1
|
Xu Z, Zhou H, Li L, Chen Z, Zhang X, Feng Y, Wang J, Li Y, Wu Y. Immunoassay System Based on the Technology of Time-Resolved Fluorescence Resonance Energy Transfer. SENSORS (BASEL, SWITZERLAND) 2024; 24:1430. [PMID: 38474966 DOI: 10.3390/s24051430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 02/17/2024] [Accepted: 02/20/2024] [Indexed: 03/14/2024]
Abstract
To enhance the specificity and sensitivity, cut the cost, and realize joint detection of multiple indicators, an immunoassay system based on the technology of time-resolved fluorescence resonance energy transfer (TR-FRET) was studied. Due to the FRET of the reagent, the donor probe and acceptor probe emitted specific fluorescence to enhance specificity. Long-lifetime specific fluorescence from the acceptor probe was combined with time-resolved technology to enhance sensitivity. A xenon flash lamp and a photomultiplier tube (PMT) were selected as the light source and detector, respectively. A filter-switching mechanism was placed in the light path, so the fluorescence signal from the donor and acceptor was measured alternately. The instrument's design is given, and some specificI parts are described in detail. Key technical specifications of the instrument and procalcitonin (PCT), C-reactive protein (CRP), and interleukin-6(IL-6) were tested, and the test results were presented subsequently. The CV value of the self-designed counting module is better than 0.01%, and the instrument noises for 620 nm and 665 nm are 41.44 and 10.59, respectively. When set at 37 °C, the temperature bias (B) is 0.06 °C, and the temperature fluctuation is 0.10 °C. The CV and bias are between ±3% and 5%, respectively, when pipetting volumes are between 10 μL and 100 μL. Within the concentration range of 0.01 nM to 10 nM, the luminescence values exhibit linear regression correlation coefficients greater than 0.999. For PCT detection, when the concentration ranges from 0.02 ng/mL to 50 ng/mL, the correlation coefficient of linear fitting exceeds 0.999, and the limit of quantification is 0.096 ng/mL. For CRP and IL-6, the detection concentration ranges from 0 ng/mL to 500 ng/mL and 0 ng/mL to 20 ng/mL, respectively, with limits of quantification of 2.70 ng/mL and 2.82 ng/mL, respectively. The experimental results confirm the feasibility of the technical and instrumental solutions.
Collapse
Affiliation(s)
- Zhengping Xu
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Hong Zhou
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Li Li
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Zhang Chen
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Xin Zhang
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Yongtong Feng
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Jianping Wang
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Yuan Li
- Chongqing Guoke Medical Innovation Technology Development Co., Ltd., Chongqing 401122, China
| | - Yanfan Wu
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| |
Collapse
|
2
|
He M, Xiao Y, Wei Y, Zheng B. Semiquantitative and visual detection of ferric ions in real samples using a fluorescent paper-based analytical device constructed with green emitting carbon dots. RSC Adv 2023; 13:31720-31727. [PMID: 37908650 PMCID: PMC10613948 DOI: 10.1039/d3ra05320b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2023] [Accepted: 10/20/2023] [Indexed: 11/02/2023] Open
Abstract
A simple and portable paper-based analytical device was developed for visual and semiquantitative detection of ferric ion in real samples using green emitting carbon dots (CDs), which were prepared via microwave method using sodium citrate, urea and sodium hydroxide as raw materials and then loaded on the surface of paper substrate. When Fe3+ exists, the green fluorescence of CDs was quenched and significant color change from green to dark blue were observed, resulting the visual detection of Fe3+ with a minimum distinguishable concentration of 100 μM. By analyzing the intensity changes of green channels of test paper with the help of smartphone, the semiquantitative detection was realized within the range of 100 μM to 1200 μM. The proposed paper-based analytical devices have great application prospects in on site detection of Fe3+ in real samples.
Collapse
Affiliation(s)
- Mengyuan He
- College of Chemistry and Chemical Engineering, Xinyang Normal University Xinyang 464000 China
| | - Yu Xiao
- College of Chemistry and Chemical Engineering, Xinyang Normal University Xinyang 464000 China
| | - Yuanhang Wei
- College of Chemistry and Chemical Engineering, Xinyang Normal University Xinyang 464000 China
| | - Bo Zheng
- College of Chemistry and Chemical Engineering, Xinyang Normal University Xinyang 464000 China
| |
Collapse
|
3
|
Karim K, Lamaoui A, Amine A. Paper-based optical sensors paired with smartphones for biomedical analysis. J Pharm Biomed Anal 2023; 225:115207. [PMID: 36584551 DOI: 10.1016/j.jpba.2022.115207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/07/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022]
Abstract
The traditional analytical methods used for biomedical analysis are expensive and not easy to handle and require sophisticated instruments, thus their application is limited in resource-limited settings. Due to their portability, low cost, and ability to be applied to different analytical techniques, paper-based analytical devices are becoming valuable tools for biomedical analysis. The integration of smartphones into analytical devices has provided the ability to build portable, cost-effective, straightforward analytical devices for biomedical analysis and mobile health. The key aim of this review is to emphasize the recent applications of PADs combined with a smartphone for the optical analysis of biomedical species. We started this review by highlighting the type of papers and their modifications with different materials to prepare the PADs. After that, this review presents various detection methods including colorimetry, fluorescence, and luminescence where the smartphone is used for read-out. In the end, we provided the recent applications of the analysis of different biomedical compounds such as cancer and cardiovascular biomarkers, metal ions, glucose, viruses, etc. We believe that the present review will attract a wide scientific community in the areas of analytical chemistry, sensors, and clinical testing.
Collapse
Affiliation(s)
- Khadija Karim
- Laboratoire Génie des Procedés & Environnement, Faculté des Sciences et Techniques, Hassan II University of Casablanca, B.P. 146, Mohammedia, Morocco
| | - Abderrahman Lamaoui
- Laboratoire Génie des Procedés & Environnement, Faculté des Sciences et Techniques, Hassan II University of Casablanca, B.P. 146, Mohammedia, Morocco
| | - Aziz Amine
- Laboratoire Génie des Procedés & Environnement, Faculté des Sciences et Techniques, Hassan II University of Casablanca, B.P. 146, Mohammedia, Morocco.
| |
Collapse
|
4
|
Liu X, Du K, Lin S, Wang Y. Deep learning on lateral flow immunoassay for the analysis of detection data. Front Comput Neurosci 2023; 17:1091180. [PMID: 36777694 PMCID: PMC9909280 DOI: 10.3389/fncom.2023.1091180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Accepted: 01/13/2023] [Indexed: 01/28/2023] Open
Abstract
Lateral flow immunoassay (LFIA) is an important detection method in vitro diagnosis, which has been widely used in medical industry. It is difficult to analyze all peak shapes through classical methods due to the complexity of LFIA. Classical methods are generally some peak-finding methods, which cannot distinguish the difference between normal peak and interference or noise peak, and it is also difficult for them to find the weak peak. Here, a novel method based on deep learning was proposed, which can effectively solve these problems. The method had two steps. The first was to classify the data by a classification model and screen out double-peaks data, and second was to realize segmentation of the integral regions through an improved U-Net segmentation model. After training, the accuracy of the classification model for validation set was 99.59%, and using combined loss function (WBCE + DSC), intersection over union (IoU) value of segmentation model for validation set was 0.9680. This method was used in a hand-held fluorescence immunochromatography analyzer designed independently by our team. A Ferritin standard curve was created, and the T/C value correlated well with standard concentrations in the range of 0-500 ng/ml (R 2 = 0.9986). The coefficients of variation (CVs) were ≤ 1.37%. The recovery rate ranged from 96.37 to 105.07%. Interference or noise peaks are the biggest obstacle in the use of hand-held instruments, and often lead to peak-finding errors. Due to the changeable and flexible use environment of hand-held devices, it is not convenient to provide any technical support. This method greatly reduced the failure rate of peak finding, which can reduce the customer's need for instrument technical support. This study provided a new direction for the data-processing of point-of-care testing (POCT) instruments based on LFIA.
