1
|
Ofstead CL, Hopkins KM, Preston AL, James CY, Holdsworth JE, Smart AG, Lamb LA, Love KL. Fluid retention in endoscopes: A real-world study on drying effectiveness. Am J Infect Control 2024; 52:635-643. [PMID: 38408542 DOI: 10.1016/j.ajic.2024.02.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 02/21/2024] [Accepted: 02/22/2024] [Indexed: 02/28/2024]
Abstract
BACKGROUND Outbreaks linked to inadequate endoscope drying have infected numerous patients, and current standards and guidelines recommend at least 10 minutes of forced air for drying channels. This study evaluated a new forced-air drying system (FADS) for endoscopes. METHODS Drying was assessed using droplet detection cards; visual inspection of air/water connectors, suction connectors, and distal ends; and borescope examinations of endoscope interiors. Assessments were performed after automated endoscope reprocessor (AER) alcohol flush and air purge cycles and after 10-minute FADS cycles. RESULTS Researchers evaluated drying during encounters with 22 gastroscopes and 20 colonoscopes. After default AER alcohol and air purge cycles, 100% (42/42) of endoscopes were still wet. Substantial fluid emerged from distal ends during the first 15 seconds of the FADS cycle, and droplets also emerged from air/water and suction connectors. Following FADS cycle completion, 100% (42/42) were dry, with no retained fluid detected by any of the assessment methods. CONCLUSIONS Multiple endoscope ports and channels remained wet after AER cycles intended to aid in drying but were dry after the FADS cycle. This study reinforced the need to evaluate the effectiveness of current drying practices and illustrated the use of practical tools in a real-world setting.
Collapse
Affiliation(s)
- Cori L Ofstead
- Ofstead & Associates, Inc., Research Department, Bloomington, MN.
| | | | - Aaron L Preston
- Emory University Hospital Midtown, Infection Prevention Department, Atlanta, GA
| | - Charesse Y James
- Emory University Hospital Midtown, Endoscopy Department, Atlanta, GA
| | - Jill E Holdsworth
- Emory University Hospital Midtown, Infection Prevention Department, Atlanta, GA
| | - Abigail G Smart
- Ofstead & Associates, Inc., Research Department, Bloomington, MN
| | - Larry A Lamb
- Ofstead & Associates, Inc., Research Department, Bloomington, MN
| | - Kari L Love
- Emory Healthcare, Infection Prevention Department, Atlanta, GA
| |
Collapse
|
2
|
van der Ploeg K, Klaassen CHW, Vos MC, Severin JA, Mason-Slingerland BCGC, Bruno MJ. A search strategy for detecting duodenoscope-associated infections: a retrospective observational study. J Hosp Infect 2024; 147:56-62. [PMID: 38447805 DOI: 10.1016/j.jhin.2024.02.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 02/21/2024] [Accepted: 02/22/2024] [Indexed: 03/08/2024]
Abstract
BACKGROUND Duodenoscope-associated infections (DAIs) are exogenous infections resulting from the use of contaminated duodenoscopes. Though numerous outbreaks of DAI have involved multidrug-resistant micro-organisms (MDROs), outbreaks involving non-MDROs are also likely to occur. Detection challenges arise as these infections often resolve before culture or because causative strains are not retained for comparison with duodenoscope strains. AIM To identify and analyse DAIs spanning a seven-year period in a tertiary care medical centre. METHODS This was a retrospective observational study. Duodenoscope cultures positive for gastrointestinal flora between March 2015 and September 2022 were paired with duodenoscope usage data to identify patients exposed to contaminated duodenoscopes. Analysis encompassed patients treated after a positive duodenoscope culture and those treated within the interval from a negative to a positive culture. Patient identification numbers were cross-referenced with a clinical culture database to identify patients developing infections with matching micro-organisms within one year of their procedure. A 'pair' was established upon a species-level match between duodenoscope and patient cultures. Pairs were further analysed via antibiogram comparison, and by whole-genome sequencing (WGS) to determine genetic relatedness. FINDINGS Sixty-eight pairs were identified; of these, 21 exhibited matching antibiograms which underwent WGS, uncovering two genetically closely related pairs categorized as DAIs. Infection onset occurred up to two months post procedure. Both causative agents were non-MDROs. CONCLUSION This study provides crucial insights into DAIs caused by non-MDROs and it highlights the challenge of DAI recognition in daily practice. Importantly, the delayed manifestation of the described DAIs suggests a current underestimation of DAI risk.
Collapse
Affiliation(s)
- K van der Ploeg
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, The Netherlands; Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - C H W Klaassen
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - M C Vos
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - J A Severin
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - B C G C Mason-Slingerland
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - M J Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, The Netherlands.
| |
Collapse
|
3
|
Garcia NB, Oliveira AC. Endoscope channel drying, storage, and conditions after reprocessing: How safe are they in clinical practice? REVISTA DE GASTROENTEROLOGIA DE MEXICO (ENGLISH) 2024:S2255-534X(24)00031-8. [PMID: 38644085 DOI: 10.1016/j.rgmxen.2023.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Accepted: 06/25/2023] [Indexed: 04/23/2024]
Abstract
INTRODUCTION AND AIMS Adequate drying and proper storage of flexible endoscopes are essential for maintaining quality in their reprocessing. The aim of the present study was to evaluate the drying stages, storage, and channel conditions of endoscopes through borescope inspection. MATERIAL AND METHODS The personnel responsible for endoscope reprocessing were interviewed. Storage conditions at 10 endoscopy facilities were inspected and an internal examination of the channels and ports of the stored equipment was carried out, utilizing a borescope. A total of 74 stored endoscope channels were evaluated. RESULTS Only 10% of the facilities inspected utilized transport cases for storage and only 10% had rooms exclusively used for storage. Sixty percent of the facilities did not perform any shelf-life control. All the channels evaluated were scratched and fluids were present on 69% of them. CONCLUSIONS Endoscope reprocessing can be improved through the implementation of drying and storage control and validation tools, as well as the use of borescopes and periodic clinical audits.
Collapse
Affiliation(s)
- N B Garcia
- Escuela de Enfermería, Universidad Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil.
| | - A C Oliveira
- Escuela de Enfermería, Universidad Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| |
Collapse
|
4
|
Chang WK, Peng CL, Chen YW, Sun CK, Chen CC, Liu TC, Chu YY, Tsai IF, Chung CS, Lin HF, Hsu FY, Tai WC, Lee HC, Yen HH, Wang EM, Chen SH, Chu CH, Chen MJ, Lu CL, Chiu CT. Recommendations and guidelines for endoscope reprocessing: Current position statement of digestive endoscopic society of Taiwan. JOURNAL OF MICROBIOLOGY, IMMUNOLOGY, AND INFECTION = WEI MIAN YU GAN RAN ZA ZHI 2024; 57:211-224. [PMID: 38135645 DOI: 10.1016/j.jmii.2023.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 10/23/2023] [Accepted: 12/07/2023] [Indexed: 12/24/2023]
Abstract
Reprocessing of gastrointestinal (GI) endoscopes and accessories is an essential part of patient safety and quality control in GI endoscopy centers. However, current endoscopic reprocessing guidelines or procedures are not adequate to ensure patient-safe endoscopy. Approximately 5.4 % of the clinically used duodenoscopes remain contaminated with high-concern microorganisms. Thus, the Digestive Endoscopy Society of Taiwan (DEST) sets standards for the reprocessing of GI endoscopes and accessories in endoscopy centers. DEST organized a task force working group using the guideline-revision process. These guidelines contain principles and instructions of step-by-step for endoscope reprocessing. The updated guidelines were established after a thorough review of the existing global and local guidelines, systematic reviews, and health technology assessments of clinical effectiveness. This guideline aims to provide detailed recommendations for endoscope reprocessing to ensure adequate quality control in endoscopy centers.
Collapse
Affiliation(s)
- Wei-Kuo Chang
- Division of Gastroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan
| | - Chen-Ling Peng
- Department of Integrated Diagnostics & Therapeutics, National Taiwan University Hospital, National Taiwan University College of Medicine, Taiwan
| | - Yen-Wei Chen
- Endoscopy Center for Diagnosis and Treatment, Taipei Veterans General Hospital, Taiwan
| | - Cheuk-Kay Sun
- Division of Hepatology and Gastroenterology, Department of Internal Medicine, Shin Kong Wu Ho-Su Memorial Hospital, Taipei 11101, Taiwan
| | - Chieh-Chang Chen
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, National Taiwan University Hospital, Taiwan
| | - Tao-Chieh Liu
- Division of Gastroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan
| | - Yin-Yi Chu
- Department of Gastroenterology and Hepatology, New Taipei Municipal Tucheng Hospital, Chang Gung University, Taoyuan, Taiwan
| | - I-Fang Tsai
- Ultrasonography and Endoscopy Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Chen-Shuan Chung
- Ultrasonography and Endoscopy Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Hsiao-Fen Lin
- Division of Gastroenterology and Hepatology, Renai Branch, Taipei City Hospital, Taiwan
| | - Fang-Yu Hsu
- Therapeutic Endoscopic Center, Department of Gastroenterology and Hepatology, Linkou Chang Gung Memorial Hospital, Taiwan
| | - Wei-Chen Tai
- Division of Hepato-Gastroenterology, Department of Internal Medicine, Chang Gung Memorial Hospital, Kaohsiung, Taiwan
| | - Hsi-Chang Lee
- Division of Gastroenterology and Hepatology, Renai Branch, Taipei City Hospital, Taiwan
| | - Hsu-Heng Yen
- Division of Gastroenterology, Changhua Christian Hospital, Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taiwan
| | - E-Ming Wang
- Department of Internal Medicine Division of Gastroenterology and Hepatology, Kaohsiung Veterans General Hospital, Taiwan
| | - Shu-Hui Chen
- Division of Gastroenterology, Changhua Christian Hospital, Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taiwan
| | - Cheng-Hsin Chu
- Division of Gastroenterology, Internal Medicine, MacKay Memorial Hospital, Taiwan
| | - Ming-Jen Chen
- Division of Gastroenterology, Internal Medicine, MacKay Memorial Hospital, Taiwan
| | - Ching-Liang Lu
- Endoscopy Center for Diagnosis and Treatment, Taipei Veterans General Hospital, Taiwan
| | - Cheng-Tang Chiu
- Department of Gastroenterology & Hepatology, Linkou Chang Gung Memorial Hospital, Chang Gung Medical Foundation, Taiwan.
| |
Collapse
|
5
|
Chen H, Liu J, Zeng A, Qin N. Analysis of sterilization efficiency and application cost of three low temperature sterilization methods. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:045112. [PMID: 38597749 DOI: 10.1063/5.0175121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 03/24/2024] [Indexed: 04/11/2024]
Abstract
OBJECTIVE This paper discusses the sterilization efficiency of three low temperature sterilization methods used in thermosensitive medical devices and makes a preliminary analysis of sterilization costs so as to provide the basis for reasonable selection of low temperature sterilizer in Central Sterile Supply Department. METHODS Medical devices compatible with the three sterilization methods were selected for sterilization, and two packaging materials were selected for the three low-temperature sterilization equipment according to the compatibility of the packaging materials. The equipment packed with the same packaging materials were sterilized for five times, and each low-temperature sterilizer was sterilized for a total of ten times. The sterilization effect, sterilization cycle time, energy consumption, and cost of the three sterilizers were compared. RESULTS The cycle time of ethylene oxide sterilizer was 393.6 min, and the cycle time of hydrogen peroxide low temperature plasma sterilizer was 56.1 min. The cycle time of low temperature steam and formaldehyde sterilizer was 105.7 min. The hydrogen peroxide low temperature plasma sterilizes single cycle power consumption at a maximum of 5 kWh. The single cycle energy consumption of compressed air ethylene oxide sterilizer is up to 12 l. In terms of sterilization application cost, hydrogen peroxide low temperature plasma sterilization has the highest cost, followed by ethylene oxide sterilization, and low temperature steam and formaldehyde sterilization is the lowest. CONCLUSION The sterilization efficiency of hydrogen peroxide low temperature plasma sterilization is the highest, followed by low temperature steam and formaldehyde sterilization, and the lowest is ethylene oxide sterilization. The three low temperature sterilization methods can achieve effective sterilization of devices. Each hospital can choose an appropriate low temperature sterilization method according to the characteristics of thermosensitive instruments, turnover efficiency requirements, and financial status.
