1
|
Elhoushy M, Zalam BA, Sayed A, Nabil E. Automated blood glucose regulation for nonlinear model of type-1 diabetic patient under uncertainties: GWOCS type-2 fuzzy approach. Biomed Eng Lett 2024; 14:127-151. [PMID: 38186949 PMCID: PMC10769999 DOI: 10.1007/s13534-023-00318-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 07/06/2023] [Accepted: 09/02/2023] [Indexed: 01/09/2024] Open
Abstract
Regulating blood glucose level (BGL) for type-1 diabetic patient (T1DP) accurately is very important issue, an uncontrolled BGL outside the standard safe range between 70 and 180 mg/dl results in dire consequences for health and can significantly increase the chance of death. So the purpose of this study is to design an optimized controller that infuses appropriate amounts of exogenous insulin into the blood stream of T1DP proportional to the amount of obtained glucose from food. The nonlinear extended Bergman minimal model is used to present glucose-insulin physiological system, an interval type-2 fuzzy logic controller (IT2FLC) is utilized to infuse the proper amount of exogenous insulin. Superiority of IT2FLC in minimizing the effect of uncertainties in the system depends primarily on the best choice of footprint of uncertainty (FOU) of IT2FLC. So a comparison includes four different optimization methods for tuning FOU including hybrid grey wolf optimizer-cuckoo search (GWOCS) and fuzzy logic controller (FLC) method is constructed to select the best controller approach. The effectiveness of the proposed controller was evaluated under six different scenarios of T1DP using Matlab/Simulink platform. A 24-h scenario close to real for 100 virtual T1DPs subjected to parametric uncertainty, uncertain meal disturbance and random initial condition showed that IT2FLC accurately regulate BGL for all T1DPs within the standard safe range. The results indicated that IT2FLC using GWOCS can prevent side effect of treatment with blood-sugar-lowering medication. Also stability analysis for the system indicated that the system operates within the stability region of nonlinear system.
Collapse
Affiliation(s)
- Mohanad Elhoushy
- Department of Industrial Electronics and Control Engineering, Faculty of Electronic Engineering, Menoufia University, Menouf, Egypt
| | - Belal A. Zalam
- Department of Industrial Electronics and Control Engineering, Faculty of Electronic Engineering, Menoufia University, Menouf, Egypt
| | - Amged Sayed
- Department of Industrial Electronics and Control Engineering, Faculty of Electronic Engineering, Menoufia University, Menouf, Egypt
- Department of Electrical Energy Engineering, College of Engineering and Technology, Arab Academy for Science, Technology and Maritime Transport, Smart Village Campus, Giza, Egypt
| | - Essam Nabil
- Department of Industrial Electronics and Control Engineering, Faculty of Electronic Engineering, Menoufia University, Menouf, Egypt
| |
Collapse
|
2
|
Sanz R, García P, Romero-Vivó S, Díez JL, Bondia J. Near-optimal feedback control for postprandial glucose regulation in type 1 diabetes. ISA TRANSACTIONS 2023; 133:345-352. [PMID: 36116963 DOI: 10.1016/j.isatra.2022.06.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 04/19/2022] [Accepted: 06/26/2022] [Indexed: 06/15/2023]
Abstract
This paper is focused on feedback control of postprandial glucose levels for patients with type 1 Diabetes Mellitus. There are two important limitations that make this a challenging problem. First, the slow subcutaneous insulin pharmacokinetics that introduces a significant lag into the control loop. Second, the positivity constraint on the control action, meaning that it is not possible to remove insulin from the body. In this paper, both issues are explicitly considered in the design process using the internal model control framework, to derive a near-optimal feedback controller. Optimality is understood here as minimizing the blood glucose peak after a meal intake and, at the same time, preventing glucose values below a prescribed threshold. It is shown how the proposed controller approaches the optimal closed-loop performance as a limit case. The theoretical results are supported by a numerical example and the feasibility of the overall strategy under uncertainties is illustrated using an extended version UVa/Padova metabolic simulator.
Collapse
Affiliation(s)
- R Sanz
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain.
| | - P García
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain.
| | - S Romero-Vivó
- Instituto de Matemática Multidisciplinar, Universitat Politècnica de València, 46022 València, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, 28029 Madrid, Spain.
| | - J L Díez
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, 28029 Madrid, Spain.
| | - J Bondia
- Instituto de Automática e Informática Industrial, Universitat Politècnica de València, 46022 València, Spain; Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas, Instituto de Salud Carlos III, 28029 Madrid, Spain.
| |
Collapse
|
3
|
Viroonluecha P, Egea-Lopez E, Santa J. Evaluation of blood glucose level control in type 1 diabetic patients using deep reinforcement learning. PLoS One 2022; 17:e0274608. [PMID: 36099285 PMCID: PMC9469983 DOI: 10.1371/journal.pone.0274608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 08/30/2022] [Indexed: 11/18/2022] Open
Abstract
Diabetes mellitus is a disease associated with abnormally high levels of blood glucose due to a lack of insulin. Combining an insulin pump and continuous glucose monitor with a control algorithm to deliver insulin is an alternative to patient self-management of insulin doses to control blood glucose levels in diabetes mellitus patients. In this work, we propose a closed-loop control for blood glucose levels based on deep reinforcement learning. We describe the initial evaluation of several alternatives conducted on a realistic simulator of the glucoregulatory system and propose a particular implementation strategy based on reducing the frequency of the observations and rewards passed to the agent, and using a simple reward function. We train agents with that strategy for three groups of patient classes, evaluate and compare it with alternative control baselines. Our results show that our method is able to outperform baselines as well as similar recent proposals, by achieving longer periods of safe glycemic state and low risk.
Collapse
Affiliation(s)
- Phuwadol Viroonluecha
- Universidad Politecnica de Cartagena (UPCT), Department of Information Technologies and Communications, Cartagena, Spain
- * E-mail:
| | - Esteban Egea-Lopez
- Universidad Politecnica de Cartagena (UPCT), Department of Information Technologies and Communications, Cartagena, Spain
| | - Jose Santa
- Universidad Politecnica de Cartagena (UPCT), Department of Electronics, Computer Technology and Projects, Cartagena, Spain
| |
Collapse
|
4
|
Rosales N, De Battista H, Garelli F. Hypoglycemia prevention: PID-type controller adaptation for glucose rate limiting in Artificial Pancreas System. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2021.103106] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
5
|
Biester T, Tauschmann M, Chobot A, Kordonouri O, Danne T, Kapellen T, Dovc K. The automated pancreas: A review of technologies and clinical practice. Diabetes Obes Metab 2022; 24 Suppl 1:43-57. [PMID: 34658126 DOI: 10.1111/dom.14576] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 10/07/2021] [Accepted: 10/07/2021] [Indexed: 12/12/2022]
Abstract
Insulin pumps and glucose sensors are effective in improving diabetes therapy and reducing acute complications. The combination of both devices using an algorithm-driven interoperable controller makes automated insulin delivery (AID) systems possible. Many AID systems have been tested in clinical trials and have proven safety and effectiveness. However, currently, none of these systems are available for routine use in children younger than 6 years in Europe. For continued use, both users and prescribers must have sound knowledge of the features of the individual AID systems. Presently, all systems require various user interactions (e.g. meal announcements) because fully automated systems are not yet developed. Open-source systems are non-regulated variants to circumvent existing regulatory conditions. There are risks here for both users and prescribers. To evaluate AID therapy, the metric data of the glucose sensors, 'time in target range' and 'glucose management index', are novel recognized and suitable parameters allowing a consultation based on real glucose and insulin pump download data from the daily life of people with diabetes. Read out via cloud-based software or automatic download of such individual treatment data provides the ideal technical basis for shared decision-making through telemedicine, which must be further evaluated for general use.
