1
|
Chen J, Li A, Dai J, Fu Q, Yu Z, Xu S, Zhang W, Li P. Optimal submicron roughness for balancing degradation behavior, immune modulation, and microbial adhesion on zinc-based barrier membranes. BIOMATERIALS ADVANCES 2025; 169:214146. [PMID: 39799898 DOI: 10.1016/j.bioadv.2024.214146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2024] [Revised: 11/29/2024] [Accepted: 12/06/2024] [Indexed: 01/15/2025]
Abstract
Metallic zinc (Zn) has been demonstrated to be a promising alternative to barrier membrane materials for guided bone regeneration. Surface roughness significantly affects the properties of degradable Zn-based metals, especially within the Janus micro-environments of tissue regeneration. However, the effects of optimal surface roughness on Zn remain unknown. In this study, pure Zn surfaces were fabricated with three roughness scales: nano (Sa < 0.1 μm), submicron (Sa: 0.5-1.0 μm), and micron (Sa > 1.0 μm). Submicron-scale pure Zn exhibited a moderate degradation rate in simulated body fluids, and no deep corrosion pits appeared on the surface. By contrast, the degradation rate of nano-surface pure Zn decreased significantly, while localized corrosion tended to appear on micron surfaces. In addition, the degradation rate of Zn with different roughness was overall accelerated in artificial saliva, accompanied by varying degradation morphologies. Co-culturing with submicron samples inhibited macrophage polarization to the M1 phenotype. Nano-scale surfaces promoted macrophage polarization towards the M1 phenotype and exhibited significantly reduced antibacterial rates compared to rougher surfaces. These findings demonstrate that submicron-scale pure Zn could be an optimal choice for barrier membrane surfaces.
Collapse
Affiliation(s)
- Jiahao Chen
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - An Li
- Department of Periodontology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Jingtao Dai
- Department of Orthodontics, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China
| | - Qingyun Fu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Zhentao Yu
- Institute of Advanced Wear & Corrosion Resistant and Functional Materials, Jinan University, Guangzhou 510632, China
| | - Shulan Xu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China.
| | - Wentai Zhang
- Dongguan Key Laboratory of Smart Biomaterials and Regenerative Medicine, The Tenth Affiliated Hospital of Southern Medical University, Dongguan, Guangdong 523000, China.
| | - Ping Li
- Department of Prosthodontics, School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou 510180, China; Guangzhou Key Laboratory of Basic and Applied Research of Oral Regenerative Medicine, Guangzhou Medical University, Guangzhou 510180, China.
| |
Collapse
|
2
|
Jiang X, Guo J, Zhang Y, Zuo H, Bao Y, Liu N, Guo M, Wu R, Chen Q. Electrophoretic deposition of Ag-Cu-CTS coatings on porous titanium with photothermal-responsive antibacterial effect. J Colloid Interface Sci 2025; 682:1116-1126. [PMID: 39667331 DOI: 10.1016/j.jcis.2024.11.244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2024] [Revised: 11/19/2024] [Accepted: 11/29/2024] [Indexed: 12/14/2024]
Abstract
Porous architecture of titanium implants offers significant advantages in promoting osseointegration and mitigating the "stress shielding" effect. However, challenges remain in enhancing vascularization and preventing infection, especially given the complexities of modifying the intricate surface structure of porous titanium (PT). This study introduces a novel surface modification technique of PT using anti-gravity perfusion electrophoretic deposition (EPD) technique to fabricate antibacterial coatings containing silver (Ag) and copper (Cu) co-doped mesoporous silica nanoparticles (Ag-Cu@MSN) and chitosan binder on the surface of PT. The developed coating exhibits rapid and stable photothermal response to 808 nm near-infrared (NIR) light, leading to a localized temperature rise and triggered release of Ag and Cu ions for synergistic bactericidal efficacy against both E. coli and S. aureus. In vitro studies further demonstrated that the coated PT significantly promoted the proliferation of mouse calvaria pre-osteoblast (MC3T3-E1) and human umbilical vein endothelial cells (HUVECs), with a notable increase in HUVECs migration and angiogenesis, attributable to the presence of Cu ions. This innovative EPD-based coating strategy offers a promising avenue for developing uniform, photothermally-activated antibacterial surfaces on PT implants, with substantial implications for advancing clinical bone repair applications.
Collapse
Affiliation(s)
- Xiaodan Jiang
- State Key Laboratory of Solidification Processing, School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Jiabao Guo
- State Key Laboratory of Solidification Processing, School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Yuhan Zhang
- State Key Laboratory of Solidification Processing, School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Hubao Zuo
- School of Mechanics, Civil Engineering and Architecture, Northwestern Polytechnical University, Xi'an 710072, China
| | - Yuanqi Bao
- State Key Laboratory of Solidification Processing, School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Nian Liu
- State Key Laboratory for Crop Stress Resistance and High-Efficiency Production and College of Life Sciences, Northwest A&F University, Yangling 712100, China
| | - Mingna Guo
- State Key Laboratory of Solidification Processing, School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Ronghai Wu
- State Key Laboratory of Solidification Processing, School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Qiang Chen
- State Key Laboratory of Solidification Processing, School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an 710072, China.
| |
Collapse
|
3
|
Ma L, Li H. Study on the Synergistic Effects of Cu and Sr on Biodegradable Zn Alloys. ACS APPLIED MATERIALS & INTERFACES 2024; 16:52116-52129. [PMID: 39298545 DOI: 10.1021/acsami.4c13841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
Bone defect repair and postoperative infections are among the most challenging issues faced by orthopedic surgeons. Thus, the antibacterial agent Cu and the osteogenic promoter Sr have been widely incorporated into biodegradable alloys separately. However, to the best of our knowledge, the synergistic effects of Cu and Sr on zinc alloys have not been investigated. Therefore, we have developed a series of novel Zn-4Cu-xSr (x = 0.05, 0.1, and 0.3 wt %) alloys. Our results showed that the addition of Cu and Sr significantly increased the strength of pure zinc while maintaining a certain level of ductility. Plastic deformation further enhanced the strength and ductility of the alloys. The tensile strength of HR Zn-4Cu-xSr alloys remains between 233.34 ± 1.31 MPa and 235.81 ± 3.0 MPa, with elongation values ranging from 45.7 ± 1.56% to 49.6 ± 6.22%. The HE Zn-4Cu-0.05Sr alloy exhibits a high elongation of 95.05 ± 11.1%. Furthermore, the HE Zn-4Cu-0.1Sr alloy demonstrates the best overall mechanical performance with ultimate tensile strength (σuts), yield strength (σys), and elongation (ε) values of 252.73 ± 0.12 MPa, 181.0 ± 0.79 MPa, and 42.8 ± 1.13%, respectively. The corrosion rate of HE Zn-4Cu-xSr alloys increases with an increase in Sr content. All samples exhibit satisfactory cytocompatibility with the cells displaying a healthy spindle-like morphology. In vitro antibacterial tests show that the HE Zn-4Cu-xSr alloys exhibit significant antibacterial effects against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli), with the antibacterial properties strengthening as the Sr content increases. Therefore, this study demonstrates the tremendous potential application of Zn-4Cu-xSr alloys in biodegradable zinc alloys for bone fracture fixation and repair.
Collapse
Affiliation(s)
- Luqing Ma
- School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Huafang Li
- School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China
| |
Collapse
|
4
|
Wei X, Meng J, Ma S, Li Y, Qing H, Peng X, Zhao Q. Degradation protection and enhanced biocompatibility of Mg alloys pretreated with plasma proteins. J Biomed Mater Res A 2024; 112:1004-1014. [PMID: 38327244 DOI: 10.1002/jbm.a.37681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 01/17/2024] [Accepted: 01/19/2024] [Indexed: 02/09/2024]
Abstract
After implantation of the Mg alloy in the human body, the adsorption of plasma protein on surface will cause a series of cell reactions and affect the degradation of Mg alloys. Herein, in vitro biological reactions of the ZK60 and AZ31 Mg alloys are analyzed in plasma protein environment. Combined with mass spectrometry analysis of the type of adsorbed proteins, it is shown that proteins such as fibrinogen, vitronectin, fibronectin, and prothrombin are prone to get adsorbed on the surface of the alloys than other proteins, leading to the promotion of MG63 cell adhesion and proliferation. The effect of selected proteins (fibrinogen, fibronectin, and prothrombin) on degradation of ZK60 and AZ31 Mg alloys is investigated using immersion tests. The degradation of AZ31 Mg alloy is significantly restrained with the presence of proteins. This is due to the protein adsorption effect on the sample surface. The molecular dynamics simulation results indicate that both fibrinogen and fibronectin tend to adsorb onto the AZ31 rather than ZK60, forming a stable protein layer on the AZ31 Mg alloy retarding the degradation of the samples. As to ZK60 alloy, the addition of protein inhibits the degradation in the short term, however, the degradation increases after a long time of immersion. This phenomenon is particularly pronounced in fibronectin solution.
Collapse
Affiliation(s)
- Xian Wei
- School of Life Science, Beijing Institute of Technology, Beijing, China
- School of Physics, Beijing Institute of Technology, Beijing, China
- Department of Science, Taiyuan Institute of Technology, Taiyuan, China
| | - Jiajia Meng
- School of Physics, Beijing Institute of Technology, Beijing, China
| | - Sujie Ma
- School of Physics, Beijing Institute of Technology, Beijing, China
| | - Yanchun Li
- School of Physics, Beijing Institute of Technology, Beijing, China
| | - Hong Qing
- School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Xubiao Peng
- School of Physics, Beijing Institute of Technology, Beijing, China
| | - Qing Zhao
- School of Physics, Beijing Institute of Technology, Beijing, China
- National Key Laboratory of Science and Technology on Materials under Shock and Impact, Beijing, China
| |
Collapse
|
5
|
Varsavas SD, Michalec P, Khalifa M, Li P, Spintzyk S. Cytocompatibility of Polymers for Skin-Contact Applications Produced via Pellet Extrusion. J Funct Biomater 2024; 15:179. [PMID: 39057301 PMCID: PMC11278057 DOI: 10.3390/jfb15070179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2024] [Revised: 06/21/2024] [Accepted: 06/24/2024] [Indexed: 07/28/2024] Open
Abstract
Orthoses and prostheses (O&P) play crucial roles in assisting individuals with limb deformities or amputations. Proper material selection for these devices is imperative to ensure mechanical robustness and biocompatibility. While traditional manufacturing methods have limitations in terms of customization and reproducibility, additive manufacturing, particularly pellet extrusion (PEX), offers promising advancements. In applications involving direct contact with the skin, it is essential for materials to meet safety standards to prevent skin irritation. Hence, this study investigates the biocompatibility of different thermoplastic polymers intended for skin-contact applications manufactured through PEX. Surface morphology analysis revealed distinct characteristics among materials, with TPE-70ShA exhibiting notable irregularities. Cytotoxicity assessments using L929 fibroblasts indicated non-toxic responses for most materials, except for TPE-70ShA, highlighting the importance of material composition in biocompatibility. Our findings underscore the significance of adhering to safety standards in material selection and manufacturing processes for medical devices. While this study provides valuable insights, further research is warranted to investigate the specific effects of individual ingredients and explore additional parameters influencing material biocompatibility. Overall, healthcare practitioners must prioritize patient safety by meticulously selecting materials and adhering to regulatory standards in O&P manufacturing.
Collapse
Affiliation(s)
- Sakine Deniz Varsavas
- ADMiRE Research Center, Carinthia University of Applied Sciences, Europastraße 4, 9524 Villach, Austria (P.M.); (S.S.)
| | - Paweł Michalec
- ADMiRE Research Center, Carinthia University of Applied Sciences, Europastraße 4, 9524 Villach, Austria (P.M.); (S.S.)
| | - Mohammed Khalifa
- Competence Center for Wood Composites and Wood Chemistry, Wood K Plus, Klagenfurter Str. 87–89, 9300 St. Veit an der Glan, Austria;
| | - Ping Li
- Department of Prosthodontics, School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou 510180, China
- Guangzhou Key Laboratory of Basic and Applied Research of Oral Regenerative Medicine, Guangzhou Medical University, Guangzhou 510180, China
| | - Sebastian Spintzyk
- ADMiRE Research Center, Carinthia University of Applied Sciences, Europastraße 4, 9524 Villach, Austria (P.M.); (S.S.)
| |
Collapse
|
6
|
Istrate B, Cojocaru FD, Henea ME, Balan V, Șindilar EV, Verestiuc L, Munteanu C, Solcan C. In Vitro and In Vivo Analysis of the Mg-Ca-Zn Biodegradable Alloys. J Funct Biomater 2024; 15:166. [PMID: 38921539 PMCID: PMC11204402 DOI: 10.3390/jfb15060166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Revised: 05/28/2024] [Accepted: 06/12/2024] [Indexed: 06/27/2024] Open
Abstract
The objective of this work was to analyze the in vitro and in vivo tests of a novel Mg-based biodegradable alloy-Mg-0.5%Ca-with various amounts of Zn (0.5, 1, 1.5, 2.0, and 3.0 wt.%). In terms of in vitro biocompatibility, MTT and Calcein-AM cell viability assays, performed on the MG-63 cell line through the extract method, revealed that all five alloy extracts are non-cytotoxic at an extraction ratio of 0.025 g alloy per mL of cell culture medium. In the in vivo histological analysis, Mg-0.5Ca-1.5Zn demonstrated exceptional potential for stimulating bone remodeling and showed excellent biocompatibility. It was observed that Mg-0.5Ca-0.5Zn, Mg-0.5Ca-1.5Zn, and Mg-0.5Ca-3Zn displayed good biocompatibility. Furthermore, the histological examination highlighted the differentiation of periosteal cells into chondrocytes and subsequent bone tissue replacement through endochondral ossification. This process highlighted the importance of the initial implant's integrity and the role of the periosteum. In summary, Mg-0.5Ca-1.5Zn stands out as a promising candidate for bone regeneration and osseointegration, supported by both in vitro and in vivo findings.
