1
|
Pan Y, Zhang J, Guo X, Li Y, Li L, Pan L. Recent Advances in Conductive Polymers-Based Electrochemical Sensors for Biomedical and Environmental Applications. Polymers (Basel) 2024; 16:1597. [PMID: 38891543 PMCID: PMC11174834 DOI: 10.3390/polym16111597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 05/27/2024] [Accepted: 05/30/2024] [Indexed: 06/21/2024] Open
Abstract
Electrochemical sensors play a pivotal role in various fields, such as biomedicine and environmental detection, due to their exceptional sensitivity, selectivity, stability, rapid response time, user-friendly operation, and ease of miniaturization and integration. In addition to the research conducted in the application field, significant focus is placed on the selection and optimization of electrode interface materials for electrochemical sensors. The detection performance of these sensors can be significantly enhanced by modifying the interface of either inorganic metal electrodes or printed electrodes. Among numerous available modification materials, conductive polymers (CPs) possess not only excellent conductivity exhibited by inorganic conductors but also unique three-dimensional structural characteristics inherent to polymers. This distinctive combination allows CPs to increase active sites during the detection process while providing channels for rapid ion transmission and facilitating efficient electron transfer during reaction processes. This review article primarily highlights recent research progress concerning CPs as an ideal choice for modifying electrochemical sensors owing to their remarkable features that make them well-suited for biomedical and environmental applications.
Collapse
Affiliation(s)
- Youheng Pan
- College of Mechanical and Electrical Engineering, Henan Agricultural University, Zhengzhou 450002, China
| | - Jing Zhang
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| | - Xin Guo
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| | - Yarou Li
- College of Mechanical and Electrical Engineering, Henan Agricultural University, Zhengzhou 450002, China
| | - Lanlan Li
- College of Mechanical and Electrical Engineering, Henan Agricultural University, Zhengzhou 450002, China
| | - Lijia Pan
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| |
Collapse
|
2
|
Rafi J, Daniel M, Neppolian B. Ultrasensitive detection of chloramphenicol in water using functionalized polymers with an aluminium organic framework. CHEMOSPHERE 2024; 357:141981. [PMID: 38626813 DOI: 10.1016/j.chemosphere.2024.141981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 02/23/2024] [Accepted: 04/09/2024] [Indexed: 04/21/2024]
Abstract
Metal-Organic Frameworks (MOFs) are extensively used as electrode material in various sensing applications due to their efficacious porous nature and tunable properties. However, pristine MOFs lack conductive attributes that hinder their wide usage in electrochemical applications. Electropolymerization of several aromatic monomers has been a widely used strategy for preparing conducting electrode materials for various sensing applications in the past decades. Herein, we report a similar approach by employing the electropolymerization method to create a functional polymer layer to enhance the sensitivity of an Aluminium Organic Framework (DUT-4) for the selective detection of Chloramphenicol (CAP) antibiotic in aqueous environment. The combined strategy using the conducting polymer layer with the porous Al MOF provides surpassing electrochemical performance for sensing CAP with regard to the very low detection limit (LOD = 39 nM) and exceptionally high sensitivity (11943 μA mM-1 cm-2). In addition, the fabricated sensor exhibited good selectivity, reproducibility and stability. The developed method was successfully evaluated in various real samples including lake water and river water for CAP detection with good recovery percentages even at lower concentrations.
Collapse
Affiliation(s)
- Jithin Rafi
- Energy and Environmental Remediation Lab, Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur, Chennai, Tamilnadu, 603203, India
| | - Miriam Daniel
- Energy and Environmental Remediation Lab, Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur, Chennai, Tamilnadu, 603203, India
| | - B Neppolian
- Energy and Environmental Remediation Lab, Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur, Chennai, Tamilnadu, 603203, India.
| |
Collapse
|
3
|
Bayrak S, Gergeroglu H. Graphene-based biosensors in milk analysis: A review of recent developments. Food Chem 2024; 440:138257. [PMID: 38154279 DOI: 10.1016/j.foodchem.2023.138257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 12/04/2023] [Accepted: 12/20/2023] [Indexed: 12/30/2023]
Abstract
Cow's milk, an excellent source of fat, protein, amino acids, vitamins and minerals, is currently one of the most consumed products worldwide. Contaminations originating from diverse sources, such as biological, chemical, and physical, cause dairy product quality problems and thus dairy-related disorders, raising public health issues. For this reason, legal authorities have deemed it necessary to classify certain contaminations in commercial milk and keep them within particular limitations; therefore, it is urgent to develop next-generation detection systems that can accurately identify just the contaminants of concern to human health. This review presents a detailed investigation of biosensors based on graphene and its derivatives, which offer superior sensitivity and selectivity, by classifying the contaminants under the headings biological, chemical, and physical, in cow's milk according to their sources. We reviewed the current status of graphene-based biosensor (GBs) technology for milk or dairy analysis, highlighting its strengths and weaknesses with the help of comparative studies, tables, and charts, and we put forward a novel perspective to handle future challenges.
Collapse
Affiliation(s)
- Sule Bayrak
- Department of Food Engineering, Ege University, 35040 Izmir, Turkey.
| | - Hazal Gergeroglu
- CIC nanoGUNE, Tolosa Hiribidea 76, E-20018 Donostia - San Sebastian, Spain
| |
Collapse
|
4
|
Zain M, Ma H, Ur Rahman S, Nuruzzaman M, Chaudhary S, Azeem I, Mehmood F, Duan A, Sun C. Nanotechnology in precision agriculture: Advancing towards sustainable crop production. PLANT PHYSIOLOGY AND BIOCHEMISTRY : PPB 2024; 206:108244. [PMID: 38071802 DOI: 10.1016/j.plaphy.2023.108244] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 09/21/2023] [Accepted: 11/27/2023] [Indexed: 02/15/2024]
Abstract
Nanotechnology offers many potential solutions for sustainable agroecosystem, including improvement in nutrient use efficiency, efficacy of pest management, and minimizing the adverse environmental effects of agricultural production. Herein, we first highlighted the integrated application of nanotechnology and precision agriculture for sustainable productivity. Application of nanoparticle mediated material and advanced biosensors in precision agriculture is only possible by nanochips or nanosensors. Nanosensors offers the measurement of various stresses, soil quality parameters and detection of heavy metals along with the enhanced data collection, enabling precise decision-making and resource management in agricultural systems. Nanoencapsulation of conventional chemical fertilizers (known as nanofertilizers), and pesticides (known as nanopesticides) helps in sustained and slow release of chemicals to soils and results in precise dosage to plants. Further, nano-based disease detection kits are popular tools for early and speedy detection of viral diseases. Many other innovative approaches including biosynthesized nanoparticles have been evaluated and proposed at various scales, but in fact there are some barriers for practical application of nanotechnology in soil-plant system, including safety and regulatory concerns, efficient delivery at field levels, and consumer acceptance. Finally, we outlined the policy options and actions required for sustainable agricultural productivity, and proposed various research pathways that may help to overcome the upcoming challenges regarding practical implications of nanotechnology.
Collapse
Affiliation(s)
- Muhammad Zain
- Key Laboratory of Crop Genetics and Physiology of Jiangsu Province, Key Laboratory of Crop Cultivation and Physiology of Jiangsu Province, College of Agriculture, Yangzhou University, Yangzhou, 225009, China
| | - Haijiao Ma
- Key Laboratory of Crop Genetics and Physiology of Jiangsu Province, Key Laboratory of Crop Cultivation and Physiology of Jiangsu Province, College of Agriculture, Yangzhou University, Yangzhou, 225009, China
| | - Shafeeq Ur Rahman
- Water Science and Environmental Engineering Research Center, College of Chemical and Environmental Engineering, Shenzhen University, Shenzhen, 518060, China
| | - Md Nuruzzaman
- Faculty of Agriculture, Hajee Mohammad Danesh Science and Technology University, Dinajpur, 5200, Bangladesh
| | - Sadaf Chaudhary
- Department of Botany, University of Agriculture Faisalabad, Faisalabad, 38000, Pakistan
| | - Imran Azeem
- Beijing Key Laboratory of Farmland Soil Pollution Prevention and Remediation and College of Resources and Environmental Sciences, China Agricultural University, Beijing, 100193, China
| | - Faisal Mehmood
- Key Laboratory of Crop Water Use and Regulation, Farmland Irrigation Research Institute, Chinese Academy of Agriculture Sciences, Ministry of Agriculture and Rural Affairs, Xinxiang, 453003, China; Department of Land and Water Management, Faculty of Agricultural Engineering, Sindh Agriculture University, Tandojam, 70060, Pakistan
| | - Aiwang Duan
- Key Laboratory of Crop Water Use and Regulation, Farmland Irrigation Research Institute, Chinese Academy of Agriculture Sciences, Ministry of Agriculture and Rural Affairs, Xinxiang, 453003, China
| | - Chengming Sun
- Key Laboratory of Crop Genetics and Physiology of Jiangsu Province, Key Laboratory of Crop Cultivation and Physiology of Jiangsu Province, College of Agriculture, Yangzhou University, Yangzhou, 225009, China.
| |
Collapse
|
5
|
Meenakshi GA, Sakthinathan S, Chiu TW. Fabrication of Carbon Nanofiber Incorporated with CuWO 4 for Sensitive Electrochemical Detection of 4-Nitrotoluene in Water Samples. SENSORS (BASEL, SWITZERLAND) 2023; 23:5668. [PMID: 37420832 DOI: 10.3390/s23125668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 06/05/2023] [Accepted: 06/08/2023] [Indexed: 07/09/2023]
Abstract
In the current work, copper tungsten oxide (CuWO4) nanoparticles are incorporated with carbon nanofiber (CNF) to form CNF/CuWO4 nanocomposite through a facile hydrothermal method. The prepared CNF/CuWO4 composite was applied to the electrochemical detection of hazardous organic pollutants of 4-nitrotoluene (4-NT). The well-defined CNF/CuWO4 nanocomposite is used as a modifier of glassy carbon electrode (GCE) to form CuWO4/CNF/GCE electrode for the detection of 4-NT. The physicochemical properties of CNF, CuWO4, and CNF/CuWO4 nanocomposite were examined by various characterization techniques, such as X-ray diffraction studies, field emission scanning electron microscopy, EDX-energy dispersive X-ray microanalysis, and high-resolution transmission electron microscopy. The electrochemical detection of 4-NT was evaluated using cyclic voltammetry (CV) the differential pulse voltammetry detection technique (DPV). The aforementioned CNF, CuWO4, and CNF/CuWO4 materials have better crystallinity with porous nature. The prepared CNF/CuWO4 nanocomposite has better electrocatalytic ability compared to other materials such as CNF, and CuWO4. The CuWO4/CNF/GCE electrode exhibited remarkable sensitivity of 7.258 μA μM-1 cm-2, a low limit of detection of 86.16 nM, and a long linear range of 0.2-100 μM. The CuWO4/CNF/GCE electrode exhibited distinguished selectivity, acceptable stability of about 90%, and well reproducibility. Meanwhile, the GCE/CNF/CuWO4 electrode has been applied to real sample analysis with better recovery results of 91.51 to 97.10%.
