1
|
Osama L, Handal HT, El-Sayed SAM, Elzayat EM, Mabrouk M. Fabrication and Optimisation of Alumina Nanoporous Membranes for Drug Delivery Applications: A Comparative Study. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:1078. [PMID: 38998683 PMCID: PMC11243695 DOI: 10.3390/nano14131078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Revised: 06/10/2024] [Accepted: 06/17/2024] [Indexed: 07/14/2024]
Abstract
Neurodegenerative disorders cause most physical and mental disabilities, and therefore require effective treatment. The blood-brain barrier (BBB) prevents drug molecules from crossing from the blood to the brain, making brain drug delivery difficult. Implantable devices could provide sustained and regulated medication to solve this problem. Two electrolytes (0.3 M oxalic acid and 0.3 M sulphuric acid) were used to anodise Al2O3 nanoporous membranes, followed by a third anodisation in concentrated H2SO4 to separate the through-hole membranes from the aluminium substrate. FTIR, AFM, and SEM/EDX were used to characterise the membranes' structure and morphology. The effects of the anodisation time and electrolyte type on the AAO layer pore density, diameter, interpore distance, and thickness were examined. As a model drug for neurodegenerative disorders, donepezil hydrochloride (DHC) was loaded onto thin alumina nanoporous membranes. The DHC release profiles were characterised at two concentrations using a UV-Vis spectrophotometer. Oxalic acid membranes demonstrated an average pore diameter of 39.6-32.5 nm, which was two times larger than sulphuric acid membranes (22.6-19.7 nm). After increasing the anodisation time from 3 to 5 h, all of the membranes showed a reduction in pore diameter that was stable regardless of the electrolyte type or period. Drug release from oxalic acid-fabricated membranes was controlled and sustained for over 2 weeks. Thus, nanoporous membranes as implantable drug delivery systems could improve neurodegenerative disease treatment.
Collapse
Affiliation(s)
- Lamyaa Osama
- Refractories, Ceramics and Building Materials Department, National Research Center, 33El Bohouth St. (Former EL Tahrir St.), Dokki, Giza P.O. Box 12622, Egypt
| | - Hala T Handal
- Inorganic Chemistry Department, National Research Center, Cairo P.O. Box 12622, Egypt
| | - Sara A M El-Sayed
- Refractories, Ceramics and Building Materials Department, National Research Center, 33El Bohouth St. (Former EL Tahrir St.), Dokki, Giza P.O. Box 12622, Egypt
| | - Emad M Elzayat
- Biotechnology Department, Faculty of Science, Cairo University, Giza P.O. Box 12613, Egypt
| | - Mostafa Mabrouk
- Refractories, Ceramics and Building Materials Department, National Research Center, 33El Bohouth St. (Former EL Tahrir St.), Dokki, Giza P.O. Box 12622, Egypt
- Academy of Scientific Research and Technology (ASRT), Cairo P.O. Box 11516, Egypt
| |
Collapse
|
2
|
Gao Y, Zhong M, Yu J, Zhao Z, Yu C, Yu Q, Yao F, Li J, Zhang H. Large-Scale Fabrication of Freestanding Polymer Ultrathin Porous Membranes for Transparent Transwell Coculture Systems. ACS NANO 2024; 18:8168-8179. [PMID: 38437515 DOI: 10.1021/acsnano.3c11946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2024]
Abstract
Advancements in cell coculture systems with porous membranes have facilitated the simulation of human-like in vitro microenvironments for diverse biomedical applications. However, conventional Transwell membranes face limitations in low porosity (ca. 6%) and optical opacity due to their large thickness (ca. 10 μm). In this study, we demonstrated a one-step, large-scale fabrication of freestanding polymer ultrathin porous (PUP) membranes with thicknesses of hundreds of nanometers. PUP membranes were produced by using a gap-controlled bar-coating process combined with polymer blend phase separation. They are 20 times thinner than Transwell membranes, possessing 3-fold higher porosity and exhibiting high transparency. These membranes demonstrate outstanding molecular permeability and significantly reduce the cell-cell distance, thereby facilitating efficient signal exchange pathways between cells. This research enables the establishment of a cutting-edge in vitro cell coculture system, enhancing optical transparency, and streamlining the large-scale manufacturing of porous membranes.
Collapse
Affiliation(s)
- Yi Gao
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China
| | - Mengyao Zhong
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China
| | - Jiajun Yu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China
| | - Zhongming Zhao
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China
| | - Chaojie Yu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China
| | - Qingyu Yu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China
- Tianjin Key Laboratory of Biomedical Materials, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin 300192, China
| | - Fanglian Yao
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China
- Frontiers Science Center for Synthetic Biology and Key Laboratory of Systems Bioengineering, Ministry of Education, Tianjin University, Tianjin 300350, China
| | - Junjie Li
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China
- Frontiers Science Center for Synthetic Biology and Key Laboratory of Systems Bioengineering, Ministry of Education, Tianjin University, Tianjin 300350, China
| | - Hong Zhang
- School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China
- Frontiers Science Center for Synthetic Biology and Key Laboratory of Systems Bioengineering, Ministry of Education, Tianjin University, Tianjin 300350, China
| |
Collapse
|
3
|
Mancinelli E, Zushi N, Takuma M, Cheng Chau CC, Parpas G, Fujie T, Pensabene V. Porous Polymeric Nanofilms for Recreating the Basement Membrane in an Endothelial Barrier-on-Chip. ACS APPLIED MATERIALS & INTERFACES 2024; 16:13006-13017. [PMID: 38414331 PMCID: PMC10941076 DOI: 10.1021/acsami.3c16134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 01/25/2024] [Accepted: 01/26/2024] [Indexed: 02/29/2024]
Abstract
Organs-on-chips (OoCs) support an organotypic human cell culture in vitro. Precise representation of basement membranes (BMs) is critical for mimicking physiological functions of tissue interfaces. Artificial membranes in polyester (PES) and polycarbonate (PC) commonly used in in vitro models and OoCs do not replicate the characteristics of the natural BMs, such as submicrometric thickness, selective permeability, and elasticity. This study introduces porous poly(d,l-lactic acid) (PDLLA) nanofilms for replicating BMs in in vitro models and demonstrates their integration into microfluidic chips. Using roll-to-roll gravure coating and polymer phase separation, we fabricated transparent ∼200 nm thick PDLLA films. These nanofilms are 60 times thinner and 27 times more elastic than PES membranes and show uniformly distributed pores of controlled diameter (0.4 to 1.6 μm), which favor cell compartmentalization and exchange of large water-soluble molecules. Human umbilical vein endothelial cells (HUVECs) on PDLLA nanofilms stretched across microchannels exhibited 97% viability, enhanced adhesion, and a higher proliferation rate compared to their performance on PES membranes and glass substrates. After 5 days of culture, HUVECs formed a functional barrier on suspended PDLLA nanofilms, confirmed by a more than 10-fold increase in transendothelial electrical resistance and blocked 150 kDa dextran diffusion. When integrated between two microfluidic channels and exposed to physiological shear stress, despite their ultrathin thickness, PDLLA nanofilms upheld their integrity and efficiently maintained separation of the channels. The successful formation of an adherent endothelium and the coculture of HUVECs and human astrocytes on either side of the suspended nanofilm validate it as an artificial BM for OoCs. Its submicrometric thickness guarantees intimate contact, a key feature to mimic the blood-brain barrier and to study paracrine signaling between the two cell types. In summary, porous PDLLA nanofilms hold the potential for improving the accuracy and physiological relevance of the OoC as in vitro models and drug discovery tools.
Collapse
Affiliation(s)
- Elena Mancinelli
- School
of Electronic and Electrical Engineering and Pollard Institute, University of Leeds, Leeds LS2 9JT, United Kingdom
- Bragg
Centre for Materials Research, University
of Leeds, Leeds LS2 9JT, United Kingdom
| | - Nanami Zushi
- School
of Life Science and Technology, Tokyo Institute
of Technology, B-50, Nagatsuta-cho, Midori-ku, Yokohama 226-8501, Japan
| | - Megumi Takuma
- School
of Life Science and Technology, Tokyo Institute
of Technology, B-50, Nagatsuta-cho, Midori-ku, Yokohama 226-8501, Japan
| | - Chalmers Chi Cheng Chau
- School
of Electronic and Electrical Engineering and Pollard Institute, University of Leeds, Leeds LS2 9JT, United Kingdom
- Bragg
Centre for Materials Research, University
of Leeds, Leeds LS2 9JT, United Kingdom
- School
of Molecular and Cellular Biology and Astbury Centre for Structural
Molecular Biology, University of Leeds, Leeds LS2 9JT, United Kingdom
| | - George Parpas
- School
of Electronic and Electrical Engineering and Pollard Institute, University of Leeds, Leeds LS2 9JT, United Kingdom
- Bragg
Centre for Materials Research, University
of Leeds, Leeds LS2 9JT, United Kingdom
- Leeds
Institute of Biomedical and Clinical Sciences, University of Leeds, Leeds LS2 9JT, United
Kingdom
| | - Toshinori Fujie
- School
of Life Science and Technology, Tokyo Institute
of Technology, B-50, Nagatsuta-cho, Midori-ku, Yokohama 226-8501, Japan
- Living Systems
Materialogy (LiSM) Research Group, International Research Frontiers
Initiative (IRFI), Tokyo Institute of Technology, R3-23, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8503, Japan
| | - Virginia Pensabene
- School
of Electronic and Electrical Engineering and Pollard Institute, University of Leeds, Leeds LS2 9JT, United Kingdom
- Bragg
Centre for Materials Research, University
of Leeds, Leeds LS2 9JT, United Kingdom
- Faculty
of Medicine and Health, Leeds Institute of Medical Research at St
James’s University Hospital, University of Leeds, Leeds LS2 9JT, United Kingdom
| |
Collapse
|
4
|
Yuan T, Shen L, Dini D. Porosity-permeability tensor relationship of closely and randomly packed fibrous biomaterials and biological tissues: Application to the brain white matter. Acta Biomater 2024; 173:123-134. [PMID: 37979635 DOI: 10.1016/j.actbio.2023.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 10/09/2023] [Accepted: 11/06/2023] [Indexed: 11/20/2023]
Abstract
The constitutive model for the porosity-permeability relationship is a powerful tool to estimate and design the transport properties of porous materials, which has attracted significant attention for the advancement of novel materials. However, in comparison with other materials, biomaterials, especially natural and artificial tissues, have more complex microstructures e.g. high anisotropy, high randomness of cell/fibre dimensions/position and very low porosity. Consequently, a reliable microstructure-permeability relationship of fibrous biomaterials has proven elusive. To fill this gap, we start a mathematical derivation from the fundamental brain white matter (WM) formed by nerve fibres. This is augmented by a numerical characterisation and experimental validations to obtain an anisotropic permeability tensor of the brain WM as a function of the tissue porosity. A versatile microstructure generation software (MicroFiM) for fibrous biomaterial with complex microstructure and low porosity was built accordingly and made freely accessible here. Moreover, we propose an anisotropic poro-hyperelastic model enhanced by the newly defined porosity-permeability tensor relationship which precisely captures the tissues macro-scale permeability changes due to the microstructural deformation in an infusion scenario. The constitutive model, theories and protocols established in this study will both provide improved design strategies to tailor the transport properties of fibrous biomaterials and enable the non-invasive characterisation of the transport properties of biological tissues. This will lead to the provision of better patient-specific medical treatments, such as drug delivery. STATEMENT OF SIGNIFICANCE: Due to the microstructural complexity, a reliable microstructure-permeability relationship of fibrous biomaterials has proven elusive, which hinders our way of tuning the fluid transport property of the biomaterials by directly programming their microstructure. The same problem hinders non-invasive characterisations of fluid transport properties in biological tissues, which can significantly improve the efficiency of treatments e.g. drug delivery, directly from the tissues accessible microstructural information, e.g. porosity. Here, we developed a validated mathematical formulation to link the random microstructure to a fibrous material's macroscale permeability tensor. This will advance our capability to design complex biomaterials and make it possible to non-invasively characterise the permeability of living tissues for precise treatment planning. The newly established theory and protocol can be easily adapted to various types of fibrous biomaterials.
