1
|
Segura PA, Guillaumain C, Eysseric E, Boudrias J, Moreau M, Guérette C, Clémencin R, Beaudry F. Ultrafast analysis of peptides by laser diode thermal desorption-triple quadrupole mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9373. [PMID: 35933590 DOI: 10.1002/rcm.9373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 08/05/2022] [Accepted: 08/06/2022] [Indexed: 06/15/2023]
Abstract
RATIONALE The COVID-19 pandemic demonstrated the importance of high-throughput analysis for public health. Given the importance of surface viral proteins for interactions with healthy tissue, they are targets of interest for mass spectrometry-based analysis. For that reason, the possibility of detecting and quantifying peptides using a high-throughput technique, laser diode thermal desorption-triple quadrupole mass spectrometry (LDTD-QqQMS), was explored. METHODS Two peptides used as models for small peptides (leu-enkephalin and endomorphin-2) and four tryptic peptides (GVYYPDK, NIDGYFK, IADYNYK, and QIAPGQTGK) specific to the SARS-CoV-2 Spike protein were employed. Target peptides were analyzed individually in the positive mode by LDTD-QqQMS. Peptides were quantified by internal calibration using selected reaction monitoring transitions in pure solvents and in samples spiked with 20 μg mL-1 of a bovine serum albumin tryptic digest to represent real analysis conditions. RESULTS Low-energy fragment ions (b and y ions) as well as high-energy fragment ions (c and x ions) and some of their corresponding water or ammonia losses were detected in the full mass spectra. Only for the smallest peptides, leu-enkephalin and endomorphin-2, were [M + H]+ ions observed. Product ion spectra confirmed that, with the experimental conditions used in the present study, LDTD transfers a considerable amount of energy to the target peptides. Quantitative analysis showed that it was possible to quantify peptides using LDTD-QqQMS with acceptable calibration curve linearity (R2 > 0.99), precision (RSD < 18.2%), and trueness (bias < 8.3%). CONCLUSIONS This study demonstrated for the first time that linear peptides can be qualitatively and quantitatively analyzed using LDTD-QqQMS. Limits of quantification and dynamic ranges are still inadequate for clinical applications, but other applications where higher levels of proteins must be detected could be possible with LDTD. Given the high-throughput capabilities of LDTD-QqQMS (>15 000 samples in less than 43 h), more studies are needed to improve the sensitivity for peptide analysis of this technique.
Collapse
Affiliation(s)
- Pedro A Segura
- Department of Chemistry, Faculty of Sciences, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - Cédric Guillaumain
- Department of Chemistry, Faculty of Sciences, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - Emmanuel Eysseric
- Department of Chemistry, Faculty of Sciences, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - Judith Boudrias
- Department of Chemistry, Faculty of Sciences, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - Mégane Moreau
- Department of Chemistry, Faculty of Sciences, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - Cassandra Guérette
- Department of Chemistry, Faculty of Sciences, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - Rémi Clémencin
- Department of Chemistry, Faculty of Sciences, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - Francis Beaudry
- Département de Biomédecine Vétérinaire, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, QC, Canada
- Centre de recherche sur le cerveau et l'apprentissage (CIRCA), Université de Montréal, Montréal, QC, Canada
| |
Collapse
|
2
|
Panda D, Dash BP, Manickam S, Boczkaj G. Recent advancements in LC-MS based analysis of biotoxins: Present and future challenges. MASS SPECTROMETRY REVIEWS 2022; 41:766-803. [PMID: 33624883 DOI: 10.1002/mas.21689] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 02/03/2021] [Accepted: 02/05/2021] [Indexed: 06/12/2023]
Abstract
There has been a rising concern regarding the harmful impact of biotoxins, source of origin, and the determination of the specific type of toxin. With numerous reports on their extensive spread, biotoxins pose a critical challenge to figure out their parent groups, metabolites, and concentration. In that aspect, liquid chromatography-mass spectrometry (LC-MS) based analysis paves the way for its accurate identification and quantification. The biotoxins are ideally categorized as phytotoxins, mycotoxins, shellfish-toxins, ciguatoxins, cyanotoxins, and bacterial toxins such as tetrodotoxins. Considering the diverse nature of biotoxins, both low-resolution mass spectrometry (LRMS) and high-resolution mass spectrometry (HRMS) methods have been implemented for their detection. The sample preparation strategy for complex matrix usually includes "QuEChERS" extraction or solid-phase extraction coupled with homogenization and centrifugation. For targeted analysis of biotoxins, the LRMS consisting of a tandem mass spectrometer operating in multiple reaction monitoring mode has been widely implemented. With the help of the reference standard, most of the toxins were accurately quantified. At the same time, the suspect screening and nontarget screening approach are facilitated by the HRMS platforms during the absence of reference standards. Significant progress has also been made in sampling device employment, utilizing novel sample preparation strategies, synthesizing toxin standards, employing hybrid MS platforms, and the associated data interpretation. This critical review attempts to elucidate the progress in LC-MS based analysis in the determination of biotoxins while pointing out major challenges and suggestions for future development.
Collapse
Affiliation(s)
- Debabrata Panda
- Center of Excellence (CoE), Fakir Mohan University, Nuapadhi, Odisha, India
| | - Bisnu P Dash
- Department of Bioscience and Biotechnology, Fakir Mohan University, Nuapadhi, Odisha, India
| | - Sivakumar Manickam
- Petroleum and Chemical Engineering, Faculty of Engineering, Universiti Teknologi Brunei, Bandar Seri Begawan, Brunei Darussalam
| | - Grzegorz Boczkaj
- Department of Process Engineering and Chemical Technology, Faculty of Chemistry, Gdansk University of Technology, Gdańsk, Poland
| |
Collapse
|
3
|
Bouteiller P, Lance E, Guérin T, Biré R. Analysis of Total-Forms of Cyanotoxins Microcystins in Biological Matrices: A Methodological Review. Toxins (Basel) 2022; 14:toxins14080550. [PMID: 36006212 PMCID: PMC9416067 DOI: 10.3390/toxins14080550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 07/22/2022] [Accepted: 08/09/2022] [Indexed: 11/16/2022] Open
Abstract
Microcystins (MCs) are cyclic heptapeptidic toxins produced by many cyanobacteria. Microcystins can be accumulated in various matrices in two forms: a free cellular fraction and a covalently protein-bound form. To detect and quantify the concentration of microcystins, a panel of techniques on various matrices (water, sediments, and animal tissues) is available. The analysis of MCs can concern the free or the total (free plus covalently bound) fractions. Free-form analyses of MCs are the most common and easiest to detect, whereas total-form analyses are much less frequent and more complex to achieve. The objective of this review is to summarize the different methods of extraction and analysis that have been developed for total forms. Four extraction methods were identified: MMPB (2-methyl-3-methoxy-4-phenylbutyric acid) method, deconjugation at basic pH, ozonolysis, and laser irradiation desorption. The study of the bibliography on the methods of extraction and analysis of the total forms of MCs showed that the reference method for the subject remains the MMPB method even if alternative methods and, in particular, deconjugation at basic pH, showed results encouraging the continuation of the methodological development on different matrices and on naturally-contaminated samples.