Collapse
Affiliation(s)
- Ganesh Abinaya Meenakshi
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan
- Institute of Materials Science and Engineering, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan
| | - Subramanian Sakthinathan
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan
- Institute of Materials Science and Engineering, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan
| | - Te-Wei Chiu
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan
- Institute of Materials Science and Engineering, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan
| |
Collapse
|
6
|
Ma Q, Yang Y, Yang W, Yang L, Zhang X, Zhang M. Two colors, one-step, self-drive fluorescent strategy for chloramphenicol detection base on DNAzyme cleavage triggered hybridization chain reaction. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 292:122386. [PMID: 36739663 DOI: 10.1016/j.saa.2023.122386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 01/06/2023] [Accepted: 01/16/2023] [Indexed: 06/18/2023]
Abstract
A two colors, one-step, self-drive fluorescent strategy was developed for chloramphenicol (CAP) detection based on cyclic cleavage of molecular beacon (MB) by pincer DNA sequences. CAP can bind with its aptamer and active the enzyme-strand (E-DNA). Then the E-DNA can circularly cleave the MB on the both side of pincer DNA sequences. The cleaved fragments can self-assembly to form a long duplex and cause the great recovery of the two colors fluorescent signal. The limit of detection was as low as 0.7 pM. Importantly, the whole detection process is very simple with only one-step operation. Moreover, the two colors fluorescent signals can greatly enhance the accuracy of the result. It was also successfully used to detect CAP in actual samples.
Collapse
Affiliation(s)
- Qin Ma
- Division of Gastrointestinal Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China
| | - Yun Yang
- Colorectal Cancer Center, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China
| | - Wenming Yang
- Division of Gastrointestinal Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China
| | - Li Yang
- The Third Hospital of Mianyang/Sichuan Mental Health Center, Mianyang, Sichuan 621000, China
| | - Xin Zhang
- The Third Hospital of Mianyang/Sichuan Mental Health Center, Mianyang, Sichuan 621000, China.
| | - Mingming Zhang
- Colorectal Cancer Center, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China.
| |
Collapse
|
7
|
Lai T, Shu H, Yao B, Lai S, Chen T, Xiao X, Wang Y. A Highly Selective Electrochemical Sensor Based on Molecularly Imprinted Copolymer Functionalized with Arginine for the Detection of Chloramphenicol in Honey. BIOSENSORS 2023; 13:bios13050505. [PMID: 37232866 DOI: 10.3390/bios13050505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 04/24/2023] [Accepted: 04/24/2023] [Indexed: 05/27/2023]
Abstract
Developing an efficient method for chloramphenicol (CAP) detection is of great significance for food safety. Arginine (Arg) was selected as a functional monomer. Benefiting from its excellent electrochemical performance, which is different from traditional functional monomers, it can be combined with CAP to form a highly selective molecularly imprinted polymer (MIP) material. It overcomes the shortcoming of poor MIP sensitivity faced by traditional functional monomers, and achieves high sensitivity detection without compounding other nanomaterials, greatly reducing the preparation difficulty and cost investment of the sensor. The possible binding sites between CAP and Arg molecules were calculated by molecular electrostatic potential (MEP). A low-cost, non-modified MIP electrochemical sensor was developed for the high-performance detection of CAP. The prepared sensor has a wide linear range from 1 × 10-12 mol L-1 to 5 × 10-4 mol L-1, achieves a very low concentration CAP detection, and the detection limit is 1.36 × 10-13 mol L-1. It also exhibits excellent selectivity, anti-interference, repeatability, and reproducibility. The detection of CAP in actual honey samples was achieved, which has important practical value in food safety.
Collapse
Affiliation(s)
- Tingrun Lai
- National Center for International Research on Photoelectric and Energy Materials, School of Materials and Energy, Yunnan University, Kunming 650504, China
| | - Hui Shu
- National Center for International Research on Photoelectric and Energy Materials, School of Materials and Energy, Yunnan University, Kunming 650504, China
| | - Bo Yao
- National Center for International Research on Photoelectric and Energy Materials, School of Materials and Energy, Yunnan University, Kunming 650504, China
| | - Siying Lai
- National Center for International Research on Photoelectric and Energy Materials, School of Materials and Energy, Yunnan University, Kunming 650504, China
| | - Ting Chen
- Institute of Materials Science and Devices, School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Xuechun Xiao
- National Center for International Research on Photoelectric and Energy Materials, School of Materials and Energy, Yunnan University, Kunming 650504, China
| | - Yude Wang
- Yunnan Key Laboratory of Carbon Neutrality and Green Low-Carbon Technologies, Yunnan University, Kunming 650504, China
| |
Collapse
|
8
|
Meskher H, Ragdi T, Thakur AK, Ha S, Khelfaoui I, Sathyamurthy R, Sharshir SW, Pandey AK, Saidur R, Singh P, Sharifian Jazi F, Lynch I. A Review on CNTs-Based Electrochemical Sensors and Biosensors: Unique Properties and Potential Applications. Crit Rev Anal Chem 2023:1-24. [PMID: 36724894 DOI: 10.1080/10408347.2023.2171277] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Carbon nanotubes (CNTs), are safe, biocompatible, bioactive, and biodegradable materials, and have sparked a lot of attention due to their unique characteristics in a variety of applications, including medical and dye industries, paper manufacturing and water purification. CNTs also have a strong film-forming potential, permitting them to be widely employed in constructing sensors and biosensors. This review concentrates on the application of CNT-based nanocomposites in the production of electrochemical sensors and biosensors. It emphasizes the synthesis and optimization of CNT-based sensors for a range of applications and outlines the benefits of using CNTs for biomolecule immobilization. In addition, the use of molecularly imprinted polymer (MIP)-CNTs in the production of electrochemical sensors is also discussed. The challenges faced by the current CNTs-based sensors, along with some the future perspectives and their future opportunities, are also briefly explained in this paper.
Collapse
Affiliation(s)
- Hicham Meskher
- Division of Chemical Engineering, Kasdi-Merbah University, Ouargla, Algeria
| | - Teqwa Ragdi
- Division of Chemical Engineering, Kasdi-Merbah University, Ouargla, Algeria
| | - Amrit Kumar Thakur
- Department of Mechanical Engineering, KPR Institute of Engineering and Technology, Coimbatore, Tamil Nadu, India
| | - Sohmyung Ha
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, UAE
- Tandon School of Engineering, New York University, New York, NY, USA
| | - Issam Khelfaoui
- School of Insurance and Economics, University of International Business and Economics, Beijing, China
| | - Ravishankar Sathyamurthy
- Department of Mechanical Engineering, King Fahd University of Petroleum and Minerals, Dammam, Saudi Arabia
- Interdisciplinary Research Center for Renewable Energy and Power Systems (IRC-REPS), King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
| | - Swellam W Sharshir
- Mechanical Engineering Department, Faculty of Engineering, Kafrelsheikh University, Kafrelsheikh, Egypt
| | - A K Pandey
- Research Centre for Nano-Materials and Energy Technology (RCNMET), School of Engineering and Technology, Sunway University, Bandar Sunway, Petaling Jaya, Malaysia
- Center for Transdisciplinary Research (CFTR), Saveetha Institute of Medical and Technical Services, Saveetha University, Chennai, India
- CoE for Energy and Eco-sustainability Research, Uttaranchal University, Dehradun, Uttarakhand, India
| | - Rahman Saidur
- Research Centre for Nano-Materials and Energy Technology (RCNMET), School of Engineering and Technology, Sunway University, Bandar Sunway, Petaling Jaya, Malaysia
| | - Punit Singh
- Institute of Engineering and Technology, Department of Mechanical Engineering, GLA University Mathura, Chaumuhan, Uttar Pradesh, India
| | | | - Iseult Lynch
- School of Geography, Earth and Environmental Sciences, University of Birmingham, Birmingham, UK
| |
Collapse
|
9
|
Rafi J, Rajan A, Neppolian B. Enhanced electrocatalytic performance of Aluminium Metal-organic framework towards the detection of broad-spectrum chloramphenicol antibiotic. Electrochim Acta 2023. [DOI: 10.1016/j.electacta.2023.142079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/27/2023]
|
10
|
Banerjee R, Ghosh D, Bhaduri SN, Biswas R, Biswas P. Electrochemical Detection of Chloramphenicol Using Metal Free Ordered Mesoporous Carbon. ChemistrySelect 2023. [DOI: 10.1002/slct.202202433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Rumeli Banerjee
- Department of Chemistry Indian Institute of Engineering Science and Technology, Shibpur Howrah 711 103 West Bengal India
| | - Debojit Ghosh
- Department of Chemistry Indian Institute of Engineering Science and Technology, Shibpur Howrah 711 103 West Bengal India
| | - Samanka Narayan Bhaduri
- Department of Chemistry Indian Institute of Engineering Science and Technology, Shibpur Howrah 711 103 West Bengal India
| | - Rima Biswas
- Department of Chemistry Indian Institute of Engineering Science and Technology, Shibpur Howrah 711 103 West Bengal India
| | - Papu Biswas
- Department of Chemistry Indian Institute of Engineering Science and Technology, Shibpur Howrah 711 103 West Bengal India
| |
Collapse
|
11
|
Application of Molecularly Imprinted Electrochemical Biomimetic Sensors for Detecting Small Molecule Food Contaminants. Polymers (Basel) 2022; 15:polym15010187. [PMID: 36616536 PMCID: PMC9824611 DOI: 10.3390/polym15010187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 12/26/2022] [Accepted: 12/27/2022] [Indexed: 01/04/2023] Open
Abstract
Environmental chemical contaminants in food seriously impact human health and food safety. Successful detection methods can effectively monitor the potential risk of emerging chemical contaminants. Among them, molecularly imprinted polymers (MIPs) based on electrochemical biomimetic sensors overcome many drawbacks of conventional detection methods and offer opportunities to detect contaminants with simple equipment in an efficient, sensitive, and low-cost manner. We searched eligible papers through the Web of Science (2000-2022) and PubMed databases. Then, we introduced the sensing mechanism of MIPs, outlined the sample preparation methods, and summarized the MIP characterization and performance. The classification of electrochemistry, as well as its advantages and disadvantages, are also discussed. Furthermore, the representative application of MIP-based electrochemical biomimetic sensors for detecting small molecular chemical contaminants, such as antibiotics, pesticides, toxins, food additives, illegal additions, organic pollutants, and heavy metal ions in food, is demonstrated. Finally, the conclusions and future perspectives are summarized and discussed.
