1
|
Govindaraj M, Srivastava A, Muthukumaran MK, Tsai PC, Lin YC, Raja BK, Rajendran J, Ponnusamy VK, Arockia Selvi J. Current advancements and prospects of enzymatic and non-enzymatic electrochemical glucose sensors. Int J Biol Macromol 2023; 253:126680. [PMID: 37673151 DOI: 10.1016/j.ijbiomac.2023.126680] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/19/2023] [Accepted: 09/01/2023] [Indexed: 09/08/2023]
Abstract
This review discusses the most current developments and future perspectives in enzymatic and non-enzymatic glucose sensors, which have notably evolved over the preceding quadrennial period. Furthermore, a thorough exploration encompassed the sensor's intricate fabrication processes, the diverse range of materials employed, the underlying principles of detection, and an in-depth assessment of the sensors' efficacy in detecting glucose levels within essential bodily fluids such as human blood serums, urine, saliva, and interstitial fluids. It is worth noting that the accurate quantification of glucose concentrations within human blood has been effectively achieved by utilizing classical enzymatic sensors harmoniously integrated with optical and electrochemical transduction mechanisms. Monitoring glucose levels in various mediums has attracted exceptional attention from industrial to academic researchers for diabetes management, food quality control, clinical medicine, and bioprocess inspection. There has been an enormous demand for the creation of novel glucose sensors over the past ten years. Research has primarily concentrated on succeeding biocompatible and enhanced sensing abilities related to the present technologies, offering innovative avenues for more effective glucose sensors. Recent developments in wearable optical and electrochemical sensors with low cost, high stability, point-of-care testing, and online tracking of glucose concentration levels in biological fluids can aid in managing and controlling diabetes globally. New nanomaterials and biomolecules that can be used in electrochemical sensor systems to identify glucose concentration levels are developed thanks to advances in nanoscience and nanotechnology. Both enzymatic and non-enzymatic glucose electrochemical sensors have garnered much interest recently and have made significant strides in detecting glucose levels. In this review, we summarise several categories of non-enzymatic glucose sensor materials, including composites, non-precious transition metals and their metal oxides, hydroxides, precious metals and their alloys, carbon-based materials, conducting polymers, metal-organic framework (MOF)-based electrocatalysts, and wearable device-based glucose sensors deeply.
Collapse
Affiliation(s)
- Muthukumar Govindaraj
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India; Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan
| | - Ananya Srivastava
- Department of Chemistry, Institute of Science, Banaras Hindu University, Varanasi 221005, India
| | - Magesh Kumar Muthukumaran
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
| | - Pei-Chien Tsai
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Department of Computational Biology, Institute of Bioinformatics, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Chennai, Tamil Nadu, 602105, India
| | - Yuan-Chung Lin
- Institute of Environmental Engineering, National Sun Yat-sen University, Kaohsiung 804, Taiwan; Center for Emerging Contaminants Research, National Sun Yat-sen University, Kaohsiung 804, Taiwan.
| | - Bharathi Kannan Raja
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
| | - Jerome Rajendran
- Department of Electrical Engineering and Computer Science, The University of California, Irvine, CA 92697, United States
| | - Vinoth Kumar Ponnusamy
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Center for Emerging Contaminants Research, National Sun Yat-sen University, Kaohsiung 804, Taiwan; Research Center for Precision Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Department of Medical Research, Kaohsiung Medical University Hospital (KMUH), Kaohsiung Medical University, Kaohsiung City 807, Taiwan; Department of Chemistry, National Sun Yat-sen University (NSYSU), Kaohsiung City 804, Taiwan.
| | - J Arockia Selvi
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India.
| |
Collapse
|
2
|
Kim SE, Yoon JC, Tae HJ, Muthurasu A. Electrospun Manganese-Based Metal-Organic Frameworks for MnO x Nanostructures Embedded in Carbon Nanofibers as a High-Performance Nonenzymatic Glucose Sensor. ACS OMEGA 2023; 8:42689-42698. [PMID: 38024713 PMCID: PMC10652823 DOI: 10.1021/acsomega.3c05459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 10/15/2023] [Accepted: 10/17/2023] [Indexed: 12/01/2023]
Abstract
Material-specific electrocatalytic activity and electrode design are essential factors in evaluating the performance of electrochemical sensors. Herein, the technique described involves electrospinning manganese-based metal-organic frameworks (Mn-MOFs) to develop MnOx nanostructures embedded in carbon nanofibers. The resulting structure features an electrocatalytic material for an enzyme-free glucose sensor. The elemental composition, morphology, and microstructure of the fabricated electrodes materials were characterized by using energy-dispersive X-ray spectroscopy (EDX), field-emission scanning electron microscopy (FESEM), and transmission electron microscopy (TEM). Cyclic voltammetry (CV) and amperometric i-t (current-time) techniques are characteristically employed to assess the electrochemical performance of materials. The MOF MnOx-CNFs nanostructures significantly improve detection performance for nonenzymatic amperometric glucose sensors, including a broad linear range (0 mM to 9.1 mM), high sensitivity (4080.6 μA mM-1 cm-2), a low detection limit (0.3 μM, S/N = 3), acceptable selectivity, outstanding reproducibility, and stability. The strategy of metal and metal oxide-integrated CNF nanostructures based on MOFs opens interesting possibilities for the development of high-performance electrochemical sensors.