Collapse
Affiliation(s)
- Hui Chen
- West China Hospital/West China School of Nursing, Sichuan University, Guoxuexiang No. 37, Chengdu, Sichuan, China
| | - Jiawei Liu
- West China Hospital/West China School of Nursing, Sichuan University, Guoxuexiang No. 37, Chengdu, Sichuan, China
| | - Aiying Zeng
- West China Hospital/West China School of Nursing, Sichuan University, Guoxuexiang No. 37, Chengdu, Sichuan, China
| | - Nian Qin
- West China Hospital/West China School of Nursing, Sichuan University, Guoxuexiang No. 37, Chengdu, Sichuan, China
| |
Collapse
|
6
|
Hopkins KM, Adams SJ, Lamb LA, Smart AG, Ofstead CL. Beyond Endoscopes: Pilot Study of Surgical Instrument Lumen Inspection. Biomed Instrum Technol 2024; 58:25-33. [PMID: 38377297 PMCID: PMC10878677 DOI: 10.2345/0899-8205-58.1.25] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2024]
Abstract
Objective: Borescope examinations of endoscope channels are commonly described in literature, but no studies on surgical instrument lumen inspection have been published recently. Inadequately processed surgical instruments have been implicated in patient infections. This study assessed the utility of borescopes for inspecting surgical instruments. Methods: The study team inspected and photographed sterilized, patient-ready arthroscopic shaver handpieces and suction tips using a tablet camera and borescopes to characterize internal anatomy, defects found in lumens, and the impact of recleaning on debris or residues. Results: Ten suctions and eight shavers were inspected. All suctions had internal ridges and suction holes that were perpendicular to the lumen. All shavers had visible ridges, elbows, and lever mechanisms inside lumens. Of the 18 instruments, 16 (88%) had internal features that appeared rough or jagged and 17 (94%) had visible debris or discoloration in the lumens. Recleaning efforts generally were effective for suctions, but multiple rounds of recleaning with enhanced steps were less effective for shavers, which were replaced. Researchers documented retained soil and brush bristles in several new shavers despite following manufacturer instructions for cleaning and found visible damage and discoloration within five uses. Discussion: This study demonstrated the value of borescope examinations for surgical instrument lumens. Visual inspections identified anatomical features that could influence cleaning effectiveness and detected residual soil, discoloration, and debris in most instruments. The findings suggested that manufacturer cleaning instructions were insufficient and additional cleaning was not always effective. In response, the site's multidisciplinary team strengthened risk assessment protocols and enhanced their cleaning practices.
Collapse
|
7
|
Cheng SH, Lin YT, Lu HT, Tsuei YC, Chu W, Chu WC. The Evolution of Spinal Endoscopy: Design and Image Analysis of a Single-Use Digital Endoscope Versus Traditional Optic Endoscope. Bioengineering (Basel) 2024; 11:99. [PMID: 38275579 PMCID: PMC10813680 DOI: 10.3390/bioengineering11010099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/11/2024] [Accepted: 01/17/2024] [Indexed: 01/27/2024] Open
Abstract
Spinal endoscopy has evolved significantly since its inception, offering minimally invasive solutions for various spinal pathologies. This study introduces a promising innovation in spinal endoscopy-a single-use digital endoscope designed to overcome the drawbacks of traditional optic endoscopes. Traditional endoscopes, despite their utility, present challenges such as fragility, complex disinfection processes, weight issues, and susceptibility to mechanical malfunctions. The digital endoscope, with its disposable nature, lighter weight, and improved image quality, aims to enhance surgical procedures and patient safety. The digital endoscope system comprises a 30-degree 1000 × 1000 pixel resolution camera sensor with a 4.3 mm working channel, and LED light sources replacing optical fibers. The all-in-one touch screen tablet serves as the host computer, providing portability and simplified operation. Image comparisons between the digital and optic endoscopes revealed advantages in the form of increased field of view, lesser distortion, greater close-range resolution, and enhanced luminance. The single-use digital endoscope demonstrates great potential for revolutionizing spine endoscopic surgeries, offering convenience, safety, and superior imaging capabilities compared to traditional optic endoscopes.
Collapse
Affiliation(s)
- Shih-Hao Cheng
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
- Department of Orthopedics, Cheng Hsin General Hospital, Taipei 11221, Taiwan
| | - Yen-Tsung Lin
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
| | - Hsin-Tzu Lu
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
| | - Yu-Chuan Tsuei
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
- Department of Orthopedics, Cheng Hsin General Hospital, Taipei 11221, Taiwan
| | - William Chu
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
- Department of Orthopedics, Cheng Hsin General Hospital, Taipei 11221, Taiwan
- School of Nursing, National Taipei University of Nursing and Health Sciences, Taipei 11221, Taiwan
| | - Woei-Chyn Chu
- Institute of Biomedical Engineering, National Yang-Ming Chiao-Tung University, Taipei 11221, Taiwan; (S.-H.C.); (Y.-T.L.); (Y.-C.T.)
| |
Collapse
|
8
|
Croke L. Guideline for Manual High-Level Disinfection. AORN J 2023; 118:P4-P6. [PMID: 37750795 DOI: 10.1002/aorn.14014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
|
9
|
Mallard TS, Roswell SS, Sylvester EP, Ofstead CL, Scanlan JM, Brandabur JJ, Ramakrishnan AV. A water-soluble alternative to simethicone for gastrointestinal endoscopy: Results of a clinical trial. Am J Infect Control 2023; 51:1192-1195. [PMID: 37105357 DOI: 10.1016/j.ajic.2023.04.166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/14/2023] [Accepted: 04/15/2023] [Indexed: 04/29/2023]
Abstract
During endoscopy, simethicone defoaming agents are commonly used to improve visualization, but they leave residues and impact drying. This clinical trial involved patients undergoing colonoscopy procedures with substantial bubbles that impeded mucosal wall visibility. As an alternative to simethicone, investigators evaluated a water-soluble, ginger-based gastrointestinal supplement (GI-Ease) that did not contain sugars, thickeners, or binding agents. In 112/114 cases (98%), the bubbles were reduced sufficiently to allow visualization of the gastrointestinal tract, with no adverse events.
Collapse
Affiliation(s)
- Teri S Mallard
- Providence Swedish Medical Center, Endoscopy, Seattle, WA.
| | | | | | | | - James M Scanlan
- Providence HRA, Providence Health and Services, Seattle, Washington; Swedish Center for Research and Innovation, Swedish Medical Center Seattle, Seattle, Washington
| | | | | |
Collapse
|
10
|
Speth J. Guidelines in Practice: Processing Flexible Endoscopes. AORN J 2023; 118:169-178. [PMID: 37624056 DOI: 10.1002/aorn.13982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 04/12/2023] [Indexed: 08/26/2023]
Abstract
Flexible endoscopes allow surgeons and proceduralists to view patients' internal organs through small incisions or natural orifices. These devices may be difficult to clean and dry adequately, and the formation of biofilm can further complicate effective cleaning. The updated AORN "Guideline for processing flexible endoscopes" provides perioperative personnel with evidence-based best practice recommendations on a variety of concepts associated with this topic. This article provides an overview of the guideline and discusses recommendations for point-of-use treatment, transport, cleaning (including verification and drying), and storage of flexible endoscopes. It also includes a scenario that illustrates the importance of adequately drying and storing flexible endoscopes. When processing flexible endoscopes, personnel should adhere to the endoscope and processing equipment manufacturers' instructions for use. Perioperative nurses should review the guideline in its entirety and implement recommendations in practice settings where flexible endoscopes are used.
Collapse
|
11
|
Nerandzic M, Antloga K, Robinson N. Alcohol flush does not aid in endoscope channel drying but may serve as an adjunctive microbiocidal measure: A new take on an old assumption. Am J Infect Control 2023; 51:772-778. [PMID: 36130627 DOI: 10.1016/j.ajic.2022.09.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 09/02/2022] [Accepted: 09/12/2022] [Indexed: 11/01/2022]
Abstract
BACKGROUND Alcohol is perceived to aid flexible endoscope channel drying, however we previously showed alcohol increased the time required to dry some channels with forced air versus water alone. Yet, alcohol may prevent microorganism outgrowth during storage. Drying endoscope channels has been shown to prevent outgrowth, but it is unknown if incomplete drying (<10 µL remaining) provides similar protection. METHODS Endoscope channel test articles were used to determine the efficacy of 70%-30% alcohol flush for prevention of Pseudomonas aeruginosa outgrowth and drying efficiency. For non-alcohol flushed channels, the impact of forced air drying on outgrowth of P. aeruginosa was determined. RESULTS Alcohol flush (70%-30%) prevented outgrowth with little to no recovery of P. aeruginosa during ambient storage. 70% alcohol increased channel drying time by 1.5 or 3-fold compared to 50% alcohol or water, respectively. Forced air drying of non-alcohol flushed channels greatly reduced the initial contamination level and prevented outgrowth. Incomplete drying of contaminated channels was akin to no application of forced air. Applying forced air for more time than necessary to remove residual liquid did not completely eliminate the low level recovery of P. aeruginosa. CONCLUSIONS Flushing with reduced concentrations of alcohol may provide a strategy to prevent microbial outgrowth while reducing drying time.
Collapse
|
12
|
Yassin M, Clifford A, Dixon H, Donskey CJ. How effective are the alcohol flush and drying cycles of automated endoscope reprocessors? Stripped endoscope model. Am J Infect Control 2023; 51:527-532. [PMID: 36842713 DOI: 10.1016/j.ajic.2023.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 02/12/2023] [Accepted: 02/13/2023] [Indexed: 02/27/2023]
Abstract
BACKGROUND Effective drying of the internal channels of endoscopes is essential to prevent the growth of water-borne pathogens and to assure adequate sterilization with vaporized hydrogen peroxide or ethylene oxide. The aim of this study was to evaluate the dryness of endoscopes after a routine disinfection process in an automated endoscope reprocessor. METHODS Stripped endoscopes (SE) that allow for visual inspection of the inside channels were reprocessed per protocol in a large urban medical center, with a 3-minute or 10-minute air flush following reprocessing. SE was hung and observed for any water within the channels after reprocessing and after a week of ambient storage. Ready-for-use endoscopes were also randomly spot-checked for moisture visually and with moisture detection paper. RESULTS All SE were grossly wet after HLD with a 3-minute air flush, despite alcohol flush and drying cycle. The 10-minute air flush was effective at drying the biopsy/suction channel, but not the air/water channels. Hanging had limited effect, being most effective in the biopsy/suction channels. Of the 77 ready-for-use respiratory and gastrointestinal endoscopes assessed, 37 (48.1%) showed evidence of retained moisture. CONCLUSIONS Air flush cycles commonly used in the final steps of automated endoscope reprocessing may not adequately dry endoscope channels, particularly the narrower diameter air/water channels. An extended 10-minute air flush appears effective at drying the larger biopsy/suction channel, but has limited effect on the air/water channels.
