1
|
Laomeephol C, Tawinwung S, Suppipat K, Arunmanee W, Wang Q, Amie Luckanagul J. Surface functionalization of virus-like particles via bioorthogonal click reactions for enhanced cell-specific targeting. Int J Pharm 2024; 660:124332. [PMID: 38866085 DOI: 10.1016/j.ijpharm.2024.124332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Revised: 05/27/2024] [Accepted: 06/09/2024] [Indexed: 06/14/2024]
Abstract
Surface functionalization of nano drug carriers allows for precise delivery of therapeutic molecules to the target site. This technique involves attaching targeting molecules to the nanoparticle surface, facilitating selective interaction. In this study, we engineered virus-like particles (VLPs) to enhance their targeting capabilities. Azide groups incorporated on the lipid membranes of VLPs enabled bioorthogonal click reactions for conjugation with cycloalkyne-bearing molecules, providing efficient conjugation with high specificity. HIV-1 Gag VLPs were chosen due to their envelope, which allows host membrane component incorporation, and the Gag protein, which serves as a recognition motif for human T cells. This combination, along with antibody-mediated targeting, addresses the limitations of intracellular delivery to T cells, which typically exhibit low uptake of exogenous materials. The selective uptake of azide VLPs by CD3-positive T cells was evaluated in a co-culture system. Even without antibody conjugation, VLP uptake was enhanced in T cells, indicating their intrinsic targeting potential. Antibody conjugation further amplified this effect, demonstrating the synergistic benefits of the combined targeting approach. Our study shows that recombinant production of azide functionalized VLPs results in engineered nanoparticles that can be easily modified using bioorthogonal click reactions, providing high specificity and versatility for conjugation with various molecules, making it applicable to a wide range of biological products.
Collapse
Affiliation(s)
- Chavee Laomeephol
- Department of Biochemistry and Microbiology, Faculty of Pharmaceutical Sciences, Chulalongkorn University, Bangkok 10330, Thailand; Center of Excellence in Biomaterial Engineering in Medical and Health, Chulalongkorn University, Bangkok 10330, Thailand
| | - Supannikar Tawinwung
- Department of Pharmacology and Physiology, Faculty of Pharmaceutical Sciences, Chulalongkorn University, Bangkok 10330, Thailand; Cellular Immunotherapy Research Unit, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand
| | - Koramit Suppipat
- Cellular Immunotherapy Research Unit, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand; Department of Research Affairs, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand
| | - Wanatchaporn Arunmanee
- Department of Biochemistry and Microbiology, Faculty of Pharmaceutical Sciences, Chulalongkorn University, Bangkok 10330, Thailand
| | - Qian Wang
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208, USA
| | - Jittima Amie Luckanagul
- Center of Excellence in Biomaterial Engineering in Medical and Health, Chulalongkorn University, Bangkok 10330, Thailand; Department of Pharmaceutics and Industrial Pharmacy, Faculty of Pharmaceutical Sciences, Chulalongkorn University, Bangkok 10330, Thailand; Center of Excellence in Plant-produced Pharmaceuticals, Chulalongkorn University, Bangkok 10330, Thailand.
| |
Collapse
|
2
|
McCormick RA, Ralbovsky NM, Gilbraith W, Smith JP, Booksh KS. Analyzing atomic force microscopy images of virus-like particles by expectation-maximization. NPJ Vaccines 2024; 9:112. [PMID: 38902288 PMCID: PMC11190231 DOI: 10.1038/s41541-024-00871-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Accepted: 03/28/2024] [Indexed: 06/22/2024] Open
Abstract
Analysis of virus-like particles (VLPs) is an essential task in optimizing their implementation as vaccine antigens for virus-initiated diseases. Interrogating VLP collections for elasticity by probing with a rigid atomic force microscopy (AFM) tip is a potential method for determining VLP morphological changes. During VLP morphological change, it is not expected that all VLPs would be in the same state. This leads to the open question of whether VLPs may change in a continuous or stepwise fashion. For continuous change, the statistical distribution of observed VLP properties would be expected as a single distribution, while stepwise change would lead to a multimodal distribution of properties. This study presents the application of a Gaussian mixture model (GMM), fit by the Expectation-Maximization (EM) algorithm, to identify different states of VLP morphological change observed by AFM imaging.
Collapse
Affiliation(s)
- Rachel A McCormick
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE, 19716, USA
| | - Nicole M Ralbovsky
- Analytical Research & Development, MRL, Merck & Co., Inc, West Point, PA, 19486, USA
| | - William Gilbraith
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE, 19716, USA
| | - Joseph P Smith
- Process Research & Development, MRL, Merck & Co., Inc, West Point, PA, 19486, USA.
| | - Karl S Booksh
- Department of Chemistry and Biochemistry, University of Delaware, Newark, DE, 19716, USA.
