates this air supply mode based on contaminants dispersion, removal efficiency, thermal comfort, and operating expense. Adaptive wall-based attachment ventilation provides a direct supply of fresh air to the occupied zone. In comparison with a ceiling air supply or upper sidewall air supply, adaptive wall-based attachment ventilation results in a 15%-47% lower average concentration of contaminants, for a continual release of contaminants at the same air changes per hour (ACH; 10 h-1). The contaminant removal efficiency of complete mixing ventilation cannot exceed 1. For adaptive wall-based attachment ventilation, the contaminant removal efficiency is an exponential function of the ACH. Compared with the ceiling air supply mode or upper sidewall air supply mode, adaptive wall-based attachment ventilation achieves a similar thermal comfort level (predicted mean vote (PMV) of -0.1-0.4; draught rate of 2.5%-6.7%) and a similar performance in removing contaminants, but has a lower ACH and uses less energy.
Collapse
Affiliation(s)
- Ying Zhang
- School of Building Services Science and Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
- Department of Applied Physics and Electronics, Umeå University, Umeå SE 90187, Sweden
| | - Ou Han
- School of Building Services Science and Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Angui Li
- School of Building Services Science and Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
- Department of Applied Physics and Electronics, Umeå University, Umeå SE 90187, Sweden
- School of Thermal Engineering, Shandong Jianzhu University, Jinan 250101, China
| | - Li'an Hou
- School of Building Services Science and Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Thomas Olofsson
- Department of Applied Physics and Electronics, Umeå University, Umeå SE 90187, Sweden
| | - Linhua Zhang
- School of Thermal Engineering, Shandong Jianzhu University, Jinan 250101, China
| | - Wenjun Lei
- School of Thermal Engineering, Shandong Jianzhu University, Jinan 250101, China
| |
Collapse
|
29
|
Singer BC, Zhao H, Preble CV, Delp WW, Pantelic J, Sohn MD, Kirchstetter TW. Measured influence of overhead HVAC on exposure to airborne contaminants from simulated speaking in a meeting and a classroom. INDOOR AIR 2022; 32:e12917. [PMID: 34477251 DOI: 10.1111/ina.12917] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 07/08/2021] [Accepted: 07/11/2021] [Indexed: 06/13/2023]
Abstract
Tracer gas experiments were conducted in a 158 m3 room with overhead supply diffusers to study dispersion of contaminants from simulated speaking in physically distanced meeting and classroom configurations. The room was contained within a 237 m3 cell with open plenum return to the HVAC system. Heated manikins at desks and a researcher operating the tracer release apparatus presented 8-9 thermal plumes. Experiments were conducted under conditions of no forced air and neutral, cooled, or heated air supplied at 980-1100 cmh, and with/out 20% outdoor air. CO2 was released at the head of one manikin in each experiment to simulate small (<5 µm diameter) respiratory aerosols. The metric of exposure relative to perfectly mixed (ERM) is introduced to quantify impacts, based on measurements at manikin heads and at three heights in the center and corners of the room. Chilled or neutral supply air provided good mixing with ERMs close to one. Thermal stratification during heating produced higher ERMs at most manikins: 25% were ≥2.5 and the highest were >5× perfectly mixed conditions. Operation of two within-zone air cleaners together moving ≥400 cmh vertically in the room provided enough mixing to mitigate elevated exposure variations.
Collapse
Affiliation(s)
- Brett C Singer
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - Haoran Zhao
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - Chelsea V Preble
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
- Department of Civil & Environmental Engineering, University of California, Berkeley, California, USA
| | - William W Delp
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - Jovan Pantelic
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
- Center for the Built Environment, University of California, Berkeley, California, USA
| | - Michael D Sohn
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
| | - Thomas W Kirchstetter
- Indoor Environment Group, Energy Analysis and Environmental Impacts Division, Building Technologies and Urban Systems Division, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, California, USA
- Department of Civil & Environmental Engineering, University of California, Berkeley, California, USA
| |
Collapse
|
30
|
Dai YZ, Chen YJ, Zhang CY. A Simulation Analyzing Approach to Estimating the Probability of Airborne Infection Risks in Railway Station Platform Coupling with the Wells-Riley Model and Pathfinder Model. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:6066109. [PMID: 34970425 PMCID: PMC8714328 DOI: 10.1155/2021/6066109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 11/22/2021] [Indexed: 11/17/2022]
Abstract
Railway station platforms present a particular challenge, especially during a train departure or arrival where some passengers may have potential conditions that make them vulnerable to airborne infections due to the high density and close proximity of passengers. This study presented a simulation analyzing approach to estimating the probability of airborne infection risks in station platform spaces coupling with the Wells-Riley model and Pathfinder model. We examine the impact of overcrowded area of the station platform on infection rates under various traces of evacuation. The result of the potential risk for three modes is discussed, and the results of the standard model under the same parameter setting are optimised. Next, the impact of the ventilated volume based on uneven distribution of individuals and the exposure time based on evacuation on the infection risk in platform spaces are studied. The relationship between platform spaces overcrowding and the infection risk provided further insights to observe the supporting information.
