1
|
Silva-Neto HA, Barbeira PJS, Coltro WKT, Piccin E. 3D printing of electrochemical cell for voltammetric detection and photodegradation monitoring of folic acid in juice samples. Food Chem 2024; 444:138677. [PMID: 38359702 DOI: 10.1016/j.foodchem.2024.138677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 01/11/2024] [Accepted: 02/02/2024] [Indexed: 02/17/2024]
Abstract
In this study, compact 3D-printed carbon black (CB) electrodes were manufactured for using in folic acid (FA) analysis in fruit samples. Before application in FA analysis, the electrode surfaces were characterized by high-resolution scanning electron microscopy and voltammetry using well-known redox probes. Square wave voltammetric study presented linear responses in the range between 10 and 200 µmol/L (R2 > 0.99), exhibited a suitable detection limit (LOD) of ∼ 5.1 µmol/L and acceptable performance in terms of reproducibility and anti-interference experiments. The analysis of FA in four different food samples using the proposed method agreed statistically with a comparative technique based on spectrophotometric measurements. Moreover, results from photostability experiments indicated that FA can be degraded after 5 and 20 min of UV exposure. These results successfully demonstrated the analytical feasibility of the 3D-printed electrodes as sensing material and for monitoring the photostability of FA in different fruit matrices.
Collapse
Affiliation(s)
- Habdias A Silva-Neto
- Departamento de Química, Universidade Federal de Minas Gerais, MG 31270-400, Brazil; Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil.
| | - Paulo J S Barbeira
- Departamento de Química, Universidade Federal de Minas Gerais, MG 31270-400, Brazil
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, SP 13084-971, Brazil
| | - Evandro Piccin
- Departamento de Química, Universidade Federal de Minas Gerais, MG 31270-400, Brazil; Departamento do Química, Universidade Federal de São Carlos, SP 13565-905, Brazil.
| |
Collapse
|
2
|
Qian M, Zhang Y, Bian Y, Feng XS, Zhang ZB. Nitrophenols in the environment: An update on pretreatment and analysis techniques since 2017. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2024; 281:116611. [PMID: 38909393 DOI: 10.1016/j.ecoenv.2024.116611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 06/07/2024] [Accepted: 06/15/2024] [Indexed: 06/25/2024]
Abstract
Nitrophenols, a versatile intermediate, have been widely used in leather, medicine, chemical synthesis, and other fields. Because these components are widely applied, they can enter the environment through various routes, leading to many hazards and toxicities. There has been a recent surge in the development of simple, rapid, environmentally friendly, and effective techniques for determining these environmental pollutants. This review provides a comprehensive overview of the latest research progress on the pretreatment and analysis methods of nitrophenols since 2017, with a focus on environmental samples. Pretreatment methods include liquid-liquid extraction, solid-phase extraction, dispersive extraction, and microextraction methods. Analysis methods mainly include liquid chromatography-based methods, gas chromatography-based methods, supercritical fluid chromatography. In addition, this review also discusses and compares the advantages/disadvantages and development prospects of different pretreatment and analysis methods to provide a reference for further research.
Collapse
Affiliation(s)
- Min Qian
- School of Pharmacy, China Medical University, Shenyang 110122, China
| | - Yuan Zhang
- School of Pharmacy, China Medical University, Shenyang 110122, China
| | - Yu Bian
- School of Pharmacy, China Medical University, Shenyang 110122, China
| | - Xue-Song Feng
- School of Pharmacy, China Medical University, Shenyang 110122, China.
| | - Zhong-Bo Zhang
- Department of Pancreatic and Biliary Surgery, The First Hospital of China Medical University, Shenyang 110001, China.
| |
Collapse
|
3
|
Novel solid inks based on beeswax, graphite and graphene applied to the fabrication of paper-based sensor for galactose determination. Talanta 2023; 257:124372. [PMID: 36801559 DOI: 10.1016/j.talanta.2023.124372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 10/20/2022] [Accepted: 02/14/2023] [Indexed: 02/16/2023]
Abstract
In this study, we present for the first time a simple and novel method for the fabrication of paper-based electrochemical sensors. The device development was carried out in a single stage with a standard wax printer. Hydrophobic zones were delimited with commercial solid ink, while electrodes were generated using new composite solid inks of graphene oxide/graphite/beeswax (GO/GRA/beeswax) and graphite/beeswax (GRA/beeswax). Subsequently, the electrodes were electrochemically activated by applying an overpotential. Various experimental variables for the GO/GRA/beeswax composite synthesis and electrochemical system obtention were evaluated. The activation process was examined by SEM, FTIR, cyclic voltammetry, electrochemical impedance spectroscopy and contact angle measurement. These studies showed morphological and chemical changes in the electrode active surface. As a result, the activation stage considerably improved the electron transfer on the electrode. The manufactured device was successfully applied for galactose (Gal) determination. This method presented a linear relation in the Gal concentration range from 84 to 1736 μmol L-1, with a LOD of 0.1 μmol L-1. The variation within and between-assay coefficients were 5.3% and 6.8%, respectively. The strategy here exposed for paper-based electrochemical sensors design is an unprecedented alternative system and represents a promising tool for mass production of economic analytical devices.
Collapse
|
4
|
Chung S, Loh A, Jennings CM, Sosnowski K, Ha SY, Yim UH, Yoon JY. Capillary flow velocity profile analysis on paper-based microfluidic chips for screening oil types using machine learning. JOURNAL OF HAZARDOUS MATERIALS 2023; 447:130806. [PMID: 36680906 PMCID: PMC9940998 DOI: 10.1016/j.jhazmat.2023.130806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 12/29/2022] [Accepted: 01/15/2023] [Indexed: 06/17/2023]
Abstract
We conceived a novel approach to screen oil types on a wax-printed paper-based microfluidic platform. Various oil samples spontaneously flowed through a micrometer-scale channel via capillary action while their components were filtered and partitioned. The resulting capillary flow velocity profile fluctuated during the flow, which was used to screen oil types. Raspberry Pi camera captured the video clips, and a custom Python code analyzed them to obtain the capillary flow velocity profiles. 106 velocity profiles (each with 125 frames for 5 s) were recorded from various oil samples to build a training database. Principal component analysis (PCA), support vector machine (SVM), and linear discriminant analysis (LDA) were used to classify the oil types into heavy-to-medium crude, light crude, marine fuel, lubricant, and diesel oils. The second-order polynomial SVM model with PCA as a pre-processing step showed the highest accuracy: 90% in classifying crude oils and 81% in classifying non-crude oils. The assay took less than 30 s from the sample to answer, with 5 s of the capillary action-driven flow. This simple and effective assay will allow rapid preliminary screening of oil types, enable early tracking, and reduce the number of suspect samples to be analyzed by laboratory fingerprinting analysis.
Collapse
Affiliation(s)
- Soo Chung
- Department of Biosystems Engineering, The University of Arizona, Tucson, AZ 85721, United States; Department of Biosystems Engineering, Integrated Major in Global Smart Farm, and Research Institute of Agriculture and Life Sciences, Seoul National University, Seoul 08826, Republic of Korea
| | - Andrew Loh
- Korea Institute of Ocean Science and Technology, Geoje-si, Gyeongsangnam-do 53201, Republic of Korea
| | - Christian M Jennings
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, United States
| | - Katelyn Sosnowski
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, United States
| | - Sung Yong Ha
- Korea Institute of Ocean Science and Technology, Geoje-si, Gyeongsangnam-do 53201, Republic of Korea
| | - Un Hyuk Yim
- Korea Institute of Ocean Science and Technology, Geoje-si, Gyeongsangnam-do 53201, Republic of Korea.
| | - Jeong-Yeol Yoon
- Department of Biosystems Engineering, The University of Arizona, Tucson, AZ 85721, United States; Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, United States.
| |
Collapse
|
5
|
Kaur M, Yempally V, Kaur H. Sustainable magnetically recoverable Iridium-coated Fe 3O 4 nanoparticles for enhanced catalytic reduction of organic pollutants in water. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:56464-56483. [PMID: 36920618 DOI: 10.1007/s11356-023-26267-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 02/28/2023] [Indexed: 06/18/2023]
Abstract
The reduction of nitroarenes to aromatic amines is one of the potential pathways to remediate the hazardous impact of toxic nitroarenes on the aquatic environment. Aromatic amines obtained from the reduction of nitroaromatics are not only less toxic than nitroaromatics but also act as important intermediates in the synthesis of dyes, drugs, pigments, herbicides, and polymers. There is a huge demand for the development of cost-effective, and eco-friendly catalysts for the efficient reduction of nitroarenes. In the present study, Fe3O4@trp@Ir nanoparticles were explored as efficient catalysts for the reduction of nitroarenes. Fe3O4@trp@Ir magnetic nanoparticles were fabricated by surface coating of Fe3O4 with tryptophan and iridium by co-precipitation method. As-prepared Fe3O4@trp@Ir nanoparticles are environmentally benign efficient catalysts for reducing organic pollutants such as 4-nitrophenol (4-NP), 4-nitroaniline (4-NA), and 1-bromo-4-nitrobenzene (1-B-4-NB). The key parameters that affect the catalytic activity like temperature, catalyst loading, and the concentration of reducing agent NaBH4 were optimized. The obtained results proved that Fe3O4@trp@Ir is an efficient catalyst for reducing nitroaromatics at ambient temperature with a minimal catalyst loading of 0.0025%. The complete conversion of 4-nitrophenol to 4-aminophenol took only 20 s with a minimal catalyst loading of 0.0025% and a rate constant of 0.0522 s-1. The high catalytic activity factor (1.040 s-1 mg-1) and high turnover frequency (9 min-1) obtained for Fe3O4@trp@Ir nanocatalyst highlight the possible synergistic effect of the two metals (Fe and Ir). The visible-light photocatalytic degradation of 4-NP was also investigated in the presence of Fe3O4@trp@Ir. The photocatalytic degradation of 4-NP by Fe3O4@trp@Ir is completed in 20 min with 95.15% efficiency, and the rate of photodegradation of 4-NP (0.1507 min-1) is about twice the degradation rate of 4-NP in the dark (0.0755 min-1). The catalyst was recycled and reused for five cycles without significant reduction in the conversion efficiency of the catalyst.
