1
|
Adeoye JB, Tan YH, Lau SY, Tan YY, Chiong T, Mubarak NM, Khalid M. Advanced oxidation and biological integrated processes for pharmaceutical wastewater treatment: A review. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 353:120170. [PMID: 38308991 DOI: 10.1016/j.jenvman.2024.120170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Revised: 01/02/2024] [Accepted: 01/20/2024] [Indexed: 02/05/2024]
Abstract
The stress of pharmaceutical and personal care products (PPCPs) discharging to water bodies and the environment due to increased industrialization has reduced the availability of clean water. This poses a potential health hazard to animals and human life because water contamination is a great issue to the climate, plants, humans, and aquatic habitats. Pharmaceutical compounds are quantified in concentrations ranging from ng/Lto μg/L in aquatic environments worldwide. According to (Alsubih et al., 2022), the concentrations of carbamazepine, sulfamethoxazole, Lutvastatin, ciprofloxacin, and lorazepam were 616-906 ng/L, 16,532-21635 ng/L, 694-2068 ng/L, 734-1178 ng/L, and 2742-3775 ng/L respectively. Protecting and preserving our environment must be well-driven by all sectors to sustain development. Various methods have been utilized to eliminate the emerging pollutants, such as adsorption and biological and advanced oxidation processes. These methods have their benefits and drawbacks in the removal of pharmaceuticals. Successful wastewater treatment can save the water bodies; integrating green initiatives into the main purposes of actor firms, combined with continually periodic awareness of the current and potential implications of environmental/water pollution, will play a major role in water conservation. This article reviews key publications on the adsorption, biological, and advanced oxidation processes used to remove pharmaceutical products from the aquatic environment. It also sheds light on the pharmaceutical adsorption capability of adsorption, biological and advanced oxidation methods, and their efficacy in pharmaceutical concentration removal. A research gap has been identified for researchers to explore in order to eliminate the problem associated with pharmaceutical wastes. Therefore, future study should focus on combining advanced oxidation and adsorption processes for an excellent way to eliminate pharmaceutical products, even at low concentrations. Biological processes should focus on ideal circumstances and microbial processes that enable the simultaneous removal of pharmaceutical compounds and the effects of diverse environments on removal efficiency.
Collapse
Affiliation(s)
- John Busayo Adeoye
- Department of Chemical and Energy Engineering, Faculty of Engineering and Science, Curtin University Malaysia, CDT 250, 98009, Miri, Sarawak, Malaysia.
| | - Yie Hua Tan
- Petroleum and Chemical Engineering, Faculty of Engineering, Universiti Teknologi Brunei, Bandar Seri Begawan, BE1410, Brunei Darussalam.
| | - Sie Yon Lau
- Department of Chemical and Energy Engineering, Faculty of Engineering and Science, Curtin University Malaysia, CDT 250, 98009, Miri, Sarawak, Malaysia.
| | - Yee Yong Tan
- Department of Civil and Construction Engineering, Faculty of Engineering and Science, Curtin University Malaysia, CDT 250, Sarawak, Miri, 98009, Malaysia
| | - Tung Chiong
- Department of Chemical and Energy Engineering, Faculty of Engineering and Science, Curtin University Malaysia, CDT 250, 98009, Miri, Sarawak, Malaysia
| | - Nabisab Mujawar Mubarak
- Petroleum and Chemical Engineering, Faculty of Engineering, Universiti Teknologi Brunei, Bandar Seri Begawan, BE1410, Brunei Darussalam; Department of Biosciences, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Chennai, India
| | - Mohammad Khalid
- Sunway Centre for Electrochemical Energy and Sustainable Technology (SCEEST), School of Engineering and Technology, Sunway University, No. 5 Jalan Universiti, Bandar Sunway, 47500 Petaling Jaya, Selangor, Malaysia; Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, Karnataka, India; Centre of Research Impact and Outcome, Chitkara University Institute of Engineering and Technology, Chitkara University, Punjab 140401, India
| |
Collapse
|
2
|
Taweetanawanit P, Therdkiattikul N, Sonsuphab K, Sucharitpwatskul S, Suriyawanakul J, Radpukdee T, Ratpukdi T, Siripattanakul-Ratpukdi S. Triclocarban-contaminated wastewater treatment by innovative hybrid moving entrapped bead activated sludge reactor (HyMER): Continuous performance and computational dynamic simulation analysis. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 879:163037. [PMID: 37001270 DOI: 10.1016/j.scitotenv.2023.163037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Revised: 03/20/2023] [Accepted: 03/20/2023] [Indexed: 05/17/2023]
Abstract