Collapse
|
12
|
Geng L, Huang J, Zhai H, Shen Z, Han J, Yu Y, Fang H, Li F, Sun X, Guo Y. Molecularly imprinted electrochemical sensor based on multi-walled carbon nanotubes for specific recognition and determination of chloramphenicol in milk. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
13
|
K J A, Reddy S, Acharya S, B L, Deepak K, Naveen CS, Harish KN, Ramakrishna S. A review on nanomaterial-based electrodes for the electrochemical detection of chloramphenicol and furazolidone antibiotics. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:3228-3249. [PMID: 35997206 DOI: 10.1039/d2ay00941b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
To grow food for people, antibiotics were used, and these antibiotics can accumulate in the human body through food metabolism, which may have remarkably harmful effects on human health and safety. Therefore, low-cost sensors are needed for the detection of antibiotic residues in food samples. Recently, nanomaterial-based electrochemical sensors such as carbon nanoparticles, graphene nanoparticles, metal oxide nanoparticles, metal nanoparticles, and metal-organic nanostructures have been successfully used as sensing materials for the detection of chloramphenicol (CP) and furazolidone (FZ) antibiotics. However, additional efforts are still needed to fabricate effective multi-functional nanomaterial-based electrodes for the preparation of portable electrochemical sensor devices. The current review focuses on a quick introduction to CP and FZ antibiotics, followed by an outline of the current electrochemical analytical methods. In addition, we have discussed in-depth different nanoparticle supports for the electrochemical detection of CP and FZ in different matrices such as food, environmental, and biological samples. Finally, a summary of the current problems and future perspectives in this area are also highlighted.
Collapse
Affiliation(s)
- Abhishek K J
- Department of Chemistry, School of Applied Science, REVA University, Bangalore, 560064, India.
| | - Sathish Reddy
- Department of Chemistry, School of Applied Science, REVA University, Bangalore, 560064, India.
| | - Shubha Acharya
- Department of Chemistry, School of Applied Science, REVA University, Bangalore, 560064, India.
| | - Lakshmi B
- Department of Chemistry, School of Applied Science, REVA University, Bangalore, 560064, India.
| | - K Deepak
- Department of Physics, School of Applied Science, REVA University, Bangalore, 560064, India
| | - C S Naveen
- Department of Physics, School of Engineering, Presidency University, Bengaluru-560064, India
| | - K N Harish
- Department of Chemistry, Dayananda Sagar College of Engineering, Shavige Malleshwara Hills, Kumaraswamy Layout, Bengaluru, 560078, India
| | - Seeram Ramakrishna
- Department of Mechanical Engineering, Center for Nanofibers and Nanotechnology, National University of Singapore, Singapore
| |
Collapse
|
14
|
Bu L, Chen X, Song Q, Jiang D, Shan X, Wang W, Chen Z. Supersensitive detection of chloramphenicol with an EIS method based on molecularly imprinted polypyrrole at UiO-66 and CDs modified electrode. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107459] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
15
|
Recent Trends in the Development of Carbon-Based Electrodes Modified with Molecularly Imprinted Polymers for Antibiotic Electroanalysis. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10070243] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Antibiotics are antibacterial agents applied in human and veterinary medicine. They are also employed to stimulate the growth of food-producing animals. Despite their benefits, the uncontrolled use of antibiotics results in serious problems, and therefore their concentration levels in different foods as well as in environmental samples were regulated. As a consequence, there is an increasing demand for the development of sensitive and selective analytical tools for antibiotic reliable and rapid detection. These requirements are accomplished by the combination of simple, cost-effective and affordable electroanalytical methods with molecularly imprinted polymers (MIPs) with high recognition specificity, based on their “lock and key” working principle, used to modify the electrode surface, which is the “heart” of any electrochemical device. This review presents a comprehensive overview of MIP-modified carbon-based electrodes developed in recent years for antibiotic detection. The MIP preparation and electrode modification procedures, along with the performance characteristics of sensors and analytical methods, as well as the applications for the antibiotics’ quantification from different matrices (pharmaceutical, biological, food and environmental samples), are discussed. The information provided by this review can inspire researchers to go deeper into the field of MIP-modified sensors and to develop efficient means for reliable antibiotic determination.
Collapse
|
16
|
Anupriya J, Rajakumaran R, Chen SM, Karthik R, Kumar JV, Shim JJ, Shafi PM, Lee JW. Raspberry-like CuWO 4 hollow spheres anchored on sulfur-doped g-C 3N 4 composite: An efficient electrocatalyst for selective electrochemical detection of antibiotic drug nitrofurazone. CHEMOSPHERE 2022; 296:133997. [PMID: 35167833 DOI: 10.1016/j.chemosphere.2022.133997] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Revised: 01/07/2022] [Accepted: 02/11/2022] [Indexed: 06/14/2023]
Abstract
We report a highly selective and sensitive electrochemical sensor for the determination of nitrofurazone (NZ) based on sulfur-doped graphitic carbon nitride with copper tungstate hollow spheres (Sg-C3N4/CuWO4). Here, a Sg-C3N4/CuWO4 composite was synthesized by a facile ultrasonic method. The physicochemical properties of the composite were characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), energy dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS). Then, the surface morphology of the composite material was investigated by field emission scanning electron microscopy (FE-SEM) and high-resolution transmission electron microscopy (HR-TEM). Moreover, the electrochemical activity of the as-synthesized composite material was initially tested using electrochemical impedance spectroscopy (EIS). The electroanalytical techniques namely cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were carried out for the electrochemical studies. The proposed sensor exhibits lower LOD and good sensitivity of about 3 nM and 1.24 μAμM-1 cm-2 to NZ detection. In addition, the Sg-C3N4/CuWO4 modified electrode showed excellent repeatability, reproducibility, long-term storage stability and excellent selectivity. The developed sensor was successfully applied for the determination of NZ in human urine and serum samples and achieved good recovery results.
Collapse
Affiliation(s)
- Jeyaraman Anupriya
- Electroanalysis and Bioelectrochemistry Lab, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1 Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan, People's Republic of China
| | - Ramachandran Rajakumaran
- Electroanalysis and Bioelectrochemistry Lab, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1 Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan, People's Republic of China
| | - Shen Ming Chen
- Electroanalysis and Bioelectrochemistry Lab, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1 Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan, People's Republic of China.
| | - Raj Karthik
- School of Chemical Engineering, Yeungnam University, Gyeongsan, Gyeongbuk, 38541, Republic of Korea.
| | - Jeyaraj Vinoth Kumar
- Advanced Nano Surface Engineering Laboratory, Department of Mechanical Engineering, Chosun University, 309, Pilmun-daero, Dong-gu, Gwangju, 61452, Republic of Korea
| | - Jae-Jin Shim
- School of Chemical Engineering, Yeungnam University, Gyeongsan, Gyeongbuk, 38541, Republic of Korea
| | - P Muhammed Shafi
- School of Chemical Engineering, Yeungnam University, Gyeongsan, Gyeongbuk, 38541, Republic of Korea
| | - Jeong-Won Lee
- Advanced Nano Surface Engineering Laboratory, Department of Mechanical Engineering, Chosun University, 309, Pilmun-daero, Dong-gu, Gwangju, 61452, Republic of Korea
| |
Collapse
|
17
|
David IG, Buleandra M, Popa DE, Cheregi MC, Iorgulescu EE. Past and Present of Electrochemical Sensors and Methods for Amphenicol Antibiotic Analysis. MICROMACHINES 2022; 13:mi13050677. [PMID: 35630144 PMCID: PMC9143398 DOI: 10.3390/mi13050677] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 04/12/2022] [Accepted: 04/24/2022] [Indexed: 12/30/2022]
Abstract
Amphenicols are broad-spectrum antibiotics. Despite their benefits, they also present toxic effects and therefore their presence in animal-derived food was regulated. Various analytical methods have been reported for their trace analysis in food and environmental samples, as well as in the quality control of pharmaceuticals. Among these methods, the electrochemical ones are simpler, more rapid and cost-effective. The working electrode is the core of any electroanalytical method because the selectivity and sensitivity of the determination depend on its surface activity. Therefore, this review offers a comprehensive overview of the electrochemical sensors and methods along with their performance characteristics for chloramphenicol, thiamphenicol and florfenicol detection, with a focus on those reported in the last five years. Electrode modification procedures and analytical applications of the recently described devices for amphenicol electroanalysis in various matrices (pharmaceuticals, environmental, foods), together with the sample preparation methods were discussed. Therefore, the information and the concepts contained in this review can be a starting point for future new findings in the field of amphenicol electrochemical detection.