Collapse
Affiliation(s)
- Xinquan Liu
- School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China,Xinquan Liu,
| | - Kang Du
- Tianjin Boomscience Technology Co., Ltd., Tianjin, China
| | - Si Lin
- School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China,Beijing Savant Biotechnology Co., Ltd., Beijing, China
| | - Yan Wang
- School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China,*Correspondence: Yan Wang,
| |
Collapse
|
5
|
Ghasemi F, Fahimi-Kashani N, Bigdeli A, Alshatteri AH, Abbasi-Moayed S, Al-Jaf SH, Merry MY, Omer KM, Hormozi-Nezhad MR. Paper-based optical nanosensors – A review. Anal Chim Acta 2022; 1238:340640. [DOI: 10.1016/j.aca.2022.340640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022]
|
6
|
Ma P, Wang S, Wang J, Wang Y, Dong Y, Li S, Su H, Chen P, Feng X, Li Y, Du W, Liu BF. Rapid Assembly of Cellulose Microfibers into Translucent and Flexible Microfluidic Paper-Based Analytical Devices via Wettability Patterning. Anal Chem 2022; 94:13332-13341. [PMID: 36121740 DOI: 10.1021/acs.analchem.2c01424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Microfluidic paper-based analytical devices (μPADs) are emerging as powerful analytical platforms in clinical diagnostics, food safety, and environmental protection because of their low cost and favorable substrate properties for biosensing. However, the existing top-down fabrication methods of paper-based chips suffer from low resolution (>200 μm). Additionally, papers have limitations in their physical properties (e.g., thickness, transmittance, and mechanical flexibility). Here, we demonstrate a bottom-up approach for the rapid fabrication of heterogeneously controlled paper-based chip arrays. We simply print a wax-patterned microchip with wettability contrasts, enabling automatic and selective assembly of cellulose microfibers to construct predefined paper-based microchip arrays with controllable thickness. This paper-based microchip printing technology is feasible for various substrate materials ranging from inorganic glass to organic polymers, providing a versatile platform for the full range of applications including transparent devices and flexible health monitoring. Our bottom-up printing technology using cellulose microfibers as the starting material provides a lateral resolution down to 42 ± 3 μm and achieves the narrowest channel barrier down to 33 ± 2 μm. As a proof-of-concept demonstration, a flexible paper-based glucose monitor is built for human health care, requiring only 0.3 μL of sample for testing.
Collapse
Affiliation(s)
- Peng Ma
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Shanshan Wang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.,BGI-Shenzhen, Shenzhen 518083, China
| | - Jie Wang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Yu Wang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Yue Dong
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Shunji Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Huiying Su
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.,School of Biological Engineering, Huainan Normal University, Huainan, Anhui 232038, China
| | - Peng Chen
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Xiaojun Feng
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Yiwei Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Wei Du
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Bi-Feng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
7
|
Yang J, Cheng Y, Gong X, Yi S, Li CW, Jiang L, Yi C. An integrative review on the applications of 3D printing in the field of in vitro diagnostics. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2021.08.105] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
8
|
Wang L, Li B, Wang J, Qi J, Li J, Ma J, Chen L. A rotary multi-positioned cloth/paper hybrid microfluidic device for simultaneous fluorescence sensing of mercury and lead ions by using ion imprinted technologies. JOURNAL OF HAZARDOUS MATERIALS 2022; 428:128165. [PMID: 35007967 DOI: 10.1016/j.jhazmat.2021.128165] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/15/2021] [Accepted: 12/25/2021] [Indexed: 05/14/2023]
Abstract
A novel rotary cloth/paper hybrid microfluidic analytical device (μCPAD) was proposed via the synergy of the fluorescence sensing cloth-based component and rotary paper-based microfluidic analytical device (μPAD) for simultaneous detection of mercury (Hg2+) and lead (Pb2+) ions. Fluorescence sensing cloth-based component was prepared by grafting quantum dots onto cotton cloth and then modifying with ion imprinted polymers (IIP). Because the cloth has good ductility and durability, it can bear strong oscillation during the fabrication of grafting quantum dots and IIP, and brings a lot of convenience to the production process. At the same time, because rotary μCPAD was stacked by three-layer papers with designed hydrophilic channels and hydrophobic barriers, it could realize simultaneous detection of Hg2+ and Pb2+ ions by rotating top layer counterclockwise or clockwise. The fluorescence signals were obtained through quantum dots' electron transfer fluorescence quenching effect with the limits of detection were 0.18 and 0.07 μg/L, respectively. This method successfully realized the transference of specific and sensitive fluorescence sensing materials (quantum dots) onto the microfluidic device to improve the portability and expanded applications. Moreover, the novel microfluidic device may have great potential in point-of-care testing of heavy metal ions in environmental monitoring fields.
Collapse
Affiliation(s)
- Liyan Wang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering Technology of Shandong Province, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China; Department of Polymer Chemistry, Yantai Engineering & Technology College, Yantai 264006, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Bowei Li
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering Technology of Shandong Province, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China.
| | - Jianan Wang
- School of Civil Engineering, Yantai University, Yantai 264005, China
| | - Ji Qi
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering Technology of Shandong Province, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
| | - Jinhua Li
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering Technology of Shandong Province, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jiping Ma
- School of Environmental & Municipal Engineering, State-Local Joint Engineering Research Center of Urban Sewage Treatment and Resource Recovery, Qingdao University of Technology, Qingdao 266033, China
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering Technology of Shandong Province, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China.
| |
Collapse
|
9
|
Boranna R, Nataraj CT, Bannur Nanjunda S, Pahal S, Jagannath RK, Prashanth GR. Fluorescence Signal Enhancement by a Spray-Assisted Layer-by-Layer Technique on Aluminum Tape Devices for Biosensing Applications. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:3149-3157. [PMID: 35235318 DOI: 10.1021/acs.langmuir.1c03186] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Layer-by-layer (LbL) self-assembled polyelectrolyte multilayer (PEM) films are a simple yet elegant bottom-up technology to create films at the nano-microscale. This low-cost technology has been widely used as a universal functionalization technique on a broad spectrum of substrates. Biomolecules under investigation can be incubated onto films based on complementary charge interactions between the films and biomolecules. There is a great demand for developing an ultralow-cost biosensing device, which can optimally enhance the fluorescence signal of the adsorbed biomolecules from the traditional labeled sensing platforms. In this work, we have incorporated a blend of the conventional metal enhanced fluorescence technology and the PEM as a dielectric spacer and functionalized film, coated on an aluminum paper (tape)-based substrate. These device has been found to be capable of holding biomolecules in three-dimensional PEM space. The devices fabricated by the proposed spray LbL technique provide significant fluorescence signal enhancement by holding a relatively higher mass per volume of the adsorbed biomolecules, when compared to traditional spin- and dip-coating techniques. Interestingly, our proposed device has expressed a fluorescence enhancement factor, which is 9 times higher than PEM-functionalized glass-based devices. To demonstrate the practical utility of our devices, we also compared our devices to Whatman FAST slides. Our experimental fluorescence results are almost comparable to Whatman FAST slides. Such PEM devices fabricated on top of low-cost aluminum tape using a spray LbL technique give new insights into the future development of ultralow-cost, high-throughput, and disposable lab-on-chip diagnostic applications.
Collapse
Affiliation(s)
- Rakshith Boranna
- Department of Electronics and Communication Engineering, National Institute of Technology Goa, Farmagudi, Ponda, Goa 403401, India
| | - Chandrika Thondagere Nataraj
- Department of Electronics and Telecommunication Engineering, Siddaganga Institute of Technology, Tumkuru, Karnataka 572103, India
| | - Shivananju Bannur Nanjunda
- Department of Electrical Engineering, Centre of Excellence in Biochemical Sensing and Imaging Technologies (Cen-Bio-SIM), Indian Institute of Technology Madras, Chennai, Tamil Nadu 600036, India
| | - Suman Pahal
- Centre for Nano Science and Engineering, Indian Institute of Science, Bengaluru, Karnataka 560012, India
| | | | - Gurusiddappa R Prashanth
- Department of Electronics and Communication Engineering, National Institute of Technology Goa, Farmagudi, Ponda, Goa 403401, India
| |
Collapse
|
10
|
Upconversion fluorescence-based paper disc for multiplex point-of-care testing in water quality monitoring. Anal Chim Acta 2022; 1192:339388. [DOI: 10.1016/j.aca.2021.339388] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 12/02/2021] [Accepted: 12/18/2021] [Indexed: 12/12/2022]
|
11
|
Pang R, Zhu Q, Wei J, Meng X, Wang Z. Enhancement of the Detection Performance of Paper-Based Analytical Devices by Nanomaterials. Molecules 2022; 27:508. [PMID: 35056823 PMCID: PMC8779822 DOI: 10.3390/molecules27020508] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Revised: 12/29/2021] [Accepted: 01/10/2022] [Indexed: 12/01/2022] Open
Abstract
Paper-based analytical devices (PADs), including lateral flow assays (LFAs), dipstick assays and microfluidic PADs (μPADs), have a great impact on the healthcare realm and environmental monitoring. This is especially evident in developing countries because PADs-based point-of-care testing (POCT) enables to rapidly determine various (bio)chemical analytes in a miniaturized, cost-effective and user-friendly manner. Low sensitivity and poor specificity are the main bottlenecks associated with PADs, which limit the entry of PADs into the real-life applications. The application of nanomaterials in PADs is showing great improvement in their detection performance in terms of sensitivity, selectivity and accuracy since the nanomaterials have unique physicochemical properties. In this review, the research progress on the nanomaterial-based PADs is summarized by highlighting representative recent publications. We mainly focus on the detection principles, the sensing mechanisms of how they work and applications in disease diagnosis, environmental monitoring and food safety management. In addition, the limitations and challenges associated with the development of nanomaterial-based PADs are discussed, and further directions in this research field are proposed.
Collapse
Affiliation(s)
- Renzhu Pang
- Department of Thyroid Surgery, The First Hospital of Jilin University, Changchun 130021, China; (R.P.); (J.W.)
| | - Qunyan Zhu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China;
| | - Jia Wei
- Department of Thyroid Surgery, The First Hospital of Jilin University, Changchun 130021, China; (R.P.); (J.W.)