Triclocarban (TCC) has been used in consumer products and is a widespread contaminant in municipal wastewater treatment systems that ultimately accumulates in natural receiving water and soil. This work aims to apply an innovative hybrid moving entrapped bead activated sludge reactor (named "HyMER") that integrates entrapped TCC-degrading microbes and freely suspended activated sludge to treat TCC-contaminated wastewater. A previously isolated TCC-degrading bacterium (Pseudomonas fluorescens strain MC46, called MC46) and barium alginate entrapment were applied. The synthetic TCC-contaminated wastewater treatment (with TCC concentration of 10 mg/L) was performed using 20-cycle fed-batch reactor operation with feeding times of 12 and 24 h and cycle times of 13 and 25 h. The results indicated that the HyMER effectively reduced chemical oxygen demand by up to 80 and 95 % and TCC by up to 53 and 83 %, respectively, with feeding times of 12 and 24 h. Three TCC degradation intermediate products were found-3,4-dichloroaniline, 4-chloroaniline, and aniline. Scanning electron microscopic analysis revealed shorter cells and bacterial appendage development as cell adaptations against TCC and its intermediates. The live/dead assay indicated high survival of entrapped MC46 in toxic conditions, with up to 84 % viable cells. Based on computational fluid dynamic analysis, no entrapped cell agglomeration showed in the reactor, indicating the potential application of HyMER for real wastewater treatment. These results exhibit the feasibility of HyMER and its applicability for future toxic wastewater treatment.
Collapse
Affiliation(s)
- Pongsatorn Taweetanawanit
- Department of Environmental Engineering, Faculty of Engineering and Research Center for Environmental and Hazardous Substance Management, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Nakharin Therdkiattikul
- Department of Environmental Engineering, Faculty of Engineering and Research Center for Environmental and Hazardous Substance Management, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Khuanchanok Sonsuphab
- Department of Environmental Engineering, Faculty of Engineering and Research Center for Environmental and Hazardous Substance Management, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Sedthawatt Sucharitpwatskul
- National Metal and Materials Technology Center (MTEC), National Science and Technology Development Agency (NSTDA), Pathum Thani 12120, Thailand
| | - Jarupol Suriyawanakul
- Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Thana Radpukdee
- Department of Industrial Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Thunyalux Ratpukdi
- Department of Environmental Engineering, Faculty of Engineering and Research Center for Environmental and Hazardous Substance Management, Khon Kaen University, Khon Kaen 40002, Thailand; Center of Excellence on Hazardous Substance Management (HSM), Bangkok 10330, Thailand
| | - Sumana Siripattanakul-Ratpukdi
- Department of Environmental Engineering, Faculty of Engineering and Research Center for Environmental and Hazardous Substance Management, Khon Kaen University, Khon Kaen 40002, Thailand; Center of Excellence on Hazardous Substance Management (HSM), Bangkok 10330, Thailand.
| |
Collapse
|
3
|
Shanmuganathan R, Sibtain Kadri M, Mathimani T, Hoang Le Q, Pugazhendhi A. Recent innovations and challenges in the eradication of emerging contaminants from aquatic systems. CHEMOSPHERE 2023; 332:138812. [PMID: 37127197 DOI: 10.1016/j.chemosphere.2023.138812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 04/11/2023] [Accepted: 04/28/2023] [Indexed: 05/03/2023]
Abstract
Presence of emerging pollutants (EPs), aka Micropollutants (MPs) in the freshwater environments is a severe threat to the environment and human beings. They include pharmaceuticals, insecticides, industrial chemicals, natural hormones, and personal care items and the pollutants are mostly present in wastewater generated from urbanization and increased industrial growth. Even concentrations as low as ngL-1 or mgL-1 have proven ecologically lethal to aquatic biota. For several years, the biodegradation of various Micropollutants (MPs) in aquatic ecosystems has been a significant area of research worldwide, with many chemical compounds being discovered in various water bodies. As aquatic biota spends most of their formative phases in polluted water, the impacts on aquatic biota are obvious, indicating that the environmental danger is substantial. In contrast, the impact of these contaminants on aquatic creatures and freshwater consumption is more subtle and manifests directly when disrupting the endocrine system. Research and development activities are expected to enable the development of ecologically sustainable, cost-effective, and efficient treatments for practical systems in the near future. Therefore, this review aims to understand recent emerging pollutants discovered and the available treatment technologies and suggest an innovative and cost-effective method to treat these EPs, which is sustainable and follows the circular bioeconomy.