Collapse
|
18
|
Electrochemical determination of nitroaromatic explosives using glassy carbon/multi walled carbon nanotube/polyethyleneimine electrode coated with gold nanoparticles. Talanta 2022; 238:122990. [PMID: 34857323 DOI: 10.1016/j.talanta.2021.122990] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 10/20/2021] [Indexed: 02/04/2023]
Abstract
The on site/in field detection of explosives has become a rising priority for homeland security and counter-terrorism measures. This work presents the sensitive detection of nitroaromatic explosives using glassy carbon/multi-walled carbon nanotubes/polyethyleneimine (GC/MWCNTs/PEI) electrode coated with gold nanoparticles (AuNPs). MWCNTs and PEI could be well dispersed in ethanol/water solution, giving rise to a thin and homogeneous film on GCE. The GC/MWCNTs/PEI electrode was electrochemically modified with AuNPs and used for the differential pulse voltammetric (DPV) detection of nitroaromatics. The enhanced detection sensitivities were achieved through π-π and charge-transfer (CT) interactions between the electron-deficient nitroaromatic explosives and donor amine groups in PEI to which gold nanoparticles were linked, providing increased analyte affinity toward the modified GCE. Calibration curves of current intensity versus concentration were linear in the range of 0.05-8 mg L-1 for TNT, 0.2-4 mg L-1 for 2,4-dinitrotoluene (DNT), 1-20 mg L-1 for 2,4-dinitrophenol (2,4-DNP), 0.25-10 mg L-1 for picric acid (PA), and 0.05-4 mg L-1 for 2,4,6-trinitrophenyl-N-methylnitramine (tetryl) with detection limits (LOD) of 15 μg L-1, 45 μg L-1, 135 μg L-1, 30 μg L-1, and 12 μg L-1, respectively. The proposed method was successfully applied to the analysis of nitroaromatics in synthetic explosive mixtures and military composite explosives (comp B and octol). The electrochemical method was not affected by possible interferents of electroactive camouflage materials and common soil ions. Method validation was performed against the reference LC-MS method on TNT and PA-contaminated clay soil samples separately.
Collapse
|
19
|
Gopi PK, Srinithi S, Chen SM, Hunsur Ravikumar C. Simple construction of GdBiVO4 assembled on reduced graphene oxide for selective and sensitive electrochemical detection of chloramphenicol in food samples. NEW J CHEM 2022. [DOI: 10.1039/d1nj04457e] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
In the present study, the influence of phase purity and crystallinity on the electrochemical properties of well-designed GdBiVO4@rGO nanocomposite, fabricated by the facile hydrothermal method for the detection of chloramphenicol (CP), is reported.
Collapse
Affiliation(s)
- Praveen Kumar Gopi
- Electroanalysis and Bioelectrochemistry Lab, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan, Republic of China
| | - Subburaj Srinithi
- Electroanalysis and Bioelectrochemistry Lab, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan, Republic of China
| | - Shen-Ming Chen
- Electroanalysis and Bioelectrochemistry Lab, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan, Republic of China
| | - Chandan Hunsur Ravikumar
- Centre for Nano and Materials Sciences, Jain global campus, Jain University, Jakkasandra post Ramanagaram dist., India, 52110
| |
Collapse
|
20
|
Pakapongpan S, Poo-Arporn Y, Tuantranont A, Poo-Arporn RP. A facile one-pot synthesis of magnetic iron oxide nanoparticles embed N-doped graphene modified magnetic screen printed electrode for electrochemical sensing of chloramphenicol and diethylstilbestrol. Talanta 2022; 241:123184. [PMID: 35032900 DOI: 10.1016/j.talanta.2021.123184] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 12/21/2021] [Accepted: 12/26/2021] [Indexed: 10/19/2022]
Abstract
Trace determination of antibacterial agents is crucial to minimize risks of human intoxication and in the prevention of serious environmental impacts. Herein, a simple one-pot solvothermal synthesis approach for a magnetic iron oxide embed nitrogen-doped graphene (MIO@NG) nanohybrid was fabricated without the addition of any extra reductant and its application towards ultrasensitive chloramphenicol (CAP) and diethylstilbestrol (DES) electrochemical sensor is demonstrated to screen for antibiotic residue contamination in milk samples. The prepared nanohybrid was modified on a magnetic screen-printed electrode (MSPE) to make it portable for on-site detection. The determination of two additive drugs, CAP and DES, was achieved based on the reduction current response at MIO@NG modified MSPE (MIO@NG/MSPE) to eliminate interference as far as possible. Uniform dispersed MIO nanoparticles are grown in situ on the surface of nitrogen-doped graphene sheets. The morphology of MIO@NG was confirmed by transmission electron microscopy (TEM) analysis. The chemical structure of the prepared MIO@NG was characterized by x-ray diffraction (XRD), x-ray photoemission spectroscopy (XPS), Raman spectroscopy, and extended x-ray absorption fine structure (EXAFS). Moreover, the superparamagnism property was investigated by vibrating sample magnetometry (VSM). The electrochemical properties of MIO@NG were evaluated with cyclic voltammetry (CV) and square wave voltammetry (SWV). Sensor performance was evaluated by testing the electrochemical activity of CAP and DES in the presence of interferences. The MIO@NG modified electrode presented superior electrochemical performance, including high sensitivity, high catalytic activity, ultimate sensitivity, very fast detection, selectivity, and excellent performance. The MIO@NG modified electrode demonstrated a detection limit of 10 nM for the detection of CAP and 6.5 nM for DES with satisfactory recovery in real samples.
Collapse
Affiliation(s)
- Saithip Pakapongpan
- Graphene and Printed Electronics for Dual-Use Applications Research Division, Nation Security and Dual-Use Technology Center, National Science and Technology Development Agency (NSTDA), Pathum Thani, 12120, Thailand.
| | - Yingyot Poo-Arporn
- Synchrotron Light Research Institute, 111 University Avenue, Nakhon Ratchasima, 30000, Thailand
| | - Adisorn Tuantranont
- Graphene and Printed Electronics for Dual-Use Applications Research Division, Nation Security and Dual-Use Technology Center, National Science and Technology Development Agency (NSTDA), Pathum Thani, 12120, Thailand
| | - Rungtiva P Poo-Arporn
- Biological Engineering Program, Faculty of Engineering, King Mongkut's University of Technology, Thonburi, Bangkok, 10140, Thailand.
| |
Collapse
|
21
|
Zhu J, Huang X, Song W. Physical and Chemical Sensors on the Basis of Laser-Induced Graphene: Mechanisms, Applications, and Perspectives. ACS NANO 2021; 15:18708-18741. [PMID: 34881870 DOI: 10.1021/acsnano.1c05806] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Laser-induced graphene (LIG) is produced rapidly by directly irradiating carbonaceous precursors, and it naturally exhibits as a three-dimensional porous structure. Due to advantages such as simple preparation, time-saving, environmental friendliness, low cost, and expanding categories of raw materials, LIG and its derivatives have achieved broad applications in sensors. This has been witnessed in various fields such as wearable devices, disease diagnosis, intelligent robots, and pollution detection. However, despite LIG sensors having demonstrated an excellent capability to monitor physical and chemical parameters, the systematic review of synthesis, sensing mechanisms, and applications of them combined with comparison against other preparation approaches of graphene is still lacking. Here, graphene-based sensors for physical, biological, and chemical detection are reviewed first, followed by the introduction of general preparation methods for the laser-induced method to yield graphene. The preparation and advantages of LIG, sensing mechanisms, and the properties of different types of emerging LIG-based sensors are comprehensively reviewed. Finally, possible solutions to the problems and challenges of preparing LIG and LIG-based sensors are proposed. This review may serve as a detailed reference to guide the development of LIG-based sensors that possess properties for future smart sensors in health care, environmental protection, and industrial production.
Collapse
Affiliation(s)
- Junbo Zhu
- Department of Chemistry, Capital Normal University, Beijing 100048, China
- Beijing Key Laboratory for Optical Materials and Photonic Devices, Beijing 100048, China
| | - Xian Huang
- Department of Biomedical Engineering, Tianjin University, Tianjin 300072, China
| | - Weixing Song
- Department of Chemistry, Capital Normal University, Beijing 100048, China
- Beijing Key Laboratory for Optical Materials and Photonic Devices, Beijing 100048, China
| |
Collapse
|
22
|
Vinícius de Faria L, Lisboa TP, Alves GF, Costa Matos MA, Abarza Muñoz RA, Matos RC. Adsorptive stripping voltammetric determination of chloramphenicol residues in milk samples using reduced graphene oxide sensor. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:5711-5718. [PMID: 34812438 DOI: 10.1039/d1ay01756j] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In this paper, the electrochemical response of chloramphenicol (CHL) was investigated on a bare glassy carbon electrode (GCE) and after modification with reduced graphene oxide (GCE/rGO). Preliminary studies by cyclic voltammetry demonstrated an adsorption-controlled mass transport regime of CHL species and a pH-dependent behavior on both electrode surfaces. An adsorptive stripping differential pulse voltammetry (AdSDPV) method was proposed and under optimized instrumental conditions, a comparison of the analytical characteristics of both sensors was performed. The GCE/rGO sensor showed an increase in sensitivity (10-fold), and an anticipation of the reduction potential (200 mV), compared to the bare electrode, due to the adsorptive character (pre-concentration of the CHL species) and the electrocatalytic effect of the nanomaterial. The method was applied to skimmed and whole milk samples, which were simply diluted (50-fold) in supporting electrolyte. The results by AdSDPV using GCE/rGO showed adequate detectability (0.22 μmol L-1), good precision with a 6% relative standard deviation (RSD) and satisfactory recovery ranging from 93 to 108%. The obtained results were statistically similar (95% confidence level) with those performed through ultra-fast liquid chromatography (UFLC). Furthermore, the sensor showed an improvement in the analytical performance for CHL detection, when compared to other sensors reported in the literature. Therefore, the developed method is reliable and promising for implementation in monitoring CHL residues in milk samples.
