1
|
Qin X, Zhu X, Wang Y. Fouling-Free electrochemical strategy based on vertically-aligned peptide layer for cardiac troponin I sensitive detection in human serum. Anal Chim Acta 2024; 1317:342866. [PMID: 39030026 DOI: 10.1016/j.aca.2024.342866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 05/24/2024] [Accepted: 06/10/2024] [Indexed: 07/21/2024]
Abstract
BACKGROUND Cardiac troponin I (CTnI) is demonstrated as one of the most promising disease biomarkers for early diagnosing acute myocardial infarction (AMI). To date, electrochemical immunosensors have been extensively studied in the field of cTnI determination. But highly accurate and sensitive cTnI detection by this method is still a challenge due to non-specific adsorption on electrode interfaces in complex human serum. As a result, it is necessary to develop an antifouling electrochemical immunosensor with high sensitivity for the detection of cTnI. RESULTS In this work, an antifouling electrochemical immunosensor was constructed based on vertically-aligned peptide layer consisting of Au nanoparticles (AuNPs) and amphiphilic CEAK16 peptide (CEAK16@AuNPs) for sensitive and accurate detection of cTnI in human serum. The vertically-aligned CEAK16@AuNPs interface provided a stable hydration layer originated from attraction of water molecules by amino acids on the hydrophilic side of the CEAK16, which effectively reduced non-specific adsorption and enhanced electron transfer rate. The cTnI immunosensor possessed great analytical performance with a wide range from 1 fg mL-1 to 1 μg mL-1 and a low detection limit of 0.28 fg mL-1 (S/N = 3). Additionally, the proposed CEAK16@AuNPs sensing interface showed excellent long-term antifouling performance and electrochemical activity that preserved 80 % of the initial signal after 20-days exposure in human serum samples. Consequently, the cTnI immunosensor displayed excellent detection accuracy compared to clinical methods and owned good selectivity, stability and reproducibility. SIGNIFICANCE The development of this strategy provides a versatile tool for accurate quantitative cTnI analysis in real human serum, thus helping to achieve early AMI diagnosis effectively and holding the promising potentials for other immunosensor in disease diagnosis.
Collapse
Affiliation(s)
- Xingao Qin
- State Key Laboratory of Pollution Control and Resources Reuse (Tongji University), College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, 200092, China
| | - Xiaoyu Zhu
- State Key Laboratory of Pollution Control and Resources Reuse (Tongji University), College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, 200092, China
| | - Ying Wang
- State Key Laboratory of Pollution Control and Resources Reuse (Tongji University), College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, 200092, China.
| |
Collapse
|
2
|
Ouyang R, Feng M, Liu J, Wang C, Wang Z, Hu X, Miao Y, Zhou S. Hydrangea-like TiO 2/Bi 2MoO 6 porous nanoflowers triggering highly sensitive electrochemical immunosensing to tumor marker. Mikrochim Acta 2024; 191:262. [PMID: 38613581 DOI: 10.1007/s00604-024-06346-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Accepted: 04/04/2024] [Indexed: 04/15/2024]
Abstract
Rapid and sensitive detection of carcinoembryonic antigen (CEA) is of great significance for cancer patients. Here, molybdenum (Mo) was doped into bismuth oxide (Bi2O3) by one-pot hydrothermal method forming porous tremella Bi2MoO6 nanocomposites with a larger specific surface area than the spherical structure. Then, a new kind of hydrangea-like TiO2/Bi2MoO6 porous nanoflowers (NFs) was prepared by doping titanium into Bi2MoO6, where titanium dioxide (TiO2) grew in situ on the surface of Bi2MoO6 nanoparticles (NPs). The hydrangea-like structure provides larger specific surface area, higher electron transfer ability and biocompatibility as well as more active sites conducive to the attachment of anti-carcinoembryonic antigen (anti-CEA) to TiO2/Bi2MoO6 NFs. A novel label-free electrochemical immunosensor was then constructed for the quantitative detection of CEA using TiO2/Bi2MoO6 NFs as sensing platform, showing a good linear relationship with CEA in the concentration range 1.0 pg/mL ~ 1.0 mg/mL and a detection limit of 0.125 pg/mL (S/N = 3). The results achieved with the designed immunosensor are comparable with many existing immunosensors used for the detection of CEA in real samples.
Collapse
Affiliation(s)
- Ruizhuo Ouyang
- Institute of Bismuth Science & School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Meina Feng
- Institute of Bismuth Science & School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Jinyao Liu
- Institute of Bismuth Science & School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Caihong Wang
- Institute of Bismuth Science & School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Zhongmin Wang
- Institute of Bismuth Science & School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Xin Hu
- Zhejiang Zhili Environmental Protection Technology, Jinhua, 321000, China
| | - Yuqing Miao
- Institute of Bismuth Science & School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Shuang Zhou
- Cancer Institute, Tongji University School of Medicine, Shanghai, 200092, China.
| |
Collapse
|
3
|
Ren X, Wu F, Wu M, Gao H, Wu C, Mu W, Liu S, Que L, Zhang H, Miao M, Chang D, Pan H. Sandwich-type immunosensor based on aminated 3D-rGOF-NH 2 and CMK-3-Fc-MgAl-LDH multilayer nanocomposites for detection of CA125. Bioelectrochemistry 2024; 156:108613. [PMID: 37995504 DOI: 10.1016/j.bioelechem.2023.108613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Revised: 11/15/2023] [Accepted: 11/16/2023] [Indexed: 11/25/2023]
Abstract
Cancer antigen 125 (CA125)1 is the most important biological screening indicator used to monitor epithelial ovarian cancers, and it plays a vital role in distinguishing ovarian cancers from benign diseases. Biosensors show great potential in the analysis and detection of disease markers. In this study, we designed electrochemical sensors based on three-dimensional amino-functionalized reduced graphene oxide (3D-rGOF-NH2),2 MgAl layered double hydroxide nanocomposites containing ordered mesoporous carbon (CMK-3),3 and ferrocene carboxylic acids(Fc-COOH)4for the detection of CA125. 3D-rGOF-NH2 possesses good conductivity, a large surface area, and high porosity, enabling more immobilized nanoparticles to be deposited on its surface with excellent stability. CMK-3@Fc@MgAl-LDH nanocomposite was used as a carrier to enhance the immobilization of antibodies and the loading of Fc, conductors to enhance conductivity, and enhancers to gradually amplify the signal of Fc. The surface morphology, elemental composition, and surface groups of the materials were characterized using scanning electron microscopy (SEM),5 transmission electron microscopy (TEM),6 and X-ray diffraction (XRD)7 techniques. The response signal of the electrochemical sensor was measured by DPV. Under the optimal conditions, the electrochemical sensor obtained a linear detection range of 0.01 U/mL-100 U/mL with a detection limit of 0.00417 U/mL.
Collapse
Affiliation(s)
- Xinshui Ren
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; Shanghai University of Medicine and Health Sciences, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Fangfang Wu
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Mengdie Wu
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; Shanghai University of Medicine and Health Sciences, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Hongmin Gao
- School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Chunyan Wu
- School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Wendi Mu
- School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Simin Liu
- School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Longbin Que
- School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Hehua Zhang
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Meng Miao
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
| | - Dong Chang
- Department of Laboratory Medicine, Shanghai Pudong Hospital, Shanghai 201399, China.
| | - Hongzhi Pan
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; The Affiliated Zhoupu Hospital, Shanghai University of Medicine & Health Sciences, Shanghai 201318, China.
| |
Collapse
|
4
|
Ben Moussa F, Kutner W, Beduk T, Sena-Torralba A, Mostafavi E. Electrochemical bio- and chemosensors for cancer biomarkers: Natural (with antibodies) versus biomimicking artificial (with aptamers and molecularly imprinted polymers) recognition. Talanta 2024; 267:125259. [PMID: 37806110 DOI: 10.1016/j.talanta.2023.125259] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 09/29/2023] [Accepted: 09/30/2023] [Indexed: 10/10/2023]
Abstract
Electrochemical (EC) bio- and chemosensors are highly promising for on-chip and point-of-care testing (POST) devices. They can make a breakthrough in early cancer diagnosis. Most current EC sensors for cancer biomarkers' detection and determination use natural antibodies as recognition units. However, those quickly lose their biorecognition ability upon exposure to harsh environments, comprising extreme pH, humidity, temperature, etc. So-called "plastic antibodies," including aptamers and molecularly imprinted polymers (MIPs), are hypothesized to be a smart alternative to antibodies. They have attracted the interest of the sensor research community, offering a low cost-to-performance ratio with high stability, an essential advantage toward their commercialization. Herein, we critically review recent technological advances in devising and fabricating EC bio- and chemosensors for cancer biomarkers, classifying them according to the type of recognition unit used into three categories, i.e., antibody-, aptamer-, and MIP-based EC sensors for cancer biomarkers. Each sensor fabrication strategy has been discussed, from the devising concept to cancer sensing applications, including using different innovative nanomaterials and signal transduction strategies. Moreover, employing each recognition unit in the EC sensing of cancer biomarkers has been critically compared in detail to enlighten each recognition unit's advantages, effectiveness, and limitations.
Collapse
Affiliation(s)
- Fatah Ben Moussa
- Process Engineering Laboratory, Applied Sciences Faculty, Kasdi Merbah University, Ouargla, 30000, Algeria.
| | - Wlodzimierz Kutner
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224, Warsaw, Poland; Faculty of Mathematics and Natural Sciences. School of Sciences, Cardinal Stefan Wyszynski University in Warsaw, Wo ycickiego 1/3, 01-815, Warsaw, Poland
| | - Tutku Beduk
- Silicon Austria Labs GmbH: Sensor Systems, Europastrasse 12, 9524, Villach, Austria
| | - Amadeo Sena-Torralba
- Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, 46022, Valencia, Spain
| | - Ebrahim Mostafavi
- Department of Medicine, Stanford University School of Medicine, Stanford, CA, 94305, USA; Stanford Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA, 94305, USA
| |
Collapse
|
5
|
Kiio LK, Onyatta JO, Ndangili PM, Oloo F, Santamaria C, Montuenga LM, Mbui DN. Ultrasensitive immunosensor for multiplex detection of cancer biomarkers carcinoembryonic antigen (CEA) and yamaguchi sarcoma viral oncogene homolog 1 (YES1) based on eco-friendly synthesized gold nanoparticles. Talanta 2024; 266:124934. [PMID: 37454512 DOI: 10.1016/j.talanta.2023.124934] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 06/30/2023] [Accepted: 07/10/2023] [Indexed: 07/18/2023]
Abstract
Cancer is one of the most extensive diseases with the highest mortality rate, accounting for almost 10 million deaths in 2020. The most common cancers are breast, lung, colon and rectum and prostate cancers. Of these, lung cancer, accounted for about 1.8 million of all cancer deaths (25%) in 2020. Detection of cancer relies on presence of biomarkers such as DNA molecules, proteins and metabolites released by cancerous cells into the circulation. Carcinoembryonic antigen (CEA) is one of the biomarkers that has been used for the detection of lung cancer. However, CEA is not specific to lung cancer since it is also manifested in gastric cancer, pancreatic cancer, colorectal cancer, and breast cancer. Recently, v-YES1 Yamaguchi sarcoma viral oncogene homolog 1 (YES1) was described as a specific biomarker for lung cancer. The detection of both CEA and YES1 would give more precise and authentic information for detecting lung cancer. This is because detection of a single tumor marker usually limits the precision in tumor diagnosis, due to the fact that several cancers have more than one marker linked with their prevalence. Whereas traditional methods have been used for the detection of CEA, electrochemical immunosensors have attracted considerable attention owing to their profound advantages, including fast response, miniaturization, high selectivity, low sample requirements and magnificent sensitivity. The fabrication of a multiplex and simultaneous immunosensor is met with challenge of preparation of distinguishable immunoprobes with different redox activities. This can be addressed by incorporation of electroactive Nano metals into the sensing platform. In this study, gold nanoparticles were used for the fabrication of an ultrasensitive sandwich electrochemical multiplex immunosensor for simultaneous detection of CEA and YES1. Under optimized conditions, the electrochemical immunosensor detection limit for YES1 and CEA was found to be 0.0022 and 0.0034 ng/mL respectively within a linear range of 0.1-50 ng/mL. The proposed immunosensor proved to be stable for up to 2 weeks and had negligible cross reactivity towards various interfering compounds in human plasma. This study reports that gold nanoparticles can be bio synthesized using shade dried Mangifera indica leaves extract. The bio-synthesized gold nanoparticles coupled with thiolated protein G can be used for fabrication of a multiplex immunosensor for detection of CEA and YES1. The proposed immunosensor can provide a new approach for early diagnosis of circulating cancer biomarkers and holds great promise for application in clinical diagnosis.