Collapse
Affiliation(s)
- Manpreet Kaur
- Department of Applied Sciences, Punjab Engineering College (Deemed to Be University), Sector-12, Chandigarh, India
| | - Veeranna Yempally
- Department of Applied Sciences, Punjab Engineering College (Deemed to Be University), Sector-12, Chandigarh, India
| | - Harminder Kaur
- Department of Applied Sciences, Punjab Engineering College (Deemed to Be University), Sector-12, Chandigarh, India.
| |
Collapse
|
6
|
Kummari S, Panicker LR, Rao Bommi J, Karingula S, Sunil Kumar V, Mahato K, Goud KY. Trends in Paper-Based Sensing Devices for Clinical and Environmental Monitoring. BIOSENSORS 2023; 13:bios13040420. [PMID: 37185495 PMCID: PMC10135896 DOI: 10.3390/bios13040420] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 03/20/2023] [Accepted: 03/23/2023] [Indexed: 05/17/2023]
Abstract
Environmental toxic pollutants and pathogens that enter the ecosystem are major global issues. Detection of these toxic chemicals/pollutants and the diagnosis of a disease is a first step in efficiently controlling their contamination and spread, respectively. Various analytical techniques are available to detect and determine toxic chemicals/pathogens, including liquid chromatography, HPLC, mass spectroscopy, and enzyme-linked immunosorbent assays. However, these sensing strategies have some drawbacks such as tedious sample pretreatment and preparation, the requirement for skilled technicians, and dependence on large laboratory-based instruments. Alternatively, biosensors, especially paper-based sensors, could be used extensively and are a cost-effective alternative to conventional laboratory testing. They can improve accessibility to testing to identify chemicals and pollutants, especially in developing countries. Due to its low cost, abundance, easy disposal (by incineration, for example) and biocompatible nature, paper is considered a versatile material for the development of environmentally friendly electrochemical/optical (bio) sensor devices. This review presents an overview of sensing platforms constructed from paper, pointing out the main merits and demerits of paper-based sensing systems, their fabrication techniques, and the different optical/electrochemical detection techniques that they exploit.
Collapse
Affiliation(s)
- Shekher Kummari
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad 678557, Kerala, India
| | - Lakshmi R Panicker
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad 678557, Kerala, India
| | | | - Sampath Karingula
- Department of Chemistry, National Institute of Technology, Warangal 506004, Telangana, India
| | - Venisheety Sunil Kumar
- Department of Physical Sciences, Kakatiya Institute of Technology and Science, Warangal 506015, Telangana, India
| | - Kuldeep Mahato
- Department of Nanoengineering, University of California, La Jolla, San Diego, CA 92093, USA
| | - Kotagiri Yugender Goud
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad 678557, Kerala, India
| |
Collapse
|
7
|
Hasan MR, Sharma P, Shaikh S, Singh S, Pilloton R, Narang J. Electrochemical Aptasensor Developed Using Two-Electrode Setup and Three-Electrode Setup: Comprising Their Current Range in Context of Dengue Virus Determination. BIOSENSORS 2022; 13:bios13010001. [PMID: 36671836 PMCID: PMC9855785 DOI: 10.3390/bios13010001] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 11/29/2022] [Accepted: 11/30/2022] [Indexed: 05/31/2023]
Abstract
We present, for the very first time, the fabrication and electrochemical characterization of a paper-based experimental platform for dengue virus analysis. The paper-based device incorporates a screen-printing technology with the help of black carbon conductive ink. The paper-based device utilizes two styles of electrode setups, i.e., the two-electrode system and three-electrode system, and both setups effectively detected the dengue virus with an LOD of 0.1 µg/mL; however, these paper electrodes exhibit various current ranges, and the created sensor was encompassed and compared in this research based on current response. It is observed that the three-electrode system has a substantially higher current range, ranging from 55.53 µA to 322.21 µA, as compared to the two-electrode system, which has a current range of 0.85 µA to 4.54 µA. According to this study, the three-electrode system displayed a good range of current amplification that is roughly 50 times higher than the two-electrode system, which had a weak current response. As a result, the three-electrode method has emerged as a viable option for the very sensitive detection of the dengue virus, as well as for the diagnosis of other diseases.
Collapse
Affiliation(s)
- Mohd. Rahil Hasan
- Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, New Delhi 110062, India
| | - Pradakshina Sharma
- Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, New Delhi 110062, India
| | - Shifa Shaikh
- Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, New Delhi 110062, India
| | - Saumitra Singh
- Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, New Delhi 110062, India
| | - Roberto Pilloton
- Institute of Crystallography of National Research Council (IC-CNR), 00118 Rome, Italy
| | - Jagriti Narang
- Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard, New Delhi 110062, India
| |
Collapse
|
8
|
Anushka, Bandopadhyay A, Das PK. Paper based microfluidic devices: a review of fabrication techniques and applications. THE EUROPEAN PHYSICAL JOURNAL. SPECIAL TOPICS 2022; 232:781-815. [PMID: 36532608 PMCID: PMC9743133 DOI: 10.1140/epjs/s11734-022-00727-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 11/09/2022] [Indexed: 06/14/2023]
Abstract
A wide range of applications are possible with paper-based analytical devices, which are low priced, easy to fabricate and operate, and require no specialized equipment. Paper-based microfluidics offers the design of miniaturized POC devices to be applied in the health, environment, food, and energy sector employing the ASSURED (Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment free and Deliverable to end users) principle of WHO. Therefore, this field is growing very rapidly and ample research is being done. This review focuses on fabrication and detection techniques reported to date. Additionally, this review emphasises on the application of this technology in the area of medical diagnosis, energy generation, environmental monitoring, and food quality control. This review also presents the theoretical analysis of fluid flow in porous media for the efficient handling and control of fluids. The limitations of PAD have also been discussed with an emphasis to concern on the transformation of such devices from laboratory to the consumer.
Collapse
Affiliation(s)
- Anushka
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302 India
| | - Aditya Bandopadhyay
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302 India
| | - Prasanta Kumar Das
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302 India
| |
Collapse
|
9
|
Ferreira de Oliveira AE, César Pereira A, Ferreira LF. Fully handwritten electrodes on paper substrate using rollerball pen with silver nanoparticle ink, marker pen with carbon nanotube ink and graphite pencil. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:1880-1888. [PMID: 35506547 DOI: 10.1039/d2ay00373b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Herein, a so-called carbon nanotube (CNT) electrode was printed in on a paper substrate using the handwriting technique and carbon nanotube ink in a marker pen to print the working electrode, graphite pencil to print the counter electrode and graphite/silver nanoparticle (AgNP) ink in a rollerball pen to print the quasi-reference electrode. The carbon nanotube electrode was characterized via scanning electron microscopy. The electrode was optimized based on the type of paper, hydrophobic barrier and number of layers. In summary, the optimized parameters included the use of matte paper with a mineral spirit layer. The number of carbon nanotube layers to achieve the best electrochemical performance was 25. The final graphite electrode was a miniaturized and flexible paper-based electrochemical electrode. To evaluate the electrical properties of the electrodes, the ohmic resistance of each ink was tested using a multimeter and the obtained values were 18.62 kΩ for the CNT ink, 1.53 Ω for the AgNP ink and 3.53 kΩ for the graphite trace. These results indicate the good conductivity of each synthesized ink used in the fabrication of the CNT electrode. Finally, the electrode was used to measure the electrochemical response of different concentrations of K4[Fe(CN)6]. Then, a calibration curve was obtained from the voltammograms and linearity was observed in the range of 0.5-3.5 mM. This suggests that the CNT electrode has the potential to be used as an amperometric electrode.
Collapse
Affiliation(s)
- Ana Elisa Ferreira de Oliveira
- Departamento de Ciências Naturais, Universidade Federal de São João del-Rei, UFSJ, São João del-Rei, MG, CEP 36307-352, Brazil.
| | - Arnaldo César Pereira
- Departamento de Ciências Naturais, Universidade Federal de São João del-Rei, UFSJ, São João del-Rei, MG, CEP 36307-352, Brazil.
| | - Lucas Franco Ferreira
- Laboratório de Eletroquímica e Nanotecnologia Aplicada, Instituto de Ciência e Tecnologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Rodovia MGT 367, Km 583, 5000, Alto da Jacuba, Diamantina, MG 39100-000, Brazil
| |
Collapse
|
10
|
Lian M, Shi Y, Zhang W, Zhao J, Chen D. Nitrogen and sulfur co-doped Nb2C-MXene nanosheets for the ultrasensitive electrochemical detection dopamine under acidic conditions in gastric juice. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2021.115849] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
11
|
Huang X, Yang C, Chen Y, Zhu Z, Zhou L. Cuttlefish ink-based N and S co-doped carbon quantum dots as a fluorescent sensor for highly sensitive and selective para-nitrophenol detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:5351-5359. [PMID: 34730132 DOI: 10.1039/d1ay01496j] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Para-nitrophenol (PNP) is an important raw material for organic synthesis and its extensive use has produced a series of environmental problems. Here, we develop a highly sensitive and selective fluorescent detection method for PNP with cuttlefish ink-based carbon quantum dots (CQDs). The cuttlefish ink, which is rich in eumelanin, is utilized as the only precursor to synthesize the CQDs via a one-step hydrothermal method. The resultant CQDs were co-doped with nitrogen and sulfur and exhibited excellent fluorescence properties. Two optimal emissions can be observed at the excitation/emission wavelengths of 320/385 nm and 390/465 nm, respectively. In the presence of PNP, the two emissions are remarkably quenched. PNP can be measured in the linear detection concentration range of 1.25-50 μM (Em = 385 nm and R2 = 0.9884) or 1.25-27.5 μM (Em = 465 nm and R2 = 0.9818) with a detection limit of 0.05 μM. Significantly, it is found that a much wider linear detection range of 0.05-125 μM with a lower detection limit of 0.039 μM (3σ/k) can be achieved when log(I385 nm + I465 nm) was utilized to quantify PNP. The investigations of the sensing mechanism suggested that the inner filter effect and photoinduced electron transfer of PNP and N,S-CQDs leads to fluorescence quenching. The sensing method is successfully applied for PNP detection in real water samples with satisfactory recoveries (91.18-103.14%). A new sustainable waste-prevention strategy of cuttlefish ink and a feasible alternative to PNP detection methods is provided in this article.