Collapse
Affiliation(s)
- Rajasree Shanmuganathan
- School of Medicine and Pharmacy, Duy Tan University, Da Nang, Viet Nam; Institute of Research and Development, Duy Tan University, Da Nang, Viet Nam
| | - Mohammad Sibtain Kadri
- Department of Marine Biotechnology and Resources, National Sun Yat-Sen University, Kaohsiung City, 804201, Taiwan
| | - Thangavel Mathimani
- Department of Energy and Environment, National Institute of Technology Tiruchirappalli, Tamil Nadu, India
| | - Quynh Hoang Le
- School of Medicine and Pharmacy, Duy Tan University, Da Nang, Viet Nam; Institute of Research and Development, Duy Tan University, Da Nang, Viet Nam
| | - Arivalagan Pugazhendhi
- Emerging Materials for Energy and Environmental Applications Research Group, School of Engineering and Technology, Van Lang University, Ho Chi Minh City, Viet Nam.
| |
Collapse
|
4
|
Sengar A, Vijayanandan A. Fate and removal of iodinated X-ray contrast media in membrane bioreactor: Microbial dynamics and effects of different operational parameters. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 869:161827. [PMID: 36708825 DOI: 10.1016/j.scitotenv.2023.161827] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 01/18/2023] [Accepted: 01/21/2023] [Indexed: 06/18/2023]
Abstract
Iodinated X-ray contrast media (ICM) are mainly used in medical sector, and their presence in environmental waters is a cause of concern as they are capable of forming highly toxic iodinated disinfection byproducts. In the present study, the removal mechanisms of the three ICM- iohexol, iopromide, and iopamidol were elucidated in a lab-scale aerobic membrane bioreactor (MBR). At steady-state operation (solids retention time (SRT)- 70 days, organic loading rate (OLR)- 0.80 KgCOD/m3-day, nitrogen loading rate (NLR)- 0.08 KgNH4-N/m3-day, hydraulic retention time (HRT)- 12 h), the average removal of iohexol and iopromide was found to be 34.9 and 45.2 %, respectively, whereas iopamidol proved to be highly recalcitrant in aerobic conditions of the MBR (removal <10 % in all phases of the MBR operation). Further, through batch kinetic studies and mass balance analysis, it was observed that ICM were primarily biotransformed in the MBR system and biosorption (Kd < 10 L/Kg) was negligible. The biodegradation rate coefficient values (Kbiol) of the ICM were found to be <0.65 L/g-d which indicate that biotransformation rate of ICM was slow. Increased OLR (1.60 KgCOD/m3-day) and reduced SRT (20 days) were found to negatively affect the removal of the ICM. Further, the removal of ICM was found to depend on its initial concentration, and the increment in the ammonium loading (0.16 KgNH4-N/m3-day) did not favor its removal. The dosing of ICM altered the microbial dynamics of the mixed liquor and reduced the microbial diversity and richness. Bdellovibrio, Zoogloea, and bacteria belonging to TM7-3 class, Cryomorphaceae and Hyphomonadaceae families may contribute in ICM biotransformation.
