1
|
He X, Ren F, Wang Y, Zhang Z, Zhou J, Huang J, Cao S, Dong J, Wang R, Wu M, Liu J. Acoustofluidic-based microscopic examination for automated and point-of-care urinalysis. LAB ON A CHIP 2024. [PMID: 38904306 DOI: 10.1039/d4lc00408f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/22/2024]
Abstract
Urinalysis is a heavily used diagnostic test in clinical laboratories; however, it is chronically held back by urine sediment microscopic examination. Current instruments are bulky and expensive to be widely adopted, making microscopic examination a procedure that still relies on manual operations and requires large time and labor costs. To improve the efficacy and automation of urinalysis, this study develops an acoustofluidic-based microscopic examination system. The system utilizes the combination of acoustofluidic manipulation and a passive hydrodynamic mechanism, and thus achieves a high throughput (1000 μL min-1) and a high concentration factor (95.2 ± 2.1 fold) simultaneously, fulfilling the demands for urine examination. The concentrated urine sample is automatically dispensed into a hemocytometer chamber and the images are then analyzed using a machine learning algorithm. The whole process is completed within 3 minutes with detection accuracies of erythrocytes and leukocytes of 94.6 ± 3.5% and 95.1 ± 1.8%, respectively. The examination outcome of urine samples from 50 volunteers by this device shows a correlation coefficient of 0.96 compared to manual microscopic examination. Our system offers a promising tool for automated urine microscopic examination, thus it has potential to save a large amount of time and labor in clinical laboratories, as well as to promote point-of-care urine testing applications in and beyond hospitals.
Collapse
Affiliation(s)
- Xin He
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian, 116024, China.
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, Liaoning, 116024, China
| | - Feng Ren
- The Second Hospital of Dalian Medical University, Dalian 116027, China
| | - Yangyang Wang
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian, 116024, China.
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, Liaoning, 116024, China
| | - Zhiyuan Zhang
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian, 116024, China.
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, Liaoning, 116024, China
| | - Jiming Zhou
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian, 116024, China.
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, Liaoning, 116024, China
| | - Jian Huang
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian, 116024, China.
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, Liaoning, 116024, China
| | - Shuye Cao
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian, 116024, China.
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, Liaoning, 116024, China
| | - Jinying Dong
- The Second Hospital of Dalian Medical University, Dalian 116027, China
| | - Renxin Wang
- State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, Shanxi, 030051, China
| | - Mengxi Wu
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian, 116024, China.
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, Liaoning, 116024, China
| | - Junshan Liu
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian, 116024, China.
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, Liaoning, 116024, China
| |
Collapse
|
2
|
Tsai T, Vyas PD, Crowell LL, Tran M, Ward DW, Qin Y, Castro A, Adams TNG. Electrical signature of heterogeneous human mesenchymal stem cells. Electrophoresis 2024. [PMID: 38738344 DOI: 10.1002/elps.202300202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 03/15/2024] [Accepted: 03/27/2024] [Indexed: 05/14/2024]
Abstract
Human mesenchymal stem cells (hMSCs) have gained traction in transplantation therapy due to their immunomodulatory, paracrine, immune-evasive, and multipotent differentiation potential. The inherent heterogeneity of hMSCs poses a challenge for therapeutic treatments and necessitates the identification of robust biomarkers to ensure reproducibility in both in vivo and in vitro experiments. In this study, we utilized dielectrophoresis (DEP), a label-free electrokinetic phenomenon, to investigate the heterogeneity of hMSCs derived from bone marrow (BM) and adipose tissue (AD). The electrical properties of BM-hMSCs were compared to homogeneous mouse fibroblasts (NIH-3T3), human fibroblasts (WS1), and human embryonic kidney cells (HEK-293). The DEP profile of BM-hMSCs differed most from HEK-293 cells. We compared the DEP profiles of BM-hMSCs and AD-hMSCs and found that they have similar membrane capacitances, differing cytoplasm conductivity, and transient slopes. Inducing both populations to differentiate into adipocyte and osteoblast cells revealed that they behave differently in response to differentiation-inducing cytokines. Histology and reverse transcription-quantitative polymerase chain reaction (RT-qPCR) analyses of the differentiation-related genes revealed differences in heterogeneity between BM-hMSCs and AD-hMSCs. The differentiation profiles correlate well with the DEP profiles developed and indicate differences in the heterogeneity of BM-hMSCs and AD-hMSCs. Our results demonstrate that using DEP, membrane capacitance, cytoplasm conductivity, and transient slope can uniquely characterize the inherent heterogeneity of hMSCs to guide robust and reproducible stem cell transplantation therapies.
Collapse
Affiliation(s)
- Tunglin Tsai
- Department of Chemical and Biomolecular Engineering, University of California Irvine, Irvine, California, USA
- Sue and Bill Gross Stem Cell Research Center, University of California Irvine, Irvine, California, USA
| | - Prema D Vyas
- Department of Chemical and Biomolecular Engineering, University of California Irvine, Irvine, California, USA
| | - Lexi L Crowell
- Department of Chemical and Biomolecular Engineering, University of California Irvine, Irvine, California, USA
- Sue and Bill Gross Stem Cell Research Center, University of California Irvine, Irvine, California, USA
| | - Mary Tran
- Department of Chemical and Biomolecular Engineering, University of California Irvine, Irvine, California, USA
- Sue and Bill Gross Stem Cell Research Center, University of California Irvine, Irvine, California, USA
| | - Destiney W Ward
- Department of Chemical and Biomolecular Engineering, University of California Irvine, Irvine, California, USA
| | - Yufan Qin
- Department of Chemical and Biomolecular Engineering, University of California Irvine, Irvine, California, USA
| | - Angie Castro
- Department of Chemical and Biomolecular Engineering, University of California Irvine, Irvine, California, USA
| | - Tayloria N G Adams
- Department of Chemical and Biomolecular Engineering, University of California Irvine, Irvine, California, USA
- Sue and Bill Gross Stem Cell Research Center, University of California Irvine, Irvine, California, USA
- Department of Biomedical Engineering, University of California Irvine, Irvine, California, USA
| |
Collapse
|
3
|
Zhao K, Yao J, Wei Y, Kong D, Wang J. Numerical studies of manipulation and separation of microparticles in ODEP-based microfluidic chips. Electrophoresis 2024. [PMID: 38419136 DOI: 10.1002/elps.202300265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 01/29/2024] [Accepted: 02/01/2024] [Indexed: 03/02/2024]
Abstract
A novel optical-induced dielectrophoresis (ODEP) method employing a pressure-driven flow for the continuous separation of microparticles is presented in this study. By applying alternate current electric field on conductive indium tin oxide substrate and projecting the light geometry into the photoconductive layer, an inhomogeneous electric field is locally induced. The particles experience the dielectrophoretic force when passing through the lighting area, where the strongest electrical field gradient exists. By optimizing the structure of the lighting pattern, a stronger nonuniform electric field gradient is generated which predicts the separation of 1 and 3 µm polystyrene particles. Moreover, the effects of key parameters, including the light pattern geometry, applied voltage, and flow rate, were investigated in this study, leading to the successful sorting of 700 nm and 1 µm particles. To further examine the separation sensitivity and practicability of the proposed ODEP microfluidic method, the isolation of two different types of circulating tumor cells from T-cells and red blood cells are demonstrated, providing a novel method for the manipulation and separation of microparticles and nanoparticles.
Collapse
Affiliation(s)
- Kai Zhao
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, Dalian, P. R. China
- Department of Information Science and Technology, Dalian Maritime University, Dalian, P. R. China
| | - Junzhu Yao
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, Dalian, P. R. China
- Department of Information Science and Technology, Dalian Maritime University, Dalian, P. R. China
| | - Yunman Wei
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, Dalian, P. R. China
- Department of Information Science and Technology, Dalian Maritime University, Dalian, P. R. China
| | - Dejian Kong
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, Dalian, P. R. China
- Department of Information Science and Technology, Dalian Maritime University, Dalian, P. R. China
| | - Junsheng Wang
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, Dalian, P. R. China
- Department of Information Science and Technology, Dalian Maritime University, Dalian, P. R. China
| |
Collapse
|
4
|
de Los Santos-Ramirez JM, Boyas-Chavez PG, Cerrillos-Ordoñez A, Mata-Gomez M, Gallo-Villanueva RC, Perez-Gonzalez VH. Trends and challenges in microfluidic methods for protein manipulation-A review. Electrophoresis 2024; 45:69-100. [PMID: 37259641 DOI: 10.1002/elps.202300056] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 05/06/2023] [Accepted: 05/11/2023] [Indexed: 06/02/2023]
Abstract
Proteins are important molecules involved in an immensely large number of biological processes. Being capable of manipulating proteins is critical for developing reliable and affordable techniques to analyze and/or detect them. Such techniques would enable the production of therapeutic agents for the treatment of diseases or other biotechnological applications (e.g., bioreactors or biocatalysis). Microfluidic technology represents a potential solution to protein manipulation challenges because of the diverse phenomena that can be exploited to achieve micro- and nanoparticle manipulation. In this review, we discuss recent contributions made in the field of protein manipulation in microfluidic systems using different physicochemical principles and techniques, some of which are miniaturized versions of already established macro-scale techniques.
Collapse
Affiliation(s)
| | - Pablo G Boyas-Chavez
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Nuevo León, Mexico
| | | | - Marco Mata-Gomez
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Nuevo León, Mexico
| | | | | |
Collapse
|
5
|
Alkhaiyat AM, Badran M. Numerical Simulation of a Lab-on-Chip for Dielectrophoretic Separation of Circulating Tumor Cells. MICROMACHINES 2023; 14:1769. [PMID: 37763932 PMCID: PMC10534381 DOI: 10.3390/mi14091769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Revised: 08/20/2023] [Accepted: 08/26/2023] [Indexed: 09/29/2023]
Abstract
Circulating tumor cells (CTCs) are cancer cells detached from tumors that enter the bloodstream with the rest of the blood cells before settling on remote organs and growing. CTCs play a major role as a target for cancer diagnosis. This study aims to propose and simulate a lab-on-chip (LOC) design that separates CTCs from white blood cells (WBCs) and blood platelets (PLTs) using low-voltage dielectrophoretic separation with high efficiency. The proposed design include two stages a passive and an active one cascaded in a compact package. Numerical simulations are performed on the COMSOL Multiphysics® software package to optimize the geometric parameters of the LOC, such as the width and length of the microchannel and the number of electrodes and their arrangements. Moreover, the effects of adjusting the applied voltage values as well as buffer inlet velocity are investigated. The proposed LOC design uses four electrodes at ±2 V to achieve 100% separation efficiency for the three cell types in simulation. The 919 µm × 440 µm LOC has a channel width of 40 µm. The inlet velocities for the blood-carrying cells and buffer are 134 and 850 µm/s, respectively. The proposed LOC can be used for the early detection of CTCs, which can be beneficial in cancer diagnosis and early treatment. In addition, it can be used in cancer prognosis, treatment monitoring and personalizing medicine.
