1
|
Bacteriophage-based nano-biosensors for the fast impedimetric determination of pathogens in food samples. Sci Rep 2023; 13:3498. [PMID: 36859463 PMCID: PMC9977096 DOI: 10.1038/s41598-023-30520-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 02/24/2023] [Indexed: 03/03/2023] Open
Abstract
The early and rapid detection of pathogenic microorganisms is of critical importance in addressing serious public health issues. Here, a new bacteriophage-based nano-biosensor was constructed and the electrochemical impedimetric method was fully optimized and applied for the quantitative detection of Escherichia coli O157:H7 in food samples. The impact of using a nanocomposite consisting of gold nanoparticles (AuNPs), multi-walled carbon nanotubes (MWCNTs), and tungsten oxide nanostructures (WO3) on the electrochemical performance of disposable screen printed electrodes was identified using the cyclic voltammetry and electrochemical impedance spectroscopy. The use nanomaterials enabled high capturing sensitivity against the targeting bacterial host cells with the limit of detection of 3.0 CFU/ml. Moreover, selectivity of the covalently immobilized active phage was tested against several non-targeting bacterial strains, where a high specificity was achieved. Thus, the targeting foodborne pathogen was successfully detected in food samples with high specificity, and the sensor provided an excellent recovery rate ranging from 90.0 to 108%. Accordingly, the newly developed phage-biosensor is recommended as a disposable label-free impedimetric biosensor for the quick and real-time monitoring of food quality.
Collapse
|
2
|
Hassan RYA. Advances in Electrochemical Nano-Biosensors for Biomedical and Environmental Applications: From Current Work to Future Perspectives. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22197539. [PMID: 36236638 PMCID: PMC9573286 DOI: 10.3390/s22197539] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/26/2022] [Accepted: 09/30/2022] [Indexed: 05/17/2023]
Abstract
Modern life quality is strongly supported by the advances made in biosensors, which has been attributed to their crucial and viable contribution in point-of-care (POC) technology developments. POC devices are exploited for the fast tracing of disease progression, rapid analysis of water, and food quality assessment. Blood glucose meters, home pregnancy strips, and COVID-19 rapid tests all represent common examples of successful biosensors. Biosensors can provide great specificity due to the incorporation of selective bio-recognition elements and portability at significantly reduced costs. Electrochemical biosensor platforms are one of the most advantageous of these platforms because they offer many merits, such as being cheap, selective, specific, rapid, and portable. Furthermore, they can be incorporated into smartphones and various analytical approaches in order to increase their sensitivity and many other properties. As a very broad and interdisciplinary area of research and development, biosensors include all disciplines and backgrounds from materials science, chemistry, physics, medicine, microbiology/biology, and engineering. Accordingly, in this state-of-the-art article, historical background alongside the long journey of biosensing construction and development, starting from the Clark oxygen electrode until reaching highly advanced wearable stretchable biosensing devices, are discussed. Consequently, selected examples among the miscellaneous applications of nanobiosensors (such as microbial detection, cancer diagnosis, toxicity analysis, food quality-control assurance, point of care, and health prognosis) are described. Eventually, future perspectives for intelligent biosensor commercialization and exploitation in real-life that is going to be supported by machine learning and artificial intelligence (AI) are stated.
Collapse
Affiliation(s)
- Rabeay Y. A. Hassan
- Applied Organic Chemistry Department, National Research Centre Dokki, Cairo 12622, Egypt; ; Tel.: +20-11292-16152
- Nanoscience Program, University of Science and Technology (UST), Zewail City of Science and Technology, Giza 12578, Egypt
| |
Collapse
|
3
|
Ashur I, Alter J, Werbner M, Ogungbile A, Dessau M, Gal-Tanamy M, Vernick S. Rapid electrochemical immunodetection of SARS-CoV-2 using a pseudo-typed vesicular stomatitis virus model. Talanta 2022; 239:123147. [PMID: 34920254 PMCID: PMC8667521 DOI: 10.1016/j.talanta.2021.123147] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 11/08/2021] [Accepted: 12/11/2021] [Indexed: 01/06/2023]
Abstract
The COVID-19 pandemic has highlighted the need for reliable and accurate diagnostic tools that provide quantitative results at the point of care. Real-time RT-PCR requires large laboratories, a skilled workforce, complex and costly equipment, and labor-intensive sample processing. Despite tremendous efforts, scaling up RT-PCR tests is seemingly unattainable. To date, hundreds of millions of COVID-19 tests have been performed globally, but the demand for timely, accurate testing continues to outstrip supply. Antigen-based rapid diagnostic testing is emerging as an alternative to RT-PCR. However, the performance of these tests, namely their sensitivity, is still inadequate. To overcome the limitations of currently employed diagnostic tests, new tools that are both sensitive and scalable are urgently needed. We have developed a miniaturized electrochemical biosensor based on the integration of specific monoclonal antibodies with a biochip and a measurement platform, and applied it in the detection of Spike S1 protein, the binding protein of SARS-CoV-2. Using electrochemical impedance spectroscopy, quantitative detection of sub-nanomolar concentrations of Spike S1 was demonstrated, exhibiting a broad detection range. To demonstrate the applicability of the biosensor, we have further developed a SARS-CoV-2 pseudovirus based on Spike protein-pseudo-typed VSV platform. Specific detection of different concentrations of pseudovirus particles was feasible in <30 min. This new tool may largely contribute to the fight against COVID-19 by enabling intensive testing to be performed and alleviating most of the hurdles that plague current diagnostics.
