1
|
Devlin C, Tomov ML, Chen H, Nama S, Ali S, Neelakantan S, Avazmohammadi R, Dasi LP, Bauser-Heaton HD, Serpooshan V. Patient-specific 3D in vitro modeling and fluid dynamic analysis of primary pulmonary vein stenosis. Front Cardiovasc Med 2024; 11:1432784. [PMID: 39026997 PMCID: PMC11254695 DOI: 10.3389/fcvm.2024.1432784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Accepted: 06/10/2024] [Indexed: 07/20/2024] Open
Abstract
Introduction Primary pulmonary vein stenosis (PVS) is a rare congenital heart disease that proves to be a clinical challenge due to the rapidly progressive disease course and high rates of treatment complications. PVS intervention is frequently faced with in-stent restenosis and persistent disease progression despite initial venous recanalization with balloon angioplasty or stenting. Alterations in wall shear stress (WSS) have been previously associated with neointimal hyperplasia and venous stenosis underlying PVS progression. Thus, the development of patient-specific three-dimensional (3D) in vitro models is needed to further investigate the biomechanical outcomes of endovascular and surgical interventions. Methods In this study, deidentified computed tomography images from three patients were segmented to generate perfusable phantom models of pulmonary veins before and after catheterization. These 3D reconstructions were 3D printed using a clear resin ink and used in a benchtop experimental setup. Computational fluid dynamic (CFD) analysis was performed on models in silico utilizing Doppler echocardiography data to represent the in vivo flow conditions at the inlets. Particle image velocimetry was conducted using the benchtop perfusion setup to analyze WSS and velocity profiles and the results were compared with those predicted by the CFD model. Results Our findings indicated areas of undesirable alterations in WSS before and after catheterization, in comparison with the published baseline levels in the healthy in vivo tissues that may lead to regional disease progression. Discussion The established patient-specific 3D in vitro models and the developed in vitro-in silico platform demonstrate great promise to refine interventional approaches and mitigate complications in treating patients with primary PVS.
Collapse
Affiliation(s)
- Christian Devlin
- Wallace H. Coulter Department of Biomedical Engineering, Emory University School of Medicine and Georgia Institute of Technology, Atlanta, GA, United States
| | - Martin L. Tomov
- Wallace H. Coulter Department of Biomedical Engineering, Emory University School of Medicine and Georgia Institute of Technology, Atlanta, GA, United States
| | - Huang Chen
- Wallace H. Coulter Department of Biomedical Engineering, Emory University School of Medicine and Georgia Institute of Technology, Atlanta, GA, United States
| | - Sindhu Nama
- Wallace H. Coulter Department of Biomedical Engineering, Emory University School of Medicine and Georgia Institute of Technology, Atlanta, GA, United States
| | - Siraj Ali
- Wallace H. Coulter Department of Biomedical Engineering, Emory University School of Medicine and Georgia Institute of Technology, Atlanta, GA, United States
| | - Sunder Neelakantan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States
| | - Reza Avazmohammadi
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States
- J. Mike Walker ‘66 Department of Mechanical Engineering, Texas A&M University, College Station, TX, United States
- School of Engineering Medicine, Texas A&M University, Houston, TX, United States
| | - Lakshmi Prasad Dasi
- Wallace H. Coulter Department of Biomedical Engineering, Emory University School of Medicine and Georgia Institute of Technology, Atlanta, GA, United States
| | - Holly D. Bauser-Heaton
- Wallace H. Coulter Department of Biomedical Engineering, Emory University School of Medicine and Georgia Institute of Technology, Atlanta, GA, United States
- Department of Pediatrics, Emory University School of Medicine, Atlanta, GA, United States
- Children’s Healthcare of Atlanta, Atlanta, GA, United States
- Sibley Heart Center, Children’s Healthcare of Atlanta, Atlanta, GA, United States
| | - Vahid Serpooshan
- Wallace H. Coulter Department of Biomedical Engineering, Emory University School of Medicine and Georgia Institute of Technology, Atlanta, GA, United States
- Department of Pediatrics, Emory University School of Medicine, Atlanta, GA, United States
- Children’s Healthcare of Atlanta, Atlanta, GA, United States
| |
Collapse
|
2
|
Akça Sümengen A, İsmailoğlu AV, İsmailoğlu P, Gümüş T, Çeliker A, Namlısesli D, Poyraz E, Özçevik Subaşı D, Zeren Erdem C, Çakır GN. The effect of 3D modeling on family quality of life, surgical success, and patient outcomes in congenital heart diseases: objectives and design of a randomized controlled trial. Turk J Pediatr 2024; 66:237-250. [PMID: 38814302 DOI: 10.24953/turkjpediatr.2024.4574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 04/30/2024] [Indexed: 05/31/2024]
Abstract
BACKGROUND Understanding the severity of the disease from the parents' perspective can lead to better patient outcomes, improving both the child's health-related quality of life and the family's quality of life. The implementation of 3-dimensional (3D) modeling technology in care is critical from a translational science perspective. AIM The purpose of this study is to determine the effect of 3D modeling on family quality of life, surgical success, and patient outcomes in congenital heart diseases. Additionally, we aim to identify challenges and potential solutions related to this innovative technology. METHODS The study is a two-group pretest-posttest randomized controlled trial protocol. The sample size is 15 in the experimental group and 15 in the control group. The experimental group's heart models will be made from their own computed tomography (CT) images and printed using a 3D printer. The experimental group will receive surgical simulation and preoperative parent education with their 3D heart model. The control group will receive the same parent education using the standard anatomical model. Both groups will complete the Sociodemographic Information Form, the Surgical Simulation Evaluation Form - Part I-II, and the Pediatric Quality of Life Inventory (PedsQL) Family Impacts Module. The primary outcome of the research is the average PedsQL Family Impacts Module score. Secondary outcome measurement includes surgical success and patient outcomes. Separate analyses will be conducted for each outcome and compared between the intervention and control groups. CONCLUSIONS Anomalies that can be clearly understood by parents according to the actual size and dimensions of the child's heart will affect the preoperative preparation of the surgical procedure and the recovery rate in the postoperative period.
Collapse
Affiliation(s)
- Aylin Akça Sümengen
- Department of Nursing, Faculty of Health Sciences, Yeditepe University, İstanbul, Türkiye
- Capstone College of Nursing, The University of Alabama, Alabama, United States of America
| | - Abdul Veli İsmailoğlu
- Department of Anatomy, School of Medicine, Acıbadem University, İstanbul, Türkiye
- Department of Anatomy, School of Medicine, Marmara University, İstanbul, Türkiye
| | - Pelin İsmailoğlu
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Fenerbahce University, İstanbul, Türkiye
- Department of Anatomy, School of Medicine, Recep Tayyip Erdoğan University, Rize, Türkiye
| | - Terman Gümüş
- Department of Radiology, School of Medicine, Koç University Research and Training Hospital, İstanbul, Türkiye
| | - Alpay Çeliker
- Pediatric Cardiology Department, American Hospital, İstanbul, Türkiye
| | - Deniz Namlısesli
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Yeditepe University, İstanbul, Türkiye
| | - Ezgi Poyraz
- Pediatric Cardiology Department, American Hospital, İstanbul, Türkiye
| | | | - Ceren Zeren Erdem
- Department of Nursing, Faculty of Health Sciences, Yeditepe University, İstanbul, Türkiye
| | - Gökçe Naz Çakır
- Department of Nursing, Faculty of Health Sciences, Yeditepe University, İstanbul, Türkiye
| |
Collapse
|
3
|
Zucker EJ. Cardiac Computed Tomography in Congenital Heart Disease. Radiol Clin North Am 2024; 62:435-452. [PMID: 38553179 DOI: 10.1016/j.rcl.2023.12.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/02/2024]
Abstract
Computed tomography (CT) has emerged as a leading imaging modality in the evaluation of congenital heart disease (CHD). With ever-faster acquisition speed, decreasing radiation exposure, impeccable anatomic detail, optional functional data, and numerous post-processing tools, CT offers broad utility in CHD diagnosis, preoperative planning, and postoperative assessment. In this article, the far-reaching role of CT in CHD is reviewed, focusing on technical imaging considerations and key clinical applications.
Collapse
Affiliation(s)
- Evan J Zucker
- Department of Radiology, Divisions of Pediatric and Cardiovascular Imaging, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA.
| |
Collapse
|
4
|
Zhang X, Yi K, Xu JG, Wang WX, Liu CF, He XL, Wang FN, Zhou GL, You T. Application of three-dimensional printing in cardiovascular diseases: a bibliometric analysis. Int J Surg 2024; 110:1068-1078. [PMID: 37924501 PMCID: PMC10871659 DOI: 10.1097/js9.0000000000000868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Accepted: 10/22/2023] [Indexed: 11/06/2023]
Abstract
AIM This paper aimed to explore the application of three-dimensional (3D) printing in cardiovascular diseases, to reach an insight in this field and prospect the future trend. METHODS The articles were selected from the Web of Science Core Collection database. Excel 2019, VOSviewer 1.6.16, and CiteSpace 6.1.R6 were used to analyze the information. RESULTS A total of 467 papers of 3D printing in cardiovascular diseases were identified, and the first included literature appeared in 2000. A total of 692 institutions from 52 countries participated in the relevant research, while the United States of America contributed to 160 articles and were in a leading position. The most productive institution was Curtin University , and Zhonghua Sun who has posted the most articles ( n =8) was also from there. The Frontiers in Cardiovascular Medicine published most papers ( n =25). The Journal of Thoracic and Cardiovascular Surgery coveted the most citations ( n =520). Related topics of frontiers will still focus on congenital heart disease, valvular heart disease, and left atrial appendage closure. CONCLUSIONS The authors summarized the publication information of the application of 3D printing in cardiovascular diseases related literature from 2000 to 2023, including country and institution of origin, authors, and publication journal. This study can reflect the current hotspots and novel directions for the application of 3D printing in cardiovascular diseases.
Collapse
Affiliation(s)
- Xin Zhang
- The First School of Clinical Medicine of Gansu University of Chinese Medicine
- Gansu International Scientific and Technological Cooperation Base of Diagnosis and Treatment of Congenital Heart Disease
| | - Kang Yi
- Gansu International Scientific and Technological Cooperation Base of Diagnosis and Treatment of Congenital Heart Disease
- Department of Cardiovascular Surgery, Gansu Provincial Hospital
| | - Jian-Guo Xu
- Evidence-Based Medicine Center, School of BasicMedical Sciences, Lanzhou University
| | - Wen-Xin Wang
- The First School of Clinical Medicine of Gansu University of Chinese Medicine
- Gansu International Scientific and Technological Cooperation Base of Diagnosis and Treatment of Congenital Heart Disease
| | - Cheng-Fei Liu
- Gansu International Scientific and Technological Cooperation Base of Diagnosis and Treatment of Congenital Heart Disease
- The First Clinical Medical College of Lanzhou University, Lanzhou, People's Republic of China
| | - Xiao-Long He
- The First School of Clinical Medicine of Gansu University of Chinese Medicine
- Gansu International Scientific and Technological Cooperation Base of Diagnosis and Treatment of Congenital Heart Disease
| | - Fan-Ning Wang
- The First School of Clinical Medicine of Gansu University of Chinese Medicine
- Gansu International Scientific and Technological Cooperation Base of Diagnosis and Treatment of Congenital Heart Disease
| | - Guo-Lei Zhou
- Gansu International Scientific and Technological Cooperation Base of Diagnosis and Treatment of Congenital Heart Disease
- Department of Cardiovascular Surgery, Gansu Provincial Hospital
| | - Tao You
- Gansu International Scientific and Technological Cooperation Base of Diagnosis and Treatment of Congenital Heart Disease
- Department of Cardiovascular Surgery, Gansu Provincial Hospital
| |
Collapse
|
5
|
Marella NT, Gil AM, Fan W, Aristizabal CA, Asrani P, Harrington JK, Channing A, Setton M, Shah AM, Levasseur S, Glickstein J, Farooqi KM. 3D-Printed Cardiac Models for Fetal Counseling: A Pilot Study and Novel Approach to Improve Communication. Pediatr Cardiol 2023; 44:1800-1807. [PMID: 37199756 PMCID: PMC10193324 DOI: 10.1007/s00246-023-03177-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Accepted: 05/05/2023] [Indexed: 05/19/2023]
Abstract
A fetal cardiology consultation involves using two-dimensional drawings to explain the cardiac anatomy which can result in inherent variation in how the congenital heart disease (CHD) is conveyed. In this pilot study, we incorporated three-dimensional printed (3DP) models into fetal counseling to demonstrate feasibility and evaluate the impact on parental knowledge, understanding, and anxiety. Parents with a prenatal diagnosis of a muscular ventricular septal defect (VSD) and/or coarctation of aorta were enrolled. Providers were randomized into a Model or Drawing Group and crossed after six months. Parents completed a survey after the consultation which evaluated knowledge of the CHD lesion, expectant surgical management, self-rated understanding, attitude towards the visualization tool, and anxiety. Twenty-nine patients enrolled over a 12 month period. Twelve consultations were done for coarctation of aorta, 13 for VSD, and four for coarctation with a VSD. Both Model and Drawing groups scored similarly in self-reported understanding and confidence, helpfulness of and improvement in communication with the visualization tool. The Model group had higher scores on questions related to the CHD anatomy and surgical intervention [5 [4-5] versus 4 [3.5-5]], p = 0.23 although this didn't reach statistical significance. For the majority (83%) of consultations, the cardiologist agreed that the 3D model improved communication. In this pilot study, we demonstrate the use of 3DP cardiac models during prenatal CHD counseling is feasible and produces results related to parental understanding and knowledge that are equal to and possibly better than the current standard of care.