Collapse
Affiliation(s)
- Pierre Bouteiller
- Université de Reims Champagne-Ardenne, UMR-I 02 INERIS-URCA-ULH SEBIO, Unité Stress Environnementaux et BIOsurveillance des Milieux Aquatiques (SEBIO), BP 1039, CEDEX 2, F-51687 Reims, France
- Laboratory for Food Safety, ANSES, F-94701 Maisons-Alfort, France
| | - Emilie Lance
- Université de Reims Champagne-Ardenne, UMR-I 02 INERIS-URCA-ULH SEBIO, Unité Stress Environnementaux et BIOsurveillance des Milieux Aquatiques (SEBIO), BP 1039, CEDEX 2, F-51687 Reims, France
- UMR MNHN/CNRS MCAM, Muséum National d’Histoire Naturelle, F-75005 Paris, France
- Correspondence:
| | - Thierry Guérin
- Strategy and Programs Department, ANSES, F-94701 Maisons-Alfort, France
| | - Ronel Biré
- Laboratory for Food Safety, ANSES, F-94701 Maisons-Alfort, France
| |
Collapse
|
4
|
Jagerdeo E, Auger S. Rapid screening procedures for a variety of complex forensic samples using laser diode thermal desorption (LDTD) coupled to different mass spectrometers. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9244. [PMID: 34984743 DOI: 10.1002/rcm.9244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Revised: 12/06/2021] [Accepted: 12/15/2021] [Indexed: 06/14/2023]
Abstract
RATIONALE The applications shared in this paper demonstrate the wide variety of samples that can be analyzed when Laser Diode Thermal Desorption (LDTD) is interfaced with a high-resolution mass spectrometer and show the speed at which high quality data can be generated from complex matrices. METHODS Samples are solvent extracted and spotted in a 96-well plate. In the case of biological fluids, hydrolysis followed by solid-phase extraction is required. The solvent in the 96-well plate is evaporated followed by mass spectrometric (MS) analysis with atmospheric pressure chemical ionization. Where applicable, the instrument is operated in data-dependent mode, with a full-scan mass spectrum followed by MS/MS spectra of the top 10 ions with a total runtime of 0.4 min. RESULTS Four applications (MAAQ and Tear Gas, twelve rodenticides, seven explosives, and 40 drugs of abuse) are reported in this paper. MAAQ, tear gas, and rodenticides were identified by full-scan, followed by MS/MS experiments at levels of 125 μg/L, 125 μg/L, and 500 μg/L, respectively. Explosives were all identified at 102 μg/L by full-scan experiments. The drugs of abuse were identified by multiple reaction monitoring (MRM) experiments at defined cutoff levels from 2 to 1000 μg/L. CONCLUSIONS Interfacing LDTD with a mass spectrometer allows for rapid screening of a wide range of samples, with either minimal or complex sample preparation. Using a high-resolution mass spectrometer with the combination to perform full-scan and MS/MS experiments adds a high level of specificity.
Collapse
Affiliation(s)
- Eshwar Jagerdeo
- Federal Bureau of Investigation Laboratory, Quantico, VA, USA
| | | |
Collapse
|
5
|
Foss AJ, Miles CO, Wilkins AL, Rise F, Trovik KW, Cieslik K, Aubel MT. Analysis of total microcystins and nodularins by oxidative cleavage of their ADMAdda, DMAdda, and Adda moieties. Anal Chim Acta X 2020; 6:100060. [PMID: 33392496 PMCID: PMC7772689 DOI: 10.1016/j.acax.2020.100060] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Revised: 08/27/2020] [Accepted: 08/29/2020] [Indexed: 11/17/2022] Open
Abstract
Microcystins (MCs) and nodularins (NODs) exhibit high structural variability, including modifications of the Adda (3S-amino-9S-methoxy-2S,6,8S-trimethyl-10-phenyldeca-4E,6E-dienoic acid) moiety. Variations include 9-O-desmethylAdda (DMAdda) and 9-O-acetylDMAdda (ADMAdda) which, unless targeted, may go undetected. Therefore, reference standards were prepared of [ADMAdda5]MCs and [DMAdda5]MCs, which were analyzed using multiple approaches. The cross-reactivities of the [DMAdda5]- and [ADMAdda5]MC standards were similar to that of MC-LR when analyzed with a protein phosphatase 2A (PP2A) inhibition assay, but were <0.25% when analyzed with an Adda enzyme-linked immunosorbent assay (ELISA). Oxidative cleavage experiments identified compounds that could be used in the analysis of total MCs/NODs in a similar fashion to the 2R-methyl-3S-methoxy-4-phenylbutanoic acid (MMPB) technique. Products from oxidative cleavage of both the 4,5- and 6,7-ene of Adda, DMAdda and ADMAdda were observed, and three oxidation products, one from each Adda variant, were chosen for analysis and applied to three field samples and a Nostoc culture. Results from the oxidative cleavage method for total Adda, DMAdda, and ADMAdda were similar to those from the Adda-ELISA, PP2A inhibition, and LC-MS/MS analyses, except for the Nostoc culture where the Adda-ELISA greatly underestimated microcystin levels. This oxidative cleavage method can be used for routine analysis of field samples and to assess the presence of the rarely reported, but toxic, DMAdda/ADMAdda-containing MCs and NODs.
