• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4640998)   Today's Articles (2091)   Subscriber (50401)
For: Deuse T, Erben RG, Ikeno F, Behnisch B, Boeger R, Connolly AJ, Reichenspurner H, Bergow C, Pelletier MP, Robbins RC, Schrepfer S. Introducing the first polymer-free leflunomide eluting stent. Atherosclerosis 2008;200:126-34. [PMID: 18295768 DOI: 10.1016/j.atherosclerosis.2007.12.055] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2007] [Accepted: 12/27/2007] [Indexed: 11/29/2022]
Number Cited by Other Article(s)
1
Moradi MR, Salahinejad E, Sharifi E, Tayebi L. Controlled drug delivery from chitosan-coated heparin-loaded nanopores anodically grown on nitinol shape-memory alloy. Carbohydr Polym 2023;314:120961. [PMID: 37173015 PMCID: PMC10585653 DOI: 10.1016/j.carbpol.2023.120961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 04/12/2023] [Accepted: 04/24/2023] [Indexed: 05/15/2023]
2
Kommineni N, Saka R, Khan W, Domb AJ. Non-polymer drug-eluting coronary stents. Drug Deliv Transl Res 2018;8:903-917. [PMID: 28799125 DOI: 10.1007/s13346-017-0414-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
3
Bagheri M, Mohammadi M, Steele TW, Ramezani M. Nanomaterial coatings applied on stent surfaces. Nanomedicine (Lond) 2017;11:1309-26. [PMID: 27111467 DOI: 10.2217/nnm-2015-0007] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]  Open
4
Roopmani P, Sethuraman S, Satheesh S, Maheswari Krishnan U. The metamorphosis of vascular stents: passive structures to smart devices. RSC Adv 2016. [DOI: 10.1039/c5ra19109b] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]  Open
5
Chen W, Habraken TCJ, Hennink WE, Kok RJ. Polymer-Free Drug-Eluting Stents: An Overview of Coating Strategies and Comparison with Polymer-Coated Drug-Eluting Stents. Bioconjug Chem 2015;26:1277-88. [PMID: 26041505 DOI: 10.1021/acs.bioconjchem.5b00192] [Citation(s) in RCA: 56] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
6
Foin N, Gutiérrez-Chico JL, Nakatani S, Torii R, Bourantas CV, Sen S, Nijjer S, Petraco R, Kousera C, Ghione M, Onuma Y, Garcia-Garcia HM, Francis DP, Wong P, Di Mario C, Davies JE, Serruys PW. Incomplete Stent Apposition Causes High Shear Flow Disturbances and Delay in Neointimal Coverage as a Function of Strut to Wall Detachment Distance. Circ Cardiovasc Interv 2014;7:180-9. [DOI: 10.1161/circinterventions.113.000931] [Citation(s) in RCA: 163] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
7
Hua X, Deuse T, Michelakis ED, Haromy A, Tsao PS, Maegdefessel L, Erben RG, Bergow C, Behnisch BB, Reichenspurner H, Robbins RC, Schrepfer S. Human internal mammary artery (IMA) transplantation and stenting: a human model to study the development of in-stent restenosis. J Vis Exp 2012:e3663. [PMID: 22617624 DOI: 10.3791/3663] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]  Open
8
Sheehy A, Gutiérrez-Chico JL, Diletti R, Oberhauser JP, Glauser T, Harrington J, Kossuth MB, Rapoza RJ, Onuma Y, Serruys PW. In vivo characterisation of bioresorbable vascular scaffold strut interfaces using optical coherence tomography with Gaussian line spread function analysis. EUROINTERVENTION 2012;7:1227-35. [DOI: 10.4244/eijv7i10a195] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
9
Lei L, Guo SR, Chen WL, Rong HJ, Lu F. Stents as a platform for drug delivery. Expert Opin Drug Deliv 2011;8:813-31. [DOI: 10.1517/17425247.2011.572068] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
10
Martinez AW, Chaikof EL. Microfabrication and nanotechnology in stent design. WILEY INTERDISCIPLINARY REVIEWS. NANOMEDICINE AND NANOBIOTECHNOLOGY 2011;3:256-68. [PMID: 21462356 PMCID: PMC3480085 DOI: 10.1002/wnan.123] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
11
Deuse T, Koyanagi T, Erben RG, Hua X, Velden J, Ikeno F, Reichenspurner H, Robbins RC, Mochly-Rosen D, Schrepfer S. Sustained inhibition of epsilon protein kinase C inhibits vascular restenosis after balloon injury and stenting. Circulation 2010;122:S170-8. [PMID: 20837910 DOI: 10.1161/circulationaha.109.927640] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
12
Uchida Y, Uchida Y. Angioscopic Evaluation of Neointimal Coverage of Coronary Stents. CURRENT CARDIOVASCULAR IMAGING REPORTS 2010;3:317-323. [PMID: 20835382 PMCID: PMC2927685 DOI: 10.1007/s12410-010-9039-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
13
Hamada N, Miyata M, Eto H, Shirasawa T, Akasaki Y, Nagaki A, Tei C. Tacrolimus-eluting stent inhibits neointimal hyperplasia via calcineurin/NFAT signaling in porcine coronary artery model. Atherosclerosis 2010;208:97-103. [PMID: 19682688 DOI: 10.1016/j.atherosclerosis.2009.07.040] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2008] [Revised: 07/08/2009] [Accepted: 07/15/2009] [Indexed: 10/20/2022]
PrevPage 1 of 1 1Next