1
|
Santala OE, Lipponen JA, Jäntti H, Rissanen TT, Tarvainen MP, Väliaho ES, Rantula OA, Naukkarinen NS, Hartikainen JEK, Martikainen TJ, Halonen J. Novel Technologies in the Detection of Atrial Fibrillation: Review of Literature and Comparison of Different Novel Technologies for Screening of Atrial Fibrillation. Cardiol Rev 2024; 32:440-447. [PMID: 36946975 PMCID: PMC11296284 DOI: 10.1097/crd.0000000000000526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/23/2023]
Abstract
Atrial fibrillation (AF) is globally the most common arrhythmia associated with significant morbidity and mortality. It impairs the quality of the patient's life, imposing a remarkable burden on public health, and the healthcare budget. The detection of AF is important in the decision to initiate anticoagulation therapy to prevent thromboembolic events. Nonetheless, AF detection is still a major clinical challenge as AF is often paroxysmal and asymptomatic. AF screening recommendations include opportunistic or systematic screening in patients ≥65 years of age or in those individuals with other characteristics pointing to an increased risk of stroke. The popularities of well-being and taking personal responsibility for one's own health are reflected in the continuous development and growth of mobile health technologies. These novel mobile health technologies could provide a cost-effective solution for AF screening and an additional opportunity to detect AF, particularly its paroxysmal and asymptomatic forms.
Collapse
Affiliation(s)
- Onni E. Santala
- From the School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
- Doctoral School, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
| | - Jukka A. Lipponen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Helena Jäntti
- Centre for Prehospital Emergency Care, Kuopio University Hospital, Kuopio, Finland
| | | | - Mika P. Tarvainen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
- Department of Clinical Physiology and Nuclear Medicine, Kuopio University Hospital, Kuopio, Finland
| | - Eemu-Samuli Väliaho
- From the School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
- Doctoral School, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
| | - Olli A. Rantula
- From the School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
- Doctoral School, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
| | - Noora S. Naukkarinen
- From the School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
- Doctoral School, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
| | - Juha E. K. Hartikainen
- From the School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
- Heart Center, Kuopio University Hospital, Kuopio, Finland
| | | | - Jari Halonen
- From the School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
- Heart Center, Kuopio University Hospital, Kuopio, Finland
| |
Collapse
|
2
|
Lingawi S, Hutton J, Khalili M, Shadgan B, Christenson J, Grunau B, Kuo C. Cardiorespiratory Sensors and Their Implications for Out-of-Hospital Cardiac Arrest Detection: A Systematic Review. Ann Biomed Eng 2024; 52:1136-1158. [PMID: 38358559 DOI: 10.1007/s10439-024-03442-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Accepted: 01/03/2024] [Indexed: 02/16/2024]
Abstract
Out-of-hospital cardiac arrest (OHCA) is a major health problem, with a poor survival rate of 2-11%. For the roughly 75% of OHCAs that are unwitnessed, survival is approximately 2-4.4%, as there are no bystanders present to provide life-saving interventions and alert Emergency Medical Services. Sensor technologies may reduce the number of unwitnessed OHCAs through automated detection of OHCA-associated physiological changes. However, no technologies are widely available for OHCA detection. This review identifies research and commercial technologies developed for cardiopulmonary monitoring that may be best suited for use in the context of OHCA, and provides recommendations for technology development, testing, and implementation. We conducted a systematic review of published studies along with a search of grey literature to identify technologies that were able to provide cardiopulmonary monitoring, and could be used to detect OHCA. We searched MEDLINE, EMBASE, Web of Science, and Engineering Village using MeSH keywords. Following inclusion, we summarized trends and findings from included studies. Our searches retrieved 6945 unique publications between January, 1950 and May, 2023. 90 studies met the inclusion criteria. In addition, our grey literature search identified 26 commercial technologies. Among included technologies, 52% utilized electrocardiography (ECG) and 40% utilized photoplethysmography (PPG) sensors. Most wearable devices were multi-modal (59%), utilizing more than one sensor simultaneously. Most included devices were wearable technologies (84%), with chest patches (22%), wrist-worn devices (18%), and garments (14%) being the most prevalent. ECG and PPG sensors are heavily utilized in devices for cardiopulmonary monitoring that could be adapted to OHCA detection. Developers seeking to rapidly develop methods for OHCA detection should focus on using ECG- and/or PPG-based multimodal systems as these are most prevalent in existing devices. However, novel sensor technology development could overcome limitations in existing sensors and could serve as potential additions to or replacements for ECG- and PPG-based devices.
