1
|
Aktaş H, Kurek MA. Deep eutectic solvents for the extraction of polyphenols from food plants. Food Chem 2024; 444:138629. [PMID: 38341914 DOI: 10.1016/j.foodchem.2024.138629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 01/15/2024] [Accepted: 01/28/2024] [Indexed: 02/13/2024]
Abstract
Deep Eutectic Solvents (DESs) offer a promising, sustainable alternative for extracting polyphenols from food plants, known for their health benefits. Traditional extraction methods are often costly and involve toxic solvents. This review discusses the basic concepts, preparation techniques, and factors influencing the effective and safe use of DESs in polyphenol extraction. DESs' adaptability allows integration with other green extraction technologies, such as microwave- and ultrasound-assisted extractions, enhancing their efficiency. This adaptability demonstrates the potential of DESs in the sustainable extraction of bioactive compounds. Current research indicates that DESs could play a significant role in the sustainable procurement of these compounds, marking an important advancement in food science research and development. The review underscores DESs as a realistic, eco-friendly alternative in the realm of natural extraction technologies, offering a significant contribution to sustainable practices in food science.
Collapse
Affiliation(s)
- Havva Aktaş
- Department of Technique and Food Development, Institute of Human Nutrition Sciences, Warsaw University of Life Sciences (WULS-SGGW), Warsaw, Poland
| | - Marcin A Kurek
- Department of Technique and Food Development, Institute of Human Nutrition Sciences, Warsaw University of Life Sciences (WULS-SGGW), Warsaw, Poland.
| |
Collapse
|
2
|
Vállez-Gomis V, Benedé JL, Lara-Molina E, López-Nogueroles M, Chisvert A. A miniaturized stir bar sorptive dispersive microextraction method for the determination of bisphenols in follicular fluid using a magnetic covalent organic framework. Anal Chim Acta 2024; 1289:342215. [PMID: 38245199 DOI: 10.1016/j.aca.2024.342215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 12/05/2023] [Accepted: 01/03/2024] [Indexed: 01/22/2024]
Abstract
BACKGROUND Bisphenols, particularly bisphenol A (BPA), are the primary monomers used as additives in the manufacturing of many consumer products. The exposure to these compounds is related to endocrine-disrupting and reproductive effects, among others. For this reason, the development of analytical methods for their determination in biological matrixes is needed to monitor the population exposure to these compounds. Their quantification at ovarian level (i.e., follicular fluid) is interesting for the assessment of the bisphenol content to draw conclusions about infertility problems. However, the background does not meet all requirements by focusing mainly on BPA. RESULTS In this work, a miniaturized stir bar sorptive dispersive microextraction (mSBSDME) approach has been developed for the determination of BPA and eight analogues in follicular fluid. In the proposed method, the sample is previously cleaned-up using a zirconia-based solid-phase extraction cartridge, removing proteins and phospholipids, and then subjected to the mSBSDME for the preconcentration of the analytes. For this purpose, a magnetic covalent organic framework was used as sorbent. A Plackett-Burman design was applied to select the significant variables affecting the mSBSDME. Afterwards, the only significant variable (i.e., sorbent amount) was optimized. Under the optimized conditions, the proposed method was properly validated, and satisfactory analytical parameters in terms of linearity (up to 50 ng mL-1), enrichment factors (8.5-14.3), limits of detection in the low ng mL-1 range, and precision (relative standard deviations below 11.5 %) were obtained. Finally, the method was successfully applied to five samples, detecting BPA and other two analogues. SIGNIFICANCE This method expands the potential applicability of the mSBSDME to other low-availability complex matrixes, which would otherwise be difficult to analyze. Moreover, it offers a valuable tool for monitoring the female population's exposure to bisphenols with the final aim of evaluating if infertility problems of women might be associated to the exposure to these highly endocrine disrupting compounds.
Collapse
Affiliation(s)
- Víctor Vállez-Gomis
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, Burjassot, Valencia, 46100, Spain
| | - Juan L Benedé
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, Burjassot, Valencia, 46100, Spain
| | - Evelin Lara-Molina
- IVIRMA Barcelona, Barcelona, 08029, Spain; IVI Foundation IVIRMA Global, Biomedical Research Institute La Fe, Valencia, 46026, Spain
| | - Marina López-Nogueroles
- Analytical Unit Platform, Instituto de Investigación Sanitaria La Fe, Valencia, 46026, Spain
| | - Alberto Chisvert
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, Burjassot, Valencia, 46100, Spain.
| |
Collapse
|
3
|
Grau J, Chabowska A, Werner J, Zgoła-Grześkowiak A, Fabjanowicz M, Jatkowska N, Chisvert A, Płotka-Wasylka J. Deep eutectic solvents with solid supports used in microextraction processes applied for endocrine-disrupting chemicals. Talanta 2024; 268:125338. [PMID: 37931567 DOI: 10.1016/j.talanta.2023.125338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 10/19/2023] [Accepted: 10/23/2023] [Indexed: 11/08/2023]
Abstract
The determination of endocrine-disrupting chemicals (EDCs) has become one of the biggest challenges in Analytical Chemistry. Due to the low concentration of these compounds in different kinds of samples, it becomes necessary to employ efficient sample preparation methods and sensitive measurement techniques to achieve low limits of detection. This issue becomes even more struggling when the principles of the Green Analytical Chemistry are added to the equation, since finding an efficient sample preparation method with low damaging properties for health and environment may become laborious. Recently, deep eutectic solvents (DESs) have been proposed as the most promising green kind of solvents, but also with excellent analytical properties due to the possibility of custom preparation with different components to modify their polarity, viscosity or aromaticity among others. However, conventional extraction techniques using DESs as extraction solvents may not be enough to overcome challenges in analysing trace levels of EDCs. In this sense, combination of DESs with solid supports could be seen as a potential solution to this issue allowing, in different ways, to determine lower concentrations of EDCs. In that aim, the main purpose of this review is the study of the different strategies with solid supports used along with DESs to perform the determination of EDCs, comparing their advantages and drawbacks against conventional DES-based extraction methods.
