1
|
Pham HN, Pham PNH, Phan HT, Cao LT, Thoi HTT, Do TDT, Truong TTA. Impact of hematocrit levels on the accuracy of specific blood glucose meters: A hospital-based study. J Diabetes Investig 2024; 15:1472-1482. [PMID: 39087885 PMCID: PMC11442750 DOI: 10.1111/jdi.14276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2024] [Revised: 07/10/2024] [Accepted: 07/17/2024] [Indexed: 08/02/2024] Open
Abstract
AIMS/INTRODUCTION Blood glucose meters are commonly used at the bedside, but most of the meters used in Hung Vuong Hospital (Ho Chi Minh City, Vietnam) are built for self-monitoring and might not be suitable for determining glucose levels in patients. In this study, we aimed to validate the performance of six frequently used meters in our hospital using the Clinical & Laboratory Standards Institute (CLSI) standard, and investigate the hematocrit impact on the accuracy of these meters. MATERIALS AND METHODS A total of 135 pregnant women who underwent a 75-g oral glucose tolerance test consented to participate in the study at Hung Vuong Hospital. Whole blood glucose levels were measured in duplicate using meters, and hematocrit levels were measured using an Alinity h-series analyzer. Within 5 min, plasma glucose levels were measured twice in a row using the Cobas c502 reference analyzer. For accuracy and precision, the hematocrit effect was assed using CLSI POCT12-A3. RESULTS Out of six evaluated meters, three meters qualified. For CLSI criterion at glucose concentration of 5.55 mmol/L, Accu-Chek Inform II, Accu-Chek Performa and OneTouch VerioVue achieved 97.31%, 98.08% and 99.62%, respectively. For CLSI criterion at 4.17 mmol/L, these three achieved 100%. Accu-Chek Inform II and Accu-Chek Performa showed an inverse correlation between glucose level and hematocrit with slopes of -0.500 (95% confidence interval -0.678 to -0.322) and -0.396 (95% confidence interval -0.569 to -0.224), whereas OneTouch VerioVue was not affected by hematocrit, with a slope of 0.207 (95% confidence interval -0.026 to 0.440). CONCLUSIONS Blood glucose meters' measurements can be affected by hematocrit, and might provide readings not within an acceptable bias. Medical organizations need to verify or validate before using on patients.
Collapse
|
2
|
Bayat S, Perumal-Pillay VA, Suleman F. Availability and pricing of insulin and related diagnostics in South Africa. J Pharm Policy Pract 2024; 17:2372467. [PMID: 39015751 PMCID: PMC11251433 DOI: 10.1080/20523211.2024.2372467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Accepted: 06/10/2024] [Indexed: 07/18/2024] Open
Abstract
Background In South Africa (SA), most patients rely on the government for free healthcare. Some choose to subscribe to a medical insurance scheme. If insulin is unavailable in government or otherwise unaffordable, non-adherence may occur, which can increase complications of the disease. Methods Data on availability and pricing of insulin and related diagnostics was collected from SA pharmacies via an online survey. Co-payments levied on insulin by the biggest medical aids were extracted from formularies. Affordability of these items was then assessed. An adapted methodology from the World Health Organization/Health Action International tool was used. Results There was fairly high availability of insulin in the public sector, with the exception of long-acting insulin which respondents claimed was difficult to find; however, long-acting insulin glargine was available in most private sector pharmacies. Point-of-care (POC) blood glucose testing was free in the public sector but offered in only 31.25% of pharmacies. Patients pay a minimum of USD 40.4 (over 3 days' wages for the lowest paid government worker (LPGW)) for a months' supply of the cheapest insulin, needles and test strips. Insulin in SA was cheaper than 5 other countries, except Australia. Conclusion Overall, there is a good availability of insulin and related diagnostics in SA. Even though insulin is cheaper than other countries, it is unaffordable to the LPGW. This highlights the importance of ensuring a constant availability of insulin in the free public sector. Whilst human insulins are cheaper than newer analogue insulins and SA faces cost constraints, important variables in favour of newer insulins, such as ease-of-use, long term outcomes and value should be considered when treatment guidelines are updated. Annual POC testing should be available and offered free to all patients to detect diabetes early.