Collapse
Affiliation(s)
- Lucia K Kiio
- Program in Solid Tumors, Centro de Investigación Médica Aplicada (CIMA), University of Navarra, 31008, Pamplona, Spain; Department of Chemistry, University of Nairobi, 30197-00100, Nairobi, Kenya; School of Chemistry and Material Science, The Technical University of Kenya, 52428-00200, Nairobi, Kenya.
| | - John O Onyatta
- Department of Chemistry, University of Nairobi, 30197-00100, Nairobi, Kenya.
| | - Peter M Ndangili
- School of Chemistry and Material Science, The Technical University of Kenya, 52428-00200, Nairobi, Kenya.
| | - Florence Oloo
- School of Chemistry and Material Science, The Technical University of Kenya, 52428-00200, Nairobi, Kenya.
| | - Carolina Santamaria
- BIOMA Center, Department of Chemistry, School of Sciences University of Navarra, 31008, Pamplona, Spain.
| | - Luis M Montuenga
- Program in Solid Tumors, Centro de Investigación Médica Aplicada (CIMA), University of Navarra, 31008, Pamplona, Spain; Department of Pathology, Anatomy and Physiology, School of Medicine, University of Navarra, Pamplona, Spain; Consorcio de Investigación Biomédica en Red de Cáncer (CIBERONC), Madrid, Spain; Navarra Health Research Institute (IDISNA), Pamplona, Spain.
| | - Damaris N Mbui
- Department of Chemistry, University of Nairobi, 30197-00100, Nairobi, Kenya.
| |
Collapse
|
6
|
Ranjbari S, Hatamluyi B, Aghaee-Bakhtiari SH, Rezayi M, Arefinia R. A label-free electrochemical biosensor based on PBA-Au-MXene QD for miR-122 detection in serum samples. Mikrochim Acta 2023; 190:482. [PMID: 37999813 DOI: 10.1007/s00604-023-06062-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 10/19/2023] [Indexed: 11/25/2023]
Abstract
A poly(n-butyl acrylate)-gold-MXene quantum dots (PBA-Au-MXene QD) nanocomposite-based biosensor is presented that is modified by unique antisense single-stranded DNA (ssDNA) and uses the electrochemical detection methods of DPV, CV, and EIS to early detect miR-122 as a breast cancer biomarker in real clinical samples. This fabrication method is based on advanced nanotechnology, at which a poly(n-butyl acrylate) (PBA) as a non-conductive polymer transforms into a conductive composite by incorporating Au-MXene QD. This biosensor had a limit of detection (LOD) of 0.8 zM and a linear range from 0.001 aM to 1000 nM, making it capable of detecting the low concentrations of miR-122 in patient samples. Moreover, it allows approximately 100% sensitivity and 100% specificity for miR-122 without extraction. The synthesis and detection characteristics were evaluated by different complementary tests such as AFM, FTIR, TEM, and FESEM. This new biosensor can have a high potential in clinical applications to detect breast cancer early and hence improve patient outcomes.
Collapse
Affiliation(s)
- Sara Ranjbari
- Chemical Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
| | - Behnaz Hatamluyi
- Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Seyed Hamid Aghaee-Bakhtiari
- Department of Medical Biotechnology and Nanotechnology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Majid Rezayi
- Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Department of Medical Biotechnology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Reza Arefinia
- Chemical Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Iran.
| |
Collapse
|
7
|
Chen DN, Wang AJ, Feng JJ, Cheang TY. One-pot wet-chemical fabrication of 3D urchin-like core-shell Au@PdCu nanocrystals for electrochemical breast cancer immunoassay. Mikrochim Acta 2023; 190:353. [PMID: 37581740 DOI: 10.1007/s00604-023-05932-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 07/25/2023] [Indexed: 08/16/2023]
Abstract
Carbohydrate antigen 15-3 (CA15-3) is an important biomarker for early diagnosis of breast cancer. Herein, a label-free electrochemical immunosensor was built based on three-dimensional (3D) urchin-like core-shell Au@PdCu nanocrystals (labeled Au@PdCu NCs) for highly sensitive detection of CA15-3, where K3[Fe(CN)6] behaved as an electroactive probe. The Au@PdCu NCs were synthesized by a simple one-pot wet-chemical approach and the morphology, structures, and electrocatalytic property were investigated by several techniques. The Au@PdCu NCs prepared worked as electrode material to anchor more antibodies and as signal magnification material by virtue of its exceptional catalytic property. The developed biosensor exhibited a wide linear detection range from 0.1 to 300 U mL-1 and a low limit of detection (0.011 U mL-1, S/N = 3) for determination of CA15-3 under the optimal conditions. The established biosensing platform exhibits some insights for detecting other tumor biomarkers in clinical assays and early diagnosis.
Collapse
Affiliation(s)
- Di-Nan Chen
- Department of Breast Care Centre, the First Affiliated Hospital of Guangdong Pharmaceutical University, Guangzhou, 510080, China
- College of Chemistry and Materials Science, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua, 321004, China
| | - Ai-Jun Wang
- College of Chemistry and Materials Science, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua, 321004, China
| | - Jiu-Ju Feng
- Department of Breast Care Centre, the First Affiliated Hospital of Guangdong Pharmaceutical University, Guangzhou, 510080, China.
| | - Tuck Yun Cheang
- Department of Breast Care Centre, the First Affiliated Hospital of Guangdong Pharmaceutical University, Guangzhou, 510080, China.
| |
Collapse
|
8
|
Sun HN, Mou LL, Tan YY, Liu M, Li SS. Facile preparation of Ru nanoassemblies for electrochemical immunoassay of carcinoembryonic antigen in clinical serum. Anal Biochem 2023:115234. [PMID: 37422060 DOI: 10.1016/j.ab.2023.115234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 06/21/2023] [Accepted: 07/04/2023] [Indexed: 07/10/2023]
Abstract
Abnormal expression of carcinoembryonic antigen (CEA) can be used for early diagnosis of various cancers (e.g. colorectal cancer, cervical carcinomas, and breast cancer). In this work, using l-cysteine-ferrocene-Ruthenium nanocomposites (L-Cys-Fc-Ru) to immobilize secondary antibody (Ab2) and Au nanoparticles (NPs) as the substrate to ensure accurate capture of primary antibody (Ab1), a signal-on sandwich-like biosensor was constructed in the presence of CEA. Specifically, Ru nanoassemblies (NAs) were first prepared by a facile one-step solvothermal approach as signal amplifiers for the electrical signal of Fc. Based on specific immune recognition, as the increase of CEA concentration, the content of L-Cys-Fc-Ru-Ab2 captured on the electrode surface also increased, thus the signal of Fc gradually increased. Therefore, the quantitative detection of CEA can be realized according to the peak current of Fc. After a series of experiments, it was found that the biosensor has a wide detection range from 1.0 pg mL-1 to 100.0 ng mL-1 and a low detection limit down to 0.5 pg mL-1, as well as good selectivity, repeatability and stability. Furthermore, satisfactory results were also obtained for the determination of CEA in serums, which were comparable to commercial electrochemiluminescence (ECL) method. The developed biosensor shows great potential in clinical applications.
Collapse
Affiliation(s)
- He-Nan Sun
- Institute for Chemical Biology & Biosensing, College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao, 266071, China
| | - Li-Li Mou
- College of Big Data, Haidu College Qingdao Agricultural University, 11 Wenhua Road, Laiyang, 265200, China
| | - Yuan-Yuan Tan
- Institute for Chemical Biology & Biosensing, College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao, 266071, China
| | - Mingjun Liu
- Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, 16 Jiangsu Road, Qingdao, 266003, China
| | - Shan-Shan Li
- Institute for Chemical Biology & Biosensing, College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao, 266071, China.
| |
Collapse
|
9
|
Song G, Han H, Ma Z. Anti-Fouling Strategies of Electrochemical Sensors for Tumor Markers. SENSORS (BASEL, SWITZERLAND) 2023; 23:5202. [PMID: 37299929 PMCID: PMC10256055 DOI: 10.3390/s23115202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 05/26/2023] [Accepted: 05/27/2023] [Indexed: 06/12/2023]
Abstract
The early detection and prognosis of cancers require sensitive and accurate detection methods; with developments in medicine, electrochemical biosensors have been developed that can meet these clinical needs. However, the composition of biological samples represented by serum is complex; when substances undergo non-specific adsorption to an electrode and cause fouling, the sensitivity and accuracy of the electrochemical sensor are affected. In order to reduce the effects of fouling on electrochemical sensors, a variety of anti-fouling materials and methods have been developed, and enormous progress has been made over the past few decades. Herein, the recent advances in anti-fouling materials and strategies for using electrochemical sensors for tumor markers are reviewed; we focus on new anti-fouling methods that separate the immunorecognition and signal readout platforms.
Collapse
Affiliation(s)
| | - Hongliang Han
- Department of Chemistry, Capital Normal University, Beijing 100048, China;
| | - Zhanfang Ma
- Department of Chemistry, Capital Normal University, Beijing 100048, China;
| |
Collapse
|
10
|
Chen H, Zhang J, Huang R, Wang D, Deng D, Zhang Q, Luo L. The Applications of Electrochemical Immunosensors in the Detection of Disease Biomarkers: A Review. Molecules 2023; 28:molecules28083605. [PMID: 37110837 PMCID: PMC10144570 DOI: 10.3390/molecules28083605] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2023] [Revised: 04/18/2023] [Accepted: 04/19/2023] [Indexed: 04/29/2023] Open
Abstract
Disease-related biomarkers may serve as indicators of human disease. The clinical diagnosis of diseases may largely benefit from timely and accurate detection of biomarkers, which has been the subject of extensive investigations. Due to the specificity of antibody and antigen recognition, electrochemical immunosensors can accurately detect multiple disease biomarkers, including proteins, antigens, and enzymes. This review deals with the fundamentals and types of electrochemical immunosensors. The electrochemical immunosensors are developed using three different catalysts: redox couples, typical biological enzymes, and nanomimetic enzymes. This review also focuses on the applications of those immunosensors in the detection of cancer, Alzheimer's disease, novel coronavirus pneumonia and other diseases. Finally, the future trends in electrochemical immunosensors are addressed in terms of achieving lower detection limits, improving electrode modification capabilities and developing composite functional materials.
