1
|
Kim JH, Yang YJ, Ahn JS, Shin SY, Lee JH, Choi YS. Research of Optical Properties and Biocompatibility in Different Zones of Multilayered Translucent Zirconia on Hydrothermal Aging. MATERIALS (BASEL, SWITZERLAND) 2024; 17:5189. [PMID: 39517464 PMCID: PMC11547145 DOI: 10.3390/ma17215189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/25/2024] [Revised: 10/11/2024] [Accepted: 10/21/2024] [Indexed: 11/16/2024]
Abstract
OBJECTIVE We assessed the changes in optical properties and biocompatibility of transition zones in multilayered translucent monolithic zirconia exposed to prolonged hydrothermal aging and compared the results to those with different yttrium oxide contents. MATERIALS AND METHODS Four types of zirconia blocks from IPS e.max ZirCAD were used: 3Y-TZP e.max ZirCAD LT (ZL), 4Y-TZP e.max ZirCAD MT (ZM), 5Y-TZP e.max ZirCAD MT Multi (ZT), and 3Y/5Y-TZP e.max ZirCAD Prime (ZP). A total of 120 specimens (15.0 mm diameter and 1.5 mm height) were fabricated and divided into three groups (n = 10). The aging process for the specimens was conducted in an autoclave set to 134 °C and 0.2 MPa, with durations of 0 h (control), 5 h (first aged), and 10 h (second aged). The optical properties and biocompatibility were analyzed, followed by a statistical analysis of the data (α = 0.05). RESULTS Before and after aging, ZL and ZP exhibited the lowest color changes. ZT exhibited the highest average transmittance and translucency parameter values, while ZL had the lowest. The water contact angle test showed the highest value in ZM and lowest in ZL across all the aging stages. ZL, ZM, and ZP showed a considerable decrease in the water contact angle; however, ZT did not. A cell counting kit-8 assay showed ZL had the highest value, while ZM had the lowest. A filamentous actin test exhibited the highest value in ZL and lowest in ZM. In the vinculin analysis, ZL and ZT exhibited the lowest values, whereas ZM and ZP had the highest. CONCLUSION 3Y/5Y-TZP exhibited a balanced performance across critical parameters, such as color stability, translucency, and biocompatibility, aligning with 3Y-TZP. While 5Y-TZP demonstrated superior translucency, it confirmed the lowest color stability, whereas 3Y-TZP achieved the highest biocompatibility. These properties provide clinicians with a reliable material option that ensures superior esthetic outcomes and long-term prognosis, ultimately contributing to improved patient satisfaction and clinical longevity.
Collapse
Affiliation(s)
- Ju-Hyun Kim
- Department of Prosthodontics, College of Dentistry, Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea;
| | - Ye-Jin Yang
- Department of Biomaterials Science, College of Dentistry, Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea;
- Institute of Tissue Regeneration Engineering (ITREN), Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea
| | - Jin-Soo Ahn
- Dental Research Insitute and Biomaterials Science, Dentistry, Seoul National University, Seoul 03080, Republic of Korea;
| | - Soo-Yeon Shin
- Department of Prosthodontics, College of Dentistry, Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea;
| | - Jung-Hwan Lee
- Department of Biomaterials Science, College of Dentistry, Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea;
- Institute of Tissue Regeneration Engineering (ITREN), Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea
- Department of Nanobiomedical Science & BK21 PLUS NBM Global Research Center for Regenerative Medicine Research Center, Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea
- Mechanobiology Dental Medicine Research Center, Dankook University, Cheonan 31116, Republic of Korea
- UCL Eastman-Korea Dental Medicine Innovation Centre, Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea
- Cell & Matter Institute, Dankook University, Cheonan 31116, Republic of Korea
- Department of Regenerative Dental Medicine, School of Dentistry, Dankook University, Cheonan 31116, Republic of Korea
| | - Yu-Sung Choi
- Department of Prosthodontics, College of Dentistry, Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea;
- Mechanobiology Dental Medicine Research Center, Dankook University, Cheonan 31116, Republic of Korea
| |
Collapse
|
2
|
Chen H, Li T, Ng JPZ, Almeheni L, Li KY, Burrow MF. Clinical performance of zirconia-based tooth-supported fixed dental prostheses: A systematic review and meta-analysis. J Dent 2024; 151:105382. [PMID: 39369882 DOI: 10.1016/j.jdent.2024.105382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Revised: 09/28/2024] [Accepted: 09/30/2024] [Indexed: 10/08/2024] Open
Abstract
OBJECTIVES This study aimed to investigate the clinical performance of zirconia-based fixed dental prostheses (FDPs) in comparison to metal-ceramic (MC) FDPs. METHODS A comprehensive search on MEDLINE (PubMed), Web of Science (Core Collection), Scopus up to June 2024 was conducted. Studies that compared the success, survival and complication rates between zirconia based FDPs and MC FDPs were eligible for inclusion. RESULTS Thirty-one articles were identified, of which 22 were included for systematic review and 7 RCTs were included for meta-analysis. 10, 9 and 3 studies were classified to mean follow-up ≤ 5 years, 5 years < mean Follow-up ≤ 10 years, mean Follow-up >10 years, respectively. In the pooled analysis, 180 bilaminar zirconia (ZC) FDPs and 206 MC FDPs were included. ZC FDPs were significantly associated with more failures (RR=3.64, p = 0.009) and more Ceramic Chipping (RR=2.92, p < 0.0001) when compared to MC FDPs. Higher risks of Framework Fracture (RR=4.57, p = 0.18), Loss of Retention (RR=4.79, p = 0.17), Secondary Caries (RR=1.25, p = 0.68), Endodontic complications (RR=1.30, p = 0.74) and Marginal Integrity (RR=1.07, p = 0.88) were also found in ZC FDPs when compared to those of MC FDPs, but with no statistical difference. CONCLUSION The current evidence continues to support the preference for traditional MC FDPs over ZC FDPs. Studies indicate that ZC FDPs have higher failure rates and more complications compared to MC FDPs, with ceramic chipping being a significant concern. There is lack of long term (>10 years follow-up) evidence of the clinical performance of ZC FDPs and monolithic zirconia FDPs. CLINICAL SIGNIFICANCE The study suggests that despite the growing popularity of zirconia, evidence shows MC FDPs may still be considered preferable to ZC FDPs.
Collapse
Affiliation(s)
- Hui Chen
- Division of Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR
| | - Tianle Li
- Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR
| | - Joanne Pui Zhee Ng
- Division of Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR
| | - Lolwa Almeheni
- Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR
| | - Kar Yan Li
- Clinical Research Centre, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR
| | - Michael Francis Burrow
- Division of Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR.
| |
Collapse
|
3
|
Fathi A, Natanzian Y, Ghorbani M, Mosharraf R. Evaluation of the Bonding Shear Strength between Enamel and Dentin Feldspathic Porcelain and Two Different Monolithic Zirconia with Low and High Translucency. Int J Dent 2024; 2024:5921637. [PMID: 39148645 PMCID: PMC11326879 DOI: 10.1155/2024/5921637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 05/25/2024] [Accepted: 07/17/2024] [Indexed: 08/17/2024] Open
Abstract
Introduction The utilization of ceramics in the field of dentistry has seen a significant rise owing to their esthetic appeal and excellent functional properties. The use of ceramics in the field of dentistry has witnessed a notable surge, driven by their appealing esthetics and exceptional functional attributes. Zirconia, distinguished by its exceptional mechanical strength, plays a pivotal role in the fabrication of posterior crowns and bridges. Among zirconia variants, monolithic zirconia stands out, where the entire restoration is crafted from zirconia material. In parallel, feldspathic porcelain, chosen for its remarkable resemblance to natural tooth enamel, represents another significant ceramic type. This study aims to evaluate the shear bond strength (SBS) between two types of monolithic zirconia with two types of feldspathic porcelain. Methods and Materials Forty-four monolithic zirconia veneered discs with feldspathic porcelain were subjected to SBS testing. The dimensions of the discs were 7 mm in diameter and 5 mm in height (3 mm of zirconia and 2 mm of porcelain). Subsequently, the specimens were subjected to a universal testing machine at a speed of 0.5 mm/min until failure occurred. The type of failure was examined using scanning electron microscopy. One-way analysis of variance (ANOVA), two-way ANOVA, Fisher's test, and multiple Tukey comparisons were used as statistical analyses. Results The highest SBS was achieved by the high-translucency monolithic zirconia with enamel porcelain group (18.81 ± 3.18 MPa) and the high-translucency monolithic zirconia with dentin porcelain group (17.89 ± 2.75 MPa), followed by the low-translucency monolithic zirconia with dentin porcelain group (15.04 ± 2.24 MPa) and the low-translucency monolithic zirconia with enamel porcelain group (14.33 ± 2.00 MPa), respectively. Additionally, the most common type of failure pattern observed was mixed, followed by adhesive failure. Conclusion The translucency of the porcelain did not significantly affect SBS, while the type of monolithic zirconia used had a significant impact. Furthermore, there was no discernible relationship between the four groups in terms of the distribution of failure patterns.
Collapse
Affiliation(s)
- Amirhossein Fathi
- Department of Prosthodontics Dental Materials Research Center Isfahan University of Medical Sciences, Isfahan, Iran
| | - Yeganeh Natanzian
- Dental Students' Research Committee School of Dentistry Isfahan University of Medical Sciences, Isfahan, Iran
| | - Mahsa Ghorbani
- School of Dentistry Mashhad University of Medical Sciences, Mashhad, Iran
| | - Ramin Mosharraf
- Department of Prosthodontics Dental Materials Research Center Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
4
|
Akhlaghi O, Camposilvan E, Garnier V, Goharibajestani Z, Khabbaz S, Ow-Yang C, Jorand Y, Gremillard L, Chevalier J. Conventional sintering of nano-crystalline Yttria-Stabilized Zirconia enables high-strength, highly translucent and opalescent dental ceramics. Dent Mater 2024; 40:1031-1040. [PMID: 38755041 DOI: 10.1016/j.dental.2024.05.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 04/30/2024] [Accepted: 05/03/2024] [Indexed: 05/18/2024]
Abstract
Development of restorative materials capable of mimicking optical and mechanical performance of natural teeth is a quest in aesthetic density. Yttria-Stabilized Zirconia (YSZ) ceramics represent one of the most popular choices for dental restorations, owing to their biocompatibility, white colour, and the possibility to use CAD-CAM technologies. In particular, YSZ doped with 3 mol. % yttria (3YSZ) is popular because it presents high strength. Nonetheless, the limited light transmission of commercially available high strength 3YSZ does not meet the requirements of highly aesthetic cases. On the other side, YSZ presenting a larger portion of yttria are more translucent but exhibit modest strength. Here, we report on fabrication of dense zirconia nanostructures in bulk form via conventional pressure-less sintering at temperatures down to 1100-1200 °C, achieving highly translucent and strong 3YSZ with significant opalescent behaviour. Both Hall-Petch and inverse Hall-Petch relationship were observed in 3YSZ samples with average grain size in the range of 250 nm and 55 nm, demonstrating the importance of grain size control to enhance both optical and mechanical properties of zirconia ceramics, simultaneously. Maximum biaxial strength of 1980 ± 260 MPa, in-line light transmission of 38% in the visible spectrum and opalescence approaching that of enamel were obtained at optimum grain size of 80 ± 5 nm. The notable optical properties are linked to the miniaturization of the residual pores and refinement of grain size towards the nanoscale while the superior mechanical strength is justified by the activation of different energy dissipation processes at nano and macroscale.
Collapse
Affiliation(s)
- Omid Akhlaghi
- INSA Lyon, Universite Claude Bernard Lyon 1, CNRS, MATEIS, UMR5510, 69621 Villeurbanne, France
| | | | - Vincent Garnier
- INSA Lyon, Universite Claude Bernard Lyon 1, CNRS, MATEIS, UMR5510, 69621 Villeurbanne, France.
| | | | - Sirous Khabbaz
- Materials Science & Nano-Engineering Program, Sabanci University, Tuzla, Istanbul 34956, Turkey
| | - Cleva Ow-Yang
- Materials Science & Nano-Engineering Program, Sabanci University, Tuzla, Istanbul 34956, Turkey; Nanotechnology Research and Application Center (SUNUM), Sabanci University, Tuzla, Istanbul 34956, Turkey
| | - Yves Jorand
- INSA Lyon, Universite Claude Bernard Lyon 1, CNRS, MATEIS, UMR5510, 69621 Villeurbanne, France
| | - Laurent Gremillard
- INSA Lyon, Universite Claude Bernard Lyon 1, CNRS, MATEIS, UMR5510, 69621 Villeurbanne, France
| | - Jérôme Chevalier
- INSA Lyon, Universite Claude Bernard Lyon 1, CNRS, MATEIS, UMR5510, 69621 Villeurbanne, France
| |
Collapse
|
5
|
Sayed ME, Lunkad H, Mohana EJ, Mesawa SA, Dowairi FI, Alharbi EAA, Hakami HA, Jokhadar HF, Alqahtani NM, Alshehri AH, Alsubaiy EF, Alqahtani SM, Mohsen NM, Al Wadei MH, Mattoo K. The Impact of Repeated Steam Sterilization Cycles on the Efficacy of Chairside Adjustment Kits for Polishing Monolithic Multi-Layered Zirconia Dental Restoration Material. Med Sci Monit 2024; 30:e944502. [PMID: 38857196 PMCID: PMC11177719 DOI: 10.12659/msm.944502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Accepted: 04/16/2024] [Indexed: 06/12/2024] Open
Abstract
BACKGROUND Before insertion, chairside adjustment kits are heat sterilized for positioning and polishing dental restorations. This study aimed to evaluate the effects of 2 steam sterilization cycles on the efficacy of polishing highly translucent monolithic zirconia (HTMLZ) dental restoration material. MATERIAL AND METHODS 100 HTMLZ disc-shaped specimens were adjusted (grinding, finishing, polishing) with EVE Diacera kit. Two steam sterilization techniques [standard (Gp S), immediate/flash (Gp (F)] of CAK were further subgrouped based on number of sterilization cycles [cycle 1 (control), cycle 5, 10, 15, and 20 (experimental)] (n=10 each). Each subgroup accordingly was evaluated for average surface roughness (Ra) and root mean square roughness (Rq) using a profilometer. Mean and standard deviation of 5 subgroups were statistically analyzed using one-way ANOVA/post hoc Tukey's test. Scanning electron microscopy complemented Ra, Rq measurements. Statistical differences of P≤0.05 were considered significant. RESULTS HTMLZ specimens in both groups showed increased (Ra/Rq) values after repeated sterilization of EVE Diacera kit, with Gp F showing lesser increase than Gp S (20 cycles). Gp F at 10 cycles and Gp S at 15 cycles showed clinically unacceptable roughness threshold (0.25 μm). Differences between subgroups for Ra and Rq values were significant (P≤0.05) with less differences within groups observed in early cycles (1, 10). Results validate the manufacturer's recommendations of using flash sterilization/10 cycles for EVE Diacera kit. CONCLUSIONS Repeated sterilization reduces efficacy of chairside adjustment kit to produce smooth surfaces on HTMLZ. This study recommends flash sterilization to a maximum of 10 times to get the clinically acceptable results of Ra and Rq.