Collapse
Affiliation(s)
- Jose Grau
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain; Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, G. Narutowicza 11/12, 80-233, Gdańsk, Poland.
| | - Aneta Chabowska
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, G. Narutowicza 11/12, 80-233, Gdańsk, Poland
| | - Justyna Werner
- Institute of Chemistry and Technical Electrochemistry, Faculty of Chemical Technology, Poznan University of Technology, Berdychowo 4, 60-965, Poznań, Poland
| | - Agnieszka Zgoła-Grześkowiak
- Institute of Chemistry and Technical Electrochemistry, Faculty of Chemical Technology, Poznan University of Technology, Berdychowo 4, 60-965, Poznań, Poland
| | - Magdalena Fabjanowicz
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, G. Narutowicza 11/12, 80-233, Gdańsk, Poland
| | - Natalia Jatkowska
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, G. Narutowicza 11/12, 80-233, Gdańsk, Poland; Department of Analytical Chemistry, University of Valencia, Valencia, 46100, Spain
| | - Alberto Chisvert
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain
| | - Justyna Płotka-Wasylka
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, G. Narutowicza 11/12, 80-233, Gdańsk, Poland; BioTechMed Center, Research Centre, Gdańsk University of Technology, G. Narutowicza St. 11/12, 80-233, Gdańsk, Poland.
| |
Collapse
|
4
|
Kechagia A, Manousi N, Kabir A, Furton KG, Zacharis CK. Fabricating a designer capsule phase microextraction platform based on sol-gel Carbowax 20M-zwitterionic ionic liquid composite sorbent for the extraction of lipid-lowering drugs from human urine samples. Mikrochim Acta 2023; 190:428. [PMID: 37796344 PMCID: PMC10556171 DOI: 10.1007/s00604-023-05998-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Accepted: 09/11/2023] [Indexed: 10/06/2023]
Abstract
A sol-gel Carbowax 20 M/3-[(3-Cholamidopropyl) dimethyl ammonio]-1-propanesulfonate composite sorbent-based capsule phase microextraction device has been fabricated and characterized for the determination of four statins (pravastatin, rosuvastatin, pitavastatin, and atorvastatin) in human urine. The presence of ionizable carboxyl functional groups in statins requires pH adjustment of the sample matrix to ensure that the target molecules are in their protonated form (pH should be 2 units below their pKa values) which not only is cumbersome but also risks unintended contamination of the sample. This challenge was addressed by introducing zwitterionic ionic liquid in addition to neutral, polar Carbowax 20 M polymer in the sol-gel-derived composite sorbent. As such, the composite zwitterionic multi-modal sorbent can simultaneously extract neutral, cationic, and anionic species. This particular attribute of the composite sorbent eliminates the necessity of the matrix pH adjustment and consequently simplifies the overall sample preparation workflow. Various experimental parameters such as the sample amount, extraction time, salt addition, stirring rate, and elution solvent type that may affect the extraction performance of the statins were investigated using a central composite design and the one-parameter-at-a-time approach. The analytes and the internal standard were separated on a C18 column with gradient elution using phosphate buffer (20 mM, pH 3) and acetonitrile as mobile phase. The analytes were detected at 237 nm. The method was validated, and linearity was observed in the range 0.10-2.0 μg mL-1 for all compounds. The method precision was better 9.9% and 10.4% for intra-day and inter-day, respectively, while the relative recoveries were acceptable, ranging between 83.4 and 116% in all cases. Method greenness was assessed using the ComplexGAPI index. Finally, the method's applicability was demonstrated in the determination of the statins in authentic human urine after oral administration of pitavastatin and rosuvastatin-containing tablets.
Collapse
Affiliation(s)
- Argyroula Kechagia
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece
| | - Natalia Manousi
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece
| | - Abuzar Kabir
- Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, Miami, FL, 33131, USA.
| | - Kenneth G Furton
- Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, Miami, FL, 33131, USA
| | - Constantinos K Zacharis
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece.
| |
Collapse
|
5
|
Hu X, Li H, Yang J, Wen X, Wang S, Pan M. Nanoscale Materials Applying for the Detection of Mycotoxins in Foods. Foods 2023; 12:3448. [PMID: 37761156 PMCID: PMC10528894 DOI: 10.3390/foods12183448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 09/11/2023] [Accepted: 09/13/2023] [Indexed: 09/29/2023] Open
Abstract
Trace amounts of mycotoxins in food matrices have caused a very serious problem of food safety and have attracted widespread attention. Developing accurate, sensitive, rapid mycotoxin detection and control strategies adapted to the complex matrices of food is crucial for in safeguarding public health. With the continuous development of nanotechnology and materials science, various nanoscale materials have been developed for the purification of complex food matrices or for providing response signals to achieve the accurate and rapid detection of various mycotoxins in food products. This article reviews and summarizes recent research (from 2018 to 2023) on new strategies and methods for the accurate or rapid detection of mold toxins in food samples using nanoscale materials. It places particular emphasis on outlining the characteristics of various nanoscale or nanostructural materials and their roles in the process of detecting mycotoxins. The aim of this paper is to promote the in-depth research and application of various nanoscale or structured materials and to provide guidance and reference for the development of strategies for the detection and control of mycotoxin contamination in complex matrices of food.
Collapse
Affiliation(s)
- Xiaochun Hu
- Key Laboratory of Food Quality and Health of Tianjin, Tianjin University of Science and Technology, Tianjin 300457, China; (X.H.); (H.L.); (J.Y.); (X.W.); (S.W.)
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Huilin Li
- Key Laboratory of Food Quality and Health of Tianjin, Tianjin University of Science and Technology, Tianjin 300457, China; (X.H.); (H.L.); (J.Y.); (X.W.); (S.W.)