Collapse
Affiliation(s)
| | - Mohamed Badran
- Department of Mechanical Engineering, The American University in Cairo, New Cairo 11835, Egypt;
| |
Collapse
|
6
|
Derakhshan R, Bozorgzadeh A, Ramiar A. Numerical investigation of ternary particle separation in a microchannel with a wall-mounted obstacle using dielectrophoresis. J Chromatogr A 2023; 1702:464079. [PMID: 37263054 DOI: 10.1016/j.chroma.2023.464079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 05/09/2023] [Accepted: 05/16/2023] [Indexed: 06/03/2023]
Abstract
In recent years, microfluidic-based particle/cell manipulation techniques have catalyzed significant advances in several fields of science. As an efficient, precise, and label-free particle/cell manipulation technique, dielectrophoresis (DEP) has recently attracted widespread attention. This paper presents the design and investigation of a straight sheathless 3D microchannel with a wall-mounted trapezoidal obstacle for continuous-flow separation of three different populations of polystyrene (PS) particles (5, 10 and 20 µm) using DEP. An OpenFOAM code is developed to simulate and investigate the movement of particles in the microchannel. Then, the code is validated by performing various experimental tests using a microdevice previously fabricated in our lab. By comparing the numerical simulation results with the experimental tests, it can be claimed that the newly developed solver is highly accurate, and its results agree well with experimental tests. Next, the effect of various operational and geometrical parameters such as obstacle height, applied voltage, electrode pairs angle, and flow rate on the efficient focusing and separation of particles are numerically investigated. The results showed that efficient particle separation could only be achieved for obstacle heights of more than 350 µm. Furthermore, the appropriate voltage range for efficient particle separation is increased by decreasing the electrode angle as well as increasing the flow rate. Moreover, the results showed that by employing the appropriate channel design and operational conditions, at a maximum applied voltage of 10V, a sample flow rate of 2.5μL/min could be processed. The proposed design can be beneficial for integrating with lab-on-a-chip and clinical diagnosis applications due to advantages, such as simple design, no need for sheath flow, the simultaneous ternary separation of particles, and providing precise particle separation.
Collapse
Affiliation(s)
- Reza Derakhshan
- Mechanical Engineering Department, Microfluidics and MEMS lab, Babol Noshirvani University of Technology, Babol, Mazandaran, Iran.
| | - Ali Bozorgzadeh
- Mechanical Engineering Department, Microfluidics and MEMS lab, Babol Noshirvani University of Technology, Babol, Mazandaran, Iran.
| | - Abas Ramiar
- Mechanical Engineering Department, Microfluidics and MEMS lab, Babol Noshirvani University of Technology, Babol, Mazandaran, Iran.
| |
Collapse
|
7
|
Khouzestani A, Hojjat Y, Tavalaee M, Sadeghian H, Nasr-Esfahani MH. Enhancing the Accuracy of Measuring DEP Force Applied on Cells by Considering the Friction Effect. BIOSENSORS 2023; 13:bios13050540. [PMID: 37232901 DOI: 10.3390/bios13050540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 05/05/2023] [Accepted: 05/10/2023] [Indexed: 05/27/2023]
Abstract
The Dielectrophoresis (DEP) phenomenon has been widely used for cell separation in recent years. The experimental measurement of the DEP force is one of the concerns of scientists. This research presents a novel method for more accurately measuring the DEP force. The innovation of this method is considered the friction effect, which has been neglected in previous studies. For this purpose, first, the direction of the microchannel was aligned with the electrodes. As there was no DEP force in this direction, the release force of the cells caused by the fluid flow equaled the friction force between the cells and the substrate. Then, the microchannel was aligned perpendicular to the direction of the electrodes, and the release force was measured. The net DEP force was obtained by the difference between the release forces of these two alignments. In the experimental tests, the DEP force, when applied to the sperm and white blood cell (WBC), was measured. The WBC was used to validate the presented method. The experimental results showed that the forces applied by DEP to WBC and human sperm were 42 pN and 3 pN, respectively. On the other hand, with the conventional method, these figures were as high as 72 pN and 4 pN due to neglecting the friction force. The compression between the simulation results in COMSOL Multiphysics and the experiments determined the new approach to be valid and capable of use in any cell, such as sperm.
Collapse
Affiliation(s)
- Alireza Khouzestani
- Department of Mechanical Engineering, Tarbiat Modares University, Tehran 14115-175, Iran
| | - Yousef Hojjat
- Department of Mechanical Engineering, Tarbiat Modares University, Tehran 14115-175, Iran
| | - Marziyeh Tavalaee
- Department of Animal Biotechnology, Reproductive Biomedicine Research Center, Royan Institute for Biotechnology, ACECR, Isfahan 8165131378, Iran
| | - Hesam Sadeghian
- Department of Mechanical Engineering, Tarbiat Modares University, Tehran 14115-175, Iran
| | - Mohammad Hossein Nasr-Esfahani
- Department of Animal Biotechnology, Reproductive Biomedicine Research Center, Royan Institute for Biotechnology, ACECR, Isfahan 8165131378, Iran
- Isfahan Fertility and Infertility Center, Isfahan 8158858151, Iran
| |
Collapse
|
8
|
Keumarsi MM, Oskouei PF, Dezhkam R, Shamloo A, Vatandoust F, Amiri HA. Numerical study of a double-stair-shaped dielectrophoresis channel for continuous on-chip cell separation and lysis using finite element method. J Chromatogr A 2023; 1696:463960. [PMID: 37030128 DOI: 10.1016/j.chroma.2023.463960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 03/16/2023] [Accepted: 04/01/2023] [Indexed: 04/04/2023]
Abstract
Prognostication of numerous chronic diseases are in need of identifying circulating tumor cells (CTCs), afterwards, separating and reviving contaminated samples are required. Conventional methods of separating blood cells, namely cytometry or magnetically activated cell sorting, in many cases lose their functionality, or efficiency under different conditions. Hence microfluidic methods of separation have been implemented. Herein, an innovative integrated double stair-shaped microchannel is designed and optimized, capable of 'separation', and 'chemical lysis' simultaneously in which the lysis reagent concentration can be controlled to tune the lysis intensity. The method of insulator-based dielectrophoresis (iDEP), which is the main physics in this device, is utilized yielding maximum separation. Pivotal features of the applied voltage, the voltage difference, the angles and the number of stairs, and the width of the throat in the microchannel have been numerically explored in order to optimize the channel in terms of separation and the lysis buffer concentration. The overall state of optimum case for the voltage difference (ΔV) of 10 owns the following features: the number of stairs is 2, the angle of stairs is 110°, the width of throat is 140 μm, and the inlet voltages are 30 V and 40 V. Also, the overall state of optimum cases for delta possess the following features: the number of stairs is 2, the angle of stairs is 110°, the width of throat is 140 μm, and the inlet voltages are 30 V and 35 V.
Collapse
Affiliation(s)
| | - Pouria Feyzi Oskouei
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Rasool Dezhkam
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran; Stem Cell and Regenerative Medicine Center, Sharif University of Technology, Tehran, Iran
| | - Amir Shamloo
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran; Stem Cell and Regenerative Medicine Center, Sharif University of Technology, Tehran, Iran.
| | - Farzad Vatandoust
- School of Mechanical Engineering, Iran University of Science and Technology, Narmak, Tehran, Iran; Department of Biomechanics, School of Mechanical Engineering, Iran University of Science and Technology, Narmak, Tehran, Iran
| | - Hoseyn A Amiri
- School of Mechanical Engineering, Iran University of Science and Technology, Narmak, Tehran, Iran; Department of Biomechanics, School of Mechanical Engineering, Iran University of Science and Technology, Narmak, Tehran, Iran
| |
Collapse
|
9
|
Zhao K, Hu M, van Baalen C, Alvarez L, Isa L. Sorting of heterogeneous colloids by AC-dielectrophoretic forces in a microfluidic chip with asymmetric orifices. J Colloid Interface Sci 2023; 634:921-929. [PMID: 36571855 DOI: 10.1016/j.jcis.2022.12.108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 12/12/2022] [Accepted: 12/19/2022] [Indexed: 12/24/2022]
Abstract
HYPOTHESIS The synthesis of compositionally heterogeneous particles is central to the development of complex colloidal units for self-assembly and self-propulsion. Yet, as the complexity of particles grows, synthesis becomes more prone to "errors". We hypothesize that alternating-current dielectrophoretic forces can efficiently sort Janus particles, as a function of patch size and material, and colloidal dumbbells by size. EXPERIMENTS We prepared Janus particles with different patch size and material by physical vapor deposition and colloidal dumbbells via capillarity-assisted particle assembly. We then performed sorting experiments in a microfluidic chip comprising electrodes with asymmetric orifices, specifically exploiting the dielectric contrast between different portions of the particles or their size difference to steer them towards different outlets. FINDINGS We calculated that the DEP force for Janus particles may switch from positive to negative as a function of composition at a critical AC frequency, thus enabling sorting different particles crossing the electrodes' region. The predictions are confirmed by optical microscopy experiments. We also show that intact and "broken" dumbbells can be simply separated as they experience different DEP forces. The integration of multiple asymmetric orifices leads a larger zone with high field gradient to increase separation efficiency and makes it a promising tool to select precise particle populations, isolating fractions with narrowly distributed characteristics.
Collapse
Affiliation(s)
- Kai Zhao
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Department of Information Science and Technology, Dalian Maritime University, 116026 Dalian, China; Laboratory for Soft Materials and Interfaces, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland.
| | - Minghan Hu
- Laboratory for Soft Materials and Interfaces, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland
| | - Carolina van Baalen
- Laboratory for Soft Materials and Interfaces, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland
| | - Laura Alvarez
- Laboratory for Soft Materials and Interfaces, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland
| | - Lucio Isa
- Laboratory for Soft Materials and Interfaces, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland.
| |
Collapse
|
10
|
Recent advances in non-optical microfluidic platforms for bioparticle detection. Biosens Bioelectron 2023; 222:114944. [PMID: 36470061 DOI: 10.1016/j.bios.2022.114944] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 11/17/2022] [Accepted: 11/22/2022] [Indexed: 12/03/2022]
Abstract
The effective analysis of the basic structure and functional information of bioparticles are of great significance for the early diagnosis of diseases. The synergism between microfluidics and particle manipulation/detection technologies offers enhanced system integration capability and test accuracy for the detection of various bioparticles. Most microfluidic detection platforms are based on optical strategies such as fluorescence, absorbance, and image recognition. Although optical microfluidic platforms have proven their capabilities in the practical clinical detection of bioparticles, shortcomings such as expensive components and whole bulky devices have limited their practicality in the development of point-of-care testing (POCT) systems to be used in remote and underdeveloped areas. Therefore, there is an urgent need to develop cost-effective non-optical microfluidic platforms for bioparticle detection that can act as alternatives to optical counterparts. In this review, we first briefly summarise passive and active methods for bioparticle manipulation in microfluidics. Then, we survey the latest progress in non-optical microfluidic strategies based on electrical, magnetic, and acoustic techniques for bioparticle detection. Finally, a perspective is offered, clarifying challenges faced by current non-optical platforms in developing practical POCT devices and clinical applications.
Collapse
|
11
|
Tong Z, Shen C, Li Q, Yin H, Mao H. Combining sensors and actuators with electrowetting-on-dielectric (EWOD): advanced digital microfluidic systems for biomedical applications. Analyst 2023; 148:1399-1421. [PMID: 36752059 DOI: 10.1039/d2an01707e] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
The concept of digital microfluidics (DMF) enables highly flexible and precise droplet manipulation at a picoliter scale, making DMF a promising approach to realize integrated, miniaturized "lab-on-a-chip" (LOC) systems for research and clinical purposes. Owing to its simplicity and effectiveness, electrowetting-on-dielectric (EWOD) is one of the most commonly studied and applied effects to implement DMF. However, complex biomedical assays usually require more sophisticated sample handling and detection capabilities than basic EWOD manipulation. Alternatively, combined systems integrating EWOD actuators and other fluidic handling techniques are essential for bringing DMF into practical use. In this paper, we briefly review the main approaches for the integration/combination of EWOD with other microfluidic manipulation methods or additional external fields for specified biomedical applications. The form of integration ranges from independently operating sub-systems to fully coupled hybrid actuators. The corresponding biomedical applications of these works are also summarized to illustrate the significance of these innovative combination attempts.