Collapse
Affiliation(s)
- Torben Biester
- AUF DER BULT, Diabetes Center for Children and Adolescents, Hannover, Germany
| | - Martin Tauschmann
- Department of Pediatric and Adolescent Medicine, Medical University of Vienna, Vienna, Austria
| | - Agata Chobot
- Department of Pediatrics, Institute of Medical Sciences, University of Opole, Opole, Poland
| | - Olga Kordonouri
- AUF DER BULT, Diabetes Center for Children and Adolescents, Hannover, Germany
| | - Thomas Danne
- AUF DER BULT, Diabetes Center for Children and Adolescents, Hannover, Germany
| | - Thomas Kapellen
- Department of Pediatrics, MEDIAN Clinic for Children 'Am Nicolausholz' Bad Kösen, Naumburg, Germany
| | - Klemen Dovc
- Department of Pediatric Endocrinology, Diabetes and Metabolic Diseases, UMC - University Children's Hospital, Ljubljana, Slovenia and Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
6
|
|
7
|
Automatic blood glucose control for type 1 diabetes: A trade-off between postprandial hyperglycemia and hypoglycemia. Biomed Signal Process Control 2019. [DOI: 10.1016/j.bspc.2019.101603] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
8
|
Chakrabarty A, Gregory JM, Moore LM, Williams PE, Farmer B, Cherrington AD, Lord P, Shelton B, Cohen D, Zisser HC, Doyle FJ, Dassau E. A New Animal Model of Insulin-Glucose Dynamics in the Intraperitoneal Space Enhances Closed-Loop Control Performance. JOURNAL OF PROCESS CONTROL 2019; 76:62-73. [PMID: 31178632 PMCID: PMC6548466 DOI: 10.1016/j.jprocont.2019.01.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Current artificial pancreas systems (AP) operate via subcutaneous (SC) glucose sensing and SC insulin delivery. Due to slow diffusion and transport dynamics across the interstitial space, even the most sophisticated control algorithms in on-body AP systems cannot react fast enough to maintain tight glycemic control under the effect of exogenous glucose disturbances caused by ingesting meals or performing physical activity. Recent efforts made towards the development of an implantable AP have explored the utility of insulin infusion in the intraperitoneal (IP) space: a region within the abdominal cavity where the insulin-glucose kinetics are observed to be much more rapid than the SC space. In this paper, a series of canine experiments are used to determine the dynamic association between IP insulin boluses and plasma glucose levels. Data from these experiments are employed to construct a new mathematical model and to formulate a closed-loop control strategy to be deployed on an implantable AP. The potential of the proposed controller is demonstrated via in-silico experiments on an FDA-accepted benchmark cohort: the proposed design significantly outperforms a previous controller designed using artificial data (time in clinically acceptable glucose range: 97.3±1.5% vs. 90.1±5.6%). Furthermore, the robustness of the proposed closed-loop system to delays and noise in the measurement signal (for example, when glucose is sensed subcutaneously) and deleterious glycemic changes (such as sudden glucose decline due to physical activity) is investigated. The proposed model based on experimental canine data leads to the generation of more effective control algorithms and is a promising step towards fully automated and implantable artificial pancreas systems.
Collapse
Affiliation(s)
- Ankush Chakrabarty
- Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA
| | | | - L. Merkle Moore
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, TN
| | - Philip E. Williams
- Section of Surgical Sciences, Vanderbilt University School of Medicine, Nashville, TN
| | - Ben Farmer
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, TN
| | - Alan D. Cherrington
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, TN
| | | | | | - Don Cohen
- Physiologic Devices, Inc., Alpine, CA
| | - Howard C. Zisser
- Department of Chemical Engineering, University of California Santa Barbara, Santa Barbara, CA
| | - Francis J. Doyle
- Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA
| | - Eyal Dassau
- Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA
| |
Collapse
|
9
|
Ramkissoon CM, Bertachi A, Beneyto A, Bondia J, Vehi J. Detection and Control of Unannounced Exercise in the Artificial Pancreas Without Additional Physiological Signals. IEEE J Biomed Health Inform 2019; 24:259-267. [PMID: 30763250 DOI: 10.1109/jbhi.2019.2898558] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The purpose of this study was to develop an algorithm that detects aerobic exercise and triggers disturbance rejection actions to prevent exercise-induced hypoglycemia. This approach can provide a solution to poor glycemic control during and after aerobic exercise, a major hindrance in the participation of exercise by patients with type 1 diabetes. This novel exercise-induced hypoglycemia reduction algorithm (EHRA) detects exercise using a threshold on a disturbance term, a parameter estimated from an augmented minimal model using an unscented Kalman filter. After detection, the EHRA triggers the following three actions: First, a carbohydrate suggestion, second, a reduction in basal insulin and the insulin-on-board maximum limit, and finally, a 30% reduction of the next insulin meal bolus. The EHRA was tested in silico using a 15-day scenario with 8 exercise sessions of 50 min at [Formula: see text] on alternating days. The EHRA was able to obtain improved results when compared to strategies with and without exercise announcement. The unannounced, announced, and EHRA strategies all obtained an overall percentage of time in range (70-180 mg/dl) of 94% and a percentage of time 70 mg/dl of 2%, 0%, and 0%, respectively. The EHRA was tested for robustness during exercise sessions of +25% and -25% intensity and results suggest that the EHRA is able to account for variability in exercise intensity, duration, and patient dynamics such as glucose uptake rate and insulin sensitivity.
Collapse
|
10
|
Beneyto A, Vehi J. Postprandial fuzzy adaptive strategy for a hybrid proportional derivative controller for the artificial pancreas. Med Biol Eng Comput 2018; 56:1973-1986. [PMID: 29725915 DOI: 10.1007/s11517-018-1832-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Accepted: 04/19/2018] [Indexed: 11/24/2022]
Abstract
This paper presents a support fuzzy adaptive system for a hybrid proportional derivative controller that will refine its parameters during postprandial periods to enhance performance. Even though glucose controllers have improved over the last decade, tuning them and keeping them tuned are still major challenges. Changes in a patient's lifestyle, stress, exercise, or other activities may modify their blood glucose system, making it necessary to retune or change the insulin dosing algorithm. This paper presents a strategy to adjust the parameters of a proportional derivative controller using the so-called safety auxiliary feedback element loop for type 1 diabetic patients. The main parameters, such as the insulin on board limit and proportional gain are tuned using postprandial performance indexes and the information given by the controller itself. The adaptive and robust performance of the control algorithm was assessed "in silico" on a cohort of virtual patients under challenging realistic scenarios considering mixed meals, circadian variations, time-varying uncertainties, sensor errors, and other disturbances. The results showed that an adaptive strategy can significantly improve the performance of postprandial glucose control, individualizing the tuning by directly taking into account the intra-patient variability of type 1 patients. Graphical Abstract title: Postprandial glycaemia improvement via fuzzy adaptive control A fuzzy inference engine was implemented within a clinically tested artificial pancreas control system. The aim of the fuzzy system was to adapt controller parameters to improve postprandial blood glucose control while ensuring safety. Results show a significant improvement over time of the postprandial glucose response due to the adaptation, thus demonstrating the usefulness of the fuzzy adaptive system.
