1
|
Dias Neves MA, Mendes Pinto I. AptaShield: A Universal Signal-Transduction System for Fast and High-Throughput Optical Molecular Biosensing. ACS Sens 2024; 9:1756-1762. [PMID: 38620013 PMCID: PMC11059090 DOI: 10.1021/acssensors.3c02762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 03/11/2024] [Accepted: 03/22/2024] [Indexed: 04/17/2024]
Abstract
Biosensing technologies are often described to provide facile, sensitive, and minimally to noninvasive detection of molecular analytes across diverse scientific, environmental, and clinical diagnostic disciplines. However, commercialization has been very limited mostly due to the difficulty of biosensor reconfiguration for different analyte(s) and limited high-throughput capabilities. The immobilization of different biomolecular probes (e.g., antibodies, peptides, and aptamers) requires the sensor surface chemistry to be tailored to provide optimal probe coupling, orientation, and passivation and prevent nonspecific interactions. To overcome these challenges, here we report the development of a solution-phase biosensor consisting of an engineered aptamer, the AptaShield, capable of universally binding to any antigen recognition site (Fab') of fluorescently labeled immunoglobulins (IgG) produced in rabbits. The resulting AptaShield biosensor relies on a low affinity dynamic equilibrium between the fluorescently tagged aptamer and IgG to generate a specific Förster resonance energy transfer (FRET) signal. As the analyte binds to the IgG, the AptaShield DNA aptamer-IgG complex dissociates, leading to an analyte concentration-dependent decrease of the FRET signal. The biosensor demonstrates high selectivity, specificity, and reproducibility for analyte quantification in different biological fluids (e.g., urine and blood serum) in a one-step and low sample volume (0.5-6.25 μL) format. The AptaShield provides a universal signal transduction mechanism as it can be coupled to different rabbit antibodies without the need for aptamer modification, therefore representing a robust high-throughput solution-phase technology suitable for point-of-care applications, overcoming the current limitations of gold standard enzyme-linked immunosorbent assays (ELISA) for molecular profiling.
Collapse
Affiliation(s)
- Miguel António Dias Neves
- Institute
for Research and Innovation in Health (i3S), University of Porto, 4200-135 Porto, Portugal
- Molecular
and Analytical Medicine Laboratory, Department of Biomedicine, Faculty
of Medicine, University of Porto, 4200-319 Porto, Portugal
| | - Inês Mendes Pinto
- Institute
for Research and Innovation in Health (i3S), University of Porto, 4200-135 Porto, Portugal
- Molecular
and Analytical Medicine Laboratory, Department of Biomedicine, Faculty
of Medicine, University of Porto, 4200-319 Porto, Portugal
| |
Collapse
|
2
|
Maestri C, Plancher L, Duthoit A, Hébert RL, Di Martino P. Fungal Biodegradation of Polyurethanes. J Fungi (Basel) 2023; 9:760. [PMID: 37504748 PMCID: PMC10381151 DOI: 10.3390/jof9070760] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/14/2023] [Accepted: 07/17/2023] [Indexed: 07/29/2023] Open
Abstract
Polyurethanes (PURs) are versatile polymers used in a wide variety of fields, such as the medical, automotive, textile, thermal insulation, and coating industries as well as many everyday objects. Many PURs have applications that require a long service life, sometimes with exposure to aggressive conditions. They can undergo different types of physicochemical and biological degradation, but they are not compostable, and many of them constitute persistent waste in the environment. Although both bacteria and fungi can be involved in the degradation of PURs, fungi are often the main biodegradation agents. The chemical structure of PURs determines their degree of biodegradation. Fungal biodegradation of PURs is linked to the production of enzymes, mainly esterases and proteases, alongside laccases, peroxidases, and tyrosinases, which can modify the structure of polyurethane compounds by forming carbonyl groups. The experimental analysis of the biodegradation of PUR can be carried out by bringing the polymer into contact with a mold in pure culture or with a microbial consortium. Then, global measurements can be taken, such as weight loss, tensile tests, or the ability of microorganisms to grow in the presence of PUR as the sole carbon source. The analysis of the chemical structure of the polymer and its degradation products after fungal growth can confirm biodegradation and specify the mechanism. The main avenues of future research are directed towards the development of fully biodegradable PURs and, on the contrary, towards the development of PURs that are more resistant to degradation phenomena, in particular biodegradation, for applications where the material is in contact with living organisms.
Collapse
Affiliation(s)
- Clotilde Maestri
- Laboratoire ERRMECe, Cergy Paris University, 1 Rue Descartes, 95000 Neuville-sur-Oise, France
- Laboratoire GEC, Cergy Paris University, 1 Rue Descartes, 95000 Neuville-sur-Oise, France
- SPPM-27 Rue Raffet, 75016 Paris, France
| | - Lionel Plancher
- Laboratoire ERRMECe, Cergy Paris University, 1 Rue Descartes, 95000 Neuville-sur-Oise, France
- Laboratoire GEC, Cergy Paris University, 1 Rue Descartes, 95000 Neuville-sur-Oise, France
| | | | - Ronan L Hébert
- Laboratoire GEC, Cergy Paris University, 1 Rue Descartes, 95000 Neuville-sur-Oise, France
| | - Patrick Di Martino
- Laboratoire ERRMECe, Cergy Paris University, 1 Rue Descartes, 95000 Neuville-sur-Oise, France
| |
Collapse
|
3
|
Macdonald B, Zhang C, Chen Z, Tuteja A. Polysiloxane-Based Liquid-like Layers for Reducing Polymer and Wax Fouling. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:274-284. [PMID: 36583570 DOI: 10.1021/acs.langmuir.2c02489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Surface fouling occurs when undesired matter adheres and accumulates on a surface, resulting in a decrease or loss of functionality. Polymer and wax fouling can cause costly blockages to crude oil pipelines, clog jet fuel injectors, foul chemical reaction vessels, and significantly decrease the efficiency of heat exchangers. Fouling occurs in many forms but can be segmented based on adherent size, modulus, and chemical functionality. Depending on the foulant, surface design strategies can vary greatly. Few strategies exist to prevent the buildup of wax and polymers on surfaces. In this report, we investigate the potential of highly disordered, siloxane liquid-like layers as a strategy for reducing wax and polymer deposition. In our tests, it was found that the liquid-like layers developed here were able to reduce postadsorption roughness for polymer and wax by as much as 35- and 47-fold, respectively, when compared to the control. SFG was utilized to investigate the molecular-level interfacial properties for each of the modified surfaces to help understand the antifouling mechanism. The data showed that the likely higher grafting density and a large degree of random conformational freedom at the liquid-surface interface make the developed siloxane-covered surfaces energetically unfavorable for polymer and wax accretion.
