1
|
Mostafa-Hedeab G, Allayeh AK, Elhady HA, Eledrdery AY, Mraheil MA, Mostafa A. Viral Eco-Genomic Tools: Development and Implementation for Aquatic Biomonitoring. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:7707. [PMID: 35805367 PMCID: PMC9265447 DOI: 10.3390/ijerph19137707] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2022] [Revised: 06/21/2022] [Accepted: 06/21/2022] [Indexed: 12/17/2022]
Abstract
Enteric viruses (EVs) occurrence within aquatic environments varies and leads to significant risk on public health of humans, animals, and diversity of aquatic taxa. Early and efficacious recognition of cultivable and fastidious EVs in aquatic systems are important to ensure the sanitary level of aquatic water and implement required treatment strategies. Herein, we provided a comprehensive overview of the conventional and up-to-date eco-genomic tools for aquatic biomonitoring of EVs, aiming to develop better water pollution monitoring tools. In combination with bioinformatics techniques, genetic tools including cloning sequencing analysis, DNA microarray, next-generation sequencing (NGS), and metagenomic sequencing technologies are implemented to make informed decisions about the global burden of waterborne EVs-associated diseases. The data presented in this review are helpful to recommend that: (1) Each viral pollution detection method has its own merits and demerits; therefore, it would be advantageous for viral pollution evaluation to be integrated as a complementary platform. (2) The total viral genome pool extracted from aquatic environmental samples is a real reflection of pollution status of the aquatic eco-systems; therefore, it is recommended to conduct regular sampling through the year to establish an updated monitoring system for EVs, and quantify viral peak concentrations, viral typing, and genotyping. (3) Despite that conventional detection methods are cheaper, it is highly recommended to implement molecular-based technologies to complement aquatic ecosystems biomonitoring due to numerous advantages including high-throughput capability. (4) Continuous implementation of the eco-genetic detection tools for monitoring the EVs in aquatic ecosystems is recommended.
Collapse
Affiliation(s)
- Gomaa Mostafa-Hedeab
- Pharmacology Department and Health Research Unit, Medical College, Jouf University, Skaka 11564, Saudi Arabia
| | - Abdou Kamal Allayeh
- Water Pollution Department, Virology Laboratory, National Research Centre, Dokki, Giza 12622, Egypt;
| | | | - Abozer Y. Eledrdery
- Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, Jouf University, Sakaka 11564, Saudi Arabia;
| | - Mobarak Abu Mraheil
- German Center for Infection Research (DZIF), Institute of Medical Microbiology, Justus-Liebig University, 35392 Giessen, Germany
| | - Ahmed Mostafa
- Center of Scientific Excellence for Influenza Viruses, National Research Centre, Giza 12622, Egypt
| |
Collapse
|
2
|
Hennechart-Collette C, Dehan O, Laurentie M, Fraisse A, Martin-Latil S, Perelle S. Method for detecting norovirus, hepatitis A and hepatitis E viruses in tap and bottled drinking water. Int J Food Microbiol 2022; 377:109757. [DOI: 10.1016/j.ijfoodmicro.2022.109757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 05/24/2022] [Accepted: 05/25/2022] [Indexed: 11/29/2022]
|
3
|
Hrdy J, Vasickova P. Virus detection methods for different kinds of food and water samples – The importance of molecular techniques. Food Control 2022. [DOI: 10.1016/j.foodcont.2021.108764] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
4
|
Vitek R, do Nascimento FH, Masini JC. Polymer monoliths for the concentration of viruses from environmental waters: A review. J Sep Sci 2021; 45:134-148. [PMID: 34128332 DOI: 10.1002/jssc.202100282] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 06/09/2021] [Accepted: 06/10/2021] [Indexed: 12/13/2022]
Abstract
Even at low concentrations in environmental waters, some viruses are highly infective, making them a threat to human health. They are the leading cause of waterborne enteric diseases. In agriculture, plant viruses in irrigation and runoff water threat the crops. The low concentrations pose a challenge to early contamination detection. Thus, concentrating the virus particles into a small volume may be mandatory to achieve reliable detection in molecular techniques. This paper reviews the organic monoliths developments and their applications to concentrate virus particles from waters (waste, surface, tap, sea, and irrigation waters). Free-radical polymerization and polyaddition reactions are the most common strategies to prepare the monoliths currently used for virus concentration. Here, the routes for preparing and functionalizing both methacrylate and epoxy-based monoliths will be shortly described, following a revision of their retention mechanisms and applications in the concentration of enteric and plant viruses in several kinds of waters.