Collapse
Affiliation(s)
- Nicole Toscana Marella
- Division of Pediatric Cardiology, NewYork-Presbyterian/Columbia University Irving Medical Center, 3959 Broadway, CHN-2, New York, NY, 10023, USA
- Division of Pediatric Cardiology, Children's National Hospital, Washington, DC, USA
| | - Adriana Montes Gil
- Division of Pediatric Cardiology, NewYork-Presbyterian/Columbia University Irving Medical Center, 3959 Broadway, CHN-2, New York, NY, 10023, USA
| | - Weijia Fan
- Columbia University Mailman School of Public Health, New York, NY, USA
| | | | - Priyanka Asrani
- Division of Pediatric Cardiology, NewYork-Presbyterian/Columbia University Irving Medical Center, 3959 Broadway, CHN-2, New York, NY, 10023, USA
| | - Jamie K Harrington
- Division of Pediatric Cardiology, University of Southern California, Los Angeles, CA, USA
| | - Alexandra Channing
- Division of Pediatric Cardiology, NewYork-Presbyterian/Columbia University Irving Medical Center, 3959 Broadway, CHN-2, New York, NY, 10023, USA
| | - Matan Setton
- Division of Pediatric Cardiology, NewYork-Presbyterian/Columbia University Irving Medical Center, 3959 Broadway, CHN-2, New York, NY, 10023, USA
| | - Amee M Shah
- Division of Pediatric Cardiology, NewYork-Presbyterian/Columbia University Irving Medical Center, 3959 Broadway, CHN-2, New York, NY, 10023, USA
| | - Stéphanie Levasseur
- Division of Pediatric Cardiology, NewYork-Presbyterian/Columbia University Irving Medical Center, 3959 Broadway, CHN-2, New York, NY, 10023, USA
| | - Julie Glickstein
- Division of Pediatric Cardiology, NewYork-Presbyterian/Columbia University Irving Medical Center, 3959 Broadway, CHN-2, New York, NY, 10023, USA
| | - Kanwal M Farooqi
- Division of Pediatric Cardiology, NewYork-Presbyterian/Columbia University Irving Medical Center, 3959 Broadway, CHN-2, New York, NY, 10023, USA.
| |
Collapse
|
6
|
Wang Y, Jin P, Meng X, Li L, Mao Y, Zheng M, Liu L, Liu Y, Yang J. Treatment of Severe Pulmonary Regurgitation in Enlarged Native Right Ventricular Outflow Tracts: Transcatheter Pulmonary Valve Replacement with Three-Dimensional Printing Guidance. Bioengineering (Basel) 2023; 10:1136. [PMID: 37892867 PMCID: PMC10604601 DOI: 10.3390/bioengineering10101136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Revised: 09/15/2023] [Accepted: 09/25/2023] [Indexed: 10/29/2023] Open
Abstract
BACKGROUND Severe pulmonary regurgitation (PR) often occurs following a transannular patch repair of tetralogy of Fallot, resulting in an enlarged native right ventricular outflow tract (nRVOT) with varying shapes. METHODS We conducted a single-center study with eight patients having severe PR and enlarged nRVOT (diameters ≥ 29 mm). Transcatheter pulmonary valve replacement (TPVR) was performed using the self-expanding PT-Valve. Preoperative evaluation included echocardiography, computed tomography, and magnetic resonance imaging. A 3D-printed model of the nRVOT was used for preoperative assessment. Follow-up data were collected in 1-year follow-up. RESULTS PT-Valve was successfully implanted in all patients, resulting in immediate improvement of severe PR. Pulmonary artery diastolic pressure increased significantly (p < 0.001). No deaths or coronary compression occurred during the procedure. Over a 1-year follow-up, no stent displacement or fracture occurred. Only two patients had trace paravalvular leaks. Magnetic resonance imaging revealed a reversal of right ventricular remodeling, with a significant reduction in right ventricular end-diastolic volume index (p < 0.001) and improved right ventricular ejection fraction (p < 0.001). All patients achieved primary endpoints. CONCLUSION 3D printing-guided PT-Valve implantation in enlarged nRVOT for severe PR is safe and effective, expanding TPVR indications and offering potential treatment for a broader patient population.
Collapse
Affiliation(s)
- Yiwei Wang
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi’an 710032, China; (Y.W.); (P.J.)
| | - Ping Jin
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi’an 710032, China; (Y.W.); (P.J.)
| | - Xin Meng
- Department of Ultrasound Medicine, Xijing Hospital, Air Force Medical University, Xi’an 710032, China
| | - Lanlan Li
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi’an 710032, China; (Y.W.); (P.J.)
| | - Yu Mao
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi’an 710032, China; (Y.W.); (P.J.)
| | - Minwen Zheng
- Department of Radiology, Xijing Hospital, Air Force Medical University, Xi’an 710032, China
| | - Liwen Liu
- Department of Ultrasound Medicine, Xijing Hospital, Air Force Medical University, Xi’an 710032, China
| | - Yang Liu
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi’an 710032, China; (Y.W.); (P.J.)
| | - Jian Yang
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi’an 710032, China; (Y.W.); (P.J.)
| |
Collapse
|
7
|
Sun Z, Zhao J, Leung E, Flandes-Iparraguirre M, Vernon M, Silberstein J, De-Juan-Pardo EM, Jansen S. Three-Dimensional Bioprinting in Cardiovascular Disease: Current Status and Future Directions. Biomolecules 2023; 13:1180. [PMID: 37627245 PMCID: PMC10452258 DOI: 10.3390/biom13081180] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 07/24/2023] [Accepted: 07/26/2023] [Indexed: 08/27/2023] Open
Abstract
Three-dimensional (3D) printing plays an important role in cardiovascular disease through the use of personalised models that replicate the normal anatomy and its pathology with high accuracy and reliability. While 3D printed heart and vascular models have been shown to improve medical education, preoperative planning and simulation of cardiac procedures, as well as to enhance communication with patients, 3D bioprinting represents a potential advancement of 3D printing technology by allowing the printing of cellular or biological components, functional tissues and organs that can be used in a variety of applications in cardiovascular disease. Recent advances in bioprinting technology have shown the ability to support vascularisation of large-scale constructs with enhanced biocompatibility and structural stability, thus creating opportunities to replace damaged tissues or organs. In this review, we provide an overview of the use of 3D bioprinting in cardiovascular disease with a focus on technologies and applications in cardiac tissues, vascular constructs and grafts, heart valves and myocardium. Limitations and future research directions are highlighted.
Collapse
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Radiation Science, Curtin Medical School, Curtin University, Perth, WA 6102, Australia;
- Curtin Health Innovation Research Institute (CHIRI), Curtin University, Perth, WA 6102, Australia
| | - Jack Zhao
- School of Medicine, Faculty of Health Sciences, The University of Western Australia, Perth, WA 6009, Australia; (J.Z.); (E.L.)
| | - Emily Leung
- School of Medicine, Faculty of Health Sciences, The University of Western Australia, Perth, WA 6009, Australia; (J.Z.); (E.L.)
| | - Maria Flandes-Iparraguirre
- Regenerative Medicine Program, Cima Universidad de Navarra, 31008 Pamplona, Spain;
- T3mPLATE, Harry Perkins Institute of Medical Research, QEII Medical Centre and UWA Centre for Medical Research, The University of Western Australia, Perth, WA 6009, Australia; (M.V.); (E.M.D.-J.-P.)
- School of Engineering, The University of Western Australia, Perth, WA 6009, Australia
| | - Michael Vernon
- T3mPLATE, Harry Perkins Institute of Medical Research, QEII Medical Centre and UWA Centre for Medical Research, The University of Western Australia, Perth, WA 6009, Australia; (M.V.); (E.M.D.-J.-P.)
- School of Engineering, The University of Western Australia, Perth, WA 6009, Australia
- Vascular Engineering Laboratory, Harry Perkins Institute of Medical Research, QEII Medical Centre and UWA Centre for Medical Research, The University of Western Australia, Perth, WA 6009, Australia
| | - Jenna Silberstein
- Discipline of Medical Radiation Science, Curtin Medical School, Curtin University, Perth, WA 6102, Australia;
| | - Elena M. De-Juan-Pardo
- T3mPLATE, Harry Perkins Institute of Medical Research, QEII Medical Centre and UWA Centre for Medical Research, The University of Western Australia, Perth, WA 6009, Australia; (M.V.); (E.M.D.-J.-P.)
- School of Engineering, The University of Western Australia, Perth, WA 6009, Australia
- Curtin Medical School, Curtin University, Perth, WA 6102, Australia;
| | - Shirley Jansen
- Curtin Medical School, Curtin University, Perth, WA 6102, Australia;
- Department of Vascular and Endovascular Surgery, Sir Charles Gairdner Hospital, Perth, WA 6009, Australia
- Heart and Vascular Research Institute, Harry Perkins Medical Research Institute, Perth, WA 6009, Australia
- School of Medicine, The University of Western Australia, Perth, WA 6009, Australia
| |
Collapse
|
8
|
Huang J, Wang H, Yang Y, Chen Q, Hu J, Shi H, Zhou Q. 3D printing of foetal vascular rings: feasibility and applicability. BMC Pregnancy Childbirth 2023; 23:355. [PMID: 37194003 DOI: 10.1186/s12884-023-05683-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Accepted: 05/06/2023] [Indexed: 05/18/2023] Open
Abstract
BACKGROUND Vascular rings (VRs) exhibit complex and diverse forms that are difficult to conceptualize using traditional two-dimensional (2D) schematic. Inexperienced medical students and parents who lack a medical technology background face significant challenges in understanding VRs. The purpose of this research is to develop three-dimensional (3D) printing models of VRs to provide new technical imaging support for medical education and parental consultation. METHODS This study included 42 fetuses diagnosed as VRs. Foetal echocardiography, modeling and 3D printing were performed, and the dimensional accuracy of models was analyzed. The value of 3D printing in the teaching of VRs was analyzed based on comparing the test results before and after the teaching intervention of 48 medical students and the satisfaction survey. A brief survey was conducted to 40 parents to assess the value of the 3D printed model in prenatal consultations. RESULTS Forty models of VRs were successfully obtained, which reproduced the anatomical shape of the VRs space with high dimensional accuracy. No differences in the prelecture test results were noted between the 3D printing group and the 2D image group. After the lecture, the knowledge of both groups improved, but the postlecture score and the change in the prelecture versus postlecture score were greater in the 3D printing group, and the subjective satisfaction survey feedback in the 3D printing group was also better (P < 0.05). Similar results were observed from the parental questionnaire, the vast majority of parents have an enthusiastic and positive attitude towards the use of 3D printed models and suggest using them in future prenatal consultations. CONCLUSIONS Three-dimensional printing technology providing a new tool for effectively displaying different types of foetal VRs. This tool helps physicians and families understand the complex structure of foetal great vessels, positively impacting medical instruction and prenatal counselling.
