1
|
Glans A, Wilén J, Hansson B, Audulv Å, Lindgren L. Managing acoustic noise within MRI: A qualitative interview study among Swedish radiographers. Radiography (Lond) 2024; 30:889-895. [PMID: 38603992 DOI: 10.1016/j.radi.2024.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 03/22/2024] [Accepted: 04/01/2024] [Indexed: 04/13/2024]
Abstract
INTRODUCTION Acoustic noise from magnetic resonance imaging (MRI) can cause hearing loss and needs to be mitigated to ensure the safety of patients and personnel. Capturing MR personnel's insights is crucial for guiding the development and future applications of noise-reduction technology. This study aimed to explore how MR radiographers manage acoustic noise in clinical MR settings. METHODS Using a qualitative design, we conducted semi-structured individual interviews with fifteen MR radiographers from fifteen hospitals around Sweden. We focused on the clinical implications of participants' noise management, using an interpretive description approach. We also identified sociotechnical interactions between People, Environment, Tools, and Tasks (PETT) by adopting a Human Factors/Ergonomics framework. Interview data were analyzed inductively with thematic analysis (Braun and Clarke). RESULTS The analysis generated three main themes regarding MR radiographers' noise management: (I) Navigating Occupational Noise: Risk Management and Adaptation; (II) Protecting the Patient and Serving the Exam, and (III) Establishing a Safe Healthcare Environment with Organizational Support. CONCLUSION This study offers insights into radiographers' experiences of managing acoustic noise within MRI, and the associated challenges. Radiographers have adopted multiple strategies to protect patients and themselves from adverse noise-related effects. However, they require tools and support to manage this effectively, suggesting a need for organizations to adopt more proactive, holistic approaches to safety initiatives. IMPLICATIONS FOR PRACTICE The radiographers stressed the importance of a soundproofed work environment to minimize occupational adverse health effects and preserve work performance. They acknowledge noise as a common contributor to patient distress and discomfort. Providing options like earplugs, headphones, mold putty, software-optimized "quiet" sequences, and patient information were important tools. Fostering a safety culture requires proactive safety efforts and support from colleagues and management.
Collapse
Affiliation(s)
- A Glans
- Department of Nursing, Umeå University, Umeå, Sweden; Department of Diagnostics and Intervention, Radiation Physics, Umeå University, Umeå, Sweden.
| | - J Wilén
- Department of Diagnostics and Intervention, Radiation Physics, Umeå University, Umeå, Sweden
| | - B Hansson
- Department of Clinical Sciences Lund, Diagnostic Radiology, Lund University, Lund, Sweden
| | - Å Audulv
- Department of Nursing, Umeå University, Umeå, Sweden
| | - L Lindgren
- Department of Nursing, Umeå University, Umeå, Sweden
| |
Collapse
|
2
|
Radiographers' awareness level of MRI-induced vertigo and their perspectives on the post-examination care provided to patients in Saudi Arabia. J Med Imaging Radiat Sci 2022; 53:633-639. [PMID: 36163238 DOI: 10.1016/j.jmir.2022.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 08/29/2022] [Accepted: 09/01/2022] [Indexed: 12/24/2022]
Abstract
INTRODUCTION Vertigo has been reported by operators and patients during magnetic resonance imaging (MRI) examinations and found to increase in severity as the strength of the scanner magnet increases. This study examined a cohort of MRI radiographers' awareness of MRI-induced vertigo and their perspectives on post-MRI care. METHODS This cross-sectional study used a web-based survey distributed to 110 radiographers. The 18-item survey included questions to elicit demographic information, MRI radiographers' awareness of MRI-induced vertigo, and their perspectives on the post-MRI care that should be provided to patients. Responses were collected between June 2021 and January 2022. The collected data were analyzed using SPSS, version 27. RESULTS A total of 110 MRI radiographers completed the survey. Participants were predominantly male (64.5 %) and working in public practice (91.8 %). Almost all the radiographers were aware of MRI-induced vertigo. About two-thirds of participants knew patients needed assistance off the couch. Nearly all participants knew patients should be asked about their experience with MRI-induced vertigo after their procedures. There were statistically significant associations between the size of magnetic field strength used by the participants and their appreciation of the needed support for patients post-MRI examinations (p= 0.012). CONCLUSION This study provides the first insight into Saudi Arabian MRI radiographers' awareness and perceptions of MRI-induced vertigo. Radiographers were largely aware of MRI-induced vertigo and the supportive care they were supposed to provide their patients. IMPLICATIONS FOR PRACTICE The current study points to a need for training to expand awareness levels of MRI-induced vertigo among a few Saudi MRI radiographers.
Collapse
|
3
|
Glans A, Wilén J, Lindgren L, Björkman-Burtscher IM, Hansson B. Health effects related to exposure of static magnetic fields and acoustic noise-comparison between MR and CT radiographers. Eur Radiol 2022; 32:7896-7909. [PMID: 35674823 PMCID: PMC9668766 DOI: 10.1007/s00330-022-08843-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 04/21/2022] [Accepted: 04/25/2022] [Indexed: 01/03/2023]
Abstract
OBJECTIVES We explored the prevalence of health complaints subjectively associated with static magnetic field (SMF) and acoustic noise exposure among MR radiographers in Sweden, using CT radiographers as a control group. Additionally, we explored radiographers' use of strategies to mitigate adverse health effects. METHODS A cross-sectional survey was sent to all hospitals with MR units in Sweden. MR and/or CT personnel reported prevalence and attribution of symptoms (vertigo/dizziness, nausea, metallic taste, illusion of movement, ringing sensations/tinnitus, headache, unusual drowsiness/tiredness, forgetfulness, difficulties concentrating, and difficulties sleeping) within the last year. We used logistic regression to test associations between sex, age, stress, SMF strength, working hours, and symptom prevalence. Data regarding hearing function, work-environmental noise, and strategies to mitigate adverse symptoms were also analysed. RESULTS In total, 529 out of 546 respondents from 86 hospitals were eligible for participation. A ≥ 20 working hours/week/modality cut-off rendered 342 participants grouped into CT (n = 75), MR (n = 121), or mixed personnel (n = 146). No significant differences in symptom prevalence were seen between groups. Working at ≥ 3T increased SMF-associated symptoms as compared with working at ≤ 1.5T (OR: 2.03, CI95: 1.05-3.93). Stress was a significant confounder. Work-related noise was rated as more troublesome by CT than MR personnel (p < 0.01). MR personnel tended to use more strategies to mitigate adverse symptoms. CONCLUSION No significant differences in symptom prevalence were seen between MR and CT radiographers. However, working at 3T increased the risk of SMF symptoms, and stress increased adverse health effects. Noise nuisance was considered more problematic by CT than MR personnel. KEY POINTS • No significant differences in symptom prevalence were seen between MR and CT radiographers. • Working at ≥ 3 T doubled the odds of experiencing SMF symptoms (vertigo/dizziness, nausea, metallic taste, and/or illusion of movement) as compared to working exclusively at ≤ 1.5 T. • Work-related acoustic noise was less well mitigated and was rated as more troublesome by CT personnel than by MR personnel.
Collapse
Affiliation(s)
- Anton Glans
- Department of Nursing, Umeå University, Umeå, Sweden.
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden.
| | - Jonna Wilén
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | | | - Isabella M Björkman-Burtscher
- Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Radiology, Sahlgrenska University Hospital, Västra Götalands Region, Gothenburg, Sweden
| | - Boel Hansson
- Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
- Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
4
|
Rathebe PC. Subjective symptoms of SMFs and RF energy, and risk perception among staff working with MR scanners within two public hospitals in South Africa. Electromagn Biol Med 2022; 41:152-162. [PMID: 35139718 DOI: 10.1080/15368378.2022.2031212] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
This study assessed subjective symptoms associated with exposure to static magnetic fields (SMFs) and radiofrequency (RF) energy, and perceived safety risk of scanners among magnetic resonance (MR) staff working in the 1.5 and 3 T MRI units. A questionnaire survey was completed by 77 clinical imaging staff working in two hospitals (A and B) in the Mangaung metropolitan region. 50 participants working with the MR scanners were regarded as exposed group and 27 participants from CT scan and X-ray departments were classified as control group. The study comprised 57% females and 43% male participants with an average MRI experience of 5.4 years. Using logistic regression, tinnitus was significantly different between various job titles (p< .034) and it was reported more often (OR 8:00; CI 1.51, 15.17) by those who worked on a 3 T scanner. Increased years of MRI experience was a significant predictor of headache (p< .05), and reporting of nausea was significantly different between various job titles (p < .01). There was an increased risks of reporting vertigo often among female participants (OR: 4.43; CI 0.91, 21.47), those with 5-15 years of MRI experience (OR: 2.09; CI 0.47, 9.34), and those with a light to moderate workload (OR: 2.70; CI 0.49, 14.86). Using linear regression, presence in zone IV during image acquisitioning was the only significant predictor for the sensation of glowing (p < .000). Movement of head/ upper body in the scanner bore was a significant predictor of nausea (p< .026), vertigo (p< .014), instability when standing (p< .014), and a metallic taste (p< .031). There was no correlation between reporting of symptoms and perceived risk of scanners. However, shift duration (rs = 0.576), movement of head/upper body in the scanner bore (rs = 0.424), and strength of the scanners (rs = 0.299) were significantly correlated with perceived risk of scanners. MRI safety training and a comprehensive occupational health and safety program are necessary.