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Jingying Yang
- Key Laboratory of Food Quality and Health of Tianjin, Tianjin University of Science and Technology, Tianjin 300457, China; (X.H.); (H.L.); (J.Y.); (X.W.); (S.W.)
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Xintao Wen
- Key Laboratory of Food Quality and Health of Tianjin, Tianjin University of Science and Technology, Tianjin 300457, China; (X.H.); (H.L.); (J.Y.); (X.W.); (S.W.)
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Shuo Wang
- Key Laboratory of Food Quality and Health of Tianjin, Tianjin University of Science and Technology, Tianjin 300457, China; (X.H.); (H.L.); (J.Y.); (X.W.); (S.W.)
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Mingfei Pan
- Key Laboratory of Food Quality and Health of Tianjin, Tianjin University of Science and Technology, Tianjin 300457, China; (X.H.); (H.L.); (J.Y.); (X.W.); (S.W.)
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China
| |
Collapse
|
6
|
Raoufi A, Raoufi AM, Ismailzadeh A, Soleimani Rad E, Kiaeefar A. Application of hollow fiber-protected liquid-phase microextraction combined with GC-MS in determining Endrin, Chlordane, and Dieldrin in rice samples. ENVIRONMENTAL GEOCHEMISTRY AND HEALTH 2023; 45:5261-5277. [PMID: 37115414 DOI: 10.1007/s10653-023-01570-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 04/06/2023] [Indexed: 06/19/2023]
Abstract
This paper introduces a novel and minimized sample preparation technique based on hollow fiber-protected liquid-phase microextraction that can be used in joint with gas chromatography-mass spectrometry (GC-MS) detection to extract three organochlorine pesticides-Endrin, Chlordane, and Dieldrin-from rice samples. To that end, a single-walled carbon nanotube (SWCNT) and a proper ionic liquid (IL) were ultrasonically dispersed and injected into the lumen of hollow fiber as the extraction phase for preconcentrating and extracting the target analytes from the rice samples. The effects of the type of nanoparticles, ILs, and desorption solvent on the efficiency of extracting the analytes were investigated based on the one-factor-at-a-time (OFAT) approach. In addition, other parameters influencing the extraction procedure were optimized using an experimental design that decreased the number of experiments, reagent consumption, and costs. Under optimized conditions, the limits of detection and quantification in determining mentioned pesticides varied between 0.019-0.029 and 0.064-0.098 ng mL-1, respectively. The calibration graphs to measure Endrin, Chlordane, and Dieldrin were linear over the concentration range of 0.064-13.2, 0.098-16.7, and 0.092-11.4 ng mL-1, respectively. The relative standard deviations for inter-day and intra-day analysis were below 7.06 and 4.75% for the triplicate determination of three organochlorine pesticides. Besides, the relative recoveries and standard deviations of Endrin, Chlordane, and Dieldrin for analyzing several Iranian rice samples were between 86.0-92.9% and 4.5-5.8%, respectively. The results were compared with other similar works in literature, proving that the proposed method is efficient and useful for routine monitoring of organochlorine compounds in food samples.
Collapse
Affiliation(s)
- Arastou Raoufi
- Department of Chemistry, Mashhad Branch, Islamic Azad University, Mashhad, Iran.
| | - Amir Mahdi Raoufi
- Department of Chemistry, Faculty of Science, Payame Noor University, Mashhad, Iran
| | - Amir Ismailzadeh
- Department of Chemistry, Mashhad Branch, Islamic Azad University, Mashhad, Iran
- Young Researchers and Elite Club, Mashhad Branch, Islamic Azad University, Mashhad, Iran
| | - Ehsan Soleimani Rad
- Department of Chemistry, Mashhad Branch, Islamic Azad University, Mashhad, Iran
| | - Ali Kiaeefar
- Department of Chemistry, Shiley Center for Science and Technology, San Diego, CA, USA
| |
Collapse
|
7
|
Azorín C, Benedé JL, Chisvert A, Salvador A. Trace determination of tetrahydrocannabinol (THC) in cosmetic products by stir bar sorptive dispersive microextraction followed by liquid chromatography-tandem mass spectrometry. Talanta 2023; 253:123934. [PMID: 36152610 DOI: 10.1016/j.talanta.2022.123934] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 09/06/2022] [Accepted: 09/08/2022] [Indexed: 12/13/2022]
Abstract
An analytical method for the determination of tetrahydrocannabinol (THC) at trace level in cosmetics is presented. As psychoactive compound, the presence of THC in consumer products should be avoided. However, it might be unintentionally present in cannabidiol-rich or hemp-based products by contamination or isomerization of cannabidiol. Due to the low concentrations expected, a sensitive and selective method is necessary for the analytical control of these products. In this sense, the presented method is based on stir bar sorptive dispersive microextraction (SBSDME) followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). In this work, a magnetic composite made of CoFe2O4 magnetic nanoparticles embedded in a commercial reverse-phase polymer (Strata™-X-RP) was employed as magnetic sorbent material taking advantage of its affinity to the target analyte. Under the optimized conditions, the method was validated and showed good analytical features in terms of linearity (at least up to 10 ng mL-1), limits of detection and quantification (2.2 and 7.2 ng g-1, respectively) and repeatability (RSD <10%). Moreover, relative recoveries between 99 and 109% were obtained, showing matrix effects were negligible using deuterated THC (THC-D3) as surrogate. This new approach was successfully applied to ten commercially-available cosmetic samples of different matrices, thus showing it is suitable for the analytical control of THC in cosmetic products. The proposed methodology overcomes some of the drawbacks of the previous works with the same purpose, such as the higher limits of detection, time-consuming procedures, and consumption of large volumes of organic solvents.