Collapse
Affiliation(s)
- Jia Huang
- Department of Obstetrics and Gynecology Ultrasound, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Hao Wang
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Yuanting Yang
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Qian Chen
- Department of Obstetrics and Gynecology Ultrasound, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Jiaqi Hu
- Department of Obstetrics and Gynecology Ultrasound, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Hua Shi
- Department of Obstetrics and Gynecology Ultrasound, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Qing Zhou
- Department of Ultrasound Imaging, Renmin Hospital of Wuhan University, Wuhan, 430060, China.
| |
Collapse
|
9
|
Alifu A, Wang H, Su Y, Chen R. Case report: Use of three-dimensional technology in criss-cross heart with double outlet right ventricle. Front Cardiovasc Med 2023; 10:1172104. [PMID: 37215548 PMCID: PMC10196189 DOI: 10.3389/fcvm.2023.1172104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 04/17/2023] [Indexed: 05/24/2023] Open
Abstract
Background In this case report, we utilized a three-dimensional printing model to replicate the complex anatomy of a criss-cross heart with double outlet right ventricle-an extremely rare congenital cardiac abnormality. This approach facilitated our understanding of the patient's unique condition and enabled us to plan the surgical procedure with greater precision. Case presentation Our department received a 13-year-old female patient who presented with a pronounced heart murmur and a decrease in exercise capacity. Subsequent two-dimensional imaging revealed the presence of a criss-cross heart with double outlet right ventricle-an intricate and uncommon cardiac malformation that poses challenges for accurate visualization through conventional two-dimensional modalities. To address this challenge, we constructed and printed a three-dimensional model using computed tomography data, which enabled us to visualize and understand the complex intracardiac structures and plan surgical interventions with greater precision. Using this approach, we successfully performed a right ventricular double outlet repair, and the patient made a full recovery following the procedure. Conclusion The criss-cross heart with double outlet right ventricle constitutes a complex and uncommon cardiac anomaly that poses considerable challenges in terms of diagnosis and surgical intervention. Employing three-dimensional modeling and printing represents a promising approach, given its potential to enhance the precision and comprehensiveness of the anatomical evaluation of the heart. As a result, this method holds significant promise in facilitating accurate diagnosis, meticulous surgical planning, and ultimately improving clinical outcomes for patients affected by this condition.
Collapse
|
10
|
Patient-Specific 3D-Printed Models in Pediatric Congenital Heart Disease. CHILDREN (BASEL, SWITZERLAND) 2023; 10:children10020319. [PMID: 36832448 PMCID: PMC9955978 DOI: 10.3390/children10020319] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 01/25/2023] [Accepted: 02/06/2023] [Indexed: 02/11/2023]
Abstract
Three-dimensional (3D) printing technology has become increasingly used in the medical field, with reports demonstrating its superior advantages in both educational and clinical value when compared with standard image visualizations or current diagnostic approaches. Patient-specific or personalized 3D printed models serve as a valuable tool in cardiovascular disease because of the difficulty associated with comprehending cardiovascular anatomy and pathology on 2D flat screens. Additionally, the added value of using 3D-printed models is especially apparent in congenital heart disease (CHD), due to its wide spectrum of anomalies and its complexity. This review provides an overview of 3D-printed models in pediatric CHD, with a focus on educational value for medical students or graduates, clinical applications such as pre-operative planning and simulation of congenital heart surgical procedures, and communication between physicians and patients/parents of patients and between colleagues in the diagnosis and treatment of CHD. Limitations and perspectives on future research directions for the application of 3D printing technology into pediatric cardiology practice are highlighted.
Collapse
|
11
|
Regeer MV, Ajmone Marsan N. Fusion imaging in congenital heart disease: just a pretty picture or a new tool to improve patient management? REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2023; 76:2-3. [PMID: 35760294 DOI: 10.1016/j.rec.2022.05.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 05/27/2022] [Indexed: 12/29/2022]
Affiliation(s)
| | - Nina Ajmone Marsan
- Heart Lung Center Leiden, Leiden University Medical Center, The Netherlands.
| |
Collapse
|
12
|
Lasso A, Herz C, Nam H, Cianciulli A, Pieper S, Drouin S, Pinter C, St-Onge S, Vigil C, Ching S, Sunderland K, Fichtinger G, Kikinis R, Jolley MA. SlicerHeart: An open-source computing platform for cardiac image analysis and modeling. Front Cardiovasc Med 2022; 9:886549. [PMID: 36148054 PMCID: PMC9485637 DOI: 10.3389/fcvm.2022.886549] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Accepted: 08/08/2022] [Indexed: 11/25/2022] Open
Abstract
Cardiovascular disease is a significant cause of morbidity and mortality in the developed world. 3D imaging of the heart's structure is critical to the understanding and treatment of cardiovascular disease. However, open-source tools for image analysis of cardiac images, particularly 3D echocardiographic (3DE) data, are limited. We describe the rationale, development, implementation, and application of SlicerHeart, a cardiac-focused toolkit for image analysis built upon 3D Slicer, an open-source image computing platform. We designed and implemented multiple Python scripted modules within 3D Slicer to import, register, and view 3DE data, including new code to volume render and crop 3DE. In addition, we developed dedicated workflows for the modeling and quantitative analysis of multi-modality image-derived heart models, including heart valves. Finally, we created and integrated new functionality to facilitate the planning of cardiac interventions and surgery. We demonstrate application of SlicerHeart to a diverse range of cardiovascular modeling and simulation including volume rendering of 3DE images, mitral valve modeling, transcatheter device modeling, and planning of complex surgical intervention such as cardiac baffle creation. SlicerHeart is an evolving open-source image processing platform based on 3D Slicer initiated to support the investigation and treatment of congenital heart disease. The technology in SlicerHeart provides a robust foundation for 3D image-based investigation in cardiovascular medicine.
Collapse
Affiliation(s)
- Andras Lasso
- Laboratory for Percutaneous Surgery, School of Computing, Queen's University, Kingston, ON, Canada
| | - Christian Herz
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, United States
| | - Hannah Nam
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, United States
| | - Alana Cianciulli
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, United States
| | | | - Simon Drouin
- Software and Information Technology Engineering, École de Technologie Supérieure, Montreal, QC, Canada
| | | | - Samuelle St-Onge
- Software and Information Technology Engineering, École de Technologie Supérieure, Montreal, QC, Canada
| | - Chad Vigil
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, United States
| | - Stephen Ching
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, United States
| | - Kyle Sunderland
- Laboratory for Percutaneous Surgery, School of Computing, Queen's University, Kingston, ON, Canada
| | - Gabor Fichtinger
- Laboratory for Percutaneous Surgery, School of Computing, Queen's University, Kingston, ON, Canada
| | - Ron Kikinis
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States
| | - Matthew A. Jolley
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, United States,Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA, United States,*Correspondence: Matthew A. Jolley
| |
Collapse
|
13
|
Spanaki A, Kabir S, Stephenson N, van Poppel MPM, Benetti V, Simpson J. 3D Approaches in Complex CHD: Where Are We? Funny Printing and Beautiful Images, or a Useful Tool? J Cardiovasc Dev Dis 2022; 9:269. [PMID: 36005432 PMCID: PMC9410138 DOI: 10.3390/jcdd9080269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 08/02/2022] [Accepted: 08/05/2022] [Indexed: 11/16/2022] Open
Abstract
Echocardiography, CT and MRI have a crucial role in the management of congenital heart disease (CHD) patients. All of these modalities can be presented in a 2D or a 3D rendered format. The aim of this paper is to review the key advantages and potential limitations, as well as the future challenges of a 3D approach in each imaging modality. The focus of this review is on anatomic rather than functional assessment. Conventional 2D echocardiography presents limitations when imaging complex lesions, whereas 3D imaging depicts the anatomy in all dimensions. CT and MRI can visualise extracardiac vasculature and guide complex biventricular repair. Three-dimensional printed models can be used in depicting complex intracardiac relationships and defining the surgical strategy in specific lesions. Extended reality imaging retained dynamic cardiac motion holds great potential for planning surgical and catheter procedures. Overall, the use of 3D imaging has resulted in a better understanding of anatomy, with a direct impact on the surgical and catheter approach, particularly in more complex cases.
Collapse
Affiliation(s)
- Adriani Spanaki
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London SE1 7EH, UK
| | - Saleha Kabir
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London SE1 7EH, UK
| | - Natasha Stephenson
- School of Biomedical Engineering & Imaging Sciences, King’s College London, King’s Health Partners, St Thomas’ Hospital, London SE1 7EH, UK
| | - Milou P. M. van Poppel
- School of Biomedical Engineering & Imaging Sciences, King’s College London, King’s Health Partners, St Thomas’ Hospital, London SE1 7EH, UK
| | - Valentina Benetti
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London SE1 7EH, UK
| | - John Simpson
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London SE1 7EH, UK
- School of Biomedical Engineering & Imaging Sciences, King’s College London, King’s Health Partners, St Thomas’ Hospital, London SE1 7EH, UK
| |
Collapse
|
14
|
Regeer MV, Ajmone Marsan N. Imágenes de fusión en cardiopatías congénitas, ¿solo una imagen bonita o una nueva herramienta para mejorar el tratamiento de los pacientes? Rev Esp Cardiol 2022. [DOI: 10.1016/j.recesp.2022.05.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
15
|
Navigation guidance for ventricular septal defect closure in heart phantoms. Int J Comput Assist Radiol Surg 2022; 17:1947-1956. [PMID: 35798998 DOI: 10.1007/s11548-022-02711-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Accepted: 06/24/2022] [Indexed: 11/05/2022]
Abstract
PURPOSE Transesophageal echocardiography (TEE) is the preferred imaging modality in a hybrid procedure used to close ventricular septal defects (VSDs). However, the limited field of view of TEE hinders the maneuvering of surgical instruments inside the beating heart. This study evaluates the accuracy of a method that aims to support navigation guidance in the hybrid procedure. METHODS A cardiologist maneuvered a needle to puncture the patient's heart and to access a VSD, guided by information displayed in a virtual environment. The information displayed included a model of the patient's heart and a virtual needle that reproduced the position and orientation of the real needle in real time. The physical and the virtual worlds were calibrated with a landmark registration and an iterative closest point algorithms, using an electromagnetic measurement system (EMS). For experiments, we developed a setup that included heart phantoms representing the patient's heart. RESULTS Experimental results from two pediatric cases studied suggested that the information provided for guidance was accurate enough when the landmark registration algorithm was fed with coordinates of seven points clearly identified on the surfaces of the physical and virtual hearts. Indeed, with a registration error of 2.28 mm RMS, it was possible to successfully access two VSDs (6.2 mm and 6.3 mm in diameter) in all the attempts with a needle (5 attempts) and a guidewire (7 attempts). CONCLUSION We found that information provided in a virtual environment facilitates guidance in the hybrid procedure for VSD closure. A clear identification of anatomical details in the heart surfaces is key to the accuracy of the procedure.
Collapse
|
16
|
Valverde I, Gomez G, Byrne N, Anwar S, Silva Cerpa MA, Martin Talavera M, Pushparajah K, Velasco Forte MN. Criss-cross heart three-dimensional printed models in medical education: A multicenter study on their value as a supporting tool to conventional imaging. ANATOMICAL SCIENCES EDUCATION 2022; 15:719-730. [PMID: 34008341 DOI: 10.1002/ase.2105] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 04/30/2021] [Accepted: 05/12/2021] [Indexed: 06/12/2023]
Abstract
The utility of three-dimensional (3D) printed models for medical education in complex congenital heart disease (CHD) is sparse and limited. The purpose of this study was to evaluate the utility of 3D printed models for medical education in criss-cross hearts covering a wide range of participants with different levels of knowledge and experience, from medical students, clinical fellows up to senior medical personnel. Study participants were enrolled from four dedicated imaging workshops developed between 2016 and 2019. The study design was a non-randomized cross-over study to evaluate 127 participants' level of understanding of the criss-cross heart anatomy. This was evaluated using the scores obtained following teaching with conventional images (echocardiography and magnetic resonance imaging) versus a 3D printed model learning approach. A significant improvement in anatomical knowledge of criss-cross heart anatomy was observed when comparing conventional imaging test scores to 3D printed model tests [76.9% (61.5%-87.8%) vs. 84.6% (76.9%-96.2%), P < 0.001]. The increase in the questionnaire marks was statistically significant across all academic groups (consultants in pediatric cardiology, fellows in pediatric cardiology, and medical students). Ninety-four percent (120) and 95.2% (121) of the participants agreed or strongly agreed, respectively, that 3D models helped them to better understand the medical images. Participants scored their overall satisfaction with the 3D printed models as 9.1 out of 10 points. In complex CHD such as criss-cross hearts, 3D printed replicas improve the understanding of cardiovascular anatomy. They enhanced the teaching experience especially when approaching medical students.