Collapse
Affiliation(s)
- Tian Yuan
- Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK.
| | - Li Shen
- Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK
| | - Daniele Dini
- Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK.
| |
Collapse
|
5
|
Huang SH, Parandhaman M, Farnia S, Kim J, Amemiya S. Nanoelectrochemistry at liquid/liquid interfaces for analytical, biological, and material applications. Chem Commun (Camb) 2023; 59:9575-9590. [PMID: 37458703 PMCID: PMC10416082 DOI: 10.1039/d3cc01982a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/04/2023]
Abstract
Herein, we feature our recent efforts toward the development and application of nanoelectrochemistry at liquid/liquid interfaces, which are also known as interfaces between two immiscible electrolyte solutions (ITIES). Nanopipets, nanopores, and nanoemulsions are developed to create the nanoscale ITIES for the quantitative electrochemical measurement of ion transfer, electron transfer, and molecular transport across the interface. The nanoscale ITIES serves as an electrochemical nanosensor to enable the selective detection of various ions and molecules as well as high-resolution chemical imaging based on scanning electrochemical microscopy. The powerful nanoelectroanalytical methods will be useful for biological and material applications as illustrated by in situ studies of solid-state nanopores, nuclear pore complexes, living bacteria, and advanced nanoemulsions. These studies provide unprecedented insights into the chemical reactivity of important biological and material systems even at the single nanostructure level.
Collapse
Affiliation(s)
- Siao-Han Huang
- Department of Chemistry, University of Pittsburgh, Pittsburgh, PA, 15260, USA.
| | | | - Solaleh Farnia
- Department of Chemistry, University of Rhode Island, Kingston, RI, 02881, USA.
| | - Jiyeon Kim
- Department of Chemistry, University of Rhode Island, Kingston, RI, 02881, USA.
| | - Shigeru Amemiya
- Department of Chemistry, University of Pittsburgh, Pittsburgh, PA, 15260, USA.
| |
Collapse
|
6
|
Advances in cell coculture membranes recapitulating in vivo microenvironments. Trends Biotechnol 2023; 41:214-227. [PMID: 36030108 DOI: 10.1016/j.tibtech.2022.07.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 07/05/2022] [Accepted: 07/25/2022] [Indexed: 01/24/2023]
Abstract
Porous membranes play a critical role in in vitro heterogeneous cell coculture systems because they recapitulate the in vivo microenvironment to mediate physical and biochemical crosstalk between cells. While the conventionally available Transwell® system has been widely used for heterogeneous cell coculture, there are drawbacks to precise control over cell-cell interactions and separation for implantation. The size and numbers of the pores and the thickness of the porous membranes are crucial in determining the efficiency of paracrine signaling and direct junctions between cocultured cells, and significantly impact on the performance of heterogeneous cell cultures. These opportunities and challenges have motivated the design of advanced coculture platforms through improvement of the structural and functional properties of porous membranes.
Collapse
|
7
|
Rothen-Rutishauser B, Gibb M, He R, Petri-Fink A, Sayes CM. Human lung cell models to study aerosol delivery - considerations for model design and development. Eur J Pharm Sci 2023; 180:106337. [PMID: 36410570 DOI: 10.1016/j.ejps.2022.106337] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 11/16/2022] [Accepted: 11/17/2022] [Indexed: 11/23/2022]
Abstract
Human lung tissue models range from simple monolayer cultures to more advanced three-dimensional co-cultures. Each model system can address the interactions of different types of aerosols and the choice of the model and the mode of aerosol exposure depends on the relevant scenario, such as adverse outcomes and endpoints of interest. This review focuses on the functional, as well as structural, aspects of lung tissue from the upper airway to the distal alveolar compartments as this information is relevant for the design of a model as well as how the aerosol properties determine the interfacial properties with the respiratory wall. The most important aspects on how to design lung models are summarized with a focus on (i) choice of appropriate scaffold, (ii) selection of cell types for healthy and diseased lung models, (iii) use of culture condition and assembly, (iv) aerosol exposure methods, and (v) endpoints and verification process. Finally, remaining challenges and future directions in this field are discussed.
Collapse
Affiliation(s)
- Barbara Rothen-Rutishauser
- BioNanomaterials, Adolphe Merkle Institute, University Fribourg, Chemin des Verdiers 4 CH-1700, Fribourg, Switzerland.
| | - Matthew Gibb
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798-7266, USA
| | - Ruiwen He
- BioNanomaterials, Adolphe Merkle Institute, University Fribourg, Chemin des Verdiers 4 CH-1700, Fribourg, Switzerland
| | - Alke Petri-Fink
- BioNanomaterials, Adolphe Merkle Institute, University Fribourg, Chemin des Verdiers 4 CH-1700, Fribourg, Switzerland
| | - Christie M Sayes
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798-7266, USA.
| |
Collapse
|
8
|
Wang Y, Duan Y, Tian F, Zhou Z, Liu Y, Wang W, Gao B, Tang Y. Ultrathin and handleable nanofibrous net as a novel biomimetic basement membrane material for endothelial barrier formation. Colloids Surf B Biointerfaces 2022; 219:112775. [PMID: 36108364 DOI: 10.1016/j.colsurfb.2022.112775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 08/08/2022] [Accepted: 08/13/2022] [Indexed: 11/24/2022]
Abstract
Many strategies have been adopted to develop porous membranes to reconstitute basement membrane in vitro, which play a key role in the development of in vitro biomimetic models. However, the development of an artificial basement membrane combines cytocompatibility and nano-thickness is still challenging. Herein, a monolayer nanofibrous net patch was fabricated by combining microfabrication and electrospinning as a biomimetic basement membrane material, which was demonstrated for endothelial barrier formation. The nanofibrous net patches with different fiber densities were obtained by controlling electrospinning time. The net was with high porosity and ultrathin thickness approximate to the diameter of nanofibers, which is comparable to that of the native basement membrane. The morphology, proliferation and cell-cell/cell-substrate interactions of endothelial cells on the nanofibrous nets were studied and compared with track-etched polycarbonate membrane and traditional multilayer nanofibers membrane. In addition, the results of TEER measurement and permeability test demonstrated that the endothelial barrier formed on the nanofibrous net patch displayed stronger barrier integrity and function. Therefore, the proposed nanofibrous net patch shows great potential as a novel biomimetic basement membrane, which is promising to be applied for in vitro tissue mimetic applications.
Collapse
Affiliation(s)
- Yaqi Wang
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China
| | - Yujie Duan
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China
| | - Feng Tian
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China
| | - Zehui Zhou
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China
| | - Yurong Liu
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China
| | - Wenlong Wang
- School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China
| | - Botao Gao
- Institute of Biological and Medical Engineering, Guangdong Academy of Sciences, Guangzhou 510632, China
| | - Yadong Tang
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China.
| |
Collapse
|
9
|
Sun M, Han K, Hu R, Liu D, Fu W, Liu W. Advances in Micro/Nanoporous Membranes for Biomedical Engineering. Adv Healthc Mater 2021; 10:e2001545. [PMID: 33511718 DOI: 10.1002/adhm.202001545] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 01/19/2021] [Indexed: 12/11/2022]
Abstract
Porous membrane materials at the micro/nanoscale have exhibited practical and potential value for extensive biological and medical applications associated with filtration and isolation, cell separation and sorting, micro-arrangement, in-vitro tissue reconstruction, high-throughput manipulation and analysis, and real-time sensing. Herein, an overview of technological development of micro/nanoporous membranes (M/N-PMs) is provided. Various membrane types and the progress documented in membrane fabrication techniques, including the electrochemical-etching, laser-based technology, microcontact printing, electron beam lithography, imprinting, capillary force lithography, spin coating, and microfluidic molding are described. Their key features, achievements, and limitations associated with micro/nanoporous membrane (M/N-PM) preparation are discussed. The recently popularized applications of M/N-PMs in biomedical engineering involving the separation of cells and biomolecules, bioparticle operations, biomimicking, micropatterning, bioassay, and biosensing are explored too. Finally, the challenges that need to be overcome for M/N-PM fabrication and future applications are highlighted.
Collapse
Affiliation(s)
- Meilin Sun
- School of Basic Medical Science Central South University Changsha Hunan 410013 China
| | - Kai Han
- School of Basic Medical Science Central South University Changsha Hunan 410013 China
| | - Rui Hu
- School of Basic Medical Science Central South University Changsha Hunan 410013 China
| | - Dan Liu
- School of Basic Medical Science Central South University Changsha Hunan 410013 China
| | - Wenzhu Fu
- School of Basic Medical Science Central South University Changsha Hunan 410013 China
| | - Wenming Liu
- School of Basic Medical Science Central South University Changsha Hunan 410013 China
| |
Collapse
|
10
|
Gholizadeh S, Allahyari Z, Carter R, Delgadillo LF, Blaquiere M, Nouguier-Morin F, Marchi N, Gaborski TR. Robust and Gradient Thickness Porous Membranes for In Vitro Modeling of Physiological Barriers. ADVANCED MATERIALS TECHNOLOGIES 2020; 5:2000474. [PMID: 33709013 PMCID: PMC7942760 DOI: 10.1002/admt.202000474] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Indexed: 05/06/2023]
Abstract
Porous membranes are fundamental elements for tissue-chip barrier and co-culture models. However, the exaggerated thickness of commonly available membranes may represent a stumbling block impeding a more accurate in vitro modeling. Existing techniques to fabricate membranes such as solvent cast, spin-coating, sputtering and PE-CVD result in uniform thickness films. Here, we developed a robust method to generate ultrathin porous parylene C (UPP) membranes not just with precise thicknesses down to 300 nm, but with variable gradients in thicknesses, while at the same time having porosities up to 25%. We also show surface etching and increased roughness lead to improved cell attachment. Next, we examined the mechanical properties of UPP membranes with varying porosity and thickness and fit our data to previously published models, which can help determine practical upper limits of porosity and lower limits of thickness. Lastly, we validate a straightforward approach allowing the successful integration of the UPP membranes into a prototyped 3D-printed scaffold, demonstrating mechanical robustness and allowing cell adhesion under varying flow conditions. Collectively, our results support the integration and the use of UPP membranes to examine cell-cell interaction in vitro.