Collapse
Affiliation(s)
- Mohamed Yassin
- University of Pittsburgh School of Medicine & Public Health, Pittsburgh, PA; Infection Prevention Department University of Pittsburgh Medical Center Mercy, Pittsburgh, PA.
| | - Adrian Clifford
- University of Pittsburgh School of Public Health, Pittsburgh, PA
| | - Heather Dixon
- Infection Prevention Department University of Pittsburgh Medical Center Mercy, Pittsburgh, PA; University of Pittsburgh School of Public Health, Pittsburgh, PA
| | - Curtis J Donskey
- Infectious Diseases Section, Louis Stokes Cleveland VA Medical Center, Cleveland, OH
| |
Collapse
|
13
|
Shang R, Liu J, Luo Z, Huang X, Zhang C, Chen D, Wu L, Yao L, Wang X, Wang Q, Wu Y, Zhang L, Yu H. Effect of an automated flexible endoscope channel brushing system on improving reprocessing quality: a randomized controlled study. Endoscopy 2023. [PMID: 36623838 DOI: 10.1055/a-2009-4735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
BACKGROUND Qualified reprocessing, of which meticulous channel brushing is the most crucial step, is essential for prevention and control of endoscopy-associated infections. However, channel brushing is often omitted in practice. This study aimed to evaluate the effect of an automated flexible endoscope channel brushing system (AECBS) on improving the quality of endoscope reprocessing. METHODS This prospective, randomized controlled study was conducted between 24 November 2021 and 22 January 2022 at Renmin Hospital of Wuhan University, China. Eligible endoscopes were randomly allocated to the auto group (channels brushed by AECBS) or the manual group (channels brushed manually), with sampling and culturing after high-level disinfection and drying. The primary end point was the proportion of endoscopes with positive cultures. RESULTS 204 endoscopes in the auto group and 205 in the manual group were analyzed. The proportion of endoscopes with positive cultures was significantly lower in the auto group (15.2 % [95 %CI 10.7 %-21.0 %]) than in the manual group (23.4 % [95 %CI 17.9 %-29.9 %]). CONCLUSIONS AECBS could effectively reduce bioburden and improve reprocessing quality of gastroscopes and colonoscopes. AECBS has the potential to replace manual brushing and lower the risk of endoscopy-associated infections, providing a new option for the optimization of reprocessing.
Collapse
Affiliation(s)
- Renduo Shang
- Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China.,Key Laboratory of Hubei Province for Digestive System Disease, Renmin Hospital of Wuhan University, Wuhan, China.,Hubei Provincial Clinical Research Center for Digestive Disease Minimally Invasive Incision, Renmin Hospital of Wuhan University, Wuhan, China
| | - Jun Liu
- Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China.,Department of Nursing, Renmin Hospital of Wuhan University, Wuhan, China
| | - Zi Luo
- Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Xingmin Huang
- Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Caiqing Zhang
- Department of Laboratory Science, Renmin Hospital of Wuhan University, Wuhan, China
| | - Di Chen
- Key Laboratory of Hubei Province for Digestive System Disease, Renmin Hospital of Wuhan University, Wuhan, China
| | - Lianlian Wu
- Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Liwen Yao
- Hubei Provincial Clinical Research Center for Digestive Disease Minimally Invasive Incision, Renmin Hospital of Wuhan University, Wuhan, China
| | - Xianglan Wang
- Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Qing Wang
- Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Yunxing Wu
- Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Lili Zhang
- Department of Nursing, Renmin Hospital of Wuhan University, Wuhan, China
| | - Honggang Yu
- Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China.,Key Laboratory of Hubei Province for Digestive System Disease, Renmin Hospital of Wuhan University, Wuhan, China.,Hubei Provincial Clinical Research Center for Digestive Disease Minimally Invasive Incision, Renmin Hospital of Wuhan University, Wuhan, China
| |
Collapse
|
14
|
Kwakman JA, Vos MC, Bruno MJ. Higher yield in duodenoscope cultures collected with addition of neutralizing agent. J Hosp Infect 2023; 132:28-35. [PMID: 36414167 DOI: 10.1016/j.jhin.2022.11.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 10/21/2022] [Accepted: 11/12/2022] [Indexed: 11/21/2022]
Abstract
AIM Microbiological cultures are the gold standard in the monitoring of duodenoscope reprocessing. However, many different sampling and culturing techniques are used, making it difficult to compare results. The latest Centers for Disease Control and Prevention protocol advises the use of a neutralizer to deactivate any remaining disinfectants in the samples. This study compared culturing results of duodenoscope samples collected with and without addition of a neutralizer. METHODS Six duodenoscopes were soiled with gut bacteria in a non-clinical experimental setting and reprocessed afterwards. Samples of the tip and working channel were collected immediately after decontamination or after drying. Dey-Engley (DE) broth was added as a neutralizer to the samples of four duodenoscopes; samples for the other two duodenoscopes were collected without the addition of DE broth. RESULTS Post-decontamination cultures were significantly more likely to be positive for growth of the applied micro-organisms in the group of samples with DE broth (88.1% vs 20.2%; P<0.0001). Post-drying samples were significantly more likely to be positive in the group of samples without DE broth (75.7% vs 33.4%; P<0.001). CONCLUSION The addition of DE broth to samples collected from wet duodenoscopes increases the yield of those cultures. Remaining disinfectants in wet duodenoscopes can lead to false-negative results. This can be overcome by adding a neutralizer, such as DE broth, to the samples. The higher yield after drying in the group without neutralizer could be due to biofilm formation in these two duodenoscopes, but this was not investigated. Standardization of the sampling method can help to compare both clinical and study results regarding duodenoscope contamination.
Collapse
Affiliation(s)
- J A Kwakman
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, the Netherlands; Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, the Netherlands.
| | - M C Vos
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, the Netherlands
| | - M J Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, the Netherlands
| |
Collapse
|
15
|
Speer T, Vickery K, Alfa M, Sáenz R. Minimizing the Risks of Simethicone in Endoscope Reprocessing. J Clin Gastroenterol 2023; 57:153-158. [PMID: 36508253 DOI: 10.1097/mcg.0000000000001807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 10/14/2022] [Indexed: 01/05/2023]
Abstract
This statement was written under the auspices of the World Gastroenterology Organization's Guidelines Committee. The authors are members of the Review Team of the WGO Endoscope Disinfection Guideline and have experience in endoscopy, endoscope reprocessing, and microbiology, including biofilms. During the preparation of the WGO Update on Endoscope Disinfection Guidelines, concerns about simethicone on endoscope channel surfaces compromising cleaning and disinfection were raised. Publications on simethicone, including modes of delivery, effectiveness, and risks, have been reviewed. The paper was written as a companion to the new guidelines with a focus on minimizing the risks of simethicone in endoscope reprocessing.
Collapse
Affiliation(s)
- Tony Speer
- The Royal Melbourne Hospital, Melbourne, Australia
| | | | | | - Roque Sáenz
- Facultad de Medicina, Universidad del Desarrollo, Clinica Alemana de Santiago, Santiago, Chile
| |
Collapse
|
16
|
Investigation of the Internal Conditions of 213 Reprocessed Endoscopic Channels. SURGICAL LAPAROSCOPY, ENDOSCOPY & PERCUTANEOUS TECHNIQUES 2023; 33:4-11. [PMID: 36633916 DOI: 10.1097/sle.0000000000001141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 11/22/2022] [Indexed: 01/13/2023]
Abstract
BACKGROUND AND AIMS Studies have indicated that endoscope reprocessing failure might be attributed to internal damage or residual liquid in endoscopes. However, large-sample survey data on the internal conditions of endoscopic channels after reprocessing are lacking. This study used a borescope to investigate the internal cleanliness and damage of 213 endoscopic biopsy channels after reprocessing at the endoscopy center of the First Affiliated Hospital of Nanchang University, provided in theoretical basis for the efficacy of endoscope reprocessing and maintenance. METHODS A borescope was used to observe and analyze the inside of the endoscopic biopsy channel of 213 reprocessed endoscopes (in accordance with the Chinese health industry standard "Regulation for cleaning and disinfection technique of flexible endoscope (WS 507-2016). Each endoscope was observed for at least 10 minutes, and the results were recorded and evaluated by 5 researchers independently. RESULTS In all, 2504 images and 109 videos were recorded, and abnormal findings were classified into 10 categories: scratches (91.5%, 195/213), scratches with adherent peel (46.0%, 98/213), discolored areas (49.3%, 105/213), transparent drops (28.2%, 60/213), milky drops (23.9%, 51/213), white particles (46.9%, 100/213), attached materials (37.6%, 80/213), wear on metal parts (41.3%, 88/213), rust (23.9%, 51/213), and black spots (35.7%, 76/213). Among scratches, those in Teflon from 0-10 cm at the apex of the biopsy channel outlet and in metal from 0-5 cm at the biopsy channel inlet accounted for 58.4% (114/195) and 96.4% (188/195), respectively. CONCLUSIONS Scratches were the most common form of damage in the endoscopic biopsy channels investigated and were related to the use of endoscopic accessories and cleaning brush materials. The incidence of other abnormalities gradually increased with the duration of use and began to increase significantly after 18 months. All abnormalities have a certain impact on the quality of endoscope reprocessing. We recommend that a borescope be used to check the inside of endoscopic biopsy channels regularly to determine the damage and cleaning conditions and that these channels be reprocessed, repaired, or replaced in a timely manner.
Collapse
|
17
|
WGO Guideline-Endoscope Disinfection Update. J Clin Gastroenterol 2023; 57:1-9. [PMID: 36084165 DOI: 10.1097/mcg.0000000000001759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 06/23/2022] [Indexed: 12/14/2022]
|
18
|
Ofstead CL, Smart AG, Hopkins KM, Wetzler HP. The utility of lighted magnification and borescopes for visual inspection of flexible endoscopes. Am J Infect Control 2023; 51:2-10. [PMID: 36075293 DOI: 10.1016/j.ajic.2022.08.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 08/26/2022] [Accepted: 08/28/2022] [Indexed: 02/05/2023]
Abstract
INTRODUCTION Infections have been linked to damaged or contaminated endoscopes with visible defects. Endoscope processing standards and guidelines state endoscopes should be visually inspected every time they are used. This study evaluated a new visual inspection program using magnification and borescopes in an endoscopy department that had not previously utilized these tools. METHODS Site personnel were given visual inspection tools and training before systematically examining fully processed endoscopes twice during a 2-month period. A risk assessment protocol was used to determine whether endoscopes required recleaning, repair, or other action. Findings were documented using log sheets, photographs, and videotapes. RESULTS Visible damage and residue or debris were observed in 100% of 25 endoscopes at both assessments, and 76% required repair. Defects at baseline included scratches (88%); channel shredding or peeling (80%); adhesive band disintegration (80%); residual soil or debris (white 84%; black 68%; brown 40%; yellow/green 36%; and orange/red 8%); retained fluid (52%); and dents (40%). Findings were similar at follow-up. DISCUSSION/CONCLUSIONS Visual inspection with magnification and borescopes identified actionable defects that could interfere with processing effectiveness in 100% of endoscopes. Infection preventionists have a critical role to play in supporting processing personnel now that standards, guidelines, and manufacturer instructions recommend enhanced visual inspection of every endoscope, every time.
