1
|
Clyburn TA, Abe EA, Jordaan K, Sheehan EC, Radoičić D, Hu Y, Courtney PM, Parvizi J. Does The Use of Ceramic Femoral Head Versus Metal Femoral Head Improve the Outcome of Primary Total Hip Arthroplasty? J Arthroplasty 2024:S0883-5403(24)01084-2. [PMID: 39447931 DOI: 10.1016/j.arth.2024.10.071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2024] [Revised: 10/10/2024] [Accepted: 10/14/2024] [Indexed: 10/26/2024] Open
Affiliation(s)
- Terry A Clyburn
- Houston Methodist Hospital, Houston Methodist Orthopedics & Sports Medicine 6445 Main St. Outpatient Center, Suite 2500, Houston, Texas 77030.
| | - Elizabeth A Abe
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Koos Jordaan
- Head Clinical Unit: Arthroplasty, Division of Orthopaedic Surgery, Department of Surgical Sciences, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, 7505, South Africa
| | - Eoin C Sheehan
- Department of Orthopaedics, Midland Regional Hospital Tullamore, Tullamore, Ireland
| | - Dragan Radoičić
- Orthopedic Surgery and Traumatology Clinic, Military Medical Academy, Crnotravska 17, 11000 Belgrade, Serbia
| | - Yihe Hu
- Department of Orthopedic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, China
| | - Paul M Courtney
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Javad Parvizi
- International Joint Center, Acıbadem Maslak Hospital, Istanbul, Türkiye
| |
Collapse
|
2
|
Wright BH, Hadley ML, Harmer JR, Fruth KM, Sierra RJ, Couch CG. No Revisions Attributable to Wear of Highly Cross-Linked Polyethylene Liners: A Long-Term Follow-Up Study. J Arthroplasty 2024; 39:S347-S352. [PMID: 38964487 DOI: 10.1016/j.arth.2024.06.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 06/14/2024] [Accepted: 06/17/2024] [Indexed: 07/06/2024] Open
Abstract
BACKGROUND There is a paucity of data beyond 15 years on the survivorship of total hip arthroplasty since the introduction of highly cross-linked polyethylene (HXLPE) liners. Our aim was to evaluate implant survivorship, liner wear rates, and clinical outcomes after primary total hip arthroplasty using HXLPE liners implanted between 1999 and 2002. METHODS Between 1999 and 2002, 690 primary total hip arthroplasties utilizing 28-mm femoral heads and HXLPE liners of a single design were identified using our institutional total joint registry. Femoral heads were made of metal in 96% of cases and ceramic in 4%. The mean age was 56 years, 48% were women, and the mean body mass index was 30. Survivorship analyses were performed for the outcomes of implant revision, reoperation, and complications for the entire cohort. Linear HXLPE liner wear rates were determined on 197 hips with radiographs with more than 18.5 years of follow-up. RESULTS At 20 years, survivorship free of revision was 94%, free of reoperation was 92%, and free of any complication was 81%. There were no documented wear-related revisions. The linear wear rate at a mean of 20.3 years postoperatively was 0.02 mm/y. There was no statistically significant difference in measured wear observed between the first available postoperative radiographs and those taken at the final follow-up. The use of elevated liners, patient body mass index, age, preoperative diagnosis, acetabular component inclination, and anteversion angles were not associated with increased wear rates. Mean Harris hip scores improved from 52 preoperatively to 90 at greater than 18.5 years CONCLUSIONS: Primary total hip arthroplasties using a single first-generation HXLPE liner demonstrated excellent survivorship and clinical outcomes at long-term follow-up with no wear-related revisions. Wear rates of HXLPE liners at 20 years are exceedingly low and are not significantly impacted by acetabular component position or patient-dependent variables such as BMI. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Breydan H Wright
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Matthew L Hadley
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Joshua R Harmer
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Kristin M Fruth
- Division of Clinical Trials and Biostatistics, Department of Quantitative Health Sciences, Mayo Clinic, Rochester, Minnesota
| | - Rafael J Sierra
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Cory G Couch
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
3
|
Hallab NJ, Hallab SR, Alexander A, Pourzal R. Characterization of residual debris on packaged hip arthroplasty stems demonstrates the dominance of less than 10 μm sized particulate: Updated USP788 guidelines for orthopedic implants. J Biomed Mater Res B Appl Biomater 2024; 112:e35387. [PMID: 38340016 DOI: 10.1002/jbm.b.35387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 10/19/2023] [Accepted: 01/27/2024] [Indexed: 02/12/2024]
Abstract
Past evaluation of particle contamination on packaged implants has typically been conducted using US Pharmacopeia (USP) 788, a 1970s pharmaceutical guideline created to evaluate contaminant particles in injectable fluids and syringes. Our objective was to reestablish relevant acceptance criteria for residual orthopedic and other implant debris, including smaller particles (i.e., <10 μm in diameter). Packaged total hip arthroplasty (THA) titanium (Ti6Al4V)-alloy femoral stems were used (hydroxyapatite [HA]-coated and non-coated stems). Short-term ultrasonication and longer-term 24-hour soak/agitation methods were used to elute surface-bound contaminant particles, and released particles were analyzed via scanning electron microscopy, energy-dispersive x-ray analysis, image analysis, and particle characterization. For HA-coated THA-stems, >99% of eluted particles were calcium phosphate. For plain non-coated THA-stems, >99% of eluted particles were titanium-alloy-based. The number-based median size of particles in both groups was approximately 1.5 μm in diameter despite being composed of different materials. The total volume of particulate removed from HA-coated stems was 0.037 mm3 (671 × 103 particles total), which was approximately >50-fold more volume than that on plain non-coated stems at 0.0006 mm3 (89 × 103 particles total). Only non-coated THA stems passed reestablished USP788 acceptance criteria, compared by using equivalent total volumes of contaminant particulate within new and legacy guideline ranges of >10 and >25 μm ECD, that is, <1.0 × 107 particles for <1 μm diameter in size, <600,000 for <1-10 μm, <6000 for 10-25 μm and <600 for >25 μm. These results fill a knowledge gap on how much residual debris can be expected to exist on packaged implants and can be used as a basis for updating acceptance criteria (i.e., termed USP788-Implant [USP788-I]). Residual implant particulate assessment is critical given the increasing implant complexity and new manufacturing techniques (e.g., additive manufacturing).