Collapse
Affiliation(s)
- Lucas Vinícius de Faria
- NUPIS (Núcleo de Pesquisa em Instrumentação e Separações Analíticas), Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36036-900, Brazil.
| | - Thalles Pedrosa Lisboa
- NUPIS (Núcleo de Pesquisa em Instrumentação e Separações Analíticas), Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36036-900, Brazil.
| | - Guilherme Figueira Alves
- NUPIS (Núcleo de Pesquisa em Instrumentação e Separações Analíticas), Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36036-900, Brazil.
| | - Maria Auxiliadora Costa Matos
- NUPIS (Núcleo de Pesquisa em Instrumentação e Separações Analíticas), Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36036-900, Brazil.
| | | | - Renato Camargo Matos
- NUPIS (Núcleo de Pesquisa em Instrumentação e Separações Analíticas), Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, 36036-900, Brazil.
| |
Collapse
|
23
|
Jia BJ, Lin M, Wang JP, Wu NP. Synthesis of molecularly imprinted microspheres and development of a fluorescence method for detection of chloramphenicol in meat. LUMINESCENCE 2021; 36:1767-1774. [PMID: 34270836 DOI: 10.1002/bio.4121] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 07/10/2021] [Accepted: 07/13/2021] [Indexed: 12/27/2022]
Abstract
In this study, nitrobenzene was used as dummy template to synthesize a type of specific molecularly imprinted microspheres for chloramphenicol, and 4-nitroaniline was coupled with three fluorophores to synthesize three fluorescent tracers. Then a competitive fluorescence method was developed on a conventional microplate for detection of chloramphenicol in chicken and pork samples. This method contained only one sample-loading step, so one assay was finished within 30 min. The IC50 was 1.8 ng/ml, and the limit of detection was 0.06 ng/g. The recoveries from chloramphenicol-fortified blank meat samples were in the range 67.5-96.2%. Furthermore, this method could be recycled three times. The detection results for some real meat samples were identical to that of a LC-MS/MS method. Therefore, this method could be used as a practical tool for routine screening for the residue of chloramphenicol in large number of meat samples.
Collapse
Affiliation(s)
- Bing Jie Jia
- College of Veterinary Medicine, Hebei Agricultural University, Baoding, Hebei, China
| | - Min Lin
- College of Veterinary Medicine, Hebei Agricultural University, Baoding, Hebei, China
| | - Jian Ping Wang
- College of Veterinary Medicine, Hebei Agricultural University, Baoding, Hebei, China
| | - Ning Peng Wu
- Henan Institute of Veterinary Drug and Feed Control, Zhengzhou, Henan, China
| |
Collapse
|
24
|
Lakard S, Pavel IA, Lakard B. Electrochemical Biosensing of Dopamine Neurotransmitter: A Review. BIOSENSORS 2021; 11:179. [PMID: 34204902 PMCID: PMC8229248 DOI: 10.3390/bios11060179] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 05/31/2021] [Accepted: 06/01/2021] [Indexed: 12/17/2022]
Abstract
Neurotransmitters are biochemical molecules that transmit a signal from a neuron across the synapse to a target cell, thus being essential to the function of the central and peripheral nervous system. Dopamine is one of the most important catecholamine neurotransmitters since it is involved in many functions of the human central nervous system, including motor control, reward, or reinforcement. It is of utmost importance to quantify the amount of dopamine since abnormal levels can cause a variety of medical and behavioral problems. For instance, Parkinson's disease is partially caused by the death of dopamine-secreting neurons. To date, various methods have been developed to measure dopamine levels, and electrochemical biosensing seems to be the most viable due to its robustness, selectivity, sensitivity, and the possibility to achieve real-time measurements. Even if the electrochemical detection is not facile due to the presence of electroactive interfering species with similar redox potentials in real biological samples, numerous strategies have been employed to resolve this issue. The objective of this paper is to review the materials (metals and metal oxides, carbon materials, polymers) that are frequently used for the electrochemical biosensing of dopamine and point out their respective advantages and drawbacks. Different types of dopamine biosensors, including (micro)electrodes, biosensing platforms, or field-effect transistors, are also described.
Collapse
Affiliation(s)
| | | | - Boris Lakard
- Institut UTINAM, UMR CNRS 6213, University of Bourgogne Franche-Comté, 16 Route de Gray, 25030 Besançon, France; (S.L.); (I.-A.P.)
| |
Collapse
|
25
|
He L, Huang R, Xiao P, Liu Y, Jin L, Liu H, Li S, Deng Y, Chen Z, Li Z, He N. Current signal amplification strategies in aptamer-based electrochemical biosensor: A review. CHINESE CHEM LETT 2021. [DOI: 10.1016/j.cclet.2020.12.054] [Citation(s) in RCA: 51] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
26
|
Xia Y, Ou X, Zhao Y, Xia M, Chen D, Gao W. Facile Synthesis of Reduced Graphene Oxide‐octahedral Mn
3
O
4
Nanocomposites as a Platform for the Electrochemical Determination of Metronidazole and Sulfamonomethoxine. ELECTROANAL 2021. [DOI: 10.1002/elan.202100015] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Ya‐Mu Xia
- State Key Laboratory Base of Eco-chemical Engineering College of Chemical Engineering Qingdao University of Science and Technology Qingdao 266042 People's Republic of China
| | - Xiang Ou
- State Key Laboratory Base of Eco-chemical Engineering College of Chemical Engineering Qingdao University of Science and Technology Qingdao 266042 People's Republic of China
| | - Yan Zhao
- State Key Laboratory Base of Eco-chemical Engineering College of Chemical Engineering Qingdao University of Science and Technology Qingdao 266042 People's Republic of China
| | - Meng Xia
- State Key Laboratory Base of Eco-chemical Engineering College of Chemical Engineering Qingdao University of Science and Technology Qingdao 266042 People's Republic of China
| | - Dong Chen
- State Key Laboratory Base of Eco-chemical Engineering College of Chemical Engineering Qingdao University of Science and Technology Qingdao 266042 People's Republic of China
| | - Wei‐Wei Gao
- State Key Laboratory Base of Eco-chemical Engineering College of Chemical Engineering Qingdao University of Science and Technology Qingdao 266042 People's Republic of China
| |
Collapse
|
27
|
Zhu Y, Li X, Xu Y, Wu L, Yu A, Lai G, Wei Q, Chi H, Jiang N, Fu L, Ye C, Lin CT. Intertwined Carbon Nanotubes and Ag Nanowires Constructed by Simple Solution Blending as Sensitive and Stable Chloramphenicol Sensors. SENSORS (BASEL, SWITZERLAND) 2021; 21:1220. [PMID: 33572293 PMCID: PMC7915990 DOI: 10.3390/s21041220] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Revised: 02/02/2021] [Accepted: 02/04/2021] [Indexed: 11/17/2022]
Abstract
Chloramphenicol (CAP) is a harmful compound associated with human hematopathy and neuritis, which was widely used as a broad-spectrum antibacterial agent in agriculture and aquaculture. Therefore, it is significant to detect CAP in aquatic environments. In this work, carbon nanotubes/silver nanowires (CNTs/AgNWs) composite electrodes were fabricated as the CAP sensor. Distinguished from in situ growing or chemical bonding noble metal nanomaterials on carbon, this CNTs/AgNWs composite was formed by simple solution blending. It was demonstrated that CNTs and AgNWs both contributed to the redox reaction of CAP in dynamics, and AgNWs was beneficial in thermodynamics as well. The proposed electrochemical sensor displayed a low detection limit of up to 0.08 μM and broad linear range of 0.1-100 μM for CAP. In addition, the CNTs/AgNWs electrodes exhibited good performance characteristics of repeatability and reproducibility, and proved suitable for CAP analysis in real water samples.
Collapse
Affiliation(s)
- Yangguang Zhu
- Laboratory of Environmental Biotechnology, School of Environmental and Civil Engineering, Jiangnan University, Wuxi 214122, China;
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China;
| | - Xiufen Li
- Laboratory of Environmental Biotechnology, School of Environmental and Civil Engineering, Jiangnan University, Wuxi 214122, China;
| | - Yuting Xu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (Y.X.); (L.F.)
| | - Lidong Wu
- Key Laboratory of Control of Quality and Safety for Aquatic Products, Chinese Academy of Fishery Sciences, Beijing 100141, China;
| | - Aimin Yu
- Department of Chemistry and Biotechnology, Faculty of Science, Engineering and Technology, Swinburne University of Technology, Hawthorn, VIC 3122, Australia;
| | - Guosong Lai
- Department of Chemistry, Hubei Normal University, Huangshi 435002, China;
| | - Qiuping Wei
- School of Materials Science and Engineering, Central South University, Changsha 410083, China;
| | - Hai Chi
- East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, China;
| | - Nan Jiang
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China;
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Li Fu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China; (Y.X.); (L.F.)
| | - Chen Ye
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China;
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Cheng-Te Lin
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China;
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
28
|
Amiripour F, Ghasemi S, Azizi SN. Design of turn-on luminescent sensor based on nanostructured molecularly imprinted polymer-coated zirconium metal-organic framework for selective detection of chloramphenicol residues in milk and honey. Food Chem 2021; 347:129034. [PMID: 33486363 DOI: 10.1016/j.foodchem.2021.129034] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 01/02/2021] [Accepted: 01/04/2021] [Indexed: 01/13/2023]
Abstract
Herein, an optical sensor based on nanostructured molecularly imprinted polymer (MIP) coated on a luminescent zirconium metal-organic framework (MIP/Zr-LMOF) is introduced, and its performance is investigated for the fluorescent determination of chloramphenicol (CAP) antibiotic residues in milk and honey. To fabricate the sensor, the surface of Zr-LMOF is modified with MIP in the presence of CAP template, resulting in the introduction of recognition sites for antibiotic molecules. The porous structure of Zr-LMOF with specific binding sites for CAP recognition benefiting from coated MIP leads to selective and sensitive detection of antibiotic. The probe yields a linear range for detection of CAP in trace concentrations (0.16-161.56 µg.L-1) and provides a detection limit of 0.013 µg.L-1. Acceptable recoveries are achieved for antibiotic in real samples, which are consistent with that obtained from liquid chromatography-tandem mass spectrometry (LC-MS/MS), confirm the favorable performance of sensor for accurate determination of CAP in practical applications.
