1
|
Liang S, Fu K, Li X, Wang Z. Unveiling the spatiotemporal dynamics of membrane fouling: A focused review on dynamic fouling characterization techniques and future perspectives. Adv Colloid Interface Sci 2024; 328:103179. [PMID: 38754212 DOI: 10.1016/j.cis.2024.103179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 03/12/2024] [Accepted: 05/03/2024] [Indexed: 05/18/2024]
Abstract
Membrane technology has emerged as a crucial method for obtaining clean water from unconventional sources in the face of water scarcity. It finds wide applications in wastewater treatment, advanced treatment, and desalination of seawater and brackish water. However, membrane fouling poses a huge challenge that limits the development of membrane-based water treatment technologies. Characterizing the dynamics of membrane fouling is crucial for understanding its development, mechanisms, and effective mitigation. Instrumental techniques that enable in situ or real-time characterization of the dynamics of membrane fouling provide insights into the temporal and spatial evolution of fouling, which play a crucial role in understanding the fouling mechanism and the formulation of membrane control strategies. This review consolidates existing knowledge about the principal advanced instrumental analysis technologies employed to characterize the dynamics of membrane fouling, in terms of membrane structure, morphology, and intermolecular forces. Working principles, applications, and limitations of each technique are discussed, enabling researchers to select appropriate methods for their specific studies. Furthermore, prospects for the future development of dynamic characterization techniques for membrane fouling are discussed, underscoring the need for continued research and innovation in this field to overcome the challenges posed by membrane fouling.
Collapse
Affiliation(s)
- Shuling Liang
- School of Environmental Science and Engineering, Shanghai Institute of Pollution Control and Ecological Security, State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China
| | - Kunkun Fu
- School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai 200092, China
| | - Xuesong Li
- School of Environmental Science and Engineering, Shanghai Institute of Pollution Control and Ecological Security, State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China.
| | - Zhiwei Wang
- School of Environmental Science and Engineering, Shanghai Institute of Pollution Control and Ecological Security, State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China
| |
Collapse
|
2
|
Wu J, Deng J, Theocharidis G, Sarrafian TL, Griffiths LG, Bronson RT, Veves A, Chen J, Yuk H, Zhao X. Adhesive anti-fibrotic interfaces on diverse organs. Nature 2024; 630:360-367. [PMID: 38778109 PMCID: PMC11168934 DOI: 10.1038/s41586-024-07426-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 04/16/2024] [Indexed: 05/25/2024]
Abstract
Implanted biomaterials and devices face compromised functionality and efficacy in the long term owing to foreign body reactions and subsequent formation of fibrous capsules at the implant-tissue interfaces1-4. Here we demonstrate that an adhesive implant-tissue interface can mitigate fibrous capsule formation in diverse animal models, including rats, mice, humanized mice and pigs, by reducing the level of infiltration of inflammatory cells into the adhesive implant-tissue interface compared to the non-adhesive implant-tissue interface. Histological analysis shows that the adhesive implant-tissue interface does not form observable fibrous capsules on diverse organs, including the abdominal wall, colon, stomach, lung and heart, over 12 weeks in vivo. In vitro protein adsorption, multiplex Luminex assays, quantitative PCR, immunofluorescence analysis and RNA sequencing are additionally carried out to validate the hypothesis. We further demonstrate long-term bidirectional electrical communication enabled by implantable electrodes with an adhesive interface over 12 weeks in a rat model in vivo. These findings may offer a promising strategy for long-term anti-fibrotic implant-tissue interfaces.
Collapse
Affiliation(s)
- Jingjing Wu
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Jue Deng
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Georgios Theocharidis
- Joslin-Beth Israel Deaconess Foot Center and The Rongxiang Xu, MD, Center for Regenerative Therapeutics, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | | | - Leigh G Griffiths
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | | | - Aristidis Veves
- Joslin-Beth Israel Deaconess Foot Center and The Rongxiang Xu, MD, Center for Regenerative Therapeutics, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Jianzhu Chen
- Koch Institute for Integrative Cancer Research and Department of Biology, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Hyunwoo Yuk
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
- SanaHeal, Cambridge, MA, USA.
| | - Xuanhe Zhao
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
- Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
| |
Collapse
|
3
|
Roca S, Leclercq L, Cottet H. Size-based characterization of dendrigraft poly(L-lysine) by free solution capillary electrophoresis using polyelectrolyte multilayer coatings. J Chromatogr A 2024; 1718:464719. [PMID: 38340458 DOI: 10.1016/j.chroma.2024.464719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 01/28/2024] [Accepted: 02/03/2024] [Indexed: 02/12/2024]
Abstract
Dendrigraft poly(L-lysine) (DGL) constitutes a promising dendritic-like drug vehicle with high biocompatibility and straightforward access via ring-opening polymerization of N-carboxyanhydride in water. The characterization of the different generations of DGL is however challenging due to their heterogeneity in molar mass and branching ratio. In this work, free solution capillary electrophoresis was used to perform selective separation of the three first generations of DGL, and optimized conditions were developed to maximize inter-generation resolution. To reduce solute adsorption on the capillary wall, successive multiple ionic polymer layer coatings terminated with a polycation were deposited onto the inner wall surface. PEGylated polycation was also used as the last layer for the control of the electroosmotic flow (EOF), depending on the PEGylation degree and the methyl-polyethylene glycol (mPEG) chain length. 1 kDa mPEG chains and low grafting densities were found to be the best experimental conditions for a fine tuning of the EOF leading to high peak resolution. Molar mass polydispersity and polydispersity in effective electrophoretic mobility were successfully determined for the three first generations of DGL.