Collapse
Affiliation(s)
- So Eun Kim
- Department
of Emergency Medicine, Research Institute
of Clinical Medicine of Jeonbuk National University and Biomedical
Research Institute of Jeonbuk National University Hospital, Jeonju 54907, Republic of Korea
| | - Jae Chol Yoon
- Department
of Emergency Medicine, Research Institute
of Clinical Medicine of Jeonbuk National University and Biomedical
Research Institute of Jeonbuk National University Hospital, Jeonju 54907, Republic of Korea
| | - Hyun-Jin Tae
- College
of Veterinary Medicine and Biosafety Research Institute, Jeonbuk National University, Iksan 54596, Republic of Korea
| | - Alagan Muthurasu
- Department
of Nano Convergence Technology, Jeonbuk
National University, Jeonju 54907, Republic
of Korea
| |
Collapse
|
3
|
Jiang M, Liao J, Liu C, Liu J, Chen P, Zhou J, Du Z, Liu Y, Luo Y, Liu Y, Chen F, Fang X, Lin X. Metal-organic frameworks/metal nanoparticles as smart nanosensing interfaces for electrochemical sensors applications: a mini-review. Front Bioeng Biotechnol 2023; 11:1251713. [PMID: 37614634 PMCID: PMC10442806 DOI: 10.3389/fbioe.2023.1251713] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Accepted: 07/28/2023] [Indexed: 08/25/2023] Open
Abstract
Metal-organic frameworks (MOFs) are porous materials with huge specific surface area and abundant active sites, which are composed of metal ions or clusters and organic ligands in the form of coordination bonds. In recent years, MOFs have been successfully applied in many fields due to their excellent physical, chemical, and biological properties. Electrochemical sensors have advantages such as economy, portability, and sensitivity, making them increasingly valued in the field of sensors. Many studies have shown that the electrode materials will affect the performance of electrochemical sensors. Therefore, the research on electrode materials is still one of the hotspots. MOFs are also commonly used to construct electrochemical sensors. However, electrochemical sensors prepared from single MOFs have shortcomings such as insufficient conductivity, low sensitivity, and poor electrochemical catalytic ability. In order to compensate for these defects, a new type of nanocomposite material with very ideal conductivity was formed by adding metal nanoparticles (MNPs) to MOFs. The combination of the two is expected to be widely applied in the field of sensors. This review summarizes the applications of various MNPs/MOFs composites in the field of electrochemical sensors and provides some references for the development of MNPs/MOFs composites-based electrochemical sensors in the future.
Collapse
Affiliation(s)
- Min Jiang
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou, China
| | - Jing Liao
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou, China
| | - Chenghao Liu
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou, China
| | - Jun Liu
- Department of Neurosurgery, The Second Affifiliated Hospital of Nanchang University, Nanchang, China
- Department of Neurosurgery, The Affiliated Ganzhou Hospital of Nanchang University, Ganzhou, China
| | - Peixian Chen
- Department of Health Services, Fujian Hwa Nan Women’s College, Fuzhou, China
| | - Jia Zhou
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou, China
| | - Zhizhi Du
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou, China
| | - Yan Liu
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou, China
| | - Yan Luo
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou, China
| | - Yangbin Liu
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou, China
| | - Fei Chen
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou, China
| | - Xiaojun Fang
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou, China
| | - Xiaofeng Lin
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases of Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Medical and Information Engineering, School of Pharmacy, Scientific Research Center, Gannan Medical University, Ganzhou, China
| |
Collapse
|
4
|
Li Z, Zeng W, Li Y. Recent Progress in MOF-Based Electrochemical Sensors for Non-Enzymatic Glucose Detection. Molecules 2023; 28:4891. [PMID: 37446552 DOI: 10.3390/molecules28134891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Revised: 06/12/2023] [Accepted: 06/15/2023] [Indexed: 07/15/2023] Open
Abstract
In recent years, substantial advancements have been made in the development of enzyme-free glucose sensors utilizing pristine metal-organic frameworks (MOFs) and their combinations. This paper provides a comprehensive exploration of various MOF-based glucose sensors, encompassing monometallic MOF sensors as well as multi-metal MOF combinations. These approaches demonstrate improved glucose detection capabilities, facilitated by the augmented surface area and availability of active sites within the MOF structures. Furthermore, the paper delves into the application of MOF complexes and derivatives in enzyme-free glucose sensing. Derivatives incorporating carbon or metal components, such as carbon cloth synthesis, rGO-MOF composites, and core-shell structures incorporating noble metals, exhibit enhanced electrochemical performance. Additionally, the integration of MOFs with foams or biomolecules, such as porphyrins, enhances the electrocatalytic properties for glucose detection. Finally, this paper concludes with an outlook on the future development prospects of enzyme-free glucose MOF sensors.