Collapse
Affiliation(s)
- Phoka C Rathebe
- Department of Environmental Health, Faculty of Health Sciences, Doornfontein Campus, University of Johannesburg, Johannesburg, P.O. Box 524 South Africa
| |
Collapse
|
5
|
Sklinda K, Karpowicz J, Stępniewski A. Electromagnetic Exposure of Personnel Involved in Cardiac MRI Examinations in 1.5T, 3T and 7T Scanners. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 19:ijerph19010076. [PMID: 35010336 PMCID: PMC8751149 DOI: 10.3390/ijerph19010076] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Revised: 12/12/2021] [Accepted: 12/13/2021] [Indexed: 12/15/2022]
Abstract
(1) Background: It has been hypothesised that a significant increase in the use of cardiac magnetic resonance (CMR), for example, when examining COVID-19 convalescents using magnetic resonance imaging (MRI), has an influence the exposure profiles of medical personnel to static magnetic fields (STmf). (2) Methods: Static exposure to STmf (SEmf) was recorded during activities that modelled performing CMR by radiographers. The motion-induced time variability of that exposure (TVEmf) was calculated from SEmf samples. The results were compared with: (i) labour law requirements; (ii) the distribution of vertigo perception probability near MRI magnets; and (iii) the exposure profile when actually performing a head MRI. (3) Results: The exposure profiles of personnel managing 42 CMR scans (modelled using medium (1.5T), high (3T) and ultrahigh (7T) field scanners) were significantly different than when managing a head MRI. The majority of SEmf and TVEmf samples (up to the 95th percentile) were at low vertigo perception probability (SEmf < 500 mT, TVEmf < 600 mT/s), but a small fraction were at medium/high levels; (4) Conclusion: Even under the “normal working conditions” defined for SEmf (STmf < 2T) by labour legislation (Directive 2013/35/EC), increased CMR usage increases vertigo-related hazards experienced by MRI personnel (a re-evaluation of electromagnetic safety hazards is suggested in the case of these or similar changes in work organisation).
Collapse
Affiliation(s)
- Katarzyna Sklinda
- Department of Radiology, Centre of Postgraduate Medical Education, Marymoncka 99/103, 01-813 Warszawa, Poland;
| | - Jolanta Karpowicz
- Department of Bioelectromagnetics, Central Institute for Labour Protection–National Research Institute (CIOP-PIB), Czerniakowska 16, 00-701 Warszawa, Poland
- Correspondence: ; Tel.: +48-226-234-650
| | - Andrzej Stępniewski
- ECOTECH-COMPLEX Centre, University of Maria Curie-Skłodowska, Głęboka 39, 20-612 Lublin, Poland;
| |
Collapse
|
6
|
Bravo G, Modenese A, Arcangeli G, Bertoldi C, Camisa V, Corona G, Giglioli S, Ligabue G, Moccaldi R, Mucci N, Muscatello M, Venturelli I, Vimercati L, Zaffina S, Zanotti G, Gobba F. Subjective Symptoms in Magnetic Resonance Imaging Personnel: A Multi-Center Study in Italy. Front Public Health 2021; 9:699675. [PMID: 34692618 PMCID: PMC8530375 DOI: 10.3389/fpubh.2021.699675] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Accepted: 08/26/2021] [Indexed: 12/23/2022] Open
Abstract
Introduction: Magnetic Resonance Imaging (MRI) personnel have significant exposure to static and low-frequency time-varying magnetic fields. In these workers an increased prevalence of different subjective symptoms has been observed. The aim of our study was to investigate the prevalence of non-specific subjective symptoms and of "core symptoms" in a group of MRI personnel working in different centers in Italy, and of possible relationships with personal and occupational characteristics. Methods: The occurrence of 11 subjective symptoms was evaluated using a specific questionnaire with 240 subjects working in 6 different Italian hospitals and research centers, 177 MRI health care and research personnel and 63 unexposed subjects employed in the same departments. Exposure was subjectively investigated according to the type of MRI scanner (≤1.5 vs. ≥3 T) and to the number of MRI procedures attended and/or performed by the personnel, even if no information on how frequently the personnel entered the scanner room was collected. The possible associations among symptoms and estimated EMF exposure, the main characteristics of the population, and job stress perception were analyzed. Results: Eighty-six percent of the personnel reported at least one symptom; drowsiness, headache, and sleep disorders were the most frequent. The total number of symptoms did not differ between exposed persons and controls. Considering the total number of annual MRI procedures reported by the personnel, no significant associations were found nor with the total number of symptoms, nor with "core symptoms." Only subjects complaining of drowsiness also reported a significantly higher mean annual number of MRI procedures with ≤ 1.5 T scanners when compared with exposed subjects without drowsiness. In a multivariate model, subjects with a high level of perceived stress complained of more symptoms (p = 0.0002). Conclusions: Our study did not show any association between the occurrence of reversible subjective symptoms, including the more specific "core symptoms," and the occupational exposure of MRI personnel to static and low-frequency time-varying magnetic fields. On the other hand, the role played by occupational stress appears to be not negligible. In further research in this field, measurements of EMF exposure should be considered.
Collapse
Affiliation(s)
- Giulia Bravo
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
- Department of Medicine, University of Udine, Udine, Italy
| | - Alberto Modenese
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| | - Giulio Arcangeli
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Chiara Bertoldi
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| | - Vincenzo Camisa
- Occupational Medicine Unit, Bambino Gesù Children's Hospital—IRCCS, Rome, Italy
| | - Gianluca Corona
- Health Surveillance Service, University Hospital Policlinico, Modena, Italy
| | - Senio Giglioli
- Occupational Medicine Unit, Azienda Usl Toscana Sud-Est, Siena, Italy
| | - Guido Ligabue
- Health Surveillance Service, University Hospital Policlinico, Modena, Italy
- Chair of Radiology, University of Modena and Reggio Emilia, Modena, Italy
| | - Roberto Moccaldi
- Prevention and Protection Service, National Research Council, Rome, Italy
| | - Nicola Mucci
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Martina Muscatello
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| | - Irene Venturelli
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| | - Luigi Vimercati
- Interdisciplinary Department of Medicine, Occupational Medicine “B. Ramazzini” Unit, University of Bari, Bari, Italy
| | - Salvatore Zaffina
- Occupational Medicine Unit, Bambino Gesù Children's Hospital—IRCCS, Rome, Italy
| | - Giulio Zanotti
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| | - Fabriziomaria Gobba
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| |
Collapse
|
7
|
Hartwig V, Virgili G, Mattei FE, Biagini C, Romeo S, Zeni O, Scarfì MR, Massa R, Campanella F, Landini L, Gobba F, Modenese A, Giovannetti G. Occupational exposure to electromagnetic fields in magnetic resonance environment: an update on regulation, exposure assessment techniques, health risk evaluation, and surveillance. Med Biol Eng Comput 2021; 60:297-320. [PMID: 34586563 DOI: 10.1007/s11517-021-02435-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 08/27/2021] [Indexed: 12/15/2022]
Abstract
Magnetic resonance imaging (MRI) is one of the most-used diagnostic imaging methods worldwide. There are ∼50,000 MRI scanners worldwide each of which involves a minimum of five workers from different disciplines who spend their working days around MRI scanners. This review analyzes the state of the art of literature about the several aspects of the occupational exposure to electromagnetic fields (EMF) in MRI: regulations, literature studies on biological effects, and health surveillance are addressed here in detail, along with a summary of the main approaches for exposure assessment. The original research papers published from 2013 to 2021 in international peer-reviewed journals, in the English language, are analyzed, together with documents published by legislative bodies. The key points for each topic are identified and described together with useful tips for precise safeguarding of MRI operators, in terms of exposure assessment, studies on biological effects, and health surveillance.
Collapse
Affiliation(s)
- Valentina Hartwig
- Institute of Clinical Physiology (IFC), Italian National Research Council (CNR), Via G. Moruzzi 1, 56124, Pisa, San Cataldo, Italy.