Collapse
Affiliation(s)
- Saud Lingawi
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada.
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada.
- Centre for Aging SMART, University of British Columbia, 2635 Laurel St., Vancouver, BC, V5Z 1M9, Canada.
| | - Jacob Hutton
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- British Columbia Emergency Health Services, Vancouver, Canada
- Department of Emergency Medicine, University of British Columbia and St. Paul's Hospital, Vancouver, BC, Canada
- Centre for Advancing Health Outcomes, University of British Columbia, Vancouver, BC, Canada
| | - Mahsa Khalili
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- Centre for Aging SMART, University of British Columbia, 2635 Laurel St., Vancouver, BC, V5Z 1M9, Canada
- Department of Emergency Medicine, University of British Columbia and St. Paul's Hospital, Vancouver, BC, Canada
- Centre for Advancing Health Outcomes, University of British Columbia, Vancouver, BC, Canada
| | - Babak Shadgan
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada
- Department of Orthopedic Surgery, University of British Columbia, Vancouver, BC, Canada
- International Collaboration on Repair Discoveries, Vancouver, BC, Canada
| | - Jim Christenson
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- British Columbia Emergency Health Services, Vancouver, Canada
- Department of Emergency Medicine, University of British Columbia and St. Paul's Hospital, Vancouver, BC, Canada
- Centre for Advancing Health Outcomes, University of British Columbia, Vancouver, BC, Canada
| | - Brian Grunau
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- British Columbia Emergency Health Services, Vancouver, Canada
- Department of Emergency Medicine, University of British Columbia and St. Paul's Hospital, Vancouver, BC, Canada
- Centre for Advancing Health Outcomes, University of British Columbia, Vancouver, BC, Canada
| | - Calvin Kuo
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada
- Centre for Aging SMART, University of British Columbia, 2635 Laurel St., Vancouver, BC, V5Z 1M9, Canada
| |
Collapse
|
3
|
Kwon S, Choi EK, Lee SR, Oh S, Song HS, Lee YS, Han SJ, Lim HE. Comparison of Novel Telemonitoring System Using the Single-lead Electrocardiogram Patch With Conventional Telemetry System. Korean Circ J 2024; 54:140-153. [PMID: 38506104 PMCID: PMC10961211 DOI: 10.4070/kcj.2023.0252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 12/14/2023] [Accepted: 01/02/2024] [Indexed: 03/21/2024] Open
Abstract
BACKGROUND AND OBJECTIVES Although a single-lead electrocardiogram (ECG) patch may provide advantages for detecting arrhythmias in outpatient settings owing to user convenience, its comparative effectiveness for real-time telemonitoring in inpatient settings remains unclear. We aimed to compare a novel telemonitoring system using a single-lead ECG patch with a conventional telemonitoring system in an inpatient setting. METHODS This was a single-center, prospective cohort study. Patients admitted to the cardiology unit for arrhythmia treatment who required a wireless ECG telemonitoring system were enrolled. A single-lead ECG patch and conventional telemetry were applied simultaneously in hospitalized patients for over 24 hours for real-time telemonitoring. The basic ECG parameters, arrhythmia episodes, and signal loss or noise were compared between the 2 systems. RESULTS Eighty participants (mean age 62±10 years, 76.3% male) were enrolled. The three most common indications for ECG telemonitoring were atrial fibrillation (66.3%), sick sinus syndrome (12.5%), and atrioventricular block (10.0%). The intra-class correlation coefficients for detecting the number of total beats, atrial and ventricular premature complexes, maximal, average, and minimal heart rates, and pauses were all over 0.9 with p values for reliability <0.001. Compared to a conventional system, a novel system demonstrated significantly lower signal noise (median 0.3% [0.1-1.6%] vs. 2.4% [1.4-3.7%], p<0.001) and fewer episodes of signal loss (median 22 [2-53] vs. 64 [22-112] episodes, p=0.002). CONCLUSIONS The novel telemonitoring system using a single-lead ECG patch offers performance comparable to that of a conventional system while significantly reducing signal loss and noise. TRIAL REGISTRATION Clinical Research Information Service Identifier: KCT0008176.