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China;
| | - Xianying Meng
- Department of Thyroid Surgery, The First Hospital of Jilin University, Changchun 130021, China; (R.P.); (J.W.)
| | - Zhenxin Wang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China;
- School of Applied Chemical Engineering, University of Science and Technology of China, Hefei 230026, China
| |
Collapse
|
12
|
Wang L, Li B, Li J, Qi J, Zhang Z, Chen L. An ion imprinting technology-assisted rotational microfluidic hybrid chip for the fluorescence detection of hexavalent chromium ions. Analyst 2022; 147:3756-3763. [DOI: 10.1039/d2an00896c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
An ion imprinted fluorescence sensing rotational microfluidic paper- and cloth-based hybrid chip was developed for hexavalent chromium detection.
Collapse
Affiliation(s)
- Liyan Wang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering Technology of Shandong Province, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
- Department of Polymer Chemistry, Yantai Engineering & Technology College, Yantai 264006, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Bowei Li
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering Technology of Shandong Province, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, 266071, China
| | - Jinhua Li
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering Technology of Shandong Province, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, 266071, China
| | - Ji Qi
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering Technology of Shandong Province, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, 266071, China
| | - Zhiyang Zhang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering Technology of Shandong Province, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, 266071, China
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Research Center for Coastal Environmental Engineering Technology of Shandong Province, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, 266071, China
- School of Pharmacy, Binzhou Medical University, Yantai 264003, China
| |
Collapse
|
13
|
Yamaguchi A, Miyaguchi H, Ishida A, Tokeshi M. Paper-Based Analytical Device for the On-Site Detection of Nerve Agents. ACS APPLIED BIO MATERIALS 2021; 4:6512-6518. [PMID: 35006863 DOI: 10.1021/acsabm.1c00655] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We report a colorimetric paper-based microfluidic device based on an enzyme inhibition assay that allows the on-site detection of nerve agents by sampling and wicking. The sample and reagents are automatically transported through the channel where an enzyme inhibition reaction is conducted, followed by an enzyme-substrate reaction and a color reaction. This device can detect 0.1 μg/mL of the nerve agent VX in a 2.5 μL drop and is nerve agent selective and robust against temperature, pH, and several liquids. We confirmed that sampling procedures (dilution and wiping) are applicable to this device. Furthermore, the fabrication procedure is easy, and the cost is at most a few tens of cents. Thus, the present device provides a practical method for the urgent detection of nerve agents in suspected chemical terrorism incidents.
Collapse
Affiliation(s)
- Akinori Yamaguchi
- National Research Institute of Police Science, 6-3-1 Kashiwanoha, Kashiwa 277-0882, Japan.,Graduate School of Chemical Sciences and Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan
| | - Hajime Miyaguchi
- National Research Institute of Police Science, 6-3-1 Kashiwanoha, Kashiwa 277-0882, Japan
| | - Akihiko Ishida
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan
| | - Manabu Tokeshi
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan.,Innovative Research Centre for Preventive Medical Engineering, Nagoya University, Furo-cho Chikusa-ku, Nagoya 464-8601, Japan.,Institutes of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan
| |
Collapse
|
14
|
Noviana E, Ozer T, Carrell CS, Link JS, McMahon C, Jang I, Henry CS. Microfluidic Paper-Based Analytical Devices: From Design to Applications. Chem Rev 2021; 121:11835-11885. [DOI: 10.1021/acs.chemrev.0c01335] [Citation(s) in RCA: 91] [Impact Index Per Article: 30.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Eka Noviana
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Universitas Gadjah Mada, Yogyakarta, Indonesia 55281
| | - Tugba Ozer
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department of Bioengineering, Faculty of Chemical and Metallurgical Engineering, Yildiz Technical University, Istanbul, Turkey 34220
| | - Cody S. Carrell
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Jeremy S. Link
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Catherine McMahon
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Ilhoon Jang
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Institute of Nano Science and Technology, Hanyang University, Seoul, South Korea 04763
| | - Charles S. Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
15
|
He M, Shang N, Shen L, Liu Z. A paper-supported sandwich immunosensor based on upconversion luminescence resonance energy transfer for the visual and quantitative determination of a cancer biomarker in human serum. Analyst 2021; 145:4181-4187. [PMID: 32400772 DOI: 10.1039/c9an02307k] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this paper, a paper-supported analytical device based on a sandwich immunoreaction and luminescence resonance energy transfer (LRET) was reported for the visual and quantitative determination of a cancer biomarker, in which upconversion nanoparticles (UCNPs) were located on the surface of the paper as energy donors and gold nanoparticles (AuNPs) were used as energy acceptors. Upon the recognition of the cancer biomarker by two rationally selected antibodies, the upconversion luminescence was quenched by the AuNPs in a biomarker concentration-dependent manner. As a model target, CEA was detected using this immunosensor, and a linear relationship within 0.5-30 ng mL-1 was obtained in buffer solution, with a detection limit of 0.21 ng mL-1. The immunosensor was also applicable in 20-fold diluted human serum with a linear range of 0.5-30 ng mL-1 and a detection limit of 0.36 ng mL-1. This technique also realized the qualitative judgment of the critical concentration of CEA in serum samples by the naked eye. This approach displays great application potential for point-of-care testing in clinical applications, as well as the potentiality to be extended to other kinds of disease-related biomolecules.
Collapse
Affiliation(s)
- Mengyuan He
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang 464000, China.
| | - Ning Shang
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang 464000, China.
| | - Lin Shen
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China.
| | - Zhihong Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China.
| |
Collapse
|
16
|
Fang H, Wu M, Ji W, Wang L, Chen Y, Chen D, Yang N, Wu Q, Yu C, Liu J, Liu J, Bai H, Peng B, Huang X, Yu HD, Li L. Simultaneously Detecting Monoamine Oxidase A and B in Disease Cell/Tissue Samples Using Paper-Based Devices. ACS APPLIED BIO MATERIALS 2021; 4:1395-1402. [PMID: 35014490 DOI: 10.1021/acsabm.0c01288] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
As enzymes in the outer membrane of the mitochondrion, monoamine oxidases (MAOs) can catalyze the oxidative deamination of monoamines in the human body. According to different substrates, MAOs can be divided into MAO-A and MAO-B. The imbalance of the MAO-A is associated with neurological degeneration, while excess MAO-B activity is closely connected with Parkinson's disease (PD) and Alzheimer's disease (AD); therefore, detection of MAOs is of great significance for the diagnosis and treatment of these diseases. This work reports the multiplexed detection of MAO-A and MAO-B using paper-based devices based on chemiluminescence (CL). The detection limits were 5.01 pg/mL for MAO-A and 8.50 pg/mL for MAO-B in human serum. In addition, we used paper-based devices to detect MAOs in human cells and tissue samples and found that the results of paper-based detection and Western blotting (WB) showed the same trend. While only one antibody can be incubated on the same membrane by WB, multiple antibodies incubated on the same paper enabled simultaneous detection of MAO-A and MAO-B by paper-based devices. The paper-based assay could be used for preliminary early screening of clinical samples for MAOs and can be extended as an alternative to WB for multiplexed detection of various proteins in disease cell or tissue samples.
Collapse
Affiliation(s)
- Haixiao Fang
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Meirong Wu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Wenhui Ji
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Limin Wang
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, P. R. China
| | - Yipei Chen
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, P. R. China
| | - Ding Chen
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Naidi Yang
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Qiong Wu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Changmin Yu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Jie Liu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Jinhua Liu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Hua Bai
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, P. R. China
| | - Bo Peng
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, P. R. China
| | - Xiao Huang
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| | - Hai-Dong Yu
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China.,Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, P. R. China
| | - Lin Li
- Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China
| |
Collapse
|
17
|
Li W, Zhang X, Li T, Ji Y, Li R. Molecularly imprinted polymer-enhanced biomimetic paper-based analytical devices: A review. Anal Chim Acta 2021; 1148:238196. [PMID: 33516379 DOI: 10.1016/j.aca.2020.12.071] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Revised: 12/29/2020] [Accepted: 12/30/2020] [Indexed: 02/07/2023]
Abstract
The popularization of paper-based analytical devices (PADs) in analytical science has fostered research on enhancing their analytical performance for accurate and sensitive assays. With their superb recognition capability and structural stability, molecularly imprinted polymers (MIPs) have been extensively employed as biomimetic receptors for capturing target analytes in various complex matrices. The integration of MIPs as recognition elements with PADs (MIP-PADs) has opened new opportunities for advanced analytical devices with elevated selectivity and sensitivity, as well as a shorter assay time and a lower cost. This review covers recent advances in MIP-PAD fabrication and engineering based on multifarious signal transduction systems such as colorimetry, fluorescence, electrochemistry, photoelectrochemistry, and chemiluminescence. The application of MIP-PADs in the fields of biomedical diagnostics, environmental analysis, and food safety monitoring is also reviewed. Further, the advantages, challenges, and perspectives of MIP-PADs are discussed.