Collapse
|
19
|
Infection control in the bronchoscopy suite: effective reprocessing and disinfection of reusable bronchoscopes. Curr Opin Pulm Med 2023; 29:21-28. [PMID: 36354125 DOI: 10.1097/mcp.0000000000000925] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE OF REVIEW With advancements in technology, flexible bronchoscopes have become thinner in diameter and in need of more thorough reprocessing to prevent infection transmission than ever before. Many experienced bronchoscopists are not aware of the critical steps involved in effective bronchoscope reprocessing and we hope to bridge this gap by describing this process in detail. RECENT FINDINGS Bronchoscope reprocessing includes several distinct steps (precleaning, leak testing, manual cleaning, visual inspection, terminal reprocessing, rinsing and drying). Each step is comprehensive and needs to be carried out systematically by trained personnel. Failure of any step can lead to serious downstream events such as outbreaks and pseudo-outbreaks. Some experts now recommend sterilization when feasible, although high-level disinfection remains the minimum standard. We also will review some literature on the utility of borescopes, automated endoscope reprocessors and disposable bronchoscopes. SUMMARY Our article will focus on the most recent recommendations for effective reprocessing and disinfection of reusable bronchoscopes.
Collapse
|
20
|
Patel P, Chen CH. Colon mucosal injury caused by water jet malfunction during a screening colonoscopy: A case report. World J Clin Cases 2022; 10:12375-12379. [PMID: 36483814 PMCID: PMC9724532 DOI: 10.12998/wjcc.v10.i33.12375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 10/20/2022] [Accepted: 10/26/2022] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Screening colonoscopies are routinely performed and have low occurrences of adverse events such as perforation, bleeding, infection, and post-polypectomy syndrome. True device related adverse events are rarely reported in the literature.
CASE SUMMARY We report a case of a 51-year-old patient without past medical history who presented for her first screening colonoscopy. The patient was thought to have friable mucosa in the cecum and oozed upon water irrigation during screening colonoscopy. It was later identified that the colonoscope used during the index procedure had malfunctioned and produced a pin-point water jet which damaged the colon mucosa of cecum. The maintenance service identified a piece of rubber fragment lodged in the instrument component at the tip of the scope, resulting in high pressure water jet. Repeat colonoscopy with a functioning colonoscope confirmed normal colon mucosa without friability.
CONCLUSION This is the first report of mucosa injury from a colonoscope water jet malfunction. Endoscopists should recognize the potential for endoscopic malfunction.
Collapse
Affiliation(s)
- Parth Patel
- Division of Gastroenterology, Department of Internal Medicine, Washington University School of Medicine, St. Louis, MO 63110, United States
| | - Chien-Huan Chen
- Division of Gastroenterology, Department of Internal Medicine, Washington University School of Medicine, St. Louis, MO 63110, United States
| |
Collapse
|
21
|
Wood A. Clinical Issues-November 2022. AORN J 2022; 116:462-469. [PMID: 36301070 DOI: 10.1002/aorn.13811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 06/30/2022] [Indexed: 11/07/2022]
Abstract
Reuse of single-use bronchoscopes Key words: single use, bronchoscope, contamination, time limit, instructions for use (IFU). Endoscope processing room workflow Key words: one-room design, decontamination sink, droplets, clean storage, transport. Simethicone use during endoscopy Key words: adenosine triphosphate (ATP) testing, defoaming agent, water bottle, borescope inspection, residue. Implementing borescope inspection of flexible endoscopes Key words: visual inspection, cleaning verification, high-risk endoscopes, competency verification, prepurchase evaluation.
Collapse
|
22
|
Tuvo B, Scarpaci M, Cosci T, Ribechini A, Briani S, Luchini G, Totaro M, Baggiani A, Cristina ML, Barnini S, Leonetti S, Casini B. Adoption of Improved Reprocessing Decreased Microbiological Non-Compliance for Bronchoscopes. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:13978. [PMID: 36360859 PMCID: PMC9656596 DOI: 10.3390/ijerph192113978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 10/12/2022] [Accepted: 10/24/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND In the past few decades, the inadequate reprocessing of bronchoscopes has been associated with several serious outbreaks caused by multidrug-resistant microorganisms. In this study we evaluated the improvement in the quality of reprocessing in a Bronchoscopy Unit (BU), after the introduction of a new procedure. METHODS In 2019, observational and clinical audits were conducted in the BU. After the introduction of an improved procedure in 2020, a microbiological surveillance plan was implemented in 2021. RESULTS In 2019, 13 of 22 bronchoscopes (59%) resulted as non-compliant, 18% as high concern organisms (HCO) and 36.4% as high microbial count (≥100 CFU/all channels) and HCO. The most frequent microorganisms were Staphylococcus aureus (38.5%) and NDM-producing Klebsiella pneumoniae (15.4%). The bronchoscopes were stored inside their transport cases, which in some cases were found to be contaminated by the same strains isolated on the bronchoscopes (Enterobacter gergoviae and Vibrio alginolyticus). In 2021, all 31 bronchoscopes were sampled at least three times and 13/99 (13.1%) resulted as non-compliant, mostly K. pneumoniae (4.04%). Contamination level increases weakly in bronchoscopes in use for more than 14 years (R = 0.32). CONCLUSIONS The adoption of an improved reprocessing procedure decreased the non-compliance of bronchoscopes, increasing the quality of the process and patient safety.
Collapse
Affiliation(s)
- Benedetta Tuvo
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Michela Scarpaci
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Tommaso Cosci
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | | | - Silvia Briani
- Hospital Management, University Hospital of Pisa, 56126 Pisa, Italy
| | - Grazia Luchini
- Hospital Management, University Hospital of Pisa, 56126 Pisa, Italy
| | - Michele Totaro
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Angelo Baggiani
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Maria Luisa Cristina
- Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy
| | - Simona Barnini
- Microbiology Unit, University Hospital of Pisa, 56126 Pisa, Italy
| | - Simone Leonetti
- Department of Life Science, School of Advanced Studies Sant’Anna, 56124 Pisa, Italy
| | - Beatrice Casini
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| |
Collapse
|
23
|
Rodríguez de Santiago E, Dinis-Ribeiro M, Pohl H, Agrawal D, Arvanitakis M, Baddeley R, Bak E, Bhandari P, Bretthauer M, Burga P, Donnelly L, Eickhoff A, Hayee B, Kaminski MF, Karlović K, Lorenzo-Zúñiga V, Pellisé M, Pioche M, Siau K, Siersema PD, Stableforth W, Tham TC, Triantafyllou K, Tringali A, Veitch A, Voiosu AM, Webster GJ, Vienne A, Beilenhoff U, Bisschops R, Hassan C, Gralnek IM, Messmann H. Reducing the environmental footprint of gastrointestinal endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) and European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA) Position Statement. Endoscopy 2022; 54:797-826. [PMID: 35803275 DOI: 10.1055/a-1859-3726] [Citation(s) in RCA: 64] [Impact Index Per Article: 32.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Climate change and the destruction of ecosystems by human activities are among the greatest challenges of the 21st century and require urgent action. Health care activities significantly contribute to the emission of greenhouse gases and waste production, with gastrointestinal (GI) endoscopy being one of the largest contributors. This Position Statement aims to raise awareness of the ecological footprint of GI endoscopy and provides guidance to reduce its environmental impact. The European Society of Gastrointestinal Endoscopy (ESGE) and the European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA) outline suggestions and recommendations for health care providers, patients, governments, and industry. MAIN STATEMENTS 1: GI endoscopy is a resource-intensive activity with a significant yet poorly assessed environmental impact. 2: ESGE-ESGENA recommend adopting immediate actions to reduce the environmental impact of GI endoscopy. 3: ESGE-ESGENA recommend adherence to guidelines and implementation of audit strategies on the appropriateness of GI endoscopy to avoid the environmental impact of unnecessary procedures. 4: ESGE-ESGENA recommend the embedding of reduce, reuse, and recycle programs in the GI endoscopy unit. 5: ESGE-ESGENA suggest that there is an urgent need to reassess and reduce the environmental and economic impact of single-use GI endoscopic devices. 6: ESGE-ESGENA suggest against routine use of single-use GI endoscopes. However, their use could be considered in highly selected patients on a case-by-case basis. 7: ESGE-ESGENA recommend inclusion of sustainability in the training curricula of GI endoscopy and as a quality domain. 8: ESGE-ESGENA recommend conducting high quality research to quantify and minimize the environmental impact of GI endoscopy. 9: ESGE-ESGENA recommend that GI endoscopy companies assess, disclose, and audit the environmental impact of their value chain. 10: ESGE-ESGENA recommend that GI endoscopy should become a net-zero greenhouse gas emissions practice by 2050.