Collapse
Affiliation(s)
- Aleix Beneyto
- Institut d'Informàtica i Aplicacions, Universitat de Girona, Campus de Montilivi, s/n, Edifici P4, 17071, Girona, Spain
| | - Josep Vehi
- Institut d'Informàtica i Aplicacions, Universitat de Girona, Campus de Montilivi, s/n, Edifici P4, 17071, Girona, Spain. .,CIBERDEM, Girona, Spain.
| |
Collapse
|
11
|
Artificial pancreas clinical trials: Moving towards closed-loop control using insulin-on-board constraints. Biomed Signal Process Control 2018. [DOI: 10.1016/j.bspc.2018.05.009] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
12
|
Hajizadeh I, Rashid M, Samadi S, Feng J, Sevil M, Hobbs N, Lazaro C, Maloney Z, Brandt R, Yu X, Turksoy K, Littlejohn E, Cengiz E, Cinar A. Adaptive and Personalized Plasma Insulin Concentration Estimation for Artificial Pancreas Systems. J Diabetes Sci Technol 2018; 12:639-649. [PMID: 29566547 PMCID: PMC6154239 DOI: 10.1177/1932296818763959] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND The artificial pancreas (AP) system, a technology that automatically administers exogenous insulin in people with type 1 diabetes mellitus (T1DM) to regulate their blood glucose concentrations, necessitates the estimation of the amount of active insulin already present in the body to avoid overdosing. METHOD An adaptive and personalized plasma insulin concentration (PIC) estimator is designed in this work to accurately quantify the insulin present in the bloodstream. The proposed PIC estimation approach incorporates Hovorka's glucose-insulin model with the unscented Kalman filtering algorithm. Methods for the personalized initialization of the time-varying model parameters to individual patients for improved estimator convergence are developed. Data from 20 three-days-long closed-loop clinical experiments conducted involving subjects with T1DM are used to evaluate the proposed PIC estimation approach. RESULTS The proposed methods are applied to the clinical data containing significant disturbances, such as unannounced meals and exercise, and the results demonstrate the accurate real-time estimation of the PIC with the root mean square error of 7.15 and 9.25 mU/L for the optimization-based fitted parameters and partial least squares regression-based testing parameters, respectively. CONCLUSIONS The accurate real-time estimation of PIC will benefit the AP systems by preventing overdelivery of insulin when significant insulin is present in the bloodstream.
Collapse
Affiliation(s)
- Iman Hajizadeh
- Department of Chemical and Biological
Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Mudassir Rashid
- Department of Chemical and Biological
Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Sediqeh Samadi
- Department of Chemical and Biological
Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Jianyuan Feng
- Department of Chemical and Biological
Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Mert Sevil
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Nicole Hobbs
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Caterina Lazaro
- Department of Electrical and Computer
Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Zacharie Maloney
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Rachel Brandt
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Xia Yu
- School of Information Science and
Technology, Northeastern University, Shenyang, China
| | - Kamuran Turksoy
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Elizabeth Littlejohn
- Department of Pediatrics and Medicine,
Section of Endocrinology, Kovler Diabetes Center, University of Chicago, Chicago,
IL, USA
| | - Eda Cengiz
- Department of Pediatrics, Yale
University School of Medicine, New Haven, CT, USA
| | - Ali Cinar
- Department of Chemical and Biological
Engineering, Illinois Institute of Technology, Chicago, IL, USA
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
- Ali Cinar, PhD, Illinois Institute of
Technology, Department of Chemical and Biological Engineering, 10 W 33rd St,
Chicago, IL 60616, USA.
| |
Collapse
|
13
|
Hajizadeh I, Rashid M, Turksoy K, Samadi S, Feng J, Frantz N, Sevil M, Cengiz E, Cinar A. Plasma Insulin Estimation in People with Type 1 Diabetes Mellitus. Ind Eng Chem Res 2017. [DOI: 10.1021/acs.iecr.7b01618] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
| | | | | | | | | | | | | | - Eda Cengiz
- Department
of Pediatrics, Yale University School of Medicine, New Haven, Connecticut 06437-2411, United States
| | | |
Collapse
|
14
|
Kovács L. Linear parameter varying (LPV) based robust control of type-I diabetes driven for real patient data. Knowl Based Syst 2017. [DOI: 10.1016/j.knosys.2017.02.008] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
15
|
Ilkowitz JT, Katikaneni R, Cantwell M, Ramchandani N, Heptulla RA. Adjuvant Liraglutide and Insulin Versus Insulin Monotherapy in the Closed-Loop System in Type 1 Diabetes: A Randomized Open-Labeled Crossover Design Trial. J Diabetes Sci Technol 2016; 10:1108-14. [PMID: 27184690 PMCID: PMC5032955 DOI: 10.1177/1932296816647976] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The closed-loop (CL) system delivers insulin in a glucose-responsive manner and optimal postprandial glycemic control is difficult to achieve with the algorithm and insulin available. We hypothesized that adjunctive therapy with liraglutide, a once-daily glucagon-like peptide-1 agonist, would be more effective in normalizing postprandial hyperglycemia versus insulin monotherapy in the CL system, in patients with type 1 diabetes. METHODS This was a randomized, controlled, open-label, crossover design trial comparing insulin monotherapy versus adjuvant subcutaneous liraglutide 1.2 mg and insulin, using the CL system in 15 patients. Blood glucose (BG), insulin, and glucagon concentrations were analyzed. RESULTS The liraglutide arm was associated with overall decreased mean BG levels (P = .0002). The average BG levels from 8:00 pm (day 1) to 9:00 pm (day 2) were lower in the liraglutide arm (144.6 ± 36.31 vs 159.7 ± 50.88 mg/dl respectively; P = .0002). Two-hour postbreakfast and lunch BG profiles were better in the liraglutide arm (P < .05) and the insulin and glucagon assay values were lower (P < .0001). Postprandially, the area under the curve (AUC) for 2-hour postbreakfast and lunch BG levels were significant (P = .01, P = .03) and the AUC for glucagon, postbreakfast (P < .0001) and lunch (P < .05), was also significant. The incidence of hypoglycemia did not differ between arms (P = .83, Fisher's exact test). Overall, adjunct liraglutide therapy plus CL was well tolerated even with expected side effects. CONCLUSION This is a proof-of-concept study showing liraglutide can be a potential adjunctive therapy in addition to CL with insulin to reduce postprandial hyperglycemia in type 1 diabetes.
