1
|
Wang R, Zhang Z, Chen X, Zhan L, Xu Z. Research on compound pollution characteristics and health risk evaluation of particulate matter and heavy metals in waste glass recycling process. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 337:122570. [PMID: 37717900 DOI: 10.1016/j.envpol.2023.122570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Revised: 08/11/2023] [Accepted: 09/15/2023] [Indexed: 09/19/2023]
Abstract
Owing to the large amount of waste glass generated, the waste glass recycling base is an indispensable municipal supporting facility of a sustainable city. However, waste glass recycling is a complex process involving stages such as multiple-stage crushing and material sorting. Consequently, waste glass recycling base has a considerable impact on the surrounding environment, such as health risk of particulate matter on workers. In this study, we aimed to perform a comprehensive investigation and analysis of compound pollution characteristics and health risk evaluation of particulate matter and heavy metals generated from waste glass recycling process. Soil, particulate fallout, and glass samples were collected from inside and outside a recycling plant in eastern China. Our findings showed that the waste glass treatment process produces a large amount of air particulate matter, and the PM2.5 and PM10 concentrations can reach 3725 and 4055 μg/m3, respectively, in the production workshop during working hours. Meanwhile, the monitoring results show that the concentration of heavy metals on fine particles is higher compared to coarse particles. The high Zn and Pb concentrations detected in the soil and dustfall were proved to be derived from the glass raw materials. However, health risk assessment and particle deposition modeling in the human respiratory system revealed that heavy metals from the air particulate matter have no significant carcinogenicity or non-carcinogenic risk. The Gaussian dispersion model showed that the impact of particulate matter on the surrounding environment and health of the surrounding residents is minimal. Furthermore, transportation is the major emission link according to the particulate emission calculation, indicating that it is imperative to upgrade and reform the existing processes of waste glass recycling. Taken together, this study provides a scientific basis for the green development of waste glass recycling process and further environmental information regarding waste glass recycling plants.
Collapse
Affiliation(s)
- Ruixue Wang
- Shanghai Innovation Center of Reverse Logistics and Supply Chain, Shanghai Polytechnic University, 2360 Jinhai Road, Shanghai 201209, People's Republic of China; School of Resources and Environmental Engineering, Shanghai Polytechnic University, 2360 Jinhai Road, Shanghai 201209, People's Republic of China.
| | - Zijing Zhang
- Shanghai Innovation Center of Reverse Logistics and Supply Chain, Shanghai Polytechnic University, 2360 Jinhai Road, Shanghai 201209, People's Republic of China; School of Resources and Environmental Engineering, Shanghai Polytechnic University, 2360 Jinhai Road, Shanghai 201209, People's Republic of China.
| | - Xinghua Chen
- Shanghai Innovation Center of Reverse Logistics and Supply Chain, Shanghai Polytechnic University, 2360 Jinhai Road, Shanghai 201209, People's Republic of China; School of Resources and Environmental Engineering, Shanghai Polytechnic University, 2360 Jinhai Road, Shanghai 201209, People's Republic of China.
| | - Lu Zhan
- School of Environmental Science and Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, People's Republic of China.
| | - Zhenming Xu
- School of Environmental Science and Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, People's Republic of China.
| |
Collapse
|
2
|
Dai Y, Xu D, Wang H, Zhang F. CFD Simulations of Ventilation and Interunit Dispersion in Dormitory Complex: A Case Study of Epidemic Outbreak in Shanghai. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:4603. [PMID: 36901611 PMCID: PMC10002394 DOI: 10.3390/ijerph20054603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 02/28/2023] [Accepted: 03/02/2023] [Indexed: 06/18/2023]
Abstract
Since the beginning of March 2022, a new round of COVID-19 outbreaks in Shanghai has led to a sharp increase in the number of infected people. It is important to identify possible pollutant transmission routes and predict potential infection risks for infectious diseases. Therefore, this study investigated the cross-diffusion of pollutants caused by natural ventilation, including external windows and indoor ventilation windows, under three wind directions in a densely populated building environment with the CFD method. In this study, CFD building models were developed based on an actual dormitory complex and surrounding buildings under realistic wind conditions to reproduce the airflow fields and transmission paths of pollutants. This paper adopted the Wells-Riley model to assess the risk of cross-infection. The biggest risk of infection was when a source room was located on the windward side, and the risk of infection in other rooms on the same side as the source room was large in the windward direction. When pollutants were released from room 8, north wind resulted in the highest concentration of pollutants in room 28, reaching 37.8%. This paper summarizes the transmission risks related to the indoor and outdoor environments of compact buildings.
