1
|
Molecular Insights and Clinical Outcomes of Drugs of Abuse Adulteration: New Trends and New Psychoactive Substances. Int J Mol Sci 2022; 23:ijms232314619. [PMID: 36498947 PMCID: PMC9739917 DOI: 10.3390/ijms232314619] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/18/2022] [Accepted: 11/21/2022] [Indexed: 11/24/2022] Open
Abstract
Adulteration is a well-known practice of drug manufacturers at different stages of drug production. The intentional addition of active ingredients to adulterate the primary drug may enhance or mask pharmacological effects or may produce more potent drugs to increase the number of available doses and the dealer's profit. Adulterants found in different drugs change over time in response to different factors. A systematic literature search in PubMed and Scopus databases and official international organizations' websites according to PRISMA guidelines was performed. A total of 724 studies were initially screened, with 145 articles from PubMed and 462 from Scopus excluded according to the criteria described in the Method Section. The remaining 117 records were further assessed for eligibility to exclude articles without sufficient data. Finally, 79 studies were classified as "non-biological" (n = 35) or "biological" (n = 35 case reports; n = 9 case series) according to the samples investigated. Although the seized samples analyses revealed the presence of well-established adulterants such as levamisole for cocaine or paracetamol/acetaminophen for heroin, the reported data disclosed new adulteration practices, such as the use of NPS as cutting agents for classic drugs of abuse and other NPS. For example, heroin adulterated with synthetic cannabinoids or cocaine adulterated with fentanyl/fentalogues raised particular concern. Notably, adulterants play a role in some adverse effects commonly associated with the primary drug, such as levamisole-adulterated cocaine that may induce vasculitis via an autoimmune process. It is essential to constantly monitor adulterants due to their changing availability that may threaten drug consumers' health.
Collapse
|
2
|
Mercier B, Scala-Bertola J, Pape E, Kolodziej A, Gibaja V, Bisch M, Jouzeau JY, Gambier N. Online SPE UPLC-MS/MS method for the simultaneous determination of 33 psychoactive drugs from swab-collected human oral fluid samples. Anal Bioanal Chem 2022; 414:4203-4215. [PMID: 35451622 DOI: 10.1007/s00216-022-04073-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 03/30/2022] [Accepted: 04/06/2022] [Indexed: 11/01/2022]
Abstract
Oral fluid is easy and safe to collect and allows the detection of drugs of abuse after local exposure by oral, smoked, and/or inhaled intake, or systemic exposure. A routine online solid-phase extraction UPLC-MS/MS method was developed for the simultaneous determination of 33 psychoactive drugs in oral fluid. The selected drugs were fourteen fentanyl analogs and nineteen other abused psychoactive compounds, including classical narcotics, which were analyzed in a run of 10 min. Limits of detection and of quantification ranged from 0.02 to 1 ng/mL and from 0.02 to 5 ng/mL depending on the analyte, respectively. Matrix effect was in the range - 17 to + 15.7% for all analytes having a deuterated analog. Accuracy ranged from 82.7 to 113.4% and precision CV was at worst of 18.6%. Carryover was below 0.8% for all analytes. Recovery from FLOQSwabs™ showed high variability between analytes with THC, D2FF, 4-ANPP, ocfentanil, and valerylfentanyl being recovered below 40%. A stability study performed over 2 weeks on collecting devices loaded with artificial oral fluid showed huge variation between analytes with morphine, BZE, and norfentanyl being the more stable. Storage at 4 °C allowed drug detection for 1 week except for THC and remifentanil. The method was successfully applied to the detection of abused psychoactive compounds in oral fluid samples from 6 patients admitted to an addiction department.
Collapse
Affiliation(s)
- Benoit Mercier
- Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France
| | - Julien Scala-Bertola
- Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France
- Université de Lorraine, CNRS, IMoPA, 54505, Vandœuvre, France
| | - Elise Pape
- Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France
- Université de Lorraine, CNRS, IMoPA, 54505, Vandœuvre, France
| | - Allan Kolodziej
- Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France
| | - Valérie Gibaja
- Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France
| | - Michael Bisch
- Centre Psychothérapique de Nancy, Département d'Addictologie, Pôle Hospitalo-Universitaire du Grand Nancy, 54520, Laxou, France
| | - Jean-Yves Jouzeau
- Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France
- Université de Lorraine, CNRS, IMoPA, 54505, Vandœuvre, France
| | - Nicolas Gambier
- Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France.
- Université de Lorraine, CNRS, IMoPA, 54505, Vandœuvre, France.
| |
Collapse
|
3
|
Delaney SR, Tacker DH, Snozek CLH. The North American opioid epidemic: opportunities and challenges for clinical laboratories. Crit Rev Clin Lab Sci 2022; 59:309-331. [PMID: 35166639 DOI: 10.1080/10408363.2022.2037122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Since 1999, the opioid epidemic in North America has resulted in over 1 million deaths, and it continues to escalate despite numerous efforts in various arenas to combat the upward trend. Clinical laboratories provide drug testing to support practices such as emergency medicine, substance use disorder treatment, and pain management; increasingly, these laboratories are collaborating in novel partnerships including drug-checking services (DCS) and multidisciplinary treatment teams. This review examines drug testing related to management of licit and illicit opioid use, new technologies and test strategies employed by clinical laboratories, barriers hindering laboratory response to the opioid epidemic, and areas for improvement and standardization within drug testing. Literature search terms included combinations of "opioid," "opiate," "fentanyl," "laboratory," "epidemic," "crisis," "mass spectrometry," "immunoassay," "drug screen," "drug test," "guidelines," plus review of PubMed "similar articles" and references within publications. While immunoassay (IA) and point-of-care (POC) test options for synthetic opioids are increasingly available, mass spectrometry (MS) platforms offer the greatest flexibility and sensitivity for detecting novel, potent opioids. Previously reserved as a second-tier application in most drug test algorithms, MS assays are gaining a larger role in initial screening for specific patients and DCS. However, there are substantial differences among laboratories in terms of updating test menus, algorithms, and technologies to meet changing clinical needs. While some clinical laboratories lack the resources and expertise to implement MS, many are also slow to adopt available IA and POC tests for newer opioids such as fentanyl. MS-based testing also presents challenges, including gaps in available guidance for assay validation and ongoing performance assessment that contribute to a dramatic lack of standardization among laboratories. We identify opportunities for improvement in laboratory operations, reporting, and interpretation of drug test results, including laboratorian and provider education and laboratory-focused guidelines. We also highlight the need for collaboration with providers, assay and instrument manufacturers, and national organizations to increase the effectiveness of clinical laboratory and provider efforts in preventing morbidity and mortality associated with opioid use and misuse.