Collapse
Affiliation(s)
- Renan Vitek
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, São Paulo, Brazil.,Instituto Federal de Educação Ciência e Tecnologia de Mato Grosso, Cuiabá, Brazil
| | - Fernando H do Nascimento
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, São Paulo, Brazil
| | - Jorge C Masini
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, São Paulo, Brazil
| |
Collapse
|
5
|
Nasser A, Sasi S, Nitzan Y. Coliphages as Indicators for the Microbial Quality of Treated Wastewater Effluents. FOOD AND ENVIRONMENTAL VIROLOGY 2021; 13:170-178. [PMID: 33428162 DOI: 10.1007/s12560-020-09459-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2020] [Accepted: 12/28/2020] [Indexed: 06/12/2023]
Abstract
Wastewater effluents are a reliable water source for non-potable water reuse including unrestricted crop irrigation in arid regions suffering from water scarcity. This study was performed to develop and optimize a procedure to concentrate coliphages from 100 L of treated effluent. Moreover, the reduction of coliphages by filtration and disinfection by either chlorine or UV was compared with that of fecal coliform (FC). The adsorption efficiency of MS2 and Qβ coliphages by the NanoCeram filter was similar and reached 99.8%. Elution efficiency of MS2 coliphage from the NanoCeram filters by a solution of 1% NaPP and 0.05 M glycine, pH 9.5, was 74 ± 9.5%. The highest reconcentration efficiency of MS2 and Qβ coliphages was obtained with polyethylene glycol (PEG) precipitation and reached 76 ± 28% and 90 ± 11%, respectively. In comparison, the reconcentration efficiency of organic flocculation was 0% and 1.3% for Qβ and MS2 coliphages, respectively. The overall recovery efficiency of MS2 coliphages from 100 L tertiary effluent was 57 ± 1.5%. Poor reduction was observed for coliphages compared to FC by filtration and chlorine disinfection although; the reduction of FC, as measured by cultivation, was satisfactory and within the guidelines for unrestricted irrigation. High correlation between the reduction of FC and coliphages was recorded for tertiary effluent disinfected by UV irradiation. Monitoring the microbial quality of tertiary effluent using qPCR for the enumeration of FC was found unsuitable, because DNA levels were unaffected by the treatment processes. The results of this study demonstrated that monitoring the microbial quality of tertiary effluent by FC may not reflect the health risks encountered by the application of these effluents and the addition of coliphages to the monitoring programs may allow for accurate assessment of the health risks introduced by the application of tertiary effluent.
Collapse
Affiliation(s)
- Abidelfatah Nasser
- Water Quality Research Laboratory, National Public Health Laboratory, Ministry of Health, Tel Aviv, Israel.
| | - Sivan Sasi
- Water Quality Research Laboratory, National Public Health Laboratory, Ministry of Health, Tel Aviv, Israel
- Faculty of Life Sciences, Bar-Ilan University, Ramat Gan, Israel
| | - Yeshayahu Nitzan
- Faculty of Life Sciences, Bar-Ilan University, Ramat Gan, Israel
| |
Collapse
|
6
|
Hennechart-Collette C, Dehan O, Fraisse A, Martin-Latil S, Perelle S. Evaluation of three different filters and two methods for recovering viruses from drinking water. J Virol Methods 2020; 284:113939. [PMID: 32673640 DOI: 10.1016/j.jviromet.2020.113939] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 07/10/2020] [Accepted: 07/12/2020] [Indexed: 01/13/2023]
Abstract
Among the enteric viruses implicated in waterborne outbreaks, human norovirus and hepatitis A virus (HAV) are a serious public health issue. Most foodborne viruses are difficult or currently unlikely to cultivate. Because of the lack of a cell culture method, real-time reverse transcriptase PCR is commonly used for the detection of norovirus in foodstuffs and environmental samples. Due to low infectious doses in humans and low virus concentration in water sample, filter adsorption methods were used for concentrating viruses from water. The ISO (Anonymous, ISO 15216-1, 2017) describes standardized molecular methods for detecting HAV and norovirus in bottled water. This method includes a two-step procedure: concentrating the virus using a microporous electropositive filter (47 mm diameter, 0.45 μm pore size) then molecular detection. The Zetapor filter, which had a charged membrane with a pore size of 0.45 μm, was commonly used in the past to concentrate viruses from water or from salad leaves following virus elution. But, unfortunately, the Zetapor filter is no longer marketed and it is therefore necessary to assess an alternative filter. The aim of this study was to compare the ability of two electropositive filters with a pore size of 0.45 μm or 0.22 μm and one uncharged filter (0.45 μm) to recover norovirus and HAV from two different types of drinking water (bottled water and tap water) with the adsorption-elution method proposed by ISO (Anonymous, ISO 15216-1, 2017) (method A) and with direct viral extraction using filters (method B). The mean extraction yields for norovirus and HAV calculated with RNA extracts ranged from 0.2 % - 4.81 % with method A and from 5.05 % - 53.58 % with method B, and did not differ significantly between the two types of drinking water tested. For method B, the mean extraction yields for HAV and norovirus were evaluated according to results from the three filters used. The recovery rate of HAV and norovirus ranged between 3.47 % and 62.41 % with the 0.45 μm electropositive filter and were higher than the other filters. The 0.45 μm electropositive filter could be used to concentrate viruses for routine viral monitoring of drinking water for researchers who want to adopt the method in their lab routine.