Collapse
Affiliation(s)
- Soonil Kwon
- Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
| | - Eue-Keun Choi
- Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea.
| | - So-Ryoung Lee
- Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea
| | - Seil Oh
- Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea
| | | | | | - Sang-Jin Han
- Division of Cardiology, Department of Internal Medicine, Hallym University Medical Center, Anyang, Korea
| | - Hong Euy Lim
- Division of Cardiology, Department of Internal Medicine, Hallym University Medical Center, Anyang, Korea.
| |
Collapse
|
4
|
Kim S, Choi Y, Lee K, Kim SH, Kim H, Shin S, Park S, Oh YS. Comparison of the 11-Day Adhesive ECG Patch Monitor and 24-h Holter Tests to Assess the Response to Antiarrhythmic Drug Therapy in Paroxysmal Atrial Fibrillation. Diagnostics (Basel) 2023; 13:3078. [PMID: 37835822 PMCID: PMC10572592 DOI: 10.3390/diagnostics13193078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 09/25/2023] [Accepted: 09/27/2023] [Indexed: 10/15/2023] Open
Abstract
Accurate assessment of the response to the antiarrhythmic drug (AAD) in atrial fibrillation (AF) is crucial to achieve adequate rhythm control. We evaluated the effectiveness of extended cardiac monitoring using an adhesive ECG patch in the detection of drug-refractory paroxysmal AF. Patients diagnosed with paroxysmal AF and receiving AAD therapy were enrolled. The subjects simultaneously underwent 11-day adhesive ECG patch monitoring and a 24-h Holter test. The primary study outcome was a detection rate of drug-refractory AF or atrial tachycardia (AT) lasting ≥30 s. A total of 59 patients were enrolled and completed the study examinations. AF or AT was detected in 28 (47.5%) patients by an 11-day ECG patch monitor and in 8 (13.6%) patients by a 24-h Holter test (p < 0.001). The 11-day ECG patch monitor identified an additional 20 patients (33.8%) with drug-refractory AF not detected by the 24-h Holter, and as a result, the treatment plan was changed in 11 patients (10 catheter ablations, one medication change). In conclusion, extended cardiac rhythm monitoring using an adhesive ECG patch in patients with paroxysmal AF under AAD therapy led to over a threefold higher detection of drug-refractory AF episodes, compared to the 24-h Holter test.
Collapse
Affiliation(s)
- Soohyun Kim
- Division of Cardiology, Department of Internal Medicine, Seoul St. Mary Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea; (S.K.); (S.-H.K.); (H.K.); (S.S.); (S.P.)
- Cardiovascular Research Institute for Intractable Disease, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
| | - Young Choi
- Division of Cardiology, Department of Internal Medicine, Seoul St. Mary Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea; (S.K.); (S.-H.K.); (H.K.); (S.S.); (S.P.)
- Cardiovascular Research Institute for Intractable Disease, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
| | - Kichang Lee
- Cardiovascular Research Center, Massachusetts General Hospital, Boston, MA 02114, USA;
- Harvard Medical School, Boston, MA 02115, USA
| | - Sung-Hwan Kim
- Division of Cardiology, Department of Internal Medicine, Seoul St. Mary Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea; (S.K.); (S.-H.K.); (H.K.); (S.S.); (S.P.)
- Cardiovascular Research Institute for Intractable Disease, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
| | - Hwajung Kim
- Division of Cardiology, Department of Internal Medicine, Seoul St. Mary Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea; (S.K.); (S.-H.K.); (H.K.); (S.S.); (S.P.)
- Cardiovascular Research Institute for Intractable Disease, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
| | - Sanghoon Shin
- Division of Cardiology, Department of Internal Medicine, Seoul St. Mary Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea; (S.K.); (S.-H.K.); (H.K.); (S.S.); (S.P.)
| | - Soyoon Park
- Division of Cardiology, Department of Internal Medicine, Seoul St. Mary Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea; (S.K.); (S.-H.K.); (H.K.); (S.S.); (S.P.)
- Cardiovascular Research Institute for Intractable Disease, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
| | - Yong-Seog Oh
- Division of Cardiology, Department of Internal Medicine, Seoul St. Mary Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea; (S.K.); (S.-H.K.); (H.K.); (S.S.); (S.P.)
