1
|
da Rocha LS, de Oliveira DF, de Lima CLV, do Nascimento TG, de Freitas JD, de Freitas JMD, Porto ICCDM. Effect of propolis added to single-bottle adhesives on water permeation through the hybrid layer. Eur J Oral Sci 2024:e13023. [PMID: 39390713 DOI: 10.1111/eos.13023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Accepted: 09/20/2024] [Indexed: 10/12/2024]
Abstract
Water treeing and water droplets are observed within adhesive layers and on the hybridized surface after bonding sound dentin using single-bottle etch-and-rinse adhesives, indicating permeability of the hybrid layer to water. The aim of this study was to assess the efficacy of dentin sealing by adhesives containing propolis by quantifying the area of water transudation from dentinal tubules after dentin hybridization. Brazilian red propolis was added to experimental adhesive and Single Bond (3M/ESPE) adhesive; experimental adhesive and Single Bond without propolis were used as controls. Under simulated pulp pressure, two layers of adhesive were applied to etched human dentin discs. Three minutes after light-curing, the hybridized dentin surface was replicated, and epoxy resin replicas were created to obtain scanning electron microscope images. Data were evaluated using ANOVA and Tukey's test. Single Bond containing propolis significantly decreased water permeation through the hybrid layer compared with the control group. Three minutes after polymerization, the experimental adhesive without propolis had formed a permeable hybrid layer. The addition of Brazilian red propolis significantly reduced surface water on hybridized dentin in a concentration-dependent manner. Two-step etch-and-rinse adhesives containing propolis were effective in reducing water permeation through the hybridized dentin surface.
Collapse
|
2
|
Checchi V, Generali L, Corciolani L, Breschi L, Mazzitelli C, Maravic T. Wear and roughness analysis of two highly filled flowable composites. Odontology 2024:10.1007/s10266-024-01013-0. [PMID: 39373833 DOI: 10.1007/s10266-024-01013-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Accepted: 09/26/2024] [Indexed: 10/08/2024]
Abstract
This in vitro study aimed to evaluate surface roughness and wear of highly filled flowables and traditional packable composites. Additionally, the effect of polymerization time on these parameters was evaluated. Two flowable higly filled composites (CMf-Clearfil Majesty ES flow-low viscosity, Kuraray and GUf-Gaenial Universal Injectable, GC) and two packable composites (CM-Clearfil Majesty ES-2, Kuraray and GU-Gaenial A'CHORD, GC) were used to create 160 specimens (n = 40;8 × 6 × 4mm). For each tested material, two subgroups were considered according to the polymerization time (n = 20): 10 s or 80 s. After setting, the specimens were subjected to chewing simulations (240.000 cycles, 20N), and wear was measured by the laser integrated in the chewing simulator. The surface roughness was measured using a rugosimeter, before and after chewing cycles. Two representative specimens per group were observed under scanning electron microscope (SEM). Data were collected and statistically analyzed (p < 0.05). Wear analysis highlighted statistically significant differences between the groups: CMf10-CMf80 (p = 0.000), CMf10-CM10 (p = 0.019), CMf10-GUf10 (p = 0.002), CM10-CM80 (p = 0.000), CM80-GUf80 (p = 0.02), GUf10-GUf80 (p = 0.000), GUf10-GU10 (p = 0.043) and GU10-GU80 (p = 0.013). Statistically significant differences in surface roughness were highlighted between the groups: CMf10-CMf80 (p = 0.038), CMf80-CM80 (p = 0.019), CMf80-GU80 (p = 0.010), CM80-GUf80 (p = 0.34) and GUf80-GU80 (p = 0.003). Surface roughness and wear of highly filled flowable composites were comparable to that of traditional paste composites. Furthermore, a longer curing time leads to an improvement in the mechanical properties of the composites. Highly filled flowables can be a valid alternative to paste composites in occlusal areas due to its similar surface roughness and wear values, especially when overcured.
Collapse
Affiliation(s)
- Vittorio Checchi
- Department of Surgery, Medicine, Dentistry and Morphological Sciences With Transplant Surgery, Oncology and Regenerative Medicine Relevance, University of Modena and Reggio Emilia, Modena, Italy.
| | - Luigi Generali
- Department of Surgery, Medicine, Dentistry and Morphological Sciences With Transplant Surgery, Oncology and Regenerative Medicine Relevance, University of Modena and Reggio Emilia, Modena, Italy
| | - Laura Corciolani
- Department of Surgery, Medicine, Dentistry and Morphological Sciences With Transplant Surgery, Oncology and Regenerative Medicine Relevance, University of Modena and Reggio Emilia, Modena, Italy
| | - Lorenzo Breschi
- Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Claudia Mazzitelli
- Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Tatjana Maravic
- Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| |
Collapse
|
3
|
Lucena FSD, Logan M, Lewis S, Deatherage N, Furuse AY, Pfeifer CS. A novel low shrinkage dimethacrylate monomer as an alternative to BisGMA for adhesive and resin-based composite applications. Braz Oral Res 2024; 38:e097. [PMID: 39356904 PMCID: PMC11441822 DOI: 10.1590/1807-3107bor-2024.vol38.0097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Accepted: 06/24/2024] [Indexed: 10/04/2024] Open
Abstract
The aim of this study was to develop a mixture of dimethacrylate isomers (PG6EMA) as a potential monomer for dental adhesives and composites. PG6EMA was synthesized de novo and characterized in the presence of ethanol (3%, 6% or 9%). BisGMA/TEGDMA (BTEG, 50/50 wt.%) was used as the resin control. Composites were formulated with 60 wt.% of either PG6EMA or BisGMA (40 wt.% TEGDMA and 70 wt.% filler). DMPA (0.2 wt.%) and DPI-PF6 (0.4 wt.%) were added as photoinitiators, irradiated with a mercury arc lamp (320-500 nm, 500 mW/cm2; Acticure). All materials were tested for polymerization kinetics (near-infrared), viscosity (η) and storage modulus (G', oscillatory rheometry). The composites were further characterized for water sorption/solubility, wet/dry flexural strength/modulus and polymerization stress. Data were analyzed with one-way ANOVA/Tukey's test (α = 0.05). The PG6EMA resins showed lower rates of polymerization compared with BTEG (p = 0.001) but high degrees of conversion (p = 0.002). Solvent concentration did not affect RPMAX but the 6% and 9% mixtures showed higher final DC, likely due to reduced viscosity. PG6EMA had much higher viscosity than BTEG (p <0.001) and lower G' (p = 0.003). Composites modified with PG6EMA have slower polymerization rates (p = 0.001) but higher final DC (p = 0.04) than the control. PG6EMA/TEGDMA showed lower dry/wet flexural strength and comparable dry modulus. The PG6EMA/TEGDMA composite showed a 18.4% polymerization stress reduction compared to the BTEG composite. Both base monomers had similar WS/SL and G'. Within its limitations, this study demonstrated that the newly synthesized PG6EMA was a viable alternative to BisGMA in dental composites.
Collapse
Affiliation(s)
- Fernanda Sandes de Lucena
- Universidade de São Paulo - USP, Bauru School of Dentistry, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru, SP, Brazil
| | - Matthew Logan
- Oregon Health & Science University, School of Dentistry, Department of Restorative Dentistry, Portland, OR, EUA
| | - Steven Lewis
- Oregon Health & Science University, School of Dentistry, Department of Restorative Dentistry, Portland, OR, EUA
| | - Neil Deatherage
- Oregon Health & Science University, School of Dentistry, Department of Restorative Dentistry, Portland, OR, EUA
| | - Adilson Yoshio Furuse
- Universidade de São Paulo - USP, Bauru School of Dentistry, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru, SP, Brazil
| | - Carmem Silvia Pfeifer
- Oregon Health & Science University, School of Dentistry, Department of Restorative Dentistry, Portland, OR, EUA
| |
Collapse
|
4
|
Wei F, Bai T, Chen H, Sun G, Chen X, Zhu S. Light-curable urushiol enhanced bisphenol A glycidyl dimethacrylate dentin bonding agent. J Dent 2024; 148:105261. [PMID: 39047891 DOI: 10.1016/j.jdent.2024.105261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 07/07/2024] [Accepted: 07/22/2024] [Indexed: 07/27/2024] Open
Abstract
OBJECTIVES The low durability of composite resin restorations can be attributed to the degradation of the resin dentin bonding interface. Owing to the presence of hydrophilic components in the adhesive, the integrity of the resin dentin bonding interface is easily compromised, which, in turn, leads to a reduction in bond strength. The hydrophilic nature of the adhesive leads to water sorption, phase separation, and leaching of the resin component. Therefore, hydrophobic adhesives could effectively be used to stabilize the integrity and durability of the resin dentin bonding interface. METHODS We synthesized a novel hydrophobic dentin adhesive by partially replacing bisphenol A glycidyl dimethacrylate (Bis-GMA) with a light-curable urushiol monomer. The properties of the produced adhesive, including the degree of conversion, viscosity, contact angle, water sorption/solubility, and mechanical strength, were comprehensively examined and compared to those of the commercially adhesive Adper Single Bond2 as a positive control. The adhesive properties were determined using microtensile bond strength measurements, laser confocal microscopy, scanning electron microscopy observations, and nanoleakage tests. Finally, the novel adhesive was subjected to biocompatibility testing to determine its potential cytotoxicity. RESULTS At a light-curable urushiol content of 20 %, the synthesized adhesive exhibited high degrees of conversion and hydrophobicity, low cytotoxicity, good mechanical properties, and outstanding adhesive strength. CONCLUSIONS The introduction of the light-curable urushiol into dentin adhesives can significantly enhance their hydrophobic, mechanical, and bonding properties, demonstrating potential to significantly improve restoration longevity. CLINICAL SIGNIFICANCE The integration of light-curable urushiol has endowed the experimental adhesives with several enhanced functionalities. These notable benefits underscore the suitability of this monomer for expanded applications in clinical practice.
Collapse
Affiliation(s)
- Fei Wei
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, Changchun, Jilin Province, PR China
| | - Tingting Bai
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, Changchun, Jilin Province, PR China
| | - Huan Chen
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, Changchun, Jilin Province, PR China
| | - Guangdi Sun
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, Changchun, Jilin Province, PR China
| | - Xue Chen
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, Changchun, Jilin Province, PR China
| | - Song Zhu
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, Changchun, Jilin Province, PR China.
| |
Collapse
|
5
|
Meskher H, Sharifianjazi F, Tavamaishvili K, Irandoost M, Nejadkoorki D, Makvandi P. Limitations, challenges and prospective solutions for bioactive glasses-based nanocomposites for dental applications: A critical review. J Dent 2024; 150:105331. [PMID: 39216818 DOI: 10.1016/j.jdent.2024.105331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Revised: 08/12/2024] [Accepted: 08/28/2024] [Indexed: 09/04/2024] Open
Abstract
Several nanomaterials have been recently used to overcome various challenges in the dental domain. Bioactive glasses, a class of bioceramics, with their outstanding properties including but not limited to their strong biocompatibility, antibacterial characteristics, and bioactivity inside the body's internal milieu have made them valuable biomaterials in a variety of dental domains. The utilization of nanomaterials has improved the performance of teeth, and the incorporation of bioactive glasses has the field of dentistry at an unsurpassed level in different categories such as esthetic and restorative dentistry, periodontics and dental implants, orthodontics, and endodontics. The current study discusses the most recent developments of the bioactive glasses' creation and implementation for dental applications, as well as the challenges and opportunities still facing the field. This work provides an overview of the current obstacles and potential future prospects for bioactive glasses-based nanocomposites to improve their dental uses. It also emphasizes the great potential synergistic effects of bioactive glasses used with other nanomaterials for dental applications.
Collapse
Affiliation(s)
- Hicham Meskher
- Division of Process Engineering, College of Science and Technology, Chadli Bendjedid University, 36000, Algeria
| | - Fariborz Sharifianjazi
- Center for Advanced Materials and Structures, School of Science and Technology, The University of Georgia, Tbilisi, Georgia.
| | - Ketevan Tavamaishvili
- Georgian American University, School of Medicine, 10 Merab Aleksidze Str, Tbilisi 0160, Georgia
| | - Maryam Irandoost
- Department of Materials and Metallurgical Engineering, Amirkabir University of Technology, Tehran, Iran
| | | | - Pooyan Makvandi
- The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, Quzhou, Zhejiang 324000, China; University Centre for Research & Development, Chandigarh University, Mohali, Punjab, 140413, India; Centre of Research Impact and Outcome, Chitkara UniversityInstitute of Engineering and Technology, Chitkara University, Rajpura, Punjab 140401, India.
| |
Collapse
|
6
|
Osorio-Vélez LS, Serna-Ceballos JD, Latorre F, Ardila CM. A Conservative Approach to Ceramic Laminates in the Anterior Region: A Clinical Report. Cureus 2024; 16:e68137. [PMID: 39347218 PMCID: PMC11438498 DOI: 10.7759/cureus.68137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/28/2024] [Indexed: 10/01/2024] Open
Abstract
This clinical report presents a conservative approach to restoring aesthetic function in anterior maxillary teeth using digital dental technologies. A 40-year-old female patient sought treatment to enhance the aesthetics of her anterior maxillary teeth. The clinical examination revealed wear on the incisal surfaces and gingival asymmetry. Utilizing a digital workflow, intraoral and extraoral data were acquired through clinical photographs and an intraoral scanner. The patient's restorative needs were assessed using the 3Shape Smile Design system (3Shape, Copenhagen, Denmark). Minimal-thickness ceramic restorations were designed and fabricated using Computer-Aided Design-Computer-Aided Manufacturing (CAD-CAM) technologies. Lithium disilicate was selected for its strong mechanical properties and adhesive capabilities. The restorations were then placed using an adhesive cementation protocol under magnification. Digital technologies facilitated precise diagnosis, planning, and execution of the treatment. The ceramic restorations provided excellent aesthetic outcomes, aligning with the patient's expectations. The minimal thickness of the restorations ensured the preservation of natural tooth structure while maintaining structural integrity and adhesion performance. This case underscores the advantages of a digital workflow in achieving optimal restorative outcomes. The digital dental workflow demonstrated in this case report provides a reliable, efficient, and patient-centric approach to minimal thickness restorations, highlighting the potential for future advancements in restorative dentistry.