Collapse
Affiliation(s)
- Wang Li
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009, China
| | - Xiaoyue Zhang
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009, China
| | - Tingting Li
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009, China
| | - Yibing Ji
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009, China.
| | - Ruijun Li
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009, China.
| |
Collapse
|
18
|
Zhang X, Chen S, Zhuo S, Ji Y, Li R. A carbon dots functionalized paper coupled with AgNPs composites platform: application as a sensor for hydrogen peroxide detection based on surface plasmon-enhanced energy transfer. NEW J CHEM 2021. [DOI: 10.1039/d0nj05721e] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
A paper-based fluorescent sensor (PCD/AgNPs) consisted of CDs functionalized paper and AgNPs was developed for sensing H2O2 in milk samples and cancer cells.
Collapse
Affiliation(s)
- Xiaoyue Zhang
- Department of Analytical Chemistry
- China Pharmaceutical University
- Nanjing 210009
- China
- Key Laboratory of Drug Quality Control and Pharmacovigilance
| | - Siqi Chen
- Department of Analytical Chemistry
- China Pharmaceutical University
- Nanjing 210009
- China
- Key Laboratory of Drug Quality Control and Pharmacovigilance
| | - Siqi Zhuo
- Department of Analytical Chemistry
- China Pharmaceutical University
- Nanjing 210009
- China
- Key Laboratory of Drug Quality Control and Pharmacovigilance
| | - Yibing Ji
- Department of Analytical Chemistry
- China Pharmaceutical University
- Nanjing 210009
- China
- Key Laboratory of Drug Quality Control and Pharmacovigilance
| | - Ruijun Li
- Department of Analytical Chemistry
- China Pharmaceutical University
- Nanjing 210009
- China
- Key Laboratory of Drug Quality Control and Pharmacovigilance
| |
Collapse
|
19
|
Ji T, Xu X, Wang X, Cao N, Han X, Wang M, Chen B, Lin Z, Jia H, Deng M, Xia Y, Guo X, Lei M, Liu Z, Zhou Q, Chen G. Background-Free Chromatographic Detection of Sepsis Biomarker in Clinical Human Serum through Near-Infrared to Near-Infrared Upconversion Immunolabeling. ACS NANO 2020; 14:16864-16874. [PMID: 33295753 DOI: 10.1021/acsnano.0c05700] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Luminescence nanomaterial-based lateral flow assay (LFA) is promising for point-of-care tests. However, the detection sensitivity and accuracy are often affected by the interferences of autofluorescence and photon scattering from nitrocellulose membrane and colored plasma. Here, we describe a near-infrared to near-infrared upconversion nanoparticle (UCNP) immunolabeled LFA for background-free chromatographic detection of sepsis biomarker procalcitonin (PCT) in clinical human plasma. This upconversion immunolabeling enables both light excitation (at ∼980 nm) and anti-Stokes emission (at 800 nm) to be adopted within the first biological window (700-1000 nm), which eliminates background autofluorescence as well as photon scattering interferences, empowering a high-sensitivity detection without complicated procedures. After optimization, the described assay presented a limit of detection reaching down to 0.03 ng/mL, lower than the normal level (0.05 ng/mL), while having a detection range of 0.03-50 ng/mL that covers the clinical PCT level of interest (0.5-10 ng/mL). The assay recoveries in human serum samples were evaluated to be about 95-110%, whereas the inter- and intra-assay coefficient variations were both determined to be below 15%. Importantly, measured PCT concentrations in clinical samples are in good correlation with that of the electrochemiluminescence immunoassay (Roche) widely applied in large clinical settings. This near-infrared to near-infrared upconversion immunolabeling approach has direct implications for ultrasensitive and background-free point-of-care detection of other serum biomarkers in resource-limited clinical settings.
Collapse
Affiliation(s)
- Tianxing Ji
- Clinical Laboratory Medicine, The Second Affiliated Hospital of Guangzhou Medical University, Guangzhou 510260, China
| | - Xinqiang Xu
- MIIT Key Laboratory of Critical Materials Technology for New Energy Conversion and Storage, School of Chemistry and Chemical Engineering & Key Laboratory of Micro-systems and Micro-Structures, Ministry of Education, Harbin Institute of Technology, Harbin 150001, China
- Clinical Laboratory Medicine, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510260, China
| | - Xindong Wang
- MIIT Key Laboratory of Critical Materials Technology for New Energy Conversion and Storage, School of Chemistry and Chemical Engineering & Key Laboratory of Micro-systems and Micro-Structures, Ministry of Education, Harbin Institute of Technology, Harbin 150001, China
| | - Ning Cao
- Department of Learning and Instruction, University at Buffalo, State University of New York, Buffalo, New York 14260, United States
| | - Xiaorui Han
- MIIT Key Laboratory of Critical Materials Technology for New Energy Conversion and Storage, School of Chemistry and Chemical Engineering & Key Laboratory of Micro-systems and Micro-Structures, Ministry of Education, Harbin Institute of Technology, Harbin 150001, China
| | - Minhong Wang
- Clinical Laboratory Medicine, The Second Affiliated Hospital of Guangzhou Medical University, Guangzhou 510260, China
| | - Bo Chen
- Clinical Laboratory Medicine, The Second Affiliated Hospital of Guangzhou Medical University, Guangzhou 510260, China
| | - Zhen Lin
- Clinical Laboratory Medicine, The Second Affiliated Hospital of Guangzhou Medical University, Guangzhou 510260, China
| | - Hongyun Jia
- Clinical Laboratory Medicine, The Second Affiliated Hospital of Guangzhou Medical University, Guangzhou 510260, China
| | - Min Deng
- Clinical Laboratory Medicine, The Second Affiliated Hospital of Guangzhou Medical University, Guangzhou 510260, China
| | - Yong Xia
- Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou 510150, China
| | - Xuguang Guo
- Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou 510150, China
| | - Meng Lei
- Clinical Laboratory Medicine, Yichun People's Hospital, Yichun 336000, China
| | - Zhenwei Liu
- State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510120, China
| | - Qiang Zhou
- Clinical Laboratory Medicine, The Second Affiliated Hospital of Guangzhou Medical University, Guangzhou 510260, China
| | - Guanying Chen
- MIIT Key Laboratory of Critical Materials Technology for New Energy Conversion and Storage, School of Chemistry and Chemical Engineering & Key Laboratory of Micro-systems and Micro-Structures, Ministry of Education, Harbin Institute of Technology, Harbin 150001, China
| |
Collapse
|
20
|
Progress in Rapid Detection Techniques Using Paper-Based Platforms for Food Safety. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2020. [DOI: 10.1016/s1872-2040(20)60064-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
21
|
He M, Shang N, Zhu Q, Xu J. Paper-based upconversion fluorescence aptasensor for the quantitative detection of immunoglobulin E in human serum. Anal Chim Acta 2020; 1143:93-100. [PMID: 33384135 DOI: 10.1016/j.aca.2020.11.036] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 11/09/2020] [Accepted: 11/23/2020] [Indexed: 10/22/2022]
Abstract
Immunoglobulin E (IgE), a biomarker of allergic diseases, plays a critical role in allergic mechanism. Because of its low abundance in serum, the demand of developing sensitive, selective and simple methods for IgE detection is still very urgent. Paper-based analytical devices using upconversion nanoparticles (UCNPs) as the label can be promising point-of-care test (POCT) methods in rapid diagnosis, owing to their NIR-excitation and visible light emission nature, which can avoid the interference of autofluorescence and scattering light from biological samples and paper substrates. In this work, we proposed a paper-based analytical device for the sensitive, selective and accurate detection of total immunoglobulin E (IgE) in human serum. The assay was based on resonance energy transfer between UCNPs and organic dye tetramethylrhodamine (TAMRA), and IgE aptamer with stem-loop structure was used as the recognizing probe. The existence of IgE change the conformation of IgE aptamer, enlarge the distance between donor and acceptor, and block the energy transfer process. Thus, the luminescence of UCNPs recovered with an IgE concentration independent manner. A linear calibration was obtained in the range of 0.5-50 IU/mL, with a detection limit of 0.13 IU/mL. The results of our method were well correlated with that of commercial ELISA kit (20 human serum samples). This work suggests promising prospect of the paper-based UC-LRET analytical devices in real samples and may promote the application of paper-based analytical devices in clinical diagnosis.
Collapse
Affiliation(s)
- Mengyuan He
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, 464000, China.
| | - Ning Shang
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, 464000, China
| | - Qianru Zhu
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, 464000, China
| | - Jing Xu
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, 464000, China
| |
Collapse
|
22
|
Sensors and microarrays in protein biomarker monitoring: an electrochemical perspective spots. Bioanalysis 2020; 12:1337-1345. [PMID: 32915086 DOI: 10.4155/bio-2020-0166] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
The development of clinically applicable portable sensors and multiplex protein biomarker assays is one of the most important goals of laboratory medicine today. Sensing strategies based on electrochemical devices are discussed in this overview, with special emphasis on detection principles derived from voltammetry, electrogenerated chemiluminescence, bipolar electrochemistry and impedance-based measurements. Up-to-date examples of electrochemical methods in biomedical research and development are highlighted here, including critical evaluation and future directions of the analysis, development and validation of new protein biomarkers.