Collapse
Affiliation(s)
- Idan Ashur
- Department of Sensing, Information and Mechanization Engineering, Institute of Agricultural Engineering, ARO Volcani Center, 68 Hamaccabim Rd, Rishon lezion, 5025001, Israel.
| | - Joel Alter
- The Laboratory of Structural Biology of Infectious Diseases, The Azrieli Faculty of Medicine, Bar-Ilan University, Safed, Israel.
| | - Michal Werbner
- Molecular Virology Lab, The Azrieli Faculty of Medicine, Bar-Ilan University, Safed, Israel.
| | - Abraham Ogungbile
- Department of Sensing, Information and Mechanization Engineering, Institute of Agricultural Engineering, ARO Volcani Center, 68 Hamaccabim Rd, Rishon lezion, 5025001, Israel; Department of Soil and Water Sciences, Robert H. Smith Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, P.O. Box 12, Rehovot, 761001, Israel.
| | - Moshe Dessau
- The Laboratory of Structural Biology of Infectious Diseases, The Azrieli Faculty of Medicine, Bar-Ilan University, Safed, Israel.
| | - Meital Gal-Tanamy
- Molecular Virology Lab, The Azrieli Faculty of Medicine, Bar-Ilan University, Safed, Israel.
| | - Sefi Vernick
- Department of Sensing, Information and Mechanization Engineering, Institute of Agricultural Engineering, ARO Volcani Center, 68 Hamaccabim Rd, Rishon lezion, 5025001, Israel.
| |
Collapse
|
4
|
Boruleva EA, Nagovitsyn IA, Chudinova GK, Lobanov AV. Effect of DNA on the Fluorescence of ZnO Composite Films Containing Nanosized Diamonds. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY B 2022. [DOI: 10.1134/s1990793121060026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
5
|
Chang AY, Siddiqui S, Arumugam PU. Nafion and Multiwall Carbon Nanotube Modified Ultrananocrystalline Diamond Microelectrodes for Detection of Dopamine and Serotonin. MICROMACHINES 2021; 12:523. [PMID: 34066363 PMCID: PMC8148102 DOI: 10.3390/mi12050523] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Revised: 04/28/2021] [Accepted: 05/03/2021] [Indexed: 01/21/2023]
Abstract
Neurochemicals play a critical role in the function of the human brain in healthy and diseased states. Here, we have investigated three types of microelectrodes, namely boron-doped ultrananocrystalline diamond (BDUNCD), nafion-modified BDUNCD, and nafion-multi-walled carbon nanotube (MWCNT)-modified BDUNCD microelectrodes for long-term neurochemical detection. A ~50 nm-thick nafion-200-nm-thick MWCNT-modified BDUNCD microelectrode provided an excellent combination of sensitivity and selectivity for the detection of dopamine (DA; 6.75 μA μM-1 cm-2) and serotonin (5-HT; 4.55 μA μM-1 cm-2) in the presence of excess amounts of ascorbic acid (AA), the most common interferent. Surface stability studies employing droplet-based microfluidics demonstrate rapid response time (<2 s) and low limits of detection (5.4 ± 0.40 nM). Furthermore, we observed distinguishable DA and 5-HT current peaks in a ternary mixture during long-term stability studies (up to 9 h) with nafion-MWCNT-modified BDUNCD microelectrodes. Reduced fouling on the modified BDUNCD microelectrode surface offers significant advantages for their use in long-term neurochemical detection as compared to those of prior-art microelectrodes.
Collapse
Affiliation(s)
- An-Yi Chang
- Institute for Micromanufacturing (IfM), Louisiana Tech University, Ruston, LA 71272, USA;
- Center for Biomedical Engineering and Rehabilitation Science (CBERS), Louisiana Tech University, Ruston, LA 71272, USA
| | - Shabnam Siddiqui
- Department of Chemistry and Physics, Louisiana State University Shreveport, Shreveport, LA 71115, USA;
| | - Prabhu U. Arumugam
- Institute for Micromanufacturing (IfM), Louisiana Tech University, Ruston, LA 71272, USA;
- Center for Biomedical Engineering and Rehabilitation Science (CBERS), Louisiana Tech University, Ruston, LA 71272, USA
| |
Collapse
|
6
|
Hillman Y, Gershberg J, Lustiger D, Even D, Braverman D, Dror Y, Ashur I, Vernick S, Sal-Man N, Wine Y. Monoclonal Antibody-Based Biosensor for Point-of-Care Detection of Type III Secretion System Expressing Pathogens. Anal Chem 2020; 93:928-935. [DOI: 10.1021/acs.analchem.0c03621] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Yaron Hillman
- The Shmunis School of Biomedicine and Cancer Research, George S. Wise Faculty of Life Sciences, Green building, Tel-Aviv University, Tel Aviv 6997801, Israel
| | - Jenia Gershberg
- Department of Microbiology, Immunology and Genetics, Faculty of Health Sciences, Ben-Gurion University of the Negev, P.O. Box 653, Beer Sheva 8410501, Israel
| | - Dan Lustiger
- The Shmunis School of Biomedicine and Cancer Research, George S. Wise Faculty of Life Sciences, Green building, Tel-Aviv University, Tel Aviv 6997801, Israel
| | - Dan Even
- The Shmunis School of Biomedicine and Cancer Research, George S. Wise Faculty of Life Sciences, Green building, Tel-Aviv University, Tel Aviv 6997801, Israel
| | - Dor Braverman
- Department of Microbiology, Immunology and Genetics, Faculty of Health Sciences, Ben-Gurion University of the Negev, P.O. Box 653, Beer Sheva 8410501, Israel
| | - Yael Dror
- The Shmunis School of Biomedicine and Cancer Research, George S. Wise Faculty of Life Sciences, Green building, Tel-Aviv University, Tel Aviv 6997801, Israel
| | - Idan Ashur
- Institute of Agricultural Engineering, Agricultural Research Organization, Volcani Center, 68 Hamaccabim Rd, Rishon Lezion 5025001, Israel
| | - Sefi Vernick
- Institute of Agricultural Engineering, Agricultural Research Organization, Volcani Center, 68 Hamaccabim Rd, Rishon Lezion 5025001, Israel
| | - Neta Sal-Man
- Department of Microbiology, Immunology and Genetics, Faculty of Health Sciences, Ben-Gurion University of the Negev, P.O. Box 653, Beer Sheva 8410501, Israel
| | - Yariv Wine
- The Shmunis School of Biomedicine and Cancer Research, George S. Wise Faculty of Life Sciences, Green building, Tel-Aviv University, Tel Aviv 6997801, Israel
| |
Collapse
|
7
|
Cesewski E, Johnson BN. Electrochemical biosensors for pathogen detection. Biosens Bioelectron 2020; 159:112214. [PMID: 32364936 PMCID: PMC7152911 DOI: 10.1016/j.bios.2020.112214] [Citation(s) in RCA: 380] [Impact Index Per Article: 95.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Revised: 04/09/2020] [Accepted: 04/10/2020] [Indexed: 12/19/2022]
Abstract
Recent advances in electrochemical biosensors for pathogen detection are reviewed. Electrochemical biosensors for pathogen detection are broadly reviewed in terms of transduction elements, biorecognition elements, electrochemical techniques, and biosensor performance. Transduction elements are discussed in terms of electrode material and form factor. Biorecognition elements for pathogen detection, including antibodies, aptamers, and imprinted polymers, are discussed in terms of availability, production, and immobilization approach. Emerging areas of electrochemical biosensor design are reviewed, including electrode modification and transducer integration. Measurement formats for pathogen detection are classified in terms of sample preparation and secondary binding steps. Applications of electrochemical biosensors for the detection of pathogens in food and water safety, medical diagnostics, environmental monitoring, and bio-threat applications are highlighted. Future directions and challenges of electrochemical biosensors for pathogen detection are discussed, including wearable and conformal biosensors, detection of plant pathogens, multiplexed detection, reusable biosensors for process monitoring applications, and low-cost, disposable biosensors.