Collapse
Affiliation(s)
- Ashish Sengar
- Department of Civil Engineering, Indian Institute of Technology Delhi (IIT Delhi), New Delhi 110016, India
| | - Arya Vijayanandan
- Department of Civil Engineering, Indian Institute of Technology Delhi (IIT Delhi), New Delhi 110016, India.
| |
Collapse
|
5
|
Appraising efficacy of existing and advanced technologies for the remediation of beta-blockers from wastewater: A review. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:25427-25451. [PMID: 35094282 DOI: 10.1007/s11356-021-18287-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 12/19/2021] [Indexed: 02/08/2023]
Abstract
The discharge of emerging pollutants, such as beta-blockers (BB), has been recognized as one of the major threats to the environment due to the ecotoxicity associated with these emerging pollutants. The BB are prescribed to treat high blood pressure and cardiovascular diseases; however, even at lower concentration, these pollutants can pose eco-toxic impacts towards aquatic organisms. Additionally, owing to their recalcitrant nature, BB are not effectively removed through conventional technologies, such as activated sludge process, trickling filter and moving bed bioreactor; thus, it is essential to understand the degradation mechanism of BB in established as well as embryonic technologies, like adsorption, electro-oxidation, Fenton process, ultraviolet-based advance oxidation process, ozonation, membrane systems, wetlands and algal treatment. In this regard, this review articulates the recalcitrant nature of BB and their associated removal technologies. Moreover, the major advantages and limitations of these BB removal technologies along with the recent advancements with regard to the application of innovative materials and strategies have also been elucidated. Therefore, the present review intends to aid the researchers in improving the BB removal efficiency of these technologies, thus alleviating the problem of the release of BB into the environment.
Collapse
|
6
|
Wang G, Tang K, Hambly AC, Zhang Y, Andersen HR. Sustainable and Reagentless Fenton Treatment of Complex Wastewater. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:626-634. [PMID: 36511650 DOI: 10.1021/acs.est.2c06702] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Conventional Fenton treatment is fundamentally impractical for large-scale applications, as the consumption of Fe(II), H2O2, and pH regulators and the accumulation of iron hydroxide sludge are very costly. This paper describes a new method for Fenton treatment of complex wastewater without additional dosing of Fe(II) and H2O2, without iron-sludge accumulation, and with less consumption of pH regulators, using a novel bioelectrode system. Our new system includes a novel three-chamber microbial electrolysis unit and Fenton reaction unit, where Fenton reagents are generated by biotic and abiotic cathodes, while the bioanode simultaneously degrades biodegradable organics from the wastewater. The system's self-alkalinity buffering also waives the need for pH regulators. Dissolved organic carbon and 22 specific recalcitrant organics were removed by 99% and between 78 and 100%, respectively. The bioelectrode system generated 13 ± 3 mg/L dissolved Fe(II) and 5 ± 0.4 mg/L H2O2 for the Fenton reaction unit. The closed iron cycle avoided iron loss and iron sludge accumulation during operation. The pH regulator dosage and operating costs were just 9.7 and 1.4%, respectively, of what is required by classic Fenton. The low operating cost and reduction in chemical usage make it an efficient, sustainable alternative to the conventional treatment processes currently used for complex wastewater.
Collapse
Affiliation(s)
- Guan Wang
- Department of Environmental and Resource Engineering, Technical University of Denmark, DK-2800Lyngby, Denmark
| | - Kai Tang
- Department of Environmental and Resource Engineering, Technical University of Denmark, DK-2800Lyngby, Denmark
| | - Adam C Hambly
- Department of Environmental and Resource Engineering, Technical University of Denmark, DK-2800Lyngby, Denmark
| | - Yifeng Zhang
- Department of Environmental and Resource Engineering, Technical University of Denmark, DK-2800Lyngby, Denmark
| | - Henrik Rasmus Andersen
- Department of Environmental and Resource Engineering, Technical University of Denmark, DK-2800Lyngby, Denmark
| |
Collapse
|
7
|