Collapse
Affiliation(s)
- Jeniece Trast Ilkowitz
- Department of Pediatrics, Division of Endocrinology and Diabetes, Children's Hospital at Montefiore, Bronx, NY, USA
| | - Ranjitha Katikaneni
- Department of Pediatrics, Division of Endocrinology and Diabetes, Children's Hospital at Montefiore, Bronx, NY, USA
| | | | - Neesha Ramchandani
- Department of Pediatrics, Division of Endocrinology and Diabetes, Children's Hospital at Montefiore, Bronx, NY, USA
| | - Rubina A Heptulla
- Department of Pediatrics, Division of Endocrinology and Diabetes, Children's Hospital at Montefiore, Bronx, NY, USA Division Chief, Pediatric, Endocrinology and Diabetes, Albert Einstein College of Medicine, Children's Hospital at Montefiore, NY, USA
| |
Collapse
|
16
|
Sherr JL, Patel NS, Michaud CI, Palau-Collazo MM, Van Name MA, Tamborlane WV, Cengiz E, Carria LR, Tichy EM, Weinzimer SA. Mitigating Meal-Related Glycemic Excursions in an Insulin-Sparing Manner During Closed-Loop Insulin Delivery: The Beneficial Effects of Adjunctive Pramlintide and Liraglutide. Diabetes Care 2016; 39:1127-34. [PMID: 27208332 PMCID: PMC4915555 DOI: 10.2337/dc16-0089] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Accepted: 04/11/2016] [Indexed: 02/03/2023]
Abstract
OBJECTIVE Closed-loop (CL) insulin delivery effectively maintains glucose overnight but struggles when challenged with meals. Use of single-day, 30-μg/meal pramlintide lowers meal excursions during CL. We sought to further elucidate the potential benefits of adjunctive agents after 3-4 weeks of outpatient dose titration. RESEARCH DESIGN AND METHODS Two CL studies were conducted: one evaluating adjunctive pramlintide and the other liraglutide. Ten subjects (age 16-23 years; A1C 7.2 ± 0.6% [55 ± 6.6 mmol/mol]) completed two 24-h sessions: one on CL alone and one on CL plus 60-μg pramlintide (CL + P), after a 3-4-week outpatient dose escalation. Eleven subjects (age 18-27 years; A1C 7.5 ± 0.9% [58 ± 9.8 mmol/mol]) were studied before and after treatment with 1.8 mg liraglutide (CL + L) after a similar 3-4-week dose escalation period. Timing and content of meals during CL were identical within experiments; meals were not announced. RESULTS Pramlintide delayed the time to peak plasma glucose (PG) excursion (CL 1.6 ± 0.5 h vs. CL + P 2.6 ± 0.9 h, P < 0.001) with concomitant blunting of peak postprandial increments in PG (P < 0.0001) and reductions in postmeal incremental PG area under the curve (AUC) (P = 0.0002). CL + L also led to reductions in PG excursions (P = 0.05) and incremental PG AUC (P = 0.004), with a 28% reduction in prandial insulin delivery. Outpatient liraglutide therapy led to a weight loss of 3.2 ± 1.8 kg, with a 26% reduction in total daily insulin dose. CONCLUSIONS Adjunctive pramlintide and liraglutide treatment mitigated postprandial hyperglycemia during CL control; liraglutide demonstrated the additional benefit of weight loss in an insulin-sparing manner. Further investigations of these and other adjunctive agents in long-term outpatient CL studies are needed.
Collapse
|
17
|
Prentice B, Hameed S, Verge CF, Ooi CY, Jaffe A, Widger J. Diagnosing cystic fibrosis-related diabetes: current methods and challenges. Expert Rev Respir Med 2016; 10:799-811. [DOI: 10.1080/17476348.2016.1190646] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Bernadette Prentice
- Department of Respiratory Medicine, Sydney Children’s Hospital, Randwick, Australia
- School of Women’s and Children’s Health, The University of New South Wales, Randwick, Australia
| | - Shihab Hameed
- School of Women’s and Children’s Health, The University of New South Wales, Randwick, Australia
- Department of Endocrinology, Sydney Children’s Hospital, Randwick, Australia
| | - Charles F. Verge
- School of Women’s and Children’s Health, The University of New South Wales, Randwick, Australia
- Department of Endocrinology, Sydney Children’s Hospital, Randwick, Australia
| | - Chee Y. Ooi
- School of Women’s and Children’s Health, The University of New South Wales, Randwick, Australia
- Department of Gastroenterology, Sydney Children’s Hospital, Randwick, Australia
| | - Adam Jaffe
- Department of Respiratory Medicine, Sydney Children’s Hospital, Randwick, Australia
- School of Women’s and Children’s Health, The University of New South Wales, Randwick, Australia
| | - John Widger
- Department of Respiratory Medicine, Sydney Children’s Hospital, Randwick, Australia
- School of Women’s and Children’s Health, The University of New South Wales, Randwick, Australia
| |
Collapse
|
18
|
Szalay P, Eigner G, Kozlovszky M, Rudas I, Kovacs L. The significance of LPV modeling of a widely used T1DM model. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:3531-4. [PMID: 24110491 DOI: 10.1109/embc.2013.6610304] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The paper investigates the specificity of Linear Parameter Varying (LPV) modeling and robust controller design on a widely used Type 1 Diabetes Mellitus model. LPV systems can be seen as an extension of linear time invariant systems, which allows us to extend some powerful control methodologies to the highly nonlinear and uncertain models of the human metabolism. Different LPV models are proposed with their own advantages and disadvantages. The possible choices are separately analyzed for both controller and observer design perspective.
Collapse
|
19
|
Daskalaki E, Diem P, Mougiakakou SG. Personalized tuning of a reinforcement learning control algorithm for glucose regulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:3487-90. [PMID: 24110480 DOI: 10.1109/embc.2013.6610293] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Artificial pancreas is in the forefront of research towards the automatic insulin infusion for patients with type 1 diabetes. Due to the high inter- and intra-variability of the diabetic population, the need for personalized approaches has been raised. This study presents an adaptive, patient-specific control strategy for glucose regulation based on reinforcement learning and more specifically on the Actor-Critic (AC) learning approach. The control algorithm provides daily updates of the basal rate and insulin-to-carbohydrate (IC) ratio in order to optimize glucose regulation. A method for the automatic and personalized initialization of the control algorithm is designed based on the estimation of the transfer entropy (TE) between insulin and glucose signals. The algorithm has been evaluated in silico in adults, adolescents and children for 10 days. Three scenarios of initialization to i) zero values, ii) random values and iii) TE-based values have been comparatively assessed. The results have shown that when the TE-based initialization is used, the algorithm achieves faster learning with 98%, 90% and 73% in the A+B zones of the Control Variability Grid Analysis for adults, adolescents and children respectively after five days compared to 95%, 78%, 41% for random initialization and 93%, 88%, 41% for zero initial values. Furthermore, in the case of children, the daily Low Blood Glucose Index reduces much faster when the TE-based tuning is applied. The results imply that automatic and personalized tuning based on TE reduces the learning period and improves the overall performance of the AC algorithm.