Collapse
Affiliation(s)
- Enrique Rodríguez de Santiago
- Gastroenterology and Hepatology Department, Hospital Universitario Ramón y Cajal, Universidad de Alcalá, Instituto Ramón y Cajal de Investigación Sanitaria (IRYCIS), and Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd), Instituto de Salud Carlos III, Madrid, Spain
| | - Mario Dinis-Ribeiro
- Porto Comprehensive Cancer Center (Porto.CCC), and RISE@CI-IPOP (Health Research Network), Porto, Portugal
| | - Heiko Pohl
- Dartmouth Geisel School of Medicine, Hanover, New Hampshire, and Section of Gastroenterology and Hepatology, VA White River Junction, Vermont, USA
| | - Deepak Agrawal
- Division of Gastroenterology and Hepatology, Dell Medical School, University of Texas Austin, Texas, USA
| | - Marianna Arvanitakis
- Department of Gastroenterology, Erasme University Hospital, Université Libre de Bruxelles, Brussels, Belgium
| | - Robin Baddeley
- King's Health Partners Institute for Therapeutic Endoscopy, King's College Hospital, and Wolfson Unit for Endoscopy, St Mark's Hospital, London, United Kingdom
| | - Elzbieta Bak
- Department of Gastroenterology and Internal Medicine, Clinical Hospital of Medical University of Warsaw, Warsaw, Poland
| | | | - Michael Bretthauer
- Clinical Effectiveness Research Group, University of Oslo, and Department of Transplantation Medicine, Oslo University Hospital, Oslo, Norway
| | - Patricia Burga
- Endoscopy Department, University Hospital of Padua, Italy
| | - Leigh Donnelly
- Endoscopy Department, Northumbria Healthcare NHS Trust, Northumberland, United Kingdom
| | - Axel Eickhoff
- Klinik für Gastroenterologie, Diabetologie, Infektiologie, Klinikum Hanau, Hanau, Germany
| | - Bu'Hussain Hayee
- Department of Gastroenterology, University College London Hospitals, London, United Kingdom
| | - Michal F Kaminski
- Department of Cancer Prevention and Department of Oncological Gastroenterology, The Maria Sklodowska-Curie National Research Institute of Oncology, Warsaw, Poland
| | - Katarina Karlović
- Clinical Hospital Center Rijeka , Department of Gastroenterology, Endoscopy Unit, Rijeka, Croatia
| | - Vicente Lorenzo-Zúñiga
- Department of Gastroenterology, University and Polytechnic La Fe Hospital/IIS La Fe, Valencia, Spain
| | - Maria Pellisé
- Department of Gastroenterology, Hospital Clinic of Barcelona, Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd), and Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Universitat de Barcelona, Barcelona, Spain
| | - Mathieu Pioche
- Endoscopy Unit, Hospices Civils de Lyon, Lyon, Auvergne-Rhône-Alpes, France
| | - Keith Siau
- Department of Gastroenterology, Dudley Group Hospitals NHS Foundation Trust, Dudley, United Kingdom
| | - Peter D Siersema
- Department of Gastroenterology and Hepatology, Radboud University Medical Center, Nijmegen, The Netherlands
| | - William Stableforth
- Department of Gastroenterology, Dudley Group Hospitals NHS Foundation Trust, Dudley, United Kingdom
| | - Tony C Tham
- Division of Gastroenterology, Ulster Hospital, Dundonald, Belfast, Northern Ireland
| | - Konstantinos Triantafyllou
- Hepatogastroenterology Unit, Second Department of Internal Medicine - Propaedeutic, Medical School, National and Kapodistrian University of Athens, Attikon University General Hospital, Athens, Greece
| | - Alberto Tringali
- Digestive Endoscopy Unit, ULSS 2 Marca Trevigiana, Conegliano Hospital, Conegliano, Italy
| | - Andrew Veitch
- Department of Gastroenterology, Royal Wolverhampton NHS Trust, Wolverhampton, United Kingdom
| | - Andrei M Voiosu
- Department of Gastroenterology and Hepatology, Colentina Clinical Hospital, Bucharest, Romania
| | - George J Webster
- Department of Gastroenterology, University College London Hospitals, London, United Kingdom
| | | | | | - Raf Bisschops
- Department of Gastroenterology and Hepatology, Catholic University of Leuven (KUL), TARGID, University Hospitals Leuven, Leuven, Belgium
| | - Cesare Hassan
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, and Endoscopy Unit, IRCCS Humanitas Clinical and Research Center, Rozzano, Milan, Italy
| | - Ian M Gralnek
- Ellen and Pinchas Mamber Institute of Gastroenterology and Hepatology, Emek Medical Center, Afula, and Rappaport Faculty of Medicine Technion Israel Institute of Technology, Haifa, Israel
| | - Helmut Messmann
- III Medizinische Klinik Universitätsklinikum Augsburg, Augsburg, Germany
| |
Collapse
|
24
|
Alfa MJ, Singh H. Contaminated flexible endoscopes: Review of impact of channel sampling methods on culture results and recommendations for root-cause analysis. Infect Control Hosp Epidemiol 2022; 43:623-638. [PMID: 33960917 DOI: 10.1017/ice.2021.128] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Recently, infection transmission risk associated with contaminated, patient-ready flexible endoscopes has attracted attention. Outbreaks of multidrug-resistant organisms resulting in infection and/or colonization have been particularly concerning. Recent CDC and FDA recommendations focus on reducing "exogenous" infection transmission and specifically recommend that endoscopy sites have quality systems in place for endoscope reprocessing. Another key recommendation is the culture of patient-ready endoscopes to detect contamination with organisms of concern. Remaining gaps in the guidelines include ensuring that optimal endoscope-channel sample methods are used and ensuring effective root-cause analysis and remediation when contamination is detected. In this review, we summarize the critical aspects of endoscope sample collection and present a practical approach to root-cause analysis and remedial action plans.
Collapse
Affiliation(s)
- Michelle J Alfa
- Department of Medical Microbiology, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Harminder Singh
- Department of Internal Medicine, University of Manitoba, Winnipeg, Manitoba, Canada
| |
Collapse
|
25
|
Ofstead CL, Hopkins KM, Eiland JE. Borescope inspection of endoscope working channels: Why and how? Endosc Int Open 2022; 10:E109-E111. [PMID: 35047340 PMCID: PMC8759935 DOI: 10.1055/a-1512-2813] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Affiliation(s)
- Cori L. Ofstead
- Ofstead and Associates, Inc., Saint Paul, Minnesota, United States
| | | | - John E. Eiland
- Ofstead and Associates, Inc., Saint Paul, Minnesota, United States
| |
Collapse
|
26
|
Garcia NB, Oliveira ACD. Storage of gastrointestinal endoscopes: when is the safe time for re-use? Rev Bras Enferm 2022; 75:e20210216. [DOI: 10.1590/0034-7167-2021-0216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Accepted: 10/13/2021] [Indexed: 11/22/2022] Open
Abstract
ABSTRACT Objectives: to identify the safe storage time for the use of flexible gastrointestinal endoscopes after high-level disinfection, as well as the defining criteria for this time. Methods: an integrative literature review was carried out in the Virtual Health Library, PubMed, Scopus, and Web of Science, considering original articles published since 2000. Results: eleven articles were selected, whose storage times ranged from 1 to 56 days, with a predominance of one to seven days (73%). Several criteria were used to define this time, predominantly the premise of efficient processing (100%), use of alcohol flush (64%), use of drying cabinets (18%), among others. Conclusions: the criteria for determining the storage time did not show a consensus for clinical practice. Expanding the discussion of this theme with the definition of the minimum necessary conditions is of fundamental importance for the reduction of risks and safety of the procedure and the patient.
Collapse
|
27
|
Thornhill G, Dunkin B. Duodenoscope-Acquired Infections: Risk Factors to Consider. JOURNAL OF DIGESTIVE ENDOSCOPY 2021. [DOI: 10.1055/s-0041-1739562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
AbstractIn the wake of highly publicized duodenoscope-associated outbreaks caused by multidrug-resistant organisms (MDRO), a herculean effort was made to understand the conditions that led to these transmission events. Although there is now a clearer picture on how these outbreaks happened, there are still significant data gaps when it comes to understanding the rate of duodenoscope-acquired infections (DAIs), especially in nonoutbreak situations. Recent publications indicate that DAIs are still occurring and suggest that infection rates are higher than currently believed. Given this data gap, it is important to identify those patient populations that are most at risk of postprocedure infection, so that appropriate infection control measures may be implemented. Although those patients receiving antibiotic prophylaxis are most at risk for infection, there are additional risk factors that should be considered. For the purposes of this review, risk factors for infection were divided into three broad categories as follows: (1) those that increase patient susceptibility to infection, (2) those related to the endoscopic procedure, and (3) those factors that put reusable duodenoscope inventories at risk of contamination. Infection risk is a complex interaction between the immune status of the patient, the characteristics of the infectious agent (antibiotic sensitivity, virulence factors, and epidemiology), and the environment of care. Because of this complexity, any assessment of the risk of infection should be performed on a case-by-case basis. There is a dearth of information on infection risk for those patients undergoing endoscopic retrograde cholangiopancreatograpy (ERCP), especially in the context of the development and implementation of new device technology, and new endoscopic procedures that are increasing in complexity. This narrative review was developed using the Medical Subject Heading (MeSH) terms to perform an electronic search in PubMed with the goal of generating a summary of the patient, procedural, and duodenoscope-associated factors that increase the risk of infection in patients undergoing ERCP. This review provides practical information regarding the segmentation of ERCP patients by infection risk, so that endoscopists can make informed decisions about the risk benefits of using enhanced duodenoscope technologies in the care of their patients.
Collapse
Affiliation(s)
- Grace Thornhill
- Infection Prevention Fellow, Boston Scientific—Endoscopy, Marlborough, Massachusetts, United States
| | - Brian Dunkin
- Chief Medical Officer, Boston Scientific—Endoscopy, Marlborough, Massachusetts, United States
| |
Collapse
|
28
|
Heuvelmans M, Wunderink HF, van der Mei HC, Monkelbaan JF. A narrative review on current duodenoscope reprocessing techniques and novel developments. Antimicrob Resist Infect Control 2021; 10:171. [PMID: 34949217 PMCID: PMC8697464 DOI: 10.1186/s13756-021-01037-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 11/19/2021] [Indexed: 11/10/2022] Open
Abstract
Duodenoscopy-associated infections occur worldwide despite strict adherence to reprocessing standards. The exact scope of the problem remains unknown because a standardized sampling protocol and uniform sampling techniques are lacking. The currently available multi-society protocol for microbial culturing by the Centers for Disease Control and Prevention, the United States Food and Drug Administration (FDA) and the American Society for Microbiology, published in 2018 is too laborious for broad clinical implementation. A more practical sampling protocol would result in increased accessibility and widespread implementation. This will aid to reduce the prevalence of duodenoscope contamination. To reduce the risk of duodenoscopy-associated pathogen transmission the FDA advised four supplemental reprocessing measures. These measures include double high-level disinfection, microbiological culturing and quarantine, ethylene oxide gas sterilization and liquid chemical sterilization. When the supplemental measures were advised in 2015 data evaluating their efficacy were sparse. Over the past five years data regarding the supplemental measures have become available that place the efficacy of the supplemental measures into context. As expected the advised supplemental measures have resulted in increased costs and reprocessing time. Unfortunately, it has also become clear that the efficacy of the supplemental measures falls short and that duodenoscope contamination remains a problem. There is a lot of research into new reprocessing methods and technical applications trying to solve the problem of duodenoscope contamination. Several promising developments such as single-use duodenoscopes, electrolyzed acidic water, and vaporized hydrogen peroxide plasma are already applied in a clinical setting.
Collapse
Affiliation(s)
- Maarten Heuvelmans
- Department of Medical Microbiology, University Medical Center Utrecht, G04.643, PO box 85500, 3508GA, Utrecht, The Netherlands.
| | - Herman F Wunderink
- Department of Medical Microbiology, University Medical Center Utrecht, G04.643, PO box 85500, 3508GA, Utrecht, The Netherlands
| | - Henny C van der Mei
- Department of Biomedical Engineering, University of Groningen and University Medical Center Groningen, Groningen, The Netherlands
| | - Jan F Monkelbaan
- Department of Gastroenterology and Hepatology, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
29
|
Peng CL, Liu TC, Wang HP, Chang WK. Two novel protocols for cleaning residual simethicone and fluid in patient-ready duodenoscopes. J Gastroenterol Hepatol 2021; 36:1843-1850. [PMID: 33274470 DOI: 10.1111/jgh.15365] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 11/01/2020] [Accepted: 11/29/2020] [Indexed: 12/09/2022]
Abstract
BACKGROUND AND AIM Approximately 42-95% of working channels have been reported to show the presence of residual fluid despite endoscope reprocessing. The aim of this study was to design two novel protocols for cleaning residual simethicone and demonstrate its efficiency by evaluating the residual fluid and cleanliness in the working channels of patient-ready duodenoscopes. METHODS The designed protocol for cleaning residual simethicone was implemented in manual cleaning and/or high-level disinfection (HLD). The residual fluid inside the working channels was estimated by visual inspection. Adenosine triphosphate (ATP) values were evaluated to determine cleanliness after manual cleaning. RESULTS Manual cleaning with novel simethicone cleaning protocol demonstrated a significant decrease in fluid droplets (14.6 ± 29.9 vs 0 ± 0, P < 0.001) and ATP values (157 ± 196 relative light units [RLUs] vs 52 ± 41 RLUs, P = 0.031). HLD with simethicone cleaning protocol, using either enzymatic detergent with effective for cleaning simethicone or cleaning time set in the automatic endoscope reprocessor program for 8 min, demonstrated significant decrease in the number of fluid droplets. Follow-up after the implementation of the simethicone cleaning protocol showed a significant decrease in fluid droplets (37.4 ± 41.0 vs 2.1 ± 5.5, P = 0.003) and ATP values (271 ± 268 RLUs vs 82 ± 136 RLUs, P = 0.021). CONCLUSIONS Simethicone cleaning protocol is advantageous for significantly decreasing fluid droplets and ATP values within endoscope working channels. After manual cleaning with the simethicone cleaning protocol, in particular, no retained fluid droplet was observed in patient-ready duodenoscopes.