Collapse
Affiliation(s)
- Yi-Zheng Dai
- School of Architecture, Southeast University, Nanjing, China
| | - Yan-Jiao Chen
- Shanghai Research Institute of Acupuncture and Meridian, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Chen-Yang Zhang
- School of Architecture, Southeast University, Nanjing, China
| |
Collapse
|
31
|
Cao SJ, Feng Z, Wang J, Ren C, Zhu HC, Chen G, Mei J. Ergonomics-oriented operation, maintenance and control of indoor air environment for public buildings. CHINESE SCIENCE BULLETIN-CHINESE 2021. [DOI: 10.1360/tb-2021-1024] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
32
|
Liu Y, Pan W, Long Z. Optimization of air supply parameters for stratum ventilation based on proper orthogonal decomposition. SUSTAINABLE CITIES AND SOCIETY 2021; 75:103291. [PMID: 34458075 PMCID: PMC8379829 DOI: 10.1016/j.scs.2021.103291] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 08/19/2021] [Accepted: 08/19/2021] [Indexed: 05/24/2023]
Abstract
Under the current COVID-19 epidemic conditions, stratum ventilation can provide treated fresh air directly into the human breathing zone, improving the air quality for inhalation. However, in the design of air supply parameters for stratum ventilation, the traditional trial-and-error and experimental methods are inefficient and time consuming, and they cannot be used to identify the optimal air supply parameters from a large number of parameters. Therefore, in this paper, the inverse design method based on proper orthogonal decomposition (POD) was applied to the design of ventilation parameters for a room with stratum ventilation. Predicted mean vote (PMV), predicted percentage dissatisfied (PPD) and droplet nuclei concentration in the human breathing zone were selected as design objectives to optimize air supply parameters. The transmission of COVID-19 was controlled by reducing the concentration of droplet nuclei in the respiratory area. The results show that, compared with the trial-and-error method, the inverse design method based on POD is more than 90% faster. POD method can greatly expand the sample size. Considering the dispersion of exhaled droplet nuclei in the room, the appropriate stratum ventilation parameters can reduce the concentration of fine droplet nuclei by more than 20% compared with the traditional design parameters.
Collapse
Affiliation(s)
- Yang Liu
- Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China
| | - Wuxuan Pan
- Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China
| | - Zhengwei Long
- Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China
| |
Collapse
|
33
|
Abstract
Respiratory aerosols from breathing and talking are an important transmission route for viruses, including severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Previous studies have found that particles with diameters ranging from 10 nm to 145 μm are produced from different regions in the respiratory system and especially smaller particles can remain airborne for long periods while carrying viral RNA. We present the first study in which respiratory aerosols have been simultaneously measured with carbon dioxide (CO2) to establish the correlation between the two concentrations. CO2 concentrations are easily available through low-cost sensors and could be used to estimate viral exposure through this correlation, whereas source-specific aerosol measurements are complicated and not possible with low-cost sensors. The increase in both respiratory aerosols and CO2 was linear over ten minutes in a 2 m3 chamber for all participants, suggesting a strong correlation. On average, talking released more particles than breathing, with 14,600 ± 16,800 min−1 (one-σ standard deviation) and 6210 ± 5630 min−1 on average, respectively, while CO2 increased with 139 ± 33 ppm min−1 during talking and 143 ± 29 ppm min−1 during breathing. Assuming a typical viral load of 7×106 RNA copies per mL of oral fluid, ten minutes of talking and breathing are estimated to produce 1 and 16 suspended RNA copies, respectively, correlating to a CO2 concentration of around 1800 ppm in a 2 m3 chamber. However, viral loads can vary by several orders of magnitude depending on the stage of the disease and the individual. It was therefore concluded that, by measuring CO2 concentrations, only the number and volume concentrations of released particles can be estimated with reasonable certainty, while the number of suspended RNA copies cannot.