Collapse
|
20
|
Huyett LM, Dassau E, Zisser HC, Doyle FJ. Design and Evaluation of a Robust PID Controller for a Fully Implantable Artificial Pancreas. Ind Eng Chem Res 2015; 54:10311-10321. [PMID: 26538805 PMCID: PMC4627627 DOI: 10.1021/acs.iecr.5b01237] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2015] [Revised: 06/06/2015] [Accepted: 06/09/2015] [Indexed: 11/28/2022]
Abstract
Treatment of type 1 diabetes mellitus could be greatly improved by applying a closed-loop control strategy to insulin delivery, also known as an artificial pancreas (AP). In this work, we outline the design of a fully implantable AP using intraperitoneal (IP) insulin delivery and glucose sensing. The design process utilizes the rapid glucose sensing and insulin action offered by the IP space to tune a PID controller with insulin feedback to provide safe and effective insulin delivery. The controller was tuned to meet robust performance and stability specifications. An anti-reset windup strategy was introduced to prevent dangerous undershoot toward hypoglycemia after a large meal disturbance. The final controller design achieved 78% of time within the tight glycemic range of 80-140 mg/dL, with no time spent in hypoglycemia. The next step is to test this controller design in an animal model to evaluate the in vivo performance.
Collapse
Affiliation(s)
- Lauren M Huyett
- Department of Chemical Engineering, University of California Santa Barbara , Santa Barbara, California 93106-5080, United States
| | - Eyal Dassau
- Department of Chemical Engineering, University of California Santa Barbara , Santa Barbara, California 93106-5080, United States
| | - Howard C Zisser
- Department of Chemical Engineering, University of California Santa Barbara , Santa Barbara, California 93106-5080, United States
| | - Francis J Doyle
- Department of Chemical Engineering, University of California Santa Barbara , Santa Barbara, California 93106-5080, United States
| |
Collapse
|
21
|
León-Vargas F, Garelli F, De Battista H, Vehí J. Postprandial response improvement via safety layer in closed-loop blood glucose controllers. Biomed Signal Process Control 2015. [DOI: 10.1016/j.bspc.2014.10.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
22
|
Cobelli C, Man CD, Pedersen MG, Bertoldo A, Toffolo G. Advancing our understanding of the glucose system via modeling: a perspective. IEEE Trans Biomed Eng 2015; 61:1577-92. [PMID: 24759285 DOI: 10.1109/tbme.2014.2310514] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The glucose story begins with Claude Bernard's discovery of glycogen and milieu interieur, continued with Banting's and Best's discovery of insulin and with Rudolf Schoenheimer's paradigm of dynamic body constituents. Tracers and compartmental models allowed moving to the first quantitative pictures of the system and stimulated important developments in terms of modeling methodology. Three classes of multiscale models, models to measure, models to simulate, and models to control the glucose system, are reviewed in their historical development with an eye to the future.
Collapse
|
23
|
Ramkissoon CM, Aufderheide B, Bequette BW, Palerm CC. A model of glucose-insulin-pramlintide pharmacokinetics and pharmacodynamics in type I diabetes. J Diabetes Sci Technol 2014; 8:529-42. [PMID: 24876617 PMCID: PMC4455443 DOI: 10.1177/1932296813517323] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Type 1 diabetes mellitus (T1DM) complications are significantly reduced when normoglycemic levels are maintained via intensive therapy. The artificial pancreas is designed for intensive glycemic control; however, large postprandial excursions after a meal result in poor glucose regulation. Pramlintide, a synthetic analog of the hormone amylin, reduces the severity of postprandial excursions by reducing appetite, suppressing glucagon release, and slowing the rate of gastric emptying. The goal of this study is to create a glucose-insulin-pramlintide physiological model that can be employed into a controller to improve current control approaches used in the artificial pancreas. A model of subcutaneous (SC) pramlintide pharmacokinetics (PK) was developed by revising an intravenous (IV) pramlintide PK model and adapting SC insulin PK from a glucose-insulin model. Gray-box modeling and least squares optimization were used to obtain parameter estimates. Pharmacodynamics (PD) were obtained by choosing parameters most applicable to pramlintide mechanisms and then testing using a proportional PD effect using least squares optimization. The model was fit and validated using 27 data sets, which included placebo, PK, and PD data. SC pramlintide PK root mean square error values range from 1.98 to 10.66 pmol/L. Pramlintide PD RMSE values range from 10.48 to 42.76 mg/dL. A new in silico model of the glucose-insulin-pramlintide regulatory system is presented. This model can be used as a platform to optimize dosing of both pramlintide and insulin as a combined therapy for glycemic regulation, and in the development of an artificial pancreas as the kernel for a model-based controller.
Collapse
Affiliation(s)
| | - Brian Aufderheide
- Department of Process Engineering, University of Trinidad and Tobago, Trinidad W.I.
| | - B Wayne Bequette
- Department of Chemical & Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
| | | |
Collapse
|
24
|
Szalay P, Eigner G, Kovács LA. Linear Matrix Inequality-based Robust Controller design for Type-1 Diabetes Model. ACTA ACUST UNITED AC 2014. [DOI: 10.3182/20140824-6-za-1003.02451] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
25
|
León-Vargas F, Garelli F, De Battista H, Vehí J. Postprandial blood glucose control using a hybrid adaptive PD controller with insulin-on-board limitation. Biomed Signal Process Control 2013. [DOI: 10.1016/j.bspc.2013.06.008] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
26
|
Sherr JL, Cengiz E, Palerm CC, Clark B, Kurtz N, Roy A, Carria L, Cantwell M, Tamborlane WV, Weinzimer SA. Reduced hypoglycemia and increased time in target using closed-loop insulin delivery during nights with or without antecedent afternoon exercise in type 1 diabetes. Diabetes Care 2013; 36:2909-14. [PMID: 23757427 PMCID: PMC3781513 DOI: 10.2337/dc13-0010] [Citation(s) in RCA: 82] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVE Afternoon exercise increases the risk of nocturnal hypoglycemia (NH) in subjects with type 1 diabetes. We hypothesized that automated feedback-controlled closed-loop (CL) insulin delivery would be superior to open-loop (OL) control in preventing NH and maintaining a higher proportion of blood glucose levels within the target blood glucose range on nights with and without antecedent afternoon exercise. RESEARCH DESIGN AND METHODS Subjects completed two 48-h inpatient study periods in random order: usual OL control and CL control using a proportional-integrative-derivative plus insulin feedback algorithm. Each admission included a sedentary day and an exercise day, with a standardized protocol of 60 min of brisk treadmill walking to 65-70% maximum heart rate at 3:00 p.m. RESULTS Among 12 subjects (age 12-26 years, A1C 7.4±0.6%), antecedent exercise increased the frequency of NH (reference blood glucose<60 mg/dL) during OL control from six to eight events. In contrast, there was only one NH event each on nights with and without antecedent exercise during CL control (P=0.04 vs. OL nights). Overnight, the percentage of glucose values in target range was increased with CL control (P<0.0001). Insulin delivery was lower between 10:00 p.m. and 2:00 a.m. on nights after exercise on CL versus OL, P=0.008. CONCLUSIONS CL insulin delivery provides an effective means to reduce the risk of NH while increasing the percentage of time spent in target range, regardless of activity level in the mid-afternoon. These data suggest that CL control could be of benefit to patients with type 1 diabetes even if it is limited to the overnight period.