Collapse
Affiliation(s)
- Sébastien Roca
- IBMM, University of Montpellier, CNRS, ENSCM, Montpellier, France
| | - Laurent Leclercq
- IBMM, University of Montpellier, CNRS, ENSCM, Montpellier, France.
| | - Hervé Cottet
- IBMM, University of Montpellier, CNRS, ENSCM, Montpellier, France.
| |
Collapse
|
4
|
Hayes B, Murphy C, Marquez Rubio J, Solis D, Jayaram K, MacCurdy R. Characterization of organic fouling on thermal bubble-driven micro-pumps. BIOFOULING 2024; 40:290-304. [PMID: 38785127 DOI: 10.1080/08927014.2024.2353034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 05/02/2024] [Indexed: 05/25/2024]
Abstract
Thermal bubble-driven micro-pumps are an upcoming micro-actuator technology that can be directly integrated into micro/mesofluidic channels, have no moving parts, and leverage existing mass production fabrication approaches. These micro-pumps consist of a high-power micro-resistor that boils fluid in microseconds to create a high-pressure vapor bubble which performs mechanical work. As such, these micro-pumps hold great promise for micro/mesofluidic systems such as lab-on-a-chip technologies. However, to date, no current work has studied the interaction of these micro-pumps with biofluids such as blood and protein-rich fluids. In this study, the effects of organic fouling due to egg albumin and bovine whole blood are characterized using stroboscopic high-speed imaging and a custom deep learning neural network based on transfer learning of RESNET-18. It was found that the growth of a fouling film inhibited vapor bubble formation. A new metric to quantify the extent of fouling was proposed using the decrease in vapor bubble area as a function of the number of micro-pump firing events. Fouling due to egg albumin and bovine whole blood was found to significantly degrade pump performance as well as the lifetime of thermal bubble-driven micro-pumps to less than 104 firings, which may necessitate the use of protective thin film coatings to prevent the buildup of a fouling layer.
Collapse
Affiliation(s)
- Brandon Hayes
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, Colorado, USA
| | - Cillian Murphy
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, Colorado, USA
- School of Mechanical and Materials Engineering, University College Dublin, Dublin, Ireland
| | - Janeth Marquez Rubio
- Department of Biomedical Engineering, University of Colorado Boulder, Boulder, Colorado, USA
| | - Daimean Solis
- Department of Biomedical Engineering, University of Colorado Boulder, Boulder, Colorado, USA
| | - Kaushik Jayaram
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, Colorado, USA
| | - Robert MacCurdy
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, Colorado, USA
| |
Collapse
|
5
|
Wang S, Dong X, Li J, Liu J, Ruan Y, Xia Y. Design of a Facile Antifouling Sensor Based on the Synergy between an Antibody and Phase-Transited BSA. BIOSENSORS 2023; 13:1004. [PMID: 38131764 PMCID: PMC10741890 DOI: 10.3390/bios13121004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 11/21/2023] [Accepted: 11/24/2023] [Indexed: 12/23/2023]
Abstract
Nonspecific adsorption has always been a critical challenge for sensor detection; thus, an efficient and facile approach for fabricating antifouling sensors is highly desirable. Here, we developed an antifouling coating on sensor surfaces, conveniently made with a simple drip of phase-transited BSA (PTB) followed by a modification with a peanut allergen antibody, which unexpectedly provides synergistic antifouling properties in sensors. Atomic force microscopy and scanning electron microscopy were used to evaluate the surface evenness. Optimizations in terms of PTB modification time and concentrations were performed using surface plasmon resonance by measuring protein resistance capabilities. Compared to bare Au surfaces, the PTB-modified surfaces exhibited low adsorption against BSA (<10 ng/cm2) and good resistance against lysozyme (Lyz). After immobilizing antibodies, the antifouling performance of the sensor coatings had an obvious enhancement, with almost no BSA adsorption and low lysozyme adsorption. The target recognition was also analyzed to verify the good sensing performance of the antifouling sensor. This understanding of antibody synergy provides suggestions for the development of antifouling sensors.
Collapse
Affiliation(s)
- Siqi Wang
- College of Chemistry and Pharmacy, Northwest A&F University, Yangling 712100, China;
| | - Xinru Dong
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, China; (X.D.); (J.L.); (J.L.); (Y.R.)
| | - Jialu Li
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, China; (X.D.); (J.L.); (J.L.); (Y.R.)
| | - Jialei Liu
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, China; (X.D.); (J.L.); (J.L.); (Y.R.)
| | - Yifei Ruan
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, China; (X.D.); (J.L.); (J.L.); (Y.R.)
| | - Yinqiang Xia
- College of Food Science and Engineering, Northwest A&F University, Yangling 712100, China; (X.D.); (J.L.); (J.L.); (Y.R.)