Collapse
Affiliation(s)
| | - Océane Dehan
- Université Paris-Est, ANSES, Laboratory for Food Safety, F-94700 Maisons-Alfort, France
| | - Audrey Fraisse
- Université Paris-Est, ANSES, Laboratory for Food Safety, F-94700 Maisons-Alfort, France
| | - Sandra Martin-Latil
- Université Paris-Est, ANSES, Laboratory for Food Safety, F-94700 Maisons-Alfort, France
| | - Sylvie Perelle
- Université Paris-Est, ANSES, Laboratory for Food Safety, F-94700 Maisons-Alfort, France.
| |
Collapse
|
7
|
Two Drinking Water Outbreaks Caused by Wastewater Intrusion Including Sapovirus in Finland. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16224376. [PMID: 31717479 PMCID: PMC6888097 DOI: 10.3390/ijerph16224376] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 11/06/2019] [Accepted: 11/06/2019] [Indexed: 12/27/2022]
Abstract
Drinking water outbreaks occur worldwide and may be caused by several factors, including raw water contamination, treatment deficiencies, and distribution network failure. This study describes two drinking water outbreaks in Finland in 2016 (outbreak I) and 2018 (outbreak II). Both outbreaks caused approximately 450 illness cases and were due to drinking water pipe breakage and subsequent wastewater intrusion into the distribution system. In both outbreaks, the sapovirus was found in patient samples as the main causative agent. In addition, adenoviruses and Dientamoeba fragilis (outbreak I), and noroviruses, astroviruses, enterotoxigenic and enterohemorragic Escherichia coli (ETEC and EHEC, respectively) and Plesiomonas shigelloides (outbreak II) were detected in patient samples. Water samples were analyzed for the selected pathogens largely based on the results of patient samples. In addition, traditional fecal indicator bacteria and host-specific microbial source tracking (MST) markers (GenBac3 and HF183) were analyzed from water. In drinking water, sapovirus and enteropathogenic E. coli (EPEC) were found in outbreak II. The MST markers proved useful in the detection of contamination and to ensure the success of contaminant removal from the water distribution system. As mitigation actions, boil water advisory, alternative drinking water sources and chlorination were organized to restrict the outbreaks and to clean the contaminated distribution network. This study highlights the emerging role of sapoviruses as a waterborne pathogen and warrants the need for testing of multiple viruses during outbreak investigation.
Collapse
|
8
|
Masciopinto C, De Giglio O, Scrascia M, Fortunato F, La Rosa G, Suffredini E, Pazzani C, Prato R, Montagna MT. Human health risk assessment for the occurrence of enteric viruses in drinking water from wells: Role of flood runoff injections. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 666:559-571. [PMID: 30807946 DOI: 10.1016/j.scitotenv.2019.02.107] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 02/06/2019] [Accepted: 02/07/2019] [Indexed: 05/18/2023]
Abstract
We demonstrated that floods can induce severe microbiological contamination of drinking water from wells and suggest strategies to better address water safety plans for groundwater drinking supplies. Since 2002, the Italian Water Research Institute (IRSA) has detected hepatitis A virus, adenovirus, rotavirus, norovirus, and enterovirus in water samples from wells in the Salento peninsula, southern Italy. Perturbations in the ionic strength in water flow can initiate strong virus detachments from terra rossa sediments in karst fractures. This study therefore explored the potential health impacts of prolonged runoff injections in Salento groundwater caused by severe flooding during October 2018. A mathematical model for virus fate and transport in fractures was applied to determine the impact of floodwater injection on groundwater quality by incorporating mechanisms that affect virus attachment/detachment and survival in flowing water at microscale. This model predicted target concentrations of enteric viruses that can occur unexpectedly in wells at considerable distances (5-8 km) from the runoff injection site (sinkhole). Subsequently, the health impact of viruses in drinking water supplied from contaminated wells was estimated during the summer on the Salento coast. Specific unpublished dose-response model coefficients were proposed to determine the infection probabilities for Echo-11 and Polio 1 enteroviruses through ingestion. The median (50%) risk of infection was estimated at 6.3 · 10-3 with an uncertainty of 23%. The predicted burden of diseases was 4.89 disability adjusted life years per year, i.e., twice the maximum tolerable disease burden. The results highlight the requirement for additional water disinfection treatments in Salento prior to the distribution of drinking water. Moreover, monthly controls of enteric virus occurrence in water from wells should be imposed by a new water framework directive in semiarid regions because of the vulnerability of karst carbonate aquifers to prolonged floodwater injections and enteric virus contamination.
Collapse
Affiliation(s)
- Costantino Masciopinto
- Consiglio Nazionale delle Ricerche, Istituto di Ricerca Sulle Acque (IRSA), Reparto di Chimica e Tecnologia delle Acque, Bari, Italy.