Collapse
Affiliation(s)
- Chen-Ling Peng
- Department of Integrated Diagnostics and Therapeutics, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan
| | - Tao-Chieh Liu
- Division of Gastroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan
| | - Hsiu-Po Wang
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan
| | - Wei-Kuo Chang
- Division of Gastroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan
| |
Collapse
|
30
|
Abstract
Stenotrophomonas maltophilia is an opportunistic pathogen of significant concern to susceptible patient populations. This pathogen can cause nosocomial and community-acquired respiratory and bloodstream infections and various other infections in humans. Sources include water, plant rhizospheres, animals, and foods. Studies of the genetic heterogeneity of S. maltophilia strains have identified several new genogroups and suggested adaptation of this pathogen to its habitats. The mechanisms used by S. maltophilia during pathogenesis continue to be uncovered and explored. S. maltophilia virulence factors include use of motility, biofilm formation, iron acquisition mechanisms, outer membrane components, protein secretion systems, extracellular enzymes, and antimicrobial resistance mechanisms. S. maltophilia is intrinsically drug resistant to an array of different antibiotics and uses a broad arsenal to protect itself against antimicrobials. Surveillance studies have recorded increases in drug resistance for S. maltophilia, prompting new strategies to be developed against this opportunist. The interactions of this environmental bacterium with other microorganisms are being elucidated. S. maltophilia and its products have applications in biotechnology, including agriculture, biocontrol, and bioremediation.
Collapse
|
31
|
Nerandzic M, Antloga K, Litto C, Robinson N. Efficacy of flexible endoscope drying using novel endoscope test articles that allow direct visualization of the internal channel systems. Am J Infect Control 2021; 49:614-621. [PMID: 32890550 DOI: 10.1016/j.ajic.2020.08.034] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 08/25/2020] [Accepted: 08/26/2020] [Indexed: 01/30/2023]
Abstract
BACKGROUND Thorough drying of flexible endoscope channels has been identified as an essential reprocessing step. Yet, instructions are not specific on how to dry endoscopes. There is lack of data supporting efficacy of current drying practices, due to limitations in determining channel dryness. METHODS Novel endoscope test articles were used to evaluate the effectiveness of alcohol flush and hanging in an ambient endoscope storage cabinet. Prepared test articles were hung in a storage cabinet for 5 days and visually inspected for residual liquid. The procedure for preoperative inspection of endoscopic systems was performed to determine the procedure's efficacy for removing residual liquid. Then, testing was performed to assess the impact of pressure, residual liquid type and route of air application on time to dry using compressed air. RESULTS Alcohol flush followed by hanging in an ambient storage cabinet was not effective for drying endoscope channels, and residual liquid was not completely removed after performing the steps of the preoperative inspection of endoscopic channels. The factors impacting effective compressed air drying were channel dependent. For some channels, alcohol increased the time to dry. CONCLUSIONS Endoscope drying is complex; borescope evaluation does not ensure a dry device.
Collapse
Affiliation(s)
- Michelle Nerandzic
- Advanced Sterilization Group, Research and Development, STERIS Corporation, Mentor, OH.
| | - Kathleen Antloga
- Advanced Sterilization Group, Research and Development, STERIS Corporation, Mentor, OH
| | - Christine Litto
- Advanced Sterilization Group, Research and Development, STERIS Corporation, Mentor, OH
| | - Nancy Robinson
- Advanced Sterilization Group, Research and Development, STERIS Corporation, Mentor, OH
| |
Collapse
|
32
|
Foo CC, Leung WK, Lui TKL, Cheung JLK, Lam KW, Sreedhar B, Yeung CK. Feasibility study of a single-use balloon-assisted robotic colonoscope in healthy volunteers. Endosc Int Open 2021; 9:E537-E542. [PMID: 33816774 PMCID: PMC7969132 DOI: 10.1055/a-1352-3688] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 11/30/2020] [Indexed: 02/04/2023] Open
Abstract
Background and study aims Despite its widespread adoption, colonoscope still has its limitations. Advancement is often limited by the looping of colon. The isolation of SARS-CoV-2 in stool raises concern for the risk of disease transmission. A single-use robotic colonoscope, the NISInspire-C System, that features a balloon-suction anchorage mechanism was developed to address these. Methods The NISInspire-C balloons are designed to provide anchorage for straightening of the colon during advancement. Angulation at the bending section is tendon-wire driven by servo mechanisms integrated into a robotic control console. This was a pilot, prospective trial to evaluate the safety and feasibility of this system. Healthy volunteers underwent examination with the NISInspire-C, followed by the conventional colonoscope. The procedure time, cecal intubation rates (CIR), complications, and level of pain were measured. Results A total of 19 subjects underwent the examination. The cecal intubation rate was 89.5 % (17/19) and the overall time-to-cecum was 26.3 minutes (SD: 17.9 mins). There were no procedure-related complications. Polyps were detected in seven of 19 (36.8 %) subjects during the NISInspire-C procedure. Three more subjects were found to have adenomatous polyps with the conventional colonoscope. There was minimal variation in level of pain during the procedures with the two colonoscopes. Conclusion The single-use robotic colonoscope NISInspire-C is a safe and feasible alternative to the conventional colonoscope. Further technical refinement is needed to improve the CIR. This study was limited by its small sample size.
Collapse
Affiliation(s)
- Chi-Chung Foo
- Department of Surgery, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong SAR
| | - Wai-Keung Leung
- Department of Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong SAR
| | - Thomas Ka-Luen Lui
- Department of Medicine, Queen Mary Hospital, The University of Hong Kong, Hong Kong SAR
| | | | - Kwok-Wai Lam
- Bio-Medical Engineering (HK) Limited, Hong Kong SAR,Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong SAR
| | | | - Chung-Kwong Yeung
- Department of Surgery, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong SAR,Bio-Medical Engineering (HK) Limited, Hong Kong SAR
| |
Collapse
|
33
|
Voigt J, Seigerman D, Lutsky K, Beredjiklian P, Leinberry C. Comparison of the Costs of Reusable Versus Disposable Equipment for Endoscopic Carpal Tunnel Release Procedures Using Activity-Based Costing Analysis. J Hand Surg Am 2021; 46:339.e1-339.e15. [PMID: 33191039 DOI: 10.1016/j.jhsa.2020.08.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 07/03/2020] [Accepted: 08/28/2020] [Indexed: 02/02/2023]
Abstract
PURPOSE Guidelines for sterilization of reusable equipment (eg, arthroscopes, surgical equipment) have recently been established. These guidelines are supported by the U.S. Food and Drug Administration and affect costs for sterilization. The current analysis was undertaken to understand if reusable or disposable endoscopic carpal tunnel release (ECTR) equipment is a less-expensive option. METHODS An activity-based cost analysis was undertaken to determine the costs of reusable versus disposable equipment for ECTR. Costs of disposable equipment were obtained from manufacturers. Costs of processing reusable equipment including labor, time, cost of operating room time, and sterilization supplies and equipment were obtained from the literature and from recent reports identifying these costs. Infection rates and costs of infection were also factored in. Decision analysis software was used to determine the expected costs of each option (disposable vs reusable). A sensitivity analysis was undertaken on those variables that were determined to have the greatest effect on the overall costs of the procedure and sterilization. RESULTS Costs for each option when totaled were $917 for disposable and $1,019 for reusable equipment, resulting in cost savings of $102 with disposable equipment. Reusable equipment was the least costly option when the following costs/events occurred: cost of a disposable arthroscope, >$452; cost of disposable ECTR, >$647; costs of operating room time, <$28.63/min; set up time, <6.8 minutes for reusable equipment; and cost of disposable ECTR blade used with reusable equipment, <$160. CONCLUSIONS When considering the cost of operating room time, preparation, and processing of reusable equipment for ECTR, the disposable equipment for this procedure is less costly. TYPE OF STUDY/LEVEL OF EVIDENCE Economic Analysis II.
Collapse
|
34
|
Omidbakhsh N, Manohar S, Vu R, Nowruzi K. Flexible gastrointestinal endoscope processing challenges, current issues and future perspectives. J Hosp Infect 2021; 110:133-138. [PMID: 33549767 DOI: 10.1016/j.jhin.2021.01.021] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 01/14/2021] [Accepted: 01/14/2021] [Indexed: 11/18/2022]
Abstract
BACKGROUND At present, the most frequent method for processing flexible gastrointestinal (GI) endoscopes is cleaning followed by high-level disinfection as terminal sterilization is often not practicable. Post-processing monitoring studies consistently show high levels of positive cultures remaining on endoscopes, which can lead to patient infection and even fatality. The processing deficiency is attributed to the complex design of endoscopes, incomplete cleaning, formation of biofilms and lack of margin of safety with high-level disinfection. OBJECTIVE To demonstrate that flexible GI endoscopes can be practicably terminally sterilized. METHODS An endoscope sterilization cycle was developed in a vaporized hydrogen peroxide sterilization system. The cycle was used to study the sterilization of flexible GI endoscopes which included colonoscopes and duodenoscope and material compatibility for both original flexible GI endoscopes and those experimentally modified endoscopes using compatible materials. RESULTS Testing demonstrated that the vaporized hydrogen peroxide can sterilize flexible GI endoscopes (colonoscopes, duodenoscope) with a sterility assurance level of 10-6. Additionally, no recoverable survivors were detected when devices were artificially soiled with hard water and serum. Material compatibility test results demonstrated that replacing molybdenum disulphide lubricant with a graphite-based inert lubricant can make them compatible with vaporized hydrogen peroxide sterilizers. CONCLUSION Flexible GI endoscopes can be practicably terminally sterilized using vaporized hydrogen peroxide sterilization technologies if their materials are revised to become compatible.
Collapse
Affiliation(s)
- N Omidbakhsh
- Research & Development Department, Advanced Sterilization Products, Irvine, CA, USA.
| | - S Manohar
- Research & Development Department, Advanced Sterilization Products, Irvine, CA, USA
| | - R Vu
- Research & Development Department, Advanced Sterilization Products, Irvine, CA, USA
| | - K Nowruzi
- Research & Development Department, Advanced Sterilization Products, Irvine, CA, USA
| |
Collapse
|
35
|
Abstract
Since the first fiberoptic instruments, gastrointestinal endoscopy has shaped the field of gastroenterology and is now a key diagnostic and therapeutic tool. Compared with the initial fiberoptic endoscopes state-of-the-art optical chips (or charge-coupled device technology) allowed a quantum leap in image quality. Despite these advances, gastrointestinal endoscopy is far from being perfect. The diagnostic yield (eg, for adenoma detection rates) is highly operator dependent and there is still the need for sedation or even anesthesia to address discomfort during the procedure. Despite highly standardized cleaning and high-level disinfection the reuse of contemporary (and difficult to clean) endoscopes with multiple channels exposes patients to the risk of transmission of infections. Artificial intelligence and pattern recognition should eliminate interindividual variability including polyp detection rates, self-propelled, and (potentially remotely controlled) scopes with a soft shaft could reduce the discomfort during procedures and abolish the need for sedation and anesthesia altogether and single-use designs should eliminate the risk of patient-to-patient transmission of infections. While these innovations are feasible and could be implemented rapidly utilizing available technology, they require a paradigm shift affecting all levels of the value chain from the supplier of the instruments to the end-users. Some may negate the need for a paradigm shift, but it is evident that a major redesign of the endoscopic equipment is overdue to fully utilize novel technologies and most importantly ensure the best possible outcomes for patients.