Collapse
Affiliation(s)
- Mohammed E. Sayed
- Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Honey Lunkad
- Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Enas Jaber Mohana
- Intern Clinic, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Sara Ahmad Mesawa
- Intern Clinic, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | | | | | - Hayat Ali Hakami
- Undergraduate Student, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Hossam F. Jokhadar
- Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Nasser M. Alqahtani
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Abdullah Hasan Alshehri
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Ebrahim Fihaid Alsubaiy
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Saeed M. Alqahtani
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | | | - Mohammed H.D. Al Wadei
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Khurshid Mattoo
- Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| |
Collapse
|
6
|
Dimitriadis K, Tulyaganov DU, Agathopoulos S. Evaluation of bond strength between zirconia milled ceramic material and veneered dental porcelain. Eur J Oral Sci 2024; 132:e12989. [PMID: 38679835 DOI: 10.1111/eos.12989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 04/05/2024] [Indexed: 05/01/2024]
Abstract
This study aimed at examining the bond strength between zirconia and ceramic veneer, following the ISO 9693 guidelines. A total of fifty specimens of zirconia/ceramic-veneer system were produced using two commercial zirconias (VITA YZ-HTWhite and Zolid HT+ White, referred to as Group A and Group B, respectively) and a ceramic-veneering material (Zirkonia 750). The microstructure (via x-ray diffraction analysis, XRD and Secondary Electron mode, SEM) and the mechanical properties (via 3-point bending tests) of the two groups were assessed. Then, experiments were conducted according to the ISO 9693 and conventional protocols applied for producing zirconia/ceramic-veneer restorations. Bond strength values, measured by 3-point bending tests, were 34.42 ± 7.60 MPa for Group A and 31.92 ± 6.95 MPa for Group B. SEM observations of the cohesively fractured surfaces (on the porcelain side) and the examination for normality using the Shapiro-Wilk test suggested the use of Weibull statistical analysis. Median strength (σ50%) for Group A and Group B was 34.76 and 32.22 MPa, while the characteristic strength (σ63.2%) was 35.78 and 33.14 MPa, respectively. The Weibull modulus disparity between groups (12.69 and 13.07) was not significant. Bond strength exceeded the ISO 9693 minimum of 20 MPa, suggesting satisfactory strength for clinical use.
Collapse
Affiliation(s)
- Konstantinos Dimitriadis
- Division of Dental Technology, Department of Biomedical Sciences, University of West Attica, Athens, Greece
| | - Dilshat U Tulyaganov
- Department of Natural-Mathematical Sciences, Turin Polytechnic University in Tashkent, Tashkent, Uzbekistan
| | - Simeon Agathopoulos
- Department of Materials Science and Engineering, School of Engineering, University of Ioannina, Ioannina, Greece
| |
Collapse
|
7
|
Cho SM, Young Kim RJ, Park JM, Chung HM, Kim DY. Trueness, physical properties, and surface characteristics of additive-manufactured zirconia crown. J Mech Behav Biomed Mater 2024; 154:106536. [PMID: 38579394 DOI: 10.1016/j.jmbbm.2024.106536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 03/29/2024] [Accepted: 03/31/2024] [Indexed: 04/07/2024]
Abstract
OBJECTIVE This study aimed to conduct a comparison of trueness and physical and surface properties among five distinct types of additive manufactured (AM) zirconia crowns and zirconia crowns produced using the subtractive manufacturing (SM). MATERIAL AND METHODS Zirconia crowns were fabricated using five distinct techniques, each varying in the method of slurry transfer and photocuring source. Each experimental group utilized either one of the four digital light processing (DLP)-based techniques (DLP spreading, DLP spreading gradation, DLP vat and DLP circular spreading) or the stereolithography (SLA)-based technique (SLA spreading). The control (CON) group employed SM. To assess accuracy, trueness was measured between the scan and reference data. To analyze the physical properties, voids were examined using high-energy spiral micro-computed tomography scans, and the crystal structure analysis was performed using X-ray diffraction (XRD). Surface roughness was assessed through laser scanning microscopy. RESULTS Differences in the trueness of internal surfaces of crowns were found among the groups (P < 0.05). Trueness varied across the measurement surfaces (occlusal, lateral, and marginal) in all the groups except for the DLP spreading gradation group (P < 0.05). Voids were observed in all AM groups. All groups showed similar XRD patterns. All AM groups showed significantly greater surface roughness compared to the CON group (P < 0.001). CONCLUSION The AM zirconia crowns showed bubbles and a rougher surface compared to the SM crowns. All groups exhibited typical zirconia traits and trueness levels within clinically acceptable limits, suggesting that current zirconia AM techniques could be suitable for dental applications.
Collapse
Affiliation(s)
- Su-Min Cho
- Dental Research Institute, Seoul National University School of Dentistry, 101, Daehak-ro, Jongno-gu, Seoul, Republic of Korea.
| | - Ryan Jin Young Kim
- Dental Research Institute, Seoul National University School of Dentistry, 101, Daehak-ro, Jongno-gu, Seoul, Republic of Korea.
| | - Ji-Man Park
- Department of Prosthodontics & Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea.
| | - Hye-Min Chung
- Department and Research Institute of Dental Biomaterials and Bioengineering, Yonsei University College of Dentistry, 50-1, Yonsei-ro, Seodaemun-gu, Seoul, Republic of Korea.
| | - Deok-Yeong Kim
- Dental Research Institute, Seoul National University School of Dentistry, 101, Daehak-ro, Jongno-gu, Seoul, Republic of Korea.
| |
Collapse
|
8
|
Cesar PF, Miranda RBDP, Santos KF, Scherrer SS, Zhang Y. Recent advances in dental zirconia: 15 years of material and processing evolution. Dent Mater 2024; 40:824-836. [PMID: 38521694 PMCID: PMC11098698 DOI: 10.1016/j.dental.2024.02.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Revised: 02/26/2024] [Accepted: 02/27/2024] [Indexed: 03/25/2024]
Abstract
OBJECTIVES The objective was to discuss the research on zirconia published in the past 15 years to help the dental materials community understand the key properties of the types of zirconia and their clinical applications. METHODS A literature search was performed in May/2023 using Web of Science Core Collection with the term "dental zirconia". The search returned 5102 articles, which were categorized into 31 groups according to the research topic. RESULTS The current approach to improving the translucency of zirconia is to decrease the alumina content while increasing the yttria content. The resulting materials (4Y-, 5Y-, and above 5 mol% PSZs) may contain more than 50% of cubic phase, with a decrease in mechanical properties. The market trend for zirconia is the production of CAD/CAM disks containing more fracture resistant 3Y-TZP at the bottom layers and more translucent 5Y-PSZ at the top. Although flaws located between layers in multilayered blocks might represent a problem, newer generations of zirconia layered blocks appear to have solved this problem with novel powder compaction technology. Significant advancements in zirconia processing technologies have been made, but there is still plenty of room for improvement, especially in the fields of high-speed sintering and additive manufacturing. SIGNIFICANCE The wide range of zirconia materials currently available in the market may cause confusion in materials selection. It is therefore imperative for dental clinicians and laboratory technicians to get the needed knowledge on zirconia material science, to follow manufacturers' instructions, and to optimize the design of the prosthetic restoration with a good understanding where to reinforce the structure with a tough and strong zirconia.
Collapse
Affiliation(s)
- Paulo Francisco Cesar
- Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo, São Paulo, Brazil.
| | | | - Karina Felix Santos
- Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Susanne S Scherrer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, USA
| |
Collapse
|
9
|
Alshahrani AM, Lim CH, Wolff MS, Janal MN, Zhang Y. Current speed sintering and high-speed sintering protocols compromise the translucency but not strength of yttria-stabilized zirconia. Dent Mater 2024; 40:664-673. [PMID: 38378371 PMCID: PMC11015968 DOI: 10.1016/j.dental.2024.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 01/05/2024] [Accepted: 02/12/2024] [Indexed: 02/22/2024]
Abstract
OBJECTIVES To investigate the impacts of speed and high-speed sintering on the densification, microstructure, phase composition, translucency, and flexural strength of yttria-stabilized zirconia (YSZ). METHODS A total of 162 disc-shaped specimens (n = 18) were cold-isostatically pressed from 3YSZ (Zpex), 4YSZ (Zpex 4), and 5YSZ (Zpex Smile) powders (Tosoh Corporation) and sintered according to the following protocols: conventional (control, ∼12 h), speed (∼28 min for 3YSZ; ∼60 min for 4YSZ and 5YSZ), and high-speed (∼18 min) sintering. Dimensions of zirconia specimens after sintering and polishing (1-μm diamond grit finish) were Ø13.75 × 1 mm. Density, microstructure, phase content, translucency parameter, and biaxial flexural strength were evaluated using Archimedes', SEM, XRD, spectrophotometric, and piston-on-3-ball methods, respectively. Data were analyzed with either one-way ANOVA and Tukey's test or Kruskal-Wallis with Dunn's test (α = 0.05). RESULTS For all YSZ compositions, conventional sintering yielded the highest density followed by speed then high-speed sintering. All sintering protocols resulted in similar strength values; however, speed and high-speed sintering protocols afforded significantly lower translucency relative to conventional sintering. XRD analysis revealed similar spectra for YSZs sintered by various protocols. The speed sintered specimens had the smallest grain size whereas the high-speed sintered 5YSZ possessed the largest grain size among all groups. SEM examination of all YSZ compositions revealed that the average pore size was an order of magnitude smaller than the average grain size. SIGNIFICANCE Speed and high-speed sintering of YSZs yield similar strength but diminished density and translucency relative to their conventionally sintered counterparts.
Collapse
Affiliation(s)
- Abdulaziz M Alshahrani
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Chek Hai Lim
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Mark S Wolff
- Morton Amsterdam Dean, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Malvin N Janal
- Department of Epidemiology & Health Promotion, New York University College of Dentistry, New York, NY 10010, USA
| | - Yu Zhang
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
| |
Collapse
|
10
|
Sudharson NA, Gandhi N, Talwar H, Kurian N, Joseph M. A comparative analysis of mechanical and optical behavioral patterns of translucent zirconia ceramics. J Indian Prosthodont Soc 2024; 24:88-94. [PMID: 38263563 PMCID: PMC10896311 DOI: 10.4103/jips.jips_341_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 11/28/2023] [Accepted: 12/23/2023] [Indexed: 01/25/2024] Open
Abstract
AIM This research aimed to assess and compare the translucency and mechanical properties of partially stabilized zirconia in contrast to lithium disilicate, particularly within the context of translucent zirconia. SETTINGS AND DESIGN The experimental design entails examining fifty samples, with ten drawn from each of the five distinct categories of ceramic materials, as part of this in vitro study. Translucency is measured using the Konica Minolta CM-3600D spectrophotometer, assessing Delta E through Lab values against white and black backgrounds. Flexural strength is analyzed via a 3-point bend test on a universal testing machine, with a controlled crosshead speed set at 1 mm/min. MATERIALS AND METHODS The study included the five categories of ceramic materials, each consisting of ten samples: High-strength zirconia (Katana HT), translucent zirconia (e.max Zircad MT and Cercon ht ML), and lithium disilicate (Press MT and LT). The Konica Minolta CM-3600D spectrophotometer is utilized to measure the translucency parameter. This involves determining the color difference (Delta E) by comparing the L*a*b values against both white and black backgrounds. The flexural strength (FS) of zirconia and lithium disilicate materials was analyzed through a 3-point bend test, aiming to compare their respective strengths. The testing procedure was carried out on a universal testing machine with a controlled crosshead speed set at 1 mm/min. The FS was calculated using the formula σ = FL/πR3 for circular disks, where σ represents the FS, F is the fracture load, L is the span length in millimeters, and R is the radius of the disk. STATISTICAL ANALYSIS USED The Student's t-test was employed for statistical analysis. RESULTS The mean translucency parameter for e.max Press MT (6.33 ± 1.05) was significantly greater than all the specimens investigated. The Cercon ht ML exhibited a slightly higher translucency (2.18 ± 0.52) compared to e.max Zircad MT (1.49 ± 0.69), with a statistically significant difference (P = 0.022). Conversely, the FS of e.max Zircad MT (26.97 ± 2.06) was significantly greater (P < 0.001) than that of Cercon ht ML (23.25 ± 2.36). Notably, the Katana HT material demonstrated the highest load strength (32.92 ± 3.10), a statistically significant difference compared to its counterparts (P < 0.001). CONCLUSIONS Among the materials tested, lithium disilicate ceramics exhibited the highest translucency, with its MT variant demonstrating the lowest strength. Katana HT displayed significantly greater biaxial FS compared to translucent zirconia, surpassing even lithium disilicate. Translucent zirconia proved to be notably more translucent than high-strength zirconia. Within the category of translucent zirconia, e.max Zircad MT exhibited substantially higher FS than Cercon.