| | - Giorgio Virgili
- Virgili Giorgio, Via G. Pastore 2, 26040, Crespina-Lorenzana, Italy
| | - F Ederica Mattei
- West Systems S.R.L, Via Don Mazzolari 25, 56025, Pontedera, PI, Italy
| | - Cristiano Biagini
- Associazione Italiana Tecnici Dell'Imaging in Risonanza Magnetica, AITIRM, Via XX Settembre 76, 50129, Florence, Italy
| | - Stefania Romeo
- Institute for Electromagnetic Sensing of the Environment (IREA) , Italian National Research Council (CNR), Via Diocleziano 328, 80124, Naples, Italy
| | - Olga Zeni
- Institute for Electromagnetic Sensing of the Environment (IREA) , Italian National Research Council (CNR), Via Diocleziano 328, 80124, Naples, Italy
| | - Maria Rosaria Scarfì
- Institute for Electromagnetic Sensing of the Environment (IREA) , Italian National Research Council (CNR), Via Diocleziano 328, 80124, Naples, Italy
| | - Rita Massa
- Institute for Electromagnetic Sensing of the Environment (IREA) , Italian National Research Council (CNR), Via Diocleziano 328, 80124, Naples, Italy.,Department of Physics, University Federico II, Via Cinthia 21, 80126, Naples, Italy
| | - Francesco Campanella
- Dipartimento di medicina, epidemiologia, Igiene del Lavoro E Ambientale, Inail, Via Fontana Candida 1, 00078 Monte Porzio Catone, Rome, Italy
| | - Luigi Landini
- Fondazione Toscana "G. Monasterio", Via G. Moruzzi 1, 56124, Pisa, San Cataldo, Italy
| | - Fabriziomaria Gobba
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Via Campi 287, 41125, Modena, Italy
| | - Alberto Modenese
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Via Campi 287, 41125, Modena, Italy
| | - Giulio Giovannetti
- Institute of Clinical Physiology (IFC), Italian National Research Council (CNR), Via G. Moruzzi 1, 56124, Pisa, San Cataldo, Italy
| |
Collapse
|
8
|
Modenese A, Gobba F. Occupational Exposure to Electromagnetic Fields and Health Surveillance According to the European Directive 2013/35/EU. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:1730. [PMID: 33579004 PMCID: PMC7916781 DOI: 10.3390/ijerph18041730] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/31/2021] [Accepted: 02/04/2021] [Indexed: 12/12/2022]
Abstract
In the European Union, health surveillance (HS) of electromagnetic fields (EMF)-exposed workers is mandatory according to the Directive 2013/35/EU, aimed at the prevention of known direct biophysical effects and indirect EMF's effects. Long-term effects are not addressed in the Directive as the evidence of a causal relationship is considered inadequate. Objectives of HS are the prevention or early detection of EMF adverse effects, but scant evidence is hitherto available on the specific procedures. A first issue is that no specific laboratory tests or medical investigations have been demonstrated as useful for exposure monitoring and/or prevention of the effects. Another problem is the existence of workers at particular risk (WPR), i.e., subjects with specific conditions inducing an increased susceptibility to the EMF-related risk (e.g., workers with active medical devices or other conditions); exposures within the occupational exposure limit values (ELVs) are usually adequately protective against EMF's effects, but lower exposures can possibly induce a health risk in WPR. Consequently, the HS of EMF-exposed workers according to the EU Directive should be aimed at the early detection and monitoring of the recognized adverse effects, as well as an early identification of WPR for the adoption of adequate preventive measures.
Collapse
Affiliation(s)
| | - Fabriziomaria Gobba
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 41125 Modena, Italy;
| |
Collapse
|
9
|
Exposure levels of radiofrequency magnetic fields and static magnetic fields in 1.5 and 3.0 T MRI units. SN APPLIED SCIENCES 2021. [DOI: 10.1007/s42452-021-04178-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
AbstractMagnetic resonance imaging (MRI) staff is exposed to a complex mixture of electromagnetic fields from MRI units. Exposure to these fields results in the development of transient exposure-related symptoms. This study aimed to investigate the exposure levels of radiofrequency (RF) magnetic fields and static magnetic fields (SMFs) from 1.5 and 3.0 T MRI scanners in two public hospitals in the Mangaung Metropolitan region, South Africa. The exposure levels of SMFs and RF magnetic fields were measured using the THM1176 3-Axis hall magnetometer and TM-196 3 Axis RF field strength meter, respectively. Measurements were collected at a distance of 1 m (m) and 2 m from the gantry for SMFs when the brain, cervical spine and extremities were scanned. Measurements for RF magnetic fields were collected at a distance of 1 m with an average scan duration of six minutes. Friedman’s test was used to compared exposure mean values from two 1.5 T scanners, and Wilcoxon test with Bonferroni adjustment was used to identify where the difference between exist. The Shapiro–Wilk test was also used to test for normality between exposure levels in 1.5 and 3.0 T scanners. The measured peak values for SMFs from the 3.0 T scanner at hospital A were 1300 milliTesla (mT) and 726 mT from 1.5 T scanner in hospital B. The difference in terms of SMFs exposure levels was observed between two 1.5 T scanners at a distance of 2 m. The difference between 1.5 T scanners at 1 m was also observed during repeated measurements when brain, cervical spine and extremities scans were performed. Scanners’ configurations, magnet type, clinical setting and location were identified as factors that could influence different propagation of SMFs between scanners of the same nominal B0. The RF pulse design, sequence setting flip-angle and scans performed influenced the measured RF magnetic fields. Three scanners were complaint with occupational exposure guidelines stipulated by the ICNIRP; however, peak levels that exist at 1 m could be managed through adoption of occupational health and safety programs.
Collapse
|
10
|
Hartwig V, Biagini C, De Marchi D, Flori A, Gabellieri C, Virgili G, Ferrante Vero LF, Landini L, Vanello N, Giovannetti G. The Procedure for Quantitative Characterization and Analysis of Magnetic Fields in Magnetic Resonance Sites for Protection of Workers: A Pilot Study. Ann Work Expo Health 2020; 63:328-336. [PMID: 30852618 DOI: 10.1093/annweh/wxz002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Revised: 12/20/2018] [Accepted: 01/09/2019] [Indexed: 11/14/2022] Open
Abstract
Concerning the occupational exposure in magnetic resonance imaging (MRI) facilities, the worker behavior in the magnetic resonance (MR) room is of such particular importance that there is the need for a simple but reliable method to alert the worker of the highest magnetic field exposure. Here, we describe a quantitative analysis of occupational exposure in different MRI working environments: in particular, we present a field measurement method integrated with a software tool for an accurate mapping of the fringe field in the proximity of the magnetic resonance bore. Three illustrative assessment studies are finally presented, compared and discussed, considering an example of a realistic path followed by an MRI worker during the daily procedure. The results show that the basic restrictions set by ICNIRP can be exceeded during standard procedure even in 1.5 T scanners. Using the described simplified metrics, it is possible to introduce behavioral rules on how to move around an MRI room that could be more useful than a numerical limit to aid magnetic field risk mitigation strategies.
Collapse
Affiliation(s)
- Valentina Hartwig
- Institute of Clinical Physiology, CNR, Via G. Moruzzi 1, San Cataldo, Pisa, Italy
| | - Cristiano Biagini
- Associazione Italiana Tecnici dell'Imaging in Risonanza Magnetica, AITIRM, Via XX Settembre 76, Firenze, Italy
| | - Daniele De Marchi
- Associazione Italiana Tecnici dell'Imaging in Risonanza Magnetica, AITIRM, Via XX Settembre 76, Firenze, Italy.,Fondazione CNR-Regione Toscana ''G. Monasterio'', Via G. Moruzzi 1, San Cataldo, Pisa, Italy
| | - Alessandra Flori
- Fondazione CNR-Regione Toscana ''G. Monasterio'', Via G. Moruzzi 1, San Cataldo, Pisa, Italy
| | - Chiara Gabellieri
- Ambulatori Della Misericordia Srl Impresa Sociale, Via Montalvo 8, Campi Bisenzio (FI), Italy
| | | | | | - Luigi Landini
- Fondazione CNR-Regione Toscana ''G. Monasterio'', Via G. Moruzzi 1, San Cataldo, Pisa, Italy.,Department of Information Engineering, University of Pisa, Via G. Caruso 16, Pisa, Italy
| | - Nicola Vanello
- Department of Information Engineering, University of Pisa, Via G. Caruso 16, Pisa, Italy
| | - Giulio Giovannetti
- Institute of Clinical Physiology, CNR, Via G. Moruzzi 1, San Cataldo, Pisa, Italy
| |
Collapse
|
11
|
A health and safety model for occupational exposure to radiofrequency fields and static magnetic fields from 1.5 and 3 T MRI scanners. HEALTH AND TECHNOLOGY 2020. [DOI: 10.1007/s12553-019-00379-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
12
|
Hansson Mild K, Lundström R, Wilén J. Non-Ionizing Radiation in Swedish Health Care-Exposure and Safety Aspects. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E1186. [PMID: 30987016 PMCID: PMC6479478 DOI: 10.3390/ijerph16071186] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 03/26/2019] [Accepted: 03/28/2019] [Indexed: 12/13/2022]
Abstract
The main aim of the study was to identify and describe methods using non-ionizing radiation (NIR) such as electromagnetic fields (EMF) and optical radiation in Swedish health care. By examining anticipated exposure levels and by identifying possible health hazards we also aimed to recognize knowledge gaps in the field. NIR is mainly used in health care for diagnosis and therapy. Three applications were identified where acute effects cannot be ruled out: magnetic resonance imaging (MRI), transcranial magnetic stimulation (TMS) and electrosurgery. When using optical radiation, such as class 3 and 4 lasers for therapy or surgical procedures and ultra-violet light for therapy, acute effects such as unintentional burns, photo reactions, erythema and effects on the eyes need to be avoided. There is a need for more knowledge regarding long-term effects of MRI as well as on the combination of different NIR exposures. Based on literature and after consulting staff we conclude that the health care professionals' knowledge about the risks and safety measures should be improved and that there is a need for clear, evidence-based information from reliable sources, and it should be obvious to the user which source to address.
Collapse
Affiliation(s)
- Kjell Hansson Mild
- Department of Radiation Sciences, Umeå University, S-90185 Umeå, Sweden.
| | - Ronnie Lundström
- Department of Radiation Sciences, Umeå University, S-90185 Umeå, Sweden.
| | - Jonna Wilén
- Department of Radiation Sciences, Umeå University, S-90185 Umeå, Sweden.
| |
Collapse
|
13
|
Hartwig V, Virgili G, Ferrante Vero LF, De Marchi D, Landini L, Giovannetti G. TOWARDS A PERSONALISED AND INTERACTIVE ASSESSMENT OF OCCUPATIONAL EXPOSURE TO MAGNETIC FIELD DURING DAILY ROUTINE IN MAGNETIC RESONANCE. RADIATION PROTECTION DOSIMETRY 2018; 182:546-554. [PMID: 30053260 DOI: 10.1093/rpd/ncy114] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Accepted: 06/27/2018] [Indexed: 06/08/2023]
Abstract
Magnetic resonance imaging (MRI) is one of the most common sources of electromagnetic (EM) fields as a diagnostic technique widely used in medicine. MRI staff during the working day is constantly exposed to static and spatially heterogeneous magnetic field. Also, moving around the MRI room to perform their functions, workers are exposed to slowly time-varying magnetic fields that induce electrical currents and fields in the body. The development of new exposure assessment methodologies to collect exposure data at a personal level using simple everyday equipment is hence necessary, also in view of future epidemiological studies. This paper describes the design and testing of a novel device for assessing personal exposure to static and time-varying magnetic fields during daily clinical practice. The dosemeter will be also used to ensure effective training of technicians who will be instructed to avoid, where possible, risk behaviour in terms of high exposure.