Collapse
Affiliation(s)
- Sarah R Delaney
- Department of Laboratory Medicine, St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada.,Department of Laboratory Medicine & Pathobiology, University of Toronto, Toronto, ON, Canada
| | - Danyel H Tacker
- Department of Pathology, Anatomy, and Laboratory Medicine, West Virginia University School of Medicine, Morgantown, WV, USA
| | - Christine L H Snozek
- Department of Laboratory Medicine and Pathology, Mayo Clinic Arizona, Phoenix, AZ, USA
| |
Collapse
|
4
|
Patel JC, Parveen S. In Vitro and In Vivo Analysis of Fentanyl and Fentalog Metabolites using Hyphenated Chromatographic Techniques: A Review. Chem Res Toxicol 2021; 35:30-42. [PMID: 34957817 DOI: 10.1021/acs.chemrestox.1c00225] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Fentanyl and fentanyl analogues (also called fentalogs) are used as medical prescriptions to treat pain for a long time. Apart from their pharmaceutical applications, they are misused immensely, causing the opioid crisis. Fentanyl and its analogues are produced in clandestine laboratories and sold over dark Web markets to different parts of the world, leading to a rise in the death rate due to drug overdose. This is because the users are unaware of the lethal effects of the newer forms of fentalogs. Unlike other drugs, these fentalogs cannot be detected easily, as very little data are available, and this is one of the major reasons for the risk of life-threatening poisoning or deaths. Hence, rigorous studies of these drugs and their possible metabolites are required. It is also necessary to develop techniques for the detection of minute traces of metabolites in biological fluids. This Review provides an overview of the application of hyphenated chromatographic techniques used to analyze multiple novel fentalogs, using in vivo and in vitro methods. The article focuses on the metabolites formed in phase I and phase II processes in biological specimens obtained in recent cases of drug abuse and overdose deaths that could be useful for the detection and differentiation of multiple fentalogs.
Collapse
Affiliation(s)
- Jayashree C Patel
- Department of Forensic Science, School of Sciences, Jain (Deemed-to-be University), Bengaluru 560027, Karnataka, India
| | - Suphiya Parveen
- Department of Life Science, School of Sciences, Jain (Deemed-to-be University), Bengaluru 560027, Karnataka, India
| |
Collapse
|
5
|
Novel Evaluation of Submandibular Salivary Gland Tissue for Use as an Alternative Postmortem Toxicology Specimen. Am J Forensic Med Pathol 2021; 42:328-334. [PMID: 34475318 DOI: 10.1097/paf.0000000000000708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
ABSTRACT The collection of blood and tissue provides an opportunity for an objective comparison of autopsy results. Occasionally, a viable tissue sample is not available during autopsy. Expanding upon collected tissues to include a tissue that is accessible, is a possible drug depot, and is amendable to various analytical techniques may complement information obtained from other specimens. Given its absorption of ions, nutrients, and likely drugs via its rich blood supply, we evaluated the use of submandibular salivary gland tissue as an alternative postmortem specimen. The submandibular salivary glands of 52 decedents were excised. The tissue was homogenized, extracted, and analyzed via liquid chromatography tandem mass spectrometry for 43 opioids and 5 nonopioids. Liquid chromatography tandem mass spectrometry salivary tissue results were compared with the decedent's blood results. Results revealed that opioids were detected in salivary gland tissue at a sensitivity and specificity of 94.4% and 94.1%, respectively. Nonopioid drugs were detected at a sensitivity and specificity of 88.2% and 100.0%, respectively. This study suggests a comparable correlation exists between salivary gland tissue and blood results for certain drugs. Further evaluation is warranted. To our knowledge, this is the first report of salivary gland tissue being used for postmortem toxicology testing in humans.
Collapse
|
6
|
Vincenti F, Montesano C, Pirau S, Gregori A, Di Rosa F, Curini R, Sergi M. Simultaneous Quantification of 25 Fentanyl Derivatives and Metabolites in Oral Fluid by Means of Microextraction on Packed Sorbent and LC-HRMS/MS Analysis. Molecules 2021; 26:molecules26195870. [PMID: 34641416 PMCID: PMC8512571 DOI: 10.3390/molecules26195870] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 09/22/2021] [Accepted: 09/24/2021] [Indexed: 11/16/2022] Open
Abstract
Fentanyl and fentalogs’ intake as drugs of abuse is experiencing a great increase in recent years. For this reason, there are more and more cases in which it is important to recognize and quantify these molecules and related metabolites in biological matrices. Oral fluid (OF) is often used to find out if a subject has recently used a psychoactive substance and if, therefore, the person is still under the effect of psychotropics. Given its difficulty in handling, good sample preparation and the development of instrumental methods for analysis are essential. In this work, an analytical method is proposed for the simultaneous determination of 25 analytes, including fentanyl, several derivatives and metabolites. OF was collected by means of passive drool; sample pretreatment was developed in order to be fast, simple and possibly semi-automated by exploiting microextraction on packed sorbent (MEPS). The analysis was performed by means of LC–HRMS/MS obtaining good identification and quantification of all the analytes in less than 10 min. The proposed method was fully validated according to the Scientific Working Group for Forensic Toxicology (SWGTOX) international guidelines. Good results were obtained in terms of recoveries, matrix effect and sensitivity, showing that this method could represent a useful tool in forensic toxicology. The presented method was successfully applied to the analysis of proficiency test samples.
Collapse
Affiliation(s)
- Flaminia Vincenti
- Department of Chemistry, Sapienza University of Rome, 00185 Rome, Italy; (F.V.); (S.P.); (R.C.)
- Department of Public Health and Infectious Disease, Sapienza University of Rome, 00185 Rome, Italy
| | - Camilla Montesano
- Department of Chemistry, Sapienza University of Rome, 00185 Rome, Italy; (F.V.); (S.P.); (R.C.)
- Correspondence: (C.M.); (M.S.); Tel.: +39-064-9913-559 (C.M.); +39-086-1266-949 (M.S.)
| | - Svetlana Pirau
- Department of Chemistry, Sapienza University of Rome, 00185 Rome, Italy; (F.V.); (S.P.); (R.C.)
| | - Adolfo Gregori
- Department of Scientific Investigation (RIS), Carabinieri, 00191 Rome, Italy; (A.G.); (F.D.R.)
| | - Fabiana Di Rosa
- Department of Scientific Investigation (RIS), Carabinieri, 00191 Rome, Italy; (A.G.); (F.D.R.)
| | - Roberta Curini
- Department of Chemistry, Sapienza University of Rome, 00185 Rome, Italy; (F.V.); (S.P.); (R.C.)
| | - Manuel Sergi
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy
- Correspondence: (C.M.); (M.S.); Tel.: +39-064-9913-559 (C.M.); +39-086-1266-949 (M.S.)
| |
Collapse
|
7
|
Alternative matrices in forensic toxicology: a critical review. Forensic Toxicol 2021; 40:1-18. [DOI: 10.1007/s11419-021-00596-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 06/19/2021] [Indexed: 12/12/2022]
Abstract
Abstract
Purpose
The use of alternative matrices in toxicological analyses has been on the rise in clinical and forensic settings. Specimens alternative to blood and urine are useful in providing additional information regarding drug exposure and analytical benefits. The goal of this paper is to present a critical review on the most recent literature regarding the application of six common alternative matrices, i.e., oral fluid, hair, sweat, meconium, breast milk and vitreous humor in forensic toxicology.