Collapse
Affiliation(s)
- Brian Macdonald
- Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Biointerfaces Institute, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Chengcheng Zhang
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, Michigan 48109, United States
| | - Zhan Chen
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, Michigan 48109, United States
| | - Anish Tuteja
- Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Biointerfaces Institute, University of Michigan, Ann Arbor, Michigan 48109, United States
- Department of Chemical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Department of Macromolecular Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
4
|
Benková Z, Čakánek P, Cordeiro MNDS. Adsorption of Peptides onto Carbon Nanotubes Grafted with Poly(ethylene Oxide) Chains: A Molecular Dynamics Simulation Study. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:3795. [PMID: 36364570 PMCID: PMC9655739 DOI: 10.3390/nano12213795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 10/17/2022] [Accepted: 10/24/2022] [Indexed: 06/16/2023]
Abstract
Carbon nanotubes (CNTs) display exceptional properties that predispose them to wide use in technological or biomedical applications. To remove the toxicity of CNTs and to protect them against undesired protein adsorption, coverage of the CNT sidewall with poly(ethylene oxide) (PEO) is often considered. However, controversial results on the antifouling effectiveness of PEO layers have been reported so far. In this work, the interactions of pristine CNT and CNT covered with the PEO chains at different grafting densities with polyglycine, polyserine, and polyvaline are studied using molecular dynamics simulations in vacuum, water, and saline environments. The peptides are adsorbed on CNT in all investigated systems; however, the adsorption strength is reduced in aqueous environments. Save for one case, addition of NaCl at a physiological concentration to water does not appreciably influence the adsorption and structure of the peptides or the grafted PEO layer. It turns out that the flexibility of the peptide backbone allows the peptide to adopt more asymmetric conformations which may be inserted deeper into the grafted PEO layer. Water molecules disrupt the internal hydrogen bonds in the peptides, as well as the hydrogen bonds formed between the peptides and the PEO chains.
Collapse
Affiliation(s)
- Zuzana Benková
- Polymer Institute, Slovak Academy of Sciences, Dúbravská Cesta 9, 845 41 Bratislava, Slovakia
| | - Peter Čakánek
- Polymer Institute, Slovak Academy of Sciences, Dúbravská Cesta 9, 845 41 Bratislava, Slovakia
| | - Maria Natália D. S. Cordeiro
- LAQV@REQUIMTE, Department of Chemistry and Biochemistry, University of Porto, Rua do Campo Alegre s/n, 4169-007 Porto, Portugal
| |
Collapse
|
5
|
De La Franier B, Asker D, Hatton B, Thompson M. Long-Term Reduction of Bacterial Adhesion on Polyurethane by an Ultra-Thin Surface Modifier. Biomedicines 2022; 10:979. [PMID: 35625716 PMCID: PMC9138992 DOI: 10.3390/biomedicines10050979] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 04/12/2022] [Accepted: 04/21/2022] [Indexed: 11/16/2022] Open
Abstract
Indwelling urinary catheters are employed widely to relieve urinary retention in patients. A common side effect of the use of these catheters is the formation of urinary tract infections (UTIs), which can lead not only to severe medical complications, but even to death. A number of approaches have been used to attempt reduction in the rate of UTI development in catheterized patients, which include the application of antibiotics and modification of the device surface by coatings. Many of these coatings have not seen use on catheters in medical settings due to either the high cost of their implementation, their long-term stability, or their safety. In previous work, it has been established that the simple, stable, and easily applicable sterilization surface coating 2-(3-trichlorosilylpropyloxy)-ethyl hydroxide (MEG-OH) can be applied to polyurethane plastic, where it greatly reduces microbial fouling from a variety of species for a 1-day time period. In the present work, we establish that this coating is able to remain stable and provide a similarly large reduction in fouling against Escherichia coli and Staphylococcus aureus for time periods in an excess of 30 days. This non-specific coating functioned against both Gram-positive and Gram-negative bacteria, providing a log 1.1 to log 1.9 reduction, depending on the species and day. This stability and continued efficacy greatly suggest that MEG-OH may be capable of providing a solution to the UTI issue which occurs with urinary catheters.
Collapse
Affiliation(s)
- Brian De La Franier
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6, Canada;
| | - Dalal Asker
- Department of Materials Science, University of Toronto, 184 College Street, Toronto, ON M5S 3E4, Canada; or (D.A.); (B.H.)
- Food Science and Technology Department, Faculty of Agriculture, Alexandria University, Alexandria 21545, Egypt
| | - Benjamin Hatton
- Department of Materials Science, University of Toronto, 184 College Street, Toronto, ON M5S 3E4, Canada; or (D.A.); (B.H.)
| | - Michael Thompson
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6, Canada;
| |
Collapse
|
6
|
Interaction of Lipopolysaccharide-Spiked Blood with Anti-Fouling Polymyxin B-Modified Glass. MATERIALS 2022; 15:ma15041551. [PMID: 35208091 PMCID: PMC8876862 DOI: 10.3390/ma15041551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 02/07/2022] [Accepted: 02/14/2022] [Indexed: 11/20/2022]
Abstract
Bacterial endotoxin, also known as lipopolysaccharide (LPS), plays a major role in the initiation of sepsis, a severe inflammatory condition. Removal of the toxin from blood is one accepted method of patient treatment. Polymyxin B (PMB)-modified columns have been employed successfully for this purpose via extra-corporeal blood-flow systems that incorporate a cartridge for toxin removal. Herein we demonstrate that PMB-modified glass beads are able to reduce the presence of LPS competitively with the equivalent fiber column used in a commercial cartridge. Analysis by gas chromatography-mass spectrometry and ELISA of released fatty acids from the toxin indicates that PMB does not physically capture or significantly remove LPS from the blood samples. In reality, interaction between the surface-bound PMB and the toxin may lead to disaggregation or monomerization of LPS aggregates. As aggregates are the bioactive form of LPS, it is possible that the monomerization of these entities may be the mechanism by which their toxicity is reduced. Moreover, this work indicates that LPS monomers are stabilized subsequent to disaggregation induced by PMB.