Collapse
Affiliation(s)
- Valentina Hartwig
- Institute of Clinical Physiology, CNR, Via Moruzzi 1, Pisa, Italy
- Fondazione CNR-Regione Toscana 'G. Monasterio', Via Moruzzi 1, Pisa, Italy
| | | | | | - Daniele De Marchi
- Fondazione CNR-Regione Toscana 'G. Monasterio', Via Moruzzi 1, Pisa, Italy
- Associazione Italiana Tecnici dell'Imaging in Risonanza Magnetica, AITIRM, via XX Settembre 76, Firenze, Italy
| | - Luigi Landini
- Fondazione CNR-Regione Toscana 'G. Monasterio', Via Moruzzi 1, Pisa, Italy
| | - Giulio Giovannetti
- Institute of Clinical Physiology, CNR, Via Moruzzi 1, Pisa, Italy
- Fondazione CNR-Regione Toscana 'G. Monasterio', Via Moruzzi 1, Pisa, Italy
| |
Collapse
|
14
|
Evaluation of the Effectiveness of Protective Patches on Acupoints to Preserve the Bioenergetic Status against Magnetic Fields. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE 2018; 2018:4732130. [PMID: 30305830 PMCID: PMC6166365 DOI: 10.1155/2018/4732130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Accepted: 09/02/2018] [Indexed: 12/02/2022]
Abstract
The potentially harmful nature of electromagnetic fields (EMF) and static magnetic fields (SMF) has become a major problem in recent years. All these elements could be combined to produce cellular responses. For example, the orientation of molecules of water or other complex molecules, growth and cell viability, cell morphology, and intracellular metabolic pathways have demonstrated binding to magnetic fields. The effect of EMF and SMF on humans is a topic of great importance, especially because modern technology has introduced artificial magnetic fields such as those generated by power lines, mobile communications, and medical imaging equipment. A relevant problem is certainly that of professional exposure. The aim of this study was the evaluation of the effectiveness of a commercially available device, Skudo® patches (Edil Natura S.r.l., Novara, Italy), in protecting magnetic resonance operators from the influence of magnetic fields such as those present in the workplace. Skudo® patches are designed to protect microareas of the body from external electromagnetic disturbances. In this study, 10 male Italian volunteers aged between 50 and 60 were enrolled in the hospital. All participants were subjected to measurements at 4 specific time points to evaluate the effectiveness of Skudo® to counteract both EMF and SMF magnetic fields by evaluating the level of bioenergetic reactivity. To perform the measurements, a variant of the Ryodoraku method has been used, based upon the assessment of electropermeability. In particular, 12 acupoints were measured, one for each of the main meridians. This study shows that both SMF and EMF cause an alteration of the body's water system. The application of Skudo® patches determines a regularization of bioenergetic levels related to the water system. The application of Skudo® on the EMF source has suppressed the imbalance effect of the water system found in the subject without any protection.
Collapse
|
15
|
Bongers S, Slottje P, Kromhout H. Development of hypertension after long-term exposure to static magnetic fields among workers from a magnetic resonance imaging device manufacturing facility. ENVIRONMENTAL RESEARCH 2018; 164:565-573. [PMID: 29621724 DOI: 10.1016/j.envres.2018.03.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2017] [Revised: 03/02/2018] [Accepted: 03/05/2018] [Indexed: 06/08/2023]
Abstract
OBJECTIVE To assess the association between long-term exposure to static magnetic fields (SMF) in a magnetic resonance imaging (MRI)-manufacturing environment and hypertension. METHODS In an occupational cohort of male workers (n = 538) of an MRI-manufacturing facility, the first and last available blood pressure measurements from the facility's medical surveillance scheme were associated with modeled cumulative exposure to SMF. Exposure modeling was based on linkage of individual job histories from the facility's personnel records with a facility specific historical job exposure matrix. Hypertension was defined as a systolic pressure of above 140 mm Hg and/or a diastolic blood pressure above 90 mm Hg. Logistic regression models were used to associate cumulative SMF exposure to hypertension while adjusting for age, body mass index and blood pressure at time of first blood pressure measurement. Stratified analysis by exposure duration was performed similarly. RESULTS High cumulative exposure to SMF (≥ 7.4 K Tesla minutes) was positively associated with development of hypertension (Odds Ratio [OR] 2.32, 95% confidence interval [CI] 1.27 - 4.25, P = 0.006). Stratified analysis showed a stronger association for those with high cumulative SMF exposure within a period up to 10 years (OR 3.96, 95% CI 1.62 - 9.69, P = 0.003), but no significant association was found for (high) cumulative exposure accumulated in a period of 10 or more years. Our findings suggest SMF exposure intensity to be more important than exposure duration for the risk of developing hypertension. CONCLUSIONS Our data revealed that exposure to high levels of MRI-related SMF during MRI-manufacturing might be associated with developing hypertension.
Collapse
Affiliation(s)
- Suzan Bongers
- Environmental Epidemiology Division, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands
| | - Pauline Slottje
- Environmental Epidemiology Division, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands; Currently at Department of General Practice and Elderly Care Medicine, VU University Medical Centre, Amsterdam, The Netherlands
| | - Hans Kromhout
- Environmental Epidemiology Division, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands.
| |
Collapse
|
16
|
Frankel J, Wilén J, Hansson Mild K. Assessing Exposures to Magnetic Resonance Imaging's Complex Mixture of Magnetic Fields for In Vivo, In Vitro, and Epidemiologic Studies of Health Effects for Staff and Patients. Front Public Health 2018; 6:66. [PMID: 29594090 PMCID: PMC5858533 DOI: 10.3389/fpubh.2018.00066] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2017] [Accepted: 02/19/2018] [Indexed: 12/15/2022] Open
Abstract
A complex mixture of electromagnetic fields is used in magnetic resonance imaging (MRI): static, low-frequency, and radio frequency magnetic fields. Commonly, the static magnetic field ranges from one to three Tesla. The low-frequency field can reach several millitesla and with a time derivative of the order of some Tesla per second. The radiofrequency (RF) field has a magnitude in the microtesla range giving rise to specific absorption rate values of a few Watts per kilogram. Very little attention has been paid to the case where there is a combined exposure to several different fields at the same time. Some studies have shown genotoxic effects in cells after exposure to an MRI scan while others have not demonstrated any effects. A typical MRI exam includes muliple imaging sequences of varying length and intensity, to produce different types of images. Each sequence is designed with a particular purpose in mind, so one sequence can, for example, be optimized for clearly showing fat water contrast, while another is optimized for high-resolution detail. It is of the utmost importance that future experimental studies give a thorough description of the exposure they are using, and not just a statement such as “An ordinary MRI sequence was used.” Even if the sequence is specified, it can differ substantially between manufacturers on, e.g., RF pulse height, width, and duty cycle. In the latest SCENIHR opinion, it is stated that there is very little information regarding the health effects of occupational exposure to MRI fields, and long-term prospective or retrospective cohort studies on workers are recommended as a high priority. They also state that MRI is increasingly used in pediatric diagnostic imaging, and a cohort study into the effects of MRI exposure on children is recommended as a high priority. For the exposure assessment in epidemiological studies, there is a clear difference between patients and staff and further work is needed on this. Studies that explore the possible differences between MRI scan sequences and compare them in terms of exposure level are warranted.
Collapse
Affiliation(s)
- Jennifer Frankel
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | - Jonna Wilén
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | - Kjell Hansson Mild
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| |
Collapse
|
17
|
Berlana T, Úbeda A. OCCUPATIONAL EXPOSURE OF NMR SPECTROMETRISTS TO STATIC AND RADIOFREQUENCY FIELDS. RADIATION PROTECTION DOSIMETRY 2017; 177:397-406. [PMID: 28472522 DOI: 10.1093/rpd/ncx058] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Accepted: 04/13/2017] [Indexed: 06/07/2023]
Abstract
Occupational exposure to static and radiofrequency fields emitted by nuclear magnetic resonance spectrometers was assessed through systematic field metering during operation of 19 devices in nine research centers. Whereas no measurable levels of radiofrequency radiation were registered outside the spectrometers, significant exposure to static field was detected, with maximum values recorded at the user's hand (B = 683.00 mT) and head-thorax (B = 135.70 mT) during spectrometer manipulation. All values were well below the exposure limits set by the European standard for workers protection against the effects of acute field exposure only. As for potential effects of chronic exposure, waiting for more complete knowledge, adoption of technical and operational strategies for exposure minimizing is advisable. In this respect, the data revealed that compared with standard magnetic shielding, ultrashield technology allows a 20-65-fold reduction of the field strength received by the operator.