Collapse
Affiliation(s)
- Samirah Bayat
- Discipline of Pharmaceutical Sciences, University of KwaZulu-Natal, Durban, South Africa
| | | | - Fatima Suleman
- School of Health Sciences, University of KwaZulu-Natal, Durban, South Africa
| |
Collapse
|
3
|
Norris SA, Zarowsky C, Murphy K, Ware LJ, Lombard C, Matjila M, Chivese T, Muhwava LS, Mutabazi JC, Harbron J, Fairall LR, Lambert E, Levitt N. Integrated health system intervention aimed at reducing type 2 diabetes risk in women after gestational diabetes in South Africa (IINDIAGO): a randomised controlled trial protocol. BMJ Open 2024; 14:e073316. [PMID: 38195169 PMCID: PMC10806811 DOI: 10.1136/bmjopen-2023-073316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Accepted: 11/27/2023] [Indexed: 01/11/2024] Open
Abstract
INTRODUCTION South Africa has a high prevalence of gestational diabetes mellitus (GDM; 15%) and many of these women (48%) progress to type 2 diabetes mellitus (T2DM) within 5 years post partum. A significant proportion (47%) of the women are not aware of their diabetes status after the index pregnancy, which may be in part to low postnatal diabetes screening rates. Therefore, we aim to evaluate a intervention that reduces the subsequent risk of developing T2DM among women with recent GDM. Our objectives are fourfold: (1) compare the completion of the nationally recommended 6-week postpartum oral glucose tolerance test (OGTT) between intervention and control groups; (2) compare the diabetes risk reduction between control and intervention groups at 12 months' post partum; (3) assess the process of implementation; and (4) assess the cost-effectiveness of the proposed intervention package. METHODS AND ANALYSES Convergent parallel mixed-methods study with the main component being a pragmatic, 2-arm individually randomised controlled trial, which will be carried out at five major referral centres and up to 26 well-baby clinics in the Western Cape and Gauteng provinces of South Africa. Participants (n=370) with GDM (with no prior history of either type 1 or type 2 diabetes) will be recruited into the study at 24-36 weeks' gestational age, at which stage first data collection will take place. Subsequent data collection will take place at 6-8 weeks after delivery and again at 12 months. The primary outcome for the trial is twofold: first, the completion of the recommended 2-hour OGTT at the well-baby clinics 6-8 weeks post partum, and second, a composite diabetes risk reduction indicator at 12 months. Process evaluation will assess fidelity, acceptability, and dose of the intervention. ETHICS AND DISSEMINATION Ethics approval has been granted from University of Cape Town (829/2016), University of the Witwatersrand, Johannesburg (M170228), University of Stellenbosch (N17/04/032) and the University of Montreal (2019-794). The results of the trial will be disseminated through publication in peer-reviewed journals and presentations to key South African Government stakeholders and health service providers. PROTOCOL VERSION 1 December 2022 (version #2). Any protocol amendments will be communicated to investigators, Human Ethics Research Committees, trial participants, and trial registries. TRIAL REGISTRATION NUMBER PAN African Clinical Trials Registry (https://pactr.samrc.ac.za) on 11 June 2018 (identifier PACTR201805003336174).