Collapse
|
7
|
De La Franier B, Thompson M. Surface Adsorption of the Cancer Biomarker Lysophosphatidic Acid in Serum Studied by Acoustic Wave Biosensor. MATERIALS (BASEL, SWITZERLAND) 2021; 14:4158. [PMID: 34361352 PMCID: PMC8347737 DOI: 10.3390/ma14154158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 07/21/2021] [Accepted: 07/22/2021] [Indexed: 11/16/2022]
Abstract
The thickness shear mode acoustic wave device is of interest for the sensing of biomarkers for diseases in various biological fluids, but suffers from the issue of non-specific adsorption of compounds other than those of interest to the electrode surface, thus affecting the device's output. The aim of this present study was to determine the level of non-specific adsorption on gold electrodes from serum samples with added ovarian cancer biomarker lysophosphatidic acid in the presence of a surface anti-fouling layer. The latter was an oligoethylene molecule with thiol group for attachment to the electrode surface. It was found that the anti-fouling layer had a minimal effect on the level of both adsorption of components from serum and the marker. This result stands in sharp contrast to the analogous monolayer employed for anti-fouling reduction on silica.
Collapse
Affiliation(s)
| | - Michael Thompson
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6, Canada;
| |
Collapse
|
8
|
Yang T, De La Franier B, Thompson M. Anti-Thrombogenicity Study of a Covalently-Attached Monolayer on Stent-Grade Stainless Steel. MATERIALS 2021; 14:ma14092342. [PMID: 33946387 PMCID: PMC8125229 DOI: 10.3390/ma14092342] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 04/21/2021] [Accepted: 04/26/2021] [Indexed: 12/16/2022]
Abstract
Implantable devices fabricated from austenitic type 316L stainless steel have been employed significantly in medicine, principally because the material displays excellent mechanical characteristics and corrosion resistance. It is well known, however, that interaction of exposure of such a material to blood can initiate platelet adhesion and blood coagulation, leading to a harmful medical condition. In order to prevent undesirable surface platelet adhesion on biomaterials employed in procedures such as renal dialysis, we developed an ultrathin anti-thrombogenic covalently attached monolayer based on monoethylene glycol silane chemistry. This functions by forming an interstitial hydration layer which displays restricted mobility in the prevention of surface fouling. In the present work, the promising anti-thrombogenic properties of this film are examined with respect to platelet aggregation on 316L austenitic stainless steel exposed to whole human blood. Prior to exposure with blood, all major surface modification steps were examined by X-ray photoelectron spectroscopic analysis and surface free-angle measurement by contact angle goniometry. End-stage anti-thrombogenicity detection after 20 min of blood exposure at 100 s-1, 300 s-1, 600 s-1, 750 s-1, and 900 s-1 shear rates revealed that a significant reduction (>90%) of platelet adhesion and aggregation was achieved for surface-modified steel, compared with untreated material. This result is confirmed by experiments conducted in real time for 60-minute exposure to blood at 100 s-1, 600 s-1, and 900 s-1 shear rates.
Collapse
|
9
|
Assembling Surface Linker Chemistry with Minimization of Non-Specific Adsorption on Biosensor Materials. MATERIALS 2021; 14:ma14020472. [PMID: 33478142 PMCID: PMC7835736 DOI: 10.3390/ma14020472] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 01/08/2021] [Accepted: 01/13/2021] [Indexed: 01/04/2023]
Abstract
The operation of biosensors requires surfaces that are both highly specific towards the target analyte and that are minimally subject to fouling by species present in a biological fluid. In this work, we further examined the thiosulfonate-based linker in order to construct robust and durable self-assembling monolayers (SAMs) onto hydroxylated surfaces such as silica. These SAMs are capable of the chemoselective immobilization of thiol-containing probes (for analytes) under aqueous conditions in a single, straightforward, reliable, and coupling-free manner. The efficacy of the method was assessed through implementation as a biosensing interface for an ultra-high frequency acoustic wave device dedicated to the detection of avidin via attached biotin. Fouling was assessed via introduction of interfering bovine serum albumin (BSA), IgG antibody, or goat serum. Improvements were investigated systematically through the incorporation of an oligoethylene glycol backbone employed together with a self-assembling diluent without a functional distal group. This work demonstrates that the incorporation of a diluent of relatively short length is crucial for the reduction of fouling. Included in this work is a comparison of the surface attachment of the linker to Si3N4 and AlN, both materials used in sensor technology.
Collapse
|
10
|
De La Franier B, Asker D, van den Berg D, Hatton B, Thompson M. Reduction of microbial adhesion on polyurethane by a sub-nanometer covalently-attached surface modifier. Colloids Surf B Biointerfaces 2021; 200:111579. [PMID: 33517152 DOI: 10.1016/j.colsurfb.2021.111579] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 12/23/2020] [Accepted: 01/11/2021] [Indexed: 01/03/2023]
Abstract
Indwelling urinary catheters are a common medical device used to relieve urinary retention. Many patients who undergo urinary catheterization develop urinary tract infections (UTIs), which can lead to severe medical complications and high cost of subsequent treatment. Recent years have seen a number of attempts at reducing the rate of UTIs in catheterized patients via catheter surface modifications. In this work, a low cost, robust anti-thrombogenic, and sterilizable anti-fouling layer based on a covalently-bound monoethylene glycol hydroxide (MEG-OH) was attached to polyurethane, a polymeric material commonly used to fabricate catheters. Modified polyurethane tubing was compared to bare tubing after exposure to a wide spectrum of pathogens including Gram-negative bacteria (Pesudomonas aeruginosa, Escherichia coli), Gram-positive bacteria (Staphylococcus aureus) and a fungus (Candida albicans). It has been demonstrated that the MEG-OH monolayer was able to significantly reduce the amount of adhesion of pathogens present on the material surface, with between 85 and 96 % reduction after 24 h of exposure. Additionally, similar reductions in surface fouling were observed following autoclave sterilization, long term storage of samples in air, and longer exposure up to 3 days.