Collapse
Affiliation(s)
- Huinan Chen
- College of Sciences, Shanghai University, Shanghai 200444, China
| | - Jialu Zhang
- School of Medicine, Shanghai University, Shanghai 200444, China
| | - Rong Huang
- College of Sciences, Shanghai University, Shanghai 200444, China
| | - Dejia Wang
- College of Sciences, Shanghai University, Shanghai 200444, China
| | - Dongmei Deng
- College of Sciences, Shanghai University, Shanghai 200444, China
| | - Qixian Zhang
- School of Materials Science and Engineering, Shanghai University, Shanghai 200436, China
- Shaoxing Institute of Technology, Shanghai University, Shaoxing 312000, China
| | - Liqiang Luo
- College of Sciences, Shanghai University, Shanghai 200444, China
| |
Collapse
|
11
|
Ranjbari S, Rezayi M, Arefinia R, Aghaee-Bakhtiari SH, Hatamluyi B, Pasdar A. A novel electrochemical biosensor based on signal amplification of Au HFGNs/PnBA-MXene nanocomposite for the detection of miRNA-122 as a biomarker of breast cancer. Talanta 2023; 255:124247. [PMID: 36603443 DOI: 10.1016/j.talanta.2022.124247] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 12/25/2022] [Accepted: 12/30/2022] [Indexed: 01/02/2023]
Abstract
Cancer is one of the leading causes of death worldwide and a crisis for global health. Breast cancer is the second most common cancer globally. In the perusal, a novel electrochemical biosensor amplified with hierarchical flower-like gold, poly (n-butyl acrylate), and MXene (AuHFGNs/PnBA-MXene) nanocomposite and activated by highly special antisense ssDNA (single-stranded DNA) provide a promising alternative for miRNA-122 detection as a biomarker of breast cancer. The biosensor presented a detection limit of 0.0035 aM (S/N = 3) with a linear range from 0.01 aM to 10 nM. The platform was tried on 20 breast cancer miRNAs extracted from actual serum specimens (10 positives and 10 negatives). Founded on the quantitatively obtained outcomes and statistic analysis (t-test, box-graph, receiver performance characteristic curve, and cut-off amount), the biosensor showed a meaningful discrepancy between the native and positive groups with 100% specificity and 100% sensitivity. While, RT-qPCR showed less specificity and sensitivity (70% specificity, 100% sensitivity) than the proposed biosensor. To assess the quantitative capacity and biosensor detection limit for clinical tests, the biosensor diagnosis performance for continually diluted miRNA extracted from patients was compared to that gained by RT-qPCR results, indicating that the biosensor detection limit was lower than RT-qPCR. ssDNA/AuHFGN/PnBA-MXene/GCE displayed little cross-reaction with other sequences and also showed desirable stability, reproducibility, and specificity and stayed stable until 32 days. As a result, the designed biosensor can perform as a hopeful method for diagnosis applications.
Collapse
Affiliation(s)
- Sara Ranjbari
- Chemical Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
| | - Majid Rezayi
- Department of Medical Biotechnology and Nanotechnology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
| | - Reza Arefinia
- Chemical Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Iran.
| | | | - Behnaz Hatamluyi
- Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Alireza Pasdar
- Department of Medical Genetics and Molecular Medicine, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
12
|
An ultrasensitive electrochemical immunosensor for carcinoembryonic antigen detection based on two-dimensional PtPd/Cu-TCPP(Fe) nanocomposites. Anal Bioanal Chem 2023; 415:447-456. [PMID: 36357598 DOI: 10.1007/s00216-022-04425-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 10/23/2022] [Accepted: 11/03/2022] [Indexed: 11/12/2022]
Abstract
Establishing an effective signal amplification strategy is the key to achieving sensitive detection of analytes by electrochemical immunoassay. In this work, a novel sandwich-type electrochemical immunosensor with dual-signal amplification was successfully constructed using PtPd/Cu-TCPP(Fe) as the sensing platform and mesoporous silicon dioxide as the signal amplifier. Firstly, two-dimensional wrinkled Cu-TCPP(Fe) nanomaterials loaded with PtPd nanoparticles have strong affinity for the immobilization of capture antibodies and can generate excellent electrochemical signals. Meanwhile, the mesoporous silicon dioxide with large steric hindrance was used as signal label to further improve the sensitivity of the immunosensor by increasing the difference of the current response signal. Under optimal experimental conditions, the electrochemical immunosensor exhibited a wide linear detection range from 0.1 pg/mL to 1.0 μg/mL, with a detection limit as low as 0.166 fg/mL. The experimental results showed that the constructed immunosensor has a great application prospect in clinical biomarker detection.
Collapse
|
13
|
Wang J, Hua X, Jin B. Ultrasensitive Detection of Carcinoembryonic Antigen by Chitosan/Polythiophene/CdTe Electrochemical Biosensor. ACS OMEGA 2022; 7:45361-45370. [PMID: 36530283 PMCID: PMC9753643 DOI: 10.1021/acsomega.2c05950] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
A facile method for the in situ fabrication of chitosan/polythiophene/CdTe (CS/PTh/CdTe) nanocomposite has been developed. It was then connected with anti-CEA (Ab), which was evoked for the electrochemical detection of carcinoembryonic antigen (CEA, Ag) within K4Fe(CN)6. The results indicate that CS/PTh/CdTe/GCE has a high selectivity for the detection of CEA with a wide linear range of 0.0001-10000 ng/mL and excellent sensitivity with a low detection limit of 40 fg/mL. Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), X-ray photoelectron spectroscopy (XPS), and in situ FT-IR spectra are evoked to study the mechanism of detection of CEA via CS/PTh/CdTe/GCE. The high sensitivity of the electrochemical sensor is due to the fact that the electrochemical oxidation products of K4Fe(CN)6 can directly oxidize CdTe from a low energy state to a high energy state (CdTe)*, making CdTe more prone to be oxidized and facilitate electron transfer. The developed electrochemical biosensor can be used for the detection of real samples, providing a precise method for the detection of CEA with potential application in the clinical detection of tumors.
Collapse
|
14
|
Zhao X, Yang J, Deng W, Tan Y, Xie Q. Construction of a high power-density microbial fuel cell based on lipopolysaccharide-lectin interactions and its application for detecting heavy metal toxicity. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116948] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
15
|
Tan YY, Sun HN, Liu M, Liu A, Li SS. Simple synthesis of PtRu nanoassemblies as signal amplifiers for electrochemical immunoassay of carbohydrate antigen 19-9. Bioelectrochemistry 2022; 148:108263. [PMID: 36162334 DOI: 10.1016/j.bioelechem.2022.108263] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 09/03/2022] [Accepted: 09/08/2022] [Indexed: 11/27/2022]
Abstract
In clinical analysis, carbohydrate antigen 19-9 (CA199) is a gold standard for pancreatic cancer diagnosis. Herein, PtRu nanoassemblies (NAs) were synthesized via a facile one-step solvothermal approach, with the help of octylphenoxypolye thoxyethanol (NP-40) acted as a growth-directing molecule, and triethylene glycol (TEG) worked as a reductant and solvent. During the assembly process of small particles, a large number of voids were formed, which significantly increase the specific surface area of the PtRu NAs exhibiting excellent electrocatalytic performance. Incorporating the PtRu NAs as signal amplifiers for potassium ferrocyanide oxidation into the specific molecular recognition of proteins, a facile signal-enhanced electrochemical (EC) immunosensor was developed. Verified by a series of experiments, the proposed immunosensor presented a wide linear range (10-4-70 U mL-1) and a low detection limit (3.3 × 10-5 U mL-1), accompanied by good reproducibility, selectivity, and stability, which could be applied in human serum samples for the determination of CA199, and was comparable to commercial electrochemiluminescence (ECL) immunoassay. Feasibility of batch fabrication of PtRu NAs makes nanomaterial-based EC immunoassay promising for the determination of similar cancer markers in future.
Collapse
Affiliation(s)
- Yuan-Yuan Tan
- Institute for Chemical Biology & Biosensing, and College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao 266071, China
| | - He-Nan Sun
- Institute for Chemical Biology & Biosensing, and College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao 266071, China
| | - Mingjun Liu
- Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003, China
| | - Aihua Liu
- Institute for Chemical Biology & Biosensing, and College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao 266071, China
| | - Shan-Shan Li
- Institute for Chemical Biology & Biosensing, and College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao 266071, China.
| |
Collapse
|
16
|
Hatamluyi B, Rezayi M, Amel Jamehdar S, Rizi KS, Mojarrad M, Meshkat Z, Choobin H, Soleimanpour S, Boroushaki MT. Sensitive and specific clinically diagnosis of SARS-CoV-2 employing a novel biosensor based on boron nitride quantum dots/flower-like gold nanostructures signal amplification. Biosens Bioelectron 2022; 207:114209. [PMID: 35339072 PMCID: PMC8938305 DOI: 10.1016/j.bios.2022.114209] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Revised: 03/07/2022] [Accepted: 03/19/2022] [Indexed: 02/06/2023]
Abstract
The sudden increase of the COVID-19 outbreak and its continued growth with mutations in various forms has created a global health crisis as well as devastating social and economic effects over the past two years. In this study, a screen-printed carbon electrode reinforced with boron nitride quantum dots/flower-like gold nanostructures (BNQDs/FGNs/SPCE) and functionalized by highly specific antisense DNA oligonucleotide presents an alternative and promising solution for targeting SARS-CoV-2 RNA without nucleic acid amplification. The platform was tested on 120 SARS-CoV-2 RNA isolated from real clinical samples (60 positive and 60 negative confirmed by conventional RT-PCR method). Based on obtained quantitative results and statistical analysis (box-diagram, cutoff value, receiver operating characteristic curve, and t-test), the biosensor revealed a significant difference between the two positive and negative groups with 100% sensitivity and 100% specificity. To evaluate the quantitation capacity and detection limit of the biosensor for clinical trials, the detection performance of the biosensor for continuously diluted RNA isolated from SARS-CoV-2-confirmed patients was compared to those obtained by RT-PCR, demonstrating that the detection limit of the biosensor is lower than or comparable to that of RT-PCR. The ssDNA/BNQDs/FGNs/SPCE showed negligible cross-reactivity with RNA fragments isolated from Influenza A (IAV) clinical samples and also remained stable for up to 14 days. In conclusion, the fabricated biosensor may serve as a promising tool for point-of-care applications.