Methods
The recent literature have been searched and reviewed for the characteristics, advantages and limitations of oral fluid, hair, sweat, meconium, breast milk and vitreous humor and its applications in the analysis of traditional drugs of abuse and novel psychoactive substances (NPS).
Results
This paper outlines the properties of six biological matrices that have been used in forensic analyses, as alternatives to whole blood and urine specimens. Each of this matrix has benefits in regards to sampling, extraction, detection window, typical drug levels and other aspects. However, theses matrices have also limitations such as limited incorporation of drugs (according to physical–chemical properties), impossibility to correlate the concentrations for effects, low levels of xenobiotics and ultimately the need for more sensitive analysis. For more traditional drugs of abuse (e.g., cocaine and amphetamines), there are already data available on the detection in alternative matrices. However, data on the determination of emerging drugs such as the NPS in alternative biological matrices are more limited.
Conclusions
Alternative biological fluids are important specimens in forensic toxicology. These matrices have been increasingly reported over the years, and this dynamic will probably continue in the future, especially considering their inherent advantages and the possibility to be used when blood or urine are unavailable. However, one should be aware that these matrices have limitations and particular properties, and the findings obtained from the analysis of these specimens may vary according to the type of matrix. As a potential perspective in forensic toxicology, the topic of alternative matrices will be continuously explored, especially emphasizing NPS.
Collapse
|
8
|
Mahowald GK, Khaliq TP, Griggs D, O M, Flood JG, Uljon S. Comparison of Oral Fluid and Urine for Detection of Fentanyl Use Using Liquid Chromatography with Tandem Mass Spectrometry. J Appl Lab Med 2021; 6:1533-1540. [PMID: 34327523 DOI: 10.1093/jalm/jfab068] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 06/07/2021] [Indexed: 11/13/2022]
Abstract
BACKGROUND We compared oral fluid (OF) and urine (UR) for detection of fentanyl (FEN) use in addiction medicine-psychiatry (AMP) clinics. METHODS We measured FEN and norfentanyl (NRFEN) in UR with a limit of detection (LOD) of 2.0 µg/L and FEN in OF with an LOD of 0.5 µg/L by LC-MS/MS in 311 paired samples and compared the 2 matrices when higher OF and UR LODs were used. RESULTS Urine (UR) detected more FEN use than OF using a LOD of 2.0 µg/L and 0.5 µg/L, respectively. FEN and/or NRFEN were detected in 44 and 59 UR specimens, respectively, and FEN in 46 OF specimens (43 OF+UR+, 3 OF+UR-, 16 OF-UR+, and 249 OF-UR-). In UR there were no instances with FEN positive and NORFEN negative. UR creatinine was <20 mg/dL in the 3 OF+UR- specimen pairs. The median OF/UR analyte concentration ratios in positive sample pairs were 0.23 for OF FEN/UR FEN and 0.02 for OF FEN/UR NRFEN. CONCLUSIONS We demonstrate that UR detects more FEN use than OF in an AMP setting when UR FEN and UR NORFEN LODs of 2.0 µg/L are used. OF is less sensitive than UR in detecting FEN use, but is still valuable for cases with low UR creatinine and/or suspected adulteration or substitution of UR. The UR vs OF comparison statistics are greatly impacted by even minimal adjustments of the LOD.
Collapse
Affiliation(s)
- Grace K Mahowald
- Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, MA
| | - Tahira P Khaliq
- Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, MA
| | - David Griggs
- Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, MA
| | - Mi O
- Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, MA
| | - James G Flood
- Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, MA
| | - Sacha Uljon
- Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, MA
| |
Collapse
|
9
|
Palmquist KB, Swortwood MJ. Quantification of fentanyl analogs in oral fluid using LC-QTOF-MS. J Forensic Sci 2021; 66:1871-1878. [PMID: 34287912 DOI: 10.1111/1556-4029.14813] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 07/06/2021] [Accepted: 07/08/2021] [Indexed: 11/28/2022]
Abstract
Oral fluid is a valuable alternative matrix for forensic toxicologists due to ease of observed collection, limited biohazardous exposure, and indications of recent drug use. Limited information is available for fentanyl analog prevalence, interpretation, or analysis in oral fluid. With increasing numbers of fentanyl-related driving under the influence of drug (DUID) cases appearing in the United States, the development of detection methods is critical. The purpose of the present study was to develop and validate a quantitative method for fentanyl analogs in oral fluid (collected via Quantisal™) using liquid chromatography-quadrupole-time-of-flight-mass spectrometry (LC-QTOF-MS). Validation resulted in limits of detection and quantification ranging from 0.5 to 1 ng/mL. Established linear range was 1-100 ng/mL for all analytes, except acetyl fentanyl at 0.5-100 ng/mL (R2 > 0.994). Within- and between-run precision and bias were considered acceptable with maximum values of ±15.2%CV and ±14.1%, respectively. Matrix effects exhibited ionization enhancement for all analytes with intensified enhancement at a low concentration (9.3-47.4%). No interferences or carryover was observed. Fentanyl analogs were stable in processed extracts stored in the autosampler (4⁰ C) for 48h. The validated method was used to quantify fentanyl analogs in authentic oral fluid samples (n=17) from probationers/parolees. Fentanyl and 4-ANPP concentrations were 1.0-104.5 ng/mL and 1.2-5.7 ng/mL, respectively.