Collapse
Affiliation(s)
| | - Nitasha Gandhi
- Department of Prosthodontics, Christian Dental College, Ludhiana, Punjab, India
| | - Harit Talwar
- Department of Prosthodontics, Christian Dental College, Ludhiana, Punjab, India
| | - Nirmal Kurian
- Department of Prosthodontics, Christian Dental College, Ludhiana, Punjab, India
| | - Meril Joseph
- Department of Prosthodontics, Christian Dental College, Ludhiana, Punjab, India
| |
Collapse
|
11
|
Sulaiman TA, Suliman AA, Abdulmajeed AA, Zhang Y. Zirconia restoration types, properties, tooth preparation design, and bonding. A narrative review. J ESTHET RESTOR DENT 2024; 36:78-84. [PMID: 37840220 PMCID: PMC10842315 DOI: 10.1111/jerd.13151] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 10/01/2023] [Accepted: 10/03/2023] [Indexed: 10/17/2023]
Abstract
OBJECTIVE The purpose of this review was to provide dental professionals with information regarding the various types of zirconia restorations, their mechanical and optical properties, tooth preparation design, and bonding protocol in an effort to enhance the longevity and durability of zirconia restorations. OVERVIEW The yttria content of zirconia ceramics determines their classification. The mechanical and optical properties of each type are discussed, with an emphasis on the effect of yttria concentration on the properties of zirconia. The processing and sintering methods are also discussed as they have a direct impact on the properties of zirconia. The design of tooth preparation, specifically occlusal reduction, varies depending on the type of zirconia used in each case. Finally, a protocol for zirconia restoration bonding is described to ensure optimal bonding to the tooth structure. CONCLUSION Not all zirconia restorations are the same. The selection of zirconia type based on yttria concentration, processing and sintering methods, tooth preparation design, and adherence to the bonding protocol are all critical to the success and longevity of zirconia restorations. CLINICAL SIGNIFICANCE Zirconia restorations are the most commonly used indirect restorative material. The selection of the most appropriate zirconia type based on its yttria content, which determines its strength and translucency, is critical to the success and the longevity of the restoration. Tooth preparation design also influences the strength and translucency of the zirconia. Air-borne particle abrasion, followed by a ceramic primer and resin cement, can ensure a durable bond to the tooth structure.
Collapse
Affiliation(s)
- Taiseer A Sulaiman
- Division of Comprehensive Oral Health, University of North Carolina, Adams School of Dentistry, Chapel Hill, North Carolina, USA
| | - Abdulhaq A Suliman
- Department of Clinical Sciences, College of Dentistry, Ajman University, Ajman, UAE
| | - Aous A Abdulmajeed
- Department of General Practice, School of Dentistry, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
12
|
Yigit BS, Al-Akkad M, Mounajjed R. Zirconia Ceramics. ACTA MEDICA (HRADEC KRALOVE) 2024; 67:39-45. [PMID: 39434669 DOI: 10.14712/18059694.2024.18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2024]
Abstract
Zirconia ceramics have become popular among other dental ceramics thanks to their biological, mechanical, optical, and aesthetic properties. CAD/CAM (computer-aided design/ computer-aided manufacturing) technology improvement has played a vital role in the increased popularity of zirconia ceramics; easy computer manipulation significantly expanded the possibility of using different types of restorations. Zirconia ceramics have a broad spectrum of indications in prosthetic dentistry, from simple restorations to complex structures supported by dental implants. A good orientation in the classification, features, and manipulation of zirconia ceramics is the main key to success.
Collapse
Affiliation(s)
- Bedirhan Savas Yigit
- Institute of Dentistry and Oral Sciences, Palacky University Olomouc, Olomouc, Czech Republic
| | - Marwan Al-Akkad
- Institute of Dentistry and Oral Sciences, Palacky University Olomouc, Olomouc, Czech Republic
| | - Radek Mounajjed
- Institute of Dentistry and Oral Sciences, Palacky University Olomouc, Olomouc, Czech Republic.
- Private Clinician, DCM Clinic, Hradec Králové, Czech Republic.
| |
Collapse
|
13
|
Unnadkat A, Kirby L, Kulanthaivel S, Rysavy O, Tsujimoto A, Song X, Teixeira EC. The Effect of Sintering on Zirconia Manufactured via Suspension-Enclosing Projection Stereolithography for Dental Applications: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2023; 17:14. [PMID: 38203868 PMCID: PMC10779720 DOI: 10.3390/ma17010014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 12/11/2023] [Accepted: 12/12/2023] [Indexed: 01/12/2024]
Abstract
BACKGROUND Zirconia is a widely used material in the dental industry due to its excellent mechanical and aesthetic properties. Recently, a new 3D printing process called suspension-enclosing projection stereolithography (SEPS) was introduced to fabricate zirconia dental restorations. However, the effect of the sintering time and temperature on the properties of zirconia produced via SEPS has not been fully investigated. METHODS Zirconia slurries were prepared with varying percentages of zirconia powders and 3D printing resins, and 5Y-TZP (5 mol% yttria-stabilized zirconia) (n = 40) and 3Y-TZP (3 mol% yttria-stabilized zirconia) (n = 40) bar specimens were fabricated via SEPS manufacturing. The specimens were sintered at different temperatures and dwell times, and their flexural strength, density, and phase composition were measured. The viscosity of the slurries was also measured. Statistical analysis was performed using Welch's ANOVA and Kruskal-Wallis tests to evaluate the impact of the sintering conditions. RESULTS Significant differences in flexural strength (p < 0.01) were observed between the 5Y-TZP samples, with those sintered at 1530 °C for 120 min showing an average strength of 268.34 ± 44.66 MPa, compared to 174.16 ± 42.29 MPa for those sintered at 1450 °C for 120 min. In terms of density, significant differences (p < 0.01) were noted for the 3Y-TZP specimens, with an average density of 6.66 ± 0.49 g/cm3 for samples sintered at 1530 °C for 120 min, versus 5.75 ± 0.55 g/cm3 for those sintered at 1530 °C for 10 min. X-ray diffraction confirmed the presence of a predominantly tetragonal phase in both materials. CONCLUSIONS Zirconia printed via SEPS manufacturing can be sintered at a higher temperature with shorter dwell times, thereby producing high density samples. Different sintering conditions can be used to fully sinter 3D-printed zirconia for potential dental applications.
Collapse
Affiliation(s)
- Amit Unnadkat
- Department of General Dentistry, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN 38163, USA;
| | - Levi Kirby
- Department of Industrial and Systems Engineering, The University of Iowa College of Engineering, Iowa City, IA 52242, USA
| | - Senthilguru Kulanthaivel
- Department of Operative Dentistry, The University of Iowa College of Dentistry and Dental Clinics, Iowa City, IA 52242, USA; (S.K.); (A.T.)
| | - Oscar Rysavy
- Division of Biostatistics and Computational Biology, The University of Iowa College of Dentistry and Dental Clinics, Iowa City, IA 52242, USA
- Department of Biostatistics, The University of Iowa College of Public Health, Iowa City, IA 52242, USA
| | - Akimasa Tsujimoto
- Department of Operative Dentistry, The University of Iowa College of Dentistry and Dental Clinics, Iowa City, IA 52242, USA; (S.K.); (A.T.)
- Department of Operative Dentistry, Aichi Gakuin University School of Dentistry, Chikusa-ku, Nagoya 464-8651, Aichi, Japan
- Department of General Dentistry, Creighton University School of Dentistry, Omaha, NE 68102, USA
| | - Xuan Song
- Department of Industrial and Systems Engineering, The University of Iowa College of Engineering, Iowa City, IA 52242, USA
| | - Erica C. Teixeira
- Department of Operative Dentistry, The University of Iowa College of Dentistry and Dental Clinics, Iowa City, IA 52242, USA; (S.K.); (A.T.)
| |
Collapse
|
14
|
Pereira RM, Moreira Bastos Campos T, Augusto Bonfante E, Patrocínio Thim G. A comparative study of mechanical properties of yttria stabilized zirconia monolithic and bilayer configuration for dental application. J Mech Behav Biomed Mater 2023; 148:106160. [PMID: 37832171 DOI: 10.1016/j.jmbbm.2023.106160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Revised: 09/28/2023] [Accepted: 09/30/2023] [Indexed: 10/15/2023]
Abstract
Zirconia multilayer presents promising prospects, but there is scarce information about its microstructural and mechanical characterization. Therefore, this study sought to produce them in-house and to perform their characterization by comprising four groups of specimens to assess the biaxial flexural strength, microhardness, fracture toughness, phase characterization and quantification, fractography, and microstructural features. Weibull analysis was performed to determine the Weibull modulus and characteristic strength. The results showed that bilayers 3YSZ and 5YSZ presented intermediate mechanical properties when compared to 3YSZ and 5YSZ monolithic controls (680 MPa, 464 MPa, 885 MPa, 594 MPa, respectively). Fractographic analysis revealed that the failure origin was not at the interface in the bilayer groups, but residual stress was present between the layers. Hardness and fracture toughness were not affected by the interface.
Collapse
Affiliation(s)
- Raíssa Monteiro Pereira
- Laboratory of Plasma and Process, Technological Institute of Aeronautics, Praça Marechal Eduardo Gomes, 50, Vila das Acácias, São José dos Campos, SP, 12228-900, Brazil.
| | - Tiago Moreira Bastos Campos
- Laboratory of Plasma and Process, Technological Institute of Aeronautics, Praça Marechal Eduardo Gomes, 50, Vila das Acácias, São José dos Campos, SP, 12228-900, Brazil
| | - Estevam Augusto Bonfante
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry - University of São Paulo, Bauru, SP, Brazil
| | - Gilmar Patrocínio Thim
- Laboratory of Plasma and Process, Technological Institute of Aeronautics, Praça Marechal Eduardo Gomes, 50, Vila das Acácias, São José dos Campos, SP, 12228-900, Brazil
| |
Collapse
|
15
|
Park C, Giap HV, Kwon JS, Kim KH, Choi SH, Lee JS, Lee KJ. Dimensional accuracy, mechanical property, and optical stability of zirconia orthodontic bracket according to yttria proportions. Sci Rep 2023; 13:20418. [PMID: 37990080 PMCID: PMC10663543 DOI: 10.1038/s41598-023-47827-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Accepted: 11/18/2023] [Indexed: 11/23/2023] Open
Abstract
This in vitro study evaluated comprehensively the performances of zirconia brackets with varying yttria proportions in manufacturing advanced orthodontic brackets. Three experimental groups of zirconia brackets were fabricated using yttria-stabilized zirconia (YSZ) materials with different yttria proportions-3 mol% yttria (3Y-YSZ), 4 mol% yttria (4Y-YSZ), and 5 mol% yttria (5Y-YSZ) (Tosoh Ceramic, Japan). A polycrystalline alumina ceramic bracket (3M™ Clarity™ Advanced, MBT 0.022-in. slot) was employed as the control group. Morphological properties, including slot surface structure and dimensions, were examined using scanning electron microscopy and surface profiler analysis. Manufacturing accuracy was assessed with root mean square calculations of trueness and precision. Mechanical properties were tested, encompassing static and kinetic frictional resistance (FR) and fracture strength. Optical stability was evaluated through 20,000 cycles of thermocycling and a 7-day immersion in various coloring agents. Within the limitations of this study, zirconia brackets containing 3 to 5 mol% YSZ presented enhanced reliability in terms of dimensional accuracy and demonstrated favorable optical stability. Notably, owing to its advantageous mechanical properties, the 3Y-YSZ variant showed remarkable potential as an advanced material for fabricating orthodontic brackets.
Collapse
Affiliation(s)
- Changbum Park
- Department of Orthodontics, Institute of Craniofacial Deformity, Yonsei University College of Dentistry, No. 723, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Hai-Van Giap
- Department of Orthodontics, Institute of Craniofacial Deformity, Yonsei University College of Dentistry, No. 723, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Jae-Sung Kwon
- Department and Research Institute for Dental Biomaterials and Bioengineering, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kyung-Ho Kim
- Department of Orthodontics, Institute of Craniofacial Deformity, Yonsei University College of Dentistry, No. 723, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Sung-Hwan Choi
- Department of Orthodontics, Institute of Craniofacial Deformity, Yonsei University College of Dentistry, No. 723, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Joon Sang Lee
- Department of Mechanical Engineering, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kee-Joon Lee
- Department of Orthodontics, Institute of Craniofacial Deformity, Yonsei University College of Dentistry, No. 723, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
16
|
Mory N, Cascos R, Celemín-Viñuela A, Gómez-Polo C, Agustín-Panadero R, Gómez-Polo M. Comparison of the Surface Roughness of CAD/CAM Metal-Free Materials Used for Complete-Arch Implant-Supported Prostheses: An In Vitro Study. Biomedicines 2023; 11:3036. [PMID: 38002036 PMCID: PMC10669478 DOI: 10.3390/biomedicines11113036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 11/02/2023] [Accepted: 11/06/2023] [Indexed: 11/26/2023] Open
Abstract
The roughness of the intra-oral surfaces significantly influences the initial adhesion and the retention of microorganisms. The aim of this study was to analyze the surface texture of four different CAD-CAM materials (two high-performance polymers and two fifth-generation zirconia) used for complete-arch implant-supported prostheses (CAISPs), and to investigate the effect of artificial aging on their roughness. A total of 40 milled prostheses were divided into 4 groups (n = 10) according to their framework material, bio.HPP (B), bio.HPP Plus (BP), zirconia Luxor Z Frame (ZF), and Luxor Z True Nature (ZM). The areal surface roughness "Sa" and the maximum height "Sz" of each specimen was measured on the same site after laboratory fabrication (lab as-received specimen) and after thermocycling (5-55 °C, 10,000 cycles) by using a noncontact optical profilometer. Data were analyzed using SPSS version 28.0.1. One-way ANOVA with multiple comparison tests (p = 0.05) and repeated measures ANOVA were used. After thermocycling, all materials maintained "Sa" values at the laboratory as-received specimen level (p = 0.24). "Sz" increased only for the zirconia groups (p = 0.01). B-BP exhibited results equal/slightly better than ZM-ZF. This study provides more realistic surface texture values of new metal-free materials used in real anatomical CAISPs after the manufacturing and aging processes and establishes a detailed and reproducible measurement workflow.
Collapse
Affiliation(s)
- Nataly Mory
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (N.M.); (A.C.-V.); (M.G.-P.)
| | - Rocío Cascos
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (N.M.); (A.C.-V.); (M.G.-P.)