Collapse
Affiliation(s)
- Shayan Gholizadeh
- Department of Microsystems Engineering, Rochester Institute of Technology, Rochester, NY, 14623, USA
| | - Zahra Allahyari
- Department of Microsystems Engineering, Rochester Institute of Technology, Rochester, NY, 14623, USA
| | - Robert Carter
- Department of Mechanical Engineering, Rochester Institute of Technology, Rochester, NY, 14623, USA
| | - Luis F Delgadillo
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14620, USA
| | - Marine Blaquiere
- Cerebrovascular and Glia Research, Institute of Functional Genomics (CNRS UMR5203, INSERM U1191, and University of Montpellier), Montpellier, 34094, France
| | - Frederic Nouguier-Morin
- Cerebrovascular and Glia Research, Institute of Functional Genomics (CNRS UMR5203, INSERM U1191, and University of Montpellier), Montpellier, 34094, France
| | - Nicola Marchi
- Cerebrovascular and Glia Research, Institute of Functional Genomics (CNRS UMR5203, INSERM U1191, and University of Montpellier), Montpellier, 34094, France
| | - Thomas R Gaborski
- Department of Microsystems Engineering, Rochester Institute of Technology, Rochester, NY, 14623, USA
| |
Collapse
|
11
|
Salminen AT, Allahyari Z, Gholizadeh S, McCloskey MC, Ajalik R, Cottle RN, Gaborski TR, McGrath JL. In vitro Studies of Transendothelial Migration for Biological and Drug Discovery. FRONTIERS IN MEDICAL TECHNOLOGY 2020; 2:600616. [PMID: 35047883 PMCID: PMC8757899 DOI: 10.3389/fmedt.2020.600616] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Accepted: 10/20/2020] [Indexed: 12/13/2022] Open
Abstract
Inflammatory diseases and cancer metastases lack concrete pharmaceuticals for their effective treatment despite great strides in advancing our understanding of disease progression. One feature of these disease pathogeneses that remains to be fully explored, both biologically and pharmaceutically, is the passage of cancer and immune cells from the blood to the underlying tissue in the process of extravasation. Regardless of migratory cell type, all steps in extravasation involve molecular interactions that serve as a rich landscape of targets for pharmaceutical inhibition or promotion. Transendothelial migration (TEM), or the migration of the cell through the vascular endothelium, is a particularly promising area of interest as it constitutes the final and most involved step in the extravasation cascade. While in vivo models of cancer metastasis and inflammatory diseases have contributed to our current understanding of TEM, the knowledge surrounding this phenomenon would be significantly lacking without the use of in vitro platforms. In addition to the ease of use, low cost, and high controllability, in vitro platforms permit the use of human cell lines to represent certain features of disease pathology better, as seen in the clinic. These benefits over traditional pre-clinical models for efficacy and toxicity testing are especially important in the modern pursuit of novel drug candidates. Here, we review the cellular and molecular events involved in leukocyte and cancer cell extravasation, with a keen focus on TEM, as discovered by seminal and progressive in vitro platforms. In vitro studies of TEM, specifically, showcase the great experimental progress at the lab bench and highlight the historical success of in vitro platforms for biological discovery. This success shows the potential for applying these platforms for pharmaceutical compound screening. In addition to immune and cancer cell TEM, we discuss the promise of hepatocyte transplantation, a process in which systemically delivered hepatocytes must transmigrate across the liver sinusoidal endothelium to successfully engraft and restore liver function. Lastly, we concisely summarize the evolving field of porous membranes for the study of TEM.
Collapse
Affiliation(s)
- Alec T. Salminen
- Biomedical Engineering, University of Rochester, Rochester, NY, United States
| | - Zahra Allahyari
- Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, United States
| | - Shayan Gholizadeh
- Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, United States
| | - Molly C. McCloskey
- Biomedical Engineering, University of Rochester, Rochester, NY, United States
| | - Raquel Ajalik
- Biomedical Engineering, University of Rochester, Rochester, NY, United States
| | - Renee N. Cottle
- Bioengineering, Clemson University, Clemson, SC, United States
| | - Thomas R. Gaborski
- Biomedical Engineering, University of Rochester, Rochester, NY, United States
- Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, United States
| | - James L. McGrath
- Biomedical Engineering, University of Rochester, Rochester, NY, United States
| |
Collapse
|
12
|
Khire TS, Salminen AT, Swamy H, Lucas KS, McCloskey MC, Ajalik RE, Chung HH, Gaborski TR, Waugh RE, Glading AJ, McGrath JL. Microvascular Mimetics for the Study of Leukocyte-Endothelial Interactions. Cell Mol Bioeng 2020; 13:125-139. [PMID: 32175026 DOI: 10.1007/s12195-020-00611-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Accepted: 01/24/2020] [Indexed: 02/06/2023] Open
Abstract
Introduction The pathophysiological increase in microvascular permeability plays a well-known role in the onset and progression of diseases like sepsis and atherosclerosis. However, how interactions between neutrophils and the endothelium alter vessel permeability is often debated. Methods In this study, we introduce a microfluidic, silicon-membrane enabled vascular mimetic (μSiM-MVM) for investigating the role of neutrophils in inflammation-associated microvascular permeability. In utilizing optically transparent silicon nanomembrane technology, we build on previous microvascular models by enabling in situ observations of neutrophil-endothelium interactions. To evaluate the effects of neutrophil transmigration on microvascular model permeability, we established and validated electrical (transendothelial electrical resistance and impedance) and small molecule permeability assays that allow for the in situ quantification of temporal changes in endothelium junctional integrity. Results Analysis of neutrophil-expressed β1 integrins revealed a prominent role of neutrophil transmigration and basement membrane interactions in increased microvascular permeability. By utilizing blocking antibodies specific to the β1 subunit, we found that the observed increase in microvascular permeability due to neutrophil transmigration is constrained when neutrophil-basement membrane interactions are blocked. Having demonstrated the value of in situ measurements of small molecule permeability, we then developed and validated a quantitative framework that can be used to interpret barrier permeability for comparisons to conventional Transwell™ values. Conclusions Overall, our results demonstrate the potential of the μSiM-MVM in elucidating mechanisms involved in the pathogenesis of inflammatory disease, and provide evidence for a role for neutrophils in inflammation-associated endothelial barrier disruption.
Collapse
Affiliation(s)
- Tejas S Khire
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627 USA
| | - Alec T Salminen
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627 USA
| | - Harsha Swamy
- Department of Pharmacology and Physiology, University of Rochester, Rochester, NY 14627 USA
| | - Kilean S Lucas
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627 USA
| | - Molly C McCloskey
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627 USA
| | - Raquel E Ajalik
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627 USA
| | - Henry H Chung
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY 14623 USA
| | - Thomas R Gaborski
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627 USA.,Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY 14623 USA
| | - Richard E Waugh
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627 USA
| | - Angela J Glading
- Department of Pharmacology and Physiology, University of Rochester, Rochester, NY 14627 USA
| | - James L McGrath
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627 USA
| |
Collapse
|
13
|
Hudecz D, Khire T, Chung HL, Adumeau L, Glavin D, Luke E, Nielsen MS, Dawson KA, McGrath JL, Yan Y. Ultrathin Silicon Membranes for in Situ Optical Analysis of Nanoparticle Translocation across a Human Blood-Brain Barrier Model. ACS NANO 2020; 14:1111-1122. [PMID: 31914314 PMCID: PMC7049097 DOI: 10.1021/acsnano.9b08870] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Here we present a blood-brain barrier (BBB) model that enables high-resolution imaging of nanoparticle (NP) interactions with endothelial cells and the capture of rare NP translocation events. The enabling technology is an ultrathin silicon nitride (SiN) membrane (0.5 μm pore size, 20% porosity, 400 nm thickness) integrated into a dual-chamber platform that facilitates imaging at low working distances (∼50 μm). The platform, the μSiM-BBB (microfluidic silicon membrane-BBB), features human brain endothelial cells and primary astrocytes grown on opposite sides of the membrane. The human brain endothelial cells form tight junctions on the ultrathin membranes and exhibit a significantly higher resistance to FITC-dextran diffusion than commercial membranes. The enhanced optical properties of the SiN membrane allow high-resolution live-cell imaging of three types of NPs, namely, 40 nm PS-COOH, 100 nm PS-COOH, and apolipoprotein E-conjugated 100 nm SiO2, interacting with the BBB. Despite the excellent barrier properties of the endothelial layer, we are able to document rare NP translocation events of NPs localized to lysosomal compartments of astrocytes on the "brain side" of the device. Although the translocation is always low, our data suggest that size and targeting ligand are important parameters for NP translocation across the BBB. As a platform that enables the detection of rare transmission across tight BBB layers, the μSiM-BBB is an important tool for the design of nanoparticle-based delivery of drugs to the central nervous system.
Collapse
Affiliation(s)
- Diána Hudecz
- Centre for BioNano Interactions, School of Chemistry, University College Dublin, Belfield, Dublin 4, Ireland
- Present address: Department of Biomedicine, Faculty of Health, Aarhus University, Høegh-Guldbergs Gade 10, 8000 Aarhus, Denmark
| | - Tejas Khire
- Department of Biomedical Engineering, University of Rochester, Rochester, New York 14627, United States
| | - Hung Li Chung
- Department of Biomedical Engineering, University of Rochester, Rochester, New York 14627, United States
| | - Laurent Adumeau
- Centre for BioNano Interactions, School of Chemistry, University College Dublin, Belfield, Dublin 4, Ireland
| | - Dale Glavin
- Department of Biomedical Engineering, University of Rochester, Rochester, New York 14627, United States
| | - Emma Luke
- Department of Biomedical Engineering, University of Rochester, Rochester, New York 14627, United States
| | - Morten S. Nielsen
- Department of Biomedicine, Faculty of Health, Aarhus University, Høegh-Guldbergs Gade 10, 8000 Aarhus, Denmark
- Lundbeck Foundation, Research Initiative on Brain Barriers and Drug Delivery, Scherfigsvej 7, 2100 Copenhagen, Denmark
| | - Kenneth A. Dawson
- Centre for BioNano Interactions, School of Chemistry, University College Dublin, Belfield, Dublin 4, Ireland
| | - James L. McGrath
- Department of Biomedical Engineering, University of Rochester, Rochester, New York 14627, United States
| | - Yan Yan
- Centre for BioNano Interactions, School of Chemistry, University College Dublin, Belfield, Dublin 4, Ireland
- School of Biomolecular and Biomedical Science, UCD Conway Institute of Biomolecular and Biomedical Research, University College Dublin, Belfield, Dublin 4, Ireland
| |
Collapse
|
14
|
Song SY, Yoo J, Go S, Hong J, Sohn HS, Lee JR, Kang M, Jeong GJ, Ryu S, Kim SHL, Hwang NS, Char K, Kim BS. Cardiac-mimetic cell-culture system for direct cardiac reprogramming. Theranostics 2019; 9:6734-6744. [PMID: 31660065 PMCID: PMC6815967 DOI: 10.7150/thno.35574] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 08/05/2019] [Indexed: 12/19/2022] Open
Abstract
Rationale: Cardiovascular diseases often cause substantial heart damage and even heart failure due to the limited regenerative capacity of adult cardiomyocytes. The direct cardiac reprogramming of fibroblasts could be a promising therapeutic option for these patients. Although exogenous transcriptional factors can induce direct cardiac reprogramming, the reprogramming efficiency is too low to be used clinically. Herein, we introduce a cardiac-mimetic cell-culture system that resembles the microenvironment in the heart and provides interactions with cardiomyocytes and electrical cues to the cultured fibroblasts for direct cardiac reprogramming. Methods: Nano-thin and nano-porous membranes and heart like electric stimulus were used in the cardiac-mimetic cell-culture system. The human neonatal dermal fibroblasts containing cardiac transcription factors were plated on the membrane and cultured with the murine cardiomyocyte in the presence of the electric stimulus. The reprogramming efficiency was evaluated by qRT-PCR and immunocytochemistry. Results: Nano-thin and nano-porous membranes in the culture system facilitated interactions between fibroblasts and cardiomyocytes in coculture. The cellular interactions and electric stimulation supplied by the culture system dramatically enhanced the cardiac reprogramming efficiency of cardiac-specific transcriptional factor-transfected fibroblasts. Conclusion: The cardiac-mimetic culture system may serve as an effective tool for producing a feasible number of reprogrammed cardiomyocytes from fibroblasts.