Collapse
Affiliation(s)
- Fatemeh Amiripour
- Analytical Division, Faculty of Chemistry, University of Mazandaran, 47416-95447 Babolsar, Iran
| | - Shahram Ghasemi
- Faculty of Chemistry, University of Mazandaran, Babolsar, Iran.
| | - Seyed Naser Azizi
- Analytical Division, Faculty of Chemistry, University of Mazandaran, 47416-95447 Babolsar, Iran
| |
Collapse
|
29
|
A highly selective electrochemical sensor based on surface molecularly imprinted copolymer for the detection of 5-hydroxytryptamine. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105748] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
30
|
Feroz M, Vadgama P. Molecular Imprinted Polymer Modified Electrochemical Sensors for Small Drug Analysis: Progress to Practical Application. ELECTROANAL 2020. [DOI: 10.1002/elan.202060276] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Momina Feroz
- Institute of Chemistry University of the Punjab 54590 Lahore Pakistan
| | - Pankaj Vadgama
- School of Engineering and Materials Science Queen Mary University of London Mile End Road London E1 4NS United Kingdom
| |
Collapse
|
31
|
Benachio I, Lobato A, Gonçalves LM. Employing molecularly imprinted polymers in the development of electroanalytical methodologies for antibiotic determination. J Mol Recognit 2020; 34:e2878. [PMID: 33022110 DOI: 10.1002/jmr.2878] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2020] [Revised: 09/11/2020] [Accepted: 09/21/2020] [Indexed: 12/25/2022]
Abstract
Antibiotics, although being amazing compounds, need to be monitored in the environment and foodstuff. This is primarily to prevent the development of antibiotic resistance that may make them ineffective. Unsurprisingly, advances in analyticalsciences that can improve their determination are appreciated. Electrochemical techniques are known for their simplicity, sensitivity, portability and low-cost; however, they are often not selective enough without recurring to a discriminating element like an antibody. Molecular imprinting technology aims to create artificial tissues mimicking antibodies named molecularly imprinted polymers (MIPs), these retain the advantages of selectivity but without the typical disadvantages of biological material, like limited shelf-life and high cost. This manuscript aims to review all analytical methodologies for antibiotics, using MIPs, where the detection technique is electrochemical, like differential pulse voltammetry (DPV), square-wave voltammetry (SWV) or electrochemical impedance spectroscopy (EIS). MIPs developed by electropolymerization (e-MIPs) were applied in about 60 publications and patents found in the bibliographic search, while MIPs developed by other polymerization techniques, like temperature assisted ("bulk") or photopolymerization, were limited to around 40. Published works covered the electroanalysis of a wide range of different antibiotics (β-lactams, tetracyclines, quinolones, macrolides, aminoglycosides, among other), in a wide range of matrices (food, environmental and biological).
Collapse
Affiliation(s)
- Ingrid Benachio
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo (USP), São Paulo, Brazil
| | - Alnilan Lobato
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo (USP), São Paulo, Brazil
| | - Luís Moreira Gonçalves
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo (USP), São Paulo, Brazil
| |
Collapse
|
32
|
Sun J, Chen C, Zhang Y, Sun X. A novel fluorescent molecularly imprinted polymer SiO 2 @CdTe QDs@MIP for paraquat detection and adsorption. LUMINESCENCE 2020; 36:345-352. [PMID: 32945114 DOI: 10.1002/bio.3949] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 08/22/2020] [Accepted: 09/07/2020] [Indexed: 01/13/2023]
Abstract
Paraquat (PQ) residue is harmful for human health, agriculture, and the aquatic environment. This paper proposes a novel fluorescent molecularly imprinted polymer (MIP), SiO2 @CdTe QDs@MIP, for PQ detection and adsorption. The MIP was synthesized using 3-aminopropyltriethoxysilane as the functional monomer, 4,4'-bipyridyl as the template molecule, and tetraethoxysilane as the cross-linker. In addition, CdTe quantum dots featuring unique optical characteristics and excellent photochemical stability were combined as signal reporter. The synthesized MIP had a Brunauer-Emmett-Teller surface area of 68.2 m2 /g, pore volume of 0.42 cm3 /g and pore size of 6.9 nm, demonstrating the potential for both PQ detection and adsorption. For PQ detection, the MIP could achieve three orders of magnitude better than the limit of detection, and one order of magnitude wider detection range than existing methods. The PQ recovery values for real samples of water and corn were 96.4-102.1% and 93.9-97.3%, respectively. The amount of PQ detected by the MIP was within 98.05% on average of that using high-performance liquid chromatography. For PQ adsorption, the MIP had an adsorption capacity of 3.36 mg/g, and followed a pseudo-second-order kinetic model with excellent toxicological characteristics. Overall, the novel SiO2 @CdTe QDs@MIP proposed in this paper could facilitate an efficient and convenient method for PQ detection and adsorption.
Collapse
Affiliation(s)
- Jiadi Sun
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, Jiangsu, China.,State Key Laboratory of Dairy Biotechnology, Shanghai Engineering Research Center of Dairy Biotechnology, Dairy Research Institute, Bright Dairy & Food Co., Ltd, Shanghai, China
| | - Chen Chen
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, Jiangsu, China
| | - Yinzhi Zhang
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, Jiangsu, China
| | - Xiulan Sun
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, Jiangsu, China
| |
Collapse
|
33
|
Microchip capillary electrophoresis dairy device using fluorescence spectroscopy for detection of ciprofloxacin in milk samples. Sci Rep 2020; 10:13548. [PMID: 32782384 PMCID: PMC7419520 DOI: 10.1038/s41598-020-70566-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2020] [Accepted: 07/24/2020] [Indexed: 11/09/2022] Open
Abstract
Detecting antibiotics in the milk supply chain is crucial to protect humans from allergic reactions, as well as preventing the build-up of antibiotic resistance. The dairy industry has controls in place at processing facilities, but controls on dairy farms are limited to manual devices. Errors in the use of these manual devices can result in severe financial harm to the farms. This illustrates an urgent need for automated methods of detecting antibiotics on a dairy farm, to prevent the shipment of milk containing antibiotics. This work introduces the microchip capillary electrophoresis dairy device, a low-cost system that utilizes microchip capillary electrophoresis as well as fluorescence spectroscopy for the detection of ciprofloxacin contained in milk. The microchip capillary electrophoresis dairy device is operated under antibiotic-absent conditions, with ciprofloxacin not present in a milk sample, and antibiotic-present conditions, with ciprofloxacin present in a milk sample. The response curve for the microchip capillary electrophoresis dairy device is found through experimental operation with varied concentrations of ciprofloxacin. The sensitivity and limit of detection are quantified for the microchip capillary electrophoresis dairy device.
Collapse
|
34
|
Yu W, Tang Y, Sang Y, Liu W, Wang S, Wang X. Preparation of a carboxylated single-walled carbon-nanotube-chitosan functional layer and its application to a molecularly imprinted electrochemical sensor to quantify semicarbazide. Food Chem 2020; 333:127524. [PMID: 32679418 DOI: 10.1016/j.foodchem.2020.127524] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 06/21/2020] [Accepted: 07/05/2020] [Indexed: 12/26/2022]
Abstract
Semicarbazide (SEM) is a protein-bound nitrofurazone metabolite that is detrimental to human health. Therefore, to ensure food safety, it is necessary to detect SEM in food samples. To this end, we developed a novel electrochemical sensor to detect SEM by using a molecularly imprinted polymer (MIP) as the recognition element. Computer-aided molecular modelling was performed to guide the synthesis of the MIP, and subsequently, MIP/carboxylated single-walled carbon-nanotubes/chitosan (MIP/SWNTs-COOH/CS) was prepared as the sensing platform to develop the electrochemical sensor. The linear range of the sensor was 0.04-7.6 ng mL-1, with a detection limit of 0.025 ng mL-1. The sensor was successfully applied to detect SEM in four different real samples, with recoveries ranging from 83.16% to 93.40%. The results indicated that the fabricated electrochemical sensor can be widely applied to detect SEM in the environment and in agri-food products.
Collapse
Affiliation(s)
- Wenlong Yu
- College of Food Science and Technology, Hebei Agricultural University, Baoding, PR China
| | - Yiwei Tang
- College of Food Science and Technology, Hebei Agricultural University, Baoding, PR China
| | - Yaxin Sang
- College of Food Science and Technology, Hebei Agricultural University, Baoding, PR China
| | - Weihua Liu
- College of Food Science and Technology, Hebei Agricultural University, Baoding, PR China
| | - Shuo Wang
- College of Food Science and Technology, Hebei Agricultural University, Baoding, PR China; Medical College, Nankai University, Tianjin, PR China
| | - Xianghong Wang
- College of Food Science and Technology, Hebei Agricultural University, Baoding, PR China; Beijing Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University (BTBU), PR China.
| |
Collapse
|
35
|
An electrochemiluminescence aptamer sensor for chloramphenicol based on GO-QDs nanocomposites and enzyme-linked aptamers. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.113870] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
36
|
Li H, Wang S, Cui F, Zhuo B, Wang S, Zhao C, Liu W. Sensitive and selective detection of puerarin based on the hybrid of reduced graphene oxide and molecularly imprinted polymer. J Pharm Biomed Anal 2020; 185:113221. [PMID: 32145538 DOI: 10.1016/j.jpba.2020.113221] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2019] [Revised: 02/22/2020] [Accepted: 02/29/2020] [Indexed: 01/19/2023]
Abstract
Puerarin, an important isoflavone, has been widely used for the treatment of angina and hypertension. In this work, we developed a novel electrochemical sensor for the detection of puerarin based on the hybrid of reduced graphene oxide (RGO) and molecularly imprinted polymer (MIP). The RGO/MIP sensor functions by target puerarin recognition and electro-oxidization via a two-proton and two-electron process, enabling the detection of puerarin with good selectivity and high sensitivity. The MIP layer was integrated on the surface of RGO by the electro-co-polymerization of o-phenylenediamine (monomer) and puerarin (template), resulting in high surface area, binding capacity, good conductivity and faster mass transfer. The nanostructure of the RGO/MIP hybrid was demonstrated using scanning electron microscopy (SEM) and atomic force microscopy (AFM). Experimental conditions involved in the sensor fabrication process were evaluated. Under the optimized condition, a wide linear range (0.02 μM ∼ 40 μM) and a low detection limit (0.006 μM) were achieved. The sensor was applied to detect puerarin in human urine and injection samples, and the result was comparable with that of the gold standard method of high-performance liquid chromatography (HPLC), indicating a promise in the further application to pharmacokinetics or therapeutic drug monitoring.