Collapse
|
27
|
Schmidt S, Boiroux D, Duun-Henriksen AK, Frøssing L, Skyggebjerg O, Jørgensen JB, Poulsen NK, Madsen H, Madsbad S, Nørgaard K. Model-based closed-loop glucose control in type 1 diabetes: the DiaCon experience. J Diabetes Sci Technol 2013; 7:1255-64. [PMID: 24124952 PMCID: PMC3876369 DOI: 10.1177/193229681300700515] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND To improve type 1 diabetes mellitus (T1DM) management, we developed a model predictive control (MPC) algorithm for closed-loop (CL) glucose control based on a linear second-order deterministic-stochastic model. The deterministic part of the model is specified by three patient-specific parameters: insulin sensitivity factor, insulin action time, and basal insulin infusion rate. The stochastic part is identical for all patients but identified from data from a single patient. Results of the first clinical feasibility test of the algorithm are presented. METHODS We conducted two randomized crossover studies. Study 1 compared CL with open-loop (OL) control. Study 2 compared glucose control after CL initiation in the euglycemic (CL-Eu) and hyperglycemic (CL-Hyper) ranges, respectively. Patients were studied from 22:00-07:00 on two separate nights. RESULTS Each study included six T1DM patients (hemoglobin A1c 7.2% ± 0.4%). In study 1, hypoglycemic events (plasma glucose < 54 mg/dl) occurred on two OL and one CL nights. Average glucose from 22:00-07:00 was 90 mg/dl [74-146 mg/dl; median (interquartile range)] during OL and 108 mg/dl (101-128 mg/dl) during CL (determined by continuous glucose monitoring). However, median time spent in the range 70-144 mg/dl was 67.9% (3.0-73.3%) during OL and 80.8% (70.5-89.7%) during CL. In study 2, there was one episode of hypoglycemia with plasma glucose <54 mg/dl in a CL-Eu night. Mean glucose from 22:00-07:00 and time spent in the range 70-144 mg/dl were 121 mg/dl (117-133 mg/dl) and 69.0% (30.7-77.9%) in CL-Eu and 149 mg/dl (140-193 mg/dl) and 48.2% (34.9-72.5%) in CL-Hyper, respectively. CONCLUSIONS This study suggests that our novel MPC algorithm can safely and effectively control glucose overnight, also when CL control is initiated during hyperglycemia.
Collapse
Affiliation(s)
- Signe Schmidt
- Department of Endocrinology, Copenhagen University Hospital Hvidovre, Kettegård Alle 30, 2650 Hvidovre, Denmark.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Kovacs L, Szalay P, Almássy Z, Barkai L. Applicability results of a nonlinear model-based robust blood glucose control algorithm. J Diabetes Sci Technol 2013; 7:708-16. [PMID: 23759404 PMCID: PMC3869139 DOI: 10.1177/193229681300700316] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
INTRODUCTION Generating optimal control algorithms for an artificial pancreas is an intensively researched problem. The available models are all nonlinear and rather complex. Model predictive control or run-to-run-based methodologies have proven to be efficient solutions for individualized treatment of type 1 diabetes mellitus (T1DM). However, the controller has to ensure safety and stability under all circumstances. Robust control methods seek to provide this safety and guarantee to handle even the worst-case situations and, hence, to generalize and complement results obtained by individualized control algorithms. METHODS Modern robust (e.g., Hinf) control is a linear model-based methodology that we have combined with the nonlinear model-based linear parameter varying technique. The control algorithm was designed on the high-complexity modified nonlinear glucose-insulin model of Sorensen, and it was compared step-by-step with linear model-based Hinf control results published in the literature. The applicability of the developed algorithm was tested first on a control cohort of 10 healthy persons' oral glucose tolerance test results and then on a large meal absorption profile adapted from the literature. In the latter case, two preliminary virtual patients were generated based on 1-1 week real continuous glucose monitor measurements. RESULTS We have found that the algorithm avoids hypoglycemia (not caused by physical activity or stress) independently from the considered absorption profiles. CONCLUSION Use of hard constraints proved their efficiency in fitting blood glucose level within a defined interval. However, in the future, more data of different T1DM patients will be collected and tested, including dynamic absorption model and in silico tests on validated simulators.
Collapse
Affiliation(s)
- Levente Kovacs
- Óbuda University, John von Neumann Faculty of Informatics, Bécsi út 96/b, Budapest, Hungary.
| | | | | | | |
Collapse
|
29
|
Abbes IB, Richard PY, Lefebvre MA, Guilhem I, Poirier JY. A closed-loop artificial pancreas using a proportional integral derivative with double phase lead controller based on a new nonlinear model of glucose metabolism. J Diabetes Sci Technol 2013; 7:699-707. [PMID: 23759403 PMCID: PMC3869138 DOI: 10.1177/193229681300700315] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
BACKGROUND Most closed-loop insulin delivery systems rely on model-based controllers to control the blood glucose (BG) level. Simple models of glucose metabolism, which allow easy design of the control law, are limited in their parametric identification from raw data. New control models and controllers issued from them are needed. METHODS A proportional integral derivative with double phase lead controller was proposed. Its design was based on a linearization of a new nonlinear control model of the glucose-insulin system in type 1 diabetes mellitus (T1DM) patients validated with the University of Virginia/Padova T1DM metabolic simulator. A 36 h scenario, including six unannounced meals, was tested in nine virtual adults. A previous trial database has been used to compare the performance of our controller with their previous results. The scenario was repeated 25 times for each adult in order to take continuous glucose monitoring noise into account. The primary outcome was the time BG levels were in target (70-180 mg/dl). RESULTS Blood glucose values were in the target range for 77% of the time and below 50 mg/dl and above 250 mg/dl for 0.8% and 0.3% of the time, respectively. The low blood glucose index and high blood glucose index were 1.65 and 3.33, respectively. CONCLUSION The linear controller presented, based on the linearization of a new easily identifiable nonlinear model, achieves good glucose control with low exposure to hypoglycemia and hyperglycemia.