Collapse
Affiliation(s)
- Zhaoduo Tong
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Chuanjie Shen
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Qiushi Li
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
| | - Hao Yin
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Hongju Mao
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
| |
Collapse
|
12
|
Gao T, Zhao K, Zhang J, Zhang K. DC-Dielectrophoretic Manipulation and Isolation of Microplastic Particle-Treated Microalgae Cells in Asymmetric-Orifice-Based Microfluidic Chip. MICROMACHINES 2023; 14:229. [PMID: 36677290 PMCID: PMC9865771 DOI: 10.3390/mi14010229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 01/10/2023] [Accepted: 01/13/2023] [Indexed: 06/17/2023]
Abstract
A novel direct-current dielectrophoretic (DC-DEP) method is proposed for the manipulation and isolation of microplastic particle (MP)-treated microalgae cells according to their dielectric properties in a microfluidic chip. The lateral migration and trajectory of the microalgae cells were investigated. To induce stronger DC-DEP effects, a non-homogeneous electric-field gradient was generated by applying the DC electric voltages through triple pairs of asymmetric orifices with three small orifices and one large orifice located on the opposite microchannel wall across the whole channel, leading to the enhanced magnitude of the non-uniform electric-field gradient and effective dielectrophoretic area. The effects of the applied voltage, the polystyrene (PS) adsorption coverage, and thickness on the DC-DEP behaviors and migration were numerically investigated, and it was found that the effect of the PS adsorption thickness of the Chlorella cells on the DC-DEP behaviors can be neglected, but the effect on their trajectory shifts cannot. In this way, the separation of 3 µm and 6 µm Chlorella coated with 100% PS particles and the isolation of the Chlorella cells from those coated with various coverages and thicknesses of PS particles was successfully achieved, providing a promising method for the isolation of microalgae cells and the removal of undesired cells from a target suspension.
Collapse
Affiliation(s)
- Tianbo Gao
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Department of Information Science and Technology, Dalian Maritime University, Dalian 116026, China
| | - Kai Zhao
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Department of Information Science and Technology, Dalian Maritime University, Dalian 116026, China
| | - Jiaqi Zhang
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
| | - Kaihuan Zhang
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
| |
Collapse
|
13
|
Zaman MA, Padhy P, Wu M, Ren W, Jensen MA, Davis RW, Hesselink L. Controlled Transport of Individual Microparticles Using Dielectrophoresis. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:101-110. [PMID: 36541659 PMCID: PMC10516752 DOI: 10.1021/acs.langmuir.2c02235] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
A dielectrophoretic device employing a planar array of microelectrodes is designed for controlled transport of individual microparticles. By exciting the electrodes in sequence, a moving dielectrophoretic force is created that can drag a particle across the electrodes in a straight line. The electrode shapes are designed to counter any lateral drift of the trapped particle during transport. This facilitates single particle transport by creating a narrow two-dimensional corridor for the moving dielectrophoretic force to operate on. The design and analysis processes are discussed in detail. Numerical simulations are performed to calculate the electromagnetic field distribution and the generated dielectrophoretic force near the electrodes. The Langevin equation is used for analyzing the trajectory of a microparticle under the influence of the external forces. The simulations show how the designed electrode geometry produces the necessary lateral confinement required for successful particle transport. Finally, experimental results are presented showing controlled bidirectional linear transport of single polystyrene beads of radius 10 and 5 μm for a distances 840 and 1100 μm, respectively. The capabilities of the proposed platform make it suitable for micro total analysis systems (μTAS) and lab-on-a-chip (LOC) applications.
Collapse
Affiliation(s)
- Mohammad Asif Zaman
- Department of Electrical Engineering, Stanford University, Stanford, California94305, United States
| | - Punnag Padhy
- Department of Electrical Engineering, Stanford University, Stanford, California94305, United States
| | - Mo Wu
- Department of Electrical Engineering, Stanford University, Stanford, California94305, United States
| | - Wei Ren
- Department of Electrical Engineering, Stanford University, Stanford, California94305, United States
| | - Michael Anthony Jensen
- Department of Biochemistry, Stanford University, Stanford, California94305, United States
| | - Ronald W Davis
- Department of Biochemistry, Stanford University, Stanford, California94305, United States
| | - Lambertus Hesselink
- Department of Electrical Engineering, Stanford University, Stanford, California94305, United States
| |
Collapse
|
14
|
Zhou J, Tao Y, Xue R, Ren Y. A Self-Powered Dielectrophoretic Microparticle Manipulation Platform Based on a Triboelectric Nanogenerator. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2207093. [PMID: 36222389 DOI: 10.1002/adma.202207093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 09/25/2022] [Indexed: 06/16/2023]
Abstract
Lab-on-a-chip systems aim to integrate laboratory operations on a miniaturized device with broad application prospects in the field of point-of-care testing. However, bulky peripheral power resources, such as high-voltage supplies, function generators, and amplifiers, hamper the commercialization of the system. In this work, a portable, self-powered microparticle manipulation platform based on triboelectrically driven dielectrophoresis (DEP) is reported. A rotary freestanding triboelectric nanogenerator (RF-TENG) and rectifier/filter circuit supply a high-voltage direct-current signal to form a non-uniform electric field within the microchannel, realizing controllable actuation of the microparticles through DEP. The operating mechanism of this platform and the control performance of the moving particles are systematically studied and analyzed. Randomly distributed particles converge in a row after passing through the serpentine channel and various particles are separated owing to the different DEP forces. Ultimately, the high-efficiency separation of live and dead yeast cells is achieved using this platform. RF-TENG as the power source for lab-on-a-chip exhibits better safety and portability than traditional high-voltage power sources. This study presents a promising solution for the commercialization of lab-on-a-chip.
Collapse
Affiliation(s)
- Jian Zhou
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, 150001, P. R. China
| | - Ye Tao
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, 150001, P. R. China
- School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, 02138, USA
| | - Rui Xue
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, 150001, P. R. China
| | - Yukun Ren
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, 150001, P. R. China
| |
Collapse
|
15
|
Giesler J, Weirauch L, Thöming J, Baune M, Pesch GR. High-throughput dielectrophoretic separator based on printed circuit boards. Electrophoresis 2023; 44:72-81. [PMID: 35968886 DOI: 10.1002/elps.202200131] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 07/22/2022] [Accepted: 08/10/2022] [Indexed: 02/01/2023]
Abstract
The separation of particles with respect to their intrinsic properties is an ongoing task in various fields such as biotechnology and recycling of electronic waste. Especially for small particles in the lower micrometer or nanometer range, separation techniques are a field of current research since many existing approaches lack either throughput or selectivity. Dielectrophoresis (DEP) is a technique that can address multiple particle properties, making it a potential candidate to solve challenging separation tasks. Currently, DEP is mostly used in microfluidic separators and thus limited in throughput. Additionally, DEP setups often require expensive components, such as electrode arrays fabricated in the clean room. Here, we present and characterize a separator based on two inexpensive custom-designed printed circuit boards (80 × 120 mm board size). The boards consist of interdigitated electrode arrays with 250 μ $250\ \umu$ m electrode width and spacing. We demonstrate the separation capabilities using polystyrene particles ranging from 500 nm to 6 μ $6\ \umu$ m in monodisperse experiments. Further, we demonstrate selective trapping at flow rates up to 240 ml/h in the presented device for a binary mixture. Our experiments demonstrate an affordable way to increase throughput in electrode-based DEP separators.
Collapse
Affiliation(s)
- Jasper Giesler
- Chemical Process Engineering, Faculty of Production Engineering, University of Bremen, Leobener Straße 6, 28359, Bremen, Germany
| | - Laura Weirauch
- Chemical Process Engineering, Faculty of Production Engineering, University of Bremen, Leobener Straße 6, 28359, Bremen, Germany
| | - Jorg Thöming
- Chemical Process Engineering, Faculty of Production Engineering, University of Bremen, Leobener Straße 6, 28359, Bremen, Germany
- MAPEX Center for Materials and Processes, University of Bremen, 28359, Bremen, Germany
- Center for Environmental Research and Sustainable Technology (UFT), University of Bremen, Leobener Straße 6, 28359, Bremen, Germany
| | - Michael Baune
- Chemical Process Engineering, Faculty of Production Engineering, University of Bremen, Leobener Straße 6, 28359, Bremen, Germany
- Center for Environmental Research and Sustainable Technology (UFT), University of Bremen, Leobener Straße 6, 28359, Bremen, Germany
| | - Georg R Pesch
- Chemical Process Engineering, Faculty of Production Engineering, University of Bremen, Leobener Straße 6, 28359, Bremen, Germany
- MAPEX Center for Materials and Processes, University of Bremen, 28359, Bremen, Germany
| |
Collapse
|
16
|
Design optimization and performance tuning of curved-DC-iDEP particle separation chips. Chem Eng Res Des 2023. [DOI: 10.1016/j.cherd.2022.11.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
17
|
Emmerich MEP, Sinnigen AS, Neubauer P, Birkholz M. Dielectrophoretic separation of blood cells. Biomed Microdevices 2022; 24:30. [PMID: 36006519 PMCID: PMC9411249 DOI: 10.1007/s10544-022-00623-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/07/2022] [Indexed: 11/02/2022]
Abstract
Microfluidic dielectrophoretic (DEP) devices enable the label-free separation and isolation of cells based on differences in their electrophysiological properties. The technique can serve as a tool in clinical diagnostics and medical research as it facilitates the analysis of patient-specific blood composition and the detection and isolation of pathogenic cells like circulating tumor cells or malaria-infected erythrocytes. This review compares different microfluidic DEP devices to separate platelets, erythrocytes and leukocytes including their cellular subclasses. An overview and experimental setups of different microfluidic DEP devices for the separation, trapping and isolation or purification of blood cells are detailed with respect to their technical design, electrode configuration, sample preparation, applied voltage and frequency and created DEP field based and related to the separation efficiency. The technique holds the promise that results can quickly be attained in clinical and ambulant settings. In particular, point-of-care-testing scenarios are favored by the extensive miniaturization, which would be enabled by microelectronical integration of DEP devices.
Collapse
Affiliation(s)
- Maria E. P. Emmerich
- Chair of Bioprocess Engineering, Institute of Biotechnology, TU Berlin, Ackerstrasse 76, ACK24, D-13355 Berlin, Germany
- IHP – Leibniz-Institut für innovative Mikroelektronik, Im Technologiepark 25, 15236 Frankfurt (Oder), Germany
| | - Anne-Sophie Sinnigen
- Chair of Bioprocess Engineering, Institute of Biotechnology, TU Berlin, Ackerstrasse 76, ACK24, D-13355 Berlin, Germany
| | - Peter Neubauer
- Chair of Bioprocess Engineering, Institute of Biotechnology, TU Berlin, Ackerstrasse 76, ACK24, D-13355 Berlin, Germany
| | - Mario Birkholz
- IHP – Leibniz-Institut für innovative Mikroelektronik, Im Technologiepark 25, 15236 Frankfurt (Oder), Germany
| |
Collapse
|
18
|
Bhat MP, Thendral V, Uthappa UT, Lee KH, Kigga M, Altalhi T, Kurkuri MD, Kant K. Recent Advances in Microfluidic Platform for Physical and Immunological Detection and Capture of Circulating Tumor Cells. BIOSENSORS 2022; 12:bios12040220. [PMID: 35448280 PMCID: PMC9025399 DOI: 10.3390/bios12040220] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 03/29/2022] [Accepted: 04/04/2022] [Indexed: 05/05/2023]
Abstract
CTCs (circulating tumor cells) are well-known for their use in clinical trials for tumor diagnosis. Capturing and isolating these CTCs from whole blood samples has enormous benefits in cancer diagnosis and treatment. In general, various approaches are being used to separate malignant cells, including immunomagnets, macroscale filters, centrifuges, dielectrophoresis, and immunological approaches. These procedures, on the other hand, are time-consuming and necessitate multiple high-level operational protocols. In addition, considering their low efficiency and throughput, the processes of capturing and isolating CTCs face tremendous challenges. Meanwhile, recent advances in microfluidic devices promise unprecedented advantages for capturing and isolating CTCs with greater efficiency, sensitivity, selectivity and accuracy. In this regard, this review article focuses primarily on the various fabrication methodologies involved in microfluidic devices and techniques specifically used to capture and isolate CTCs using various physical and biological methods as well as their conceptual ideas, advantages and disadvantages.
Collapse
Affiliation(s)
- Mahesh Padmalaya Bhat
- Centre for Research in Functional Materials (CRFM), Jain Global Campus, Jain University, Bengaluru 562112, Karnataka, India; (M.P.B.); (V.T.); (M.K.)