Collapse
Affiliation(s)
- Ziteng Li
- College of Materials Science and Engineering, Chongqing University, Chongqing 400030, China
| | - Wen Zeng
- College of Materials Science and Engineering, Chongqing University, Chongqing 400030, China
| | - Yanqiong Li
- School of Electronic Information & Electrical Engineering, Chongqing University of Arts and Sciences, Chongqing 400030, China
| |
Collapse
|
5
|
Sabir AS, Pervaiz E, Khosa R, Sohail U. An inclusive review and perspective on Cu-based materials for electrochemical water splitting. RSC Adv 2023; 13:4963-4993. [PMID: 36793292 PMCID: PMC9924225 DOI: 10.1039/d2ra07901a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Accepted: 01/25/2023] [Indexed: 02/15/2023] Open
Abstract
In recent years, there has been a resurgence of interest in developing green and renewable alternate energy sources as a solution to the energy and environmental problems produced by conventional fossil fuel use. As a very effective energy transporter, hydrogen (H2) is a possible candidate for the future energy supply. Hydrogen production by water splitting is a promising new energy option. Strong, efficient, and abundant catalysts are required for increasing the efficiency of the water splitting process. Cu-based materials as an electrocatalyst have shown promising results for application in the Hydrogen Evolution Reaction (HER) and Oxygen Evolution Reaction (OER) in water splitting. In this review, our aim is to cover the latest developments in the synthesis, characterisation, and electrochemical behaviour of Cu-based materials as a HER, and OER electrocatalyst, highlighting the impact that these advances have had on the field. It is intended that this review article will serve as a roadmap for developing novel, cost-effective electrocatalysts for electrochemical water splitting based on nanostructured materials with particular emphasis on Cu-based materials for electrocatalytic water splitting.
Collapse
Affiliation(s)
- Abdul Shakoor Sabir
- Heterogeneous Catalysis Lab, Department of Chemical Engineering, School of Chemical and Materials Engineering (SCME), National University of Sciences and Technology (NUST) Islamabad 44000 Pakistan
| | - Erum Pervaiz
- Heterogeneous Catalysis Lab, Department of Chemical Engineering, School of Chemical and Materials Engineering (SCME), National University of Sciences and Technology (NUST) Islamabad 44000 Pakistan
| | - Rafiq Khosa
- Heterogeneous Catalysis Lab, Department of Chemical Engineering, School of Chemical and Materials Engineering (SCME), National University of Sciences and Technology (NUST) Islamabad 44000 Pakistan
| | - Umair Sohail
- Heterogeneous Catalysis Lab, Department of Chemical Engineering, School of Chemical and Materials Engineering (SCME), National University of Sciences and Technology (NUST) Islamabad 44000 Pakistan
| |
Collapse
|
6
|
Li M, Huan K, Deng D, Yan X, Li Y, Luo L. Coaxial electrospinning synthesis of size-tunable CuO/NiO hollow heterostructured nanofibers: Towards detection of glucose level in human serum. Colloids Surf B Biointerfaces 2023; 222:113047. [PMID: 36463609 DOI: 10.1016/j.colsurfb.2022.113047] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 11/09/2022] [Accepted: 11/20/2022] [Indexed: 11/23/2022]
Abstract
Nanofibers (NFs) have found wide applications by virtue of their particular morphology and high specific surface area. In this study, size-tunable hollow CuO/NiO NFs were synthesized by coaxial electrospinning and subsequent calcination. The synthesized hollow CuO/NiO NFs owned large specific surface area for catalytic active sites. In addition, the formation of heterostructure interface between CuO and NiO was beneficial to improve the electrocatalytic performance. As non-enzymatic electrode material, the synthesized CuO/NiO NFs exhibited superior electrocatalytic capability for glucose oxidation. When the molar ratio of CuO to NiO is 0.4, the composite NFs achieved the optimal electrocatalytic ability for glucose oxidation, performing high sensitivity of 1324.17 μA mM-1 cm-2 and wide liner range from 1 to 10,000 μM. The constructed electrode has been utilized to detect glucose concentration in real serum with excellent recovery, indicating that CuO/NiO hollow heterostructured NFs are promising materials for biomedical applications.