Collapse
|
23
|
Komatsu T, Maeki M, Ishida A, Tani H, Tokeshi M. Paper-Based Device for the Facile Colorimetric Determination of Lithium Ions in Human Whole Blood. ACS Sens 2020; 5:1287-1294. [PMID: 32283919 DOI: 10.1021/acssensors.9b02218] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Lithium carbonate is an effective medicine for the treatment of the bipolar disorder, but the concentration of lithium in the patient's blood must be frequently monitored because of its toxicity. To date, no colorimetric methods of lithium ion detection in whole blood without pretreatment have been reported. Here, we report a colorimetric paper-based device that allows point-of-care testing in one step. This device is composed of two paper-based elements linked to each other: a blood cell separation unit and a colorimetric detection unit. After a portion of whole blood has been placed on the end of the separation unit, plasma in the sample is automatically transported to the detection unit, which displays a diagnostic color. The key feature of this device is its simple, user-friendly operation. The limit of detection is 0.054 mM and the coefficient of variance is below 6.1%, which are comparable to those of conventional instruments using the same colorimetric reaction. Furthermore, we achieved high recovery (>90%) and reproducibility (<9.8%) with spiked human blood samples. Thus, the presented device provides an alternative method for the regular monitoring of lithium concentrations in the treatment of bipolar disorder by augmenting the coefficient of variation (maximum value, 6.1%).
Collapse
Affiliation(s)
- Takeshi Komatsu
- Graduate School of Chemical Sciences and Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
| | - Masatoshi Maeki
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
| | - Akihiko Ishida
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
| | - Hirofumi Tani
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
| | - Manabu Tokeshi
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
- Innovative Research Centre for Preventive Medical Engineering, Nagoya University, Furo-cho, Chikusa, Nagoya 464-8601, Japan
- Institute of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa, Nagoya 464-8601, Japan
| |
Collapse
|
24
|
Van Gool A, Corrales F, Čolović M, Krstić D, Oliver-Martos B, Martínez-Cáceres E, Jakasa I, Gajski G, Brun V, Kyriacou K, Burzynska-Pedziwiatr I, Wozniak LA, Nierkens S, Pascual García C, Katrlik J, Bojic-Trbojevic Z, Vacek J, Llorente A, Antohe F, Suica V, Suarez G, t'Kindt R, Martin P, Penque D, Martins IL, Bodoki E, Iacob BC, Aydindogan E, Timur S, Allinson J, Sutton C, Luider T, Wittfooth S, Sammar M. Analytical techniques for multiplex analysis of protein biomarkers. Expert Rev Proteomics 2020; 17:257-273. [PMID: 32427033 DOI: 10.1080/14789450.2020.1763174] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
INTRODUCTION The importance of biomarkers for pharmaceutical drug development and clinical diagnostics is more significant than ever in the current shift toward personalized medicine. Biomarkers have taken a central position either as companion markers to support drug development and patient selection, or as indicators aiming to detect the earliest perturbations indicative of disease, minimizing therapeutic intervention or even enabling disease reversal. Protein biomarkers are of particular interest given their central role in biochemical pathways. Hence, capabilities to analyze multiple protein biomarkers in one assay are highly interesting for biomedical research. AREAS COVERED We here review multiple methods that are suitable for robust, high throughput, standardized, and affordable analysis of protein biomarkers in a multiplex format. We describe innovative developments in immunoassays, the vanguard of methods in clinical laboratories, and mass spectrometry, increasingly implemented for protein biomarker analysis. Moreover, emerging techniques are discussed with potentially improved protein capture, separation, and detection that will further boost multiplex analyses. EXPERT COMMENTARY The development of clinically applied multiplex protein biomarker assays is essential as multi-protein signatures provide more comprehensive information about biological systems than single biomarkers, leading to improved insights in mechanisms of disease, diagnostics, and the effect of personalized medicine.
Collapse
Affiliation(s)
- Alain Van Gool
- Translational Metabolic Laboratory, Department of Laboratory Medicine, Radboud Institute of Molecular Life Sciences, Radboud University Medical Center , Nijmegen, The Netherlands
| | - Fernado Corrales
- Functional Proteomics Laboratory, Centro Nacional De Biotecnología , Madrid, Spain
| | - Mirjana Čolović
- Department of Physical Chemistry, "Vinča" Institute of Nuclear Sciences, University of Belgrade , Belgrade, Serbia
| | - Danijela Krstić
- Institute of Medical Chemistry, Faculty of Medicine, University of Belgrade , Belgrade, Serbia
| | - Begona Oliver-Martos
- Neuroimmunology and Neuroinflammation Group. Instituto De Investigación Biomédica De Málaga-IBIMA. UGC Neurociencias, Hospital Regional Universitario De Málaga , Malaga, Spain
| | - Eva Martínez-Cáceres
- Immunology Division, LCMN, Germans Trias I Pujol University Hospital and Research Institute, Campus Can Ruti, Badalona, and Department of Cellular Biology, Physiology and Immunology, Universitat Autònoma De Barcelona , Cerdanyola Del Vallès, Spain
| | - Ivone Jakasa
- Laboratory for Analytical Chemistry, Department of Chemistry and Biochemistry, Faculty of Food Technology and Biotechnology, University of Zagreb , Zagreb, Croatia
| | - Goran Gajski
- Mutagenesis Unit, Institute for Medical Research and Occupational Health , Zagreb, Croatia
| | - Virginie Brun
- Université Grenoble Alpes, CEA, Inserm, IRIG, BGE , Grenoble, France
| | - Kyriacos Kyriacou
- Department of Electron Microscopy/Molecular Biology, The Cyprus School of Molecular Medicine/The Cyprus Institute of Neurology and Genetics , Nicosia, Cyprus
| | - Izabela Burzynska-Pedziwiatr
- Medical Faculty, Department of Biomedical Sciences, Chair of Medical Biology & Department of Structural Biology, Medical University of Lodz , Łódź, Poland
| | - Lucyna Alicja Wozniak
- Medical Faculty, Department of Biomedical Sciences, Chair of Medical Biology & Department of Structural Biology, Medical University of Lodz , Łódź, Poland
| | - Stephan Nierkens
- Center for Translational Immunology, University Medical Center Utrecht & Princess Máxima Center for Pediatric Oncology , Utrecht, The Netherlands
| | - César Pascual García
- Materials Research and Technology Department, Luxembourg Institute of Science and Technology (LIST) , Belvaux, Luxembourg
| | - Jaroslav Katrlik
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences , Bratislava, Slovakia
| | - Zanka Bojic-Trbojevic
- Laboratory for Biology of Reproduction, Institute for the Application of Nuclear Energy - INEP, University of Belgrade , Belgrade, Serbia
| | - Jan Vacek
- Department of Medical Chemistry and Biochemistry, Faculty of Medicine and Dentistry, Palacky University , Olomouc, Czech Republic
| | - Alicia Llorente
- Department of Molecular Cell Biology, Institute for Cancer Research, Oslo University Hospital , Oslo, Norway
| | - Felicia Antohe
- Proteomics Department, Institute of Cellular Biology and Pathology "N. Simionescu" of the Romanian Academy , Bucharest, Romania
| | - Viorel Suica
- Proteomics Department, Institute of Cellular Biology and Pathology "N. Simionescu" of the Romanian Academy , Bucharest, Romania
| | - Guillaume Suarez
- Center for Primary Care and Public Health (Unisanté), University of Lausanne , Lausanne, Switzerland
| | - Ruben t'Kindt
- Research Institute for Chromatography (RIC) , Kortrijk, Belgium
| | - Petra Martin
- Department of Medical Oncology, Midland Regional Hospital Tullamore/St. James's Hospital , Dublin, Ireland
| | - Deborah Penque
- Human Genetics Department, Instituto Nacional De Saúde Dr Ricardo Jorge, Lisboa, Portugal and Centre for Toxicogenomics and Human Health, Universidade Nova De Lisboa , Lisbon,Portugal
| | - Ines Lanca Martins
- Human Genetics Department, Instituto Nacional De Saúde Dr Ricardo Jorge, Lisboa, Portugal and Centre for Toxicogenomics and Human Health, Universidade Nova De Lisboa , Lisbon,Portugal
| | - Ede Bodoki
- Analytical Chemistry Department, Faculty of Pharmacy, "Iuliu Hatieganu" University of Medicine and Pharmacy , Cluj-Napoca, Romania
| | - Bogdan-Cezar Iacob
- Analytical Chemistry Department, Faculty of Pharmacy, "Iuliu Hatieganu" University of Medicine and Pharmacy , Cluj-Napoca, Romania
| | - Eda Aydindogan
- Department of Chemistry, Graduate School of Sciences and Engineering, Koç University , Istanbul, Turkey
| | - Suna Timur
- Institute of Natural Sciences, Department of Biochemistry, Ege University , Izmir, Turkey
| | | | | | - Theo Luider
- Department of Neurology, Erasmus MC , Rotterdam, The Netherlands
| | | | - Marei Sammar
- Ephraim Katzir Department of Biotechnology Engineering, ORT Braude College , Karmiel, Israel
| |
Collapse
|
25
|
Chen X, Xu J, Suo F, Yu C, Zhang D, Chen J, Wu Q, Jing S, Li L, Huang W. A novel naphthofluorescein-based probe for ultrasensitive point-of-care testing of zinc(II) ions and its bioimaging in living cells and zebrafishes. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 229:117949. [PMID: 31864152 DOI: 10.1016/j.saa.2019.117949] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2019] [Revised: 12/10/2019] [Accepted: 12/10/2019] [Indexed: 06/10/2023]
Abstract
The combination of fluorescence method with paper-based diagnostic device is quite suitable in point-of-care testing (POCT). Herein, we designed a novel hybrid fluorescein-based probe ZN-2 and investigated its fluorescent properties thoroughly in the detection of Zn2+. In comparison with the fluorescein-based probe ZN-1, ZN-2 displayed better sensitivity, long-wavelength and faster response to Zn2+ within 20 min. Interestingly, we could achieve ultrasensitive, high-throughput and visual detection in the POCT analysis of Zn2+ by anchoring this probe ZN-2 on the paper-based device. This device with satisfied performance for Zn2+ detection was achieved in real samples including cytochylema, serum and lake water. Finally, the probe ZN-2 was further applied to visualize and monitor the level changes of Zn2+ in the living cells and zebrafishes.