Collapse
Affiliation(s)
- Xiaotong Huang
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, 510006, P. R. China.
| | - Chunli Yang
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, 510006, P. R. China.
| | - Yingxin Chen
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, 510006, P. R. China.
| | - Zebin Zhu
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, 510006, P. R. China.
| | - Lihua Zhou
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, 510006, P. R. China.
| |
Collapse
|
12
|
Sun Y, Wei J, Zou J, Cheng Z, Huang Z, Gu L, Zhong Z, Li S, Wang Y, Li P. Electrochemical detection of methyl-paraoxon based on bifunctional cerium oxide nanozyme with catalytic activity and signal amplification effect. J Pharm Anal 2021; 11:653-660. [PMID: 34765279 PMCID: PMC8572677 DOI: 10.1016/j.jpha.2020.09.002] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 09/03/2020] [Accepted: 09/03/2020] [Indexed: 11/29/2022] Open
Abstract
A new electrochemical sensor for organophosphate pesticide (methyl-paraoxon) detection based on bifunctional cerium oxide (CeO2) nanozyme is here reported for the first time. Methyl-paraoxon was degraded into p-nitrophenol by using CeO2 with phosphatase mimicking activity. The CeO2 nanozyme-modified electrode was then synthesized to detect p-nitrophenol. Cyclic voltammetry was applied to investigate the electrochemical behavior of the modified electrode, which indicates that the signal enhancement effect may attribute to the coating of CeO2 nanozyme. The current research also studied and discussed the main parameters affecting the analytical signal, including accumulation potential, accumulation time, and pH. Under the optimum conditions, the present method provided a wider linear range from 0.1 to 100 μmol/L for methyl-paraoxon with a detection limit of 0.06 μmol/L. To validate the proof of concept, the electrochemical sensor was then successfully applied for the determination of methyl-paraoxon in three herb samples, i.e., Coix lacryma-jobi, Adenophora stricta and Semen nelumbinis. Our findings may provide new insights into the application of bifunctional nanozyme in electrochemical detection of organophosphorus pesticide. A new electrochemical method for methyl-paraoxon detection by using bifunctional nanozyme was presented. The cerium oxide nanozyme modified glassy carbon electrode was prepared to improve the sensitivity. The developed method has been successfully applied in three herbal plant samples.
Collapse
Affiliation(s)
- Yuzhou Sun
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macau, 999078, China
| | - Jinchao Wei
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macau, 999078, China.,Institute of Traditional Chinese Medicine & Natural Products, College of Pharmacy, Jinan University; Guangdong Province Key Laboratory of Pharmacodynamic Constituents of TCM and New Drugs Research, Guangzhou, 510632, China
| | - Jian Zou
- Institute of Traditional Chinese Medicine & Natural Products, College of Pharmacy, Jinan University; Guangdong Province Key Laboratory of Pharmacodynamic Constituents of TCM and New Drugs Research, Guangzhou, 510632, China.,Integrated Chinese and Western Medicine Postdoctoral Research Station, Jinan University, Guangzhou, 510632, China
| | - Zehua Cheng
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macau, 999078, China
| | - Zhongming Huang
- Center of Super-Diamond and Advanced Films (COSDAF) and Department of Chemistry, City University of Hong Kong, Hong Kong, 999077, China
| | - Liqiang Gu
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macau, 999078, China
| | - Zhangfeng Zhong
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macau, 999078, China
| | - Shengliang Li
- Center of Super-Diamond and Advanced Films (COSDAF) and Department of Chemistry, City University of Hong Kong, Hong Kong, 999077, China
| | - Yitao Wang
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macau, 999078, China
| | - Peng Li
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macau, 999078, China
| |
Collapse
|
13
|
Karbelkar A, Reynolds EE, Ahlmark R, Furst AL. A Microbial Electrochemical Technology to Detect and Degrade Organophosphate Pesticides. ACS CENTRAL SCIENCE 2021; 7:1718-1727. [PMID: 34729415 PMCID: PMC8554842 DOI: 10.1021/acscentsci.1c00931] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Indexed: 06/13/2023]
Abstract
Organophosphate (OP) pesticides cause hundreds of illnesses and deaths annually. Unfortunately, exposures are often detected by monitoring degradation products in blood and urine, with few effective methods for detection and remediation at the point of dispersal. We have developed an innovative strategy to remediate these compounds: an engineered microbial technology for the targeted detection and destruction of OP pesticides. This system is based upon microbial electrochemistry using two engineered strains. The strains are combined such that the first microbe (E. coli) degrades the pesticide, while the second (S. oneidensis) generates current in response to the degradation product without requiring external electrochemical stimulus or labels. This cellular technology is unique in that the E. coli serves only as an inert scaffold for enzymes to degrade OPs, circumventing a fundamental requirement of coculture design: maintaining the viability of two microbial strains simultaneously. With this platform, we can detect OP degradation products at submicromolar levels, outperforming reported colorimetric and fluorescence sensors. Importantly, this approach affords a modular, adaptable strategy that can be expanded to additional environmental contaminants.
Collapse
Affiliation(s)
- Amruta
A. Karbelkar
- Department
of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, Massachusetts 02139, United States
| | - Erin E. Reynolds
- Department
of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, Massachusetts 02139, United States
| | - Rachel Ahlmark
- Department
of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, Massachusetts 02139, United States
| | - Ariel L. Furst
- Department
of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, Massachusetts 02139, United States
- Center
for Environmental Health Sciences, Massachusetts
Institute of Technology, Cambridge, Massachusetts 02139, United States
| |
Collapse
|
14
|
Yi Z, Kun-Lin Y. Quantitative detection of phenol in wastewater using square wave voltammetry with pre-concentration. Anal Chim Acta 2021; 1178:338788. [PMID: 34482861 DOI: 10.1016/j.aca.2021.338788] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 06/12/2021] [Accepted: 06/20/2021] [Indexed: 10/21/2022]
Abstract
Phenol is a common pollutant found in wastewater, and its allowable discharge limit is 0.5 parts-per-million (ppm). Therefore, it is critical to monitor phenol in the sub-ppm range with high sensitivity and a low limit of detection. Herein, we report a quantitative method for detecting phenol in industrial wastewater through square wave voltammetry (SWV), in which phenol is oxidized to phenoxyl radicals and then became catechol and hydroquinone for detection. By using this method, phenol in the sub-ppm range can be detected reliably over a wide pH range. The sensitivity can be further improved by using a pre-concentration step for phenol before scanning. The method has a limit of detection of 0.1 ppb for phenol. Finally, three graphite electrodes were applied as working, counter and reference electrodes, respectively, in a millifluidic device for continuous detection of phenol in industrial wastewater flowing at 300 μL/min. Because of its simplicity, the sensor can be mass-produced and deployed on a large scale to monitor phenol in industrial wastewater.
Collapse
Affiliation(s)
- Zhang Yi
- Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, 117576, Singapore
| | - Yang Kun-Lin
- Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, 117576, Singapore.