| |
Collapse
|
3
|
Sun W, Qian J, Li Y, Chen Y, Dou Z, Lin R, Cheng P, Gao X, Yuan Q, Hu Y. Enhancing higher-order modal response in multifrequency atomic force microscopy with a coupled cantilever system. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2024; 15:694-703. [PMID: 38919165 PMCID: PMC11196946 DOI: 10.3762/bjnano.15.57] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 05/27/2024] [Indexed: 06/27/2024]
Abstract
Multifrequency atomic force microscopy (AFM) utilizes the multimode operation of cantilevers to achieve rapid high-resolution imaging and extract multiple properties. However, the higher-order modal response of traditional rectangular cantilever is weaker in air, which affects the sensitivity of multifrequency AFM detection. To address this issue, we previously proposed a bridge/cantilever coupled system model to enhance the higher-order modal response of the cantilever. This model is simpler and less costly than other enhancement methods, making it easier to be widely used. However, previous studies were limited to theoretical analysis and preliminary simulations regarding ideal conditions. In this paper, we undertake a more comprehensive investigation of the coupled system, taking into account the influence of probe and excitation surface sizes on the modal response. To facilitate the exploration of the effectiveness and optimal conditions for the coupled system in practical applications, a macroscale experimental platform is established. By conducting finite element analysis and experiments, we compare the performance of the coupled system with that of traditional cantilevers and quantify the enhancement in higher-order modal response. Also, the optimal conditions for the enhancement of macroscale cantilever modal response are explored. Additionally, we also supplement the characteristics of this model, including increasing the modal frequency of the original cantilever and generating additional resonance peaks, demonstrating the significant potential of the coupled system in various fields of AFM.
Collapse
Affiliation(s)
- Wendong Sun
- School of Physics, Beihang University, Beijing 100191, P.R. China
| | - Jianqiang Qian
- School of Physics, Beihang University, Beijing 100191, P.R. China
| | - Yingzi Li
- School of Physics, Beihang University, Beijing 100191, P.R. China
| | - Yanan Chen
- School of Physics, Beihang University, Beijing 100191, P.R. China
| | - Zhipeng Dou
- State Key Laboratory of Catalysis, CAS Center for Excellence in Nanoscience, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, P. R. China
| | - Rui Lin
- School of Physics, Beihang University, Beijing 100191, P.R. China
| | - Peng Cheng
- School of Physics, Beihang University, Beijing 100191, P.R. China
| | - Xiaodong Gao
- School of Physics, Beihang University, Beijing 100191, P.R. China
| | - Quan Yuan
- School of Physics, Beihang University, Beijing 100191, P.R. China
| | - Yifan Hu
- School of Physics, Beihang University, Beijing 100191, P.R. China
| |
Collapse
|
4
|
Chiodini S, Borbone F, Oscurato SL, Garcia PD, Ambrosio A. Light-induced modulation of viscoelastic properties in azobenzene polymers. NANOPHOTONICS 2024; 13:229-238. [PMID: 38283896 PMCID: PMC10808048 DOI: 10.1515/nanoph-2023-0728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 12/21/2023] [Indexed: 01/30/2024]
Abstract
Photo-induced isomerization of azobenzene molecules drives mass migrations in azopolymer samples. The resulting macroscopic directional photo-deformation of the material morphology has found many applications in literature, although the fundamental mechanisms behind this mass transfer are still under debate. Hence, it is of paramount importance to find quantitative observables that could drive the community toward a better understanding of this phenomenon. In this regard, azopolymer mechanical properties have been intensively studied, but the lack of a nanoscale technique capable of quantitative viscoelastic measurements has delayed the progress in the field. Here, we use bimodal atomic force microscopy (AFM) as a powerful technique for nanomechanical characterizations of azopolymers. With this multifrequency AFM approach, we map the azopolymer local elasticity and viscosity, with high resolution, after irradiation. We find that, while in the (previously) illuminated region, a general photo-softening is measured; locally, the Young modulus and the viscosity depend upon the inner structuring of the illuminating light spot. We then propose a possible interpretation based on a light-induced expansion plus a local alignment of the polymer chains (directional hole-burning effect), which explains the experimental observations. The possibility to access, in a reliable and quantitative way, both Young modulus and viscosity could trigger new theoretical-numerical investigations on the azopolymer mass migration dynamics since, as we show, both parameters can be considered measurable. Furthermore, our results provide a route for engineering the nanomechanical properties of azopolymers, which could find interesting applications in cell mechanobiology research.
Collapse
Affiliation(s)
- Stefano Chiodini
- Center for Nano Science and Technology, Fondazione Istituto Italiano di Tecnologia, Via Rubattino 81, 20134, Milan, Italy
| | - Fabio Borbone
- Department of Chemical Sciences, University of Naples “Federico II”, Via Cinthia Complesso Universitario di Monte Sant’Angelo, Via Cintia, 80126Naples, Italy
| | - Stefano L. Oscurato
- Center for Nano Science and Technology, Fondazione Istituto Italiano di Tecnologia, Via Rubattino 81, 20134, Milan, Italy
- Physics Department “E. Pancini”, University of Naples “Federico II”, Via Cinthia Complesso Universitario di Monte Sant’Angelo, Via Cintia, 80126Naples, Italy
| | - Pablo D. Garcia
- BYM-Ingema, Centro de Empresas del Caudal, Polígono Vega de Arriba, 33600, Mieres, Spain
| | - Antonio Ambrosio
- Center for Nano Science and Technology, Fondazione Istituto Italiano di Tecnologia, Via Rubattino 81, 20134, Milan, Italy
| |
Collapse
|
5
|
Zhdanov DD, Ivin YY, Shishparenok AN, Kraevskiy SV, Kanashenko SL, Agafonova LE, Shumyantseva VV, Gnedenko OV, Pinyaeva AN, Kovpak AA, Ishmukhametov AA, Archakov AI. Perspectives for the creation of a new type of vaccine preparations based on pseudovirus particles using polio vaccine as an example. BIOMEDITSINSKAIA KHIMIIA 2023; 69:253-280. [PMID: 37937429 DOI: 10.18097/pbmc20236905253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2023]
Abstract
Traditional antiviral vaccines are currently created by inactivating the virus chemically, most often using formaldehyde or β-propiolactone. These approaches are not optimal since they negatively affect the safety of the antigenic determinants of the inactivated particles and require additional purification stages. The most promising platforms for creating vaccines are based on pseudoviruses, i.e., viruses that have completely preserved the outer shell (capsid), while losing the ability to reproduce owing to the destruction of the genome. The irradiation of viruses with electron beam is the optimal way to create pseudoviral particles. In this review, with the example of the poliovirus, the main algorithms that can be applied to characterize pseudoviral particles functionally and structurally in the process of creating a vaccine preparation are presented. These algorithms are, namely, the analysis of the degree of genome destruction and coimmunogenicity. The structure of the poliovirus and methods of its inactivation are considered. Methods for assessing residual infectivity and immunogenicity are proposed for the functional characterization of pseudoviruses. Genome integrity analysis approaches, atomic force and electron microscopy, surface plasmon resonance, and bioelectrochemical methods are crucial to structural characterization of the pseudovirus particles.