Collapse
Affiliation(s)
- Behnaz Hatamluyi
- Department of Pharmacology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran; Student Research Committee, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Majid Rezayi
- Medical Toxicology Research Center, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medical Biotechnology and Nanotechnology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Saeid Amel Jamehdar
- Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Microbiology and Virology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Kobra Salimian Rizi
- Isfahan University of Technology, Department of Materials Engineering, Isfahan, Iran
| | - Majid Mojarrad
- Department of Medical Genetics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Zahra Meshkat
- Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Microbiology and Virology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Hamzeh Choobin
- Department of Virology, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| | - Saman Soleimanpour
- Department of Microbiology and Virology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran; Antimicrobial Resistance Research Center, Bu-Ali Research Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Taher Boroushaki
- Department of Pharmacology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran; Pharmacological Research Center of Medicinal Plants, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
17
|
Li SS, Wang AJ, Yuan PX, Mei LP, Zhang L, Feng JJ. Heterometallic nanomaterials: activity modulation, sensing, imaging and therapy. Chem Sci 2022; 13:5505-5530. [PMID: 35694355 PMCID: PMC9116289 DOI: 10.1039/d2sc00460g] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 04/12/2022] [Indexed: 11/23/2022] Open
Abstract
Heterometallic nanomaterials (HMNMs) display superior physicochemical properties and stability to monometallic counterparts, accompanied by wider applications in the fields of catalysis, sensing, imaging, and therapy due to synergistic effects between multi-metals in HMNMs. So far, most reviews have mainly concentrated on introduction of their preparation approaches, morphology control and applications in catalysis, assay of heavy metal ions, and antimicrobial activity. Therefore, it is very important to summarize the latest investigations of activity modulation of HMNMs and their recent applications in sensing, imaging and therapy. Taking the above into consideration, we briefly underline appealing chemical/physical properties of HMNMs chiefly tailored through the sizes, shapes, compositions, structures and surface modification. Then, we particularly emphasize their widespread applications in sensing of targets (e.g. metal ions, small molecules, proteins, nucleic acids, and cancer cells), imaging (frequently involving photoluminescence, fluorescence, Raman, electrochemiluminescence, magnetic resonance, X-ray computed tomography, photoacoustic imaging, etc.), and therapy (e.g. radiotherapy, chemotherapy, photothermal therapy, photodynamic therapy, and chemodynamic therapy). Finally, we present an outlook on their forthcoming directions. This timely review would be of great significance for attracting researchers from different disciplines in developing novel HMNMs.
Collapse
Affiliation(s)
- Shan-Shan Li
- Institute for Chemical Biology & Biosensing, College of Life Sciences, Qingdao University 308 Ningxia Road Qingdao 266071 China
| | - Ai-Jun Wang
- Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University Jinhua 321004 China
| | - Pei-Xin Yuan
- Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University Jinhua 321004 China
| | - Li-Ping Mei
- Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University Jinhua 321004 China
| | - Lu Zhang
- Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University Jinhua 321004 China
| | - Jiu-Ju Feng
- Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University Jinhua 321004 China
| |
Collapse
|
18
|
Bal Altuntaş D, Nalkıran HS, Aslan S, Yolcu Z. Development of MoS2 and Au nanoparticle ıncluding disposable CEA-based immuno-cytosensor platforms. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02240-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
19
|
Eid K, Abdullah AM. Porous Ternary Pt-based Branched Nanostructures for Electrocatalytic Oxygen Reduction. Electrochem commun 2022. [DOI: 10.1016/j.elecom.2022.107237] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
|
20
|
Huang L, Qiu S, Liu Z, Wu S, Tang Q, Liao X, Gao F. Proximity hybridization induced DNA assembly for label-free surface-enhanced Raman spectroscopic detection of carcinoembryonic antigen. Anal Chim Acta 2022; 1191:339314. [PMID: 35033249 DOI: 10.1016/j.aca.2021.339314] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 11/17/2021] [Accepted: 11/21/2021] [Indexed: 11/17/2022]
Abstract
In our research, label-free and surface-enhanced Raman dyes-free Raman spectroscopy which was used to detect carcinoembryonic antigen (CEA) according to poly adenine (Poly A)-regulated self-assembly methods was developed and studied. CEA induced partial hybridization of Ab-H2 and Ab-H1, and Ab-H1-CEA-Ab-H2 (a sandwich proximity CEA-DNA complex) was formed, which unfolded molecular beacon 1 (MB1) and modified the substrate. Subsequently, MB2-AuNPs were hybridized with MB1, and Ab-H1-CEA-Ab-H2 was released via toehold regulated displacements of DNA strands. Therefore, hybridization processes of MB2 and MB1 were induced and promoted by CEA-DNA complexes which worked as catalysts. The misplaced target then induced a next round of strand exchange, and the signals for determination of CEA were amplified by AuNPs absorbed on the substrate. It was indicated that the spectral characteristics of adenine at 736 cm-1 were consistent with the SERS spectrum of DNA. Adenine acted as an internal marker for label-free SERS detection of CEA. Moreover, satisfactory stability and reproducibility were found. Meanwhile, the antibody could specifically recognize the corresponding antigen. Since adenine was dominant in SERS spectra, which was also proximal to Au surface, the sensitivity of the novel method was high without modifications. The analytical performance of this method in determining serum CEA was satisfactory.
Collapse
Affiliation(s)
- Longjian Huang
- West Guangxi Key Laboratory for Prevention and Treatment of High-Incidence Diseases, Youjiang Medical University for Nationalities, 533000, Baise, China
| | - Shang Qiu
- School of Pharmacy, Xuzhou Medical University, 221004, Xuzhou, China
| | - Zhao Liu
- School of Pharmacy, Xuzhou Medical University, 221004, Xuzhou, China
| | - Shengyue Wu
- School of Pharmacy, Xuzhou Medical University, 221004, Xuzhou, China
| | - Qianli Tang
- West Guangxi Key Laboratory for Prevention and Treatment of High-Incidence Diseases, Youjiang Medical University for Nationalities, 533000, Baise, China
| | - Xianjiu Liao
- West Guangxi Key Laboratory for Prevention and Treatment of High-Incidence Diseases, Youjiang Medical University for Nationalities, 533000, Baise, China.
| | - Fenglei Gao
- School of Pharmacy, Xuzhou Medical University, 221004, Xuzhou, China.
| |
Collapse
|
21
|
Huang X, Miao J, Fang J, Xu X, Wei Q, Cao W. Ratiometric Electrochemical Immunosensor Based on L-cysteine Grafted Ferrocene for Detection of Neuron Specific Enolase. Talanta 2021; 239:123075. [PMID: 34809982 DOI: 10.1016/j.talanta.2021.123075] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Revised: 11/08/2021] [Accepted: 11/16/2021] [Indexed: 01/09/2023]
Abstract
In order to realize the ultra sensitive detection of Neuron specific enolase (NSE) in human serum, we chose electrochemical immunosensor as a simple analytical method. During the experiment, we found that the peak value signals of Cu-MOFs-Au and Fc-L-Cys were significantly changed at -0.20 V and 0.20 V potentials by DPV. So a ratiometric electrochemical immunosensor for quantitative analysis of NSE was prepared for Cu-MOFs-Au as the electrode sensing surface and Fc-L-Cys as the label of Ab2. The data and performances of the immunosensor were tested and analyzed by DPV. Cu-MOFs not only provide the required signal for the immunosensor, but also have a large specific surface area, which can provide more sites for the placement of Au nanoparticles. L-cysteine (L-Cys) can prevent a large amount of Fc-COOH leakage, so that Fc+ can stably provide another required signal. With the beefing up of NSE concentration, redox peak of Cu-MOFs-Au decreased and that of Fc-L-Cys raised. The ratio (ΔI=ΔICu/ΔIFc) of two different signals was linear with the logarithm of NSE concentration in a certain value range. In brief, with the optimized experimental conditions, the immunosensor showed excellent performance in the concentration range of 1 pg/mL to 1 μg/mL, and the detection limit was 0.011 pg/mL. Compared with other immunosensors, it showed an unexpected high sensitivity. This method also provided a new idea for the ultra sensitive quantitative detection of other biomarkers.
Collapse
Affiliation(s)
- Xinyi Huang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Juncong Miao
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Jinglong Fang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Xiaoting Xu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Qin Wei
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Wei Cao
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China.
| |
Collapse
|
22
|
Wang F, Xu Y, Han H, Ma Z. In situ growth of electroactive polymers via ATRP to construct a biosensing interface for tumor marker. Mikrochim Acta 2021; 188:389. [PMID: 34676454 DOI: 10.1007/s00604-021-05048-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 10/04/2021] [Indexed: 11/24/2022]
Abstract
A novel biosensing interface for tumor markers was designed based on the atom transfer radical polymerization (ATRP) of poly(isopropenylphenol) (PPPL) in situ initiated by the fixing of p-chloromethyl benzoic acid on the surface of amino-modified electrodes. It was found that the electrochemical activity of PPPL itself can provide sufficient signals for these biosensors, which can avoid signal leakage and streamline the interface modification process. Cu(II) ions absorbed on the carbon spheres and then were released via acid stimulation to act as a catalyst to participate in the interface polymerization with ATRP. As the concentration of targets increased, more Cu(II) ions were released, and the electrochemical signal of polymers was enhanced. Therefore, the sensitive detection of carbohydrate antigen 19-9 (CA19-9) as a model target was achieved, with an ultralow limit of detection of 39 µU mL-1 and wide detection range from 100 µU mL-1 to 100 U mL-1 under optimal conditions. Furthermore, this method achieved satisfying performance in human blood serum with good inter-assay precision (RSD < 6%) and satisfactory recovery of ~ 99-105%. According to the results, this work is of great significance for constructing biosensor interfaces via in situ polymerization. A novel biosensing interface for tumor marker was designed based on atom transfer radical polymerization (ATRP), which poly(isopropenylphenol) with electrochemical signal was fabricated in situ on electrode.
Collapse
Affiliation(s)
- Fei Wang
- Department of Chemistry, Capital Normal University, Beijing, 100048, China
| | - Yang Xu
- Department of Chemistry, Capital Normal University, Beijing, 100048, China
| | - Hongliang Han
- Department of Chemistry, Capital Normal University, Beijing, 100048, China.
| | - Zhanfang Ma
- Department of Chemistry, Capital Normal University, Beijing, 100048, China.
| |
Collapse
|
23
|
New Ultrasensitive Sandwich-Type Immunoassay of Dendritic Tri-Fan Blade-like PdAuCu Nanoparticles/Amine-Functionalized Graphene Oxide for Label-Free Detection of Carcinoembryonic Antigen. MICROMACHINES 2021; 12:mi12101256. [PMID: 34683307 PMCID: PMC8537010 DOI: 10.3390/mi12101256] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 10/12/2021] [Accepted: 10/14/2021] [Indexed: 01/02/2023]
Abstract
The early detection of tumor markers has an effective role in the treatment of cancer. Here, a new sandwich-type electrochemical immunosensor for early label-free detection of the cancer biomarker carcinoembryonic antigen (CEA) was developed. Dendritic tri-fan blade-like PdAuCu nanoparticles (PdAuCu NPs)/amine functionalized graphene oxide (NH2-GO) were the label of secondary antibodies (Ab2), and Au nanoparticle-decorated polydopamines (Au/PDA) were immobilized on a screen-printed carbon electrode (SPCE) as the substrate materials. Dendritic tri-fan blade-like PdAuCu NPs/NH2-GO was synthesized according to a simple hydrothermal procedure and used to immobilize antibodies (Ab2) with large surfaces areas, increased catalytic properties and good adsorption to amplify the current signals. Subsequently, Ab2/PdAuCu NPs/NH2-GO catalyzed the reduction of H2O2 in the sandwich-type immunoreactions. Under optimal conditions, the immunosensor exhibited a satisfactory response to CEA with a limit detection of 0.07 pg mL−1 and a linear detection range from 0.1 pg mL−1 to 200 ng mL−1. The proposed immunosensor could be suitable enough for a real sample analysis of CEA, and has clinical value in the early diagnosis of cancer.