Collapse
Affiliation(s)
- Nadim J Hallab
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
- Department of Biomedical Engineering, Bioengineering Solutions Inc, Chicago, Illinois, USA
| | - Salem R Hallab
- Department of Biomedical Engineering, Bioengineering Solutions Inc, Chicago, Illinois, USA
| | - Anastasia Alexander
- Department of Biomedical Engineering, Bioengineering Solutions Inc, Chicago, Illinois, USA
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| |
Collapse
|
4
|
Migliorini F, Maffulli N, Pilone M, Bell A, Hildebrand F, Konrads C. Risk factors for liner wear and head migration in total hip arthroplasty: a systematic review. Sci Rep 2023; 13:15612. [PMID: 37730762 PMCID: PMC10511625 DOI: 10.1038/s41598-023-42809-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 09/14/2023] [Indexed: 09/22/2023] Open
Abstract
Total hip arthroplasty (THA) is a successful orthopaedic surgical procedure, and its longevity depends on bearing components and implant fixation. Optimizing polyethylene and ceramics has led to improved wear parameters and contributed to improved long-term outcomes. The present systematic review investigated whether time span from implantation, patient characteristics and performance status exert an influence on liner wear and head migration in THA. This study was conducted in conformity to the 2020 PRISMA guidelines. All the clinical investigations which reported quantitative data on the amount of liner wear and head migration in THA were considered. Only studies which reported quantitative data at least on one of the following patient characteristics were suitable: mean age, mean BMI (kg/m2), sex, side, time span between the index THA and the last follow-up (months) were eligible. A multiple linear model regression analysis was employed to verify the association between patient characteristics and the amount of liner wear and/or head migration. The Pearson Product-Moment Correlation Coefficient was used to assess the association between variables. Data from 12,629 patients were considered. The mean length of the follow-up was 90.5 ± 50.9 months. The mean age of patients at surgery was 58.4 ± 9.4 years, and the mean BMI was 27.2 ± 2.5 kg/m2. 57% (7199 of 12,629 patients) were women, and in 44% (5557 of 12,629 patients) THAs were performed on the left. The mean pre-operative Harris hip score was 46.5 ± 6.0 points. There was evidence of a moderate positive association between the amount of liner wear and the time elapsed between the index surgery to the follow-up (P = 0.02). There was evidence of a moderate positive association between the amount of head migration and the time elapsed between the index surgery to the follow-up (P = 0.01). No further statistically significant association was found. The time elapsed between the index surgery to the follow-up was the most important factor which influence the head migration and liner wear in THA. Patients' characteristics and preoperative physical activity did not influence the amount of head migration and liner wear.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano, Teaching Hospital of Paracelsus Medical University (PMU), 39100, Bolzano, Italy.
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, Simmerath, Germany.
| | - Nicola Maffulli
- Department of Orthopaedic and Trauma Surgery, Hospital Sant'Andrea, University of Rome La Sapienza, Rome, Italy
- School of Pharmacy and Bioengineering, Keele University Faculty of Medicine, Stoke on Trent, ST4 7QB, England
- Queen Mary University of London, Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Mile End Hospital, London, E1 4DG, England
| | - Marco Pilone
- Residency Program in Orthopaedics and Traumatology, University of Milan, 20122, Milan, Italy
| | - Andreas Bell
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, Simmerath, Germany
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Christian Konrads
- Department of Orthopaedics and Traumatology, Helios Hanseatic Hospital Stralsund, 18435, Stralsund, Germany
- Medical Faculty, University of Tübingen, 72076, Tübingen, Germany
| |
Collapse
|
5
|
Wilson JM, Maradit-Kremers H, Abdel MP, Berry DJ, Mabry TM, Pagnano MW, Perry KI, Sierra RJ, Taunton MJ, Trousdale RT, Lewallen DG. Comparative Survival of Contemporary Cementless Acetabular Components Following Revision Total Hip Arthroplasty. J Arthroplasty 2023; 38:S194-S200. [PMID: 37028772 PMCID: PMC10330048 DOI: 10.1016/j.arth.2023.03.093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 03/28/2023] [Accepted: 03/30/2023] [Indexed: 04/09/2023] Open
Abstract
BACKGROUND The advent of highly porous ingrowth surfaces and highly crosslinked polyethylene has been expected to improve implant survivorship in revision total hip arthroplasty. Therefore, we sought to evaluate the survival of several contemporary acetabular designs following revision total hip arthroplasty. METHODS Acetabular revisions performed from 2000 to 2019 were identified from our institutional total joint registry. We studied 3,348 revision hips, implanted with 1 of 7 cementless acetabular designs. These were paired with highly crosslinked polyethylene or dual-mobility liners. A historical series of 258 Harris-Galante-1 components, paired with conventional polyethylene, was used as reference. Survivorship analyses were performed. For the 2,976 hips with minimum 2-year follow-up, the median follow-up was 8 years (range, 2 to 35 years). RESULTS Contemporary components with adequate follow-up had survivorship free of acetabular rerevision of ≥95% at 10-year follow-up. Relative to Harris-Galante-1 components, 10-year survivorship free of all-cause acetabular cup rerevision was significantly higher in Zimmer Trabecular Metarevision (hazard ratio (HR) 0.3, 95% confidence interval (CI) 0.2-0.45), Zimmer Trabecular MetaModular (HR 0.34, 95% CI 0.13-0.89), Zimmer Trilogy (HR 0.4, 95% CI 0.24-0.69), DePuy Pinnacle Porocoat (HR 0.24, 95% CI 0.11-0.51), and Stryker Tritanium revision (HR 0.46, 95% CI 0.24-0.91) shells. Among contemporary components, there were only 23 rerevisions for acetabular aseptic loosening and no rerevisions for polyethylene wear. CONCLUSION Contemporary acetabular ingrowth and bearing surfaces were associated with no rerevisions for wear and aseptic loosening was uncommon, particularly with highly porous designs. Therefore, it appears that contemporary revision acetabular components have dramatically improved upon historical results at available follow-up.
Collapse
Affiliation(s)
- Jacob M Wilson
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Matthew P Abdel
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Daniel J Berry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Tad M Mabry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Mark W Pagnano
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Kevin I Perry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Rafael J Sierra
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | | | - David G Lewallen
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
6
|
Fransen BL, Howard LC, MacDonell T, Bengoa F, Sheridan GA, Garbuz DS, Neufeld ME. Highly crosslinked polyethylene liner thickness does not influence survival in primary total hip arthroplasty after mean follow-up of 13 years: a study of 2,565 hips with a single design liner. J Arthroplasty 2023:S0883-5403(23)00260-7. [PMID: 36931361 DOI: 10.1016/j.arth.2023.03.026] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 03/01/2023] [Accepted: 03/05/2023] [Indexed: 03/19/2023] Open
Abstract
BACKGROUND Concerns remain that thinner highly crosslinked polyethylene (HXLPE) liners in modern total hip arthroplasty (THA) may lead to premature liner-related failures or revision. The aim of this study was to evaluate the effect of liner-thickness on survival and revision rates of HXLPE in primary THA after more than 10 years. METHODS We retrospectively identified 2,565 primary THA using HXLPE with a mean follow-up of 13 years (range, 11 to 19). Patients were grouped for each millimeter (mm) of polyethylene thickness. Liner thickness varied from 4.9 to 12.7 mm, with one third measuring less than 6 mm. Primary outcomes were reoperation, all-cause revision, and liner-related revision. RESULTS The reoperation rate was 7.3%, the all-cause revision rate was 5.6%, and the liner-related revision rate was 0.04%. There was no significant difference in all-cause revision when stratified by liner thickness (P=0.286) and liner thickness was not associated with liner-related revision (n=1). There was a statistically, but not clinically significant difference in mean liner thickness for the cohort that underwent reoperation (7.09 vs 6.89 mm, P=0.01) and all-cause revision (7.16 vs 6.89 mm, P=0.031). CONCLUSION In our cohort, liner thickness was not associated with all-cause revision-free survival and there was no clinically significant difference in liner thickness between those patients who did require a reoperation or all-cause revision, and those who did not. There was only 1 liner related failure in the entire cohort. Our results indicate that using thinner HXPE liners to maximize femoral head size in THA is a safe practice that does not lead to increased revision rates or liner failure at a mean 13 years follow-up.