Collapse
Affiliation(s)
| | | | - Haidong Wang
- School of Environment and Architecture, University of Shanghai for Science and Technology, 516 Jungong Rd., Shanghai 200093, China
| | | |
Collapse
|
3
|
Liu Z, Cao H, Hu C, Wu M, Zhang S, He J, Jiang C. Modeling the infection risk and emergency evacuation from bioaerosol leakage around an urban vaccine factory. NPJ CLIMATE AND ATMOSPHERIC SCIENCE 2023; 6:6. [PMID: 36846520 PMCID: PMC9937520 DOI: 10.1038/s41612-023-00342-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 02/08/2023] [Indexed: 06/18/2023]
Abstract
Mounting interest in modeling outdoor diffusion and transmission of bioaerosols due to the prevalence of COVID-19 in the urban environment has led to better knowledge of the issues concerning exposure risk and evacuation planning. In this study, the dispersion and deposition dynamics of bioaerosols around a vaccine factory were numerically investigated under various thermal conditions and leakage rates. To assess infection risk at the pedestrian level, the improved Wells-Riley equation was used. To predict the evacuation path, Dijkstra's algorithm, a derived greedy algorithm based on the improved Wells-Riley equation, was applied. The results show that, driven by buoyancy force, the deposition of bioaerosols can reach 80 m on the windward sidewall of high-rise buildings. Compared with stable thermal stratification, the infection risk of unstable thermal stratification in the upstream portion of the study area can increase by 5.53% and 9.92% under a low and high leakage rate, respectively. A greater leakage rate leads to higher infection risk but a similar distribution of high-risk regions. The present work provides a promising approach for infection risk assessment and evacuation planning for the emergency response to urban bioaerosol leakage.
Collapse
Affiliation(s)
- Zhijian Liu
- School of Energy and Power Engineering, North China Electric Power University, Baoding, 071003 China
| | - Hongwei Cao
- School of Energy and Power Engineering, North China Electric Power University, Baoding, 071003 China
| | - Chenxing Hu
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing, 100081 China
| | - Minnan Wu
- School of Energy and Power Engineering, North China Electric Power University, Baoding, 071003 China
| | - Siqi Zhang
- School of Energy and Power Engineering, North China Electric Power University, Baoding, 071003 China
| | - Junzhou He
- School of Energy and Power Engineering, North China Electric Power University, Baoding, 071003 China
| | - Chuan Jiang
- School of Energy and Power Engineering, North China Electric Power University, Baoding, 071003 China
| |
Collapse
|
4
|
Wu M, Zhang G, Wang L, Liu X, Wu Z. Influencing Factors on Airflow and Pollutant Dispersion around Buildings under the Combined Effect of Wind and Buoyancy-A Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:12895. [PMID: 36232193 PMCID: PMC9566737 DOI: 10.3390/ijerph191912895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 10/07/2022] [Accepted: 10/07/2022] [Indexed: 06/16/2023]
Abstract
With the rapid growth of populations worldwide, air quality has become an increasingly important issue related to the health and safety of city inhabitants. There are quite a few factors that contribute to urban air pollution; the majority of studies examining the issue are concerned with environmental conditions, building geometries, source characteristics and other factors and have used a variety of approaches, from theoretical modelling to experimental measurements and numerical simulations. Among the environmental conditions, solar-radiation-induced buoyancy plays an important role in realistic conditions. The thermal conditions of the ground and building façades directly affect the wind field and pollutant dispersion patterns in the microclimate. The coupling effect of wind and buoyancy on the urban environment are currently hot and attractive research topics. Extensive studies have been devoted to this field, some focused on the street canyon scale, and have found that thermal effects do not significantly affect the main airflow structure in the interior of the street canyon but strongly affect the wind velocity and pollutant concentration at the pedestrian level. Others revealed that the pollutant dispersion routes can be obviously different under various Richardson numbers at the scale of the isolated building. The purpose of this review is therefore to systematically articulate the approaches and research outcomes under the combined effect of wind and buoyancy from the street canyon scale to an isolated building, which should provide some insights into future modelling directions in environmental studies.