- Cardiovascular Research Institute for Intractable Disease, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
| |
Collapse
|
5
|
Zinglersen AH, Drange IL, Myhr KA, Fuchs A, Pfeiffer-Jensen M, Brock C, Jacobsen S. Vagus nerve stimulation as a novel treatment for systemic lupus erythematous: study protocol for a randomised, parallel-group, sham-controlled investigator-initiated clinical trial, the SLE-VNS study. BMJ Open 2022; 12:e064552. [PMID: 36127117 PMCID: PMC9490576 DOI: 10.1136/bmjopen-2022-064552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
INTRODUCTION Systemic lupus erythematosus (SLE) is a chronic autoimmune disease. SLE is treated with immunosuppressants with suboptimal efficacy and high risk of serious side effects. Patients with SLE have increased risk of mortality, organ damage and debilitating treatment-resistant fatigue. Autonomic nervous system dysfunction (AD) is present in approximately half of the patients and may promote autoimmunity by weakening the vagally mediated anti-inflammatory reflex. Recent studies suggest that transcutaneous vagus nerve stimulation (tVNS) has few side effects and beneficial effects on fatigue, pain, disease activity and organ function. This study investigates whether adjuvant tVNS improves measures of fatigue (primary end point), AD, clinical disease activity, inflammation, pain, organ function and quality of life.Hence, this study will contribute to the understanding of AD as a potentially important precursor of fatigue, disease activity, progression and complications in SLE, and how tVNS mechanistically may attenuate this. As adjuvant tVNS use may reduce the need for traditional immunosuppressive therapy, this trial may prompt a shift in the treatment of SLE and potentially other autoimmune disorders. METHODS AND ANALYSIS Eighty-four patients with SLE with fatigue and AD will be randomised 1:1 to active or sham tVNS in this double-blinded parallel-group study. In period 1 (1 week), participants will receive a 4 min tVNS 4 times daily and report on fatigue daily. After a 2-week pause, period 2 (8 weeks) will entail tVNS twice daily and participants will report on fatigue, pain and disease activity weekly. Secondary end points will be assessed before and after each period and after 1 week in period 2. ETHICS AND DISSEMINATION The study is approved by the Danish Medical Research Ethical Committees (case no: 2120231) and results will be published in international peer-reviewed journals. TRIAL REGISTRATION NUMBER NCT05315739.
Collapse
Affiliation(s)
- Amanda Hempel Zinglersen
- Copenhagen Research Center for Autoimmune Connective Tissue Diseases (COPEACT), Department of Rheumatology, Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen Faculty of Health and Medical Sciences, Copenhagen, Denmark
| | - Ida Lynghøj Drange
- Copenhagen Research Center for Autoimmune Connective Tissue Diseases (COPEACT), Department of Rheumatology, Rigshospitalet, Copenhagen, Denmark
| | - Katrine Aagaard Myhr
- Department of Clinical Medicine, University of Copenhagen Faculty of Health and Medical Sciences, Copenhagen, Denmark
- Department of Cardiology, Rigshospitalet, Copenhagen, Denmark
| | - Andreas Fuchs
- Department of Cardiology, Rigshospitalet, Copenhagen, Denmark
| | - Mogens Pfeiffer-Jensen
- Department of Clinical Medicine, University of Copenhagen Faculty of Health and Medical Sciences, Copenhagen, Denmark
- Copenhagen Center for Arthritis Research (COPECARE), Department of Rheumatology, Rigshospitalet, Glostrup, Denmark
| | - Christina Brock
- Mech-Sense, Aalborg University Hospital, Aalborg, Denmark
- Department of Clinical Medicine, Aalborg University Faculty of Medicine, Aalborg, Denmark
| | - Søren Jacobsen
- Copenhagen Research Center for Autoimmune Connective Tissue Diseases (COPEACT), Department of Rheumatology, Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen Faculty of Health and Medical Sciences, Copenhagen, Denmark
| |
Collapse
|
6
|
McIntyre WF, Wang J, Benz AP, Johnson L, Connolly SJ, Van Gelder IC, Lopes RD, Gold MR, Hohnloser SH, Lau CP, Israel CW, Wong JA, Conen D, Healey JS. Estimated incidence of previously undetected atrial fibrillation on a 14-day continuous electrocardiographic monitor and associated risk of stroke. Europace 2022; 24:1058-1064. [DOI: 10.1093/europace/euab324] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Accepted: 12/20/2021] [Indexed: 11/13/2022] Open
Abstract
Abstract
Aims
There is uncertainty about whether and how to perform screening for atrial fibrillation (AF). To estimate the incidence of previously undetected AF that would be captured using a continuous 14-day ECG monitor and the associated risk of stroke.