| |
Collapse
|
6
|
Sharbatian A, Devkota K, Ashouri Vajari D, Stieglitz T. From Bioinspired Topographies toward Non-Wettable Neural Implants. MICROMACHINES 2023; 14:1846. [PMID: 37893283 PMCID: PMC10609157 DOI: 10.3390/mi14101846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 09/21/2023] [Accepted: 09/26/2023] [Indexed: 10/29/2023]
Abstract
The present study investigates different design strategies to produce non-wettable micropatterned surfaces. In addition to the classical method of measuring the contact angle, the non-wettability is also discussed by means of the immersion test. Inspired by non-wettable structures found in nature, the effects of features such as reentrant cavities, micropillars, and overhanging layers are studied. We show that a densely populated array of small diameter cavities exhibits superior non-wettability, with 65% of the cavities remaining intact after 24 h of full immersion in water. In addition, it is suggested that the wetting transition time is influenced by the length of the overhanging layer as well as by the number of columns within the cavity. Our findings indicate a non-wetting performance that is three times longer than previously reported in the literature for a small, densely populated design with cavities as small as 10 μm in diameter. Such properties are particularly beneficial for neural implants as they may reduce the interface between the body fluid and the solid state, thereby minimiing the inflammatory response following implantation injury. In order to assess the effectiveness of this approach in reducing the immune response induced by neural implants, further in vitro and in vivo studies will be essential.
Collapse
Affiliation(s)
- Ali Sharbatian
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110 Freiburg, Germany; (A.S.); (T.S.)
- BrainLinks BrainTools, Institute for Machine-Brain Interfacing Technology (IMBIT), University of Freiburg, 79110 Freiburg, Germany
| | - Kalyani Devkota
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110 Freiburg, Germany; (A.S.); (T.S.)
- BrainLinks BrainTools, Institute for Machine-Brain Interfacing Technology (IMBIT), University of Freiburg, 79110 Freiburg, Germany
| | - Danesh Ashouri Vajari
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110 Freiburg, Germany; (A.S.); (T.S.)
- BrainLinks BrainTools, Institute for Machine-Brain Interfacing Technology (IMBIT), University of Freiburg, 79110 Freiburg, Germany
| | - Thomas Stieglitz
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110 Freiburg, Germany; (A.S.); (T.S.)
- BrainLinks BrainTools, Institute for Machine-Brain Interfacing Technology (IMBIT), University of Freiburg, 79110 Freiburg, Germany
- Bernstein Center Freiburg, University of Freiburg, 79104 Freiburg, Germany
| |
Collapse
|
7
|
Lyu K, Zhao Y, Zhang M, Tang J, Zhang J, Liu Y, Bian X, Chen X, Chen H, Wang D. Tracking of Protein Adsorption on Poly(l-lactic acid) Film Surfaces: The Role of Molar Mass. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:13534-13545. [PMID: 37712535 DOI: 10.1021/acs.langmuir.3c01571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/16/2023]
Abstract
Poly(l-lactic acid) (PLLA) has been extensively utilized as a biomaterial for various biomedical applications. The first and one of the most critical steps upon contact with biological fluids is the adsorption of proteins on the material's surface. Understanding the behavior of protein adsorption is vital for guiding the synthesis and preparation of PLLA for biomedical purposes. In this study, total internal reflection fluorescence microscopy was employed to investigate the adsorption of human serum albumin (HSA) on PLLA films with different molar masses. We found that molar mass affects HSA adsorption in such a way that it affects only the adsorption rate constants, but not the desorption rate constants. Additionally, we observed that HSA adsorption is spatially heterogeneous and exhibits many strong binding sites regardless of the molar mass of the PLLA films. We found that the free volume of PLLA plays a crucial role in determining its water uptake capacity and surface hydration, consequently impacting the adsorption of HSA.
Collapse
Affiliation(s)
- Kaixuan Lyu
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, P. R. China
| | - Yuehua Zhao
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Miaomiao Zhang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Jilin Tang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Jidong Zhang
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Yanlong Liu
- Key Laboratory of Polymer Ecomaterials, Chinese Academy of Sciences, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Xinchao Bian
- Key Laboratory of Polymer Ecomaterials, Chinese Academy of Sciences, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Xuesi Chen
- Key Laboratory of Polymer Ecomaterials, Chinese Academy of Sciences, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Hongbo Chen
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Dapeng Wang
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, P. R. China
| |
Collapse
|
8
|
Modifying last layer in polyelectrolyte multilayer coatings for capillary electrophoresis of proteins. J Chromatogr A 2023; 1692:463837. [PMID: 36804799 DOI: 10.1016/j.chroma.2023.463837] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/23/2023] [Accepted: 01/27/2023] [Indexed: 02/04/2023]
Abstract
Protein adsorption on the inner wall of the fused silica capillary wall is an important concern for capillary electrophoresis (CE) analysis since it is mainly responsible for separation efficiency reduction. Successive Multiple Ionic-polymer Layers (SMIL) are used as capillary coatings to limit protein adsorption, but even low residual adsorption strongly impacts the separation efficiency, especially at high separation voltages. In this work, the influence of the chemical nature and the PEGylation of the polyelectrolyte deposited in the last layer of the SMIL coating was investigated on the separation performances of a mixture of four model intact proteins (myoglobin (Myo), trypsin inhibitor (TI), ribonuclease a (RNAse A) and lysozyme (Lyz)). Poly(allylamine hydrochloride) (PAH), polyethyleneimine (PEI), ε-poly(L-lysine) (εPLL) and α-poly(L-lysine) (αPLL) were compared before and after chemical modification with polyethyleneglycol (PEG) of different chain lengths. The experimental results obtained by performing electrophoretic separations at different separation voltages allowed determining the residual retention factor of the proteins onto the capillary wall via the determination of the plate height at different solute velocities and demonstrated a strong impact of the polycationic last layer on the electroosmotic mobility, the separation efficiency and the overall resolution. Properties of SMIL coatings were also characterized by quartz microbalance and atomic force microscopy, demonstrating a glassy structure of the films.