Collapse
Affiliation(s)
- B L Fransen
- Department of Orthopaedics, University of British Columbia, 3rd Floor, 2775 Laurel Street, Vancouver, British Columbia, V5Z 1M9, Canada.
| | - L C Howard
- Department of Orthopaedics, University of British Columbia, 3rd Floor, 2775 Laurel Street, Vancouver, British Columbia, V5Z 1M9, Canada
| | - T MacDonell
- Department of Orthopaedics, University of British Columbia, 3rd Floor, 2775 Laurel Street, Vancouver, British Columbia, V5Z 1M9, Canada
| | - F Bengoa
- Department of Orthopaedics, University of British Columbia, 3rd Floor, 2775 Laurel Street, Vancouver, British Columbia, V5Z 1M9, Canada
| | - G A Sheridan
- Department of Orthopaedics, University of British Columbia, 3rd Floor, 2775 Laurel Street, Vancouver, British Columbia, V5Z 1M9, Canada
| | - D S Garbuz
- Department of Orthopaedics, University of British Columbia, 3rd Floor, 2775 Laurel Street, Vancouver, British Columbia, V5Z 1M9, Canada
| | - M E Neufeld
- Department of Orthopaedics, University of British Columbia, 3rd Floor, 2775 Laurel Street, Vancouver, British Columbia, V5Z 1M9, Canada
| |
Collapse
|
7
|
Mertz KC, Yang J, Chung BC, Chen X, Mayfield CK, Heckmann ND. Ceramic Femoral Heads Exhibit Lower Wear Rates Compared to Cobalt Chrome: A Meta-Analysis. J Arthroplasty 2023; 38:397-405. [PMID: 36108994 DOI: 10.1016/j.arth.2022.09.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 09/06/2022] [Accepted: 09/06/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Wear between the femoral head and acetabular liners continues to limit the longevity of total hip arthroplasty implants despite advances in implant materials. The purpose of this meta-analysis was to compare linear wear rates of cobalt-chromium (CoCr) and fourth-generation ceramic femoral heads on highly cross-linked polyethylene (XLPE) liners. METHODS A systematic review following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was conducted to identify all studies between 2003 and 2020 that examined in vivo wear rates of either fourth-generation ceramics or CoCr femoral heads on XLPE liners. Studies were analyzed in a weighted means analysis of wear rates and a random effects meta-analysis. RESULTS A total of 36 studies met inclusion criteria (1,657 CoCr and 659 ceramic patients). The pooled, weighted mean wear rate was 0.063 mm/year (standard deviation [SD]: 0.061, confidence interval [CI]: 0.049-0.077) for CoCr and 0.047 mm/year (SD: 0.057, CI: 0.033-0.062; P < .01) for ceramic (P < .01). A meta-analysis of 4 studies directly comparing ceramic and CoCr found that CoCr heads demonstrated 0.029 mm/year more wear than ceramic heads (95% CI: 0.026-0.059, P = .306). Mean wear for 32-mm heads was significantly higher for ceramic (P < .01), while mean wear for 36-mm heads was significantly higher for CoCr (P < .01). CONCLUSION Fourth-generation ceramic femoral heads were found to have significantly lower wear rates than CoCr heads. Unlike previous studies, this meta-analysis included only in vivo studies and those with the same generation of highly XLPE liners.
Collapse
Affiliation(s)
- Kevin C Mertz
- Keck School of Medicine of the University of Southern California, Los Angeles, California
| | - JaeWon Yang
- University of Washington Medical Center, Seattle, Washington
| | - Brian C Chung
- Keck School of Medicine of the University of Southern California, Los Angeles, California
| | | | - Cory K Mayfield
- Keck School of Medicine of the University of Southern California, Los Angeles, California
| | - Nathanael D Heckmann
- Keck School of Medicine of the University of Southern California, Los Angeles, California
| |
Collapse
|
8
|
Fransen BL, Bengoa FJ, Neufeld ME, Sheridan GA, Garbuz DS, Howard LC. Thin highly cross-linked polyethylene liners combined with large femoral heads in primary total hip arthroplasty show excellent survival and low wear rates at a mean follow-up of 12.8 years. Bone Joint J 2023; 105-B:29-34. [PMID: 36587249 DOI: 10.1302/0301-620x.105b1.bjj-2022-0812.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
AIMS Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years' follow-up. METHODS We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear. RESULTS Overall survival rate for all-cause revision was 94.5% (95% confidence interval (CI) 81.7% to 97.2%) at a mean follow-up of 12.8 years (10.9 to 18.7). Three patients were revised, none for liner wear, fracture, or dissociation. A total of 22 patients were included in the radiological analysis (mean follow-up 9.9 years (7.5 to 13.7)). Mean linear liner wear was 0.085 mm (95% CI -0.086 to 0.257) and the volumetric wear rate was 11.097 mm3/year (95% CI -6.5 to 28.7). CONCLUSION Using HXLPE liners with 36 mm heads in 52 mm acetabular components or smaller is safe, with excellent survival and low rates of linear and volumetric wear at medium-term follow-up. Patients did not require revision surgery for liner complications such as fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads outweigh the potential risks of using thin HXLPE liners.Cite this article: Bone Joint J 2023;105-B(1):29-34.
Collapse
Affiliation(s)
- Bas L Fransen
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Francisco J Bengoa
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Michael E Neufeld
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Gerard A Sheridan
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Donald S Garbuz
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Lisa C Howard
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| |
Collapse
|
9
|
Sax OC, Douglas SJ, Chen Z, Mont MA, Nace J, Delanois RE. Low Wear at 10-Year Follow-Up of a Second-Generation Highly Cross-Linked Polyethylene in Total Hip Arthroplasty. J Arthroplasty 2022; 37:S592-S597. [PMID: 35210151 DOI: 10.1016/j.arth.2022.01.016] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 12/27/2021] [Accepted: 01/06/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Characterizations and factors influencing longer term performance of second-generation sequentially irradiated and annealed highly cross-linked polyethylene (HXLPE) are lacking. We evaluated patients who underwent total hip arthroplasty with HXLPE at mean 10-year follow-up for (1) linear and volumetric wear rates, (2) patient and implant characteristics, (3) implant survivorships, and (4) functional scores. METHODS We evaluated 130 hips (110 patients) that received HXLPE acetabular liners at a single center. The mean age was 56 years (range, 20-79 years), with a mean follow-up of 10 years (range, 8-15). Radiographic linear (millimeters/year) and volumetric (cubic millimeters/year) wear rates were quantified using radiographic analysis. Survivorship was assessed by all-cause and wear-related revision rates. Functional outcomes were assessed by Short Form 12 and modified Harris Hip Scores. RESULTS The mean linear wear rate was 0.02 ± 0.03 mm/y, and the mean volumetric wear rate was 12.6 ± 5.3 mm3/y. Younger age had higher volumetric wear (total and yearly, P = .01). Increasing body mass index trended toward higher total and yearly linear (both, P ≤ .09) and volumetric wear (both, P ≤ .07). Ten patients required revisions, with an all-cause survivorship of 92% and a wear survivorship of 100%. The mean modified Harris Hip Scores was 84, and the mean Short Form 12 scores were 46 (physical) and 55 (mental). CONCLUSION We observed low linear and volumetric wear rates for HXLPE at 10-year mean follow-up. Younger age and higher body mass index at the time of surgery may be important patient characteristics influencing long-term wear. These results illustrate the potential for this second-generation HXLPE to be an appropriate long-term total hip arthroplasty interface.