Collapse
Affiliation(s)
- D D Zhdanov
- Institute of Biomedical Chemistry, Moscow, Russia
| | - Yu Yu Ivin
- Institute of Biomedical Chemistry, Moscow, Russia; Chumakov Federal Scientific Center for Research and Development of Immune-and-Biological Products of Russian Academy of Sciences, Moscow, Russia
| | | | | | | | | | - V V Shumyantseva
- Institute of Biomedical Chemistry, Moscow, Russia; Pirogov Russian National Research Medical University, Moscow, Russia
| | - O V Gnedenko
- Institute of Biomedical Chemistry, Moscow, Russia
| | - A N Pinyaeva
- Institute of Biomedical Chemistry, Moscow, Russia; Chumakov Federal Scientific Center for Research and Development of Immune-and-Biological Products of Russian Academy of Sciences, Moscow, Russia
| | - A A Kovpak
- Institute of Biomedical Chemistry, Moscow, Russia
| | - A A Ishmukhametov
- Chumakov Federal Scientific Center for Research and Development of Immune-and-Biological Products of Russian Academy of Sciences, Moscow, Russia
| | - A I Archakov
- Institute of Biomedical Chemistry, Moscow, Russia; Pirogov Russian National Research Medical University, Moscow, Russia
| |
Collapse
|
6
|
Ukraintsev E, Rezek B. Non-contact non-resonant atomic force microscopy method for measurements of highly mobile molecules and nanoparticles. Ultramicroscopy 2023; 253:113816. [PMID: 37531754 DOI: 10.1016/j.ultramic.2023.113816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 04/13/2023] [Accepted: 07/25/2023] [Indexed: 08/04/2023]
Abstract
Atomic force microscopy (AFM) is nowadays indispensable versatile scanning probe method widely employed for fundamental and applied research in physics, chemistry, biology as well as industrial metrology. Conventional AFM systems can operate in various environments such as ultra-high vacuum, electrolyte solutions, or controlled gas atmosphere. Measurements in ambient air are prevalent due to their technical simplicity; however, there are drawbacks such as formation of water meniscus that greatly increases attractive interaction (adhesion) between the tip and the sample, reduced spatial resolution, and too strong interactions leading to tip and/or sample modifications. Here we show how the attractive forces in AFM under ambient conditions can be used with advantage to probe surface properties in a very sensitive way even on highly mobile molecules and nanoparticles. We introduce a stable non-contact non-resonant (NCNR) AFM method which enables to reliably perform measurements in the attractive force regime even in air by controlling the tip position in the intimate surface vicinity without touching it. We demonstrate proof-of-concept results on helicene-based macrocycles, DNA on mica, and nanodiamonds on SiO2. We compare the results with other conventional AFM regimes, showing NCNR advantages such as higher spatial resolution, reduced tip contamination, and negligible sample modification. We analyze principle physical and chemical mechanisms influencing the measurements, discuss issues of stability and various possible method implementations. We explain how the NCNR method can be applied in any AFM system by a mere software modification. The method thus opens a new research field for measurements of highly sensitive and mobile nanoscale objects under air and other environments.
Collapse
Affiliation(s)
- Egor Ukraintsev
- Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, Prague 6, 166 27, Czech Republic.
| | - Bohuslav Rezek
- Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, Prague 6, 166 27, Czech Republic
| |
Collapse
|
7
|
Martins SA, Santos J, Silva RDM, Rosa C, Cabo Verde S, Correia JDG, Melo R. How promising are HIV-1-based virus-like particles for medical applications. Front Cell Infect Microbiol 2022; 12:997875. [PMID: 36275021 PMCID: PMC9585283 DOI: 10.3389/fcimb.2022.997875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 09/23/2022] [Indexed: 11/26/2022] Open
Abstract
New approaches aimed at identifying patient-specific drug targets and addressing unmet clinical needs in the framework of precision medicine are a strong motivation for researchers worldwide. As scientists learn more about proteins that drive known diseases, they are better able to design promising therapeutic approaches to target those proteins. The field of nanotechnology has been extensively explored in the past years, and nanoparticles (NPs) have emerged as promising systems for target-specific delivery of drugs. Virus-like particles (VLPs) arise as auspicious NPs due to their intrinsic properties. The lack of viral genetic material and the inability to replicate, together with tropism conservation and antigenicity characteristic of the native virus prompted extensive interest in their use as vaccines or as delivery systems for therapeutic and/or imaging agents. Owing to its simplicity and non-complex structure, one of the viruses currently under study for the construction of VLPs is the human immunodeficiency virus type 1 (HIV-1). Typically, HIV-1-based VLPs are used for antibody discovery, vaccines, diagnostic reagent development and protein-based assays. This review will be centered on the use of HIV-1-based VLPs and their potential biomedical applications.