Collapse
Affiliation(s)
- Haifeng Li
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, 110016, PR China
| | - Shuang Wang
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, 110016, PR China
| | - Fan Cui
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, 110016, PR China
| | - Beibei Zhuo
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, 110016, PR China
| | - Shuang Wang
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, 110016, PR China
| | - Chenrui Zhao
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, 110016, PR China
| | - Weilu Liu
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, 110016, PR China.
| |
Collapse
|
37
|
Design of heterostructured hybrids comprising ultrathin 2D bismuth tungstate nanosheets reinforced by chloramphenicol imprinted polymers used as biomimetic interfaces for mass-sensitive detection. Colloids Surf B Biointerfaces 2020; 188:110775. [PMID: 31958619 DOI: 10.1016/j.colsurfb.2020.110775] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Revised: 12/02/2019] [Accepted: 01/04/2020] [Indexed: 01/18/2023]
Abstract
Combining nanomaterials in varying morphology and functionalities gives rise to a new class of composite materials leading to innovative applications. In this study, we designed a heterostructured hybrid material consisting of two-dimensional bismuth nanosheets augmented by molecularly imprinted networks. Antibiotic overuse is now one of the main concerns in health management, and their monitoring is highly desirable but challenging. So, for this purpose, the resulting composite interface was used as a transducer for quartz crystal microbalances. The main objective was to develop highly selective mass-sensitive sensor for chloramphenicol. Morphological investigation revealed the presence of ultrathin, square shaped nanosheets, 2-3 nm in height and further supplemented by imprinted polymers. Sensor responses are described as the decrease in the frequency of microbalances owing to chloramphenicol re-binding in the templated cavities, yielding a detection limit down to 0.74 μM. This sensor demonstrated a 100 % specific detection of chloramphenicol over its interfering and structural analogs (clindamycin, thiamphenicol, and florfenicol). This composite interface offers the advantage of selective binding and excellent sensitivity due to special heterostructured morphology, in addition to benefits of robustness and online monitoring. The results suggest that such composite-based sensors can be favorable platforms, especially for commercial prospects, to obtain selective detection of other biomolecules of clinical importance.
Collapse
|
38
|
Analytical Detection of Pesticides, Pollutants, and Pharmaceutical Waste in the Environment. ENVIRONMENTAL CHEMISTRY FOR A SUSTAINABLE WORLD 2020. [DOI: 10.1007/978-3-030-38101-1_3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
39
|
Roushani M, Rahmati Z, Farokhi S, Hoseini SJ, Fath RH. The development of an electrochemical nanoaptasensor to sensing chloramphenicol using a nanocomposite consisting of graphene oxide functionalized with (3-Aminopropyl) triethoxysilane and silver nanoparticles. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 108:110388. [PMID: 31923985 DOI: 10.1016/j.msec.2019.110388] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 10/21/2019] [Accepted: 10/31/2019] [Indexed: 11/17/2022]
Abstract
In the present research, a nanoaptasensor is proposed for electrochemical measurement of chloramphenicol (CAP). To this purpose, the nanocomposite prepared from graphene oxide and functionalized with (3-Aminopropyl) triethoxysilane/silver nanoparticles to the abbreviated AgNPs/[NH2-Si]-f-GO, was utilized to modify the glassy carbon electrode (GCE). Furthermore, the modified electrode was also investigated using the electrochemical methods such as electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The AgNPs/[NH2-Si]-f-GO nanocomposite was investigated by UV-Vis spectrophotometry. Fourier transform infrared (FT-IR) spectrometry and transmission electron microscopy (TEM). Moreover, [Fe(CN)6]3-/4 solution in the role of an electrochemical probe was applied. The AgNPs/[NH2-Si]-f-GO nanocomposite was confirmed as a good layer to covalent immobilization of aptamer (Apt) onto the GCE surface. In this sense, the DPV was used as a sensitive electrochemical technique for the measurement of CAP with an appropriate linear concentration range which was found to be between 10 pM and 0.2 μM and, with a low limit of detection, it equaled 3.3 pM. CAP which was identified in the presence of other usual antibiotics existed in the real samples.
Collapse
Affiliation(s)
- Mahmoud Roushani
- Department of Chemistry, Faculty of Sciences, University of Ilam, Ilam, P. O. BOX. 69315-516, Iran.
| | - Zeinab Rahmati
- Department of Chemistry, Faculty of Sciences, University of Ilam, Ilam, P. O. BOX. 69315-516, Iran
| | - Somayeh Farokhi
- Department of Chemistry, Faculty of Sciences, University of Ilam, Ilam, P. O. BOX. 69315-516, Iran
| | - S Jafar Hoseini
- Professor Rashidi Laboratory of Organometallic Chemistry, Department of Chemistry, College of Sciences, University of Shiraz, Shiraz, P. O. BOX. 7194684795, Iran
| | - Roghayeh Hashemi Fath
- Department of Chemistry, Faculty of Sciences, University of Yasouj, Yasouj, P. O. BOX. 7591874831, Iran
| |
Collapse
|
40
|
Pan M, Yin Z, Liu K, Du X, Liu H, Wang S. Carbon-Based Nanomaterials in Sensors for Food Safety. NANOMATERIALS 2019; 9:nano9091330. [PMID: 31533228 PMCID: PMC6781043 DOI: 10.3390/nano9091330] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Revised: 09/04/2019] [Accepted: 09/10/2019] [Indexed: 12/12/2022]
Abstract
Food safety is one of the most important and widespread research topics worldwide. The development of relevant analytical methods or devices for detection of unsafe factors in foods is necessary to ensure food safety and an important aspect of the studies of food safety. In recent years, developing high-performance sensors used for food safety analysis has made remarkable progress. The combination of carbon-based nanomaterials with excellent properties is a specific type of sensor for enhancing the signal conversion and thus improving detection accuracy and sensitivity, thus reaching unprecedented levels and having good application potential. This review describes the roles and contributions of typical carbon-based nanomaterials, such as mesoporous carbon, single- or multi-walled carbon nanotubes, graphene and carbon quantum dots, in the construction and performance improvement of various chemo- and biosensors for various signals. Additionally, this review focuses on the progress of applications of this type of sensor in food safety inspection, especially for the analysis and detection of all types of toxic and harmful substances in foods.
Collapse
Affiliation(s)
- Mingfei Pan
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science & Technology, Tianjin 300457, China.
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China.
| | - Zongjia Yin
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science & Technology, Tianjin 300457, China.
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China.
| | - Kaixin Liu
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science & Technology, Tianjin 300457, China.
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China.
| | - Xiaoling Du
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science & Technology, Tianjin 300457, China.
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China.
| | - Huilin Liu
- College of Food and Health, Beijing Technology and Business University, Beijing 100048, China.
| | - Shuo Wang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science & Technology, Tianjin 300457, China.
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China.
| |
Collapse
|
41
|
Gui R, Guo H, Jin H. Preparation and applications of electrochemical chemosensors based on carbon-nanomaterial-modified molecularly imprinted polymers. NANOSCALE ADVANCES 2019; 1:3325-3363. [PMID: 36133548 PMCID: PMC9419493 DOI: 10.1039/c9na00455f] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Accepted: 07/29/2019] [Indexed: 05/25/2023]
Abstract
The past few decades have witnessed a rapid development in electrochemical chemosensors (ECCSs). The integration of carbon nanomaterials (CNMs) and molecularly imprinted polymers (MIPs) has endowed ECCSs with high selectivity and sensitivity toward target detection. Due to the integrated merits of MIPs and CNMs, CNM-modified MIPs as ECCSs have been widely reported and have excellent detection applications. This review systematically summarized the general categories, preparation strategies, and applications of ECCSs based on CNM-modified MIPs. The categories include CNM-modified MIPs often hybridized with various materials and CNM-encapsulated or CNM-combined imprinting silica and polymers on working electrodes or other substrates. The preparation strategies include the polymerization of MIPs on CNM-modified substrates, co-polymerization of MIPs and CNMs on substrates, drop-casting of MIPs on CNM-modified substrates, self-assembly of CNMs/MIP complexes on substrates, and so forth. We discussed the in situ polymerization, electro-polymerization, and engineering structures of CNM-modified MIPs. With regard to potential applications, we elaborated the detection mechanisms, signal transducer modes, target types, and electrochemical sensing of targets in real samples. In addition, this review discussed the present status, challenges, and prospects of CNM-modified MIP-based ECCSs. This comprehensive review is desirable for scientists from broad research fields and can promote the further development of MIP-based functional materials, CNM-based hybrid materials, advanced composites, and hybrid materials.
Collapse
Affiliation(s)
- Rijun Gui
- College of Chemistry and Chemical Engineering, Intellectual Property Research Institute, Qingdao University Shandong 266071 PR China +86 532 85953981 +86 532 85953981
| | - Huijun Guo
- Advanced Fiber and Composites Research Institute, Jilin Institute of Chemical Technology Jilin 132022 PR China
| | - Hui Jin
- College of Chemistry and Chemical Engineering, Intellectual Property Research Institute, Qingdao University Shandong 266071 PR China +86 532 85953981 +86 532 85953981
| |
Collapse
|
42
|
Immobilization of a Novel ESTBAS Esterase from Bacillus altitudinis onto an Epoxy Resin: Characterization and Regioselective Synthesis of Chloramphenicol Palmitate. Catalysts 2019. [DOI: 10.3390/catal9070620] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Novel gene estBAS from Bacillus altitudinis, encoding a 216-amino acid esterase (EstBAS) with a signal peptide (SP), was expressed in Escherichia coli. EstBASΔSP showed the highest activity toward p-nitrophenyl hexanoate at 50 °C and pH 8.0 and had a half-life (T1/2) of 6 h at 50 °C. EstBASΔSP was immobilized onto a novel epoxy resin (Lx-105s) with a high loading of 96 mg/g. Fourier transform infrared (FTIR) spectroscopy showed that EstBASΔSP was successfully immobilized onto Lx-105s. In addition, immobilization improved its enzymatic performance by widening the tolerable ranges of pH and temperature. The optimum temperature of immobilized EstBASΔSP (Lx-EstBASΔSP) was higher, 60 °C, and overall thermostability improved. T1/2 of Lx-EstBASΔSP and free EstBASΔSP at 60 °C was 105 and 28 min, respectively. Lx-EstBASΔSP was used as a biocatalyst to synthesize chloramphenicol palmitate by regioselective modification at the primary hydroxyl group. Conversion efficiency reached 94.7% at 0.15 M substrate concentration after 24 h. Lx-EstBASΔSP was stable and could be reused for seven cycles, after which it retained over 80% of the original activity.