Collapse
|
24
|
Manouchehri S, Zarrintaj P, Saeb MR, Ramsey JD. Advanced Delivery Systems Based on Lysine or Lysine Polymers. Mol Pharm 2021; 18:3652-3670. [PMID: 34519501 DOI: 10.1021/acs.molpharmaceut.1c00474] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Polylysine and materials that integrate lysine form promising drug delivery platforms. As a cationic macromolecule, a polylysine polymer electrostatically interacts with cells and is efficiently internalized, thereby enabling intracellular delivery. Although polylysine is intrinsically pH-responsive, the conjugation with different functional groups imparts smart, stimuli-responsive traits by adding pH-, temperature-, hypoxia-, redox-, and enzyme-responsive features for enhanced delivery of therapeutic agents. Because of such characteristics, polylysine has been used to deliver various cargos such as small-molecule drugs, genes, proteins, and imaging agents. Furthermore, modifying contrast agents with polylysine has been shown to improve performance, including increasing cellular uptake and stability. In this review, the use of lysine residues, peptides, and polymers in various drug delivery systems has been discussed comprehensively to provide insight into the design and robust manufacturing of lysine-based delivery platforms.
Collapse
Affiliation(s)
- Saeed Manouchehri
- School of Chemical Engineering, Oklahoma State University, 420 Engineering North, Stillwater, Oklahoma 74078, United States
| | - Payam Zarrintaj
- School of Chemical Engineering, Oklahoma State University, 420 Engineering North, Stillwater, Oklahoma 74078, United States
| | | | - Joshua D Ramsey
- School of Chemical Engineering, Oklahoma State University, 420 Engineering North, Stillwater, Oklahoma 74078, United States
| |
Collapse
|
25
|
Cen SY, Ge XY, Chen Y, Wang AJ, Feng JJ. Label-free electrochemical immunosensor for ultrasensitive determination of cardiac troponin I based on porous fluffy-like AuPtPd trimetallic alloyed nanodendrites. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106568] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
26
|
Xing G, Luo B, Qin J, Wang X, Hou P, Zhang H, Wang C, Wang J, Li A. A probe-free electrochemical immunosensor for methyl jasmonate based on ferrocene functionalized-carboxylated graphene-multi-walled carbon nanotube nanocomposites. Talanta 2021; 232:122477. [PMID: 34074445 DOI: 10.1016/j.talanta.2021.122477] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 04/21/2021] [Accepted: 04/26/2021] [Indexed: 11/29/2022]
Abstract
Methyl jasmonate (MeJA) is an endogenous plant hormone, which plays an important role in agriculture production. A novel probe-free electrochemical immunosensor was fabricated for detecting of MeJA. Fc, carboxylated graphene (COOH-GR) and carboxylated multi-walled carbon nanotubes (COOH-MWNT) composite was formed and used to fabricate screen-printed electrode (SPE). Fc was used as the electronic medium. COOH-GR and COOH-MWNT were used to improve the conductivity and catalytic activity of the sensor and to immobilize the MeJA antibody. Thus, the immunosensor can be used to detect MeJA without external redox probe solution. The designed sensor can detect MeJA in a wide range of 100 fM-100 μM, and its detection limit is as low as 31.26 fM (S/N = 3). The as-prepared probe-free immunosensor is simple, low cost, and does not need redox probe solutions for measurements, which shows great promise for future application in precision agriculture.
Collapse
Affiliation(s)
- Gengqi Xing
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China; College of Landscape and Ecological Engineering, Hebei University of Engineering, Handan, 056038, China
| | - Bin Luo
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China
| | - Junqing Qin
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China
| | - Xiaodong Wang
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China
| | - Peichen Hou
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China
| | - Han Zhang
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China
| | - Cheng Wang
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China; School of Agricultural Equipment Engineering, Jiangsu University, Zhenjiang, 212013, China
| | - Jianshu Wang
- College of Landscape and Ecological Engineering, Hebei University of Engineering, Handan, 056038, China.
| | - Aixue Li
- Beijing Research Center for Information Technology in Agriculture, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China; School of Agricultural Equipment Engineering, Jiangsu University, Zhenjiang, 212013, China.
| |
Collapse
|
27
|
Liao X, Wang X, Ma C, Zhang L, Zhao C, Chen S, Li K, Zhang M, Mei L, Qi Y, Hong C. Enzyme-free sandwich-type electrochemical immunosensor for CEA detection based on the cooperation of an Ag/g-C 3N 4-modified electrode and Au@SiO 2/Cu 2O with core-shell structure. Bioelectrochemistry 2021; 142:107931. [PMID: 34455230 DOI: 10.1016/j.bioelechem.2021.107931] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 08/08/2021] [Accepted: 08/12/2021] [Indexed: 02/07/2023]
Abstract
Effective signal amplification is a prerequisite for electrochemical immunosensors to achieve ultra-sensitive detection. In this work, we prepared a sandwich-type electrochemical immunosensor for the quantitative detection of carcinoembryonic antigen (CEA). As a base platform, Ag NPs modified aminated two-dimensional nitrogen carbide nanosheets (Ag/g-C3N4) have good biocompatibility and conductivity. In addition, with the layered structure of Au@SiO2/Cu2O as the signal label, the response current value of H2O2 was monitored by the Amperometric i-t Curve (i-t), so as to realize the accurate measurement of CEA. The presence of SiO2 nanoframes not only reduces the agglomeration of Au NPs and Cu2O but also provides good biocompatibility to facilitate the connection of secondary antibodies. Finally, we also verified the signal amplification mechanism of the immunosensor through XPS and other means, and calculated the kinetic parameters of the signal tag, which proved the good peroxidase-like activity of Au@SiO2/Cu2O. Under the best test conditions, the prepared immunosensor has a detection range from 0.01 pg/mL to 80 ng/mL, and the detection limit is as low as 0.0038 pg/mL. The results show that the immunosensor has good analytical performance and it can provide a new method for the clinical diagnosis of CEA.
Collapse
Affiliation(s)
- Xiaochen Liao
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, PR China
| | - Xiao Wang
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, PR China
| | - Chaoyun Ma
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, PR China
| | - Li Zhang
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, PR China
| | - Chulei Zhao
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, PR China
| | - Siyu Chen
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, PR China
| | - Keqiang Li
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, PR China
| | - Mengmeng Zhang
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, PR China
| | - Lisha Mei
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, PR China
| | - Yu Qi
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, PR China.
| | - Chenglin Hong
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, PR China.
| |
Collapse
|
28
|
Ding M, Liu J, Yang J, Wang H, Xie X, Yang X, Li Y, Guo N, Ouyang R, Miao Y. How do bismuth-based nanomaterials function as promising theranostic agents for the tumor diagnosis and therapy? Curr Med Chem 2021; 29:1866-1890. [PMID: 34365944 DOI: 10.2174/0929867328666210806123008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 06/17/2021] [Accepted: 06/29/2021] [Indexed: 11/22/2022]
Abstract
The complexity of tumor microenvironment and the diversity of tumors seriously affect the therapeutic effect, the focus, therefore, has gradually been shifted from monotherapy to combination therapy in clinical research in order to improve the curative effect. The synergistic enhancement interactions among multiple monotherapies majorly contribute to the birth of the multi-mode cooperative therapy, whose effect of the treatment is clearly stronger than that of any single therapy. In addition, the accurate diagnosis of the tumour location is also crucial to the treatment. Bismuth-based nanomaterials (NMs) hold great properties as promising theranostic platforms based on their many unique features that include low toxicity, excellent photothermal conversion efficiency as well as high ability of X-ray computed tomography imaging and photoacoustic imaging. In this review, we will introduce briefly the main features of tumor microenvironment first and its effect on the mechanism of nanomedicine actions and present the recent advances of bismuth-based NMs for diagnosis and photothermal therapy-based combined therapies using bismuth-based NMs are presented, which may provide a new way for overcoming drug resistance and hypoxia. At the end, further challenges and outlooks regarding this promising field are discussed accompanied with some design tips for bismuth-based NMs, hoping to provide researchers some inspirations to design safe and effective nanotherapeutic agents for the clinical treatments of cancers.
Collapse
Affiliation(s)
- Mengkui Ding
- Institute of Bismuth Science, University of Shanghai for Science and Technology, Shanghai 200093. China
| | - Jinyao Liu
- Institute of Bismuth Science, University of Shanghai for Science and Technology, Shanghai 200093. China
| | - Junlei Yang
- Institute of Bismuth Science, University of Shanghai for Science and Technology, Shanghai 200093. China
| | - Hui Wang
- Institute of Bismuth Science, University of Shanghai for Science and Technology, Shanghai 200093. China
| | - Xianjin Xie
- Institute of Bismuth Science, University of Shanghai for Science and Technology, Shanghai 200093. China
| | - Xiaoyu Yang
- Institute of Bismuth Science, University of Shanghai for Science and Technology, Shanghai 200093. China
| | - Yuhao Li
- Institute of Bismuth Science, University of Shanghai for Science and Technology, Shanghai 200093. China
| | - Ning Guo
- Institute of Bismuth Science, University of Shanghai for Science and Technology, Shanghai 200093. China
| | - Ruizhuo Ouyang
- Institute of Bismuth Science, University of Shanghai for Science and Technology, Shanghai 200093. China
| | - Yuqing Miao
- Institute of Bismuth Science, University of Shanghai for Science and Technology, Shanghai 200093. China
| |
Collapse
|
29
|
Cao L, Tan Y, Deng W, Xie Q. MWCNTs-CoP hybrids for dual-signal electrochemical immunosensing of carcinoembryonic antigen based on overall water splitting. Talanta 2021; 233:122521. [PMID: 34215136 DOI: 10.1016/j.talanta.2021.122521] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 05/09/2021] [Accepted: 05/11/2021] [Indexed: 11/16/2022]
Abstract
Great efforts have been made to search for highly active catalysts toward electrochemical water splitting, but double-signal immunosensors have not been reported based on bifunctional water splitting electrocatalysts. We report here a dual-signal electrochemical immunosensor for detecting carcinoembryonic antigen (CEA) using multi-wall carbon nanotubes (MWCNTs)-cobalt phosphide (CoP) as an electrocatalytic label. The preparation of MWCNTs-CoP involves the growth of Co3O4 nanoparticles on MWCNTs and low-temperature phosphatization of Co3O4 nanoparticles. The MWCNTs-CoP catalyst shows excellent electrocatalytic activities in a neutral medium toward both hydrogen evolution reaction (HER) and oxygen evolution reaction (OER), enabling MWCNTs-CoP as the electrocatalytic label for sensitive immunosensing. The linear range of the sandwich-type immunosensor for detecting CEA based on the HER signal is from 10-4-100 ng mL-1, whereas a linear range for detecting CEA based on the OER signal is achieved from 10-4 to 10 ng mL-1. The detection limits for detecting CEA using HER and OER signals are 10 and 12 fg mL-1, respectively. This work can provide a new double-signal immunosensing platform based on a bifunctional water splitting electrocatalyst.