Collapse
Affiliation(s)
- Bogdan Istrate
- Mechanical Engineering, Mechatronics and Robotics Department, Mechanical Engineering Faculty, “Gheorghe Asachi” Technical University of Iasi, 700050 Iasi, Romania;
| | - Florina-Daniela Cojocaru
- Biomedical Sciences Department, Faculty of Medical Bioengineering, Grigore T. Popa University of Medicine and Pharmacy of Iasi, 9-13 Kogalniceanu Street, 700454 Iasi, Romania; (V.B.); (L.V.)
| | - Mădălina-Elena Henea
- Surgery Unit, Clinics Department, Faculty of Veterinary Medicine, Iasi University of Life Sciences, Ion Ionescu de la Brad, 700490 Iasi, Romania; (M.-E.H.); (C.S.)
| | - Vera Balan
- Biomedical Sciences Department, Faculty of Medical Bioengineering, Grigore T. Popa University of Medicine and Pharmacy of Iasi, 9-13 Kogalniceanu Street, 700454 Iasi, Romania; (V.B.); (L.V.)
| | - Eusebiu-Viorel Șindilar
- Surgery Unit, Clinics Department, Faculty of Veterinary Medicine, Iasi University of Life Sciences, Ion Ionescu de la Brad, 700490 Iasi, Romania; (M.-E.H.); (C.S.)
| | - Liliana Verestiuc
- Biomedical Sciences Department, Faculty of Medical Bioengineering, Grigore T. Popa University of Medicine and Pharmacy of Iasi, 9-13 Kogalniceanu Street, 700454 Iasi, Romania; (V.B.); (L.V.)
| | - Corneliu Munteanu
- Mechanical Engineering, Mechatronics and Robotics Department, Mechanical Engineering Faculty, “Gheorghe Asachi” Technical University of Iasi, 700050 Iasi, Romania;
- Technical Sciences Academy of Romania, 26 Dacia Blvd., 030167 Bucharest, Romania
| | - Carmen Solcan
- Surgery Unit, Clinics Department, Faculty of Veterinary Medicine, Iasi University of Life Sciences, Ion Ionescu de la Brad, 700490 Iasi, Romania; (M.-E.H.); (C.S.)
| |
Collapse
|
7
|
Lv Q, Song W, Chu J, Li G, Han Y, Marfavi Z, Zhang G, Wu Y, Lin Y, Sun K, Xu H, Tao K. An Indocyanine Green-Based Nanocluster for Imaging Orthodox Endometriosis Lesions with Negative Contrast. ACS APPLIED MATERIALS & INTERFACES 2024; 16:25909-25922. [PMID: 38716677 DOI: 10.1021/acsami.4c04131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2024]
Abstract
Indocyanine green (ICG), as the sole near-infrared dye FDA-approved, is limited in biomedical applications because of its poor photostability, lack of targeting, and rapid removal in vivo. Herein, we presented a nanoformulation of poly-l-lysine-indocyanine green-hyaluronic acid (PIH) and demonstrated that it can image orthodox endometriosis (EM) lesions with a negative contrast. The PIH nanocluster, with an average diameter of approximately 200 nm, exhibited improved fluorescence photostability and antioxidant ability compared to free ICG. In the in vivo imaging, EM lesions were visualized, featuring apparent voids and clear boundaries. After colocalizing with the green fluorescent protein, we concluded that the contrast provided by PIH peaked at 4 h postinjection and was observable for at least 8 h. The negative contrast, clear boundaries, and enhanced observable time might be due to the low permeation of PIH to lesions and the enhanced retention on the surfaces of lesions. Thus, our findings suggest an ICG-based nanoprobe with the potential to diagnose abdominal diseases.
Collapse
Affiliation(s)
- Quanjie Lv
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering Shanghai Jiao Tong University, Shanghai 200240, P.R. China
| | - Weizhou Song
- International Peace Maternity and Child Health Hospital, Shanghai Key Laboratory of Embryo Original Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai 200240, P.R. China
| | - Jing Chu
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering Shanghai Jiao Tong University, Shanghai 200240, P.R. China
| | - Guojing Li
- International Peace Maternity and Child Health Hospital, Shanghai Key Laboratory of Embryo Original Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai 200240, P.R. China
| | - Yijun Han
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering Shanghai Jiao Tong University, Shanghai 200240, P.R. China
| | - Zeinab Marfavi
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering Shanghai Jiao Tong University, Shanghai 200240, P.R. China
| | - Gengxin Zhang
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering Shanghai Jiao Tong University, Shanghai 200240, P.R. China
| | - Yongjie Wu
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering Shanghai Jiao Tong University, Shanghai 200240, P.R. China
| | - Yu Lin
- International Peace Maternity and Child Health Hospital, Shanghai Key Laboratory of Embryo Original Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai 200240, P.R. China
| | - Kang Sun
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering Shanghai Jiao Tong University, Shanghai 200240, P.R. China
| | - Hong Xu
- International Peace Maternity and Child Health Hospital, Shanghai Key Laboratory of Embryo Original Diseases, Shanghai Jiao Tong University School of Medicine, Shanghai 200240, P.R. China
| | - Ke Tao
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering Shanghai Jiao Tong University, Shanghai 200240, P.R. China
| |
Collapse
|
8
|
Yuan K, Deng C, Tan L, Wang X, Yan W, Dai X, Du R, Zheng Y, Zhang H, Wang G. Structural and temporal dynamics analysis of zinc-based biomaterials: History, research hotspots and emerging trends. Bioact Mater 2024; 35:306-329. [PMID: 38362138 PMCID: PMC10867564 DOI: 10.1016/j.bioactmat.2024.01.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 01/13/2024] [Accepted: 01/17/2024] [Indexed: 02/17/2024] Open
Abstract
Objectives To examine the 16-year developmental history, research hotspots, and emerging trends of zinc-based biodegradable metallic materials from the perspective of structural and temporal dynamics. Methods The literature on zinc-based biodegradable metallic materials in WoSCC was searched. Historical characteristics, the evolution of active topics and development trends in the field of zinc-based biodegradable metallic materials were analyzed using the bibliometric tools CiteSpace and HistCite. Results Over the past 16 years, the field of zinc-based biodegradable metal materials has remained in a hotspot stage, with extensive scientific collaboration. In addition, there are 45 subject categories and 51 keywords in different research periods, and 80 papers experience citation bursts. Keyword clustering anchored 3 emerging research subfields, namely, #1 plastic deformation #4 additive manufacturing #5 surface modification. The keyword alluvial map shows that the longest-lasting research concepts in the field are mechanical property, microstructure, corrosion behavior, etc., and emerging keywords are additive manufacturing, surface modification, dynamic recrystallization, etc. The most recent research on reference clustering has six subfields. Namely, #0 microstructure, #2 sem, #3 additive manufacturing, #4 laser powder bed fusion, #5 implant, and #7 Zn-1Mg. Conclusion The results of the bibliometric study provide the current status and trends of research on zinc-based biodegradable metallic materials, which can help researchers identify hot spots and explore new research directions in the field.
Collapse
Affiliation(s)
- Kunshan Yuan
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400030, China
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
| | - Chengchen Deng
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400030, China
| | - Lili Tan
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400030, China
| | - Xiangxiu Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400030, China
| | - Wenhua Yan
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400030, China
| | - Xiaozhen Dai
- School of Biosciences and Technology, Chengdu Medical College, Chengdu, 610500, China
| | - Ruolin Du
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400030, China
| | - Yufeng Zheng
- Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing, 100871, China
| | - Haijun Zhang
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
- Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, 200092, China
| | - Guixue Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400030, China
- JinFeng Laboratory, Chongqing, 401329, China
- School of Biosciences and Technology, Chengdu Medical College, Chengdu, 610500, China
| |
Collapse
|
9
|
Cao X, Wang X, Chen J, Geng X, Tian H. 3D Printing of a Porous Zn-1Mg-0.1Sr Alloy Scaffold: A Study on Mechanical Properties, Degradability, and Biosafety. J Funct Biomater 2024; 15:109. [PMID: 38667566 PMCID: PMC11051303 DOI: 10.3390/jfb15040109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/09/2024] [Accepted: 04/10/2024] [Indexed: 04/28/2024] Open
Abstract
In recent years, the use of zinc (Zn) alloys as degradable metal materials has attracted considerable attention in the field of biomedical bone implant materials. This study investigates the fabrication of porous scaffolds using a Zn-1Mg-0.1Sr alloy through a three-dimensional (3D) printing technique, selective laser melting (SLM). The results showed that the porous Zn-1Mg-0.1Sr alloy scaffold featured a microporous structure and exhibited a compressive strength (CS) of 33.71 ± 2.51 MPa, a yield strength (YS) of 27.88 ± 1.58 MPa, and an elastic modulus (E) of 2.3 ± 0.8 GPa. During the immersion experiments, the immersion solution showed a concentration of 2.14 ± 0.82 mg/L for Zn2+ and 0.34 ± 0.14 mg/L for Sr2+, with an average pH of 7.61 ± 0.09. The porous Zn-1Mg-0.1Sr alloy demonstrated a weight loss of 12.82 ± 0.55% and a corrosion degradation rate of 0.36 ± 0.01 mm/year in 14 days. The Cell Counting Kit-8 (CCK-8) assay was used to check the viability of the cells. The results showed that the 10% and 20% extracts significantly increased the activity of osteoblast precursor cells (MC3T3-E1), with a cytotoxicity grade of 0, which indicates safety and non-toxicity. In summary, the porous Zn-1Mg-0.1Sr alloy scaffold exhibits outstanding mechanical properties, an appropriate degradation rate, and favorable biosafety, making it an ideal candidate for degradable metal bone implants.
Collapse
Affiliation(s)
- Xiangyu Cao
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China; (X.C.); (X.W.); (J.C.)
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing 100191, China
| | - Xinguang Wang
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China; (X.C.); (X.W.); (J.C.)
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing 100191, China
| | - Jiazheng Chen
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China; (X.C.); (X.W.); (J.C.)
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing 100191, China
| | - Xiao Geng
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China; (X.C.); (X.W.); (J.C.)
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing 100191, China
| | - Hua Tian
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China; (X.C.); (X.W.); (J.C.)
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing 100191, China
| |
Collapse
|
10
|
Han X, Sharma N, Xu Z, Krajewski S, Li P, Spintzyk S, Lv L, Zhou Y, Thieringer FM, Rupp F. A balance of biocompatibility and antibacterial capability of 3D printed PEEK implants with natural totarol coating. Dent Mater 2024; 40:674-688. [PMID: 38388252 DOI: 10.1016/j.dental.2024.02.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 12/22/2023] [Accepted: 02/12/2024] [Indexed: 02/24/2024]
Abstract
OBJECTIVE Polyetheretherketone (PEEK), a biomaterial with appropriate bone-like mechanical properties and excellent biocompatibility, is widely applied in cranio-maxillofacial and dental applications. However, the lack of antibacterial effect is an essential drawback of PEEK material and might lead to infection and osseointegration issues. This study aims to apply a natural antibacterial agent, totarol coating onto the 3D printed PEEK surface and find an optimized concentration with balanced cytocompatibility, osteogenesis, and antibacterial capability. METHODS In this study, a natural antibacterial agent, totarol, was applied as a coating to fused filament fabrication (FFF) 3D printed PEEK surfaces at a series of increasing concentrations (1 mg/ml, 5 mg/ml, 10 mg/ml, 15 mg/ml, and 20 mg/ml). The samples were then evaluated for cytocompatibility with L929 fibroblast and SAOS-2 osteoblast using live/dead staining and CCK-8 assay. The antibacterial capability was assessed by crystal violet staining, live/dead staining, and scanning electron microscopy (SEM) utilizing the oral primary colonizer S. gordonii and isolates of mixed oral bacteria in a stirring system simulating the oral environment. The appropriate safe working concentration for totarol coating is selected based on the results of the cytocompatibility and antibacterial test. Subsequently, the influence on osteogenic differentiation was evaluated by alkaline phosphatase (ALP) and alizarin red staining (ARS) analysis of pre-osteoblasts. RESULTS Our results showed that the optimal concentration of totarol solution for promising antibacterial coating was approximately 10 mg/ml. Such surfaces could play an excellent antibacterial role by inducing a contact-killing effect with an inhibitory effect against biofilm development without affecting the healing of soft and hard tissues around FFF 3D printed PEEK implants or abutments. SIGNIFICANCE This study indicates that the totarol coated PEEK has an improved antibacterial effect with excellent biocompatibility providing great clinical potential as an orthopedic/dental implant/abutment material.