Methods and results
We analysed data from a cohort of patients >65 years old with hypertension and a pacemaker, but without known AF. For each participant, we simulated 1000 ECG monitors by randomly selecting 14-day windows in the 6 months following enrolment and calculated the average AF burden (total time in AF). We used Cox proportional hazards models adjusted for CHA2DS2-VASc score to estimate the risk of subsequent ischaemic stroke or systemic embolism (SSE) associated with burdens of AF > and <6 min. Among 2470 participants, the median CHA2DS2-VASc score was 4.0, and 44 patients experienced SSE after 6 months following enrolment. The proportion of participants with an AF burden >6 min was 3.10% (95% CI 2.53–3.72). This was consistent across strata of age and CHA2DS2-VASc scores. Over a mean follow-up of 2.4 years, the rate of SSE among patients with <6 min of AF was 0.70%/year, compared to 2.18%/year (adjusted HR 3.02; 95% CI 1.39–6.56) in those with >6 min of AF.
Conclusions
Approximately 3% of individuals aged >65 years with hypertension may have more than 6 min of AF detected by a 14-day ECG monitor. This is associated with a stroke risk of over 2% per year. Whether oral anticoagulation will reduce stroke in these patients is unknown.
Collapse
Affiliation(s)
- William F McIntyre
- Population Health Research Institute, 237 Barton St E C3-109, Hamilton, ON L8L 2X2, Canada
- Department of Medicine, McMaster University, Hamilton, ON, Canada
| | - Jia Wang
- Population Health Research Institute, 237 Barton St E C3-109, Hamilton, ON L8L 2X2, Canada
| | - Alexander P Benz
- Population Health Research Institute, 237 Barton St E C3-109, Hamilton, ON L8L 2X2, Canada
| | - Linda Johnson
- Population Health Research Institute, 237 Barton St E C3-109, Hamilton, ON L8L 2X2, Canada
| | - Stuart J Connolly
- Population Health Research Institute, 237 Barton St E C3-109, Hamilton, ON L8L 2X2, Canada
- Department of Medicine, McMaster University, Hamilton, ON, Canada
| | - Isabelle C Van Gelder
- Department of Cardiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Renato D Lopes
- Duke Clinical Research Institute, Duke Medicine, Durham, NC, USA
| | - Michael R Gold
- Division of Cardiology, Medical University of South Carolina, Charleston, SC, USA
| | - Stefan H Hohnloser
- Department of Electrophysiology, J.W. Goetshe University, Frankfurt, Germany
| | - Chu-Pak Lau
- Department of Medicine, Queen Mary Hospital, University of Hong Kong, Hong Kong, China
| | - Carsten W Israel
- Division of Cardiology, Department of Medicine, Evangelical Hospital Bielefeld, Bielefeld, Germany
| | - Jorge A Wong
- Population Health Research Institute, 237 Barton St E C3-109, Hamilton, ON L8L 2X2, Canada
- Department of Medicine, McMaster University, Hamilton, ON, Canada
| | - David Conen
- Population Health Research Institute, 237 Barton St E C3-109, Hamilton, ON L8L 2X2, Canada
- Department of Medicine, McMaster University, Hamilton, ON, Canada
| | - Jeff S Healey
- Population Health Research Institute, 237 Barton St E C3-109, Hamilton, ON L8L 2X2, Canada
- Department of Medicine, McMaster University, Hamilton, ON, Canada
| |
Collapse
|
7
|
Guess M, Zavanelli N, Yeo WH. Recent Advances in Materials and Flexible Sensors for Arrhythmia Detection. MATERIALS 2022; 15:ma15030724. [PMID: 35160670 PMCID: PMC8836661 DOI: 10.3390/ma15030724] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 01/06/2022] [Accepted: 01/16/2022] [Indexed: 12/24/2022]
Abstract
Arrhythmias are one of the leading causes of death in the United States, and their early detection is essential for patient wellness. However, traditional arrhythmia diagnosis by expert evaluation from intermittent clinical examinations is time-consuming and often lacks quantitative data. Modern wearable sensors and machine learning algorithms have attempted to alleviate this problem by providing continuous monitoring and real-time arrhythmia detection. However, current devices are still largely limited by the fundamental mismatch between skin and sensor, giving way to motion artifacts. Additionally, the desirable qualities of flexibility, robustness, breathability, adhesiveness, stretchability, and durability cannot all be met at once. Flexible sensors have improved upon the current clinical arrhythmia detection methods by following the topography of skin and reducing the natural interface mismatch between cardiac monitoring sensors and human skin. Flexible bioelectric, optoelectronic, ultrasonic, and mechanoelectrical sensors have been demonstrated to provide essential information about heart-rate variability, which is crucial in detecting and classifying arrhythmias. In this review, we analyze the current trends in flexible wearable sensors for cardiac monitoring and the efficacy of these devices for arrhythmia detection.