Collapse
Affiliation(s)
- Cristian Azorín
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100 Burjassot, Valencia, Spain
| | - Juan L Benedé
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100 Burjassot, Valencia, Spain
| | - Alberto Chisvert
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100 Burjassot, Valencia, Spain.
| | - Amparo Salvador
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100 Burjassot, Valencia, Spain
| |
Collapse
|
8
|
Covalent organic framework in situ grown on Fe 3O 4 hollow microspheres for stir bar sorptive-dispersive microextraction of triazole pesticides. Mikrochim Acta 2022; 190:34. [PMID: 36538150 DOI: 10.1007/s00604-022-05613-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Accepted: 12/03/2022] [Indexed: 01/07/2023]
Abstract
Based on covalent organic framework (COF) 1,3,5-tris-(4-formylphenyl)benzene-benzidine (TFPB-BD) in situ grown on Fe3O4 hollow microspheres and combined with gas chromatography-flame thermionic detector, a rapid and simple stir bar sorptive-dispersive microextraction method was developed for the determination of five triazole pesticides (paclobutrazol, hexaconazole, flusilazole, propiconazole, and tebuconazole). The synthesized TFPB-BD/Fe3O4 microspheres were characterized by transmission electron microscope, vibrating sample magnetometer, and thermogravimetric analysis, which showed that the material has strong magnetism and higher load capacity of COF. Under optimal conditions, the extraction equilibrium could be achieved within 9 min with detection limits of 0.17-1.48 μg L-1 (S/N = 3) and a linear range of 5-1000 μg L-1. The developed method was applied to the determination of trace triazole pesticides in apples, pears, and cabbages with recoveries from 81 to 117%.
Collapse
|
9
|
Wang J, Feng J, Sun M, Lian Y, Wang M, Qiao L. Sulfonic acid-functionalized covalent organic frameworks as the coating for stir bar sorptive extraction of fluoroquinolones in milk samples. Mikrochim Acta 2022; 190:5. [PMID: 36469152 DOI: 10.1007/s00604-022-05534-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 10/10/2022] [Indexed: 12/12/2022]
Abstract
Sulfonic acid-functionalized covalent organic frameworks (COF-SO3) as a coating of stir bar sorptive extraction (SBSE) for capturing three fluoroquinolones from milk have been developed. The COF-SO3 material was characterized by X-ray diffraction, scanning electron microscopy, X-ray photoelectron spectroscopy, and infrared spectroscopy. Milk without any typical treatments like protein precipitation and defatting was only diluted five times with water for test. Combined with high-performance liquid chromatography (HPLC), a SBSE-HPLC method was established for detecting fluoroquinolones in milk samples. The corresponding wide linear ranges (4.00-500.0 µg L-1), low detection limits (1.20-2.62 µg L-1), good test repeatability (RSD < 5.2%), and acceptable enrichment factors (56.2-61.5) were implemented for three fluoroquinolones. The analytical method was applied to determine trace targets and provided satisfactory results. Furthermore, the research displayed satisfied reproducibility for bar-to-bar (RSD < 6.5%) and batch-to-batch (RSD < 8.6%) tests.
Collapse
Affiliation(s)
- Jiarui Wang
- College of Food Science and Engineering, College of Plant Protection, Shandong Agricultural University, Taian, 271018, People's Republic of China
| | - Juanjuan Feng
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, People's Republic of China
| | - Min Sun
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, People's Republic of China.
| | - Yujing Lian
- College of Food Science and Engineering, College of Plant Protection, Shandong Agricultural University, Taian, 271018, People's Republic of China
| | - Minglin Wang
- College of Food Science and Engineering, College of Plant Protection, Shandong Agricultural University, Taian, 271018, People's Republic of China
| | - Luqin Qiao
- College of Food Science and Engineering, College of Plant Protection, Shandong Agricultural University, Taian, 271018, People's Republic of China.
| |
Collapse
|
10
|
Fei Z, Xie D, Wang M, Zhang Y, Zhang H, Du Q, Jin P. Enhanced biotransformation of bioactive components and volatile compounds of bamboo (Phyllostachys glauca McClure) leaf juice fermented by probiotic Streptococcus thermophiles. Lebensm Wiss Technol 2022. [DOI: 10.1016/j.lwt.2022.114363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
11
|
Vállez-Gomis V, Trujillo-Rodríguez MJ, Benedé JL, Pasán J, Pino V, Chisvert A. The metal-organic framework PCN-250 for the extraction of endocrine disrupting compounds in human urine by stir bar sorptive dispersive microextraction. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
|
12
|
Vállez-Gomis V, Carchano-Olcina S, Benedé JL, Chisvert A, Salvador A. Entrapment of magnetic nanoparticles into poly(divinylbenzene-co-N-vinylpyrrolidone) copolymer for the determination of prohibited and restricted fragrance ingredients in cosmetic products. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
13
|
New challenges in sample preparation: Miniaturized stir bar sorptive dispersive microextraction as a high-throughput and feasible approach for low-availability sample preparation. Anal Chim Acta 2022; 1238:340627. [DOI: 10.1016/j.aca.2022.340627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 10/14/2022] [Accepted: 11/11/2022] [Indexed: 11/17/2022]
|
14
|
Mussagy CU, Pereira JFB, Santos-Ebinuma VC, Pessoa A, Raghavan V. Insights into using green and unconventional technologies to recover natural astaxanthin from microbial biomass. Crit Rev Food Sci Nutr 2022; 63:11211-11225. [PMID: 35766952 DOI: 10.1080/10408398.2022.2093326] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Microorganisms such as bacteria, microalgae and fungi, are natural and rich sources of several valuable bioactive antioxidant's compounds, including carotenoids. Among the carotenoids with antioxidant properties, astaxanthin can be highlighted due to its pharmaceutical, feed, food, cosmetic and biotechnological applications. The best-known producers of astaxanthin are yeast and microalgae cells that biosynthesize this pigment intracellularly, requiring efficient and sustainable downstream procedures for its recovery. Conventional multi-step procedures usually involve the consumption of large amounts of volatile organic compounds (VOCs), which are regarded as toxic and hazardous chemicals. Considering these environmental issues, this review is focused on revealing the potential of unconventional extraction procedures [viz., Supercritical Fluid Extraction (SFE), Ultrasound-Assisted Extraction (UAE), Microwave-Assisted Extraction (MAE), High-Pressure Homogenization (HPH)] combined with alternative green solvents (biosolvents, eutectic solvents and ionic liquids) for the recovery of microbial-based astaxanthin from microalgae (such as Haematococcus pluvialis) and yeast (such as Phaffia rhodozyma) cells. The principal advances in the area, process bottlenecks, solvent selection and strategies to improve the recovery of microbial astaxanthin are emphasized. The promising recovery yields using these environmentally friendly procedures in lab-scale are good indications and directions for their effective use in biotechnological processes for the production of commercial feed and food ingredients like astaxanthin.