- Department of Nursing and Estomatology, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain
- Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, 28670 Madrid, Spain
| | - Alicia Celemín-Viñuela
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (N.M.); (A.C.-V.); (M.G.-P.)
| | - Cristina Gómez-Polo
- Department of Surgery, Faculty of Medicine, University of Salamanca, 37007 Salamanca, Spain;
| | - Rubén Agustín-Panadero
- Prosthodontic and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, 46010 Valencia, Spain;
| | - Miguel Gómez-Polo
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (N.M.); (A.C.-V.); (M.G.-P.)
| |
Collapse
|
17
|
Choo SS, Ko KH, Huh YH, Park CJ, Cho LR. Fatigue resistance of anterior monolithic crowns produced from CAD-CAM materials: An in vitro study. J Prosthet Dent 2023; 130:620-628. [PMID: 34980473 DOI: 10.1016/j.prosdent.2021.09.034] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Revised: 09/29/2021] [Accepted: 09/29/2021] [Indexed: 10/19/2022]
Abstract
STATEMENT OF PROBLEM Lithium disilicate and 5 mol% yttria partially stabilized zirconia (5Y-PSZ) are commonly used for anterior restorations. However, studies comparing the durability of 5Y-PSZ and lithium disilicates are sparse. PURPOSE The purpose of this in vitro study was to investigate the fracture load of anterior monolithic crowns made of 2 lithium disilicates and a 5Y-PSZ under dynamic loading. MATERIAL AND METHODS Titanium abutments of the maxillary incisors were prepared (N=48, 8 for each group). Monolithic anterior crowns were made from the lithium disilicates (e.max CAD, Rosetta SM) and 5Y-PSZ (Katana UTML). After cementation, the specimens were stored in water for 24 hours and then thermocycled 10 000 times. Dynamic loading (70 N, 200 000 cycles, 1 Hz) was applied to half the specimens. The fracture load was measured by using a universal testing machine. The fracture patterns were analyzed and fractography applied. Two-way ANOVA and the Fisher exact test were used for statistical analysis (α=.05). RESULTS The material and dynamic loading affected the fracture load of the anterior monolithic crowns (P<.05). However, there was no interaction between the material and the dynamic loading (P=.079). Both lithium disilicates had higher fracture loads than 5Y-PSZ (P<.05). The fracture load of each specimen was reduced after dynamic loading (P<.05). Lithium disilicate showed marginal and bulk fractures, and 5Y-PSZ presented catastrophic fractures (P<.001). CONCLUSIONS 5Y-PSZ materials with large grains and low flexural strength may be less resistant to fractures under dynamic loading than lithium disilicates.
Collapse
Affiliation(s)
- Seung-Sik Choo
- Graduate student, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Kyung-Ho Ko
- Assistant Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Yoon-Hyuk Huh
- Associate Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Chan-Jin Park
- Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Lee-Ra Cho
- Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea.
| |
Collapse
|
18
|
Giugliano TS, Zhang Y, Janal MN, Lim CH, Smith RM, Choi M. In vitro comparison of physical characteristics of milled versus printed zirconia discs. J Prosthodont 2023:10.1111/jopr.13778. [PMID: 37776103 PMCID: PMC10980599 DOI: 10.1111/jopr.13778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 09/25/2023] [Accepted: 09/27/2023] [Indexed: 10/01/2023] Open
Abstract
PURPOSE The purpose of this study was to compare the dimensional accuracy, translucency, and biaxial flexural strength of milled zirconia (MZ) versus 3D-printed zirconia (PZ) discs. MATERIALS & METHODS A circular disc measuring 14.0 mm in diameter and 1.20 mm in thickness was designed using computer-aided design (CAD) software. The resulting standard tessellation language (STL) file was used both as a control and to fabricate 36 zirconia (3Y-TZP) disc specimens (n = 36): 18 were milled (group MZ) and 18 were 3D-printed (group PZ). The diameter and thickness of each disc were measured using a digital caliper. Translucency was evaluated using a calibrated dental colorimeter. The flexural strength was determined using the piston-on-three-ball biaxial flexure test. All measurements were done by one blinded examiner. The statistical significance level was set to α = 0.05. RESULTS The MZ discs had significantly more accurate dimensions than the PZ discs in both diameter and thickness when compared to the control CAD software-designed disc. The MZ discs exhibited significantly higher translucency (translucency parameter (TP) = 16.95 ±0.36 vs. 9.24 ±1.98) and biaxial flexural strength (996.16 ±137.37 MPa vs. 845.75 ±266.16 MPa) than the PZ discs. Finally, MZ possessed a significantly higher Weibull modulus relative to PZ. CONCLUSIONS The results showed that the milled specimens achieved better dimensional accuracy and were more translucent, stronger, and less prone to failure than printed specimens.
Collapse
Affiliation(s)
- Thomas S. Giugliano
- Department of Prosthodontics, New York University College of Dentistry, New York, NY
| | - Yu Zhang
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA
| | - Malvin N. Janal
- Department of Epidemiology & Health Promotion, New York University College of Dentistry, New York, NY
| | - Chek Hai Lim
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA
| | - Ruby M. Smith
- Post-Graduate Student, Department of Prosthodontics, New York University College of Dentistry, New York, NY
| | - Mijin Choi
- Department of Prosthodontics, New York University College of Dentistry, New York, NY
| |
Collapse
|
19
|
Yilmaz M, Demir E, Olcay EO. The effects of various scaling instruments on the surface roughness of monolithic zirconia and lithium disilicate. Eur Oral Res 2023; 57:133-137. [PMID: 37929219 PMCID: PMC10622152 DOI: 10.26650/eor.20231109111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 11/30/2022] [Accepted: 12/20/2022] [Indexed: 11/07/2023] Open
Abstract
Purpose This in vitro study aims to evaluate the effects of plastic piezoelectric maintenance tips on the surface roughness of monolithic lithium disilicate and zirconia. Materials and methods Fifty-four lithium disilicate and 54 zirconia disks were prepared with CAD/CAM. On each material, scaling with a stainless-steel curette or with a piezoelectric device using either a steel or plastic tip was conducted. The surface roughness of the materials before and after the instrumentation was measured with a profilometer. The changes in roughness of the materials according to the scaling methods were analyzed with generalized linear models. Mann-Whitney U with Bonferroni correction was used for between-group comparisons. Results The instruments caused surface alterations on both materials (p=0.001), while the roughness change of lithium disilicate and zirconia specimens did not demonstrate any statistically significant difference with each other (p=0.274). However, the curette was found to cause significantly more (p=0.019) roughness change (0.259 ±0.405) on the specimens than the piezoelectric plastic tip (0.060 ±0.238). Conclusion Piezoelectric scalers with plastic tips cause less deterioration on monolithic zirconia and lithium disilicate surfaces when compared to stainless-steel hand curettes.
Collapse
Affiliation(s)
- Mustafa Yilmaz
- Department of Periodontology, Faculty of Dentistry,Biruni University Istanbul,Turkiye
| | - Esra Demir
- Department of Periodontology, Faculty of Dentistry,Bezmialem Vakif University, Istanbul,Turkiye
| | - Emin Orkun Olcay
- Department of Prosthodontics, Faculty of Dentistry,Biruni University, Istanbul,Turkiye
| |
Collapse
|
20
|
Fouda AM, Atta O, Özcan M, Stawarczyk B, Glaum R, Bourauel C. An investigation on fatigue, fracture resistance, and color properties of aesthetic CAD/CAM monolithic ceramics. Clin Oral Investig 2023; 27:2653-2665. [PMID: 36574045 PMCID: PMC10264477 DOI: 10.1007/s00784-022-04833-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Accepted: 12/18/2022] [Indexed: 12/28/2022]
Abstract
OBJECTIVES To evaluate and compare fracture resistance, translucency, and color reproducibility, as well as the effect of aging on the fracture load and color stability of novel monolithic CAD/CAM ceramics. MATERIALS AND METHODS One hundred crowns of uniform thickness were milled from five ceramic blocks (n = 20): partially crystallized lithium disilicate (PLD) and fully crystallized lithium disilicate (FLD), lithium metasilicate (LMS), 4Y-TZP (SMZ), and 5Y-TZP (UMZ) monolithic zirconia. PLD crowns were glazed, LMS was fired, and FLD was polished. SMZ and UMZ crowns were sintered and polished. Crowns were adhesively cemented to epoxy dies. Half of the crowns (n = 10) were subjected to 1.200.000 load cycles with thermal cycling. Color space values L, a, b defined by the Commission Internationale de l´Eclairage (CIELAB) were measured before and after aging, and (∆E) was calculated. Both aged and non-aged specimens were loaded until fracture in a universal testing machine and the fracture load was recorded. X-ray diffraction (XRD) and scanning electron microscope (SEM) fractographic analysis were carried out on fractured fragments of representative samples. For translucency and color reproducibility, 50 rectangular-shaped specimens were fabricated and processed as described previously. Color values were measured over black and white backgrounds, and the translucency parameter (TP) was computed. Using the shade verification mode, (∆E) to shade A3 was calculated. Data were statistically analyzed using one-way and two-way ANOVA, and t-test. RESULTS Aging did not affect fracture resistance significantly (p > 0.05). The highest mean fracture load was obtained for the SMZ and UMZ. A significant color change was observed after aging in all groups. The highest TP was noted for FLD. SMZ and UMZ had the best shade match. CONCLUSIONS Zirconia showed higher fracture resistance and color stability than lithium silicate ceramics. Lithium silicate ceramics were more translucent. The experimental FLD demonstrated high translucency. CLINICAL RELEVANCE Tested ceramics showed sufficient stability to withstand masticatory forces. Characterization of final restorations might be mandatory for better color match.
Collapse
Affiliation(s)
- Ahmed Mahmoud Fouda
- Department of Oral Technology, University Hospital Bonn, Bonn University, Welschnonnenstr. 17, 53111, Bonn, Germany.
- Department of Fixed Prosthodontics, Suez Canal University, Ismailia, Egypt.
| | - Osama Atta
- Department of Fixed Prosthodontics, Suez Canal University, Ismailia, Egypt
| | - Mutlu Özcan
- Division of Dental Biomaterials, Center for Dental Medicine, Clinic for Reconstructive Dentistry, University of Zurich, Zurich, Switzerland
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - Robert Glaum
- Institute of Inorganic Chemistry, Bonn University, Bonn, Germany
| | - Christoph Bourauel
- Department of Oral Technology, University Hospital Bonn, Bonn University, Welschnonnenstr. 17, 53111, Bonn, Germany
| |
Collapse
|
21
|
Alshahrani AM, Lim CH, Kim J, Zhang Y. Transient thermal stresses developed during speed sintering of 3 mol% yttria-stabilized tetragonal zirconia polycrystals. Dent Mater 2023; 39:522-528. [PMID: 37045719 PMCID: PMC10168597 DOI: 10.1016/j.dental.2023.04.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 04/05/2023] [Indexed: 04/14/2023]
Abstract
OBJECTIVES To investigate transient thermal stresses that developed in 3Y-TZP green compacts during speed sintering. METHODS A total of 312 disc-shaped green compacts (Ø17.1 ×1, 1.5, 2, 2.5, 3 mm) were cold-isostatically pressed from 3Y-TZP powder (Zpex, Tosoh Corp.) for speed sintering studies as well as compositional analysis and biaxial flexural strength measurements (both at room temperature and following heating at 90 °C/min to 500 °C). Flexural strength was determined using the piston-on-3-ball method. Phase assemblies were analyzed using the X-ray diffraction method. Effects of heating/cooling rates on transient stresses were investigated by conducting definitive sintering studies to determine the threshold for fracture. Finite element analysis (FEA) was used to validate the experimental findings using measured thermomechanical properties. RESULTS The bulk and relative density of the green compact were 2.95 ± 0.03 g/cm3 and 48.52% ± 0.45%. The flexural strength was drastically decreased from 10.3 ± 0.4 MPa to 1.09 ± 0.07 MPa following heating at 90 °C/min to 500 °C. The monoclinic and tetragonal contents were 54.9% and 45.1%, respectively. The threshold for fracture was located at 500 °C during the first heating stage with a 90 °C/min heating rate in specimens of 2.5 mm thickness or greater. No fractures occurred in the second heating stage and cooling phase. The FEA estimated that the principal transient tensile stress was ∼1.14 MPa at 500 °C during the heating phase, which exceeded the corresponding flexural strength (1.09 ± 0.07 MPa). SIGNIFICANCE Advanced FEA methods are an accurate and efficient tool to analyze the history of transient stresses during sintering of ceramic dental restorations.
Collapse
Affiliation(s)
- Abdulaziz M Alshahrani
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Chek Hai Lim
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Jeongho Kim
- Department of Civil and Environmental Engineering, University of Connecticut, 261 Glenbrook Rd, U-3037, Storrs, CT 06269, USA
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
| |
Collapse
|
22
|
Zhou M, Zhang X, Zhang Y, Li D, Zhao Z, Wang Q, Tang K, Niu L, Wang F. Construction of Nanostructured Glass-Zirconia to Improve the Interface Stability of Dental Bilayer Zirconia. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:678. [PMID: 36839046 PMCID: PMC9960043 DOI: 10.3390/nano13040678] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 02/05/2023] [Accepted: 02/06/2023] [Indexed: 06/18/2023]
Abstract
Bilayer zirconia restoration is one of the most commonly used restorations in dental practice, but the high frequency of the cohesive/adhesive fracture of veneered porcelain is still a problem. This paper focuses on the development of nanostructured glass-zirconia to improve the interface stability of dental zirconia substrate and veneered porcelain. A novel SiO2-Li2O-Al2O3 (SLA) glass was prepared and infiltrated into the surface of fully sintered dental zirconia to obtain nanostructured glass-zirconia structure. The prepared glass-zirconia was analyzed with scanning electron microscopes (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction spectroscopy (XRD). The wettability, roughness and 3D morphology of zirconia were altered, and shear bonding strength (SBS) test demonstrated almost double increase in SBS values of the nanostructured glass-zirconia structure. The failure modes and microstructure characteristics also verified the improved interfacial stability. This investigation provides a promising method for enhancing the structural stability of bilayer zirconia restorations.