Collapse
Affiliation(s)
- Tania Berlana
- Servicio Prevención, Ministerio de Energía, Turismo y Agenda Digital, 28047 Madrid, Spain
| | - Alejandro Úbeda
- Servicio BEM, Hospital Ramón y Cajal-IRYCIS, 28034 Madrid, Spain
| |
Collapse
|
18
|
Kromhout H, Slottje P, Huss A, van Nierop LE, Bongers S, Schaap K, de Vocht F. ICNIRP Statement on Diagnostic Devices Using Non-Ionizing Radiation: Existing Regulations and Potential Health Risks. HEALTH PHYSICS 2017; 113:149-150. [PMID: 28658061 DOI: 10.1097/hp.0000000000000686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
|
19
|
Huss A, Schaap K, Kromhout H. MRI-related magnetic field exposures and risk of commuting accidents - A cross-sectional survey among Dutch imaging technicians. ENVIRONMENTAL RESEARCH 2017; 156:613-618. [PMID: 28454013 DOI: 10.1016/j.envres.2017.04.022] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2017] [Revised: 04/13/2017] [Accepted: 04/18/2017] [Indexed: 06/07/2023]
Abstract
BACKGROUND Imaging technicians working with magnetic resonance imaging (MRI) may experience acute effects such as vertigo or dizziness when being exposed. A previous study also reported an increased risk of accidents in MRI exposed staff. OBJECTIVES We aimed at evaluating commuting accident risk in Dutch imaging technicians. METHODS Of invited imaging technicians, 490 (29%) filled in a questionnaire pertaining to (near) accidents when driving or riding a bike, health, lifestyle and work practices. We used logistic regression to evaluate the association between exposure to MRI-related electromagnetic fields and risk of commuting (near) accidents in the year prior to the survey, adjusted for a range of potential confounders. RESULTS Our cross-sectional study indicated an increased risk of (near) accidents if imaging technicians had worked with MRI in the year prior to the survey (odds ratio OR 2.13, 95%CI 1.23-3.69). Risks were higher in persons who worked with MRI more often (OR 2.32, 95%CI 1.25-4.31) compared to persons who worked sometimes with MRI (OR 1.91, 95%CI 0.98-3.72), and higher in those who had likely experienced higher peak exposures to static and time-varying magnetic fields (OR 2.18, 95%CI 1.06-4.48). The effect was seen on commuting accidents that had occurred on the commute from home to work as well as accidents from work to home or elsewhere. CONCLUSION Imaging technicians working with MRI scanners may be at an increased risk of commuting (near) accidents. This result needs confirmation and potential risks for other groups (volunteers, patients) should be investigated.
Collapse
Affiliation(s)
- Anke Huss
- Institute for Risk Assessment Sciences, Utrecht University, The Netherlands.
| | - Kristel Schaap
- Institute for Risk Assessment Sciences, Utrecht University, The Netherlands; Leiden University Medical Centre, Leiden University, The Netherlands
| | - Hans Kromhout
- Institute for Risk Assessment Sciences, Utrecht University, The Netherlands
| |
Collapse
|
20
|
Huss A, Schaap K, Kromhout H. A survey on abnormal uterine bleeding among radiographers with frequent MRI exposure using intrauterine contraceptive devices. Magn Reson Med 2017; 79:1083-1089. [DOI: 10.1002/mrm.26707] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Revised: 02/27/2017] [Accepted: 03/18/2017] [Indexed: 11/09/2022]
Affiliation(s)
- A. Huss
- Institute for Risk Assessment Sciences; Utrecht University; the Netherlands
| | - K. Schaap
- Institute for Risk Assessment Sciences; Utrecht University; the Netherlands
| | - H. Kromhout
- Institute for Risk Assessment Sciences; Utrecht University; the Netherlands
| |
Collapse
|
21
|
Fatahi M, Karpowicz J, Gryz K, Fattahi A, Rose G, Speck O. Evaluation of exposure to (ultra) high static magnetic fields during activities around human MRI scanners. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2016; 30:255-264. [PMID: 27981395 DOI: 10.1007/s10334-016-0602-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2016] [Revised: 11/24/2016] [Accepted: 11/25/2016] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To assess the individual exposure to the static magnetic field (SMF) and the motion-induced time-varying magnetic field (TVMF) generated by activities in an inhomogeneous SMF near high and ultra-high field magnetic resonance imaging (MRI) scanners. The study provides information on the level of exposure to high and ultra-high field MRI scanners during research activities. MATERIALS AND METHODS A three-axis Hall magnetometer was used to determine the SMF and TVMF around human 3- and 7-Tesla (T) MRI systems. The 7-T MRI scanner used in this study was passively shielded and the 3-T scanner was actively shielded and both were from the same manufacturer. The results were compared with the exposure restrictions given by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). RESULTS The recorded exposure was highly variable between individuals, although they followed the same instructions for moving near the scanners. Maximum exposure values of B = 2057 mT and dB/dt = 4347 mT/s for the 3-T scanner and B = 2890 mT, dB/dt = 3900 mT/s for 7 T were recorded. No correlation was found between reporting the MRI-related sensory effects and exceeding the reference values. CONCLUSIONS According to the results of our single-center study with five subjects, violation of the ICNIRP restrictions for max B in MRI research environments was quite unlikely at 3 and 7 T. Occasions of exceeding the dB/dt limit at 3 and 7 T were almost similar (30% of 60 exposure scenarios) and highly variable among the individuals.
Collapse
Affiliation(s)
- Mahsa Fatahi
- Department of Biomedical Magnetic Resonance, H65-ZENIT, Otto-von-Guericke-University Magdeburg, Leipziger Street 44, 39120, Magdeburg, Germany.
| | - Jolanta Karpowicz
- Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection-National Res. Inst. (CIOP-PIB), Warsaw, Poland
| | - Krzysztof Gryz
- Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection-National Res. Inst. (CIOP-PIB), Warsaw, Poland
| | | | - Georg Rose
- Institute for Medical Engineering, Otto-von-Guericke University, Magdeburg, Germany
| | - Oliver Speck
- Department of Biomedical Magnetic Resonance, H65-ZENIT, Otto-von-Guericke-University Magdeburg, Leipziger Street 44, 39120, Magdeburg, Germany.,Leibniz Institute for Neurobiology, Magdeburg, Germany.,Center for Behavioral Brain Sciences, Magdeburg, Germany.,German Center for Neurodegenerative Disease, Site Magdeburg, Magdeburg, Germany
| |
Collapse
|
22
|
Iachininoto MG, Camisa V, Leone L, Pinto R, Lopresto V, Merla C, Giorda E, Carsetti R, Zaffina S, Podda MV, Teofili L, Grassi C. Effects of exposure to gradient magnetic fields emitted by nuclear magnetic resonance devices on clonogenic potential and proliferation of human hematopoietic stem cells. Bioelectromagnetics 2016; 37:201-11. [PMID: 26992028 DOI: 10.1002/bem.21967] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2015] [Accepted: 02/26/2016] [Indexed: 01/29/2023]
Abstract
This study investigates effects of gradient magnetic fields (GMFs) emitted by magnetic resonance imaging (MRI) devices on hematopoietic stem cells. Field measurements were performed to assess exposure to GMFs of staff working at 1.5 T and 3 T MRI units. Then an exposure system reproducing measured signals was realized to expose in vitro CD34+ cells to GMFs (1.5 T-protocol and 3 T-protocol). CD34+ cells were obtained by Fluorescence Activated Cell Sorting from six blood donors and three MRI-exposed workers. Blood donor CD34+ cells were exposed in vitro for 72 h to 1.5 T or 3 T-protocol and to sham procedure. Cells were then cultured and evaluated in colony forming unit (CFU)-assay up to 4 weeks after exposure. Results showed that in vitro GMF exposure did not affect cell proliferation but instead induced expansion of erythroid and monocytes progenitors soon after exposure and for the subsequent 3 weeks. No decrease of other clonogenic cell output (i.e., CFU-granulocyte/erythroid/macrophage/megakaryocyte and CFU-granulocyte/macrophage) was noticed, nor exposed CD34+ cells underwent the premature exhaustion of their clonogenic potential compared to sham-exposed controls. On the other hand, pilot experiments showed that CD34+ cells exposed in vivo to GMFs (i.e., samples from MRI workers) behaved in culture similarly to sham-exposed CD34+ cells, suggesting that other cells and/or microenvironment factors might prevent GMF effects on hematopoietic stem cells in vivo. Accordingly, GMFs did not affect the clonogenic potential of umbilical cord blood CD34+ cells exposed in vitro together with the whole mononuclear cell fraction.