Collapse
Affiliation(s)
- Xingwei Chen
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (Nanjing Tech), 30 South Puzhu Road, Nanjing 211816, PR China
| | - Jiajia Xu
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (Nanjing Tech), 30 South Puzhu Road, Nanjing 211816, PR China
| | - Fengtai Suo
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (Nanjing Tech), 30 South Puzhu Road, Nanjing 211816, PR China
| | - Changmin Yu
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (Nanjing Tech), 30 South Puzhu Road, Nanjing 211816, PR China.
| | - Duoteng Zhang
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (Nanjing Tech), 30 South Puzhu Road, Nanjing 211816, PR China
| | - Jian Chen
- Hunan Provincial Key Laboratory of Controllable Preparation and Functional Application of Fine Polymers, Hunan University of Science and Technology, Xiangtan, Hunan 411201, PR China
| | - Qiong Wu
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (Nanjing Tech), 30 South Puzhu Road, Nanjing 211816, PR China
| | - Su Jing
- School of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211816, PR China.
| | - Lin Li
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (Nanjing Tech), 30 South Puzhu Road, Nanjing 211816, PR China.
| | - Wei Huang
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (Nanjing Tech), 30 South Puzhu Road, Nanjing 211816, PR China; Shaanxi Institute of Flexible Electronics (SIFE), Northwestern Polytechnical University (NPU), 127 West Youyi Road, Xi'an 710072, PR China
| |
Collapse
|
26
|
Xiang W, Lv Q, Shi H, Xie B, Gao L. Aptamer-based biosensor for detecting carcinoembryonic antigen. Talanta 2020; 214:120716. [PMID: 32278406 DOI: 10.1016/j.talanta.2020.120716] [Citation(s) in RCA: 72] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2019] [Revised: 12/30/2019] [Accepted: 01/03/2020] [Indexed: 02/07/2023]
Abstract
Carcinoembryonic antigen (CEA), as one of the common tumor markers, is a human glycoprotein involved in cell adhesion and is expressed during human fetal development. Since the birth of human, CEA expression is largely inhibited, with only low levels in the plasma of healthy adults. Generally, CEA will overexpressed in many cancers, including gastric, breast, ovarian, lung, and pancreatic cancers, especially colorectal cancer. As one of the important tumor markers, the detection of CEA has great significance in differential diagnosis, condition monitoring and therapeutic evaluation of diseases. Conventional CEA testing typically uses immunoassay methods. However, immunoassay methods require complex and expensive instruments and professional personnel to operate. Moreover, radioactive element may cause certain damage to the human body, which limits their wide application. In the past few years, biosensors, especially aptamer-based biosensors, have attracted extensive attention due to their high sensitivity, good selectivity, high accuracy, fast response and low cost. This review briefly classifies and describes the advance in optical and electrochemical aptamer biosensors for CEA detection, also explains and compares their advantages and disadvantages.
Collapse
Affiliation(s)
- Wenwen Xiang
- Institute of Life Sciences, Jiangsu University, Zhenjiang, 212013, PR China
| | - Qiuxiang Lv
- Institute of Life Sciences, Jiangsu University, Zhenjiang, 212013, PR China
| | - Haixia Shi
- P. E. Department of Jiangsu University, Zhenjiang, 212013, PR China
| | - Bing Xie
- Department of Obstetrics and Gynecology, The Fourth People's Hospital of Zhenjiang, Zhenjiang, 212000, PR China
| | - Li Gao
- Institute of Life Sciences, Jiangsu University, Zhenjiang, 212013, PR China.
| |
Collapse
|
27
|
Thiruvengadam M, Venkidasamy B, Subramanian U. Up-converting phosphor technology-based lateral flow assay for quantitative detection of β-hydroxybutyrate in biological samples. Anal Biochem 2019; 591:113546. [PMID: 31863728 DOI: 10.1016/j.ab.2019.113546] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 12/15/2019] [Accepted: 12/15/2019] [Indexed: 11/29/2022]
Abstract
In the present study, a novel up-converting phosphor technology-based lateral flow (UPT-LF) assay was developed as a point of care testing method for the rapid and quantitative detection of β-Hydroxybutyrate (BHB) in milk and serum samples. BHB is one of the most important serum molecular markers not only in ketosis but also for other metabolic disorders in bovines. The developed UPT-LF assay has high sensitivity compared with existing kits in the market for BHB quantification. The detection limit of UPT-BHB- LF assay, with a coefficient of variation (CV) < 10% was 0.01 mM, which is lower than the clinical diagnosis cutoff value of serum BHB (1 mM); while 0.1 mM is the standard level of BHB in milk samples. The relatively good stability and reproducibility of UPT-LF assay with CV<10% results for both serum and milk samples at various storage temperatures demonstrates the superiority of this method and therefore it could be used as a point of care method for the quantitative detection of BHB in the biological samples for veterinary applications. The claimed performance of this assay along with a shorter detection time makes it a viable point-of-care method for the quantitative detection of BHB in the biological samples of veterinary applications.
Collapse
Affiliation(s)
- Muthu Thiruvengadam
- Department of Crop Science, College of Sanghuh Life Science, Konkuk University, Seoul, 05029, Republic of Korea
| | - Baskar Venkidasamy
- Department of Biotechnology, Bharathiar University, Coimbatore, Tamil Nadu, 641 046, India
| | - Umadevi Subramanian
- Translational Research Platform for Veterinary Biologicals, Tamil Nadu Veterinary and Animal Sciences University, Madhavaram Milk Colony, Chennai, 600051, Tamil Nadu, India.
| |
Collapse
|
28
|
Calabretta MM, Álvarez-Diduk R, Michelini E, Roda A, Merkoçi A. Nano-lantern on paper for smartphone-based ATP detection. Biosens Bioelectron 2019; 150:111902. [PMID: 31786021 DOI: 10.1016/j.bios.2019.111902] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 11/12/2019] [Accepted: 11/17/2019] [Indexed: 10/25/2022]
Abstract
ATP-driven bioluminescence relying on the D-luciferin-luciferase reaction is widely employed for several biosensing applications where bacterial ATP detection allows to verify microbial contamination for hygiene monitoring in hospitals, food processing and in general for cell viability studies. Several ATP kit assays are already commercially available but an user-friendly ATP biosensor characterized by low-cost, portability, and adequate sensitivity would be highly valuable for rapid and facile on site screening. Thanks to an innovative freeze-drying procedure, we developed a user-friendly, ready-to-use and stable ATP sensing paper biosensor that can be combined with smartphone detection. The ATP sensing paper includes a lyophilized "nano-lantern" with reaction components being rapidly reconstituted by 10 μL sample addition, enabling detection of 10-14 mol of ATP within 10 min. We analysed urinary microbial ATP as a biomarker of urinary tract infection (UTI), confirming the capability of the ATP sensing paper to detect the threshold for positivity corresponding to 105 colony-forming units of bacteria per mL of urine.