Collapse
Affiliation(s)
- Kaitlyn B Palmquist
- Department of Forensic Science, College of Criminal Justice, Sam Houston State University, Huntsville, TX, USA
| | - Madeleine J Swortwood
- Department of Forensic Science, College of Criminal Justice, Sam Houston State University, Huntsville, TX, USA
| |
Collapse
|
10
|
Krotulski AJ, Chapman BP, Marks SJ, Ontiveros ST, Devin-Holcombe K, Fogarty MF, Trieu H, Logan BK, Merchant RC, Babu KM. Sentanyl: a comparison of blood fentanyl concentrations and naloxone dosing after non-fatal overdose. Clin Toxicol (Phila) 2021; 60:197-204. [PMID: 34278904 DOI: 10.1080/15563650.2021.1948558] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Non-pharmaceutical fentanyl and its analogs have driven striking increases in opioid-associated overdose deaths. These highly potent opioids can be found at low concentrations in biological specimens. Little is known regarding the concentrations of these substances among survivors of non-fatal overdoses. In a locale where fentanyl is responsible for the majority of non-fatal opioid overdoses, we compared the concentration of fentanyl in blood to naloxone dosing in the presence and absence of a concurrent sedative-hypnotic exposure. METHODS In this pilot study, we enrolled adult patients presenting to the emergency department (ED) who: (1) arrived after an overdose requiring naloxone for the reversal of respiratory depression; and (2) who required venipuncture or intravenous access as part of their clinical care. Blood specimens (n = 20) underwent comprehensive toxicology testing, including the quantitation of fentanyl, fentanyl analogs, and naloxone, as well as the detection of common sedative-hypnotics and a wide range of other illicit and pharmaceutical substances. We then compared fentanyl concentrations to naloxone dosing in participants with and without a concomitant sedative-hypnotic exposure. RESULTS Nineteen of twenty participants (95%) were exposed to fentanyl prior to their overdose; the remaining participant tested positive for heroin metabolites. No participants reported pharmaceutical fentanyl use. Fentanyl analogs - acetylfentanyl or carfentanil - were present in three specimens. In 11 cases, fentanyl and its metabolites were the only opioids identified. Among the fentanyl-exposed, blood concentrations ranged from <0.1-19 ng/mL with a mean of 6.2 ng/mL and a median of 3.6 ng/mL. There was no relationship between fentanyl concentration and naloxone dose administered for reversal. We detected sedative-hypnotics (including benzodiazepines, muscle relaxants, and antidepressants) in nine participants. Among the sedative-hypnotic exposed, fentanyl concentrations were lower, but naloxone dosing was similar to those without a concomitant exposure. CONCLUSIONS In this study, we found that: 1) fentanyl was present in the blood of nearly all participants; 2) fentanyl concentrations were lower among study participants with concomitant sedative-hypnotic exposure; and 3) the dose of naloxone administered for overdose reversal was not associated with the measured fentanyl concentration in blood specimens. Our results underscore the role that tolerance and concomitant drug exposure play in the precipitation and resuscitation of management of opioid overdose.
Collapse
Affiliation(s)
- Alex J Krotulski
- Center for Forensic Science Research and Education, Fredric Rieders Family Foundation, Willow Grove, PA, USA.,College of Life Sciences, Thomas Jefferson University, Philadelphia, PA, USA
| | - Brittany P Chapman
- Department of Emergency Medicine, Division of Medical Toxicology, University of Massachusetts Medical School, Worcester, MA, USA
| | - Sarah J Marks
- Department of Emergency Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Sam T Ontiveros
- Department of Emergency Medicine, Division of Medical Toxicology, University of Massachusetts Medical School, Worcester, MA, USA
| | - Katharine Devin-Holcombe
- Department of Emergency Medicine, Division of Medical Toxicology, University of Massachusetts Medical School, Worcester, MA, USA
| | - Melissa F Fogarty
- Center for Forensic Science Research and Education, Fredric Rieders Family Foundation, Willow Grove, PA, USA
| | - Hai Trieu
- College of Life Sciences, Thomas Jefferson University, Philadelphia, PA, USA
| | - Barry K Logan
- Center for Forensic Science Research and Education, Fredric Rieders Family Foundation, Willow Grove, PA, USA.,College of Life Sciences, Thomas Jefferson University, Philadelphia, PA, USA.,Toxicology Department, NMS Labs, Horsham, PA, USA
| | - Roland C Merchant
- Department of Emergency Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Kavita M Babu
- Department of Emergency Medicine, Division of Medical Toxicology, University of Massachusetts Medical School, Worcester, MA, USA
| |
Collapse
|
11
|
Lei X, Xu X, Liu L, Kuang H, Xu L, Hao C, Xu C. Rapid quantitative determination of fentanyl in human urine and serum using a gold-based immunochromatographic strip sensor. J Mater Chem B 2021; 8:8573-8584. [PMID: 32814936 DOI: 10.1039/d0tb01509a] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Fentanyl is a typical opioid that is used in surgical anesthesia. However, when abused, fentanyl can lead to addiction and even death. To better control the use of fentanyl, it is necessary to develop rapid and sensitive detection methods. In this study, an ultrasensitive monoclonal antibody (mAb) was prepared and used to develop an indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) and a colloidal gold-based immunochromatographic strip (CG-ICS) for the analysis of fentanyl in urine and serum. Under optimum conditions, the anti-fentanyl mAb belonging to the subtype of IgG2b showed a half-maximal inhibitory concentration (IC50) of 0.11 ng mL-1 and a linear range of detection of 0.020-0.50 ng mL-1. Fenanyl-spiked original urine and serum diluted eight times were used for the analysis of fentanyl by ic-ELISA and CG-ICS. IC50 from the standard curves was 0.46 ng mL-1 for urine and 2.6 ng mL-1 for serum in ic-ELISA and 1.6 ng mL-1 for urine and 6.27 ng mL-1 for serum in CG-ICS. The recovery test revealed that the ic-ELISA and CG-ICS, with a recovery rate of 87.0-108.4% and a coefficient of variation of 3.3-10.9%, were the same reliable tools as the liquid chromatography tandem mass spectrometry for fentanyl analysis in real samples.
Collapse
Affiliation(s)
- Xianlu Lei
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China. and International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Xinxin Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China. and International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Liqiang Liu
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China. and International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Hua Kuang
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China. and International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Liguang Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China. and International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Changlong Hao
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China. and International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Chuanlai Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China. and International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| |
Collapse
|
12
|
Arantes ACF, da Cunha KF, Cardoso MS, Oliveira KD, Costa JL. Development and validation of quantitative analytical method for 50 drugs of antidepressants, benzodiazepines and opioids in oral fluid samples by liquid chromatography–tandem mass spectrometry. Forensic Toxicol 2020. [DOI: 10.1007/s11419-020-00561-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Abstract
Purpose
We developed and validated a method for quantitative analysis of 50 psychoactive substances and metabolites (antidepressants, benzodiazepines and opioids) in oral fluid samples using simple liquid–liquid extraction procedure followed by liquid chromatography–tandem mass spectrometry (LC–MS/MS).
Method
Oral fluid samples were collected using Quantisal™ device and extracted by liquid–liquid extraction with 1.0 mL of methyl tert-butyl ether and then analyzed using LC–MS/MS.
Results
The method attended method validation criteria, with limits of quantification as low as 0.5 and 1.0 ng/mL, and linearity between 0.5–50.0 ng/mL for antidepressants, 0.5–25.0 ng/mL for benzodiazepines and 1.0–50.0 ng/mL to opioids. During method validation, bias and imprecision values were not greater than 16 and 20%, respectively. Ionization suppression/enhancement bias results were not greater than 25%. No evidence of carryover was observed. Sample stability studies showed that almost all analytes were stable at 25 °C for 3 days and at 4 °C for 7 days. Freeze–thaw cycles stability showed that most antidepressants and opioids were stable under these conditions. Autosampler stability study showed that all analytes were stable for 24 h, except for nitrazepam and 7-aminoclonazepam. Thirty-eight authentic oral fluid samples were analyzed; 36.8% of the samples were positive for 2 drugs. Citalopram was the most common drug found, followed by venlafaxine.