Collapse
Affiliation(s)
- Cassamo U Mussagy
- Escuela de Agronomía, Facultad de Ciencias Agronómicas y de los Alimentos, Pontificia Universidad Católica de Valparaíso, Quillota, Chile
| | - Jorge F B Pereira
- Department of Chemical Engineering, Rua Sílvio Lima, Pólo II - Pinhal de Marrocos, Univ. Coimbra, CIEPQPF, Coimbra, Portugal
| | - Valéria C Santos-Ebinuma
- Department of Engineering of Bioprocesses and Biotechnology, School of Pharmaceutical Sciences, São Paulo State University (UNESP), Araraquara, SP, Brazil
| | - Adalberto Pessoa
- Department of Pharmaceutical-Biochemical Technology, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, Brazil
| | - Vijaya Raghavan
- Department of Bioresource Engineering, Faculty of Agricultural and Environmental Sciences, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
15
|
Grau J, Benedé JL, Chisvert A, Salvador A. A high-throughput magnetic-based pipette tip microextraction as an alternative to conventional pipette tip strategies: Determination of testosterone in human saliva as a proof-of-concept. Anal Chim Acta 2022; 1221:340117. [DOI: 10.1016/j.aca.2022.340117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 06/20/2022] [Accepted: 06/22/2022] [Indexed: 11/01/2022]
|
16
|
Shao CY, Zhang Y, Lv HP, Zhang ZF, Zeng JM, Peng QH, Zhu Y, Lin Z. Aromatic profiles and enantiomeric distributions of chiral odorants in baked green teas with different picking tenderness. Food Chem 2022; 388:132969. [PMID: 35447588 DOI: 10.1016/j.foodchem.2022.132969] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 04/07/2022] [Accepted: 04/10/2022] [Indexed: 11/04/2022]
Abstract
Suitable picking tenderness is an essential prerequisite for manufacturing tea. However, the influence of picking tenderness of fresh tea leaves on the aromatic components is still unclear. In this study, aromatic profiles and chiral odorants in fresh tea leaves and corresponding baked green teas with five levels of tenderness of two representative cultivars were analysed using stir bar sorptive extraction-gas chromatography-mass spectrometry. cis-Linalool oxide (furanoid) and methyl salicylate exhibited significantly increasing trends as samples of all series matured. The content of most chiral odorants was significantly high in the mature samples, and significant content variations of all enantiomers during baked green tea processing could be observed with different trends according to their precursors. In particular, the enantiomeric ratios of most chiral odorants were less influenced by the picking tenderness and processing, while drying (limonene), spreading and fixation (α-terpineol), and spreading (dihydroactinidiolide) influenced the chiral distribution of the aforementioned odorants.
Collapse
Affiliation(s)
- Chen-Yang Shao
- Key Laboratory of Tea Biology and Resource Untilization, Ministry of Agriculture, Tea Research Institute, Chinese Academy of Agricultural Sciences, Hangzhou 310008, China; Graduate School of Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Yue Zhang
- Key Laboratory of Tea Biology and Resource Untilization, Ministry of Agriculture, Tea Research Institute, Chinese Academy of Agricultural Sciences, Hangzhou 310008, China
| | - Hai-Peng Lv
- Key Laboratory of Tea Biology and Resource Untilization, Ministry of Agriculture, Tea Research Institute, Chinese Academy of Agricultural Sciences, Hangzhou 310008, China
| | - Zhi-Fang Zhang
- Key Laboratory of Tea Biology and Resource Untilization, Ministry of Agriculture, Tea Research Institute, Chinese Academy of Agricultural Sciences, Hangzhou 310008, China
| | - Jian-Ming Zeng
- Key Laboratory of Tea Biology and Resource Untilization, Ministry of Agriculture, Tea Research Institute, Chinese Academy of Agricultural Sciences, Hangzhou 310008, China
| | - Qun-Hua Peng
- Key Laboratory of Tea Biology and Resource Untilization, Ministry of Agriculture, Tea Research Institute, Chinese Academy of Agricultural Sciences, Hangzhou 310008, China
| | - Yin Zhu
- Key Laboratory of Tea Biology and Resource Untilization, Ministry of Agriculture, Tea Research Institute, Chinese Academy of Agricultural Sciences, Hangzhou 310008, China.
| | - Zhi Lin
- Key Laboratory of Tea Biology and Resource Untilization, Ministry of Agriculture, Tea Research Institute, Chinese Academy of Agricultural Sciences, Hangzhou 310008, China.