Collapse
Affiliation(s)
- Israel Valverde
- Pediatric Cardiology Unit, Hospital Virgen del Rocio, Seville, Spain
- Cardiovascular Pathology Unit and Fabrication Laboratory, Institute of Biomedicine of Seville, Seville, Spain
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Department of Congenital Heart Disease, Evelina London Children's Hospital, Guy's and St Thomas' National Health Service Foundation Trust, London, UK
| | - Gorka Gomez
- Cardiovascular Pathology Unit and Fabrication Laboratory, Institute of Biomedicine of Seville, Seville, Spain
| | - Nick Byrne
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Shafkat Anwar
- Division of Cardiology, Department of Pediatrics, University of California San Francisco School of Medicine, San Francisco, California, USA
| | | | | | - Kuberan Pushparajah
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Department of Congenital Heart Disease, Evelina London Children's Hospital, Guy's and St Thomas' National Health Service Foundation Trust, London, UK
| | - Maria Nieves Velasco Forte
- Cardiovascular Pathology Unit and Fabrication Laboratory, Institute of Biomedicine of Seville, Seville, Spain
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Department of Pediatric Cardiology, University of Bristol, Bristol Royal Hospital for Children, Bristol, UK
| |
Collapse
|
17
|
Brantnell A, Sandgren S, Wolff A, Temiz S. Barriers and Facilitators to the Implementation of Additive Manufacturing in Cardiology: A Qualitative Study. ANNALS OF 3D PRINTED MEDICINE 2022. [DOI: 10.1016/j.stlm.2022.100067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
18
|
Three-Dimensional (3D) Printing in Cancer Therapy and Diagnostics: Current Status and Future Perspectives. Pharmaceuticals (Basel) 2022; 15:ph15060678. [PMID: 35745597 PMCID: PMC9229198 DOI: 10.3390/ph15060678] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Revised: 05/23/2022] [Accepted: 05/25/2022] [Indexed: 12/10/2022] Open
Abstract
Three-dimensional (3D) printing is a technique where the products are printed layer-by-layer via a series of cross-sectional slices with the exact deposition of different cell types and biomaterials based on computer-aided design software. Three-dimensional printing can be divided into several approaches, such as extrusion-based printing, laser-induced forward transfer-based printing systems, and so on. Bio-ink is a crucial tool necessary for the fabrication of the 3D construct of living tissue in order to mimic the native tissue/cells using 3D printing technology. The formation of 3D software helps in the development of novel drug delivery systems with drug screening potential, as well as 3D constructs of tumor models. Additionally, several complex structures of inner tissues like stroma and channels of different sizes are printed through 3D printing techniques. Three-dimensional printing technology could also be used to develop therapy training simulators for educational purposes so that learners can practice complex surgical procedures. The fabrication of implantable medical devices using 3D printing technology with less risk of infections is receiving increased attention recently. A Cancer-on-a-chip is a microfluidic device that recreates tumor physiology and allows for a continuous supply of nutrients or therapeutic compounds. In this review, based on the recent literature, we have discussed various printing methods for 3D printing and types of bio-inks, and provided information on how 3D printing plays a crucial role in cancer management.
Collapse
|
19
|
Brunner BS, Thierij A, Jakob A, Tengler A, Grab M, Thierfelder N, Leuner CJ, Haas NA, Hopfner C. 3D-printed heart models for hands-on training in pediatric cardiology - the future of modern learning and teaching? GMS JOURNAL FOR MEDICAL EDUCATION 2022; 39:Doc23. [PMID: 35692357 PMCID: PMC9174069 DOI: 10.3205/zma001544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Revised: 10/05/2021] [Accepted: 01/24/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND This project aims to develop a new concept in training pediatric cardiologists to meet the requirements of interventional cardiac catheterizations today in terms of complexity and importance. This newly developed hands-on training program is supposed to enable the acquisition of certain skills which are necessary when investigating and treating patients in a catheter laboratory. METHODS Based on anonymous CT-scans of pediatric patients' digital 3D heart models with or without cardiac defects were developed and printed three-dimensionally in a flexible material visible under X-ray. Hands-on training courses were offered using models of a healthy heart and the most common congenital heart defects (CHD). An evaluation was performed by quantifying fluoroscopy times (FL-time) and a questionnaire. RESULTS The acceptance of theoretical and practical contents within the hands-on training was very positive. It was demonstrated that it is possible to master various steps of a diagnostic procedure and an intervention as well as to practice and repeat them independently which significantly reduced FL-time. The participants stated that the hands-on training led to more confidence in interventions on real patients. CONCLUSION With the development of a training module using 3D-printed heart models, basic and advanced training in the field of diagnostic cardiac examinations as well as interventional therapies of CHD is possible. The learning effect for both, practical skills and theoretical understanding, was significant which underlines the importance of integrating such hands-on trainings on 3D heart models in education and practical training.
Collapse
Affiliation(s)
- Barbara S. Brunner
- LMU Klinikum, Department of Pediatric Cardiology and Pediatric Intensive Care, Munich, Germany
| | - Alisa Thierij
- LMU Klinikum, Department of Pediatric Cardiology and Pediatric Intensive Care, Munich, Germany
| | - Andre Jakob
- LMU Klinikum, Department of Pediatric Cardiology and Pediatric Intensive Care, Munich, Germany
| | - Anja Tengler
- LMU Klinikum, Department of Pediatric Cardiology and Pediatric Intensive Care, Munich, Germany
| | - Maximilian Grab
- LMU Klinikum, Clinic and Polyclinic for Cardiac Surgery, Munich, Germany
| | | | | | - Nikolaus A. Haas
- LMU Klinikum, Department of Pediatric Cardiology and Pediatric Intensive Care, Munich, Germany
| | - Carina Hopfner
- LMU Klinikum, Department of Pediatric Cardiology and Pediatric Intensive Care, Munich, Germany
| |
Collapse
|
20
|
Cornejo J, Cornejo-Aguilar JA, Vargas M, Helguero CG, Milanezi de Andrade R, Torres-Montoya S, Asensio-Salazar J, Rivero Calle A, Martínez Santos J, Damon A, Quiñones-Hinojosa A, Quintero-Consuegra MD, Umaña JP, Gallo-Bernal S, Briceño M, Tripodi P, Sebastian R, Perales-Villarroel P, De la Cruz-Ku G, Mckenzie T, Arruarana VS, Ji J, Zuluaga L, Haehn DA, Paoli A, Villa JC, Martinez R, Gonzalez C, Grossmann RJ, Escalona G, Cinelli I, Russomano T. Anatomical Engineering and 3D Printing for Surgery and Medical Devices: International Review and Future Exponential Innovations. BIOMED RESEARCH INTERNATIONAL 2022; 2022:6797745. [PMID: 35372574 PMCID: PMC8970887 DOI: 10.1155/2022/6797745] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 02/16/2022] [Accepted: 02/24/2022] [Indexed: 12/26/2022]
Abstract
Three-dimensional printing (3DP) has recently gained importance in the medical industry, especially in surgical specialties. It uses different techniques and materials based on patients' needs, which allows bioprofessionals to design and develop unique pieces using medical imaging provided by computed tomography (CT) and magnetic resonance imaging (MRI). Therefore, the Department of Biology and Medicine and the Department of Physics and Engineering, at the Bioastronautics and Space Mechatronics Research Group, have managed and supervised an international cooperation study, in order to present a general review of the innovative surgical applications, focused on anatomical systems, such as the nervous and craniofacial system, cardiovascular system, digestive system, genitourinary system, and musculoskeletal system. Finally, the integration with augmented, mixed, virtual reality is analyzed to show the advantages of personalized treatments, taking into account the improvements for preoperative, intraoperative planning, and medical training. Also, this article explores the creation of devices and tools for space surgery to get better outcomes under changing gravity conditions.
Collapse
Affiliation(s)
- José Cornejo
- Facultad de Ingeniería, Universidad San Ignacio de Loyola, La Molina, Lima 15024, Peru
- Department of Medicine and Biology & Department of Physics and Engineering, Bioastronautics and Space Mechatronics Research Group, Lima 15024, Peru
| | | | | | | | - Rafhael Milanezi de Andrade
- Robotics and Biomechanics Laboratory, Department of Mechanical Engineering, Universidade Federal do Espírito Santo, Brazil
| | | | | | - Alvaro Rivero Calle
- Department of Oral and Maxillofacial Surgery, Hospital 12 de Octubre, Madrid, Spain
| | - Jaime Martínez Santos
- Department of Neurosurgery, Medical University of South Carolina, Charleston, SC, USA
| | - Aaron Damon
- Department of Neurosurgery, Mayo Clinic, FL, USA
| | | | | | - Juan Pablo Umaña
- Cardiovascular Surgery, Instituto de Cardiología-Fundación Cardioinfantil, Universidad del Rosario, Bogotá DC, Colombia
| | | | - Manolo Briceño
- Villamedic Group, Lima, Peru
- Clínica Internacional, Lima, Peru
| | | | - Raul Sebastian
- Department of Surgery, Northwest Hospital, Randallstown, MD, USA
| | | | - Gabriel De la Cruz-Ku
- Universidad Científica del Sur, Lima, Peru
- Department of Surgery, Mayo Clinic, Rochester, MN, USA
| | | | | | - Jiakai Ji
- Obstetrics and Gynecology, Lincoln Medical and Mental Health Center, Bronx, NY, USA
| | - Laura Zuluaga
- Department of Urology, Fundación Santa Fe de Bogotá, Colombia
| | | | - Albit Paoli
- Howard University Hospital, Washington, DC, USA
| | | | | | - Cristians Gonzalez
- Nouvel Hôpital Civil, Hôpitaux Universitaires de Strasbourg, Strasbourg, France
- Institut of Image-Guided Surgery (IHU-Strasbourg), Strasbourg, France
| | | | - Gabriel Escalona
- Experimental Surgery and Simulation Center, Department of Digestive Surgery, Catholic University of Chile, Santiago, Chile
| | - Ilaria Cinelli
- Aerospace Human Factors Association, Aerospace Medical Association, VA, USA
| | | |
Collapse
|
21
|
Stereogram of the Living Heart, Lung, and Adjacent Structures. Tomography 2022; 8:824-841. [PMID: 35314645 PMCID: PMC8938811 DOI: 10.3390/tomography8020068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 02/26/2022] [Accepted: 03/15/2022] [Indexed: 11/16/2022] Open
Abstract
Innovations in invasive cardiovascular diagnostics and therapeutics, not only limited to transcatheter approaches but also involving surgical approaches, are based on a precise appreciation of the three-dimensional living heart anatomy. Rapid advancements in three-dimensional cardiovascular imaging technologies in the 21st century have supported such innovations through the periprocedural assessment of the clinical anatomy of the living heart. However, even if high-resolution volume-rendered images are reconstructed, they cannot provide appropriate depth perception when displayed and shared on a two-dimensional display, which is widely used in clinical settings. Currently, images reconstructed from clinical datasets can visualize fine details of the cardiovascular anatomy. Therefore, this is an optimal time for cardiologists and cardiac surgeons to revisit the classic technology, stereopsis, and obtain bonus information from carefully reconstructed clinical images. Using anaglyphs or cross/uncross-fusion of paired images, striking depth perception can be readily obtained without the need for expensive equipment. This conventional technique, when applied to high-resolution volume-rendered images, may help in obtaining appropriate diagnostics, choosing optimal therapeutics, securing procedural success, and preventing complications. Furthermore, it can be used for anatomical education. In this review, we demonstrate multiple stereoscopic images reconstructed from cardiac computed tomographic datasets and discuss their clinical and educational implications.