Collapse
Affiliation(s)
- Brian De La Franier
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada
| | - Dalal Asker
- Department of Materials Science, University of Toronto, 140-184 College St, Toronto, Ontario, M5S 3E4, Canada; Food Science & Technology Department, Faculty of Agriculture, Alexandria University, 21545 - El-Shatby, Alexandria, Egypt
| | - Desmond van den Berg
- Department of Materials Science, University of Toronto, 140-184 College St, Toronto, Ontario, M5S 3E4, Canada
| | - Benjamin Hatton
- Department of Materials Science, University of Toronto, 140-184 College St, Toronto, Ontario, M5S 3E4, Canada
| | - Michael Thompson
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
| |
Collapse
|
11
|
Cheung D. Effect of surface structure on peptide adsorption on soft surfaces. Chem Phys Lett 2020. [DOI: 10.1016/j.cplett.2020.137929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
12
|
Fungal spore adhesion on glycidoxypropyltrimethoxy silane modified silica nanoparticle surfaces as revealed by single cell force spectroscopy. Biointerphases 2020; 15:031012. [PMID: 32551719 DOI: 10.1116/6.0000142] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Thin film coatings prepared from commercially available glycidoxypropyltrimethoxysilane (GPS) modified silica nanoparticles (SiNPs) (Bindzil® CC301 and Bindzil® CC302) have previously shown excellent antifouling performance against a broad range of microbes [Molino et al., "Hydration layer structure of biofouling-resistant nanoparticles," ACS Nano 12, 11610 (2018)]. In this work, single cell force spectroscopy (SCFS) was used to measure the biological interactions between Epicoccum nigrum fungal spores and the same silica nanoparticle-based surfaces used in the aforementioned study, including a: glass coverslip, unmodified SiNP coatings, and both low (Bindzil® CC301) and high density (CC302) GPS functionalized SiNP coatings as a function of NaCl concentration. From the SCFS curves, the spore adhesion to the surface was greatest on the glass coverslip (20-80 nN) followed by the unmodified SiNP (3-5 nN) across all salt concentrations. Upon approach to both surfaces, the spores showed a long-range attraction generally with a profile characteristic of biointeractions and likely those of the outer cell wall structures or biological constituents. The attractive force allowed the spores to initially adhere to the surface and was found to be linearly proportional to the spore adhesion. In comparison, both high and low density GPS-SINP significantly reduced the spore adhesion (0.5-0.9 nN). In addition, the spore adhesion on high density GPS-SiNP occurred in only 14%-27% of SCFS curves (40%-48% for low density GPS-SiNP) compared to 83%-97% for the unmodified SiNP, indicating that in most cases the GPS functionalization completely prevented spore adhesion. The GPS-SiNP surfaces conversely showed a long-range electrostatic repulsion at low 1mM NaCl that was replaced by short-range repulsion at the higher salt concentrations. From the findings, it is proposed that the attractive force is a critical step in initial adhesion processes of the spore. The effective antifouling properties of the GPS are attributed to the ability to negate the attractive forces, either through electrostatic repulsion in low salt conditions and primarily from short-range repulsion correlating to the previously reported combined steric-hydration effect of the GPS functionalization on SiNP coatings.
Collapse
|
13
|
Penna M, Yarovsky I. Nanoscale in silico classification of ligand functionalised surfaces for protein adsorption resistance. NANOSCALE 2020; 12:7240-7255. [PMID: 32196038 DOI: 10.1039/c9nr10009a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Non-specific protein adsorption represents a significant challenge for the design of efficient and safe nanoparticles for biomedical applications since it may prevent functional ligands to target the desired specific receptors which can limit the efficacy of novel drug delivery systems and biosensors. The biofilm formation initiated by protein adsorption on surfaces limits the lifetime and safety of medical implants and tissue regenerative scaffolds. The development of biofouling resistant surfaces is therefore a major goal for the widespread uptake of nanomedicine. Here, we provide a relatively simple computational screening method based on the rational physically grounded criteria that may suffice in selection of surface grafted ligands for protein rejection, and test whether these criteria can be extrapolated from a specific protein to generic protein-resistant surfaces. Using all-atom molecular dynamics simulations we characterise four types of ligand functionalised surfaces at aqueous interfaces in terms of the surface hydrophobicity and ligand dynamics. We demonstrate how our hypothesised interfacial design based on the select physical characteristics of the ligated surfaces can enable the rejection of a protein from the surface. The ligand screening procedure and the detailed atomistic characterisation of the protein rejection process presented suggest that minimizing the adsorption of surface active proteins requires specific surface topographies and ligand chemistries that are able to maximise the entropic penalty associated with the restriction of the ligand dynamics and trapping interfacial water by adsorbed proteins.
Collapse
Affiliation(s)
- Matthew Penna
- School of Engineering, RMIT University, Melbourne, VIC 3000, Australia.
| | | |
Collapse
|
14
|
Spagnolo S, De La Franier B, Hianik T, Thompson M. Surface Probe Linker with Tandem Anti-Fouling Properties for Application in Biosensor Technology. BIOSENSORS-BASEL 2020; 10:bios10030020. [PMID: 32138172 PMCID: PMC7146171 DOI: 10.3390/bios10030020] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 02/18/2020] [Accepted: 02/26/2020] [Indexed: 12/22/2022]
Abstract
This paper describes the anti-fouling capability of the novel monolayer-forming surface linker 3-(3-(trichlorosilylpropyloxy) propanoyl chloride (MEG-Cl). This compound was successfully attached to quartz crystal surfaces which are employed in an electromagnetic piezoelectric acoustic sensor (EMPAS) configuration. The MEG-Cl coated surface was both employed with Ni-NTA for the binding of recombinant proteins and for the tandem property of the avoidance of fouling from serum and milk. The MEG-Cl coated surfaces were found to provide a large degree of anti-fouling on the EMPAS device, and were comparable to previously studied MEG-OH surfaces. Importantly, the monolayer continued to provide anti-fouling capability to the biosensor following extension with Ni-NTA in place. Accordingly, this surface linker provides an attractive system for use in biosensor technology in terms of both its anti-fouling and linking properties.