Collapse
Affiliation(s)
- Mei Wu
- School of Civil Engineering, Hefei University of Technology, Hefei 230009, China
| | - Guangwei Zhang
- School of Civil Engineering, Hefei University of Technology, Hefei 230009, China
| | - Liping Wang
- School of Civil Engineering, Hefei University of Technology, Hefei 230009, China
| | - Xiaoping Liu
- School of Civil Engineering, Hefei University of Technology, Hefei 230009, China
| | - Zhengwei Wu
- School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230026, China
| |
Collapse
|
5
|
Zhang Y, Wang Y, Wang F, Xu X, Wu X. Numerical investigation on the transmission and dispersion of aerosols in a 7-stories building drainage system. BUILDING AND ENVIRONMENT 2021; 201:108009. [PMID: 34075270 PMCID: PMC8161830 DOI: 10.1016/j.buildenv.2021.108009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 05/14/2021] [Accepted: 05/24/2021] [Indexed: 05/08/2023]
Abstract
In previous reports, the positive SARS-CoV-2 nucleic acid was detected in the fecal samples from confirmed pneumonia patients, suggesting a high probability of the fecal-oral transmission. To date, however, the role played by the drainage system of a high-rise building in the virus transmission is not clear and especially studies on the dynamics mechanism behind is scarce. From this point of view, the present work carries out a computational fluid dynamics (CFD) modeling to investigate the effects of the water seal effectiveness of the floor drain, the negative/positive pressures (P 1 , P 2 ) in the bathroom, temperature differential (ΔT), outside wind velocity (v), the piping fittings and the negative pressure at the cowl (P 3 ) on the transmission of the virus-laden aerosol particles in a drainage system of a typical 7-storeys residential building. The CFD models are first validated by the previous experiments in literature. Numerical results imply that the drainage system might play an essential role to the virus transmission. Then, results indicate that, the leakage risk of the aerosol particles via the floor drain with inefficient water-seal (UFD) mainly exists at the upper floors above the neutral pressure level (NPL). Besides, the negative and positive pressures at the bathroom can enhance and reduce the exposure risk of aerosol particles from the corresponding UFD, respectively. The ΔT increasing does not modify the location of the NPL. Moreover, the exposure risk of aerosol particles can be effectively avoided by the well water-sealed floor drains and/or the presence of a proper negative pressure at the cowl on the top floor. Finally, based on the CFD results, several protection suggestions on the drainage system and human activities are provided.
Collapse
Affiliation(s)
- Yuan Zhang
- School of Environment Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yikang Wang
- School of Environment Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Feifei Wang
- School of Environment Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Xinhua Xu
- School of Environment Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Xiaohui Wu
- School of Environment Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| |
Collapse
|
6
|
Lozinsky CH, Touchie MF. Inter-zonal airflow in multi-unit residential buildings: A review of the magnitude and interaction of driving forces, measurement techniques and magnitudes, and its impact on building performance. INDOOR AIR 2020; 30:1083-1108. [PMID: 32643179 DOI: 10.1111/ina.12712] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 06/15/2020] [Accepted: 06/26/2020] [Indexed: 06/11/2023]
Abstract
Inter-zonal airflows within multi-unit residential buildings (MURBs) have profound impacts on an array of building performance metrics, including energy, indoor air quality (IAQ), fire and acoustical separations, and distribution of ventilation air. Although there are wide-ranging implications, most building codes/standards have yet to incorporate airtightness requirements for interior partitions in large, multi-zone structures, and instead focus primarily on exterior envelope airtightness. Despite the multi-disciplinary nature of the topic, previous reviews have been limited to one domain (eg, energy performance, IAQ, specific test methods). This paper presents a comprehensive summary of the literature on inter-zonal airflow in MURBs including the magnitude and interaction of driving forces; its relevance to/effect on building performance; current code requirements; testing methods; and previous measurements. While considerable efforts have been made in recent years to quantify and control inter-zonal airflows, most measurement techniques are still labor-intensive and disruptive, and there is no framework for how to implement performance-based requirements into building codes and standards. Further research efforts should be focused on refining testing methods and preparing the construction industry for code changes.