Collapse
Affiliation(s)
- Ming Zhou
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Xiaoyu Zhang
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Yaming Zhang
- School of Science, Xi’an University of Posts and Telecommunications, Xi’an 710061, China
| | - Ding Li
- School of Science, Xi’an University of Posts and Telecommunications, Xi’an 710061, China
| | - Zhe Zhao
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Qing Wang
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Kai Tang
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Lina Niu
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Fu Wang
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| |
Collapse
|
23
|
Ziębowicz A, Oßwald B, Kern F, Schwan W. Effect of Simulated Mastication on Structural Stability of Prosthetic Zirconia Material after Thermocycling Aging. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1171. [PMID: 36770181 PMCID: PMC9920019 DOI: 10.3390/ma16031171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 01/25/2023] [Accepted: 01/26/2023] [Indexed: 06/18/2023]
Abstract
Recent trends to improve the aesthetic properties-tooth-like color and translucency-of ceramic dental crowns have led to the development of yttria-stabilized zirconia (Y-TZP) materials with higher stabilizer content. These 5Y-TZP materials contain more cubic or t' phase, which boosts translucency. The tradeoff as a consequence of a less transformable tetragonal phase is a significant reduction of strength and toughness compared to the standard 3Y-TZP composition. This study aims at determining the durability of such 5Y-TZP crowns under lab conditions simulating the conditions in the oral cavity during mastication and consumption of different nutrients. The test included up to 10,000 thermal cycles from 5 °C to 55 °C "from ice cream to coffee" and a chewing simulation representing 5 years of use applying typical loads. The investigation of the stress-affected zone at the surface indicates only a very moderate phase transformation from tetragonal to monoclinic after different varieties of testing cycles. The surface showed no indication of crack formation after testing. It can, therefore, be assumed that over the simulated period, dental crowns of 5Y-TZP are not prone to fatigue failure.
Collapse
Affiliation(s)
- Anna Ziębowicz
- Department of Biomaterials and Medical Devices Engineering, Silesian University of Technology, 41-800 Zabrze, Poland
| | - Bettina Oßwald
- Institute for Manufacturing Technologies of Ceramic Components and Composites (IFKB), University of Stuttgart, D-70569 Stuttgart, Germany
| | - Frank Kern
- Institute for Manufacturing Technologies of Ceramic Components and Composites (IFKB), University of Stuttgart, D-70569 Stuttgart, Germany
| | - Willi Schwan
- Institute for Manufacturing Technologies of Ceramic Components and Composites (IFKB), University of Stuttgart, D-70569 Stuttgart, Germany
| |
Collapse
|
24
|
Bruhnke M, Awwad Y, Müller WD, Beuer F, Schmidt F. Mechanical Properties of New Generations of Monolithic, Multi-Layered Zirconia. MATERIALS (BASEL, SWITZERLAND) 2022; 16:276. [PMID: 36614613 PMCID: PMC9822212 DOI: 10.3390/ma16010276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 12/20/2022] [Accepted: 12/21/2022] [Indexed: 06/17/2023]
Abstract
New monolithic multi-layered zirconia restorations are gaining popularity due to their excellent aesthetic properties. However, current knowledge of these newest multi-layer ceramics in terms of mechanical properties is scarce. Three monolithic, multi-layered zirconia materials (Katana, Kuraray Noritake, Japan) were selected for comparison: High Translucent Multi-layered zirconia (HTML), Super Translucent Multi-layered zirconia (STML) and Ultra Translucent Multi-layered zirconia (UTML). Fifteen specimens per group were cut from pre-sintered blocs in each of the four layers (L1, L2, L3, L4) and in different thicknesses (0.4 mm, 0.8 mm and 1.2 mm). Critical fracture load (Fcf) was recorded in 3-point-bending. Flexural strength (σ) in MPa, Vickers hardness (HV) in N/mm2, fracture toughness (KIc) in MPa*m1/2, Weibull Modulus (m) and characteristic Weibull strength (σw) in MPa were assessed. Statistical analysis was performed using ANOVA analysis. FS and KIc were significantly higher (p < 0.05) for Katana™ HTML (652.85 ± 143.76−887.64 ± 118.95/4.25 ± 0.43−5.01 ± 0.81) in comparison to Katana™ STML (280.17 ± 83.41−435.95 ± 73.58/3.06 ± 0.27−3.84 ± 0.47) and UTML (258.25 ± 109.98−331.26 ± 56.86/2.35 ± 0.31−2.94 ± 0.33), with no significant differences between layers and layer thicknesses. The range of indications should be carefully considered when selecting the type of monolithic zirconia for fabrication of dental restorations, as materials widely differ in mechanical properties.
Collapse
|
25
|
De Angelis F, Buonvivere M, Sorrentino E, Rondoni GD, D’Arcangelo C. Wear Properties of Conventional and High-Translucent Zirconia-Based Materials. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7324. [PMID: 36295389 PMCID: PMC9606984 DOI: 10.3390/ma15207324] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 10/13/2022] [Accepted: 10/18/2022] [Indexed: 06/16/2023]
Abstract
This study investigated the two-body wear resistance of a first generation 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP), a second generation 3Y-TZP, a third generation 4 mol% yttria partially stabilized zirconia (4Y-PSZ), a 5 mol% yttria partially stabilized zirconia (5Y-PSZ), and a type III gold alloy (Aurocast 8), performed using opposing antagonistic cusps made out of the same material. Eight cylindrical specimens were prepared for each material (n = 8) for a total of forty specimens (N = 40). Conical cusps were fabricated for each material. Each cylinder−cusp pair was arranged inside a two-axis chewing simulator over up to 360,000 loading cycles. The wear resistance was analyzed by measuring the vertical substance loss (mm) and the volume loss (mm3). The antagonist wear (mm) was recorded before and after the wear test to evaluate the linear difference. Statistical analysis was performed using one-way analysis of variance (ANOVA); multiple comparisons were performed according to Tukey’s method. No statistically significant differences (p > 0.05) among the first generation 3Y-TZP, second generation 3Y-TZP, and 4Y-PSZ wear were found. 5Y-PSZ showed statistically significant higher wear compared to other the zirconias. Aurocast 8 displayed the highest values in terms of vertical wear, antagonist cusp wear, and volumetric loss. Although still not statistically comparable, the wear behavior of the latest 5Y-PSZ was the closest to the widely recognized gold standard represented by the type III gold alloy.
Collapse
Affiliation(s)
- Francesco De Angelis
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Science, School of Dentistry, “G. D’Annunzio” University of Chieti, 66100 Chieti, Italy
| | - Matteo Buonvivere
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Science, School of Dentistry, “G. D’Annunzio” University of Chieti, 66100 Chieti, Italy
| | - Edoardo Sorrentino
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Science, School of Dentistry, “G. D’Annunzio” University of Chieti, 66100 Chieti, Italy
| | | | - Camillo D’Arcangelo
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Science, School of Dentistry, “G. D’Annunzio” University of Chieti, 66100 Chieti, Italy
| |
Collapse
|
26
|
Bocam K, Anunmana C, Eiampongpaiboon T. Grain size, crystalline phase and fracture toughness of the monolithic zirconia. J Adv Prosthodont 2022; 14:285-293. [PMID: 36452361 PMCID: PMC9672698 DOI: 10.4047/jap.2022.14.5.285] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 09/03/2022] [Accepted: 09/22/2022] [Indexed: 08/27/2023] Open
Abstract
PURPOSE This study evaluated the relationship among translucency, crystalline phase, grain size, and fracture toughness of zirconia. MATERIALS AND METHODS Four commercial zirconia - Prettau®Anterior® (PA), Prettau® (P), InCorisZI (ZI), and InCorisTZI (TZI)- were selected for this study. The bar specimens were prepared to determine fracture toughness by using chevron notched beam method with four-point bending test. The grain size was evaluated by a mean linear intercept method using a scanning electron microscope. X-ray diffraction and Rietveld refinement were performed to evaluate the amount of tetragonal and cubic phases of zirconia. Contrast ratio (CR) was measured to investigate the level of translucency. RESULTS PA had the lowest fracture toughness among other groups (P < .05). In addition, the mean fracture toughness of P was significantly less than that of ZI, but there was no difference compared with TZI. Regarding grain size measurement, PA had the largest average grain size among the groups. P obtained larger grain size than ZI and TZI (P < .05). However, there was no significant difference between ZI and TZI. Moreover, PA had the lowest CR value compared with the other groups (P < .05). This means PA was the most translucent material in this study. Rietveld refinement found that PA presented the greatest percentage of cubic phase, followed by TZI, ZI, and P, respectively. CONCLUSION The different approaches are used by manufacturers to fabricate various types of translucent zirconia with different levels of translucency and mechanical properties, which should be concerned for material selection for successful clinical outcome.
Collapse
Affiliation(s)
- Kodchakorn Bocam
- Residency Training Program, Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Chuchai Anunmana
- Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | | |
Collapse
|
27
|
Benalcázar Jalkh EB, Bergamo ETP, Campos TMB, de Araújo-Júnior ENS, Lopes ACO, Tebcherani SM, Yamaguchi S, Genova LA, Gierthmuehlen PC, Witek L, Coelho PG, Bonfante EA. Stability of fatigued and aged ZTA compared to 3Y-TZP and Al 2O 3 ceramic systems. J Mech Behav Biomed Mater 2022; 135:105451. [PMID: 36162164 DOI: 10.1016/j.jmbbm.2022.105451] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 08/31/2022] [Accepted: 09/02/2022] [Indexed: 10/31/2022]
Abstract
To evaluate the effect of fatigue and aging on the crystalline content and reliability of a zirconia-toughened-alumina (ZTA) composite compared to its individual counterpart materials (3Y-TZP and Al2O3). Thirty-six disc-shaped specimens per group were obtained to comply with ISO 6872:2015. Crystalline content, microstructure and reliability of experimental groups were evaluated in four stages: 1) immediate; 2) aged; 3) fatigued; 4) aged + fatigue. Aging was performed in autoclave and Step-Stress-Accelerated-Life-Testing (SSALT) was performed using three stress profiles. Weibull statistics were used to determine Weibull parameters and life-expectancy. A significant increase in monoclinic phase in 3Y-TZP was observed after aging (19.31%), fatigue (17.88%) and aging + fatigue (55.81%), while ZTA evidenced minimal variation among all conditions (<5.69%). 3Y-TZP presented higher reliability than ZTA at 300 and 500 MPa, and ZTA outperformed Al2O3 at the same stress missions. None of the ceramics yielded acceptable reliability at 800 MPa. A higher characteristic strength was observed for 3Y-TZP, followed by ZTA and Al2O3. While after aging ZTA and Al2O3 remained stable, 3Y-TZP exhibited a significant increase in the characteristic stress. Aging did not affect the reliability of ZTA and Al2O3. 3Y-TZP demonstrated an increase in monoclinic content and characteristic strength after aging.
Collapse
Affiliation(s)
- Ernesto B Benalcázar Jalkh
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil; Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA.
| | - Edmara T P Bergamo
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil; Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA
| | - Tiago M B Campos
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil
| | - Everardo N S de Araújo-Júnior
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil
| | - Adolfo C O Lopes
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil
| | - Sérgio M Tebcherani
- Federal University of Technology, Paraná, Department of Production Engineering, Av. Monteiro Lobato km 04, 84016-210, Ponta Grossa, PR, Brazil
| | - Satoshi Yamaguchi
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry, Suita, Osaka, Japan
| | - Luis A Genova
- Nuclear and Energy Research Institute, IPEN, SP, Brazil
| | - Petra C Gierthmuehlen
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany
| | - Lukasz Witek
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA; Department of Biomedical Engineering, NYU Tandon School of Engineering, New York University, Brooklyn, NY, USA
| | - Paulo G Coelho
- Department of Surgery, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Estevam A Bonfante
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil
| |
Collapse
|
28
|
Wear behavior and abrasiveness of monolithic CAD/CAM ceramics after simulated mastication. Clin Oral Investig 2022; 26:6593-6605. [PMID: 35819543 PMCID: PMC9643261 DOI: 10.1007/s00784-022-04611-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Accepted: 06/28/2022] [Indexed: 11/30/2022]
Abstract
Objectives To evaluate the wear resistance and abrasiveness of monolithic CAD/CAM ceramics. Materials and methods Rectangular-shaped specimens (12 mm × 6.5 mm × 1.5 mm) were sectioned from the following CAD/CAM blocks (n = 10); partially crystallized lithium disilicate (PLD), experimental fully crystallized lithium disilicate (FLD), zirconia-reinforced lithium silicate (ZLS), super-translucent monolithic zirconia (SMZ), and ultra-translucent monolithic zirconia (UMZ). Silicon carbide papers were used to mechanically flatten and polish the surfaces. PLD specimens were subjected to a combined crystallization/glazing firing cycle. Ceramic specimens were mounted to the wear device and tested for 200,000 cycles against human premolars at 20 N force and 2 mm sliding distance. Artificial saliva was used as a lubricant. The teeth were scanned using micro-CT before and after the wear test and the generated models were overlapped to determine the volumetric tooth loss. Before and after the test, specimens’ weights and surface roughness (Ra) values were measured, and the differences were calculated. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) were utilized for microstructural and chemical analysis. Statistical analysis was performed using one-way ANOVA or an equivalent test for non-parametric results. Significance level was set at P ≤ 0.05. Results The type of ceramic material affected the ceramic and antagonist wear rates (P < 0.001). PLD and ZLS had the highest ceramic and antagonist wear, whereas UMZ and SMZ demonstrated the lowest wear values. The FLD group showed comparable antagonist wear and significantly less ceramic wear than PLD and ZLS. Conclusions Monolithic zirconia demonstrated the best wear resistance and least abrasiveness to the antagonist. The experimental lithium disilicate was more wear-resistant than other glass–ceramic groups. Clinical relevance Monolithic zirconia is wear-resistant and gentle on the antagonist. In contrast, glass–ceramics are more abrasive to enamel. Supplementary Information The online version contains supplementary material available at 10.1007/s00784-022-04611-w.