Collapse
Affiliation(s)
- Shane A Norris
- SAMRC Developmental Pathways for Health Research Unit, Paediatrics and Child Health, University of the Witwatersrand, Johannesburg, South Africa
| | - Christina Zarowsky
- School of Public Health, University of Montreal, Montreal, Québec, Canada
| | - Katherine Murphy
- Faculty of Health Science, Department of Medicine, University of Cape Town, Rondebosch, South Africa
| | - Lisa Jayne Ware
- SAMRC Developmental Pathways for Health Research Unit, Paediatrics and Child Health, University of the Witwatersrand, Johannesburg, South Africa
- Faculty of Health Sciences, DSI-NRF Centre of Excellence in Human Development, University of the Witwatersrand Johannesburg, Johannesburg, South Africa
| | - Carl Lombard
- Biostatistics Unit, South African Medical Research Council, Tygerberg, South Africa
| | - Mushi Matjila
- Department of Obstetrics and Gynaecology, University of Cape Town, Cape Town, South Africa
| | - Tawanda Chivese
- Department of Population Medicine, College of Medicine, QU Health, Qatar University, Doha, Qatar
| | | | - Jean Claude Mutabazi
- Médecine sociale et préventive-Option: Santé Mondiale, University of Montreal, Montreal, Québec, Canada
| | | | | | | | - Naomi Levitt
- Department of Medicine, University of Cape Town, Rondebosch, South Africa
| |
Collapse
|
4
|
Accuracy of capillary blood glucose for 50-g glucose challenge test for gestational diabetes screening. Diabetol Int 2022; 13:561-565. [PMID: 35693996 PMCID: PMC9174389 DOI: 10.1007/s13340-022-00572-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Accepted: 01/17/2022] [Indexed: 10/19/2022]
Abstract
Purpose To assess the accuracy of capillary blood glucose (CBG) compared to conventional venous plasma glucose (VPG) testing for 50-g glucose challenge test (GCT) in gestational diabetes (GDM) screening. Methods A total of 300 women were enrolled and 50-g GCT for GDM screening was offered. At 1 h after glucose loading, CBG was evaluated by CONTOUR® PLUS glucose meter by well-trained nurses immediately after venipuncture for VPG. Results of CBG were compared with those from VPG to evaluate its accuracy. Women with venous plasma glucose > 140 mg/dL were offered 100-g OGTT for GDM diagnosis. Results The mean age was 30.2 years and the mean gestational age at testing was 21.8 weeks. GDM was diagnosed in 34 women (11.3%). The mean VPG was 142.1 ± 32.9 mg/dL and the mean CBG was 129.3 ± 33.5 mg/dL. Mean difference was -12.3 ± 12.5 mg/dL, corresponding to -8.8 ± 11.4%. CBG significantly correlated with VPG with correlation coefficient of 0.929, p < 0.001. In the detection of abnormal 50-g GCT results (VPG ≥ 140 mg/dL), at 126 mg/dL cutoff, CBG had sensitivity of 92.5%, specificity of 81.8%, and positive and negative predictive values of 82.8%and 92%. None of the GDM would have been missed if CBG was used. Conclusion CBG by a certified glucose meter could be considered as an alternative to conventional VPG testing for 50-g GCT for GDM screening using 126 mg/dL cutoff value.
Collapse
|
5
|
Pirdehghan A, Eslahchi M, Esna-Ashari F, Borzouei S. Health literacy and diabetes control in pregnant women. J Family Med Prim Care 2020; 9:1048-1052. [PMID: 32318465 PMCID: PMC7114019 DOI: 10.4103/jfmpc.jfmpc_891_19] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 12/23/2019] [Accepted: 12/31/2019] [Indexed: 12/21/2022] Open
Abstract
Background: Low health literacy (HL) is associated with an extensive range of health outcomes. Objective: The present study was performed to inquire about the relationship between HL and glycemic control in gestational diabetes in order to design interventional future preventing programs. Methods: This cross-sectional study was performed on 104 Iranian pregnant women with gestational diabetes mellitus (GDM) referred from urban and rural areas to endocrinology clinic of Hamadan Beheshti Hospital, in 2017. Iranian Health Literacy Questionnaire (IHLQ) and a sociodemographic checklist were distributed among women. Correlation between HL and glycemic control was examined using SPSS. The significance level was set at P < 0.05. Results: Among women, 48.1% (50) were affected by uncontrolled diabetes and only 22% (11) had an adequate level of HL. An adequate level of HL were 50% and 22% in glycemic controlled and uncontrolled women, respectively. In univariate analysis, there was a significant relationship between diabetes control and adequate HL. So, problematic HL could increase the chance of uncontrolled diabetes more than three times (odds ratio: 3.5; CI: 1.5–8.3; P value: 0.004). Among all related variables, education and being housewife were considered as protective and risk factors for problematic HL, respectively. Conclusion: In conclusion, this study has provided evidence of limited HL and its relationship with low glycemic control in pregnant women with GDM. The problem was more serious in low educated, rural, housekeepers, and older-aged women. This deficit needs to be addressed by health planners and policymakers who are responsible for promoting the health of people and decreasing health inequalities community.