Collapse
|
36
|
Day LW, Kwok K, Visrodia K, Petersen BT. American Society for Gastrointestinal Endoscopy Infection Control Summit: updates, challenges, and the future of infection control in GI endoscopy. Gastrointest Endosc 2021; 93:1-10. [PMID: 32819676 DOI: 10.1016/j.gie.2020.06.024] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Accepted: 06/09/2020] [Indexed: 02/06/2023]
Affiliation(s)
- Lukejohn W Day
- Division of Gastroenterology and Hepatology, University of California San Francisco, San Francisco, California, USA
| | - Karl Kwok
- Department of Gastroenterology, Kaiser Permanente Los Angeles Medical Center, Los Angeles, California, USA
| | - Kavel Visrodia
- Division of Gastroenterology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Bret T Petersen
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
37
|
Guidelines for infection control and prevention in anaesthesia in South Africa. SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA 2021. [DOI: 10.36303/sajaa.2021.27.4.s1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
38
|
Day LW, Muthusamy VR, Collins J, Kushnir VM, Sawhney MS, Thosani NC, Wani S. Multisociety guideline on reprocessing flexible GI endoscopes and accessories. Gastrointest Endosc 2021; 93:11-33.e6. [PMID: 33353611 DOI: 10.1016/j.gie.2020.09.048] [Citation(s) in RCA: 48] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 09/30/2020] [Indexed: 02/07/2023]
Affiliation(s)
- Lukejohn W Day
- Division of Gastroenterology and Hepatology, University of California San Francisco, San Francisco, California, USA
| | | | - James Collins
- Department of Digestive Diseases, Cleveland Clinic, Cleveland, Ohio, USA
| | - Vladimir M Kushnir
- Division of Gastroenterology, Washington University, St Louis, Missouri, USA
| | - Mandeep S Sawhney
- Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Nirav C Thosani
- Division of Gastroenterology, Hepatology and Nutrition, McGovern Medical School, UTHealth, Houston, Texas, USA
| | - Sachin Wani
- Division of Gastroenterology and Hepatology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| |
Collapse
|
39
|
Chua T, Halim N, Reicher S. Recent Advances in Endoscope Disinfection: Where Do We Stand in the COVID era? TECHNIQUES AND INNOVATIONS IN GASTROINTESTINAL ENDOSCOPY 2021; 23:190-198. [PMID: 33103131 PMCID: PMC7571422 DOI: 10.1016/j.tige.2020.10.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Over 16 million cases worldwide, severe acute respiratory syndrome coronavirus 2 has profoundly affected healthcare as we know it. Given reports of gastrointestinal involvement and viral shedding in the stool, it is unsurprising there are concerns that endoscopic equipment may be a potential vector of viral transmission. Here, we provide an overview of existing practices for endoscope reprocessing, recent developments in the field, and challenges in the COVID-19 environment. Current multi-society guidelines do not advise any change to endoscope disinfection protocols but emphasize strict adherence to recommended practices. However, endoscopy reprocessing staff may benefit from supplemental personal protective equipment measures, especially in high risk situations. Because thorough endoscope reprocessing is highly operator dependent, adequate training of personnel is critical for proper manual cleaning and disinfection of endoscopes that have potential to harbor virus. Bacterial contamination of duodenoscopes has caused outbreaks of infection from multidrug-resistant organisms, highlighting vulnerable areas. The emphasis of current studies is on optimization of disinfection and drying, minimization of simethicone use, and on quality control of endoscope reprocessing with sampling and microbiological culturing. Recent advances include novel approaches to endoscope sterilization, infection barrier methods, and design of partially or fully disposable duodenoscopes. Overall, the available data indicate that, when correctly executed, current reprocessing practices are sufficient in preventing SARS-COV-2 transmission.
Collapse
Affiliation(s)
- Tiffany Chua
- Division of Gastroenterology, Harbor-UCLA Medical Center, University of California, 21840 South Normandie Ave., Suite 850, Torrance, California 90502
| | - Nasir Halim
- Division of Gastroenterology, Harbor-UCLA Medical Center, University of California, 21840 South Normandie Ave., Suite 850, Torrance, California 90502
| | - Sofiya Reicher
- Division of Gastroenterology, Harbor-UCLA Medical Center, University of California, 21840 South Normandie Ave., Suite 850, Torrance, California 90502
| |
Collapse
|
40
|
Tian H, Sun J, Guo S, Zhu X, Feng H, Zhuang Y, Wang X. The Effectiveness of Drying on Residual Droplets, Microorganisms, and Biofilms in Gastrointestinal Endoscope Reprocessing: A Systematic Review. Gastroenterol Res Pract 2021; 2021:6615357. [PMID: 33927758 PMCID: PMC8049816 DOI: 10.1155/2021/6615357] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 03/21/2021] [Accepted: 03/23/2021] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Despite endoscope reprocessing, residual droplets remain in gastrointestinal endoscope working channels. Inadequate drying of gastrointestinal endoscope working channels may promote microbial reproduction and biofilm formation, increasing the risk of infection in patients. This review was designed to provide the current status of gastrointestinal endoscope drying, emphasize the importance of gastrointestinal endoscope drying, and evaluate the effectiveness of different drying methods of gastrointestinal endoscope in reducing residual droplets and microbial growth risk. METHODS A systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) reporting checklist. The PubMed, Web of Science, Medline, EMBASE, EBSCO, CNKI, CQVIP, and Wanfang Data databases were searched from 2010 to 2020 to identify eligible articles focused on methods of gastrointestinal endoscope drying and the status of endoscope drying. The following key points were analyzed: type of intervention, amount of residual droplets, major microbial types, and effectiveness of biofilm intervention. JBI quality assessment tool was used to determine bias risk for inclusion in the article. RESULTS This review included twelve articles. Two of the articles reported lack of drying of gastrointestinal endoscopes while the other ten reported residual droplets, microbial growth, and biofilm formation after different methods of drying. Four articles reported 0 to 4.55 residual droplets; four articles reported that the main microbial types were cocci and bacilli, most commonly Staphylococcus, Escherichia coli, Bacillus maltophilia, and Pseudomonas aeruginosa; and two reported that drying could effectively reduce biofilm regeneration. The type of intervention is as follows: automatic endoscopy reprocessor (AER), manual compressed air drying, and the Dri-Scope Aid for automatic drying and drying cabinet. CONCLUSIONS While endoscope reprocessing may not always be effective, an automatic endoscope reprocessor plus the Dri-Scope Aid with automatic drying over 10 min or storage in a drying cabinet for 72 h may be preferred.
Collapse
Affiliation(s)
- Hefeng Tian
- 1The First Hospital of Jilin University, Changchun, China
| | - Jiao Sun
- 2School of Nursing, Jilin University, No. 965 Xinjiang Street, Changchun, Jilin Province 130021, China
| | - Shaoning Guo
- 1The First Hospital of Jilin University, Changchun, China
| | - Xuanrui Zhu
- 1The First Hospital of Jilin University, Changchun, China
| | - Han Feng
- 1The First Hospital of Jilin University, Changchun, China
| | - Yijin Zhuang
- 1The First Hospital of Jilin University, Changchun, China
| | - Xiu Wang
- 1The First Hospital of Jilin University, Changchun, China
| |
Collapse
|
41
|
Ofstead CL, Buro BL, Hopkins KM, Eiland JE, Wetzler HP, Lichtenstein DR. Duodenoscope-associated infection prevention: A call for evidence-based decision making. Endosc Int Open 2020; 8:E1769-E1781. [PMID: 33269310 PMCID: PMC7671768 DOI: 10.1055/a-1264-7173] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Accepted: 07/30/2020] [Indexed: 02/07/2023] Open
Abstract
Background Recent outbreaks of duodenoscope-associated multidrug-resistant organisms (MDROs) have brought attention to the infection risk from procedures performed with duodenoscopes. Prior to these MDRO outbreaks, procedures with duodenoscopes were considered safe and low risk for exogenous infection transmission, provided they were performed in strict accordance with manufacturer instructions for use and multisociety reprocessing guidelines. The attention and efforts of the scientific community, regulatory agencies, and the device industry have deepened our understanding of factors responsible for suboptimal outcomes. These include instrument design, reprocessing practices, and surveillance strategies for detecting patient and instrument colonization. Various investigations have made it clear that current reprocessing methods fail to consistently deliver a pathogen-free instrument. The magnitude of infection transmission has been underreported due to several factors. These include the types of organisms responsible for infection, clinical signs presenting in sites distant from ERCP inoculation, and long latency from the time of acquisition to infection. Healthcare providers remain hampered by the ill-defined infectious risk innate to the current instrument design, contradictory information and guidance, and limited evidence-based interventions or reprocessing modifications that reduce risk. Therefore, the objectives of this narrative review included identifying outbreaks described in the peer-reviewed literature and comparing the findings with infections reported elsewhere. Search strategies included accessing peer-reviewed articles, governmental databases, abstracts for scientific conferences, and media reports describing outbreaks. This review summarizes current knowledge, highlights gaps in traditional sources of evidence, and explores opportunities to improve our understanding of actual risk and evidence-based approaches to mitigate risk.
Collapse
Affiliation(s)
- Cori L. Ofstead
- Ofstead & Associates, Inc., St. Paul, Minnesota, United States
| | - Brandy L. Buro
- Ofstead & Associates, Inc., St. Paul, Minnesota, United States
| | | | - John E. Eiland
- Ofstead & Associates, Inc., St. Paul, Minnesota, United States
| | | | | |
Collapse
|
42
|
Wong M, Wang Y, Wang H, Marrone AK, Haugen SP, Kulkarni K, Basile R, Phillips KS. Research: Fluorescence Microscopy-Based Protocol for Detecting Residual Bacteria on Medical Devices. Biomed Instrum Technol 2020; 54:397-409. [PMID: 33339032 DOI: 10.2345/0899-8205-54.6.397] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Standard methods are needed to reliably and efficiently assess bacterial contamination of processed medical devices. This article demonstrates a standard operating procedure (SOP) for fluorescence microscopy-based detection of residual bacteria on medical devices (BAC-VIS). BAC-VIS uses a 4',6-diamidino-2-phenylindole (DAPI) stain with fluorescent microscopy to quickly and cost-effectively detect bacterial contamination of processed medical device parts. The BAC-VIS protocol was optimized and achieved greater than 80% staining efficiency and a signal-to-noise ratio of more than 20 using four representative organisms. The SOP was first validated for use on a buildup biofilm model, accessory channels of contaminated clinically used devices, and inoculated endoscope end caps and O-rings. The buildup biofilm model was used to evaluate BAC-VIS after repeated treatment of adherent bacteria with three common high-level disinfectants: glutaraldehyde, ortho-phthalaldehyde, and peracetic acid. Next, BAC-VIS was used to assess clinically used endoscope parts that cultured positive for Gram-negative bacteria. DAPI-stained cells were found on all culture-positive devices, especially in grooves and imperfections on the surface. Finally, BAC-VIS was used to detect bacteria on inoculated endoscope device components. The results showed potential for BAC-VIS to be a valuable tool for industry and academic/medical researchers for investigations of contaminated medical devices. Results obtained using BAC-VIS can increase understanding of the role of design in cleanability, wear, and prevention of contamination and may lead to improvements in materials and design that could make processed endoscope use safer for patients. Of note, this protocol is not for detecting bacteria on scopes or scope parts that will be put back into clinical use.