Collapse
|
29
|
Chopra D, Jayasree A, Guo T, Gulati K, Ivanovski S. Advancing dental implants: Bioactive and therapeutic modifications of zirconia. Bioact Mater 2022; 13:161-178. [PMID: 35224299 PMCID: PMC8843948 DOI: 10.1016/j.bioactmat.2021.10.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 08/22/2021] [Accepted: 10/06/2021] [Indexed: 12/16/2022] Open
Abstract
Zirconium-based implants have gained popularity in the dental implant field owing to their corrosion resistance and biocompatibility, attributed to the formation of a native zirconia (ZrO2) film. However, enhanced bioactivity and local therapy from such implants are desirable to enable the earlier establishment and improved long-term maintenance of implant integration, especially in compromised patient conditions. As a result, surface modification of zirconium-based implants have been performed using various physical, chemical and biological techniques at the macro-, micro-, and nano-scales. In this extensive review, we discuss and detail the development of Zr implants covering the spectrum from past and present advancements to future perspectives, arriving at the next generation of highly bioactive and therapeutic nano-engineered Zr-based implants. The review provides in-depth knowledge of the bioactive/therapeutic value of surface modification of Zr implants in dental implant applications focusing on clinical translation.
Collapse
Affiliation(s)
| | | | | | - Karan Gulati
- Corresponding authors. School of Dentistry, University of Queensland, 288 Herston Road, Herston QLD, 4006, Australia.
| | - Sašo Ivanovski
- Corresponding authors. School of Dentistry, University of Queensland, 288 Herston Road, Herston QLD, 4006, Australia.
| |
Collapse
|
30
|
Lim CH, Vardhaman S, Reddy N, Zhang Y. Composition, processing, and properties of biphasic zirconia bioceramics: relationship to competing strength and optical properties. CERAMICS INTERNATIONAL 2022; 48:17095-17103. [PMID: 37701057 PMCID: PMC10497227 DOI: 10.1016/j.ceramint.2022.02.265] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
Abstract
A study is made of relationships between composition, processing, structure and properties of biphasic zirconia bioceramics. The focus is on zirconia compositions with different yttria dopant contents used in modern dental restorations, namely 3 - 5 mol% yttria stabilized zirconia (3YSZ, 4YSZ, and 5YSZ). Crystallographies and densities are surveyed, sintering conditions examined, and microstructures characterized. Strength and optical tests are conducted on each YSZ, and dependencies on sintering temperature, cubic content and grain size analyzed. Strength correlates with the amount of tetragonal zirconia (t-ZrO2) crystals with large lattice distortions (tetragonality). YSZ translucency correlates with content of cubic zirconia (c-ZrO2) and t-ZrO2 with low levels of tetragonality. Consistent with literature reporting, the materials rank in decreasing order 3YSZ, 4YSZ to 5YSZ for strength but increasing order for translucency. However, for a given composition, the data suggest that the strengths of densely sintered 3YSZ and 4YSZ actually increase with translucency, although that of 5YSZ remains undiminished. These trends are in apparent contradiction to prevailing experience, and offer potential future processing routes to optimization of clinical materials.
Collapse
Affiliation(s)
- Chek Hai Lim
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, PA 19104, USA
| | - Sonaj Vardhaman
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, PA 19104, USA
| | - Niyati Reddy
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, PA 19104, USA
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, PA 19104, USA
| |
Collapse
|
31
|
Dimitriadis K, Sfikas AK, Kamnis S, Tsolka P, Agathopoulos S. Influence of heat treatment on the microstructure and the physical and mechanical properties of dental highly translucent zirconia. J Adv Prosthodont 2022; 14:96-107. [PMID: 35601351 PMCID: PMC9095450 DOI: 10.4047/jap.2022.14.2.96] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 04/09/2022] [Accepted: 04/12/2022] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Microstructural and physico-mechanical characterization of highly translucent zirconia, prepared by milling technology (CAD-CAM) and repeated firing cycles, was the main aim of this in vitro study. MATERIALS AND METHODS Two groups of samples of two commercial highly-translucent yttria-stabilized dental zirconia, VITA YZ-HTWhite (Group A) and Zolid HT + White (Group B), with dimensions according to the ISO 6872 "Dentistry - Ceramic materials", were prepared. The specimens of each group were divided into two subgroups. The specimens of the first subgroups (Group A1 and Group B1) were merely the sintered specimens. The specimens of the second subgroups (Group A2 and Group B2) were subjected to 4 heat treatment cycles. The microstructural features (microstructure, density, grain size, crystalline phases, and crystallite size) and four mechanical properties (flexural strength, modulus of elasticity, Vickers hardness, and fracture toughness) of the subgroups (i.e. before and after heat treatment) were compared. The statistical significance between the subgroups (A1/A2, and B1/B2) was evaluated by the t-test. In all tests, P values smaller than 5% were considered statistically significant. RESULTS A homogenous microstructure, with no residual porosity and grains sized between 500 and 450 nm for group A and B, respectively, was observed. Crystalline yttria-stabilized tetragonal zirconia was exclusively registered in the X-ray diffractograms. The mechanical properties decreased after the heat treatment procedure, but the differences were not statistically significant. CONCLUSION The produced zirconia ceramic materials can be safely (i.e., according to the ISO 6872) used in extensive fixed prosthetic restorations, such as substructure ceramics for three-unit prostheses involving the molar restoration and substructure ceramics for prostheses involving four or more units. Consequently, milling technology is an effective manufacturing technology for producing zirconia substructures for dental fixed all-ceramic prosthetic restorations.
Collapse
Affiliation(s)
- Konstantinos Dimitriadis
- Division of Dental Technology, Department of Biomedical Sciences, University of West Attica, Athens, Greece
| | | | - Spyros Kamnis
- Castolin Eutectic-Monitor Coatings Ltd, Newcastle, United Kingdom
| | - Pepie Tsolka
- Division of Dental Technology, Department of Biomedical Sciences, University of West Attica, Athens, Greece
| | - Simeon Agathopoulos
- Department of Materials Science and Engineering, School of Engineering, University of Ioannina, Ioannina, Greece
| |
Collapse
|
32
|
Tokunaga J, Ikeda H, Nagamatsu Y, Awano S, Shimizu H. Castable polymer-infiltrated ceramic network composite for training model tooth with compatible machinability to human enamel. Dent Mater J 2022; 41:520-526. [PMID: 35264545 DOI: 10.4012/dmj.2021-299] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study aimed to develop a novel polymer-infiltrated ceramic network (PICN) composite fabricated via a slip-casting method for a dental training model tooth with machinability compatible to human enamel. A PICN model tooth comprised of silica/acrylic-resin was fabricated via the slip-casting method. A commercial resin-based model tooth and human enamel were used as the control sample. The samples were evaluated based on Vickers hardness, inorganic contents, density, and machinability. The machinability was characterized by a grinding amount obtained from the grinding test using a device equipped with a dental micromotor handpiece with a diamond bur. The properties of the PICN model tooth yielded a silica content of 84.7% and a density of 1.99 g/cm3, and its Vickers hardness (312) was comparable with that of enamel (348). The grinding amount was comparable with that of enamel. The castable PICN model tooth was compatible to enamel in terms of hardness and machinability.
Collapse
Affiliation(s)
- Jumpei Tokunaga
- Division of Clinical Education Development and Research, Department of Oral Functions, Kyushu Dental University.,Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| | - Shuji Awano
- Division of Clinical Education Development and Research, Department of Oral Functions, Kyushu Dental University
| | - Hiroshi Shimizu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| |
Collapse
|
33
|
Bozogullari HN, Citir Yucel H, Ustun O, Akan T, Ozer F. The effect of nonthermal argon plasma surface treatment on the fracture resistance of monolithic zirconia restorations containing tetragonal and cubic grains. J Oral Sci 2022; 64:124-128. [PMID: 35173098 DOI: 10.2334/josnusd.21-0446] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
PURPOSE The aim of this study was to investigate the effect of nonthermal argon plasma (NP) surface treatment on the fracture resistance of monolithic zirconia restorations with different microstructures. METHODS Twenty restorations were prepared from each of two tetragonal and two cubic zirconia materials (80 restorations in total). The restorations were then divided into two subgroups (n = 10) for each material according to the surface treatment applied: air abrasion or NP. The surface topography of the treated groups was examined using a scanning electron microscope. All restorations were fixed to metal dies with resin cement, subjected to thermal cycling, and then underwent fracture resistance testing with a universal testing device. Two-way ANOVA and Bonferroni tests were used for statistical analysis of the data (α = 0.05). RESULTS The type of surface treatment and the type of zirconia material were shown to significantly affect the fracture resistance of the restorations. The air-abraded groups showed significantly higher fracture resistance (N) than the NP groups (P < 0.001). CONCLUSION The results of this study suggest that air abrasion surface treatment has a more favorable effect on the fracture resistance of tetragonal and cubic zirconia restorations than NP surface treatment.
Collapse
Affiliation(s)
| | - Hande Citir Yucel
- Department of Prosthodontics, Faculty of Dentistry, Alanya Alaaddin Keykubat University
| | - Ozlem Ustun
- Department of Prosthodontics, Faculty of Dentistry, Akdeniz University
| | - Tamer Akan
- Department of Physics, Faculty of Science and Letters, Eskisehir Osmangazi University
| | - Fusun Ozer
- Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine
| |
Collapse
|
34
|
Prospective Clinical Evaluation of Posterior Third-Generation Monolithic Zirconia Crowns Fabricated with Complete Digital Workflow: Two-Year Follow-Up. MATERIALS 2022; 15:ma15020672. [PMID: 35057389 PMCID: PMC8780337 DOI: 10.3390/ma15020672] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/06/2022] [Accepted: 01/13/2022] [Indexed: 12/11/2022]
Abstract
Clinical studies on the behavior of posterior translucent monolithic zirconia restorations are lacking. We assessed the clinical outcome and survival rate of posterior third-generation monolithic zirconia crowns over a 2-year period. A total of 24 patients, requiring 30 posterior full-contour restorations were selected. All abutments were scanned, and crowns were milled and cemented with a self-adhesive dual cure cement. Crowns were assessed using the California Dental Association’s criteria. Gingival status was assessed by evaluating the gingival index, plaque index, periodontal probing depth of the abutments and control teeth, and the margin index of the abutment teeth. Statistical analyses were performed using the Friedman and the Wilcoxon signed-rank tests. During the 2-year follow-up, no biological or mechanical complications were observed, and the survival and success rate was 100%. All restorations ranked as satisfactory throughout the follow-up period. The gingival index and plaque index were worse at the end of the 2-year follow-up. The margin index was stable during the 2 years of clinical service. No significant differences were recorded in periodontal parameters between crowns and control teeth. Third-generation monolithic zirconia could be a reliable alternative to posterior metal–ceramic and second-generation monolithic zirconia posterior crowns.
Collapse
|
35
|
AlMutairi R, AlNahedh H, Maawadh A, Elhejazi A. Effects of Different Air Particle Abrasion Protocols on the Biaxial Flexural Strength and Fractography of High/Ultra-Translucent Zirconia. MATERIALS (BASEL, SWITZERLAND) 2021; 15:244. [PMID: 35009388 PMCID: PMC8745783 DOI: 10.3390/ma15010244] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/22/2021] [Accepted: 12/28/2021] [Indexed: 06/14/2023]
Abstract
In this study, the biaxial flexural strength (BFS) and fractography of high/ultra-translucent monolithic zirconia ceramics subjected to different mechanical surface pretreatments were evaluated. A total of 108 disc-shaped samples (12 mm diameter, 1.2 mm thickness) of three zirconia materials (5Y-ZP KATANA Zirconia UTML (ML), 3Y-TZP DD Bio ZX2 (DB), and 5Y-ZP DD cube X2 (DC)) were used. The BFS was investigated after subjecting the samples to surface treatment using air abrasion particles of two types (aluminum oxide or glass microbeads). The data were analyzed using two-way analysis of variance, followed by Scheffe's post hoc test for multiple comparisons. The mean ± standard deviation BFS for DB was highest after treatment with 50 µm Al2O3 (1626.05 ± 31.9 MPa), with lower values being observed following treatment with 50 µm glass microbeads (1399.53 ± 24.2 MPa) and in the control sample (1198.51 ± 21.1 MPa). The mean ± standard deviation (SD) BFSs for DC and ML were the highest in the control groups. Surface air abrasion with 50 µm Al2O3 particles and 2 bar pressure is recommended for 3Y-TZP translucent zirconia, while no abrasion of 5Y-ZP translucent zirconia ceramic.
Collapse
|
36
|
Rodrigues CS, Dhital S, Kim J, May LG, Wolff MS, Zhang Y. Residual stresses explaining clinical fractures of bilayer zirconia and lithium disilicate crowns: A VFEM study. Dent Mater 2021; 37:1655-1666. [PMID: 34481666 DOI: 10.1016/j.dental.2021.08.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 08/24/2021] [Accepted: 08/25/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To understand the stress development in porcelain-veneered zirconia (PVZ) and porcelain-veneered lithium disilicate (PVLD) crowns with different veneer/core thickness ratios and cooling rates. To provide design guidelines for better performing bilayer restorations with the aid of Viscoelastic Finite Element Method (VFEM). METHODS The VFEM was validated by comparing the predicted residual stresses with experimental measurements. Then, the model was used to predict transient and residual stresses in the two bilayer systems. Models with two different veneer/core thickness ratios were prepared (2:1 and 1:1) and two cooling protocols were simulated (Fast: ∼300 °C/min, Slow: ∼30 °C/min) using the heat transfer module, followed by stress analysis in ABAQUS. The physical properties of zirconia, lithium disilicate, and the porcelains used for the simulations were determined as a function of temperature. RESULTS PVLD showed lower residual stresses than PVZ. The maximum tensile stresses in PVZ were observed in the cusp area, whereas those in PVLD were located in the central fossa. The 1:1 thickness ratio decreased stresses in both layers of PVZ. Slow cooling slightly decreased residual stresses in both systems. However, the cooling rate effect was more evident in transient stresses. SIGNIFICANCE Slow cooling is preferable for both systems. A thinner porcelain layer over zirconia lowers stresses throughout the restoration. The different stress distributions between PVZ and PVLD may affect their failure modes. Smaller mismatches in modulus, CTE, and specific heat between the constituents, and the use of low Tg porcelains can effectively reduce the deleterious transient and residual tensile stresses in bilayer restorations.