| | - Osvalda De Giglio
- Dipartimento di Scienze Biomediche e Oncologia Umana, Università degli Studi Aldo Moro, Bari, Italy
| | - Maria Scrascia
- Dipartimento di Biologia, Università degli Studi Aldo Moro, Bari, Italy
| | | | - Giuseppina La Rosa
- Dipartimento Ambiente e Salute, Istituto Superiore di Sanità, Roma, Italy
| | - Elisabetta Suffredini
- Dipartimento di Sicurezza Alimentare, Nutrizione e Sanità Pubblica Veterinaria, Istituto Superiore di Sanità, Roma, Italy
| | - Carlo Pazzani
- Dipartimento di Biologia, Università degli Studi Aldo Moro, Bari, Italy
| | - Rosa Prato
- Dipartimento di Scienze Mediche e Chirurgiche, Università di Foggia, Italy
| | - Maria Teresa Montagna
- Dipartimento di Scienze Biomediche e Oncologia Umana, Università degli Studi Aldo Moro, Bari, Italy
| |
Collapse
|
9
|
Sánchez G, Sánchez G. Food and Viral Contamination: Analytical Methods. Food Saf (Tokyo) 2016. [DOI: 10.1002/9781119160588.ch10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
10
|
Diduch M, Polkowska Ż, Namieśnik J. The role of heterotrophic plate count bacteria in bottled water quality assessment. Food Control 2016. [DOI: 10.1016/j.foodcont.2015.09.024] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Suzuki Y, Kobayashi T, Nishiyama M, Kono T. Concentration of MS2 phage in river water by a combined ferric colloid adsorption and foam separation-based method, with MS2 phage leaching from ferric colloid. J Biosci Bioeng 2016; 122:252-6. [PMID: 26868517 DOI: 10.1016/j.jbiosc.2016.01.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Revised: 01/05/2016] [Accepted: 01/06/2016] [Indexed: 01/17/2023]
Abstract
The concentration of MS2 phage as a model RNA virus in river water using a combined ferric colloid adsorption and foam separation-based method was examined. The MS2 phage concentrations were determined by the plaque-forming unit (PFU) method and reverse transcription quantitative PCR (RT-qPCR) analysis. When ferric colloid adsorption was performed prior to foam separation, MS2 phage was effectively removed from river water and concentrated in the generated foam within 7 min. The removal efficiency was >99% at the optimum iron and casein concentrations of 5 mg-Fe/L and 10 mg/L, respectively. Furthermore, based on the analysis of the collected ferric colloid dissolved using deferoxamine, the MS2 concentration in the colloid-dissolved solution was 190-fold higher than that found in raw water according to RT-qPCR analysis. This is a novel method for concentrating RNA viruses to facilitate their detection in river water using coagulation and foam separation combined with chelate dissolution of ferric flocs.
Collapse
Affiliation(s)
- Yoshihiro Suzuki
- Department of Civil and Environmental Engineering, Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibanadai-Nishi, Miyazaki 889-2192, Japan.
| | - Takumi Kobayashi
- Department of Civil and Environmental Engineering, Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibanadai-Nishi, Miyazaki 889-2192, Japan
| | - Masateru Nishiyama
- Department of Environment and Resource Science, Interdisciplinary Graduate School of Agriculture and Engineering, University of Miyazaki, 1-1 Gakuen Kibanadai-Nishi, Miyazaki 889-2192, Japan
| | - Tomoya Kono
- Department of Biochemistry and Applied Biosciences, Faculty of Agriculture, University of Miyazaki, 1-1 Gakuen Kibanadai-nishi, Miyazaki 889-2192, Japan
| |
Collapse
|
12
|
Hennechart-Collette C, Martin-Latil S, Guillier L, Perelle S. Determination of which virus to use as a process control when testing for the presence of hepatitis A virus and norovirus in food and water. Int J Food Microbiol 2015; 202:57-65. [PMID: 25771512 DOI: 10.1016/j.ijfoodmicro.2015.02.029] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Revised: 02/12/2015] [Accepted: 02/19/2015] [Indexed: 11/24/2022]
Abstract
Noroviruses (genogroup I (NoV GI) and genogroup II (NoV GII)) and the hepatitis A virus (HAV) are frequently involved in foodborne infections worldwide. They are mainly transmitted via the fecal-oral route, direct person-to-person contact or consumption of contaminated water and foods. In food virology, detection methods are currently based on identifying viral genomes using real-time reverse transcriptase PCR (RT-qPCR). One of the general requirements for detecting these viruses in food involves the use of a process control virus to monitor the quality of the entire viral extraction procedure as described in the ISO/TS 15216-1 and 15216-2 standards published in 2013. The selected process control virus should have similar morphological and physicochemical properties as the screened pathogenic virus and thus have the potential to provide comparable extraction efficiency. The aim of this study was to determine which virus should be used for process control, murine norovirus (MNV-1) or Mengovirus, when testing for the presence of HAV, NoV GI and NoV GII in bottled water, lettuce and semi-dried tomatoes. Food samples were spiked with HAV, NoV GI or NoV GII alone or in the presence of MNV-1 or Mengovirus. Recovery rates of each pathogenic virus were compared to those of both process control viruses using a multiple comparison procedure. Neither process control virus influenced the recovery of pathogenic virus regardless of the type of food matrix. MNV-1 was the most appropriate virus for validating the detection of HAV and NoV GII in all three food matrices as well as NoV GI in lettuce. Mengovirus proved to be the most appropriate control for NoV GI detection in bottled water and semi-dried tomatoes. The process control virus is essential for validating viral detection in food and the choice of virus depends on food type and the screened pathogenic virus.