Collapse
Affiliation(s)
| | - Vincenzo Camisa
- Occupational Medicine/Health Technology Assessment and Safety Research Unit, Clinical-Technological Innovations Research Area-Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Lucia Leone
- Institute of Human Physiology, Università Cattolica, Rome, Italy
| | - Rosanna Pinto
- ENEA, Italian Agency for New Technologies, Energy, and Sustainable Economic Development, Division of Health Protection Technologies, Casaccia Research Centre, Rome, Italy
| | - Vanni Lopresto
- ENEA, Italian Agency for New Technologies, Energy, and Sustainable Economic Development, Division of Health Protection Technologies, Casaccia Research Centre, Rome, Italy
| | - Caterina Merla
- ENEA, Italian Agency for New Technologies, Energy, and Sustainable Economic Development, Division of Health Protection Technologies, Casaccia Research Centre, Rome, Italy
| | - Ezio Giorda
- Immunology Unit, Immunology and Pharmacotherapy Research Area-Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Rita Carsetti
- Immunology Unit, Immunology and Pharmacotherapy Research Area-Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | - Salvatore Zaffina
- Occupational Medicine/Health Technology Assessment and Safety Research Unit, Clinical-Technological Innovations Research Area-Bambino Gesù Children's Hospital IRCCS, Rome, Italy
| | | | - Luciana Teofili
- Department of Transfusion Medicine, Institute of Hematology, Università Cattolica, Rome, Italy
| | - Claudio Grassi
- Institute of Human Physiology, Università Cattolica, Rome, Italy.,San Raffaele Pisana Scientific Institute for Research, Hospitalization and Health Care, Rome, Italy
| |
Collapse
|
23
|
Rostamzadeh A, Mohammadi M, Ahmadi R, Nazari A, Ghaderi O, Anjomshoa M. Evaluation of mouse embryos produced in vitro after electromagnetic waves exposure; Morphometric study. Electron Physician 2016; 8:1701-10. [PMID: 26955439 PMCID: PMC4768917 DOI: 10.19082/1701] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2015] [Accepted: 12/04/2015] [Indexed: 11/25/2022] Open
Abstract
Introduction Today, the use of electromagnetic waves in medical diagnostic devices, such as magnetic resonance imaging (MRI), has increased, and many of its biological effects have been reported. The aim of the present study was to assess the biological effects of 1.5 Tesla (T) magnetic resonance imaging (MRI) on fertility and reproductive parameters. Methods Eighty adult male and female NMRI mice (NMRI: Naval Medical Research Institute) of age 6–8 weeks were studied and randomly divided into two study and control groups. After confirmation of pregnancy, the mice in the study group were exposed to the MRI (1.5 T) machine’s waves over the next three weeks, once a week for 36 minutes. One day and thirty-five days after the last radiation, the mice were killed in order to do the in vitro fertilization (IVF) by neck beads’ displacement and the impact on the evolution of embryos, and its quality was studied. Data were analyzed using SPSS version 20 and the significance level of less than 0.05 was considered. Results Embryo morphometry showed that the total diameter and the cytoplasm diameter of the study group embryos suffered significant reduction compared to the control group, 1 day after the last irradiation (p < 0.05), but the diameter of the perivitelline space of this group’s embryos had a significant increase (p < 0.05). The qualitative results during 35 days after irradiation showed that morphologically parameters of the embryos in the study group had no significant differences from the control group. Conclusion Exposure to MRI irradiation can transiently disturb the development of mouse embryos and fertility, but these effects are reversible 35 days after the last irradiation.
Collapse
Affiliation(s)
- Ayoob Rostamzadeh
- M.Sc. of Anatomy, Faculty Member, Department of Anatomical Sciences, Faculty of Medicine, Shahrekord University of Medical Sciences, Shahrekord, Iran
| | - Mohsen Mohammadi
- Ph.D. of Pharmaceutical Biotechnology, Assistant Professor, Department of Pharmaceutical Biotechnology, Faculty of Pharmacy, Lorestan University of Medical Sciences, Khorramabad, Iran
| | - Reza Ahmadi
- Ph.D. Candidate of Clinical Biochemistry, Department of Clinical Biochemistry, Faculty of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Afshin Nazari
- Ph.D. of Physiology, Assistant Professor, Department of Physiology, Faculty of Medicine, Lorestan University of Medical Sciences, Khorramabad, Iran
| | - Omar Ghaderi
- Ph.D. Candidate of Pharmaceutical Biotechnology, Department of Pharmaceutical Biotechnology, Tehran University of Medical Sciences, Tehran, Iran
| | - Maryam Anjomshoa
- Ph.D. of Anatomy, Assistant Professor, Department of Anatomical Sciences, Faculty of Medicine, Shahrekord University of Medical Sciences, Shahrekord, Iran
| |
Collapse
|
24
|
Batistatou E, Mölter A, Kromhout H, van Tongeren M, Crozier S, Schaap K, Gowland P, Keevil SF, de Vocht F. Personal exposure to static and time-varying magnetic fields during MRI procedures in clinical practice in the UK. Occup Environ Med 2015; 73:779-786. [PMID: 26675205 PMCID: PMC5116531 DOI: 10.1136/oemed-2015-103194] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2015] [Accepted: 10/28/2015] [Indexed: 11/07/2022]
Abstract
Background MRI has developed into one of the most important medical diagnostic imaging modalities, but it exposes staff to static magnetic fields (SMF) when present in the vicinity of the MR system, and to radiofrequency and switched gradient electromagnetic fields if they are present during image acquisition. We measured exposure to SMF and motion-induced time-varying magnetic fields (TVMF) in MRI staff in clinical practice in the UK to enable extensive assessment of personal exposure levels and variability, which enables comparison to other countries. Methods 8 MRI facilities across National Health Service sites in England, Wales and Scotland were included, and staff randomly selected during the days when measurements were performed were invited to wear a personal MRI-compatible dosimeter and keep a diary to record all procedures and tasks performed during the measured shift. Results 98 participants, primarily radiographers (71%) but also other healthcare staff, anaesthetists and other medical staff were included, resulting in 149 measurements. Average geometric mean peak SMF and TVMF exposures were 448 mT (range 20–2891) and 1083 mT/s (9–12 355 mT/s), and were highest for radiographers (GM=559 mT and GM=734 mT/s). Time-weighted exposures to SMF and TVMF (GM=16 mT (range 5–64) and GM=14 mT/s (range 9–105)) and exposed-time-weighted exposures to SMF and TVMF (GM=27 mT (range 11–89) and GM=17 mT/s (range 9–124)) were overall relative low—primarily because staff were not in the MRI suite for most of their shifts—and did not differ significantly between occupations. Conclusions These results are comparable to the few data available from the UK but they differ from recent data collected in the Netherlands, indicating that UK staff are exposed for shorter periods but to higher levels. These data indicate that exposure to SMF and TVMF from MRI scanners cannot be extrapolated across countries.
Collapse
Affiliation(s)
- Evridiki Batistatou
- Centre for Occupational and Environmental Health, University of Manchester, Manchester, UK
| | - Anna Mölter
- Department of Environmental and Radiological Health Sciences, Colorado State University, Fort Collins, Colorado, USA
| | - Hans Kromhout
- Institute for Risk Assessment Sciences (IRAS), Utrecht University, Utrecht, The Netherlands
| | - Martie van Tongeren
- Centre for Human Exposure Science, Institute of Occupational Medicine, Edinburgh, UK
| | - Stuart Crozier
- School of Information Technology and Electrical Engineering, University of Queensland, Brisbane, Queensland, Australia
| | - Kristel Schaap
- Institute for Risk Assessment Sciences (IRAS), Utrecht University, Utrecht, The Netherlands
| | - Penny Gowland
- School of Physics and Astronomy, The University of Nottingham, Nottingham, UK
| | - Stephen F Keevil
- Department of Medical Physics, Guy's and St Thomas' NHS Foundation Trust, London, UK Department of Biomedical Engineering, King's College London, London, UK
| | - Frank de Vocht
- School of Social and Community Medicine, University of Bristol, Bristol, UK
| |
Collapse
|
25
|
Schaap K, Portengen L, Kromhout H. Exposure to MRI-related magnetic fields and vertigo in MRI workers. Occup Environ Med 2015; 73:161-6. [PMID: 26561507 DOI: 10.1136/oemed-2015-103019] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2015] [Accepted: 10/21/2015] [Indexed: 11/04/2022]
Abstract
OBJECTIVES Vertigo has been reported by people working around magnetic resonance imaging (MRI) scanners and was found to increase with increasing strength of scanner magnets. This suggests an association with exposure to static magnetic fields (SMF) and/or motion-induced time-varying magnetic fields (TVMF). This study assessed the association between various metrics of shift-long exposure to SMF and TVMF and self-reported vertigo among MRI workers. METHODS We analysed 358 shifts from 234 employees at 14 MRI facilities in the Netherlands. Participants used logbooks to report vertigo experienced during the work day at the MRI facility. In addition, personal exposure to SMF and TVMF was measured during the same shifts, using portable magnetic field dosimeters. RESULTS Vertigo was reported during 22 shifts by 20 participants and was significantly associated with peak and time-weighted average (TWA) metrics of SMF as well as TVMF exposure. Associations were most evident with full-shift TWA TVMF exposure. The probability of vertigo occurrence during a work shift exceeded 5% at peak exposure levels of 409 mT and 477 mT/s and at full-shift TWA levels of 3 mT and 0.6 mT/s. CONCLUSIONS These results confirm the hypothesis that vertigo is associated with exposure to MRI-related SMF and TVMF. Strong correlations between various metrics of shift-long exposure make it difficult to disentangle the effects of SMF and TVMF exposure, or identify the most relevant exposure metric. On the other hand, this also implies that several metrics of shift-long exposure to SMF and TVMF should perform similarly in epidemiological studies on MRI-related vertigo.