Collapse
Affiliation(s)
- Sandro Spagnolo
- Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynská dolina F1, 842 48 Bratislava, Slovakia; (S.S.); (T.H.)
| | - Brian De La Franier
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S, Canada;
| | - Tibor Hianik
- Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynská dolina F1, 842 48 Bratislava, Slovakia; (S.S.); (T.H.)
| | - Michael Thompson
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S, Canada;
- Correspondence: ; Tel.: +1-416-978-3575
| |
Collapse
|
15
|
Mirza KB, Golden CT, Nikolic K, Toumazou C. Closed-Loop Implantable Therapeutic Neuromodulation Systems Based on Neurochemical Monitoring. Front Neurosci 2019; 13:808. [PMID: 31481864 PMCID: PMC6710388 DOI: 10.3389/fnins.2019.00808] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Accepted: 07/19/2019] [Indexed: 12/29/2022] Open
Abstract
Closed-loop or intelligent neuromodulation allows adjustable, personalized neuromodulation which usually incorporates the recording of a biomarker, followed by implementation of an algorithm which decides the timing (when?) and strength (how much?) of stimulation. Closed-loop neuromodulation has been shown to have greater benefits compared to open-loop neuromodulation, particularly for therapeutic applications such as pharmacoresistant epilepsy, movement disorders and potentially for psychological disorders such as depression or drug addiction. However, an important aspect of the technique is selection of an appropriate, preferably neural biomarker. Neurochemical sensing can provide high resolution biomarker monitoring for various neurological disorders as well as offer deeper insight into neurological mechanisms. The chemicals of interest being measured, could be ions such as potassium (K+), sodium (Na+), calcium (Ca2+), chloride (Cl−), hydrogen (H+) or neurotransmitters such as dopamine, serotonin and glutamate. This review focusses on the different building blocks necessary for a neurochemical, closed-loop neuromodulation system including biomarkers, sensors and data processing algorithms. Furthermore, it also highlights the merits and drawbacks of using this biomarker modality.
Collapse
Affiliation(s)
- Khalid B Mirza
- Department of Electrical and Electronic Engineering, Centre for Bio-Inspired Technology, Institute of Biomedical Engineering, Imperial College London, London, United Kingdom
| | - Caroline T Golden
- Department of Electrical and Electronic Engineering, Centre for Bio-Inspired Technology, Institute of Biomedical Engineering, Imperial College London, London, United Kingdom
| | - Konstantin Nikolic
- Department of Electrical and Electronic Engineering, Centre for Bio-Inspired Technology, Institute of Biomedical Engineering, Imperial College London, London, United Kingdom
| | - Christofer Toumazou
- Department of Electrical and Electronic Engineering, Centre for Bio-Inspired Technology, Institute of Biomedical Engineering, Imperial College London, London, United Kingdom
| |
Collapse
|
16
|
Park E, Lee J, Huh KM, Lee SH, Lee H. Toxicity-Attenuated Glycol Chitosan Adhesive Inspired by Mussel Adhesion Mechanisms. Adv Healthc Mater 2019; 8:e1900275. [PMID: 31091015 DOI: 10.1002/adhm.201900275] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2019] [Revised: 04/25/2019] [Indexed: 01/04/2023]
Abstract
Chitosan-catechol, inspired from mussel-adhesive-proteins, is characterized by the formation of an adhesive membrane complex through instant bonding with serum proteins not found in chitosan. Using this intrinsic property, chitosan-catechol is widely applied for hemostatic needles, general hemostatic materials, nanoparticle composites, and 3D printing. Despite its versatility, the practical use of chitosan-catechol in the clinic is limited due to its undesired immune responses. Herein, a catechol-conjugated glycol chitosan is proposed as an alternative hemostatic hydrogel with negligible immune responses enabling the replacement of chitosan-catechol. Comparative cellular toxicity and in vivo skin irritation between chitosan-catechol and glycol chitosan-catechol are evaluated. Their immune responses are also assessed using histological analysis after subcutaneous implantation into mice. The results show that glycol chitosan-catechol significantly attenuates the immune response compared with chitosan-catechol; this finding is likely due to the antibiofouling effect of ethylene glycol groups and the reduced adhesion of immune cells. Finally, the tissue adhesion and hemostatic ability of glycol chitosan-catechol hydrogels reveal that these ethylene glycol groups do not dramatically modify the adhesiveness and hemostatic ability compared with nonglycol chitosan-catechol. This study suggests that glycol chitosan-catechol can be a promising alternative to chitosan-catechol in various biomedical fields such as hemostatic agents.
Collapse
Affiliation(s)
- Eunsook Park
- Department of ChemistryKorea Advanced Institute of Science and Technology (KAIST) 291 University Rd Yuseong‐gu Daejeon 34141 Republic of Korea
| | - Jeehee Lee
- Biomedical Science and Engineering Interdisciplinary ProgramKorea Advanced Institute of Science and Technology (KAIST) 291 University Rd Yuseong‐gu Daejeon 34141 Republic of Korea
| | - Kang Moo Huh
- Department of Polymer Science and EngineeringChungnam National University 99 University Rd Yuseong‐gu Daejeon 34134 Republic of Korea
| | - Soo Hyeon Lee
- Department of ChemistryKorea Advanced Institute of Science and Technology (KAIST) 291 University Rd Yuseong‐gu Daejeon 34141 Republic of Korea
| | - Haeshin Lee
- Department of ChemistryKorea Advanced Institute of Science and Technology (KAIST) 291 University Rd Yuseong‐gu Daejeon 34141 Republic of Korea
| |
Collapse
|
17
|
Franier BDL, Thompson M. Early stage detection and screening of ovarian cancer: A research opportunity and significant challenge for biosensor technology. Biosens Bioelectron 2019; 135:71-81. [DOI: 10.1016/j.bios.2019.03.041] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 03/04/2019] [Accepted: 03/19/2019] [Indexed: 01/15/2023]
|
18
|
Cheung DL, Lau KHA. Atomistic Study of Zwitterionic Peptoid Antifouling Brushes. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:1483-1494. [PMID: 30142978 DOI: 10.1021/acs.langmuir.8b01939] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Using molecular dynamics (MD) simulations, we study the molecular behavior and hydration properties of a set of zwitterionic "peptoid" brushes, grafted on a rutile surface, that has been previously reported to exhibit excellent resistance against protein adsorption and cell attachment. Peptoids are novel poly( N-substituted glycine) peptide mimics with the side chains attached to amide nitrogens. They constitute a unique model polymer system because hundreds of side chains have been demonstrated, and the exact chain length and sequence order of the residues/monomers may be specified in experiments. In this report, we vary the brush grafting density as well as the side chain/polymer molecular volume. We include in our study polysarcosine as an uncharged comparison with a small polymer chain cross-section. Sarcosine is the simplest peptoid residue with only a nominally hydrophobic methyl group as side chain, but is also reported to exhibit high antifouling performance. Overall, we show in detail how molecular volume and hydration effects are intertwined in a zwitterionic polymer brush. For example, the zwitterionic design significantly promotes extended chain conformations and could actually lower the overall electrostatic potential. Some properties promoted by the balanced charges, such as chain flexibility and hydration, increase more prominently at "low" to "intermediate" chain densities. These and other observations should provide insight on the molecular behavior of peptoids and inform the design of zwitterionic antifouling polymer brushes.