Collapse
Affiliation(s)
- Catherine Hennechart-Collette
- Université Paris-Est, ANSES, Maisons-Alfort Laboratory for Food Safety, Enteric Viruses Unit, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort Cedex, France
| | - Sandra Martin-Latil
- Université Paris-Est, ANSES, Maisons-Alfort Laboratory for Food Safety, Enteric Viruses Unit, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort Cedex, France
| | - Laurent Guillier
- Université Paris-Est, ANSES, Maisons-Alfort Laboratory for Food Safety, Quantitative Risk Assessment Mission, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort Cedex, France
| | - Sylvie Perelle
- Université Paris-Est, ANSES, Maisons-Alfort Laboratory for Food Safety, Enteric Viruses Unit, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort Cedex, France.
| |
Collapse
|
13
|
Coudray-Meunier C, Fraisse A, Martin-Latil S, Guillier L, Delannoy S, Fach P, Perelle S. A comparative study of digital RT-PCR and RT-qPCR for quantification of Hepatitis A virus and Norovirus in lettuce and water samples. Int J Food Microbiol 2015; 201:17-26. [PMID: 25725459 DOI: 10.1016/j.ijfoodmicro.2015.02.006] [Citation(s) in RCA: 76] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2014] [Revised: 01/26/2015] [Accepted: 02/04/2015] [Indexed: 10/24/2022]
Abstract
Sensitive and quantitative detection of foodborne enteric viruses is classically achieved by quantitative RT-PCR (RT-qPCR). Recently, digital PCR (dPCR) was described as a novel approach to genome quantification without need for a standard curve. The performance of microfluidic digital RT-PCR (RT-dPCR) was compared to RT-qPCR for detecting the main viruses responsible for foodborne outbreaks (human Noroviruses (NoV) and Hepatitis A virus (HAV)) in spiked lettuce and bottled water. Two process controls (Mengovirus and Murine Norovirus) were used and external amplification controls (EAC) were added to examine inhibition of RT-qPCR and RT-dPCR. For detecting viral RNA and cDNA, the sensitivity of the RT-dPCR assays was either comparable to that of RT-qPCR (RNA of HAV, NoV GI, Mengovirus) or slightly (around 1 log10) decreased (NoV GII and MNV-1 RNA and of HAV, NoV GI, NoV GII cDNA). The number of genomic copies determined by dPCR was always from 0.4 to 1.7 log10 lower than the expected numbers of copies calculated by using the standard qPCR curve. Viral recoveries calculated by RT-dPCR were found to be significantly higher than by RT-qPCR for NoV GI, HAV and Mengovirus in water, and for NoV GII and HAV in lettuce samples. The RT-dPCR assay proved to be more tolerant to inhibitory substances present in lettuce samples. This absolute quantitation approach may be useful to standardize quantification of enteric viruses in bottled water and lettuce samples and may be extended to quantifying other human pathogens in food samples.
Collapse
Affiliation(s)
- Coralie Coudray-Meunier
- Université Paris-Est, ANSES, Food Safety Laboratory, Enteric Viruses Unit, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort cedex, France
| | - Audrey Fraisse
- Université Paris-Est, ANSES, Food Safety Laboratory, Enteric Viruses Unit, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort cedex, France
| | - Sandra Martin-Latil
- Université Paris-Est, ANSES, Food Safety Laboratory, Enteric Viruses Unit, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort cedex, France
| | - Laurent Guillier
- Université Paris-Est, ANSES, Food Safety Laboratory, Modelling of Bacterial Behaviour Unit, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort cedex, France
| | - Sabine Delannoy
- Université Paris-Est, ANSES, Food Safety Laboratory, IdentyPath, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort cedex, France
| | - Patrick Fach
- Université Paris-Est, ANSES, Food Safety Laboratory, IdentyPath, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort cedex, France
| | - Sylvie Perelle
- Université Paris-Est, ANSES, Food Safety Laboratory, Enteric Viruses Unit, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort cedex, France.
| |
Collapse
|
14
|
Terejánszky P, Makra I, Lukács A, Gyurcsányi RE. Nanopipet-Based Resistive Pulse Sensing to Follow Alterations in the Size and Concentration of Nanoparticles During Membrane Filtration. ELECTROANAL 2015. [DOI: 10.1002/elan.201400651] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
15
|
Rapid Methods for Quality Assurance of Foods: the Next Decade with Polymerase Chain Reaction (PCR)-Based Food Monitoring. FOOD ANAL METHOD 2014. [DOI: 10.1007/s12161-014-9915-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
16
|
Jin M, Guo X, Wang XW, Yang D, Shen ZQ, Qiu ZG, Chen ZL, Li JW. Development of a novel filter cartridge system with electropositive granule media to concentrate viruses from large volumes of natural surface water. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:6947-6956. [PMID: 24865258 DOI: 10.1021/es501415m] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Exposure to various infectious viruses in environmental drinking water can constitute a public health risk. However, it is difficult to detect viruses in water due to their low concentration. In this study, we have developed a novel filter cartridge system containing electropositive granule media (EGM). Viruses present in large volumes of environmental samples were adsorbed onto the EGM, and then recovered by elution and poly(ethylene glycol) (PEG) concentration. To evaluate the system's efficiency in viral recovery, poliovirus (PV-1), a surrogate for enteric viruses, was used to artificially contaminate river water samples which were then assayed by quantitative real-time PCR. To optimize the concentration procedure, the eluent type, water flow rate and properties (e.g., pH, bacterial, and viral loads), were evaluated. The highest virus recovery was obtained by pumping river water at a flow rate of 300 mL/min and then pushing 3 L of an eluent containing 3× broth [1.5% (w/v) NaCl, 3% (w/v) tryptone, 1.5% (w/v) beef powder] with 0.05 mol/L glycine through the filter. Using this procedure, the recovery efficiencies of PV-1 from 10 to 100 L of spiked river water were up to 99%. In addition, this method is virus load and pH dependent. Virus recovery was maximal at a load of between 10(3.5) and 10(5.5) TCID50 and a pH ranging from 5 to 7. The bacterial load in the water has no effect on virus recovery. Different types of viruses and surface water were tested to validate the system's applicability. Results revealed that the EGM filter cartridge was able to concentrate PV-1, human adenoviruses (HAdVs) and noroviruses (HuNoVs) with high efficiency from river, lake, and reservoir water. Furthermore, it showed more efficient recovery than glass wool and 1MDS filters. These data suggest that this system provides rapid and efficient virus recovery from a large volume of natural surface water and, as such, could be a useful tool in revealing the presence of viruses in surface water.