Collapse
Affiliation(s)
- Kristel Schaap
- Division of Environmental Epidemiology, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands
| | - Lützen Portengen
- Division of Environmental Epidemiology, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands
| | - Hans Kromhout
- Division of Environmental Epidemiology, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
26
|
Gourzoulidis G, Karabetsos E, Skamnakis Ν, Xrtistodoulou A, Kappas C, Theodorou K, Tsougos I, Maris T. Occupational Electromagnetic Fields exposure in Magnetic Resonance Imaging systems – Preliminary results for the RF harmonic content. Phys Med 2015; 31:757-62. [DOI: 10.1016/j.ejmp.2015.03.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2014] [Revised: 02/26/2015] [Accepted: 03/12/2015] [Indexed: 10/23/2022] Open
|
27
|
Zanotti G, Ligabue G, Gobba F. Subjective symptoms and their evolution in a small group of magnetic resonance imaging (MRI) operators recently engaged. Electromagn Biol Med 2015; 34:262-4. [DOI: 10.3109/15368378.2015.1076442] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
28
|
In Reply. Anesthesiology 2015; 123:977-8. [DOI: 10.1097/aln.0000000000000827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
29
|
|
30
|
Schaap K, Christopher-De Vries Y, Cambron-Goulet É, Kromhout H. Work-related factors associated with occupational exposure to static magnetic stray fields from MRI scanners. Magn Reson Med 2015; 75:2141-55. [DOI: 10.1002/mrm.25720] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2014] [Revised: 03/13/2015] [Accepted: 03/14/2015] [Indexed: 11/09/2022]
Affiliation(s)
- Kristel Schaap
- Institute for Risk Assessment Sciences, Division of Environmental Epidemiology, Utrecht University; Utrecht the Netherlands
| | - Yvette Christopher-De Vries
- Institute for Risk Assessment Sciences, Division of Environmental Epidemiology, Utrecht University; Utrecht the Netherlands
| | - Évelyne Cambron-Goulet
- Département des sciences de la santé communautaire; Université de Sherbrooke; Sherbrooke Canada
| | - Hans Kromhout
- Institute for Risk Assessment Sciences, Division of Environmental Epidemiology, Utrecht University; Utrecht the Netherlands
| |
Collapse
|
31
|
Bongers S, Slottje P, Portengen L, Kromhout H. Exposure to static magnetic fields and risk of accidents among a cohort of workers from a medical imaging device manufacturing facility. Magn Reson Med 2015; 75:2165-74. [DOI: 10.1002/mrm.25768] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2014] [Revised: 04/16/2015] [Accepted: 04/16/2015] [Indexed: 11/08/2022]
Affiliation(s)
- Suzan Bongers
- Environmental Epidemiology Division; Institute for Risk Assessment Sciences; Utrecht University; Utrecht the Netherlands
| | - Pauline Slottje
- Environmental Epidemiology Division; Institute for Risk Assessment Sciences; Utrecht University; Utrecht the Netherlands
| | - Lützen Portengen
- Environmental Epidemiology Division; Institute for Risk Assessment Sciences; Utrecht University; Utrecht the Netherlands
| | - Hans Kromhout
- Environmental Epidemiology Division; Institute for Risk Assessment Sciences; Utrecht University; Utrecht the Netherlands
| |
Collapse
|
32
|
Gorlin A, Hoxworth JM, Pavlicek W, Thunberg CA, Seamans D. Acute vertigo in an anesthesia provider during exposure to a 3T MRI scanner. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2015; 8:161-6. [PMID: 25792858 PMCID: PMC4362897 DOI: 10.2147/mder.s76474] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Vertigo induced by exposure to the magnetic field of a magnetic resonance imaging (MRI) scanner is a well-known phenomenon within the radiology community but is not widely appreciated by other clinical specialists. Here, we describe a case of an anesthetist experiencing acute vertigo while providing sedation to a patient undergoing a 3 Tesla MRI scan. After discussing previous reports, and the evidence surrounding MRI-induced vertigo, we review potential etiologies that include the effects of both static and time-varying magnetic fields on the vestibular apparatus. We conclude our review by discussing the occupational standards that exist for MRI exposure and methods to minimize the risks of MRI-induced vertigo for clinicians working in the MRI environment.
Collapse
Affiliation(s)
- Andrew Gorlin
- Department of Anesthesiology, Mayo Clinic Arizona, Phoenix, AZ, USA
| | | | | | | | - David Seamans
- Department of Anesthesiology, Mayo Clinic Arizona, Phoenix, AZ, USA
| |
Collapse
|
33
|
de Vocht F, Batistatou E, Mölter A, Kromhout H, Schaap K, van Tongeren M, Crozier S, Gowland P, Keevil S. Transient health symptoms of MRI staff working with 1.5 and 3.0 Tesla scanners in the UK. Eur Radiol 2015; 25:2718-26. [DOI: 10.1007/s00330-015-3629-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Revised: 12/12/2014] [Accepted: 01/21/2015] [Indexed: 11/28/2022]
|
34
|
Schaap K, Christopher-De Vries Y, Crozier S, De Vocht F, Kromhout H. Exposure to static and time-varying magnetic fields from working in the static magnetic stray fields of MRI scanners: a comprehensive survey in the Netherlands. ACTA ACUST UNITED AC 2014; 58:1094-110. [PMID: 25139484 DOI: 10.1093/annhyg/meu057] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Clinical and research staff who work around magnetic resonance imaging (MRI) scanners are exposed to the static magnetic stray fields of these scanners. Although the past decade has seen strong developments in the assessment of occupational exposure to electromagnetic fields from MRI scanners, there is insufficient insight into the exposure variability that characterizes routine MRI work practice. However, this is an essential component of risk assessment and epidemiological studies. This paper describes the results of a measurement survey of shift-based personal exposure to static magnetic fields (SMF) (B) and motion-induced time-varying magnetic fields (dB/dt) among workers at 15 MRI facilities in the Netherlands. With the use of portable magnetic field dosimeters, >400 full-shift and partial shift exposure measurements were collected among various jobs involved in clinical and research MRI. Various full-shift exposure metrics for B and motion-induced dB/dt exposure were calculated from the measurements, including instantaneous peak exposure and time-weighted average (TWA) exposures. We found strong correlations between levels of static (B) and time-varying (dB/dt) exposure (r = 0.88-0.92) and between different metrics (i.e. peak exposure, TWA exposure) to express full-shift exposure (r = 0.69-0.78). On average, participants were exposed to MRI-related SMFs during only 3.7% of their work shift. Average and peak B and dB/dt exposure levels during the work inside the MRI scanner room were highest among technical staff, research staff, and radiographers. Average and peak B exposure levels were lowest among cleaners, while dB/dt levels were lowest among anaesthesiology staff. Although modest exposure variability between workplaces and occupations was observed, variation between individuals of the same occupation was substantial, especially among research staff. This relatively large variability between workers with the same job suggests that exposure classification based solely on job title may not be an optimal grouping strategy for epidemiological purposes.
Collapse
Affiliation(s)
- Kristel Schaap
- Institute for Risk Assessment Sciences, Division of Environmental Epidemiology, Utrecht University, Utrecht 3508 TD, Netherlands;
| | - Yvette Christopher-De Vries
- Institute for Risk Assessment Sciences, Division of Environmental Epidemiology, Utrecht University, Utrecht 3508 TD, Netherlands
| | - Stuart Crozier
- The School of Information Technology and Electrical Engineering, University of Queensland, St Lucia, Brisbane, QLD 4072, Australia
| | - Frank De Vocht
- School of Social and Community Medicine, University of Bristol, Bristol BS8 2PS, UK
| | - Hans Kromhout
- Institute for Risk Assessment Sciences, Division of Environmental Epidemiology, Utrecht University, Utrecht 3508 TD, Netherlands;
| |
Collapse
|
35
|
Karpowicz J, Gryz K. The pattern of exposure to static magnetic field of nurses involved in activities related to contrast administration into patients diagnosed in 1.5 T MRI scanners. Electromagn Biol Med 2014; 32:182-91. [PMID: 23675621 DOI: 10.3109/15368378.2013.776428] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Static magnetic fields (SMFs) and time-varying electromagnetic fields exposure is necessary to obtain the diagnostic information regarding the structure of patient's tissues, by the use of magnetic resonance imaging (MRI) scanners. A diagnostic procedure may also include the administration of pharmaceuticals called contrast, which are to be applied to a patient during the examination. The nurses involved in administering contrast into a patient during the pause in examination are approaching permanently active magnets of MRI scanners and are exposed to SMF. There were performed measurements of spatial distribution of SMF in the vicinity of MRI magnets and parameters of personal exposure of nurses (i.e. individual exposimetric profiles of variability in time of SMF affecting the nurse who is performing tasks in the vicinity of magnet, characterized by statistical parameters of recorded magnetic flux density affecting the nurse). The SMF exposure in the vicinity of various MRI magnets depends on both magnetic flux density of the main field B 0 (applicable to a patient) and the construction of the scanner, but the most important factor determining the workers' exposure is the work practice. In the course of a patient's routine examination in scanners of B₀ = 1.5 T, the nurses are present over ∼0.4-2.9 min in SMF exceeding 0.03% of B₀ (i.e. 0.5 mT), but only sometimes they are present in SMF exceeding 5% of B 0 (i.e. 75 mT). When patients need more attention because of their health status/condition, the nurses' exposure may be significantly longer--it may even exceed 10 min and 30% of B 0 (i.e. 500 mT). We have found that the level of exposure of nurses to SMF may vary from < 5% of the main field (a median value: 0.5-1.5%; inter-quartile range: 0.04-8.8%; max value: 1.3-12% of B₀) when a patient is moved from the magnets bore before contrast administration, up to the main field level (B₀) when a patient stays in the magnets bore and nurse is crawling into the bore.