Collapse
Affiliation(s)
- Maria Maddalena Calabretta
- Department of Chemistry "G. Ciamician", University of Bologna, Via Selmi 2, 40126, Bologna, Italy; Nanobioelectronics and Biosensors Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, The Barcelona Institute of Science and Technology, Campus UAB, Bellaterra, 08193, Barcelona, Spain
| | - Ruslan Álvarez-Diduk
- Nanobioelectronics and Biosensors Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, The Barcelona Institute of Science and Technology, Campus UAB, Bellaterra, 08193, Barcelona, Spain
| | - Elisa Michelini
- Department of Chemistry "G. Ciamician", University of Bologna, Via Selmi 2, 40126, Bologna, Italy; INBB, Istituto Nazionale di Biostrutture e Biosistemi, 00136, Rome, Italy; Health Sciences and Technologies-Interdepartmental Center for Industrial Research (HST-ICIR), University of Bologna, via Tolara di Sopra 41/E 40064, Ozzano dell'Emilia, Bologna, Italy.
| | - Aldo Roda
- Department of Chemistry "G. Ciamician", University of Bologna, Via Selmi 2, 40126, Bologna, Italy; INBB, Istituto Nazionale di Biostrutture e Biosistemi, 00136, Rome, Italy.
| | - Arben Merkoçi
- Nanobioelectronics and Biosensors Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, The Barcelona Institute of Science and Technology, Campus UAB, Bellaterra, 08193, Barcelona, Spain; Catalan Institution for Research and Advanced Studies (ICREA), Pg. Lluís Companys 23, 08010, Barcelona, Spain.
| |
Collapse
|
29
|
Suntornsuk W, Suntornsuk L. Recent applications of paper‐based point‐of‐care devices for biomarker detection. Electrophoresis 2019; 41:287-305. [DOI: 10.1002/elps.201900258] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2019] [Revised: 09/30/2019] [Accepted: 10/05/2019] [Indexed: 12/12/2022]
Affiliation(s)
- Worapot Suntornsuk
- Department of Microbiology, Faculty of ScienceKing Mongkut's University of Technology Thonburi Bangkok Thailand
| | - Leena Suntornsuk
- Department of Pharmaceutical ChemistryFaculty of PharmacyMahidol University Bangkok Thailand
| |
Collapse
|
30
|
Chung S, Jennings CM, Yoon J. Distance versus Capillary Flow Dynamics‐Based Detection Methods on a Microfluidic Paper‐Based Analytical Device (μPAD). Chemistry 2019; 25:13070-13077. [DOI: 10.1002/chem.201901514] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Revised: 05/27/2019] [Indexed: 11/12/2022]
Affiliation(s)
- Soo Chung
- Department of Biosystems EngineeringThe University of Arizona Tucson AZ 85721 USA
| | | | - Jeong‐Yeol Yoon
- Department of Biosystems EngineeringThe University of Arizona Tucson AZ 85721 USA
- Department of Biomedical EngineeringThe University of Arizona Tucson AZ 85721 USA
| |
Collapse
|
31
|
Han X, Cao M, Wu M, Wang YJ, Yu C, Zhang C, Yu H, Wei JF, Li L, Huang W. A paper-based chemiluminescence immunoassay device for rapid and high-throughput detection of allergen-specific IgE. Analyst 2019; 144:2584-2593. [PMID: 30830127 DOI: 10.1039/c8an02020e] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The fast and precise detection of potential allergen-specific immunoglobulin E (sIgE) is imperative for the diagnosis and appropriate treatment of allergic diseases. In this study, we have successfully fabricated a novel paper-based immunoassay device for the detection of sIgE in allergic diseases. We used Can f 1, one of the main dog allergens, as a model allergen to detect sIgE in human sera. To achieve excellent performance, the experimental parameters were optimized. Further, we extended this device for potential applications in the clinical diagnosis of allergic diseases: worthwhile clinical performance in the detection of allergens was achieved as compared to that achieved by commercial enzyme-linked immunosorbent assay (ELISA) kit. Therefore, it was proven that this strategy has the advantages of high-throughput, rapid, sensitive, and highly accurate detection of trace amounts of sIgEs. Furthermore, by simply changing the antigen and antibody, this device could be used for the high-throughput detection of other allergens, so as to achieve multiallergen detection and appropriate desensitization therapy, thereby making it promising in the determination of allergic diseases in clinics.
Collapse
Affiliation(s)
- Xisi Han
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211800, P. R. China.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Guo X, Zong L, Jiao Y, Han Y, Zhang X, Xu J, Li L, Zhang CW, Liu Z, Ju Q, Liu J, Xu Z, Yu HD, Huang W. Signal-Enhanced Detection of Multiplexed Cardiac Biomarkers by a Paper-Based Fluorogenic Immunodevice Integrated with Zinc Oxide Nanowires. Anal Chem 2019; 91:9300-9307. [PMID: 31241314 DOI: 10.1021/acs.analchem.9b02557] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Using a single test to comprehensively evaluate multiple cardiac biomarkers for early diagnosis and prevention of acute myocardial infarction (AMI) has faced enormous challenges. Here, we have developed paper-based fluorogenic immunodevices for multiplexed detection of three cardiac biomarkers, namely, human heart-type fatty acid binding protein (FABP), cardiac troponin I (cTnI), and myoglobin, simultaneously. The detection is based on a strategy using zinc oxide nanowires (ZnO NWs) to enhance fluorescence signals (∼5-fold compared to that on pure paper). The immunodevices showed high sensitivity and selectivity for FABP, cTnI, and myoglobin with detection limits of 1.36 ng/mL, 1.00 ng/mL, and 2.38 ng/mL, respectively. Additionally, the paper-based immunoassay was rapid (∼5 min to complete the test) and portable (using a homemade chamber with a smartphone and an ultraviolet lamp). The developed devices integrated with ZnO NWs enable quantitative, sensitive, and simultaneous detection of multiple cardiac biomarkers in point-of-care settings, which provides a useful approach for monitoring AMI diseases and may be extended to other medical diagnostics and environmental assessments.
Collapse
Affiliation(s)
- Xueying Guo
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China
| | - Lijun Zong
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China
| | - Yucui Jiao
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China
| | - Yufeng Han
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China
| | - Xiaopan Zhang
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China
| | - Jia Xu
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China
| | - Lin Li
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China
| | - Cheng-Wu Zhang
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China
| | - Zhipeng Liu
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China
| | - Qiang Ju
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China
| | - Jinhua Liu
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China
| | - Zhihui Xu
- Department of Cardiology , The First Affiliated Hospital of Nanjing Medical University , 300 Guangzhou Road , Nanjing 210029 , P.R. China
| | - Hai-Dong Yu
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China.,Xi'an Institute of Flexible Electronics , Northwestern Polytechnical University , 127 West Youyi Road , Xi'an 710072 , P.R. China
| | - Wei Huang
- Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM) , Nanjing Tech University (NanjingTech) , 30 South Puzhu Road , Nanjing 211816 , P.R. China.,Xi'an Institute of Flexible Electronics , Northwestern Polytechnical University , 127 West Youyi Road , Xi'an 710072 , P.R. China
| |
Collapse
|
33
|
Abstract
Specific nucleic acid detection in vitro or in vivo has become increasingly important in the discovery of genetic diseases, diagnosing pathogen infection and monitoring disease treatment. One challenge, however, is that the amount of target nucleic acid in specimens is limited. Furthermore, direct sensing methods are also unable to provide sufficient sensitivity and specificity. Fortunately, due to advances in nanotechnology and nanomaterials, nanotechnology-based bioassays have emerged as powerful and promising approaches providing ultra-high sensitivity and specificity in nucleic acid detection. This chapter presents an overview of strategies used in the development and integration of nanotechnology for nucleic acid detection, including optical and electrical detection methods, and nucleic acid assistant recycling amplification strategies. Recent 5 years representative examples are reviewed to demonstrate the proof-of-concept with promising applications for DNA/RNA detection and the underlying mechanism for detection of DNA/RNA with the higher sensitivity and selectivity. Furthermore, a brief discussion of common unresolved issues and future trends in this field is provided both from fundamental and practical point of view.
Collapse
Affiliation(s)
- Hong Zhou
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, College of Chemistry and Chemical Engineering, Linyi University, Linyi, China
| | - Jing Liu
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, College of Chemistry and Chemical Engineering, Linyi University, Linyi, China
| | - Jing-Juan Xu
- Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, China.
| | - Shusheng Zhang
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, College of Chemistry and Chemical Engineering, Linyi University, Linyi, China.
| | - Hong-Yuan Chen
- Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, China
| |
Collapse
|
34
|
Sun J, Zhang X, Li T, Xie J, Shao B, Xue D, Tang X, Li H, Liu Y. Ultrasensitive On-Site Detection of Biological Active Ricin in Complex Food Matrices Based on Immunomagnetic Enrichment and Fluorescence Switch-On Nanoprobe. Anal Chem 2019; 91:6454-6461. [PMID: 30994324 DOI: 10.1021/acs.analchem.8b04458] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Ricin is a highly toxic protein largely existing in castor beans, which could be used as a warfare agent due to its unique properties. As a deadenylase, inactivation of ricin means a loss of its toxic threat. Therefore, developing simple, accurate, and sensitive on-site detection of biologically active ricin in wide types of complex matrices is most valuable. Here, antifouling polymer brush modified magnetic beads were prepared first and post modified with ricin monoclonal antibody (the MB@P(C-H)-mAbricin) to efficiently capture ricin from various foods and biological matrices. Active ricin obtained in this manner were sequentially determined by a new designed AuNP/QDs nanoassembly. In this double strand oligodeoxynucleotides (dsODN) linked core-satellite nanoprobe, the fluorescence of satellite QDs was extensively quenched by AuNPs due to the dipole-metal interaction. Active ricin can react with its specific depurination substrates which had been inserted in the dsODN linkers. This reaction would trigger the separation of QDs from Au cores by cutting multiple adenines, and then result in the restoration of QDs fluorescence. By coupling with the magnetic enrichment, this AuNP/QDs nanoprobe provided a qualitative result for active ricin in the range from 10.0 to 100.0 ng mL-1 with the limit of detection as low as 7.46 ng mL-1. Compared with previously proposed methods, this on-site detection strategy offered an easy to handle on-site test for trace amounts of active ricin in a wide range of complex matrices.