Collapse
|
9
|
Han Z, Song B, Yang J, Wang B, Ma Z, Yu L, Li Y, Xu H, Qiao M. Curcumin-Encapsulated Fusion Protein-Based Nanocarrier Demonstrated Highly Efficient Epidermal Growth Factor Receptor-Targeted Treatment of Colorectal Cancer. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022; 70:15464-15473. [PMID: 36454954 DOI: 10.1021/acs.jafc.2c04668] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Curcumin, a polyphenol derived from turmeric, has multiple biological functions, such as anti-inflammatory, antioxidant, antibacterial and, above all, antitumor activity. Colorectal cancer is a common malignancy of the gastrointestinal tract with an extremely high mortality rate. However, the low bioavailability and poor targeting properties of curcumin generally limit its clinical application. In the present study, we designed a fusion protein GE11-HGFI as a nanodrug delivery system. The protein was connected by flexible linkers, inheriting the self-assembly properties of hydrophobin HGFI and the targeting ability of GE11. The data show that the encapsulation of curcumin by fusion protein GE11-HGFI can form uniform and stable nanoparticles with a size of only 80 nm. In addition, the nanocarrier had high encapsulation efficiency for curcumin and made it to release sustainably. Notably, the drug-loaded nanosystem selectively targeted colorectal cancer cells with high epidermal growth factor receptor expression, resulting in high aggregated concentrations of curcumin at tumor sites, thus showing a significant anticancer effect. These results suggest that the nanocarrier fusion protein has the potential to be a novel strategy for enhancing molecular bioactivity and drug targeting in cancer therapy.
Collapse
Affiliation(s)
- Zhiqiang Han
- The Key Laboratory of Molecular Microbiology and Technology, Ministry of Education, College of Life Sciences, Nankai University, Tianjin 300071, P.R. China
| | - Bo Song
- The Key Laboratory of Molecular Microbiology and Technology, Ministry of Education, College of Life Sciences, Nankai University, Tianjin 300071, P.R. China
| | - Jiyuan Yang
- The Key Laboratory of Molecular Microbiology and Technology, Ministry of Education, College of Life Sciences, Nankai University, Tianjin 300071, P.R. China
| | - Bo Wang
- The Key Laboratory of Molecular Microbiology and Technology, Ministry of Education, College of Life Sciences, Nankai University, Tianjin 300071, P.R. China
| | - Zhongqiang Ma
- The Key Laboratory of Molecular Microbiology and Technology, Ministry of Education, College of Life Sciences, Nankai University, Tianjin 300071, P.R. China
| | - Long Yu
- The Key Laboratory of Molecular Microbiology and Technology, Ministry of Education, College of Life Sciences, Nankai University, Tianjin 300071, P.R. China
| | - Yuanhao Li
- Remegen Co., Ltd., Shandong 264000, P.R. China
| | - Haijin Xu
- The Key Laboratory of Molecular Microbiology and Technology, Ministry of Education, College of Life Sciences, Nankai University, Tianjin 300071, P.R. China
| | - Mingqiang Qiao
- The Key Laboratory of Molecular Microbiology and Technology, Ministry of Education, College of Life Sciences, Nankai University, Tianjin 300071, P.R. China
- School of Life Science, Shanxi University, Shanxi 030000, P.R. China
| |
Collapse
|
10
|
Vahabi H, Vallabhuneni S, Hedayati M, Wang W, Krapf D, Kipper MJ, Miljkovic N, Kota AK. Designing Non-Textured, All-Solid, Slippery Hydrophilic Surfaces. MATTER 2022; 5:4502-4512. [PMID: 36569514 PMCID: PMC9784614 DOI: 10.1016/j.matt.2022.09.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Slippery surfaces are sought after due to their wide range of applications in self-cleaning, drag reduction, fouling-resistance, enhanced condensation, biomedical implants etc. Recently, non-textured, all-solid, slippery surfaces have gained significant attention because of their advantages over super-repellent surfaces and lubricant-infused surfaces. Currently, almost all non-textured, all-solid, slippery surfaces are hydrophobic. In this work, we elucidate the systematic design of non-textured, all-solid, slippery hydrophilic (SLIC) surfaces by covalently grafting polyethylene glycol (PEG) brushes to smooth substrates. Furthermore, we postulate a plateau in slipperiness above a critical grafting density, which occurs when the tethered brush size is equal to the inter-tether distance. Our SLIC surfaces demonstrate exceptional performance in condensation and fouling-resistance compared to non-slippery hydrophilic surfaces and slippery hydrophobic surfaces. Based on these results, SLIC surfaces constitute an emerging class of surfaces with the potential to benefit multiple technological landscapes ranging from thermofluidics to biofluidics.