Collapse
Affiliation(s)
- Ilham Ben Abbes
- Supelec/I.E.T.R., Avenue de la Boulaie, Cesson-Sévigné Cedex, France.
| | | | | | | | | |
Collapse
|
30
|
Turksoy K, Bayrak ES, Quinn L, Littlejohn E, Cinar A. Multivariable adaptive closed-loop control of an artificial pancreas without meal and activity announcement. Diabetes Technol Ther 2013; 15:386-400. [PMID: 23544672 PMCID: PMC3643229 DOI: 10.1089/dia.2012.0283] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
BACKGROUND Accurate closed-loop control is essential for developing artificial pancreas (AP) systems that adjust insulin infusion rates from insulin pumps. Glucose concentration information from continuous glucose monitoring (CGM) systems is the most important information for the control system. Additional physiological measurements can provide valuable information that can enhance the accuracy of the control system. Proportional-integral-derivative control and model predictive control have been popular in AP development. Their implementations to date rely on meal announcements (e.g., bolus insulin dose based on insulin:carbohydrate ratios) by the user. Adaptive control techniques provide a powerful alternative that do not necessitate any meal or activity announcements. MATERIALS AND METHODS Adaptive control systems based on the generalized predictive control framework are developed by extending the recursive modeling techniques. Physiological signals such as energy expenditure and galvanic skin response are used along with glucose measurements to generate a multiple-input-single-output model for predicting future glucose concentrations used by the controller. Insulin-on-board (IOB) is also estimated and used in control decisions. The controllers were tested with clinical studies that include seven cases with three different patients with type 1 diabetes for 32 or 60 h without any meal or activity announcements. RESULTS The adaptive control system kept glucose concentration in the normal preprandial and postprandial range (70-180 mg/dL) without any meal or activity announcements during the test period. After IOB estimation was added to the control system, mild hypoglycemic episodes were observed only in one of the four experiments. This was reflected in a plasma glucose value of 56 mg/dL (YSI 2300 STAT; Yellow Springs Instrument, Yellow Springs, OH) and a CGM value of 63 mg/dL). CONCLUSIONS Regulation of blood glucose concentration with an AP using adaptive control techniques was successful in clinical studies, even without any meal and physical activity announcement.
Collapse
Affiliation(s)
- Kamuran Turksoy
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Elif Seyma Bayrak
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, Illinois
| | - Lauretta Quinn
- College of Nursing, University of Illinois Chicago, Chicago, Illinois
| | | | - Ali Cinar
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Illinois
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, Illinois
| |
Collapse
|
31
|
Revert A, Garelli F, Pico J, De Battista H, Rossetti P, Vehi J, Bondia J. Safety auxiliary feedback element for the artificial pancreas in type 1 diabetes. IEEE Trans Biomed Eng 2013; 60:2113-22. [PMID: 23428611 DOI: 10.1109/tbme.2013.2247602] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The artificial pancreas aims at the automatic delivery of insulin for glycemic control in patients with type 1 diabetes, i.e., closed-loop glucose control. One of the challenges of the artificial pancreas is to avoid controller overreaction leading to hypoglycemia, especially in the late postprandial period. In this study, an original proposal based on sliding mode reference conditioning ideas is presented as a way to reduce hypoglycemia events induced by a closed-loop glucose controller. The method is inspired in the intuitive advantages of two-step constrained control algorithms. It acts on the glucose reference sent to the main controller shaping it so as to avoid violating given constraints on the insulin-on-board. Some distinctive features of the proposed strategy are that 1) it provides a safety layer which can be adjusted according to medical criteria; 2) it can be added to closed-loop controllers of any nature; 3) it is robust against sensor failures and overestimated prandial insulin doses; and 4) it can handle nonlinear models. The method is evaluated in silico with the ten adult patients available in the FDA-accepted UVA simulator.
Collapse
Affiliation(s)
- A Revert
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Valencia 46022, Spain.
| | | | | | | | | | | | | |
Collapse
|
32
|
Daskalaki E, Diem P, Mougiakakou SG. An Actor-Critic based controller for glucose regulation in type 1 diabetes. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2013; 109:116-125. [PMID: 22502983 DOI: 10.1016/j.cmpb.2012.03.002] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2011] [Revised: 02/29/2012] [Accepted: 03/08/2012] [Indexed: 05/31/2023]
Abstract
A novel adaptive approach for glucose control in individuals with type 1 diabetes under sensor-augmented pump therapy is proposed. The controller, is based on Actor-Critic (AC) learning and is inspired by the principles of reinforcement learning and optimal control theory. The main characteristics of the proposed controller are (i) simultaneous adjustment of both the insulin basal rate and the bolus dose, (ii) initialization based on clinical procedures, and (iii) real-time personalization. The effectiveness of the proposed algorithm in terms of glycemic control has been investigated in silico in adults, adolescents and children under open-loop and closed-loop approaches, using announced meals with uncertainties in the order of ±25% in the estimation of carbohydrates. The results show that glucose regulation is efficient in all three groups of patients, even with uncertainties in the level of carbohydrates in the meal. The percentages in the A+B zones of the Control Variability Grid Analysis (CVGA) were 100% for adults, and 93% for both adolescents and children. The AC based controller seems to be a promising approach for the automatic adjustment of insulin infusion in order to improve glycemic control. After optimization of the algorithm, the controller will be tested in a clinical trial.
Collapse
Affiliation(s)
- Elena Daskalaki
- ARTORG Center for Biomedical Engineering Research, Diabetes Technology Research Group, University of Bern, Murtenstrasse 50, 3010 Bern, Switzerland
| | | | | |
Collapse
|
33
|
Garcia-Gabin W, Jacobsen EW. Multilevel model based glucose control for type-1 diabetes patients. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2013:3917-3920. [PMID: 24110588 DOI: 10.1109/embc.2013.6610401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Diabetes is a disease that involves alterations at multiple biological levels, ranging from intracellular signalling to organ processes. Since glucose homeostasis is the consequence of complex interactions that involve a number of factors, the control of diabetes should be based on a multilevel analysis. In this paper, a novel approach to design of closed-loop glucose controllers based on multilevel models is presented. A control scheme is proposed based on combining a pharmacokinetic/pharmacodynamic model with an insulin signal transduction model for type 1 diabetes mellitus patients. Based on this, an insulin feedback control schemes is designed. Two main advantages of explicitly utilizing information at the intracellular level were obtained. First, significant reduction of hypoglycaemic risk by reducing the undershoot in glucose levels in response to added insulin. Second, robust performance for inter-patient changes, demonstrated through application of the multilevel control strategy to a well established in silico population of diabetic patients.
Collapse
|
34
|
Bequette BW. Challenges and Recent Progress in the Development of a Closed-loop Artificial Pancreas. ANNUAL REVIEWS IN CONTROL 2012; 36:255-266. [PMID: 23175620 PMCID: PMC3501007 DOI: 10.1016/j.arcontrol.2012.09.007] [Citation(s) in RCA: 85] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Pursuit of a closed-loop artificial pancreas that automatically controls the blood glucose of individuals with type 1 diabetes has intensified during the past six years. Here we discuss the recent progress and challenges in the major steps towards a closed-loop system. Continuous insulin infusion pumps have been widely available for over two decades, but "smart pump" technology has made the devices easier to use and more powerful. Continuous glucose monitoring (CGM) technology has improved and the devices are more widely available. A number of approaches are currently under study for fully closed-loop systems; most manipulate only insulin, while others manipulate insulin and glucagon. Algorithms include on-off (for prevention of overnight hypoglycemia), proportional-integral-derivative (PID), model predictive control (MPC) and fuzzy logic based learning control. Meals cause a major "disturbance" to blood glucose, and we discuss techniques that our group has developed to predict when a meal is likely to be consumed and its effect. We further examine both physiology and device-related challenges, including insulin infusion set failure and sensor signal attenuation. Finally, we discuss the next steps required to make a closed-loop artificial pancreas a commercial reality.