Collapse
Affiliation(s)
- Ellen Cesewski
- Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA; Department of Materials Science and Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Blake N Johnson
- Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA; Department of Materials Science and Engineering, Virginia Tech, Blacksburg, VA, 24061, USA; Department of Chemical Engineering, Virginia Tech, Blacksburg, VA, 24061, USA.
| |
Collapse
|
8
|
Sopoušek J, Věžník J, Skládal P, Lacina K. Blocking the Nanopores in a Layer of Nonconductive Nanoparticles: Dominant Effects Therein and Challenges for Electrochemical Impedimetric Biosensing. ACS APPLIED MATERIALS & INTERFACES 2020; 12:14620-14628. [PMID: 32134623 DOI: 10.1021/acsami.0c02650] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Blockage of a nanopore by an analyte molecule has emerged as a promising concept for electrochemical biosensing. Nanoporous structures can be formed on the electrode surface simply by packing spherical nanoparticles in a dense planar arrangement. Modification of the nanoparticles with human serum albumin (HSA) and its interaction with the corresponding antibody (anti-HSA) can induce nanopore-blockage which significantly hinders permeation of the redox probe ([Fe(CN6)]4-/3-). Interfaces of different parameters were studied using Electrochemical Impedance Spectroscopy (EIS), and counterintuitively, the influence of charge of the nanoparticles and other immobilized entities played a substantial role in the measurement. Our study reveals dominant effects including the presence of mixed output signal and resolves corresponding EIS biosensing-related challenges. Consequently, blocking the nanopores was introduced as an efficient technique which enables the application of EIS-based biosensing to real-world analytical issues.
Collapse
Affiliation(s)
- Jakub Sopoušek
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 753/5 625 00, Brno, Czech Republic
- Central European Institute of Technology CEITEC, Masaryk University, Kamenice 753/5 625 00, Brno, Czech Republic
| | - Jakub Věžník
- Central European Institute of Technology CEITEC, Masaryk University, Kamenice 753/5 625 00, Brno, Czech Republic
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5 625 00, Brno, Czech Republic
| | - Petr Skládal
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 753/5 625 00, Brno, Czech Republic
- Central European Institute of Technology CEITEC, Masaryk University, Kamenice 753/5 625 00, Brno, Czech Republic
| | - Karel Lacina
- Central European Institute of Technology CEITEC, Masaryk University, Kamenice 753/5 625 00, Brno, Czech Republic
| |
Collapse
|
9
|
Johnstone GE, Cairns GS, Patton BR. Nanodiamonds enable adaptive-optics enhanced, super-resolution, two-photon excitation microscopy. ROYAL SOCIETY OPEN SCIENCE 2019; 6:190589. [PMID: 31417755 PMCID: PMC6689623 DOI: 10.1098/rsos.190589] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Accepted: 07/04/2019] [Indexed: 06/10/2023]
Abstract
Particles of diamond in the 5-100 nm size range, known as nanodiamond (ND), have shown promise as robust fluorophores for optical imaging. We demonstrate here that, due to their photostability, they are not only suitable for two-photon imaging, but also allow significant resolution enhancement when combined with computational super-resolution techniques. We observe a resolution of 42.5 nm when processing two-photon images with the Super-Resolution Radial Fluctuations algorithm. We show manipulation of the point-spread function of the microscope using adaptive optics. This demonstrates how the photostability of ND can also be of use when characterizing adaptive optics technologies or testing the resilience of super-resolution or aberration correction algorithms.
Collapse
Affiliation(s)
| | | | - Brian R. Patton
- Department of Physics and SUPA, University of Strathclyde, Glasgow G4 0NG, UK
| |
Collapse
|
10
|
Chang AY, Dutta G, Siddiqui S, Arumugam PU. Surface Fouling of Ultrananocrystalline Diamond Microelectrodes during Dopamine Detection: Improving Lifetime via Electrochemical Cycling. ACS Chem Neurosci 2019; 10:313-322. [PMID: 30285418 DOI: 10.1021/acschemneuro.8b00257] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
In this work, we report the electrochemical response of a boron-doped ultrananocrystalline diamond (BDUNCD) microelectrode during long-term dopamine (DA) detection. Specifically, changes to its electrochemical activity and electroactive area due to DA byproducts and surface oxidation are studied via scanning electron microscopy, energy dispersive spectroscopy, electrochemical impedance spectroscopy, and silver deposition imaging (SDI). The fouling studies with amperometry (AM) and fast scan cyclic voltammetry (FSCV) methods suggest that the microelectrodes are heavily fouled due to poor DA-dopamine- o-quinone cyclization rates followed by a combination of polymer formation and major changes in their surface chemistry. SDI data confirms the presence of the insulating polymer with sparsely distributed tiny electroactive regions. This resulted in severely distorted DA signals and a 90% loss in signal starting as early as 3 h for AM and a 56% loss at 6.5 h for FSCV. This underscores the need for cleaning of the fouled microelectrodes if they have to be used long-term. Out of the three in vivo suitable electrochemical cycling cleaning waveforms investigated, the standard waveform (-0.4 V to +1.0 V) provides the best cleaned surface with a fully retained voltammogram shape, no hysteresis, no DA signal loss (a 90 ± 0.72 nA increase), and the smallest charge transfer resistance value of 0.4 ± 0.02 MΩ even after 6.5 h of monitoring. Most importantly, this is the same waveform that is widely used for in vivo detection with carbon fiber microelectrodes. Future work to test these microelectrodes for more than 24 h of DA detection is anticipated.