Collapse
Affiliation(s)
- Mengjie Li
- Department of Physics, Shanghai Key Laboratory of High Temperature Superconductors, Shanghai University, Shanghai 200444, PR China
| | - Ke Huan
- Department of Physics, Shanghai Key Laboratory of High Temperature Superconductors, Shanghai University, Shanghai 200444, PR China
| | - Dongmei Deng
- Department of Physics, Shanghai Key Laboratory of High Temperature Superconductors, Shanghai University, Shanghai 200444, PR China.
| | - Xiaoxia Yan
- Department of Chemistry, Shanghai University, Shanghai 200444, PR China
| | - Yuanyuan Li
- Department of Physics, Shanghai Key Laboratory of High Temperature Superconductors, Shanghai University, Shanghai 200444, PR China
| | - Liqiang Luo
- Department of Chemistry, Shanghai University, Shanghai 200444, PR China.
| |
Collapse
|
7
|
Non-Noble-Metal Mono and Bimetallic Composites for Efficient Electrocatalysis of Phosphine Oxide and Acetylene C-H/P-H Coupling under Mild Conditions. Int J Mol Sci 2023; 24:ijms24010765. [PMID: 36614210 PMCID: PMC9821134 DOI: 10.3390/ijms24010765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 12/28/2022] [Accepted: 12/29/2022] [Indexed: 01/03/2023] Open
Abstract
The present work describes an efficient reaction of electrochemical phosphorylation of phenylacetylene controlled by the composition of catalytic nanoparticles based on non-noble-metals. The sought-after products are produced via the simple synthetic protocol based on room temperature, atom-economical reactions, and silica nanoparticles (SNs) loaded by one or two d-metal ions as nanocatalysts. The redox and catalytic properties of SNs can be tuned with a range of parameters, such as compositions of the bimetallic systems, their preparation method, and morphology. Monometallic SNs give phosphorylated acetylene with retention of the triple bond, and bimetallic SNs give a bis-phosphorylation product. This is the first example of acetylene and phosphine oxide C-H/P-H coupling with a regenerable and recyclable catalyst.
Collapse
|
8
|
Kurbanoglu S, Cevher SC, Toppare L, Cirpan A, Soylemez S. Electrochemical biosensor based on three components random conjugated polymer with fullerene (C 60). Bioelectrochemistry 2022; 147:108219. [PMID: 35933973 DOI: 10.1016/j.bioelechem.2022.108219] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 07/27/2022] [Accepted: 07/28/2022] [Indexed: 11/16/2022]
Abstract
Herein, a conjugated polymer and fullerene bearing architecture-based electrochemical Tyrosinase (Tyr) enzyme inhibition biosensor for indomethacin (INDO) drug active compound has been developed. For this purpose, three moieties of benzoxadiazole, thienopyrroledione, and benzodithiophene containing conjugated polymer; poly[BDT-alt-(TP;BO)] was used as a transducer modifier together with fullerene for catechol detection. The specific combination of these materials is considered an effective way to fabricate highly sensitive and fast response catechol biosensors for the first time. Electrochemical and surface characteristics of the modified electrodes were obtained by cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy, and atomic force microscopy. The effect of the parameters during chronoamperometric measurements on the biosensor response was also studied. Using optimized conditions, biosensing of catechol was achieved between 0.5 and 62.5 µM with a limit of the detection 0.11 µM. Tyr inhibition was followed with INDO drug active compound and it was found that INDO has a mixed type characteristic of enzyme kinetics with an I50 value of 15.11 µM.