Collapse
Affiliation(s)
- Min Jin
- Department of Environment and Health, Institute of Health and Environmental Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety , Tianjin 300050, China
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Pérez-Méndez A, Chandler JC, Bisha B, Goodridge LD. Concentration of enteric viruses from tap water using an anion exchange resin-based method. J Virol Methods 2014; 206:95-8. [PMID: 24911889 DOI: 10.1016/j.jviromet.2014.05.025] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2014] [Revised: 05/27/2014] [Accepted: 05/29/2014] [Indexed: 11/29/2022]
Abstract
Detecting low concentrations of enteric viruses in water is needed for public health-related monitoring and control purposes. Thus, there is a need for sensitive, rapid and cost effective enteric viral concentration methods compatible with downstream molecular detection. Here, a virus concentration method based on adsorption of the virus to an anion exchange resin and direct isolation of nucleic acids is presented. Ten liter samples of tap water spiked with different concentrations (10-10,000 TCID50/10 L) of human adenovirus 40 (HAdV-40), hepatitis A virus (HAV) or rotavirus (RV) were concentrated and detected by real time PCR or real time RT-PCR. This method improved viral detection compared to direct testing of spiked water samples where the ΔCt was 12.1 for AdV-40 and 4.3 for HAV. Direct detection of RV in water was only possible for one of the three replicates tested (Ct of 37), but RV detection was improved using the resin method (all replicates tested positive with an average Ct of 30, n=3). The limit of detection of the method was 10 TCID50/10 L for HAdV-40 and HAV, and 100 TCID50/10 L of water for RV. These results compare favorably with detection limits reported for more expensive and laborious methods.
Collapse
Affiliation(s)
- A Pérez-Méndez
- Department of Animal Sciences, Colorado State University, Fort Collins, CO, USA.
| | - J C Chandler
- Department of Animal Science, University of Wyoming, Laramie, WY, USA.
| | - B Bisha
- Department of Animal Science, University of Wyoming, Laramie, WY, USA.
| | - L D Goodridge
- Department of Food Science and Agricultural Chemistry, McGill University, Ste. Anne de Bellevue, Quebec, Canada.
| |
Collapse
|
18
|
|
19
|
Butot S, Zuber S, Baert L. Sample preparation prior to molecular amplification: complexities and opportunities. Curr Opin Virol 2014; 4:66-70. [PMID: 24441295 DOI: 10.1016/j.coviro.2013.12.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2013] [Revised: 12/02/2013] [Accepted: 12/12/2013] [Indexed: 02/01/2023]
Abstract
Molecular amplification using Reverse Transcription quantitative Polymerase Chain Reaction (RT-qPCR) is currently considered as the gold standard to detect enteric human pathogenic viruses such as norovirus and hepatitis A virus in food and water. However, the molecular-based detection requires an adequate sampling strategy and a sample preparation specific for viruses. Sampling for enteric human viruses in water and food should not necessarily follow bacterial sampling plans. The development of a reference detection method including sample preparation as proposed in ISO/TS 15216 represents a milestone to facilitate the evaluation of the performance and eventually validation of future virus detection methods. The potential viral infectivity linked to a positive PCR result is a remaining issue and pretreatments allowing the differentiation of infectious viruses would be useful for future risk assessments.
Collapse
Affiliation(s)
- Sophie Butot
- Food Safety and Quality Competence Pillar, Nestlé Research Centre, Vers-chez-les-Blanc, Box 44, 1000 Lausanne 26, Switzerland.