| |
Collapse
|
15
|
Lisboa TP, de Faria LV, Alves GF, Matos MAC, Matos RC. Development of paper devices with conductive inks for sulfanilamide electrochemical determination in milk, synthetic urine, and environmental and pharmaceutical samples. J Solid State Electrochem 2021. [DOI: 10.1007/s10008-021-05002-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
16
|
[Applications of microfluidic paper-based chips in environmental analysis and detection]. Se Pu 2021; 39:802-815. [PMID: 34212581 PMCID: PMC9404056 DOI: 10.3724/sp.j.1123.2020.09004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
近年来,微流控纸芯片由于低成本、便携化、检测快等优点,在需要快速检测的环境分析领域中展现出了巨大的应用前景。该综述从微流控纸芯片在环境分析中的应用角度,总结归纳了微流控纸芯片在环境分析中的最新研究进展,并展望了其在未来的发展趋势与挑战。论文内容引用150余篇源于科学引文索引(SCI)与中文核心期刊中的相关论文。该综述包括微流控纸芯片在环境检测中的优势与制造方法介绍;电化学法、荧光法、比色法、表面增强拉曼法、集成传感法等基于纸芯片的先进分析方法介绍;根据环境分析目标物种类,如重金属离子、营养盐、农药、微生物、抗生素以及其他污染物等,对纸芯片的最新应用现状进行了举例评述;基于微流控纸芯片的环境分析研究的未来发展趋势和前景展望。通过综述近期相关研究,表明微流控纸芯片从提出至今虽然只有十几年的发展历程,但其在环境分析研究中的发展却十分迅速。微流控纸芯片可以根据不同的环境条件和检测要求灵活选择制作与分析方法,实现最佳的检测效果。但是微流控纸芯片也面临一些挑战,如纸张机械强度不足、流体控制程度不佳等问题。这些问题指出了微流控纸芯片在环境检测领域的发展趋势,相信随着不断深入的研究,纸芯片将会在未来的环境分析中发挥更大作用。
Collapse
|
17
|
Noviana E, Ozer T, Carrell CS, Link JS, McMahon C, Jang I, Henry CS. Microfluidic Paper-Based Analytical Devices: From Design to Applications. Chem Rev 2021; 121:11835-11885. [DOI: 10.1021/acs.chemrev.0c01335] [Citation(s) in RCA: 91] [Impact Index Per Article: 30.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Eka Noviana
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Universitas Gadjah Mada, Yogyakarta, Indonesia 55281
| | - Tugba Ozer
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department of Bioengineering, Faculty of Chemical and Metallurgical Engineering, Yildiz Technical University, Istanbul, Turkey 34220
| | - Cody S. Carrell
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Jeremy S. Link
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Catherine McMahon
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Ilhoon Jang
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Institute of Nano Science and Technology, Hanyang University, Seoul, South Korea 04763
| | - Charles S. Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
18
|
Boselli E, Wu Z, Friedman A, Henn BC, Papautsky I. Validation of Electrochemical Sensor for Determination of Manganese in Drinking Water. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:7501-7509. [PMID: 34009956 PMCID: PMC10704915 DOI: 10.1021/acs.est.0c05929] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Manganese (Mn) is an essential nutrient for metabolic functions, yet excessive exposure can lead to neurological disease in adults and neurodevelopmental deficits in children. Drinking water represents one of the routes of excessive Mn exposure. Both natural enrichment from rocks and soil, and man-made contamination can pollute groundwater that supplies drinking water for a substantial fraction of the U.S. population. Conventional methods for Mn monitoring in drinking water are costly and involve a long turn-around time. Recent advancements in electrochemical sensing, however, have led to the development of miniature sensors for Mn determination. These sensors rely on a cathodic stripping voltammetry electroanalytical technique on a miniaturized platinum working electrode. In this study, we validate these electrochemical sensors for the determination of Mn concentrations in drinking water against the standard method using inductively coupled plasma mass spectrometry (ICP-MS). Drinking water samples (n = 78) in the 0.03 ppb to 5.3 ppm range were analyzed. Comparisons with ICP-MS yielded 100% agreement, ∼70% accuracy, and ∼91% precision. We envision the use of our system for rapid and inexpensive point-of-use identification of Mn levels in drinking water, which is especially valuable for frequent monitoring where contamination is present.
Collapse
Affiliation(s)
- Elena Boselli
- Department of Bioengineering, University of Illinois at Chicago, IL
| | - Zhizhen Wu
- Department of Bioengineering, University of Illinois at Chicago, IL
| | - Alexa Friedman
- Department of Environmental Health, Boston University School of Public Health, Boston, MA
| | - Birgit Claus Henn
- Department of Environmental Health, Boston University School of Public Health, Boston, MA
| | - Ian Papautsky
- Department of Bioengineering, University of Illinois at Chicago, IL
| |
Collapse
|
19
|
Ng JS, Hashimoto M. 3D-PAD: Paper-Based Analytical Devices with Integrated Three-Dimensional Features. BIOSENSORS 2021; 11:84. [PMID: 33802637 PMCID: PMC8002416 DOI: 10.3390/bios11030084] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 02/14/2021] [Accepted: 02/16/2021] [Indexed: 11/16/2022]
Abstract
This paper describes the use of fused deposition modeling (FDM) printing to fabricate paper-based analytical devices (PAD) with three-dimensional (3D) features, which is termed as 3D-PAD. Material depositions followed by heat reflow is a standard approach for the fabrication of PAD. Such devices are primarily two-dimensional (2D) and can hold only a limited amount of liquid samples in the device. This constraint can pose problems when the sample consists of organic solvents that have low interfacial energies with the hydrophobic barriers. To overcome this limitation, we developed a method to fabricate PAD integrated with 3D features (vertical walls as an example) by FDM 3D printing. 3D-PADs were fabricated using two types of thermoplastics. One thermoplastic had a low melting point that formed hydrophobic barriers upon penetration, and another thermoplastic had a high melting point that maintained 3D features on the filter paper without reflowing. We used polycaprolactone (PCL) for the former, and polylactic acid (PLA) for the latter. Both PCL and PLA were printed with FDM without gaps at the interface, and the resulting paper-based devices possessed hydrophobic barriers consisting of PCL seamlessly integrated with vertical features consisting of PLA. We validated the capability of 3D-PAD to hold 30 μL of solvents (ethanol, isopropyl alcohol, and acetone), all of which would not be retained on conventional PADs fabricated with solid wax printers. To highlight the importance of containing an increased amount of liquid samples, a colorimetric assay for the formation of dimethylglyoxime (DMG)-Ni (II) was demonstrated using two volumes (10 μL and 30 μL) of solvent-based dimethylglyoxime (DMG). FDM printing of 3D-PAD enabled the facile construction of 3D structures integrated with PAD, which would find applications in paper-based chemical and biological assays requiring organic solvents.
Collapse
Affiliation(s)
- James S. Ng
- Pillar of Engineering Product Development, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore;
| | - Michinao Hashimoto
- Pillar of Engineering Product Development, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore;
- SUTD-MIT International Design Centre, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore
- Digital Manufacturing and Design Centre, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore
| |
Collapse
|
20
|
Pesaran S, Rafatmah E, Hemmateenejad B. An All-in-One Solid State Thin-Layer Potentiometric Sensor and Biosensor Based on Three-Dimensional Origami Paper Microfluidics. BIOSENSORS 2021; 11:44. [PMID: 33579006 PMCID: PMC7916752 DOI: 10.3390/bios11020044] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 02/06/2021] [Accepted: 02/07/2021] [Indexed: 01/13/2023]
Abstract
An origami three-dimensional design of a paper-based potentiometric sensor is described. In its simplest form, this electrochemical paper-based analytical device (ePAD) is made from three small parts of the paper. Paper layers are folded on each other for the integration of a solid contact ion selective electrode (here a carbon-paste composite electrode) and a solid-state pseudo-reference electrode (here writing pencil 6B on the paper), which are in contact with a hydrophilic channel fabricated on the middle part (third part) of the paper. In this case, the pseudo-reference and working electrodes are connected to the two sides of the hydrophilic channel and hence the distance between them is as low as the width of paper. The unmodified carbon paste electrode (UCPE) and modification with the crown ether benzo15-crown-5 (B15C5) represented a very high sensitivity to Cu (II) and Cd2+ ions, respectively. The sensor responded to H2O2 using MnO2-doped carbon paste electrode (CPE). Furthermore, a biosensor was achieved by the addition of glucose oxidase to the MnO2-doped CPE and hence made it selective to glucose with ultra-sensitivity. In addition to very high sensitivity, our device benefits from consuming a very low volume of sample (10.0 µL) and automatic sampling without need for sampling devices.
Collapse
|
21
|
Dabbagh SR, Becher E, Ghaderinezhad F, Havlucu H, Ozcan O, Ozkan M, Yetisen AK, Tasoglu S. Increasing the packing density of assays in paper-based microfluidic devices. BIOMICROFLUIDICS 2021; 15:011502. [PMID: 33569089 PMCID: PMC7864678 DOI: 10.1063/5.0042816] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Accepted: 01/07/2021] [Indexed: 05/04/2023]
Abstract
Paper-based devices have a wide range of applications in point-of-care diagnostics, environmental analysis, and food monitoring. Paper-based devices can be deployed to resource-limited countries and remote settings in developed countries. Paper-based point-of-care devices can provide access to diagnostic assays without significant user training to perform the tests accurately and timely. The market penetration of paper-based assays requires decreased device fabrication costs, including larger packing density of assays (i.e., closely packed features) and minimization of assay reagents. In this review, we discuss fabrication methods that allow for increasing packing density and generating closely packed features in paper-based devices. To ensure that the paper-based device is low-cost, advanced fabrication methods have been developed for the mass production of closely packed assays. These emerging methods will enable minimizing the volume of required samples (e.g., liquid biopsies) and reagents in paper-based microfluidic devices.