Collapse
Affiliation(s)
- Sevinc Kurbanoglu
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560 Ankara, Turkey
| | - Sevki Can Cevher
- Department of Engineering Fundamental Sciences, Sivas University of Science and Technology, 58100 Sivas, Turkey
| | - Levent Toppare
- Department of Chemistry, Middle East Technical University, Ankara 06800, Turkey; Department of Polymer Science and Technology, Middle East Technical University, Ankara 06800, Turkey; Department of Biotechnology, Middle East Technical University, Ankara 06800, Turkey
| | - Ali Cirpan
- Department of Chemistry, Middle East Technical University, Ankara 06800, Turkey; Department of Polymer Science and Technology, Middle East Technical University, Ankara 06800, Turkey; The Center for Solar Energy Research and Application (GUNAM), Middle East Technical University, Ankara 06800, Turkey; Department of Micro and Nanotechnology, Middle East Technical University, Ankara 06800, Turkey
| | - Saniye Soylemez
- Department of Biomedical Engineering, Necmettin Erbakan University, 42090 Konya, Turkey.
| |
Collapse
|
9
|
Zha X, Yang W, Shi L, Li Y, Zeng Q, Xu J, Yang Y. Morphology Control Strategy of Bimetallic MOF Nanosheets for Upgrading the Sensitivity of Noninvasive Glucose Detection. ACS APPLIED MATERIALS & INTERFACES 2022; 14:37843-37852. [PMID: 35947783 DOI: 10.1021/acsami.2c10760] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The precise measurement of glucose level is significant for the health management of the human body. However, the existing sensitive materials and detection methods for glucose are less satisfying for practical applications. Herein, an ultrathin reticular two-dimensional nanosheets array composed of trimesic acid (H3BTC)-based bimetal metal-organic frameworks (MOFs) and carbon cloth (CC), which is constructed through a morphology control strategy, is reported for glucose sensing. Meanwhile, this nonmoving sweat glucose sensor based on a NiCo-BTC/CC electrode has been successfully prepared by a screen printing method. Benefiting from the regular and ultrathin nanosheets array, the NiCo-BTC/CC electrode has an excellent sensitivity of 2701.29 μA mM-1 cm-2, which is about 2.4 times that of its unregulated counterpart (1127.85 μA mM-1 cm-2) in the linear range 5-205 μM. In addition, an ultralow detection limit (0.09 μM, S/N = 3) and good selectivity of NiCo-BTC/CC were also obtained. The high sensitivity of the glucose sensor based on NiCo-BTC/CC electrode is 0.174 μA μM-1 (50-1000 μM). Remarkably, the preciously designed sensor is used to detect glucose concentration in sweat with a noninvasive mode, and the results are basically consistent with those of a commercial glucose device with an invasive mode. This research exhibits potential methodology for the morphology design of bimetallic MOFs nanosheets to achieve a high accuracy rate and noninvasive and timeless measurement of a glucose sensor.
Collapse
Affiliation(s)
- Xiaoting Zha
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Wenyao Yang
- Chongqing Engineering Research Center of New Energy Storage Devices and Applications, Chongqing University of Arts and Sciences, Chongqing 402160, China
| | - Liuwei Shi
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Yi Li
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Qi Zeng
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Jianhua Xu
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
| | - Yajie Yang
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
- Yangtze Delta Region Institute (Huzhou), University of Electronic Science and Technology of China, Huzhou 313001, China
| |
Collapse
|
10
|
Cun JE, Fan X, Pan Q, Gao W, Luo K, He B, Pu Y. Copper-based metal-organic frameworks for biomedical applications. Adv Colloid Interface Sci 2022; 305:102686. [PMID: 35523098 DOI: 10.1016/j.cis.2022.102686] [Citation(s) in RCA: 46] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 04/22/2022] [Accepted: 04/25/2022] [Indexed: 12/11/2022]
Abstract
Metal-organic frameworks (MOFs) are a class of important porous, crystalline materials composed of metal ions (clusters) and organic ligands. Owing to the unique redox chemistry, photochemical and electrical property, and catalytic activity of Cu2+/+, copper-based MOFs (Cu-MOFs) have been recently and extensively explored in various biomedical fields. In this review, we first make a brief introduction to the synthesis of Cu-MOFs and their composites, and highlight the recent synthetic strategies of two most studied representatives, three-dimensional HKUST-1 and two-dimensional Cu-TCPP. The recent advances of Cu-MOFs in the applications of cancer treatment, bacterial inhibition, biosensing, biocatalysis, and wound healing are summarized and discussed. Furthermore, we propose a prospect of the future development of Cu-MOFs in biomedical fields and beyond.