Collapse
|
34
|
Li X, Mak CM, Wai Ma K, Wong HM. How the high-volume evacuation alters the flow-field and particle removal characteristics in the mock-up dental clinic. BUILDING AND ENVIRONMENT 2021; 205:108225. [PMID: 34376905 PMCID: PMC8343392 DOI: 10.1016/j.buildenv.2021.108225] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 07/17/2021] [Accepted: 08/02/2021] [Indexed: 05/09/2023]
Abstract
The exposure risk of droplets and aerosols emitted from the oral cavity to the dental professionals and patients has received more attention especially the ongoing outbreak of COVID-19. The aim of this study is to address the question about how the use of the high-volume evacuation (HVE) alters the risk profiles compared with the situation only personal protective equipment (PPE). The risk profiles of the different situations were analyzed in terms of droplet velocity, flow field characteristics, and particle removal efficiency. The ultrasonic scaling with suction was performed in the mock-up experimental dental clinic, and the instantaneous moment when the HVE acted on the droplets was visualized using a laser light scattering technique. From the results of the velocity profiles, the hypothesis about the moderate effect of the HVE on high-velocity small droplets near the mannequin's mouth had been firstly proven in this study. The suction can be characterized as low-threshold equipment to bring substantial benefits to reduce the area of the contaminated region. Once the cooperation of suction, the pair of vortexes that were in the face shield area of the dental professional would be eliminated, removing the high-level contaminated region near the breathing area of dental professionals. Compared with the low and medium volume evacuation, the particle removal efficiency of the HVE was more stable at 60%. The research will provide references to the HVE recommendation in the dentistry clinical practice guidelines.
Collapse
Affiliation(s)
- Xiujie Li
- Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong
| | - Cheuk Ming Mak
- Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong
| | - Kuen Wai Ma
- Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong
| | - Hai Ming Wong
- Faculty of Dentistry, The University of Hong Kong, Pok Fu Lam, Hong Kong Island, Hong Kong
| |
Collapse
|
35
|
Ren C, Xi C, Wang J, Feng Z, Nasiri F, Cao SJ, Haghighat F. Mitigating COVID-19 infection disease transmission in indoor environment using physical barriers. SUSTAINABLE CITIES AND SOCIETY 2021; 74:103175. [PMID: 34306996 PMCID: PMC8278843 DOI: 10.1016/j.scs.2021.103175] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 06/29/2021] [Accepted: 07/08/2021] [Indexed: 05/05/2023]
Abstract
During the normalized phase of COVID-19, droplets or aerosol particles produced by infected personnel are considered as the potential source of infection with uncertain exposure risk. As such, in densely populated open spaces, it is necessary to adopt strategies to mitigate the risk of infection disease transmission while providing sufficient ventilation air. An example of such strategies is use of physical barriers. In this study, the impact of barrier heights on the spread of aerosol particles is investigated in an open office environment with the well-designed ventilation mode and supply air rate. The risk of infection disease transmission is evaluated using simulation of particle concentration in different locations and subject to a number of source scenarios. It was found that a barrier height of at least 60 cm above the desk surface is needed to effectively prevent the transmission of viruses. For workstations within 4 m from the outlet, a 70 cm height is considered, and with a proper ventilation mode, it is shown that the barriers can reduce the risk of infection by 72%. However, for the workstations further away from the outlet (beyond 4 m), the effect of physical barrier cannot be that significant. In summary, this study provides a theoretical analysis for implementing physical barriers, as a low-cost mitigation strategy, subject to various height scenarios and investigation of their effectiveness in reducing the infection transmission probability.