Collapse
Key Words
- ADMAdda
- ADMAdda, 3S-amino-9S-acetyloxy-2S,6,8S-trimethyl-10-phenyldeca-4E,6E-dienoic acid
- Adda
- Adda, 3S-amino-9S-methoxy-2S,6,8S-trimethyl-10-phenyldeca-4E,6E-dienoic acid
- DMAdda
- DMAdda, 3S-amino-9S-hydroxy-2S,6,8S-trimethyl-10-phenyldeca-4E,6E-dienoic acid
- MAPB, 2R-methyl-3S-acetyloxy-4-phenylbutanoic acid
- MHPB, 2R-methyl-3S-hydroxy-4-phenylbutanoic acid
- MMPB
- MMPB, 2R-methyl-3S-methoxy-4-phenylbutanoic acid
- MOMAPH, 2-methyl-3-oxo-4R-methyl-5S-acetyloxy-6-phenylhexanoic acid
- MOMHPH, 2-methyl-3-oxo-4R-methyl-5S-hydroxy-6-phenylhexanoic acid
- MOMMPH, 2-methyl-3-oxo-4R-methyl-5S-methoxy-6-phenylhexanoic acid
- Microcystin
- Microcystin, MC
- NOD, Nodularin
- Nodularin
Collapse
Affiliation(s)
- Amanda J. Foss
- GreenWater Laboratories/CyanoLab, 205 Zeagler Drive, Palatka, FL, 32177, USA
| | - Christopher O. Miles
- Measurement Science and Standards, National Research Council, 1411 Oxford Street, Halifax, NS, B3H 3Z1, Canada
- Norwegian Veterinary Institute, P. O. Box 750, Sentrum, N-0106, Oslo, Norway
| | - Alistair L. Wilkins
- Norwegian Veterinary Institute, P. O. Box 750, Sentrum, N-0106, Oslo, Norway
- Chemistry Department, University of Waikato, Private Bag 3105, 3240, Hamilton, New Zealand
- Department of Chemistry, University of Oslo, P.O. Box 1033, N-0315, Oslo, Norway
| | - Frode Rise
- Department of Chemistry, University of Oslo, P.O. Box 1033, N-0315, Oslo, Norway
| | - Kristian W. Trovik
- Department of Chemistry, University of Oslo, P.O. Box 1033, N-0315, Oslo, Norway
| | - Kamil Cieslik
- GreenWater Laboratories/CyanoLab, 205 Zeagler Drive, Palatka, FL, 32177, USA
| | - Mark T. Aubel
- GreenWater Laboratories/CyanoLab, 205 Zeagler Drive, Palatka, FL, 32177, USA
| |
Collapse
|
6
|
Anaraki MT, Shahmohamadloo RS, Sibley PK, MacPherson K, Bhavsar SP, Simpson AJ, Ortiz Almirall X. Optimization of an MMPB Lemieux Oxidation method for the quantitative analysis of microcystins in fish tissue by LC-QTOF MS. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 737:140209. [PMID: 32783840 DOI: 10.1016/j.scitotenv.2020.140209] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 06/11/2020] [Accepted: 06/12/2020] [Indexed: 06/11/2023]
Abstract
Microcystins are toxic heptapeptides produced by cyanobacteria in marine and freshwater environments. In biological samples such as fish, microcystins can be found in the free form or covalently bound to protein phosphatases type I and II. Total microcystins in fish have been quantified in the past using the Lemieux Oxidation approach, where all toxins are oxidated to a common fragment (2-methyl-3-methoxy-4-phenylbutyric acid, MMPB) regardless of their initial amino acid configuration or form (free or protein bound). These studies have been carried out using different experimental conditions and employed different quantification strategies. The present study has further investigated the oxidation step using a systematic approach, to identify the most important factors leading to a higher, more robust MMPB generation yield from fish tissue in order to reduce the method detection limit. Field samples were quantified using an in-situ generated MMPB matrix matched calibration curve by isotope dilution with d3-MMPB via liquid chromatography coupled to time-of-flight mass spectrometry (LC-QTOF MS). This approach improves method's accuracy by taking into account of potential matrix effects that could affect the derivatization, sample prepation and instrumental analysis steps. The validated method showed 16.7% precision (RSD) and +6.7% accuracy (bias), with calculated method detection limits of 7.28 ng g-1 Performance of the method was assessed with the analysis of laboratory exposed Rainbow Trout (Oncorhynchus mykiss) to cyanobacteria as a positive control, where no microcystins were detected in the pre-exposure fish liver and fillet, low levels in the exposed fillet (65.0 ng g-1) and higher levels in the exposed liver (696 ng g-1). Finally, the method was employed for the analysis of 26 fillets (muscle) and livers of Walleye (Sander vitreus) and Yellow Perch (Perca flavescens) from Lake Erie, showing very low concentrations of microcystins in the fillet and higher concentrations in liver, up to 3720 ng g-1.
Collapse
Affiliation(s)
- Maryam Tabatabaei Anaraki
- Department of Physical and Environment Sciences, University of Toronto Scarborough, Toronto, ON, Canada
| | | | - Paul K Sibley
- School of Environmental Sciences, University of Guelph, Guelph, ON, Canada
| | - Karen MacPherson
- Ontario Ministry of the Environment, Conservation, and Parks, Toronto, ON, Canada
| | - Satyendra P Bhavsar
- Department of Physical and Environment Sciences, University of Toronto Scarborough, Toronto, ON, Canada; Ontario Ministry of the Environment, Conservation, and Parks, Toronto, ON, Canada
| | - André J Simpson
- Department of Physical and Environment Sciences, University of Toronto Scarborough, Toronto, ON, Canada
| | - Xavier Ortiz Almirall
- Ontario Ministry of the Environment, Conservation, and Parks, Toronto, ON, Canada; School of Environmental Sciences, Queen's University, Kingston, ON, Canada.