Collapse
|
22
|
van de Woestijne PC, Bakhuis W, Sadeghi AH, Peek JJ, Taverne YJ, Bogers AJ. 3D Virtual Reality Imaging of Major Aortopulmonary Collateral Arteries: A Novel Diagnostic Modality. World J Pediatr Congenit Heart Surg 2021; 12:765-772. [PMID: 34812684 PMCID: PMC8637380 DOI: 10.1177/21501351211045064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 07/19/2021] [Accepted: 08/19/2021] [Indexed: 11/25/2022]
Abstract
BACKGROUND Major aortopulmonary collateral arteries (MAPCAs), as seen in patients with pulmonary atresia, are arteries that supply blood from the aorta to the lungs and often require surgical intervention. To achieve complete repair in the least number of interventions, optimal imaging of the pulmonary arterial anatomy and MAPCAs is critical. 3D virtual reality (3D-VR) is a promising and upcoming new technology that could potentially ameliorate current imaging shortcomings. METHODS A retrospective, proof-of-concept study was performed of all operated patients with pulmonary atresia and MAPCAs at our center between 2010 and 2020 with a preoperative computed tomography (CT) scan. CT images were reviewed by two congenital cardiac surgeons in 3D-VR to determine additional value of VR for MAPCA imaging compared to conventional CT and for preoperative planning of MAPCA repair. RESULTS 3D-VR visualizations were reconstructed from CT scans of seven newborns where the enhanced topographic anatomy resulted in improved visualization of MAPCA. In addition, surgical planning was improved since new observations or different preoperative plans were apparent in 4 out of 7 cases. After the initial setup, VR software and hardware was reported to be easy and intuitive to use. CONCLUSIONS This study showed technical feasibility of 3D-VR reconstruction of children with immersive visualization of topographic anatomy in an easy-to-use format leading to an improved surgical planning of MAPCA surgery. Future prospective studies are required to investigate the clinical benefits in larger populations.
Collapse
Affiliation(s)
| | - Wouter Bakhuis
- Thoraxcenter, Erasmus University Medical
Center, Rotterdam, the Netherlands
| | - Amir H. Sadeghi
- Thoraxcenter, Erasmus University Medical
Center, Rotterdam, the Netherlands
| | - Jette J. Peek
- Thoraxcenter, Erasmus University Medical
Center, Rotterdam, the Netherlands
| | | | - Ad J.J.C. Bogers
- Thoraxcenter, Erasmus University Medical
Center, Rotterdam, the Netherlands
| |
Collapse
|
23
|
Three-dimensional printing to plan intracardiac operations. JTCVS Tech 2021; 9:101-108. [PMID: 34647075 PMCID: PMC8500990 DOI: 10.1016/j.xjtc.2021.02.050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Accepted: 02/11/2021] [Indexed: 11/24/2022] Open
|
24
|
Awori J, Friedman SD, Chan T, Howard C, Seslar S, Soriano BD, Buddhe S. 3D models improve understanding of congenital heart disease. 3D Print Med 2021; 7:26. [PMID: 34471999 PMCID: PMC8411549 DOI: 10.1186/s41205-021-00115-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 06/27/2021] [Indexed: 11/20/2022] Open
Abstract
Introduction Understanding congenital heart disease (CHD) is vital for medical personnel and parents of affected children. While traditional 2D schematics serve as the typical approach used, several studies have shown these models to be limiting in understanding complex structures. Recent world-emphasis has shifted to 3D printed models as a complement to 2D imaging to bridge knowledge and create new opportunities for experiential learning. We sought to systematically compare 3D digital and physical models for medical personnel and parent education compared to traditional methods. Methods 3D printed and digital models were made out of MRI and CT data for 20 common CHD. Fellows and nurse practitioners used these models to explore intra-cardiac pathologies following traditional teaching. The models were also used for parent education in outpatient settings after traditional education. The participants were then asked to fill out a Likert scale questionnaire to assess their understanding and satisfaction with different teaching techniques. These ratings were compared using paired t-tests and Pearson’s correlation. Results Twenty-five medical personnel (18 fellows; 2 nurses; 4 nurse practitioners and one attending) and twenty parents participated in the study. The diagnosis varied from simple mitral valve pathology to complex single ventricle palliation. Parent and medical personnel perceived understanding with digital models was significantly higher than traditional (p = 0.01). Subjects also felt that physical models were overall more useful than digital ones (p = 0.001). Physicians using models for parent education also perceived the models to be useful, not significantly impacting their clinical workflow. Conclusions 3D models, both digital and printed, enhance medical personnel and parental perceived understanding of CHD. Supplementary Information The online version contains supplementary material available at 10.1186/s41205-021-00115-7.
Collapse
Affiliation(s)
- Jonathan Awori
- Division of Pediatric Cardiology and Radiology, Seattle Children's Hospital, Seattle, WA, USA.
| | - Seth D Friedman
- Division of Pediatric Cardiology and Radiology, Seattle Children's Hospital, Seattle, WA, USA
| | - Titus Chan
- Division of Pediatric Cardiology and Radiology, Seattle Children's Hospital, Seattle, WA, USA
| | - Christopher Howard
- Division of Pediatric Cardiology and Radiology, Seattle Children's Hospital, Seattle, WA, USA
| | - Steve Seslar
- Division of Pediatric Cardiology and Radiology, Seattle Children's Hospital, Seattle, WA, USA
| | - Brian D Soriano
- Division of Pediatric Cardiology and Radiology, Seattle Children's Hospital, Seattle, WA, USA
| | - Sujatha Buddhe
- Division of Pediatric Cardiology and Radiology, Seattle Children's Hospital, Seattle, WA, USA
| |
Collapse
|
25
|
Lau I, Gupta A, Sun Z. Clinical Value of Virtual Reality versus 3D Printing in Congenital Heart Disease. Biomolecules 2021; 11:884. [PMID: 34198642 PMCID: PMC8232263 DOI: 10.3390/biom11060884] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 06/10/2021] [Accepted: 06/12/2021] [Indexed: 11/22/2022] Open
Abstract
Both three-dimensional (3D) printing and virtual reality (VR) are reported as being superior to the current visualization techniques in conveying more comprehensive visualization of congenital heart disease (CHD). However, little is known in terms of their clinical value in diagnostic assessment, medical education, and preoperative planning of CHD. This cross-sectional study aims to address these by involving 35 medical practitioners to subjectively evaluate VR visualization of four selected CHD cases in comparison with the corresponding 3D printed heart models (3DPHM). Six questionnaires were excluded due to incomplete sections, hence a total of 29 records were included for the analysis. The results showed both VR and 3D printed heart models were comparable in terms of the degree of realism. VR was perceived as more useful in medical education and preoperative planning compared to 3D printed heart models, although there was no significant difference in the ratings (p = 0.54 and 0.35, respectively). Twenty-one participants (72%) indicated both the VR and 3DPHM provided additional benefits compared to the conventional medical imaging visualizations. This study concludes the similar clinical value of both VR and 3DPHM in CHD, although further research is needed to involve more cardiac specialists for their views on the usefulness of these tools.
Collapse
Affiliation(s)
- Ivan Lau
- Discipline of Medical Radiation Science, Curtin Medical School, Curtin University, Perth, WA 6102, Australia;
| | - Ashu Gupta
- Department of Medical Imaging, Fiona Stanley Hospital, Perth, WA 6150, Australia;
| | - Zhonghua Sun
- Discipline of Medical Radiation Science, Curtin Medical School, Curtin University, Perth, WA 6102, Australia;
- Curtin Health Innovation Research Institute (CHIRI), Faculty of Health Sciences, Curtin University, Perth, WA 6102, Australia
| |
Collapse
|
26
|
Bruckheimer E, Goreczny S. Advanced imaging techniques to assist transcatheter congenital heart defects therapies. PROGRESS IN PEDIATRIC CARDIOLOGY 2021. [DOI: 10.1016/j.ppedcard.2021.101373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
27
|
Sedlakova V, McTiernan C, Cortes D, Suuronen EJ, Alarcon EI. 3D Bioprinted Cardiac Tissues and Devices for Tissue Maturation. Cells Tissues Organs 2021; 211:406-419. [PMID: 33677445 DOI: 10.1159/000512792] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Accepted: 10/27/2020] [Indexed: 11/19/2022] Open
Abstract
Cardiovascular diseases are the leading cause of mortality worldwide. Given the limited endogenous regenerative capabilities of cardiac tissue, patient-specific anatomy, challenges in treatment options, and shortage of donor tissues for transplantation, there is an urgent need for novel approaches in cardiac tissue repair. 3D bioprinting is a technology based on additive manufacturing which allows for the design of precisely controlled and spatially organized structures, which could possibly lead to solutions in cardiac tissue repair. In this review, we describe the basic morphological and physiological specifics of the heart and cardiac tissues and introduce the readers to the fundamental principles underlying 3D printing technology and some of the materials/approaches which have been used to date for cardiac repair. By summarizing recent progress in 3D printing of cardiac tissue and valves with respect to the key features of cardiovascular tissue (such as contractility, conductivity, and vascularization), we highlight how 3D printing can facilitate surgical planning and provide custom-fit implants and properties that match those from the native heart. Finally, we also discuss the suitability of this technology in the design and fabrication of custom-made devices intended for the maturation of the cardiac tissue, a process that has been shown to increase the viability of implants. Altogether this review shows that 3D printing and bioprinting are versatile and highly modulative technologies with wide applications in cardiac regeneration and beyond.
Collapse
Affiliation(s)
- Veronika Sedlakova
- BEaTS Research, Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, Canada.,Department of Histology and Embryology, Faculty of Medicine, Masaryk University, Brno, Czechia
| | - Christopher McTiernan
- BEaTS Research, Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| | - David Cortes
- BEaTS Research, Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| | - Erik J Suuronen
- BEaTS Research, Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| | - Emilio I Alarcon
- BEaTS Research, Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, Canada, .,Department of Biochemistry, Microbiology, and Immunology, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada,
| |
Collapse
|
28
|
Yoo SJ, Hussein N, Peel B, Coles J, van Arsdell GS, Honjo O, Haller C, Lam CZ, Seed M, Barron D. 3D Modeling and Printing in Congenital Heart Surgery: Entering the Stage of Maturation. Front Pediatr 2021; 9:621672. [PMID: 33614554 PMCID: PMC7892770 DOI: 10.3389/fped.2021.621672] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 01/06/2021] [Indexed: 12/05/2022] Open
Abstract
3D printing allows the most realistic perception of the surgical anatomy of congenital heart diseases without the requirement of physical devices such as a computer screen or virtual headset. It is useful for surgical decision making and simulation, hands-on surgical training (HOST) and cardiovascular morphology teaching. 3D-printed models allow easy understanding of surgical morphology and preoperative surgical simulation. The most common indications for its clinical use include complex forms of double outlet right ventricle and transposition of the great arteries, anomalous systemic and pulmonary venous connections, and heterotaxy. Its utility in congenital heart surgery is indisputable, although it is hard to "scientifically" prove the impact of its use in surgery because of many confounding factors that contribute to the surgical outcome. 3D-printed models are valuable resources for morphology teaching. Educational models can be produced for almost all different variations of congenital heart diseases, and replicated in any number. HOST using 3D-printed models enables efficient education of surgeons in-training. Implementation of the HOST courses in congenital heart surgical training programs is not an option but an absolute necessity. In conclusion, 3D printing is entering the stage of maturation in its use for congenital heart surgery. It is now time for imagers and surgeons to find how to effectively utilize 3D printing and how to improve the quality of the products for improved patient outcomes and impact of education and training.