Collapse
Affiliation(s)
- Laura S Osorio-Vélez
- Prosthodontics Postgraduate Program, Faculty of Dentistry, Universidad de Antioquia, Medellín, COL
| | - Juan D Serna-Ceballos
- Prosthodontics Postgraduate Program, Faculty of Dentistry, Universidad de Antioquia, Medellín, COL
| | - Federico Latorre
- Prosthodontics Postgraduate Program, Faculty of Dentistry, Universidad de Antioquia, Medellín, COL
| | - Carlos M Ardila
- Biomedical Stomatology Research Group, Faculty of Dentistry, Universidad de Antioquia, Medellín, COL
| |
Collapse
|
7
|
Lehmann A, Nijakowski K, Jankowski J, Donnermeyer D, Ramos JC, Drobac M, Martins JFB, Hatipoğlu Ö, Omarova B, Javed MQ, Alharkan HM, Bekjanova O, Wyzga S, Alkhawas MBAM, Kudenga R, Surdacka A. Clinical Difficulties Related to Direct Composite Restorations: A Multinational Survey. Int Dent J 2024:S0020-6539(24)00164-3. [PMID: 39048490 DOI: 10.1016/j.identj.2024.06.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 06/14/2024] [Accepted: 06/18/2024] [Indexed: 07/27/2024] Open
Abstract
AIMS Composite materials are widely used in dentistry for direct tooth restorations. However, they are highly sensitive to the working technique employed during the restorative procedure. Even minor procedural errors can have a significant impact on the quality including the longevity of the restoration. Hence the aim of this study was to determine the material preferences and analyse the clinical problems associated with direct composite restorations in a cohort of dentists. METHODS A 20-item online questionnaire was created in English and administered 1830 general dentists and specialists in 13 countries. The first section of the questionnaire included four questions to elicit demographic data, and the second section comprised 16 questions focused on material preferences for conservative restorations, durability of composite restorations, and the most challenging stages the dentists faced during the composite restorative procedures. RESULTS Respondents decided most often to use composite materials for the tooth restorations (OR 997.4, 95% CI 233.8-4254.8, P value <.001). Most respondents indicated that the durability of composite restorations was approximately 7 to 10 years (41.5%). Among the factors affecting durability, maintenance of a dry cavity was the most often reported reason (47.1%) and the foremost challenge faced by dentists (61.0%) during the composite restorative procedures. CONCLUSIONS Our study confirmed that resin-based composites are the most popular material for direct restoration in many countries. Although working with this material is difficult and involves multiple steps, maintaining a dry cavity during bonding, and material application may affect the therapeutic success and durability of these restorations. Clinicians need to be attentive to this issue and be prepared to adapt their decision-making and consider opting for alternative restorative materials, if appropriate.
Collapse
Affiliation(s)
- Anna Lehmann
- Department of Conservative Dentistry and Endodontics, Poznan University of Medical Sciences, Poznan, Poland
| | - Kacper Nijakowski
- Department of Conservative Dentistry and Endodontics, Poznan University of Medical Sciences, Poznan, Poland.
| | - Jakub Jankowski
- Department of Conservative Dentistry and Endodontics, Poznan University of Medical Sciences, Poznan, Poland
| | - David Donnermeyer
- Department of Periodontology and Operative Dentistry, University Münster, Münster, Germany
| | - João Carlos Ramos
- Center for Innovation and Research in Oral Sciences (CIROS) and Institute of Operative Dentistry, Faculty of Medicine, University of Coimbra, Coimbra, Portugal
| | - Milan Drobac
- Department of Dental Medicine, Faculty of Medicine, University of Novi Sad, Novi Sad, Serbia
| | - João Filipe Brochado Martins
- Departments of Endodontology Academic Centre for Dentistry Amsterdam, University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Ömer Hatipoğlu
- Department of Restorative Dentistry, Niğde Ömer Halisdemir University, Niğde, Turkiye
| | - Bakhyt Omarova
- Department of Therapeutic Dentistry, Kazakh National Medical University by S.D. Asfendiyarov, Almaty, Kazakhstan
| | - Muhammad Qasim Javed
- Department of Conservative Dental Sciences, College of Dentistry, Qassim University, Buraydah, Qassim, Saudi Arabia
| | - Hamad Mohammad Alharkan
- Department of Conservative Dental Sciences, College of Dentistry, Qassim University, Buraydah, Qassim, Saudi Arabia
| | - Olga Bekjanova
- Department of Faculty Therapeutic Dentistry, Tashkent State Dental Institute, Tashkent, Uzbekistan
| | - Sylvia Wyzga
- Department of Conservative Dentistry and Endodontics, Poznan University of Medical Sciences, Poznan, Poland
| | | | - Rutendo Kudenga
- Department of Odontology, University of Pretoria, Riviera, Pretoria, Republic of South Africa
| | - Anna Surdacka
- Department of Conservative Dentistry and Endodontics, Poznan University of Medical Sciences, Poznan, Poland
| |
Collapse
|
8
|
Ñaupari-Villasante R, de Freitas A, Hass V, Matos TP, Parreiras SO, Reis A, Gutiérrez MF, Loguercio AD. Prolonged polymerization of a universal adhesive in non-carious cervical lesions: 36-month double-blind randomized clinical trial. J Dent 2024; 142:104823. [PMID: 38145806 DOI: 10.1016/j.jdent.2023.104823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Revised: 12/18/2023] [Accepted: 12/22/2023] [Indexed: 12/27/2023] Open
Abstract
OBJECTIVE To evaluate the effect of prolonged (P) polymerization time of a universal adhesive system applied in etch-and-rinse (ER) or self-etch (SE) strategies on the clinical performance of restorations in non-carious cervical lesions (NCCLs), after 36 months of clinical service. METHODS A total of 140 restorations were randomly placed in 35 subjects according to the polymerization time groups: ER (10 s); ER-P (40 s); SE (10 s); and SE-P (40 s) at 1,200 mW/cm2. Composite resin was placed incrementally. The restorations were evaluated immediately and after 6, 12, 18, and 36 months using the FDI criteria. Data were analyzed using the Kaplan-Meier survival test for retention loss, and the Kruskal-Wallis' test for secondary outcomes (α = 0.05). RESULTS After 36 months, 19 restorations were lost: ER 6, ER-P 2, SE 9, SE-P 2. The retention rates were 82.3% for ER; 94.1 % for ER-P; 73.5 % for SE; and 94.1 % for SE-P, with a significant difference between ER vs. ER-P and SE vs. SE-P, as well as ER vs. SE-P and ER-P vs. SE (p < 0.0001). Minor defects were observed in 18 restorations for the marginal staining criteria: ER 5, ER-P 2, SE 8, SE-P 3; and in 33 restorations for the marginal adaptation criteria: ER 11, ER-P 4, SE 12, and SE-P 6 (p > 0.05). No restorations showed recurrence of caries or postoperative sensitivity. CONCLUSIONS A prolonged polymerization time of 40 s improves the clinical performance of the universal adhesive for both adhesive strategies evaluated, even after 36 months. CLINICAL SIGNIFICANCE Prolonging the polymerization time of a universal adhesive from 10 to 40 s has been shown to improve its clinical performance when used in NCCLs.
Collapse
Affiliation(s)
- Romina Ñaupari-Villasante
- Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | - André de Freitas
- Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | - Viviane Hass
- School of Dentistry, Oral and Craniofacial Sciences, University of Missouri-Kansas City, Kansas City, MO, USA
| | - Thalita P Matos
- Department of Restorative Dentistry, School of Dentistry, Tuiuti University of Paraná, Curitiba, PR, Brazil
| | - Sibelli O Parreiras
- Department of Restorative Dentistry, State University of Northern Paraná, Jacarezinho, PR, Brazil
| | - Alessandra Reis
- Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | - Mario F Gutiérrez
- Universidad de los Andes, Chile. Facultad de Odontología, Santiago, Chile; Department of Restorative Dentistry, Faculty of Dentistry, University of Chile, Santiago, Chile.
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| |
Collapse
|
9
|
Algamaiah H, Yang J, Alayed A, Alshabib A, Alshehri A, Watts DC. Temperature rise in photopolymerized adhesively-bonded resin composite: A thermography study. Dent Mater 2024; 40:458-465. [PMID: 38129192 DOI: 10.1016/j.dental.2023.12.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Revised: 12/10/2023] [Accepted: 12/10/2023] [Indexed: 12/23/2023]
Abstract
OBJECTIVES To assess visually and quantitatively the contributions of the adhesive layer photopolymerization and the subsequent resin composite increment to spatio-temporal maps of temperature at five different cavity locations, subjected to two irradiance curing protocols: standard and ultra-high. METHODS Caries-free molars were used to obtain 40, 2 mm thick dentin slices, randomly assigned to groups (n = 5). These slices were incorporated within 3D-printed model cavites, 4 mm deep, restored with Adhese® Universal bonding agent and 2 mm thick Tetric® Powerfill resin composite, and photocured sequentially, as follows: G1: control-empty cavity; G2: adhesive layer; G3 composite layer with no adhesive; and G4 composite layer with adhesive. The main four groups were subdivided based on two curing protocols, exposed either to standard 10 s (1.2 W/cm2) or Ultra high 3 s (3 W/cm2) irradiance modes using a Bluephase PowerCure LCU. Temperature maps were obtained, via a thermal imaging camera, and numerically analyzed at 5 locations. The data were analyzed using two-way ANOVA followed by multiple one-way ANOVA, independent t-tests and Tukey post-hoc tests (α = 0.05). Tmax, ΔT, Tint (integrated area under the curve) and time-to-reach-maximum-temperature were evaluated. RESULTS Two-way ANOVA showed that there was no significant interaction between light-curing time and location on the measured parameters (p > 0.05), except for the time-to-reach-maximum-temperature (p < 0.05). Curing the adhesive layer alone with the 10 s protocol resulted in a significantly increased pulpal roof temperature compared to 3 s cure (p < 0.05). Independent T-tests between G3 and G4, between 3 s and 10 s, confirmed that the adhesive agent caused no significant increases (p > 0.05) on the measured parameters. The ultra-high light-curing protocol significantly increased ΔT in composite compared to 10 s curing (p < 0.05). SIGNIFICANCE When the adhesive layer was photocured alone in a cavity, with a 2 mm thick dentin floor, the exothermal release of energy resulted in higher temperatures with a 10 s curing protocol, compared to a 3 s high irradiance. But when subsequently photocuring a 2 mm layer of composite, the resultant temperatures generated at pulpal roof location from the two curing protocols were similar and therefore there was no increased hazard to the dental pulp from the immediately prior adhesive photopolymerization, cured via the ultra-high irradiation protocol.
Collapse
Affiliation(s)
- Hamad Algamaiah
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia.
| | - Jiawei Yang
- Department of prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, China; National Clinical Research Center for Oral Diseases, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Abdulaziz Alayed
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia; Biomaterials Science, Division of Dentistry, School of Medical Sciences, University of Manchester, UK
| | - Abdulrahman Alshabib
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia
| | - Abdullah Alshehri
- Department of Conservative Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Alkharj 11942, Saudi Arabia
| | - David C Watts
- Biomaterials Science, Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Photon Science Institute, University of Manchester, UK.
| |
Collapse
|
10
|
Alshabib A, AlDosary K, Algamaiah H. A comprehensive review of resin luting agents: Bonding mechanisms and polymerisation reactions. Saudi Dent J 2024; 36:234-239. [PMID: 38420009 PMCID: PMC10897588 DOI: 10.1016/j.sdentj.2023.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 11/06/2023] [Accepted: 11/07/2023] [Indexed: 03/02/2024] Open
Abstract
The field of dentistry is constantly evolving and increasingly embracing minimally invasive approaches. One such approach, which is bonding to the tooth structure, particularly enamel, has been shown to offer the most predictable outcomes. However, there are instances where significant tooth loss may limit treatment options for a restorative dentist. In these scenarios, indirect restoration might be the preferred treatment option. This literature review provides a comprehensive examination of the currently available resin luting agents and their bonding requirements. It provides valuable insights for dental professionals seeking an in-depth understanding of the current state of the field and the future prospects of dental adhesion.
Collapse
Affiliation(s)
- Abdulrahman Alshabib
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Khalid AlDosary
- Dental Department, King Abdulaziz University Hospital, King Saud University, Riyadh, Saudi Arabia
| | - Hamad Algamaiah
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
11
|
Taghvaei N, Ghavami-Lahiji M, Evazalipour M, Tayefeh Davalloo R, Zamani E. Ion release, biocompatibility, and bioactivity of resin-modified calcium hydroxide cavity liners. BMC Oral Health 2023; 23:1034. [PMID: 38129851 PMCID: PMC10740215 DOI: 10.1186/s12903-023-03723-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Accepted: 11/28/2023] [Indexed: 12/23/2023] Open
Abstract
BACKGROUND The placement of liners near the pulp area is essential for therapeutic effects and maintaining pulp health while stimulating the formation of tertiary dentin. This in vitro study aimed to evaluate the calcium release, pH, biocompatibility, solubility, and bioactivity of three resin-modified calcium hydroxide cavity liners. METHODS The disc specimens of each cavity liner were prepared using polyethylene molds of 7 mm in diameter and 2 mm in height (n = 10). Three light-cure liners evaluated include Ultra-Blend Plus (UB), Base-it (BI), and Master Dent (MD). The samples were then immersed in flasks containing 10 mL of distilled water. Calcium ion release, pH, and solubility were evaluated in two weeks of incubation. The cytotoxicity of extracts adjacent to the specimens was evaluated by MTT assay using NIH/3T3 cells after 1, 3, and 7 days of incubation. The ability to induce the nucleation of calcium phosphates (CaPs) after 28-day immersion in a simulated body fluid was investigated by SEM-EDX analysis. Statistical analysis was performed using ANOVA, Kruskal-Wallis, and repeated measures tests at the significant level of 0.05. RESULTS There was a significant difference in the release of calcium ions among the three liners investigated on days 1, 7, and 14 (p < 0.05). UB liners exhibited a significantly higher amount of calcium release than the other two liners, followed by BI, and MD. On day 1, there was no significant difference in the average pH among the three liners. However, after day 7, the MD liner showed a significant decrease in pH compared to the other two liners. BI liner demonstrated the highest level of biocompatibility, followed by the MD and UB liners. UB showed a high calcium release, solubility with no alkalizing activity, and the formation of more mature Ca-rich apatite deposits than the other two liners. CONCLUSION Based on the results of this study, the cavity liner material's performance is material dependent. It can impact ion release, biocompatibility, and bioactivity which are important factors to consider in clinical practice. Further studies are needed to investigate the long-term effects of different liner materials on oral tissues.
Collapse
Affiliation(s)
- Nastaran Taghvaei
- Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Mehrsima Ghavami-Lahiji
- Department of Restorative Dentistry, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran.
| | - Mehdi Evazalipour
- Department of Pharmaceutical Biotechnology, School of Pharmacy, Guilan University of Medical Sciences, Rasht, Iran
| | - Reza Tayefeh Davalloo
- Department of Restorative Dentistry, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Ehsan Zamani
- Department of Pharmacology and Toxicology, School of Pharmacy, Guilan University of Medical Sciences, Rasht, Iran
| |
Collapse
|
12
|
Josic U, D'Alessandro C, Miletic V, Maravic T, Mazzitelli C, Jacimovic J, Sorrentino R, Zarone F, Mancuso E, Delgado AH, Breschi L, Mazzoni A. Clinical longevity of direct and indirect posterior resin composite restorations: An updated systematic review and meta-analysis. Dent Mater 2023; 39:1085-1094. [PMID: 37827872 DOI: 10.1016/j.dental.2023.10.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 09/21/2023] [Accepted: 10/05/2023] [Indexed: 10/14/2023]
Abstract
OBJECTIVES To answer the PICO(S) question: Is there a difference in clinical longevity between direct and indirect resin composite restorations placed on permanent posterior teeth? DATA Randomized controlled clinical trials (RCTs) investigating direct and indirect resin composite restorations in posterior permanent teeth were considered. SOURCES Several electronic databases were searched, with no language or date restrictions. The revised Cochrane Collaboration's tool for assessing risk of bias (RoB-2) was used to analyze the studies; meta-analyses were run and the certainty of evidence was assessed by the GRADE tool. A subgroup meta-analysis was performed for resin composite restorations placed on posterior worn dentition. STUDY SELECTION Twenty-three articles were included in qualitative synthesis, while 8 studies were used for meta-analyses. According to the RoB-2 tool, 5 studies were ranked as "low risk", 7 had "some concerns", while 11 papers were rated as "high risk" of bias. There were no statistically significant differences in short-term (p = 0.27; RR=1.54, 95% CI [0.72, 3.33]), medium-term (p = 0.27; RR=1.87, 95% CI [0.61, 5.72]) and long-term longevity (p = 0.86; RR=0.95, 95% CI [0.57, 1.59]). The choice of restorative technique had no influence on short-term survival of resin composite restorations placed on worn dentition (p = 0.13; RR=0.46, 95% CI [0.17, 1.25]). The certainty of evidence was rated as "very low". CONCLUSIONS Direct and indirect resin composite restorations may show similar clinical longevity in posterior region, regardless of the observation period or substrate (wear-affected and non-affected dentition). The very low quality of evidence suggests that more long-term RCTs are needed to confirm our results.