Collapse
Affiliation(s)
- Xingting Han
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, NHC Key Laboratory of Digital Technology of Stomatology, 22 Zhongguancun Avenue South, Haidian District, Beijing 100081, China; Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology; Shanghai Engineering Research Center of Advanced Dental Technology and Materials, Shanghai 200011, China; University Hospital Tübingen, Department of Medical Materials Science and Technology, Osianderstr. 2-8, Tübingen D-72076, Germany
| | - Neha Sharma
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland; Department of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, Basel, Switzerland
| | - Zeqian Xu
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology; Shanghai Engineering Research Center of Advanced Dental Technology and Materials, Shanghai 200011, China; University Hospital Tübingen, Department of Medical Materials Science and Technology, Osianderstr. 2-8, Tübingen D-72076, Germany.
| | - Stefanie Krajewski
- University Hospital Tübingen, Department of Medical Materials Science and Technology, Osianderstr. 2-8, Tübingen D-72076, Germany
| | - Ping Li
- University Hospital Tübingen, Department of Medical Materials Science and Technology, Osianderstr. 2-8, Tübingen D-72076, Germany; Department of Prosthodontics, School and Hospital of Stomatology, Guangzhou Medical University, Guangzhou, Guangdong 510182, China
| | - Sebastian Spintzyk
- University Hospital Tübingen, Department of Medical Materials Science and Technology, Osianderstr. 2-8, Tübingen D-72076, Germany; ADMiRE Research Center - Additive Manufacturing, Intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, Villach, Austria
| | - Longwei Lv
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, NHC Key Laboratory of Digital Technology of Stomatology, 22 Zhongguancun Avenue South, Haidian District, Beijing 100081, China
| | - Yongsheng Zhou
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, NHC Key Laboratory of Digital Technology of Stomatology, 22 Zhongguancun Avenue South, Haidian District, Beijing 100081, China
| | - Florian M Thieringer
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland; Department of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, Basel, Switzerland
| | - Frank Rupp
- University Hospital Tübingen, Department of Medical Materials Science and Technology, Osianderstr. 2-8, Tübingen D-72076, Germany
| |
Collapse
|
11
|
Tan J, Li S, Sun C, Bao G, Liu M, Jing Z, Fu H, Sun Y, Yang Q, Zheng Y, Wang X, Yang H. A Dose-Dependent Spatiotemporal Response of Angiogenesis Elicited by Zn Biodegradation during the Initial Stage of Bone Regeneration. Adv Healthc Mater 2024; 13:e2302305. [PMID: 37843190 DOI: 10.1002/adhm.202302305] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 10/09/2023] [Indexed: 10/17/2023]
Abstract
Zinc (Zn) plays a crucial role in bone metabolism and imbues biodegradable Zn-based materials with the ability to promote bone regeneration in bone trauma. However, the impact of Zn biodegradation on bone repair, particularly its influence on angiogenesis, remains unexplored. This study reveals that Zn biodegradation induces a consistent dose-dependent spatiotemporal response in angiogenesis,both in vivo and in vitro. In a critical bone defect model, an increase in Zn release intensity from day 3 to 10 post-surgery is observed. By day 10, the CD31-positive area around the Zn implant significantly surpasses that of the Ti implant, indicating enhanced angiogenesis. Furthermore,angiogenesis exhibits a distance-dependent pattern closely mirroring the distribution of Zn signals from the implant. In vitro experiments demonstrate that Zn extraction fosters the proliferation and migration of human umbilical vein endothelial cells and upregulates the key genes associated with tube formation, such as HIF-1α and VEGF-A, peaking at a concentration of 22.5 µM. Additionally, Zn concentrations within the range of 11.25-45 µM promote the polarization of M0-type macrophages toward the M2-type, while inhibiting polarization toward the M1-type. These findings provide essential insights into the biological effects of Zn on bone repair, shedding light on its potential applications.
Collapse
Affiliation(s)
- Junlong Tan
- Key Laboratory of Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, 37 Xueyuan Rd, Beijing, 100191, China
| | - Shuang Li
- Key Laboratory of Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, 37 Xueyuan Rd, Beijing, 100191, China
| | - Chaoyang Sun
- Key Laboratory of Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, 37 Xueyuan Rd, Beijing, 100191, China
| | - Guo Bao
- Department of Reproduction and Physiology, National Research Institute for Family Planning, Beijing, 100081, China
| | - Meijing Liu
- Key Laboratory of Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, 37 Xueyuan Rd, Beijing, 100191, China
| | - Zehao Jing
- Beijing Key Laboratory of Spinal Disease Research, Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, P. R. China
| | - Hanwei Fu
- School of Materials Science and Engineering, Beihang University, 37 Xueyuan Rd, Beijing, China
| | - Yanhua Sun
- Shandong Provincial Key Laboratory of Microparticles Drug Delivery Technology, Qilu Pharmaceutical Co. Ltd., Jinan, 250100, China
| | - Qingmin Yang
- Shandong Provincial Key Laboratory of Microparticles Drug Delivery Technology, Qilu Pharmaceutical Co. Ltd., Jinan, 250100, China
| | - Yufeng Zheng
- Beijing Advanced Innovation Center for Materials Genome Engineering and School of Materials Science and Engineering, Peking University, Beijing, 100871, China
| | - Xiaogang Wang
- Key Laboratory of Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, 37 Xueyuan Rd, Beijing, 100191, China
| | - Hongtao Yang
- Key Laboratory of Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, 37 Xueyuan Rd, Beijing, 100191, China
| |
Collapse
|
12
|
Chen S, Du T, Zhang H, Qi J, Zhang Y, Mu Y, Qiao A. Methods for improving the properties of zinc for the application of biodegradable vascular stents. BIOMATERIALS ADVANCES 2024; 156:213693. [PMID: 37992478 DOI: 10.1016/j.bioadv.2023.213693] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 11/02/2023] [Accepted: 11/03/2023] [Indexed: 11/24/2023]
Abstract
Biodegradable stents can support vessels for an extended period, maintain vascular patency, and progressively degrade once vascular remodeling is completed, thereby reducing the constraints of traditional metal stents. An ideal degradable stent must have good mechanical properties, degradation behavior, and biocompatibility. Zinc has become a new type of biodegradable metal after magnesium and iron, owing to its suitable degradation rate and good biocompatibility. However, zinc's poor strength and ductility make it unsuitable as a vascular stent material. Therefore, this paper reviewed the primary methods for improving the overall properties of zinc. By discussing the mechanical properties, degradation behavior, and biocompatibility of various improvement strategies, we found that alloying is the most common, simple, and effective method to improve mechanical properties. Deformation processing can further improve the mechanical properties by changing the microstructures of zinc alloys. Surface modification is an important means to improve the biological activity, blood compatibility and corrosion resistance of zinc alloys. Meanwhile, structural design can not only improve the mechanical properties of the vascular stents, but also endow the stents with special properties such as negative Poisson 's ratio. Manufacturing zinc alloys with excellent degradation properties, improved mechanical properties and strong biocompatibility and exploring their mechanism of interaction with the human body remain areas for future research.
Collapse
Affiliation(s)
- Shiliang Chen
- Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Tianming Du
- Faculty of Environment and Life, Beijing University of Technology, Beijing, China.
| | - Hanbing Zhang
- Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Jing Qi
- Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Yanping Zhang
- Faculty of Environment and Life, Beijing University of Technology, Beijing, China
| | - Yongliang Mu
- School of Metallurgy, Northeastern University, Shenyang, China
| | - Aike Qiao
- Faculty of Environment and Life, Beijing University of Technology, Beijing, China.
| |
Collapse
|
13
|
Palai D, Siva Prasad P, Satpathy B, Das S, Das K. Development of Zn-2Cu- xMn/Mg Alloys for Orthopedic Applications: Mechanical Performance to In Vitro Degradation under Different Physiological Environments. ACS Biomater Sci Eng 2023; 9:6058-6083. [PMID: 37774322 DOI: 10.1021/acsbiomaterials.3c00641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/01/2023]
Abstract
Zinc (Zn) and its alloys are considered futuristic biodegradable materials for their acceptable mechanical properties, suitable corrosion rate, and good biocompatibility. In this study, we report newly developed biodegradable Zn-2Cu-xMn/Mg (x = 0, 0.1, and 0.5) alloys, aiming to achieve good mechanical strength with excellent elongation, desirable wear resistance, and suitable corrosion rate. The effect of Mn/Mg addition on the structural, mechanical, wear, and degradation behaviors of the Zn-2Cu-xMn/Mg alloys was thoroughly investigated. Degradation and tribological behaviors of the alloys were explored in the presence of simulated body fluid (SBF), Dulbecco's modified Eagle medium (DMEM), and DMEM with a 10% fetal bovine serum (FBS) solution. Alloy elements and hot rolling improve their mechanical properties significantly due to precipitation hardening, grain refinement, and solid solution strengthening owing to the formation of MnZn13 and Mg2Zn11 phases. Among all the alloys, the Zn-2Cu-0.5Mn alloy achieved the highest ultimate tensile strength (UTS) of ∼405 MPa and yield strength (YS) of ∼293 MPa with an excellent elongation of ∼51%. The corrosion behavior of the alloys as determined by a potentiodynamic polarization study under different solutions follows the sequence Zn-2Cu < Zn-2Cu-0.5Mn < Zn-2Cu-0.1Mn < Zn-2Cu-0.1Mg < Zn-2Cu-0.5Mg. The corrosion rate by immersion testing for 30 and 90 days also follows the same sequence. The corrosion rate in different solutions follows the order SBF > DMEM + 10%FBS > DMEM. The addition of Mn/Mg also improves the wear resistance and slows the wear rate under wet conditions. The bending test results also indicate the highest bending strength of ∼375 MPa for the Zn-2Cu-0.5Mn alloy, among all the alloys. The bending and tensile strengths deteriorate continuously after the immersion for 30 and 90 days in the solution of SBF, DMEM, and DMEM + 10%FBS. Therefore, the Zn-2Cu-xMn/Mg (x = 0.1 and 0.5) alloys can be considered potential biodegradable implant materials.
Collapse
Affiliation(s)
- Debajyoti Palai
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - P Siva Prasad
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Bangmaya Satpathy
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Siddhartha Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Karabi Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
14
|
Gruber S, Nickel A. Toxic or not toxic? The specifications of the standard ISO 10993-5 are not explicit enough to yield comparable results in the cytotoxicity assessment of an identical medical device. FRONTIERS IN MEDICAL TECHNOLOGY 2023; 5:1195529. [PMID: 37388758 PMCID: PMC10304299 DOI: 10.3389/fmedt.2023.1195529] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 06/05/2023] [Indexed: 07/01/2023] Open
Abstract
Background Medical device manufacturers are obliged to prove the biocompatibility of their products when they come into contact with the human body. The requirements for the biological evaluation of medical devices are specified by the international standard series ISO 10993. Part five of this series describes the performance of in vitro cytotoxicity tests. This test evaluates the effects of medical device use on cell health. The existence of the specific standard suggests that the tests will produce reliable and comparable results. However, the ISO 10993-5 offers wide latitude in the test specifications. In the past, we noticed inconsistencies of the results from different laboratories. Objective To determine if the specifications of the standard ISO 10993-5 are explicit to ensure the comparability of test results and, if not, identify potential influencing factors. Methods An interlaboratory comparison was conducted for the in vitro cytotoxicity test according to ISO 10993-5. Fifty-two international laboratories evaluated the cytotoxicity for two unknown samples. One was polyethylene (PE) tubing, which is expected to be non-cytotoxic and the other was polyvinyl chloride (PVC) tubing, for which a cytotoxic potential was presumed. All laboratories were asked to perform an elution test with predefined extraction specifications. The other test parameters were freely chosen by the laboratories according to the guidelines set by the standard. Results To our surprise only 58 percent of the participating laboratories identified the cytotoxic potential of both materials as expected. Particularly for PVC a considerable variation of the results between the laboratories was observed [mean = 43 ± 30 (SD), min = 0, max = 100]. We showed that ten percent serum supplementation to the extraction medium, as well as longer incubation of the cells with the extract, greatly increased the test sensitivity for PVC. Conclusion The results clearly show that the specifications set by the ISO 10993-5 are not explicit enough to obtain comparable results for an identical medical device. To set requirements that ensure reliable cytotoxicity assessments, further research will be necessary to identify the best test conditions for specific materials and/or devices and the standard needs to be revised accordingly.
Collapse
Affiliation(s)
- Sarah Gruber
- Department of Product Safety, Johner Institut GmbH, Konstanz, Germany
| | - Angela Nickel
- Department of Regulatory Science, Johner Institut GmbH, Konstanz, Germany
| |
Collapse
|
15
|
Dong H, Wen Y, Lin J, Zhuang X, Xian R, Li P, Li S. Cytotoxicity Induced by Black Phosphorus Nanosheets in Vascular Endothelial Cells via Oxidative Stress and Apoptosis Activation. J Funct Biomater 2023; 14:jfb14050284. [PMID: 37233394 DOI: 10.3390/jfb14050284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/25/2023] [Accepted: 05/15/2023] [Indexed: 05/27/2023] Open
Abstract
Black phosphorus (BP), an emerging two-dimensional material with unique optical, thermoelectric, and mechanical properties, has been proposed as bioactive material for tissue engineering. However, its toxic effects on physiological systems remain obscure. The present study investigated the cytotoxicity of BP to vascular endothelial cells. BP nanosheets (BPNSs) with a diameter of 230 nm were fabricated via a classical liquid-phase exfoliation method. Human umbilical vein endothelial cells (HUVECs) were used to determine the cytotoxicity induced by BPNSs (0.31-80 μg/mL). When the concentrations were over 2.5 μg/mL, BPNSs adversely affected the cytoskeleton and cell migration. Furthermore, BPNSs caused mitochondrial dysfunction and generated excessive intercellular reactive oxygen species (ROS) at tested concentrations after 24 h. BPNSs could influence the expression of apoptosis-related genes, including the P53 and BCL-2 family, resulting in the apoptosis of HUVECs. Therefore, the viability and function of HUVECs were adversely influenced by the concentration of BPNSs over 2.5 μg/mL. These findings provide significant information for the potential applications of BP in tissue engineering.
Collapse
Affiliation(s)
- Hao Dong
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Yin Wen
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Jiating Lin
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Xianxian Zhuang
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Ruoting Xian
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Ping Li
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Shaobing Li
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
- First Clinical Medical College, Xinjiang Medical University, Urumqi 830011, China
- The First People's Hospital of Kashgar Region, Kashgar 844000, China
| |
Collapse
|
16
|
Heiss A, Thatikonda VS, Richter A, Schmitt LY, Park D, Klotz UE. Development, Processing and Aging of Novel Zn-Ag-Cu Based Biodegradable Alloys. MATERIALS (BASEL, SWITZERLAND) 2023; 16:3198. [PMID: 37110036 PMCID: PMC10141850 DOI: 10.3390/ma16083198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 04/08/2023] [Accepted: 04/14/2023] [Indexed: 06/19/2023]
Abstract
The use of biodegradable materials for implants is a promising strategy to overcome known long-term clinical complications related to permanent implants. Ideally, biodegradable implants support the damaged tissue for a certain period and then degrade, while the physiological function of the surrounding tissue is restored. Although Mg-based alloys nearly ideally lend themselves to biodegradable implants, a few critical shortcomings promoted the development of alternative alloy systems. Due to their reasonably good biocompatibility, moderate corrosion rate without hydrogen evolution and adequate mechanical properties, increasing attention has been paid to Zn alloys. In this work, precipitation-hardening alloys in the system Zn-Ag-Cu were developed relying on thermodynamic calculations. After casting the alloys, their microstructures were refined by thermomechanical treatment. The processing was tracked and directed, respectively, by routine investigations of the microstructure, associated with hardness assessments. Although microstructure refinement increased the hardness, the material proved to be susceptible to aging as the homologous temperature of zinc is at 0.43 Tm. Besides mechanical performance and corrosion rate, long-term mechanical stability is another crucial factor that must be taken into consideration to ensure the safety of the implant and thus requires a profound understanding of the aging process.