Conclusions
The method was validated according to international recommendations for the 50 analytes, showing low limits of quantification, good imprecision and bias values, using simple liquid–liquid extraction, and was successfully applied to authentic oral fluid samples analysis.
Collapse
|
13
|
Kolesnikova TO, Shevyrin VA, Eltsov OS, Khatsko SL, Demin KA, Galstyan DS, de Abreu MS, Kalueff AV. Psychopharmacological characterization of an emerging drug of abuse, a synthetic opioid U-47700, in adult zebrafish. Brain Res Bull 2020; 167:48-55. [PMID: 33249261 DOI: 10.1016/j.brainresbull.2020.11.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 11/16/2020] [Accepted: 11/23/2020] [Indexed: 01/03/2023]
Abstract
3,4-Dichloro-N-[2-(dimethylamino)cyclohexyl]-N-methylbenzamide (U-47700) is a selective μ-opioid receptor agonist originally synthesized as a prospective analgesic drug. Several times more potent than morphine, U-47700 has high abuse potential and may cause clinical neurotoxicity, euphoria, respiratory depression and occasional mortality. U-47700 also evokes analgesia, sedation and euphoria-like states in both humans and rodents. Despite the growing use and abuse of U-47700, its psychopharmacological and toxicological profiles in vivo remain poorly understood. The zebrafish (Danio rerio) is rapidly becoming a popular aquatic model organism for central nervous system (CNS) disease modeling and drug discovery. Here, we examine acute (1, 5, 10, 25 and 50 mg/L for 20-min) and chronic (0.1, 0.5 and 1 mg/L for 14 days) effects of U-47700 in adult zebrafish. Overall, we found overt sedation evoked in fish by acute, and hyperlocomotion with an anxiolytic-like action by chronic, drug treatments. Acute treatment with 1 and 10 mg/L U-47700 also resulted in detectable amounts of this drug in the brain samples, supporting its permeability through the blood-brain barrier. Collectively, these findings emphasize complex dose- and treatment-dependent CNS effects of U-47700 following its acute and chronic administration. Our study also supports high sensitivity of zebrafish to U-47700, and suggests these aquatic models as promising in-vivo screens for probing potential CNS effects evoked by novel synthetic opioid drugs.
Collapse
Affiliation(s)
- Tatiana O Kolesnikova
- Ural Federal University, Ekaterinburg, Russia; Institute of Experimental Medicine, Almazov National Medical Research Center, Ministry of Healthcare of Russian Federation, St. Petersburg, Russia; Laboratory of Biological Psychiatry, Institute of Translational Biomedicine, St. Petersburg State University, St. Petersburg, Russia
| | | | | | | | - Konstantin A Demin
- Institute of Experimental Medicine, Almazov National Medical Research Center, Ministry of Healthcare of Russian Federation, St. Petersburg, Russia; Laboratory of Biological Psychiatry, Institute of Translational Biomedicine, St. Petersburg State University, St. Petersburg, Russia
| | - David S Galstyan
- Granov Scientific Research Center of Radiology and Surgical Technologies, Ministry of Healthcare of Russian Federation, St. Petersburg, Russia
| | - Murilo S de Abreu
- Bioscience Institute, University of Passo Fundo, Passo Fundo, Brazil; Laboratory of Cell and Molecular Biology and Neurobiology, Moscow Institute of Physics and Technology, Dolgoprudny, Russia
| | - Allan V Kalueff
- School of Pharmacy, Southwest University, Chongqing, China; Laboratory of Petrochemistry, Ural Federal University, Ekaterinburg, Russia.
| |
Collapse
|
14
|
Baumann MH, Tocco G, Papsun DM, Mohr AL, Fogarty MF, Krotulski AJ. U-47700 and Its Analogs: Non-Fentanyl Synthetic Opioids Impacting the Recreational Drug Market. Brain Sci 2020; 10:E895. [PMID: 33238449 PMCID: PMC7700279 DOI: 10.3390/brainsci10110895] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 11/16/2020] [Accepted: 11/18/2020] [Indexed: 11/17/2022] Open
Abstract
The recreational use of opioid drugs is a global threat to public health and safety. In particular, an epidemic of opioid overdose fatalities is being driven by illicitly manufactured fentanyl, while novel synthetic opioids (NSOs) are appearing on recreational drug markets as standalone products, adulterants in heroin, or ingredients in counterfeit drug preparations. Trans-3,4-dichloro-N-[2-(dimethylamino)cyclohexyl]-N-methylbenzamide (U-47700) is a prime example of a non-fentanyl NSO that is associated with numerous intoxications and fatalities. Here, we review the medicinal chemistry, preclinical pharmacology, clandestine availability, methods for detection, and forensic toxicology of U-47700 and its analogs. An up-to-date summary of the human cases involving U-47700 intoxication and death are described. The evidence demonstrates that U-47700 is a potent μ-opioid receptor agonist, which poses a serious risk for overdosing and death. However, most analogs of U-47700 appear to be less potent and have been detected infrequently in forensic specimens. U-47700 represents a classic example of how chemical entities from the medicinal chemistry or patent literature can be diverted for use in recreational drug markets. Lessons learned from the experiences with U-47700 can inform scientists, clinicians, and policymakers who are involved with responding to the spread and impact of NSOs.
Collapse
Affiliation(s)
- Michael H. Baumann
- Designer Drug Research Unit, Intramural Research Program, National Institute on Drug Abuse, National Institutes of Health, 333 Cassell Drive, Suite 4400, Baltimore, MD 21224, USA
| | - Graziella Tocco
- Department of Life and Environmental Sciences, University of Cagliari, Cittadella Universitaria di Monserrato, Monserrato, 09042 Cagliari, Italy;
| | - Donna M. Papsun
- Toxicology Department, NMS Labs, 200 Welsh Road, Horsham, PA 19044, USA;
| | - Amanda L. Mohr
- Center for Forensic Science Research and Education, Fredric Rieders Family Foundation, 2300 Stratford Ave, Willow Grove, 19090 PA, USA; (A.L.M.); (M.F.F.); (A.J.K.)
| | - Melissa F. Fogarty
- Center for Forensic Science Research and Education, Fredric Rieders Family Foundation, 2300 Stratford Ave, Willow Grove, 19090 PA, USA; (A.L.M.); (M.F.F.); (A.J.K.)
| | - Alex J. Krotulski
- Center for Forensic Science Research and Education, Fredric Rieders Family Foundation, 2300 Stratford Ave, Willow Grove, 19090 PA, USA; (A.L.M.); (M.F.F.); (A.J.K.)