Collapse
Affiliation(s)
- Chen Ren
- School of Architecture, Southeast University, 2 Sipailou, Nanjing, 210096, China
| | - Chang Xi
- School of Architecture, Southeast University, 2 Sipailou, Nanjing, 210096, China
| | - Junqi Wang
- School of Architecture, Southeast University, 2 Sipailou, Nanjing, 210096, China
| | - Zhuangbo Feng
- School of Architecture, Southeast University, 2 Sipailou, Nanjing, 210096, China
| | - Fuzhan Nasiri
- Energy and Environment Group, Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, H3G 1M8, Canada
| | - Shi-Jie Cao
- School of Architecture, Southeast University, 2 Sipailou, Nanjing, 210096, China
- Global Centre for Clean Air Research, Department of Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, United Kingdom
| | - Fariborz Haghighat
- School of Architecture, Southeast University, 2 Sipailou, Nanjing, 210096, China
- Energy and Environment Group, Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, H3G 1M8, Canada
| |
Collapse
|
36
|
Hassan AM, Megahed NA. COVID-19 and urban spaces: A new integrated CFD approach for public health opportunities. BUILDING AND ENVIRONMENT 2021; 204:108131. [PMID: 34305269 PMCID: PMC8273043 DOI: 10.1016/j.buildenv.2021.108131] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 06/29/2021] [Accepted: 07/07/2021] [Indexed: 05/30/2023]
Abstract
Safe urban public spaces are vital owing to their impacts on public health, especially during pandemics such as the ongoing COVID-19 pandemic. Urban public spaces and urbanscape elements must be designed with the risk of viral transmission in mind. This work therefore examines how the design of urbanscape elements can be revisited to control COVID-19 transmission dynamics. Nine proposed models of urban public seating were thus presented and assessed using a transient three-dimensional computational fluid dynamics (CFD) model, with the Eulerian-Lagrangian method and discrete phase model (DPM). The proposed seating models were evaluated by their impact on the normalized air velocity, the diameter of coughing droplets, and deposition fraction. Each of the proposed models demonstrated an increase in the normalized velocity, and a decrease in the deposition fraction by >29%. Diagonal cross linear and curved triangle configurations demonstrated an improved airflow momentum and turbulent flow, which decreased the droplets deposition fraction by 68%, thus providing an improved, healthier urban public seating option.
Collapse
Affiliation(s)
- Asmaa M Hassan
- Architectural Engineering and Urban Planning Department, Faculty of Engineering, Port Said University, Port Said, Egypt
| | - Naglaa A Megahed
- Architectural Engineering and Urban Planning Department, Faculty of Engineering, Port Said University, Port Said, Egypt
| |
Collapse
|
37
|
Deng X, Gong G, He X, Shi X, Mo L. Control of exhaled SARS-CoV-2-laden aerosols in the interpersonal breathing microenvironment in a ventilated room with limited space air stability. J Environ Sci (China) 2021; 108:175-187. [PMID: 34465431 PMCID: PMC7835081 DOI: 10.1016/j.jes.2021.01.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 01/20/2021] [Accepted: 01/21/2021] [Indexed: 05/31/2023]
Abstract
The Coronavirus Disease 2019 (COVID-19) highlights the importance of understanding and controlling the spread of the coronavirus between persons. We experimentally and numerically investigated an advanced engineering and environmental method on controlling the transmission of airborne SARS-CoV-2-laden aerosols in the breathing microenvironment between two persons during interactive breathing process by combining the limited space air stability and a ventilation method. Experiments were carried out in a full-scale ventilated room with different limited space air stability conditions, i.e., stable condition, neutral condition and unstable condition. Two real humans were involved to conducted normal breathing process in the room and the exhaled carbon dioxide was used as the surrogate of infectious airborne SARS-CoV-2-laden aerosols from respiratory activities. A correspondent numerical model was established to visualize the temperature field and contaminated field in the test room. Results show that the performance of a ventilation system on removing infectious airborne SARS-CoV-2-laden aerosols from the interpersonal breathing microenvironment is dependent on the limited space air stability conditions. Appropriate ventilation method should be implemented based on an evaluation of the air condition. It is recommended that total volume ventilation methods are suitable for unstable and neutral conditions and local ventilation methods are preferable for stable conditions. This study provides an insight into the transmission of airborne SARS-CoV-2-laden aerosols between persons in ventilated rooms with different limited space air stability conditions. Useful guidance has been provided to cope with COVID-19 in limited spaces.
Collapse
Affiliation(s)
- Xiaorui Deng
- College of Civil Engineering, Hunan University, Changsha 410082, China; Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha 410082, China
| | - Guangcai Gong
- College of Civil Engineering, Hunan University, Changsha 410082, China; Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha 410082, China.