| |
Collapse
|
17
|
Alvand N, Baghdadi M, Alimoradi M, Marjani A, Isfahani TM. Metal-Phase Microextraction (MPME) as a Novel Solvent-Free and Green Sample Preparation Technique: Determination of Cadmium in Infant Formula and Real Water Samples. FOOD ANAL METHOD 2022. [DOI: 10.1007/s12161-022-02259-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
18
|
Duque A, Grau J, Benedé JL, Alonso RM, Campanero MA, Chisvert A. Low toxicity deep eutectic solvent-based ferrofluid for the determination of UV filters in environmental waters by stir bar dispersive liquid microextraction. Talanta 2022; 243:123378. [DOI: 10.1016/j.talanta.2022.123378] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 03/09/2022] [Accepted: 03/09/2022] [Indexed: 01/25/2023]
|
19
|
Gouma V, Pournara AD, Manos MJ, Giokas DL. Fabric phase sorpitive extraction and passive sampling of ultraviolet filters from natural waters using a zirconium metal organic framework-cotton composite. J Chromatogr A 2022; 1670:462945. [DOI: 10.1016/j.chroma.2022.462945] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 03/04/2022] [Accepted: 03/07/2022] [Indexed: 11/27/2022]
|
20
|
Bagheri AR, Aramesh N, Gong Z, Cerda V, Lee HK. Two-dimensional materials as a platform in extraction methods: A review. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116606] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
|
21
|
Zatrochová S, Martínez-Pérez-Cejuela H, Catalá-Icardo M, Simó-Alfonso EF, Lhotská I, Šatínský D, Herrero-Martínez JM. Development of hybrid monoliths incorporating metal–organic frameworks for stir bar sorptive extraction coupled with liquid chromatography for determination of estrogen endocrine disruptors in water and human urine samples. Mikrochim Acta 2022; 189:92. [PMID: 35132465 PMCID: PMC8821068 DOI: 10.1007/s00604-022-05208-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 01/27/2022] [Indexed: 11/19/2022]
Abstract
A novel coating based on hybrid monolith with metal–organic framework (MOF) onto conventional Teflon-coated magnetic stir bars was developed. For this purpose, the external surface of the Teflon stir bar was firstly vinylized in order to immobilize a glycidyl methacrylate (GMA)–based polymer onto the magnet. Then, an amino-modified MOF of type MIL-101 (NH2-MIL-101(Al)) was covalently attached to the GMA-based monolith. After the synthesis process, several parameters affecting extraction of target estrogens by stir bar sorptive extraction (SBSE) including pH, ionic strength, extraction time, stirring rate, desorption solvent, and desorption time were also investigated. The resulting hybrid monolith was evaluated as SBSE sorbent for extraction of three estrogens (estrone, 17β-estradiol, estriol) and synthetic 17β-ethinylestradiol from water and human urine samples followed by HPLC with fluorescence detection (excitation and emission wavelengths, 280 and 310 nm, respectively). Under the optimal experimental conditions, the analytical figures of the method were established, achieving satisfactory limits of detection in the range of 0.015–0.58 µg L−1, recovery results ranging from 70 to 95% with RSD less than 6%, and precision values (intra- and inter-extraction units) below 6%.
Collapse
|
22
|
Lemos VA, Barreto JA, Santos LB, de Assis RDS, Novaes CG, Cassella RJ. In-syringe dispersive liquid-liquid microextraction. Talanta 2022; 238:123002. [PMID: 34857335 DOI: 10.1016/j.talanta.2021.123002] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 09/23/2021] [Accepted: 10/26/2021] [Indexed: 10/20/2022]
Abstract
Dispersive liquid-liquid microextraction (DLLME) has recently been widely used in the separation and preconcentration of various chemical species. Among the various approaches using DLLME are systems that use a syringe as an extraction environment. In this review, details of some methods that use this approach are presented. The ways to promote dispersion, analytical characteristics, and the advantages and disadvantages of the methods, among other aspects, are discussed critically. Finally, some trends in the use of in-syringe microextraction systems are described.
Collapse
Affiliation(s)
- Valfredo Azevedo Lemos
- Universidade Estadual do Sudoeste da Bahia, Laboratório de Química Analítica, Campus de Jequié, 45208-091, Jequié, Bahia, Brazil; Universidade Federal da Bahia, Programa de Pós-Graduação em Química, Campus Universitário de Ondina, 40170-280, Salvador, Bahia, Brazil.
| | - Jeferson Alves Barreto
- Universidade Estadual do Sudoeste da Bahia, Laboratório de Química Analítica, Campus de Jequié, 45208-091, Jequié, Bahia, Brazil; Universidade Federal Fluminense, Departamento de Química Analítica, Outeiro de São João Batista s/n, 24020-141, Niterói, Rio de Janeiro, Brazil
| | - Luana Bastos Santos
- Universidade Estadual do Sudoeste da Bahia, Laboratório de Química Analítica, Campus de Jequié, 45208-091, Jequié, Bahia, Brazil; Universidade Federal da Bahia, Programa de Pós-Graduação em Química, Campus Universitário de Ondina, 40170-280, Salvador, Bahia, Brazil
| | - Rosivan Dos Santos de Assis
- Universidade Federal da Bahia, Programa de Pós-Graduação em Química, Campus Universitário de Ondina, 40170-280, Salvador, Bahia, Brazil
| | - Cleber Galvão Novaes
- Universidade Estadual do Sudoeste da Bahia, Laboratório de Química Analítica, Campus de Jequié, 45208-091, Jequié, Bahia, Brazil
| | - Ricardo J Cassella
- Universidade Federal Fluminense, Departamento de Química Analítica, Outeiro de São João Batista s/n, 24020-141, Niterói, Rio de Janeiro, Brazil
| |
Collapse
|
23
|
Vállez-Gomis V, Exojo-Trujillo S, Benedé JL, Chisvert A, Salvador A. Stir bar sorptive-dispersive microextraction by a poly(methacrylic acid-co-ethylene glycol dimethacrylate)-based magnetic sorbent for the determination of tricyclic antidepressants and their main active metabolites in human urine. Mikrochim Acta 2022; 189:52. [PMID: 35000010 PMCID: PMC8742809 DOI: 10.1007/s00604-021-05156-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 12/20/2021] [Indexed: 12/19/2022]
Abstract
A poly(methacrylic acid-co-ethylene glycol dimethacrylate)-based magnetic sorbent was used for the rapid and sensitive determination of tricyclic antidepressants and their main active metabolites in human urine. This material was characterized by magnetism measurements, zeta potential, scanning electron microscopy, nitrogen adsorption-desorption isotherms, and thermogravimetric analysis. The proposed analytical method is based on stir bar sorptive-dispersive microextraction (SBSDME) followed by liquid chromatography-tandem mass spectrometry. The main parameters involved in the extraction step were optimized by using the response surface methodology as a multivariate optimization method, whereas a univariate approach was employed to study the desorption parameters. Under the optimized conditions, the proposed method was properly validated showing good linearity (at least up to 50 ng mL-1) and enrichment factors (13-22), limits of detection and quantification in the low ng L-1 range (1.4-7.0 ng L-1), and good intra- and inter-day repeatability (relative standard deviations below 15%). Matrix effects were observed for the direct analysis of urine samples, but they were negligible when a 1:1 v/v dilution with deionized water was performed. Finally, the method was successfully applied to human urine samples from three volunteers, one of them consuming a prescribed drug for depression that tested positive for clomipramine and its main active metabolite. Quantitative relative recoveries (80-113%) were obtained by external calibration. The present work expands the applicability of the SBSDME to new analytes and new types of magnetic sorbents.