Collapse
Affiliation(s)
- An-Yi Chang
- Institute for Micromanufacturing, Louisiana Tech University, 911 Hergot Avenue, Ruston, Louisiana 71272, United States
| | - Gaurab Dutta
- Institute for Micromanufacturing, Louisiana Tech University, 911 Hergot Avenue, Ruston, Louisiana 71272, United States
| | - Shabnam Siddiqui
- Institute for Micromanufacturing, Louisiana Tech University, 911 Hergot Avenue, Ruston, Louisiana 71272, United States
| | - Prabhu U. Arumugam
- Institute for Micromanufacturing, Louisiana Tech University, 911 Hergot Avenue, Ruston, Louisiana 71272, United States
| |
Collapse
|
11
|
Yang N, Yu S, Macpherson JV, Einaga Y, Zhao H, Zhao G, Swain GM, Jiang X. Conductive diamond: synthesis, properties, and electrochemical applications. Chem Soc Rev 2019; 48:157-204. [DOI: 10.1039/c7cs00757d] [Citation(s) in RCA: 236] [Impact Index Per Article: 47.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
This review summarizes systematically the growth, properties, and electrochemical applications of conductive diamond.
Collapse
Affiliation(s)
- Nianjun Yang
- Institute of Materials Engineering
- University of Siegen
- Siegen 57076
- Germany
| | - Siyu Yu
- Institute of Materials Engineering
- University of Siegen
- Siegen 57076
- Germany
| | | | - Yasuaki Einaga
- Department of Chemistry
- Keio University
- Yokohama 223-8522
- Japan
| | - Hongying Zhao
- School of Chemical Science and Engineering
- Tongji University
- Shanghai 200092
- China
| | - Guohua Zhao
- School of Chemical Science and Engineering
- Tongji University
- Shanghai 200092
- China
| | | | - Xin Jiang
- Institute of Materials Engineering
- University of Siegen
- Siegen 57076
- Germany
| |
Collapse
|
12
|
Chen J, Kong L, Sun X, Feng J, Chen Z, Fan D, Wei Q. Ultrasensitive photoelectrochemical immunosensor of cardiac troponin I detection based on dual inhibition effect of Ag@Cu2O core-shell submicron-particles on CdS QDs sensitized TiO2 nanosheets. Biosens Bioelectron 2018; 117:340-346. [DOI: 10.1016/j.bios.2018.05.037] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Revised: 05/22/2018] [Accepted: 05/22/2018] [Indexed: 10/16/2022]
|
13
|
Tan C, Dutta G, Yin H, Siddiqui S, Arumugam PU. Detection of neurochemicals with enhanced sensitivity and selectivity via hybrid multiwall carbon nanotube-ultrananocrystalline diamond microelectrodes. SENSORS AND ACTUATORS. B, CHEMICAL 2018; 258:193-203. [PMID: 32528220 PMCID: PMC7289503 DOI: 10.1016/j.snb.2017.11.054] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Abnormal neurochemical signaling is often the underlying cause of brain disorders. Electrochemical microsensors are widely used to monitor neurochemicals with high spatial-temporal resolution. However, they rely on carbon fiber microelectrodes that often limit their sensing performance. In this study, we demonstrate the potential of a hybrid multiwall carbon nanotube (MWCNT) film modified boron-doped ultrananocrystalline diamond (UNCD) microelectrode (250 μm diameter) microsensor for improved detection of dopamine (DA) in the presence of common interferents. A series of modified microelectrodes with varying film thicknesses were microfabricated by electrophoretic deposition (EPD) and characterized by scanning electron microscopy, x-ray photoelectron spectroscopy, electrochemical impedance spectroscopy (EIS) and silver deposition imaging. Using cyclic voltammetry, the 100-nm "thin" film microelectrode produced the most favorable combination of DA sensitivity value of 36 ±2% μA/μM/cm2 with a linear range of 33 nM to 1 μM and a limit of detection (LOD) of 9.5 ± 1.2% nM. The EIS spectra of these microelectrodes revealed three regions with inhomogeneous pore geometry and differing impedance values and electrochemical activity, which was found to be film thickness dependent. Using differential pulse voltammetry, the modified microelectrode showed excellent selectivity by exhibiting three distinct peaks for the DA, serotonin and excess ascorbic acid in a ternary mixture. These results provide two key benefits: first, remarkable improvements in DA sensitivity (>125-fold), selectivity (>2000-fold) and LOD (>180-fold), second, these MWCNTs can be selectively coated with a simple, scalable and low cost EPD process for highly multiplexed microsensor technologies. These advances offer considerable promise for further progress in chemical neurosciences.