Collapse
Affiliation(s)
- Cara H Lozinsky
- Department of Civil and Mineral Engineering, University of Toronto, Toronto, ON, Canada
| | - Marianne F Touchie
- Department of Civil and Mineral Engineering, University of Toronto, Toronto, ON, Canada
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
7
|
Wang J, Huo Q, Zhang T, Wang S, Battaglia F. Numerical investigation of gaseous pollutant cross-transmission for single-sided natural ventilation driven by buoyancy and wind. BUILDING AND ENVIRONMENT 2020; 172:106705. [PMID: 32287994 PMCID: PMC7116971 DOI: 10.1016/j.buildenv.2020.106705] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Revised: 01/28/2020] [Accepted: 01/29/2020] [Indexed: 05/13/2023]
Abstract
Single-sided natural ventilation was numerically investigated to determine the impact of buoyancy and wind on the cross-transmission of pollution by considering six window types commonly found in multistory buildings. The goal of this study was to predict the gaseous pollutant transmission using computational fluid dynamics based on the Reynolds-averaged Navier-Stokes equations and baseline k-ω turbulence equations. The results indicated that ventilation rates generally increased with increasing wind speeds if the effects of buoyancy and wind were not suppressed; however, the re-entry ratio representing the proportion of expelled air re-entering other floors and the corresponding risk of infection decreased. If the source of the virus was on a central floor, the risk of infection was the highest on the floors closest to the source. Different window types were also considered for determining their effectiveness in controlling cross-transmission and infection risk, depending on the source location and driving force (e.g., buoyancy and wind).
Collapse
Affiliation(s)
- Jihong Wang
- School of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian, 116024, China
| | - Qiannan Huo
- School of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian, 116024, China
| | - Tengfei Zhang
- School of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian, 116024, China
| | - Shugang Wang
- School of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian, 116024, China
| | - Francine Battaglia
- Department of Mechanical & Aerospace Engineering, University at Buffalo, 339 Jarvis Hall, Buffalo, NY, 14260, USA
| |
Collapse
|
8
|
Wang J, Huo Q, Zhang T, Wang S, Battaglia F. Numerical investigation of gaseous pollutant cross-transmission for single-sided natural ventilation driven by buoyancy and wind. BUILDING AND ENVIRONMENT 2020. [PMID: 32287994 DOI: 10.1016/j.enbuild.2018.03.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Single-sided natural ventilation was numerically investigated to determine the impact of buoyancy and wind on the cross-transmission of pollution by considering six window types commonly found in multistory buildings. The goal of this study was to predict the gaseous pollutant transmission using computational fluid dynamics based on the Reynolds-averaged Navier-Stokes equations and baseline k-ω turbulence equations. The results indicated that ventilation rates generally increased with increasing wind speeds if the effects of buoyancy and wind were not suppressed; however, the re-entry ratio representing the proportion of expelled air re-entering other floors and the corresponding risk of infection decreased. If the source of the virus was on a central floor, the risk of infection was the highest on the floors closest to the source. Different window types were also considered for determining their effectiveness in controlling cross-transmission and infection risk, depending on the source location and driving force (e.g., buoyancy and wind).
Collapse
Affiliation(s)
- Jihong Wang
- School of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian, 116024, China
| | - Qiannan Huo
- School of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian, 116024, China
| | - Tengfei Zhang
- School of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian, 116024, China
| | - Shugang Wang
- School of Civil Engineering, Dalian University of Technology, 2 Linggong Road, Dalian, 116024, China
| | - Francine Battaglia
- Department of Mechanical & Aerospace Engineering, University at Buffalo, 339 Jarvis Hall, Buffalo, NY, 14260, USA
| |
Collapse
|
9
|
Dai Y, Mak CM, Zhang Y, Cui D, Hang J. Investigation of interunit dispersion in 2D street canyons: A scaled outdoor experiment. BUILDING AND ENVIRONMENT 2020; 171:106673. [PMID: 32287993 DOI: 10.1016/j.buildenv.2020.106653] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2019] [Revised: 01/04/2020] [Accepted: 01/11/2020] [Indexed: 05/22/2023]
Abstract
Interunit dispersion problems have been studied previously mainly through on-site measurements, wind tunnel tests, and CFD simulations. In this study, a scaled outdoor experiment was conducted to examine the interunit dispersion characteristics in consecutive two-dimensional street canyons. Tracer gas ( C O 2 ) was continuously released to simulate the pollutant dispersion routes between the rooms in street canyons. The wind velocity, wind direction, air temperature, and tracer gas concentrations were monitored simultaneously. Two important parameters, the air exchange rate and reentry ratio, were analyzed to reveal the ventilation performance and interunit dispersion of the rooms in the street canyons. Based on the real-time weather conditions, it was found that the ventilation performance of the source room varied according to the room location. The air exchange rate distribution of the leeward-side room was more stable than that of the windward side. The tracer gas was mainly transported in the vortex direction inside the street canyon, and the highest reentry ratio was observed at the room nearest to the source room along the transportation route. In addition, under real weather conditions, the rooms in the street canyon have a high probability of experiencing a high reentry ratio based on the maximum reentry ratio of each room. This study provides authentic airflow and pollutant dispersion information in the street canyons in an urban environment. The dataset of this experiment can be used to validate further numerical simulations.