Collapse
Affiliation(s)
- Hamed Vahabi
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
- These authors contributed equally
| | - Sravanthi Vallabhuneni
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA
- These authors contributed equally
| | - Mohammadhasan Hedayati
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | - Wei Wang
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA
- Department of Mechanical, Aerospace and Biomedical Engineering, University of Tennessee, Knoxville, TN 37996, USA
| | - Diego Krapf
- Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | - Matt J. Kipper
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | - Nenad Miljkovic
- Department of Mechanical Science and Engineering, Department of Electrical and Computer Engineering, Materials Research Laboratory, University of Illinois at Urbana – Champaign, Urbana, IL 61801, USA
- International Institute of Carbon Neutral Energy Research (WPI-I2CNER), Kyushu University, 744 Motooka, Nishi-ku, Fukoka 819-0395, Japan
| | - Arun K. Kota
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA
- Lead contact
| |
Collapse
|
11
|
Lyu K, Chen H, Gao J, Jin J, Shi H, Schwartz DK, Wang D. Protein Desorption Kinetics Depends on the Timescale of Observation. Biomacromolecules 2022; 23:4709-4717. [PMID: 36205402 DOI: 10.1021/acs.biomac.2c00917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The presence of so-called reversible and irreversible protein adsorption on solid surfaces is well documented in the literature and represents the basis for the development of nanoparticles and implant materials to control interactions in physiological environments. Here, using a series of complementary single-molecule tracking approaches appropriate for different timescales, we show that protein desorption kinetics is much more complex than the traditional reversible-irreversible binary picture. Instead, we find that the surface residence time distribution of adsorbed proteins transitions from power law to exponential behavior when measured over a large range of timescales (10-2-106 s). A comparison with macroscopic results obtained using a quartz crystal microbalance suggested that macroscopic measurements have generally failed to observe such nonequilibrium phenomena because they are obscured by ensemble-averaging effects. These findings provide new insights into the complex phenomena associated with protein adsorption and desorption.
Collapse
Affiliation(s)
- Kaixuan Lyu
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China.,University of Science and Technology of China, Hefei 230026, P. R. China
| | - Hongbo Chen
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Jing Gao
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Jing Jin
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Hengchong Shi
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China
| | - Daniel K Schwartz
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, Colorado 80309, United States
| | - Dapeng Wang
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, P. R. China.,University of Science and Technology of China, Hefei 230026, P. R. China
| |
Collapse
|
12
|
Lazarenko HO, Boiko IV. THE METHOD OF ATOMIC FORCE MICROSCOPY AS A POSSIBLE TOOL FOR TESTING THE BIOCOMPATIBILITY OF IMPLANTS IN TRAUMATOLOGY AND ORTHOPEDICS PRACTICE. WIADOMOSCI LEKARSKIE (WARSAW, POLAND : 1960) 2022; 75:2614-2618. [PMID: 36591742 DOI: 10.36740/wlek202211111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
OBJECTIVE The aim: To establish the possibility of using the atomic force microscope (AFM) to predict the body's reaction to the implant. PATIENTS AND METHODS Materials and methods: A total of 32 patients, 22 men and 10 women, the average age of the patients was 55±6 years, were included in the study. They performed pre- and post-operative testing of the biocompatibility of orthopedic implant materials with the patient's body with the help of AFM. RESULTS Results: According to the research, an increase in pro-inflammatory factors was found, which may indicate a constant inflammatory process, which is probably related to the presence of the implant. CONCLUSION Conclusions: On the basis of atomic force spectroscopy, an express method of testing biomaterials for compatibility with the body of a specific recipient and studying the effect of the reactions of recipient tissues on the surface of various implants has been developed. The obtained results can be useful in planning further clinical studies.
Collapse
Affiliation(s)
- Hlib O Lazarenko
- STATE INSTITUTION OF SCIENCE «RESEARCH AND PRACTICAL CENTER OF PREVENTIVE AND CLINICAL MEDICINE», KYIV, UKRAINE, STATE ADMINISTRATIVE DEPARTMENT, KYIV, UKRAINE
| | - Igor V Boiko
- STATE INSTITUTION OF SCIENCE «RESEARCH AND PRACTICAL CENTER OF PREVENTIVE AND CLINICAL MEDICINE», KYIV, UKRAINE, STATE ADMINISTRATIVE DEPARTMENT, KYIV, UKRAINE
| |
Collapse
|
13
|
Masaike S, Sasaki S, Ebata H, Moriyama K, Kidoaki S. Adhesive-ligand-independent cell-shaping controlled by the lateral deformability of a condensed polymer matrix. Polym J 2021. [DOI: 10.1038/s41428-021-00577-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
14
|
Vlcek JR, Reynolds MM, Kipper MJ. Enzymatic Degradation of Glycosaminoglycans and Proteoglycan-Mimetic Materials in Solution and on Polyelectrolyte Multilayer Surfaces. Biomacromolecules 2021; 22:3913-3925. [PMID: 34347454 DOI: 10.1021/acs.biomac.1c00720] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Proteoglycans (PGs) play many important roles in biology, contributing to the mechanical properties of tissues, helping to organize extracellular matrix components, and participating in signaling mechanisms related to mechanotransduction, cell differentiation, immune responses, and wound healing. Our lab has designed two different types of PG mimics: polyelectrolyte complex nanoparticles (PCNs) and PG-mimetic graft copolymers (GCs), both of which are prepared using naturally occurring glycosaminoglycans. This work evaluates the enzymatic stability of these PG mimics using hyaluronidases (I-S, IV-S, and II), chondroitinase ABC, and lysozyme, for PG mimics suspended in solution and adsorbed onto surfaces. Hyaluronan (HA)- and chondroitin sulfate (CS)-containing PG mimics are degraded by the hyaluronidases. PCNs prepared with CS and GCs prepared with heparin are the only CS- and HA-containing PG mimics protected from chondroitinase ABC. None of the materials are measurably degraded by lysozyme. Adsorption to polyelectrolyte multilayer surfaces protects PG mimics from degradation, compared to when PG mimics are combined with enzymes in solution; all surfaces are still intact after 21 days of enzyme exposure. This work reveals how the stability of PG mimics is controlled by both the composition and macromolecular assembly of the PG mimic and also by the size and specificity of the enzyme. Understanding and tuning these degradation susceptibilities are essential for advancing their applications in cardiovascular materials, orthopedic materials, and growth factor delivery applications.