Collapse
Affiliation(s)
- Azar Pirdehghan
- Department of Community and Preventive Medicine, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Mohammad Eslahchi
- Medical Student, School of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Farzaneh Esna-Ashari
- Department of Community and Preventive Medicine, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Shiva Borzouei
- Department of Internal Medicine, School of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
6
|
Gygliola-Ormachea PB, Tarquino-Flores G, Chambi-Gutierrez E, Averanga-Conde K, Salcedo-Ortiz L. Determinación de glucosa. JOURNAL OF THE SELVA ANDINA RESEARCH SOCIETY 2020. [DOI: 10.36610/j.jsars.2020.110100038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
7
|
Dickson LM, Buchmann EJ, Janse Van Rensburg C, Norris SA. The impact of differences in plasma glucose between glucose oxidase and hexokinase methods on estimated gestational diabetes mellitus prevalence. Sci Rep 2019; 9:7238. [PMID: 31076622 PMCID: PMC6510785 DOI: 10.1038/s41598-019-43665-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Accepted: 04/23/2019] [Indexed: 12/20/2022] Open
Abstract
We evaluated the extent of measurement discordance between glucose oxidase and hexokinase laboratory methods and the effect of this on estimated gestational diabetes mellitus (GDM) prevalence in a routine clinical setting. 592 consecutive urban African women were screened for GDM. Paired venous specimens were submitted to two independent calibrated laboratories that used either method to measure plasma glucose concentrations. World Health Organisation diagnostic criteria were applied. GDM prevalence determined by the glucose oxidase and hexokinase methods was 6.9% and 5.1% respectively. The overall GDM prevalence was 9%. Only 34% of GDM positive diagnoses were common to both laboratory methods. Bland Altman plots identified a bias of 0.2 mmol/l between laboratory methods. Plasma glucose concentrations measured by the glucose oxidase method were more platykurtic in distribution. Low diagnostic agreement between laboratory methods was further indicated by a Cohen's kappa of 0.48 (p < 0.001). Reports of GDM prevalence using either the glucose oxidase or hexokinase laboratory methods may not be truly interchangeable or directly comparable.
Collapse
Affiliation(s)
- Lynnsay M Dickson
- MRC Developmental Pathways to Health Research Unit, Department of Paediatrics, Faculty of Health Sciences, University of the Witwatersrand, York Road, Parktown, Johannesburg, South Africa.
| | - Eckhart J Buchmann
- Department of Obstetrics and Gynaecology, Faculty of Health Sciences, University of the Witwatersrand, York Road, Parktown, Johannesburg, South Africa
| | - Charl Janse Van Rensburg
- Biostatistics Unit, South African Medical Research Council, 1 Soutpansberg Road, Pretoria, South Africa
| | - Shane A Norris
- MRC Developmental Pathways to Health Research Unit, Department of Paediatrics, Faculty of Health Sciences, University of the Witwatersrand, York Road, Parktown, Johannesburg, South Africa
| |
Collapse
|