Collapse
Affiliation(s)
- Alexander Heiss
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| | - Venkat Sai Thatikonda
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
- Department of Precision-Optics-Materials-Environment, University of Applied Sciences, 07745 Jena, Germany
| | - Andreas Richter
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| | - Lisa-Yvonn Schmitt
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| | - Daesung Park
- Physikalisch-Technische Bundesanstalt (PTB), 38116 Braunschweig, Germany
- Laboratory of Emerging Nanometrology (LENA), 38106 Braunschweig, Germany
| | - Ulrich E. Klotz
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| |
Collapse
|
17
|
Panaghie C, Zegan G, Sodor A, Cimpoeșu N, Lohan NM, Istrate B, Roman AM, Ioanid N. Analysis of Degradation Products of Biodegradable ZnMgY Alloy. MATERIALS (BASEL, SWITZERLAND) 2023; 16:3092. [PMID: 37109928 PMCID: PMC10146815 DOI: 10.3390/ma16083092] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2023] [Revised: 04/06/2023] [Accepted: 04/12/2023] [Indexed: 06/19/2023]
Abstract
Biodegradable metallic materials are increasingly gaining ground in medical applications. Zn-based alloys show a degradation rate between those recorded for Mg-based materials with the fastest degradation rate and Fe-based materials with the slowest degradation rate. From the perspective of medical complications, it is essential to understand the size and nature of the degradation products developed from biodegradable materials, as well as the stage at which these residues are eliminated from the body. This paper presents investigations conducted on the corrosion/degradation products of an experimental material (ZnMgY alloy in cast and homogenized state) after immersion tests in three physiological solutions (Dulbecco's, Ringer's and simulated body fluid (SBF)). Scanning electron microscopy (SEM) was used to highlight the macroscopic and microscopic aspects of corrosion products and their effects on the surface. An X-ray energy dispersive detector (EDS), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) provided general information about the compounds based on their non-metallic character. The pH of the electrolyte solution was recorded for 72 h during immersion. The pH variation of the solution confirmed the main reactions proposed for the corrosion of ZnMg. The agglomerations of corrosion products were on the micrometer scale, mainly oxides, hydroxides and carbonates or phosphates. The corrosion effects on the surface were homogeneously spread, with a tendency to connect and form cracks or larger corrosion zones, transforming the pitting corrosion pattern into a generalized one. It was noticed that the alloy's microstructure strongly influences the corrosion characteristics.
Collapse
Affiliation(s)
- Cătălin Panaghie
- Faculty of Materials Science and Engineering, “Gh. Asachi” Technical University from Iasi, 700050 Iasi, Romania
| | - Georgeta Zegan
- Faculty of Dental Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Alina Sodor
- Faculty of Dental Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Nicanor Cimpoeșu
- Faculty of Materials Science and Engineering, “Gh. Asachi” Technical University from Iasi, 700050 Iasi, Romania
| | - Nicoleta-Monica Lohan
- Faculty of Materials Science and Engineering, “Gh. Asachi” Technical University from Iasi, 700050 Iasi, Romania
| | - Bogdan Istrate
- Faculty of Mechanics, “Gh. Asachi” Technical University from Iasi, 700050 Iasi, Romania
| | - Ana-Maria Roman
- Faculty of Materials Science and Engineering, “Gh. Asachi” Technical University from Iasi, 700050 Iasi, Romania
| | - Nicoleta Ioanid
- Faculty of Dental Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
| |
Collapse
|
18
|
Liu Q, Li A, Liu S, Fu Q, Xu Y, Dai J, Li P, Xu S. Cytotoxicity of Biodegradable Zinc and Its Alloys: A Systematic Review. J Funct Biomater 2023; 14:206. [PMID: 37103296 PMCID: PMC10144193 DOI: 10.3390/jfb14040206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/18/2023] [Accepted: 03/27/2023] [Indexed: 04/28/2023] Open
Abstract
Zinc-based biodegradable metals (BMs) have been developed for biomedical implant materials. However, the cytotoxicity of Zn and its alloys has caused controversy. This work aims to investigate whether Zn and its alloys possess cytotoxic effects and the corresponding influence factors. According to the guidelines of the PRISMA statement, an electronic combined hand search was conducted to retrieve articles published in PubMed, Web of Science, and Scopus (2013.1-2023.2) following the PICOS strategy. Eighty-six eligible articles were included. The quality of the included toxicity studies was assessed utilizing the ToxRTool. Among the included articles, extract tests were performed in 83 studies, and direct contact tests were conducted in 18 studies. According to the results of this review, the cytotoxicity of Zn-based BMs is mainly determined by three factors, namely, Zn-based materials, tested cells, and test system. Notably, Zn and its alloys did not exhibit cytotoxic effects under certain test conditions, but significant heterogeneity existed in the implementation of the cytotoxicity evaluation. Furthermore, there is currently a relatively lower quality of current cytotoxicity evaluation in Zn-based BMs owing to the adoption of nonuniform standards. Establishing a standardized in vitro toxicity assessment system for Zn-based BMs is required for future investigations.
Collapse
Affiliation(s)
- Qian Liu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - An Li
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Shizhen Liu
- The School of Computing Science, University of Glasgow, Glasgow G12 8RZ, UK
| | - Qingyun Fu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Yichen Xu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Jingtao Dai
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Ping Li
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Shulan Xu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| |
Collapse
|
19
|
Deng S, Zhang Y, Qiao Z, Wang K, Ye L, Xu Y, Hu T, Bai H, Fu Q. Hierarchically Designed Biodegradable Polylactide Particles with Unprecedented Piezocatalytic Activity and Biosafety for Tooth Whitening. Biomacromolecules 2023; 24:797-806. [PMID: 36642871 DOI: 10.1021/acs.biomac.2c01252] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
At-home tooth whitening solutions with good efficacy and biosafety are highly desirable to meet the ever-growing demand for aesthetic dentistry. As a promising alternative to the classic peroxide bleaching that may damage tooth enamel and gums, piezocatalysis has been recently proposed to realize non-destructive whitening by toothbrushing with piezoelectrical particles. However, traditional particles either pose potential threats to human health or exhibit low piezoresponse to weak mechanical stimuli in the toothbrushing. Here, biocompatible and biodegradable polylactide particles constructed from interlocking crystalline lamellae have been hierarchically designed as next-generation whitening materials with ultra-high piezocatalytic activity and biosafety. By simultaneously controlling the chain conformation within lamellae and the porosity of such unique lamellae network at the nano- and microscales, the particles possessing unprecedented piezoelectricity have been successfully prepared due to the markedly increased dipole alignment, mechanical deformability, and specific surface area. The piezoelectric output can reach as high as 18.8 V, nearly 50 times higher than that of common solid polylactide particles. Consequently, their piezocatalytic effect can be readily activated by a toothbrush to rapidly clean the teeth stained with black tea and coffee, without causing detectable enamel damage. Furthermore, these particles have no cytotoxicity. This work presents a paradigm for achieving high piezoelectric activity in polylactide, which enables its practical application in tooth whitening.
Collapse
Affiliation(s)
- Shihao Deng
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu610065, P. R. China
| | - Yue Zhang
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu610041, P. R. China
| | - Zeshuang Qiao
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu610065, P. R. China
| | - Ke Wang
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu610065, P. R. China
| | - Ling Ye
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu610041, P. R. China
| | - Yichen Xu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu610041, P. R. China
| | - Tao Hu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu610041, P. R. China
| | - Hongwei Bai
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu610065, P. R. China
| | - Qiang Fu
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu610065, P. R. China
| |
Collapse
|
20
|
Wątroba M, Bednarczyk W, Szewczyk PK, Kawałko J, Mech K, Grünewald A, Unalan I, Taccardi N, Boelter G, Banzhaf M, Hain C, Bała P, Boccaccini AR. In vitro cytocompatibility and antibacterial studies on biodegradable Zn alloys supplemented by a critical assessment of direct contact cytotoxicity assay. J Biomed Mater Res B Appl Biomater 2023; 111:241-260. [PMID: 36054531 PMCID: PMC10086991 DOI: 10.1002/jbm.b.35147] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 07/11/2022] [Accepted: 07/17/2022] [Indexed: 12/15/2022]
Abstract
In vitro cytotoxicity assessment is indispensable in developing new biodegradable implant materials. Zn, which demonstrates an ideal corrosion rate between Mg- and Fe-based alloys, has been reported to have excellent in vivo biocompatibility. Therefore, modifications aimed at improving Zn's mechanical properties should not degrade its biological response. As sufficient strength, ductility and corrosion behavior required of load-bearing implants has been obtained in plastically deformed Zn-3Ag-0.5Mg, the effect of simultaneous Ag and Mg additions on in vitro cytocompatibility and antibacterial properties was studied, in relation to Zn and Zn-3Ag. Direct cell culture on samples and indirect extract-based tests showed almost no significant differences between the tested Zn-based materials. The diluted extracts of Zn, Zn-3Ag, and Zn-3Ag-0.5Mg showed no cytotoxicity toward MG-63 cells at a concentration of ≤12.5%. The cytotoxic effect was observed only at high Zn2+ ion concentrations and when in direct contact with metallic samples. The highest LD50 (lethal dose killing 50% of cells) of 13.4 mg/L of Zn2+ ions were determined for the Zn-3Ag-0.5Mg. Similar antibacterial activity against Escherichia coli and Staphylococcus aureus was observed for Zn and Zn alloys, so the effect is attributed mainly to the released Zn2+ ions exhibiting bactericidal properties. Most importantly, our experiments indicated the limitations of water-soluble tetrazolium salt-based cytotoxicity assays for direct tests on Zn-based materials. The discrepancies between the WST-8 assay and SEM observations are attributed to the interference of Zn2+ ions with tetrazolium salt, therefore favoring its transformation into formazan, giving false cell viability quantitative results.
Collapse
Affiliation(s)
- Maria Wątroba
- Laboratory for Mechanics of Materials and Nanostructures, Empa, Swiss Federal Laboratories for Materials Science and Technology, Thun, Switzerland.,Faculty of Metals Engineering and Industrial Computer Science, AGH University of Science and Technology, Krakow, Poland
| | - Wiktor Bednarczyk
- Faculty of Materials Science and Engineering, Warsaw University of Technology, Warsaw, Poland
| | - Piotr K Szewczyk
- Faculty of Metals Engineering and Industrial Computer Science, AGH University of Science and Technology, Krakow, Poland
| | - Jakub Kawałko
- Academic Centre for Materials and Nanotechnology, AGH University of Science and Technology, Krakow, Poland
| | - Krzysztof Mech
- Academic Centre for Materials and Nanotechnology, AGH University of Science and Technology, Krakow, Poland
| | - Alina Grünewald
- Department of Materials Science and Engineering, Institute of Biomaterials, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Irem Unalan
- Department of Materials Science and Engineering, Institute of Biomaterials, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Nicola Taccardi
- Institute of Chemical Reaction Engineering, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Gabriela Boelter
- Institute of Microbiology and Infection and School of Biosciences, University of Birmingham, Birmingham, UK
| | - Manuel Banzhaf
- Institute of Microbiology and Infection and School of Biosciences, University of Birmingham, Birmingham, UK
| | - Caroline Hain
- Laboratory for Mechanics of Materials and Nanostructures, Empa, Swiss Federal Laboratories for Materials Science and Technology, Thun, Switzerland.,Institute for Applied Laser Photonics and Surface Technologies ALPS, Bern University of Applied Sciences, Biel/Bienne, Switzerland
| | - Piotr Bała
- Faculty of Metals Engineering and Industrial Computer Science, AGH University of Science and Technology, Krakow, Poland.,Academic Centre for Materials and Nanotechnology, AGH University of Science and Technology, Krakow, Poland
| | - Aldo R Boccaccini
- Department of Materials Science and Engineering, Institute of Biomaterials, University of Erlangen-Nuremberg, Erlangen, Germany
| |
Collapse
|
21
|
Lambart AL, Xepapadeas AB, Koos B, Li P, Spintzyk S. Rinsing postprocessing procedure of a 3D-printed orthodontic appliance material: Impact of alternative post-rinsing solutions on the roughness, flexural strength and cytotoxicity. Dent Mater 2022; 38:1344-1353. [PMID: 35752470 DOI: 10.1016/j.dental.2022.06.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 05/04/2022] [Accepted: 06/05/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVE The present study evaluated the effect of different rinsing postprocessing solutions on surface characteristics, flexural strength, and cytotoxicity of an additive manufactured polymer for orthodontic appliances. These solutions have been deemed an alternative to the standard isopropanol which is a flammable liquid, known to have toxic effects. METHODS Tested specimens were manufactured using direct light processing of an orthodontic appliance polymer (FREEPRINT® splint 2.0, Detax) and post-processed with different post-rinsing solutions, including isopropanol (IPA), ethanol (EtOH), EASY 3D Cleaner (EYC), Yellow Magic7 (YM7), and RESINAWAY (RAY), respectively. All groups were post-cured following the manufacturer's instructions. Surface topography and roughness (Ra and Rv) were evaluated. In addition, flexural strength was measured by a three-point bending test. An extract test was performed to evaluate cytotoxicity. The data were analyzed by the Kruskal-Wallis test with Dunn's multiple comparisons test (p < 0.05). RESULTS Various post-rinsing solutions did not significantly affect the roughness values (Ra and Rv). Specimens post-processed with EtOH (98.1 ± 12.4 MPa) and EYC (101.1 ± 6.3 MPa) exhibited significantly lower flexural strength compared to the groups of IPA (110.7 ± 5.3 MPa), RAY (112.1 ± 5.6 MPa) and YM7 (117.3 ± 5.9 MPa), respectively. Finally, there were no cytotoxic effects of parts cleaned with different post-rinsing solutions. SIGNIFICANCE Considering the use of 3D-printed orthodontic appliance materials, different rinsing postprocessing procedures did not affect surface characteristics. However, the flexural strength was significantly influenced, which could be attributed to the chemical ingredients of the post-rinsing solutions. Various post-rinsing treatments had no alternation concerning cytocompatibility.