- Agricultural Automation Research Center, Chonnam National University, Gwangju 61186, Korea;
| | - Venkatachalam Thendral
- Centre for Research in Functional Materials (CRFM), Jain Global Campus, Jain University, Bengaluru 562112, Karnataka, India; (M.P.B.); (V.T.); (M.K.)
| | | | - Kyeong-Hwan Lee
- Agricultural Automation Research Center, Chonnam National University, Gwangju 61186, Korea;
- Department of Convergence Biosystems Engineering, Chonnam National University, Gwangju 61186, Korea
| | - Madhuprasad Kigga
- Centre for Research in Functional Materials (CRFM), Jain Global Campus, Jain University, Bengaluru 562112, Karnataka, India; (M.P.B.); (V.T.); (M.K.)
| | - Tariq Altalhi
- Department of Chemistry, Faculty of Science, Taif University, Taif 21944, Saudi Arabia;
| | - Mahaveer D. Kurkuri
- Centre for Research in Functional Materials (CRFM), Jain Global Campus, Jain University, Bengaluru 562112, Karnataka, India; (M.P.B.); (V.T.); (M.K.)
- Correspondence: (M.D.K.); (K.K.)
| | - Krishna Kant
- Departamento de Química Física, Campus Universitario, CINBIO Universidade de Vigo, 36310 Vigo, Spain
- Correspondence: (M.D.K.); (K.K.)
| |
Collapse
|
19
|
Ashaju A, Wood JA, Lammertink RGH. Electrocatalytic Reaction Induced Colloidal Accumulation: The Role of Dielectrophoresis. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:3040-3050. [PMID: 35230108 PMCID: PMC8928468 DOI: 10.1021/acs.langmuir.1c01938] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 02/15/2022] [Indexed: 06/14/2023]
Abstract
A surface-driven flow is generated during the electrocatalytic reaction of a platinum-gold bielectrode within hydrogen peroxide. This flow can be experimentally visualized and quantified using micrometer-sized particles that are transported by a flow field. Tracer particles, which possess an inherent surface charge, also interact with the induced electric field and exhibit a collective behavior at the surface of the electrodes where they accumulate. The underlying mechanism for the accumulation dynamics demonstrated by these catalytic pump systems has so far been lacking. In this work, the accumulation dynamics and kinetics were experimentally investigated. With use of numerical simulations, we demonstrate that the self-driven particle accumulation is controlled by a positive dielectrophoretic force, mediated by the reaction-induced electric and flow field. These results contribute to the fundamental knowledge on immobilized bimetallic systems.
Collapse
|
20
|
Williams SJ, Schneider JD, King BC, Green NG. Particle-Induced Electrostatic Repulsion within an Electric Curtain Operating below the Paschen Limit. MICROMACHINES 2022; 13:mi13020288. [PMID: 35208412 PMCID: PMC8878500 DOI: 10.3390/mi13020288] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 02/04/2022] [Accepted: 02/08/2022] [Indexed: 02/04/2023]
Abstract
The electric curtain is a platform developed to lift and transport charged particles in air. Its premise is the manipulation of charged particles; however, fewer investigations isolate dielectric forces that are observed at lower voltages (i.e., less than the Paschen limit). This work focuses on observations of simultaneous dielectrophoretic and electrostatic forces. The electric curtain was a printed circuit board with interdigitated electrodes (0.020 inch width and spacing) coated with a layer of polypropylene, where a standing wave or travelling wave AC signal was applied (50 Hz) to produce an electric field below the Paschen limit. Soda lime glass beads (180–212 µm) demonstrated oscillatory rolling via dielectrophoretic forces. In addition, several particles simultaneously experienced rapid projectile repulsion, a behavior consistent with electrostatic phenomena. This second result is discussed as a particle-induced local increase in the electric field, with simulations demonstrating that a particle in close proximity to the curtain’s surface produces a local field enhancement of over 2.5 times. The significance of this is that individual particles themselves can trigger electrostatic repulsion in an otherwise dielectric system. These results could be used for advanced applications where particles themselves provided triggered responses, perhaps for selective sorting of micrometer particles in air.
Collapse
Affiliation(s)
- Stuart J. Williams
- Department of Mechanical Engineering, University of Louisville, Louisville, KY 40292, USA; (J.D.S.); (B.C.K.)
- Correspondence: ; Tel.: +1-502-852-6340
| | - Joseph D. Schneider
- Department of Mechanical Engineering, University of Louisville, Louisville, KY 40292, USA; (J.D.S.); (B.C.K.)
| | - Benjamin C. King
- Department of Mechanical Engineering, University of Louisville, Louisville, KY 40292, USA; (J.D.S.); (B.C.K.)
| | - Nicolas G. Green
- Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK;
| |
Collapse
|
21
|
Zhu C, Maldonado J, Sengupta K. CMOS-Based Electrokinetic Microfluidics With Multi-Modal Cellular and Bio-Molecular Sensing for End-to-End Point-of-Care System. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:1250-1267. [PMID: 34914597 DOI: 10.1109/tbcas.2021.3136165] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The importance of point-of-care (POC) bio-molecular diagnostics capable of rapid analysis has become abundantly evident after the outbreak of the Covid-19 pandemic. While sensing interfaces for both protein and nucleic-acid based assays have been demonstrated with chip-scale systems, sample preparation in compact form factor has often been a major bottleneck in enabling end-to-end POC diagnostics. Miniaturization of an end-to-end system requires addressing the front-end sample processing, without which, the goal for low-cost POC diagnostics remain elusive. In this paper, we address bulk fluid processing with AC-osmotic based electrokinetic fluid flows that can be fully controlled, processed and automated by CMOS ICs, fabricated in TSMC 65 nm LP process. Here, we combine bulk fluid flow control with bio-molecular sensing, cell manipulation, cytometry, and separation-all of which are controlled with silicon chips for an all-in-one bio-sensing device. We show CMOS controlled pneumatic-free bulk fluid flow with fluid velocities reaching up to 160 μm/s within a microfluidic channel of 100 × 50 μm 2 of cross-sectional area. We incorporate electrode arrays to allow precise control and focused cell flows ( ±2 μm precision) for robust cytometry, and for subsequent separation. We also incorporate a 16-element impedance spectroscopy receiver array for cell and label-free protein sensing. The massive scalability of CMOS-driven microfluidics, manipulation, and sensing can lead to a new design space and a new class of miniaturized sensing technologies.
Collapse
|
22
|
Yang L, Yi W, Sun F, Xu M, Zeng Z, Bi X, Dong J, Xie Y, Li M. Application of Lab-on-Chip for Detection of Microbial Nucleic Acid in Food and Environment. Front Microbiol 2021; 12:765375. [PMID: 34803990 PMCID: PMC8600318 DOI: 10.3389/fmicb.2021.765375] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 10/08/2021] [Indexed: 12/26/2022] Open
Abstract
Various diseases caused by food-borne or environmental pathogenic microorganisms have been a persistent threat to public health and global economies. It is necessary to regularly detect microorganisms in food and environment to prevent infection of pathogenic microorganisms. However, most traditional detection methods are expensive, time-consuming, and unfeasible in practice in the absence of sophisticated instruments and trained operators. Point-of-care testing (POCT) can be used to detect microorganisms rapidly on site and greatly improve the efficiency of microbial detection. Lab-on-chip (LOC) is an emerging POCT technology with great potential by integrating most of the experimental steps carried out in the laboratory into a single monolithic device. This review will primarily focus on principles and techniques of LOC for detection of microbial nucleic acid in food and environment, including sample preparation, nucleic acid amplification and sample detection.
Collapse
Affiliation(s)
- Liu Yang
- Department of Hepatology Division 2, Beijing Ditan Hospital, Capital Medical University, Beijing, China
| | - Wei Yi
- Department of Gynecology and Obstetrics, Beijing Ditan Hospital, Capital Medical University, Beijing, China
| | - Fangfang Sun
- Department of Hepatology Division 2, Beijing Ditan Hospital, Capital Medical University, Beijing, China
| | - Mengjiao Xu
- Department of Hepatology Division 2, Beijing Ditan Hospital, Capital Medical University, Beijing, China
| | - Zhan Zeng
- Department of Hepatology Division 2, Peking University Ditan Teaching Hospital, Beijing, China
| | - Xiaoyue Bi
- Department of Hepatology Division 2, Beijing Ditan Hospital, Capital Medical University, Beijing, China
| | - Jianping Dong
- Department of Infectious Diseases, Haidian Hospital, Beijing Haidian Section of Peking University Third Hospital, Beijing, China
| | - Yao Xie
- Department of Hepatology Division 2, Beijing Ditan Hospital, Capital Medical University, Beijing, China.,Department of Hepatology Division 2, Peking University Ditan Teaching Hospital, Beijing, China
| | - Minghui Li
- Department of Hepatology Division 2, Beijing Ditan Hospital, Capital Medical University, Beijing, China.,Department of Hepatology Division 2, Peking University Ditan Teaching Hospital, Beijing, China
| |
Collapse
|
23
|
Sahin O, Kosar A, Yapici MK. Modeling the Dielectrophoretic Separation of Red Blood Cells (RBCs) from B-Lymphocytes (B-Cells) . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:1238-1241. [PMID: 34891511 DOI: 10.1109/embc46164.2021.9631013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The ability to characterize hematopoietic cells quickly and reliably is critical in precision medicine. Analysis of hematopoietic cells will lead to the diagnosis of various diseases, including infectious diseases and cancer. Microfluidic devices provide label-free, time-efficient, and quantitative analysis in this regard. A microfluidic system is provided in this work to separate Red blood cells (RBCs) from B-Lymphocytes (B-Cells). One of the ways for manipulating and separating micron-sized particles is dielectrophoresis (DEP). Dielectrophoretic manipulation of red blood cells (RBC) and B-Lymphocytes (B-Cells), with diameters of 2.8 μm and 3.29 μm, respectively, is studied. The simulation results of a microfluidic device with a sidewall electrode are shown. RBCs could be separated with 98 % efficiency from B-Cells at an applied voltage ±0.06 V with a frequency and flow rate of 10 kHz and 1.5 μL/s, respectively.
Collapse
|
24
|
Label-free enrichment of rare unconventional circulating neoplastic cells using a microfluidic dielectrophoretic sorting device. Commun Biol 2021; 4:1130. [PMID: 34561533 PMCID: PMC8463600 DOI: 10.1038/s42003-021-02651-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 09/08/2021] [Indexed: 02/08/2023] Open
Abstract
Cellular circulating biomarkers from the primary tumor such as circulating tumor cells (CTCs) and circulating hybrid cells (CHCs) have been described to harbor tumor-like phenotype and genotype. CHCs are present in higher numbers than CTCs supporting their translational potential. Methods for isolation of CHCs do not exist and are restricted to low-throughput, time consuming, and biased methodologies. We report the development of a label-free dielectrophoretic microfluidic platform facilitating enrichment of CHCs in a high-throughput and rapid fashion by depleting healthy peripheral blood mononuclear cells (PBMCs). We demonstrated up to 96.5% depletion of PBMCs resulting in 18.6-fold enrichment of cancer cells. In PBMCs from pancreatic adenocarcinoma patients, the platform enriched neoplastic cells identified by their KRAS mutant status using droplet digital PCR with one hour of processing. Enrichment was achieved in 75% of the clinical samples analyzed, establishing this approach as a promising way to non-invasively analyze tumor cells from patients.