Collapse
Affiliation(s)
- Uros Josic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Carlo D'Alessandro
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Vesna Miletic
- Sydney Dental School, Faculty of Medicine and Health, University of Sydney, Sydney 2145, Australia
| | - Tatjana Maravic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Claudia Mazzitelli
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Jelena Jacimovic
- Central Library, School of Dental Medicine, University of Belgrade, Serbia
| | - Roberto Sorrentino
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Italy
| | - Fernando Zarone
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Italy
| | - Edoardo Mancuso
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - António Hs Delgado
- Egas Moniz Center for Interdisciplinary Research (CiiEM), Monte de Caparica, Almada 2829-511, Portugal; Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, London, UK
| | - Lorenzo Breschi
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy.
| | - Annalisa Mazzoni
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| |
Collapse
|
13
|
Tang K, Wang F, Dai SQ, Yang ZY, Duan LY, Luo ML, Tay FR, Niu LN, Zhou W, Chen JH. Enhanced Bonding to Caries-Affected Dentin Using an Isocyanate-Based Primer. J Dent Res 2023; 102:1444-1451. [PMID: 37950512 DOI: 10.1177/00220345231199416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2023] Open
Abstract
Dental caries is the most common oral disease and the most common cause of resin restorations. In minimally invasive dentistry, the principle behind cavity preparation is to remove external caries-infected dentin (CID) and preserve internal caries-affected dentin (CAD) and sound dentin (SD). The cavity floor is mainly composed of CAD, but the poor bonding performance of CAD has become a widespread concern. This study evaluated the performance of a new collagen-reactive monomer (ITCM) used as a primer to improve the bonding performance of CAD. The experimental specimens were grouped as follows: SD, CAD, and ITCM-pretreated CAD (CAD-ITCM). Dentin slices were obtained for attenuated total reflectance-Fourier transform infrared (ATR-FTIR) analysis. The bonded samples were subjected to microtensile bond strength analysis after 24 h of water storage or aging by thermocycling, and the bonding interface quality was evaluated by nanoleakage assessment, interfacial nanoindentation testing, and in situ zymography. Cytotoxicity experiments with ITCM were performed. ATR-FTIR showed that the isocyanate groups in ITCM can covalently bind and form hydrogen bonds with the collagen in CAD to mediate chemical bonding. ITCM pretreatment significantly improved the bond strength of CAD (P < 0.05), reduced interfacial nanoleakage, improved the sealing of the bonding interface, enhanced the homogeneity of the hybrid layer, and inhibited matrix metalloproteinase activity. In addition, ITCM presented acceptable biocompatibility for dental restorative application. Taken together, this study reported the application of ITCM to induce collagen-based chemical bonding in the CAD bonding system, which fills the gap in strategies to improve the bonding performance of CAD immediately and after aging and has important clinical application prospects.
Collapse
Affiliation(s)
- K Tang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - F Wang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - S Q Dai
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Z Y Yang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - L Y Duan
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - M L Luo
- Institute of Stomatology & Oral Maxilla Facial Key Laboratory, The First Medical Center, Chinese PLA General Hospital & Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Xi'an, Beijing, China
| | - F R Tay
- The Dental College of Georgia, Augusta University, Augusta, GA, USA
| | - L N Niu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - W Zhou
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - J H Chen
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| |
Collapse
|
14
|
Fidan M, Yağci Ö. Do universal adhesive systems affect color coordinates and color change of single-shade resin composites compared with a multi-shade composite? Dent Mater J 2023; 42:886-893. [PMID: 37914230 DOI: 10.4012/dmj.2023-120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2023]
Abstract
The objective of the study was the impact of universal adhesives on color coordinates and color change of single-shade resin composites compared with a multi-shade composite after thermocycling. Five resin composites (Filtek Z250, Omnichroma, Vittra APS Unique, Zenchroma, and Charisma Diamond One) were used. The composites were randomly divided into three subgroups: two universal adhesive groups (Single Bond and Gluma Bond) and one control group (n=10). Color measurements were performed initially and after 10,000 thermocycling. Color change (ΔE00) values were calculated using the CIEDE2000 formula. The two-way variance analysis was used (p<0.05). The lowest and highest ΔE00 were exhibited in the Filtek Z250 and Charisma Diamond One (p<0.001, p<0.001, respectively). The highest ΔE00 was exhibited in the Gluma Bond (p<0.001). An adhesive system may adversely affect the color change of resin composite materials. L and a values of resin composites decreased, and the b values increased after thermocycling.
Collapse
Affiliation(s)
- Muhammet Fidan
- Department of Restorative Dentistry, Faculty of Dentistry, Usak University
| | - Özhan Yağci
- Department of Restorative Dentistry, Faculty of Dentistry, Usak University
| |
Collapse
|
15
|
Ferreira MN, Neves Dos Santos M, Fernandes I, Marto CM, Laranjo M, Silva D, Serro AP, Carrilho E, Botelho MF, Azul AM, Delgado AH. Effect of varying functional monomers in experimental self-adhesive composites: polymerization kinetics, cell metabolism influence and sealing ability. Biomed Mater 2023; 18:065014. [PMID: 37738988 DOI: 10.1088/1748-605x/acfc8d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 09/22/2023] [Indexed: 09/24/2023]
Abstract
The aim was to evaluate the effects of adding different functional monomers to experimental self-adhesive composites (SACs) on polymerization kinetics, cell metabolic activity, and sealing ability. SACs were formulated using urethane dimethacrylate as the base monomer and triethylene glycol dimethacrylate. Additionally, 10 wt.% of distinct functional monomers were added - 10-methacryloyloxydecyl dihydrogen phosphate, glycerol phosphate dimethacrylate (GPDM), 2-hydroxyethyl methacrylate (HEMA) or hydroxyethyl acrylamide (HEAA). ATR-FTIR was used to determine real-time polymerization kinetics (20 min,n= 3). The final extrapolated conversion and polymerization rates were determined (DC,max;Rp,max). TheDC,maxvalues were employed to calculate volumetric shrinkage. The MTT assay was performed on MDPC-23 cells using disc extracts at different concentrations (n= 8). Class V cavities were prepared in 60 sound human molars, assigned to six groups (n= 10), depending on the composite used and aging type (T0 or TC, if thermocycled for 10 000 cycles). One-way ANOVA, two-way, andKruskal-Wallistests were employed to treat the data (ɑ= 0.05). Varying the functional monomers had a large impact on DC,max, as confirmed by one-way ANOVA (p<0.001). The highest was obtained for HEMA (64 ± 3%). The HEMA and HEAA formulations were found to be significantly more toxic at concentrations below 100%. For microleakage, having a functional monomer or not did not show any improvement, irrespective of margin or aging period (Mann-Whitney U,p> 0.05). Larger functional monomers MDP and GPDM affected polymerization properties. Conversely, their acidity did not seem to be detrimental to cell metabolic activity. Regarding sealing ability, it seems that the functional monomers did not bring an advantage to the composites. Varying the functional monomer in SACs had a clear impact on the polymerization kinetics as well as on their cytotoxic potential. However, it did not confer better microleakage and sealing. Claiming self-adhesiveness based only on functional monomers seems dubious.
Collapse
Affiliation(s)
- Marta Nunes Ferreira
- Egas Moniz Center for Interdisciplinary Research (CiiEM); Egas Moniz School of Health & Science, 2829-511 Caparica, Almada, Portugal
| | - Marta Neves Dos Santos
- Egas Moniz Center for Interdisciplinary Research (CiiEM); Egas Moniz School of Health & Science, 2829-511 Caparica, Almada, Portugal
| | - Inês Fernandes
- Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment, Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
| | - Carlos Miguel Marto
- Institute of Experimental Pathology, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Institute of Biophysics, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment, Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotechnology (CIBB), University of Coimbra, 3000-548 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
| | - Mafalda Laranjo
- Institute of Biophysics, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment, Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotechnology (CIBB), University of Coimbra, 3000-548 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
| | - Diana Silva
- Egas Moniz Center for Interdisciplinary Research (CiiEM); Egas Moniz School of Health & Science, 2829-511 Caparica, Almada, Portugal
- Centro de Química Estrutural, Institute of Molecular Sciences and Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal
| | - Ana Paula Serro
- Egas Moniz Center for Interdisciplinary Research (CiiEM); Egas Moniz School of Health & Science, 2829-511 Caparica, Almada, Portugal
- Centro de Química Estrutural, Institute of Molecular Sciences and Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal
| | - Eunice Carrilho
- Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment, Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotechnology (CIBB), University of Coimbra, 3000-548 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
- Faculty of Medicine, Institute of Integrated Clinical Practice, University of Coimbra, 3004-531 Coimbra, Portugal
| | - Maria Filomena Botelho
- Institute of Biophysics, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment, Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotechnology (CIBB), University of Coimbra, 3000-548 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
| | - Ana Mano Azul
- Egas Moniz Center for Interdisciplinary Research (CiiEM); Egas Moniz School of Health & Science, 2829-511 Caparica, Almada, Portugal
| | - António Hs Delgado
- Egas Moniz Center for Interdisciplinary Research (CiiEM); Egas Moniz School of Health & Science, 2829-511 Caparica, Almada, Portugal
- Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, NW3 2PF London, United Kingdom
| |
Collapse
|
16
|
Liu Y, Sakaguchi N, Iijima M, Islam MRR, Zhang J, Islam R, Yamauti M, Sano H, Tomokiyo A. Effects of Short-Term Exposure of Chloramine-T Solution on the Characteristics of Light-Cured and Chemical-Cured Adhesives. Polymers (Basel) 2023; 15:3995. [PMID: 37836044 PMCID: PMC10575163 DOI: 10.3390/polym15193995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/27/2023] [Accepted: 10/02/2023] [Indexed: 10/15/2023] Open
Abstract
This study evaluated the effect of a 0.5% chloramine T solution on a chemical-cured universal adhesive by comparing the light-cured, one-step, self-etch adhesive for the bonding performance, mechanical properties, and resin-dentin interfacial characteristics. Caries-free human molars were randomly assigned into eight groups based on the bonding systems employed (Bond Force II, BF and Bondmer Lightless, BL), the immersion solutions used before bonding (0.5% chloramine T solution and distilled water), and the immersion durations (5 and 60 min). Microtensile bond strength (μTBS), nanoleakage evaluation, and nanoindentation tests were performed, and the surface morphology of the resin-dentin interface was examined using a focus ion beam/scanning ion microscopy system. Immersion in chloramine-T for 5 min significantly decreased the μTBS of Bondmer Lightless (from 22.62 to 12.87 MPa) compared with that in distilled water. Moreover, there was also a decreasing trend after immersing in chloramine-T for 60 min (from 19.11 to 13.93 MPa). Chloramine T was found to have no effect on the hardness, elastic modulus, or morphological characteristics of the ion-beam milled resin-dentin interfacial surfaces in the tested adhesives, suggesting that chloramine T might reduce the bond strength by interfering with the interaction and the sealing between the adhesive resin and dentin in the chemical-cured universal adhesive, albeit without affecting the mechanical properties.
Collapse
Affiliation(s)
- Yunqing Liu
- Department of Restorative Dentistry, Faculty of Dental Medicine, Hokkaido University, Sapporo 0608586, Japan; (R.I.); (M.Y.); (H.S.); (A.T.)
| | - Norihito Sakaguchi
- Center for Advanced Research of Energy Technology, Faculty of Engineering, Hokkaido University, Sapporo 0608628, Japan;
| | - Masahiro Iijima
- Department of Oral Growth and Development, Division of Orthodontics and Dentofacial Orthopedics, Health Sciences University of Hokkaido, Ishikari-Tobetsu 0610293, Japan;
| | - Md Refat Readul Islam
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Sapporo 0608586, Japan; (M.R.R.I.); (J.Z.)
| | - Jiayuan Zhang
- Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Sapporo 0608586, Japan; (M.R.R.I.); (J.Z.)
| | - Rafiqul Islam
- Department of Restorative Dentistry, Faculty of Dental Medicine, Hokkaido University, Sapporo 0608586, Japan; (R.I.); (M.Y.); (H.S.); (A.T.)
| | - Monica Yamauti
- Department of Restorative Dentistry, Faculty of Dental Medicine, Hokkaido University, Sapporo 0608586, Japan; (R.I.); (M.Y.); (H.S.); (A.T.)
| | - Hidehiko Sano
- Department of Restorative Dentistry, Faculty of Dental Medicine, Hokkaido University, Sapporo 0608586, Japan; (R.I.); (M.Y.); (H.S.); (A.T.)
| | - Atsushi Tomokiyo
- Department of Restorative Dentistry, Faculty of Dental Medicine, Hokkaido University, Sapporo 0608586, Japan; (R.I.); (M.Y.); (H.S.); (A.T.)
| |
Collapse
|
17
|
Comisi JC, Maucoski C, Beller JP, Dennis KS, Price RB. A Blinded Comparative Study of Four Commercially Available LEDs and a Laser Light Curing Device. Eur J Dent 2023; 17:1065-1074. [PMID: 36574780 PMCID: PMC10756821 DOI: 10.1055/s-0042-1757908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
OBJECTIVE This study determined the effectiveness of five light-curing units (LCUs; four light-emitting diode [LED] and one laser) used on different settings to photo-activate four conventional resin-based composites (RBCs). MATERIALS AND METHODS A total of 108 RBC specimens were photo-activated in a white Delrin mold representing a mesial-occlusal-distal (MOD) class II restoration in a molar tooth. The proximal boxes were 5 mm deep, and the mesial-distal length was 12 mm. Immediately after photo-curing, the RBC specimens were immersed in a solvent to remove the uncured materials, after which they were photographed and deidentified. A Research Electronic Data Capture survey was created using these images and sent to respondents who blindly assessed the ability of the various LCUs to photo-cure the MOD restorations. RESULTS There were significant differences in how the five curing lights had cured RBCs. One-way analysis of variance (ANOVA), pairwise t-test, Welch's one-way ANOVA, and Kruskal-Wallis rank test in the blinded survey data showed significant differences between the LED curing lights used for two 10-second cures and the laser curing light used for 1 second, and LED lights at lower settings. CONCLUSION There was a significant difference in how the curing lights could photo-cure the RBCs used in this study. The laser curing light used for 1 second produced the worst results in all four RBCs.