Collapse
Affiliation(s)
- Shi Joon Yoo
- Department of Diagnostic Imaging, The University of Toronto, Toronto, ON, Canada
- Department of Paediatrics–Division of Cardiology, The University of Toronto, Toronto, ON, Canada
- Center for Image Guided Innovation and Therapeutic Intervention, The University of Toronto, Toronto, ON, Canada
| | - Nabil Hussein
- Center for Image Guided Innovation and Therapeutic Intervention, The University of Toronto, Toronto, ON, Canada
- Department of Surgery-Division of Cardiovascular Surgery, Hospital for Sick Children, The University of Toronto, Toronto, ON, Canada
| | - Brandon Peel
- Center for Image Guided Innovation and Therapeutic Intervention, The University of Toronto, Toronto, ON, Canada
| | - John Coles
- Department of Surgery-Division of Cardiovascular Surgery, Hospital for Sick Children, The University of Toronto, Toronto, ON, Canada
| | - Glen S. van Arsdell
- Department of Surgery, David Geffen School of Medicine at the University of California Los Angeles, Los Angeles, CA, United States
- Department of Surgery, Mattel Children's Hospital at UCLA, Los Angeles, CA, United States
| | - Osami Honjo
- Department of Surgery-Division of Cardiovascular Surgery, Hospital for Sick Children, The University of Toronto, Toronto, ON, Canada
| | - Christoph Haller
- Department of Surgery-Division of Cardiovascular Surgery, Hospital for Sick Children, The University of Toronto, Toronto, ON, Canada
| | - Christopher Z. Lam
- Department of Diagnostic Imaging, The University of Toronto, Toronto, ON, Canada
| | - Mike Seed
- Department of Diagnostic Imaging, The University of Toronto, Toronto, ON, Canada
- Department of Paediatrics–Division of Cardiology, The University of Toronto, Toronto, ON, Canada
| | - David Barron
- Department of Surgery-Division of Cardiovascular Surgery, Hospital for Sick Children, The University of Toronto, Toronto, ON, Canada
| |
Collapse
|
29
|
Evaluation of 3D printing in planning, practicing, and training for endovascular lower extremity arterial interventions. TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY 2021; 29:20-26. [PMID: 33768977 PMCID: PMC7970071 DOI: 10.5606/tgkdc.dergisi.2021.20478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 09/07/2020] [Indexed: 11/21/2022]
Abstract
Background
In this study, we aimed to investigate the potential role of 3D-printed physical and digital anatomical models in pre-procedural planning, practice and training in lower extremity arterial interventions.
Methods
A total of 16 patients (9 males, 7 females; mean age: 72.1±1.5 years; range, 69 to 75 years) who underwent superficial femoral artery balloon angioplasty between February 2016 and April 2019 were retrospectively reviewed for vascular access site preference and balloon sizing. Pre-procedural computed tomography volumetric images used for diagnosis were analyzed and modeled with 3D printing. Procedural and 3D-based data regarding the size of the balloon and deployment sites and the severity of the stenosis were compared.
Results
Measurements obtained from 3D models manually and segmentation images from software were similar (p>0.05). Both were smaller than the actual size of balloons used (p<0.001). Stenosis severity was similar with manual and software methods and both were significantly lower than the reported quantitative angiographic measurements (p<0.001). Vascular access site preference was changed in five (31.2%) patients, when the model was simulated by a non-sterile practice on 3D-printed physical models. The wire and catheter selection differed in eight patients, while practicing with models.
Conclusion
The planning and practicing of lower extremity arterial procedures with 3D models may reduce operator-dependent variables, avoid unnecessary interventions, reduce endothelial damage, and increase procedural success. The 3D-printed models may be used for educational purposes for medical professionals.
Collapse
|
30
|
Mowers KL, Fullerton JB, Hicks D, Singh GK, Johnson MC, Anwar S. 3D Echocardiography Provides Highly Accurate 3D Printed Models in Congenital Heart Disease. Pediatr Cardiol 2021; 42:131-141. [PMID: 33083888 DOI: 10.1007/s00246-020-02462-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Accepted: 09/16/2020] [Indexed: 01/22/2023]
Abstract
Cardiac 3D printing is mainly performed from magnetic resonance imaging (MRI) and computed tomography (CT) 3D datasets, though anatomic detail of atrioventricular (AV) valves may be limited. 3D echo provides excellent visualization of AV valves. Thus, we tested the feasibility and accuracy of 3D printing from 3D echo in this pilot series of subjects with congenital heart disease (CHD), with a focus on valve anatomy. Five subjects with CHD were identified. 3D echo data were converted to 3D printable files and printed in collaboration with 3D Systems Healthcare (Golden, Colorado). A novel technique for valve modeling was utilized using commercially available software. Two readers (KM, SA) independently measured valve structures from 3D models and compared to source echo images. 3D printing was feasible for all cases. Table 1 shows measurements comparing 2D echo to 3D models. Bland Altman analysis showed close agreement and no significant bias between 2D and digital 3D models (mean difference 0.0, 95% CI 1.1 to - 1.1) or 2D vs printed 3D models, though with wider limits of agreement (mean difference - 0.3, 95% CI 1.9 to - 2.6). Accuracy of 3D models compared to 2D was within < 0.5 mm. This pilot study shows 3D echo datasets can be used to reliably print AV and semilunar valve structures in CHD. The 3D models are highly accurate compared to the source echo images. This is a novel and value-added technique that adds incremental information on cardiac anatomy over current methods.
Collapse
Affiliation(s)
- K L Mowers
- Division of Cardiology, Department of Pediatrics, Washington University in St. Louis School of Medicine, St. Louis, MO, USA
| | | | - D Hicks
- Division of Cardiology, Department of Pediatrics, Washington University in St. Louis School of Medicine, St. Louis, MO, USA
| | - G K Singh
- Division of Cardiology, Department of Pediatrics, Washington University in St. Louis School of Medicine, St. Louis, MO, USA
| | - M C Johnson
- Division of Cardiology, Department of Pediatrics, Washington University in St. Louis School of Medicine, St. Louis, MO, USA
| | - S Anwar
- School of Medicine, University of California, 1975 4th Street Second Floor, Room# A2421, UCSF Box 4029, San Francisco, CA, 94143, USA.
| |
Collapse
|
31
|
Corno AF, Durairaj S, Skinner GJ. Narrative review of assessing the surgical options for double outlet right ventricle. Transl Pediatr 2021; 10:165-176. [PMID: 33633949 PMCID: PMC7882294 DOI: 10.21037/tp-20-227] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
The individualized surgical approach in individuals with both arterial trunks arising from the morphologically right ventricle is dictated by the extreme morphological variability encountered in this setting, with each patient being unique. An individualized surgical approach has been designed to take account of the morphological variations, identifying the anatomy with the preoperative three-dimensional CT scan reconstruction. The key features have been considered the distance between tricuspid and pulmonary valves, the size and location of the interventricular communication, and the relationship between the outflow tracts. The surgical approach is tailored, whenever feasible, to create a connection between left ventricle and aorta, but primarily to achieve biventricular repair. Account has been taken of all available surgical options already reported in the literature, identifying the most suitable to provide the best outcomes for each unique morphology. To date, meaningful comparison between different reported surgical series has been difficult because of the marked variation of individual intracardiac morphology, and the lack of reports of specific surgical approaches for well-categorized groups of patients. Our approach, being tailored to the individual cardiac morphology, can be offered to any patient with this ventriculo-arterial connection. Given the difficulties of diagnosis, and the multiple therapeutic indications, very close collaboration between cardiologists and surgeons is indispensable for further progress in the understanding and management of this complex congenital cardiac lesion.
Collapse
Affiliation(s)
- Antonio F Corno
- Houston Children's Heart Institute, Hermann Children's Hospital, University of Texas Health, McGovern Medical School, Houston, TX, USA
| | - Saravanan Durairaj
- East Midlands Congenital Heart Centre, University Hospitals of Leicester, Leicester, UK
| | - Gregory J Skinner
- East Midlands Congenital Heart Centre, University Hospitals of Leicester, Leicester, UK
| |
Collapse
|
32
|
Ye W, Zhang X, Li T, Luo C, Yang L. Mixed-reality hologram for diagnosis and surgical planning of double outlet of the right ventricle: a pilot study. Clin Radiol 2020; 76:237.e1-237.e7. [PMID: 33309030 DOI: 10.1016/j.crad.2020.10.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Accepted: 10/30/2020] [Indexed: 10/22/2022]
Abstract
AIM To evaluate the mixed-reality (MR) hologram, a novel technology based on two-dimensional images, which simulates three-dimensional (3D) images and provides a dynamic and interactive alternative, for its usefulness in the diagnosis and surgical planning of double outlet of the right ventricle (DORV). MATERIALS AND METHODS Thirty-four patients who were suspected of DORV based on ultrasound findings underwent cardiac computed tomography angiography (CTA). The patients were assigned randomly to the MR holographic guidance (MRHG) group or the control group. For the patients in the MRHG group, the CTA images were converted into Standard Template Library (STL) files after segmentation, 3D reconstruction, colourisation, and transparentisation, and then exported for MR holographic visualisation. The CTA images of the patients in the control group were analysed using routine 3D reconstruction only. Diagnostic accuracy and surgical planning were compared between the two groups based on visualisation at surgery. RESULTS In the MRHG group, the 3D hologram observation was in concordance with the actual anatomical findings, and the DORV type was classified accurately in all patients. The diagnostic accuracy for the malformation was 95.5% in the MRHG group and 89.7% in the control group, but the difference was not significant (p=0.3). All the procedures were exactly the same as planned based on the 3D MR holographic model. The surgical planning time was shorter for the MRHG group (51.65 ± 11.11 min) than that for the control group (65.71 ± 18.07 min, p<0.05). CONCLUSION MR 3D holograms may provide a clear and deeper anatomical perception of DORV and improve surgical planning.
Collapse
Affiliation(s)
- W Ye
- Department of Cardiac Surgery, Chinese People's Liberation Army General Hospital, No. 28, Fu Xing Road, Hai Dian District, Beijing, China
| | - X Zhang
- Department of Radiology, Chinese People's Liberation Army General Hospital, No. 28, Fu Xing Road, Hai Dian District, Beijing, China
| | - T Li
- Department of Radiology, Chinese People's Liberation Army General Hospital, No. 28, Fu Xing Road, Hai Dian District, Beijing, China.
| | - C Luo
- Department of Radiology, Chinese People's Liberation Army General Hospital, No. 28, Fu Xing Road, Hai Dian District, Beijing, China
| | - L Yang
- Department of Radiology, Chinese People's Liberation Army General Hospital, No. 28, Fu Xing Road, Hai Dian District, Beijing, China
| |
Collapse
|
33
|
Clinical Applications of Patient-Specific 3D Printed Models in Cardiovascular Disease: Current Status and Future Directions. Biomolecules 2020; 10:biom10111577. [PMID: 33233652 PMCID: PMC7699768 DOI: 10.3390/biom10111577] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2020] [Revised: 11/19/2020] [Accepted: 11/19/2020] [Indexed: 01/09/2023] Open
Abstract
Three-dimensional (3D) printing has been increasingly used in medicine with applications in many different fields ranging from orthopaedics and tumours to cardiovascular disease. Realistic 3D models can be printed with different materials to replicate anatomical structures and pathologies with high accuracy. 3D printed models generated from medical imaging data acquired with computed tomography, magnetic resonance imaging or ultrasound augment the understanding of complex anatomy and pathology, assist preoperative planning and simulate surgical or interventional procedures to achieve precision medicine for improvement of treatment outcomes, train young or junior doctors to gain their confidence in patient management and provide medical education to medical students or healthcare professionals as an effective training tool. This article provides an overview of patient-specific 3D printed models with a focus on the applications in cardiovascular disease including: 3D printed models in congenital heart disease, coronary artery disease, pulmonary embolism, aortic aneurysm and aortic dissection, and aortic valvular disease. Clinical value of the patient-specific 3D printed models in these areas is presented based on the current literature, while limitations and future research in 3D printing including bioprinting of cardiovascular disease are highlighted.
Collapse
|
34
|
Al-Dulimi Z, Wallis M, Tan DK, Maniruzzaman M, Nokhodchi A. 3D printing technology as innovative solutions for biomedical applications. Drug Discov Today 2020; 26:360-383. [PMID: 33212234 DOI: 10.1016/j.drudis.2020.11.013] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 10/13/2020] [Accepted: 11/11/2020] [Indexed: 12/30/2022]
Abstract
3D printing was once predicted to be the third industrial revolution. Today, the use of 3D printing is found across almost all industries. This article discusses the latest 3D printing applications in the biomedical industry.