Collapse
|
15
|
Belessiotis-Richards A, Higgins SG, Butterworth B, Stevens MM, Alexander-Katz A. Single-Nanometer Changes in Nanopore Geometry Influence Curvature, Local Properties, and Protein Localization in Membrane Simulations. NANO LETTERS 2019; 19:4770-4778. [PMID: 31241342 DOI: 10.1021/acs.nanolett.9b01990] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Nanoporous surfaces are used in many applications in intracellular sensing and drug delivery. However, the effects of such nanostructures on cell membrane properties are still far from understood. Here, we use coarse-grained molecular dynamics simulations to show that nanoporous substrates can stimulate membrane-curvature effects and that this curvature-sensing effect is much more sensitive than previously thought. We define a series of design parameters for inducing a nanoscale membrane curvature and show that nanopore taper plays a key role in membrane deformation, elucidating a previously unexplored fabrication parameter applicable to many nanostructured biomaterials. We report significant changes in the membrane area per lipid and thickness at regions of curvature. Finally, we demonstrate that regions of the nanopore-induced membrane curvature act as local hotspots for an increased bioactivity. We show spontaneous binding and localization of the epsin N-terminal homology (ENTH) domain to the regions of curvature. Understanding this interplay between the membrane curvature and nanoporosity at the biointerface helps both explain recent biological results and suggests a pathway for developing the next generation of cell-active substrates.
Collapse
Affiliation(s)
- Alexis Belessiotis-Richards
- Department of Materials , Imperial College London , Exhibition Road , London SW7 2AZ , United Kingdom
- Department of Bioengineering , Imperial College London , Exhibition Road , London SW7 2AZ , United Kingdom
- Institute of Biomedical Engineering , Imperial College London , Exhibition Road , London SW7 2AZ , United Kingdom
| | - Stuart G Higgins
- Department of Materials , Imperial College London , Exhibition Road , London SW7 2AZ , United Kingdom
- Department of Bioengineering , Imperial College London , Exhibition Road , London SW7 2AZ , United Kingdom
- Institute of Biomedical Engineering , Imperial College London , Exhibition Road , London SW7 2AZ , United Kingdom
| | - Ben Butterworth
- Department of Materials , Imperial College London , Exhibition Road , London SW7 2AZ , United Kingdom
| | - Molly M Stevens
- Department of Materials , Imperial College London , Exhibition Road , London SW7 2AZ , United Kingdom
- Department of Bioengineering , Imperial College London , Exhibition Road , London SW7 2AZ , United Kingdom
- Institute of Biomedical Engineering , Imperial College London , Exhibition Road , London SW7 2AZ , United Kingdom
| | - Alfredo Alexander-Katz
- Department of Materials Science & Engineering , Massachusetts Institute of Technology , Cambridge , Massachusetts 02139 , United States
| |
Collapse
|
16
|
Iqbal Z, Kim S, Moyer J, Moses W, Abada E, Wright N, Kim EJ, Park J, Fissell WH, Vartanian S, Roy S. In vitro and in vivo hemocompatibility assessment of ultrathin sulfobetaine polymer coatings for silicon-based implants. J Biomater Appl 2019; 34:297-312. [PMID: 30862226 DOI: 10.1177/0885328219831044] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Zohora Iqbal
- 1 Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, USA
| | - Steven Kim
- 1 Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, USA
| | - Jarrett Moyer
- 1 Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, USA
| | - Willieford Moses
- 1 Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, USA
| | - Emily Abada
- 1 Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, USA
| | - Nathan Wright
- 1 Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, USA
| | - Eun Jung Kim
- 1 Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, USA
| | - Jaehyun Park
- 1 Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, USA
| | | | - Shant Vartanian
- 3 Division of Vascular & Endovascular Surgery, University of California, San Francisco, USA
| | - Shuvo Roy
- 1 Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, USA
| |
Collapse
|
17
|
Salminen AT, Zhang J, Madejski GR, Khire TS, Waugh RE, McGrath JL, Gaborski TR. Ultrathin Dual-Scale Nano- and Microporous Membranes for Vascular Transmigration Models. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1804111. [PMID: 30632319 PMCID: PMC6530565 DOI: 10.1002/smll.201804111] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Revised: 11/26/2018] [Indexed: 05/21/2023]
Abstract
Selective cellular transmigration across the microvascular endothelium regulates innate and adaptive immune responses, stem cell localization, and cancer cell metastasis. Integration of traditional microporous membranes into microfluidic vascular models permits the rapid assay of transmigration events but suffers from poor reproduction of the cell permeable basement membrane. Current microporous membranes in these systems have large nonporous regions between micropores that inhibit cell communication and nutrient exchange on the basolateral surface reducing their physiological relevance. Here, the use of 100 nm thick continuously nanoporous silicon nitride membranes as a base substrate for lithographic fabrication of 3 µm pores is presented, resulting in a highly porous (≈30%), dual-scale nano- and microporous membrane for use in an improved vascular transmigration model. Ultrathin membranes are patterned using a precision laser writer for cost-effective, rapid micropore design iterations. The optically transparent dual-scale membranes enable complete observation of leukocyte egress across a variety of pore densities. A maximal density of ≈14 micropores per cell is discovered beyond which cell-substrate interactions are compromised giving rise to endothelial cell losses under flow. Addition of a subluminal extracellular matrix rescues cell adhesion, allowing for the creation of shear-primed endothelial barrier models on nearly 30% continuously porous substrates.
Collapse
Affiliation(s)
- Alec T Salminen
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14627, USA
| | - Jingkai Zhang
- Institute of Optics, University of Rochester, Rochester, NY, 14627, USA
| | - Gregory R Madejski
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14627, USA
| | - Tejas S Khire
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14627, USA
| | - Richard E Waugh
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14627, USA
| | - James L McGrath
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14627, USA
| | - Thomas R Gaborski
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14627, USA
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, 14623, USA
| |
Collapse
|
18
|
Rodler A, Schuster C, Berger E, Tscheließnig R, Jungbauer A. Freestanding ultrathin films for separation of small molecules in an aqueous environment. J Biotechnol 2018; 288:48-54. [DOI: 10.1016/j.jbiotec.2018.10.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Revised: 09/19/2018] [Accepted: 10/10/2018] [Indexed: 11/29/2022]
|
19
|
Chang JK, Emon MAB, Li CS, Yang Q, Chang HP, Yang Z, Wu CI, Saif MT, Rogers JA. Cytotoxicity and in Vitro Degradation Kinetics of Foundry-Compatible Semiconductor Nanomembranes and Electronic Microcomponents. ACS NANO 2018; 12:9721-9732. [PMID: 30160102 DOI: 10.1021/acsnano.8b04513] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Foundry-compatible materials and processing approaches serve as the foundations for advanced, active implantable microsystems that can dissolve in biofluids into biocompatible reaction products, with broad potential applications in biomedicine. The results reported here include in vitro studies of the dissolution kinetics and nanoscale bioresorption behaviors of device-grade thin films of Si, SiN x, SiO2, and W in the presence of dynamic cell cultures via atomic force microscopy and X-ray photoemission spectroscopy. In situ investigations of cell-extracellular mechanotransduction induced by cellular traction provide insights into the cytotoxicity of these same materials and of microcomponents formed with them using foundry-compatible processes, indicating potential cytotoxicity elicited by W at concentrations greater than 6 mM. The findings are of central relevance to the biocompatibility of modern Si-based electronics technologies as active, bioresorbable microsystems that interface with living tissues.
Collapse
Affiliation(s)
- Jan-Kai Chang
- Center for Bio-Integrated Electronics , Northwestern University , Evanston , Illinois 60208 , United States
| | - M A Bashar Emon
- Department of Mechanical Science and Engineering , University of Illinois at Urbana-Champaign , Urbana , Illinois 61801 , United States
| | - Chia-Shuo Li
- Graduate Institute of Photonics and Optoelectronics , National Taiwan University , Taipei 10617 , Taiwan
| | - Quansan Yang
- Center for Bio-Integrated Electronics , Northwestern University , Evanston , Illinois 60208 , United States
- Department of Mechanical Engineering , Northwestern University , Evanston , Illinois 60208 , United States
| | - Hui-Ping Chang
- Graduate Institute of Photonics and Optoelectronics , National Taiwan University , Taipei 10617 , Taiwan
- Frederick Seitz Materials Research Laboratory , University of Illinois at Urbana-Champaign , Urbana , Illinois 61801 , United States
| | - Zijian Yang
- Frederick Seitz Materials Research Laboratory , University of Illinois at Urbana-Champaign , Urbana , Illinois 61801 , United States
| | - Chih-I Wu
- Graduate Institute of Photonics and Optoelectronics , National Taiwan University , Taipei 10617 , Taiwan
| | - M Taher Saif
- Department of Mechanical Science and Engineering , University of Illinois at Urbana-Champaign , Urbana , Illinois 61801 , United States
| | - John A Rogers
- Center for Bio-Integrated Electronics , Northwestern University , Evanston , Illinois 60208 , United States
- Frederick Seitz Materials Research Laboratory , University of Illinois at Urbana-Champaign , Urbana , Illinois 61801 , United States
- Departments of Materials Science and Engineering, Biomedical Engineering, Neurological Surgery, Chemistry, Mechanical Engineering, Electrical Engineering and Computer Science, Simpson Querrey Institute for BioNanotechnology, McCormick School of Engineering, and Feinberg School of Medicine , Northwestern University , Evanston , Illinois 60208 , United States
| |
Collapse
|
20
|
Salminen A, Hill K, Henry Chung L, James McGrath L, Johnson DG. Protein Separation and Hemocompatibility of Nitride Membranes in Microfluidic Filtration Systems. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:5814-5817. [PMID: 30441657 PMCID: PMC6241304 DOI: 10.1109/embc.2018.8513538] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/29/2023]
Abstract
Improving the health outcomes for end-stage renal Disease (ESRD) patients on hemodialysis (HD) requires new technologies for wearable HD such as a highly efficient membrane that can achieve standard toxic clearance rates in small device footprints. Our group has developed nanoporous silicon nitride (NPN) membranes which are 100 to 1000 times thinner than conventional membranes and are orders-ofmagnitude more efficient for dialysis. Counter flow dialysis separation experiments were performed to measure urea clearance while microdialysis experiments were performed in a stirred beaker to measure the separation of cytochrome-c and albumin. Hemodialysis experiments testing for platelet activation as well as protein adhesion were performed. Devices for the counter flow experiments were constructed with polydimethylsiloxane (PDMS) and a NPN membrane chip. The counter flow devices reduced the urea by as much as 20%. The microdialysis experiments showed a diffusion of ~ 60% for the cytochrome-c while clearing ~ 20% of the Albumin. Initial hemocompatibility studies show that the NPN membrane surface is less prone to both protein adhesion and platelet activation when compared to positive control (glass).