Collapse
Affiliation(s)
- Anna-Lena Lambart
- Department of Orthodontics, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany; Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Alexander B Xepapadeas
- Department of Orthodontics, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Bernd Koos
- Department of Orthodontics, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Ping Li
- Center of Oral Implantology, Stomatological Hospital, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China; Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany.
| | - Sebastian Spintzyk
- Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany; ADMiRE Lab - Additive Manufacturing, intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, Europastraße 4, 9524 Villach, Austria
| |
Collapse
|
22
|
Hsiao YP, Mukundan A, Chen WC, Wu MT, Hsieh SC, Wang HC. Design of a Lab-On-Chip for Cancer Cell Detection through Impedance and Photoelectrochemical Response Analysis. BIOSENSORS 2022; 12:bios12060405. [PMID: 35735553 PMCID: PMC9221223 DOI: 10.3390/bios12060405] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 06/09/2022] [Accepted: 06/09/2022] [Indexed: 05/07/2023]
Abstract
In this study, a biochip was fabricated using a light-absorbing layer of a silicon solar element combined with serrated, interdigitated electrodes and used to identify four different types of cancer cells: CE81T esophageal cancer, OE21 esophageal cancer, A549 lung adenocarcinoma, and TSGH-8301 bladder cancer cells. A string of pearls was formed from dielectrophoretic aggregated cancer cells because of the serrated interdigitated electrodes. Thus, cancer cells were identified in different parts, and electron-hole pairs were separated by photo-excited carriers through the light-absorbing layer of the solar element. The concentration catalysis mechanism of GSH and GSSG was used to conduct photocurrent response and identification, which provides the fast, label-free measurement of cancer cells. The total time taken for this analysis was 13 min. Changes in the impedance value and photocurrent response of each cancer cell were linearly related to the number of cells, and the slope of the admittance value was used to distinguish the location of the cancerous lesion, the slope of the photocurrent response, and the severity of the cancerous lesion. The results show that the number of cancerous cells was directly proportional to the admittance value and the photocurrent response for all four different types of cancer cells. Additionally, different types of cancer cells could easily be differentiated using the slope value of the photocurrent response and the admittance value.
Collapse
Affiliation(s)
- Yu-Ping Hsiao
- Department of Dermatology, Chung Shan Medical University Hospital, No.110, Sec. 1, Jianguo N. Rd., South District, Taichung City 40201, Taiwan;
- Institute of Medicine, School of Medicine, Chung Shan Medical University, No.110, Sec. 1, Jianguo N. Rd., South District, Taichung City 40201, Taiwan
| | - Arvind Mukundan
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High Tech Innovations (AIM-HI), Center for Innovative Research on Aging Society (CIRAS), National Chung Cheng University, 168, University Rd., Min Hsiung, Chia Yi 62102, Taiwan;
| | - Wei-Chung Chen
- Ph.D. Program in Environmental and Occupational Medicine, Kaohsiung Medical University, Kaohsiung 807377, Taiwan; (W.-C.C.); (M.-T.W.)
| | - Ming-Tsang Wu
- Ph.D. Program in Environmental and Occupational Medicine, Kaohsiung Medical University, Kaohsiung 807377, Taiwan; (W.-C.C.); (M.-T.W.)
- Research Center for Environmental Medicine, Kaohsiung Medical University, Kaohsiung 807377, Taiwan
- Department of Public Health, Kaohsiung Medical University, Kaohsiung 807377, Taiwan
- Department of Family Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung 807377, Taiwan
| | - Shang-Chin Hsieh
- Department of Plastic Surgery, Kaohsiung Armed Forces General Hospital, 2, Zhongzheng 1st Rd., Lingya District, Kaohsiung 80284, Taiwan
- Correspondence: (S.-C.H.); (H.-C.W.)
| | - Hsiang-Chen Wang
- Department of Mechanical Engineering, Advanced Institute of Manufacturing with High Tech Innovations (AIM-HI), Center for Innovative Research on Aging Society (CIRAS), National Chung Cheng University, 168, University Rd., Min Hsiung, Chia Yi 62102, Taiwan;
- Correspondence: (S.-C.H.); (H.-C.W.)
| |
Collapse
|
23
|
Xu Y, Xu Y, Zhang W, Li M, Wendel HP, Geis-Gerstorfer J, Li P, Wan G, Xu S, Hu T. Biodegradable Zn-Cu-Fe Alloy as a Promising Material for Craniomaxillofacial Implants: An in vitro Investigation into Degradation Behavior, Cytotoxicity, and Hemocompatibility. Front Chem 2022; 10:860040. [PMID: 35734444 PMCID: PMC9208203 DOI: 10.3389/fchem.2022.860040] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 05/19/2022] [Indexed: 11/13/2022] Open
Abstract
Zinc-based nanoparticles, nanoscale metal frameworks and metals have been considered as biocompatible materials for bone tissue engineering. Among them, zinc-based metals are recognized as promising biodegradable materials thanks to their moderate degradation rate ranging between magnesium and iron. Nonetheless, materials’ biodegradability and the related biological response depend on the specific implant site. The present study evaluated the biodegradability, cytocompatibility, and hemocompatibility of a hot-extruded zinc-copper-iron (Zn-Cu-Fe) alloy as a potential biomaterial for craniomaxillofacial implants. Firstly, the effect of fetal bovine serum (FBS) on in vitro degradation behavior was evaluated. Furthermore, an extract test was used to evaluate the cytotoxicity of the alloy. Also, the hemocompatibility evaluation was carried out by a modified Chandler-Loop model. The results showed decreased degradation rates of the Zn-Cu-Fe alloy after incorporating FBS into the medium. Also, the alloy exhibited acceptable toxicity towards RAW264.7, HUVEC, and MC3T3-E1 cells. Regarding hemocompatibility, the alloy did not significantly alter erythrocyte, platelet, and leukocyte counts, while the coagulation and complement systems were activated. This study demonstrated the predictable in vitro degradation behavior, acceptable cytotoxicity, and appropriate hemocompatibility of Zn-Cu-Fe alloy; therefore, it might be a candidate biomaterial for craniomaxillofacial implants.
Collapse
Affiliation(s)
- Yan Xu
- Center of Oral Implantology, Stomatological Hospital, Southern Medical University, Guangzhou, China
| | - Yichen Xu
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
- Section Medical Materials Science and Technology, University Hospital Tübingen, Tübingen, Germany
| | - Wentai Zhang
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, China
| | - Ming Li
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, China
- Department of Materials Engineering, Sichuan Engineering Technical College, Deyang, China
| | - Hans-Peter Wendel
- Department of Thoracic and Cardiovascular Surgery, Clinical Research Laboratory, University Hospital Tübingen, Tübingen, Germany
| | - Jürgen Geis-Gerstorfer
- Section Medical Materials Science and Technology, University Hospital Tübingen, Tübingen, Germany
| | - Ping Li
- Center of Oral Implantology, Stomatological Hospital, Southern Medical University, Guangzhou, China
- Section Medical Materials Science and Technology, University Hospital Tübingen, Tübingen, Germany
- *Correspondence: Ping Li, ; Guojiang Wan, ; Shulan Xu,
| | - Guojiang Wan
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, China
- *Correspondence: Ping Li, ; Guojiang Wan, ; Shulan Xu,
| | - Shulan Xu
- Center of Oral Implantology, Stomatological Hospital, Southern Medical University, Guangzhou, China
- *Correspondence: Ping Li, ; Guojiang Wan, ; Shulan Xu,
| | - Tao Hu
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, Department of Preventive Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| |
Collapse
|
24
|
Chen J, Dai J, Qian J, Li W, Li R, Pang D, Wan G, Li P, Xu S. Influence of Surface Roughness on Biodegradability and Cytocompatibility of High-Purity Magnesium. MATERIALS 2022; 15:ma15113991. [PMID: 35683285 PMCID: PMC9182346 DOI: 10.3390/ma15113991] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 05/25/2022] [Accepted: 05/29/2022] [Indexed: 11/16/2022]
Abstract
High-purity magnesium (Mg) is a promising biodegradable metal for oral and maxillofacial implants. Appropriate surface roughness plays a critical role in the degradation behavior and the related cellular processes of biodegradable Mg-based metals. Nevertheless, the most optimized surface roughness has been questionable, especially for Mg-based oral and maxillofacial implants. Three representative scales of surface roughness were investigated in this study, including smooth (Sa < 0.5 µm), moderately rough (Sa between 1.0−2.0 µm), and rough (Sa > 2.0 µm). The results indicated that the degradation rate of the Mg specimen in the cell culture medium was significantly accelerated with increased surface roughness. Furthermore, an extract test revealed that Mg with different roughness did not induce an evident cytotoxic effect. Nonetheless, the smooth Mg surface had an adversely affected cell attachment. Therefore, the high-purity Mg with a moderately rough surface exhibited the most optimized balance between biodegradability and overall cytocompatibility.
Collapse
Affiliation(s)
- Jiahao Chen
- Department of Oral Implantology, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China; (J.C.); (J.D.)
| | - Jingtao Dai
- Department of Oral Implantology, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China; (J.C.); (J.D.)
| | - Junyu Qian
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China; (J.Q.); (G.W.)
| | - Weirong Li
- Medical Device Division, Dongguan Eontec Co., Ltd., Dongguan 523662, China; (W.L.); (R.L.); (D.P.)
| | - Ronghui Li
- Medical Device Division, Dongguan Eontec Co., Ltd., Dongguan 523662, China; (W.L.); (R.L.); (D.P.)
| | - Dong Pang
- Medical Device Division, Dongguan Eontec Co., Ltd., Dongguan 523662, China; (W.L.); (R.L.); (D.P.)
| | - Guojiang Wan
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China; (J.Q.); (G.W.)
| | - Ping Li
- Department of Oral Implantology, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China; (J.C.); (J.D.)
- Correspondence: (P.L.); (S.X.)
| | - Shulan Xu
- Department of Oral Implantology, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China; (J.C.); (J.D.)
- Correspondence: (P.L.); (S.X.)
| |
Collapse
|
25
|
Huang X, Lv ZT, Cheng P, Chen AM. A Novel Low Air Pressure-Assisted Approach for the Construction of Cells-Decellularized Tendon Scaffold Complex. Curr Med Sci 2022; 42:569-576. [DOI: 10.1007/s11596-022-2603-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 05/09/2022] [Indexed: 11/03/2022]
|
26
|
Xiang E, Gómez-Cerezo MN, Ali Y, Ramachandra SS, Yang N, Dargusch M, Moran CS, Ivanovski S, Abdal-Hay A. Surface Modification of Pure Zinc by Acid Etching: Accelerating the Corrosion Rate and Enhancing Biocompatibility and Antibacterial Characteristics. ACS APPLIED MATERIALS & INTERFACES 2022; 14:22554-22569. [PMID: 35533291 DOI: 10.1021/acsami.2c00918] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Zinc (Zn) has recently been identified as an auspicious biodegradable metal for medical implants and devices due to its tunable mechanical properties and good biocompatibility. However, the slow corrosion rate of Zn in a physiological environment does not meet the requirements for biodegradable implants, hindering its clinical translation. The present study aimed to accelerate the corrosion rate of pure Zn by utilizing acid etching to roughen the surface and increase the substrate surface area. The effects of acid etching on surface morphology, surface roughness, tensile properties, hardness, electrochemical corrosion and degradation behavior, cytocompatibility, direct cell attachment, and biofilm formation were investigated. Interestingly, acid-treated Zn showed an exceptionally high rate of corrosion (∼226-125 μm/year) compared to untreated Zn (∼62 μm/year), attributed to the increased surface roughness (Ra ∼ 1.12 μm) of acid-etched samples. Immersion tests in Hank's solution revealed that acid etching accelerated the degradation rate of Zn samples. In vitro, MC3T3-E1 cell lines in 50 and 25% conditioned media extracts of treated samples showed good cytocompatibility. Reduced bacterial adhesion, biofilm formation, and dispersion were observed for Staphylococci aureus biofilms cultured on acid-etched pure Zn substrates. These results suggest that the surface modification of biodegradable pure Zn metals by acid etching markedly increases the translation potential of zinc for various biomedical applications.
Collapse
Affiliation(s)
- Enmao Xiang
- The University of Queensland, School of Dentistry, Herston, Queensland 4006, Australia
| | | | - Yahia Ali
- School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, Queensland 4072, Australia
| | | | - Nan Yang
- School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Matthew Dargusch
- School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, Queensland 4072, Australia
| | - Corey S Moran
- The University of Queensland, School of Dentistry, Herston, Queensland 4006, Australia
| | - Saso Ivanovski
- The University of Queensland, School of Dentistry, Herston, Queensland 4006, Australia
| | - Abdalla Abdal-Hay
- The University of Queensland, School of Dentistry, Herston, Queensland 4006, Australia
- Department of Engineering Materials and Mechanical Design, Faculty of Engineering, South Valley University, Qena 85325, Egypt
| |
Collapse
|
27
|
Balancing the biocompatibility and bacterial resistance of polypyrrole by optimized silver incorporation. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2022; 134:112701. [DOI: 10.1016/j.msec.2022.112701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 01/21/2022] [Accepted: 02/04/2022] [Indexed: 11/19/2022]
|
28
|
Francisco I, Paula AB, Ribeiro M, Marques F, Travassos R, Nunes C, Pereira F, Marto CM, Carrilho E, Vale F. The Biological Effects of 3D Resins Used in Orthodontics: A Systematic Review. Bioengineering (Basel) 2022; 9:bioengineering9010015. [PMID: 35049724 PMCID: PMC8773237 DOI: 10.3390/bioengineering9010015] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 12/27/2021] [Accepted: 12/30/2021] [Indexed: 11/16/2022] Open
Abstract
Three-dimensional (3D) resin medical-dental devices have been increasingly used in recent years after the emergence of digital technologies. In Orthodontics, therapies with aligners have gained popularity, mainly due to the aggressive promotion policies developed by the industry. However, their systemic effects are largely unknown, with few studies evaluating the systemic toxicity of these materials. The release of bisphenol A and other residual monomers have cytotoxic, genotoxic, and estrogenic effects. This systematic review aims to analyze the release of toxic substances from 3D resins used in Orthodontics and their toxic systemic effects systematically. The PICO question asked was, "Does the use of 3D resins in orthodontic devices induce cytotoxic effects or changes in estrogen levels?". The search was carried out in several databases and according to PRISMA guidelines. In vitro, in vivo, and clinical studies were included. The in vitro studies' risk of bias was assessed using the guidelines for the reporting of pre-clinical studies on dental materials by Faggion Jr. For the in vivo studies, the SYRCLE risk of bias tool was used, and for the clinical studies, the Cochrane tool. A total of 400 articles retrieved from the databases were initially scrutinized. Fourteen articles were included for qualitative analysis. The risk of bias was considered medium to high. Cytotoxic effects or estrogen levels cannot be confirmed based on the limited preliminary evidence given by in vitro studies. Evidence of the release of bisphenol A and other monomers from 3D resin devices, either in vitro or clinical studies, remains ambiguous. The few robust results in the current literature demonstrate the absolute need for further studies, especially given the possible implications for the young patient's fertility, which constitutes one of the largest groups of patients using these orthodontic devices.