| | - Xizhi He
- College of Civil Engineering, Hunan University, Changsha 410082, China; Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha 410082, China
| | - Xing Shi
- College of Civil Engineering, Hunan University, Changsha 410082, China; Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha 410082, China
| | - Lan Mo
- Yiyang Engineering Co., Ltd., Yiyang 413000, China
| |
Collapse
|
38
|
Deng X, Gong G, Chen S, He X, Ou Y, Wang Y. Assessment of personal exposure to infectious contaminant under the effect of indoor air stability. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:39322-39332. [PMID: 33755892 PMCID: PMC7986142 DOI: 10.1007/s11356-021-13443-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Accepted: 03/10/2021] [Indexed: 06/12/2023]
Abstract
The objective of this study is to understand the effect of indoor air stability on personal exposure to infectious contaminant in the breathing zone. Numerical simulations are carried out in a test chamber with a source of infectious contaminant and a manikin (Manikin A). To give a good visual illustration of the breathing zone, the contaminant source is visualized by the mouth of another manikin. Manikin A is regarded as a vulnerable individual to infectious contaminant. Exposure index and exposure intensity are used as indicators of the exposure level in the breathing zone. The results show that in the stable condition, the infectious contaminant proceeds straightly towards the breathing zone of the vulnerable individual, leading to a relatively high exposure level. In the unstable condition, the indoor air experiences a strong mixing due to the heat exchange between the hot bottom air and the cool top air, so the infectious contaminant disperses effectively from the breathing zone. The unstable air can greatly reduce personal exposure to the infectious contaminant in the breathing zone. This study demonstrates the importance of indoor air stability on personal exposure in the indoor environment and provides a new direction for future study of personal exposure reduction in the indoor environment.
Collapse
Affiliation(s)
- Xiaorui Deng
- Department of Building Environment and Energy Engineering, College of Civil Engineering, Hunan University, Changsha, 410082, Hunan, China
- Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha, 410082, China
| | - Guangcai Gong
- Department of Building Environment and Energy Engineering, College of Civil Engineering, Hunan University, Changsha, 410082, Hunan, China.
- Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha, 410082, China.
| | - Shanquan Chen
- School of Clinical Medicine, University of Cambridge, Cambridge, CB2 3EB, UK
| | - Xizhi He
- Department of Building Environment and Energy Engineering, College of Civil Engineering, Hunan University, Changsha, 410082, Hunan, China
- Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha, 410082, China
| | - Yongshen Ou
- Department of Building Environment and Energy Engineering, College of Civil Engineering, Hunan University, Changsha, 410082, Hunan, China
- Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha, 410082, China
| | - Yadi Wang
- Department of Building Environment and Energy Engineering, College of Civil Engineering, Hunan University, Changsha, 410082, Hunan, China
- Key Laboratory of Building Safety and Energy Efficiency, Ministry of Education, Hunan University, Changsha, 410082, China
| |
Collapse
|
39
|
Peng Z, Jimenez JL. Exhaled CO 2 as a COVID-19 Infection Risk Proxy for Different Indoor Environments and Activities. ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS 2021; 8:392-397. [PMID: 37566374 PMCID: PMC8043197 DOI: 10.1021/acs.estlett.1c00183] [Citation(s) in RCA: 97] [Impact Index Per Article: 32.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 04/01/2021] [Accepted: 04/02/2021] [Indexed: 05/21/2023]
Abstract
CO2 is co-exhaled with aerosols containing SARS-CoV-2 by COVID-19-infected people and can be used as a proxy of SARS-CoV-2 concentrations indoors. Indoor CO2 measurements by low-cost sensors hold promise for mass monitoring of indoor aerosol transmission risk for COVID-19 and other respiratory diseases. We derive analytical expressions of CO2-based risk proxies and apply them to various typical indoor environments. The relative infection risk in a given environment scales with excess CO2 level, and thus, keeping CO2 as low as feasible in a space allows optimization of the protection provided by ventilation. We show that the CO2 level corresponding to a given absolute infection risk varies by >2 orders of magnitude for different environments and activities. Although large uncertainties, mainly from virus exhalation rates, are still associated with infection risk estimates, our study provides more specific and practical recommendations for low-cost CO2-based indoor infection risk monitoring.