Collapse
Affiliation(s)
- Zaisam Al-Dulimi
- Arundel Building, Pharmaceutics Research Laboratory, School of Life Sciences, University of Sussex, Brighton, BN1 9QJ, UK
| | - Melissa Wallis
- Arundel Building, Pharmaceutics Research Laboratory, School of Life Sciences, University of Sussex, Brighton, BN1 9QJ, UK
| | - Deck Khong Tan
- Arundel Building, Pharmaceutics Research Laboratory, School of Life Sciences, University of Sussex, Brighton, BN1 9QJ, UK
| | - Mohammed Maniruzzaman
- Pharmaceutical Engineering and 3D Printing (PharmE3D) Lab, Division of Molecular Pharmaceutics and Drug Delivery, College of Pharmacy, University of Texas at Austin, PHR 4.214A, 2409 University Avenue, Stop A1920, Austin, TX 78712, USA.
| | - Ali Nokhodchi
- Arundel Building, Pharmaceutics Research Laboratory, School of Life Sciences, University of Sussex, Brighton, BN1 9QJ, UK.
| |
Collapse
|
35
|
Perens G, Chyu J, McHenry K, Yoshida T, Finn JP. Three-Dimensional Congenital Heart Models Created With Free Software and a Desktop Printer: Assessment of Accuracy, Technical Aspects, and Clinical Use. World J Pediatr Congenit Heart Surg 2020; 11:797-801. [PMID: 33164685 DOI: 10.1177/2150135120952072] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Three-dimensional printing is increasingly recognized as a valuable tool for congenital heart disease (CHD) procedural planning and education. Cost and complexity currently limit the more widespread adoption of this technology. We sought to demonstrate the accuracy of 3D printed CHD models created from contrast-enhanced magnetic resonance imaging (MRI) and computed tomography (CT) scans using free software and an inexpensive desktop fused filament fabrication (FFF) printer. METHODS Solid segmentations of the intracardiac blood pool were created with the program ITK-SNAP. Using the computer program Meshmixer, the segmentation model was hollowed to create a 0.8 mm shell with the inner surface representing endocardium. Three-dimensional models were created on an FFF printer. Four arteries and a ventricular septal defect (VSD) were 3D printed and measured for accuracy. Five models were used to assess candidacy for biventricular surgical repair and one to guide an interventional catheterization. RESULTS All six patients underwent intervention planned with the 3D models. The computer model shell walls all achieved specifications within 0.05 mm of the designated 0.8 mm thickness and the original solid blood pool segmentation fit within the hollowed 3D model. The 3D printed arteries and VSD all measured accurately to within 0.5 mm of their source computer model. CONCLUSION Accurate 3D printed models of complex, pediatric CHD may be created from volumetric MRI and CT studies using free online software and printed on an inexpensive desktop printer.
Collapse
Affiliation(s)
- Gregory Perens
- 21785UCLA Mattel Children's Hospital, Children's Heart Center, Los Angeles, CA, USA
| | - Justin Chyu
- 21785UCLA Mattel Children's Hospital, Children's Heart Center, Los Angeles, CA, USA
| | - Kevin McHenry
- 21785UCLA Mattel Children's Hospital, Children's Heart Center, Los Angeles, CA, USA
| | - Takegawa Yoshida
- Diagnostic Cardiovascular Imaging Laboratory, Department of Radiology, 12222David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| | - J Paul Finn
- Diagnostic Cardiovascular Imaging Laboratory, Department of Radiology, 12222David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| |
Collapse
|
36
|
Zhu Y, Zhang XE, Li Q, Yao H. Three-dimensional printing in a patient with pulmonary artery pseudoaneurysm and complex congenital heart disease-A case report. Clin Case Rep 2020; 8:2107-2110. [PMID: 33235737 PMCID: PMC7669418 DOI: 10.1002/ccr3.2950] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Revised: 10/07/2019] [Accepted: 10/21/2019] [Indexed: 11/28/2022] Open
Abstract
3D-printing is a powerful tool in patients with complex anatomy undergoing cardiac surgery.
Collapse
Affiliation(s)
- Yueqian Zhu
- Cardiovascular CenterThe 2nd affiliated Hospital of Nanjing Medical UniversityNanjingChina
| | - Xun E. Zhang
- Cardiovascular CenterThe 2nd affiliated Hospital of Nanjing Medical UniversityNanjingChina
| | - Qingguo Li
- Cardiovascular CenterThe 2nd affiliated Hospital of Nanjing Medical UniversityNanjingChina
| | - Hao Yao
- Cardiovascular CenterThe 2nd affiliated Hospital of Nanjing Medical UniversityNanjingChina
| |
Collapse
|
37
|
Four-dimensional virtual reality cine cardiac models using free open-source software. Pediatr Radiol 2020; 50:1617-1623. [PMID: 32681236 DOI: 10.1007/s00247-020-04758-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 05/10/2020] [Accepted: 06/17/2020] [Indexed: 10/23/2022]
Abstract
This is a proof-of-concept study to create a four-dimensional (4-D) cine model of the heart and visualize it in virtual reality by using freely available open-source software and inexpensive hardware. Four-dimensional cine models allow for real-time visualization of cardiac structures during processes such as complex congenital heart disease. Such models can be used for patient and trainee education, and potentially for surgical planning. Currently, 3-D printed models are more commonly used, but they are static, showing only one selected phase of the cardiac cycle. Second, they are limited by the selection of clipping planes before printing. Four-dimensional segmentation and virtual reality visualization overcome these limitations. Currently, most of the work in virtual/augmented reality models involves the segmentation of one cardiac phase or the use of expensive software for multiphase segmentation. In this study, we show an approach for multiphase cardiac segmentation as well as its display using free open-source software and relatively inexpensive hardware.
Collapse
|
38
|
Kang SL, Shkumat N, Dragulescu A, Guerra V, Padfield N, Krutikov K, Chiasson DA, Chaturvedi RR, Yoo SJ, Benson LN. Mixed-reality view of cardiac specimens: a new approach to understanding complex intracardiac congenital lesions. Pediatr Radiol 2020; 50:1610-1616. [PMID: 32613358 DOI: 10.1007/s00247-020-04740-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 03/25/2020] [Accepted: 05/22/2020] [Indexed: 11/29/2022]
Abstract
Digital reality is an emerging platform for three-dimensional representation of medical imaging data. In this technical innovation paper, the authors evaluated the accuracy and utility of mixed-reality technology in the morphological evaluation of complex congenital heart disease. The authors converted CT datasets of 12 heart specimens with different subtypes of double-outlet right ventricle to stereoscopic images and interrogated them using a mixed-reality system. The morphological features identified on the stereoscopic models were compared with findings at macroscopic examination of the actual heart specimens. The results showed that the mixed-reality system provided highly accurate stereoscopic display of spatially complex congenital cardiac lesions, with interactive features that might enhance 3-D understanding of morphology. Additionally, the authors found that high-resolution digital reproduction of cardiac specimens using clinical CT scanners is feasible for preservation and educational purposes.
Collapse
Affiliation(s)
- Sok-Leng Kang
- Department of Pediatrics, Division of Cardiology, Labatt Family Heart Centre, Hospital for Sick Children, University of Toronto School of Medicine, 555 University Ave., Toronto, ON, M5G 1X8, Canada
| | - Nicholas Shkumat
- Department of Diagnostic Imaging, Hospital for Sick Children, University of Toronto School of Medicine, Toronto, ON, Canada
| | - Andreea Dragulescu
- Department of Pediatrics, Division of Cardiology, Labatt Family Heart Centre, Hospital for Sick Children, University of Toronto School of Medicine, 555 University Ave., Toronto, ON, M5G 1X8, Canada
| | - Vitor Guerra
- Department of Pediatrics, Division of Cardiology, Labatt Family Heart Centre, Hospital for Sick Children, University of Toronto School of Medicine, 555 University Ave., Toronto, ON, M5G 1X8, Canada
| | - Nancy Padfield
- Department of Diagnostic Imaging, Hospital for Sick Children, University of Toronto School of Medicine, Toronto, ON, Canada
| | - Konstantin Krutikov
- Department of Paediatric Laboratory Medicine, Hospital for Sick Children, University of Toronto School of Medicine, Toronto, ON, Canada
| | - David A Chiasson
- Department of Paediatric Laboratory Medicine, Hospital for Sick Children, University of Toronto School of Medicine, Toronto, ON, Canada
| | - Rajiv R Chaturvedi
- Department of Pediatrics, Division of Cardiology, Labatt Family Heart Centre, Hospital for Sick Children, University of Toronto School of Medicine, 555 University Ave., Toronto, ON, M5G 1X8, Canada
| | - Shi-Joon Yoo
- Department of Diagnostic Imaging, Hospital for Sick Children, University of Toronto School of Medicine, Toronto, ON, Canada
| | - Lee N Benson
- Department of Pediatrics, Division of Cardiology, Labatt Family Heart Centre, Hospital for Sick Children, University of Toronto School of Medicine, 555 University Ave., Toronto, ON, M5G 1X8, Canada.
| |
Collapse
|
39
|
Goo HW, Park SJ, Yoo SJ. Advanced Medical Use of Three-Dimensional Imaging in Congenital Heart Disease: Augmented Reality, Mixed Reality, Virtual Reality, and Three-Dimensional Printing. Korean J Radiol 2020; 21:133-145. [PMID: 31997589 PMCID: PMC6992436 DOI: 10.3348/kjr.2019.0625] [Citation(s) in RCA: 59] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2019] [Accepted: 10/24/2019] [Indexed: 12/15/2022] Open
Abstract
Three-dimensional (3D) imaging and image reconstruction play a prominent role in the diagnosis, treatment planning, and post-therapeutic monitoring of patients with congenital heart disease. More interactive and realistic medical experiences take advantage of advanced visualization techniques like augmented, mixed, and virtual reality. Further, 3D printing is now used in medicine. All these technologies improve the understanding of the complex morphologies of congenital heart disease. In this review article, we describe the technical advantages and disadvantages of various advanced visualization techniques and their medical applications in the field of congenital heart disease. In addition, unresolved issues and future perspectives of these evolving techniques are described.
Collapse
Affiliation(s)
- Hyun Woo Goo
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.
| | - Sang Joon Park
- Department of Radiology, Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
| | - Shi Joon Yoo
- Department of Diagnostic Imaging, The Hospital for Sick Children, University of Toronto, Toronto, Canada
| |
Collapse
|
40
|
Cen J, Liufu R, Wen S, Qiu H, Liu X, Chen X, Yuan H, Huang M, Zhuang J. Three-Dimensional Printing, Virtual Reality and Mixed Reality for Pulmonary Atresia: Early Surgical Outcomes Evaluation. Heart Lung Circ 2020; 30:296-302. [PMID: 32863113 DOI: 10.1016/j.hlc.2020.03.017] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2019] [Revised: 01/07/2020] [Accepted: 03/28/2020] [Indexed: 11/16/2022]
Abstract
BACKGROUND Single-stage unifocalisation for pulmonary atresia (PA) with ventricular septal defect (VSD) and major aortopulmonary collateral arteries (MAPCA) requires a high degree of three-dimensional (3D) anatomical imagination. A previous study has reported the application of a 3D-printed heart model with virtual reality (VR) or mixed reality (MR). However, few studies have evaluated the surgical outcomes of the 3D model with VR or MR in PA/VSD patients. METHODS Three-dimensional (3D) heart models of five selected PA/VSD patients were derived from traditional imageology of their hearts. Using VR glasses, the 3D models were also visualised in the operating room. Both the 3D-printed heart models and preoperative evaluation by VR were used in the five selected patients for surgical simulation and better anatomical understanding. Mixed reality holograms were used as perioperative assistive tools. Surgical outcomes were assessed, including in-hospital and early follow-up clinical data. RESULTS The use of these three new technologies had favourable feedback from the surgeons on intraoperative judgment. There were no in-hospital or early deaths. No reintervention was required until the last follow-up. Three (3) patients developed postoperative complications: one had right bundle branch block and ST-segment change, one had chest drainage >7 days (>40 mL/day) and one had pneumonia. CONCLUSION The preoperative application of a 3D-printed heart model with VR or MR helped in aligning the surgical field. These technologies improved the understanding of complicated cardiac anatomy and achieved acceptable surgical outcomes as guiding surgical planning.