| |
Collapse
|
15
|
Danaceau JP, Wood M, Ehlers M, Rosano TG. Analysis of 17 fentanyls in plasma and blood by UPLC-MS/MS with interpretation of findings in surgical and postmortem casework. CLINICAL MASS SPECTROMETRY (DEL MAR, CALIF.) 2020; 18:38-47. [PMID: 34820524 PMCID: PMC8601016 DOI: 10.1016/j.clinms.2020.10.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 10/21/2020] [Accepted: 10/23/2020] [Indexed: 11/17/2022]
Abstract
The opioid crisis is linked to an increased misuse of fentanyl as well as fentanyl analogs that originate from the illicit drug market. Much of our current understanding of fentanyl and fentanyl analog use in our communities comes from postmortem toxicology findings. In the clinical settings of addiction medicine and pain management, where the opioid abuse potential is high, the use of fentanyl, as well as specific fentanyl analogs, may be underestimated due to limited plasma testing and limited availability of assays with suitable analytical sensitivity and selectivity to detect misuse of fentanyls. We report plasma and blood assays for 17 fentanyls (these include fentanyl, fentanyl analogs, fentanyl metabolites and synthetic precursors) in clinical, and medical examiner, casework. A mixed-mode solid phase extraction of diluted plasma or precipitated blood was optimized for maximum recovery of the fentanyls with minimized matrix effects. Analysis was performed using a Waters ACQUITY UPLC I-Class interfaced with a Waters Xevo TQ-S micro tandem quadrupole mass spectrometer. Method parameters were optimized and validated for precision, accuracy, carryover, linearity and matrix effects. Application studies were performed in postmortem blood obtained in 44 fentanyl-related fatalities and in serial plasma samples from 18 surgical patients receiving intravenous fentanyl therapy while undergoing parathyroidectomy. Fentanyls found in postmortem cases included fentanyl, norfentanyl, despropionyl-fentanyl (4-ANPP), beta-hydroxy fentanyl (β-OH fentanyl), acetyl fentanyl, acetyl norfentanyl, methoxyacetyl fentanyl, furanyl fentanyl, cyclopropyl fentanyl, and para-fluorobutyryl fentanyl, with fentanyl, norfentanyl, 4-ANPP and β-OH fentanyl predominating in frequency. Fentanyl concentrations ranged from 0.2 to 56 ng/mL and fentanyl was nearly always found with 4-ANPP, norfentanyl and β-OH fentanyl. Concentrations of other fentalogs ranged from <1 to 84 ng/mL (extrapolated). In the surgical cases, fentanyl was detected and quantified along with norfentanyl and β-OH fentanyl, but without detection of 4-ANPP in any of the samples. The association and relative concentrations of β-OH fentanyl, fentanyl and norfentanyl in the postmortem and clinical studies indicated a metabolic, rather than an illicit, source of β-OH fentanyl.
Collapse
Affiliation(s)
| | | | | | - Thomas G Rosano
- Albany Medical Center (AMC), Albany, NY, USA
- National Toxicology Center, Albany NY, USA
| |
Collapse
|
16
|
Affiliation(s)
- Samuel A. Krug
- Forensic Science Arcadia University Glenside Pennsylvania USA
| | - Karen S. Scott
- Forensic Science Arcadia University Glenside Pennsylvania USA
| |
Collapse
|
17
|
Abstract
U-47700, 3,4-dichloro-N-((1R,2R)-2-(dimethylamino)cyclohexyl)-N-methyl benzamide, is a novel synthetic opioid (NSO), discovered by the Upjohn company in the late 1970s. With potent in vivo activity, ∼10-times greater than that of morphine, U-47700 has become a drug of widespread abuse due to its ease of synthesis and, until recently, lack of robust detection methods by law enforcement. U-47700 has been found in counterfeit oxycodone tablets and is a key ingredient in "gray death." Due to its emergence worldwide in the past 5 years, it is now a Schedule I drug in the United States and similarly designated around the world; moreover, at autopsy, U-47700 was found to have contributed to the death of the pop artist Prince. This Review will capture the >40 year history of U-47700 and go in-depth regarding the synthesis, medicinal chemistry, in vitro/in vivo pharmacology, drug metabolism (from postmortem overdose cases), and societal impact of this DARK Classic in chemical neuroscience.
Collapse
Affiliation(s)
- Kwaku Kyei-Baffour
- Warren Center for Neuroscience Drug Discovery, Vanderbilt University School of Medicine, Nashville, Tennessee 37232, United States
- Department of Pharmacology, Vanderbilt University School of Medicine, Nashville, Tennessee 37232, United States
| | - Craig W. Lindsley
- Warren Center for Neuroscience Drug Discovery, Vanderbilt University School of Medicine, Nashville, Tennessee 37232, United States
- Department of Pharmacology, Vanderbilt University School of Medicine, Nashville, Tennessee 37232, United States
- Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt University, Nashville, Tennessee 37232, United States
- Department of Biochemistry, Vanderbilt University School of Medicine, Nashville, Tennessee 37232, United States
| |
Collapse
|
18
|
Abstract
This paper is the fortieth consecutive installment of the annual anthological review of research concerning the endogenous opioid system, summarizing articles published during 2017 that studied the behavioral effects of molecular, pharmacological and genetic manipulation of opioid peptides and receptors as well as effects of opioid/opiate agonists and antagonists. The review is subdivided into the following specific topics: molecular-biochemical effects and neurochemical localization studies of endogenous opioids and their receptors (1), the roles of these opioid peptides and receptors in pain and analgesia in animals (2) and humans (3), opioid-sensitive and opioid-insensitive effects of nonopioid analgesics (4), opioid peptide and receptor involvement in tolerance and dependence (5), stress and social status (6), learning and memory (7), eating and drinking (8), drug abuse and alcohol (9), sexual activity and hormones, pregnancy, development and endocrinology (10), mental illness and mood (11), seizures and neurologic disorders (12), electrical-related activity and neurophysiology (13), general activity and locomotion (14), gastrointestinal, renal and hepatic functions (15), cardiovascular responses (16), respiration and thermoregulation (17), and immunological responses (18).
Collapse
Affiliation(s)
- Richard J Bodnar
- Department of Psychology and Neuropsychology Doctoral Sub-Program, Queens College, City University of New York, CUNY, 65-30 Kissena Blvd., Flushing, NY, 11367, United States.
| |
Collapse
|
19
|
The rising crisis of illicit fentanyl use, overdose, and potential therapeutic strategies. Transl Psychiatry 2019; 9:282. [PMID: 31712552 PMCID: PMC6848196 DOI: 10.1038/s41398-019-0625-0] [Citation(s) in RCA: 88] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Revised: 10/10/2019] [Accepted: 10/20/2019] [Indexed: 12/11/2022] Open
Abstract
Fentanyl is a powerful opioid anesthetic and analgesic, the use of which has caused an increasing public health threat in the United States and elsewhere. Fentanyl was initially approved and used for the treatment of moderate to severe pain, especially cancer pain. However, recent years have seen a growing concern that fentanyl and its analogs are widely synthesized in laboratories and adulterated with illicit supplies of heroin, cocaine, methamphetamine, and counterfeit pills, contributing to the exponential growth in the number of drug-related overdose deaths. This review summarizes the recent epidemic and evolution of illicit fentanyl use, its pharmacological mechanisms and side effects, and the potential clinical management and prevention of fentanyl-related overdoses. Because social, economic, and health problems that are related to the use of fentanyl and its analogs are growing, there is an urgent need to implement large-scale safe and effective harm reduction strategies to prevent fentanyl-related overdoses.