Collapse
Affiliation(s)
- Camila S Rodrigues
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University, 777 Eng. Francisco José Longo Av, 12245-000, São José dos Campos, SP, Brazil
| | - Sukirti Dhital
- Department of Civil and Environmental Engineering, University of Connecticut, 261 Glenbrook Rd., U-3037, Storrs, CT 06269, USA
| | - Jeongho Kim
- Department of Civil and Environmental Engineering, University of Connecticut, 261 Glenbrook Rd., U-3037, Storrs, CT 06269, USA
| | - Liliana Gressler May
- Department of Restorative Dentistry, School of Dentistry, Federal University of Santa Maria, 1000 Roraima Av., T Street, Building 26F, 97105-900, Santa Maria, RS, Brazil
| | - Mark S Wolff
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, 240 S. 40th Street, Philadelphia, PA 19104, USA
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, 240 S. 40th Street, Philadelphia, PA 19104, USA.
| |
Collapse
|
37
|
Al-Qaysi SH, Saleh ARM, El-Damanhoury HM. Fracture resistance and failure mode of layered translucent zirconia with different crown designs. Dent Mater J 2021; 41:54-59. [PMID: 34483200 DOI: 10.4012/dmj.2021-051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study investigated the impact of different veneering design on the fracture resistance and failure mode of layered translucent zirconia crowns, compared to the full monolithic zirconia crowns. Ninety crowns with different designs were divided into six groups (n=15); one fully contoured monolithic crown (FMC), one fully veneered with porcelain (FVC), or four partially veneered designs. All crowns were thermo-cycled, and then loaded to failure in a universal testing machine. The fracture resistance (N) and fracture modes were assessed. One-way ANOVA was performed followed by Tukey's multiple comparison (α<0.05). Results demonstrated that all the tested partially veneered designs exhibited enhanced fracture resistances and were comparable to that of the full-contour monolithic translucent zirconia crowns.
Collapse
Affiliation(s)
- Saif H Al-Qaysi
- Department of Clinical Sciences, College of Dentistry, Ajman University
| | | | - Hatem M El-Damanhoury
- Department of Preventive and Restorative Dentistry, College of Dental Medicine, University of Sharjah
| |
Collapse
|
38
|
Nanoscale physico-mechanical properties of an aging resistant ZTA composite. J Mech Behav Biomed Mater 2021; 123:104690. [PMID: 34385065 DOI: 10.1016/j.jmbbm.2021.104690] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 06/26/2021] [Accepted: 07/02/2021] [Indexed: 11/21/2022]
Abstract
OBJECTIVE To characterize the effects of aging on the nanomechanical properties and 3D surface topographical parameters of an experimental Zirconia Toughened Alumina (ZTA) composite compared to its respective individual counterpart materials. METHODS Disk-shaped specimens comprised of three material groups were processed: 1) ZTA 70/30 (70% alumina reinforced with 30% second-generation 3Y-TZP); 2) Zpex (Second-generation 3Y-TZP), and; 3) Al2O3 (High purity Alumina) (n = 10/material, 12 × 1 mm). After synthesis, ceramic powders were pressed, the green-body samples were sintered and polished. Nanoindentation testing was performed to record elastic modulus (E) and hardness (H). Interferometry was utilized to assess 3D surface roughness parameters (Sa, Sq), while X-ray diffraction (XRD) and scanning electron microscope (SEM) assessed the crystalline content and microstructure. All tests were performed before and after simulated aging (134°C, 2.2 bar, 20 h). Statistical analyses were performed using linear mixed-model and least square difference pos-hoc tests (α = 5%). RESULTS XRD spectra indicated increase of monoclinic peaks for Zpex (~18%) relative to ZTA 70/30 (~2.5%) after aging. Additionally, aging did not affect the surface roughness parameters of ZTA 70/30 and Al2O3, although a significant increase in Sa was recorded for Zpex following aging (~90 nm) (p < 0.001). Al2O3 yielded the highest H and E values (H:21 GPa, E: 254 GPa), followed by ZTA 70/30 (H: 13 GPa, E: 214 GPa) and Zpex (H:11 GPa, E: 167 GPa), all significantly different (p < 0.03). CONCLUSION ZTA 70/30 and Al2O3 presented high hydrothermal stability with respect to all evaluated variables, where artificial aging significantly increased the monoclinic content and surface roughness of Zpex.
Collapse
|
39
|
Translucency and flexural strength of translucent zirconia ceramics. J Prosthet Dent 2021; 129:644-649. [PMID: 34303523 DOI: 10.1016/j.prosdent.2021.06.019] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 06/10/2021] [Accepted: 06/11/2021] [Indexed: 11/21/2022]
Abstract
STATEMENT OF PROBLEM Translucent zirconias have been developed with better esthetics than high-strength zirconias by reducing opacity. However, studies on their translucency and strength are sparse. PURPOSE The purpose of this in vitro study was to compare the relationship between translucency and biaxial flexural strength of recently developed high-translucency zirconia, high-strength zirconia, and lithium disilicate ceramics. MATERIAL AND METHODS Disks (n=12) were fabricated for 5 ceramic materials: high-strength zirconia (BruxZir 16 shaded), translucent zirconia (BruxZir Anterior shaded, Katana UTML, Katana STML), and lithium disilicate (IPS e.max, Press HT, and LT). A standard tessellation language (STL) file was designed, and the specimen milled, finished, and glazed according to manufacturer's instructions for each material. The translucency parameter was calculated against black and white backgrounds and white and stump shade with ND4 background by using a spectrophotometer. Biaxial flexural strength was calculated by using the 3-ball test. The load was applied at a crosshead speed of 0.5 mm/min with a 49-N load cell until failure occurred. Translucency parameter and biaxial flexural strength data were analyzed with 1-way analysis of variance (ANOVA). A Tukey honest significant difference multiple comparison test was used to determine significant differences (α=.05). RESULTS The IPS e.max HT was more translucent against both backgrounds (32.85 for black/white and 15.34 for white/stump), while BruxZir 16 was the least translucent (19.78 for B/W and 8.83 for W/S). All groups tested differed in translucency (P<.001) except for BruxZir Anterior and Katana STML, which were not significantly different (P=.052). For biaxial flexural strength, BruxZir 16 had the highest strength (995.44 MPa) and e.max HT, the lowest (186.75 MPa). No significant differences were found between BruxZir anterior and Katana STML, Katana UTML and IPS e.max LT, or IPS e.max LT and IPS e.max HT (P>.05). Translucency parameter values using both backgrounds were strongly correlated (r=0.99). However, biaxial flexural strength values were inversely related to translucency parameter values when using black/white and white/stump shade but with high correlation (r=-0.777 and -0.756 respectively). CONCLUSIONS Lithium disilicate was the most translucent and yet the weakest material, whereas high-strength zirconia was the most opaque ceramic and the strongest. Katana UTML had the highest translucency but was weakest among translucent and high-strength zirconia materials. Overall, translucency was negatively correlated with biaxial flexural strength.
Collapse
|
40
|
Solá-Ruíz MF, Rico-Coderch A, Montiel-Company JM, Fons-Badal C, Verdejo-Solá B, Agustín-Panadero R. Influence of the chemical composition of monolithic zirconia on its optical and mechanical properties. Systematic review and meta-regression. J Prosthodont Res 2021; 66:193-207. [PMID: 34176849 DOI: 10.2186/jpr.jpr_d_20_00218] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This systematic review set out to investigate the influence of chemical composition and specimen thickness of monolithic zirconia on its optical and mechanical properties. Meta-analysis and meta-regression analyzed the effects of variations in percentages of yttrium, aluminum, and specimen thickness of monolithic zirconia. STUDY SELECTION The review followed recommendations put forward in the PRISMA checklist. An electronic search for relevant articles published up to October 2019 was conducted in the Pubmed, Cochrane, Scopus, Scielo, and Web of Science databases, with no language limits and articles published in the last 10 years. From 167 relevant articles; applying inclusion criteria based on the review's PICO question, 26 articles were selected for qualitative synthesis (systematic review) and 24 for quantitative synthesis (meta-analysis). Experimental in vitro studies published were selected and their quality was assessed using the modified Consort scale for in vitro studies of dental materials. RESULTS The variables yttrium, aluminum and thickness were analyzed in random effects models, observing high heterogeneity ( > 75%), and finding statistically significant influences on the properties of monolithic zirconia (p<0.05). CONCLUSIONS Within the review's limitations, it may be concluded that variations in the percentage of yttrium and aluminum influence the optical and mechanical properties of monolithic zirconia, making it more or less esthetic and resistant in relation to each variable. The clinical implications of these findings can help select the most appropriate type of zirconia to meet the different clinical needs when restoring different regions (posterior or anterior).
Collapse
Affiliation(s)
| | - Aitana Rico-Coderch
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia
| | | | - Carla Fons-Badal
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia
| | - Blanca Verdejo-Solá
- Department of Medicine, Faculty of Medicine and Dentistry, Universidad Cardenal Herrera-CEU, Valencia
| | - Rubén Agustín-Panadero
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia
| |
Collapse
|
41
|
Nejat AH, Dupree P, Kee E, Xu X, Zakkour W, Odom M, Bruggers K, Mascarenhas F. Effect of Endodontic Access Preparation on Fracture Load of Translucent versus Conventional Zirconia Crowns with Varying Occlusal Thicknesses. J Prosthodont 2021; 30:706-710. [DOI: 10.1111/jopr.13337] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/14/2021] [Indexed: 11/29/2022] Open
Affiliation(s)
- Amir H. Nejat
- Prosthodontics Department Louisiana State University Health Science Center, School of Dentistry New Orleans LA
| | - Peter Dupree
- Comprehensive Dentistry and Biomaterials Department Louisiana State University Health Science Center, School of Dentistry New Orleans LA
| | - Edwin Kee
- Prosthodontics Department Louisiana State University Health Science Center, School of Dentistry New Orleans LA
| | - Xiaoming Xu
- Oral and Craniofacial Biology Department, Division of Biomaterials Louisiana State University Health Science Center, School of Dentistry New Orleans LA
| | - Wael Zakkour
- Prosthodontics Department Louisiana State University Health Science Center, School of Dentistry New Orleans LA
| | - Mark Odom
- Endodontics Department Louisiana State University Health Science Center, School of Dentistry New Orleans LA
| | - Karen Bruggers
- Prosthodontics Department Louisiana State University Health Science Center, School of Dentistry New Orleans LA
| | - Faye Mascarenhas
- Prosthodontics Department Louisiana State University Health Science Center, School of Dentistry New Orleans LA
| |
Collapse
|
42
|
Mešić K, Majnarić I, Mehulić K. Effect of Aging on the Microstructure and Optical Properties of Translucent ZrO 2 Ceramics. Acta Stomatol Croat 2021; 55:114-128. [PMID: 34248145 PMCID: PMC8255040 DOI: 10.15644/asc55/2/1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 05/31/2021] [Indexed: 02/04/2023] Open
Abstract
Objectives The development and placement of translucent zirconia ceramics on the dental materials market is in full swing. This research aimed to investigate how aging protocols affect the microstructure, color parameters and translucency of a new-generation monolithic zirconia ceramic. Material and methods Translucent zirconia ceramics KATANA-Zirconia STML with different surface treatments (as sintered - control, glazed, polished) was tested using two aging protocols (hydrothermal degradation in autoclave at 134 °C and 2 bars for three hours, chemical degradation in four-percent acetic acid at 80 °C for 16 hours) in order to examine phase composition using X-ray diffraction analysis and ΔE, ΔL and ΔC color parameters through spectrophotometry. The translucency parameter (TP) was calculated using parameters L*, a* and b* on a black and white surface. Results Regardless of the surface treatment, aging protocols did not cause a tetragonal-to-monoclinic phase transformation, although hydrothermal degradation in the autoclave transformed the hybrid tetragonal-cubic structure of all specimens to a tetragonal one. All polished and glazed specimens during chemical degradation demonstrated a significant color change ΔE. Lightness ΔL significantly changed in polished specimens aged in the autoclave. In all specimens, ΔC underwent a change manifested through statistically insignificant yellowing. None of the aging protocols altered the translucency of specimens. Conclusions Aging, regardless of the final surface treatment, did not manifest a monoclinic phase in the specimens. A tetragonal-cubic microstructure dominates. Unlike polishing, glazing the surface of translucent zirconia ceramics contributed to minor changes in color, lightness and chromaticity. The translucency of translucent zirconia ceramics remains stable regardless of aging and surface treatment.
Collapse
Affiliation(s)
- Korina Mešić
- DMD; Polyvalent Dental Office, 10 000 Zagreb, Croatia
| | - Igor Majnarić
- Associate Professor; Faculty of Graphic Arts, 10 000 Zagreb, Croatia
| | - Ketij Mehulić
- Professor; Dental Clinic, University Hospital Centre Zagreb, 10 000 Zagreb, Croatia
| |
Collapse
|
43
|
Sodeyama MK, Ikeda H, Nagamatsu Y, Masaki C, Hosokawa R, Shimizu H. Printable PICN Composite Mechanically Compatible with Human Teeth. J Dent Res 2021; 100:1475-1481. [PMID: 33978514 DOI: 10.1177/00220345211012930] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Polymer-infiltrated ceramic network (PICN) composites are mechanically compatible with human enamel, and are therefore promising dental restorative materials. Fabrication technology for PICN composites used in tooth restorative material has been established through computer-aided design/computer-aided manufacturing (CAD/CAM) milling, however, to date, has not been successfully developed using 3-dimensional (3D) printing. This study aimed to develop a 3D-printable PICN composite as a restorative material. The PICN composite was fabricated using a specific method based on 3D printing. A 3D-printable precursor slurry containing a high concentration of silica nanoparticles was produced and 3D-printed using stereolithography (SLA). The 3D-printed object was sintered to obtain a nano-porous object, and subsequently infiltrated and polymerized with resin monomer. Three different fabrication condition combinations were used to produce the 3D-printed PICN composites, which were characterized based on microstructure, mechanical properties, inorganic content, physicochemical properties, and overall shrinkage. The 3D-printed PICN composites were also compared to 2 commercially available CAD/CAM composite blocks, namely a PICN composite and a dispersed-filler composite. The 3D-printed PICN composites exhibited a nano-sized dual-network structure comprising a silica skeleton with infiltrated resin. The 3D-printed PICN composite exhibited a similar Vickers hardness to enamel, and a similar elastic modulus to dentin. The 3D-printed PICN composite exhibited comparable flexural strength (>100 MPa) to the CAD/CAM block, and acceptable water sorption and solubility for practical use. Further, the 3D-printed model-crown underwent isotropic shrinkage during sintering without fatal deformation. Overall, the potential of this 3D-printable PICN composite as a restorative material with similar mechanical properties to human teeth was successfully demonstrated.