| |
Collapse
|
7
|
Ultrafast laser diode thermal desorption method for analysis of representative pharmaceuticals in soil leachate samples. Talanta 2020; 208:120382. [PMID: 31816693 DOI: 10.1016/j.talanta.2019.120382] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2019] [Revised: 09/18/2019] [Accepted: 09/19/2019] [Indexed: 02/06/2023]
Abstract
We developed and evaluated a novel analytical method combining ambient ionization technique - laser diode thermal desorption with chemical ionization (LDTD-APCI) and tandem mass spectrometry detection. The LDTD/APCI-MS/MS method was developed for determination of representative pharmaceuticals from different classes (carbamazepine, sulfamethoxazole, irbesartan, fexofenadine) in leachate samples from soil sorption experimentation. We then optimized laser pattern, laser energy and spiked sample volume, which are crucial parameters for this LDTD/APCI-MS/MS method. We further identified utility of a chelating agent (Na2-EDTA) to obtain the highest achievable and reproducible signal of target analytes. Achieved method performance parameters (LODs, LOQs, trueness and precision) were comparable with those obtained from LC-MS/MS. However, application of this novel LDTD/APCI-MS/MS method reduced analysis time by two orders of magnitude (to 12 s), compared to more conventional LC-MS/MS approaches, without use of organic solvents. We expect this novel method will reduce costs and increase throughput for future analyses of pharmaceuticals in the environment while advancing a timely principle of green chemistry.
Collapse
|
8
|
Racine M, Saleem A, Pick FR. Metabolome Variation between Strains of Microcystis aeruginosa by Untargeted Mass Spectrometry. Toxins (Basel) 2019; 11:E723. [PMID: 31835794 PMCID: PMC6950387 DOI: 10.3390/toxins11120723] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Revised: 12/01/2019] [Accepted: 12/04/2019] [Indexed: 12/19/2022] Open
Abstract
Cyanobacteria are notorious for their potential to produce hepatotoxic microcystins (MCs), but other bioactive compounds synthesized in the cells could be as toxic, and thus present interest for characterization. Ultra performance liquid chromatography and high-resolution accurate mass spectrometry (UPLC-QTOF-MS/MS) combined with untargeted analysis was used to compare the metabolomes of five different strains of the common bloom-forming cyanobacterium, Microcystis aeruginosa. Even in microcystin-producing strains, other classes of oligopeptides including cyanopeptolins, aeruginosins, and aerucyclamides, were often the more dominant compounds. The distinct and large variation between strains of the same widespread species highlights the need to characterize the metabolome of a larger number of cyanobacteria, especially as several metabolites other than microcystins can affect ecological and human health.
Collapse
Affiliation(s)
- Marianne Racine
- Department of Biology, University of Ottawa, Ottawa, ON K1N 6N5, Canada; (A.S.); (F.R.P.)
- Current address: Environment and Climate Change Canada, Canada Centre for Inland Waters, Burlington, ON L7S 1A1, Canada
| | - Ammar Saleem
- Department of Biology, University of Ottawa, Ottawa, ON K1N 6N5, Canada; (A.S.); (F.R.P.)
| | - Frances R. Pick
- Department of Biology, University of Ottawa, Ottawa, ON K1N 6N5, Canada; (A.S.); (F.R.P.)
| |
Collapse
|
9
|
Gravel A, Guérette C, Fortin D, Auger S, Picard P, Segura PA. Further studies on the signal enhancement effect in laser diode thermal desorption-triple quadrupole mass spectrometry using microwell surface coatings. JOURNAL OF MASS SPECTROMETRY : JMS 2019; 54:948-956. [PMID: 31652386 DOI: 10.1002/jms.4455] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 09/06/2019] [Accepted: 10/04/2019] [Indexed: 06/10/2023]
Abstract
The laser diode thermal desorption (LDTD) ionization source allows ultrafast and sensitive analysis of small molecules by mass spectrometry. Signal enhancement in LDTD has been observed when coating the surface of sample microwells with a solution of ethylenediaminetetraacetic acid (EDTA) or nitrilotriacetic acid. Here we present a quantitative analysis of signal enhancement using solutions of diverse commercial proteins (lysozyme, immunoglobulin G, albumin, and fibrinogen) as coatings. Results showed that compounds with polar chemical functions such as carboxylic acid, sulfonyl, and nitro had signal enhancement factors, in most cases higher than 10, when using any of the tested proteins as coating agent. Analysis of variance revealed that immunoglobulin G and fibrinogen gave the best results. However, the signal enhancement factors obtained with these proteins were not superior to those observed with EDTA. To explain the signal enhancement effect of proteins, analysis by scanning electron microscopy of dried samples on the microwell sample plates was carried out. Images showed that salicylic acid, one of the compounds with the highest observed signal enhancement, formed a thick layer when applied directly on the uncoated surface, but it formed small crystals (<1 μm) in the presence of protein or EDTA coatings. Further crystallographic studies using powder X-ray diffraction showed that the crystalline form of salicylic acid is modified in the presence of EDTA. Salicylic acid when mixed with EDTA had a higher percentage of amorphous phase (38.1%) than without EDTA (23.1%). These results appear to confirm that the diminution of crystal size of analytes and the increase of amorphous phase are implicated in signal enhancement effect observed in LDTD using microwell surface coatings. To design better coatings and completely elucidate the signal enhancement effect in LDTD, more studies are necessary to understand the effects of coatings on the ionization of analytes.
Collapse
Affiliation(s)
- Alexia Gravel
- Department of Chemistry, Université de Sherbrooke, Sherbrooke, Canada
| | | | - Daniel Fortin
- Department of Chemistry, Université de Sherbrooke, Sherbrooke, Canada
| | | | | | - Pedro A Segura
- Department of Chemistry, Université de Sherbrooke, Sherbrooke, Canada
| |
Collapse
|
10
|
Shen Q, Feng J, Wang J, Li S, Wang Y, Ma J, Wang H. Laser irradiation desorption of microcystins from protein complex in fish tissue and liquid chromatography-tandem mass spectrometry analysis. Electrophoresis 2019; 40:1805-1811. [PMID: 31106441 DOI: 10.1002/elps.201900141] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 05/15/2019] [Accepted: 05/16/2019] [Indexed: 11/07/2022]
Abstract
Microcystins are a group of cyanotoxins which interact with the C-terminal region of PP1 and PP2A proteins, so denaturation and inactivation are necessary for breaking covalent binding to release microcystins. In this study, a novel extraction method was developed by laser irradiation desorption of microcystins from fish protein. The sample was mixed with aqueous methanol and irradiated by a 450 nm laser, with an optimized value of laser power density at 8 W and exposure time at 5 min. ThenLC-MS/MS was applied for the determination of microcystins in fish extracts. The ionization behaviors of microcystins were investigated firstly, and doubly charged microcystins were selected as precursor ions in multiple reaction monitoring scan for quantification. This proposed quantitative method was well validated in terms of selectivity, linearity, sensitivity, accuracy, recovery, and stability. The successful application of this LC-MS/MS method showed its ability for the analysis of microcystins in low concentration, and it would be of significant interest for environmental and food safety applications to ensure the safety of fish and related products.