Collapse
|
20
|
Truver MT, Palmquist KB, Swortwood MJ. Oral Fluid and Drug Impairment: Pairing Toxicology with Drug Recognition Expert Observations. J Anal Toxicol 2019; 43:637-643. [PMID: 31504595 DOI: 10.1093/jat/bkz075] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 05/09/2019] [Accepted: 07/18/2019] [Indexed: 11/14/2022] Open
Abstract
According to the Governors Highway Safety Association, drugs are detected more frequently in fatally injured drivers than alcohol. Due to the variety of drugs (prescribed and/or illicit) and their various physiological effects on the body, it is difficult for law enforcement to detect/prosecute drug impairment. While blood and urine are typical biological specimens used to test for drugs, oral fluid is an attractive alternative matrix. Drugs are incorporated into oral fluid by oral contamination (chewing or smoking) or from the bloodstream. Oral fluid is non-invasive and easy to collect without the need for a trained professional to obtain the sample, unlike urine or blood. This study analyzes paired oral fluid and urine with drug recognition expert (DRE) observations. Authentic oral fluid samples (n = 20) were collected via Quantisal™ devices from arrestees under an institutional review board-approved protocol. Urine samples (n = 18) were collected with EZ-SCREEN® cups that presumptively screened for Δ9-tetrahydrocannabinol (cannabinoids), opiates, methamphetamine, cocaine, methadone, phencyclidine, amphetamine, benzodiazepines and oxycodone. Impairment observations (n = 18) were recorded from officers undergoing DRE certification. Oral fluid samples were screened using an Agilent Technologies 1290 Infinity liquid chromatograph (LC) coupled to an Agilent Technologies 6530 Accurate Mass Time-of-Flight mass spectrometer (MS). Personal compound and database libraries were produced in-house containing 64 drugs of abuse. An Agilent 1290 Infinity LC system equipped with an Agilent 6470 Triple Quadrupole MS was used for quantification of buprenorphine, heroin markers (6-acetylmorphine, morphine) and synthetic opioids. Subjects were 23-54 years old; 11 (55%) were male and 9 (45%) were female. Evaluator opinion of drug class was confirmed in oral fluid 90% of time and in urine 85% of the time in reference to scope of testing by the LC-MS methods employed (excludes cannabis and central nervous system depressants). Data indicate that oral fluid may be a viable source for confirming driving under the influence of drugs.
Collapse
Affiliation(s)
- Michael T Truver
- Department of Forensic Science, College of Criminal Justice, Sam Houston State University, 1003 Bowers Blvd, Huntsville, Texas, USA
| | - Kaitlyn B Palmquist
- Department of Forensic Science, College of Criminal Justice, Sam Houston State University, 1003 Bowers Blvd, Huntsville, Texas, USA
| | - Madeleine J Swortwood
- Department of Forensic Science, College of Criminal Justice, Sam Houston State University, 1003 Bowers Blvd, Huntsville, Texas, USA
| |
Collapse
|
21
|
Quadrupole Time-of-Flight Mass Spectrometry: A Paradigm Shift in Toxicology Screening Applications. Clin Biochem Rev 2019; 40:135-146. [PMID: 31530964 DOI: 10.33176/aacb-19-00023] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The screening of biological samples for the presence of illicit or legal substances is an important frontline tool in both clinical and forensic toxicology. In the clinical setting, drug screening is a useful tool for the clinician in improving patient care and guiding treatment. Analytical approaches for the screening of drugs in biological samples are extensive and well documented, though many rapid screening techniques often lack appropriate sensitivity and specificity, requiring careful clinical interpretation. The continuous emergence of new psychoactive substances presents a considerable analytical challenge in maintaining up-to-date methods for the detection of relevant drugs. Adapting and validating methods for the detection of new substances can be a complicated and costly undertaking. There is also a considerable lag time between the emergence of new drugs and the release of commercial assays for detection. Quadrupole time-of-flight mass spectrometry (Q-TOF-MS) has gained considerable attention over the last decade as an analytical technique that is capable of meeting the challenges of a rapidly changing drug landscape. Exhibiting both high sensitivity and specificity in drug detection, Q-TOF-MS also allows methods to be rapidly updated for newly emerging psychoactive agents. The coupling of Q-TOF-MS with techniques such as liquid or gas chromatography can provide both rapid and comprehensive screening solutions that are gaining popularity in the clinical laboratory setting.
Collapse
|
22
|
Chromatographic separation of the isobaric compounds cyclopropylfentanyl, crotonylfentanyl, methacrylfentanyl, and para-methylacrylfentanyl for specific confirmation by LC-MS/MS. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1118-1119:164-170. [DOI: 10.1016/j.jchromb.2019.04.033] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 04/12/2019] [Accepted: 04/15/2019] [Indexed: 11/19/2022]
|
23
|
Chiu SK, Hornsby‐Myers JL, Perio MA, Snawder JE, Wiegand DM, Trout D, Howard J. Health effects from unintentional occupational exposure to opioids among law enforcement officers: Two case investigations. Am J Ind Med 2019; 62:439-447. [PMID: 31016761 DOI: 10.1002/ajim.22967] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Revised: 01/28/2019] [Accepted: 02/19/2019] [Indexed: 12/23/2022]
Abstract
Recent increases in the rate of drug overdose-related deaths, the emergence of potent opioids such as carfentanil, and media reports of incidents have raised concerns about the potential for work-related exposure to a variety of illicit drugs among law enforcement officers (LEOs), other emergency responders, and other workers in the United States. To characterize the risk associated with unintentional occupational exposure to drugs, we retrospectively investigated two incidents that occurred in 2017 and 2018 where LEOs were exposed to opioid and stimulant drugs and experienced health effects. We interviewed five affected LEOs and others. We reviewed records, including emergency department documentation, incident reports, forensic laboratory results, and when available, body camera footage. Multiple drug types, including opioids and nonopioids, were present at each incident. Potential routes of exposure varied among LEOs and were difficult to characterize with certainty. Health effects were not consistent with severe, life-threatening opioid toxicity, but temporarily precluded affected LEOs from performing their essential job duties. While health risks from occupational exposure to drugs during law enforcement activities cannot currently be fully characterized with certainty, steps to prevent such exposures should be implemented now. The creation and implementation of appropriate controls plus education and training are both important to protecting first responders from these hazardous agents. To more fully characterize potential exposures, timely prospective toxicological evaluation of affected responders is recommended.