Collapse
|
14
|
Yang J, Zhang Y. Nanocrystalline Diamond Films Grown by Microwave Plasma Chemical Vapor Deposition and Its Biocompatible Property. ACTA ACUST UNITED AC 2018. [DOI: 10.4236/ampc.2018.84011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
15
|
Qiang T, Wang C, Kim NY. Quantitative detection of glucose level based on radiofrequency patch biosensor combined with volume-fixed structures. Biosens Bioelectron 2017; 98:357-363. [DOI: 10.1016/j.bios.2017.06.057] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2017] [Revised: 06/26/2017] [Accepted: 06/27/2017] [Indexed: 11/28/2022]
|
16
|
Akter R, Jeong B, Lee YM, Choi JS, Rahman MA. Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor. Biosens Bioelectron 2017; 91:637-643. [DOI: 10.1016/j.bios.2017.01.021] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2016] [Revised: 01/11/2017] [Accepted: 01/11/2017] [Indexed: 01/02/2023]
|
17
|
Broz A, Ukraintsev E, Kromka A, Rezek B, Hubalek Kalbacova M. Osteoblast adhesion, migration, and proliferation variations on chemically patterned nanocrystalline diamond films evaluated by live-cell imaging. J Biomed Mater Res A 2017; 105:1469-1478. [PMID: 27935192 DOI: 10.1002/jbm.a.35969] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Revised: 11/22/2016] [Accepted: 11/28/2016] [Indexed: 11/11/2022]
Abstract
Cell fate modulation by adapting the surface of a biocompatible material is nowadays a challenge in implantology, tissue engineering as well as in construction of biosensors. Nanocrystalline diamond (NCD) thin films are considered promising in these fields due to their extraordinary physical and chemical properties and diverse ways in which they can be modified structurally and chemically. The initial cell distribution, the rate of cell adhesion, distance of cell migration and also the cell proliferation are influenced by the NCD surface termination. Here, we use real-time live-cell imaging to investigate the above-mentioned processes on oxidized NCD (NCD-O) and hydrogenated NCD (NCD-H) to elucidate cell preference to the NCD-O especially on surfaces with microscopic surface termination patterns. Cells adhere more slowly and migrate farther on NCD-H than on NCD-O. Cells seeded with a fetal bovine serum (FBS) supplement in the medium move across the surface prior to adhesion. In the absence of FBS, the cells adhere immediately, but still exhibit different migration and proliferation on NCD-O/H regions. We discuss the impact of these effects on the formation of cell arrays on micropatterned NCD. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1469-1478, 2017.
Collapse
Affiliation(s)
- Antonin Broz
- Institute of Inherited Metabolic Disorders, Laboratory of Interaction of Cells with Nanomaterials, 1st Faculty of Medicine, Charles University in Prague, Ke Karlovu 2, 12853 Prague 2, Czech Republic.,Institute of Physiology, Department of Biomaterials and Tissue Engineering, Czech Academy of Sciences, v. v. i, Videnska 1083, 142 20, Prague 4, Czech Republic
| | - Egor Ukraintsev
- Institute of Physics, Department of Optical Materials, Czech Academy of Sciences, v. v. i, Cukrovarnicka 10, 162 53 Prague 6, Czech Republic
| | - Alexander Kromka
- Institute of Physics, Department of Optical Materials, Czech Academy of Sciences, v. v. i, Cukrovarnicka 10, 162 53 Prague 6, Czech Republic
| | - Bohuslav Rezek
- Institute of Physics, Department of Optical Materials, Czech Academy of Sciences, v. v. i, Cukrovarnicka 10, 162 53 Prague 6, Czech Republic.,Faculty of Electrical Engineering, Department of Physics, Czech Technical University, Technicka 2, 166 27 Prague 6, Czech Republic
| | - Marie Hubalek Kalbacova
- Institute of Inherited Metabolic Disorders, Laboratory of Interaction of Cells with Nanomaterials, 1st Faculty of Medicine, Charles University in Prague, Ke Karlovu 2, 12853 Prague 2, Czech Republic.,Biomedical Centre, Laboratory of Cell-Biomaterial Interactions, Faculty of Medicine in Pilsen, Charles University, alej Svobody 76, 323 00 Pilsen, Czech Republic
| |
Collapse
|
18
|
Dutta G, Tan C, Siddiqui S, Arumugam PU. Enabling long term monitoring of dopamine using dimensionally stable ultrananocrystalline diamond microelectrodes. MATERIALS RESEARCH EXPRESS 2016; 3:094001. [PMID: 32391160 PMCID: PMC7211381 DOI: 10.1088/2053-1591/3/9/094001] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Chronic dopamine (DA) monitoring is a critical enabling technology to identify the neural basis of human behavior. Carbon fiber microelectrodes (CFM), the current gold standard electrode for in vivo fast scan cyclic voltammetry (FSCV), rapidly loses sensitivity due to surface fouling during chronic neural testing. Periodic voltage excursions at elevated anodic potentials regenerate fouled CFM surfaces but they also chemically degrade the CFM surfaces. Here, we compare the dimensional stability of 150 μm boron-doped ultrananocrystalline diamond (BDUNCD) microelectrodes in 1X PBS during 'electrochemical cleaning' with a similar-sized CFM. Scanning electron microscopy and Raman spectroscopy confirm the exceptional dimensional stability of BDUNCD after 40 h of FSCV cycling (~8 million cycles). The fitting of electrochemical impedance spectroscopy data to an appropriate circuit model shows a 2x increase in charge transfer resistance and an additional RC element, which suggests oxidation of BDUNCD electrode surface. This could have likely increased the DA oxidation potential by ~34% to +308 mV. A 2x increase in BDUNCD grain capacitance and a negligible change in grain boundary impedance suggests regeneration of grains and the exposure of new grain boundaries, respectively. Overall, DA voltammogram signals were reduced by only ~20%. In contrast, the CFM is completely etched with a ~90% reduction in the DA signal using the same cleaning conditions. Thus, BDUNCD provides a robust electrode surface that is amenable to repeated and aggressive cleaning which could be used for chronic DA sensing.