Collapse
Affiliation(s)
- David L Cheung
- School of Chemistry , National University of Ireland Galway , Galway H91 TK33 , Ireland
| | - King Hang Aaron Lau
- Department of Pure and Applied Chemistry , University of Strathclyde , Glasgow G1 1XL , United Kingdom
| |
Collapse
|
19
|
Molino PJ, Yang D, Penna M, Miyazawa K, Knowles BR, MacLaughlin S, Fukuma T, Yarovsky I, Higgins MJ. Hydration Layer Structure of Biofouling-Resistant Nanoparticles. ACS NANO 2018; 12:11610-11624. [PMID: 30335960 DOI: 10.1021/acsnano.8b06856] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Hydrophilic surface chemistries can strongly bind water to produce surfaces that are highly resistant to protein adsorption and fouling. The interfacial bound water and its distinct properties have intrigued researchers for decades, yet the relationship between the water three-dimensional structure and function in antifouling coatings remains elusive. Here, we use hydrophilic, epoxy organosilane modified silica nanoparticles to demonstrate cheap, robust, and practically applied coatings that we discover have broad-ranging, ultralow fouling properties when challenged by various proteins, bacteria, and fungal spores. To understand their excellent antifouling properties, frequency modulation-atomic force microscopy is used to directly observe the interfacial water structure at subatomic resolution, which we validate using all-atom molecular dynamic simulations that strikingly predict similar structures of water layers on the original and ultralow fouling surfaces. The convergence of experimental and modeling data reveals that suitably spaced, flexible chains with hydrophilic groups interact with water molecules to produce a connective, quasi-stable layer, consisting of dynamic interfacial water, that provides a basis for antifouling performance of ultrathin, hydrophilic surface chemistries.
Collapse
Affiliation(s)
- Paul J Molino
- ARC Industrial Transformation Research Hub for Australian Steel Manufacturing , Wollongong , NSW 2522 , Australia
- ARC Centre for Electromaterials Science (ACES), Intelligent Polymer Research Institute/AIIM Faculty, Innovation Campus, Squires Way , University of Wollongong , Wollongong , NSW 2522 , Australia
| | - Dan Yang
- ARC Industrial Transformation Research Hub for Australian Steel Manufacturing , Wollongong , NSW 2522 , Australia
- ARC Centre for Electromaterials Science (ACES), Intelligent Polymer Research Institute/AIIM Faculty, Innovation Campus, Squires Way , University of Wollongong , Wollongong , NSW 2522 , Australia
| | - Matthew Penna
- ARC Industrial Transformation Research Hub for Australian Steel Manufacturing , Wollongong , NSW 2522 , Australia
- School of Engineering , RMIT University , Melbourne , Victoria 3001 , Australia
| | - Keisuke Miyazawa
- Division of Electronic Engineering and Computer Science and ∞Nano Life Science Institute (WPI-NanoLSI) , Kanazawa University , Kakuma-machi, Kanazawa 920-1192 , Japan
| | - Brianna R Knowles
- ARC Industrial Transformation Research Hub for Australian Steel Manufacturing , Wollongong , NSW 2522 , Australia
- BlueScope Innovation Laboratories , Old Port Road , Port Kembla , NSW 2505 , Australia
| | - Shane MacLaughlin
- ARC Industrial Transformation Research Hub for Australian Steel Manufacturing , Wollongong , NSW 2522 , Australia
- BlueScope Innovation Laboratories , Old Port Road , Port Kembla , NSW 2505 , Australia
| | - Takeshi Fukuma
- Division of Electronic Engineering and Computer Science and ∞Nano Life Science Institute (WPI-NanoLSI) , Kanazawa University , Kakuma-machi, Kanazawa 920-1192 , Japan
| | - Irene Yarovsky
- ARC Industrial Transformation Research Hub for Australian Steel Manufacturing , Wollongong , NSW 2522 , Australia
- School of Engineering , RMIT University , Melbourne , Victoria 3001 , Australia
| | - Michael J Higgins
- ARC Industrial Transformation Research Hub for Australian Steel Manufacturing , Wollongong , NSW 2522 , Australia
- ARC Centre for Electromaterials Science (ACES), Intelligent Polymer Research Institute/AIIM Faculty, Innovation Campus, Squires Way , University of Wollongong , Wollongong , NSW 2522 , Australia
| |
Collapse
|
20
|
Abstract
Surfaces and interfaces are ubiquitous in nature and are involved in many biological processes. Due to this, natural organisms have evolved a number of methods to control interfacial and surface properties. Many of these methods involve the use of specialised protein biosurfactants, which due to the competing demands of high surface activity, biocompatibility, and low solution aggregation may take structures that differ from the traditional head–tail structure of small molecule surfactants. As well as their biological functions, these proteins have also attracted interest for industrial applications, in areas including food technology, surface modification, and drug delivery. To understand the biological functions and technological applications of protein biosurfactants, it is necessary to have a molecular level description of their behaviour, in particular at surfaces and interfaces, for which molecular simulation is well suited to investigate. In this review, we will give an overview of simulation studies of a number of examples of protein biosurfactants (hydrophobins, surfactin, and ranaspumin). We will also outline some of the key challenges and future directions for molecular simulation in the investigation of protein biosurfactants and how this can help guide future developments.