Collapse
Affiliation(s)
- Qing Shen
- Zhejiang Province Key Laboratory of Anesthesiology, Department of Anesthesiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, P. R. China.,Zhejiang Province Joint Key Laboratory of Aquatic Products Processing, Institute of Seafood, Zhejiang Gongshang University, Hangzhou, P. R. China
| | - Junli Feng
- Zhejiang Province Joint Key Laboratory of Aquatic Products Processing, Institute of Seafood, Zhejiang Gongshang University, Hangzhou, P. R. China
| | - Jie Wang
- Zhejiang Province Joint Key Laboratory of Aquatic Products Processing, Institute of Seafood, Zhejiang Gongshang University, Hangzhou, P. R. China
| | - Shiyan Li
- Aquatic Products Quality Inspection Center of Zhejiang Province, Hangzhou, P. R. China
| | - Yang Wang
- Aquatic Products Quality Inspection Center of Zhejiang Province, Hangzhou, P. R. China
| | - Jianfeng Ma
- Zhejiang Province Key Laboratory of Anesthesiology, Department of Anesthesiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, P. R. China
| | - Haixing Wang
- Zhejiang Province Key Laboratory of Anesthesiology, Department of Anesthesiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, P. R. China
| |
Collapse
|
11
|
Picardo M, Filatova D, Nuñez O, Farré M. Recent advances in the detection of natural toxins in freshwater environments. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.12.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
12
|
Dion-Fortier A, Gravel A, Guérette C, Chevillot F, Blais S, Auger S, Picard P, Segura PA. Signal enhancement in laser diode thermal desorption-triple quadrupole mass spectrometry analysis using microwell surface coatings. JOURNAL OF MASS SPECTROMETRY : JMS 2019; 54:167-177. [PMID: 30600862 DOI: 10.1002/jms.4328] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 12/20/2018] [Accepted: 12/20/2018] [Indexed: 06/09/2023]
Abstract
Laser-diode thermal desorption (LDTD) is an ionization source usually coupled to triple quadrupole mass spectrometry (QqQMS) and specifically designed for laboratories requiring high-throughput analysis. It has been observed that surface coatings on LDTD microwell plates can improve the sensitivity of the analysis of small polar molecules. The objective of the present study is to understand and quantify the effect of microwell surface coatings on signal intensity of small organic molecules of clinical, environmental, and forensic interest. Experiments showed that the peak areas of diclofenac, chloramphenicol, salicylic acid, and 11-nor-9-carboxy-Δ9 -tetrahydrocannabinol obtained by LDTD-QqQMS increased by up to 3 orders of magnitude when using microwells coated with ethylenediaminetetraacetic acid (EDTA). Tests with different chelating agents and polytetrafluoroethylene as microwell surface coatings showed that nitrilotriacetic acid gave significantly higher peak areas for five out of the nine compounds that showed signal enhancement using chelating agents as coatings. Scanning electron microscopy studies of EDTA-coated and uncoated microwells showed that analytes deposited in the former formed more uniform and thinner films than in the latter. The enhancement effect of surface coatings in LDTD-QqQMS was explained mainly by the formation of homogenous and thinner layers of nanocrystals of analytes that are easier to desorb thermally than the layers formed when the analytes dry in direct contact with the bare stainless-steel surface. Chemisorption of some analytes to the stainless-steel surface of the microwell plate appeared to be a minor factor. Surface coatings widen the number of compounds analyzable by LDTD-QqQMS and can also improve sensitivity and limits of detection.
Collapse
Affiliation(s)
- Annick Dion-Fortier
- Department of Chemistry, Université de Sherbrooke, Sherbrooke, QC, J1K 2R1, Canada
| | - Alexia Gravel
- Department of Chemistry, Université de Sherbrooke, Sherbrooke, QC, J1K 2R1, Canada
| | - Cassandra Guérette
- Department of Chemistry, Université de Sherbrooke, Sherbrooke, QC, J1K 2R1, Canada
| | - Fanny Chevillot
- Department of Chemistry, Université de Sherbrooke, Sherbrooke, QC, J1K 2R1, Canada
| | - Sonia Blais
- Centre de caractérisation des matériaux, Université de Sherbrooke, Sherbrooke, QC, J1K 2R1, Canada
| | - Serge Auger
- Phytronix Technologies, Québec, QC, G1P 2J7, Canada
| | | | - Pedro A Segura
- Department of Chemistry, Université de Sherbrooke, Sherbrooke, QC, J1K 2R1, Canada
| |
Collapse
|
13
|
Li S, Cui Y, Wang Y, Dai Z, Shen Q. A shotgun method for high throughput screening microcystins in Margarya melanioides on a triple quadrupole tandem mass spectrometry. Food Chem 2018; 269:89-95. [DOI: 10.1016/j.foodchem.2018.07.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Revised: 05/27/2018] [Accepted: 07/01/2018] [Indexed: 11/17/2022]
|
14
|
Ahn S, Magaña AA, Bozarth C, Shepardson J, Morré J, Dreher T, Maier CS. Integrated identification and quantification of cyanobacterial toxins from Pacific Northwest freshwaters by Liquid Chromatography and High-resolution Mass Spectrometry. J MEX CHEM SOC 2018; 62:10.29356/jmcs.v62i2.386. [PMID: 30214641 PMCID: PMC6133267 DOI: 10.29356/jmcs.v62i2.386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The occurrence of harmful algal blooms in nutrient-rich freshwater bodies has increased world-wide, including in the Pacific Northwest. Some cyanobacterial genera have the potential to produce secondary metabolites that are highly toxic to humans, livestock and wildlife. Reliable methods for the detection of cyanobacterial toxins with high specificity and low limits of detection are in high demand. Here we test a relatively new hybrid high resolution accurate mass quadrupole time-of-flight mass spectrometry platform (TripleTOF) for the analysis of cyanobacterial toxins in freshwater samples. We developed a new method that allows the quantitative analysis of four commonly observed microcystin congeners (LR, LA, YR, and RR) and anatoxin-a in a 6-min LC run without solid-phase enrichment. Limits of detection for the microcystin congeners (LR, LA, YR, and RR) and anatoxin-a were <5 ng/L (200-fold lower than the guideline value of 1 μg/L as maximum allowable concentration of MC-LR in drinking water). The method was applied for screening freshwaters in the Pacific Northwest during the bloom and post-bloom periods. The use of high resolution mass spectrometry and concomitant high sensitivity detection of specific fragment ions with high mass accuracy provides an integrated approach for the simultaneous identification and quantification of cyanobacterial toxins. The method is sensitive enough for detecting the toxins in single Microcystis colonies.