Collapse
Affiliation(s)
| | - Elaina Becher
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, USA
| | - Fariba Ghaderinezhad
- Department of Mechanical Engineering, University of Connecticut, Storrs, Connecticut 06269, USA
| | - Hayati Havlucu
- Koç University Arçelik Research Center for Creative Industries (KUAR), Koç University, Sariyer, Istanbul 34450, Turkey
| | - Oguzhan Ozcan
- Koç University Arçelik Research Center for Creative Industries (KUAR), Koç University, Sariyer, Istanbul 34450, Turkey
| | - Mehmed Ozkan
- Boğaziçi Institute of Biomedical Engineering, Boğaziçi University, Çengelköy, Istanbul 34684, Turkey
| | - Ali Kemal Yetisen
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| | | |
Collapse
|
22
|
Murphy M, Manoj D, Saravanakumar D, Thenmozhi K, Senthilkumar S. Water insoluble, self-binding viologen functionalized ionic liquid for simultaneous electrochemical detection of nitrophenol isomers. Anal Chim Acta 2020; 1138:89-98. [DOI: 10.1016/j.aca.2020.09.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 08/19/2020] [Accepted: 09/08/2020] [Indexed: 12/16/2022]
|
23
|
Electrochemical determination of capsaicin in pepper samples using sustainable paper-based screen-printed bulk modified with carbon black. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136628] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
24
|
Ribeiro MFM, Bento F, Ipólito AJ, de Oliveira MF. Development of a Pencil Drawn Paper-based Analytical Device to Detect Lysergic Acid Diethylamide (LSD)* , †. J Forensic Sci 2020; 65:2121-2128. [PMID: 32602943 DOI: 10.1111/1556-4029.14494] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 05/28/2020] [Accepted: 05/29/2020] [Indexed: 01/04/2023]
Abstract
The need for agile and proper identification of drugs of abuse has encouraged the scientific community to improve and to develop new methodologies. The drug lysergic acid diethylamide (LSD) is still widely used due to its hallucinogenic effects. The use of voltammetric methods to analyze narcotics has increased in recent years, and the possibility of miniaturizing the electrochemical equipment allows these methods to be applied outside the laboratory; for example, in crime scenes. In addition to portability, the search for affordable and sustainable materials for use in electroanalytical research has grown in recent decades. In this context, employing paper substrate, graphite pencil, and silver paint to construct paper-based electrodes is a great alternative. Here, a paper-based device comprising three electrodes was drawn on 300 g/m2 watercolor paper with 8B pencils, and its efficiency was compared to the efficiency of a commercially available screen-printed carbon electrode. Square wave voltammetry was used for LSD analysis in aqueous medium containing 0.05 mol/L LiClO4 . The limits of detection and quantification were 0.38 and 1.27 μmol/L, respectively. Both electrodes exhibited a similar voltammetric response, which was also confirmed during analysis of a seized LSD sample, with recovery of less than 10%. The seized samples were previously analyzed by GCMS technique, employing the full scan spectra against the software spectral library. The electrode selectivity was also tested against 3,4-methylenedioxymethamphetamine (MDMA) and methamphetamine. It was possible to differentiate these compounds from LSD, indicating that the developed paper-based device has potential application in forensic chemistry analyses.
Collapse
Affiliation(s)
| | - Fátima Bento
- Centro de Química, Universidade do Minho, Campus de Gualtar, Braga, 4710 - 057, Portugal
| | - Antônio J Ipólito
- Superintendência Polícia Técnica Científica, SPTC, Rua São Sebastião, Ribeirão Preto, SP, 1339, Brazil
| | - Marcelo F de Oliveira
- Universidade de São Paulo, USP, Avenida Bandeirantes, Ribeirão Preto, SP, 3900, Brazil
| |
Collapse
|
25
|
Kaya SI, Karabulut TC, Kurbanoglu S, Ozkan SA. Chemically Modified Electrodes in Electrochemical Drug Analysis. CURR PHARM ANAL 2020. [DOI: 10.2174/1573412915666190304140433] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Electrode modification is a technique performed with different chemical and physical methods
using various materials, such as polymers, nanomaterials and biological agents in order to enhance
sensitivity, selectivity, stability and response of sensors. Modification provides the detection of small
amounts of analyte in a complex media with very low limit of detection values. Electrochemical methods
are well suited for drug analysis, and they are all-purpose techniques widely used in environmental
studies, industrial fields, and pharmaceutical and biomedical analyses. In this review, chemically modified
electrodes are discussed in terms of modification techniques and agents, and recent studies related
to chemically modified electrodes in electrochemical drug analysis are summarized.
Collapse
Affiliation(s)
- Sariye I. Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Tutku C. Karabulut
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Sevinç Kurbanoglu
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Sibel A. Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
26
|
Mazurkiewicz W, Podrażka M, Jarosińska E, Kappalakandy Valapil K, Wiloch M, Jönsson‐Niedziółka M, Witkowska Nery E. Paper‐Based Electrochemical Sensors and How to Make Them (Work). ChemElectroChem 2020. [DOI: 10.1002/celc.202000512] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Wojciech Mazurkiewicz
- Institute of Physical ChemistryPolish Academy of Sciences Kasprzaka 44/52 01-224 Warsaw Poland
| | - Marta Podrażka
- Institute of Physical ChemistryPolish Academy of Sciences Kasprzaka 44/52 01-224 Warsaw Poland
| | - Elżbieta Jarosińska
- Institute of Physical ChemistryPolish Academy of Sciences Kasprzaka 44/52 01-224 Warsaw Poland
| | | | - Magdalena Wiloch
- Institute of Physical ChemistryPolish Academy of Sciences Kasprzaka 44/52 01-224 Warsaw Poland
| | | | - Emilia Witkowska Nery
- Institute of Physical ChemistryPolish Academy of Sciences Kasprzaka 44/52 01-224 Warsaw Poland
| |
Collapse
|
27
|
Puiu M, Bala C. Microfluidics-integrated biosensing platforms as emergency tools for on-site field detection of foodborne pathogens. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115831] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
28
|
Laghrib F, Houcini H, Khalil F, Liba A, Bakasse M, Lahrich S, El Mhammedi MA. Synthesis of Silver Nanoparticles Using Chitosan as Stabilizer Agent: Application towards Electrocatalytical Reduction of p‐Nitrophenol. ChemistrySelect 2020. [DOI: 10.1002/slct.201903955] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- F. Laghrib
- Sultan Moulay Slimane University of Beni MellalLaboratory of Chemistry, Modeling and Environmental Sciences, Polydisciplinary faculty 25 000 Khouribga Morocco
| | - H. Houcini
- Sultan Moulay Slimane University of Beni MellalLaboratory of Chemistry, Modeling and Environmental Sciences, Polydisciplinary faculty 25 000 Khouribga Morocco
| | - F. Khalil
- Univ. Sidi Mohamed Ben AbdellahLaboratory of Applied Chemistry (LCA), Faculty of Science and Technology Immouzer Road, BP 2202 Fez Morocco
| | - A. Liba
- Univ. Sultan Moulay Slimane, Materials Physics LaboratoryFaculty of Science and Technology Beni Mellal Morocco
| | - M. Bakasse
- Sultan Moulay Slimane University of Beni MellalLaboratory of Chemistry, Modeling and Environmental Sciences, Polydisciplinary faculty 25 000 Khouribga Morocco
- Chouaib Doukkali UniversityFaculty of Sciences, Laboratory of Organic Bioorganic Chemistry and Environment El Jadida Morocco
| | - S. Lahrich
- Sultan Moulay Slimane University of Beni MellalLaboratory of Chemistry, Modeling and Environmental Sciences, Polydisciplinary faculty 25 000 Khouribga Morocco
| | - M. A. El Mhammedi
- Sultan Moulay Slimane University of Beni MellalLaboratory of Chemistry, Modeling and Environmental Sciences, Polydisciplinary faculty 25 000 Khouribga Morocco
| |
Collapse
|
29
|
Noviana E, McCord CP, Clark KM, Jang I, Henry CS. Electrochemical paper-based devices: sensing approaches and progress toward practical applications. LAB ON A CHIP 2020; 20:9-34. [PMID: 31620764 DOI: 10.1039/c9lc00903e] [Citation(s) in RCA: 140] [Impact Index Per Article: 35.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Paper-based sensors offer an affordable yet powerful platform for field and point-of-care (POC) testing due to their self-pumping ability and utility for many different analytical measurements. When combined with electrochemical detection using small and portable electronics, sensitivity and selectivity of the paper devices can be improved over naked eye detection without sacrificing portability. Herein, we review how the field of electrochemical paper-based analytical devices (ePADs) has grown since it was introduced a decade ago. We start by reviewing fabrication methods relevant to ePADs with more focus given to the electrode fabrication, which is fundamental for electrochemical sensing. Multiple sensing approaches applicable to ePADs are then discussed and evaluated to present applicability, advantages and challenges associated with each approach. Recent applications of ePADs in the fields of clinical diagnostics, environmental testing, and food analysis are also presented. Finally, we discuss how the current ePAD technologies have progressed to meet the analytical and practical specifications required for field and/or POC applications, as well as challenges and outlook.
Collapse
Affiliation(s)
- Eka Noviana
- Department of Chemistry, Colorado State University, Fort Collins, CO, USA. and Department of Pharmaceutical Chemistry, School of Pharmacy, Universitas Gadjah Mada, Yogyakarta, Indonesia
| | - Cynthia P McCord
- Department of Chemistry, Colorado State University, Fort Collins, CO, USA.
| | - Kaylee M Clark
- Department of Chemistry, Colorado State University, Fort Collins, CO, USA.
| | - Ilhoon Jang
- Department of Chemistry, Colorado State University, Fort Collins, CO, USA. and Institute of Nano Science and Technology, Hanyang University, Seoul, South Korea
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, CO, USA.
