Roy A, Khanna P, Chowdhury SR, Haritha D, Sarkar S. The Impact of High-flow Nasal Cannula vs Other Oxygen Delivery Devices during Bronchoscopy under Sedation: A Systematic Review and Meta-analyses.
Indian J Crit Care Med 2022;
26:1131-1140. [PMID:
36876212 PMCID:
PMC9983664 DOI:
10.5005/jp-journals-10071-24339]
[Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 09/12/2022] [Indexed: 11/23/2022] Open
Abstract
Background
The widespread diagnostic and therapeutic application of bronchoscopy is often associated with complications like desaturation. This systematic review and meta-analysis intend to scrutinize whether the high-flow nasal cannula (HFNC) is advantageous for providing respiratory support during bronchoscopic procedures under sedation, in comparison with other conventional modalities for oxygen therapy.
Materials and methods
A thorough screening of electronic databases was done till 31st December 2021 after obtaining registration in PROSPERO (CRD42021245420). Randomized controlled trials (RCT), evaluating the impact of HFNC and standard/any other oxygen-delivery devices during bronchoscopy were included in this meta-analysis.
Results
We retrieved in nine RCTs, with a total of 1306 patients, the application of HFNC during bronchoscopy led to decreased number of desaturation spells [relative risk (RR) 0.34, 95% confidence interval (CI) 0.27-0.44, I 2 = 23%], higher nadir value of SpO2 [Mean difference (MD) 4.30, 95% CI 2.41-6.19, I 2 = 96%], and improved PaO2 from baseline (MD 21.77, 95% CI 2.8-40.74, I 2 = 99%), along with similar PaCO2 values (MD -0.34, 95% CI -1.82 to 1.13, I 2 = 58%) just after the procedure. However, apart from desaturation spell, the findings are significantly heterogeneous. In subgroup analysis, HFNC had significantly lesser desaturation spells and better oxygenation than low-flow devices, but in comparison to noninvasive ventilation (NIV) had a lower nadir value of SpO2 with no other significant difference.
Conclusion
High-flow nasal cannula led to greater oxygenation and prevented desaturation spells more effectively in comparison with low-flow devices like nasal cannula, venturi mask, etc., and may be considered as an alternative to NIV during bronchoscopy in certain high-risk patients.
How to cite this article
Roy A, Khanna P, Chowdhury SR, Haritha D, Sarkar S. The Impact of High-flow Nasal Cannula vs Other Oxygen Delivery Devices during Bronchoscopy under Sedation: A Systematic Review and Meta-analyses. Indian J Crit Care Med 2022;26(10):1131-1140.
Collapse