Collapse
Affiliation(s)
- Oliver C Sax
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| | - Scott J Douglas
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| | - Zhongming Chen
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| | - Michael A Mont
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| | - James Nace
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| | - Ronald E Delanois
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| |
Collapse
|
10
|
Pairing 40-mm Femoral Heads With the Smallest Compatible Acetabular Components in Total Hip Arthroplasty: Mid-Term Outcomes in 177 Cases. J Arthroplasty 2022; 37:S582-S587. [PMID: 35256235 DOI: 10.1016/j.arth.2022.01.090] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/24/2022] [Accepted: 01/29/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Contemporary total hip arthroplasty (THA) often employs larger femoral heads to optimize hip stability. However, pairing 40-mm femoral heads with the smallest compatible acetabular components poses a potential risk for implant failure. The purpose of this study is to evaluate the outcomes of primary THAs using 40-mm femoral heads and the smallest compatible acetabular components. METHODS Between 2007 and 2018, 177 primary THAs involving 40-mm femoral heads and acetabular components ≤56 mm with highly cross-linked polyethylene liners were identified. Mean age was 61 years, 56% were females, and mean body mass index was 32 kg/m2. Cumulative incidences of dislocation, any revision, and any reoperation were determined utilizing a competing risk model. Osteolysis and femoral head penetration were assessed at minimum 8-year follow-up (n = 16). Mean follow-up was 6 years. RESULTS There were no cases of liner fractures or dissociations. The 10-year cumulative incidences of dislocation, any revision, and any reoperation were 3.6%, 4.2%, and 6.8%, respectively. Mean linear femoral head penetration was 0.01 mm/y and mean volumetric wear rate was 50 mm3/y. One THA demonstrated stable, asymptomatic periacetabular radiolucent lines at most recent follow-up. CONCLUSION In 177 primary THAs pairing 40-mm femoral heads with the smallest compatible acetabular components, there were no liner fractures or dissociations. The cumulative incidence of dislocation was modest at 10 years. The cumulative incidences of any revision and any reoperation were low at mid-term. LEVEL OF EVIDENCE IV.
Collapse
|
11
|
Debbi EM, Quevedo González FJ, Jerabek SA, Wright TM, Vigdorchik JM. Three-Dimensional Functional Impingement in Total Hip Arthroplasty: A Biomechanical Analysis. J Arthroplasty 2022; 37:S678-S684. [PMID: 35271980 DOI: 10.1016/j.arth.2022.02.112] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 02/24/2022] [Accepted: 02/25/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Although component offset can affect impingement after total hip arthroplasty, the exact impact is unclear. Evaluation of offset on an anterior-posterior pelvic radiograph is different than evaluation in functional positions of impingement, namely flexion/internal rotation and extension/external rotation. We quantified the effect of acetabular (cup/liner) vs femoral (head/stem) offsets on changes in range of motion to extra-prosthetic impingement in these 2 impingement-prone functional positions. METHODS We retrospectively identified 16 total hip arthroplasty patients (age 61.5 ± 12.1 years, body mass index 28.3 ± 4.9 kg/m2) with preoperative and postoperative computerized tomography scans. To eliminate metal artifact, femoral and pelvic 3-dimensional models were created using preoperative scans aligned with postoperative scans, and 3-dimensional scanned implant models were used to reproduce clinical implantation. We tested ±5 mm acetabular cup, acetabular liner, femoral stem, and femoral head offsets. Maximum range of motion (ROM) to bone-bone impingement was calculated for internal rotation at 90° flexion and external rotation at 10° extension. RESULTS In all cases, increased offset increased ROM to impingement, and vice versa. During internal rotation at 90° flexion, ±5 mm liner offset had the greatest impact on ROM (+9°/-10°), followed by cup (+8°/-9°), head (+5°/-7°), and stem (+3°/-5°) offset. During external rotation at 10° extension, ±5 mm cup offset had the greatest impact on ROM (+10°/-10°), followed by liner (+9°/-9°), head (+7°/-8°), and stem (+4°/-4°) offset. However, no statistically significant differences were found in the changes to ROM in flexion obtained through cup and liner offsets, the changes to ROM in extension obtained through liner and head offsets, and the changes to ROM in extension obtained through increasing stem and head offsets. CONCLUSION Increasing offset by any method reduces impingement. Center-of-rotation offset changes via acetabular cup or liner have the greatest impact on extra-prosthetic impingement.
Collapse
Affiliation(s)
- Eytan M Debbi
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| | | | - Seth A Jerabek
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, NY
| | - Jonathan M Vigdorchik
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY
| |
Collapse
|
12
|
Babazadeh S, de Steiger RN, Peng Y, van Bavel D. Stainless Steel Femoral Heads Reduce Rate of Revision When Compared to Ion-Implanted Chromium-Cobalt Heads With a Single Cemented Femoral Design: An Analysis of 40,468 Total Hip Replacements From the Australian Orthopedic Association National Joint Replacement Registry. J Arthroplasty 2021; 36:3945-3949. [PMID: 34521567 DOI: 10.1016/j.arth.2021.08.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 08/03/2021] [Accepted: 08/23/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND In order to reduce the incidence of total hip joint replacement revision for wear, multiple advanced materials and alloys targeting hip replacement tribology have been introduced. Ion implantation of chromium-cobalt heads is thought to reduce wear due to increased surface hardness and lower friction. These advances in technology result in additional manufacturing costs. However, it is unclear whether these attributes result in a decreased rate of revision for wear and when used with modern highly crosslinked polyethylene (XLPE). The aim of this study is to compare the survivorship of stainless steel and ion-implanted chromium-cobalt femoral heads in order to determine whether ion implantation has a lower risk of revision. METHODS Data from the Australian Orthopedic Association National Joint Replacement Registry included all stainless steel and low-friction ion-treated (LFIT) femoral heads used in conjunction with a primary Exeter/Trident hip replacement combination and XLPE liners performed for osteoarthritis. Kaplan-Meier estimates of survivorship were used to describe the time to first revision. Hazard ratios (HRs) from Cox proportional hazard models, with adjustment for age and gender, were used to compare revision rates between the 2 groups. RESULTS There were 40,468 total hip replacements that met the inclusion criteria. Stainless steel heads had a lower revision rate compared to LFIT chromium-cobalt heads (HR 0.87, 95% confidence interval 0.76-1.00, P = .048). The difference in the rate of revision was even greater when 32-mm heads were used (HR 0.72, 95% confidence interval 0.58-0.89, P = .002). There was no difference in revision for loosening between head alloys or when stratified by age. CONCLUSION Given the increased costs associated with LFIT implants and the lower rate of revision for stainless steel heads, we recommend the use of a stainless steel heads when using an Exeter/Trident hybrid hip with an XLPE liner.