Collapse
|
21
|
Knowles BR, Wagner P, Maclaughlin S, Higgins MJ, Molino PJ. Silica Nanoparticles Functionalized with Zwitterionic Sulfobetaine Siloxane for Application as a Versatile Antifouling Coating System. ACS APPLIED MATERIALS & INTERFACES 2017; 9:18584-18594. [PMID: 28523917 DOI: 10.1021/acsami.7b04840] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The growing need to develop surfaces able to effectively resist biological fouling has resulted in the widespread investigation of nanomaterials with potential antifouling properties. However, the preparation of effective antifouling coatings is limited by the availability of reactive surface functional groups and our ability to carefully control and organize chemistries at a materials' interface. Here, we present two methods of preparing hydrophilic low-fouling surface coatings through reaction of silica-nanoparticle suspensions and predeposited silica-nanoparticle films with zwitterionic sulfobetaine (SB). Silica-nanoparticle suspensions were functionalized with SB across three pH conditions and deposited as thin films via a simple spin-coating process to generate hydrophilic antifouling coatings. In addition, coatings of predeposited silica nanoparticles were surface functionalized via exposure to zwitterionic solutions. Quartz crystal microgravimetry with dissipation monitoring was employed as a high throughput technique for monitoring and optimizing reaction to the silica-nanoparticle surfaces. Functionalization of nanoparticle films was rapid and could be achieved over a wide pH range and at low zwitterion concentrations. All functionalized particle surfaces presented a high degree of wettability and resulted in large reductions in adsorption of bovine serum albumin protein. Particle coatings also showed a reduction in adhesion of fungal spores (Epicoccum nigrum) and bacteria (Escherichia coli) by up to 87 and 96%, respectively. These results indicate the potential for functionalized nanosilicas to be further developed as versatile fouling-resistant coatings for widespread coating applications.
Collapse
Affiliation(s)
- Brianna R Knowles
- Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, AIIM Facility, Innovation Campus, University of Wollongong , Wollongong, NSW 2522, Australia
- ARC Research Hub for Australian Steel Manufacturing, University of Wollongong , Wollongong, NSW 2522, Australia
- BlueScope Innovation Laboratories , Old Port Road, Port Kembla, NSW 2505, Australia
| | - Pawel Wagner
- Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, AIIM Facility, Innovation Campus, University of Wollongong , Wollongong, NSW 2522, Australia
| | - Shane Maclaughlin
- ARC Research Hub for Australian Steel Manufacturing, University of Wollongong , Wollongong, NSW 2522, Australia
- BlueScope Innovation Laboratories , Old Port Road, Port Kembla, NSW 2505, Australia
| | - Michael J Higgins
- Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, AIIM Facility, Innovation Campus, University of Wollongong , Wollongong, NSW 2522, Australia
- ARC Research Hub for Australian Steel Manufacturing, University of Wollongong , Wollongong, NSW 2522, Australia
| | - Paul J Molino
- Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, AIIM Facility, Innovation Campus, University of Wollongong , Wollongong, NSW 2522, Australia
- ARC Research Hub for Australian Steel Manufacturing, University of Wollongong , Wollongong, NSW 2522, Australia
| |
Collapse
|
22
|
Machado R, Soltani N, Dufour S, Salam MT, Carlen PL, Genov R, Thompson M. Biofouling-Resistant Impedimetric Sensor for Array High-Resolution Extracellular Potassium Monitoring in the Brain. BIOSENSORS 2016; 6:E53. [PMID: 27754393 PMCID: PMC5192373 DOI: 10.3390/bios6040053] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2016] [Revised: 09/28/2016] [Accepted: 09/30/2016] [Indexed: 02/02/2023]
Abstract
Extracellular potassium concentration, [K⁺]o, plays a fundamental role in the physiological functions of the brain. Studies investigating changes in [K⁺]o have predominantly relied upon glass capillary electrodes with K⁺-sensitive solution gradients for their measurements. However, such electrodes are unsuitable for taking spatio-temporal measurements and are limited by the surface area of their tips. We illustrate seizures invoked chemically and in optogenetically modified mice using blue light exposure while impedimetrically measuring the response. A sharp decrease of 1-2 mM in [K⁺]o before each spike has shown new physiological events not witnessed previously when measuring extracellular potassium concentrations during seizures in mice. We propose a novel approach that uses multichannel monolayer coated gold microelectrodes for in vivo spatio-temporal measurements of [K⁺]o in a mouse brain as an improvement to the conventional glass capillary electrode.
Collapse
Affiliation(s)
- Ruben Machado
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6, Canada.
- Toronto Western Research Institute, Fundamental Neurobiology Division, 60 Leonard Avenue, Toronto, ON M5T 2S8, Canada.
| | - Nima Soltani
- Department of Electrical and Computer Engineering, University of Toronto, 10 King's College Road, Toronto, ON M5S 3G4, Canada.
| | - Suzie Dufour
- Toronto Western Research Institute, Fundamental Neurobiology Division, 60 Leonard Avenue, Toronto, ON M5T 2S8, Canada.
| | - Muhammad Tariqus Salam
- Department of Electrical and Computer Engineering, University of Toronto, 10 King's College Road, Toronto, ON M5S 3G4, Canada.
| | - Peter L Carlen
- Toronto Western Research Institute, Fundamental Neurobiology Division, 60 Leonard Avenue, Toronto, ON M5T 2S8, Canada.
- Institute of Biomaterials & Biomedical Engineering, University of Toronto, 164 College Street, Toronto, ON M5S 3G9, Canada.
| | - Roman Genov
- Department of Electrical and Computer Engineering, University of Toronto, 10 King's College Road, Toronto, ON M5S 3G4, Canada.
| | - Michael Thompson
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6, Canada.
- Institute of Biomaterials & Biomedical Engineering, University of Toronto, 164 College Street, Toronto, ON M5S 3G9, Canada.
| |
Collapse
|
23
|
Penna M, Ley K, Maclaughlin S, Yarovsky I. Surface heterogeneity: a friend or foe of protein adsorption – insights from theoretical simulations. Faraday Discuss 2016; 191:435-464. [DOI: 10.1039/c6fd00050a] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
A lack in the detailed understanding of mechanisms through which proteins adsorb or are repelled at various solid/liquid interfaces limits the capacity to rationally design and produce more sophisticated surfaces with controlled protein adsorption in both biomedical and industrial settings. To date there are three main approaches to achieve anti biofouling efficacy, namely chemically adjusting the surface hydrophobicity and introducing various degrees of surface roughness, or a combination of both. More recently, surface nanostructuring has been shown to have an effect on protein adsorption. However, the current resolution of experimental techniques makes it difficult to investigate these three phase systems at the molecular level. In this molecular dynamics study we explore in all-atom detail the adsorption process of one of the most surface active proteins, EAS hydrophobin, known for its versatile ability to self-assemble on both hydrophobic and hydrophilic surfaces forming stable monolayers that facilitate further biofilm growth. We model the adsorption of this protein on organic ligand protected silica surfaces with varying degrees of chemical heterogeneity and roughness, including fully homogenous hydrophobic and hydrophilic surfaces for comparison. We present a detailed characterisation of the functionalised surface structure and dynamics for each of these systems, and the effect the ligands have on interfacial water, the adsorption process and conformational rearrangements of the protein. Results suggest that the ligand arrangement that produces the highest hydrophilic chain mobility and the lack of significant hydrophobic patches shows the most promising anti-fouling efficacy toward hydrophobin. However, the presence on the protein surface of a flexible loop with amphipathic character (the Cys3–Cys4 loop) is seen to facilitate EAS adsorption on all surfaces by enabling the protein to match the surface pattern.