Collapse
Affiliation(s)
- Matthew Guess
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; (M.G.); (N.Z.)
- Center for Human-Centric Interfaces and Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Nathan Zavanelli
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; (M.G.); (N.Z.)
- Center for Human-Centric Interfaces and Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Woon-Hong Yeo
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; (M.G.); (N.Z.)
- Center for Human-Centric Interfaces and Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
- Parker H. Petit Institute for Bioengineering and Biosciences, Neural Engineering Center, Institute for Materials, Institute for Robotics and Intelligent Machines, Georgia Institute of Technology, Atlanta, GA 30332, USA
- Correspondence: ; Tel.: +1-404-385-5710
| |
Collapse
|
8
|
Santala OE, Halonen J, Martikainen S, Jäntti H, Rissanen TT, Tarvainen MP, Laitinen TP, Laitinen TM, Väliaho ES, Hartikainen JEK, Martikainen TJ, Lipponen JA. Automatic Mobile Health Arrhythmia Monitoring for the Detection of Atrial Fibrillation: Prospective Feasibility, Accuracy, and User Experience Study. JMIR Mhealth Uhealth 2021; 9:e29933. [PMID: 34677135 PMCID: PMC8571685 DOI: 10.2196/29933] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 06/30/2021] [Accepted: 08/27/2021] [Indexed: 01/19/2023] Open
Abstract
Background Atrial fibrillation (AF) is the most common tachyarrhythmia and associated with a risk of stroke. The detection and diagnosis of AF represent a major clinical challenge due to AF’s asymptomatic and intermittent nature. Novel consumer-grade mobile health (mHealth) products with automatic arrhythmia detection could be an option for long-term electrocardiogram (ECG)-based rhythm monitoring and AF detection. Objective We evaluated the feasibility and accuracy of a wearable automated mHealth arrhythmia monitoring system, including a consumer-grade, single-lead heart rate belt ECG device (heart belt), a mobile phone application, and a cloud service with an artificial intelligence (AI) arrhythmia detection algorithm for AF detection. The specific aim of this proof-of-concept study was to test the feasibility of the entire sequence of operations from ECG recording to AI arrhythmia analysis and ultimately to final AF detection. Methods Patients (n=159) with an AF (n=73) or sinus rhythm (n=86) were recruited from the emergency department. A single-lead heart belt ECG was recorded for 24 hours. Simultaneously registered 3-lead ECGs (Holter) served as the gold standard for the final rhythm diagnostics and as a reference device in a user experience survey with patients over 65 years of age (high-risk group). Results The heart belt provided a high-quality ECG recording for visual interpretation resulting in 100% accuracy, sensitivity, and specificity of AF detection. The accuracy of AF detection with the automatic AI arrhythmia detection from the heart belt ECG recording was also high (97.5%), and the sensitivity and specificity were 100% and 95.4%, respectively. The correlation between the automatic estimated AF burden and the true AF burden from Holter recording was >0.99 with a mean burden error of 0.05 (SD 0.26) hours. The heart belt demonstrated good user experience and did not significantly interfere with the patient’s daily activities. The patients preferred the heart belt over Holter ECG for rhythm monitoring (85/110, 77% heart belt vs 77/109, 71% Holter, P=.049). Conclusions A consumer-grade, single-lead ECG heart belt provided good-quality ECG for rhythm diagnosis. The mHealth arrhythmia monitoring system, consisting of heart-belt ECG, a mobile phone application, and an automated AF detection achieved AF detection with high accuracy, sensitivity, and specificity. In addition, the mHealth arrhythmia monitoring system showed good user experience. Trial Registration ClinicalTrials.gov NCT03507335; https://clinicaltrials.gov/ct2/show/NCT03507335
Collapse
Affiliation(s)
- Onni E Santala
- School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland.,Doctoral School, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
| | - Jari Halonen
- School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland.,Heart Center, Kuopio University Hospital, Kuopio, Finland
| | - Susanna Martikainen
- Department of Health and Social Management, University of Eastern Finland, Kuopio, Finland
| | - Helena Jäntti
- Center for Prehospital Emergency Care, Kuopio University Hospital, Kuopio, Finland
| | | | - Mika P Tarvainen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.,Department of Clinical Physiology and Nuclear Medicine, Kuopio University Hospital, Kuopio, Finland