Collapse
Affiliation(s)
- Víctor Vállez-Gomis
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain
| | - Sara Exojo-Trujillo
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain
| | - Juan L Benedé
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain
| | - Alberto Chisvert
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain.
| | - Amparo Salvador
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain
| |
Collapse
|
24
|
Nadal JC, Catalá-Icardo M, Borrull F, Herrero-Martínez JM, Marcé RM, Fontanals N. Weak anion-exchange mixed-mode materials to selectively extract acidic compounds by stir bar sorptive extraction from environmental waters. J Chromatogr A 2021; 1663:462748. [PMID: 34965484 DOI: 10.1016/j.chroma.2021.462748] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 12/10/2021] [Accepted: 12/11/2021] [Indexed: 12/14/2022]
Abstract
In this study, the first example of a polytetrafluoroethylene (PTFE)-based magnet coated with weak anion exchange (WAX) monolith as novel support for stir bar sorptive extraction (SBSE) is presented. Firstly, the PTFE magnets were properly modified and vinylized in order to immobilize polymer monoliths onto its surface. Then, a glycidyl methacrylate monolith was prepared and modified with ethylenediamine (EDA) to create weak anion exchanger via ring opening reaction of epoxy groups. The prepared covalently immobilized EDA-modified monoliths onto PTFE magnet exhibited good stability and reusability. Application of resulting material as stir bar for SBSE was investigated for a series of acidic compounds that includes acesulfame, saccharin, diclofenac or ibuprofen, among others as target compounds. Firstly, the SBSE conditions were optimized to promote the WAX interactions with the target compounds achieving recoveries from 37 to 75% and enable the selective extraction of these compounds as it provided values of% matrix effect from 17 to -13% when they were determined by SBSE followed by liquid chromatography - tandem mass spectrometry. The analytical methodology, was then validated and applied for the determination of the target solutes in environmental water samples, which were found at concentration up to 2500 ng L-1 in river waters.
Collapse
Affiliation(s)
- Joan Carles Nadal
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel·lí Domingo 1, Tarragona 43007, Spain
| | - Mónica Catalá-Icardo
- Instituto de Investigación para la Gestión Integrada de Zonas Costeras, Campus de Gandia, Universitat Politècnica de València, C/ Paranimf 1, Grao de Gandia, Valencia 46730, Spain
| | - Francesc Borrull
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel·lí Domingo 1, Tarragona 43007, Spain
| | | | - Rosa Maria Marcé
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel·lí Domingo 1, Tarragona 43007, Spain.
| | - Núria Fontanals
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel·lí Domingo 1, Tarragona 43007, Spain
| |
Collapse
|
25
|
|
26
|
Abstract
The evaluation of volatiles in food is an important aspect of food production. It gives knowledge about the quality of foods and their relationship to consumers’ choices. Alcohols, aldehydes, acids, esters, terpenes, pyrazines, and furans are the main chemical groups that are involved in aroma formation. They are products of food processing: thermal treatment, fermentation, storage, etc. Food aroma is a mixture of varied molecules. Because of this, the analysis of aroma composition can be challenging. The four main steps can be distinguished in the evaluation of the volatiles in the food matrix as follows: (1) isolation and concentration; (2) separation; (3) identification; and (4) sensory characterization. The most commonly used techniques to separate a fraction of volatiles from non-volatiles are solid-phase micro-(SPME) and stir bar sorptive extractions (SBSE). However, to study the active components of food aroma by gas chromatography with olfactometry detector (GC-O), solvent-assisted flavor evaporation (SAFE) is used. The volatiles are mostly separated on GC systems (GC or comprehensive two-dimensional GCxGC) with the support of mass spectrometry (MS, MS/MS, ToF–MS) for chemical compound identification. Besides omics techniques, the promising part could be a study of aroma using electronic nose. Therefore, the main assumptions of volatolomics are here described.