Collapse
Affiliation(s)
- John C. Comisi
- Department of Oral Rehabilitation, James B. Edwards College of Dental Medicine, Medical University of South Carolina, Charleston, South Carolina, United States
| | - Cristiane Maucoski
- Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Jonathan P. Beller
- Department of Oral Rehabilitation, James B. Edwards College of Dental Medicine, Medical University of South Carolina, Charleston, South Carolina, United States
| | - Kyle S. Dennis
- Department of Oral Rehabilitation, James B. Edwards College of Dental Medicine, Medical University of South Carolina, Charleston, South Carolina, United States
| | - Richard B. Price
- Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Nova Scotia, Canada
| |
Collapse
|
18
|
Maravić T, Mazzitelli C, Mancuso E, Del Bianco F, Josić U, Cadenaro M, Breschi L, Mazzoni A. Resin composite cements: Current status and a novel classification proposal. J ESTHET RESTOR DENT 2023; 35:1085-1097. [PMID: 36924395 DOI: 10.1111/jerd.13036] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/02/2023] [Accepted: 03/03/2023] [Indexed: 03/18/2023]
Abstract
OBJECTIVES Currently, a classification of resin cements that includes relatively recently formulated ("universal") cements is lacking. Furthermore, the terminology used to define different resin cements in the scientific reports is inconsistent. Accordingly, this work aims to: (i) propose a novel classification of resin composite cements; (ii) disambiguate the term "universal cements" and (iii) present an overview of the properties of these cements. METHODS An analysis of peer-reviewed literature (PubMed search), as well as market research on definitive resin composite cements were performed. RESULTS A tendency toward simplified and versatile luting materials was observed both in the scientific literature and on the dental market with the advent of self-adhesive/one-step resin cements. However, additional priming procedures were necessary to improve their bonding performance in certain clinical situations. Hence, several cements that can be applied both in adhesive and self-adhesive mode were introduced. These cements are associated with a universal adhesive resin, that can be used as a tooth and/or restorative material primer, without the need for other priming systems, regardless of the substrate. These systems should be considered truly universal. Therefore, we hereby suggested a new classification of resin-based cements: (1) adhesive/multi-step; (2) self-adhesive/one-step; (3) universal cements (one- or multi-step). Despite promising in vitro results, clinical trials and long-track laboratory studies are necessary to confirm the reliability of the universal cements. CONCLUSIONS This review presented the current advances in the field of resin-based cements, which are reflected in the proposed classification. The term "universal cement" was disambiguated, which will help standardize the terminology used in published research. CLINICAL SIGNIFICANCE The classification of resin-based cements and a better understanding of the proper terminology will help standardize the terminology in published research, as well as improve the understanding of the clinical practitioners of the different indications and possible modalities of use of the available cements.
Collapse
Affiliation(s)
- Tatjana Maravić
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Claudia Mazzitelli
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Edoardo Mancuso
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Federico Del Bianco
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Uroš Josić
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Milena Cadenaro
- Department of Medical Sciences, University of Trieste, Trieste, Italy
- Department of Surgery, Institute for Maternal and Child Health - IRCCS "Burlo Garofolo", Trieste, Italy
| | - Lorenzo Breschi
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Annalisa Mazzoni
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| |
Collapse
|
19
|
Assis HCD, Bertolini GR, Sousa-Neto MD, Lopes-Olhê FC. Analysis of the adhesive interface of dentine treated with carbodiimide and chitosan before cementation of fiberglass posts with different resin cements. J Biomed Mater Res B Appl Biomater 2023; 111:1840-1852. [PMID: 37287402 DOI: 10.1002/jbm.b.35289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 03/27/2023] [Accepted: 05/18/2023] [Indexed: 06/09/2023]
Abstract
The objective of this study is to evaluate the effect of 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) and chitosan (CHI) on the adhesive interface of resin cements to root dentine. Forty-five upper canines were sectioned, endodontically treated, prepared and divided into three groups according to dentine treatment (distilled water-DW, CHI 0.2% and EDC 0.5) and in three subgroups according to resin cement: RelyX ARC, Panavia F 2.0 or RelyX U200. Slices were obtained, with five slices of each third submitted to the analysis of the adaptation of the adhesive interface through scores and the perimeter with gaps in confocal laser scanning microscopy and one slice of each third later evaluated qualitatively in scanning electron microscopy. The results were analyzed using with Kruskal-Wallis and Spearman correlation tests. There was no difference in adaptation for the different resin cements (p = .438). EDC presented better adaptation when compared to the groups treated with DW and CHI (p < .001), while the CHI and DW presented similar adaptation values (p = .365). No difference was observed in the perimeter referring to the gap areas for the different resin cements (p = .510). EDC showed a lower percentage of perimeters with gaps when compared to CHI (p < .001), with the percentage of perimeter with gaps of teeth treated with CHI being lower than DW (p < .001). A positive correlation coefficient equal to 0.763 was obtained between the perimeter with gaps and the adaptation data of the adhesive interface (p < .001). EDC resulted in better adaptation of the adhesive interface and a lower percentage of perimeters with gaps compared to chitosan.
Collapse
Affiliation(s)
- Helena Cristina de Assis
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, Brazil
| | - Gunther Ricardo Bertolini
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, Brazil
| | - Manoel Damião Sousa-Neto
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, Brazil
| | - Fabiane Carneiro Lopes-Olhê
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, Brazil
| |
Collapse
|
20
|
Breschi L, Josic U, Maravic T, Mancuso E, Del Bianco F, Baldissara P, Mazzoni A, Mazzitelli C. Selective adhesive luting: A novel technique for improving adhesion achieved by universal resin cements. J ESTHET RESTOR DENT 2023; 35:1030-1038. [PMID: 36971211 DOI: 10.1111/jerd.13037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/22/2022] [Accepted: 03/08/2023] [Indexed: 03/29/2023]
Abstract
OBJECTIVE We aimed to introduce the concept of "Selective adhesive luting-SAL" which is explained through clinical steps and supported by preliminary laboratory evidence. CLINICAL CONSIDERATIONS Cementation with rubber dam is difficult to perform in case of short abutment teeth and/or subgingival crown margins. By means of universal resin cements/universal adhesive systems, which can be employed in self-adhesive as well as adhesive luting procedures, this paper presents a novel technique allowing clinicians to perform reliable cementation where rubber dam isolation is difficult. The SAL technique entails the application of a universal adhesive system only on easily accessible abutment surfaces, enabling simultaneous adhesive and self-adhesive luting in different portions of the abutment. The SAL clinical workflow is explained through prosthodontic rehabilitation of maxillary right central incisor affected by microdontia and restored with a lithium-disilicate crown. Furthermore, our laboratory microshear bond strength study supports the rationale behind SAL application demonstrating higher bond strength even when the adhesive resin is placed only on one portion of the cementation substrate. CLINICAL SIGNIFICANCE This article advocates the application of SAL technique in clinical situations where effective adhesive luting is uncertain, since it can improve the adhesion between the tooth and universal resin cements.
Collapse
Affiliation(s)
- Lorenzo Breschi
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Uros Josic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Tatjana Maravic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Edoardo Mancuso
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Federico Del Bianco
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Paolo Baldissara
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Annalisa Mazzoni
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Claudia Mazzitelli
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| |
Collapse
|
21
|
Dietschi D, Askari M, Rossier I, Caseiro L, Krejci I, Leprince JG, Di Bella E, Ardu S. Marginal Adaptation of In Vitro Class II Restorations Made Out of Bulk or Conventional Composite Using Single- or Multi-Layered Techniques. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6325. [PMID: 37763602 PMCID: PMC10533156 DOI: 10.3390/ma16186325] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 09/14/2023] [Accepted: 09/19/2023] [Indexed: 09/29/2023]
Abstract
Objective: Testing the influence of various restorative materials (conventional or bulkfill composites) and filling techniques (single- or multi-layered techniques) on the in vitro marginal adaptation of large class II direct composites with supra and sub-gingival margins subjected to thermomechanical loading (TML). Methods: A total of 40 prepared teeth were attributed randomly to five experimental groups. In Group 1, restorations were made of multi-layered high-viscosity conventional composite (Tetric EvoCeram); in Groups 2 and 3, restorations were made of a high viscosity bulkfill composite (Tetric EvoCeram Bulk Fill) applied in one (Group 2) or three layers (Group 3); in Groups 4 and 5, restorations were made of a flowable bulkfill composite (SDR flow) applied in one (Group 4) or two layers (Group 5), covered with a layer of high-viscosity conventional composite (Ceram-X Universal). A single adhesive (OptiBond FL) was used in all groups. All specimens were submitted to a staged TML comprising three phases (2 × 500,000 and 1,000,000 cycles) at 50 N with 3350 thermal cycles (5 to 55 °C) every 500,000 cycles. The tooth-restoration interfaces on proximal surfaces were evaluated quantitatively by scanning electron microscopy, before and after each TML phase, hence at three timepoints (T0, T1, T2 and T3). The following segments were considered for evaluation: proximal, vertical enamel margins (assessed individually on both restoration sides), cervical enamel (restoration side above CEJ) and cervical dentin margin (restoration side below the CEJ). Results: TML induced a significant reduction in continuous adaptation at both enamel and dentin margins in all groups, with percentages of continuous margins ranging from 75.2 to 91.8% at T0, and decreasing to values ranging from 21.3 to 73.9% at T3. Both composite systems and layering protocols had a significant influence on marginal adaptation of the restorations, with statistical associations depending on the restoration group and the timepoint considered. Defective margins in enamel were all of a cohesive nature with micro-fractures, while in dentin, interfacial gaps were the main defect observed. Conclusions/Clinical significance: The present results highlighted significant degradation of marginal adaption after long-term in vitro fatigue test using materials even with high-viscosity conventional resin composites, applied with a proper layering approach in medium-large sub-gingival cavities. While no significant differences were observed at the dentin cervical margins, there was a tendency for better adaptation at the enamel margin when using a higher modulus material with a multi-layered technique.
Collapse
Affiliation(s)
- Didier Dietschi
- Division of Cariology and Endodontology, Section of Dental Medicine, Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland; (D.D.); (M.A.); (I.R.); (L.C.); (I.K.); (J.G.L.)
| | - Mustafa Askari
- Division of Cariology and Endodontology, Section of Dental Medicine, Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland; (D.D.); (M.A.); (I.R.); (L.C.); (I.K.); (J.G.L.)
| | - Isaline Rossier
- Division of Cariology and Endodontology, Section of Dental Medicine, Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland; (D.D.); (M.A.); (I.R.); (L.C.); (I.K.); (J.G.L.)
| | - Luciana Caseiro
- Division of Cariology and Endodontology, Section of Dental Medicine, Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland; (D.D.); (M.A.); (I.R.); (L.C.); (I.K.); (J.G.L.)
| | - Ivo Krejci
- Division of Cariology and Endodontology, Section of Dental Medicine, Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland; (D.D.); (M.A.); (I.R.); (L.C.); (I.K.); (J.G.L.)
| | - Julian Gregoire Leprince
- Division of Cariology and Endodontology, Section of Dental Medicine, Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland; (D.D.); (M.A.); (I.R.); (L.C.); (I.K.); (J.G.L.)
| | - Enrico Di Bella
- Department of Political and International Studies, University of Genoa, 16126 Genoa, Italy;
| | - Stefano Ardu
- Division of Cariology and Endodontology, Section of Dental Medicine, Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland; (D.D.); (M.A.); (I.R.); (L.C.); (I.K.); (J.G.L.)
| |
Collapse
|
22
|
Cavalcanti KGBA, Pulido C, Moreira PHA, Monteles CF, Salvatierra BLC, Siqueira FSF, Soares CJ, Reis A, Loguercio AD, Cardenas AFM. Effect of irradiance and exposure time on the adhesive properties of universal adhesives after 2 years of storage. Clin Oral Investig 2023; 27:5223-5232. [PMID: 37458867 DOI: 10.1007/s00784-023-05142-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 07/04/2023] [Indexed: 09/10/2023]
Abstract
OBJECTIVE This study aims to evaluate the effects of exposure time and irradiance on the dentin bonding properties (microtensile bond strength (μTBS) and nanoleakage (NL)) of the Clearfil Universal Bond Quick (CUQ) adhesive and Scotchbond Universal Adhesive (SBU) immediately and after 2 years of water storage. MATERIAL AND METHODS Hence, 128 human molars were randomly assigned to 16 groups based on adhesive strategy, irradiance/exposure times, and storage time for each universal adhesive tested. The adhesives were applied using the etch-and-rinse and self-etch strategies and were light-cured using four different irradiance/exposure times: 1400 mW/cm2 for 5 s (1400 × 5), 1400 mW/cm2 for 10 s (1400 × 10), 3200 mW/cm2 for 5 s (3200 × 5), and 3200 mW/cm2 for 10 s (3200 × 10). Then, each sample was restored and sectioned into a resin-dentin bonded stick to be tested for μTBS and NL (immediately and after 2 years of water storage). The mean μTBS and NL of all resin-dentin bonded sticks from the same hemi-tooth (factor time) were statistically analyzed using a three-way ANOVA and Tukey's test (a = 0.05). RESULTS Despite a significant decrease in the μTBS values for all groups after 2 years of water storage, the 3200 × 5 group showed higher μTBS values, whereas the 3200 × 10 group showed lower μTBS values for both universal adhesives tested. Although a significant increase in the NL values was observed for all groups after 2 years of water storage, the 3200 × 10 group showed higher NL values than the other groups (p < 0.001). CONCLUSION Results indicate that light-curing the adhesive layer with 14-16 J/cm2 led to an improvement in the stability of the resin-dentin adhesive interface. A longer exposure time (10 s) coupled with a higher irradiance (3200 mW/cm2) resulted in a greater degree of degradation of the adhesive interface. CLINICAL SIGNIFICANCE To guarantee better stability of the adhesive interface, clinicians could be preferred a light-cured universal adhesive layer with 14-16 J/cm2. Higher irradiances should be avoided.
Collapse
Affiliation(s)
| | - Camilo Pulido
- Department of Restorative Dentistry and Biomaterials, San Francisco de Quito University, Quito, Ecuador
| | - Pedro H A Moreira
- Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Camila F Monteles
- Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Byron L C Salvatierra
- Department of Restorative Dentistry, Ponta Grossa State University, Rua Carlos Cavalcanti, 4748, Bloco M, Sala 64A-Uvaranas, Ponta Grossa, Paraná, 84030-900, Brazil
| | | | - Carlos J Soares
- Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
- Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - Alessandra Reis
- Department of Restorative Dentistry, Ponta Grossa State University, Rua Carlos Cavalcanti, 4748, Bloco M, Sala 64A-Uvaranas, Ponta Grossa, Paraná, 84030-900, Brazil
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, Ponta Grossa State University, Rua Carlos Cavalcanti, 4748, Bloco M, Sala 64A-Uvaranas, Ponta Grossa, Paraná, 84030-900, Brazil.
| | | |
Collapse
|
23
|
Maucoski C, Price RB, Arrais CAG. Irradiance from 12 LED light curing units measured using 5 brands of dental radiometers. J ESTHET RESTOR DENT 2023; 35:968-979. [PMID: 37560968 DOI: 10.1111/jerd.13107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/29/2023] [Accepted: 07/05/2023] [Indexed: 08/11/2023]
Abstract
OBJECTIVE To evaluate the accuracy of five brands of radiometers in reporting the irradiance (mW/cm2 ) from twelve brands of LCUs compared to a 'Gold Standard' (GS) reference obtained from a hand-held laboratory-grade radiometer. MATERIALS AND METHODS The irradiance was measured from two examples of twelve brands of previously used LCUs on two examples of five brands of dental radiometers. The emission spectrum was also obtained. Irradiance data from each brand of LCU against each meter was analyzed using the Shapiro-Wilk test for normality. The irradiance values were subjected to a two-way ANOVA followed by Bonferroni tests for each LCU brand. Finally, a descriptive analysis was made using a 95% confidence interval around the mean irradiance. RESULTS The power output from the LCUs ranged from 271 mW to 1005 mW. Among the tested radiometers, only the Bluephase Meter II could accurately report the irradiance from 11 out of the 12 brands of LCU evaluated in this study. When measured using the "GS" system, the mean irradiance values from the two examples of nine brands of previously used LCU were not always within ±10% of the irradiance values stated by the manufacturer. CONCLUSIONS The mean irradiance values from 9 of the 12 brands of used LCUs were beyond ±10% of the irradiance values stated by the manufacturer. Only the Bluephase Meter II could accurately report the irradiance from 11 out of the 12 brands of LCU evaluated in this study. CLINICAL SIGNIFICANCE There was a wide range in the power output from the LCUs tested. It was impossible to accurately measure the irradiance from all the LCUs using the dental radiometers examined. However, dental radiometers should still be used in dental offices to monitor the light output from LCUs and verify that they are working correctly before they are used on patients.