Collapse
Affiliation(s)
- Ju-E Cun
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, China
| | - Xi Fan
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, China
| | - Qingqing Pan
- School of Preclinical Medicine, Chengdu University, Chengdu, China
| | - Wenxia Gao
- College of Chemistry & Materials Engineering, Wenzhou University, Wenzhou 325027, China
| | - Kui Luo
- Huaxi MR Research Center (HMRRC), Department of Radiology, West China Hospital, Functional and molecular imaging Key Laboratory of Sichuan Province, Sichuan University, Chengdu 610041, China
| | - Bin He
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, China
| | - Yuji Pu
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, China.
| |
Collapse
|
11
|
Narayanamoorthi E, Arul P, Gowthaman N, Abraham John S. Morphology dependent electrocatalytic activity of copper based porous organic frameworks via diverse chain length of linkers and counterions of metal precursor. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.139994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
12
|
A highly sensitive non-enzymatic glucose sensor based on CuNi nanoalloys through one-step electrodeposition strategy. J APPL ELECTROCHEM 2022. [DOI: 10.1007/s10800-022-01671-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
13
|
Golsanamlou Z, Mahmoudpour M, Soleymani J, Jouyban A. Applications of Advanced Materials for Non-Enzymatic Glucose Monitoring: From Invasive to the Wearable Device. Crit Rev Anal Chem 2021; 53:1116-1131. [PMID: 34894901 DOI: 10.1080/10408347.2021.2008227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
Diabetes mellitus (DM) is a global health problem leading to many complications and disabilities in life adjusting activities and even dead. Monitoring glucose levels is a key factor in diagnosis and management of DM. Conventional glucose sensors consisted of immobilized enzymes, are so susceptible to environmental conditions. In this way, nonenzymatic biosensors have attracted extensive attentions in many clinical diagnostics applications. To date, the finger pricking test is a common enzyme-based glucometer that is an invasive and inconvenient and may lead to infections in the injection sites. So, working on the possibility of cutaneous or subcutaneous insertion of devices as a noninvasive or minimally-invasive systems for continuous glucose controlling approaches through human biofluids (blood, perspiration, tears, saliva, etc.) have stimulated growing interest. This review summarizes recent nonenzymatic and noninvasive biofluids glucose monitoring systems which are highly resilience and stretchable to continuously adapt to body movements during common physical activity. Sensors are based on their constituent materials including carbon-based, metal nanoparticles, polymer, and hydrogel systems are classified for electrochemical, and optical glucose detection. Finally, we address the drawbacks and challenges of enzyme-free sensors which are aroused sustaining research passion to be used in point-of-care medical diagnostics applications.
Collapse
Affiliation(s)
- Zahra Golsanamlou
- Student Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mansour Mahmoudpour
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Jafar Soleymani
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Abolghasem Jouyban
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Faculty of Pharmacy, Near East University, Nicosia, Turkey
| |
Collapse
|
14
|
Xu X, Tan R, Lv X, Geng C, Li Y, Cui B, Fang Y. Non-enzymatic electrochemical detection of glucose using Ni-Cu bimetallic alloy nanoparticles loaded on reduced graphene oxide through a one-step synthesis strategy. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:5628-5637. [PMID: 34780592 DOI: 10.1039/d1ay01357b] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In this work, Ni-Cu bimetallic alloy nanoparticles supported on reduced graphene oxide (Ni-Cu ANPs/RGO) was successfully fabricated through a one-step hydrothermal synthesis method, where simultaneous reduction of graphene oxide, nickel salt and copper salt was performed, and relevant characterization studies were executed. This synthetic method does not require surfactants and high temperature treatment, and is recommended as a green, convenient and effective way to produce composites. The unique two-dimensional architecture of the RGO provides a large specific surface area, contributing to loading more Ni-Cu ANPs, while the uniformly distributed Ni-Cu bimetallic alloy nanoparticles enhance the electrocatalytic performance of glucose oxidation. The non-enzymatic glucose biosensor based on Ni-Cu ANPs/RGO showed a wide linear range (from 0.01 μM to 30 μM), low detection limit (0.005 μM), and excellent sensitivity (1754.72 μA mM-1 cm-2). More importantly, the high reliability and the excellent selectivity in actual sample detection will broaden its practical application in electrochemical sensing.