Collapse
Affiliation(s)
- Sofia A. Martins
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - Joana Santos
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - Rúben D. M. Silva
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - Cátia Rosa
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - Sandra Cabo Verde
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
- Departamento de Engenharia e Ciências Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - João D. G. Correia
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
- Departamento de Engenharia e Ciências Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - Rita Melo
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| |
Collapse
|
8
|
Eid J, Socol M, Naillon A, Feuillard J, Ciandrini L, Margeat E, Charlot B, Mougel M. Viro-fluidics: Real-time analysis of virus production kinetics at the single-cell level. BIOPHYSICAL REPORTS 2022; 2:100068. [PMID: 36425325 PMCID: PMC9680794 DOI: 10.1016/j.bpr.2022.100068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Accepted: 08/05/2022] [Indexed: 06/16/2023]
Abstract
Real-time visualization and quantification of viruses released by a cell are crucial to further decipher infection processes. Kinetics studies at the single-cell level will circumvent the limitations of bulk assays with asynchronous virus replication. We have implemented a "viro-fluidic" method, which combines microfluidics and virology at single-cell and single-virus resolutions. As an experimental model, we used standard cell lines producing fluorescent HIV-like particles (VLPs). First, to scale the strategy to the single-cell level, we validated a sensitive flow virometry system to detect VLPs in low concentration samples (≥104 VLPs/mL). Then, this system was coupled to a single-cell trapping device to monitor in real-time the VLPs released, one at a time, from single cells under cell culture conditions. Our results revealed an average production rate of 50 VLPs/h/cell similar to the rate estimated for the same cells grown in population. Thus, the virus-producing capacities of the trapped cells were preserved and its real-time monitoring was accurate. Moreover, single-cell analysis revealed a release of VLPs with stochastic bursts with typical time intervals of few minutes, revealing the existence of limiting step(s) in the virus biogenesis process. Our tools can be applied to other pathogens or to extracellular vesicles to elucidate the dissemination mechanisms of these biological nanoparticles.
Collapse
Affiliation(s)
- Joëlle Eid
- Team R2D2: Retroviral RNA Dynamics and Delivery, IRIM, UMR9004, CNRS, University of Montpellier, Montpellier, France
| | - Marius Socol
- Team R2D2: Retroviral RNA Dynamics and Delivery, IRIM, UMR9004, CNRS, University of Montpellier, Montpellier, France
| | - Antoine Naillon
- Université Grenoble Alpes, CNRS, Grenoble INP, 3SR, Grenoble, France
| | - Jérôme Feuillard
- Team R2D2: Retroviral RNA Dynamics and Delivery, IRIM, UMR9004, CNRS, University of Montpellier, Montpellier, France
| | - Luca Ciandrini
- CBS, Université de Montpellier, CNRS, INSERM, Montpellier, France
| | - Emmanuel Margeat
- CBS, Université de Montpellier, CNRS, INSERM, Montpellier, France
| | - Benoit Charlot
- IES, Université de Montpellier, CNRS, Montpellier, France
| | - Marylène Mougel
- Team R2D2: Retroviral RNA Dynamics and Delivery, IRIM, UMR9004, CNRS, University of Montpellier, Montpellier, France
| |
Collapse
|
9
|
Gisbert VG, Garcia R. Accurate Wide-Modulus-Range Nanomechanical Mapping of Ultrathin Interfaces with Bimodal Atomic Force Microscopy. ACS NANO 2021; 15:20574-20581. [PMID: 34851086 DOI: 10.1021/acsnano.1c09178] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The nanoscale determination of the mechanical properties of interfaces is of paramount relevance in materials science and cell biology. Bimodal atomic force microscopy (AFM) is arguably the most advanced nanoscale method for mapping the elastic modulus of interfaces. Simulations, theory, and experiments have validated bimodal AFM measurements on thick samples (from micrometer to millimeter). However, the bottom-effect artifact, this is, the influence of the rigid support on the determination of the Young's modulus, questions its accuracy for ultrathin materials and interfaces (1-15 nm). Here we develop a bottom-effect correction method that yields the intrinsic Young's modulus value of a material independent of its thickness. Experiments and numerical simulations validate the accuracy of the method for a wide range of materials (1 MPa to 100 GPa). Otherwise, the Young's modulus of an ultrathin material might be overestimated by a 10-fold factor.