Collapse
Affiliation(s)
- Gaurab Dutta
- Institute for Micromanufacturing, 911 Hergot Ave, Louisiana Tech University, Ruston, LA 71272, USA
| | - Chao Tan
- Institute for Micromanufacturing, 911 Hergot Ave, Louisiana Tech University, Ruston, LA 71272, USA
| | - Shabnam Siddiqui
- Institute for Micromanufacturing, 911 Hergot Ave, Louisiana Tech University, Ruston, LA 71272, USA
| | - Prabhu U Arumugam
- Institute for Micromanufacturing, 911 Hergot Ave, Louisiana Tech University, Ruston, LA 71272, USA
| |
Collapse
|
19
|
Ochratoxin A Detection on Antibody- Immobilized on BSA-Functionalized Gold Electrodes. PLoS One 2016; 11:e0160021. [PMID: 27467684 PMCID: PMC4965031 DOI: 10.1371/journal.pone.0160021] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Accepted: 07/12/2016] [Indexed: 11/21/2022] Open
Abstract
Ochratoxin A (OTA)—a toxin produced by Aspergillus carbonarius, Aspergillus ochraceus, and Penicillium verrucosum—is one of the most-abundant food-contaminating mycotoxins. To avoid the risk of OTA consumption for humans and animals, the rapid detection and quantitation of OTA level in different commodities are of great importance. In this work, an impedimetric immunosensor for ochratoxin A (OTA) detection, a common toxic botanical contaminant, was developed via the immobilization of anti-OTA antibody on bovine serum albumin modified gold electrodes. A four-step reaction protocol was tested to modify the gold electrode and obtain the sensing substrate. All the steps of the immunosensor elaboration and also the immunochemical reaction between surface-bound antibody and ochratoxin A were analyzed using cyclic voltammetry and electrochemical impedance spectroscopy. Modification of the impedance due to the specific antigen-antibody reaction at immunosensor surface, was used in order to detect ochratoxin A. Linear proportionality of the charge transfer resistance to the concentration of OTA allows ochratoxin A detection in the range of 2.5–100 ng/mL.
Collapse
|
20
|
Siddiqui S, Dutta G, Tan C, Arumugam PU. Nanocrystalline Diamond Electrodes: Enabling electrochemical microsensing applications with high reliability and stability. IEEE NANOTECHNOLOGY MAGAZINE 2016; 10:12-20. [PMID: 32457817 DOI: 10.1109/mnano.2016.2572243] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
THE DIAMOND (D) IS ONE OF the most precious materials in the world with unmatched physical and chemical properties, such as hardness, extreme chemical stability, high thermal conductivity, the highest acoustic velocity of any material, an extremely low friction coefficient when smooth, and nearly unmatched biocompatibility [1]. The carbon (C) atoms in Ds are tetrahedrally coordinated, i.e., each C atom is bonded to four others in the D lattice. This bonding is referred to as sp 3 bonding, and the strength and configuration of these bonds provide Ds with these unmatched fundamental properties and characteristics. Realizing these properties of the D in a C-based film that can easily be integrated into functional engineering systems and deployed in many applications has been a challenge for several decades. This is of primary concern in microelectronics, sensing, and hard-coating applications.
Collapse
|
21
|
Xu Y, Xie X, Duan Y, Wang L, Cheng Z, Cheng J. A review of impedance measurements of whole cells. Biosens Bioelectron 2016; 77:824-36. [DOI: 10.1016/j.bios.2015.10.027] [Citation(s) in RCA: 252] [Impact Index Per Article: 31.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2015] [Revised: 10/03/2015] [Accepted: 10/09/2015] [Indexed: 11/17/2022]
|
22
|
Dutta G, Siddiqui S, Zeng H, Carlisle JA, Arumugam PU. The effect of electrode size and surface heterogeneity on electrochemical properties of ultrananocrystalline diamond microelectrode. J Electroanal Chem (Lausanne) 2015; 756:61-68. [PMID: 32280318 PMCID: PMC7148118 DOI: 10.1016/j.jelechem.2015.08.016] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We report here the effect of electrode size on electrochemical properties of boron-doped ultrananocrystalline diamond (UNCD) microelectrodes using electrochemical impedance spectroscopy (EIS). By reducing microelectrode size from 250-μm to 10-μm diameter (D), the shape of impedance spectra changes from linear line to two-arcs. The fitting of experimental data to electrochemical circuit model suggests that each arc likely corresponds to UNCD grains and grain boundary phases. The two phases become separable as a result of microelectrode size reduction. In addition, for D ≤ 100-μm, microstructural and morphological defects/heterogeneities of grain boundaries and the presence of surface oxygen are also revealed in the spectra. The microelectrode size reduction specifically affect the impedance of the grain boundaries, e.g. for ultramicroelectrodes, UMEs (D ≤ 25-μm), as the grain boundary impedance increases by ~30-fold. Thus, at UMEs, the grain-grain boundary properties are revealed more sensitively in the spectra. Atomic force microscopy, scanning electron microscopy, Raman spectroscopy and surface profilometry measurements were performed to study the influence of microfabrication on surface properties. A significant increase in surface roughness after microfabrication shows that heterogeneities as observed in the spectra are not only due to intrinsic UNCD properties but also arises from microfabrication.
Collapse
Affiliation(s)
- Gaurab Dutta
- Institute for Micromanufacturing, 911 Hergot Ave, Louisiana Tech University, Ruston, LA 71272, USA
| | - Shabnam Siddiqui
- Institute for Micromanufacturing, 911 Hergot Ave, Louisiana Tech University, Ruston, LA 71272, USA
| | - Hongjun Zeng
- Advanced Diamond Technologies, 48E Belmont Drive, Romeoville, Illinois 60565, USA
| | - John A. Carlisle
- Advanced Diamond Technologies, 48E Belmont Drive, Romeoville, Illinois 60565, USA
| | - Prabhu U. Arumugam
- Institute for Micromanufacturing, 911 Hergot Ave, Louisiana Tech University, Ruston, LA 71272, USA
| |
Collapse
|
23
|
Nagl A, Hemelaar SR, Schirhagl R. Improving surface and defect center chemistry of fluorescent nanodiamonds for imaging purposes--a review. Anal Bioanal Chem 2015; 407:7521-36. [PMID: 26220715 PMCID: PMC4575388 DOI: 10.1007/s00216-015-8849-1] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Revised: 06/05/2015] [Accepted: 06/10/2015] [Indexed: 01/06/2023]
Abstract
Diamonds are widely used for jewelry owing to their superior optical properties accounting for their fascinating beauty. Beyond the sparkle, diamond is highly investigated in materials science for its remarkable properties. Recently, fluorescent defects in diamond, particularly the negatively charged nitrogen-vacancy (NV(-)) center, have gained much attention: The NV(-) center emits stable, nonbleaching fluorescence, and thus could be utilized in biolabeling, as a light source, or as a Förster resonance energy transfer donor. Even more remarkable are its spin properties: with the fluorescence intensity of the NV(-) center reacting to the presence of small magnetic fields, it can be utilized as a sensor for magnetic fields as small as the field of a single electron spin. However, a reproducible defect and surface and defect chemistry are crucial to all applications. In this article we review methods for using nanodiamonds for different imaging purposes. The article covers (1) dispersion of particles, (2) surface cleaning, (3) particle size selection and reduction, (4) defect properties, and (5) functionalization and attachment to nanostructures, e.g., scanning probe microscopy tips.