Collapse
|
25
|
Maidin NNM, Buyong MR, Rahim RA, Mohamed MA. Dielectrophoresis applications in biomedical field and future perspectives in biomedical technology. Electrophoresis 2021; 42:2033-2059. [PMID: 34346062 DOI: 10.1002/elps.202100043] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 07/25/2021] [Accepted: 07/27/2021] [Indexed: 11/09/2022]
Abstract
Dielectrophoresis (DEP) is a technique to manipulate trajectories of polarisable particles in non-uniform electric fields by utilising unique dielectric properties. The manipulation of a cell using DEP has been demonstrated in various modes, thereby indicating potential applications in the biomedical field. In this review, recent DEP applications in the biomedical field are discussed. This review is intended to highlight research work that shows significant approach related to dielectrophoresis application in biomedical field reported between 2016 and 2020. Firstly, single-shell model and multiple-shell model of cells are introduced. Current device structures and recently introduced electrode patterns for DEP applications are discussed. Secondly, the biomedical uses of DEP in liquid biopsies, stem cell therapies, and diagnosis of infectious diseases due to bacteria and viruses are presented. Finally, the challenges in DEP research are discussed, and the reported solutions are explained. DEP's potential research directions are mentioned. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Nur Nasyifa Mohd Maidin
- Institute of Microengineering and Nanoelectronic (IMEN), Universiti Kebangsaan Malaysia (UKM), Bangi, Selangor, 43600, Malaysia
| | - Muhamad Ramdzan Buyong
- Institute of Microengineering and Nanoelectronic (IMEN), Universiti Kebangsaan Malaysia (UKM), Bangi, Selangor, 43600, Malaysia
| | - Ruslinda A Rahim
- Institute of Nano Electronic Engineering (INEE), Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, 01000, Malaysia.,National Nanotechnology Centre (NNC), Ministry of Science Technology and Innovation (MOSTI), Federal Government Administrative Centre, Putrajaya, 62662, Malaysia
| | - Mohd Ambri Mohamed
- Institute of Microengineering and Nanoelectronic (IMEN), Universiti Kebangsaan Malaysia (UKM), Bangi, Selangor, 43600, Malaysia
| |
Collapse
|
26
|
Ding L, Yang X, Gao Z, Effah CY, Zhang X, Wu Y, Qu L. A Holistic Review of the State-of-the-Art Microfluidics for Exosome Separation: An Overview of the Current Status, Existing Obstacles, and Future Outlook. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2007174. [PMID: 34047052 DOI: 10.1002/smll.202007174] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 02/25/2021] [Indexed: 06/12/2023]
Abstract
Exosomes, a class of small extracellular vesicles (30-150 nm), are secreted by almost all types of cells into virtually all body fluids. These small vesicles are attracting increasing research attention owing to their potential for disease diagnosis and therapy. However, their inherent heterogeneity and the complexity of bio-fluids pose significant challenges for their isolation. Even the "gold standard," differential centrifugation, suffers from poor yields and is time-consuming. In this context, recent developments in microfluidic technologies have provided an ideal system for exosome extraction and these devices exhibit some fascinating properties such as high speeds, good portability, and low sample volumes. In this review, the focus is on the state-of-the-art microfluidic technologies for exosome isolation and highlight potential directions for future research and development by analyzing the challenges faced by the current strategies.
Collapse
Affiliation(s)
- Lihua Ding
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Xiaonan Yang
- School of Information Engineering, Zhengzhou University, Zhengzhou, 450001, China
| | - Zibo Gao
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Clement Yaw Effah
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Xiaoju Zhang
- Department of Respiratory and Critical Care Medicine, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, 450001, China
| | - Yongjun Wu
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Lingbo Qu
- College of Chemistry, Zhengzhou University, Zhengzhou, 450001, China
- Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou University, Zhengzhou, 450001, China
| |
Collapse
|
27
|
Hyler AR, Hong D, Davalos RV, Swami NS, Schmelz EM. A novel ultralow conductivity electromanipulation buffer improves cell viability and enhances dielectrophoretic consistency. Electrophoresis 2021; 42:1366-1377. [PMID: 33687759 DOI: 10.1002/elps.202000324] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 01/23/2021] [Accepted: 02/27/2021] [Indexed: 12/21/2022]
Abstract
Cell separation has become a critical diagnostic, research, and treatment tool for personalized medicine. Despite significant advances in cell separation, most widely used applications require the use of multiple, expensive antibodies to known markers in order to identify subpopulations of cells for separation. Dielectrophoresis (DEP) provides a biophysical separation technique that can target cell subpopulations based on phenotype without labels and return native cells for downstream analysis. One challenge in employing any DEP device is the sample being separated must be transferred into an ultralow conductivity medium, which can be detrimental in retaining cells' native phenotypes for separation. Here, we measured properties of traditional DEP reagents and determined that after just 1-2 h of exposure and subsequent culture, cells' viability was significantly reduced below 50%. We developed and tested a novel buffer (Cyto Buffer) that achieved 6 weeks of stable shelf-life and demonstrated significantly improved viability and physiological properties. We then determined the impact of Cyto Buffer on cells' dielectric properties and morphology and found that cells retained properties more similar to that of their native media. Finally, we vetted Cyto Buffer's usability on a cell separation platform (Cyto R1) to determine combined efficacy for cell separations. Here, more than 80% of cells from different cell lines were recovered and were determined to be >70% viable following exposure to Cyto Buffer, flow stimulation, electromanipulation, and downstream collection and growth. The developed buffer demonstrated improved opportunities for electrical cell manipulation, enrichment, and recovery for next generation cell separations.
Collapse
Affiliation(s)
| | - Daly Hong
- CytoRecovery, Inc., Blacksburg, VA, USA
| | - Rafael V Davalos
- Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, USA
| | - Nathan S Swami
- Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, USA
| | - Eva M Schmelz
- Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, USA.,Human Nutrition, Foods and Exercise, Virginia Tech, Blacksburg, VA, USA
| |
Collapse
|
28
|
Deivasigamani R, Maidin NNM, Wee MFMR, Mohamed MA, Buyong MR. Dielectrophoresis Prototypic Polystyrene Particle Synchronization toward Alive Keratinocyte Cells for Rapid Chronic Wound Healing. SENSORS (BASEL, SWITZERLAND) 2021; 21:3007. [PMID: 33922993 PMCID: PMC8123363 DOI: 10.3390/s21093007] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 03/25/2021] [Accepted: 04/09/2021] [Indexed: 12/12/2022]
Abstract
Diabetes patients are at risk of having chronic wounds, which would take months to years to resolve naturally. Chronic wounds can be countered using the electrical stimulation technique (EST) by dielectrophoresis (DEP), which is label-free, highly sensitive, and selective for particle trajectory. In this study, we focus on the validation of polystyrene particles of 3.2 and 4.8 μm to predict the behavior of keratinocytes to estimate their crossover frequency (fXO) using the DEP force (FDEP) for particle manipulation. MyDEP is a piece of java-based stand-alone software used to consider the dielectric particle response to AC electric fields and analyzes the electrical properties of biological cells. The prototypic 3.2 and 4.8 μm polystyrene particles have fXO values from MyDEP of 425.02 and 275.37 kHz, respectively. Fibroblast cells were also subjected to numerical analysis because the interaction of keratinocytes and fibroblast cells is essential for wound healing. Consequently, the predicted fXO from the MyDEP plot for keratinocyte and fibroblast cells are 510.53 and 28.10 MHz, respectively. The finite element method (FEM) is utilized to compute the electric field intensity and particle trajectory based on DEP and drag forces. Moreover, the particle trajectories are quantified in a high and low conductive medium. To justify the simulation, further DEP experiments are carried out by applying a non-uniform electric field to a mixture of different sizes of polystyrene particles and keratinocyte cells, and these results are well agreed. The alive keratinocyte cells exhibit NDEP force in a highly conductive medium from 100 kHz to 25 MHz. 2D/3D motion analysis software (DIPP-MotionV) can also perform image analysis of keratinocyte cells and evaluate the average speed, acceleration, and trajectory position. The resultant NDEP force can align the keratinocyte cells in the wound site upon suitable applied frequency. Thus, MyDEP estimates the Clausius-Mossotti factors (CMF), FEM computes the cell trajectory, and the experimental results of prototypic polystyrene particles are well correlated and provide an optimistic response towards keratinocyte cells for rapid wound healing applications.
Collapse
Affiliation(s)
| | | | | | | | - Muhamad Ramdzan Buyong
- Institute of Microengineering and Nanoelectronics, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia; (R.D.); (N.N.M.M.); (M.F.M.R.W.); (M.A.M.)
| |
Collapse
|
29
|
Li Y, Wang Y, Wan K, Wu M, Guo L, Liu X, Wei G. On the design, functions, and biomedical applications of high-throughput dielectrophoretic micro-/nanoplatforms: a review. NANOSCALE 2021; 13:4330-4358. [PMID: 33620368 DOI: 10.1039/d0nr08892g] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
As an efficient, rapid and label-free micro-/nanoparticle separation technique, dielectrophoresis (DEP) has attracted widespread attention in recent years, especially in the field of biomedicine, which exhibits huge potential in biomedically relevant applications such as disease diagnosis, cancer cell screening, biosensing, and others. DEP technology has been greatly developed recently from the low-flux laboratory level to high-throughput practical applications. In this review, we summarize the recent progress of DEP technology in biomedical applications, including firstly the design of various types and materials of DEP electrode and flow channel, design of input signals, and other improved designs. Then, functional tailoring of DEP systems with endowed specific functions including separation, purification, capture, enrichment and connection of biosamples, as well as the integration of multifunctions, are demonstrated. After that, representative DEP biomedical application examples in aspects of disease detection, drug synthesis and screening, biosensing and cell positioning are presented. Finally, limitations of existing DEP platforms on biomedical application are discussed, in which emphasis is given to the impact of other electrodynamic effects such as electrophoresis (EP), electroosmosis (EO) and electrothermal (ET) effects on DEP efficiency. This article aims to provide new ideas for the design of novel DEP micro-/nanoplatforms with desirable high throughput toward application in the biomedical community.
Collapse
Affiliation(s)
- Yalin Li
- College of Chemistry and Chemical Engineering, Qingdao University, 266071 Qingdao, PR China.
| | - Yan Wang
- College of Chemistry and Chemical Engineering, Qingdao University, 266071 Qingdao, PR China.
| | - Keming Wan
- College of Chemistry and Chemical Engineering, Qingdao University, 266071 Qingdao, PR China.
| | - Mingxue Wu
- College of Chemistry and Chemical Engineering, Qingdao University, 266071 Qingdao, PR China.
| | - Lei Guo
- Research Center for High-Value Utilization of Waste Biomass, College of Life Science, College of Life Science, Qingdao University, 266071 Qingdao, PR China
| | - Xiaomin Liu
- College of Chemistry and Chemical Engineering, Qingdao University, 266071 Qingdao, PR China.
| | - Gang Wei
- College of Chemistry and Chemical Engineering, Qingdao University, 266071 Qingdao, PR China.
| |
Collapse
|
30
|
Xie Y, Rufo J, Zhong R, Rich J, Li P, Leong KW, Huang TJ. Microfluidic Isolation and Enrichment of Nanoparticles. ACS NANO 2020; 14:16220-16240. [PMID: 33252215 PMCID: PMC8164652 DOI: 10.1021/acsnano.0c06336] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Over the past decades, nanoparticles have increased in implementation to a variety of applications ranging from high-efficiency electronics to targeted drug delivery. Recently, microfluidic techniques have become an important tool to isolate and enrich populations of nanoparticles with uniform properties (e.g., size, shape, charge) due to their precision, versatility, and scalability. However, due to the large number of microfluidic techniques available, it can be challenging to identify the most suitable approach for isolating or enriching a nanoparticle of interest. In this review article, we survey microfluidic methods for nanoparticle isolation and enrichment based on their underlying mechanisms, including acoustofluidics, dielectrophoresis, filtration, deterministic lateral displacement, inertial microfluidics, optofluidics, electrophoresis, and affinity-based methods. We discuss the principles, applications, advantages, and limitations of each method. We also provide comparisons with bulk methods, perspectives for future developments and commercialization, and next-generation applications in chemistry, biology, and medicine.