Collapse
|
21
|
Chung HH, Mireles M, Kwarta BJ, Gaborski TR. Use of porous membranes in tissue barrier and co-culture models. LAB ON A CHIP 2018; 18:1671-1689. [PMID: 29845145 PMCID: PMC5997570 DOI: 10.1039/c7lc01248a] [Citation(s) in RCA: 76] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Porous membranes enable the partitioning of cellular microenvironments in vitro, while still allowing physical and biochemical crosstalk between cells, a feature that is often necessary for recapitulating physiological functions. This article provides an overview of the different membranes used in tissue barrier and cellular co-culture models with a focus on experimental design and control of these systems. Specifically, we discuss how the structural, mechanical, chemical, and even the optical and transport properties of different membranes bestow specific advantages and disadvantages through the context of physiological relevance. This review also explores how membrane pore properties affect perfusion and solute permeability by developing an analytical framework to guide the design and use of tissue barrier or co-culture models. Ultimately, this review offers insight into the important aspects one must consider when using porous membranes in tissue barrier and lab-on-a-chip applications.
Collapse
Affiliation(s)
- Henry H Chung
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, USA.
| | | | | | | |
Collapse
|
22
|
Abstract
Silicon nanomembranes are ultrathin, highly permeable, optically transparent and biocompatible substrates for the construction of barrier tissue models. Trans-epithelial/endothelial electrical resistance (TEER) is often used as a non-invasive, sensitive and quantitative technique to assess barrier function. The current study characterizes the electrical behavior of devices featuring silicon nanomembranes to facilitate their application in TEER studies. In conventional practice with commercial systems, raw resistance values are multiplied by the area of the membrane supporting cell growth to normalize TEER measurements. We demonstrate that under most circumstances, this multiplication does not 'normalize' TEER values as is assumed, and that the assumption is worse if applied to nanomembrane chips with a limited active area. To compare the TEER values from nanomembrane devices to those obtained from conventional polymer track-etched (TE) membranes, we develop finite element models (FEM) of the electrical behavior of the two membrane systems. Using FEM and parallel cell-culture experiments on both types of membranes, we successfully model the evolution of resistance values during the growth of endothelial monolayers. Further, by exploring the relationship between the models we develop a 'correction' function, which when applied to nanomembrane TEER, maps to experiments on conventional TE membranes. In summary, our work advances the the utility of silicon nanomembranes as substrates for barrier tissue models by developing an interpretation of TEER values compatible with conventional systems.
Collapse
|
23
|
Smith KJ, May M, Baltus R, McGrath JL. A predictive model of separations in dead-end filtration with ultrathin membranes. Sep Purif Technol 2017. [DOI: 10.1016/j.seppur.2017.07.032] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
24
|
de Mesy Bentley KL, Trombetta R, Nishitani K, Bello-Irizarry SN, Ninomiya M, Zhang L, Chung HL, McGrath JL, Daiss JL, Awad HA, Kates SL, Schwarz EM. Evidence of Staphylococcus Aureus Deformation, Proliferation, and Migration in Canaliculi of Live Cortical Bone in Murine Models of Osteomyelitis. J Bone Miner Res 2017; 32:985-990. [PMID: 27933662 PMCID: PMC5413415 DOI: 10.1002/jbmr.3055] [Citation(s) in RCA: 185] [Impact Index Per Article: 23.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Revised: 12/02/2016] [Accepted: 12/05/2016] [Indexed: 11/08/2022]
Abstract
Although Staphylococcus aureus osteomyelitis is considered to be incurable, the major bacterial reservoir in live cortical bone has remained unknown. In addition to biofilm bacteria on necrotic tissue and implants, studies have implicated intracellular infection of osteoblasts and osteocytes as a mechanism of chronic osteomyelitis. Thus, we performed the first systematic transmission electron microscopy (TEM) studies to formally define major reservoirs of S. aureus in chronically infected mouse (Balb/c J) long bone tissue. Although rare, evidence of colonized osteoblasts was found. In contrast, we readily observed S. aureus within canaliculi of live cortical bone, which existed as chains of individual cocci and submicron rod-shaped bacteria leading to biofilm formation in osteocyte lacunae. As these observations do not conform to the expectations of S. aureus as non-motile cocci 1.0 to 1.5 μm in diameter, we also performed immunoelectron microscopy (IEM) following in vivo BrdU labeling to assess the role of bacterial proliferation in canalicular invasion. The results suggest that the deformed bacteria: (1) enter canaliculi via asymmetric binary fission; and (2) migrate toward osteocyte lacunae via proliferation at the leading edge. Additional in vitro studies confirmed S. aureus migration through a 0.5-μm porous membrane. Collectively, these findings define a novel mechanism of bone infection, and provide possible new insight as to why S. aureus implant-related infections of bone tissue are so challenging to treat. © 2016 American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Karen L de Mesy Bentley
- University of Rochester School of Medicine and Dentistry, Rochester, NY, USA.,Department of Pathology & Laboratory Medicine, University of Rochester School of Medicine and Dentistry, Rochester, NY, USA.,Department of Orthopaedics, University of Rochester School of Medicine and Dentistry, Rochester, NY, USA
| | - Ryan Trombetta
- University of Rochester School of Medicine and Dentistry, Rochester, NY, USA.,Department of Biomedical Engineering, University of Rochester School of Medicine and Dentistry, Rochester, NY, USA
| | - Kohei Nishitani
- University of Rochester School of Medicine and Dentistry, Rochester, NY, USA
| | | | - Mark Ninomiya
- University of Rochester School of Medicine and Dentistry, Rochester, NY, USA
| | - Longze Zhang
- University of Rochester School of Medicine and Dentistry, Rochester, NY, USA
| | - Hung Li Chung
- Department of Biomedical Engineering, University of Rochester School of Medicine and Dentistry, Rochester, NY, USA
| | - James L McGrath
- Department of Biomedical Engineering, University of Rochester School of Medicine and Dentistry, Rochester, NY, USA
| | - John L Daiss
- University of Rochester School of Medicine and Dentistry, Rochester, NY, USA
| | - Hani A Awad
- University of Rochester School of Medicine and Dentistry, Rochester, NY, USA.,Department of Biomedical Engineering, University of Rochester School of Medicine and Dentistry, Rochester, NY, USA
| | - Stephen L Kates
- University of Rochester School of Medicine and Dentistry, Rochester, NY, USA.,Department of Orthopaedic Surgery, Virginia Commonwealth University Medical Center, Richmond, VA, USA
| | - Edward M Schwarz
- University of Rochester School of Medicine and Dentistry, Rochester, NY, USA.,Department of Pathology & Laboratory Medicine, University of Rochester School of Medicine and Dentistry, Rochester, NY, USA.,Department of Orthopaedics, University of Rochester School of Medicine and Dentistry, Rochester, NY, USA.,Department of Biomedical Engineering, University of Rochester School of Medicine and Dentistry, Rochester, NY, USA
| |
Collapse
|
25
|
Drieschner C, Minghetti M, Wu S, Renaud P, Schirmer K. Ultrathin Alumina Membranes as Scaffold for Epithelial Cell Culture from the Intestine of Rainbow Trout. ACS APPLIED MATERIALS & INTERFACES 2017; 9:9496-9505. [PMID: 28244327 DOI: 10.1021/acsami.7b00705] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Permeable membranes are indispensable for in vitro epithelial barrier models. However, currently available polymer-based membranes are low in porosity and relatively thick, resulting in a limited permeability and unrealistic culture conditions. In this study, we developed an ultrathin, nanoporous alumina membrane as novel cell culture interface for vertebrate cells, with focus on the rainbow trout (Onchorynchus mykiss) intestinal cell line RTgutGC. The new type of membrane is framed in a silicon chip for physical support and has a thickness of only 1 μm, with a porosity of 15% and homogeneous nanopores (Ø = 73 ± 21 nm). Permeability rates for small molecules, namely lucifer yellow, dextran 40, and bovine serum albumin, exceeded those of standard polyethylene terephthalate (PET) membranes by up to 27 fold. With the final goal to establish a representative model of the fish intestine for environmental toxicology, we engineered a simple culture setup, capable of testing the cellular response toward chemical exposure. Herein, cells were cultured in a monolayer on the alumina membranes and formed a polarized epithelium with apical expression of the tight junction protein ZO-1 within 14 days. Impedance spectroscopy, a noninvasive and real time electrical measurement, was used to determine cellular resistance during epithelial layer formation and chemical exposure to evaluate barrier functionality. Resistance values during epithelial development revealed different stages of epithelial maturity and were comparable with the in vivo situation. During chemical exposure, cellular resistance changed immediately when barrier tightness or cell viability was affected. Thus, our study demonstrates nanoporous alumina membranes as promising novel interface for alternative in vitro approaches, capable of allowing cell culture in a physiologically realistic manner and enabling high quality microscopy and sensitive measurement of cellular resistance.