Collapse
Affiliation(s)
- Zhe Peng
- Cooperative Institute for Research in Environmental Sciences and Department
of Chemistry, University of Colorado, Boulder, Colorado 80309,
United States
| | - Jose L. Jimenez
- Cooperative Institute for Research in Environmental Sciences and Department
of Chemistry, University of Colorado, Boulder, Colorado 80309,
United States
| |
Collapse
|
40
|
Zhang S, Lin Z. Dilution-based evaluation of airborne infection risk - Thorough expansion of Wells-Riley model. BUILDING AND ENVIRONMENT 2021; 194:107674. [PMID: 33583999 DOI: 10.1101/2020.10.03.20206391] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 01/16/2021] [Accepted: 02/03/2021] [Indexed: 05/25/2023]
Abstract
Evaluation of airborne infection risk with spatial and temporal resolutions is indispensable for the design of proper interventions fighting infectious respiratory diseases (e.g., COVID-19), because the distribution of aerosol contagions is both spatially and temporally non-uniform. However, the well-recognized Wells-Riley model and modified Wells-Riley model (i.e., the rebreathed-fraction model) are limited to the well-mixed condition and unable to evaluate airborne infection risk spatially and temporally, which could result in overestimation or underestimation of airborne infection risk. This study proposes a dilution-based evaluation method for airborne infection risk. The method proposed is benchmarked by the Wells-Riley model and modified Wells-Riley model, which indicates that the method proposed is a thorough expansion of the Wells-Riley model for evaluation of airborne infection risk with both spatial and temporal resolutions. Experiments in a mock hospital ward also demonstrate that the method proposed effectively evaluates the airborne infection risk both spatially and temporally. The proposed method is convenient to implement for the development of healthy built environments.
Collapse
Affiliation(s)
- Sheng Zhang
- Division of Building Science and Technology, City University of Hong Kong, Hong Kong, China
| | - Zhang Lin
- Division of Building Science and Technology, City University of Hong Kong, Hong Kong, China
| |
Collapse
|
41
|
Zhang S, Lin Z. Dilution-based evaluation of airborne infection risk - Thorough expansion of Wells-Riley model. BUILDING AND ENVIRONMENT 2021; 194:107674. [PMID: 33583999 PMCID: PMC7871780 DOI: 10.1016/j.buildenv.2021.107674] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 01/16/2021] [Accepted: 02/03/2021] [Indexed: 05/05/2023]
Abstract
Evaluation of airborne infection risk with spatial and temporal resolutions is indispensable for the design of proper interventions fighting infectious respiratory diseases (e.g., COVID-19), because the distribution of aerosol contagions is both spatially and temporally non-uniform. However, the well-recognized Wells-Riley model and modified Wells-Riley model (i.e., the rebreathed-fraction model) are limited to the well-mixed condition and unable to evaluate airborne infection risk spatially and temporally, which could result in overestimation or underestimation of airborne infection risk. This study proposes a dilution-based evaluation method for airborne infection risk. The method proposed is benchmarked by the Wells-Riley model and modified Wells-Riley model, which indicates that the method proposed is a thorough expansion of the Wells-Riley model for evaluation of airborne infection risk with both spatial and temporal resolutions. Experiments in a mock hospital ward also demonstrate that the method proposed effectively evaluates the airborne infection risk both spatially and temporally. The proposed method is convenient to implement for the development of healthy built environments.
Collapse
Affiliation(s)
- Sheng Zhang
- Division of Building Science and Technology, City University of Hong Kong, Hong Kong, China
| | - Zhang Lin
- Division of Building Science and Technology, City University of Hong Kong, Hong Kong, China
| |
Collapse
|
42
|
Guo Y, Qian H, Sun Z, Cao J, Liu F, Luo X, Ling R, Weschler LB, Mo J, Zhang Y. Assessing and controlling infection risk with Wells-Riley model and spatial flow impact factor (SFIF). SUSTAINABLE CITIES AND SOCIETY 2021; 67:102719. [PMID: 33520610 PMCID: PMC7834120 DOI: 10.1016/j.scs.2021.102719] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 12/31/2020] [Accepted: 01/12/2021] [Indexed: 05/13/2023]
Abstract
The ongoing COVID-19 epidemic has spread worldwide since December 2019. Effective use of engineering controls can prevent its spread and thereby reduce its impact. As airborne transmission is an important mode of infectious respiratory disease transmission, mathematical models of airborne infection are needed to develop effective engineering control. We developed a new approach to obtain the spatial distribution for the probability of infection (PI) by combining the spatial flow impact factor (SFIF) method with the Wells-Riley model. Our method can be combined with the anti-problem approach, in order to determine the optimized arrangement of people and/or air purifiers in a confined space beyond the ability of previous methods. This method was validated by a CFD-integrated method, and an illustrative example is presented. We think our method can be helpful in controlling infection risk and making the best use of the space and equipment in built environments, which is important for preventing the spread of COVID-19 and other infectious respiratory diseases, and promoting the development of sustainable cities and society.