Collapse
Affiliation(s)
- Yuliang Xie
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242, United States
| | - Joseph Rufo
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, North Carolina 27708, United States
| | - Ruoyu Zhong
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, North Carolina 27708, United States
| | - Joseph Rich
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26506, United States
| | - Kam W Leong
- Department of Biomedical Engineering, Columbia University, New York, New York 10032, United States
| | - Tony Jun Huang
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, North Carolina 27708, United States
| |
Collapse
|
31
|
Çağlayan Z, Demircan Yalçın Y, Külah H. A Prominent Cell Manipulation Technique in BioMEMS: Dielectrophoresis. MICROMACHINES 2020; 11:E990. [PMID: 33153069 PMCID: PMC7693018 DOI: 10.3390/mi11110990] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 10/22/2020] [Accepted: 10/28/2020] [Indexed: 12/17/2022]
Abstract
BioMEMS, the biological and biomedical applications of micro-electro-mechanical systems (MEMS), has attracted considerable attention in recent years and has found widespread applications in disease detection, advanced diagnosis, therapy, drug delivery, implantable devices, and tissue engineering. One of the most essential and leading goals of the BioMEMS and biosensor technologies is to develop point-of-care (POC) testing systems to perform rapid prognostic or diagnostic tests at a patient site with high accuracy. Manipulation of particles in the analyte of interest is a vital task for POC and biosensor platforms. Dielectrophoresis (DEP), the induced movement of particles in a non-uniform electrical field due to polarization effects, is an accurate, fast, low-cost, and marker-free manipulation technique. It has been indicated as a promising method to characterize, isolate, transport, and trap various particles. The aim of this review is to provide fundamental theory and principles of DEP technique, to explain its importance for the BioMEMS and biosensor fields with detailed references to readers, and to identify and exemplify the application areas in biosensors and POC devices. Finally, the challenges faced in DEP-based systems and the future prospects are discussed.
Collapse
Affiliation(s)
- Zeynep Çağlayan
- Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara 06800, Turkey; (Z.Ç.); (Y.D.Y.)
- METU MEMS Research and Application Center, Ankara 06800, Turkey
| | - Yağmur Demircan Yalçın
- Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara 06800, Turkey; (Z.Ç.); (Y.D.Y.)
- Mikro Biyosistemler Electronics Inc., Ankara 06530, Turkey
| | - Haluk Külah
- Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara 06800, Turkey; (Z.Ç.); (Y.D.Y.)
- METU MEMS Research and Application Center, Ankara 06800, Turkey
- Mikro Biyosistemler Electronics Inc., Ankara 06530, Turkey
| |
Collapse
|
32
|
B.I. MZA, Tirth V, Yousuff CM, Shukla NK, Islam S, Irshad K, Aarif KOM. Simulation Guided Microfluidic Design for Multitarget Separation Using Dielectrophoretic Principle. BIOCHIP JOURNAL 2020. [DOI: 10.1007/s13206-020-4406-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
33
|
Sengul E, Kara O, Yildizhan Y, Martinez-Duarte R, Elitas M. Single Cell Level Dielectrophoretic Responses & Dielectrophoretic Deformations of Monocytes to Quantify Population Heterogeneity. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2221-2226. [PMID: 33018449 DOI: 10.1109/embc44109.2020.9176521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Single-cell dielectrophoretic movement and dielectrophoretic deformation of monocyte cells were interrogated applying 20 Vpp, 50 kHz to 1 MHz signal in the 3D carbon electrode array. Heterogeneity of the monocyte population is shown in terms of the crossover frequencies, translational movement, and deformation index of the cells. The results presented that crossover range for monocytes was 100 kHz - 200 kHz, the translational movement of the cells was rapidly altered when the initial positions of the cells were in the negative dielectrophoretic region. Finally, the deformation index of the monocyte population varied from 0.5 to 1.5.
Collapse
|
34
|
Ma Z, Zhou Y, Cai F, Meng L, Zheng H, Ai Y. Ultrasonic microstreaming for complex-trajectory transport and rotation of single particles and cells. LAB ON A CHIP 2020; 20:2947-2953. [PMID: 32661536 DOI: 10.1039/d0lc00595a] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Precisely controllable transport and rotation of microparticles and cells has great potential to enable new capabilities for single-cell level analysis. In this work, we present versatile ultrasonic microstreaming based manipulation that enables active and precise control of transport and rotation of individual microscale particles and biological cells in a microfluidic device. Two different types of ultrasonic microstreaming flow patterns can be produced by oscillating embedded microstructures in circular and rectilinear vibration modes, which have been validated by both numerical simulation and experimental observation. We have further showcased the ability to transport individual microparticles along the outlines of complex alphabet letters, demonstrating the versatility and simplicity of single-particle level manipulation with bulk vibration.
Collapse
Affiliation(s)
- Zhichao Ma
- Pillar of Engineering Product Development, Singapore University of Technology and Design, Singapore 487372, Singapore.
| | | | | | | | | | | |
Collapse
|
35
|
|
36
|
Pesch GR, Du F. A review of dielectrophoretic separation and classification of non-biological particles. Electrophoresis 2020; 42:134-152. [PMID: 32667696 DOI: 10.1002/elps.202000137] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 07/08/2020] [Accepted: 07/08/2020] [Indexed: 02/06/2023]
Abstract
Dielectrophoresis (DEP) is a selective electrokinetic particle manipulation technology that is applied for almost 100 years and currently finds most applications in biomedical research using microfluidic devices operating at moderate to low throughput. This paper reviews DEP separators capable of high-throughput operation and research addressing separation and analysis of non-biological particle systems. Apart from discussing particle polarization mechanisms, this review summarizes the early applications of DEP for dielectric sorting of minerals and lists contemporary applications in solid/liquid, liquid/liquid, and solid/air separation, for example, DEP filtration or airborne fiber length classification; the review also summarizes developments in DEP fouling suppression, gives a brief overview of electrocoalescence and addresses current problems in high-throughput DEP separation. We aim to provide inspiration for DEP application schemes outside of the biomedical sector, for example, for the recovery of precious metal from scrap or for extraction of metal from low-grade ore.
Collapse
Affiliation(s)
- Georg R Pesch
- Faculty of Production Engineering, Chemical Process Engineering Group, University of Bremen, Bremen, Germany
| | - Fei Du
- Faculty of Production Engineering, Chemical Process Engineering Group, University of Bremen, Bremen, Germany
| |
Collapse
|
37
|
Using a Dielectrophoretic Microfluidic Biochip Enhanced Fertilization of Mouse Embryo in Vitro. MICROMACHINES 2020; 11:mi11080714. [PMID: 32717960 PMCID: PMC7464277 DOI: 10.3390/mi11080714] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Revised: 07/19/2020] [Accepted: 07/20/2020] [Indexed: 12/31/2022]
Abstract
Droplet microfluidics has appealed to many interests for its capability to epitomize cells in a microscale environment and it is also a forceful technique for high-throughput single-cell epitomization. A dielectrophoretic microfluidic system imitates the oviduct of mammals with a microchannel to achieve fertilization in vitro (IVF) of an imprinting control-region (ICR) mouse. We applied a microfluidic chip and a positive dielectrophoretic (p-DEP) force to capture and to screen the sperm for the purpose of manipulating the oocyte. The p-DEP responses of the oocyte and sperm were exhibited under applied bias conditions (waveform AC 10 Vpp, 1 MHz) for trapping 1 min. The insemination concentration of sperm nearby the oocyte was increased to enhance the probability of natural fertilization through the p-DEP force trapping. A simulation tool (CFDRC-ACE+) was used to simulate and to analyze the distribution of the electric field. The DEP microfluidic devices were fabricated using poly (dimethylsiloxane) (PDMS) and ITO (indium tin oxide)-glass with electrodes. We discuss the requirement of sperm in a DEP microfluidic chip at varied concentrations to enhance the future rate of fertilization in vitro for an oligozoospermia patient. The result indicates that the rate of fertility in our device is 17.2 ± 7.5% (n = 30) at about 3000 sperms, compatible with traditional droplet-based IVF, which is 14.2 ± 7.5% (n = 28).
Collapse
|
38
|
Elitas M, Sengul E. Quantifying Heterogeneity According to Deformation of the U937 Monocytes and U937-Differentiated Macrophages Using 3D Carbon Dielectrophoresis in Microfluidics. MICROMACHINES 2020; 11:mi11060576. [PMID: 32521676 PMCID: PMC7345647 DOI: 10.3390/mi11060576] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 06/04/2020] [Accepted: 06/08/2020] [Indexed: 12/14/2022]
Abstract
A variety of force fields have thus far been demonstrated to investigate electromechanical properties of cells in a microfluidic platform which, however, are mostly based on fluid shear stress and may potentially cause irreversible cell damage. This work presents dielectric movement and deformation measurements of U937 monocytes and U937-differentiated macrophages in a low conductive medium inside a 3D carbon electrode array. Here, monocytes exhibited a crossover frequency around 150 kHz and presented maximum deformation index at 400 kHz and minimum deformation index at 1 MHz frequencies at 20 Vpeak-peak. Although macrophages were differentiated from monocytes, their crossover frequency was lower than 50 kHz at 10 Vpeak-peak. The change of the deformation index for macrophages was more constant and lower than the monocyte cells. Both dielectric mobility and deformation spectra revealed significant differences between the dielectric responses of U937 monocytes and U937-differentiated macrophages, which share the same origin. This method can be used for label-free, specific, and sensitive single-cell characterization. Besides, damage of the cells by aggressive shear forces can, hence, be eliminated and cells can be used for downstream analysis. Our results showed that dielectric mobility and deformation have a great potential as an electromechanical biomarker to reliably characterize and distinguish differentiated cell populations from their progenitors.
Collapse
Affiliation(s)
- Meltem Elitas
- Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul 34956, Turkey;
- Sabanci University Nanotechnology Research and Application Center, Istanbul 34956, Turkey
- Correspondence: ; Tel.: +90-538-810-2930
| | - Esra Sengul
- Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul 34956, Turkey;
| |
Collapse
|
39
|
Precise capture and dynamic relocation of nanoparticulate biomolecules through dielectrophoretic enhancement by vertical nanogap architectures. Nat Commun 2020; 11:2804. [PMID: 32499540 PMCID: PMC7272609 DOI: 10.1038/s41467-020-16630-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Accepted: 05/15/2020] [Indexed: 01/04/2023] Open
Abstract
Toward the development of surface-sensitive analytical techniques for biosensors and diagnostic biochip assays, a local integration of low-concentration target materials into the sensing region of interest is essential to improve the sensitivity and reliability of the devices. As a result, the dynamic process of sorting and accurate positioning the nanoparticulate biomolecules within pre-defined micro/nanostructures is critical, however, it remains a huge hurdle for the realization of practical surface-sensitive biosensors and biochips. A scalable, massive, and non-destructive trapping methodology based on dielectrophoretic forces is highly demanded for assembling nanoparticles and biosensing tools. Herein, we propose a vertical nanogap architecture with an electrode-insulator-electrode stack structure, facilitating the generation of strong dielectrophoretic forces at low voltages, to precisely capture and spatiotemporally manipulate nanoparticles and molecular assemblies, including lipid vesicles and amyloid-beta protofibrils/oligomers. Our vertical nanogap platform, allowing low-voltage nanoparticle captures on optical metasurface designs, provides new opportunities for constructing advanced surface-sensitive optoelectronic sensors. Label-free trapping of nanoparticles via dielectophoretic forces is traditionally done with electrodes in a horizontal gap layout. Here, the authors present a vertical nanogap architecture, which allows for precise capture and spatiotemporal manipulation of nanoparticles and molecular assemblies.