Collapse
Affiliation(s)
- Lin Cao
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, 410081, China
| | - Yueming Tan
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, 410081, China.
| | - Wenfang Deng
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, 410081, China
| | - Qingji Xie
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education of China), College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, 410081, China
| |
Collapse
|
30
|
Advanced sensitivity amplification strategies for voltammetric immunosensors of tumor marker: State of the art. Biosens Bioelectron 2021; 178:113021. [DOI: 10.1016/j.bios.2021.113021] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 11/27/2020] [Accepted: 01/18/2021] [Indexed: 12/24/2022]
|
31
|
Li SS, Tan YY, Zhang Y, Liu M, Liu A. A simple electrochemical immunosensor based on worm-like platinum for highly sensitive determination of alpha-fetoprotein. Bioelectrochemistry 2021; 140:107804. [PMID: 33813145 DOI: 10.1016/j.bioelechem.2021.107804] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 03/17/2021] [Accepted: 03/18/2021] [Indexed: 12/20/2022]
Abstract
Alpha-fetoprotein (AFP) has become a specific tumor marker of primary liver cancer in clinical diagnosis. In this work, we prepared worm-like platinum (WL Pt) nanomaterial via chemical etching without organic solvents and ultra-high temperature. Due to its small particle size and the formation of surface vacancies during the etching process, it had a large specific surface area, and thus exhibited superior electrocatalytic activity for the reduction of hydrogen peroxide. Combining the signal amplification based on hydrogen peroxide reduction and the specific recognition of antigen with antibody, we constructed a simple label-free electrochemical immunosensor with a sandwich-like structure. The developed electrochemical immunosensor showed a wide linear range (0.0001-100 ng mL-1), a low detection limit (0.028 pg mL-1), good selectivity and stability. Further, the immunosensor was comparable with enzyme-linked immunosorbent assay (ELISA) and had a good accuracy for AFP detection in human serum samples proving the feasibility of potential application, which is expect to become one of the most promising method in early diagnosis and clinical analysis for liver cancer.
Collapse
Affiliation(s)
- Shan-Shan Li
- Institute for Chemical Biology & Biosensing, and College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao 266071, China.
| | - Yuan-Yuan Tan
- Institute for Chemical Biology & Biosensing, and College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao 266071, China
| | - Yan Zhang
- Institute for Chemical Biology & Biosensing, and College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao 266071, China
| | - Mingjun Liu
- Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003, China
| | - Aihua Liu
- Institute for Chemical Biology & Biosensing, and College of Life Sciences, Qingdao University, 308 Ningxia Road, Qingdao 266071, China
| |
Collapse
|
32
|
Wang XY, Feng YG, Wang AJ, Mei LP, Luo X, Xue Y, Feng JJ. Facile construction of ratiometric electrochemical immunosensor using hierarchical PtCoIr nanowires and porous SiO 2@Ag nanoparticles for accurate detection of septicemia biomarker. Bioelectrochemistry 2021; 140:107802. [PMID: 33794412 DOI: 10.1016/j.bioelechem.2021.107802] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 03/09/2021] [Accepted: 03/12/2021] [Indexed: 12/19/2022]
Abstract
Procalcitonin (PCT) is a sensitive and specific biomarker for sepsis diagnosis. In this study, a novel ratio-typed electrochemical immunosensor was constructed for reliable and sensitive assay of PCT based on hierarchical PtCoIr nanowires/polyethylene polyamine-grafted-ferrocene (PtCoIr HNWs/PEPA-Fc) and porous SiO2@Ag nanoparticles-toluidine blue (porous SiO2@Ag NPs-TB). Importantly, the PtCoIr HNWs/PEPA-Fc was first modified on the sensing interface, which harvested stable and strong electrochemical signals for readout of Fc due to the enriched anchoring sites created by the PtCoIr HNWs. Meanwhile, porous SiO2@Ag NPs-TB behaved as the label to conjugate with secondary antibody (Ab2), which also provided another strong detection signals originated from TB confined in such porous structures. The resulting immunosensor displayed a measurable output of procalcitonin (PCT) in the dynamic scope of 0.001 ~ 100 ng mL-1 with a low limit of detection (LOD) of 0.46 pg mL-1 (S/N = 3). Moreover, we exploited this strategy for PCT assay in a diluted human serum sample with acceptable results, exhibiting promising applications in the clinical analysis.
Collapse
Affiliation(s)
- Xiao-Yu Wang
- Jinhua Central Hospital, Jinhua 321001, China; Key laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Yi-Ge Feng
- Key laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Ai-Jun Wang
- Key laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Li-Ping Mei
- Key laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Xiliang Luo
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Sciences, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, China
| | - Yadong Xue
- Jinhua Central Hospital, Jinhua 321001, China.
| | - Jiu-Ju Feng
- Key laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China.
| |
Collapse
|
33
|
Zhang X, Zhi H, Zhu M, Wang F, Meng H, Feng L. Electrochemical/visual dual-readout aptasensor for Ochratoxin A detection integrated into a miniaturized paper-based analytical device. Biosens Bioelectron 2021; 180:113146. [PMID: 33714160 DOI: 10.1016/j.bios.2021.113146] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 03/01/2021] [Accepted: 03/03/2021] [Indexed: 12/13/2022]
Abstract
Development of portable, sensitive and reliable devices for Ochratoxin A (OTA) detection is highly demanded, especially for resource-limited regions. Herein, a novel paper-based analytical device (PAD) is designed through wax printing and screen-printed technologies, which integrates sample flowing, electrode modification, cleaning and electrochemical (EC)/colorimetric signal output. To greatly enhance the detection sensitivity, we synthesized a chitosan functionalized MoS2-Au@Pt (Ch-MoS2-Au@Pt) via electrostatic self-assembly, and used it to immobilize the label aptamer (apta2) for signal regulation and amplification. Concretely, with the addition of analytes, the Ch-MoS2-Au@Pt-apta2 could be combined on the sensing interface by specific biorecognition and catalyzed reduction of H2O2, resulting in a remarkable EC response. Meanwhile, the released hydroxyl radicals (·OH) flowed to the visualization zone and promoted the oxidation of 3,3',5,5'-tetramethylbenzidine for colorimetric detection. Consequently, the dual-mode PAD achieved acceptable prediction and accurate analysis in the range of 0.1-200 ng mL-1 and 1 × 10-4-200 ng mL-1 by matching the visual and EC signal intensity, respectively. Compared with traditional single-mode sensor for OTA, the proposed dual-mode aptasensor featuring independent signal conversion and readout, not only avoided the false-positive signal associated with detection condition and operation, but also enlarged the detection ranges and improved the sensitivity. Furthermore, the consistency of EC/colorimetric assay was validated in real OTA samples. Overall, this work provided a portable, cost-effective, sensitive and visualized aptasensor platform, which could be extended to various other mycotoxins in the field of food safety.
Collapse
Affiliation(s)
- Xiaobo Zhang
- Department of Instrumentation and Analytical Chemistry, CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Hui Zhi
- Department of Instrumentation and Analytical Chemistry, CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Mingzhen Zhu
- Department of Instrumentation and Analytical Chemistry, CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Fengya Wang
- Department of Instrumentation and Analytical Chemistry, CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Hu Meng
- Department of Instrumentation and Analytical Chemistry, CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, PR China
| | - Liang Feng
- Department of Instrumentation and Analytical Chemistry, CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, PR China.
| |
Collapse
|
34
|
Electrochemical biosensors for measurement of colorectal cancer biomarkers. Anal Bioanal Chem 2021; 413:2407-2428. [PMID: 33666711 DOI: 10.1007/s00216-021-03197-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 01/15/2021] [Accepted: 01/23/2021] [Indexed: 02/06/2023]
Abstract
Colorectal cancer (CRC) is associated with one of the highest rates of mortality among cancers worldwide. The early detection and management of CRC is imperative. Biomarkers play an important role in CRC screening tests, CRC treatment, and prognosis and clinical management; thus rapid and sensitive detection of biomarkers is helpful for early detection of CRC. In recent years, electrochemical biosensors for detecting CRC biomarkers have been widely investigated. In this review, different electrochemical detection methods for CRC biomarkers including immunosensors, aptasensors, and genosensors are summarized. Further, representative examples are provided that demonstrate the advantages of electrochemical sensors modified by various nanomaterials. Finally, the limitations and prospects of biomarkers and electrochemical sensors in detection are also discussed. Graphical abstract.
Collapse
|
35
|
Feng YG, Wang XY, Wang ZW, Wang AJ, Mei LP, Luo X, Feng JJ. A label-free electrochemical immunosensor based on encapsulated signal molecules in mesoporous silica-coated gold nanorods for ultrasensitive assay of procalcitonin. Bioelectrochemistry 2021; 140:107753. [PMID: 33631415 DOI: 10.1016/j.bioelechem.2021.107753] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 01/28/2021] [Accepted: 01/30/2021] [Indexed: 02/07/2023]
Abstract
For immobilization and signal amplification of the probes, it is feasible and promising by using porous nanomaterials as nanocarriers. Herein, a novel label-free electrochemical immmunosensor was efficiently designed for ultrasensitive detection of procalcitonin (PCT). The immunosensor was prepared by using porous silica-coated gold nanorods (Au NRs@m-SiO2) to load electroactive dye thionine (Thi) on the electrode surface. Apart from the improved electrical conductivity, the porous feature highly increased the loading amount of Thi to boost the detection signals, while the good biocompatibility and protective microenvironment are beneficial to the largely improved stability for the target. For quantification of PCT, the developed immunosensor exhibited a good linear relationship in the antigen concentration range of 0.001-100 ng mL-1 with an ultra-low limit of detection (LOD, 0.39 pg mL-1, S/N = 3). Moreover, the built platform was successfully applied to such assay in human serum samples. The research provides some valuable guidelines for clinical screening and diagnosis of other biomarkers.
Collapse
Affiliation(s)
- Yi-Ge Feng
- Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Xiao-Yu Wang
- Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Zhi-Wu Wang
- Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Ai-Jun Wang
- Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Li-Ping Mei
- Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| | - Xiliang Luo
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Sciences, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, China
| | - Jiu-Ju Feng
- Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, College of Chemistry and Life Sciences, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China.
| |
Collapse
|
36
|
Feng YG, Zhu JH, Wang XY, Wang AJ, Mei LP, Yuan PX, Feng JJ. New advances in accurate monitoring of breast cancer biomarkers by electrochemistry, electrochemiluminescence, and photoelectrochemistry. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115010] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
37
|
Aslan S. An electrochemical immunosensor modified with titanium IV oxide/polyacrylonitrile nanofibers for the determination of a carcinoembryonic antigen. NEW J CHEM 2021. [DOI: 10.1039/d0nj05385f] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
A highly sensitive electrochemical carcinoembryonic antigen immunosensor based on TiO2np/polyacrylonitrile nanofibers electrospun on the surface of the discharged battery coal electrode.