| |
Collapse
|
30
|
Tammina SK, Yang Y. Highly sensitive and selective detection of 4-nitrophenol, and on-off-on fluorescence sensor for Cr (VI) and ascorbic acid detection by glucosamine derived n-doped carbon dots. J Photochem Photobiol A Chem 2020. [DOI: 10.1016/j.jphotochem.2019.112134] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
31
|
Mobed A, Hasanzadeh M, Shadjou N, Hassanpour S, Saadati A, Agazadeh M. Immobilization of ssDNA on the surface of silver nanoparticles-graphene quantum dots modified by gold nanoparticles towards biosensing of microorganism. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104286] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
32
|
Ng JS, Hashimoto M. Fabrication of paper microfluidic devices using a toner laser printer. RSC Adv 2020; 10:29797-29807. [PMID: 35518222 PMCID: PMC9056319 DOI: 10.1039/d0ra04301j] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 07/23/2020] [Indexed: 12/23/2022] Open
Abstract
This paper describes a method to fabricate microfluidic paper-based analytical devices (μPADs) using a toner laser printer. Multiple methods have been reported for the fabrication of μPADs for point-of-care diagnostics and environmental monitoring. Despite successful demonstrations, however, existing fabrication methods depend on particular printers, in-house instruments, and synthetic materials. In particular, recent discontinuation of the solid wax printer has made it difficult to fabricate μPADs with readily available instruments. Herein we reported the fabrication of μPADs using the most widely available type of printer: a toner laser printer. Heating of printed toner at 200 °C allowed the printed toner to reflow, and the spreading of the hydrophobic polymer through the filter paper was characterized. Using the developed μPADs, we conducted model colorimetric assays for glucose and bovine serum albumin (BSA). We found that heating of filter paper at 200 °C for 60 min caused the pyrolysis of cellulose in the paper. The pyrolysis resulted in the formation of aldehydes that could interfere with molecular assays involving redox reactions. To overcome this problem, we confirmed that the removal of the aldehyde could be readily achieved by washing the μPADs with aqueous bleach. Overall, the developed fabrication method should be compatible with most toner laser printers and will make μPADs accessible in resource-limited circumstances. We developed a method to fabricate microfluidic paper-based analytical devices (μPADs) using a toner laser printer. We addressed a potential problem of pyrolysis that resulted from long duration of heating required for the penetration of the toner.![]()
Collapse
Affiliation(s)
- James S. Ng
- Pillar of Engineering Product Development
- Singapore University of Technology and Design
- Singapore
- Singapore
| | - Michinao Hashimoto
- Pillar of Engineering Product Development
- Singapore University of Technology and Design
- Singapore
- Singapore
- SUTD-MIT International Design Centre
| |
Collapse
|
33
|
Dias AA, Chagas CLS, Silva-Neto HDA, Lobo-Junior EO, Sgobbi LF, de Araujo WR, Paixão TRLC, Coltro WKT. Environmentally Friendly Manufacturing of Flexible Graphite Electrodes for a Wearable Device Monitoring Zinc in Sweat. ACS APPLIED MATERIALS & INTERFACES 2019; 11:39484-39492. [PMID: 31524381 DOI: 10.1021/acsami.9b12797] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Electrochemical sensors based on graphite and polymers have emerged as powerful analytical tools for bioanalytical applications. However, most of the fabrication processes are not environmentally friendly because they often involve the use of toxic reagents and generate waste. This study describes an alternative method to produce flexible electrodes in plastic substrates using graphite powder and thermal laminating sheets by solid-solid deposition through hot compression, without the use of hazardous chemical reagents. The electrodes developed through the proposed approach have successfully demonstrated flexibility, robustness, reproducibility (relative standard deviation around 6%), and versatility. The electrodes were thoroughly characterized by cyclic voltammetry, electrochemical impedance spectroscopy, Raman spectroscopy, and scanning electron microscopy. As a proof of concept, the electrode surfaces were modified with bismuth and used for zinc analysis in sweat. The modified electrodes presented linearity (R2 = 0.996) for a wide zinc concentration range (50-2000 ppb) and low detection limit (4.31 ppb). The proposed electrodes were tested using real sweat samples and the achieved zinc concentrations did not differ statistically from the data obtained by atomic absorption spectroscopy. To allow wearable applications, a 3D-printed device was fabricated, integrated with the proposed electrochemical system, and fixed at the abdomen by using an elastic tape to collect, store, and analyze the sweat sample. The matrix effect test was performed, spiking the real sample with different zinc levels, and the recovery values varied between 85 and 106%, thus demonstrating adequate accuracy and robustness of the flexible electrodes developed based on the proposed fabrication method.
Collapse
Affiliation(s)
- Anderson A Dias
- Instituto de Química , Universidade Federal de Goiás , Goiânia , Goiás 74690-900 , Brazil
| | - Cyro L S Chagas
- Departamento de Química Fundamental, Instituto de Química , Universidade de São Paulo , São Paulo , São Paulo 05508-000 , Brazil
| | | | - Eulício O Lobo-Junior
- Instituto de Química , Universidade Federal de Goiás , Goiânia , Goiás 74690-900 , Brazil
| | - Lívia F Sgobbi
- Instituto de Química , Universidade Federal de Goiás , Goiânia , Goiás 74690-900 , Brazil
| | - William R de Araujo
- Departamento de Química Analítica, Instituto de Química , Universidade Estadual de Campinas , Campinas , São Paulo 13083-970 , Brazil
| | - Thiago R L C Paixão
- Departamento de Química Fundamental, Instituto de Química , Universidade de São Paulo , São Paulo , São Paulo 05508-000 , Brazil
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica , Campinas , São Paulo 13084-971 , Brazil
| | - Wendell K T Coltro
- Instituto de Química , Universidade Federal de Goiás , Goiânia , Goiás 74690-900 , Brazil
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica , Campinas , São Paulo 13084-971 , Brazil
| |
Collapse
|
34
|
Chronometric Quantitation of Analytes in Paper-Based Microfluidic Devices (MicroPADs) via Enzymatic Degradation of a Metastable Biomatrix. INVENTIONS 2019. [DOI: 10.3390/inventions4030048] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The following article summarizes United States Patent Application No. US20180052155A1, titled ‘Assay Devices and Methods’ (filed 16 August 2016, published 22 February 2018). While lateral flow assays (LFAs) have revolutionized point-of-care diagnostics by enabling accurate, inexpensive, and rapid detection of biomarkers, they typically do not provide quantitative results. Hence, there is a significant need for quantitative assays at the point of care. This patent summary describes a novel method of chronometric biomarker quantitation via enzymatic degradation of a metastable gelatin-based biomatrix, principally suited for use in paper-based microfluidic devices (microPADs). This new quantitation mechanism was designed to meet the ASSURED criteria for point-of-care diagnostic devices laid forth by the World Health Organization and may ultimately provide increased access to healthcare, at a significantly reduced cost, around the world.
Collapse
|
35
|
Mejri A, Mars A, Elfil H, Hamzaoui AH. Voltammetric simultaneous quantification of p-nitrophenol and hydrazine by using magnetic spinel FeCo2O4 nanosheets on reduced graphene oxide layers modified with curcumin-stabilized silver nanoparticles. Mikrochim Acta 2019; 186:561. [DOI: 10.1007/s00604-019-3650-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Accepted: 07/01/2019] [Indexed: 12/15/2022]
|
36
|
A voltammetric carbon paste sensor modified with NiO nanoparticle and ionic liquid for fast analysis of p-nitrophenol in water samples. J Mol Liq 2019. [DOI: 10.1016/j.molliq.2019.04.084] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
37
|
Ozcelikay G, Karadurmus L, Kaya SI, Bakirhan NK, Ozkan SA. A Review: New Trends in Electrode Systems for Sensitive Drug and Biomolecule Analysis. Crit Rev Anal Chem 2019; 50:212-225. [PMID: 31107105 DOI: 10.1080/10408347.2019.1615406] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Drug and biomolecule analysis with high precision, fast response, not expensive, and user-friendly methods have been very important for developing technology and clinical applications. Electrochemical methods are highly capable for assaying the concentration of electroactive drug or biomolecule and supply excellent knowledge concerning its physical and chemical properties such as electron transfer rates, diffusion coefficients, electron transfer number, and oxidation potential. Electrochemical methods have been widely applied because of their accuracy, sensitivity, cheapness, and can applied on-site determinations of various substances. The progress on electronics has allowed developing reliable, more sensitive and less expensive instrumentations, which have significant contribution in the area of drug development, drug and biomolecule analysis. The developing new sensors for electrochemical analysis of these compounds have growing interest in recent years. Screen-printed based electrodes have a great interest in electrochemical analysis of various drugs and biomolecules due to their easy manufacturing procedure of the electrode allow the transfer of electrochemical laboratory experiments for disposable on-site analysis of some compounds. Paper based electrodes are also fabricated by new technology. They can be preferred due to their easy, cheap, portable, disposable, and offering high sensitivity properties for many application field such as environmental monitoring, food quality control, clinical diagnosis, drug, and biomolecules analysis. In this review, the recent electrochemical drug and biomolecule (DNA, RNA, µRNA, Biomarkers, etc.) studies will be presented that involve new trend disposable electrodes.
Collapse
Affiliation(s)
- Goksu Ozcelikay
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Leyla Karadurmus
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey.,Department of Analytical Chemistry, Faculty of Pharmacy, Adıyaman University, Adıyaman, Turkey
| | - S Irem Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Nurgul K Bakirhan
- Department of Chemistry, Arts & Sciences Faculty, Hitit University, Corum, Turkey
| | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
38
|
Fu X, Xia B, Ji B, Lei S, Zhou Y. Flow controllable three-dimensional paper-based microfluidic analytical devices fabricated by 3D printing technology. Anal Chim Acta 2019; 1065:64-70. [PMID: 31005152 DOI: 10.1016/j.aca.2019.02.046] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 02/27/2019] [Indexed: 01/21/2023]
Abstract
In most cases, three-dimensional paper-based microfluidic analytical devices (3D-μPADs) were fabricated manually by stacking or folding methods. For the first time, digital light processing stereolithography (DLP-SLA) 3D printing technology was adopted to automatically make 3D-μPADs. In the fabrication process, a printing pause was set between two layers to allow paper to be placed in the resin tank. The resin on the fresh paper spontaneously bonded to the former cured paper layer during curing, thus realizing the automatic bonding and alignment between different layers of paper and avoiding the human participation and errors as in stacking and folding methods. There was a gap between two vertical aligned flow paths, therefore the liquid did not flow spontaneously from the upper layer to the lower layer. Most of the fluid flow in 3D-μPADs was spontaneous or manually activated, which was not conducive to complex assays that require different regents to be delivered sequentially. Herein, we used an electric field or airflow to trigger the fluid flow and demonstrated the flow controllability by a proof-of-concept colorimetric assay. The limits of detection of glucose and albumin were 0.8 mM and 3.5 μM, respectively, which were sufficient for clinical requirements. Given the characteristic of flow controllability, we believe that the proposed 3D-μPADs have great potential to make paper-based complex assays automated and programmable.