Collapse
Affiliation(s)
- Sina Babazadeh
- Department of Orthopaedics, St. Vincent's Hospital (Melbourne), Fitzroy, Victoria, Australia; Department of Surgery, University of Melbourne, Richmond, Victoria, Australia; Australian Orthopaedic Research Group, Kew East, Victoria, Australia
| | - Richard N de Steiger
- Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), Adelaide, South Australia, Australia; Department of Surgery, Epworth Healthcare, University of Melbourne, Richmond, Victoria, Australia
| | - Yi Peng
- South Australian Health and Medical Research Institute (SAHMRI), Adelaide, South Australia, Australia
| | - Dirk van Bavel
- Department of Orthopaedics, St. Vincent's Hospital (Melbourne), Fitzroy, Victoria, Australia; Department of Surgery, Epworth Healthcare, University of Melbourne, Richmond, Victoria, Australia
| |
Collapse
|
13
|
Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 Years. Arthroplast Today 2021; 11:140-145. [PMID: 34541267 PMCID: PMC8435938 DOI: 10.1016/j.artd.2021.08.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 06/25/2021] [Accepted: 08/03/2021] [Indexed: 11/24/2022] Open
Abstract
Background There is a paucity of data on the long-term performance of highly cross-linked polyethylene (HXLPE). Therefore, this study evaluated 10-year 1) functional, 2) radiographic, and 3) surgical outcomes in patients who underwent total hip arthroplasty with sequentially irradiated and annealed HXLPE. Methods A retrospective, multicenter study was conducted on patients who underwent primary total hip arthroplasty and received HXLPE polymer (n = 151). Two-dimensional radiographic linear and volumetric wear analyses were quantified using the Martell Hip Analysis software, while functional outcomes were assessed by analyzing postoperative Short-Form-12 (SF-12) Physical and Mental Health Surveys and Harris Hip Scores. Radiographic outcomes included yearly linear (mm/y) and volumetric (mm3/y) wear rates. Surgical outcomes included additional operations and survivorship. Results SF-12 scores were within 1 standard deviation (SD) of the normal population (SF-12 Physical: 47.0; SF-12 Mental: 52.0), while the Harris Hip Scores of 89.5 was borderline between “good” and “excellent.” Total and annual linear wear rates were 0.164 mm (SD: 0.199 mm) and 0.015 mm/y (SD: 0.018 mm/y), respectively. The mean total volumetric wear rate was 141.4 mm3 (SD: 165.0) and 12.6 mm3/y (SD: 14.9 mm3/y) when broken down into a yearly rate. Eleven patients required revisions, resulting in an all-cause polyethylene survivorship of 92.7%, with a polyethylene wear survivorship of 100.0%. Conclusions Our results demonstrate clinically undetectable linear and volumetric wear rates after 10 years in those who received the unique sequentially irradiated and annealed HXLPE. Furthermore, high rates of survivorship coupled with low all-cause revision rates illustrate the polymers' capability to potentially increase implant longevity.
Collapse
|
14
|
Baker CE, Bukowski BR, Abdel MP, Trousdale RT. The Lawrence D. Dorr Surgical Techniques & Technologies Award: Using Big Heads and Small Acetabular Components With Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: Is It Safe? J Arthroplasty 2021; 36:S11-S17. [PMID: 33622530 DOI: 10.1016/j.arth.2021.01.067] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 01/06/2021] [Accepted: 01/24/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Contemporary total hip arthroplasty (THA) employs larger femoral heads to optimize hip stability. However, the combination of large femoral heads and comparatively small acetabular components poses a potential risk for implant failure secondary to polyethylene (PE) liner fracture or dissociation. The purpose of this study was to evaluate the incidence of liner fracture or dissociation, implant survivorship, and PE wear rates in primary THAs using large femoral heads and small acetabular components. METHODS Between 2000 and 2017, we retrospectively identified 882 primary THAs with 36 mm femoral heads and acetabular components ≤52 mm with highly cross-linked polyethylene liners. Mean age was 66 years, 88% were females, and mean body mass index was 30 kg/m2. We evaluated the cumulative incidences of dislocation, any revision, and any reoperation utilizing a competing risk model. Osteolysis and femoral head penetration were assessed with a validated radiographic technique at minimum 10-year follow-up (n = 18). Mean follow-up was 4 years. RESULTS There were no liner fractures or dissociations in the entire cohort. The 10-year cumulative incidences of dislocation, any revision, and any reoperation were 3.2%, 5.6%, and 9.3%, respectively. Mean linear femoral head penetration was 0.042 mm/y and mean volumetric wear rate was 44 mm3/y. No THAs demonstrated evidence of osteolysis or component loosening at long-term follow-up. CONCLUSION In a large cohort of primary THAs pairing large femoral heads with small acetabular components, there was no evidence of liner fracture or dissociation. Cumulative incidences of dislocation, any revision, and any reoperation were low at mid-term. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
| | | | - Matthew P Abdel
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN
| | | |
Collapse
|
15
|
Hemmilä M, Laaksonen I, Matilainen M, Eskelinen A, Haapakoski J, Puhto AP, Kettunen J, Pamilo K, Mäkelä KT. Implant survival of 2,723 vitamin E-infused highly crosslinked polyethylene liners in total hip arthroplasty: data from the Finnish Arthroplasty Register. Acta Orthop 2021; 92:316-322. [PMID: 33517823 PMCID: PMC8231410 DOI: 10.1080/17453674.2021.1879513] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The use of crosslinked polyethylene in total hip arthroplasty (THA) has decreased wear remarkably. It has been suggested that the antioxidative effects of vitamin E may enhance the wear properties of polyethylene even further. This study evaluates revision rates between vitamin E-infused polyethylene liners (E1 and E-poly, ZimmerBiomet, Warsaw, IN, USA) versus moderately crosslinked polyethylene (ModXLPE) liners from the same manufacturer used in primary THA.Patients and methods - We conducted a study based on data from the Finnish Arthroplasty Register. The study group consisted of 2,723 THAs with a vitamin E-infused liner and a reference group of 2,707 THAs with a moderately crosslinked polyethylene liner. Survivorship, revision risk, and re-revision causes were compared between groups.Results - The 7-year survival of the vitamin E-infused polyethylene liner group and of the reference group with revision for any reason as the endpoint was comparable (94% [95% CI 92.9-94.9] and 93% [CI 91.9-93.9], respectively). The adjusted hazard ratio (HR) for any revision was similar between the groups (0.7 [CI 0.4-1.1]). When revision for aseptic loosening was studied as the endpoint, the survival for the study group was 99% (CI 98.6-99.4) and for the reference group 99% (CI 98.7-99.5), and the risk of revision was comparable between the study groups (HR 1.3 [CI 0.7-2.5]).Interpretation - After an observation period of 7 years vitamin E-infused liners shows results equal to results obtained with crosslinked polyethylene liners.