Collapse
Affiliation(s)
- Jolanta Karpowicz
- Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection-National Research Institute-CIOP-PIB, Warszawa, Poland.
| | | |
Collapse
|
36
|
Schaap K, Christopher-de Vries Y, Mason CK, de Vocht F, Portengen L, Kromhout H. Occupational exposure of healthcare and research staff to static magnetic stray fields from 1.5-7 Tesla MRI scanners is associated with reporting of transient symptoms. Occup Environ Med 2014; 71:423-9. [PMID: 24714654 PMCID: PMC4033112 DOI: 10.1136/oemed-2013-101890] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Objectives Limited data is available about incidence of acute transient symptoms associated with occupational exposure to static magnetic stray fields from MRI scanners. We aimed to assess the incidence of these symptoms among healthcare and research staff working with MRI scanners, and their association with static magnetic field exposure. Methods We performed an observational study among 361 employees of 14 clinical and research MRI facilities in The Netherlands. Each participant completed a diary during one or more work shifts inside and/or outside the MRI facility, reporting work activities and symptoms (from a list of potentially MRI-related symptoms, complemented with unrelated symptoms) experienced during a working day. We analysed 633 diaries. Exposure categories were defined by strength and type of MRI scanner, using non-MRI shifts as the reference category for statistical analysis. Non-MRI shifts originated from MRI staff who also participated on MRI days, as well as CT radiographers who never worked with MRI. Results Varying per exposure category, symptoms were reported during 16–39% of the MRI work shifts. We observed a positive association between scanner strength and reported symptoms among healthcare and research staff working with closed-bore MRI scanners of 1.5 Tesla (T) and higher (1.5 T OR=1.88; 3.0 T OR=2.14; 7.0 T OR=4.17). This finding was mainly driven by reporting of vertigo and metallic taste. Conclusions The results suggest an exposure-response association between exposure to strong static magnetic fields (and associated motion-induced time-varying magnetic fields) and reporting of transient symptoms on the same day of exposure. Trial registration number 11-032/C
Collapse
Affiliation(s)
- Kristel Schaap
- Division of Environmental Epidemiology, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands
| | | | | | | | | | | |
Collapse
|
37
|
Yamaguchi-Sekino S, Nakai T, Imai S, Izawa S, Okuno T. Occupational exposure levels of static magnetic field during routine MRI examination in 3T MR system. Bioelectromagnetics 2013; 35:70-5. [PMID: 24115150 DOI: 10.1002/bem.21817] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2012] [Accepted: 08/28/2013] [Indexed: 11/08/2022]
Abstract
Occupational exposure to the high static magnetic fields (SMFs) during magnetic resonance imaging (MRI) examinations raises concerns of adverse health effects. In this study, personal exposure monitoring of the magnetic fields during routine examinations in two 3 T MRI systems was carried out. A three-axis Hall magnetometer was attached to a subject's chest during monitoring. Data acquisition started every time the subject entered the scanner room and ended when the subject exited the room. Four radiologic technologists from two different institutes participated in this study. The maximum exposed field ranged from 0 to 1250 mT and the average peak magnetic field (B) was 428 ± 231 mT (mean ± standard deviation (SD): number of samples (N) = 103). Then, the relationship between exposure levels and work duties was analyzed. The MRI examination of the head or neck showed the highest average peak B among four work categories. These results provide information of real exposure levels for 3 T MRI system operators and can also improve the current practical training advice for preventing extra occupational field exposure.
Collapse
|
38
|
Bongers S, Christopher Y, Engels H, Slottje P, Kromhout H. Retrospective assessment of exposure to static magnetic fields during production and development of magnetic resonance imaging systems. ACTA ACUST UNITED AC 2013; 58:85-102. [PMID: 24081380 DOI: 10.1093/annhyg/met049] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
At present, the relationship between chronic exposure to static magnetic fields (SMF) and health effects is unclear. We developed a task-based deterministic model for estimating historical electromagnetic field exposure from the static B-field (B0) of magnetic resonance imaging (MRI) systems, for a cohort of employees working at an MRI systems development and production facility. Technical maps describing the spatial distribution of fringe fields of B0 surrounding different types of MRI systems of various core strengths were exploited to derive estimates of static B0 exposure as a function of distance from the bore of the MRI system. Detailed information on tasks performed per exposed job and other model determinants were acquired through face-to-face interviews and used to derive base estimates of most recent exposure (2009) for each job title. The model was partially validated with actual exposure measurements. The exposure estimates from the deterministic model were used to construct a job-exposure matrix that will enable estimation of cumulative exposures for each cohort member. The generic approach described for estimating chronic MRI-related SMF exposure makes it universally applicable in other studies investigating health effects of MRI-related SMF exposure.
Collapse
Affiliation(s)
- Suzan Bongers
- Environmental Epidemiology Division, Institute for Risk Assessment Sciences, Utrecht University, PO Box 80.178, Utrecht 3508 TD, the Netherlands
| | | | | | | | | |
Collapse
|
39
|
Schaap K, Christopher-De Vries Y, Slottje P, Kromhout H. Inventory of MRI applications and workers exposed to MRI-related electromagnetic fields in the Netherlands. Eur J Radiol 2013; 82:2279-85. [PMID: 24055183 DOI: 10.1016/j.ejrad.2013.07.023] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2013] [Revised: 06/04/2013] [Accepted: 07/26/2013] [Indexed: 10/26/2022]
Abstract
OBJECTIVE This study aims to characterise and quantify the population that is occupationally exposed to electromagnetic fields (EMF) from magnetic resonance imaging (MRI) devices and to identify factors that determine the probability and type of exposure. MATERIALS AND METHODS A questionnaire survey was used to collect information about scanners, procedures, historical developments and employees working with or near MRI scanners in clinical and research MRI departments in the Netherlands. RESULTS Data were obtained from 145 MRI departments. A rapid increase in the use of MRI and field strength of the scanners was observed and quantified. The strongest magnets were employed by academic hospitals and research departments. Approximately 7000 individuals were reported to be working inside an MRI scanner room and were thus considered to have high probability of occupational exposure to static magnetic fields (SMF). Fifty-four per cent was exposed to SMF at least one day per month. The largest occupationally exposed group were radiographers (n ~ 1700). Nine per cent of the 7000 involved workers were regularly present inside a scanner room during image acquisition, when exposure to additional types of EMF is considered a possibility. This practice was most prevalent among workers involved in scanning animals. CONCLUSION The data illustrate recent trends and historical developments in magnetic resonance imaging and provide an extensive characterisation of the occupationally exposed population. A considerable number of workers are potentially exposed to MRI-related EMF. Type and frequency of potential exposure depend on the job performed, as well as the type of workplace.
Collapse
Affiliation(s)
- Kristel Schaap
- Division of Environmental Epidemiology, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands
| | | | | | | |
Collapse
|
40
|
van Nierop LE, Slottje P, Kingma H, Kromhout H. MRI-related static magnetic stray fields and postural body sway: a double-blind randomized crossover study. Magn Reson Med 2012; 70:232-40. [PMID: 22886724 DOI: 10.1002/mrm.24454] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2012] [Revised: 07/03/2012] [Accepted: 07/11/2012] [Indexed: 01/08/2023]
Abstract
We assessed postural body sway performance after exposure to movement induced time-varying magnetic fields in the static magnetic stray field in front of a 7 Tesla (T) magnetic resonance imaging scanner. Using a double blind randomized crossover design, 30 healthy volunteers performed two balance tasks (i.e., standing with eyes closed and feet in parallel and then in tandem position) after standardized head movements in a sham, low exposure (on average 0.24 T static magnetic stray field and 0.49 T·s(-1) time-varying magnetic field) and high exposure condition (0.37 T and 0.70 T·s(-1)). Personal exposure to static magnetic stray fields and time-varying magnetic fields was measured with a personal dosimeter. Postural body sway was expressed in sway path, area, and velocity. Mixed-effects model regression analysis showed that postural body sway in the parallel task was negatively affected (P < 0.05) by exposure on all three measures. The tandem task revealed the same trend, but did not reach statistical significance. Further studies are needed to investigate the possibility of independent or synergetic effects of static magnetic stray field and time-varying magnetic field exposure. In addition, practical safety implications of these findings, e.g., for surgeons and others working near magnetic resonance imaging scanners need to be investigated.
Collapse
Affiliation(s)
- Lotte E van Nierop
- Division of Environmental Epidemiology, Institute for Risk Assessment Sciences, Utrecht University, The Netherlands.
| | | | | | | |
Collapse
|
41
|
Hansson Mild K, Hand J, Hietanen M, Gowland P, Karpowicz J, Keevil S, Lagroye I, van Rongen E, Scarfi MR, Wilén J. Exposure classification of MRI workers in epidemiological studies. Bioelectromagnetics 2012; 34:81-4. [PMID: 22532229 DOI: 10.1002/bem.21728] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2011] [Accepted: 03/23/2012] [Indexed: 11/06/2022]
Abstract
We estimate that there are about 100,000 workers from different disciplines, such as radiographers, nurses, anesthetists, technicians, engineers, etc., who can be exposed to substantial electromagnetic fields (compared to normal background levels) around magnetic resonance imaging (MRI) scanners. There is a need for well-designed epidemiological studies of MRI workers but since the exposure from MRI equipment is a very complex mixture of static magnetic fields, switched gradient magnetic fields, and radiofrequency electromagnetic fields (RF EMF), it is necessary to discuss how to assess the exposure in epidemiological studies. As an alternative to the use of job title as a proxy of exposure, we propose an exposure categorization for the different professions working with MRI equipment. Specifically, we propose defining exposure in three categories, depending on whether people are exposed to only the static field, to the static plus switched gradient fields or to the static plus switched gradient plus RF fields, as a basis for exposure assessment in epidemiological studies.
Collapse
|
42
|
Health Effects and Safety of Magnetic Resonance Imaging. J Med Syst 2011; 36:1779-80. [DOI: 10.1007/s10916-010-9637-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2010] [Accepted: 12/06/2010] [Indexed: 10/18/2022]
|