Collapse
|
35
|
Weinzimer SA, Sherr JL, Cengiz E, Kim G, Ruiz JL, Carria L, Voskanyan G, Roy A, Tamborlane WV. Effect of pramlintide on prandial glycemic excursions during closed-loop control in adolescents and young adults with type 1 diabetes. Diabetes Care 2012; 35:1994-9. [PMID: 22815298 PMCID: PMC3447854 DOI: 10.2337/dc12-0330] [Citation(s) in RCA: 101] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVE Even under closed-loop (CL) conditions, meal-related blood glucose (BG) excursions frequently exceed target levels as a result of delays in absorption of insulin from the subcutaneous site of infusion. We hypothesized that delaying gastric emptying with preprandial injections of pramlintide would improve postprandial glycemia by allowing a better match between carbohydrate and insulin absorptions. RESEARCH DESIGN AND METHODS Eight subjects (4 female; age, 15-28 years; A1C, 7.5 ± 0.7%) were studied for 48 h on a CL insulin-delivery system with a proportional integral derivative algorithm with insulin feedback: 24 h on CL control alone (CL) and 24 h on CL control plus 30-μg premeal injections of pramlintide (CLP). Target glucose was set at 120 mg/dL; timing and contents of meals were identical on both study days. No premeal manual boluses were given. Differences in reference BG excursions, defined as the incremental glucose rise from premeal to peak, were compared between conditions for each meal. RESULTS CLP was associated with overall delayed time to peak BG (2.5 ± 0.9 vs. 1.5 ± 0.5 h; P < 0.0001) and reduced magnitude of glycemic excursion (88 ± 42 vs. 113 ± 32 mg/dL; P = 0.006) compared with CL alone. Pramlintide effects on glycemic excursions were particularly evident at lunch and dinner, in association with higher premeal insulin concentrations at those mealtimes. CONCLUSIONS Pramlintide delayed the time to peak postprandial BG and reduced the magnitude of prandial BG excursions. Beneficial effects of pramlintide on CL may in part be related to higher premeal insulin levels at lunch and dinner compared with breakfast.
Collapse
Affiliation(s)
- Stuart A Weinzimer
- Department of Pediatrics, Yale University School of Medicine, New Haven, Connecticut, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Ruiz JL, Sherr JL, Cengiz E, Carria L, Roy A, Voskanyan G, Tamborlane WV, Weinzimer SA. Effect of insulin feedback on closed-loop glucose control: a crossover study. J Diabetes Sci Technol 2012; 6:1123-30. [PMID: 23063039 PMCID: PMC3570847 DOI: 10.1177/193229681200600517] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Closed-loop (CL) insulin delivery systems utilizing proportional-integral-derivative (PID) controllers have demonstrated susceptibility to late postprandial hypoglycemia because of delays between insulin delivery and blood glucose (BG) response. An insulin feedback (IFB) modification to the PID algorithm has been introduced to mitigate this risk. We examined the effect of IFB on CL BG control. METHODS Using the Medtronic ePID CL system, four subjects were studied for 24 h on PID control and 24 h during a separate admission with the IFB modification (PID + IFB). Target glucose was 120 mg/dl; meals were served at 8:00 AM, 1:00 PM, and 6:00 PM and were identical for both admissions. No premeal manual boluses were given. Reference BG excursions, defined as incremental glucose rise from premeal to peak, and postprandial BG area under the curve (AUC; 0-5 h) were compared. Results are reported as mean ± standard deviation. RESULTS The PID + IFB control resulted in higher mean BG levels compared with PID alone (153 ± 54 versus 133 ± 56 mg/dl; p < .0001). Postmeal BG excursions (114 ± 28 versus 114 ± 47 mg/dl) and AUCs (285 ± 102 versus 255 ± 129 mg/dl/h) were similar under both conditions. Total insulin delivery averaged 57 ± 20 U with PID versus 45 ± 13 U with PID + IFB (p = .18). Notably, eight hypoglycemic events (BG < 60 mg/dl) occurred during PID control versus none during PID + IFB. CONCLUSIONS Addition of IFB to the PID controller markedly reduced the occurrence of hypoglycemia without increasing meal-related glucose excursions. Higher average BG levels may be attributable to differences in the determination of system gain (Kp) in this study. The prevention of postprandial hypoglycemia suggests that the PID + IFB algorithm may allow for lower target glucose selection and improved overall glycemic control.
Collapse
Affiliation(s)
- Jessica L Ruiz
- Department of Pediatrics, Yale University School of Medicine, New Haven, Connecticut 06520-8064, USA
| | | | | | | | | | | | | | | |
Collapse
|
37
|
Abu-Rmileh A, Garcia-Gabin W. Wiener sliding-mode control for artificial pancreas: a new nonlinear approach to glucose regulation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2012; 107:327-340. [PMID: 22560247 DOI: 10.1016/j.cmpb.2012.03.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2011] [Revised: 10/08/2011] [Accepted: 03/06/2012] [Indexed: 05/31/2023]
Abstract
Type 1 diabetic patients need insulin therapy to keep their blood glucose close to normal. In this paper an attempt is made to show how nonlinear control-oriented model may be used to improve the performance of closed-loop control of blood glucose in diabetic patients. The nonlinear Wiener model is used as a novel modeling approach to be applied to the glucose control problem. The identified Wiener model is used in the design of a robust nonlinear sliding mode control strategy. Two configurations of the nonlinear controller are tested and compared to a controller designed with a linear model. The controllers are designed in a Smith predictor structure to reduce the effect of system time delay. To improve the meal compensation features, the controllers are provided with a simple feedforward controller to inject an insulin bolus at meal time. Different simulation scenarios have been used to evaluate the proposed controllers. The obtained results show that the new approach outperforms the linear control scheme, and regulates the glucose level within safe limits in the presence of measurement and modeling errors, meal uncertainty and patient variations.
Collapse
Affiliation(s)
- Amjad Abu-Rmileh
- Research Group on Statistics, Econometrics and Health (GRECS), University of Girona, 17071 Girona, Spain.
| | | |
Collapse
|
38
|
Liu SW, Huang HP, Lin CH, Chien IL. A Hybrid Neural Network Model Predictive Control with Zone Penalty Weights for Type 1 Diabetes Mellitus. Ind Eng Chem Res 2012. [DOI: 10.1021/ie202308w] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Shih-Wei Liu
- Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Hsiao-Ping Huang
- Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Chia-Hung Lin
- Division of Endocrinology and
Metabolism, Department of Internal Medicine, Chang Gung Memorial Hospital, Tao-Yuan 33305, Taiwan
| | - I-Lung Chien
- Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan
| |
Collapse
|
39
|
Affiliation(s)
- Claudio Cobelli
- Department of Information Engineering, University of Padova, Padova, Italy.
| | | | | |
Collapse
|