Collapse
Affiliation(s)
- M K Sodeyama
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, Fukuoka, Japan.,Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, Fukuoka, Japan
| | - H Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, Fukuoka, Japan
| | - Y Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, Fukuoka, Japan
| | - C Masaki
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, Fukuoka, Japan
| | - R Hosokawa
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, Fukuoka, Japan
| | - H Shimizu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, Fukuoka, Japan
| |
Collapse
|
44
|
Kilinc H, Sanal FA. Effect of sintering and aging processes on the mechanical and optical properties of translucent zirconia. J Prosthet Dent 2021; 126:129.e1-129.e7. [PMID: 33965239 DOI: 10.1016/j.prosdent.2021.03.024] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 03/24/2021] [Accepted: 03/24/2021] [Indexed: 02/04/2023]
Abstract
STATEMENT OF PROBLEM Sintering holding times and aging conditions may affect the optical, mechanical, and structural properties of polychromatic multitranslucent zirconia. However, a consensus on the ideal sintering condition for this material is lacking. PURPOSE The purpose of this in vitro study was to investigate the effect of different sintering holding and autoclave aging times on the flexural strength (FS), grain size, and translucency parameter (TP00) of a translucent zirconia. MATERIAL AND METHODS Sixty bar-shaped and 60 rectangular-shaped specimens were prepared from computer-aided design and computer-aided manufacturing (CAD-CAM) zirconia blocks and split into 2 groups to be sintered at 1550 °C for different holding times (regular: 2 hours, prolonged: 5 hours). The specimens were then divided into 3 subgroups and subjected to aging processes (control, aging for 60 minutes, aging for 120 minutes). FS values were obtained by using a 3-point bend test and Weibull analysis was conducted. Grain size evaluations were performed by using scanning electron microscope (SEM) observations. TP00 was measured with a spectrophotometer. Statistical evaluation included the Kolmogorov-Smirnov, 2-way ANOVA, and Tukey HSD tests (α=.05). RESULTS The sintering procedure, aging, and their interaction significantly influenced the TP00 (P<.05). FS values and grain sizes were affected by aging only (P<.001). Both aging times resulted in reduced FS and increased grain sizes. Prolonged sintering in combination with 120 minutes of aging negatively affect the TP00 scores (P<.05). CONCLUSIONS FS values were similar under regular and prolonged sintering. Prolonged sintering led to a decrease in translucency after 120 minutes of aging. Steam autoclave aging can affect the optical and mechanical properties of translucent zirconia.
Collapse
Affiliation(s)
- Hamiyet Kilinc
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Bolu Abant Izzet Baysal University, Bolu, Turkey.
| | - Fatma A Sanal
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Bolu Abant Izzet Baysal University, Bolu, Turkey
| |
Collapse
|
45
|
Luz JN, Kaizer MDR, Ramos NDC, Anami LC, Thompson VP, Saavedra GDSFA, Zhang Y. Novel speed sintered zirconia by microwave technology. Dent Mater 2021; 37:875-881. [PMID: 33715863 PMCID: PMC11283878 DOI: 10.1016/j.dental.2021.02.026] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 02/18/2021] [Accepted: 02/24/2021] [Indexed: 01/21/2023]
Abstract
OBJECTIVE Continuous efforts have been made to hasten the zirconia densification process without compromising properties. This study evaluated the long-term structural durability of microwave speed-sintered zirconia (MWZ) relative to a conventionally sintered zirconia (CZ). METHODS As-machined dental 3Y-TZP discs (Ø12 × 1.2 mm) were speed sintered at 1450 °C for 15 min using an industrial microwave oven, while conventional sintering was conducted in a standard dental furnace at 1530 °C for 2 h. Both were followed by natural cooling. The total sintering time was 105 min for MWZ and 600 min for CZ. Groups were compared regarding density, grain size, phase composition, and fracture resistance. Structural durability was investigated employing two fatigue protocols, step-stress and dynamic fatigue. RESULTS Compared to CZ, MWZ exhibited a slightly lower density (MWZ = 5.98 g/cm3, CZ = 6.03 g/cm3), but significantly smaller grain sizes (MWZ = 0.53 ± 0.09 μm, CZ = 0.89 ± 0.10 μm), lower cubic-zirconia contents (MWZ = 15.3%, CZ = 22.7%), and poorer translucency properties (TP) (MWZ = 13 ± 1, CZ = 29 ± 0.8). However, the two materials showed similar flexural strength (MWZ = 978 ± 112 MPa, CZ = 1044 ± 161 MPa). Additionally, step-stress testing failed to capture the fatigue effect in 3Y-TZP, whereas dynamic fatigue revealed structural degradation due to moisture-assisted slow-crack-growth (SCG). Finally, MWZ possessed a slightly higher Weibull modulus (MWZ = 7.9, CZ = 6.7) but similar resistance to SCG (MWZ = 27.5, CZ = 24.1) relative to CZ. SIGNIFICANCE Dental 3Y-TZP with similar structural durability can be fabricated six-times faster by microwave than conventional sintering.
Collapse
Affiliation(s)
- Julio Nogueira Luz
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of Sao Jose dos Campos, Sao Paulo State University (UNESP), 777 Eng. Francisco Jose Longo Avenue, Sao Jose dos Campos, SP 12245-000, Brazil
| | | | - Nathália de Carvalho Ramos
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of Sao Jose dos Campos, Sao Paulo State University (UNESP), 777 Eng. Francisco Jose Longo Avenue, Sao Jose dos Campos, SP 12245-000, Brazil
| | - Lilian Costa Anami
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of Sao Jose dos Campos, Sao Paulo State University (UNESP), 777 Eng. Francisco Jose Longo Avenue, Sao Jose dos Campos, SP 12245-000, Brazil
| | - Van P Thompson
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 1st Ave., New York, NY 10010, United States
| | - Guilherme de Siqueira Ferreira Anzaloni Saavedra
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of Sao Jose dos Campos, Sao Paulo State University (UNESP), 777 Eng. Francisco Jose Longo Avenue, Sao Jose dos Campos, SP 12245-000, Brazil.
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, University of Pennsylvanian, School of Dental Medicine, 240 S. 40th St., Philadelphia, PA 19104, United States.
| |
Collapse
|
46
|
Fathy SM, Al-Zordk W, E Grawish M, V Swain M. Flexural strength and translucency characterization of aesthetic monolithic zirconia and relevance to clinical indications: A systematic review. Dent Mater 2021; 37:711-730. [PMID: 33581910 DOI: 10.1016/j.dental.2021.01.022] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 11/15/2020] [Accepted: 01/20/2021] [Indexed: 02/04/2023]
Affiliation(s)
- Salma M Fathy
- Dental Biomaterials Department, Faculty of Oral and Dental Medicine, Zagazig University, Zagazig, Egypt.
| | - Walid Al-Zordk
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Mohammed E Grawish
- Oral Biology Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Micheal V Swain
- Discipline of Biomaterials, Faculty of Dentistry, University of Sydney, Australia
| |
Collapse
|
47
|
Nakamura T, Okamura S, Nishida H, Kawano A, Tamiya S, Wakabayashi K, Sekino T. Fluorescence and physical properties of thulium and erbium co-doped dental zirconia. Dent Mater J 2021; 40:1080-1085. [PMID: 33775986 DOI: 10.4012/dmj.2020-387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The fluorescence and physical properties of thulium and erbium co-doped dental zirconia were investigated. The high-translucency yttria-stabilized dental zirconia specimens co-doped with Tm2O3 powder 0.8 wt% and Er2O3 powder at proportions from 0.1 to 0.8 wt% were used. The specimens co-doped with Tm2O3 powder 0.8 wt% and Er2O3 from 0.3 to 0.5 wt% exhibited the fluorescence similar to that of natural tooth. All the specimens had a tetragonal peak and no major change in the Vickers hardness, fracture toughness and bending strength on addition of Tm2O3 and Er2O3. These results suggest that the method of co-doping trace amounts of Tm2O3 and Er2O3 into high-translucency dental zirconia powder can effectively improve the esthetics of zirconia monolithic fixed dental prothesis.
Collapse
Affiliation(s)
- Takashi Nakamura
- Department of Oral Health Sciences, Otemae College.,Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| | - Shinya Okamura
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| | - Hisataka Nishida
- Institute of Scientific and Industrial Research, Osaka University
| | - Akiyo Kawano
- Department of Oral Health Sciences, Otemae College
| | - Shingo Tamiya
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| | | | - Tohru Sekino
- Institute of Scientific and Industrial Research, Osaka University
| |
Collapse
|
48
|
Ramos GF, Ramos NC, Alves LMM, Kaizer MR, Borges ALS, Campos TMB, Melo RM. Failure probability and stress distribution of milled porcelain-zirconia crowns with bioinspired/traditional design and graded interface. J Mech Behav Biomed Mater 2021; 119:104438. [PMID: 33798936 DOI: 10.1016/j.jmbbm.2021.104438] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 09/14/2020] [Accepted: 02/26/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVE To evaluate the failure probability and stress distribution of traditional and bioinspired porcelain-zirconia milled crowns, with and without silica infiltration (graded zirconia). METHODS Traditional crown design had a zirconia infrastructure veneered with porcelain; Bioinspired, had a porcelain infrastructure with translucent-zirconia veneer; Graded and Graded Bioinspired crowns had their zirconia layer infiltrated by silica (n = 25). The cameo surface of each crown (porcelain or zirconia) was glazed. The restoration layers were fused by a vitreous connector and the crowns were adhesively cemented to dies. The specimens were then mechanically cycled in a sliding machine using 100 N load at 4 Hz. The specimens were tested until 2 × 106 cycles, and every 0.5 × 106 cycles the crowns were evaluated under stereomicroscopy for the presence of failures. The stress distribution was inspected with Finite Element Analyses. RESULTS The predominant failure modes for the Traditional and Graded crowns were delamination and cracking, respectively. The Weibull parameters beta and eta were, respectively: Traditional 1.30 and 2.3 × 106 cycles, and Graded 1.95 and 2.3 × 106 cycles. Thus, the Traditional and Graded crowns presented greater susceptibility to failure due to fatigue, while the Bioinspired and Graded Bioinspired crowns showed no fatigue effect using 100N load, showing beta = 1 and eta of approximately 17 × 106 cycles. Also, through finite element analyses, it was verified that the Bioinspired and Graded Bioinspired crowns presented the best stress distribution on both crowns and dental structures. SIGNIFICANCE Bioinspired and Graded Bioinspired crowns had the lowest failure probability and better stress distribution and may be considered robust long lasting restorations.
Collapse
Affiliation(s)
- G F Ramos
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| | - N C Ramos
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil; College of Dentistry, Sao Francisco University (USF), 218 Sao Francisco de Assis Avenue, 12916-900, Bragança Paulista, SP, Brazil.
| | - L M M Alves
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| | - M R Kaizer
- College of Dentistry, Positivo University (UP), 5300 Prof. Pedro Viriato Parigot de Souza Street, 81280-330, Curitiba, PR, Brazil.
| | - A L S Borges
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| | - T M B Campos
- Physics Department, Technological Institute of Aeronatics (ITA), 50 Praça Marechal Eduardo Gomes, 12228-900, São José Dos Campos, SP, Brazil.
| | - R M Melo
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| |
Collapse
|
49
|
Mešić K, Majnarić I, Obhođaš J, Baršić G, Mehulić K. The Effect of Aging on Composition and Surface of Translucent Zirconia Ceramic. Acta Stomatol Croat 2020; 54:339-352. [PMID: 33642598 PMCID: PMC7871433 DOI: 10.15644/asc54/4/1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Objectives To examine the effect of two aging protocols on the chemical and phase composition as well as the surface state of monolithic translucent zirconia ceramics. Material and Methods Translucent zirconia ceramics KATANA-Zirconia STML with different surface treatments (no treatment, K1, K2; glazed, G1-G8; polished, P1-P8) underwent testing in order to examine how the two aging protocols (three-hour hydrothermal degradation in an autoclave at 134 °C and 2 bars: G1-G4, P1-P4, and sixteen-hour chemical degradation in four-percent acetic acid at 80 °C (ISO 6872): G5-G8, P5-P8) affect chemical composition, particularly the share of stabilizing yttrium oxide (Energy Dispersive X-Ray Fluorescence – EDXRF), phase composition (X-ray diffraction – XRD) and surface state in terms of roughness and gloss. Results Aging protocols did not affect the tested chemical composition stability of specimens and a high share of stabilizing yttrium-oxide (≥10% of total content), which correlates with the absence of monoclinic phase. A decrease in gloss on all specimens is statistically significant. Chemical degradation substantially increased the surface roughness of tested specimens. Conclusions Translucent monolithic zirconia demonstrated a stable chemical composition and resistance to tetragonal-to-monoclinic transformation. Surface gloss was significantly reduced, especially in polished specimens. Contrary to glazed specimens, the tested polished specimens manifested an increase in surface roughness. Glazing the surface of translucent monolithic zirconia produces better esthetic, tribological and hygienic effects than polishing.
Collapse
Affiliation(s)
- Korina Mešić
- Polyvalent Dental Office, 10 000 Zagreb, Croatia
| | | | | | - Gorana Baršić
- Faculty of Mechanical Engineering and Naval Architecture, 10 000 Zagreb, Croatia
| | - Ketij Mehulić
- School of Dental Medicine University of Zagreb & Dental Clinic, University Hospital Centre Zagreb, 10 000 Zagreb, Croatia
| |
Collapse
|
50
|
Laser-assisted production of HAp-coated zirconia structured surfaces for biomedical applications. J Mech Behav Biomed Mater 2020; 112:104049. [DOI: 10.1016/j.jmbbm.2020.104049] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Revised: 08/15/2020] [Accepted: 08/19/2020] [Indexed: 12/18/2022]
|