Collapse
Affiliation(s)
- Soyoun Ahn
- Department of Chemistry, Oregon State University, Corvallis, Oregon 97331, USA
| | | | - Connie Bozarth
- Department of Microbiology, Oregon State University, Corvallis, Oregon 97331, USA
| | - Jonathan Shepardson
- Department of Microbiology, Oregon State University, Corvallis, Oregon 97331, USA
| | - Jeffery Morré
- Department of Chemistry, Oregon State University, Corvallis, Oregon 97331, USA
| | - Theo Dreher
- Department of Microbiology, Oregon State University, Corvallis, Oregon 97331, USA
- Center for Genome Research and Biocomputing, Oregon State University, Corvallis, Oregon 97331, USA
| | - Claudia S. Maier
- Department of Chemistry, Oregon State University, Corvallis, Oregon 97331, USA
| |
Collapse
|
15
|
Rosenblum L, Zaffiro A, Adams WA, Wendelken SC. Effect of chlorination by-products on the quantitation of microcystins in finished drinking water. Toxicon 2017; 138:138-144. [PMID: 28860036 DOI: 10.1016/j.toxicon.2017.08.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Revised: 08/24/2017] [Accepted: 08/26/2017] [Indexed: 11/18/2022]
Abstract
Microcystins are toxic peptides that can be produced by cyanobacteria in harmful algal blooms (HABs). Various analytical techniques have been developed to quantify microcystins in drinking water, including liquid chromatography tandem mass spectrometry (LC/MS/MS), enzyme linked immunosorbent assay (ELISA), and oxidative cleavage to produce 2-methyl-3-methoxy-4-phenylbutyric acid (MMPB) with detection by LC/MS/MS, the "MMPB method". Both the ELISA and MMPB methods quantify microcystins by detecting a portion of the molecule common to most microcystins. However, there is little research evaluating the effect of microcystin chlorination by-products potentially produced during drinking water treatment on analytical results. To evaluate this potential, chlorinated drinking water samples were fortified with various microcystin congeners in bench-scale studies. The samples were allowed to react, followed by a comparison of microcystin concentrations measured using the three methods. The congener-specific LC/MS/MS method selectively quantified microcystins and was not affected by the presence of chlorination by-products. The ELISA results were similar to those obtained by LC/MS/MS for most microcystin congeners, but results deviated for a particular microcystin containing a variable amino acid susceptible to oxidation. The concentrations measured by the MMPB method were at least five-fold higher than the concentrations of microcystin measured by the other methods and demonstrate that detection of MMPB does not necessarily correlate to intact microcystin toxins in finished drinking water.
Collapse
Affiliation(s)
- Laura Rosenblum
- CB&I Federal Services, 26 W. Martin Luther King, Cincinnati, OH 45268, USA
| | - Alan Zaffiro
- CB&I Federal Services, 26 W. Martin Luther King, Cincinnati, OH 45268, USA
| | - William A Adams
- US EPA Office of Water, 26 W. Martin Luther King, Cincinnati, OH 45268, USA.
| | - Steven C Wendelken
- US EPA Office of Water, 26 W. Martin Luther King, Cincinnati, OH 45268, USA
| |
Collapse
|
16
|
Munoz G, Vo Duy S, Roy-Lachapelle A, Husk B, Sauvé S. Analysis of individual and total microcystins in surface water by on-line preconcentration and desalting coupled to liquid chromatography tandem mass spectrometry. J Chromatogr A 2017; 1516:9-20. [PMID: 28822574 DOI: 10.1016/j.chroma.2017.07.096] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2017] [Revised: 07/28/2017] [Accepted: 07/31/2017] [Indexed: 12/18/2022]
Abstract
A fast and high-throughput method is proposed for the determination of total microcystins (ΣMC) in environmental surface waters. After a 1-h Lemieux-von Rudloff oxidation step to yield the 2-methyl-3-methoxy-4-phenylbutyric acid (MMPB) moiety, samples were quenched, filtered, and directly analyzed. This was achieved via solid phase extraction (SPE) coupled on-line to ultra-high performance liquid chromatography electrospray ionization triple stage quadrupole mass spectrometry. The choice of on-line SPE settings was conducted using experimental designs. Given the matrix complexity of oxidation extracts, the on-line desalting step was found to be a critical parameter to ensure suitable method robustness. The on-line sample loading volume was 5mL, and the wash volume applied for on-line desalting was 3mL. Instrumental analysis was performed in just 8min. The method limit of quantification was 0.5ngL-1 ΣMC (i.e. 2000 times lower than the current World Health Organization - WHO drinking water guideline). Excellent determination coefficients were observed for matrix-free and matrix-based calibration curves alike, and the linearity range tested spanned∼4 orders of magnitude. Accuracy and intermediate precision did not depend on the spike level and proved satisfactory (in the range of 93-110% and 3-6%, respectively). A thorough assessment of instrumental matrix effects was conducted by comparing standard additions curves in several lake and river oxidation extracts with the matrix-free reference. Regardless of the internal standard used (4-PB or D3-MMPB), instrumental matrix effects were efficiently compensated. The matrix effect that may occur at the earlier sample preparation stage was evaluated separately. While the oxidation step was generally not complete (yield ∼65%), the conversion rates of MCs into MMPB remained within a consistent range of values regardless of matrix type. No significant back-pressure was observed upon consecutive injections of oxidation-based samples, while the instrumental sensitivity remained unaffected. The herein described method could therefore be eligible for future large-scale monitoring surveys. The method was applied to a selection of surface water samples (n=30) collected across the province of Québec, Canada, and the results were compared to those achieved by an individual variant analysis of 8 MC congeners and a commercial ELISA kit.