Collapse
Affiliation(s)
- Matias Hemmilä
- Department of Orthopaedic Surgery, University of Turku and Turku University Hospital, Turku; ,Correspondence:
| | - Inari Laaksonen
- Department of Orthopaedic Surgery, University of Turku and Turku University Hospital, Turku;
| | - Markus Matilainen
- Turku PET Centre, University of Turku and Turku University Hospital, Turku;
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement and Faculty of Medicine and Health Technologies, Tampere University, Tampere;
| | | | - Ari-Pekka Puhto
- Division of Operative Care, Department of Orthopaedic and Trauma Surgery, Oulu University Hospital, Oulu;
| | - Jukka Kettunen
- Department of Orthopaedics and Traumatology, Kuopio University Hospital, Kuopio, Finland
| | - Konsta Pamilo
- Coxa Hospital for Joint Replacement and Faculty of Medicine and Health Technologies, Tampere University, Tampere;
| | - Keijo T Mäkelä
- Department of Orthopaedic Surgery, University of Turku and Turku University Hospital, Turku;
| |
Collapse
|
16
|
Sang S, Guo G, Yu J, Zhang X. Antibacterial application of gentamicin-silk protein coating with smart release function on titanium, polyethylene, and Al 2O 3 materials. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 124:112069. [PMID: 33947562 DOI: 10.1016/j.msec.2021.112069] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 03/02/2021] [Accepted: 03/16/2021] [Indexed: 01/12/2023]
Abstract
Peri-implant infection after hip and knee arthroplasty is a common and serious complication. Titanium (Ti), polyethylene (PE), and Al2O3 materials used as joint prosthesis materials have good biocompatibility and mechanical strength but no antibacterial effect. This study aimed to provide a theoretical basis for the design and manufacture of joint prosthesis materials with antibacterial effect. We applied a coating of gentamicin-silk protein (GS-Silk) on the surface of these materials. We characterized the Ti, PE, and Al2O3 materials coated with GS-Silk (experimental group) and performed in vivo and in vitro experiments to test antibacterial activity. Scanning electron microscopy confirmed successful GS-Silk coating, and infrared spectroscopy confirmed successful loading of gentamicin onto the three materials. Nanoscratch test proved that the GS-Silk coating is relatively reliable on the surface of these three materials. The antibacterial effect of the coating in vitro and in vivo was verified by performing bacteriostatic ring test in vitro, bacterial adhesion test, and subendothelial implant infection test. We demonstrated that GS-Silk coating can effectively load gentamicin onto Ti, PE, and Al2O3 materials and change the gentamicin release rate with a change in the solution pH to achieve intelligent release. The GS-Silk coating is relatively reliable on the surface of these three materials. Ti, PE, and Al2O3 materials coated with GS-Silk have good antibacterial ability, both in vivo and in vitro.
Collapse
Affiliation(s)
- Shang Sang
- Department of Orthopaedics, Shanghai Jiao Tong University, Affiliated Sixth People's Hospital, Shanghai, China
| | - Geyong Guo
- Department of Orthopaedics, Shanghai Jiao Tong University, Affiliated Sixth People's Hospital, Shanghai, China
| | - Jinlong Yu
- Department of Orthopaedics, Shanghai Jiao Tong University, Affiliated Sixth People's Hospital, Shanghai, China
| | - Xianlong Zhang
- Department of Orthopaedics, Shanghai Jiao Tong University, Affiliated Sixth People's Hospital, Shanghai, China.
| |
Collapse
|
17
|
Munakata Y, Kuramitsu Y, Usui Y, Okazaki K. Comparison of radiographic changes in rectangular curved short stem with thin versus thick porous coating for cementless total hip arthroplasty: a retrospective study with a propensity score matching. J Orthop Surg Res 2021; 16:247. [PMID: 33849591 PMCID: PMC8042942 DOI: 10.1186/s13018-021-02397-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Accepted: 04/05/2021] [Indexed: 11/12/2022] Open
Abstract
Background Radiographic changes that appear relatively quickly after fixation of cementless stem in total hip arthroplasty (THA) vary depending on the stem design and fixation style. The present study compared radiographic changes between two types of rectangular curved short stems of similar shape. Methods This retrospective study included 118 hips that underwent primary cementless THA with an anterolateral supine approach using a rectangular, curved, short stem performed by the same surgeon between June 2015 and June 2019. Among the examined hips, 39 had a thicker porous coating stem (thicker group) and 66 had a thinner porous coating and reduced tip stem (thinner group) and at least 12-month follow-up. Radiographs taken during the final course observation were assessed. Propensity score matching was performed based on demographic data and comparisons were made using pairs of 25 hips each. Statistical analysis was performed using chi-square test and p values ≤ 0.05 indicated statistical significance. Results The pattern of the radiolucent lines showed a significant difference after matching (p = 0.0044). A “proximal and distal” pattern was most common in the thicker group and a “distal only” pattern was most common in the thinner group. There was notable and significant difference in cortical hypertrophy in the thicker group after matching (p = 0.024). Conclusions Although the two short stems were similar shapes, the short-term radiographic changes were different. The thinner group showed fewer radiographic changes than the thicker group, making it a more “silent” stem.
Collapse
Affiliation(s)
- Yutaro Munakata
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Yujiro Kuramitsu
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Yutaka Usui
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Ken Okazaki
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan.
| |
Collapse
|
18
|
Bergvinsson H, Sundberg M, Flivik G. Polyethylene Wear With Ceramic and Metal Femoral Heads at 5 Years: A Randomized Controlled Trial With Radiostereometric Analysis. J Arthroplasty 2020; 35:3769-3776. [PMID: 32763006 DOI: 10.1016/j.arth.2020.06.057] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 06/15/2020] [Accepted: 06/18/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND A common bearing combination in total hip arthroplasty today is a metal femoral head articulating with polyethylene in the cup. Ceramic heads are thought to be more resistant to third-body damage, and have better wettability and decreased surface roughness, which taken together have been suggested to result in less polyethylene wear. The purpose of this study is to compare the initial creep deformation and follow wear pattern, using radiostereometric analysis, of ceramic and metal femoral heads that articulate with a modern highly cross-linked polyethylene cup liner. METHODS Fifty patients with primary osteoarthritis and scheduled for an uncemented total hip arthroplasty were randomized 1:1 to either a ceramic (BIOLOX delta) or a metal (CoCr) femoral head. The patients were followed up for 5 years with repeated radiostereometric analysis examinations (postoperatively, then at 14 days, 3, 12, 24, and 60 months), as well as a hip-specific outcome questionnaire. RESULTS During the first 3 months both groups showed expected creep within the liner of 0.12 mm (standard deviation 0.03) for the ceramic and 0.08 mm (standard deviation 0.02) for the metal heads. Between 3 months and 5 years there was very little wear of the liner in either group, corresponding to 0.003 mm/y for ceramic and 0.007 mm/y for metal heads. There was no difference in cup migration or clinical outcome between the groups and no cups were revised. CONCLUSION With the introduction of modern highly cross-linked polyethylene, the ceramic head demonstrates no superiority when it comes to either early deformation or polyethylene wear compared with the metal head.
Collapse
Affiliation(s)
- Halldor Bergvinsson
- Department of Orthopedics, Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden
| | - Martin Sundberg
- Department of Orthopedics, Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden
| | - Gunnar Flivik
- Department of Orthopedics, Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden
| |
Collapse
|
19
|
Falotico GG, Takata P, Jacob LS, Roesler CRDM, Romero V, Takata ET. Estudo biomecânico comparativo do desgaste do polietileno reticulado com cabeças femorais cerâmicas de 36 mm e com cabeças metálicas de 32 mm. Rev Bras Ortop 2020; 55:597-604. [PMID: 33132462 PMCID: PMC7593114 DOI: 10.1055/s-0040-1708518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2019] [Accepted: 11/12/2019] [Indexed: 10/25/2022] Open
Abstract
Resumo
Objetivo: O objetivo do presente estudo foi comparar, in vitro, a taxa de desgaste do polietileno de alto peso molecular reticulado acoplado a cabeças cerâmicas de 36 mm de diâmetro e acoplado a cabeças metálicas de 32 mm de diâmetro.