Collapse
Affiliation(s)
- Cristiane Maucoski
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | | |
Collapse
|
24
|
Bedir MGA, Karadas M, Bedir F. Effect of matrix metalloproteinase inhibitors on bonding durability of universal adhesives. Dent Mater J 2023; 42:581-590. [PMID: 37302822 DOI: 10.4012/dmj.2022-282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
This study aimed to evaluate the effect of different matrix metalloproteinase inhibitors (MMPIs) on the microtensile bond strength (μTBS) and nanoleakage of universal adhesives. One hundred twenty non-carious human molars were prepared and randomly assigned to two groups: Scotchbond Bond Universal (SBU) and Gluma Bond Universal (GBU). The samples in each group were assigned to five subgroups (n=12) based on one control (water) and four MMPIs (Benzalkonium-chloride (BAC), Batimastat (BB94), Chlorhexidine (CHX), and Epigallocatechin-gallate (EGCG)). Each adhesive was applied in self-etch (SE) mode or etch-and-rinse (ER) mode. Dentin/composite sticks were fabricated and subjected to the μTBS test after 24 h or 6 months. At 6 months, MMPIs did not affect the μTBS of the adhesives, regardless of etching mode. Nanoleakage was more pronounced in ER mode than in SE mode for all subgroups. All MMPIs, with the exception of CHX, decreased the nanoleakage of GBU in ER mode.
Collapse
Affiliation(s)
| | - Muhammet Karadas
- Department of Restorative Dentistry, Faculty of Dentistry, Recep Tayyip Erdogan University
| | - Fatih Bedir
- Department of Restorative Dentistry, Faculty of Dentistry, Recep Tayyip Erdogan University
| |
Collapse
|
25
|
Moreira MA, Silveira VR, Alcantara VO, Sousa FB, Sousa BC. Prior Restorative Procedures to Endodontic Treatment. Cureus 2023; 15:e37106. [PMID: 37153307 PMCID: PMC10158847 DOI: 10.7759/cureus.37106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/04/2023] [Indexed: 04/07/2023] Open
Abstract
Tooth loss due to fracture and the failure of endodontic treatment (ET) are common situations in teeth with extensive tissue destruction. This is due to the fragility of the remaining dental structure and the difficulty in sealing cavities, which is sometimes associated with the violation of the supracrestal insertion tissue. The previous restoration of marginal ridges or cusps with composite resin (CR) restores their fracture resistance, due to the adhesive characteristics of the restorative material, while also protecting the quality of endodontic treatment through better sealing. However, the protocol adopted in teeth requiring endodontic treatment involves performing the restorative procedure only after the endodontic procedures. The objective of this study was to report a case in which restoration of marginal ridges and/or cusps was performed prior to endodontic treatment, focusing on maintaining the tooth in function without dental fracture. The restoration was performed with an inverted operative sequence before the endodontic treatment. There was a violation of the supracrestal insertion tissue, requiring crown lengthening surgery (CLS) prior to the restorative procedure. Clinical and radiographic evaluations were performed postoperatively at seven days, three, six, and nine months, and five years. Tooth function was maintained without dental fractures or restoration loss. Periradicular space healing occurred with the disappearance of the lesion. Performing the restorative procedure prior to endodontic treatment in teeth with extensive coronal destruction is an alternative technique that facilitates clinical procedures, reduces the likelihood of dental loss due to fracture, and promotes endodontic treatment success.
Collapse
|
26
|
Lu Y, Xu X, Li J. Recent advances in adhesive materials used in the biomedical field: adhesive properties, mechanism, and applications. J Mater Chem B 2023; 11:3338-3355. [PMID: 36987937 DOI: 10.1039/d3tb00251a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023]
Abstract
Adhesive materials are natural or synthetic polymers with the ability to adhere to the surface of luminal mucus or epithelial cells. They are widely used in the biomedical field due to their unique adhesion, biocompatibility, and excellent surface properties. When used in the human body, they can adhere to an accessible target and remain at the focal site for a longer period, improving the therapeutic effect on local disease. An adhesive material with bacteriostatic properties can play an antibacterial role at the focal site and the adhesive properties of the material can prevent the focal site from being infected by bacteria for a period. In addition, some adhesive materials can promote cell growth and tissue repair. In this review, the properties and mechanism of natural adhesive materials, organic adhesive materials, composite adhesive materials, and underwater adhesive materials have been introduced systematically. The applications of these adhesive materials in drug delivery, antibacterials, tissue repair, and other applications are described in detail. Finally, we have discussed the prospects and challenges of using adhesive materials in the field of biomedicine.
Collapse
Affiliation(s)
- Yongping Lu
- College of Polymer Science and Engineering, State Key Laboratory of Polymer, Sichuan University, Chengdu 610041, P. R. China.
| | - Xinyuan Xu
- College of Polymer Science and Engineering, State Key Laboratory of Polymer, Sichuan University, Chengdu 610041, P. R. China.
| | - Jianshu Li
- College of Polymer Science and Engineering, State Key Laboratory of Polymer, Sichuan University, Chengdu 610041, P. R. China.
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, P. R. China
- Med-X Center for Materials, Sichuan University, Chengdu 610041, P. R. China
| |
Collapse
|
27
|
Zabeu GS, Giacomini MC, Scaffa PMC, Tjäderhane L, Mosquim V, Wang L. Solvation role of dimethyl sulfoxide on the interaction with dentin bonding systems after 30 months. Dent Mater 2023; 39:478-484. [PMID: 36934035 DOI: 10.1016/j.dental.2023.03.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 02/07/2023] [Accepted: 03/03/2023] [Indexed: 03/18/2023]
Abstract
OBJECTIVES To determine whether DMSO could serve as an effective pretreatment to improve the mechanical properties and minimize the degradation of the adhesive interface, through the degree of conversion (DC) and bond strength to dentin of different categories of dentin bonding systems (DBSs) after 30 months. METHODS DMSO (0, 0.5, 1, 2, 5, 10 vol%) were incorporated into four categories of DBSs: Adper Scotchbond Multipurpose (MP), Adper Single Bond 2 (SB), Clearfil SE Bond (CSE) and Adper Scotchbond Universal (SU). DC was evaluated by Fourier transform infrared spectroscopy (FTIR). For microtensile bond strength test (µTBS), 1 % DMSO were applied on dentin as pretreatment before DBSs. For SU, both strategies were tested. Specimens for µTBS were tested after 24 h, 6 and 30 months. DC and µTBS data were subjected to two-way ANOVA and Tukey test (α < 0.05). RESULTS Incorporating 5 %/10 % DMSO increased the DC of CSE. Controversially, when combined with SU, 2 % and 10 % DMSO jeopardized the DC. Regarding µTBS, 1 % DMSO pre-treatment increased the bond strength for MP, SB, SU-ER and SU-SE. After 30 months, MP, SU-ER and SU-SE showed a decrease compared to baseline but remained higher than the control. CLINICAL SIGNIFICANCE DMSO pretreatment may be a useful strategy to improve the bond interface over time. Its incorporation seems to favor the non-solvated systems regarding DC while it seems to show long-term benefits for bond strength using 1 % DMSO for MP and SU systems.
Collapse
Affiliation(s)
- Giovanna Speranza Zabeu
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla, 9-75, zip code 17012-901 Bauru, SP, Brazil; School of Dentistry, Centro Universitário Sagrado Coração - UNISAGRADO, Rua Irmã Arminda, 10-50, Jardim Brasil, zip code 17011-160 Bauru, SP, Brazil
| | - Marina Ciccone Giacomini
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla, 9-75, zip code 17012-901 Bauru, SP, Brazil; University Centre Integrated Faculties of Ourinhos, Rodovia BR-153, Km 338 S/N Água do Cateto, zip code 19909-100 Ourinhos, SP, Brazil
| | - Polliana Mendes Candia Scaffa
- Division of Biomaterials and Biomechanics, Department of Restorative Dentistry, Oregon Health & Science University, OHSU, 2730 SW Moody Ave, zip code 97201 Portland, OR, USA
| | - Leo Tjäderhane
- Department of Oral and Maxillofacial Diseases, University of Helsinki, Helsinki, Finland; Helsinki University Hospital, Helsinki, zip code 90220, Oulu, Finland; Research Unit of Oral Health Sciences and Medical Research Center Oulu (MRC Oulu), Oulu University Hospital, Kajaanintie 50, zip code 90220 Oulu, Finland
| | - Victor Mosquim
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla, 9-75, zip code 17012-901 Bauru, SP, Brazil
| | - Linda Wang
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla, 9-75, zip code 17012-901 Bauru, SP, Brazil.
| |
Collapse
|
28
|
Are universal adhesives in etch-and-rinse mode better than old 2-step etch-and-rinse adhesives? One-year evaluation of bonding properties to dentin. J Dent 2023; 132:104481. [PMID: 36918052 DOI: 10.1016/j.jdent.2023.104481] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 02/22/2023] [Accepted: 03/08/2023] [Indexed: 03/14/2023] Open
Abstract
OBJECTIVES This study compared the bonding properties of dentin of three 2-step etch-and-rinse adhesives (2-ERAs) to those of three universal adhesives (UAs) applied with an etch-and-rinse strategy (ER), immediately and after 1 year of water storage. METHODS Sixty caries-free molars were divided into 6 groups according to the adhesive systems used (n = 10). The 2-ERA systems included were: 1) Adper Single Bond 2 (SB), 2) Tetric N-Bond (TB), and 3) Ambar (AM); and the UAs systems were: 4) Single Bond Universal (SBU) 5) Tetric N-Bond Universal (TBU), and 6) Ambar Universal (AMU). The occlusal third of each tooth was removed and the adhesives were applied. After the composite build-up, specimens were sectioned and tested for microtensile bond strength (µTBS) and nanoleakage (NL) immediately and after 1 year of water storage. In situ degree of conversion (DC) was only evaluated in the immediate time. For water sorption (WS), solubility (SO), and mass change (MC) tests, 48 disk-shaped specimens were prepared (n = 8) and assessed according to ISO 4049:2009. RESULTS UAs showed higher µTBS and lower NL values than 2-ERAs did after 1 year of water storage (p = 0.001). Regarding DC, 2-ERAs showed higher DC values than UAs (p = 0.001). Regarding WS, 2-ERAs showed higher WS values than those of UAs (p = 0.00001), except for AM and AMU. Lower WS was observed for AM than for other 2-ERAs (p = 0.00001). CONCLUSION The use of UAs applied with the ER strategy seems to be a more effective technique for maintaining adhesion to dentin substrate than 2-ERAS. CLINICAL SIGNIFICANCE This study may support clinicians in selecting the most adequate adhesive system to be used in ER strategy in dentin, demonstrating that UAs were more effective, considering the longevity of the resin restorations.
Collapse
|
29
|
Free-radical polymerization in a droplet with initiation at the interface. Eur Polym J 2023. [DOI: 10.1016/j.eurpolymj.2023.112002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2023]
|
30
|
Synthesis, characterization, photo-polymerization, hydrolytic stability, and etching behavior of new self-etch adhesive monomers. J Mech Behav Biomed Mater 2023; 139:105693. [PMID: 36731189 DOI: 10.1016/j.jmbbm.2023.105693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Revised: 01/24/2023] [Accepted: 01/25/2023] [Indexed: 02/03/2023]
Abstract
Considering the poor hydrolytic stability of the most methacrylate-based functional monomers of self-etch dental adhesives in acidic and aqueous conditions, in this study allyl-based photo-polymerizable self-etch monomers was synthesized in order to improve the hydrolytic stability. The new self-etch monomers based on phosphonic acid functional groups were synthesized through a two-step procedure. First, phosphoric anhydride, poly-phosphoric acid, and polyethylene glycol were reacted to produce phosphate ester precursor (P-PEG-P). Next, allyl 2, 3-epoxypropyl ether was reacted with P-PEG-P to synthesize allyl self-etch monomer. Glycidyl methacrylate was also reacted with P-PEG-P to synthesize a methacrylate self-etch analogue monomer. The monomers were characterized using FTIR and 1H-NMR spectroscopy. The viscosities of monomers were measured using a rheometer. The degree photopolymerization conversion of monomers was measured using FTIR spectroscopy. The pH assay was performed by a digital pH-meter. The etching behavior of the monomers on human teeth was studied using scanning electron microscopy (SEM). Thermo-gravimetric analysis (TGA) was performed to evaluate the possible interaction of the monomers with tricalcium phosphate (TCP). The solubility of synthesized monomers was examined in ethanol, acetone, and water. The hydrolytic stability of cured resins in artificial saliva during 4 months was also surveyed. The synthesis of new self-etching monomers was successfully confirmed by spectroscopy analyses. The results represented appropriate viscosity of self-etching monomers around 1 (Pa s). The resin containing methacrylate monomer exhibited its degree of conversion is more than that of allyl monomer (p < 0.05). The allyl and methacrylate self-etch monomers exhibited pH values of 1.2 and 1.3, respectively. SEM micrograph verified that the synthesized monomers were able to suitable etching of the enamel human premolar teeth. The data obtained from TGA tests revealed that thermal stability of (TCP) containing monomers is enhanced. Also, the monomers exhibited an excellent solubility in polar solvents, but when they are mixed with TCP, they are not, anymore, dissolved in these solvents. Furthermore, the allyl monomer showed higher hydrolytic stability than the methacrylate monomer. The new photo-polymerizable acidic monomer based on allyl functionality showed enhanced hydrolytic stability compared to methacrylate-based monomer. It may be considered as a promising monomer for self-etch dental adhesives.