Collapse
Affiliation(s)
- Yong Guo
- Department of Building Science, Tsinghua University, Beijing, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - Hua Qian
- School of Energy and Environment, Southeast University, Nanjing, China
| | - Zhiwei Sun
- Department of Building Science, Tsinghua University, Beijing, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - Jianping Cao
- School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou, China
| | - Fei Liu
- Hubei Provincial Hospital of Integrated Chinese and Western Medicine, Wuhan, China
| | - Xibei Luo
- Hubei Provincial Hospital of Integrated Chinese and Western Medicine, Wuhan, China
| | - Ruijie Ling
- Hubei Provincial Hospital of Integrated Chinese and Western Medicine, Wuhan, China
| | | | - Jinhan Mo
- Department of Building Science, Tsinghua University, Beijing, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - Yinping Zhang
- Department of Building Science, Tsinghua University, Beijing, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| |
Collapse
|
43
|
Li X, Mak CM, Ma KW, Wong HM. Evaluating flow-field and expelled droplets in the mockup dental clinic during the COVID-19 pandemic. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:047111. [PMID: 33953531 PMCID: PMC8086643 DOI: 10.1063/5.0048848] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Accepted: 04/03/2021] [Indexed: 05/07/2023]
Abstract
In the setting of widespread severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) community transmission, reducing the exposure risk on dental professionals and the next patients is the key to reopening dental services in this pandemic environment. The study is motivated by the lack of understanding of the flow-field characteristics and droplet distribution during aerosol-generating procedures. The particle image velocimetry measurements with high temporal and spatial resolutions were performed under ultrasonic scaling in the mockup experimental dental clinic. Compared with other methods focusing on the settled droplet particles, the study focused on the visualization of suspended droplets. From the results of the velocity vector and trajectory map, the high-level contaminated area will be within 1 m from the oral cavity. The vortex structures were identified by the vorticity index. In the surface near the patient's head, a counterclockwise vortex would carry some droplets and contaminate this region. The small droplets circulated in the turbulence cloud and the droplet nuclei generated by dehydration are the two primary sources of suspended particles, which may cause airborne transmission in the dental clinic. About 65%-74% of the droplets in ultrasonic scaling were in the range of 50-180 μ m . The research will provide references to the development of the precaution measures to reduce the SARS-CoV-2 exposure risk of dental professionals.
Collapse
Affiliation(s)
- Xiujie Li
- Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong, China
| | - Cheuk Ming Mak
- Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong, China
| | - Kuen Wai Ma
- Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong, China
| | - Hai Ming Wong
- Faculty of Dentistry, The University of Hong Kong, Pok Fu Lam, Hong Kong Island, Hong Kong, China
| |
Collapse
|
44
|
Nazir R, Ali J, Rasul I, Widemann E, Shafiq S. Eco-Environmental Aspects of COVID-19 Pandemic and Potential Control Strategies. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:3488. [PMID: 33801704 PMCID: PMC8037994 DOI: 10.3390/ijerph18073488] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 03/14/2021] [Accepted: 03/24/2021] [Indexed: 01/10/2023]
Abstract
A new coronavirus-strain from a zoonotic reservoir (probably bat)-termed as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-has recently claimed more than two million deaths worldwide. Consequently, a burst of scientific reports on epidemiology, symptoms, and diagnosis came out. However, a comprehensive understanding of eco-environmental aspects that may contribute to coronavirus disease 2019 (COVID-19) spread is still missing, and we therefore aim to focus here on these aspects. In addition to human-human direct SARS-CoV-2 transmission, eco-environmental sources, such as air aerosols, different public use objects, hospital wastes, livestock/pet animals, municipal wastes, ventilation facilities, soil and groundwater potentially contribute to SARS-CoV-2 transmission. Further, high temperature and humidity were found to limit the spread of COVID-19. Although the COVID-19 pandemic led to decrease air and noise pollution during the period of lockdown, increased use of masks and gloves is threatening the environment by water and soil pollutions. COVID-19 badly impacted all the socio-economic groups in different capacities, where women, slum dwellers, and the people lacking social protections are the most vulnerable. Finally, sustainable strategies, waste management, biodiversity reclaim, eco-friendly lifestyle, improved health infrastructure and public awareness, were proposed to minimize the COVID-19 impact on our society and environment. These strategies will seemingly be equally effective against any future outbreak.