Métodos: Foram realizados ensaios biomecânicos em simulador de desgaste para os pares tribológicos cerâmica-poli (36 mm) e metal-poli (32 mm) a fim de verificar a taxa de desgaste após em 15 × 106 ciclos.
Resultados: Na comparação entre as medidas de taxa de desgaste dos conjuntos com cabeças metálicas (média:14,12 mg/MC) e cerâmicas (média:7,46 mg/MC) houve diferença estatitsticamente significativa (p = 0,0005).
Conclusão: O presente estudo demonstrou menor taxa de desgaste em conjuntos protéticos que utilizaram o par tribológico cerâmica-polietileno reticulado de 36 mm em comparação aos conjuntos com metal-polietileno reticulado de 32 mm. Tal achado demonstra a eficácia do par tribológico cerâmica-poli, mesmo com a utilização de cabeças de grande diâmetro.
Collapse
Affiliation(s)
- Guilherme Guadagnini Falotico
- Disciplina de Ortopedia e Traumatologia, Grupo de Quadril Adulto, Universidade Federal de São Paulo (Unifesp), São Paulo, SP, Brasil
| | - Pedro Takata
- Disciplina de Ortopedia e Traumatologia, Grupo de Quadril Adulto, Universidade Federal de São Paulo (Unifesp), São Paulo, SP, Brasil
| | - Leonardo Salani Jacob
- Disciplina de Ortopedia e Traumatologia, Grupo de Quadril Adulto, Universidade Federal de São Paulo (Unifesp), São Paulo, SP, Brasil
| | | | - Valéria Romero
- Universidade Estadual de Campinas (Unicamp), Campinas, SP, Brasil
| | - Edmilson Takehiro Takata
- Disciplina de Ortopedia e Traumatologia, Grupo de Quadril Adulto, Universidade Federal de São Paulo (Unifesp), São Paulo, SP, Brasil
| |
Collapse
|
20
|
Jalali O, Scudday T, Fickenscher MC, Barnett S, Gorab R. Third-Generation Medium Cross-Linked Polyethylene Demonstrates Very Low Wear in Total Hip Arthroplasty. Arthroplast Today 2020; 6:316-321. [PMID: 32514421 PMCID: PMC7267711 DOI: 10.1016/j.artd.2020.04.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Revised: 02/21/2020] [Accepted: 04/07/2020] [Indexed: 02/08/2023] Open
Abstract
Background Cross-linked polyethylene (XLPE) liners have shown lower wear rates than conventional polyethylene liners in total hip arthroplasty. The primary aim of our study was to report our most recent analysis of wear rates and clinical outcomes of a third-generation XLPE liner. Secondary aims were to investigate the rate of adverse events related to mechanical failure or oxidation of this liner. Methods A series of 266 total hip arthroplasties using a specific XLPE liner were retrospectively reviewed. Radiographs were examined to determine linear and volumetric wear rates and presence of osteolysis. Clinical outcomes, revision rates, mechanical failures, and risk factors for accelerated polyethylene wear were additionally investigated. Results The mean age at the time of surgery was 65.8 years and the mean follow-up was 5.5 years. The mean linear wear rate was 0.003 mm/year and the mean volumetric wear rate was 0.42 mm3/year, and there was no evidence of osteolysis. Harris hip scores increased from 50.9 preoperatively to 96.0 at the latest follow-up. The revision rate was 0.4%, with no liner rim fractures and no liner dissociations/loosenings. Femoral head material, head size, age, body mass index, and time since implantation had no effect on wear rates. Conclusion Wear rates for this third-generation XLPE liner were low at mid-term follow-up, and no adverse sequelae of oxidation or deleterious mechanical properties were observed. This remained true regardless of femoral head size and material or patient age and body mass index. Further analysis will be necessary to ensure continued wear resistance, oxidative stability, and mechanical strength at long-term follow-up.
Collapse
Affiliation(s)
- Omid Jalali
- Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | | | | | | | | |
Collapse
|
21
|
Langlois J, Hamadouche M. Recent update on crosslinked polyethylene in total hip arthroplasty. SICOT J 2020; 6:13. [PMID: 32412408 PMCID: PMC7227368 DOI: 10.1051/sicotj/2020013] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 04/23/2020] [Indexed: 02/02/2023] Open
Abstract
More than two decades after their clinical introduction, crosslinked polyethylenes (XLPE) have been widely adopted. Though concerns were initially raised regarding oxidation and brittleness, on a large scale, the first generation of XLPE continues to be highly effective 15 years after the surgery, even in a young and active population. Remelted XLPE might display lower wear rates than annealed XLPE. Second generation XLPEs, not only including sequentially irradiated and annealed but also associated with antioxidants, demonstrate encouraging short- to mid-term results. Registry data support clinical trial reports. Even in less favorable settings (lipped liners, dual mobility cups, revision surgery, hip resurfacing) results are promising. However, failures (fractures) have already been described. Therefore, a high level of surveillance remains crucial.
Collapse
Affiliation(s)
- Jean Langlois
-
Centre Orthopédique Santy 24, avenue Paul Santy 69008 Lyon France
-
Hôpital Privé Jean-Mermoz 55, avenue Jean-Mermoz 69008 Lyon France
| | - Moussa Hamadouche
-
Département de Chirurgie Orthopédique, Université Paris-Descartes, Assistance Publique-Hôpitaux de Paris, Hôpital Cochin 27, rue du Faubourg Saint-Jacques 75014 Paris France
| |
Collapse
|
22
|
Carli AV, Patel AR, Cross MB, Mayman DJ, Carroll KM, Pellicci PM, Jerabek SA. Long-term performance of oxidized zirconium on conventional and highly cross-linked polyethylene in total hip arthroplasty. SICOT J 2020; 6:10. [PMID: 32378510 PMCID: PMC7204272 DOI: 10.1051/sicotj/2020010] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 04/16/2020] [Indexed: 11/14/2022] Open
Abstract
Introduction: Polyethylene wear and subsequent osteolysis remain obstacles to the long-term survivorship of total hip arthroplasty (THA). Highly cross-linked polyethylene (XLPE) with radical quenching represents a massive leap forward with dramatically improved wear rates compared to ultra-high molecular weight polyethylene (UHMWPE). In this study we evaluate the wear of UHMWPE and XLPE coupled with oxidized zirconium (OxZr) femoral heads. Methods: A longitudinal, retrospective analysis was performed identifying consecutive patients who received a 28-mm OxZr-on-polyethylene primary THA from 2003 to 2004 by a single, high-volume arthroplasty surgeon. Patients were divided into two groups: those that received (1) UHMWPE liner and (2) a highly XLPE liner. Patients were included if clinical follow-up was complete to 2014 or later. Radiographic analysis was performed by two blinded observers. Measures included cup position, annual linear wear rate, and presence of osteolysis. Pairwise comparisons, correlations, and inter-rater reliability were calculated. Results: Eighty patients were in the UHMWPE group with an average follow-up of 10 ± 1.23 years and 88 patients in the XLPE group with an average of 10 ± 1.03-year follow-up. Average age (68) was similar between groups (p = 0.288). Observer reliability was excellent for cup abduction (ICC = 0.940), anteversion (ICC = 0.942), and detection of osteolysis (ICC = 0.811). Annual linear wear rates were significantly higher (p = 1 × 10−19) with UHMWPE (0.21 ± 0.12 mm/year) compared to XLPE (0.05 ± 0.03 mm/year). Linear wear rate was significantly correlated to decreasing acetabular abduction (p = 0.035). Osteolysis was noted only in the UHMWPE group, with 17 patients (21.2%) exhibiting acetabular osteolysis and 37 (46.3%) patients exhibiting femoral osteolysis. Conclusions: OxZr coupled with XLPE showed minimal wear and no osteolysis at 10-year follow up. The yearly linear penetration rate is similar to that seen in other studies of XLPE THA. A careful longitudinal follow-up will be required to determine if advanced bearings such as OxZr or ceramic can show improved performance in the second decade of implantation.