Zulkifli M, Abu Hasan H, Sheikh Abdullah SR, Muhamad MH. A review of ammonia removal using a biofilm-based reactor and its challenges. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 315:115162. [PMID: 35561462 DOI: 10.1016/j.jenvman.2022.115162] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Revised: 04/16/2022] [Accepted: 04/22/2022] [Indexed: 06/15/2023]
Abstract
Extensive growth of industries leads to uncontrolled ammonia releases to environment. This can result in significant degradation of the aquatic ecology as well as significant health concerns for humans. Knowing the mechanism of ammonia elimination is the simplest approach to comprehending it. Ammonia has been commonly converted to less hazardous substances either in the form of nitrate or nitrogen gas. Ammonia has been converted into nitrite by ammonia-oxidizing bacteria and further reduced to nitrate by nitrite-oxidizing bacteria in aerobic conditions. Denitrification takes place in an anoxic phase and nitrate is converted into nitrogen gas. It is challenging to remove ammonia by employing technologies that do not incur particularly high costs. Thus, this review paper is focused on biofilm reactors that utilize the nitrification process. Many research publications and patents on biofilm wastewater treatment have been published. However, only a tiny percentage of these projects are for full-scale applications, and the majority of the work was completed within the last few decades. The physicochemical approaches such as ammonia adsorption, coagulation-flocculation, and membrane separation, as well as conventional biological treatments including activated sludge, microalgae, and bacteria biofilm, are briefly addressed in this review paper. The effectiveness of biofilm reactors in removing ammonia was compared, and the microbes that effectively remove ammonia were thoroughly discussed. Overall, biofilm reactors can remove up to 99.7% ammonia from streams with a concentration in range of 16-900 mg/L. As many challenges were identified for ammonia removal using biofilm at a commercial scale, this study offers future perspectives on how to address the most pressing biofilm issues. This review may also improve our understanding of biofilm technologies for the removal of ammonia as well as polishing unit in wastewater treatment plants for the water reuse and recycling, supporting the circular economy concept.
Collapse
Affiliation(s)
- Maryam Zulkifli
- Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia.
| | - Hassimi Abu Hasan
- Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia; Research Centre for Sustainable Process Technology (CESPRO), Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia.
| | - Siti Rozaimah Sheikh Abdullah
- Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia; Research Centre for Sustainable Process Technology (CESPRO), Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia.
| | - Mohd Hafizuddin Muhamad
- Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia.
| |
Collapse
|
8
|
Li J, Zheng L, Ye C, Zhou Z, Ni B, Zhang X, Liu H. Unveiling organic loading shock-resistant mechanism in a pilot-scale moving bed biofilm reactor-assisted dual-anaerobic-anoxic/oxic system for effective municipal wastewater treatment. BIORESOURCE TECHNOLOGY 2022; 347:126339. [PMID: 34775052 DOI: 10.1016/j.biortech.2021.126339] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 11/07/2021] [Accepted: 11/09/2021] [Indexed: 06/13/2023]
Abstract
Microbial biomass and activity are frequently subjected to organic loading shock (OLS) from decentralized municipal wastewater. A hybrid moving bed biofilm reactor-assisted dual-anaerobic-anoxic/oxic system (D-A2MBBR) was established by integrating dual-anaerobic-anoxic/oxic with moving bed biofilm reactor to resist OLS for stable nutrients removal. The D-A2MBBR achieved 91.57% of chemical oxygen demand, 93.33% of ammonia-nitrogen, 80.20% of total nitrogen and 92.68% of total phosphorus removal, respectively, under the fluctuation of organic loading rate from 417.9 to 812.0 g COD m-3 d-1. The 16S rRNA gene sequencing revealed that Gemmobacter (7.28%) was identified as dominating anoxic denitrifying genus in oxic chamber, confirming the coexistence of aerobic and anaerobic/anoxic micro-environments. This circumstance boosted simultaneous nitrification-denitrification and phosphorus removal and the microbial community evolution inside the multilayer biocarrier-attached biofilms. In general, the D-A2MBBR was able to provide unique, cooperative and robust bacterial consortia to form a buffer against OLS, and ensuring effluent stability.