| | - Sophie Zuber
- Food Safety and Quality Competence Pillar, Nestlé Research Centre, Vers-chez-les-Blanc, Box 44, 1000 Lausanne 26, Switzerland
| | - Leen Baert
- Food Safety and Quality Competence Pillar, Nestlé Research Centre, Vers-chez-les-Blanc, Box 44, 1000 Lausanne 26, Switzerland
| |
Collapse
|
20
|
Hennechart-Collette C, Martin-Latil S, Guillier L, Perelle S. Multiplex real-time RT-qPCR for the detection of Norovirus in bottled and tap water using murine norovirus as a process control. J Appl Microbiol 2013; 116:179-90. [DOI: 10.1111/jam.12345] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2013] [Revised: 09/06/2013] [Accepted: 09/09/2013] [Indexed: 11/27/2022]
Affiliation(s)
- C. Hennechart-Collette
- Food and Water Virology Unit; ANSES; Maisons-Alfort Laboratory for Food Safety; Maisons-Alfort Cedex France
| | - S. Martin-Latil
- Food and Water Virology Unit; ANSES; Maisons-Alfort Laboratory for Food Safety; Maisons-Alfort Cedex France
| | - L. Guillier
- Modelling of bacterial behaviour Unit; ANSES; Maisons-Alfort Laboratory for Food Safety; Maisons-Alfort Cedex France
| | - S. Perelle
- Food and Water Virology Unit; ANSES; Maisons-Alfort Laboratory for Food Safety; Maisons-Alfort Cedex France
| |
Collapse
|
21
|
Cashdollar JL, Wymer L. Methods for primary concentration of viruses from water samples: a review and meta-analysis of recent studies. J Appl Microbiol 2013; 115:1-11. [PMID: 23360578 DOI: 10.1111/jam.12143] [Citation(s) in RCA: 108] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2012] [Revised: 01/10/2013] [Accepted: 01/15/2013] [Indexed: 01/11/2023]
Abstract
Since the beginning of environmental virology in the mid-twentieth century, a key challenge to scientists in the environmental field has been how to collect, isolate and detect pathogenic viruses from water that is used for drinking and/or recreational purposes. Early studies investigated different types of membrane filters, with more sophisticated technologies being developed more recently. The purpose of this study was to look at the current state of the science of methods for the concentration of viruses from water. Several technologies were reviewed, and associated data were included in a meta-analysis which showed that electronegative filters, electropositive filters and ultrafilters are comparable in performance and that significant differences in recovery are due to virus type rather than filter type, water matrix or sample volume. This information is useful, as it will help to determine which method(s) should be used, particularly if there is a specific viral type being targeted for a particular study. In addition, it will be helpful when sampling different environmental water matrices and/or when budget allowance must be taken into consideration. Taken together, this will be useful in performing viral occurrence studies, which ultimately can help ensure safer water for both humans and the environment.
Collapse
Affiliation(s)
- J L Cashdollar
- U.S. EPA, Office of Research and Development, National Exposure Research Laboratory, Cincinnati, OH 45268, USA.
| | | |
Collapse
|
22
|
Recovery comparison of two virus concentration methods from wastewater using cell culture and real-time PCR. Curr Microbiol 2012; 65:432-7. [PMID: 22767318 DOI: 10.1007/s00284-012-0174-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2012] [Accepted: 06/04/2012] [Indexed: 10/28/2022]
Abstract
Enteric viruses are shed in the feces and may be present in environmental waters. Their detection in wastewater, even at low concentration, is a major challenge. In this study, recoveries of Echovirus 7 (EV7), virions and RNA in wastewater, using virus concentration methods were determined to evaluate the detection of infectious viruses and the possibility of recovering viral genomes. Two virus concentration methods, PEG precipitation method and two-phase separation method, were applied to recovery experiments of EV7-virions from wastewater, in parallel with recovery experiments of EV7 RNA. The titration of EV7 virions was carried out by cell culture using human rhabdomyosarcoma tumor tissue and the EV7 RNA quantification was performed by real-time PCR. The mean recovery yields of EV7 virions using the PEG precipitation method and the two-phase separation method were 78.5 ± 10.99 and 83.1 ± 0.28 %, respectively. Besides, EV7 RNA recoveries obtained using the PEG precipitation method were four times higher than those using the two-phase separation method. According to our results, the two methods enable to concentrate both infectious viruses and viral genomes. Moreover, considering the protocol time and cost together with the ratio of the EV7 virion recovery to the EV7 RNA recovery, the two-phase separation method (83.1/2.71 %, or 30.6) seems to be more appropriate for selective concentration of viral virions than the PEG precipitation method (78.5/10.33 %, or 7.6).
Collapse
|
23
|
Ikner LA, Gerba CP, Bright KR. Concentration and recovery of viruses from water: a comprehensive review. FOOD AND ENVIRONMENTAL VIROLOGY 2012; 4:41-67. [PMID: 23412811 DOI: 10.1007/s12560-012-9080-2] [Citation(s) in RCA: 133] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2012] [Accepted: 05/04/2012] [Indexed: 05/22/2023]
Abstract
Enteric viruses are a cause of waterborne disease worldwide, and low numbers in drinking water can present a significant risk of infection. Because the numbers are often quite low, large volumes (100-1,000 L) of water are usually processed. The VIRADEL method using microporous filters is most commonly used today for this purpose. Negatively charged filters require the addition of multivalent salts and acidification of the water sample to effect virus adsorption, which can make large-volume sampling difficult. Positively charged filters require no preconditioning of samples, and are able to concentrate viruses from water over a greater pH range than electronegative filters. The most widely used electropositive filter is the Virosorb 1MDS; however, the Environmental Protection Agency has added the positively charged NanoCeram filters to their proposed Method 1615. Ultrafilters concentrate viruses based on size exclusion rather than electrokinetics, but are impractical for field sampling or processing of turbid water. Elution (recovery) of viruses from filters following concentration is performed with organic (e.g., beef extract) or inorganic solutions (e.g., sodium polyphosphates). Eluates are then reconcentrated to decrease the sample volume to enhance detection methods (e.g., cell culture infectivity assays and molecular detection techniques). While the majority of available filters have demonstrated high virus retention efficiencies, the methods to elute and reconcentrate viruses have met with varying degrees of success due to the biological variability of viruses present in water.