Collapse
Affiliation(s)
- Inês Francisco
- Faculty of Medicine, Institute of Orthodontics, University of Coimbra, 3004-531 Coimbra, Portugal; (A.B.P.); (M.R.); (F.M.); (R.T.); (C.N.); (F.P.); (F.V.)
- Correspondence:
| | - Anabela Baptista Paula
- Faculty of Medicine, Institute of Orthodontics, University of Coimbra, 3004-531 Coimbra, Portugal; (A.B.P.); (M.R.); (F.M.); (R.T.); (C.N.); (F.P.); (F.V.)
- Faculty of Medicine, Institute of Integrated Clinical Practice, University of Coimbra, 3004-531 Coimbra, Portugal; (C.M.M.); (E.C.)
- Faculty of Medicine, Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra Institute for Clinical and Biomedical Research (iCBR), University of Coimbra, 3004-531 Coimbra, Portugal
- Centre for Innovative Biomedicine and Biotechnology (CIBB), University of Coimbra, 3004-531 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3004-531 Coimbra, Portugal
| | - Madalena Ribeiro
- Faculty of Medicine, Institute of Orthodontics, University of Coimbra, 3004-531 Coimbra, Portugal; (A.B.P.); (M.R.); (F.M.); (R.T.); (C.N.); (F.P.); (F.V.)
| | - Filipa Marques
- Faculty of Medicine, Institute of Orthodontics, University of Coimbra, 3004-531 Coimbra, Portugal; (A.B.P.); (M.R.); (F.M.); (R.T.); (C.N.); (F.P.); (F.V.)
| | - Raquel Travassos
- Faculty of Medicine, Institute of Orthodontics, University of Coimbra, 3004-531 Coimbra, Portugal; (A.B.P.); (M.R.); (F.M.); (R.T.); (C.N.); (F.P.); (F.V.)
| | - Catarina Nunes
- Faculty of Medicine, Institute of Orthodontics, University of Coimbra, 3004-531 Coimbra, Portugal; (A.B.P.); (M.R.); (F.M.); (R.T.); (C.N.); (F.P.); (F.V.)
| | - Flávia Pereira
- Faculty of Medicine, Institute of Orthodontics, University of Coimbra, 3004-531 Coimbra, Portugal; (A.B.P.); (M.R.); (F.M.); (R.T.); (C.N.); (F.P.); (F.V.)
| | - Carlos Miguel Marto
- Faculty of Medicine, Institute of Integrated Clinical Practice, University of Coimbra, 3004-531 Coimbra, Portugal; (C.M.M.); (E.C.)
- Faculty of Medicine, Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra Institute for Clinical and Biomedical Research (iCBR), University of Coimbra, 3004-531 Coimbra, Portugal
- Centre for Innovative Biomedicine and Biotechnology (CIBB), University of Coimbra, 3004-531 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3004-531 Coimbra, Portugal
- Faculty of Medicine, Institute of Experimental Pathology, University of Coimbra, 3004-531 Coimbra, Portugal
| | - Eunice Carrilho
- Faculty of Medicine, Institute of Integrated Clinical Practice, University of Coimbra, 3004-531 Coimbra, Portugal; (C.M.M.); (E.C.)
- Faculty of Medicine, Area of Environment Genetics and Oncobiology (CIMAGO), Coimbra Institute for Clinical and Biomedical Research (iCBR), University of Coimbra, 3004-531 Coimbra, Portugal
- Centre for Innovative Biomedicine and Biotechnology (CIBB), University of Coimbra, 3004-531 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3004-531 Coimbra, Portugal
| | - Francisco Vale
- Faculty of Medicine, Institute of Orthodontics, University of Coimbra, 3004-531 Coimbra, Portugal; (A.B.P.); (M.R.); (F.M.); (R.T.); (C.N.); (F.P.); (F.V.)
| |
Collapse
|
29
|
Xiao X, Liu E, Shao J, Ge S. Advances on biodegradable zinc-silver-based alloys for biomedical applications. J Appl Biomater Funct Mater 2021; 19:22808000211062407. [PMID: 34903075 DOI: 10.1177/22808000211062407] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
The biodegradable metals have great potential for the biomedical applications, which could be gradually degraded, absorbed, or excreted in the human body, avoiding the removal though secondary surgery. Zinc-based alloys are novel series of degradable metals for medical applications, and they are gaining lots of attention in the research field of absorbable metals. Zinc-silver (Zn-Ag) alloys show superior mechanical strength, good biodegradability, biocompatibility, and antibacterial properties, which render them to be potential candidates for biomedical applications. In this paper, we reviewed the development of Zn-Ag alloys in terms of mechanical properties, degradabilities, biocompatibilities, antibacterial properties, and potential applications in dentistry.
Collapse
Affiliation(s)
- Ximei Xiao
- Department of Periodontology, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration, Jinan, Shandong, China.,Department of Endodontics, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Enyang Liu
- School of Materials Science and Engineering, China University of Petroleum (East China), Qingdao, China
| | - Jinlong Shao
- Department of Periodontology, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration, Jinan, Shandong, China
| | - Shaohua Ge
- Department of Periodontology, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration, Jinan, Shandong, China
| |
Collapse
|
30
|
García-Mintegui C, Córdoba LC, Buxadera-Palomero J, Marquina A, Jiménez-Piqué E, Ginebra MP, Cortina JL, Pegueroles M. Zn-Mg and Zn-Cu alloys for stenting applications: From nanoscale mechanical characterization to in vitro degradation and biocompatibility. Bioact Mater 2021; 6:4430-4446. [PMID: 34027233 PMCID: PMC8121665 DOI: 10.1016/j.bioactmat.2021.04.015] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 04/09/2021] [Accepted: 04/13/2021] [Indexed: 12/30/2022] Open
Abstract
In the recent decades, zinc (Zn) and its alloys have been drawing attention as promising candidates for bioresorbable cardiovascular stents due to its degradation rate more suitable than magnesium (Mg) and iron (Fe) alloys. However, its mechanical properties need to be improved in order to meet the criteria for vascular stents. This work investigates the mechanical properties, biodegradability and biocompatibility of Zn-Mg and Zn-Cu alloys in order to determine a proper alloy composition for optimal stent performance. Nanoindentation measurements are performed to characterize the mechanical properties at the nanoscale as a function of the Zn microstructure variations induced by alloying. The biodegradation mechanisms are discussed and correlated to microstructure, mechanical performance and bacterial/cell response. Addition of Mg or Cu alloying elements refined the microstructure of Zn and enhanced yield strength (YS) and ultimate tensile strength (UTS) proportional to the volume fraction of secondary phases. Zn-1Mg showed the higher YS and UTS and better performance in terms of degradation stability in Hanks' solution. Zn-Cu alloys presented an antibacterial effect for S. aureus controlled by diffusion mechanisms and by contact. Biocompatibility was dependent on the degradation rate and the nature of the corrosion products.
Collapse
Affiliation(s)
- Claudia García-Mintegui
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Engineering, Technical University of Catalonia (UPC), Barcelona East School of Engineering (EEBE), 08019, Barcelona, Spain
- Resource Recovery and Environmental Management Group, UPC, EEBE, 08019, Barcelona, Spain
- Barcelona Research Center in Multiscale Science and Engineering, UPC, EEBE, 08019, Barcelona, Spain
| | - Laura Catalina Córdoba
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Engineering, Technical University of Catalonia (UPC), Barcelona East School of Engineering (EEBE), 08019, Barcelona, Spain
- Institute for Bioengineering of Catalonia (IBEC), 08028, Barcelona, Spain
| | - Judit Buxadera-Palomero
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Engineering, Technical University of Catalonia (UPC), Barcelona East School of Engineering (EEBE), 08019, Barcelona, Spain
- Barcelona Research Center in Multiscale Science and Engineering, UPC, EEBE, 08019, Barcelona, Spain
| | - Andrea Marquina
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Engineering, Technical University of Catalonia (UPC), Barcelona East School of Engineering (EEBE), 08019, Barcelona, Spain
| | - Emilio Jiménez-Piqué
- Barcelona Research Center in Multiscale Science and Engineering, UPC, EEBE, 08019, Barcelona, Spain
- Structural Integrity, Micromechanics and Reliability of Materials Group, Department of Materials Science and Engineering, UPC, EEBE, 08019, Barcelona, Spain
| | - Maria-Pau Ginebra
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Engineering, Technical University of Catalonia (UPC), Barcelona East School of Engineering (EEBE), 08019, Barcelona, Spain
- Barcelona Research Center in Multiscale Science and Engineering, UPC, EEBE, 08019, Barcelona, Spain
- Institute for Bioengineering of Catalonia (IBEC), 08028, Barcelona, Spain
| | - José Luis Cortina
- Resource Recovery and Environmental Management Group, UPC, EEBE, 08019, Barcelona, Spain
- Barcelona Research Center in Multiscale Science and Engineering, UPC, EEBE, 08019, Barcelona, Spain
| | - Marta Pegueroles
- Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Engineering, Technical University of Catalonia (UPC), Barcelona East School of Engineering (EEBE), 08019, Barcelona, Spain
- Barcelona Research Center in Multiscale Science and Engineering, UPC, EEBE, 08019, Barcelona, Spain
| |
Collapse
|
31
|
Li P, Zhang W, Spintzyk S, Schweizer E, Krajewski S, Alexander D, Dai J, Xu S, Wan G, Rupp F. Impact of sterilization treatments on biodegradability and cytocompatibility of zinc-based implant materials. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 130:112430. [PMID: 34702515 DOI: 10.1016/j.msec.2021.112430] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 08/29/2021] [Accepted: 09/06/2021] [Indexed: 11/18/2022]
Abstract
Biodegradable zinc (Zn) and Zn-based alloys have been recognized as promising biomaterials for biomedical implants. Sterilization is an essential step in handling Zn-based implants before their use in clinical practice and there are various sterilization methods are available. However, how these treatments influence the Zn-based biomaterials remains unknown and is of critical relevance. In this study, three commonly-applied standard sterilization methods, namely gamma irradiation, hydrogen peroxide gas plasma and steam autoclave, were used on pure Zn and Zn3Cu (wt%) alloy. The treated Zn and ZnCu alloy were investigated to compare the different influences of sterilizations on surface characteristics, transient and long-term degradation behavior and cytotoxicity of Zn and Zn alloy. Our results indicate that autoclaving brought about apparently a formation of inhomogeneous zinc oxide film whereas the other two methods produced no apparent alterations on the material surfaces. Consequently, the samples after autoclaving showed significantly faster degradation rates and more severe localized corrosion, especially for the ZnCu alloy, owing to the incomplete covering and unstable zinc oxide layer. Moreover, the autoclave-treated Zn and ZnCu alloy exhibited apparent cytotoxic effects towards fibroblasts, which may be due to the excessive Zn ion releasing and its local concentration exceeds the cellular tolerance capacity. In contrast, gamma irradiation and hydrogen peroxide gas plasma had no apparent adverse effects on the biodegradability and cytocompatibility of Zn and ZnCu alloy. Our findings may have significant implications regarding the selection of suitable sterilization methods for Zn-based implant materials among others.
Collapse
Affiliation(s)
- Ping Li
- Center of Oral Implantology, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China; Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Wentai Zhang
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Sebastian Spintzyk
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Ernst Schweizer
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Stefanie Krajewski
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Dorothea Alexander
- Department of Oral and Maxillofacial Surgery, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Jingtao Dai
- Center of Oral Implantology, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China; Department of Oral and Maxillofacial Surgery, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany.
| | - Shulan Xu
- Center of Oral Implantology, Stomatological Hospital, Southern Medical University, Guangzhou 510280, China.
| | - Guojiang Wan
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
| | - Frank Rupp
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| |
Collapse
|
32
|
Postpolymerization of a 3D-printed denture base polymer: Impact of post-curing methods on surface characteristics, flexural strength, and cytotoxicity. J Dent 2021; 115:103856. [PMID: 34695506 DOI: 10.1016/j.jdent.2021.103856] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 09/30/2021] [Accepted: 10/20/2021] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE This study investigated the influence of postpolymerization of a three-dimensional (3D) printed denture base polymer. The effect of post-curing methods on surface characteristics, flexural strength, and cytotoxicity was evaluated. METHODS A total of 172 specimens were additively manufactured using one denture base material (V-Print dentbase, VOCO) and further post-cured by different light-curing devices, including Otoflash G171 (OF), Labolight DUO (LL), PCU LED (PCU), and LC-3DPrintbox (PB), respectively. Polymethyl methacrylate resin (PalaExpress Ultra) was used as a reference (REF). Afterward, surface topography was observed using scanning electron microscopy, and surface roughness was measured (n = 6). Furthermore, flexural strength was tested (n = 20). Cytotoxicity was evaluated by the extract and direct contact tests. The data were analyzed using the Kolmogorov-Smirnov test and one-way ANOVA followed by Tukey's multiple comparisons and Kruskal-Wallis tests (p < 0.05). RESULTS The different post-curing methods applied did not significantly influence surface topography and roughness (Ra). Meanwhile, specimens post-cured by PCU (162.3 ± 44.16 MPa) and PB (171.2 ± 34.41 MPa) showed significantly higher flexural strength than those post-cured by OF (131.3 ± 32.87 MPa) and REF (131.2 ± 19.19 MPa), respectively. Additionally, various post-curing methods effectively decreased the cytotoxic effects of 3D-printed denture base polymer. CONCLUSIONS Different post-curing methods did not significantly alter the Ra values of the 3D-printed denture base material. However, flexural strength was significantly affected by the postpolymerization methods, which might be attributed to the different wavelengths of post-curing devices. In addition, various postpolymerization methods reduced the cytotoxic effects of the 3D-printed denture base polymer. CLINICAL SIGNIFICANCE Flexural strength of additively manufactured denture bases depends on the postpolymerization strategy. Therefore, an appropriate post-curing method is required to optimize the flexural strength of 3D-printed denture materials.