Collapse
Affiliation(s)
- Jia Li
- Key Laboratory of Hydraulic and Waterway Engineering of the Ministry of Education, School of River and Ocean Engineering, Chongqing Jiaotong University, Chongqing 400074, PR China; Key Laboratory of Reservoir Aquatic Environment, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, PR China; Research Center for Pollution Control and Ecological Restoration, Yuxi Normal University, Yuxi 653100, Yunnan, PR China
| | - Lei Zheng
- Key Laboratory of Reservoir Aquatic Environment, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, PR China
| | - Changbing Ye
- Research Center for Pollution Control and Ecological Restoration, Yuxi Normal University, Yuxi 653100, Yunnan, PR China
| | - Zhiming Zhou
- Research Center for Pollution Control and Ecological Restoration, Yuxi Normal University, Yuxi 653100, Yunnan, PR China
| | - Baosen Ni
- Research Center for Pollution Control and Ecological Restoration, Yuxi Normal University, Yuxi 653100, Yunnan, PR China
| | - Xiaomei Zhang
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, Shandong, PR China
| | - Hong Liu
- Key Laboratory of Reservoir Aquatic Environment, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, PR China.
| |
Collapse
|
9
|
Mahto KU, Das S. Bacterial biofilm and extracellular polymeric substances in the moving bed biofilm reactor for wastewater treatment: A review. BIORESOURCE TECHNOLOGY 2022; 345:126476. [PMID: 34864174 DOI: 10.1016/j.biortech.2021.126476] [Citation(s) in RCA: 31] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 11/27/2021] [Accepted: 11/28/2021] [Indexed: 06/13/2023]
Abstract
Among the several biofilm-based bioreactors, moving bed biofilm reactors (MBBR) have been extensively used for wastewater treatment due to low operational costs, technical feasibility, and stability. Biofilm forming strains, e.g., Stenotrophomonas maltophila DQ01, achieved 94.21% simultaneous nitrification and denitrification (SND) and 94.43% removal of total nitrogen (TN) at a cycle time of 7 h, and a biofilm consortium consisting of Chryseobacteriumsp. andRhodobactersp. achieved 86.8% removal of total organic carbon (TOC) at hydraulic retention time (HRT) of 24 h using lab-scale MBBR. Modifications in the surface properties of the biocarrier materials achieved 99.5 ± 1.1% chemical oxygen demand (COD) and 93.6 ± 2.3% NH4+-N removal, significantly higher than the conventional commercial carrier. This review article summarizes the application of MBBR technology for wastewater treatment. The importance of bacterial biofilm and extracellular polymeric substances (EPS), anammox-n-DAMO coupled processes, and carrier surface modifications in MBBR technology have also been discussed.
Collapse
Affiliation(s)
- Kumari Uma Mahto
- Laboratory of Environmental Microbiology and Ecology (LEnME), Department of Life Science, National Institute of Technology, Rourkela 769 008, Odisha, India
| | - Surajit Das
- Laboratory of Environmental Microbiology and Ecology (LEnME), Department of Life Science, National Institute of Technology, Rourkela 769 008, Odisha, India.
| |
Collapse
|
10
|
Oh JE, Yoon Y, Zoh KD. Special issue: Current status and future prospects of micropollutants in water: Monitoring, removal, and risk. CHEMOSPHERE 2021; 263:128228. [PMID: 33297184 DOI: 10.1016/j.chemosphere.2020.128228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
|
11
|
Application of Hybrid Membrane Processes Coupling Separation and Biological or Chemical Reaction in Advanced Wastewater Treatment. MEMBRANES 2020; 10:membranes10100281. [PMID: 33066241 PMCID: PMC7602016 DOI: 10.3390/membranes10100281] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 09/29/2020] [Accepted: 10/09/2020] [Indexed: 02/01/2023]
Abstract
The rapid urbanization and water shortage impose an urgent need in improving sustainable water management without compromising the socioeconomic development all around the world. In this context, reclaimed wastewater has been recognized as a sustainable water management strategy since it represents an alternative water resource for non-potable or (indirect) potable use. The conventional wastewater remediation approaches for the removal of different emerging contaminants (pharmaceuticals, dyes, metal ions, etc.) are unable to remove/destroy them completely. Hybrid membrane processes (HMPs) are a powerful solution for removing emerging pollutants from wastewater. On this aspect, the present paper focused on HMPs obtained by the synergic coupling of biological and/or chemical reaction driven processes with membrane processes, giving a critical overview and particular emphasis on some case studies reported in the pertinent literature. By using these processes, a satisfactory quality of treated water can be achieved, permitting its sustainable reuse in the hydrologic cycle while minimizing environmental and economic impact.
Collapse
|