Collapse
|
43
|
Kumar A, Purohit B, Maurya PK, Pandey LM, Chandra P. Engineered Nanomaterial Assisted Signal‐amplification Strategies for Enhancing Analytical Performance of Electrochemical Biosensors. ELECTROANAL 2019. [DOI: 10.1002/elan.201900216] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- Ashutosh Kumar
- Laboratory of bio-physio sensors and nanobioengineering, Department of Biosciences and BioengineeringIndian Institute of Technology Guwahati Guwahati 781039 Assam India
- Department of Biosciences and BioengineeringIndian Institute of Technology Guwahati, Guwahati 781039 Assam India
| | - Buddhadev Purohit
- Laboratory of bio-physio sensors and nanobioengineering, Department of Biosciences and BioengineeringIndian Institute of Technology Guwahati Guwahati 781039 Assam India
- Department of Biosciences and BioengineeringIndian Institute of Technology Guwahati, Guwahati 781039 Assam India
| | - Pawan Kumar Maurya
- Department of BiochemistryCentral University of Haryana Mahendragarh 123031 Haryana India
| | - Lalit Mohan Pandey
- Department of Biosciences and BioengineeringIndian Institute of Technology Guwahati, Guwahati 781039 Assam India
| | - Pranjal Chandra
- Laboratory of bio-physio sensors and nanobioengineering, Department of Biosciences and BioengineeringIndian Institute of Technology Guwahati Guwahati 781039 Assam India
- Department of Biosciences and BioengineeringIndian Institute of Technology Guwahati, Guwahati 781039 Assam India
| |
Collapse
|
44
|
Vu VP, Tran QT, Pham DT, Tran PD, Thierry B, Chu TX, Mai AT. Possible detection of antibiotic residue using molecularly imprinted polyaniline-based sensor. VIETNAM JOURNAL OF CHEMISTRY 2019. [DOI: 10.1002/vjch.201900026] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Van-Phu Vu
- Laboratory for Microfabrication Technology and Pilot Plan Center; National Center for Technological Progress, 25 Le Thanh Tong; Hanoi Viet Nam
| | - Quang-Thinh Tran
- Laboratory for Microfabrication Technology and Pilot Plan Center; National Center for Technological Progress, 25 Le Thanh Tong; Hanoi Viet Nam
| | - Duc-Thanh Pham
- Laboratory for Microfabrication Technology and Pilot Plan Center; National Center for Technological Progress, 25 Le Thanh Tong; Hanoi Viet Nam
| | - Phu-Duy Tran
- Future Industries Institute and ARC Centre of Excellence for Convergent Nano-Bio Science and Technology; University of South Australia; Mawson Lakes South Australia Australia
| | - Benjamin Thierry
- Future Industries Institute and ARC Centre of Excellence for Convergent Nano-Bio Science and Technology; University of South Australia; Mawson Lakes South Australia Australia
| | - Thi-Xuan Chu
- International Institute for Materials Science (ITIMS); Hanoi University of Science and Technology, 1 Dai Co Viet Road; Hanoi Viet Nam
| | - Anh-Tuan Mai
- Laboratory for Microfabrication Technology and Pilot Plan Center; National Center for Technological Progress, 25 Le Thanh Tong; Hanoi Viet Nam
| |
Collapse
|
45
|
Taj A, Shaheen A, Xu J, Estrela P, Mujahid A, Asim T, Zubair Iqbal M, Khan WS, Bajwa SZ. In-situ synthesis of 3D ultra-small gold augmented graphene hybrid for highly sensitive electrochemical binding capability. J Colloid Interface Sci 2019; 553:289-297. [PMID: 31212228 DOI: 10.1016/j.jcis.2019.06.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 05/17/2019] [Accepted: 06/04/2019] [Indexed: 02/06/2023]
Abstract
The fascinating properties of graphene can be augmented with other nanomaterials to generate hybrids to design innovative applications. Contrary to the conventional methodologies, we showed a novel yet simple, in-situ, biological approach which allowed for the effective growth of gold nanostructures on graphene surfaces (3D Au NS@GO). The morphology of the obtained hybrid consisted of sheets of graphene, anchoring uniform dispersion of ultra-small gold nanostructures of about 2-8 nm diameter. Surface plasmon resonance at 380 nm confirmed the nano-regimen of the hybrid. Fourier transform infrared spectroscopy indicated the utilization of amine spacers to host gold ions leading to nucleation and growth. The exceptional positive surface potential of 55 mV suggest that the hybrid as an ideal support for electrocatalysis. Ultimately, the hybrid was found to be an efficient receptor material for electrochemical performance towards the binding of uric acid which is an important biomolecule of human metabolism. The designed material enabled the detection of uric acid concentrations as low as 30 nM. This synthesis strategy is highly suitable to design new hybrid materials with interesting morphology and outstanding properties for the identification of clinically relevant biomolecules.
Collapse
Affiliation(s)
- Ayesha Taj
- National Institute for Biotechnology and Genetic Engineering (NIBGE), P.O. Box No. 577, Jhang Road, Faisalabad, Pakistan; Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad, Pakistan
| | - Ayesha Shaheen
- National Institute for Biotechnology and Genetic Engineering (NIBGE), P.O. Box No. 577, Jhang Road, Faisalabad, Pakistan; Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad, Pakistan
| | - Jie Xu
- Department of Industrial and Mechanical Engineering, College of Engineering, University of Illinois at Chicago, Chicago, USA
| | - Pedro Estrela
- Centre of Biosensor Bioelectronics and Biodevices (C3Bio) and Department of Electronics and Electrical Engineering, University of Bath, Bath BA2 7AY, UK
| | - Adnan Mujahid
- Institute of Chemistry, University of the Punjab, Quaid-i-Azam Campus, Lahore 54590, Pakistan
| | - Tayyaba Asim
- Department of Environmental Science, Lahore College for Women University, Lahore 54590, Pakistan
| | - M Zubair Iqbal
- Department of Materials Engineering, College of Materials and Textiles, Zhejiang Sci-Tech University, No. 2 Road of Xiasha, Hangzhou 310018, PR China
| | - Waheed S Khan
- National Institute for Biotechnology and Genetic Engineering (NIBGE), P.O. Box No. 577, Jhang Road, Faisalabad, Pakistan.
| | - Sadia Z Bajwa
- National Institute for Biotechnology and Genetic Engineering (NIBGE), P.O. Box No. 577, Jhang Road, Faisalabad, Pakistan.
| |
Collapse
|
46
|
Qin X, Wang Q, Geng L, Shu X, Wang Y. A “signal-on” photoelectrochemical aptasensor based on graphene quantum dots-sensitized TiO2 nanotube arrays for sensitive detection of chloramphenicol. Talanta 2019; 197:28-35. [DOI: 10.1016/j.talanta.2018.12.103] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Revised: 11/26/2018] [Accepted: 12/31/2018] [Indexed: 02/07/2023]
|
47
|
Yadav M, Ganesan V, Gupta R, Yadav DK, Sonkar PK. Cobalt oxide nanocrystals anchored on graphene sheets for electrochemical determination of chloramphenicol. Microchem J 2019. [DOI: 10.1016/j.microc.2019.02.025] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
48
|
Detection of chloramphenicol in meat with a chemiluminescence resonance energy transfer platform based on molecularly imprinted graphene. Anal Chim Acta 2019; 1063:136-143. [PMID: 30967177 DOI: 10.1016/j.aca.2019.02.044] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Revised: 12/30/2018] [Accepted: 02/19/2019] [Indexed: 12/23/2022]
Abstract
In this study, a novel composite was synthesized by polymerizing the dummy-template molecularly imprinted microspheres on the surface of magnetic graphene. This composite was used as recognition reagent and energy acceptor to develop a platform for determination of chloramphenicol according to the principle of chemiluminescence resonance energy transfer. The light signal was induced with luminolH2O24-(imidazole-1-yl)phenol system, and the chemiluminescence intensity was positively correlated with the analyte concentration. The limit of detection for chloramphenicol in meat sample was 2.0 pg/g, and the recoveries from the standard fortified blank meat sample were in the range of 69.5%-97.3%. Furthermore, one single assay could be finished within 10 min, and the magnetic composite could be reused for at least thirty times. Therefore, this platform could be used as a rapid, simple, sensitive, accurate and recyclable tool for screening the residue of chloramphenicol in meat.
Collapse
|
49
|
Yuan Y, Xu X, Xia J, Zhang F, Wang Z, Liu Q. A hybrid material composed of reduced graphene oxide and porous carbon prepared by carbonization of a zeolitic imidazolate framework (type ZIF-8) for voltammetric determination of chloramphenicol. Mikrochim Acta 2019; 186:191. [DOI: 10.1007/s00604-019-3298-8] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Accepted: 02/02/2019] [Indexed: 01/08/2023]
|
50
|
Jia BJ, Huang J, Liu JX, Wang JP. Detection of chloramphenicol in chicken, pork and fish with a molecularly imprinted polymer-based microtiter chemiluminescence method. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2019; 36:74-83. [PMID: 30620682 DOI: 10.1080/19440049.2018.1562238] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
In this study, 4-nitrotoluene (NT) was used as dummy template to synthesize a molecularly imprinted polymer that was highly specific for chloramphenicol. The polymer was coated in the wells of 96-well microplates as recognition reagent to develop a chemiluminescence method. The analyte solution and an enzyme-labelled hapten were added into the wells to perform competition, and the light signal was induced with a highly efficient luminol-H2O2-4-(imidazol-1-yl)phenol system. Then, the optimized method was used to determine chloramphenicol in meat (chicken, pork and fish), and the limit of detection (LOD) was 5.0 pg g-1. Furthermore, the polymer-coated plate could be reused four times, and one test could be finished within 20 min. The recoveries from the standard fortified blank meat samples were in the range of 71.5-94.4%. Therefore, this method could be used as a useful tool for routine screening the residue of chloramphenicol in meat samples.
Collapse
Affiliation(s)
- Bing-Jie Jia
- a College of Veterinary Medicine , Hebei Agricultural University , Baoding , Hebei , China
| | - Jun Huang
- b Continuing Education College , Hebei Agricultural University , Baoding , Hebei , China
| | - Ju-Xiang Liu
- a College of Veterinary Medicine , Hebei Agricultural University , Baoding , Hebei , China
| | - Jian-Ping Wang
- a College of Veterinary Medicine , Hebei Agricultural University , Baoding , Hebei , China
| |
Collapse
|