Collapse
Affiliation(s)
- Victor G Gisbert
- Instituto de Ciencia de Materiales de Madrid, CSIC, c/Sor Juana Inés de la Cruz 3, 28049 Madrid, Spain
| | - Ricardo Garcia
- Instituto de Ciencia de Materiales de Madrid, CSIC, c/Sor Juana Inés de la Cruz 3, 28049 Madrid, Spain
| |
Collapse
|
10
|
Dou Z, Qian J, Li Y, Lin R, Wang T, Wang J, Cheng P, Xu Z. Enhancing higher-order eigenmodes of AFM using bridge/cantilever coupled system. Micron 2021; 150:103147. [PMID: 34534920 DOI: 10.1016/j.micron.2021.103147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 08/28/2021] [Accepted: 09/05/2021] [Indexed: 11/18/2022]
Abstract
The wide application of multi-frequency atomic force microscopy (AFM) places higher demands on the higher-order modes response of the cantilever. The response of the higher modes however is generally weaker than that of the fundamental mode in air. Researchers have proposed many methods, most of which involve cantilever modification, to enhance higher-order eigenmodes response. These previous results are proved to be effective, but the microfabrication is expensive. In this article, we propose a novel model based on bridge/cantilever coupled system to enhance the higher-order modes response of AFM cantilever. The segmented beam model provides a new thinking to explain the appearance of undesired peaks in mode analysis of cantilever. Through theoretical analysis and simulation, we find that higher resonance modes are enhanced by tuning the bridge to match the high resonances of the single clamped cantilever. The length, thickness of the coupled system and the location of excitation can affect the enhancement. In summary, this model provides a new way to improve higher mode response for multi-frequency and other high bandwidth applications of AFM.
Collapse
Affiliation(s)
- Zhipeng Dou
- School of Physics, Beihang University, Beijing 100083, China
| | - Jianqiang Qian
- School of Physics, Beihang University, Beijing 100083, China.
| | - Yingzi Li
- School of Physics, Beihang University, Beijing 100083, China
| | - Rui Lin
- School of Physics, Beihang University, Beijing 100083, China
| | - Tingwei Wang
- School of Physics, Beihang University, Beijing 100083, China
| | - Jianhai Wang
- School of Physics, Beihang University, Beijing 100083, China
| | - Peng Cheng
- School of Physics, Beihang University, Beijing 100083, China
| | - Zeyu Xu
- School of Physics, Beihang University, Beijing 100083, China
| |
Collapse
|
11
|
Chimeric VLPs Based on HIV-1 Gag and a Fusion Rabies Glycoprotein Induce Specific Antibodies against Rabies and Foot-and-Mouth Disease Virus. Vaccines (Basel) 2021; 9:vaccines9030251. [PMID: 33809060 PMCID: PMC7999769 DOI: 10.3390/vaccines9030251] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 03/07/2021] [Accepted: 03/08/2021] [Indexed: 12/25/2022] Open
Abstract
Foot and mouth disease is a livestock acute disease, causing economic losses in affected areas. Currently, control of this disease is performed by mandatory vaccination campaigns using inactivated viral vaccines. In this work, we describe the development of a chimeric VLP-based vaccine candidate for foot-and-mouth disease virus (FMDV), based on the co-expression of the HIV-1 Gag protein and a novel fusion rabies glycoprotein (RVG), which carries in its N-term the FMDV main antigen: the G-H loop. It is demonstrated by confocal microscopy that both Gag-GFP polyprotein and the G-H loop colocalize at the cell membrane and, that the Gag polyprotein of the HIV virus acts as a scaffold for enveloped VLPs that during the budding process acquires the proteins that are being expressed in the cell membrane. The obtained VLPs were spherical particles of 130 ± 40 nm in diameter (analyzed by TEM, Cryo-TEM and NTA) carrying an envelope membrane that efficiently display the GH-RVG on its surface (analyzed by gold immunolabeling). Immunostainings with a FMDV hyperimmune serum showed that the heterologous antigenic site, genetically fused to RVG, is recognized by specific G-H loop antibodies. Additionally, the cVLPs produced expose the G-H loop to the liquid surrounding (analyzed by specific ELISA). Finally, we confirmed that these FMD cVLPs are able to induce a specific humoral immune response, based on antibodies directed to the G-H loop in experimental animals.
Collapse
|
12
|
Gisbert VG, Amo CA, Jaafar M, Asenjo A, Garcia R. Quantitative mapping of magnetic properties at the nanoscale with bimodal AFM. NANOSCALE 2021; 13:2026-2033. [PMID: 33449980 DOI: 10.1039/d0nr08662b] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
We demonstrate that a force microscope operated in a bimodal configuration enables the mapping of magnetic interactions with high quantitative accuracy and high-spatial resolution (∼30 nm). Bimodal AFM operation doubles the number of observables with respect to conventional magnetic force microscopy methods which enables to determine quantitatively in a single processing step several magnetic properties. The theory of bimodal AFM provides analytical expressions for different magnetic force models, in particular those characterized by power-law and exponential distance dependences. Bimodal AFM provides a self-evaluation protocol to test the accuracy of the measurements. The agreement obtained between the experiments and theory for two different magnetic samples support the application of bimodal AFM to map quantitatively long-range magnetic interactions.
Collapse
Affiliation(s)
- Victor G Gisbert
- Instituto de Ciencia de Materiales de Madrid, CSIC, c/Sor Juana Inés de la Cruz 3, 28049 Madrid, Spain
| | | | | | | | | |
Collapse
|
13
|
Garcia R. Nanomechanical mapping of soft materials with the atomic force microscope: methods, theory and applications. Chem Soc Rev 2020; 49:5850-5884. [PMID: 32662499 DOI: 10.1039/d0cs00318b] [Citation(s) in RCA: 161] [Impact Index Per Article: 40.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
Fast, high-resolution, non-destructive and quantitative characterization methods are needed to develop materials with tailored properties at the nanoscale or to understand the relationship between mechanical properties and cell physiology. This review introduces the state-of-the-art force microscope-based methods to map at high-spatial resolution the elastic and viscoelastic properties of soft materials. The experimental methods are explained in terms of the theories that enable the transformation of observables into material properties. Several applications in materials science, molecular biology and mechanobiology illustrate the scope, impact and potential of nanomechanical mapping methods.