Collapse
Affiliation(s)
- Jianzheng Cen
- Department of Cardiovascular Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Rong Liufu
- Cardiovascular Intensive Care Unit, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Shusheng Wen
- Department of Cardiovascular Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Hailong Qiu
- Department of Cardiovascular Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Xiaobin Liu
- Department of Cardiovascular Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Xiaokun Chen
- Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Haiyun Yuan
- Department of Cardiovascular Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Meiping Huang
- Radiology Department, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
| | - Jian Zhuang
- Department of Cardiovascular Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
| |
Collapse
|
41
|
Joshi A, Ghadimi Mahani M, Dorfman A, Balasubramanian S. Cardiac MR Evaluation of Repaired Tetralogy of Fallot. Semin Roentgenol 2020; 55:290-300. [PMID: 32859345 DOI: 10.1053/j.ro.2020.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Aparna Joshi
- Department of Radiology, Section of Pediatric Radiology, Michigan Medicine, Ann Arbor, MI.
| | - Maryam Ghadimi Mahani
- Department of Radiology, Section of Pediatric Radiology and Division of Cardiothoracic Radiology, Michigan Medicine, Ann Arbor, MI
| | - Adam Dorfman
- Department of Pediatrics, Division of Pediatric Cardiology, Michigan Medicine, Ann Arbor, MI
| | - Sowmya Balasubramanian
- Department of Pediatrics, Division of Pediatric Cardiology, Michigan Medicine, Ann Arbor, MI
| |
Collapse
|
42
|
Vukicevic M, Filippini S, Little SH. Patient-Specific Modeling for Structural Heart Intervention: Role of 3D Printing Today and Tomorrow CME. Methodist Debakey Cardiovasc J 2020; 16:130-137. [PMID: 32670473 DOI: 10.14797/mdcj-16-2-130] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Structural heart interventions (SHIs) are increasingly applicable in a wide range of heart defects, but the intricate and dynamic nature of cardiac structures can make SHIs challenging to perform. Three-dimensional (3D) printed modeling integrates advanced clinical imaging and 3D printing technology to replicate patient-specific anatomy for comprehensive planning and simulation of SHIs. This review discusses the basic principles of patient-specific 3D print model development, print material selection, and model fabrication and highlights how cardiovascular 3D printing can be used in preprocedural planning, device sizing, enhanced communication, and procedure simulation.
Collapse
Affiliation(s)
- Marija Vukicevic
- HOUSTON METHODIST DEBAKEY HEART & VASCULAR CENTER, HOUSTON METHODIST HOSPITAL, HOUSTON, TEXAS
| | - Stefano Filippini
- HOUSTON METHODIST DEBAKEY HEART & VASCULAR CENTER, HOUSTON METHODIST HOSPITAL, HOUSTON, TEXAS
| | - Stephen H Little
- HOUSTON METHODIST DEBAKEY HEART & VASCULAR CENTER, HOUSTON METHODIST HOSPITAL, HOUSTON, TEXAS
| |
Collapse
|
43
|
Stereoscopic Three-Dimensional Visualization for Congenital Heart Surgery Planning: Surgeons' Perspectives. J Am Soc Echocardiogr 2020; 33:775-777. [DOI: 10.1016/j.echo.2020.02.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 02/03/2020] [Accepted: 02/03/2020] [Indexed: 11/22/2022]
|
44
|
Byl JL, Sholler R, Gosnell JM, Samuel BP, Vettukattil JJ. Moving beyond two-dimensional screens to interactive three-dimensional visualization in congenital heart disease. Int J Cardiovasc Imaging 2020; 36:1567-1573. [PMID: 32335820 DOI: 10.1007/s10554-020-01853-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2019] [Accepted: 04/15/2020] [Indexed: 12/11/2022]
Abstract
Beginning with the discovery of X-rays to the development of three-dimensional (3D) imaging, improvements in acquisition, post-processing, and visualization have provided clinicians with detailed information for increasingly accurate medical diagnosis and clinical management. This paper highlights advances in imaging technologies for congenital heart disease (CHD), medical adoption, and future developments required to improve pre-procedural and intra-procedural guidance.
Collapse
Affiliation(s)
- John L Byl
- Congenital Heart Center, Spectrum Health Helen DeVos Children's Hospital, Grand Rapids, MI, USA
| | - Rebecca Sholler
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Jordan M Gosnell
- Congenital Heart Center, Spectrum Health Helen DeVos Children's Hospital, Grand Rapids, MI, USA
| | - Bennett P Samuel
- Congenital Heart Center, Spectrum Health Helen DeVos Children's Hospital, Grand Rapids, MI, USA
| | - Joseph J Vettukattil
- Congenital Heart Center, Spectrum Health Helen DeVos Children's Hospital, Grand Rapids, MI, USA. .,Pediatrics and Human Development, Michigan State University College of Human Medicine, Grand Rapids, MI, USA.
| |
Collapse
|
45
|
Evaluation of 3D printed carotid anatomical models in planning carotid artery stenting. TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY 2020; 28:294-300. [PMID: 32551159 DOI: 10.5606/tgkdc.dergisi.2020.18939] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Accepted: 01/31/2020] [Indexed: 12/18/2022]
Abstract
Background We aimed to investigate the potential role of threedimensional printed anatomical models in pre-procedural planning, practice, and selection of carotid artery stent and embolic protection device size and location. Methods A total of 16 patients (10 males, 6 females; mean age 75.6±4.7 years; range, 68 to 81 years) who underwent carotid artery stenting with an embolic protection device between January 2017 and February 2019 were retrospectively analyzed. The sizing was based on intraprocedural angiography findings with the same brand stent using distal protection device. Pre-procedural computed tomography angiography images used for diagnosis were obtained and modeled with three-dimensional printing method. Pre-procedural and threedimensional data regarding the size of stents and protection devices and implantation sites were compared. Results Measurements obtained from three-dimensional models manually and segmentation images from software were found to be similar and both were smaller than actually used for stent and embolic protection device sizes. The rates of carotid artery stenosis were similar with manual and software methods, but were lower than the quantitative angiographic measurements. Device implantation sites detected by the manual and software methods were different than the actual setting. Conclusion The planning and practicing of procedure with threedimensional models may reduce the operator-dependent variables, shorten the operation time, decrease X-ray exposure, and increase the procedural success.
Collapse
|
46
|
Koca Tari C, Erdol MA, Ilkay E. Printing the Procedure: Successful Closure of a Coronary Cameral Fistula With 3-Dimensional Model. JACC Case Rep 2020; 2:488-492. [PMID: 34317271 PMCID: PMC8311617 DOI: 10.1016/j.jaccas.2019.11.047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 10/24/2019] [Accepted: 11/20/2019] [Indexed: 06/13/2023]
Abstract
Cardiac 3-dimensional printing for pre-procedural planning of structural heart procedures is a promising new tool. Despite current potential drawbacks, 3-dimensional models can help cardiologists better understand and treat complex cardiac defects. We describe a successful coronary cameral fistula closure planned with the aid of a 3-dimensional model. (Level of Difficulty: Advanced.).
Collapse
Affiliation(s)
| | | | - Erdogan Ilkay
- Department of Cardiology, Liv Hospital Ankara, Ankara, Turkey
| |
Collapse
|
47
|
Biglino G, Caputo M. Commentary: On the road toward routine use of 3-dimensional techniques in complex congenital surgery. JTCVS Tech 2020; 1:88-89. [PMID: 34317726 PMCID: PMC8288822 DOI: 10.1016/j.xjtc.2020.01.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Revised: 12/13/2019] [Accepted: 01/03/2020] [Indexed: 11/24/2022] Open
Affiliation(s)
- Giovanni Biglino
- Bristol Medical School, University of Bristol, Bristol, United Kingdom.,Bristol Heart Institute, University Hospitals Bristol, Bristol, United Kingdom.,National Heart and Lung Institute, Imperial College London, London, United Kingdom
| | - Massimo Caputo
- Bristol Medical School, University of Bristol, Bristol, United Kingdom.,Bristol Heart Institute, University Hospitals Bristol, Bristol, United Kingdom
| |
Collapse
|
48
|
Tomov ML, Cetnar A, Do K, Bauser‐Heaton H, Serpooshan V. Patient-Specific 3-Dimensional-Bioprinted Model for In Vitro Analysis and Treatment Planning of Pulmonary Artery Atresia in Tetralogy of Fallot and Major Aortopulmonary Collateral Arteries. J Am Heart Assoc 2019; 8:e014490. [PMID: 31818221 PMCID: PMC6951056 DOI: 10.1161/jaha.119.014490] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Accepted: 11/07/2019] [Indexed: 12/12/2022]
Abstract
Background Tetralogy of Fallot with major aortopulmonary collateral arteries is a heterogeneous form of pulmonary artery (PA) stenosis that requires multiple forms of intervention. We present a patient-specific in vitro platform capable of sustained flow that can be used to train proceduralists and surgical teams in current interventions, as well as in developing novel therapeutic approaches to treat various vascular anomalies. Our objective is to develop an in vitro model of PA stenosis based on patient data that can be used as an in vitro phantom to model cardiovascular disease and explore potential interventions. Methods and Results From patient-specific scans obtained via computer tomography or 3-dimensional (3D) rotational angiography, we generated digital 3D models of the arteries. Subsequently, in vitro models of tetralogy of Fallot with major aortopulmonary collateral arteries were first 3D printed using biocompatible resins and next bioprinted using gelatin methacrylate hydrogel to simulate neonatal vasculature or second-order branches of an older patient with tetralogy of Fallot with major aortopulmonary collateral arteries. Printed models were used to study creation of extraluminal connection between an atretic PA and a major aortopulmonary collateral artery using a catheter-based interventional method. Following the recanalization, engineered PA constructs were perfused and flow was visualized using contrast agents and x-ray angiography. Further, computational fluid dynamics modeling was used to analyze flow in the recanalized model. Conclusions New 3D-printed and computational fluid dynamics models for vascular atresia were successfully created. We demonstrated the unique capability of a printed model to develop a novel technique for establishing blood flow in atretic vessels using clinical imaging, together with 3D bioprinting-based tissue engineering techniques. Additive biomanufacturing technologies can enable fabrication of functional vascular phantoms to model PA stenosis conditions that can help develop novel clinical applications.
Collapse
Affiliation(s)
- Martin L. Tomov
- Department of Biomedical EngineeringEmory University School of Medicine and Georgia Institute of TechnologyAtlantaGA
| | - Alexander Cetnar
- Department of Biomedical EngineeringEmory University School of Medicine and Georgia Institute of TechnologyAtlantaGA
| | - Katherine Do
- Department of PediatricsEmory University School of MedicineAtlantaGA
| | - Holly Bauser‐Heaton
- Department of PediatricsEmory University School of MedicineAtlantaGA
- Children's Healthcare of AtlantaAtlantaGA
- Sibley Heart Center at Children's Healthcare of AtlantaAtlantaGA
| | - Vahid Serpooshan
- Department of Biomedical EngineeringEmory University School of Medicine and Georgia Institute of TechnologyAtlantaGA
- Department of PediatricsEmory University School of MedicineAtlantaGA
- Children's Healthcare of AtlantaAtlantaGA
| |
Collapse
|
49
|
Bartel T, Müller S. 3-Dimensional Printing in Personalized Interventional Cardiology and Cardiac Surgery. JACC Case Rep 2019; 1:538-539. [PMID: 34316873 PMCID: PMC8288587 DOI: 10.1016/j.jaccas.2019.08.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Thomas Bartel
- Heart & Vascular Institute, Cleveland Clinic Abu Dhabi, Dubai, United Arab Emirates
| | - Silvana Müller
- University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University Innsbruck, Innsbruck, Austria
| |
Collapse
|
50
|
Zhang J, Hu Q, Wang S, Tao J, Gou M. Digital Light Processing Based Three-dimensional Printing for Medical Applications. Int J Bioprint 2019; 6:242. [PMID: 32782984 PMCID: PMC7415858 DOI: 10.18063/ijb.v6i1.242] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Accepted: 10/29/2019] [Indexed: 02/08/2023] Open
Abstract
An additive manufacturing technology based on projection light, digital light processing (DLP), three-dimensional (3D) printing, has been widely applied in the field of medical products production and development. The precision projection light, reflected by a digital micromirror device of million pixels instead of one focused point, provides this technology both printing accuracy and printing speed. In particular, this printing technology provides a relatively mild condition to cells due to its non-direct contact. This review introduces the DLP-based 3D printing technology and its applications in medicine, including precise medical devices, functionalized artificial tissues, and specific drug delivery systems. The products are particularly discussed for their significance in medicine. This review indicates that the DLP-based 3D printing technology provides a potential tool for biological research and clinical medicine. While, it is faced to the challenges of scale-up of its usage and waiting period of regulatory approval.
Collapse
Affiliation(s)
- Jiumeng Zhang
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610065, China
| | - Qipeng Hu
- Department of Thoracic Oncology, West China Hospital of Sichuan University, 610041, Chengdu, Sichuan, China
| | - Shuai Wang
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610065, China
| | - Jie Tao
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610065, China
| | - Maling Gou
- State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610065, China
| |
Collapse
|