Collapse
Affiliation(s)
- Jessi R Vlcek
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Melissa M Reynolds
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States.,School of Advanced Materials Discovery, Colorado State University, Fort Collins, Colorado 80523, United States.,School of Advanced Materials Discovery, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Matt J Kipper
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States.,School of Advanced Materials Discovery, Colorado State University, Fort Collins, Colorado 80523, United States.,Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
15
|
Wang D, Stuart JD, Jones AA, Snow CD, Kipper MJ. Measuring interactions of DNA with nanoporous protein crystals by atomic force microscopy. NANOSCALE 2021; 13:10871-10881. [PMID: 34124715 DOI: 10.1039/d1nr01703a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Crosslinked porous protein crystals are a new biomaterial that can be engineered to encapsulate, stabilize, and organize guest molecules, nanoparticles, and biological moieties. In this study, for the first time, the combined interactions of DNA strands with porous protein crystals are quantitatively measured by high-resolution atomic force microscopy (AFM) and chemical force microscopy. The surface structure of protein crystals with unusually large pores was observed in liquid via high-resolution AFM. Force-distance (F-D) curves were also obtained using AFM tips modified to present or capture DNA. The modification of AFM tips allowed the tips to covalently bind DNA that was pre-loaded in the protein crystal nanopores. The modified tips enabled the interactions of DNA molecules with protein crystals to be quantitatively studied while revealing the morphology of the buffer-immersed protein crystal surface in detail, thereby preserving the structure and properties of protein crystals that could be disrupted or destroyed by drying. The hexagonal space group was manifest at the crystal surface, as were the strong interactions between DNA and the porous protein crystals in question. In sum, this study furthered our understanding of how a new protein-based biomaterial can be used to bind guest DNA assemblies.
Collapse
Affiliation(s)
- Dafu Wang
- School of Advanced Materials Discovery, Colorado State University, 1617 Campus Delivery, Fort Collins, CO 80523, USA and Department of Chemical and Biological Engineering, Colorado State University, 1370 Campus Delivery, Fort Collins, CO 80523, USA.
| | - Julius D Stuart
- Department of Chemistry, Colorado State University, 1872 Campus Delivery, Fort Collins, CO 80523, USA
| | - Alec A Jones
- School of Biomedical Engineering, Colorado State University, 1301 Campus Delivery, Fort Collins, CO 80523, USA
| | - Christopher D Snow
- School of Advanced Materials Discovery, Colorado State University, 1617 Campus Delivery, Fort Collins, CO 80523, USA and Department of Chemical and Biological Engineering, Colorado State University, 1370 Campus Delivery, Fort Collins, CO 80523, USA. and Department of Chemistry, Colorado State University, 1872 Campus Delivery, Fort Collins, CO 80523, USA and School of Biomedical Engineering, Colorado State University, 1301 Campus Delivery, Fort Collins, CO 80523, USA
| | - Matt J Kipper
- School of Advanced Materials Discovery, Colorado State University, 1617 Campus Delivery, Fort Collins, CO 80523, USA and Department of Chemical and Biological Engineering, Colorado State University, 1370 Campus Delivery, Fort Collins, CO 80523, USA. and School of Biomedical Engineering, Colorado State University, 1301 Campus Delivery, Fort Collins, CO 80523, USA
| |
Collapse
|
16
|
Vlcek JR, Hedayati M, Melvin AC, Reynolds MM, Kipper MJ. Blood-Compatible Materials: Vascular Endothelium-Mimetic Surfaces that Mitigate Multiple Cell-Material Interactions. Adv Healthc Mater 2021; 10:e2001748. [PMID: 33448158 DOI: 10.1002/adhm.202001748] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Indexed: 12/17/2022]
Abstract
When flowing whole blood contacts medical device surfaces, the most common blood-material interactions result in coagulation, inflammation, and infection. Many new blood-contacting biomaterials have been proposed based on strategies that address just one of these common modes of failure. This study proposes to mitigate unfavorable biological reactions that occur with blood-contacting medical devices by designing multifunctional surfaces, with features optimized to meet multiple performance criteria. These multifunctional surfaces incorporate the release of the small molecule hormone nitric oxide (NO) with surface chemistry and nanotopography that mimic features of the vascular endothelial glycocalyx. These multifunctional surfaces have features that interact with coagulation components, inflammatory cells, and bacterial cells. While a single surface feature alone may not be sufficient to achieve multiple functions, the release of NO from the surfaces along with their modification to mimic the endothelial glycocalyx synergistically improves platelet-, leukocyte-, and bacteria-surface interactions. This work demonstrates that new blood-compatible materials should be designed with multiple features, to better address the multiple modes of failure of blood-contacting medical devices.