Collapse
Affiliation(s)
- Xiaoyun Xu
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, China.
| | - Rong Tan
- College of Science, Huzhou University, Huzhou, Zhejiang, 313000, China
| | - Xiaoyi Lv
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, China.
| | - Chao Geng
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, China.
| | - Yanping Li
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, China.
| | - Bo Cui
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, China.
| | - Yishan Fang
- State Key Laboratory of Biobased Material and Green Papermaking, School of Food Science and Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, China.
| |
Collapse
|
15
|
|
16
|
Gorle DB, Ponnada S, Kiai MS, Nair KK, Nowduri A, Swart HC, Ang EH, Nanda KK. Review on recent progress in metal-organic framework-based materials for fabricating electrochemical glucose sensors. J Mater Chem B 2021; 9:7927-7954. [PMID: 34612291 DOI: 10.1039/d1tb01403j] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Diabetes is a type of disease that threatens human health, which can be diagnosed based on the level of glucose in the blood. Recently, various MOF-based materials have been developed as efficient electrochemical glucose sensors because of their tunable pore channels, large specific surface area well dispersed metallic active sites, etc. In this review, the significance of glucose detection and the advantages of MOF-based materials for this application are primarily discussed. Then, the application of MOF-based materials can be categorized into two types of glucose sensors: enzymatic biosensors and non-enzymatic sensors. Finally, insights into the current research challenges and future breakthrough possibilities regarding electrochemical glucose sensors are considered.
Collapse
Affiliation(s)
- Demudu Babu Gorle
- Materials Research Centre, Indian Institute of Science, Bangalore-560012, India.
| | - Srikanth Ponnada
- Department of Engineering Chemistry, Andhra University College of Engineering, Andhra University, Visakhapatnam-530003, India
| | - Maryam Sadat Kiai
- Nano-Science and Nano-Engineering Program, Graduate School of Science, Engineering and Technology, Istanbul Technical University, Istanbul-34469, Turkey
| | - Kishore Kumar Nair
- Department of Physics, University of Free state, Bloemfontein-9300, South Africa
| | - Annapurna Nowduri
- Department of Engineering Chemistry, Andhra University College of Engineering, Andhra University, Visakhapatnam-530003, India
| | - Hendrik C Swart
- Department of Physics, University of Free state, Bloemfontein-9300, South Africa
| | - Edison Huixiang Ang
- Natural Sciences and Science Education, National Institute of Education Singapore, Nanyang Technological University Singapore, Nanyang Walk-637616, Singapore
| | - Karuna Kar Nanda
- Materials Research Centre, Indian Institute of Science, Bangalore-560012, India.
| |
Collapse
|
17
|
Lei L, Zhang Y, Jiang Y, Xiong L, Liu Y, Li CM. Oxygen‐vacancy‐enhanced Catalytic Activity of Au@Co
3
O
4
/CeO
2
Yolk‐shell Nanocomposite to Electrochemically Detect Hydrogen Peroxide. ELECTROANAL 2021. [DOI: 10.1002/elan.202100249] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Lingli Lei
- Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University) Ministry of Education School of Materials and Energy Southwest University Chongqing 400715 P. R. China
| | - Yuanyuan Zhang
- Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University) Ministry of Education School of Materials and Energy Southwest University Chongqing 400715 P. R. China
| | - Ying Jiang
- Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University) Ministry of Education School of Materials and Energy Southwest University Chongqing 400715 P. R. China
| | - Lulu Xiong
- Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University) Ministry of Education School of Materials and Energy Southwest University Chongqing 400715 P. R. China
| | - Yingshuai Liu
- Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University) Ministry of Education School of Materials and Energy Southwest University Chongqing 400715 P. R. China
| | - Chang Ming Li
- Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University) Ministry of Education School of Materials and Energy Southwest University Chongqing 400715 P. R. China
- School of Material Science and Engineering Institute of Materials Science and Devices Suzhou University of Science and Technology Suzhou 215011 P. R. China
- Institute of Advanced Cross-field Science and College of Life Science Qingdao University Qingdao 200671 P. R. China
| |
Collapse
|
18
|
Jin X, Li G, Xu T, Su L, Yan D, Zhang X. Ruthenium‐based Conjugated Polymer and Metal‐organic Framework Nanocomposites for Glucose Sensing. ELECTROANAL 2021. [DOI: 10.1002/elan.202100148] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Xiaofeng Jin
- School of Biomedical Engineering Shenzhen University, Shenzhen Guangdong 518060 China
| | - Guanhua Li
- Shenzhen Refresh Intelligent Technology Co., Ltd., Shenzhen Guangdong 518060 China
| | - Tailin Xu
- School of Biomedical Engineering Shenzhen University, Shenzhen Guangdong 518060 China
| | - Lei Su
- School of Biomedical Engineering Shenzhen University, Shenzhen Guangdong 518060 China