Collapse
Affiliation(s)
- Ricardo Garcia
- Instituto de Ciencia de Materiales de Madrid, CSIC, c/Sor Juana Inés de la Cruz 3, 28049 Madrid, Spain.
| |
Collapse
|
14
|
González-Domínguez I, Puente-Massaguer E, Cervera L, Gòdia F. Quantification of the HIV-1 virus-like particle production process by super-resolution imaging: From VLP budding to nanoparticle analysis. Biotechnol Bioeng 2020; 117:1929-1945. [PMID: 32242921 DOI: 10.1002/bit.27345] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2019] [Revised: 03/17/2020] [Accepted: 03/27/2020] [Indexed: 12/31/2022]
Abstract
Virus-like particles (VLPs) offer great promise in the field of nanomedicine. Enveloped VLPs are a class of these nanoparticles and their production process occurs by a budding process, which is known to be the most critical step at intracellular level. In this study, we developed a novel imaging method based on super-resolution fluorescence microscopy (SRFM) to assess the generation of VLPs in living cells. This methodology was applied to study the production of Gag VLPs in three animal cell platforms of reference: HEK 293-transient gene expression (TGE), High Five-baculovirus expression vector system (BEVS) and Sf9-BEVS. Quantification of the number of VLP assembly sites per cell ranged from 500 to 3,000 in the different systems evaluated. Although the BEVS was superior in terms of Gag polyprotein expression, the HEK 293-TGE platform was more efficient regarding the assembly of Gag as VLPs. This was translated into higher levels of non-assembled Gag monomer in BEVS harvested supernatants. Furthermore, the presence of contaminating nanoparticles was evidenced in all three systems, specifically in High Five cells. The SRFM-based method here developed was also successfully applied to measure the concentration of VLPs in crude supernatants. The lipid membrane of VLPs and the presence of nucleic acids alongside these nanoparticles could also be detected using common staining procedures. Overall, a complete picture of the VLP production process was achieved in these three production platforms. The robustness and sensitivity of this new approach broaden the applicability of SRFM toward the development of new detection, diagnosis and quantification methods based on confocal microscopy in living systems.
Collapse
Affiliation(s)
- Irene González-Domínguez
- Departament d'Enginyeria Química Biològica i Ambiental, Universitat Autònoma de Barcelona, Barcelona, Bellaterra, Spain
| | - Eduard Puente-Massaguer
- Departament d'Enginyeria Química Biològica i Ambiental, Universitat Autònoma de Barcelona, Barcelona, Bellaterra, Spain
| | - Laura Cervera
- Departament d'Enginyeria Química Biològica i Ambiental, Universitat Autònoma de Barcelona, Barcelona, Bellaterra, Spain
| | - Francesc Gòdia
- Departament d'Enginyeria Química Biològica i Ambiental, Universitat Autònoma de Barcelona, Barcelona, Bellaterra, Spain
| |
Collapse
|
15
|
González-Domínguez I, Puente-Massaguer E, Cervera L, Gòdia F. Quality Assessment of Virus-Like Particles at Single Particle Level: A Comparative Study. Viruses 2020; 12:E223. [PMID: 32079288 PMCID: PMC7077327 DOI: 10.3390/v12020223] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2019] [Revised: 02/03/2020] [Accepted: 02/11/2020] [Indexed: 12/16/2022] Open
Abstract
Virus-like particles (VLPs) have emerged as a powerful scaffold for antigen presentation and delivery strategies. Compared to single protein-based therapeutics, quality assessment requires a higher degree of refinement due to the structure of VLPs and their similar properties to extracellular vesicles (EVs). Advances in the field of nanotechnology with single particle and high-resolution analysis techniques provide appealing approaches to VLP characterization. In this study, six different biophysical methods have been assessed for the characterization of HIV-1-based VLPs produced in mammalian and insect cell platforms. Sample preparation and equipment set-up were optimized for the six strategies evaluated. Electron Microscopy (EM) disclosed the presence of several types of EVs within VLP preparations and cryogenic transmission electron microscopy (cryo-TEM) resulted in the best technique to resolve the VLP ultrastructure. The use of super-resolution fluorescence microscopy (SRFM), nanoparticle tracking analysis (NTA) and flow virometry enabled the high throughput quantification of VLPs. Interestingly, differences in the determination of nanoparticle concentration were observed between techniques. Moreover, NTA and flow virometry allowed the quantification of both EVs and VLPs within the same experiment while analyzing particle size distribution (PSD), simultaneously. These results provide new insights into the use of different analytical tools to monitor the production of nanoparticle-based biologicals and their associated contaminants.