Collapse
Affiliation(s)
- Jessica R. Vlcek
- School of Biomedical Engineering Colorado State University Fort Collins CO 80523 USA
| | - Mohammadhasan Hedayati
- Department of Chemical and Biological Engineering Colorado State University Fort Collins CO 80523 USA
| | - Alyssa C. Melvin
- Department of Chemistry Colorado State University Fort Collins CO 80532 USA
| | - Melissa M. Reynolds
- Department of Chemistry Department of Chemical and Biological Engineering, and School of Biomedical Engineering Colorado State University Fort Collins CO 80523 USA
| | - Matt J. Kipper
- Department of Chemical and Biological Engineering School of Biomedical Engineering, and School of Advanced Materials Discovery Colorado State University Fort Collins CO 80523 USA
| |
Collapse
|
17
|
Lefebvre G, Bruckert F, Filipe V, Huille S, Weidenhaupt M. Adsorption rate constants of therapeutic proteins and surfactants for material surfaces. Colloids Surf B Biointerfaces 2021; 203:111722. [PMID: 33839475 DOI: 10.1016/j.colsurfb.2021.111722] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 03/01/2021] [Accepted: 03/23/2021] [Indexed: 12/20/2022]
Abstract
Adsorption of therapeutic proteins to material surfaces can be a pivotal issue in drug development, especially for low concentration products. Surfactants are used to limit adsorption losses. For each formulation component, surface adsorption is the result of a combination of its diffusion and surface adsorption rates. The latter are difficult to measure accurately because a depletion layer forms rapidly in the bulk solution above a bare surface, slowing down adsorption. Adapting flow conditions and local surface chemistry, we are able to minimize depletion limitations and measure apparent adsorption rate constants of three monoclonal antibodies, other proteins and surfactants with a hydrophobic surface. We show that surface adsorption rates scale with the molecular mass of the molecule, with polysorbates therefore showing thousand times slower rates than antibodies. Moreover, we observed that the desorption dynamic of polysorbates from a given hydrophobic surface depends on surface coverage, whereas this is not the case for Poloxamer 188. These novel contributions to surface adsorption dynamics enable a new perspective on the evaluation of drug surface compatibility and can, together with diffusion rates, be used to predict the protective potential of surfactants in given conditions.
Collapse
Affiliation(s)
- Guillaume Lefebvre
- Univ. Grenoble Alpes, CNRS, Grenoble-INP, LMGP, F-38000, Grenoble, France(1); Sanofi, 94400, Vitry-sur-Seine, France
| | - Franz Bruckert
- Univ. Grenoble Alpes, CNRS, Grenoble-INP, LMGP, F-38000, Grenoble, France(1)
| | | | | | | |
Collapse
|
18
|
Hedayati M, Krapf D, Kipper MJ. Dynamics of long-term protein aggregation on low-fouling surfaces. J Colloid Interface Sci 2021; 589:356-366. [PMID: 33482534 DOI: 10.1016/j.jcis.2021.01.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 12/13/2020] [Accepted: 01/01/2021] [Indexed: 01/12/2023]
Abstract
Understanding the mechanisms of protein interactions with solid surfaces is critical to predict how proteins affect the performance of materials in biological environments. Low-fouling and ultra-low fouling surfaces are often evaluated in short-term protein adsorption experiments, where 'short-term' is defined as the time required to reach an initial apparent or pseudo-equilibrium, which is usually less than 600 s. However, it has long been recognized that these short-term observations fail to predict protein adsorption behavior in the long-term, characterized by irreversible accumulation of protein on the surface. This important long-term behavior is frequently ignored or attributed to slow changes in surface chemistry over time-such as oxidation-often with little or no experimental evidence. Here, we report experiments measuring protein adsorption on "low-fouling" and "ultralow-fouling" surfaces using single-molecule localization microscopy to directly probe protein adsorption and desorption. The experiments detect protein adsorption for thousands of seconds, enabling direct observation of both short-term (reversible adsorption) and long-term (irreversible adsorption leading to accumulation) protein-surface interactions. By bridging the gap between these two time scales in a single experiment, this work enables us to develop a single mathematical model that predicts behavior in both temporal regimes. The experimental data in combination with the resulting model provide several important insights: (1) short-term measurements of protein adsorption using ensemble-averaging methods may not be sufficient for designing antifouling materials; (2) all investigated surfaces eventually foul when in long-term contact with protein solutions; (3) fouling can occur through surface-induced oligomerization of proteins which may be a distinct step from irreversible adsorption; and (4) surfaces can be designed to reduce oligomerization or the adsorption of oligomers, to prevent or delay fouling.
Collapse
Affiliation(s)
- Mohammadhasan Hedayati
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | - Diego Krapf
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA; School of Advanced Materials Discovery, Colorado State University, Fort Collins, CO 80523, USA; Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, CO 80523, USA.
| | - Matt J Kipper
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, CO 80523, USA; School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA; School of Advanced Materials Discovery, Colorado State University, Fort Collins, CO 80523, USA.