Collapse
|
31
|
Enrique Cuevas-Suárez C, Aldrighi Münchow E, Gonçalves Schwarzbold C, Kuhn Rutz J, Fernandes da Silva A, Piva E. Effect of naturally derived antioxidants as polymerization inhibitors on experimental adhesive resins. J Photochem Photobiol A Chem 2023. [DOI: 10.1016/j.jphotochem.2022.114368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
32
|
Soares J, Perdigão J, Chrispim B, Lopes GC. Effect of Extra Hydrophobic Resin Layer on Bonding of Universal Adhesive Systems to Enamel. Oper Dent 2023; 48:E48-E59. [PMID: 36928743 DOI: 10.2341/21-140-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/10/2022] [Indexed: 03/18/2023]
Abstract
OBJECTIVE The objective of this study was to compare the effect of solvent in universal adhesives (UA) and the application of an extra layer of hydrophobic bonding resin on enamel shear bond strengths (SBS). METHODS AND MATERIALS Crowns of 224 bovine mandibular incisors were embedded in acrylic resin, wet-polished up to 600-grit silicon carbide paper and assigned to 3 UAs with different solvents (n=32): ethanol-based UA (ADU, AdheSE Universal, Ivoclar Vivadent); isopropanol-based UA (PBU, Prime&Bond Universal, Dentsply Sirona); and acetone-based UA (OPT, OptiBond Universal, Kerr Co). The same UAs were also applied with an extra layer of a hydrophobic bonding resin (HLB, Heliobond, Ivoclar Vivadent): ADU + HLB; PBU + HLB; and OPT + HLB. HLB alone was used as control. Enamel was etched with 37.5% H3PO4 (Kerr Gel Etchant, Kerr Co) for 15 seconds, rinsed with water, and air dried. UAs were applied according to the respective manufacturer's instructions. After adhesive application, composite cylinders (Filtek Z250, 3M Oral Care) were built up and light-cured (40 seconds/increment, 40 J/cm2) keeping the light tip in contact with the mold. Specimens were stored in water for 24 hours (24H) or for 6 months (6M). A knife-edged metallic rod (Ø=2.8-mm semicircular notch) loaded the composite cylinders until fracture. Mode of failure was analyzed with optical microscopy (40×). Statistics included twoway analysis of variance (ANOVA; adhesive strategy and water storage) and Tukey honestly significant difference (HSD) post hoc test (α=95%). RESULTS Mean enamel SBS ranged from 3.6 (±2.2) MPa (HLB/6M) to 24.7 (±7.1) MPa (ADU + HLB/6M). ANOVA revealed significant differences for adhesive strategy (p≤0.001) but no significant differences for water storage (p>0.05). All UAs resulted in similar mean enamel SBS with or without an extra layer of HLB at 24H. After 6M, only ADU resulted in higher enamel SBS when an extra layer of HLB was applied. All UAs resulted in higher mean enamel SBS than HLB (control). Most failures were adhesive exception for PBU/HLB/6M, which had mostly mixed failures. CONCLUSIONS UAs resulted in statistically higher enamel SBS than the nonsolvated hydrophobic bonding resin (control), regardless of the solvent in their composition. Application of an extra layer of hydrophobic bonding resin over UAs did not improve mean enamel SBS for isopropanol- and acetone-based UAs but did improve mean enamel SBS for the ethanol-based UA after 6M. Resin composite bonding to enamel using a hydrophobic bonding resin alone is not recommended.
Collapse
Affiliation(s)
- Jpb Soares
- José Paulo Barbosa Soares, DDS, MS, Department of Operative Dentistry, School of Dentistry, Federal University of Santa Catarina, Campus Universitário Trindade, Santa Catarina, Brazil
| | - J Perdigão
- *Jorge Perdigão, DMD, MS, PhD, Department of Restorative Sciences, Division of Operative Dentistry, University of Minnesota, Minneapolis, Minnesota, USA
| | - B Chrispim
- Bruna Chrispim, DDS, MS, Department of Operative Dentistry, School of Dentistry, Federal University of Santa Catarina, Campus Universitário Trindade, Florianópolis, Santa Catarina, Brazil
| | - G C Lopes
- Guilherme Carpena Lopes, DDS, MS, PhD, Department of Operative Dentistry, School of Dentistry, Federal University of Santa Catarina, Campus Universitário Caixa, Florianópolis, Santa Catarina, Brazil
| |
Collapse
|
33
|
Yu SY, He X, Tian ZL, Li KX, Chen H, Wang HM, Shi ZS, Zhu S, Cui ZC. Effect of Collagen-Reactive Functional Monomer on Etch-and-Rinse Adhesives. J Dent Res 2023; 102:287-294. [PMID: 36474440 DOI: 10.1177/00220345221134278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
In this study, we evaluated a novel functional monomer (4-formylphenyl acrylate [FA]) that can specifically and covalently bind to the dentin collagen matrix as a potential alternative hydrophobic diluent-like monomer for improving the durability of dentin bonding. Experimental adhesives with different FA contents (0%, 10%, 20%, and 30%) were evaluated as partial substituents for the hydrophilic monomer 2-hydroxyethyl methacrylate, with the commercial adhesive One-Step (Bisco, Inc.) employed as the positive control. Their degree of conversion, viscosity, hydrophobicity, mechanical properties, and water absorption/solubility were measured as the comprehensive characterization. In situ zymographic assays were performed to determine the extent to which FA inhibits the endogenous hydrolytic activity of dentin. Finally, the bonding performances of the novel adhesives were evaluated with microtensile strength tests and scanning electron microscopy. The results showed that the incorporation of FA significantly improved the mobility of experimental adhesives attributable to the dilution property of FA. In contrast to the possible compromised rate of polymerization by hydroxyethyl methacrylate, FA exhibited typical characteristics of favorable copolymerization with polymerizable monomers in adhesives and improved the degree of conversion of experimental adhesives. The rigidity and hydrophobic properties of the phenyl framework of the FA molecule conferred superior mechanical properties and hydrolysis resistance to the novel experimental adhesives. An inhibitory effect on gelatinolytic activities within the hybrid layer was also observed in the in situ zymographic assays, even at a low FA concentration (10%). In conjunction with the significantly improved infiltration found via scanning electron microscopy, the experimental adhesives containing FA possessed significantly better-maintained microtensile strength, even after aging. Thus, the incorporation of this novel monomer endowed the experimental adhesives with multiple enhanced functionalities. These remarkable advantages highlight the suitability of the monomer for further applications in clinical practice.
Collapse
Affiliation(s)
- S Y Yu
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - X He
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - Z L Tian
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - K X Li
- State Key Laboratory of Supramolecular Structures and Materials, College of Chemistry, Jilin University, Changchun, China
| | - H Chen
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - H M Wang
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - Z S Shi
- State Key Laboratory of Supramolecular Structures and Materials, College of Chemistry, Jilin University, Changchun, China
| | - S Zhu
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - Z C Cui
- State Key Laboratory of Supramolecular Structures and Materials, College of Chemistry, Jilin University, Changchun, China
| |
Collapse
|
34
|
Eusufzai SZ, Barman A, Jamayet NB, Ahmad WMAW, Mahdi SS, Sheikh Z, Daood U. Effects of Riboflavin Collagen Crosslinker on Dentin Adhesive Bonding Efficiency: A Systematic Review and Meta-Analysis. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1701. [PMID: 36837334 PMCID: PMC9963098 DOI: 10.3390/ma16041701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 02/06/2023] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
The aim of this study was to evaluate published data regarding riboflavin (RF) as a cross-linker for improved adhesive bond strength to dentin and to analyze previous studies for optimal concentration of riboflavin range suitable for dentin bond. Saliva and distilled water were used as storage media and aging time was 24 h and 6 months. Results of meta-analysis were synthesized using a statistical method of inverse variance in random effects with a 95% Confidence Interval (CI). Cochrane review manager 5.4.1 was used to determine results of the meta-analysis. In total, 3172 articles were found from search databases "PubMed", "Scopus", and "Google Scholar". Six of the fifteen studies were eligible for meta-analysis. Micro tensile strength shows significant improvement with the addition of riboflavin (p < 0.05) compared to without the addition of riboflavin from with 95% CI. A significant difference has been found in micro tensile bond strength between use of the riboflavin cross-linker and without use of the riboflavin crosslinker in the dentin adhesive system. With a 95% confidence interval (CI), the I2 for micro tensile strength was 89% with strong heterogeneity, Chi2 = 44.76, df = 5 (p < 0.00001), and overall effect size is Z = 2.22 (p = 0.03) after immediate aging. Chiang et al. 2013 shows maximum mean differences which is 38.50 [17.93-59.07]. After 6 months of aging in distilled water or artificial saliva micro tensile bond strength has been increased with the addition of riboflavin (p < 0.05). It can be clearly seen that pooled effect and 95% CI did not cross the line of no effect. With a 95% confidence interval (CI), the I2 for micro tensile strength was 96% with strong heterogeneity, Chi2 = 117.56, df = 5 (p < 0.00001), and overall effect size is Z = 2.30 (p = 0.02). Subgroup analysis proved a similar effect of distilled water and artificial saliva as storage media on micro tensile bond strength after incorporating riboflavin as a collagen crosslinker. An artificial saliva aged forest plot also showed considerable heterogeneity with I2 = 96%; Tau2 = 257.32; Chi2 = 94.37; df = 2 (p < 0.00001); test for overall effect, Z = 1.06 (p = 0.29). Riboflavin prior to or with bonding is recommended to improve the bonding of different adhesive systems.
Collapse
Affiliation(s)
- Sumaiya Zabin Eusufzai
- School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu 16150, Malaysia
| | - Aparna Barman
- School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu 16150, Malaysia
| | - Nafij Bin Jamayet
- Restorative Dentistry Division, School of Dentistry, International Medical University Kuala Lumpur, 126, Jalan Jalil Perkasa 19, Wilayah Persekutuan Kuala Lumpur, Bukit Jalil, Kuala Lumpur 57000, Malaysia
| | - Wan Muhamad Amir W Ahmad
- School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu 16150, Malaysia
| | - Syed Sarosh Mahdi
- Division of Clinical Oral Health Sciences, School of Dentistry, International Medical University, Kuala Lumpur 57000, Malaysia
- Faculty of Dentistry, Dalhousie University, 5981 University Ave, Halifax, NS B3H 1W2, Canada
| | - Zeeshan Sheikh
- Faculty of Dentistry, Dalhousie University, 5981 University Ave, Halifax, NS B3H 1W2, Canada
| | - Umer Daood
- Restorative Dentistry Division, School of Dentistry, International Medical University Kuala Lumpur, 126, Jalan Jalil Perkasa 19, Wilayah Persekutuan Kuala Lumpur, Bukit Jalil, Kuala Lumpur 57000, Malaysia
| |
Collapse
|
35
|
Rifane TO, Cordeiro KEM, Silvestre FA, Souza MT, Zanotto ED, Araújo-Neto VG, Giannini M, Sauro S, de Paula DM, Feitosa VP. Impact of silanization of different bioactive glasses in simplified adhesives on degree of conversion, dentin bonding and collagen remineralization. Dent Mater 2023; 39:217-226. [PMID: 36690502 DOI: 10.1016/j.dental.2023.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 12/29/2022] [Accepted: 01/15/2023] [Indexed: 01/22/2023]
Abstract
OBJECTIVE To analyze simplified adhesive containing pure or silanized bioglass 45S5 (with calcium) or Sr-45S5 (strontium-substituted) fillers applied on dentin and to evaluate the microtensile bond strength (µTBS), interface nanoleakage, degree of conversion of adhesive, collagen degradation and remineralization. METHODS Ambar Universal adhesive (FGM) was doped with 10 wt% bioactive glasses to form following groups: Control (no bioglass), 45S5 (conventional bioglass 45S5), Sr-45S5 (Sr-substituted bioglass 45S5), Sil-45S5 (silanized bioglass 45S5) and Sil-Sr-45S5 (silanized bioglass Sr-45S5). Adhesives were applied after dentin acid-etching using phosphoric acid at extracted human molars. Resin-dentin sticks were obtained and tested for µTBS, nanoleakage at 24 h or 6 months. Degree of conversion was measured using micro-Raman spectroscopy. Dentin remineralization was assessed by FTIR after 6-month storage in PBS. Hydroxyproline (HYP) release was surveyed by UV-Vis spectroscopy. Statistical analysis was performed using ANOVA and Tukey's test (p < 0.05). RESULTS Regarding µTBS, Sr-45S5 and 45S5 presented higher and stable results (p > 0.05). Control (p = 0.018) and Sil-Sr-45S5 (p < 0.001) showed µTBS reduction after 6-month aging. Sil-Sr-45S5 showed higher HYP release than that obtained in the 45S5 group. Sil-45S5 showed mineral deposition and increase in µTBS (p = 0.028) after 6-months. All experimental adhesives exhibited higher degree of conversion compared to Control group, except for 45S5. All adhesives created gap-free interfaces, with very low silver impregnation, except for Sil-Sr-45S5. SIGNIFICANCE The incorporation of silanized 45S5 bioglass into the universal adhesive was advantageous in terms of dentin remineralization, bonding performance and adhesive polymerization. Conversely, Sil-Sr-45S5 compromised the µTBS, interface nanoleakage and had a negative impact on HYP outcomes.
Collapse
Affiliation(s)
| | | | | | - Marina Trevelin Souza
- Vitreous Materials Laboratory (LAMAV), Department of Materials Engineering, Federal University of São Carlos, São Carlos, Brazil.
| | - Edgar Dutra Zanotto
- Vitreous Materials Laboratory (LAMAV), Department of Materials Engineering, Federal University of São Carlos, São Carlos, Brazil.
| | - Vitaliano Gomes Araújo-Neto
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.
| | - Marcelo Giannini
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.
| | - Salvatore Sauro
- Department of Biomaterials and Minimally Invasive Dentistry, Cardenal Herreara CEU University, Valencia, Spain.
| | | | | |
Collapse
|
36
|
Wang Y, Ding Y, Deng J, Nie R, Meng X. Antibacterial one-step self-etching dental adhesive with silver nanoparticles synthesized in situ. J Dent 2023; 129:104411. [PMID: 36626977 DOI: 10.1016/j.jdent.2023.104411] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 12/15/2022] [Accepted: 01/03/2023] [Indexed: 01/09/2023] Open
Abstract
OBJECTIVES The objective of this study is to value the long-term antibacterial capability and adhesive properties of one-step self-etching dental adhesive containing silver nanoparticles (AgNPs) synthesized in situ. METHODS One-step self-etching adhesives with various weight percentages of silver 2-ethylhezanoate (0%, 0.05%, 0.10%, and 0.20%) were obtained by in-situ synthesis; the sizes and distribution of the AgNPs in resin were observed. The antibacterial effects of dentin-resin specimens were assessed by various test methods after being aged for 1 week to 1 year. The microtensile bond strength (μTBS) and interfacial nanoleakage (NL) were evaluated using extracted human teeth after being aged for 1 day and 1 year. RESULTS Uniform distribution of AgNPs in resin was observed in all experimental groups, and the average size was 4.71 nm-4.81 nm. All groups containing AgNPs showed significant antibacterial differences from the control group (P<0.05) over the ageing of 1 year. Although the increase of concentration tended to improve antibacterial activity, significant differences were not observed between the 0.10% and 0.20% groups (P>0.05). No significant differences were observed between all experimental groups and the control group in μTBS testing and NL testing at 1-day and 1-year time points (P>0.05). CONCLUSIONS 0.10% AgNPs synthesized in situ might be appropriate to impart a long-term antibacterial ability to the one-step self-etching adhesive, without affecting its adhesive performance. CLINICAL SIGNIFICANCE This study suggests that in-situ synthesis of AgNPs is an effective method to improve the antibacterial ability of dental adhesives with the potential to inhibit secondary caries.