Collapse
|
33
|
Limitation of Water-Soluble Tetrazolium Salt for the Cytocompatibility Evaluation of Zinc-Based Metals. MATERIALS 2021; 14:ma14216247. [PMID: 34771776 PMCID: PMC8584906 DOI: 10.3390/ma14216247] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 10/11/2021] [Accepted: 10/13/2021] [Indexed: 01/09/2023]
Abstract
Zinc (Zn) and its alloys have been regarded as promising biodegradable metals. The standardized cytotoxicity evaluation is a mandatory step to screen the biocompatibility of novel Zn and its alloys. Nevertheless, the suitability of the tetrazolium-based assay in the direct contact test for some metallic biomaterials (i.e., magnesium and manganese) is questionable. In this study, our results demonstrate an obvious inconsistency between qualitative observation via fluorescence staining and quantitative assessment using water-soluble tetrazolium salt (CCK-8). Subsequent experiments revealed that Zn and pre-treated Zn can directly convert tetrazolium salts to formazan, falsifying the cytotoxicity results. Therefore, we conclude that the CCK-8 assay is not suitable for evaluating the cytotoxicity of biodegradable Zn-based metals in the direct contact test.
Collapse
|
34
|
Test conditions can significantly affect the results of in vitro cytotoxicity testing of degradable metallic biomaterials. Sci Rep 2021; 11:6628. [PMID: 33758226 PMCID: PMC7987994 DOI: 10.1038/s41598-021-85019-6] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 02/12/2021] [Indexed: 12/23/2022] Open
Abstract
In vitro cytotoxicity testing is an indispensable part of the development of new biomaterials. However, the standard ISO 10993-5 enables variability in the testing conditions, which makes the results of the test incomparable. We studied the influence of media composition on the results of the cytotoxicity test. Solutions of ZnCl2 served as simulated extracts and we also used extracts of three types of Zn-based and Mg-based degradable metals. We incubated the cells with the solutions prepared in two types of media with two concentrations of serum (5 and 10%). We compared the toxic effect of the extracts on L929 murine fibroblast-derived cell line, which is recommended by ISO standard and on “osteoblast-like cells” U-2 OS. We also compared two methods of exposition: solutions were added either to a sub-confluent layer or to the cell suspension. We evaluated the metabolic activity of the cells using the resazurin test. We found out that in vitro cytotoxicity is dramatically influenced by the concentration of serum and by the type of the medium as well as by the type of exposition and type of cells. Therefore, when performing in vitro cytotoxicity testing of biomaterials, the authors should carefully specify the conditions of the test and comparison of different studies should be carried out with caution.
Collapse
|
35
|
Wątroba M, Bednarczyk W, Kawałko J, Bała P. Fine-tuning of mechanical properties in a Zn-Ag-Mg alloy via cold plastic deformation process and post-deformation annealing. Bioact Mater 2021; 6:3424-3436. [PMID: 33817418 PMCID: PMC7988494 DOI: 10.1016/j.bioactmat.2021.03.017] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 02/20/2021] [Accepted: 03/04/2021] [Indexed: 11/29/2022] Open
Abstract
In recent years, Zn-based materials have been extensively investigated as potential candidates for biodegradable implant applications. The introduction of alloying elements providing solid-solution strengthening and second phase strengthening seems crucial to provide a suitable platform for the thermo-mechanical strengthening of Zn alloys. In this study, a systematic investigation of the microstructure, crystallographic texture, phase composition, and mechanical properties of a Zn-3Ag-0.5Mg (wt%) alloy processed through combined hot extrusion (HE) and cold rolling (CR), followed by short-time heat treatment (CR + HT) at 200 °C was conducted. Besides, the influence of different annealing temperatures on the microstructure and mechanical properties was studied. An adequate combination of processing conditions during CR and HT successfully addressed brittleness obtained in the high-strength HE Zn-3Ag-0.5Mg alloy. By controlling the microstructure, the most promising results were obtained in the sample subjected to 50% CR reduction and 5-min annealing, which were: ultimate tensile strength of 432 MPa, yield strength of 385 MPa, total elongation to failure of 34%, and Vickers microhardness of 125 HV0.3. The obtained properties clearly exceed the mechanical benchmarks for biodegradable implant materials. Based on the conducted investigation, brittle multi-phase Zn alloys' mechanical performance can be substantially enhanced to provide sufficient plasticity by grain refinement through cold deformation process, followed by short-time annealing to restore proper strength.
Collapse
Affiliation(s)
- Maria Wątroba
- AGH University of Science and Technology, Faculty of Metals Engineering and Industrial Computer Science, Al. A. Mickiewicza 30, 30-059 Krakow, Poland
| | - Wiktor Bednarczyk
- AGH University of Science and Technology, Faculty of Metals Engineering and Industrial Computer Science, Al. A. Mickiewicza 30, 30-059 Krakow, Poland
| | - Jakub Kawałko
- AGH University of Science and Technology, Academic Centre for Materials and Nanotechnology, Al. A. Mickiewicza 30, 30-059 Krakow, Poland
| | - Piotr Bała
- AGH University of Science and Technology, Faculty of Metals Engineering and Industrial Computer Science, Al. A. Mickiewicza 30, 30-059 Krakow, Poland.,AGH University of Science and Technology, Academic Centre for Materials and Nanotechnology, Al. A. Mickiewicza 30, 30-059 Krakow, Poland
| |
Collapse
|
36
|
Kabir H, Munir K, Wen C, Li Y. Recent research and progress of biodegradable zinc alloys and composites for biomedical applications: Biomechanical and biocorrosion perspectives. Bioact Mater 2021; 6:836-879. [PMID: 33024903 PMCID: PMC7530311 DOI: 10.1016/j.bioactmat.2020.09.013] [Citation(s) in RCA: 96] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 09/16/2020] [Accepted: 09/17/2020] [Indexed: 12/22/2022] Open
Abstract
Biodegradable metals (BMs) gradually degrade in vivo by releasing corrosion products once exposed to the physiological environment in the body. Complete dissolution of biodegradable implants assists tissue healing, with no implant residues in the surrounding tissues. In recent years, three classes of BMs have been extensively investigated, including magnesium (Mg)-based, iron (Fe)-based, and zinc (Zn)-based BMs. Among these three BMs, Mg-based materials have undergone the most clinical trials. However, Mg-based BMs generally exhibit faster degradation rates, which may not match the healing periods for bone tissue, whereas Fe-based BMs exhibit slower and less complete in vivo degradation. Zn-based BMs are now considered a new class of BMs due to their intermediate degradation rates, which fall between those of Mg-based BMs and Fe-based BMs, thus requiring extensive research to validate their suitability for biomedical applications. In the present study, recent research and development on Zn-based BMs are reviewed in conjunction with discussion of their advantages and limitations in relation to existing BMs. The underlying roles of alloy composition, microstructure, and processing technique on the mechanical and corrosion properties of Zn-based BMs are also discussed.
Collapse
Affiliation(s)
- Humayun Kabir
- School of Engineering, RMIT University, Melbourne, Victoria, 3001, Australia
| | - Khurram Munir
- School of Engineering, RMIT University, Melbourne, Victoria, 3001, Australia
| | - Cuie Wen
- School of Engineering, RMIT University, Melbourne, Victoria, 3001, Australia
| | - Yuncang Li
- School of Engineering, RMIT University, Melbourne, Victoria, 3001, Australia
| |
Collapse
|
37
|
Xu Y, Xepapadeas AB, Koos B, Geis-Gerstorfer J, Li P, Spintzyk S. Effect of post-rinsing time on the mechanical strength and cytotoxicity of a 3D printed orthodontic splint material. Dent Mater 2021; 37:e314-e327. [PMID: 33610310 DOI: 10.1016/j.dental.2021.01.016] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2019] [Revised: 12/13/2020] [Accepted: 01/20/2021] [Indexed: 02/08/2023]
Abstract
OBJECTIVE Since the post-rinsing time is inconsistently recommended, this study aims to investigate the effect of post-rinsing time on the flexural strength and cytotoxicity of an stereolithographically (SLA) printed orthodontic splint material. METHODS SLA-printed specimens were ultrasonically rinsed with isopropanol (IPA) for 5 min, 12 min, 20 min, 30 min, 1 h, and 12 h, respectively. Surface characterization was conducted by scanning electron microscopy and roughness measurements. Flexural strength was evaluated using a three-point bending test. Cytotoxicity was determined by direct contact test and extract test. For both tests, cell viability (live/dead staining) and cell metabolic activity (CCK-8 assay) were evaluated. Additionally, water sorption and water solubility were tested to analyze the mass loss from immersion. RESULTS No apparent surface alterations could be detected on the samples post-rinsed for less than 1 h. In contrast, when the post-rinsing time was prolonged to 12 h, surface fissures could be observed. Flexural strength linearly decreased with increasing post-rinsing time. All post-processed specimens did not show an obvious cytotoxic effect. SIGNIFICANCE The removal of cytotoxic methacrylate monomers by post-rinsing with IPA could be achieved in 5 min. Extending post-rinsing time could not improve the cytocompatibility of the SLA-printed orthodontic splint material, and may result in a decrease in flexural strength.
Collapse
Affiliation(s)
- Yichen Xu
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China; Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China; University Hospital Tübingen, Section Medical Materials Science and Technology, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Alexander B Xepapadeas
- Department of Orthodontics, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Bernd Koos
- Department of Orthodontics, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Jürgen Geis-Gerstorfer
- University Hospital Tübingen, Section Medical Materials Science and Technology, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Ping Li
- University Hospital Tübingen, Section Medical Materials Science and Technology, Osianderstrasse 2-8, Tübingen 72076, Germany.
| | - Sebastian Spintzyk
- University Hospital Tübingen, Section Medical Materials Science and Technology, Osianderstrasse 2-8, Tübingen 72076, Germany
| |
Collapse
|
38
|
Čapek J, Kubásek J, Pinc J, Fojt J, Krajewski S, Rupp F, Li P. Microstructural, mechanical, in vitro corrosion and biological characterization of an extruded Zn-0.8Mg-0.2Sr (wt%) as an absorbable material. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 122:111924. [PMID: 33641917 DOI: 10.1016/j.msec.2021.111924] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 12/29/2020] [Accepted: 01/15/2021] [Indexed: 12/23/2022]
Abstract
Zinc (Zn) alloys seem to be promising candidates for application in orthopaedic or cardiovascular medical implants. In this area, high standards are required regarding the biocompatibility as well as excellent mechanical and tailored degradation properties. In the presented study, a novel Zn-0.8Mg-0.2Sr (wt%) alloy has been fabricated by the combination of casting, homogenization annealing and extrusion at 200 °C. As a consequence of its fine-grained homogenous microstructure, the prepared material is characterized by an excellent combination of tensile yield strength, ultimate tensile strength and elongation corresponding to 244 MPa, 324 MPa and 20% respectively. The in vitro corrosion rates of the Zn-0.8Mg-0.2Sr alloy in the physiological solution and the simulated body fluid were 244 μm/a and 69.8 μm/a, respectively. Furthermore, an extract test revealed that Zn-0.8Mg-0.2Sr extracts diluted to 25% had no adverse effects towards L929 fibroblasts, TAg periosteal cells and Saos-2 osteoblasts. Moreover, the Zn-0.8Mg-0.2Sr surface showed effective inhibition of initial Streptococcus gordonii adhesion and biofilm formation. These results indicated the Zn-0.8Mg-0.2Sr alloy, which has superior mechanical properties, might be a promising candidate for materials used for load-bearing applications.
Collapse
Affiliation(s)
- Jaroslav Čapek
- FZU - The Institute of Physics, Czech Academy of Sciences, Na Slovance 1999/2, Prague 8 182 21, Czech Republic
| | - Jiří Kubásek
- Institute of Metals and Corrosion Engineering, University of Chemistry and Technology, Technická 6, Prague 6, 166 28, Czech Republic
| | - Jan Pinc
- FZU - The Institute of Physics, Czech Academy of Sciences, Na Slovance 1999/2, Prague 8 182 21, Czech Republic
| | - Jaroslav Fojt
- Institute of Metals and Corrosion Engineering, University of Chemistry and Technology, Technická 6, Prague 6, 166 28, Czech Republic
| | - Stefanie Krajewski
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Frank Rupp
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
| | - Ping Li
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany.
| |
Collapse
|
39
|
Zhang W, Li P, Shen G, Mo X, Zhou C, Alexander D, Rupp F, Geis-Gerstorfer J, Zhang H, Wan G. Appropriately adapted properties of hot-extruded Zn-0.5Cu-xFe alloys aimed for biodegradable guided bone regeneration membrane application. Bioact Mater 2020; 6:975-989. [PMID: 33102940 PMCID: PMC7560602 DOI: 10.1016/j.bioactmat.2020.09.019] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 09/18/2020] [Accepted: 09/18/2020] [Indexed: 12/27/2022] Open
Abstract
Appropriately adapted comprehensive mechanical properties, degradation behavior and biocompatibility are prerequisites for the application of Zn-based biodegradable implants. In this study, hot-extruded Zn-0.5Cu-xFe (x = 0.1, 0.2 and 0.4 wt%) alloys were fabricated as candidates for biodegradable materials for guided bone regeneration (GBR) membranes. The hot-extrusion process and Cu alloying were expected mostly to enhance the mechanical properties, and the Fe alloying was added mainly for regulating the degradation. The microstructure, mechanical properties and in vitro degradation behavior were systematically investigated. The ZnCuFe alloys were composed of a Zn matrix and FeZn13 phase. With increasing Fe content, a higher FeZn13 phase precipitation with larger particles was observed. Since elongation declined significantly until fracture with increasing Fe content up to 0.4 wt%, the ZnCuFe (0.2 wt%) alloy achieved a good balance between mechanical strength and ductility, with an ultimate tensile strength of 202.3 MPa and elongation at fracture of 41.2%. Moreover, the addition of Fe successfully accelerated the degradation of ZnCuFe alloys. The ZnCuFe (0.2 wt%) alloy showed relatively uniform corrosion in the long-term degradation test. Furthermore, extracts of the ZnCuFe (0.2 wt%) alloy showed no apparent cytotoxic effects against L929 fibroblasts, Saos-2 osteoblasts or TAg periosteal cells. The ZnCuFe (0.2 wt%) alloy exhibited the potential to inhibit bacterial adhesion of Streptococcus gordonii and mixed oral bacteria. Our study provides evidence that the ZnCuFe (0.2 wt%) alloy can represent a promising material for the application as a suitable GBR membrane.