Collapse
Affiliation(s)
- Gabriel Munoz
- Department of Chemistry, Université de Montréal, 2900 Edouard Montpetit, H3C 3J7, Montréal, QC, Canada
| | - Sung Vo Duy
- Department of Chemistry, Université de Montréal, 2900 Edouard Montpetit, H3C 3J7, Montréal, QC, Canada
| | - Audrey Roy-Lachapelle
- Department of Chemistry, Université de Montréal, 2900 Edouard Montpetit, H3C 3J7, Montréal, QC, Canada; Environment and Climate Change Canada, 105 rue McGill, H2Y 2E7, Montréal, QC, Canada
| | - Barry Husk
- BlueLeaf Inc., 310 Chapleau Street, J2B 5E9, Drummondville, QC, Canada
| | - Sébastien Sauvé
- Department of Chemistry, Université de Montréal, 2900 Edouard Montpetit, H3C 3J7, Montréal, QC, Canada.
| |
Collapse
|
17
|
Gaget V, Lau M, Sendall B, Froscio S, Humpage AR. Cyanotoxins: Which detection technique for an optimum risk assessment? WATER RESEARCH 2017; 118:227-238. [PMID: 28433693 DOI: 10.1016/j.watres.2017.04.025] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2017] [Revised: 04/04/2017] [Accepted: 04/08/2017] [Indexed: 05/28/2023]
Abstract
The presence of toxigenic cyanobacteria (blue-green algae) in drinking water reservoirs poses a risk to human and animal health worldwide. Guidelines and health alert levels have been issued in the Australian Drinking Water Guidelines for three major toxins, which are therefore the subject of routine monitoring: microcystin, cylindrospermopsin and saxitoxin. While it is agreed that these toxic compounds should be monitored closely, the routine surveillance of these bioactive chemicals can be done in various ways and deciding which technique to use can therefore be challenging. This study compared several assays available for the detection of these toxins and their producers in environmental samples: microscopy (for identification and enumeration of cyanobacteria), ELISA (Enzyme-Linked ImmunoSorbant Assay), PPIA (Protein phosphatase inhibition assay), PSI (Protein synthesis inhibition), chemical analysis and PCR (Polymerase Chain Reaction). Results showed that there was generally a good correlation between the presence of potentially toxigenic cyanobacteria and the detection of the toxin by ELISA. Nevertheless data suggest that cell numbers and toxin concentrations measured in bioassays do not necessarily correlate and that enumeration of potentially toxic cyanobacteria by microscopy, while commonly used for monitoring and risk assessment, is not the best indicator of real toxin exposure. The concentrations of saxitoxins quantified by ELISA were significantly different than those measured by LC-MS, while results were comparable in both assays for microcystin and cylindrospermopsin. The evaluation of these analytical methods led to the conclusion that there is no "gold standard" technique for the detection of the aforementioned cyanotoxins but that the choice of detection assay depends on cost, practicality, reliability and comparability of results and essentially on the question to be answered, notably on toxin exposure potential.
Collapse
Affiliation(s)
- Virginie Gaget
- South Australia Water Corporation, Australian Water Quality Centre, 250 Victoria Square, Adelaide, SA 5000, Australia.
| | - Melody Lau
- South Australia Water Corporation, Australian Water Quality Centre, 250 Victoria Square, Adelaide, SA 5000, Australia
| | - Barbara Sendall
- Queensland Health Forensic and Scientific Services, 39 Kessels Road, Coopers Plains, QLD 4108, Australia
| | - Suzanne Froscio
- South Australia Water Corporation, Australian Water Quality Centre, 250 Victoria Square, Adelaide, SA 5000, Australia
| | - Andrew R Humpage
- South Australia Water Corporation, Australian Water Quality Centre, 250 Victoria Square, Adelaide, SA 5000, Australia
| |
Collapse
|
18
|
Roy-Lachapelle A, Solliec M, Bouchard MF, Sauvé S. Detection of Cyanotoxins in Algae Dietary Supplements. Toxins (Basel) 2017; 9:E76. [PMID: 28245621 PMCID: PMC5371831 DOI: 10.3390/toxins9030076] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Revised: 02/17/2017] [Accepted: 02/21/2017] [Indexed: 11/16/2022] Open
Abstract
Algae dietary supplements are marketed worldwide as natural health products. Although their proprieties have been claimed as beneficial to improve overall health, there have been several previous reports of contamination by cyanotoxins. These products generally contain non-toxic cyanobacteria, but the methods of cultivation in natural waters without appropriate quality controls allow contamination by toxin producer species present in the natural environment. In this study, we investigated the presence of total microcystins, seven individual microcystins (RR, YR, LR, LA, LY, LW, LF), anatoxin-a, dihydroanatoxin-a, epoxyanatoxin-a, cylindrospermopsin, saxitoxin, and β-methylamino-l-alanine in 18 different commercially available products containing Spirulina or Aphanizomenon flos-aquae. Total microcystins analysis was accomplished using a Lemieux oxidation and a chemical derivatization using dansyl chloride was needed for the simultaneous analysis of cylindrospermopsin, saxitoxin, and β-methylamino-l-alanine. Moreover, the use of laser diode thermal desorption (LDTD) and ultra-high performance liquid chromatography (UHPLC) both coupled to high resolution mass spectrometry (HRMS) enabled high performance detection and quantitation. Out of the 18 products analyzed, 8 contained some cyanotoxins at levels exceeding the tolerable daily intake values. The presence of cyanotoxins in these algal dietary supplements reinforces the need for a better quality control as well as consumer's awareness on the potential risks associated with the consumption of these supplements.