Collapse
Affiliation(s)
- Carolin Drieschner
- Eawag, Swiss Federal Institute of Aquatic Science and Technology , 8600 Dübendorf, Switzerland
- Microsystems Laboratory 4, School of Architecture, École Polytechnique Fédérale de Lausanne , 1015 Lausanne, Switzerland
| | - Matteo Minghetti
- Eawag, Swiss Federal Institute of Aquatic Science and Technology , 8600 Dübendorf, Switzerland
- Department of Integrative Biology, Oklahoma State University , 74078 Oklahoma, United States
| | - Songmei Wu
- Microsystems Laboratory 4, School of Architecture, École Polytechnique Fédérale de Lausanne , 1015 Lausanne, Switzerland
- School of Science, Beijing Jiaotong University , 100044 Beijing, P. R China
| | - Philippe Renaud
- Microsystems Laboratory 4, School of Architecture, École Polytechnique Fédérale de Lausanne , 1015 Lausanne, Switzerland
| | - Kristin Schirmer
- Eawag, Swiss Federal Institute of Aquatic Science and Technology , 8600 Dübendorf, Switzerland
- Department of Civil and Environmental Engineering, School of Architecture, École Polytechnique Fédérale de Lausanne , 1015 Lausanne, Switzerland
- Institute of Biogeochemistry and Pollutant Dynamics, ETH-Zürich , 8093 Zürich, Switzerland
| |
Collapse
|
26
|
Carter RN, Casillo SM, Mazzocchi AR, DesOrmeaux JPS, Roussie JA, Gaborski TR. Ultrathin transparent membranes for cellular barrier and co-culture models. Biofabrication 2017; 9:015019. [PMID: 28140345 DOI: 10.1088/1758-5090/aa5ba7] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Typical in vitro barrier and co-culture models rely upon thick semi-permeable polymeric membranes that physically separate two compartments. Polymeric track-etched membranes, while permeable to small molecules, are far from physiological with respect to physical interactions with co-cultured cells and are not compatible with high-resolution imaging due to light scattering and autofluorescence. Here we report on an optically transparent ultrathin membrane with porosity exceeding 20%. We optimize deposition and annealing conditions to create a tensile and robust porous silicon dioxide membrane that is comparable in thickness to the vascular basement membrane (100-300 nm). We demonstrate that human umbilical vein endothelial cells (HUVECs) spread and proliferate on these membranes similarly to control substrates. Additionally, HUVECs are able to transfer cytoplasmic cargo to adipose-derived stem cells when they are co-cultured on opposite sides of the membrane, demonstrating its thickness supports physiologically relevant cellular interactions. Lastly, we confirm that these porous glass membranes are compatible with lift-off processes yielding membrane sheets with an active area of many square centimeters. We believe that these membranes will enable new in vitro barrier and co-culture models while offering dramatically improved visualization compared to conventional alternatives.
Collapse
Affiliation(s)
- Robert N Carter
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY 14623, United States of America. Department of Mechanical Engineering, Rochester Institute of Technology, Rochester, NY 14623, United States of America
| | | | | | | | | | | |
Collapse
|
27
|
Pensabene V, Costa L, Terekhov A, Gnecco JS, Wikswo J, Hofmeister W. Ultrathin Polymer Membranes with Patterned, Micrometric Pores for Organs-on-Chips. ACS APPLIED MATERIALS & INTERFACES 2016; 8:22629-36. [PMID: 27513606 PMCID: PMC5131702 DOI: 10.1021/acsami.6b05754] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The basal lamina or basement membrane (BM) is a key physiological system that participates in physicochemical signaling between tissue types. Its formation and function are essential in tissue maintenance, growth, angiogenesis, disease progression, and immunology. In vitro models of the BM (e.g., Boyden and transwell chambers) are common in cell biology and lab-on-a-chip devices where cells require apical and basolateral polarization. Extravasation, intravasation, membrane transport of chemokines, cytokines, chemotaxis of cells, and other key functions are routinely studied in these models. The goal of the present study was to integrate a semipermeable ultrathin polymer membrane with precisely positioned pores of 2 μm diameter in a microfluidic device with apical and basolateral chambers. We selected poly(l-lactic acid) (PLLA), a transparent biocompatible polymer, to prepare the semipermeable ultrathin membranes. The pores were generated by pattern transfer using a three-step method coupling femtosecond laser machining, polymer replication, and spin coating. Each step of the fabrication process was characterized by scanning electron microscopy to investigate reliability of the process and fidelity of pattern transfer. In order to evaluate the compatibility of the fabrication method with organs-on-a-chip technology, porous PLLA membranes were embedded in polydimethylsiloxane (PDMS) microfluidic devices and used to grow human umbilical vein endothelial cells (HUVECS) on top of the membrane with perfusion through the basolateral chamber. Viability of cells, optical transparency of membranes and strong adhesion of PLLA to PDMS were observed, thus confirming the suitability of the prepared membranes for use in organs-on-a-chip devices.
Collapse
Affiliation(s)
- Virginia Pensabene
- Department of Biomedical Engineering; Vanderbilt University, Nashville, TN 37235 USA
- School of Electronic and Electrical Engineering, University of Leeds, Leeds, LS2 9JT, UK
- School of Medicine, Leeds Institute of Biomedical and Clinical Sciences, University of Leeds, Leeds, LS9 7TF, UK
| | - Lino Costa
- Center for Laser Applications, University of Tennessee Space Institute, Tullahoma, TN 37388 USA
| | - Alexander Terekhov
- Center for Laser Applications, University of Tennessee Space Institute, Tullahoma, TN 37388 USA
| | - Juan S. Gnecco
- Department of Cellular and Molecular Pathology, Vanderbilt University, Nashville, TN 37235 USA
| | - John Wikswo
- Department of Biomedical Engineering; Vanderbilt University, Nashville, TN 37235 USA
- Vanderbilt Institute for Integrative Biosystems Research and Education; Vanderbilt University, Nashville, TN 37235 USA
- Department of Physics and Astronomy; Vanderbilt University, Nashville, TN 37235 USA
- Department of Molecular Physiology and Biophysics; Vanderbilt University, Nashville, TN 37235 USA
| | - William Hofmeister
- Center for Laser Applications, University of Tennessee Space Institute, Tullahoma, TN 37388 USA
- Vanderbilt Institute for Integrative Biosystems Research and Education; Vanderbilt University, Nashville, TN 37235 USA
| |
Collapse
|
28
|
Johnson DG, Pan S, Hayden A, McGrath JL. Nanoporous membrane robustness / stability in small form factor microfluidic filtration system. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2016:1955-1958. [PMID: 28268711 PMCID: PMC6390479 DOI: 10.1109/embc.2016.7591106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The development of wearable hemodialysis (HD) devices that replace center-based HD holds the promise to improve both outcomes and quality-of-life for patients with end-stage-renal disease (ERD). A prerequisite for these devices is the development of highly efficient membranes that can achieve high toxin clearance in small footprints. The ultrathin nanoporous membrane material developed by our group is orders of magnitude more permeable than conventional HD membranes. We report on our progress making a prototype wearable dialysis unit. First, we present data from benchtop studies confirming that clinical levels of urea clearance can be obtained in a small animal model with low blood flow rates. Second, we report on efforts to improve the mechanical robustness of high membrane area dialysis devices.
Collapse
Affiliation(s)
- Dean G. Johnson
- Biomedical Engineering Department, University of Rochester, NY 14623 USA (585-273-2156; )
| | - Sabrina Pan
- Biomedical Engineering Department, University of Rochester, NY 14623 USA
| | | | - James L. McGrath
- Biomedical Engineering Department, University of Rochester, NY 14623 USA
| |
Collapse
|
29
|
High-throughput platforms for the screening of new therapeutic targets for neurodegenerative diseases. Drug Discov Today 2016; 21:1355-1366. [PMID: 27178019 DOI: 10.1016/j.drudis.2016.05.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Revised: 04/01/2016] [Accepted: 05/04/2016] [Indexed: 12/13/2022]
Abstract
Despite the recent progress in the understanding of neurodegenerative disorders, a lack of solid fundamental knowledge on the etiology of many of the major neurodegenerative diseases has made it difficult to obtain effective therapies to treat these conditions. Scientists have been looking to carry out more-human-relevant studies, with strong statistical power, to overcome the limitations of preclinical animal models that have contributed to the failure of numerous therapeutics in clinical trials. Here, we identify currently existing platforms to mimic central nervous system tissues, healthy and diseased, mainly focusing on cell-based platforms and discussing their strengths and limitations in the context of the high-throughput screening of new therapeutic targets and drugs.
Collapse
|
30
|
Bhadra P, Sengupta S, Ratchagar NP, Achar B, Chadha A, Bhattacharya E. Selective transportation of charged ZnO nanoparticles and microorganism dialysis through silicon nanoporous membranes. J Memb Sci 2016. [DOI: 10.1016/j.memsci.2015.12.058] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
31
|
Ryu S, Yoo J, Jang Y, Han J, Yu SJ, Park J, Jung SY, Ahn KH, Im SG, Char K, Kim BS. Nanothin Coculture Membranes with Tunable Pore Architecture and Thermoresponsive Functionality for Transfer-Printable Stem Cell-Derived Cardiac Sheets. ACS NANO 2015; 9:10186-202. [PMID: 26361723 DOI: 10.1021/acsnano.5b03823] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Coculturing stem cells with the desired cell type is an effective method to promote the differentiation of stem cells. The features of the membrane used for coculturing are crucial to achieving the best outcome. Not only should the membrane act as a physical barrier that prevents the mixing of the cocultured cell populations, but it should also allow effective interactions between the cells. Unfortunately, conventional membranes used for coculture do not sufficiently meet these requirements. In addition, cell harvesting using proteolytic enzymes following coculture impairs cell viability and the extracellular matrix (ECM) produced by the cultured cells. To overcome these limitations, we developed nanothin and highly porous (NTHP) membranes, which are ∼20-fold thinner and ∼25-fold more porous than the conventional coculture membranes. The tunable pore size of NTHP membranes at the nanoscale level was found crucial for the formation of direct gap junctions-mediated contacts between the cocultured cells. Differentiation of the cocultured stem cells was dramatically enhanced with the pore size-customized NTHP membrane system compared to conventional coculture methods. This was likely due to effective physical contacts between the cocultured cells and the fast diffusion of bioactive molecules across the membrane. Also, the thermoresponsive functionality of the NTHP membranes enabled the efficient generation of homogeneous, ECM-preserved, highly viable, and transfer-printable sheets of cardiomyogenically differentiated cells. The coculture platform developed in this study would be effective for producing various types of therapeutic multilayered cell sheets that can be differentiated from stem cells.
Collapse
Affiliation(s)
| | | | | | | | - Seung Jung Yu
- Department of Chemical and Biomolecular Engineering & KI for Nano Century, Korea Advanced Institute of Science and Technology , Daejeon 305-701, Republic of Korea
| | | | | | | | - Sung Gap Im
- Department of Chemical and Biomolecular Engineering & KI for Nano Century, Korea Advanced Institute of Science and Technology , Daejeon 305-701, Republic of Korea
| | | | | |
Collapse
|
32
|
Unal B. Investigation of the quenched surfaces of visibly luminescent macro/nanoporous silicon under the exposure of typical neuron culture media. SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY 2015. [DOI: 10.3103/s1068375515040146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
33
|
Qi C, Striemer CC, Gaborski TR, McGrath JL, Fauchet PM. Influence of silicon dioxide capping layers on pore characteristics in nanocrystalline silicon membranes. NANOTECHNOLOGY 2015; 26:055706. [PMID: 25590751 DOI: 10.1088/0957-4484/26/5/055706] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Porous nanocrystalline silicon (pnc-Si) membranes are a new class of membrane material with promising applications in biological separations. Pores are formed in a silicon film sandwiched between nm thick silicon dioxide layers during rapid thermal annealing. Controlling pore size is critical in the size-dependent separation applications. In this work, we systematically studied the influence of the silicon dioxide capping layers on pnc-Si membranes. Even a single nm thick top oxide layer is enough to switch from agglomeration to pore formation after annealing. Both the pore size and porosity increase with the thickness of the top oxide, but quickly reach a plateau after 10 nm of oxide. The bottom oxide layer acts as a barrier layer to prevent the a-Si film from undergoing homo-epitaxial growth during annealing. Both the pore size and porosity decrease as the thickness of the bottom oxide layer increases to 100 nm. The decrease of the pore size and porosity is correlated with the increased roughness of the bottom oxide layer, which hinders nanocrystal nucleation and nanopore formation.