Collapse
Affiliation(s)
- Sema Aslan
- Department of Chemistry
- Faculty of Science
- Mugla Sitki Kocman University
- Muğla
- Turkey
| |
Collapse
|
38
|
Miao J, Du K, Li X, Xu X, Dong X, Fang J, Cao W, Wei Q. Ratiometric electrochemical immunosensor for the detection of procalcitonin based on the ratios of SiO2-Fc–COOH–Au and UiO-66-TB complexes. Biosens Bioelectron 2021; 171:112713. [DOI: 10.1016/j.bios.2020.112713] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 09/22/2020] [Accepted: 10/07/2020] [Indexed: 12/15/2022]
|
39
|
Ding M, Zha L, Wang H, Liu J, Chen P, Zhao Y, Jiang L, Li Y, Ouyang R, Miao Y. A frogspawn-like Ag@C core–shell structure for an ultrasensitive label-free electrochemical immunosensing of carcinoembryonic antigen in blood plasma. RSC Adv 2021; 11:16339-16350. [PMID: 35479148 PMCID: PMC9030918 DOI: 10.1039/d1ra00910a] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Accepted: 04/18/2021] [Indexed: 12/31/2022] Open
Abstract
Novel frogspawn-like Ag@C nanoparticles were successfully used to fabricate an ultrasensitive electrochemical immunosensing platform toward CEA in human blood samples.
Collapse
Affiliation(s)
- Mengkui Ding
- Institute of Bismuth Science
- University of Shanghai for Science and Technology
- Shanghai 200093
- P. R. China
| | - Ling Zha
- Department of Laboratory Diagnosis
- Changhai Hospital
- Naval Medical University
- Shanghai 20043
- P. R. China
| | - Hui Wang
- Institute of Bismuth Science
- University of Shanghai for Science and Technology
- Shanghai 200093
- P. R. China
| | - Jinyao Liu
- Institute of Bismuth Science
- University of Shanghai for Science and Technology
- Shanghai 200093
- P. R. China
| | - Peiwu Chen
- Institute of Bismuth Science
- University of Shanghai for Science and Technology
- Shanghai 200093
- P. R. China
| | - Yuefeng Zhao
- Institute of Bismuth Science
- University of Shanghai for Science and Technology
- Shanghai 200093
- P. R. China
| | - Lan Jiang
- Institute of Bismuth Science
- University of Shanghai for Science and Technology
- Shanghai 200093
- P. R. China
| | - Yuhao Li
- Institute of Bismuth Science
- University of Shanghai for Science and Technology
- Shanghai 200093
- P. R. China
| | - Ruizhuo Ouyang
- Institute of Bismuth Science
- University of Shanghai for Science and Technology
- Shanghai 200093
- P. R. China
| | - Yuqing Miao
- Institute of Bismuth Science
- University of Shanghai for Science and Technology
- Shanghai 200093
- P. R. China
| |
Collapse
|
40
|
Román T, Ramirez D, Fierro-Medina R, Santillan R, Farfán N. Ferrocene and Organotin (IV) Conjugates Containing Amino Acids and Peptides: A Promising Strategy for Searching New Therapeutic and Diagnostic Tools. CURR ORG CHEM 2020. [DOI: 10.2174/1385272824999201001154259] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Organometallic complexes are an important class of synthetic reagents and are of
great interest due to their versatility and wide biological application. The cationic nature of the
coordination nucleus facilitates its interaction with biological molecules such as amino acids,
proteins, and nucleic acids. The functionalization of peptides or amino acids with organometallic
motifs is a novel strategy for the design and development of molecules with greater biological
activity, stability in biological environments, and selectivity for specific targets, which
make them valuable tools for designing and obtaining molecules with therapeutic applications.
The physicochemical properties of ferrocene make it ideal for drug development, due to its
structure, stability in aqueous solutions, redox properties, and low toxicity. In the same way,
organotin (IV) derivatives have great potential for drug development because of their multiple
biological activities, wide structural versatility, high degree of stability, and low toxicity.
However, the synthesis of these drugs based on organometallic molecules containing ferrocene or organotin (IV) is
quite complex and represents a challenge nowadays; for this reason, it is necessary to design and implement procedures
to obtain molecules with a high degree of purity, in sufficient quantities, and at low cost. This review describes
the strategies of synthesis used up to now for the preparation of organometallic amino acids and peptides
containing ferrocene or organotin (IV) derivates, as well as their impact on the development of therapeutic agents.
Collapse
Affiliation(s)
- Tatiana Román
- Departamento de Farmacia, Universidad Nacional de Colombia, Carrera 45 # 26-85, Bogota D.C., Colombia
| | - David Ramirez
- Departamento de Quimica. Facultad de Ciencias, Universidad Nacional de Colombia, Carrera 45 # 26-85, Bogota D.C., Colombia
| | - Ricardo Fierro-Medina
- Departamento de Quimica. Facultad de Ciencias, Universidad Nacional de Colombia, Carrera 45 # 26-85, Bogota D.C., Colombia
| | - Rosa Santillan
- Departamento de Quimica, Centro de Investigacion y de Estudios Avanzados del IPN, Av Instituto Politecnico Nacional 2508, San Pedro Zacatenco, Gustavo A. Madero, 07360 Ciudad de Mexico, CDMX, Mexico
| | - Norberto Farfán
- Facultad de Quimica, Departamento de Quimica Organica, Universidad Nacional Autonoma de Mexico, Av. Universidad 3000, Circuito Exterior S/N Delegacion Coyoacan, C.P. 04510 Ciudad Universitaria, Ciudad de Mexico, CDMX, Mexico
| |
Collapse
|
41
|
Yu X, Li X, Zhang S, Jia Y, Xu Z, Li X, Chen Z, Li Y. Ultrasensitive electrochemical detection of neuron-specific enolase based on spiny core-shell Au/Cu xO@CeO 2 nanocubes. Bioelectrochemistry 2020; 138:107693. [PMID: 33291001 DOI: 10.1016/j.bioelechem.2020.107693] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 10/27/2020] [Accepted: 11/01/2020] [Indexed: 02/07/2023]
Abstract
As a specific biomarker, neuron-specific enolase (NSE) is an essential clinical indicator for diagnosing small cell lung cancer. In this paper, a sandwich-type electrochemical immunosensor was designed for the quantitative detection of NSE. AuPt nanoblock spherical nanoarchitectonics (AuPt NSNs), a bimetallic nanoparticle with a rugged morphology, were utilized as the substrate, which could enhance the electronic conduction and increase the immobilization capacity of the primary antibody (Ab1). Moreover, through a simple hydrothermal method, Au/CuxO@CeO2 was prepared as a spiny core-shell nanocube with cerium dioxide (CeO2) and gold nanoparticles (Au NPs) loading. The combination of Cu2O, CuO, and CeO2 showed favorable catalytic activity toward hydrogen peroxide (H2O2). Furthermore, the deposition of Au NPs on the spiny surface structure enhanced the specific surface area and biocompatibility, thereby rendering it more effective for loading the second antibody (Ab2). As the label material, the Au/CuxO@CeO2 achieved signal amplification and sensitive detection with the immunosensor. Under optimal conditions, the designed immunosensor possessed a broad linear range of 50 fg mL-1 to 100 ng mL-1 and a limit of detection of 31.3 fg mL-1, along with satisfactory performance in sensitivity, selectivity, and stability.
Collapse
Affiliation(s)
- Xiaodong Yu
- School of Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China
| | - Xinjin Li
- School of Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China.
| | - Shuan Zhang
- School of Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China
| | - Yilei Jia
- School of Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China
| | - Zhen Xu
- School of Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China
| | - Xiangye Li
- School of Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China
| | - Zhiwei Chen
- School of Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China
| | - Yueyun Li
- School of Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China.
| |
Collapse
|
42
|
Bu SJ, Wang KY, Liu X, Ma L, Wei HG, Zhang WG, Liu WS, Wan JY. Ferrocene-functionalized nanocomposites as signal amplification probes for electrochemical immunoassay of Salmonella typhimurium. Mikrochim Acta 2020; 187:600. [PMID: 33034762 DOI: 10.1007/s00604-020-04579-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Accepted: 09/29/2020] [Indexed: 02/07/2023]
Abstract
An electrochemical immunosensor based on ferrocene (Fc)-functionalized nanocomposites was fabricated as an efficient electroactive signal probe to amplify electrochemical signals for Salmonella typhimurium detection. The electrochemical signal amplification probe was constructed by encapsulating ferrocene into S. typhimurium-specific antimicrobial peptides Magainin I (MI)-Cu3(PO4)2 organic-inorganic nanocomposites (Fc@MI) through a one-step process. Magnetic beads (MBs) coupled with antibody were used as capture ingredient for target magnetic separation, and Fc@MI nanoparticles were used as signal labels in the immunoassays. The sandwich of MBs-target-Fc@MI assay was performed using a screen-printed carbon electrode as transducer surface. The immunosensor platform presents a low limit of detection (LOD) of 3 CFU·mL-1 and a linear range from 10 to 107 CFU·mL-1, with good specificity and precision, and was successfully applied for S. typhimurium detection in milk. Graphical abstract One-pot process antimicrobial peptides Magainin I-Cu3(PO4)2 organic-inorganic nanocomposites (Fc@MI) were used as ideal electrochemical signal label, integrating both essential functions of biological recognition and signal amplification. Screen-printed carbon electrode (SPCE) was used as the electrochemical system for Salmonella typhimurium detection.