Collapse
Affiliation(s)
- Yichun Wang
- Department of Prosthodontics, Nanjing Stomatological Hospital, Medical School of Nanjing University, #30 Zhongyang Road, Nanjing, Jiangsu 210008, PR. China
| | - Yashuang Ding
- Department of Prosthodontics, Nanjing Stomatological Hospital, Medical School of Nanjing University, #30 Zhongyang Road, Nanjing, Jiangsu 210008, PR. China
| | - Jie Deng
- Department of Emergency&Polyclinic 1st, Nanjing Stomatological Hospital, Medical School of Nanjing University, #30 Zhongyang Road, Nanjing, Jiangsu 210008, PR. China
| | - Rongrong Nie
- Department of Prosthodontics, Nanjing Stomatological Hospital, Medical School of Nanjing University, #30 Zhongyang Road, Nanjing, Jiangsu 210008, PR. China.
| | - Xiangfeng Meng
- Department of Prosthodontic Technology, Nanjing Stomatological Hospital, Medical School of Nanjing University, #30 Zhongyang Road, Nanjing, Jiangsu 210008, PR. China.
| |
Collapse
|
37
|
Effect of Different Application Modalities on the Bonding Performance of Adhesive Systems to Dentin: A Systematic Review and Meta-Analysis. Cells 2023; 12:cells12010190. [PMID: 36611983 PMCID: PMC9818277 DOI: 10.3390/cells12010190] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 12/11/2022] [Accepted: 12/30/2022] [Indexed: 01/05/2023] Open
Abstract
Diverse types of dental adhesives exhibit different cytotoxic outcomes on cells in vitro. Currently, no standard adhesive application technique has so far been decisive for clinicians for better durability of resin-dentin bonds of adhesive systems. The purpose of this study was to systematically review the literature to evaluate the bonding performance of adhesive systems to dentin by using different application modalities. The systematic research strategy was conducted by two reviewers among multiple databases: PubMed, Scopus, Web of Science, Embase, and Scielo. In vitro studies reporting the effects of additional steps for the application of adhesive systems on the bond strength to dentin were selected. Meta-analysis was performed using Review Manager Software version 5.3.5 using the random effects model. The methodological quality of each in vitro study was assessed according to the parameters of a previous systematic review. The electronic research through different databases generated a total of 8318 references. After the examination of titles and abstracts, a total of 106 potentially relevant studies accessed the full-text evaluation phase. After full-text examination, 78 publications were included for the qualitative analysis, and 68 studies were included in the meta-analysis. Regarding the etch-and-rinse adhesive systems, the application modalities that improved the overall bond strength were the application of a hydrophobic resin layer (p = 0.005), an extended application time (p < 0.001), an application assisted by an electric current (p < 0.001), a double-layer application (p = 0.05), the agitation technique (p = 0.02), and the active application of the adhesive (p < 0.001). For self-etch adhesive systems, the techniques that improved the overall bond strength were the application of a hydrophobic resin layer (p < 0.001), an extended application time (p = 0.001), an application assisted by an electric current (p < 0.001), a double-layer application (p < 0.001), the agitation technique (p = 0.01), and the active application of the adhesive (p < 0.001). The in vitro evidence suggests that the application of adhesive systems using alternative techniques or additional strategies may be beneficial for improving their bond strength to dentin. The application modalities that favored the overall bond strength to dentin were an extended application time, a double-layer application, an application assisted by an electric current, the active application of the adhesive, and the application of a hydrophobic resin layer. Worth mentioning is that some techniques are intended to increase the degree of the conversion of the materials, and therefore, improvements in the biocompatibility of the materials can be expected.
Collapse
|
38
|
Somrit P, Tantilertanant Y, Srisawasdi S. Primer application technique and remaining dentin thickness affected microtensile bond strength of contemporary dentin adhesives under simulated pulp pressure. Clin Oral Investig 2023; 27:139-149. [PMID: 36109375 DOI: 10.1007/s00784-022-04699-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 08/26/2022] [Indexed: 01/28/2023]
Abstract
OBJECTIVES To evaluate the effect of application techniques, type of adhesives and remaining dentin thicknesses on microtensile bond strength (µTBS) of 3 adhesive systems. MATERIALS AND METHODS 112 flat occlusal dentinal surfaces of third molar were randomly allocated into 16 groups based on 2 remaining dentin thicknesses (RDT), 2 application techniques, and 3 adhesive systems (Optibond FL, OFL; Clearfil SE Bond, CSE; and Single Bond Universal, SB); SB was applied in either etch-and-rinse (ER) or self-etch (SE) mode. Simulated pulpal pressure was performed during restorative procedure and water storage. The stick-shaped specimens from each tooth underwent µTBS testing. The data were evaluated using a paired t test and ANOVA followed by a post hoc test. The fractured specimens were evaluated for mode of failure using a stereomicroscope. RESULTS The mean µTBS values were significantly affected by RDT, application technique, and types of adhesives. Neither RDT nor application technique affected µTBS of SB in ER mode, whereas application technique affected both conventional and universal self-etch adhesives. RDT also influenced µTBS of OFL. CONCLUSIONS RDT and application technique differently affected the µTBS of dentin bonding which was product-related. Etch-and-rinse systems had higher bond strength to superficial than to deep dentin, whereas self-etch systems were more sensitive to both RDT and application technique. CLINICAL RELEVANCE The universal adhesive is less sensitive to intrinsic wetness and can be used according to manufacturer's instructions.
Collapse
Affiliation(s)
- Paphawee Somrit
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Henri-Dunant Road, Pathumwan, Bangkok, 10330, Thailand.
| | - Yanee Tantilertanant
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Henri-Dunant Road, Pathumwan, Bangkok, 10330, Thailand
| | - Sirivimol Srisawasdi
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Henri-Dunant Road, Pathumwan, Bangkok, 10330, Thailand
| |
Collapse
|
39
|
Bednarczyk P, Irska I, Gziut K, Mozelewska K, Ossowicz-Rupniewska P. Synthesis of Hybrid Epoxy Methacrylate Resin Based on Diglycidyl Ethers and Coatings Preparation via Cationic and Free-Radical Photopolymerization. Int J Mol Sci 2022; 23:ijms232415592. [PMID: 36555232 PMCID: PMC9779419 DOI: 10.3390/ijms232415592] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 11/30/2022] [Accepted: 12/07/2022] [Indexed: 12/13/2022] Open
Abstract
A series of difunctional epoxy methacrylate resins (EAs) containing at least one epoxy and at least one methacrylate group were synthesized by means of an addition reaction between epoxy-terminated diglycidyl ethers and methacrylic acid. In order to investigate the impact of polymer architecture on the course of addition reactions and further coating properties, several different types of diglycidyl ethers, i.e., linear, containing aliphatic or aromatic rings, with a short or polymeric backbone, were employed in the synthesis. The carboxyl-epoxide addition esterification reactions have been found to, in a relatively straightforward manner, control the extent of acrylation depending on the substrate feed ratio and reaction time. The structure of obtained pre-polymers was evaluated by FT-IR and NMR methods. At the same time, the extent of addition reactions was validated via quantitative analysis, including non-volatile matter content (NV), acid value (PAVs), and epoxy equivalent value (EE) analysis. The modification was carried out in a manner likely to create a compound with one epoxy and one carbon-carbon pendant group. Hence, due to the presence of both functionalities, it is possible to crosslink compositions based on synthesized EAs via two distinct mechanisms: (i) cationic polymerization or (ii) free-radical polymerization. Synthesized epoxy methacrylate pre-polymers were further employed for use in formulate photocurable coating compositions by the cationic or radical process. Furthermore, the photopolymerization behavior and properties of cured coatings were explored regarding some structural factors and parameters. The investigated polymeric materials cure in a short time to obtain coatings with good properties, which is why they can be successfully used to produce protective and decorative coatings for many industries.
Collapse
Affiliation(s)
- Paulina Bednarczyk
- Department of Chemical Organic Technology and Polymeric Materials, Faculty of Chemical Technology and Engineering, West Pomeranian University of Technology in Szczecin, Piastów Ave. 42, 71-065 Szczecin, Poland
- Correspondence:
| | - Izabela Irska
- Department of Materials Technology, Faculty of Mechanical Engineering and Mechatronics, West Pomeranian University of Technology in Szczecin, Piastów 19 Avenue, 70-310 Szczecin, Poland
| | - Konrad Gziut
- Department of Chemical Organic Technology and Polymeric Materials, Faculty of Chemical Technology and Engineering, West Pomeranian University of Technology in Szczecin, Piastów Ave. 42, 71-065 Szczecin, Poland
| | - Karolina Mozelewska
- Department of Chemical Organic Technology and Polymeric Materials, Faculty of Chemical Technology and Engineering, West Pomeranian University of Technology in Szczecin, Piastów Ave. 42, 71-065 Szczecin, Poland
| | - Paula Ossowicz-Rupniewska
- Department of Chemical Organic Technology and Polymeric Materials, Faculty of Chemical Technology and Engineering, West Pomeranian University of Technology in Szczecin, Piastów Ave. 42, 71-065 Szczecin, Poland
| |
Collapse
|
40
|
Xu R, Mu X, Hu Z, Jia C, Yang Z, Yang Z, Fan Y, Wang X, Wu Y, Lu X, Chen J, Xiang G, Li H. Enhancing bioactivity and stability of polymer-based material-tissue interface through coupling multiscale interfacial interactions with atomic-thin TiO 2 nanosheets. NANO RESEARCH 2022; 16:5247-5255. [PMID: 36532602 PMCID: PMC9734535 DOI: 10.1007/s12274-022-5153-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 09/30/2022] [Accepted: 10/03/2022] [Indexed: 05/25/2023]
Abstract
Stable and bioactive material-tissue interface (MTF) basically determines the clinical applications of biomaterials in wound healing, sustained drug release, and tissue engineering. Although many inorganic nanomaterials have been widely explored to enhance the stability and bioactivity of polymer-based biomaterials, most are still restricted by their stability and biocompatibility. Here we demonstrate the enhanced bioactivity and stability of polymer-matrix bio-composite through coupling multiscale material-tissue interfacial interactions with atomically thin TiO2 nanosheets. Resin modified with TiO2 nanosheets displays improved mechanical properties, hydrophilicity, and stability. Also, we confirm that this resin can effectively stimulate the adhesion, proliferation, and differentiation into osteogenic and odontogenic lineages of human dental pulp stem cells using in vitro cell-resin interface model. TiO2 nanosheets can also enhance the interaction between demineralized dentinal collagen and resin. Our results suggest an approach to effectively up-regulate the stability and bioactivity of MTFs by designing biocompatible materials at the sub-nanoscale. Electronic Supplementary Material Supplementary material (further details of fabrication and characterization of TiO2 NSs and TiO2-ARCs, the bioactivity evaluation of TiO2-ARCs on hDPSCs, and the measurement of interaction with demineralized dentin collagen) is available in the online version of this article at 10.1007/s12274-022-5153-1.
Collapse
Affiliation(s)
- Rongchen Xu
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, 100853 China
- Department of Stomatology, The Third Medical Center, Chinese PLA General Hospital, Beijing, 100039 China
| | - Xiaodan Mu
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, 100853 China
| | - Zunhan Hu
- Department of Stomatology, Kunming Medical University, Kunming, 650500 China
| | - Chongzhi Jia
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, 100853 China
| | - Zhenyu Yang
- National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an, 710032 China
| | - Zhongliang Yang
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, 100853 China
| | - Yiping Fan
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, 100853 China
| | - Xiaoyu Wang
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, 100853 China
- Department of Stomatology, The Strategic Support Force Medical Center, Beijing, 100101 China
| | - Yuefeng Wu
- State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing, 100029 China
| | - Xiaotong Lu
- State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing, 100029 China
| | - Jihua Chen
- National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an, 710032 China
| | - Guolei Xiang
- State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing, 100029 China
| | - Hongbo Li
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, 100853 China
| |
Collapse
|
41
|
Photoinitiation abilities of indeno- and indoloquinoxaline derivatives and mechanical properties of dental fillings based on multifunctional acrylic monomers and glass ionomer. POLYMER 2022. [DOI: 10.1016/j.polymer.2022.125625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
42
|
Yaghmoor RB, Jamal H, Abed H, Allan E, Ashley P, Young A. Incorporation of MMP inhibitors into dental adhesive systems and bond strength of coronal composite restorations: A systematic review and meta-analysis of in vitro studies. JAPANESE DENTAL SCIENCE REVIEW 2022; 58:298-315. [PMID: 36247748 PMCID: PMC9557023 DOI: 10.1016/j.jdsr.2022.09.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 08/31/2022] [Accepted: 09/22/2022] [Indexed: 10/31/2022] Open
Abstract
Purpose To systematically review in vitro studies that incorporated MMP inhibitors into adhesive systems in terms of the effect on immediate and aged bond strength of dental composite to dentine. Materials and methods Independently, two reviewers conducted an electronic search in three databases (MEDLINE, EMBASE, and Google Scholar) following the Preferred Reporting Items for Systematic Review and Meta-Analyses Protocols (PRISMA-P), up to 6 March 2022. Results The search resulted in 894 papers, 33 of which were eligible to be included in the review; of those, 13 fulfilled the meta-analysis eligibility criteria. Nineteen inhibitors were used among the studies, and those included in the meta-analysis were 2%, 0.2% chlorhexidine (CHX), 5 µM GM1489, and 0.5%, 1% benzalkonium chloride (BAC). In the meta-analysis, while above inhibitors showed no adverse effect on bond strength, 0.2% CHX and 5 µM GM1489 caused a significant increase in immediate and 12-months bond strength. All other inhibitors resulted in a significant increase in bond strength at six months of ageing. Conclusions Incorporation of MMP inhibitors into the adhesive system has no unfavourable effect on immediate bond strength but a favourable effect on longer-term bond strength. Additionally, inhibitors other than CHX could have similar or better effects on bond strength.
Collapse
Affiliation(s)
- Rayan B. Yaghmoor
- Department of Restorative Dentistry, Faculty of Dentistry, Umm Al-Qura University, Makkah 24381, Saudi Arabia
- Department of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, Royal Free Hospital London, NW3 2PF, UK
- Department of Microbial Diseases, UCL Eastman Dental Institute, Royal Free Hospital, London NW3 2PF, UK
- Corresponding author at: Department of Restorative Dentistry, Faculty of Dentistry, Umm Al-Qura University, Makkah 24381, Saudi Arabia.
| | - Hasan Jamal
- Unit of Paediatric Dentistry, UCL Eastman Dental Institute, London WC1E 6DE, UK
| | - Hassan Abed
- Department of Basic and Clinical Oral Sciences, Umm Al-Qura University, Faculty of Dentistry, Makkah 24381, Saudi Arabia
| | - Elaine Allan
- Department of Microbial Diseases, UCL Eastman Dental Institute, Royal Free Hospital, London NW3 2PF, UK
| | - Paul Ashley
- Unit of Paediatric Dentistry, UCL Eastman Dental Institute, London WC1E 6DE, UK
| | - Anne Young
- Department of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, Royal Free Hospital London, NW3 2PF, UK
| |
Collapse
|
43
|
Mazzitelli C, Maravic T, Josic U, Mancuso E, Generali L, Checchi V, Breschi L, Mazzoni A. Effect of adhesive strategy on resin cement bonding to dentin. J ESTHET RESTOR DENT 2022; 35:501-507. [PMID: 36281586 DOI: 10.1111/jerd.12978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 10/01/2022] [Accepted: 10/04/2022] [Indexed: 10/31/2022]
Abstract
OBJECTIVE The cement bonding strategy and the polymerization mode can influence the prognosis of indirect restorations. The microtensile bond strength (μTBS) and dentin endogenous enzymatic activity of a dual-cure resin cement (PV5) used in combination with two dentin surface conditioners (accelerator-enhancer primer, TP or universal adhesive, UA) were evaluated. MATERIALS AND METHODS PV5 was used to lute composite overlays after dentin treatment with TP or UA. The resin cement was self-cured, SC (1 h at 37 °C) or dual-cured, DC (20 s light-cure followed by 15 min self-cure at 37°C). The μTBS test, fractographic analysis, and the in situ zymography evaluations were performed after 24 h (T0 ) or 1 yr (T12 ) of artificial storage. Data were statistically analyzed (α = 0.05). RESULTS TP/DC obtained the highest adhesive strengths (45 ± 9 and 36.6 ± 8), while UA/SC (17 ± 8 and 11 ± 4) the lowest, both at T0 and T12 , respectively. DC resulted in superior bonding values than the SC, independent of the dentin surface treatment (p < 0.05). The type of adhesive, curing mode and aging influenced the gelatinolytic activity (p < 0.05). CONCLUSIONS The dual-cure resin cement used in combination with its accelerator-enhancer primer showed superior bonding performances with respect to universal adhesive. Dual-curing the resin cement was determinant to enhance bonding capability over time, independent of the adhesive strategy. CLINICAL RELEVANCE Clinicians must be aware to faithfully follow manufacturer's recommendation regarding the adhesive strategy suggested with the resin cement used.