| | - Dan Yan
- Shenzhen Refresh Intelligent Technology Co., Ltd., Shenzhen Guangdong 518060 China
| | - Xueji Zhang
- School of Biomedical Engineering Shenzhen University, Shenzhen Guangdong 518060 China
| |
Collapse
|
19
|
Xu Z, Wang Q, Li R, Zhangsun H, Dong M, Wang L. Surface Selenylation Engineering for Construction of a Hierarchical NiSe 2/Carbon Nanorod: A High-Performance Nonenzymatic Glucose Sensor. ACS APPLIED MATERIALS & INTERFACES 2021; 13:22866-22873. [PMID: 33970598 DOI: 10.1021/acsami.1c04831] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
As glucose (Glu) is an essential substance for metabolism as well as a symbol to diagnose diabetes, the demand of Glu sensors has increased significantly in recent decades. In this work, a hierarchical Ni-based electrochemical enzyme-free Glu sensor, namely, NiSe2/CNR (carbon nanorod), was engineered through a facile thermal treatment using dimethylglyoxime dinickel salt with selenium (Se) powder. The prepared NiSe2/CNR not only subtly introduces a hierarchical structure with rod-like carbon nanorods and rock-like NiSe2 nanoparticles, which are extremely helpful in offering a greater catalytic activity area and more catalytic active sites, but also incorporates the Se element to increase the inherent activity. The fabricated NiSe2/CNR exhibits distinguished performance for Glu detection in alkaline electrolytes with linear ranges of 0.5-411 μM and 411 μM to 6.311 mM, high sensitivities of 3636 μA mM-1 cm-2 at low concentrations, and 2121 μA mM-1 cm-2 at high concentrations, as well as a low detection limit of 380 nM (S/N = 3). It also possesses favorable reproducibility, stability, and long-term storage capacity. The practical feasibility of NiSe2/CNR was also validated by detecting Glu in human serum. Moreover, the prepared hierarchical NiSe2/CNR is of general interest for the construction of hierarchical Ni-based sensors.
Collapse
Affiliation(s)
- Zhihao Xu
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| | - Qinzhi Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| | - Ruixia Li
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| | - Hui Zhangsun
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| | - Mengna Dong
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| | - Li Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| |
Collapse
|
20
|
Kim SE, Muthurasu A. Highly Oriented Nitrogen‐doped Carbon Nanotube Integrated Bimetallic Cobalt Copper Organic Framework for Non‐enzymatic Electrochemical Glucose and Hydrogen Peroxide Sensor. ELECTROANAL 2021. [DOI: 10.1002/elan.202060566] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- So eun Kim
- Department of Emergency Medicine Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital Jeonju Korea
- Department of Nano Convergence Engineering Jeonbuk National University Republic Korea Jeonju 561-756, Republic of Korea
| | - Alagan Muthurasu
- Department of Nano Convergence Engineering Jeonbuk National University Republic Korea Jeonju 561-756, Republic of Korea
| |
Collapse
|
21
|
Liu Q, Chen J, Yu F, Wu J, Liu Z, Peng B. Multifunctional book-like CuCo-MOF for highly sensitive glucose detection and electrocatalytic oxygen evolution. NEW J CHEM 2021. [DOI: 10.1039/d1nj02931b] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Bimetallic book-like CuCo-MOF were fixed on carbon fiber paper as efficient catalyst for electrochemical glucose detection and oxygen evolution reaction.
Collapse
Affiliation(s)
- Qingcui Liu
- School of Chemistry and Chemical Engineering / Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
- Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region / Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
- Clean Energy Conversion and Storage Research Group, Shihezi University, Shihezi, 832003, P. R. China
| | - Jianhong Chen
- School of Chemistry and Chemical Engineering / Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
- Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region / Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
- Clean Energy Conversion and Storage Research Group, Shihezi University, Shihezi, 832003, P. R. China
| | - Feng Yu
- School of Chemistry and Chemical Engineering / Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
- Clean Energy Conversion and Storage Research Group, Shihezi University, Shihezi, 832003, P. R. China
| | - Jianning Wu
- School of Chemistry and Chemical Engineering / Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
- Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region / Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
| | - Zhiyong Liu
- School of Chemistry and Chemical Engineering / Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
- Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region / Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
| | - Banghua Peng
- School of Chemistry and Chemical Engineering / Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
- Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region / Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003, P. R. China
- Clean Energy Conversion and Storage Research Group, Shihezi University, Shihezi, 832003, P. R. China
| |
Collapse
|