Collapse
Affiliation(s)
- Luisa A Ikner
- Antimicrobial Test Laboratories, 1304W. Industrial Blvd, Round Rock, TX 78681, USA
| | | | | |
Collapse
|
24
|
Butot S, Putallaz T, Sánchez G. Improvement of Procedure for HAV Detection in Bottled Water. FOOD ANAL METHOD 2012. [DOI: 10.1007/s12161-012-9437-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
25
|
Martin-Latil S, Hennechart-Collette C, Guillier L, Perelle S. Duplex RT-qPCR for the detection of hepatitis E virus in water, using a process control. Int J Food Microbiol 2012; 157:167-73. [PMID: 22633799 DOI: 10.1016/j.ijfoodmicro.2012.05.001] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2011] [Revised: 04/02/2012] [Accepted: 05/02/2012] [Indexed: 01/27/2023]
Abstract
Human hepatitis E virus (HEV) causes acute hepatitis in humans, predominantly by contamination of food and water. HEV, in particular genotype III, is currently considered to be an emerging pathogen in industrialized countries. Because of the low infectious dose, an efficient and rapid virus concentration method is required to detect low amounts of HEV in food and water samples for routine control. Because of the absence of a reliable cell culture method for the main enteric viruses most involved in the outbreaks, reverse transcription quantitative real time PCR (RT-qPCR) is now widely used for the detection of RNA viruses in food and water samples. One of the general requirements for viral diagnosis concerns the use of a process control to monitor the efficiency of the concentration of viral particles, the extraction of nucleic acid and the presence of the potential inhibitors of the RT-qPCR reaction. The aim of this study was to provide a rapid and sensitive method for detecting HEV in water. The method is based on viral concentration by filtration on membrane filters and direct lysis of adsorbed viruses from filters before RNA extraction and RT-qPCR amplification. We developed a one-step duplex RT-qPCR for detecting HEV and the murine norovirus (MNV-1) was used as a process control. The data show that MNV-1 offers a very reliable and simple way of monitoring false-negative results and is a valuable tool in the routine diagnostic laboratory. The limit of detection (LOD) was in the range of 700 to 3500 HEV genome copies/0.5L bottled water and 3500 HEV genome copies/0.5L tap water.
Collapse
Affiliation(s)
- Sandra Martin-Latil
- ANSES, Maisons-Alfort Laboratory for Food Safety, Food and Water Virology Unit, Maisons-Alfort, France
| | | | | | | |
Collapse
|
26
|
Amdiouni H, Faouzi A, Fariat N, Hassar M, Soukri A, Nourlil J. Detection and molecular identification of human adenoviruses and enteroviruses in wastewater from Morocco. Lett Appl Microbiol 2012; 54:359-66. [PMID: 22324352 DOI: 10.1111/j.1472-765x.2012.03220.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
AIMS Reclaimed wastewater is a considerable water resource in Morocco. Its agricultural reuse requires an assessment of viral contamination. The aim of this study was to detect both infectious and noninfectious human adenoviruses (HAdV) and enteroviruses (EV) in raw wastewater and treat effluent from wastewater treatment plants (WWTPs) and domestic sewage in Morocco. METHODS AND RESULTS A total of 22 samples were analysed. A polyethylene glycol (PEG) precipitation method was used, followed by integrated cell culture-PCR (ICC-PCR) using two cell lines: human rhabdomyosarcoma tumour tissue and laryngeal carcinoma cells (RD and Hep2 cells). Furthermore, viral genome amplification was confirmed by sequencing. HAdV were detected in 10 (45·5%) of the 22 samples involving two species: HAdV-B and HAdV-D. EV was detected in 5 (23%) samples belonging to Coxsackievirus B5 and poliovirus vaccine strain (Sabin 2). CONCLUSIONS Human adenoviruses and EV were detected in the analysed samples from two WWTPs and HAdV in domestic sewage. SIGNIFICANCE AND IMPACT OF THE STUDY This work is the first study in Morocco using cell culture, PCR and sequencing of enteric viruses from wastewater. The presence of infectious HAdV and EV in treated effluent emphasizes the need of wastewater treatment surveillance.
Collapse
Affiliation(s)
- H Amdiouni
- Medical Virology and BSL3 Laboratory, Institut Pasteur du Maroc., Casablanca, Morocco
| | | | | | | | | | | |
Collapse
|
27
|
Stals A, Baert L, Van Coillie E, Uyttendaele M. Extraction of food-borne viruses from food samples: A review. Int J Food Microbiol 2012; 153:1-9. [DOI: 10.1016/j.ijfoodmicro.2011.10.014] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2011] [Revised: 10/14/2011] [Accepted: 10/24/2011] [Indexed: 10/15/2022]
|
28
|
Knutsson R. A tracing tool portfolio to detect Bacillus anthracis, Clostridium botulinum and Noroviruses: bioterrorism is a food safety and security issue. Int J Food Microbiol 2010; 145 Suppl 1:S121-2. [PMID: 21324542 DOI: 10.1016/j.ijfoodmicro.2010.12.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Rickard Knutsson
- Department of Bacteriology, National Veterinary Institute, SVA, Sweden.
| |
Collapse
|