Collapse
Affiliation(s)
- Matthew Penna
- School of Engineering
- RMIT University
- Melbourne
- Australia
- ARC Research Hub for Australian Steel Manufacturing
| | - Kamron Ley
- School of Engineering
- RMIT University
- Melbourne
- Australia
| | - Shane Maclaughlin
- BlueScope Steel Research Laboratories
- Port Kembla
- Australia
- ARC Research Hub for Australian Steel Manufacturing
- Australia
| | - Irene Yarovsky
- School of Engineering
- RMIT University
- Melbourne
- Australia
- ARC Research Hub for Australian Steel Manufacturing
| |
Collapse
|
24
|
Sheikh S, Blaszykowski C, Romaschin A, Thompson M. Endotoxin detection in full blood plasma in a theranostic approach to combat sepsis. RSC Adv 2016. [DOI: 10.1039/c6ra02745h] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A qualitative piezoelectric biosensor assay alternative for the detection of bacterial endotoxin is described to perform measurements in full human blood plasma in a real-time and label-free advanced fashion.
Collapse
Affiliation(s)
- Sonia Sheikh
- Department of Chemistry
- University of Toronto
- Toronto
- Canada M5S 3H6
| | | | | | - Michael Thompson
- Department of Chemistry
- University of Toronto
- Toronto
- Canada M5S 3H6
- Econous Systems Inc
| |
Collapse
|
25
|
Ley KJ, Shaw LA, Yiapanis G, MacLaughlin S, Yarovsky I. Effect of substrate on the responsive behaviour of functionalised surfaces: insights from molecular simulation. MOLECULAR SIMULATION 2015. [DOI: 10.1080/08927022.2015.1083100] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
26
|
Fedorov K, Jankowski A, Sheikh S, Blaszykowski C, Reheman A, Romaschin A, Ni H, Thompson M. Prevention of surface-induced thrombogenesis on poly(vinyl chloride). J Mater Chem B 2015; 3:8623-8628. [PMID: 32262718 DOI: 10.1039/c5tb01582k] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Much biomedical equipment consisting of or containing plastic polymer(s) must come into contact with blood - an interaction that, at the molecular level, may unfortunately prompt biological processes with potentially deleterious, short- or long-term effects such as thrombosis. In the present investigation, this problem is alleviated for poly(vinyl chloride) (PVC) through chemical surface modification with an ultrathin, monoethylene glycol-based coating - a transformation that is characterized using X-ray photoelectron spectroscopy (XPS) supplemented by contact angle goniometry (CAG). Antithrombogenic properties are assessed through calculation (for the first 10 min, and after 60 min) of the surface coverage percentage due to platelet adhesion, aggregation and thrombus formation upon continuous exposure to fluorescently-labelled whole human blood. At all shear rates investigated (300, 900, and 1500 s-1), surface coverage decreases by >99% with respect to bare PVC (10 min, short-term contact with blood). Most importantly, antithrombogenic performance is retained for longer-term exposure experiments (60 min), regardless of applied shear rate as well.
Collapse
Affiliation(s)
- Kiril Fedorov
- Institute of Biomaterials & Biomedical Engineering, University of Toronto, 164 College Street, Toronto, Ontario M5S 3G9, Canada.
| | | | | | | | | | | | | | | |
Collapse
|
27
|
Machado R, Blaszykowski C, Sheikh S, Suganuma Y, Thompson M. Ultrathin Surface Chemistry to Delay Anion Fouling. Chempluschem 2015; 80:911-914. [PMID: 31973268 DOI: 10.1002/cplu.201500027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2015] [Revised: 02/17/2015] [Indexed: 11/07/2022]
Abstract
The unwanted fouling of surfaces by ionic adsorption has received little research attention. In this context, ultrathin organic adlayer surface chemistry-featuring monoethylene glycol based molecular residues-is described that is capable of noticeably decreasing the rate of anion depletion from solution. The strategy is exemplified with glass as the substrate material and fluoride as the anion foulant.
Collapse
Affiliation(s)
- Ruben Machado
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6 (Canada), Fax: (+1) 416 978 8775
| | | | - Sonia Sheikh
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6 (Canada), Fax: (+1) 416 978 8775
| | - Yoshinori Suganuma
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6 (Canada), Fax: (+1) 416 978 8775
| | - Michael Thompson
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6 (Canada), Fax: (+1) 416 978 8775.,Econous Systems Inc. 80 St. George Street, Toronto, ON M5S 3H6 (Canada).,Institute of Biomaterials & Biomedical Engineering, University of Toronto, 164 College Street, Toronto, ON M5S 3G9 (Canada)
| |
Collapse
|
28
|
Blaszykowski C, Sheikh S, Thompson M. A survey of state-of-the-art surface chemistries to minimize fouling from human and animal biofluids. Biomater Sci 2015. [DOI: 10.1039/c5bm00085h] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Fouling of artificial surfaces by biofluids is a plague Biotechnology deeply suffers from. Herein, we inventory the state-of-the-art surface chemistries developed to minimize this effect from both human and animal biosamples.
Collapse
Affiliation(s)
| | - Sonia Sheikh
- University of Toronto
- Department of Chemistry – St. George campus
- Toronto
- Canada M5S 3H6
| | - Michael Thompson
- Econous Systems Inc
- Toronto
- Canada M5S 3H6
- University of Toronto
- Department of Chemistry – St. George campus
| |
Collapse
|