Collapse
Affiliation(s)
- Sophia K. Chiu
- National Institute for Occupational Safety and Health, Division of Surveillance, Hazard Evaluations and Field StudiesCincinnati Ohio
| | - Jennifer L. Hornsby‐Myers
- National Institute for Occupational Safety and Health, Office of the Director, Emergency Preparedness and Response OfficeMorgantown West Virginia
| | - Marie A. Perio
- National Institute for Occupational Safety and Health, Division of Surveillance, Hazard Evaluations and Field StudiesCincinnati Ohio
| | - John E. Snawder
- National Institute for Occupational Safety and Health, Division of Applied Research and TechnologyCincinnati Ohio
| | - Douglas M. Wiegand
- National Institute for Occupational Safety and Health, Division of Surveillance, Hazard Evaluations and Field StudiesCincinnati Ohio
| | - Douglas Trout
- National Institute for Occupational Safety and Health, Division of Surveillance, Hazard Evaluations and Field StudiesCincinnati Ohio
| | - John Howard
- National Institute for Occupational Safety and Health, Office of the DirectorWashington District of Columbia
| |
Collapse
|
24
|
Van Wijk XMR, Goodnough R, Colby JM. Mass spectrometry in emergency toxicology: Current state and future applications. Crit Rev Clin Lab Sci 2019; 56:225-238. [DOI: 10.1080/10408363.2019.1585415] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Affiliation(s)
- Xander M. R. Van Wijk
- Department of Pathology, Pritzker School of Medicine, University of Chicago, Chicago, IL, US
| | - Robert Goodnough
- California Poison Control System, San Francisco Division, San Francisco, CA, US
- Department of Emergency Medicine, University of California San Francisco, San Francisco, CA, US
| | - Jennifer M. Colby
- Department of Pathology, Microbiology and Immunology, Vanderbilt University School of Medicine, Nashville, TN, US
| |
Collapse
|
25
|
Palmquist KB, Swortwood MJ. Data-independent screening method for 14 fentanyl analogs in whole blood and oral fluid using LC-QTOF-MS. Forensic Sci Int 2019; 297:189-197. [DOI: 10.1016/j.forsciint.2019.02.006] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Revised: 01/28/2019] [Accepted: 02/04/2019] [Indexed: 11/28/2022]
|
26
|
Quantification of U-47700 and its metabolites: N-desmethyl-U-47700 and N,N-didesmethyl-U-47700 in 12 autopsy blood samples employing SPE/LC–ESI-MS-MS. Forensic Toxicol 2019. [DOI: 10.1007/s11419-019-00464-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
27
|
Reinstadler V, Lierheimer S, Boettcher M, Oberacher H. A validated workflow for drug detection in oral fluid by non-targeted liquid chromatography-tandem mass spectrometry. Anal Bioanal Chem 2019; 411:867-876. [PMID: 30519959 PMCID: PMC6338695 DOI: 10.1007/s00216-018-1504-x] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 11/05/2018] [Accepted: 11/19/2018] [Indexed: 12/16/2022]
Abstract
Oral fluid is recognized as an important specimen for drug testing. Common applications are monitoring in substance abuse treatment programs, therapeutic drug monitoring, pain management, workplace drug testing, clinical toxicology, and driving under the influence of drugs (DRUID). In this study, we demonstrate that non-targeted LC-MS/MS with subsequent compound identification by tandem mass spectral library search is a valuable tool for comprehensive detection and confirmation of drugs in oral fluid samples. The workflow developed involves solid-phase extraction and chromatographic separation on reversed phase materials. Mass spectrometric detection is accomplished on a quadrupole-quadrupole-time-of-flight instrument operated with data-dependent acquisition control. The workflow was optimized for 500 μl of neat oral fluid collected with the Greiner Bio-One saliva collection system. The fitness of the developed method was tested and proven by analyzing blank and spiked samples as well as 59 authentic patient samples. We could demonstrate that compounds with logP values in the range 0.5-5.5 are efficiently detected at low nanograms per milliliter concentrations. The true positive and true negative rates of automated library search were equal or close to 100%. The beauty of the non-targeted LC-MS/MS approach is the ability to detect compounds hardly included in routinely applied targeted assays, and this was demonstrated by detecting the synthetic opioid U-47700 in two patient samples. Graphical abstract ᅟ.
Collapse
Affiliation(s)
- Vera Reinstadler
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Muellerstr. 44, 6020, Innsbruck, Austria
| | - Stefan Lierheimer
- MVZ Labor Dessau GmbH, Bauhüttenstr. 6, 06847, Dessau-Roßlau, Germany
| | - Michael Boettcher
- MVZ Labor Dessau GmbH, Bauhüttenstr. 6, 06847, Dessau-Roßlau, Germany
| | - Herbert Oberacher
- Institute of Legal Medicine and Core Facility Metabolomics, Medical University of Innsbruck, Muellerstr. 44, 6020, Innsbruck, Austria.
| |
Collapse
|
28
|
Roda G, Faggiani F, Bolchi C, Pallavicini M, Dei Cas M. Ten Years of Fentanyl-like Drugs: a Technical-analytical Review. ANAL SCI 2019; 35:479-491. [PMID: 30686797 DOI: 10.2116/analsci.18r004] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Synthetic opioids, such as fentanyl and its analogues, are a new public health warning. Clandestine laboratories produce drug analogues at a faster rate than these compounds can be controlled or scheduled by drug agencies. Detection requires specific testing and clinicians may be confronted with a sequence of severe issues concerning the diagnosis and management of these contemporary opioid overdoses. This paper deals with methods for biological sample treatment, as well as the methodologies of analysis that have been reported, in the last decade, in the field of fentanyl-like compounds. From this analysis, it emerges that the gold standard for the identification and quantification of 4-anilinopiperidines is LC-MS/MS, coupled with liquid-liquid or solid-phase extraction. In the end, the return to the scene of illicit fentanyls can be considered as a critical problem that can be tackled only with a global multidisciplinary approach.
Collapse
Affiliation(s)
- Gabriella Roda
- Department of Pharmaceutical Sciences, University of Milan
| | | | | | | | | |
Collapse
|
29
|
Truver MT, Swortwood MJ. Quantitative Analysis of Novel Synthetic Opioids, Morphine and Buprenorphine in Oral Fluid by LC–MS-MS. J Anal Toxicol 2018; 42:554-561. [DOI: 10.1093/jat/bky053] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Accepted: 07/16/2018] [Indexed: 11/14/2022] Open
Affiliation(s)
- Michael T Truver
- Department of Forensic Science, Sam Houston State University, 1003 Bowers Blvd., Huntsville, TX, USA
| | - Madeleine J Swortwood
- Department of Forensic Science, Sam Houston State University, 1003 Bowers Blvd., Huntsville, TX, USA
| |
Collapse
|