Collapse
|
16
|
Signal enhancement on gold nanoparticle-based lateral flow tests using cellulose nanofibers. Biosens Bioelectron 2019; 141:111407. [DOI: 10.1016/j.bios.2019.111407] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 05/30/2019] [Accepted: 06/02/2019] [Indexed: 12/14/2022]
|
17
|
Farzin L, Shamsipur M, Samandari L, Sheibani S. HIV biosensors for early diagnosis of infection: The intertwine of nanotechnology with sensing strategies. Talanta 2019; 206:120201. [PMID: 31514868 DOI: 10.1016/j.talanta.2019.120201] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 07/30/2019] [Accepted: 07/30/2019] [Indexed: 12/20/2022]
Abstract
Human immunodeficiency virus (HIV) is a lentivirus that leads to acquired immunodeficiency syndrome (AIDS). With increasing awareness of AIDS emerging as a global public health threat, different HIV testing kits have been developed to detect antibodies (Ab) directed toward different parts of HIV. A great limitation of these tests is that they can not detect HIV antibodies during early virus infection. Therefore, to overcome this challenge, a wide range of biosensors have been developed for early diagnosis of HIV infection. A significant amount of these studies have been focused on the application of nanomaterials for improving the sensitivity and accuracy of the sensing methods. Following an introduction into this field, a first section of this review covers the synthesis and applicability of such nanomaterials as metal nanoparticles (NPs), quantum dots (QDs), carbon-based nanomaterials and metal nanoclusters (NCs). A second larger section covers the latest developments concerning nanomaterial-based biosensors for HIV diagnosis, with paying a special attention to the determination of CD4+ cells as a hall mark of HIV infection, HIV gene, HIV p24 core protein, HIV p17 peptide, HIV-1 virus-like particles (VLPs) and HIV related enzymes, particularly those that are passed on from the virus to the CD4+ T lymphocytes and are necessary for viral reproduction within the host cell. These studies are described in detail along with their diverse principles/mechanisms (e.g. electrochemistry, fluorescence, electromagnetic-piezoelectric, surface plasmon resonance (SPR), surface enhanced Raman spectroscopy (SERS) and colorimetry). Despite the significant progress in HIV biosensing in the last years, there is a great need for the development of point-of-care (POC) technologies which are affordable, robust, easy to use, portable, and possessing sufficient quantitative accuracy to enable clinical decision making. In the final section, the focus is on the portable sensing devices as a new standard of POC and personalized diagnostics.
Collapse
Affiliation(s)
- Leila Farzin
- Radiation Application Research School, Nuclear Science and Technology Research Institute, P.O. Box, 11365-3486, Tehran, Iran.
| | - Mojtaba Shamsipur
- Department of Chemistry, Razi University, P.O. Box, 67149-67346, Kermanshah, Iran
| | - Leila Samandari
- Department of Chemistry, Razi University, P.O. Box, 67149-67346, Kermanshah, Iran
| | - Shahab Sheibani
- Radiation Application Research School, Nuclear Science and Technology Research Institute, P.O. Box, 11365-3486, Tehran, Iran
| |
Collapse
|
18
|
Pereira Aguilar P, González-Domínguez I, Schneider TA, Gòdia F, Cervera L, Jungbauer A. At-line multi-angle light scattering detector for faster process development in enveloped virus-like particle purification. J Sep Sci 2019; 42:2640-2649. [PMID: 31169979 PMCID: PMC6771681 DOI: 10.1002/jssc.201900441] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 06/04/2019] [Accepted: 06/04/2019] [Indexed: 12/05/2022]
Abstract
At‐line static light scattering and fluorescence monitoring allows direct in‐process tracking of fluorescent virus‐like particles. We have demonstrated this by coupling at‐line multi‐angle light scattering and fluorescence detectors to the downstream processing of enveloped virus‐like particles. Since light scattering intensity is directly proportional to particle concentration, our strategy allowed a swift identification of product containing fractions and rapid process development. Virus‐like particles containing the Human Immunodeficiency Virus‐1 Gag protein fused to the Green Fluorescence protein were produced in Human Embryonic Kidney 293 cells by transient transfection. A single‐column anion‐exchange chromatography method was used for direct capture and purification. The majority of host‐cell protein impurities passed through the column without binding. Virus‐like particles bound to the column were eluted by linear or step salt gradients. Particles recovered in the step gradient purification were characterized by nanoparticle tracking analysis, size exclusion chromatography coupled to multi‐angle light scattering and fluorescence detectors and transmission electron microscopy. A total recovery of 66% for the fluorescent particles was obtained with a 50% yield in the main product peak. Virus‐like particles were concentrated 17‐fold to final a concentration of 4.45 × 1010 particles/mL. Simple buffers and operation make this process suitable for large scale purposes.