Collapse
Affiliation(s)
- Xian Fu
- Chengdu Institute of Biology, Chinese Academy of Sciences, No. 93 South Keyuan Road, Gaoxin Distinct, Chengdu, 610041, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Bing Xia
- Chengdu Institute of Biology, Chinese Academy of Sciences, No. 93 South Keyuan Road, Gaoxin Distinct, Chengdu, 610041, PR China
| | - Baocheng Ji
- Chengdu Institute of Biology, Chinese Academy of Sciences, No. 93 South Keyuan Road, Gaoxin Distinct, Chengdu, 610041, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Shan Lei
- Chengdu Institute of Biology, Chinese Academy of Sciences, No. 93 South Keyuan Road, Gaoxin Distinct, Chengdu, 610041, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Yan Zhou
- Chengdu Institute of Biology, Chinese Academy of Sciences, No. 93 South Keyuan Road, Gaoxin Distinct, Chengdu, 610041, PR China.
| |
Collapse
|
39
|
GAMA MARIANAR, MELCHERT WANESSAR, PAIXÃO THIAGOR, ROCHA FÁBIOR. An overview of the Brazilian contributions to Green Analytical Chemistry. ACTA ACUST UNITED AC 2019; 91:e20180294. [DOI: 10.1590/0001-3765201920180294] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Accepted: 04/17/2018] [Indexed: 12/11/2022]
|
40
|
Gebretsadik T, Belayneh T, Gebremichael S, Linert W, Thomas M, Berhanu T. Recent advances in and potential utilities of paper-based electrochemical sensors: beyond qualitative analysis. Analyst 2019; 144:2467-2479. [DOI: 10.1039/c8an02463d] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Paper based electrochemical sensors (PESs) are simple, low-cost, portable and disposable analytical sensing platforms that can be applied in clinical diagnostics, food quality control and environmental monitoring.
Collapse
Affiliation(s)
- Tesfay Gebretsadik
- Department of Industrial Chemistry
- Addis Ababa Science and Technology University
- Addis Ababa
- Ethiopia
| | - Tilahun Belayneh
- Department of Industrial Chemistry
- Addis Ababa Science and Technology University
- Addis Ababa
- Ethiopia
| | - Sosina Gebremichael
- Department of Industrial Chemistry
- Addis Ababa Science and Technology University
- Addis Ababa
- Ethiopia
| | - Wolfgang Linert
- Institute of Applied Synthetic Chemistry
- Vienna University of Technology
- A-1060 Vienna
- Austria
| | - Madhu Thomas
- Department of Industrial Chemistry
- Addis Ababa Science and Technology University
- Addis Ababa
- Ethiopia
| | - Tarekegn Berhanu
- Department of Industrial Chemistry
- Addis Ababa Science and Technology University
- Addis Ababa
- Ethiopia
| |
Collapse
|
41
|
Pencil Lead as a Material for Microfluidic 3D-Electrode Assemblies. SENSORS 2018; 18:s18114037. [PMID: 30463263 PMCID: PMC6264025 DOI: 10.3390/s18114037] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 11/13/2018] [Accepted: 11/15/2018] [Indexed: 01/09/2023]
Abstract
We present an electrochemical, microfluidic system with a working electrode based on an ordered 3D array of pencil leads. The electrode array was integrated into a plexiglass/PDMS channel. We tested the setup using a simple redox probe and compared the results with computer simulations. As a proof of concept application of the device we showed that the setup can be used for determination of dopamine concentration in physiological pH and ultrasensitive, although only qualitative, detection of p-nitrophenol with a limit of detection below 1 nmol L−1. The observed limit of detection for p-nitrophenol is not only much lower than achieved with similar methods but also sufficient for evaluation of exposure to pesticides such as methyl parathion through urinalysis. This low cost setup can be fabricated without the need for clean room facilities and in the future, due to the ordered structure of the electrode could be used to better understand the process of electroanalysis and electrode functionalization. To the best of our knowledge it is the first application of pencil leads as 3D electrochemical sensor in a microfluidic channel.
Collapse
|
42
|
Forman JE, Timperley CM, Aas P, Abdollahi M, Alonso IP, Baulig A, Becker-Arnold R, Borrett V, Cariño FA, Curty C, Gonzalez D, Kovarik Z, Martínez-Álvarez R, Mikulak R, de Souza Nogueria E, Ramasami P, Raza SK, Saeed AEM, Takeuchi K, Tang C, Trifirò F, van Straten FM, Waqar F, Zaitsev V, Zina MS, Grolmusová K, Valente G, Payva M, Sun S, Yang A, van Eerten D. Innovative technologies for chemical security. PURE APPL CHEM 2018. [DOI: 10.1515/pac-2018-0908] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Abstract
Advances across the chemical and biological (life) sciences are increasingly enabled by ideas and tools from sectors outside these disciplines, with information and communication technologies playing a key role across 21st century scientific development. In the face of rapid technological change, the Organisation for the Prohibition of Chemical Weapons (OPCW), the implementing body of the Chemical Weapons Convention (“the Convention”), seeks technological opportunities to strengthen capabilities in the field of chemical disarmament. The OPCW Scientific Advisory Board (SAB) in its review of developments in science and technology examined the potential uses of emerging technologies for the implementation of the Convention at a workshop entitled “Innovative Technologies for Chemical Security”, held from 3 to 5 July 2017, in Rio de Janeiro, Brazil. The event, organized in cooperation with the International Union of Pure and Applied Chemistry (IUPAC), the National Academies of Science, Engineering and Medicine of the United States of America, the Brazilian Academy of Sciences, and the Brazilian Chemical Society, was attended by 45 scientists and engineers from 22 countries. Their insights into the use of innovative technological tools and how they might benefit chemical disarmament and non-proliferation informed the SAB’s report on developments in science and technology for the Fourth Review Conference of the Convention (to be held in November 2018), and are described herein, as are recommendations that the SAB submitted to the OPCW Director-General and the States Parties of the Convention. It is concluded that technologies exist or are under development that could be used for investigations, contingency, assistance and protection, reducing risks to inspectors, and enhancing sampling and analysis.
Collapse
Affiliation(s)
- Jonathan E. Forman
- Secretary to the Scientific Advisory Board and Science Policy Adviser, Organisation for the Prohibition of Chemical Weapons (OPCW) , The Hague , The Netherlands
| | - Christopher M. Timperley
- Defence Science and Technology Laboratory (DSTL), Porton Down, Salisbury , Wiltshire, SP4 0JQ , UK
| | - Pål Aas
- Norwegian Defence Research Establishment (FFI) , Kjeller , Norway
| | - Mohammad Abdollahi
- Toxicology and Diseases Group, The Institute of Pharmaceutical Sciences (TIPS), Tehran University of Medical Sciences , Tehran , The Islamic Republic of Iran
| | | | - Augustin Baulig
- Secrétariat Général de la Défense et de la Sécurité Nationale (SGDSN) , Paris , France
| | | | - Veronica Borrett
- BAI Scientific , Melbourne , Australia ; and Honorary Fellow, University of Melbourne , Melbourne , Australia
| | - Flerida A. Cariño
- Institute of Chemistry, University of the Philippines , Quezon City , Philippines
| | | | - David Gonzalez
- Facultad de Química, Universidad de la República , Montevideo , Uruguay
| | - Zrinka Kovarik
- Institute for Medical Research and Occupational Health , Zagreb , Croatia
| | | | - Robert Mikulak
- United States Department of State , Washington, DC , USA
| | - Evandro de Souza Nogueria
- Brazilian Ministry of Science, Technology, Innovation and Communications (MCTIC) , Brasilia , Brazil
| | - Ponnadurai Ramasami
- Computational Chemistry Group, Department of Chemistry , Faculty of Science, University of Mauritius , Réduit 80837 , Mauritius
| | - Syed K. Raza
- Institute of Pesticides Formulation Technology (IPFT) , Gurugram, Haryana , India
| | | | - Koji Takeuchi
- National Institute of Advanced Industrial Science and Technology (AIST) , Tokyo , Japan
| | - Cheng Tang
- Office for the Disposal of Japanese Abandoned Chemical Weapons, Ministry of National Defence , Beijing , China
| | - Ferruccio Trifirò
- Department of Industrial Chemistry , University of Bologna , Bologna , Italy
| | | | - Farhat Waqar
- Pakistan Atomic Energy Commission , Islamabad , Pakistan
| | - Volodymyr Zaitsev
- Taras Shevchenko National University of Kyiv , Kyiv , Ukraine ; and Pontifical Catholic University of Rio de Janeiro , Rio de Janeiro , Brazil
| | | | | | - Guy Valente
- Assistance and Protection Branch, OPCW , The Hague , The Netherlands
| | - Marlene Payva
- Office of Strategy and Policy, OPCW , The Hague , The Netherlands
| | - Siqing Sun
- Interns in the Office of Strategy and Policy, OPCW , The Hague , The Netherlands
| | - Amy Yang
- Interns in the Office of Strategy and Policy, OPCW , The Hague , The Netherlands
| | - Darcy van Eerten
- Interns in the Office of Strategy and Policy, OPCW , The Hague , The Netherlands
| |
Collapse
|
43
|
Gaines M, Gonzalez-Guerrero MJ, Uchida K, Gomez FA. Microfluidic thread-based electrode system to detect glucose and acetylthiocholine. Electrophoresis 2018; 39:3082-3086. [PMID: 30232815 DOI: 10.1002/elps.201800348] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Revised: 09/05/2018] [Accepted: 09/11/2018] [Indexed: 11/07/2022]
Abstract
A reusable and simple to fabricate electrochemical sensor for the detection of glucose and acetylthiocholine using thread-based electrodes and nylon thread is described. The fabrication of the device consisted of two steps. First, three nylon-based electrodes (reference, working, and counter) were painted with one layer of conductive inks (silver and carbon ink, or silver/silver chloride ink). The electrodes were taped onto parafilm, and a piece of white nylon thread was wrapped around each electrode connecting the three electrodes. For the glucose system, a PBS solution containing glucose oxidase (GOx) (10 mg/mL), and potassium ferricyanide (K3 [Fe(CN)6 ]) (10 mg/mL) as mediator, was dried onto the thread, and increasing concentrations of glucose (0-15 mM) was added to the thread and measured by cyclic voltammetry (CV). The current output from the glucose oxidation was proportional to the concentration of glucose. For the second system, a solution of acetylcholinesterase (AChE) (0.08 U/mL) in PBS was added to the nylon thread, and increasing concentrations of acetylthiocholine (ATC) (0-9.84 mg/mL) was added and measured by CV. The current output from the oxidation of thiocholine (produced by AChE reacting with ATC) was proportional to the concentrations of ATC added to the thread. From both systems, a graph of current output versus substrate concentration was produced and fitted with a linear regression line that gave R2 values of 0.985 (GOX /glucose) and 0.995 (AChE/ATC).