Collapse
Affiliation(s)
- Chengzhu Qi
- Materials Science Program, University of Rochester, Rochester, NY 14627, USA. Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN 37235, USA
| | | | | | | | | |
Collapse
|
34
|
Nehilla BJ, Nataraj N, Gaborski TR, McGrath JL. Endothelial vacuolization induced by highly permeable silicon membranes. Acta Biomater 2014; 10:4670-4677. [PMID: 25072618 DOI: 10.1016/j.actbio.2014.07.022] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2014] [Revised: 06/14/2014] [Accepted: 07/18/2014] [Indexed: 11/24/2022]
Abstract
Assays for initiating, controlling and studying endothelial cell behavior and blood vessel formation have applications in developmental biology, cancer and tissue engineering. In vitro vasculogenesis models typically combine complex three-dimensional gels of extracellular matrix proteins with other stimuli like growth factor supplements. Biomaterials with unique micro- and nanoscale features may provide simpler substrates to study endothelial cell morphogenesis. In this work, patterns of nanoporous, nanothin silicon membranes (porous nanocrystalline silicon, or pnc-Si) are fabricated to control the permeability of an endothelial cell culture substrate. Permeability on the basal surface of primary and immortalized endothelial cells causes vacuole formation and endothelial organization into capillary-like structures. This phenomenon is repeatable, robust and controlled entirely by patterns of free-standing, highly permeable pnc-Si membranes. Pnc-Si is a new biomaterial with precisely defined micro- and nanoscale features that can be used as a unique in vitro platform to study endothelial cell behavior and vasculogenesis.
Collapse
|
35
|
DesOrmeaux JPS, Winans JD, Wayson SE, Gaborski TR, Khire TS, Striemer CC, McGrath JL. Nanoporous silicon nitride membranes fabricated from porous nanocrystalline silicon templates. NANOSCALE 2014; 6:10798-10805. [PMID: 25105590 DOI: 10.1039/c4nr03070b] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The extraordinary permeability and manufacturability of ultrathin silicon-based membranes are enabling devices with improved performance and smaller sizes in such important areas as molecular filtration and sensing, cell culture, electroosmotic pumping, and hemodialysis. Because of the robust chemical and mechanical properties of silicon nitride (SiN), several laboratories have developed techniques for patterning nanopores in SiN using reactive ion etching (RIE) through a template structure. These methods however, have failed to produce pores small enough for ultrafiltration (<100 nm) in SiN and involve templates that are prone to microporous defects. Here we present a facile, wafer-scale method to produce nanoporous silicon nitride (NPN) membranes using porous nanocrystalline silicon (pnc-Si) as a self-assembling, defect free, RIE masking layer. By modifying the mask layer morphology and the RIE etch conditions, the pore sizes of NPN can be adjusted between 40 nm and 80 nm with porosities reaching 40%. The resulting NPN membranes exhibit higher burst pressures than pnc-Si membranes while having 5× greater permeability. NPN membranes also demonstrate the capacity for high resolution separations (<10 nm) seen previously with pnc-Si membranes. We further demonstrate that human endothelial cells can be grown on NPN membranes, verifying the biocompatibility of NPN and demonstrating the potential of this material for cell culture applications.
Collapse
|
36
|
Porous Membranes Promote Endothelial Differentiation of Adipose-Derived Stem Cells and Perivascular Interactions. Cell Mol Bioeng 2014. [DOI: 10.1007/s12195-014-0354-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
|
37
|
Qi C, Striemer CC, Gaborski TR, McGrath JL, Fauchet PM. Highly porous silicon membranes fabricated from silicon nitride/silicon stacks. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2014; 10:2946-2953. [PMID: 24623562 DOI: 10.1002/smll.201303447] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2013] [Revised: 02/25/2014] [Indexed: 06/03/2023]
Abstract
Nanopore formation in silicon films has previously been demonstrated using rapid thermal crystallization of ultrathin (15 nm) amorphous Si films sandwiched between nm-thick SiO2 layers. In this work, the silicon dioxide barrier layers are replaced with silicon nitride, resulting in nanoporous silicon films with unprecedented pore density and novel morphology. Four different thin film stack systems including silicon nitride/silicon/silicon nitride (NSN), silicon dioxide/silicon/silicon nitride (OSN), silicon nitride/silicon/silicon dioxide (NSO), and silicon dioxide/silicon/silicon dioxide (OSO) are tested under different annealing temperatures. Generally the pore size, pore density, and porosity positively correlate with the annealing temperature for all four systems. The NSN system yields substantially higher porosity and pore density than the OSO system, with the OSN and NSO stack characteristics fallings between these extremes. The higher porosity of the Si membrane in the NSN stack is primarily due to the pore formation enhancement in the Si film. It is hypothesized that this could result from the interfacial energy difference between the silicon/silicon nitride and silicon/silicon dioxide, which influences the Si crystallization process.
Collapse
Affiliation(s)
- Chengzhu Qi
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, 37235, United States; Materials Science Program, University of Rochester, Rochester, NY, 14627, United States
| | | | | | | | | |
Collapse
|
38
|
Chung HH, Chan CK, Khire TS, Marsh GA, Clark A, Waugh RE, McGrath JL. Highly permeable silicon membranes for shear free chemotaxis and rapid cell labeling. LAB ON A CHIP 2014; 14:2456-68. [PMID: 24850320 PMCID: PMC4540053 DOI: 10.1039/c4lc00326h] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Microfluidic systems are powerful tools for cell biology studies because they enable the precise addition and removal of solutes in small volumes. However, the fluid forces inherent in the use of microfluidics for cell cultures are sometimes undesirable. An important example is chemotaxis systems where fluid flow creates well-defined and steady chemotactic gradients but also pushes cells downstream. Here we demonstrate a chemotaxis system in which two chambers are separated by a molecularly thin (15 nm), transparent, and nanoporous silicon membrane. One chamber is a microfluidic channel that carries a flow-generated gradient while the other chamber is a shear-free environment for cell observation. The molecularly thin membranes provide effectively no resistance to molecular diffusion between the two chambers, making them ideal elements for creating flow-free chambers in microfluidic systems. Analytical and computational flow models that account for membrane and chamber geometry, predict shear reduction of more than five orders of magnitude. This prediction is confirmed by observing the pure diffusion of nanoparticles in the cell-hosting chamber despite high input flow (Q = 10 μL min(-1); vavg ~ 45 mm min(-1)) in the flow chamber only 15 nm away. Using total internal reflection fluorescence (TIRF) microscopy, we show that a flow-generated molecular gradient will pass through the membrane into the quiescent cell chamber. Finally we demonstrate that our device allows us to expose migrating neutrophils to a chemotactic gradient or fluorescent label without any influence from flow.
Collapse
Affiliation(s)
- Henry H Chung
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, USA.
| | | | | | | | | | | | | |
Collapse
|
39
|
Alba M, Romano E, Formentín P, Eravuchira PJ, Ferré-Borrull J, Pallarès J, Marsal LF. Selective dual-side functionalization of hollow SiO2 micropillar arrays for biotechnological applications. RSC Adv 2014. [DOI: 10.1039/c3ra48062c] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
|
40
|
Wang K, Liu G, Hoivik N, Johannessen E, Jakobsen H. Electrochemical engineering of hollow nanoarchitectures: pulse/step anodization (Si, Al, Ti) and their applications. Chem Soc Rev 2013; 43:1476-500. [PMID: 24292021 DOI: 10.1039/c3cs60150a] [Citation(s) in RCA: 100] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Hollow nanoarchitectured materials with straight channels play a crucial role in the fields of renewable energy, environment and biotechnology due to their one-dimensional morphology and extraordinary properties. The current challenge is the difficulty on tailoring hollow nanoarchitectures with well-controlled morphology at a relatively low cost. As a conventional technique, electrochemistry exhibits its unique advantage on machining nanostructures. In this review, we present the progress of electrochemistry as a valuable tool in construction of novel hollow nanoarchitectures through pulse/step anodization, such as surface pre-texturing, modulated, branched and multilayered pore architectures, and free-standing membranes. Basic principles for electrochemical engineering of mono- or multi-ordered nanostructures as well as free-standing membranes are extracted from specific examples (i.e. porous silicon, aluminum and titanium oxide). The potential of such nanoarchitectures are further demonstrated for the applications of photovoltaics, water splitting, organic degradation, nanostructure templates, biosensors and drug release. The electrochemical techniques provide a powerful approach to produce nanostructures with morphological complexity, which could have far-reaching implications in the design of future nanoscale systems.
Collapse
Affiliation(s)
- Kaiying Wang
- Department of Micro and Nano Systems Technology, Vestfold University College, Horten, 3184, Norway.
| | | | | | | | | |
Collapse
|
41
|
Abstract
Here we review the recent applications of ion transfer (IT) at the interface between two immiscible electrolyte solutions (ITIES) for electrochemical sensing and imaging. In particular, we focus on the development and recent applications of the nanopipet-supported ITIES and double-polymer-modified electrode, which enable the dynamic electrochemical measurements of IT at nanoscopic and macroscopic ITIES, respectively. High-quality IT voltammograms are obtainable using either technique to quantitatively assess the kinetics and dynamic mechanism of IT at the ITIES. Nanopipet-supported ITIES serves as an amperometric tip for scanning electrochemical microscopy to allow for unprecedentedly high-resolution electrochemical imaging. Voltammetric ion sensing at double-polymer-modified electrodes offers high sensitivity and unique multiple-ion selectivity. The promising future applications of these dynamic approaches for bioanalysis and electrochemical imaging are also discussed.
Collapse
|
42
|
Premnath P, Tan B, Venkatakrishnan K. Bioactive interlinked extracellular matrix-like silicon nano-network fabricated by femtosecond laser synthesis. Biores Open Access 2013; 1:231-8. [PMID: 23514982 PMCID: PMC3559205 DOI: 10.1089/biores.2012.0254] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Nanostructured silicon has proven to be a promising candidate in tissue engineering. However, recent research on fabrication of silicon scaffolds has been limited to expensive, complex, and time-consuming lithographic techniques that require the addition of caustic chemicals. Moreover, these techniques generate structures that do not truly mimic the extracellular matrix (ECM). Therefore, we introduce a novel, interlinked, silicon nano-network fabricated by MHz ultrafast laser synthesis. We demonstrate that ultrafast laser synthesis is simple, rapid, free of any chemical additions, and can be carried out under ambient conditions. Variation in laser parameters resulted in an alteration in the pore size and density of the silicon fibrous network. Microscopic analysis revealed a highly charged silicon network with elevated adhesion forces. In vitro bioactivity tests indicate the precipitation of bone-like apatite in just 3 days. Cell proliferation studies on the silicon nano-network present a 300% increase in comparison to its bulk counterpart. Scanning electron microscopy analysis shows healthy migration and attachment of cells on the silicon nano-network. This study points to a correlation between elevated cell proliferation and the ECM-like structure of the silicon nano-network. This ECM-like silicon nano-network suggests significant potential not only in tissue engineering and regeneration but also in other biomedical applications such as biosensor detection.