Collapse
|
40
|
Rabbani MT, Sonker M, Ros A. Carbon nanotube dielectrophoresis: Theory and applications. Electrophoresis 2020; 41:1893-1914. [PMID: 32474942 DOI: 10.1002/elps.202000049] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 05/07/2020] [Accepted: 05/18/2020] [Indexed: 01/31/2023]
Abstract
Carbon nanotubes (CNTs) are one of the most extensively studied nanomaterials in the 21st century. Since their discovery in 1991, many studies have been reported advancing our knowledge in terms of their structure, properties, synthesis, and applications. CNTs exhibit unique electrothermal and conductive properties which, combined with their mechanical strength, have led to tremendous attention of CNTs as a nanoscale material in the past two decades. To introduce the various types of CNTs, we first provide basic information on their structure followed by some intriguing properties and a brief overview of synthesis methods. Although impressive advances have been demonstrated with CNTs, critical applications require purification, positioning, and separation to yield desired properties and functional elements. Here, we review a versatile technique to manipulate CNTs based on their dielectric properties, namely dielectrophoresis (DEP). A detailed discussion on the DEP aspects of CNTs including the theory and various technical microfluidic realizations is provided. Various advancements in DEP-based manipulations of single-walled and multiwalled CNTs are also discussed with special emphasis on applications involving separation, purification, sensing, and nanofabrication.
Collapse
Affiliation(s)
- Mohammad Towshif Rabbani
- School of Molecular Sciences, Arizona State University, Tempe, AZ, USA.,Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, AZ, USA
| | - Mukul Sonker
- School of Molecular Sciences, Arizona State University, Tempe, AZ, USA.,Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, AZ, USA
| | - Alexandra Ros
- School of Molecular Sciences, Arizona State University, Tempe, AZ, USA.,Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, AZ, USA
| |
Collapse
|
41
|
Alnaimat F, Mathew B, Hilal-Alnaqbi A. Modeling a Dielectrophoretic Microfluidic Device with Vertical Interdigitated Transducer Electrodes for Separation of Microparticles Based on Size. MICROMACHINES 2020; 11:mi11060563. [PMID: 32486442 PMCID: PMC7345043 DOI: 10.3390/mi11060563] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 05/28/2020] [Accepted: 05/28/2020] [Indexed: 01/09/2023]
Abstract
This article conceptualizes and mathematically models a dielectrophoretic microfluidic device with two sets of interdigitated transducer vertical electrodes for separation of a binary heterogeneous mixture of particles based on size; each set of electrodes is located on the sidewalls and independently controllable. To achieve separation in the proposed microfluidic device, the small microparticles are subjected to positive dielectrophoresis and the big microparticles do not experience dielectrophoresis. The mathematical model consists of equations describing the motion of each microparticle, fluid flow profile, and electric voltage and field profiles, and they are solved numerically. The equations of motion take into account the influence of phenomena, such as inertia, drag, dielectrophoresis, gravity, and buoyancy. The model is used for a parametric study to understand the influence of parameters on the performance of the microfluidic device. The parameters studied include applied electric voltages, electrode dimensions, volumetric flow rate, and number of electrodes. The separation efficiency of the big and small microparticles is found to be independent of and dependent on all parameters, respectively. On the other hand, the separation purity of the big and small microparticles is found to be dependent on and independent of all parameters, respectively. The mathematical model is useful in designing the proposed microfluidic device with the desired level of separation efficiency and separation purity.
Collapse
Affiliation(s)
- Fadi Alnaimat
- Mechanical Engineering Department, United Arab Emirates University, Al Ain P. O. Box 15551, UAE; (F.A.); (B.M.)
| | - Bobby Mathew
- Mechanical Engineering Department, United Arab Emirates University, Al Ain P. O. Box 15551, UAE; (F.A.); (B.M.)
| | - Ali Hilal-Alnaqbi
- Abu Dhabi Polytechnic, MBZ campus, Abu Dhabi P. O. Box. 111499, UAE
- Correspondence: ; Tel.: +971-2-695-1070
| |
Collapse
|
42
|
Adams TNG, Jiang AYL, Mendoza NS, Ro CC, Lee DH, Lee AP, Flanagan LA. Label-free enrichment of fate-biased human neural stem and progenitor cells. Biosens Bioelectron 2020; 152:111982. [PMID: 32056730 PMCID: PMC8860404 DOI: 10.1016/j.bios.2019.111982] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Revised: 11/21/2019] [Accepted: 12/20/2019] [Indexed: 12/12/2022]
Abstract
Human neural stem and progenitor cells (hNSPCs) have therapeutic potential to treat neural diseases and injuries since they provide neuroprotection and differentiate into astrocytes, neurons, and oligodendrocytes. However, cultures of hNSPCs are heterogeneous, containing cells linked to distinct differentiated cell fates. HNSPCs that differentiate into astrocytes are of interest for specific neurological diseases, creating a need for approaches that can detect and isolate these cells. Astrocyte-biased hNSPCs differ from other cell types in electrophysiological properties, namely membrane capacitance, and we hypothesized that this could be used to enrich these cells using dielectrophoresis (DEP). We implemented a two-step DEP sorting scheme, consisting of analysis to define the optimal sorting frequency followed by separation of cells at that frequency, to test whether astrocyte-biased cells could be separated from the other cell types present in hNSPC cultures. We developed a novel device that increased sorting reproducibility and provided both enriched and depleted cell populations in a single sort. Astrocyte-biased cells were successfully enriched from hNSPC cultures by DEP sorting, making this the first study to use electrophysiological properties for label-free enrichment of human astrocyte-biased cells. Enriched astrocyte-biased human cells enable future experiments to determine the specific properties of these important cells and test their therapeutic efficacy in animal models of neurological diseases.
Collapse
Affiliation(s)
- Tayloria N G Adams
- Department of Chemical and Biomolecular Engineering, University of California, Irvine, Irvine, CA, 92697-2580, USA; Department of Neurology, University of California, Irvine, Irvine, CA, 92697-6750, USA; Sue & Bill Gross Stem Cell Research Center, University of California, Irvine, CA, 92697-1705, USA.
| | - Alan Y L Jiang
- Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, 92697-2627, USA; Department of Neurology, University of California, Irvine, Irvine, CA, 92697-6750, USA; Sue & Bill Gross Stem Cell Research Center, University of California, Irvine, CA, 92697-1705, USA
| | - Nicolo S Mendoza
- Department of Neurology, University of California, Irvine, Irvine, CA, 92697-6750, USA; Sue & Bill Gross Stem Cell Research Center, University of California, Irvine, CA, 92697-1705, USA
| | - Clarissa C Ro
- Department of Neurology, University of California, Irvine, Irvine, CA, 92697-6750, USA; Sue & Bill Gross Stem Cell Research Center, University of California, Irvine, CA, 92697-1705, USA
| | - Do-Hyun Lee
- Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, 92697-2627, USA
| | - Abraham P Lee
- Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, 92697-2627, USA
| | - Lisa A Flanagan
- Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, 92697-2627, USA; Department of Neurology, University of California, Irvine, Irvine, CA, 92697-6750, USA; Sue & Bill Gross Stem Cell Research Center, University of California, Irvine, CA, 92697-1705, USA; Department of Anatomy & Neurobiology, University of California, Irvine, Irvine, CA, 92697-4291, USA.
| |
Collapse
|
43
|
Gudagunti FD, Velmanickam L, Nawarathna D, Lima IT. Nucleotide Identification in DNA Using Dielectrophoresis Spectroscopy. MICROMACHINES 2019; 11:mi11010039. [PMID: 31905617 PMCID: PMC7019800 DOI: 10.3390/mi11010039] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Revised: 12/23/2019] [Accepted: 12/26/2019] [Indexed: 11/27/2022]
Abstract
We show that negative dielectrophoresis (DEP) spectroscopy is an effective transduction mechanism of a biosensor for the detection of single nucleotide polymorphism (SNP) in a short DNA strand. We observed a frequency dependence of the negative DEP force applied by interdigitated electrodes to polystyrene microspheres (PM) with respect to changes in both the last and the second-to-last nucleotides of a single-strand DNA bound to the PM. The drift velocity of PM functionalized to single-strand DNA, which is proportional to the DEP force, was measured at the frequency range from 0.5 MHz to 2 MHz. The drift velocity was calculated using a custom-made automated software using real time image processing technique. This technology for SNP genotyping has the potential to be used in the diagnosis and the identification of genetic variants associated with diseases.
Collapse
|
44
|
Wu X, Bai Z, Wang L, Cui G, Yang M, Yang Q, Ma B, Song Q, Tian D, Ceyssens F, Puers R, Kraft M, Zhao W, Wen L. Magnetic Cell Centrifuge Platform Performance Study with Different Microsieve Pore Geometries. SENSORS (BASEL, SWITZERLAND) 2019; 20:E48. [PMID: 31861791 PMCID: PMC6983067 DOI: 10.3390/s20010048] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 12/04/2019] [Accepted: 12/17/2019] [Indexed: 12/21/2022]
Abstract
The detection and analysis of circulating tumor cells (CTCs) plays a crucial role in clinical practice. However, the heterogeneity and rarity of CTCs make their capture and separation from peripheral blood very difficult while maintaining their structural integrity and viability. We previously demonstrated the effectiveness of the Magnetic Cell Centrifuge Platform (MCCP), which combined the magnetic-labeling cell separation mechanism with the size-based method. In this paper, a comparison of the effectiveness of different microsieve pore geometries toward MCCP is demonstrated to improve the yield of the target cell capture. Firstly, models of a trapped cell with rectangular and circular pore geometries are presented to compare the contact force using finite element numerical simulations. The device performance is then evaluated with both constant pressure and constant flow rate experimental conditions. In addition, the efficient isolation of magnetically labeled Hela cells with red fluorescent proteins (target cells) from Hela cells with green fluorescent protein (background cells) is validated. The experimental results show that the circular sieves yield 97% purity of the target cells from the sample with a throughput of up to 2 μL/s and 66-fold sample enrichment. This finding will pave the way for the design of a higher efficient MCCP systems.
Collapse
Affiliation(s)
- Xinyu Wu
- School of Microelectronics, Beihang University, Beijing 100191, China; (X.W.)
- Beihang-Goertek Joint Microelectronics Institute, Qingdao Research Institute, Beihang University, Qingdao 266104, China
| | - Zhongyang Bai
- School of Microelectronics, Beihang University, Beijing 100191, China; (X.W.)
- Beihang-Goertek Joint Microelectronics Institute, Qingdao Research Institute, Beihang University, Qingdao 266104, China
| | - Lin Wang
- Beihang-Goertek Joint Microelectronics Institute, Qingdao Research Institute, Beihang University, Qingdao 266104, China
| | - Guangchao Cui
- School of Microelectronics, Beihang University, Beijing 100191, China; (X.W.)
- Beihang-Goertek Joint Microelectronics Institute, Qingdao Research Institute, Beihang University, Qingdao 266104, China
| | - Mengzheng Yang
- School of Microelectronics, Beihang University, Beijing 100191, China; (X.W.)
- Beihang-Goertek Joint Microelectronics Institute, Qingdao Research Institute, Beihang University, Qingdao 266104, China
| | - Qing Yang
- School of Microelectronics, Beihang University, Beijing 100191, China; (X.W.)
- Beihang-Goertek Joint Microelectronics Institute, Qingdao Research Institute, Beihang University, Qingdao 266104, China
| | - Bo Ma
- Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101, China
| | - Qinglin Song
- Qingdao Goertek Microelectronics Research Institute Co., Ltd., Qingdao 266104, China
| | - Dewen Tian
- Qingdao Goertek Microelectronics Research Institute Co., Ltd., Qingdao 266104, China
| | - Frederik Ceyssens
- ESAT-MICAS, KU Leuven, Kasteelpark Arenberg 10, B-3001 Leuven, Belgium
| | - Robert Puers
- ESAT-MICAS, KU Leuven, Kasteelpark Arenberg 10, B-3001 Leuven, Belgium
| | - Michael Kraft
- ESAT-MICAS, KU Leuven, Kasteelpark Arenberg 10, B-3001 Leuven, Belgium
| | - Weisheng Zhao
- School of Microelectronics, Beihang University, Beijing 100191, China; (X.W.)
- Beihang-Goertek Joint Microelectronics Institute, Qingdao Research Institute, Beihang University, Qingdao 266104, China
| | - Lianggong Wen
- School of Microelectronics, Beihang University, Beijing 100191, China; (X.W.)