| | - Tomi P Laitinen
- School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland.,Department of Clinical Physiology and Nuclear Medicine, Kuopio University Hospital, Kuopio, Finland
| | - Tiina M Laitinen
- Department of Clinical Physiology and Nuclear Medicine, Kuopio University Hospital, Kuopio, Finland
| | - Eemu-Samuli Väliaho
- School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland.,Doctoral School, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
| | - Juha E K Hartikainen
- School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland.,Heart Center, Kuopio University Hospital, Kuopio, Finland
| | - Tero J Martikainen
- Department of Emergency Care, Kuopio University Hospital, Kuopio, Finland
| | - Jukka A Lipponen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
9
|
Gladstone DJ, Wachter R, Schmalstieg-Bahr K, Quinn FR, Hummers E, Ivers N, Marsden T, Thornton A, Djuric A, Suerbaum J, von Grünhagen D, McIntyre WF, Benz AP, Wong JA, Merali F, Henein S, Nichol C, Connolly SJ, Healey JS. Screening for Atrial Fibrillation in the Older Population: A Randomized Clinical Trial. JAMA Cardiol 2021; 6:558-567. [PMID: 33625468 DOI: 10.1001/jamacardio.2021.0038] [Citation(s) in RCA: 100] [Impact Index Per Article: 33.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Importance Atrial fibrillation (AF) is a major cause of preventable strokes. Screening asymptomatic individuals for AF may increase anticoagulant use for stroke prevention. Objective To evaluate 2 home-based AF screening interventions. Design, Setting, and Participants This multicenter randomized clinical trial recruited individuals from primary care practices aged 75 years or older with hypertension and without known AF. From April 5, 2015, to March 26, 2019, 856 participants were enrolled from 48 practices. Interventions The control group received standard care (routine clinical follow-up plus a pulse check and heart auscultation at baseline and 6 months). The screening group received a 2-week continuous electrocardiographic (cECG) patch monitor to wear at baseline and at 3 months, in addition to standard care. The screening group also received automated home blood pressure (BP) machines with oscillometric AF screening capability to use twice-daily during the cECG monitoring periods. Main Outcomes and Measures With intention-to-screen analysis, the primary outcome was AF detected by cECG monitoring or clinically within 6 months. Secondary outcomes included anticoagulant use, device adherence, and AF detection by BP monitors. Results Of the 856 participants, 487 were women (56.9%); mean (SD) age was 80.0 (4.0) years. Median cECG wear time was 27.4 of 28 days (interquartile range [IQR], 18.4-28.0 days). In the primary analysis, AF was detected in 23 of 434 participants (5.3%) in the screening group vs 2 of 422 (0.5%) in the control group (relative risk, 11.2; 95% CI, 2.7-47.1; P = .001; absolute difference, 4.8%; 95% CI, 2.6%-7.0%; P < .001; number needed to screen, 21). Of those with cECG-detected AF, median total time spent in AF was 6.3 hours (IQR, 4.2-14.0 hours; range 1.3 hours-28 days), and median duration of the longest AF episode was 5.7 hours (IQR, 2.9-12.9 hours). Anticoagulation was initiated in 15 of 20 patients (75.0%) with cECG-detected AF. By 6 months, anticoagulant therapy had been prescribed for 18 of 434 participants (4.1%) in the screening group vs 4 of 422 (0.9%) in the control group (relative risk, 4.4; 95% CI, 1.5-12.8; P = .007; absolute difference, 3.2%; 95% CI, 1.1%-5.3%; P = .003). Twice-daily AF screening using the home BP monitor had a sensitivity of 35.0% (95% CI, 15.4%-59.2%), specificity of 81.0% (95% CI, 76.7%-84.8%), positive predictive value of 8.9% (95% CI, 4.9%-15.5%), and negative predictive value of 95.9% (95% CI, 94.5%-97.0%). Adverse skin reactions requiring premature discontinuation of cECG monitoring occurred in 5 of 434 participants (1.2%). Conclusions and Relevance In this randomized clinical trial, among older community-dwelling individuals with hypertension, AF screening with a wearable cECG monitor was well tolerated, increased AF detection 10-fold, and prompted initiation of anticoagulant therapy in most cases. Compared with continuous ECG, intermittent oscillometric screening with a BP monitor was an inferior strategy for detecting paroxysmal AF. Large trials with hard clinical outcomes are now needed to evaluate the potential benefits and harms of AF screening. Trial Registration ClinicalTrials.gov Identifier: NCT02392754.