Collapse
Affiliation(s)
- Alberto V Carli
- Hospital for Special Surgery, 535 E 70th St., New York, 10021 NY, USA
| | - Anay R Patel
- Fondren Orthopedic Group, 7401 Main St., Houston, 77030 TX, USA
| | - Michael B Cross
- Hospital for Special Surgery, 535 E 70th St., New York, 10021 NY, USA
| | - David J Mayman
- Hospital for Special Surgery, 535 E 70th St., New York, 10021 NY, USA
| | - Kaitlin M Carroll
- Hospital for Special Surgery, 535 E 70th St., New York, 10021 NY, USA
| | - Paul M Pellicci
- Hospital for Special Surgery, 535 E 70th St., New York, 10021 NY, USA
| | - Seth A Jerabek
- Hospital for Special Surgery, 535 E 70th St., New York, 10021 NY, USA
| |
Collapse
|
23
|
Malahias MA, De Martino I, Gu A, Baral E, Wright TM, Sculco PK. Complete wear-through of a metal-backed acetabular cup in an ambulatory patient. Arthroplast Today 2019; 5:394-400. [PMID: 31886378 PMCID: PMC6920715 DOI: 10.1016/j.artd.2019.09.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 09/17/2019] [Accepted: 09/27/2019] [Indexed: 01/20/2023] Open
Abstract
We present a rare case of a patient who presented with complete and rapid wear-through of a ceramic femoral head through a polyethylene liner and titanium acetabular cup. In addition, this patient exhibited significantly elevated serum titanium ion levels, which may serve as a marker of severe metallosis in cases where the preoperative plain radiographs underestimate signs of periarticular metal debris. The unique findings of this case include the rapid (less than 1 year time) wear-through of the femoral head in interval radiographs and the dramatic progression of metallosis and pelvic and femoral osteolysis that required both component revision. In addition, the markedly elevated titanium levels secondary to cup wear-through are also of interest and demonstrate a systemic manifestation of abrasive wear of a titanium alloy component.
Collapse
Affiliation(s)
- Michael-Alexander Malahias
- Department of Orthopaedic Surgery, Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | - Ivan De Martino
- Department of Orthopaedic Surgery, Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | - Alex Gu
- Department of Orthopaedic Surgery, Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | - Elexis Baral
- Department of Biomechanics, Hospital for Special Surgery, New York, NY, USA
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, NY, USA
| | - Peter K Sculco
- Department of Orthopaedic Surgery, Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
24
|
[Total hip arthroplasty in young patients : Bearings and custom-made prostheses]. DER ORTHOPADE 2019; 48:292-299. [PMID: 30737518 DOI: 10.1007/s00132-019-03692-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
BACKGROUND Carefully and correctly implanted components are the prerequisite for the lifespan of a prosthesis. Whether higher levels of activity lead to prior failure of total hip arthroplasty in young patients is controversially discussed. The right choice of bearings is still of great relevance. BEARINGS Ceramic-on-ceramic as well as polyethylene-on-ceramic bearings achieve comparable results, although ceramic-on-ceramic bearings should be avoided in patients with high demands on their range of motion. Polyethylene-on-metal bearings also show good clinical results, if corrosion between head and stem is absent. Metal-on-metal bearings lead to adverse systemic effects due to metal wear and should be implanted in individual cases only, e. g. as hip resurfacing. Alternative bearings have to give proof of effectivity first. Custom-made prostheses constitute an option for young patients with special conditions of hip anatomy. Planning and study results of these prostheses are elucidated in this review article.
Collapse
|
25
|
Femoral Head Penetration Rates of Second-Generation Sequentially Annealed Highly Cross-Linked Polyethylene at Minimum Five Years. J Arthroplasty 2019; 34:781-788. [PMID: 30609952 DOI: 10.1016/j.arth.2018.12.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 11/19/2018] [Accepted: 12/04/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Highly cross-linked polyethylene (HXLPE) liners in total hip arthroplasty (THA) have demonstrated decreased wear rates, resilience to cup orientation, and reduced osteolysis compared to conventional polyethylene. Sequential irradiation and annealing below the melting temperature is unique compared to most HXLPE which is irradiated and remelted. This study purpose is to provide minimum 5-year femoral head penetration rates of sequentially annealed HXLPE in primary THA. METHODS A retrospective review of a prospectively collected database identified 198 consecutive, cementless primary THAs utilizing sequentially annealed HXLPE (X3; Stryker, Mahwah, NJ). Operative technique was standardized. Radiographs were analyzed utilizing the Martell method with minimum 5-year and 1-year radiographs as baseline to minimize the initial bedding-in period. RESULTS Seventy-seven hips with minimum 5-year follow-up were analyzed. Mean steady state linear and volumetric head penetration rates were 0.095 mm/y and 76 mm3/y, respectively. Volumetric head penetration was significantly less for 32-mm compared to 36-mm (P = .028). In addition, less head penetration was observed for ceramic 32-mm heads at nearly half the rate compared to cobalt-chromium 36-mm heads (P ≥ .092). No correlations existed between penetration rates and age, body mass index, University of California Los Angeles Activity Level, polyethylene thickness, cup inclination, or anteversion (P ≥ .10). No radiographic osteolysis was observed. CONCLUSION Surprisingly, linear head penetration rates of sequentially annealed HXLPE were nearly identical to the osteolysis threshold for conventional polyethylene and greater than reports of irradiated and remelted HXLPE. Furthermore, these data corroborate reports that HXLPE is resilient to cup orientation and demographic variables. Longer term follow-up is recommended.
Collapse
|
26
|
Abstract
Total hip arthroplasty (THA) is widely considered one of the most successful surgical procedures in orthopaedics. It is associated with high satisfaction rates and significant improvements in quality of life following surgery. On the other hand, the main cause of late revision is osteolysis and wear, often a result of failure of bearing surfaces.Currently, several options are available to the surgeon when choosing the bearing surface in THA (ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoPE), metal-on-polyethylene (MoPE)), each with advantages and drawbacks.Very few studies have directly compared the various combinations of bearings at long-term follow-up. Randomized controlled trials show similar short- to mid-term survivorship among the best performing bearing surfaces (CoC, CoXLPE and MoXLPE). Selection of the bearing surface is often 'experience-based' rather than 'evidence-based'.The aim of this paper is therefore to evaluate the main advantages and drawbacks of various types of tribology in THA, while providing practical suggestions for the surgeon on the most suitable bearing surface option for each patient. Cite this article: EFORT Open Rev 2018;3 DOI: 10.1302/2058-5241.3.180300.
Collapse
Affiliation(s)
- Luigi Zagra
- Hip Department, IRCCS Istituto Ortopedico Galeazzi, Italy
| | | |
Collapse
|