Collapse
Affiliation(s)
| | - Morgan Solliec
- Department of Chemistry, Université de Montréal, Montréal, QC H3T 1J4, Canada.
| | - Maryse F Bouchard
- Department of Environmental and Occupational Health, Université de Montréal, Montréal, QC H3T 1A8, Canada.
| | - Sébastien Sauvé
- Department of Chemistry, Université de Montréal, Montréal, QC H3T 1J4, Canada.
| |
Collapse
|
19
|
Mashile GP, Nomngongo PN. Recent Application of Solid Phase Based Techniques for Extraction and Preconcentration of Cyanotoxins in Environmental Matrices. Crit Rev Anal Chem 2016; 47:119-126. [DOI: 10.1080/10408347.2016.1225255] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
20
|
Balest L, Murgolo S, Sciancalepore L, Montemurro P, Abis PP, Pastore C, Mascolo G. Ultra-trace levels analysis of microcystins and nodularin in surface water by on-line solid-phase extraction with high-performance liquid chromatography tandem mass spectrometry. Anal Bioanal Chem 2016; 408:4063-71. [DOI: 10.1007/s00216-016-9495-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2016] [Revised: 03/07/2016] [Accepted: 03/16/2016] [Indexed: 10/22/2022]
|
21
|
Zhang LL, Yu RP, Wang LP, Wu SF, Song QJ. Transformation of microcystins to 2-methyl-3-methoxy-4-phenylbutyric acid by room temperature ozone oxidation for rapid quantification of total microcystins. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2016; 18:493-499. [PMID: 26975781 DOI: 10.1039/c5em00588d] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Microcystins (MCs) are cyanobacterial hepatotoxins capable of accumulation into animal tissues. To determine the total microcystins in water, a novel analytical method, including ozonolysis, methylation of 2-methyl-3-methoxy-4-phenylbutyric acid (MMPB) with methylchloroformate (MCF) and gas chromatography mass spectrometry (GC-MS) detection was developed. The results show that MCs can be oxidized by ozone to produce MMPB at ambient temperature, proving ozonation is an effective, rapid and green method for the transformation of MCs to MMPB without secondary pollution. The oxidation conditions as well as the esterification process were optimized and, subsequently applied to analysis of environmental samples. The method shows wide linear range and high sensitivity with a detection limit of 0.34 μg L(-1). The established method was successfully applied to the analysis of microcystins in water samples.
Collapse
Affiliation(s)
- L L Zhang
- Key Laboratory of Food Colloids and Biotechnology, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi 214122, China.
| | | | | | | | | |
Collapse
|
22
|
Foss AJ, Aubel MT. Using the MMPB technique to confirm microcystin concentrations in water measured by ELISA and HPLC (UV, MS, MS/MS). Toxicon 2015. [DOI: 10.1016/j.toxicon.2015.07.332] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
23
|
Munoz G, Vo Duy S, Budzinski H, Labadie P, Liu J, Sauvé S. Quantitative analysis of poly- and perfluoroalkyl compounds in water matrices using high resolution mass spectrometry: Optimization for a laser diode thermal desorption method. Anal Chim Acta 2015; 881:98-106. [DOI: 10.1016/j.aca.2015.04.015] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2014] [Revised: 03/11/2015] [Accepted: 04/03/2015] [Indexed: 11/26/2022]
|
24
|
Roy-Lachapelle A, Solliec M, Sinotte M, Deblois C, Sauvé S. High resolution/accurate mass (HRMS) detection of anatoxin-a in lake water using LDTD-APCI coupled to a Q-Exactive mass spectrometer. Talanta 2014; 132:836-44. [PMID: 25476385 DOI: 10.1016/j.talanta.2014.10.021] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2014] [Revised: 10/06/2014] [Accepted: 10/10/2014] [Indexed: 10/24/2022]
Abstract
A new innovative analytical method combining ultra-fast analysis time with high resolution/accurate mass detection was developed to eliminate the misidentification of anatoxin-a (ANA-a), a cyanobacterial toxin, from the natural amino acid phenylalanine (PHE). This was achieved by using the laser diode thermal desorption-atmospheric pressure chemical ionization (LDTD-APCI) coupled to the Q-Exactive, a high resolution/accurate mass spectrometer (HRMS). This novel combination, the LDTD-APCI-HRMS, allowed for an ultra-fast analysis time (<15 s/sample). A comparison of two different acquisition modes (full scan and targeted ion fragmentation) was made to determine the most rigorous analytical method using the LDTD-APCI interface. Method development focused toward selectivity and sensitivity improvement to reduce the possibility of false positives and to lower detection limits. The Q-Exactive mass spectrometer operates with resolving powers between 17500 and 140000 FWHM (m/z 200). Nevertheless, a resolution of 17500FWHM is enough to dissociate ANA-a and PHE signals. Mass accuracy was satisfactory with values below 1 ppm reaching precision to the fourth decimal. Internal calibration with standard addition was achieved with the isotopically-labeled (D5) phenylalanine with good linearity (R(2)>0.999). Enhancement of signal to noise ratios relative to a standard triple-quadrupole method was demonstrated with lower detection and quantification limit values of 0.2 and 0.6 μg/L using the Q-Exactive. Accuracy and interday/intraday relative standard deviations were below 15%. The new method was applied to 8 different lake water samples with signs of cyanobacterial blooms. This work demonstrates the possibility of using an ultra-fast LDTD-APCI sample introduction system with an HRMS hybrid instrument for quantitative purposes with high selectivity in complex environmental matrices.
Collapse
Affiliation(s)
| | - Morgan Solliec
- Department of Chemistry, Université de Montréal, Montréal, QC, Canada
| | - Marc Sinotte
- Direction du Suivi de l'État de l'Environnement (DSEE), Ministère du développement durable, de l'environnement et de lutte aux changements climatiques (MDDELCC), Québec, QC, Canada
| | - Christian Deblois
- Centre d'expertise en analyse environnementale (CEAEQ), Ministère du développement durable, de l'environnement et de lutte aux changements climatiques (MDDELCC), Québec, QC, Canada
| | - Sébastien Sauvé
- Department of Chemistry, Université de Montréal, Montréal, QC, Canada.
| |
Collapse
|