Collapse
Affiliation(s)
- Wentai Zhang
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Ping Li
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen, 72076, Germany
| | - Gang Shen
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Xiaoshan Mo
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Chao Zhou
- Beijing Advanced Innovation Center for Materials Genome Engineering, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing, 100083, China
| | - Dorothea Alexander
- Department of Oral and Maxillofacial Surgery, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen, 72076, Germany
| | - Frank Rupp
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen, 72076, Germany
| | - Jürgen Geis-Gerstorfer
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen, 72076, Germany.,Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen, 72076, Germany
| | - Haijun Zhang
- Department of Interventional and Vascular Surgery, The Tenth People's Hospital of Shanghai, Tongji University, Shanghai, 200072, China.,National United Engineering Laboratory for Biomedical Material Modification, Branden Industrial Park, Qihe Economic & Development Zone, Dezhou, Shandong, 251100, China
| | - Guojiang Wan
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| |
Collapse
|
40
|
Zhang W, Li P, Neumann B, Haag H, Li M, Xu Z, Zhou C, Scheideler L, Wendel HP, Zhang H, Geis-Gerstorfer J, Wan G. Chandler-Loop surveyed blood compatibility and dynamic blood triggered degradation behavior of Zn-4Cu alloy and Zn. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 119:111594. [PMID: 33321638 DOI: 10.1016/j.msec.2020.111594] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 09/16/2020] [Accepted: 09/30/2020] [Indexed: 12/16/2022]
Abstract
Zinc (Zn) and its alloys have been considered promising absorbable metals for medical implants. However, the dynamic interaction between Zn-based materials and human blood after implantation remains unclear. In this study, a modified Chandler-Loop system was applied to assess the blood compatibility and initial degradation behavior of a Zn-4.0Cu (wt%) alloy (Zn-4Cu) and Zn with human peripheral blood under circulation conditions. In this dynamic in vitro model, the Zn-4Cu and Zn showed sufficient blood compatibility. The numbers of erythrocytes, platelets, and leukocytes were not significantly altered, and appropriate activations of the coagulation and complement system were observed. Concerning initial degradation behavior, the product layers formed on the surfaces comprise a mixture of organic and inorganic compounds while the inorganic constituents decrease toward the outer surface. Considering the corrosion morphology and electrochemical behaviors, Zn-4Cu exhibited milder and more uniform degradation than Zn. Additionally, long-term degradation tests of 28 days in human peripheral blood, human serum, and Dulbecco's phosphate-buffered saline (DPBS) demonstrated that the Zn-4Cu showed relatively uniform degradation in blood and serum. On the contrary, in DPBS, severe localized corrosion appeared along the grain boundary of the secondary phase, which was likely attributed to the acceleration of galvanic corrosion. The Zn was found with localized corrosion impeded in the blood albeit with apparently developed deep pitting holes in the serum and DPBS.
Collapse
Affiliation(s)
- Wentai Zhang
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Ping Li
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstr. 2-8, Tübingen 72076, Germany
| | - Bernd Neumann
- Department of Cardiovascular Surgery, Clinical Research Laboratory, University Hospital Tübingen, Calwerstr. 7/1, Tübingen 72076, Germany
| | - Hanna Haag
- Department of Cardiovascular Surgery, Clinical Research Laboratory, University Hospital Tübingen, Calwerstr. 7/1, Tübingen 72076, Germany
| | - Ming Li
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Zeqian Xu
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstr. 2-8, Tübingen 72076, Germany
| | - Chao Zhou
- Beijing Advanced Innovation Center for Materials Genome Engineering, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Lutz Scheideler
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstr. 2-8, Tübingen 72076, Germany
| | - Hans-Peter Wendel
- Department of Cardiovascular Surgery, Clinical Research Laboratory, University Hospital Tübingen, Calwerstr. 7/1, Tübingen 72076, Germany
| | - Haijun Zhang
- Department of Interventional and Vascular Surgery, The Tenth People's Hospital of Shanghai, Tongji University, Shanghai 200072, China; National United Engineering Laboratory for Biomedical Material Modification, Branden Industrial Park, Qihe Economic & Development Zone, Dezhou, Shandong 251100, China.
| | - Jürgen Geis-Gerstorfer
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstr. 2-8, Tübingen 72076, Germany.
| | - Guojiang Wan
- Key Laboratory of Advanced Technologies of Materials, Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
| |
Collapse
|
41
|
Insight into role and mechanism of Li on the key aspects of biodegradable Zn Li alloys: Microstructure evolution, mechanical properties, corrosion behavior and cytotoxicity. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 114:111049. [DOI: 10.1016/j.msec.2020.111049] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2020] [Revised: 04/26/2020] [Accepted: 05/01/2020] [Indexed: 12/18/2022]
|
42
|
Pathak DK, Pandey PM. Evaluation of in vitro corrosion behavior of zinc-hydroxyapatite and zinc-hydroxyapatite-iron as biodegradable composites. J Biomed Mater Res B Appl Biomater 2020; 109:436-450. [PMID: 32864845 DOI: 10.1002/jbm.b.34712] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 08/09/2020] [Accepted: 08/13/2020] [Indexed: 12/21/2022]
Abstract
Zinc (Zn) based biomaterials have been emerged as one of the capable biodegradable materials for biomedical applications because of the ideal degradation properties. In the present work, corrosion kinetics of Zn-hydroxyapatite (HA), and Zn-HA-iron (Fe) materials developed using microwave sintering process were investigated. The effect of the inclusion of HA and Fe in Zn on corrosion properties have been evaluated in the simulated body fluid solution. Further, the wettability test of the developed composites was performed to confirm the hydrophilic nature of the surface of all samples. Zn-3HA was found to have better hydrophilicity as compared to other samples. Increased corrosion rate and pH of Zn-5HA-2Fe samples were attributed to the addition of HA and Fe in the Zn matrix. The corrosion rate and weight loss rate from electrochemical and immersion testing of all samples were found in the order from highest to lowest: Zn-5HA-2Fe > Zn-3HA > Zn-3HA-2Fe > Zn. The highest cell viability nearly 100% was obtained for Zn-3HA samples, whereas other samples also showed sufficient biocompatibility to be utilized for biomedical applications.
Collapse
Affiliation(s)
| | - Pulak Mohan Pandey
- Department of Mechanical Engineering, Indian Institute of Technology, Delhi, New Delhi, India
| |
Collapse
|
43
|
Lietaert K, Zadpoor AA, Sonnaert M, Schrooten J, Weber L, Mortensen A, Vleugels J. Mechanical properties and cytocompatibility of dense and porous Zn produced by laser powder bed fusion for biodegradable implant applications. Acta Biomater 2020; 110:289-302. [PMID: 32348917 DOI: 10.1016/j.actbio.2020.04.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Revised: 03/30/2020] [Accepted: 04/02/2020] [Indexed: 02/02/2023]
Abstract
In this work, the macrotexture of dense Zn produced by laser powder bed fusion (LPBF) was studied and the mechanical properties for different tensile bar orientations were measured. The compressive strength of LPBF Zn scaffolds with five different unit cells was measured for a relative density of 20-51%. In addition, the response of mesenchymal stem cells to the LPBF Zn scaffolds was studied. The elastic modulus and yield strength of dense LPBF Zn were 110.0 ± 0.2 GPa and 78.0 ± 0.4 MPa, respectively in the vertical and 81.0 ± 0.4 GPa and 55.0 ± 0.7 MPa in the horizontal direction. This could be explained by the preferential orientation of the 〈0001〉 direction in the building plane. For LPBF Zn scaffolds, the plateau stress for the different unit cells varied between 8 and 33 MPa for a 30% relative density. Calcein staining, lactate production and DNA measurements over a 13-day period showed that mesenchymal stem cell viability was low for Zn scaffolds. This work forms a basis for further research into the LPBF texture formation of metals with hexagonal crystal structure, guides implant designers in scaffold unit cell and relative density selection and motivates further research into the cytocompatibility of LPBF Zn. STATEMENT OF SIGNIFICANCE: Laser powder bed fusion (LPBF) is a manufacturing technology which allows the seamless combination of porous and non-porous volumes in a metallic implant and is used in the orthopedic manufacturing industry today. The production of highly dense Zn with LPBF has been described earlier, but the mechanical properties of the resulting material have not been studied in detail yet. This study is the first to report on (i) the influence of different scanning strategies on the macrotexture of dense LPBF Zn and the resulting anisotropy of its mechanical properties, (ii) the relationship between the relative density and strength for LPBF Zn scaffolds with five different unit cells and (iii) the in vitro response of mesenchymal stem cells to these scaffolds.
Collapse
|
44
|
Jia B, Yang H, Han Y, Zhang Z, Qu X, Zhuang Y, Wu Q, Zheng Y, Dai K. In vitro and in vivo studies of Zn-Mn biodegradable metals designed for orthopedic applications. Acta Biomater 2020; 108:358-372. [PMID: 32165194 DOI: 10.1016/j.actbio.2020.03.009] [Citation(s) in RCA: 75] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 03/01/2020] [Accepted: 03/04/2020] [Indexed: 12/24/2022]
Abstract
In recent years, Zn-based materials provide a new option as biodegradable metals for orthopedic applications. To improve the low strength and brittle nature of pure Zn, small amounts of alloying element Mn (0.1, 0.4 and 0.8 wt.%) were added into Zn to fabricate binary Zn-Mn alloys. An extremely high elongation (83.96 ± 2.36%) was achieved in the resulting Zn-0.8 wt.%Mn alloy. Moreover, Zn-Mn alloys displayed significantly improved cytocompatibility as compared to pure Zn, according to cell proliferation and morphology analyses. More importantly, a significantly improved osteogenic activity was verified after adding Mn regarding ALP activity and osteogenic expression. Furthermore, Zn-0.8 wt.%Mn alloy scaffolds were implanted into the rat femoral condyle for repairing bone defects with pure Ti as control. Enhanced osteogenic activities were confirmed for Zn-0.8Mn alloy in contrast to pure Ti based on Micro-CT and histological results, and favorable in vivo biosafety of Zn-0.8Mn alloy was verified by H&E staining and blood tests. The exceptional mechanical performance and favorable osteogenic capability render Zn-Mn alloy a promising candidate material in the treatment of bone defects or fracture repair. STATEMENT OF SIGNIFICANCE: The element Mn, on the one hand, as an essential trace element in the human body, promotes cell proliferation, adhesion, spreading, and regulates bone metabolism; on the other hand, it could significantly improve the ductility of Zn alloys. Here, we systematically reported the biocompatibility and biofunctionality of binary biodegradable Zn-Mn alloys in the bone environment. The Zn-Mn alloys promoted MC3T3-E1 cell proliferation, adhesion, spreading, and osteogenic differentiation in vitro. Furthermore, a rat femoral condyle defect model was established; porous Zn-Mn alloy scaffolds were manufactured to repair the bone defects. Significant bone regenerations, considerable bone ingrowth, and desirable biosafety were confirmed in vivo. Therefore, biodegradable Zn-Mn with promising osteogenic properties may become new options for orthopedic implant materials.
Collapse
|
45
|
Evaluation of a Zn-2Ag-1.8Au-0.2V Alloy for Absorbable Biocompatible Materials. MATERIALS 2019; 13:ma13010056. [PMID: 31861956 PMCID: PMC6981962 DOI: 10.3390/ma13010056] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 12/13/2019] [Accepted: 12/16/2019] [Indexed: 02/01/2023]
Abstract
Zinc (Zn) and Zn-based alloys have been proposed as a new generation of absorbable metals mainly owing to the moderate degradation behavior of zinc between magnesium and iron. Nonetheless, mechanical strength of pure Zn is relatively poor, making it insufficient for the majority of clinical applications. In this study, a novel Zn–2Ag–1.8Au–0.2V (wt.%) alloy (Zn–Ag–Au–V) was fabricated and investigated for use as a potential absorbable biocompatible material. Microstructural characterization indicated an effective grain-refining effect on the Zn alloy after a thermomechanical treatment. Compared to pure Zn, the Zn–Ag–Au–V alloy showed significantly enhanced mechanical properties, with a yield strength of 168 MPa, an ultimate tensile strength of 233 MPa, and an elongation of 17%. Immersion test indicated that the degradation rate of the Zn–Ag–Au–V alloy in Dulbecco’s phosphate buffered saline was approximately 7.34 ± 0.64 μm/year, thus being slightly lower than that of pure Zn. Biocompatibility tests with L929 and Saos-2 cells showed a moderate cytotoxicity, alloy extracts at 16.7%, and 10% concentration did not affect metabolic activity and cell proliferation. Plaque formation in vitro was reduced, the Zn–Ag–Au–V surface inhibited adhesion and biofilm formation by the early oral colonizer Streptococcus gordonii, indicating antibacterial properties of the alloy.
Collapse
|