Collapse
Affiliation(s)
- Rashid Nazir
- Department of Environmental Sciences, Abbottabad Campus, COMSATS University Islamabad, University Road, Abbottabad 22060, Pakistan;
| | - Jawad Ali
- Department of Biotechnology, Abbottabad Campus, Tobe Camp, COMSATS University Islamabad, University Road, Abbottabad 22060, Pakistan;
| | - Ijaz Rasul
- Plant Virology Section, Department of Bioinformatics and Biotechnology, Government College University Faisalabad, Faisalabad 38000, Pakistan;
| | - Emilie Widemann
- Department of Biology, University of Western Ontario, London, ON N6A5B7, Canada;
| | - Sarfraz Shafiq
- Department of Anatomy and Cell Biology, University of Western Ontario, London, ON N6A3K7, Canada
| |
Collapse
|
45
|
Sussman RA, Golberstein E, Polosa R. Aerial Transmission of the SARS-CoV-2 Virus through Environmental E-Cigarette Aerosols: Implications for Public Policies. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:1437. [PMID: 33546515 PMCID: PMC7913611 DOI: 10.3390/ijerph18041437] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 01/27/2021] [Accepted: 01/29/2021] [Indexed: 12/15/2022]
Abstract
We discuss the implications of possible contagion of COVID-19 through e-cigarette aerosol (ECA) for prevention and mitigation strategies during the current pandemic. This is a relevant issue when millions of vapers (and smokers) must remain under indoor confinement and/or share public outdoor spaces with non-users. The fact that the respiratory flow associated with vaping is visible (as opposed to other respiratory activities) clearly delineates a safety distance of 1-2 m along the exhaled jet to prevent direct exposure. Vaping is a relatively infrequent and intermittent respiratory activity for which we infer a mean emission rate of 79.82 droplets per puff (6-200, standard deviation 74.66) comparable to mouth breathing, it adds into shared indoor spaces (home and restaurant scenarios) a 1% extra risk of indirect COVID-19 contagion with respect to a "control case" of existing unavoidable risk from continuous breathing. As a comparative reference, this added relative risk increases to 44-176% for speaking 6-24 min per hour and 260% for coughing every 2 min. Mechanical ventilation decreases absolute emission levels but keeps the same relative risks. As long as direct exposure to the visible exhaled jet is avoided, wearing of face masks effectively protects bystanders and keeps risk estimates very low. As a consequence, protection from possible COVID-19 contagion through vaping emissions does not require extra interventions besides the standard recommendations to the general population: keeping a social separation distance of 2 m and wearing of face masks.
Collapse
Affiliation(s)
- Roberto A. Sussman
- Institute of Nuclear Sciences, National Autonomous University of Mexico, 04510 Mexico City, Mexico
| | | | - Riccardo Polosa
- Center of Excellence for the Acceleration of Harm Reduction (CoEHAR), University of Catania, 95123 Catania, Italy;
| |
Collapse
|
46
|
Leng J, Wang Q, Liu K. Sustainable design of courtyard environment: From the perspectives of airborne diseases control and human health. SUSTAINABLE CITIES AND SOCIETY 2020; 62:102405. [PMID: 32834938 PMCID: PMC7367033 DOI: 10.1016/j.scs.2020.102405] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2020] [Revised: 07/11/2020] [Accepted: 07/14/2020] [Indexed: 05/20/2023]
Abstract
Courtyards have functioned as an effective passive architectural design strategy for various climate conditions, especially popular in hot-humid climates. Sustainable and delicate designs are necessary to create safe, healthy and comfortable courtyard environment. Most of the available literature focused on thermal comfort for courtyard, and the researches towards air pollution/disease control was rare. Further considering the severe impact of COVID-19 crisis, the current study aims to develop a numerical strategy to optimize physical environment in courtyard, including distributions of airborne pollutant, drought sensation and infection risk. Experimental data from literature was used to validate the numerical models. The evaluation indexes were adopted for the assessment of draft sensation, pollution exposure risk etc. The influences of geometric design parameters (i.e., courtyard width, height etc.) were investigated, and courtyard width (D) was the most sensitive parameter. If D increased from 5.8 m to 11.8 m, average air pollutant concentration decreased by 80 %, while drought sensation increased by 30 %. In static wind conditions, infection possibility (with R value up to 3 %) in courtyard was comparable to those in indoor environments during the COVID-19 period. This work will be of great importance for sustainable development of courtyards from the perspectives of airborne diseases control.
Collapse
Affiliation(s)
- Jiawei Leng
- School of Architecture, Southeast University, Sipailou, Nanjing, 210096 China
| | - Qi Wang
- Architects & Engineers Co. Ltd. of Southeast University, Sipailou, Nanjing, 210096, China
| | - Ke Liu
- School of Architecture, Southeast University, Sipailou, Nanjing, 210096 China
| |
Collapse
|