Collapse
Affiliation(s)
- Jiefang Sun
- Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning , Beijing Center for Disease Prevention and Control , Beijing 100013 , P. R. China
| | - Xueyong Zhang
- School of Police Law Enforcement Abilities Training , People's Public Security University of China , Beijing 100038 , P. R. China
| | - Ting Li
- School of Public Health , Capital Medical University , Beijing 100069 , P. R. China
| | - Jijia Xie
- Department of Chemical Engineering , University College London , Torrington Place , London WC1E7JE , United Kingdom
| | - Bing Shao
- Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning , Beijing Center for Disease Prevention and Control , Beijing 100013 , P. R. China.,Beijing Advanced Innovation Center for Food Nutrition and Human Health , China Agricultural University , Beijing 100193 , P. R. China
| | - Dingshuai Xue
- State Key Laboratory of Lithospheric Evolution, Institute of Geology and Geophysics , Chinese Academy of Sciences , Beijing 100029 , P. R. China
| | - Xu Tang
- State Key Laboratory of Lithospheric Evolution, Institute of Geology and Geophysics , Chinese Academy of Sciences , Beijing 100029 , P. R. China
| | - Hui Li
- Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning , Beijing Center for Disease Prevention and Control , Beijing 100013 , P. R. China
| | - Yanhong Liu
- State Key Laboratory of Lithospheric Evolution, Institute of Geology and Geophysics , Chinese Academy of Sciences , Beijing 100029 , P. R. China
| |
Collapse
|
35
|
Zong L, Jiao Y, Guo X, Zhu C, Gao L, Han Y, Li L, Zhang C, Liu Z, Liu J, Ju Q, Yu HD, Huang W. Paper-based fluorescent immunoassay for highly sensitive and selective detection of norfloxacin in milk at picogram level. Talanta 2019; 195:333-338. [DOI: 10.1016/j.talanta.2018.11.073] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 11/15/2018] [Accepted: 11/22/2018] [Indexed: 12/16/2022]
|
36
|
Wu M, Suo F, Zhou J, Gong Q, Bai L, Chen B, Wu Q, Zhang C, Yu H, Huang X, Li L, Huang W. Paper-Based Fluorogenic Device for Detection of Copper Ions in a Biological System. ACS APPLIED BIO MATERIALS 2018; 1:1523-1529. [DOI: 10.1021/acsabm.8b00435] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Meirong Wu
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
| | - Fengtai Suo
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
| | - Jia Zhou
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
| | - Qiuyu Gong
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
| | - Lei Bai
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
| | - Buxiang Chen
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
| | - Qiong Wu
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
| | - Chengwu Zhang
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
| | - Haidong Yu
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
| | - Xiao Huang
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
| | - Lin Li
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
| | - Wei Huang
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing, 211816, People’s Republic of China
- Shanxi Institute of Flexible Electronics (SIFE), Northwestern Polytechnical University (NPU), 127 West Youyi Road, Xi’an 710072, People’s Republic of China
| |
Collapse
|
37
|
Bai L, Wu M, Chen B, Ding Y, Zhou J, Ge J, Zhang C, Fu Z, Li L, Huang W. Membrane-Targetable Probes for Hg2+Detection in Live Cells and Paper-Based Devices. ChemistrySelect 2018. [DOI: 10.1002/slct.201801619] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Lei Bai
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM); Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM); Nanjing Tech University (NanjingTech); Nanjing 211816 China
| | - Meirong Wu
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM); Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM); Nanjing Tech University (NanjingTech); Nanjing 211816 China
| | - Buxiang Chen
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM); Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM); Nanjing Tech University (NanjingTech); Nanjing 211816 China
| | - Yaqi Ding
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM); Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM); Nanjing Tech University (NanjingTech); Nanjing 211816 China
| | - Jia Zhou
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM); Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM); Nanjing Tech University (NanjingTech); Nanjing 211816 China
| | - Jingyan Ge
- Key Laboratory of Bioorganic Synthesis of Zhejiang Province; College of Biotechnology and Bioengineering; Zhejiang University of Technology, Hangzhou; 310014, P. R. China
| | - Chengwu Zhang
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM); Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM); Nanjing Tech University (NanjingTech); Nanjing 211816 China
| | - Zhenqian Fu
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM); Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM); Nanjing Tech University (NanjingTech); Nanjing 211816 China
| | - Lin Li
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM); Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM); Nanjing Tech University (NanjingTech); Nanjing 211816 China
| | - Wei Huang
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM); Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM); Nanjing Tech University (NanjingTech); Nanjing 211816 China
- Shaanxi Institute of Flexible Electronics (SIFE); Northwestern Polytechnical University; 127 West Youyi Road Xi'an 710072, P. R
| |
Collapse
|
38
|
Singh AT, Lantigua D, Meka A, Taing S, Pandher M, Camci-Unal G. Paper-Based Sensors: Emerging Themes and Applications. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2838. [PMID: 30154323 PMCID: PMC6164297 DOI: 10.3390/s18092838] [Citation(s) in RCA: 118] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/10/2018] [Revised: 08/21/2018] [Accepted: 08/23/2018] [Indexed: 02/06/2023]
Abstract
Paper is a versatile, flexible, porous, and eco-friendly substrate that is utilized in the fabrication of low-cost devices and biosensors for rapid detection of analytes of interest. Paper-based sensors provide affordable platforms for simple, accurate, and rapid detection of diseases, in addition to monitoring food quality, environmental and sun exposure, and detection of pathogens. Paper-based devices provide an inexpensive technology for fabrication of simple and portable diagnostic systems that can be immensely useful in resource-limited settings, such as in developing countries or austere environments, where fully-equipped facilities and highly trained medical staff are absent. In this work, we present the different types of paper that are currently utilized in fabrication of paper-based sensors, and common fabrication techniques ranging from wax printing to origami- and kirigami-based approaches. In addition, we present different detection techniques that are employed in paper-based sensors such as colorimetric, electrochemical, and fluorescence detection, chemiluminescence, and electrochemiluminescence, as well as their applications including disease diagnostics, cell cultures, monitoring sun exposure, and analysis of environmental reagents including pollutants. Furthermore, main advantages and disadvantages of different types of paper and future trends for paper-based sensors are discussed.
Collapse
Affiliation(s)
- Amrita Tribhuwan Singh
- Department of Biological Sciences, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, USA.
- Department of Chemical Engineering, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, USA.
| | - Darlin Lantigua
- Department of Chemical Engineering, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, USA.
- Biomedical Engineering and Biotechnology Program, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, USA.
| | - Akhil Meka
- Department of Biological Sciences, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, USA.
- Department of Chemical Engineering, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, USA.
| | - Shainlee Taing
- Department of Biological Sciences, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, USA.
- Department of Chemical Engineering, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, USA.
| | - Manjot Pandher
- Department of Chemical Engineering, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, USA.
- Biomedical Engineering and Biotechnology Program, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, USA.
| | - Gulden Camci-Unal
- Department of Chemical Engineering, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854, USA.
| |
Collapse
|
39
|
Ulep TH, Yoon JY. Challenges in paper-based fluorogenic optical sensing with smartphones. NANO CONVERGENCE 2018; 5:14. [PMID: 29755926 PMCID: PMC5937860 DOI: 10.1186/s40580-018-0146-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Accepted: 04/27/2018] [Indexed: 05/23/2023]
Abstract
Application of optically superior, tunable fluorescent nanotechnologies have long been demonstrated throughout many chemical and biological sensing applications. Combined with microfluidics technologies, i.e. on lab-on-a-chip platforms, such fluorescent nanotechnologies have often enabled extreme sensitivity, sometimes down to single molecule level. Within recent years there has been a peak interest in translating fluorescent nanotechnology onto paper-based platforms for chemical and biological sensing, as a simple, low-cost, disposable alternative to conventional silicone-based microfluidic substrates. On the other hand, smartphone integration as an optical detection system as well as user interface and data processing component has been widely attempted, serving as a gateway to on-board quantitative processing, enhanced mobility, and interconnectivity with informational networks. Smartphone sensing can be integrated to these paper-based fluorogenic assays towards demonstrating extreme sensitivity as well as ease-of-use and low-cost. However, with these emerging technologies there are always technical limitations that must be addressed; for example, paper's autofluorescence that perturbs fluorogenic sensing; smartphone flash's limitations in fluorescent excitation; smartphone camera's limitations in detecting narrow-band fluorescent emission, etc. In this review, physical optical setups, digital enhancement algorithms, and various fluorescent measurement techniques are discussed and pinpointed as areas of opportunities to further improve paper-based fluorogenic optical sensing with smartphones.
Collapse
Affiliation(s)
- Tiffany-Heather Ulep
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721 USA
| | - Jeong-Yeol Yoon
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721 USA
| |
Collapse
|