Collapse
Affiliation(s)
- Sheng-Jun Bu
- Institute of Military Veterinary, Academy of Military Medical Sciences, Changchun, 130122, China
| | - Kui-Yu Wang
- Institute of Military Veterinary, Academy of Military Medical Sciences, Changchun, 130122, China.,Southern Laboratory of Ocean Science and Engineering, School of Chemical Engineering and Technology, Sun Yat-sen University, Guangzhou, 519082, Guangdong, China
| | - Xiu Liu
- Institute of Military Veterinary, Academy of Military Medical Sciences, Changchun, 130122, China
| | - Li Ma
- Institute of Military Veterinary, Academy of Military Medical Sciences, Changchun, 130122, China
| | - Hong-Guo Wei
- Institute of Military Veterinary, Academy of Military Medical Sciences, Changchun, 130122, China
| | - Wen-Guang Zhang
- Institute of Military Veterinary, Academy of Military Medical Sciences, Changchun, 130122, China
| | - Wen-Sen Liu
- Institute of Military Veterinary, Academy of Military Medical Sciences, Changchun, 130122, China.
| | - Jia-Yu Wan
- Institute of Military Veterinary, Academy of Military Medical Sciences, Changchun, 130122, China.
| |
Collapse
|
43
|
Covalent attachment of laccase to carboxymethyl-botryosphaeran in aqueous solution for the construction of a voltammetric biosensor to quantify quercetin. Bioelectrochemistry 2020; 135:107543. [PMID: 32450282 DOI: 10.1016/j.bioelechem.2020.107543] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 04/22/2020] [Accepted: 04/29/2020] [Indexed: 11/20/2022]
Abstract
Laccase from Botryosphaeria rhodina MAMB-05 was covalently immobilized on carboxymethyl-botryosphaeran by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide (EDC/NHS) in aqueous solution. This approach was employed to fabricate a novel laccase-based biosensor to electrochemically quantify quercetin (QCT), using a simple carbon black paste electrode as a transducer. The proposed biosensor was characterized by electrochemical impedance spectroscopy and Nyquist plots were used to evaluate the immobilization of the enzyme. For determining QCT, variables were optimized, that included experimental conditions for laccase immobilization, pH of the supporting electrolyte, and instrumental parameters of the electroanalytical technique. From square-wave-voltammograms, a linear dependence between the cathodic current peak and QCT concentration was observed within the range 4.98-50.0 × 10-8 mol L-1, with a theoretical detection limit of 2.6 × 10-8 mol L-1. The proposed method was successfully applied to determine QCT in beverages, pharmaceuticals, and biological samples. The proposed biosensor device presented good selectivity in the presence of uric acid, various inorganic ions, as well as other phenolic compounds, demonstrating the potential application of this biosensing platform in chemically complex solutions. Operational and analytical stability of the laccase-biosensor were evaluated, and good intra-day (SD = 1.23%) and inter-day (SD = 2.32%) repeatability, and long storage stability (SD = 3.47%) are presented.
Collapse
|
44
|
Medetalibeyoglu H, Kotan G, Atar N, Yola ML. A novel sandwich-type SERS immunosensor for selective and sensitive carcinoembryonic antigen (CEA) detection. Anal Chim Acta 2020; 1139:100-110. [PMID: 33190692 DOI: 10.1016/j.aca.2020.09.034] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 08/29/2020] [Accepted: 09/17/2020] [Indexed: 01/09/2023]
Abstract
Monitoring the malignant tumors via cancer biomarkers is very significant process. Nonetheless, the practical clinical applications need selective and sensitive analytical methods/techniques. In this study, a novel sandwich type immunosensor based on surface-enhanced raman scattering (SERS) was presented including 4-mercaptobenzoic acid labeled MoS2 nanoflowers@Au nanoparticles (MoS2 NFs@Au NPs/ MBA) as CEASERS tag and Fe3O4@Au nanoparticles functionalized delaminated Ti3C2Tx MXene (Fe3O4 NPs@Au NPs/d-Ti3C2TX MXene) as SERS magnetic supporting substrate for carcinoembryonic antigen (CEA) detection. Especially, the determination of single molecule by using SERS method enables early diagnosis of major diseases. In addition, this technique can be utilized for multiplex analyzes owing to narrow well-resolved peaks. The prepared CEASERS tag and SERS magnetic supporting substrate were characterized by scanning electron microscope (SEM), x-ray diffraction (XRD) method, x-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM) and fourier transform infrared spectroscopy (FTIR). A linearity of 0.0001-100.0 ng mL-1 was observed with high sensitivity. Finally, sandwich type immunosensor demonstrated good selectivity and stability for target CEA recognition in plasma sample.
Collapse
Affiliation(s)
- Hilal Medetalibeyoglu
- Kafkas University, Faculty of Science and Letters, Department of Chemistry, Kars, Turkey
| | - Gül Kotan
- Kafkas University, Department of Chemistry and Chemical Processing Technologies, Kars Vocational School, Kars, Turkey
| | - Necip Atar
- Pamukkale University, Faculty of Engineering, Department of Chemical Engineering, Denizli, Turkey
| | - Mehmet Lütfi Yola
- Iskenderun Technical University, Faculty of Engineering and Natural Sciences, Department of Biomedical Engineering, Hatay, Turkey.
| |
Collapse
|
45
|
Kang J, Li Z, Wang G. A novel signal amplification strategy electrochemical immunosensor for ultra-sensitive determination of p53 protein. Bioelectrochemistry 2020; 137:107647. [PMID: 32971485 DOI: 10.1016/j.bioelechem.2020.107647] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 08/17/2020] [Accepted: 08/31/2020] [Indexed: 12/20/2022]
Abstract
In this work, we fabricated a novel sandwich-type electrochemical immunosensor for quantitative and ultra-sensitive determination of tumor suppressor protein p53 by signal amplification strategy. Conductive polymers poly (3, 4-ethylenedioxythiophene): polystyrenesulfonate (PEDOT:PSS) has significantly effect on enhancing charge transfer and markedly increases the sensitivity of electrochemical immunosensing. Gold nanoparticles (AuNPs) as high conductivity nanocarriers were also used to capture monoclonal antibodies (Ab1) due to their large specific surface areas. In addition, pH responsive zeolitic imidazolate framework (ZIF-8) was used to load the redox probe 2, 3-diaminophenazine (DAP) and the secondary antibodies (Ab2) to form a sensitive-type ZIF-8-DAP-Ab2 immunoprobe. After the sandwich-type immunoassay with the free p53 protein, with the release of probe DAP after the electrochemical signal amplificated by PEDOT:PSS and AuNPs, the ultra-sensitive and quantitative determination of p53 protein was realized with working range of 1-120 ng mL-1 and low detection limit of 0.09 ng mL-1. Besides, the fabricated electrochemical immunosensor exhibited good recovery, high sensitivity, reliability, and selectivity.
Collapse
Affiliation(s)
- Jian Kang
- College of Pharmacy & the Key Laboratory for Medical Tissue Engineering of Liaoning Province, Jinzhou Medical University, Jinzhou 121001, China; College of Biomedical Engineering & the Key Laboratory for Medical Functional Nanomaterials, Jining Medical University, Jining 272067, China
| | - Zaifang Li
- China-Australia Institute for Advanced Materials and Manufacturing (IAMM), Jiaxing University, Jiaxing 314001, China.
| | - Guannan Wang
- College of Pharmacy & the Key Laboratory for Medical Tissue Engineering of Liaoning Province, Jinzhou Medical University, Jinzhou 121001, China; College of Biomedical Engineering & the Key Laboratory for Medical Functional Nanomaterials, Jining Medical University, Jining 272067, China.
| |
Collapse
|
46
|
Jing A, Xu Q, Feng W, Liang G. An Electrochemical Immunosensor for Sensitive Detection of the Tumor Marker Carcinoembryonic Antigen (CEA) Based on Three-Dimensional Porous Nanoplatinum/Graphene. MICROMACHINES 2020; 11:mi11070660. [PMID: 32635249 PMCID: PMC7407820 DOI: 10.3390/mi11070660] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Accepted: 06/30/2020] [Indexed: 12/18/2022]
Abstract
Carcinoembryonic antigen (CEA) is an important broad-spectrum tumor marker. The quantitative detection of a low concentration of CEA has important medical significance. In this study, three-dimensional porous graphene-oxide-supported platinum metal nanoparticles (3DPt/HGO) composites were prepared by a wet chemical method and modified on an electrode with enhanced conductivity, a large surface area, and good adsorption of immobilizing antibodies (Ab1). Horseradish peroxidase (HRP)-functionalized Au nanoparticles were fabricated to label the secondary antibodies (Ab2). The proposed immunosensor showed a good linear relationship in the range of 0.001–150 ng/mL for CEA and a detection limit of 0.0006 ng/mL. The immunosensor had high sensitivity, good stability and reproducibility, and has great application prospects for the clinical diagnosis of cancer.
Collapse
Affiliation(s)
- Aihua Jing
- School of Medical Technology and Engineering, Henan University of Science and Technology, Luoyang 471023, China; (A.J.); (Q.X.); (W.F.)
| | - Qiong Xu
- School of Medical Technology and Engineering, Henan University of Science and Technology, Luoyang 471023, China; (A.J.); (Q.X.); (W.F.)
| | - Wenpo Feng
- School of Medical Technology and Engineering, Henan University of Science and Technology, Luoyang 471023, China; (A.J.); (Q.X.); (W.F.)
| | - Gaofeng Liang
- Medical College, Henan University of Science and Technology, Luoyang 471023, China
- Correspondence: ; Tel.: (+86)-0379-64162573
| |
Collapse
|
47
|
Peñalver R, Campillo N, López-García I, Hernández-Córdoba M. Solid-phase microextraction for the determination of iron organic compounds in seawaters and soils by gas chromatography coupled to microwave-induced plasma with atomic emission detection spectrometry. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104630] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
48
|
Li W, Ma C, Song Y, Hong C, Qiao X, Yin B. Sensitive detection of carcinoembryonic antigen (CEA) by a sandwich-type electrochemical immunosensor using MOF-Ce@HA/Ag-HRP-Ab 2 as a nanoprobe. NANOTECHNOLOGY 2020; 31:185605. [PMID: 31995543 DOI: 10.1088/1361-6528/ab70d3] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Sandwich-type electrochemical immunosensor was one of the main methods for detecting carcinoembryonic antigen (CEA). In this work, using Ce-MoF as the skeleton precursor, hyaluronic acid (HA) was coated on the surface of Ce-metal organic framework (Ce-MoF), which loaded with silver nanoparticles (Ag NPs) and horseradish peroxidase (HRP) to catalyze H2O2 and double amplified the current signal. Thus, a sensitive sandwich-type electrochemical immunosensor (Ce-MoF@ HA/Ag-HRP) was designed to detect carcinoembryonic antigen (CEA). The designed immunosensor used Au NPs to enhance the ability of attach more the first antibody (Ab1). This was due to Au NPs had good electrical conductivity and biocompatibility to accelerate electron transfer on the surface of the electrode. HA was riched in -COOH, -OH and had excellent biocompatibility, which can carry more Ag NPs to catalyze H2O2. Finally, the prepared sandwich-type electrochemical immunosensor had excellent biocompatibility and great catalytic performance. The immunosensor can be tested within 30 min and the logarithm of the current signal and CEA concentration showed a broad linear response range of 1 pg ml-1-80 ng ml-1, and the detection limit of CEA was 0.2 pg ml-1. More importantly, the proposed immunosensor had good reproducibility, selectivity, stability and without matrix effect. This confirmed that the proposed immunosensor had broad prospects in early clinical trials.
Collapse
Affiliation(s)
- Wenjun Li
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Production and Construction Corps, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, People's Republic of China
| | | | | | | | | | | |
Collapse
|
49
|
Hyper-cross-linked β-cyclodextrin nanosponge: a three-dimensional, porous and biodegradable catalyst in the one-pot synthesis of kojic acid-based heterocyclic compounds. RESEARCH ON CHEMICAL INTERMEDIATES 2020. [DOI: 10.1007/s11164-019-04067-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
50
|
A sandwich-type electrochemical immunosensor for detecting CEA based on CeO2-MoS2 absorbed Pb2+. Anal Biochem 2020; 592:113566. [DOI: 10.1016/j.ab.2019.113566] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 12/17/2019] [Accepted: 12/22/2019] [Indexed: 01/07/2023]
|