| |
Collapse
|
19
|
Deng F, Zhai W, Yin Y, Peng C, Ning C. Advanced protein adsorption properties of a novel silicate-based bioceramic: A proteomic analysis. Bioact Mater 2021; 6:208-218. [PMID: 32913929 PMCID: PMC7451930 DOI: 10.1016/j.bioactmat.2020.08.011] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 08/08/2020] [Accepted: 08/12/2020] [Indexed: 12/13/2022] Open
Abstract
Silicate bioceramics have been shown to possess excellent cytocompatibility and osteogenic activity, but the exact mechanism is still unclear. Protein adsorption is the first event taking place at the biomaterial-tissue interface, which is vital to the subsequent cellular behavior and further influence the biomaterial-tissue interaction. In this work, the protein adsorption behavior of a novel CPS bioceramic was evaluated using the proteomics technology. The results showed that CPS adsorbed more amount and types of serum proteins than HA. FN1 and IGF1 proteins selected from proteomics results were validated by Western-blot experiment. Pathway analysis also revealed mechanistic insights how these absorbed proteins by CPS help mediate cell adhesion and promotes osteogenic activity. Firstly, the dramatically enhanced adsorption of FN1 could greatly promote cell adhesion and growth. Secondly, IGF1 was uniquely adsorbed on CPS bioceramic and IGF1 could activate Rap1 signaling pathway to promote cell adhesion. Thirdly, the increased adsorption of FN1, IGF1 and COL1A2 proteins on CPS explains its better ability on bone regeneration than HA. Fourthly, the increased adsorption of IGF1, CHAD, COL2A1 and THBS4 proteins on CPS explains its ability on cartilage formation. Lastly, the increased adsorption of immunological related proteins on CPS may also play a positive role in bone regeneration. In addition, CPS had a much better cell adhesion ability than HA, proving that more adsorbed proteins really had a positive effect on cell behavior. The more adsorbed proteins on CPS than HA might indicated a better bone regeneration rate at early stage of implantation.
Collapse
Affiliation(s)
- Fanyan Deng
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Wanyin Zhai
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Yue Yin
- National Facility for Protein Science in Shanghai, Zhangjiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Science, Shanghai, 201210, China
| | - Chao Peng
- National Facility for Protein Science in Shanghai, Zhangjiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Science, Shanghai, 201210, China
| | - Congqin Ning
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
- The Education Ministry Key Lab of Resource Chemistry and Shanghai Key Laboratory of Rare Earth Functional Materials, Shanghai Normal University, Shanghai, 200234, China
| |
Collapse
|
20
|
Jesmer AH, Wylie RG. Controlling Experimental Parameters to Improve Characterization of Biomaterial Fouling. Front Chem 2020; 8:604236. [PMID: 33363113 PMCID: PMC7759637 DOI: 10.3389/fchem.2020.604236] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 10/30/2020] [Indexed: 12/17/2022] Open
Abstract
Uncontrolled protein adsorption and cell binding to biomaterial surfaces may lead to degradation, implant failure, infection, and deleterious inflammatory and immune responses. The accurate characterization of biofouling is therefore crucial for the optimization of biomaterials and devices that interface with complex biological environments composed of macromolecules, fluids, and cells. Currently, a diverse array of experimental conditions and characterization techniques are utilized, making it difficult to compare reported fouling values between similar or different biomaterials. This review aims to help scientists and engineers appreciate current limitations and conduct fouling experiments to facilitate the comparison of reported values and expedite the development of low-fouling materials. Recent advancements in the understanding of protein-interface interactions and fouling variability due to experiment conditions will be highlighted to discuss protein adsorption and cell adhesion and activation on biomaterial surfaces.
Collapse
Affiliation(s)
| | - Ryan G. Wylie
- Department of Chemistry and Chemical Biology, Hamilton, ON, Canada
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
| |
Collapse
|
21
|
Polycationic condensed tannin/polysaccharide-based polyelectrolyte multilayers prevent microbial adhesion and proliferation. Eur Polym J 2020. [DOI: 10.1016/j.eurpolymj.2020.109677] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
22
|
Hedayati M, Kipper MJ, Krapf D. Anomalous protein kinetics on low-fouling surfaces. Phys Chem Chem Phys 2020; 22:5264-5271. [PMID: 32095800 DOI: 10.1039/d0cp00326c] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this work, protein-surface interactions were probed in terms of adsorption and desorption of a model protein, bovine serum albumin, on a low-fouling surface with single-molecule localization microscopy. Single-molecule experiments enable precise determination of both adsorption and desorption rates. Strikingly the experimental data show anomalous desorption kinetics, evident as a surface dwell time that exhibits a power-law distribution, i.e. a heavy-tailed rather than the expected exponential distribution. As a direct consequence of this heavy-tailed distribution, the average desorption rate depends upon the time scale of the experiment and the protein surface concentration does not reach equilibrium. Further analysis reveals that the observed anomalous desorption emerges due to the reversible formation of a small fraction of soluble protein multimers (small oligomers), such that each one desorbs from the surface with a different rate. The overall kinetics can be described by a series of elementary reactions, yielding simple scaling relations that predict experimental observations. This work reveals a mechanistic origin for anomalous desorption kinetics that can be employed to interpret observations where low-protein fouling surfaces eventually foul when in long-term contact with protein solutions. The work also provides new insights that can be used to define design principles for non-fouling surfaces and to predict their performance.
Collapse
Affiliation(s)
- Mohammadhasan Hedayati
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, CO 80523, USA.
| | - Matt J Kipper
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, CO 80523, USA. and School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA. and School of Advanced Materials Discovery, Colorado State University, Fort Collins, CO 80523, USA
| | - Diego Krapf
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA. and School of Advanced Materials Discovery, Colorado State University, Fort Collins, CO 80523, USA and Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, CO 80523, USA
| |
Collapse
|
23
|
Fractal analysis of the formation process and morphologies of hyaluronan/chitosan nanofilms in layer-by-layer assembly. POLYMER 2020. [DOI: 10.1016/j.polymer.2020.122283] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|