Collapse
|
43
|
Barakat MT, Banerjee S. Novel Algorithms for Reprocessing, Drying and Storing Endoscopes. Gastrointest Endosc Clin N Am 2020; 30:677-691. [PMID: 32891225 DOI: 10.1016/j.giec.2020.06.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
After outbreaks of duodenoscope-transmitted infection with multidrug-resistant organisms, it has become clear that institutions must optimize their endoscope reprocessing programs. Standard endoscope reprocessing practices may not represent the ideal approach for preventing transmission of infection related to endoscopy. We discuss multiple approaches to enhance and optimize reprocessing, drying, and storage of standard duodenoscopes. The optimal enhanced duodenoscope reprocessing modality remains to be determined. Acknowledging the challenges and limitations in effectively reprocessing duodenoscopes, the FDA issued a safety communiqué recommending transitioning to either single use disposable duodenoscopes or duodenoscopes with innovative designs that allow more effective reprocessing.
Collapse
Affiliation(s)
- Monique T Barakat
- Division of Gastroenterology and Hepatology, Stanford University School of Medicine, Stanford, CA 94305, USA
| | - Subhas Banerjee
- Division of Gastroenterology and Hepatology, Stanford University School of Medicine, Stanford, CA 94305, USA.
| |
Collapse
|
44
|
Snyder GM. Introduction to Transmission of Infection: Potential Agents Transmitted by Endoscopy. Gastrointest Endosc Clin N Am 2020; 30:611-618. [PMID: 32891220 DOI: 10.1016/j.giec.2020.05.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Pathogen contamination of endoscopes depends on pathogen factors, surface factors, and environmental conditions. The most common pathogens associated with transmission and infections associated with gastrointestinal endoscope contamination are Klebsiella pneumoniae, Escherichia coli, and Pseudomonas aeruginosa. Biofilm production together with disruption to device surfaces play an outsized role in the risk of contamination. Sampling schemes are limited by these factors, and further developments are needed to improve the accuracy of sampling.
Collapse
Affiliation(s)
- Graham M Snyder
- Department of Infection Control and Hospital Epidemiology, University of Pittsburgh Medical Center, Pittsburgh, PA, USA; Division of Infectious Diseases, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA.
| |
Collapse
|
45
|
Alfa MJ. Quality Systems Approach for Endoscope Reprocessing: You Don't Know What You Don't Know! Gastrointest Endosc Clin N Am 2020; 30:693-709. [PMID: 32891226 DOI: 10.1016/j.giec.2020.06.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Several factors affect the efficacy of endoscope reprocessing, including human factors, inadequate cleaning, simethicone residuals, moisture in channels during storage, and biofilm or buildup biofilm formation. These factors all contribute to contamination of patient-ready endoscopes that may contribute to transmission of microorganisms resulting in infection and/or colonization. This article reviews monitoring as part of a quality management system that includes manual cleaning, dry storage, and culture to detect endoscope contamination. The published data for rapid tests that detect organic residuals and adenosine triphosphate to monitor manual cleaning are reviewed.
Collapse
Affiliation(s)
- Michelle J Alfa
- Department of Medical Microbiology, University of Manitoba, Winnipeg, Manitoba, Canada.
| |
Collapse
|
46
|
Luo Y, Yang Q, Li B, Yao Y. Establishment of a quality control circle to reduce biofilm formation in flexible endoscopes by improvement of qualified cleaning rate. J Int Med Res 2020; 48:300060520952983. [PMID: 32951490 PMCID: PMC7509727 DOI: 10.1177/0300060520952983] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Objective In recent years, the Emergency Care Research Institute has advised that endoscope cleaning is of considerable importance. In the present study, a quality control circle (QCC) was used to reduce the formation of biofilms in flexible endoscopes within one hospital in Guangdong Province, China. Methods During reprocessing of 235 flexible endoscopes in the urology surgical suite, adenosine triphosphate (ATP) detection was used to monitor the efficacy of biofilm removal. The internal and external parts of flexible endoscopes were used as sampling sites by means of the flushing and smudge methods, respectively. When the two results reached the standard of less than 500 relative light units/piece at the same time, endoscopic biofilm clearance was considered to be qualified. A QCC was established to implement a 10-step plan-do-check-act model. Results The baseline qualified rate (i.e., ATP monitoring pass rate) during reprocessing of 235 flexible endoscopes was 50%. During the study, the qualified rate increased to 85.29% after establishment of the QCC. During reprocessing of 150 flexible endoscopes in the following 6 months, the qualified rate remained at 90%. Conclusion Establishment of the QCC improved the removal of biofilm from flexible endoscopes in the urology surgical suite.
Collapse
Affiliation(s)
- Yingxia Luo
- Department of Urology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Qixuan Yang
- Department of Urology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Bingkun Li
- Department of Urology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Yao Yao
- Department of Medical Quality Management, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| |
Collapse
|
47
|
Endoscope infection transmission state-of-the-art: beyond duodenoscopes to a culture of infection prevention. Curr Opin Gastroenterol 2020; 36:366-369. [PMID: 32739998 DOI: 10.1097/mog.0000000000000669] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
PURPOSE OF REVIEW The elevator mechanism of the duodenoscope was the focus of endoscopically transmitted infections prior to the COVID-19 pandemic. Since that time, the 'suspicious suspects' in the endoscopy unit have grown in number in the eyes of both patients and endoscopists. RECENT FINDINGS This review summarizes the existing guidelines related to infection control in the endoscopy unit and emerging technologies to address gaps, identifies recommendations proposed during the COVID-19 pandemic, and reminds the reader that infection prevention has not changed since the emergence of COVID-19, only the importance of infection prevention has increased in visibility. SUMMARY Infection prevention has been and will always be necessary in the gastrointestinal endoscopy unit. Although outbreaks of antibiotic-resistant organisms and infectious diseases like COVID-19 raise the profile of infection control, there have been no major changes to infection control practice recommendations because of the global pandemic. The history of lapses in infection control, persistent contamination of reprocessed endoscopes, and failure of many endoscopy units to identify certain endoscopic procedures as aerosol-generating procedures prior to the pandemic emphasize the need for better knowledge and implementation of infection control practices within endoscopy units.
Collapse
|
48
|
Behm T, Robinson N. Sterilization Central: Drying and Storage of Flexible Endoscopes: An Area of Growing Concern. Biomed Instrum Technol 2020; 54:223-227. [PMID: 32442000 DOI: 10.2345/0899-8205-54.3.223] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
49
|
Liu TC, Peng CL, Wang HP, Huang HH, Chang WK. SpyGlass application for duodenoscope working channel inspection: Impact on the microbiological surveillance. World J Gastroenterol 2020; 26:3767-3779. [PMID: 32774056 PMCID: PMC7383844 DOI: 10.3748/wjg.v26.i26.3767] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 05/28/2020] [Accepted: 06/23/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Patient-ready duodenoscopes were designed with an assumed contamination rate of less than 0.4%; however, it has been reported that 5.4% of clinically used duodenoscopes remain contaminated with viable high-concern organisms despite following the manufacturer’s instructions. Visual inspection of working channels has been proposed as a quality control measure for endoscope reprocessing. There are few studies related to this issue.
AIM To investigate the types, severity rate, and locations of abnormal visual inspection findings inside patient-ready duodenoscopes and their microbiological significance.
METHODS Visual inspections of channels were performed in 19 patient-ready duodenoscopes using the SpyGlass visualization system in two endoscopy units of tertiary care teaching hospitals (Tri-Service General Hospital and National Taiwan University Hospital) in Taiwan. Inspections were recorded and reviewed to evaluate the presence of channel scratches, buckling, stains, debris, and fluids. These findings were used to analyze the relevance of microbiological surveillance.
RESULTS Seventy-two abnormal visual inspection findings in the 19 duodenoscopes were found, including scratches (n = 10, 52.6%), buckling (n = 15, 78.9%), stains (n = 14, 73.7%), debris (n = 14, 73.7%), and fluids (n = 6, 31.6%). Duodenoscopes > 12 mo old had a significantly higher number of abnormal visual inspection findings than those ≤ 12 mo old (46 findings vs 26 findings, P < 0.001). Multivariable regression analyses demonstrated that the bending section had a significantly higher risk of being scratched, buckled, and stained, and accumulating debris than the insertion tube. Debris and fluids showed a significant positive correlation with microbiological contamination (P < 0.05). There was no significant positive Spearman’s correlation coefficient between negative bacterial cultures and debris, between that and fluids, and the concomitance of debris and fluids. This result demonstrated that the presence of fluid and debris was associated with positive cultures, but not negative cultures. Further multivariate analysis demonstrated that fluids, but not debris, is an independent factor for bacterial culture positivity.
CONCLUSION In patient-ready duodenoscopes, scratches, buckling, stains, debris, and fluids inside the working channel are common, which increase the microbiological contamination susceptibility. The SpyGlass visualization system may be recommended to identify suboptimal reprocessing.
Collapse
Affiliation(s)
- Tao-Chieh Liu
- Division of Gastroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan
| | - Chen-Ling Peng
- Department of Integrated Diagnostics & Therapeutics, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei 10002, Taiwan
| | - Hsiu-Po Wang
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei 114, Taiwan
| | - Hsin-Hung Huang
- Division of Gastroenterology, Cheng Hsin General Hospital, National Defense Medical Center, Taipei 114, Taiwan
| | - Wei-Kuo Chang
- Division of Gastroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan
| |
Collapse
|
50
|
Wiktorczyk N, Kwiecińska‐Piróg J, Skowron K, Michalska A, Zalas‐Więcek P, Białucha A, Budzyńska A, Grudlewska‐Buda K, Prażyńska M, Gospodarek‐Komkowska E. Assessment of endoscope cleaning and disinfection efficacy, and the impact of endoscope storage on the microbiological safety level. J Appl Microbiol 2020; 128:1503-1513. [DOI: 10.1111/jam.14558] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 12/06/2019] [Accepted: 12/16/2019] [Indexed: 01/11/2023]
Affiliation(s)
- N. Wiktorczyk
- Department of Microbiology Nicolaus Copernicus University in Toruń Collegium Medicum of L. Rydygier Bydgoszcz Poland
| | - J. Kwiecińska‐Piróg
- Department of Microbiology Nicolaus Copernicus University in Toruń Collegium Medicum of L. Rydygier Bydgoszcz Poland
| | - K. Skowron
- Department of Microbiology Nicolaus Copernicus University in Toruń Collegium Medicum of L. Rydygier Bydgoszcz Poland
| | - A. Michalska
- Department of Microbiology Nicolaus Copernicus University in Toruń Collegium Medicum of L. Rydygier Bydgoszcz Poland
| | - P. Zalas‐Więcek
- Department of Microbiology Nicolaus Copernicus University in Toruń Collegium Medicum of L. Rydygier Bydgoszcz Poland
| | - A. Białucha
- Department of Microbiology Nicolaus Copernicus University in Toruń Collegium Medicum of L. Rydygier Bydgoszcz Poland
| | - A. Budzyńska
- Department of Microbiology Nicolaus Copernicus University in Toruń Collegium Medicum of L. Rydygier Bydgoszcz Poland
| | - K. Grudlewska‐Buda
- Department of Microbiology Nicolaus Copernicus University in Toruń Collegium Medicum of L. Rydygier Bydgoszcz Poland
| | - M. Prażyńska
- Department of Microbiology Nicolaus Copernicus University in Toruń Collegium Medicum of L. Rydygier Bydgoszcz Poland
| | - E. Gospodarek‐Komkowska
- Department of Microbiology Nicolaus Copernicus University in Toruń Collegium Medicum of L. Rydygier Bydgoszcz Poland
| |
Collapse
|