Collapse
Affiliation(s)
| | - Irene González-Domínguez
- Department d'Enginyeria Química Biològica i Ambiental, Universitat Autònoma de Barcelona, Bellaterra, Barcelona, Spain
| | | | - Francesc Gòdia
- Department d'Enginyeria Química Biològica i Ambiental, Universitat Autònoma de Barcelona, Bellaterra, Barcelona, Spain
| | - Laura Cervera
- Department d'Enginyeria Química Biològica i Ambiental, Universitat Autònoma de Barcelona, Bellaterra, Barcelona, Spain
| | - Alois Jungbauer
- Department of Biotechnology, University of Natural Resources and Life Sciences, Vienna, Austria.,Austrian Centre of Industrial Biotechnology, Vienna, Austria
| |
Collapse
|
19
|
Stylianou A, Kontomaris SV, Grant C, Alexandratou E. Atomic Force Microscopy on Biological Materials Related to Pathological Conditions. SCANNING 2019; 2019:8452851. [PMID: 31214274 PMCID: PMC6535871 DOI: 10.1155/2019/8452851] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 02/23/2019] [Accepted: 03/07/2019] [Indexed: 05/16/2023]
Abstract
Atomic force microscopy (AFM) is an easy-to-use, powerful, high-resolution microscope that allows the user to image any surface and under any aqueous condition. AFM has been used in the investigation of the structural and mechanical properties of a wide range of biological matters including biomolecules, biomaterials, cells, and tissues. It provides the capacity to acquire high-resolution images of biosamples at the nanoscale and allows at readily carrying out mechanical characterization. The capacity of AFM to image and interact with surfaces, under physiologically relevant conditions, is of great importance for realistic and accurate medical and pharmaceutical applications. The aim of this paper is to review recent trends of the use of AFM on biological materials related to health and sickness. First, we present AFM components and its different imaging modes and we continue with combined imaging and coupled AFM systems. Then, we discuss the use of AFM to nanocharacterize collagen, the major fibrous protein of the human body, which has been correlated with many pathological conditions. In the next section, AFM nanolevel surface characterization as a tool to detect possible pathological conditions such as osteoarthritis and cancer is presented. Finally, we demonstrate the use of AFM for studying other pathological conditions, such as Alzheimer's disease and human immunodeficiency virus (HIV), through the investigation of amyloid fibrils and viruses, respectively. Consequently, AFM stands out as the ideal research instrument for exploring the detection of pathological conditions even at very early stages, making it very attractive in the area of bio- and nanomedicine.
Collapse
Affiliation(s)
- Andreas Stylianou
- Cancer Biophysics Laboratory, Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia 2238, Cyprus
| | - Stylianos-Vasileios Kontomaris
- Mobile Radio Communications Laboratory, School of Electrical and Computer Engineering, National Technical University of Athens, Iroon Polytechniou, Athens 15780, Greece
- Athens Metropolitan College, Sorou 74, Marousi 15125, Greece
| | - Colin Grant
- Hitachi High-Technologies Europe, Techspace One, Keckwick Lane, Warrington WA4 4AB, UK
| | - Eleni Alexandratou
- Biomedical Optics and Applied Biophysics Laboratory, School of Electrical and Computer Engineering, National Technical University of Athens, Iroon Polytechniou, Athens 15780, Greece
| |
Collapse
|
20
|
Benaglia S, Gisbert VG, Perrino AP, Amo CA, Garcia R. Fast and high-resolution mapping of elastic properties of biomolecules and polymers with bimodal AFM. Nat Protoc 2018; 13:2890-2907. [DOI: 10.1038/s41596-018-0070-1] [Citation(s) in RCA: 56] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
21
|
Evans CT, Payton O, Picco L, Allen MJ. Algal Viruses: The (Atomic) Shape of Things to Come. Viruses 2018; 10:E490. [PMID: 30213102 PMCID: PMC6165301 DOI: 10.3390/v10090490] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 08/30/2018] [Accepted: 09/07/2018] [Indexed: 01/15/2023] Open
Abstract
Visualization of algal viruses has been paramount to their study and understanding. The direct observation of the morphological dynamics of infection is a highly desired capability and the focus of instrument development across a variety of microscopy technologies. However, the high temporal (ms) and spatial resolution (nm) required, combined with the need to operate in physiologically relevant conditions presents a significant challenge. Here we present a short history of virus structure study and its relation to algal viruses and highlight current work, concentrating on electron microscopy and atomic force microscopy, towards the direct observation of individual algae⁻virus interactions. Finally, we make predictions towards future algal virus study direction with particular focus on the exciting opportunities offered by modern high-speed atomic force microscopy methods and instrumentation.
Collapse
Affiliation(s)
- Christopher T Evans
- Plymouth Marine Laboratory, Plymouth PL1 3DH, UK.
- Interface Analysis Centre, Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL, UK.
| | - Oliver Payton
- Interface Analysis Centre, Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL, UK.
| | - Loren Picco
- Interface Analysis Centre, Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL, UK.
- Department of Physics, Virginia Commonwealth University, Richmond, VA 23284, USA.
| | - Michael J Allen
- Plymouth Marine Laboratory, Plymouth PL1 3DH, UK.
- College of Life and Environmental Sciences, University of Exeter, Exeter EX4 4QD, UK.
| |
Collapse
|
22
|
Eppell SJ, Feinstein M, Li L, White B, Zypman FR. Signal distortion in atomic force microscopy photodetector. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2017; 88:103703. [PMID: 29092466 DOI: 10.1063/1.5008833] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The frequency-dependent complex impedance of an atomic force microscope photodetector is measured. The inverse problem is solved obtaining the voltage that would have been collected with a hypothetical, perfectly flat-frequency-response photodetector from the experimentally available voltage. This information is used to study the distortion that the true input signal undergoes as it passes through the photodetector on the way to becoming the experimentally measured output signal. It is found that signals with features of interest shorter than 10 μs render noticeable differences between the true and measured raw voltages and forces. Signals with features shorter than 1 μs produce experimentally measured force curves that deviate substantially from the true force curves. A method is proposed for correcting the measured raw voltage signal.
Collapse
Affiliation(s)
- Steven J Eppell
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106, USA
| | - Matthew Feinstein
- Department of Physics, Yeshiva University, Manhattan, New York 10033, USA
| | - Li Li
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106, USA
| | - Brandon White
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106, USA
| | - Fredy R Zypman
- Department of Physics, Yeshiva University, Manhattan, New York 10033, USA
| |
Collapse
|