Collapse
Affiliation(s)
- Andreas Nagl
- University Medical Center Groningen, Groningen University, Antonius Deusinglaan 1, 9713 AW, Groningen, The Netherlands
| | - Simon Robert Hemelaar
- University Medical Center Groningen, Groningen University, Antonius Deusinglaan 1, 9713 AW, Groningen, The Netherlands
| | - Romana Schirhagl
- University Medical Center Groningen, Groningen University, Antonius Deusinglaan 1, 9713 AW, Groningen, The Netherlands.
| |
Collapse
|
24
|
Andrade CAS, Nascimento JM, Oliveira IS, de Oliveira CVJ, de Melo CP, Franco OL, Oliveira MDL. Nanostructured sensor based on carbon nanotubes and clavanin A for bacterial detection. Colloids Surf B Biointerfaces 2015; 135:833-839. [PMID: 25847459 DOI: 10.1016/j.colsurfb.2015.03.037] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2014] [Revised: 03/11/2015] [Accepted: 03/16/2015] [Indexed: 11/17/2022]
Abstract
Unusual methods for specific detection of pathogenic bacteria are becoming key points for control and identification of problems related to health and (bio)safety. In this context, this work aims to propose a new approach for the development of nanostructured biosensors based on carbon nanotubes (CNTs) and antimicrobial peptides for bacterial detection. Firstly, the antimicrobial peptide clavanin A (ClavA) was chemically immobilized on CNTs and surface-immobilized ClavA was used to detect Klebsiella pneumoniae, Enterococcus faecalis, Escherichia coli and Bacillus subtilis in a direct assay format. We used electrochemical impedance spectroscopy technique to evaluate the effectiveness and sensitivity of the ClavA-based biosensors by measuring the modifications in their electrochemical responses before and after incubation in presence of different bacteria concentrations. The biosensor was able to discriminate between bacteria concentrations in the 10(2)-10(6)CFU mL(-1) range. Atomic force microscopy analysis confirmed the biosensor functionality for bacterial recognition. This new sensor system was capable of differentiating between Gram-positive and Gram-negative bacteria, since ClavA showed different affinities toward the pathogenic bacteria species.
Collapse
Affiliation(s)
- César A S Andrade
- Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil; Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil.
| | - Jéssica M Nascimento
- Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil
| | - Idjane S Oliveira
- Centro Acadêmico de Vitória, Universidade Federal de Pernambuco, 55608-680 Vitória de Santo Antão, PE, Brazil
| | - Carlos V J de Oliveira
- Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil
| | - Celso P de Melo
- Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil
| | - Octávio L Franco
- Centro de Análise Proteômicas e Bioquímicas de Brasília, Universidade Católica de Brasília, Brasília, DF, Brazil; S-Inova, Pós-graduação em Biotecnologia, Universidade Católica Dom Bosco, Campo Grande, MS, Brazil
| | - Maria D L Oliveira
- Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil
| |
Collapse
|
25
|
Ahmed A, Rushworth JV, Hirst NA, Millner PA. Biosensors for whole-cell bacterial detection. Clin Microbiol Rev 2014; 27:631-46. [PMID: 24982325 PMCID: PMC4135896 DOI: 10.1128/cmr.00120-13] [Citation(s) in RCA: 349] [Impact Index Per Article: 34.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Bacterial pathogens are important targets for detection and identification in medicine, food safety, public health, and security. Bacterial infection is a common cause of morbidity and mortality worldwide. In spite of the availability of antibiotics, these infections are often misdiagnosed or there is an unacceptable delay in diagnosis. Current methods of bacterial detection rely upon laboratory-based techniques such as cell culture, microscopic analysis, and biochemical assays. These procedures are time-consuming and costly and require specialist equipment and trained users. Portable stand-alone biosensors can facilitate rapid detection and diagnosis at the point of care. Biosensors will be particularly useful where a clear diagnosis informs treatment, in critical illness (e.g., meningitis) or to prevent further disease spread (e.g., in case of food-borne pathogens or sexually transmitted diseases). Detection of bacteria is also becoming increasingly important in antibioterrorism measures (e.g., anthrax detection). In this review, we discuss recent progress in the use of biosensors for the detection of whole bacterial cells for sensitive and earlier identification of bacteria without the need for sample processing. There is a particular focus on electrochemical biosensors, especially impedance-based systems, as these present key advantages in terms of ease of miniaturization, lack of reagents, sensitivity, and low cost.