Collapse
Affiliation(s)
- Claudia Mazzitelli
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| | - Tatjana Maravic
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| | - Uros Josic
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| | - Edoardo Mancuso
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| | - Luigi Generali
- Department of Surgery, Medicine, Dentistry and Morphological Sciences‐Unit of Dentistry and Oral‐Maxillo‐Facial Surgery University of Modena and Reggio Emilia Modena Italy
| | - Vittorio Checchi
- Department of Surgery, Medicine, Dentistry and Morphological Sciences‐Unit of Dentistry and Oral‐Maxillo‐Facial Surgery University of Modena and Reggio Emilia Modena Italy
| | - Lorenzo Breschi
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| | - Annalisa Mazzoni
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| |
Collapse
|
44
|
Effect of nanocrystalline cellulose/silica-based fillers on mechanical properties of experimental dental adhesive. Polym Bull (Berl) 2022. [DOI: 10.1007/s00289-022-04503-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
45
|
Velho HC, da Rosa LS, Temp RW, Cocco FM, Pereira GKR, May LG, Valandro LF. Adhesive application after ceramic surface treatment is detrimental to load-bearing capacity under fatigue of a lithium disilicate glass-ceramic. J Mech Behav Biomed Mater 2022; 135:105453. [PMID: 36126505 DOI: 10.1016/j.jmbbm.2022.105453] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 08/30/2022] [Accepted: 09/03/2022] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To evaluate whether an adhesive application after surface treatment on a lithium disilicate ceramic (LD) has an influence on its load-bearing capacity under fatigue. METHODS LD discs (Ø= 10 mm; thickness= 1 mm) were allocated into 8 groups (n= 15), considering 3 factors: "ceramic surface treatment" - HF: hydrofluoric acid + universal primer application; or MEP: single-component ceramic primer; "adhesive application" - with or without; and "aging protocol" - baseline: 24 h to 7 days; or aging: 180 days of storage + 25,000 thermal cycles. The LD discs were adhesively bonded to glass fiber-reinforced epoxy resin discs (Ø= 10 mm; thickness= 2 mm) and stored according to the condition and each group. Cyclic fatigue testing (initial load= 100 N; step size= 100 N until600 N and after step size= 25 N to failure; 10,000 cycles/step; 20 Hz frequency) was performed. Fractographic and adhesive interface analyzes were also performed. The collected data were then analyzed by Kaplan Meier and Mantel-Cox tests and One-way ANOVA. RESULTS The adhesive application in the baseline condition had no influence on the load-bearing capacity under fatigue when the HF surface treatment was performed, however, adhesive application for the MEP treatment led to worse results than without it. The adhesive application in the aged condition showed worse fatigue outcomes for both treatments. All specimens presented radial cracks. MEP treatment followed by adhesive application presented the thickest luting layer. CONCLUSION The adhesive application after surface treatments of a lithium disilicate glass-ceramic is detrimental to its load-bearing capacity under fatigue when adhesively luted onto a supporting substrate.
Collapse
Affiliation(s)
- Helder Callegaro Velho
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Renatta Wrasse Temp
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Maidana Cocco
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Liliana Gressler May
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
46
|
Zhou W, Liao ZX, Chen JH, Qiu BY, Zhang Y, Zhang L. Color change of glass ceramic restorations cemented by four types of dual-cured resin luting agents with different initiator systems. Dent Mater J 2022; 41:833-842. [PMID: 35934801 DOI: 10.4012/dmj.2022-044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study aimed to comprehensively evaluate the effect of dual-cured resin luting agents with different initiator systems on the color stability of glass ceramic restorations by simulating various clinical glass ceramic restorations. Three commonly used shades from each of the two dual-cured resin luting agents with an amine-initiation system or without it were studied. The individual specimens had different translucency and thickness and were artificially aged using a xenon light aging machine. The color was measured before and after aging using a digital spectrophotometer with the difference calculated and analyzed statistically. As results, the amine-free dual-cured resin luting agents were more color stable than those using amine-initiation systems for both uncovered and bonding groups. The translucency and thickness of the ceramic, and shade and type of the resin luting agent significantly affected the color stability of glass ceramic restorations.
Collapse
Affiliation(s)
- Wei Zhou
- National Clinical Research Center for Oral Diseases & State Key Laboratory of Military Stomatology & Shaanxi Key Laboratory of Oral Diseases & Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University
| | - Zi-Xuan Liao
- Department of Stomatology, General Hospital of Eastern Theater Command of Chinese People's Liberation Army
| | - Ji-Hua Chen
- National Clinical Research Center for Oral Diseases & State Key Laboratory of Military Stomatology & Shaanxi Key Laboratory of Oral Diseases & Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University
| | - Bi-Ying Qiu
- National Clinical Research Center for Oral Diseases & State Key Laboratory of Military Stomatology & Shaanxi Key Laboratory of Oral Diseases & Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University
| | - Yang Zhang
- Department of Stomatology, The Air Force Hospital from Eastern Theater
| | - Ling Zhang
- National Clinical Research Center for Oral Diseases & State Key Laboratory of Military Stomatology & Shaanxi Key Laboratory of Oral Diseases & Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University
| |
Collapse
|
47
|
Cardenas A, Siqueira F, Nuñez A, Nonato RF, Cavalcanti K, Soares CJ, Reis A, Loguercio AD. Influence of Irradiance and Exposure Times on the Mechanical and Adhesive Properties of Universal Adhesives with Dentin. Oper Dent 2022; 47:412-424. [PMID: 35917253 DOI: 10.2341/21-042-l] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/10/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVES This study evaluated the influence of irradiance/exposure time on the Knoop hardness (KHN) and polymer cross-linking density (PCLD), as well as microtensile bond strength (μTBS), nanoleakage (NL), and in situ degree of conversion (DC) of universal adhesives. METHODS AND MATERIALS Two universal adhesive systems, Clearfil Universal Bond Quick (CUQ) and Scotchbond Universal Adhesive (SBU), were light-cured using various irradiance/exposure times: 1400 mW/cm2 for 5 s (1400*5); 1400 mW/cm2 for 10 s (1400*10); 3200 mW/cm2 for 5 s (3200*5); and 3200 mW/cm2 for 10 s (3200*10). Adhesive disks from each group were used to measure PCLD by KHN. One hundred and twenty-eight human molars were randomly assigned to 16 groups according to the following variables: adhesive system vs adhesive strategies vs radiance/exposure times. After restoration, specimens were sectioned into resin-dentin sticks and tested for μTBS, NL, and DC. The data from PCLD (%), KHN, μTBS (MPa), NL (%), and DC (%) data were subjected to ANOVA and Tukey's test (α=0.05). RESULTS Significant reductions in KHN, μTBS, and DC (p=0.00001) values and an increase in NL and PCLD (p=0.00001) values were observed for 3200*10 when compared with other groups. Higher KHN, μTBS, and DC (p=0.000001) values were observed for 3200*5 in comparison with the other groups. The 1400*5 (7 J/cm2) and 1400*10 (14 J/cm2) groups showed intermediate values (p=0.000001). CONCLUSION Although similar results in terms of hardness, polymer cross-linking density and nanoleakage were observed when 5 seconds at 3200 mW/cm2 and 10 seconds at 1400 mW/cm2 groups were compared, the use of higher irradiance (3200 mW/cm2) for only 5 seconds showed better results in terms of bond strength and degree of conversion for both universal adhesives to dentin. The prolonged exposure time (10 seconds) at the higher irradiance (3200 mW/cm2) showed the worst results.
Collapse
Affiliation(s)
- Afm Cardenas
- Andres Felipe Millan Cardenas, DDS, Ms, PhD, professor, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Fsf Siqueira
- Fabiana Suelen Figuerêdo de Siqueira, DDS, Ms, PhD, professor, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - A Nuñez
- Alejandra Nuñez, DDS, Ms, PhD student, Department of Restorative Dentistry, Ponta Grossa State University, Ponta Grossa, Paraná, Brazil, and Professor, Department of Restorative Dentistry and Biomaterials, San Francisco de Quito University, Quito, Ecuador
| | - R F Nonato
- Rammon de Faria Nonato, DDS, Ms student, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Kgba Cavalcanti
- Karoline Guará Brusaca Almeida Cavalcanti, DDS, Ms, PhD student, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - C J Soares
- Carlos José Soares, DDS, Ms, PhD, professor, Departament of Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil, and Dental School, Department of Operative Dentistry and Dental Materials, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - A Reis
- *Alessandra Reis, DDS, PhD, professor, Department of Restorative Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | - A D Loguercio
- Alessandro D. Loguercio, DDS, Ms, PhD, professor, Department of Restorative Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| |
Collapse
|
48
|
Monteiro LC, Pecorari VGA, Gontijo IG, Marchi GM, Lima DANL, Aguiar FHB. PEEK and fiberglass intra-radicular posts: influence of resin cement and mechanical cycling on push-out bond strength. Clin Oral Investig 2022; 26:6907-6916. [PMID: 35881239 DOI: 10.1007/s00784-022-04645-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Accepted: 07/12/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To evaluate the bond strength of four types of posts (pre-fabricated fiberglass post, fiberglass post anatomized with composite resin, milled fiberglass post, and milled polyetheretherketone (PEEK) post), and two types of resin cements (conventional and self-adhesive) by assessing immediate bond strength and post-mechanical aging at each root third. MATERIALS AND METHODS Bovine endodontically treated roots (16 groups, n = 8) were prepared and the posts were produced and luted; the specimens of aging groups were cycled (300,000 cycles under 50 N load at 1.2 Hz frequency); six slices of each root were obtained; push-out test was performed by using a universal testing machine (500 N load at 1 mm/min cross speed); fracture pattern was classified into five levels. The statistical analyses used were three-way ANOVA, Tukey's test (for bond strength), and Fisher's test (for fracture pattern) (α < 0.05). RESULTS Differences were found between the cements for posts (conventional: p < 0.001; self-adhesive: p = 0.002), whereas no difference was found for root region (p = 0.941; p = 0.056, respectively); analysis of each root showed significant differences for cements (p < 0.001), posts (p < 0.001), and mechanical cycling (p = 0.001); in terms of double interaction, differences were found for posts and mechanical cycling (p = 0.005); no other interactions were observed (double or triple); the fracture pattern showed difference between the groups for both cements. CONCLUSIONS Milled PEEK posts seem to be a good clinical option, but they require improvement of CAD-CAM technology and advances towards their adhesion. CLINICAL RELEVANCE Milled posts are promising and can reduce clinical time for rehabilitation of extensively destroyed teeth.
Collapse
Affiliation(s)
- Lara Christie Monteiro
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Bairro Areão13.414-093, Piracicaba, SP, Brazil.
| | | | - Isabela Guerra Gontijo
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Bairro Areão13.414-093, Piracicaba, SP, Brazil
| | - Giselle Maria Marchi
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Bairro Areão13.414-093, Piracicaba, SP, Brazil
| | - Débora Alves Nunes Leite Lima
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Bairro Areão13.414-093, Piracicaba, SP, Brazil
| | - Flávio Henrique Baggio Aguiar
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Bairro Areão13.414-093, Piracicaba, SP, Brazil
| |
Collapse
|
49
|
Finite element and in vitro study on biomechanical behavior of endodontically treated premolars restored with direct or indirect composite restorations. Sci Rep 2022; 12:12671. [PMID: 35879388 PMCID: PMC9314407 DOI: 10.1038/s41598-022-16480-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 07/11/2022] [Indexed: 11/08/2022] Open
Abstract
Objectives of the study were to investigate biomechanical properties of severely compromised premolars restored with composite restorations using finite element analysis (FEA), and in vitro fracture resistance test. A 3-D model of an endodontically treated premolar was created in Solidworks. Different composite restorations were modelled (direct restoration-DR; endo-crown-EC; post, core, and crown-C) with two different supporting tissues: periodontal ligament/alveolar bone (B), and polymethyl methacrylate (PMMA). Models were two-point axially loaded occlusally (850 N). Von Mises stresses and strains were calculated. The same groups were further tested for static fracture resistance in vitro (n = 5, 6.0 mm-diameter ball indenter, vertical load). Fracture resistance data were statistically analyzed (p < 0.050). The highest stresses and strains in all FEA models were observed on occlusal and vestibular cervical surfaces, corresponding to fracture propagation demonstrated in vitro. C showed the lowest stress in dentin, while EC showed lower stresses and strains in crown cement. B models demonstrated larger high stress areas in the root than PMMA models. No significant differences in fracture resistance (N) were observed between groups (DR: 747.7 ± 164.0, EC: 867.3 ± 108.1, C: 866.9 ± 126.3; p = 0.307). More conservative restorations seem a feasible alternative for endodontically treated premolars to conventional post-core-crown.
Collapse
|
50
|
Maucoski C, Price RB, Arrais CA, Sullivan B. Power output from 12 brands of contemporary LED light-curing units measured using 2 brands of radiometers. PLoS One 2022; 17:e0267359. [PMID: 35802759 PMCID: PMC9269870 DOI: 10.1371/journal.pone.0267359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 04/06/2022] [Indexed: 11/18/2022] Open
Abstract
Background Given the increasing use of photo-activated resins in dentistry, dentists and researchers need a user-friendly dental radiometer to measure the power output from dental light-curing units (LCUs). Objective Our goal was to measure the accuracy of two brands of dental radiometers in reporting the power (mW) from twelve brands of contemporary LCUs compared to a ‘gold standard’ (GS) reference value obtained from an integrating sphere attached to a fiberoptic spectroradiometer. Methods The power output was measured from two units of 12 brands of LCUs, five times on the ‘‘GS” system, five times on two Bluephase Meter II dental radiometers, and five times on two Mini Gig hand-held spectroradiometers. The emission spectrum was also recorded using the ‘GS’ integrating sphere. The power values reported by each meter were subjected to t-tests to compare the two examples of each LCU, and 3-way ANOVA followed by Bonferroni’s post-hoc tests. Regression analyses were also performed to determine the relationship between the data from the hand-held radiometers and the ‘GS’ integrating sphere. Results There was a large difference in the power values (mW) and the emission spectra from the 12 brands of LCUs on their standard-settings (p<0.001). Except for one LCU (Dental Spark @ 15.1%), the differences between the two LCUs of the same brand were less than 5.3% when measured using the ‘GS’ integrating sphere. Regression analyses showed a highly significant agreement between the power values reported from the two brands of radiometers and the ‘GS’ integrating sphere (R2 > 98%). Conclusion We concluded that the power values reported from both brands of dental radiometers we tested were accurate, provided that the light source did not emit wavelengths of light that were beyond the radiometer’s detection limit.
Collapse
Affiliation(s)
- Cristiane Maucoski
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil
| | - Richard B. Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
- * E-mail:
| | - Cesar A. Arrais
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil
| | - Braden Sullivan
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| |
Collapse
|