Collapse
Affiliation(s)
- Priyatha Premnath
- Department of Mechanical and Industrial Engineering, Ryerson University , Toronto, Canada
| | | | | |
Collapse
|
43
|
Shen M, Ishimatsu R, Kim J, Amemiya S. Quantitative imaging of ion transport through single nanopores by high-resolution scanning electrochemical microscopy. J Am Chem Soc 2012; 134:9856-9. [PMID: 22655578 PMCID: PMC3380141 DOI: 10.1021/ja3023785] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Here we report on the unprecedentedly high resolution imaging of ion transport through single nanopores by scanning electrochemical microscopy (SECM). The quantitative SECM image of single nanopores allows for the determination of their structural properties, including their density, shape, and size, which are essential for understanding the permeability of the entire nanoporous membrane. Nanoscale spatial resolution was achieved by scanning a 17 nm radius pipet tip at a distance as low as 1.3 nm from a highly porous nanocrystalline silicon membrane in order to obtain the peak current response controlled by the nanopore-mediated diffusional transport of tetrabutylammonium ions to the nanopipet-supported liquid-liquid interface. A 280 nm × 500 nm image resolved 13 nanopores, which corresponds to a high density of 93 nanopores/μm(2). A finite element simulation of the SECM image was performed to assess quantitatively the spatial resolution limited by the tip diameter in resolving two adjacent pores and to determine the actual size of a nanopore, which was approximated as an elliptical cylinder with a depth of 30 nm and major and minor axes of 53 and 41 nm, respectively. These structural parameters were consistent with those determined by transmission electron microscopy, thereby confirming the reliability of quantitative SECM imaging at the nanoscale level.
Collapse
Affiliation(s)
- Mei Shen
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260
| | | | - Jiyeon Kim
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260
| | - Shigeru Amemiya
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260
| |
Collapse
|
44
|
Kavalenka MN, Striemer CC, Fang DZ, Gaborski TR, McGrath JL, Fauchet PM. Ballistic and non-ballistic gas flow through ultrathin nanopores. NANOTECHNOLOGY 2012; 23:145706. [PMID: 22433182 DOI: 10.1088/0957-4484/23/14/145706] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We show that ultrathin porous nanocrystalline silicon membranes exhibit gas permeance that is several orders of magnitude higher than other membranes. Using these membranes, gas flow obeying Knudsen diffusion has been studied in pores with lengths and diameters in the tens of nanometers regime. The components of the flow due to ballistic transport and transport after reflection from the pore walls were separated and quantified as a function of pore diameter. These results were obtained in pores made in silicon. We demonstrate that changing the pore interior to carbon leads to flow enhancement resulting from a change in the nature of molecule-pore wall interactions. This result confirms previously published flow enhancement results obtained in carbon nanotubes.
Collapse
Affiliation(s)
- M N Kavalenka
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY 14627, USA
| | | | | | | | | | | |
Collapse
|
45
|
Immunocytochemical and structural comparative study of committed versus multipotent stem cells cultured with different biomaterials. Micron 2012; 47:1-9. [PMID: 22440134 DOI: 10.1016/j.micron.2012.02.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2011] [Revised: 02/24/2012] [Accepted: 02/28/2012] [Indexed: 11/20/2022]
Abstract
The aim of this work was the comparison of the behavior of committed (human osteoblast cells - hOB - from bone biopsies) versus multipotent (human dental pulp stem cells - hDPSC - from extracted teeth) cells, cultured on shot-peened titanium surfaces, since the kind of cell model considered has been shown to be relevant in techniques widely used in studies on composition/morphology of biomaterial surfaces. The titanium surface morphology, with different roughness, and the behavior of cells were analyzed by confocal microscope (CM), scanning electron microscope (SEM) and X-ray microanalysis. The best results, in terms of hOB adhesion/distribution, were highlighted by both CM and SEM in cultured plates having 20-μm-depth cavities. On the contrary, CM and SEM results highlighted the hDPSC growth regardless the different surface morphology, arranged in overlapped layers due to their high proliferation rate, showing their unfitness in biomaterial surface test. Nevertheless, hDPSC cultured inside 3D-matrices reproduced an osteocyte-like three-dimensional network, potentially useful in the repair of critical size bone defects. The behavior of the two cell models suggests a different use in biomaterial cell cultures: committed osteoblast cells could be appropriate in selecting the best surfaces to improve osseointegration, while multipotent cells could be suitable to obtain in vitro osteocyte-like network for regenerative medicine. The originality of the present work consists in studying for the first time two different cell models (committed versus multipotent) compared in parallel different biomaterial cultures, thus suggesting distinct targets for each cellular model.
Collapse
|
46
|
Current World Literature. Curr Opin Nephrol Hypertens 2011; 20:561-7. [DOI: 10.1097/mnh.0b013e32834a3de5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
47
|
Snyder JL, Clark A, Fang DZ, Gaborski TR, Striemer CC, Fauchet PM, McGrath JL. An experimental and theoretical analysis of molecular separations by diffusion through ultrathin nanoporous membranes. J Memb Sci 2011; 369:119-129. [PMID: 21297879 DOI: 10.1016/j.memsci.2010.11.056] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Diffusion based separations are essential for laboratory and clinical dialysis processes. New molecularly thin nanoporous membranes may improve the rate and quality of separations achievable by these processes. In this work we have performed protein and small molecule separations with 15 nm thick porous nanocrystalline silicon (pnc-Si) membranes and compared the results to 1- and 3- dimensional models of diffusion through ultrathin membranes. The models predict the amount of resistance contributed by the membrane by using pore characteristics obtained by direct inspection of pnc-Si membranes in transmission electron micrographs. The theoretical results indicate that molecularly thin membranes are expected to enable higher resolution separations at times before equilibrium compared to thicker membranes with the same pore diameters and porosities. We also explored the impact of experimental parameters such as porosity, pore distribution, diffusion time, and chamber size on the sieving characteristics. Experimental results are found to be in good agreement with the theory, and ultrathin membranes are shown to impart little overall resistance to the diffusion of molecules smaller than the physical pore size cutoff. The largest molecules tested experience more hindrance than expected from simulations indicating that factors not incorporated in the models, such as molecule shape, electrostatic repulsion, and adsorption to pore walls, are likely important.
Collapse
Affiliation(s)
- J L Snyder
- Department of Biochemistry and Biophysics, University of Rochester, 601 Elmwood Avenue, Box 712, Rochester, NY 14642
| | | | | | | | | | | | | |
Collapse
|
48
|
Ishimatsu R, Kim J, Jing P, Striemer CC, Fang DZ, Fauchet PM, McGrath JL, Amemiya S. Ion-selective permeability of an ultrathin nanoporous silicon membrane as probed by scanning electrochemical microscopy using micropipet-supported ITIES tips. Anal Chem 2011; 82:7127-34. [PMID: 20690617 DOI: 10.1021/ac1005052] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We report on the application of scanning electrochemical microscopy (SECM) to the measurement of the ion-selective permeability of porous nanocrystalline silicon membrane as a new type of nanoporous material with potential applications in analytical, biomedical, and biotechnology device development. The reliable measurement of high permeability in the molecularly thin nanoporous membrane to various ions is important for greater understanding of its structure-permeability relationship and also for its successful applications. In this work, this challenging measurement is enabled by introducing two novel features into amperometric SECM tips based on the micropipet-supported interface between two immiscible electrolyte solutions (ITIES) to reveal the important ion-transport properties of the ultrathin nanopore membrane. The tip of a conventional heat-pulled micropipet is milled using the focused ion beam (FIB) technique to be smoother, better aligned, and subsequently, approach closer to the membrane surface, which allows for more precise and accurate permeability measurement. The high membrane permeability to small monovalent ions is determined using FIB-milled micropipet tips to establish a theoretical formula for the membrane permeability that is controlled by free ion diffusion across water-filled nanopores. Moreover, the ITIES tips are rendered selective for larger polyions with biomedical importance, i.e., polyanionic pentasaccharide Arixtra and polycationic peptide protamine, to yield the membrane permeability that is lower than the corresponding diffusion-limited permeability. The hindered transport of the respective polyions is unequivocally ascribed to electrostatic and steric repulsions from the wall of the nanopores, i.e., the charge and size effects.
Collapse
Affiliation(s)
- Ryoichi Ishimatsu
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, USA
| | | | | | | | | | | | | | | |
Collapse
|
49
|
Fang DZ, Striemer CC, Gaborski TR, McGrath JL, Fauchet PM. Methods for controlling the pore properties of ultra-thin nanocrystalline silicon membranes. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2010; 22:454134. [PMID: 21339620 DOI: 10.1088/0953-8984/22/45/454134] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Porous nanocrystalline silicon (pnc-Si) membranes are a new class of solid-state ultra-thin membranes with promising applications ranging from biological separations to use as a platform for electron imaging and spectroscopy. Because the thickness of the membrane is only 15-30 nm, on the order of that of the molecules to be separated, mass transport through the membrane is greatly enhanced. For applications involving molecular separations, it is crucial that the membrane is highly permeable to some species while being nearly impermeable to others. An important approach to adjusting the permeability of a membrane is by changing the size and density of the pores. With pnc-Si, a rapid thermal treatment is used to induce nanopore formation in a thin film of nanocrystalline silicon, which is then released over a silicon scaffold using an anisotropic etchant. In this study, we examine the influence of thin film deposition and thermal treatment parameters on pore size and density.
Collapse
Affiliation(s)
- D Z Fang
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY 14627, USA
| | | | | | | | | |
Collapse
|
50
|
Fang DZ, Striemer CC, Gaborski TR, McGrath JL, Fauchet PM. Pore size control of ultrathin silicon membranes by rapid thermal carbonization. NANO LETTERS 2010; 10:3904-8. [PMID: 20839831 PMCID: PMC2967790 DOI: 10.1021/nl101602z] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Rapid thermal carbonization in a dilute acetylene (C(2)H(2)) atmosphere has been used to chemically modify and precisely tune the pore size of ultrathin porous nanocrystalline silicon (pnc-Si). The magnitude of size reduction was controlled by varying the process temperature and time. Under certain conditions, the carbon coating displayed atomic ordering indicative of graphene layer formation conformal to the pore walls. Initial experiments show that carbonized membranes follow theoretical predictions for hydraulic permeability and retain the precise separation capabilities of untreated membranes.
Collapse
Affiliation(s)
- David Z. Fang
- Department of Electrical and Computer Engineering, Box 270231, University of Rochester, Rochester, NY 14627
| | - Christopher C. Striemer
- Department of Electrical and Computer Engineering, Box 270231, University of Rochester, Rochester, NY 14627
- SiMPore, Inc. 150 Lucius Gordon Dr., West Henrietta, NY 14586
| | | | - James L. McGrath
- Department of Biomedical Engineering, Box 270168, University of Rochester, Rochester, NY 14627
| | - Philippe M. Fauchet
- Department of Electrical and Computer Engineering, Box 270231, University of Rochester, Rochester, NY 14627
- Corresponding author:
| |
Collapse
|