Collapse
Affiliation(s)
- Michelle Gaines
- Department of Chemistry and Biochemistry, California State University, Los Angeles, CA, USA
| | | | - Kathryn Uchida
- Department of Chemistry and Biochemistry, California State University, Los Angeles, CA, USA
| | - Frank A Gomez
- Department of Chemistry and Biochemistry, California State University, Los Angeles, CA, USA
| |
Collapse
|
44
|
Paschoalino WJ, Kogikoski S, Barragan JTC, Giarola JF, Cantelli L, Rabelo TM, Pessanha TM, Kubota LT. Emerging Considerations for the Future Development of Electrochemical Paper-Based Analytical Devices. ChemElectroChem 2018. [DOI: 10.1002/celc.201800677] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Waldemir J. Paschoalino
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Sergio Kogikoski
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - José T. C. Barragan
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Juliana F. Giarola
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Lory Cantelli
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Thais M. Rabelo
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Tatiana M. Pessanha
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| | - Lauro T. Kubota
- Department of Analytical Chemistry, Institute of Chemistry; State University of Campinas (UNICAMP); P.O. Box 6154 13083-970 Campinas-SP Brazil
| |
Collapse
|
45
|
Dias AA, Cardoso TMG, Chagas CLS, Oliveira VXG, Munoz RAA, Henry CS, Santana MHP, Paixão TRLC, Coltro WKT. Detection of Analgesics and Sedation Drugs in Whiskey Using Electrochemical Paper-based Analytical Devices. ELECTROANAL 2018. [DOI: 10.1002/elan.201800308] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Affiliation(s)
- Anderson A. Dias
- Instituto de Química; Universidade Federal de Goiás; Goiânia, GO 74690-900 Brazil
| | - Thiago M. G. Cardoso
- Instituto de Química; Universidade Federal de Goiás; Goiânia, GO 74690-900 Brazil
| | - Cyro L. S. Chagas
- Instituto de Química; Universidade Federal de Goiás; Goiânia, GO 74690-900 Brazil
| | | | - Rodrigo A. A. Munoz
- Instituto de Química; Universidade Federal de Uberlândia; Uberlândia, MG 38408-100 Brazil
| | - Charles S. Henry
- Department of Chemistry; Colorado State University; Fort Collins, CO 80523 United States of America
| | - Mário H. P. Santana
- Unidade Técnico-Científica -; Superintendência Regional da Polícia Federal em MG; Uberlândia, MG 38408-6630 Brazil
| | - Thiago R. L. C. Paixão
- Departamento de Química Fundamental, Instituto de Química; Universidade de São Paulo; 05508-000 São Paulo, SP Brazil
| | - Wendell K. T. Coltro
- Instituto de Química; Universidade Federal de Goiás; Goiânia, GO 74690-900 Brazil
| |
Collapse
|
46
|
Xiao N, Liu SG, Mo S, Li N, Ju YJ, Ling Y, Li NB, Luo HQ. Highly selective detection of p-nitrophenol using fluorescence assay based on boron, nitrogen co-doped carbon dots. Talanta 2018; 184:184-192. [PMID: 29674031 DOI: 10.1016/j.talanta.2018.02.114] [Citation(s) in RCA: 82] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Revised: 02/22/2018] [Accepted: 02/28/2018] [Indexed: 01/18/2023]
Abstract
p-Nitrophenol (p-NP) contaminants seriously endanger environmental and living beings health, hence to establish a sensitive and selective method is of great importance for the determination of p-NP. In this work, boron and nitrogen co-doped carbon dots (B,N-CDs) were synthesized by one-step hydrothermal method using 3-aminophenylboronic acid as the sole precursor. The product was characterized through high-resolution transmission electron microscopy, fluorescence spectroscopy, UV-visible absorption spectroscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. Without any functionalized modification, B,N-CDs can be directly applied as a 'turn-off' fluorescent probe for rapid, highly selective, and sensitive detection of p-NP. The fluorescent sensor based on the B,N-CDs exhibited a broad linear response to the concentration of p-NP in the range of 0.5 - 60 μM and 60 - 200 μM, respectively, and provided a detection limit of 0.2 μM. It was found that only the absorption spectrum of p-NP has a wide overlap with the fluorescence excitation and emission spectra of B,N-CDs compared to those of other representative analogues. The response mechanism was due to the inner filter effect and the formation of dynamic covalent B-O bonds between B,N-CDs and p-NP, which endowed the sensing platform with the rapid response and high selectivity to p-NP. Finally, the sensor showed the practicability of p-NP determination in environmental water samples.
Collapse
Affiliation(s)
- Na Xiao
- Key Laboratory of Eco-Environments in Three Gorges Reservoir Region (Ministry of Education), School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China
| | - Shi Gang Liu
- Key Laboratory of Eco-Environments in Three Gorges Reservoir Region (Ministry of Education), School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China
| | - Shi Mo
- Department of Physics, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China
| | - Na Li
- Key Laboratory of Eco-Environments in Three Gorges Reservoir Region (Ministry of Education), School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China
| | - Yan Jun Ju
- Key Laboratory of Eco-Environments in Three Gorges Reservoir Region (Ministry of Education), School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China
| | - Yu Ling
- Key Laboratory of Eco-Environments in Three Gorges Reservoir Region (Ministry of Education), School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China
| | - Nian Bing Li
- Key Laboratory of Eco-Environments in Three Gorges Reservoir Region (Ministry of Education), School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China.
| | - Hong Qun Luo
- Key Laboratory of Eco-Environments in Three Gorges Reservoir Region (Ministry of Education), School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China.
| |
Collapse
|
47
|
Paper-based amperometric sensor for determination of acetylcholinesterase using screen-printed graphene electrode. Talanta 2018; 178:1017-1023. [DOI: 10.1016/j.talanta.2017.08.096] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Revised: 08/24/2017] [Accepted: 08/24/2017] [Indexed: 11/22/2022]
|
48
|
Akyazi T, Basabe-Desmonts L, Benito-Lopez F. Review on microfluidic paper-based analytical devices towards commercialisation. Anal Chim Acta 2018; 1001:1-17. [DOI: 10.1016/j.aca.2017.11.010] [Citation(s) in RCA: 311] [Impact Index Per Article: 51.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Revised: 10/23/2017] [Accepted: 11/03/2017] [Indexed: 12/20/2022]
|
49
|
Almeida MIG, Jayawardane BM, Kolev SD, McKelvie ID. Developments of microfluidic paper-based analytical devices (μPADs) for water analysis: A review. Talanta 2018; 177:176-190. [DOI: 10.1016/j.talanta.2017.08.072] [Citation(s) in RCA: 160] [Impact Index Per Article: 26.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Revised: 08/21/2017] [Accepted: 08/23/2017] [Indexed: 11/27/2022]
|
50
|
da Silva ETSG, Alves TMR, Kubota LT. Direct Toner Printing: A Versatile Technology for Easy Fabrication of Flexible Miniaturized Electrodes. ELECTROANAL 2017. [DOI: 10.1002/elan.201700717] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Everson T. S. G. da Silva
- Department of Analytical Chemistry; Institute of Chemistry-UNICAMP; P.O. Box 6154, 13084-974 Campinas-SP, Brazil
- National Institute of Science and Technology of Bioanalytics (INCTBio); 13083-970 Campinas-SP Brazil
| | - Thais M. R. Alves
- Department of Analytical Chemistry; Institute of Chemistry-UNICAMP; P.O. Box 6154, 13084-974 Campinas-SP, Brazil
- National Institute of Science and Technology of Bioanalytics (INCTBio); 13083-970 Campinas-SP Brazil
| | - Lauro T. Kubota
- Department of Analytical Chemistry; Institute of Chemistry-UNICAMP; P.O. Box 6154, 13084-974 Campinas-SP, Brazil
- National Institute of Science and Technology of Bioanalytics (INCTBio); 13083-970 Campinas-SP Brazil
| |
Collapse
|