Collapse
Affiliation(s)
- Asif Ahmed
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| | - Jo V Rushworth
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| | - Natalie A Hirst
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| | - Paul A Millner
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| |
Collapse
|
26
|
Verma MS, Chen PZ, Jones L, Gu FX. "Chemical nose" for the visual identification of emerging ocular pathogens using gold nanostars. Biosens Bioelectron 2014; 61:386-90. [PMID: 24912040 DOI: 10.1016/j.bios.2014.05.045] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Revised: 05/16/2014] [Accepted: 05/19/2014] [Indexed: 10/25/2022]
Abstract
Ocular pathogens can cause serious damages in the eye leading to severe vision loss and even blindness if left untreated. Identification of pathogens is crucial for administering the appropriate antibiotics in order to gain effective control over ocular infection. Herein, we report a gold nanostar based "chemical nose" for visually identifying ocular pathogens. Using a spectrophotometer and nanostars of different sizes and degrees of branching, we show that the "chemical nose" is capable of identifying the following clinically relevant ocular pathogens with an accuracy of 99%: S. aureus, A. xylosoxidans, D. acidovorans and S. maltophilia. The differential colorimetric response is due to electrostatic aggregation of cationic gold nanostars around bacteria without the use of biomolecule ligands such as aptamers or antibodies. Transmission electron microscopy confirms that the number of gold nanostars aggregated around each bacterium correlates closely with the colorimetric response. Thus, gold nanostars serve as a promising platform for rapid visual identification of ocular pathogens with application in point-of-care diagnostics.
Collapse
Affiliation(s)
- Mohit S Verma
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue W, Waterloo, Ontario, Canada N2L 3G1; Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue W, Waterloo, Ontario, Canada N2L 3G1
| | - Paul Z Chen
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue W, Waterloo, Ontario, Canada N2L 3G1
| | - Lyndon Jones
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue W, Waterloo, Ontario, Canada N2L 3G1; Center for Contact Lens Research, University of Waterloo, 200 University Avenue W, Waterloo, Ontario, Canada N2L 3G1
| | - Frank X Gu
- Department of Chemical Engineering, University of Waterloo, 200 University Avenue W, Waterloo, Ontario, Canada N2L 3G1; Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue W, Waterloo, Ontario, Canada N2L 3G1.
| |
Collapse
|
27
|
Elshafey R, Tavares AC, Siaj M, Zourob M. Electrochemical impedance immunosensor based on gold nanoparticles–protein G for the detection of cancer marker epidermal growth factor receptor in human plasma and brain tissue. Biosens Bioelectron 2013; 50:143-9. [DOI: 10.1016/j.bios.2013.05.063] [Citation(s) in RCA: 108] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2013] [Revised: 05/28/2013] [Accepted: 05/29/2013] [Indexed: 02/08/2023]
|
28
|
Arumugam PU, Zeng H, Siddiqui S, Covey DP, Carlisle JA, Garris PA. Characterization of ultrananocrystalline diamond microsensors for in vivo dopamine detection. APPLIED PHYSICS LETTERS 2013; 102:253107. [PMID: 23918991 PMCID: PMC3710216 DOI: 10.1063/1.4811785] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2013] [Accepted: 06/01/2013] [Indexed: 05/18/2023]
Abstract
We show the technical feasibility of coating and micro patterning boron-doped ultrananocrystalline diamond (UNCD®) on metal microwires and of applying them as microsensors for the detection of dopamine in vivo using fast-scan cyclic voltammetry. UNCD electrode surface consistently generated electrochemical signals with high signal-to-noise ratio of >800 using potassium ferrocyanide-ferricyanide redox couple. Parylene patterned UNCD microelectrodes were effectively applied to detect dopamine reliably in vitro using flow injection analysis with a detection limit of 27 nM and in the striatum of the anesthetized rat during electrical stimulation of dopamine neurons.
Collapse
Affiliation(s)
- Prabhu U Arumugam
- Advanced Diamond Technologies, Inc., 48 E Belmont Drive, Romeoville, Illinois 60446, USA
| | | | | | | | | | | |
Collapse
|
29
|
Gao ZF, Gao JB, Zhou LY, Zhang Y, Si JC, Luo HQ, Li NB. Rapid assembly of ssDNA on gold electrode surfaces at low pH and high salt concentration conditions. RSC Adv 2013. [DOI: 10.1039/c3ra40810h] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
|
30
|
Johnson BN, Mutharasan R. Electrochemical piezoelectric-excited millimeter-sized cantilever (ePEMC) for simultaneous dual transduction biosensing. Analyst 2013; 138:6365-71. [DOI: 10.1039/c3an01353g] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
31
|
Dastider SG, Barizuddin S, Dweik M, Almasri M. A micromachined impedance biosensor for accurate and rapid detection of E. coli O157:H7. RSC Adv 2013. [DOI: 10.1039/c3ra44724c] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
32
|
van Belkum A, Durand G, Peyret M, Chatellier S, Zambardi G, Schrenzel J, Shortridge D, Engelhardt A, Dunne WM. Rapid clinical bacteriology and its future impact. Ann Lab Med 2012; 33:14-27. [PMID: 23301218 PMCID: PMC3535192 DOI: 10.3343/alm.2013.33.1.14] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2012] [Accepted: 10/10/2012] [Indexed: 02/01/2023] Open
Abstract
Clinical microbiology has always been a slowly evolving and conservative science. The sub-field of bacteriology has been and still is dominated for over a century by culture-based technologies. The integration of serological and molecular methodologies during the seventies and eighties of the previous century took place relatively slowly and in a cumbersome fashion. When nucleic acid amplification technologies became available in the early nineties, the predicted "revolution" was again slow but in the end a real paradigm shift did take place. Several of the culture-based technologies were successfully replaced by tests aimed at nucleic acid detection. More recently a second revolution occurred. Mass spectrometry was introduced and broadly accepted as a new diagnostic gold standard for microbial species identification. Apparently, the diagnostic landscape is changing, albeit slowly, and the combination of newly identified infectious etiologies and the availability of innovative technologies has now opened new avenues for modernizing clinical microbiology. However, the improvement of microbial antibiotic susceptibility testing is still lagging behind. In this review we aim to sketch the most recent developments in laboratory-based clinical bacteriology and to provide an overview of emerging novel diagnostic approaches.
Collapse
Affiliation(s)
- Alex van Belkum
- BioMérieux SA, Unit Microbiology, R&D Microbiology, La Balme Les Grottes, France
| | | | | | | | | | | | | | | | | |
Collapse
|