Collapse
|
27
|
Qin P, Han L, Zhang X, Li M, Li D, Lu M, Cai Z. MIL-101(Fe)-derived magnetic porous carbon as sorbent for stir bar sorptive-dispersive microextraction of sulfonamides. Mikrochim Acta 2021; 188:340. [PMID: 34523015 DOI: 10.1007/s00604-021-04993-w] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Accepted: 08/18/2021] [Indexed: 01/07/2023]
Abstract
Using MIL-101(Fe) as the source of carbon and Fe, a magnetic porous carbon (MPC) material with Fe3C nanoparticles encapsulated in porous carbon was prepared through one-pot pyrolysis under N2 atmosphere. With MPC as adsorption material, a stir bar sorptive-dispersive microextraction (SBSDME) method was proposed to extract and preconcentrate sulfonamides (SAs) prior to HPLC-DAD determination. To investigate their extraction ability, different MPC materials were prepared under different carbonization temperatures (600, 700, 800, 900, and 1000 °C). The material prepared under 900 °C (MPC-900) exhibited the highest extraction ability for SAs. The as-prepared MPC materials were also characterized by Raman spectroscopy, scanning electron microscopy, X-ray photoelectron spectroscopy, zeta potential, and other techniques. The main parameters that affect extraction were systematically studied. Under optimal conditions, favorable linearity (R2 ≥ 0.9938) and detection limits (0.02-0.04 ng mL-1) of sulfonamides were obtained. The average recoveries for spiked milk and lake water samples ranged from 76.9 to 109% and from 75.4 to 118% with RSDs of 3.10-9.63% and 1.71-11.3%, respectively. Sulfameter and sulfisoxazole were detected in milk sample. Sulfisoxazole was detected in the lake water sample. The MPC-900 material demonstrated excellent reusability. It can be reused 24 times with peak areas having no obvious decline. The method can be applied to extract ultra-trace compounds in complex sample matrices. Schematic presentation of a stir bar sorptive-dispersive microextraction (SBSDME) by using magnetic porous carbon (MPC) composites as sorbent combined with high-performance liquid chromatography for sensitive analysis of sulfonamides in milk and lake water samples.
Collapse
Affiliation(s)
- Peige Qin
- Henan International Joint Laboratory of Medicinal Plants Utilization, College of Chemistry and Chemical Engineering, Henan University, Kaifeng, 475004, Henan, China
| | - Lizhen Han
- Henan International Joint Laboratory of Medicinal Plants Utilization, College of Chemistry and Chemical Engineering, Henan University, Kaifeng, 475004, Henan, China
| | - Xiaowan Zhang
- Henan International Joint Laboratory of Medicinal Plants Utilization, College of Chemistry and Chemical Engineering, Henan University, Kaifeng, 475004, Henan, China
| | - Mengyuan Li
- Henan International Joint Laboratory of Medicinal Plants Utilization, College of Chemistry and Chemical Engineering, Henan University, Kaifeng, 475004, Henan, China
| | - Dan Li
- Henan International Joint Laboratory of Medicinal Plants Utilization, College of Chemistry and Chemical Engineering, Henan University, Kaifeng, 475004, Henan, China
| | - Minghua Lu
- Henan International Joint Laboratory of Medicinal Plants Utilization, College of Chemistry and Chemical Engineering, Henan University, Kaifeng, 475004, Henan, China.
| | - Zongwei Cai
- State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, Hong Kong, SAR, China
| |
Collapse
|
28
|
Recent Advances in Sample Preparation for Cosmetics and Personal Care Products Analysis. Molecules 2021; 26:molecules26164900. [PMID: 34443488 PMCID: PMC8399500 DOI: 10.3390/molecules26164900] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 08/10/2021] [Accepted: 08/11/2021] [Indexed: 11/19/2022] Open
Abstract
The use of cosmetics and personal care products is increasing worldwide. Their high matrix complexity, together with the wide range of products currently marketed under different forms imply a challenge for their analysis, most of them requiring a sample pre-treatment step before analysis. Classical sample preparation methodologies involve large amounts of organic solvents as well as multiple steps resulting in large time consumption. Therefore, in recent years, the trends have been moved towards the development of simple, sustainable, and environmentally friendly methodologies in two ways: (i) the miniaturization of conventional procedures allowing a reduction in the consumption of solvents and reagents; and (ii) the development and application of sorbent- and liquid-based microextraction technologies to obtain a high analyte enrichment, avoiding or significantly reducing the use of organic solvents. This review provides an overview of analytical methodology during the last ten years, placing special emphasis on sample preparation to analyse cosmetics and personal care products. The use of liquid–liquid and solid–liquid extraction (LLE, SLE), ultrasound-assisted extraction (UAE), solid-phase extraction (SPE), pressurized liquid extraction (PLE), matrix solid-phase extraction (MSPD), and liquid- and sorbent-based microextraction techniques will be reviewed. The most recent advances and future trends including the development of new materials and green solvents will be also addressed.
Collapse
|
29
|
Grau J, Benedé JL, Chisvert A. Polydopamine-coated magnetic nanoparticles for the determination of nitro musks in environmental water samples by stir bar sorptive-dispersive microextraction. Talanta 2021; 231:122375. [PMID: 33965039 DOI: 10.1016/j.talanta.2021.122375] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 02/28/2021] [Accepted: 03/18/2021] [Indexed: 10/21/2022]
Abstract
Magnetic-based microextraction approaches have gained popularity in recent years due to the magnetic properties of the extraction phases allowing to handle them easier and more efficiently. This work describes a magnetic-based analytical method for the determination of the family of nitro musks in environmental water samples. These compounds have been of great concern due to their environmental impacts and potential health effects. The method is based on stir bar sorptive-dispersive microextraction (SBSDME) as extraction approach, prior to thermal desorption coupled to gas chromatography-mass spectrometry analysis (TD-GC-MS). For this purpose, polydopamine-coated cobalt ferrite magnetic nanoparticles (CoFe2O4@PDA) were used as extraction material. The main parameters involved in the extraction procedure (i.e., sorbent amount, extraction time and ionic strength) as well as in the thermal desorption step (i.e., temperature and desorption time) were evaluated in order to obtain the highest sensitivity. Under the selected conditions, the method showed good linearity, limits of detection and quantification in the low ng L-1 range, intra- and inter-day repeatability with RSD <15%, and high enrichment factors (178-640). Finally, the method was applied to four environmental water samples of different origin. Relative recovery values ranging from 91 to 120% highlighted that the matrices under consideration do not affect the extraction process. This work constitutes the first time in which nitro musks compounds were selectively extracted by taking advantage the high potential that magnetic-based microextraction techniques offer, specially SBSDME.
Collapse
Affiliation(s)
- José Grau
- Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain
| | - Juan L Benedé
- Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain
| | - Alberto Chisvert
- Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain.
| |
Collapse
|