Collapse
Affiliation(s)
- Yuwei Dai
- Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Cheuk Ming Mak
- Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Yong Zhang
- School of Atmospheric Sciences, Guangdong Province Key Laboratory for Climate Change and Natural Disaster Studies, Sun Yat-sen University, Guangzhou, 510275, PR China
| | - Dongjin Cui
- School of Architecture & Urban Planning, Shenzhen University, Shenzhen, 518060, PR China
| | - Jian Hang
- School of Atmospheric Sciences, Guangdong Province Key Laboratory for Climate Change and Natural Disaster Studies, Sun Yat-sen University, Guangzhou, 510275, PR China
- Southern Marine Science and Engineering, Guangdong Laboratory (Zhuhai), Zhuhai, PR China
| |
Collapse
|
10
|
Dai Y, Mak CM, Zhang Y, Cui D, Hang J. Investigation of interunit dispersion in 2D street canyons: A scaled outdoor experiment. BUILDING AND ENVIRONMENT 2020; 171:106673. [PMID: 32287993 PMCID: PMC7116958 DOI: 10.1016/j.buildenv.2020.106673] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2019] [Revised: 01/04/2020] [Accepted: 01/11/2020] [Indexed: 05/13/2023]
Abstract
Interunit dispersion problems have been studied previously mainly through on-site measurements, wind tunnel tests, and CFD simulations. In this study, a scaled outdoor experiment was conducted to examine the interunit dispersion characteristics in consecutive two-dimensional street canyons. Tracer gas ( C O 2 ) was continuously released to simulate the pollutant dispersion routes between the rooms in street canyons. The wind velocity, wind direction, air temperature, and tracer gas concentrations were monitored simultaneously. Two important parameters, the air exchange rate and reentry ratio, were analyzed to reveal the ventilation performance and interunit dispersion of the rooms in the street canyons. Based on the real-time weather conditions, it was found that the ventilation performance of the source room varied according to the room location. The air exchange rate distribution of the leeward-side room was more stable than that of the windward side. The tracer gas was mainly transported in the vortex direction inside the street canyon, and the highest reentry ratio was observed at the room nearest to the source room along the transportation route. In addition, under real weather conditions, the rooms in the street canyon have a high probability of experiencing a high reentry ratio based on the maximum reentry ratio of each room. This study provides authentic airflow and pollutant dispersion information in the street canyons in an urban environment. The dataset of this experiment can be used to validate further numerical simulations.
Collapse
Affiliation(s)
- Yuwei Dai
- Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Cheuk Ming Mak
- Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, PR China
- Corresponding author.
| | - Yong Zhang
- School of Atmospheric Sciences, Guangdong Province Key Laboratory for Climate Change and Natural Disaster Studies, Sun Yat-sen University, Guangzhou, 510275, PR China
| | - Dongjin Cui
- School of Architecture & Urban Planning, Shenzhen University, Shenzhen, 518060, PR China
| | - Jian Hang
- School of Atmospheric Sciences, Guangdong Province Key Laboratory for Climate Change and Natural Disaster Studies, Sun Yat-sen University, Guangzhou, 510275, PR China
- Southern Marine Science and Engineering, Guangdong Laboratory (Zhuhai), Zhuhai, PR China
| |
Collapse
|