- Beihang-Goertek Joint Microelectronics Institute, Qingdao Research Institute, Beihang University, Qingdao 266104, China
| |
Collapse
|
45
|
Ayala-Mar S, Perez-Gonzalez VH, Mata-Gómez MA, Gallo-Villanueva RC, González-Valdez J. Electrokinetically Driven Exosome Separation and Concentration Using Dielectrophoretic-Enhanced PDMS-Based Microfluidics. Anal Chem 2019; 91:14975-14982. [DOI: 10.1021/acs.analchem.9b03448] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Sergio Ayala-Mar
- Tecnologico de Monterrey, School of Engineering and Science, Av. Eugenio Garza Sada 2501, Monterrey, NL 64849, Mexico
| | - Victor H. Perez-Gonzalez
- Tecnologico de Monterrey, School of Engineering and Science, Av. Eugenio Garza Sada 2501, Monterrey, NL 64849, Mexico
| | - Marco A. Mata-Gómez
- Tecnologico de Monterrey, School of Engineering and Science, Av. Eugenio Garza Sada 2501, Monterrey, NL 64849, Mexico
| | - Roberto C. Gallo-Villanueva
- Tecnologico de Monterrey, School of Engineering and Science, Av. Eugenio Garza Sada 2501, Monterrey, NL 64849, Mexico
| | - José González-Valdez
- Tecnologico de Monterrey, School of Engineering and Science, Av. Eugenio Garza Sada 2501, Monterrey, NL 64849, Mexico
| |
Collapse
|
46
|
Abstract
Cancer drug resistance mechanisms such as tumor heterogeneity and adaptable feedback loops are prevalent issues facing cancer therapy development. Drug resistance can be unique to a cancer type and, most importantly, to each individual cancer patient. Consequently, testing different dosages and therapeutics directly on each individual patient sample (i.e., tumor and cancer cells) has compelling advantages compared to large scale in vitro drug testing and is a step toward personalized drug selection and effective treatment development. Recently, microfluidic-based chemo-sensitivity assays on patient biopsies have been proposed. Despite their novelty, these platforms usually rely on optical labels, optical equipment, or complex microfabricated channel geometries and structures. In this work, we proposed a novel lab on a chip platform capable of real-time and continuous screening of drug efficacy on (cancer) cell subpopulations without the need of labels or bulky readout optical equipment. In this platform, several label-free and rapid techniques have been implemented for the precise capturing of cells of interest in parallel with the real-time measurement and characterization of the effectiveness of candidate therapeutic agents. To demonstrate the utility of the platform, the effect of an apoptotic inducer, topoisomerase I inhibitor, 7-ethyl-10-hydrocamptothecin (SN38) on human colorectal carcinoma cancer cells (HCT 116) was used as a study model. Additionally, electrical results were optically verified to examine the continuous measurements of the biological mechanisms, specifically, apoptosis and necrosis, during therapeutic agent characterizations. The proposed device is a versatile platform which can also be easily redesigned for the automated and arrayed analysis of cell-drug interaction down to the single cell level. Our platform is another step toward enabling the personalized screening of drug efficacy on individual patients' samples that potentially leads to a better understanding of drug resistance and the optimization of patients' treatments.
Collapse
Affiliation(s)
- Vanessa Velasco
- Biochemistry Department , Stanford University , Palo Alto , California 94305 , United States
| | - Kushal Joshi
- Department of Biomedical Engineering , University of California Irvine , Irvine , California 92617 , United States
| | - Jiamin Chen
- Department of Medicine, Division of Oncology , Stanford University School of Medicine , Palo Alto , California 94305 , United States
| | - Rahim Esfandyarpour
- Department of Electrical Engineering , University of California Irvine , Irvine , California 92617 , United States.,Department of Biomedical Engineering , University of California Irvine , Irvine , California 92617 , United States.,Henry Samueli School of Engineering , University of California Irvine , Irvine , California 92617 , United States
| |
Collapse
|
47
|
Punjiya M, Nejad HR, Mathews J, Levin M, Sonkusale S. A flow through device for simultaneous dielectrophoretic cell trapping and AC electroporation. Sci Rep 2019; 9:11988. [PMID: 31427614 PMCID: PMC6700080 DOI: 10.1038/s41598-019-48198-x] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Accepted: 07/30/2019] [Indexed: 02/06/2023] Open
Abstract
Isolation of cells and their transfection in a controlled manner is an integral step in cell biotechnology. Electric field approaches such as dielectrophoresis (DEP) offers a more viable method for targeted immobilization of cells without any labels. For transfection of cells to incorporate exogenous materials, electrical methods such as electroporation, are preferred over chemical and viral delivery methods since they minimally affect cell viability and can target many types. However prior approaches to both methods required multiple excitation sources, an AC source for DEP-based trapping and another DC source for electroporation. In this paper, we present a first of its kind flow through lab-on-chip platform using a single AC excitation source for combined trapping using negative dielectrophoresis (nDEP) and AC electroporation. Use of AC fields for electroporation eliminates the unwanted side effects of electrolysis or joule heating at electrodes compared to DC electroporation. Adjusting the flow rate and the electrical parameters of the incident AC field precisely controls the operation (trap, trap with electroporation and release). The platform has been validated through trapping and simultaneous transfection of HEK-293 embryonic kidney cells with a plasmid vector containing a fluorescent protein tag. Numerical scaling analysis is provided that indicates promise for individual cell trapping and electroporation using low voltage AC fields.
Collapse
Affiliation(s)
- Meera Punjiya
- Tufts University, Department of Electrical and Computer Engineering, 161 College Ave, Medford, MA, 02155, USA.,Nano Lab, Advanced Technology Laboratory, 200 Boston Ave, Medford, MA, 02155, USA
| | - Hojatollah Rezaei Nejad
- Tufts University, Department of Electrical and Computer Engineering, 161 College Ave, Medford, MA, 02155, USA.,Nano Lab, Advanced Technology Laboratory, 200 Boston Ave, Medford, MA, 02155, USA
| | - Juanita Mathews
- Allen Discovery Center at Tufts University, Department of Biology, Medford, MA, 02155, USA
| | - Michael Levin
- Allen Discovery Center at Tufts University, Department of Biology, Medford, MA, 02155, USA
| | - Sameer Sonkusale
- Tufts University, Department of Electrical and Computer Engineering, 161 College Ave, Medford, MA, 02155, USA. .,Nano Lab, Advanced Technology Laboratory, 200 Boston Ave, Medford, MA, 02155, USA.
| |
Collapse
|
48
|
Al-Ahdal SA, Ahmad Kayani AB, Md Ali MA, Chan JY, Ali T, Adnan N, Buyong MR, Mhd Noor EE, Majlis BY, Sriram S. Dielectrophoresis of Amyloid-Beta Proteins as a Microfluidic Template for Alzheimer's Research. Int J Mol Sci 2019; 20:ijms20143595. [PMID: 31340481 PMCID: PMC6678832 DOI: 10.3390/ijms20143595] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2019] [Revised: 04/25/2019] [Accepted: 04/26/2019] [Indexed: 01/13/2023] Open
Abstract
We employed dielectrophoresis to a yeast cell suspension containing amyloid-beta proteins (Aβ) in a microfluidic environment. The Aβ was separated from the cells and characterized using the gradual dissolution of Aβ as a function of the applied dielectrophoretic parameters. We established the gradual dissolution of Aβ under specific dielectrophoretic parameters. Further, Aβ in the fibril form at the tip of the electrode dissolved at high frequency. This was perhaps due to the conductivity of the suspending medium changing according to the frequency, which resulted in a higher temperature at the tips of the electrodes, and consequently in the breakdown of the hydrogen bonds. However, those shaped as spheroidal monomers experienced a delay in the Aβ fibril transformation process. Yeast cells exposed to relatively low temperatures at the base of the electrode did not experience a positive or negative change in viability. The DEP microfluidic platform incorporating the integrated microtip electrode array was able to selectively manipulate the yeast cells and dissolve the Aβ to a controlled extent. We demonstrate suitable dielectrophoretic parameters to induce such manipulation, which is highly relevant for Aβ-related colloidal microfluidic research and could be applied to Alzheimer’s research in the future.
Collapse
Affiliation(s)
- Salman Ali Al-Ahdal
- Faculty of Engineering and Technology, Multimedia University, Melaka 75450, Malaysia
| | - Aminuddin Bin Ahmad Kayani
- Faculty of Engineering and Technology, Multimedia University, Melaka 75450, Malaysia.
- Functional Materials and Microsystems Research Group and the Micro Nano Research Facility, RMIT University, Melbourne, Victoria 3001, Australia.
| | - Mohd Anuar Md Ali
- Institute of Microengineering and Nanoelectronics, Universiti Kebangsaan Malaysia, Bangi, Selangor 43600, Malaysia
| | - Jun Yuan Chan
- Faculty of Engineering and Technology, Multimedia University, Melaka 75450, Malaysia
| | - Talal Ali
- Faculty of Medicine, International University of Africa, Khartoum 12223, Sudan
| | - Norah Adnan
- Faculty of Medicine, International University of Africa, Khartoum 12223, Sudan
| | - Muhamad Ramdzan Buyong
- Institute of Microengineering and Nanoelectronics, Universiti Kebangsaan Malaysia, Bangi, Selangor 43600, Malaysia
| | - Ervina Efzan Mhd Noor
- Faculty of Engineering and Technology, Multimedia University, Melaka 75450, Malaysia
| | - Burhanuddin Yeop Majlis
- Institute of Microengineering and Nanoelectronics, Universiti Kebangsaan Malaysia, Bangi, Selangor 43600, Malaysia
| | - Sharath Sriram
- Functional Materials and Microsystems Research Group and the Micro Nano Research Facility, RMIT University, Melbourne, Victoria 3001, Australia
| |
Collapse
|
49
|
DEP-on-a-Chip: Dielectrophoresis Applied to Microfluidic Platforms. MICROMACHINES 2019; 10:mi10060423. [PMID: 31238556 PMCID: PMC6630590 DOI: 10.3390/mi10060423] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 06/15/2019] [Accepted: 06/19/2019] [Indexed: 01/09/2023]
Abstract
Dielectric particles in a non-uniform electric field are subject to a force caused by a phenomenon called dielectrophoresis (DEP). DEP is a commonly used technique in microfluidics for particle or cell separation. In comparison with other separation methods, DEP has the unique advantage of being label-free, fast, and accurate. It has been widely applied in microfluidics for bio-molecular diagnostics and medical and polymer research. This review introduces the basic theory of DEP, its advantages compared with other separation methods, and its applications in recent years, in particular, focusing on the different electrode types integrated into microfluidic chips, fabrication techniques, and operation principles.
Collapse
|
50
|
Ozawa R, Iwadate H, Toyoda H, Yamada M, Seki M. A numbering-up strategy of hydrodynamic microfluidic filters for continuous-flow high-throughput cell sorting. LAB ON A CHIP 2019; 19:1828-1837. [PMID: 30998230 DOI: 10.1039/c9lc00053d] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Even though a number of microfluidic systems for particle/cell sorting have been proposed, facile and versatile platforms that provide sufficient sorting throughput and good operability are still under development. Here we present a simple but effective numbering-up strategy to dramatically increase the throughput of a continuous-flow particle/cell sorting scheme based on hydrodynamic filtration (HDF). A microfluidic channel equipped with multiple branches has been employed as a unit structure for size-based filtration, which realizes precise sorting without necessitating sheath flows. According to the concept of resistive circuit models, we designed and fabricated microdevices incorporating 64 or 128 closely assembled, multiplied units with a separation size of 5.0/7.0 μm. In proof-of-concept experiments, we successfully separated single micrometer-sized model particles and directly separated blood cells (erythrocytes and leukocytes) from blood samples. Additionally, we further increased the unit numbers by laminating multiple layers at a processing speed of up to 15 mL min-1. The presented numbering-up strategy would provide a valuable insight that is universally applicable to general microfluidic particle/cell sorters and may facilitate the actual use of microfluidic systems in biological studies and clinical diagnosis.
Collapse
Affiliation(s)
- Ryoken Ozawa
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan.
| | | | | | | | | |
Collapse
|