Collapse
Affiliation(s)
- David J Gladstone
- Hurvitz Brain Sciences Program, Sunnybrook Research Institute, and Division of Neurology, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.,Division of Neurology, Department of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Rolf Wachter
- Clinic and Policlinic for Cardiology, University Hospital, Leipzig, Germany.,Department of Cardiology, University Medical Center Göttingen, Göttingen, Germany.,DZHK (German Centre for Cardiovascular Research), partner site Göttingen, Göttingen, Germany
| | - Katharina Schmalstieg-Bahr
- Department of General Practice, University Medical Center Göttingen, Göttingen, Germany.,Department of General Practice and Primary Care, University Medical Center Hamburg-Eppendorf, Hamburg-Eppendorf, Germany
| | - F Russell Quinn
- Libin Cardiovascular Institute, University of Calgary, Calgary, Alberta, Canada
| | - Eva Hummers
- DZHK (German Centre for Cardiovascular Research), partner site Göttingen, Göttingen, Germany.,Department of General Practice, University Medical Center Göttingen, Göttingen, Germany
| | - Noah Ivers
- Women's College Hospital, Department of Family and Community Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Tamara Marsden
- Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| | - Andrea Thornton
- Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| | - Angie Djuric
- Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| | - Johanna Suerbaum
- Department of Cardiology, University Medical Center Göttingen, Göttingen, Germany.,DZHK (German Centre for Cardiovascular Research), partner site Göttingen, Göttingen, Germany
| | - Doris von Grünhagen
- Clinic for Cardiology and Pneumology, University Medicine Göttingen, Göttingen, Germany
| | - William F McIntyre
- Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| | - Alexander P Benz
- Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| | - Jorge A Wong
- Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| | | | - Sam Henein
- Southlake Regional Health Centre, Newmarket, Ontario, Canada
| | - Chris Nichol
- Camrose Primary Care Network, Camrose, Alberta, Canada
| | - Stuart J Connolly
- Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| | - Jeff S Healey
- Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
| | | |
Collapse
|
10
|
Kwon S, Lee SR, Choi EK, Ahn HJ, Song HS, Lee YS, Oh S. Validation of Adhesive Single-Lead ECG Device Compared with Holter Monitoring among Non-Atrial Fibrillation Patients. SENSORS (BASEL, SWITZERLAND) 2021; 21:3122. [PMID: 33946269 PMCID: PMC8124998 DOI: 10.3390/s21093122] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 04/22/2021] [Accepted: 04/26/2021] [Indexed: 11/17/2022]
Abstract
There are few reports on head-to-head comparisons of electrocardiogram (ECG) monitoring between adhesive single-lead and Holter devices for arrhythmias other than atrial fibrillation (AF). This study aimed to compare 24 h ECG monitoring between the two devices in patients with general arrhythmia. Twenty-nine non-AF patients with a workup of pre-diagnosed arrhythmias or suspicious arrhythmic episodes were evaluated. Each participant wore both devices simultaneously, and the cardiac rhythm was monitored for 24 h. Selective ECG parameters were compared between the two devices. Two cardiologists independently compared the diagnoses of each device. The two most frequent monitoring indications were workup of premature atrial contractions (41.4%) and suspicious arrhythmia-related symptoms (37.9%). The single-lead device had a higher noise burden than the Holter device (0.04 ± 0.05% vs. 0.01 ± 0.01%, p = 0.024). The number of total QRS complexes, ventricular ectopic beats, and supraventricular ectopic beats showed an excellent degree of agreement between the two devices (intraclass correlation coefficients = 0.991, 1.000, and 0.987, respectively). In addition, the minimum/average/maximum heart rates showed an excellent degree of agreement. The two cardiologists made coherent diagnoses for all 29 participants using both monitoring methods. In conclusion, the single-lead adhesive device could be an acceptable alternative for ambulatory ECG monitoring in patients with general arrhythmia.
Collapse
Affiliation(s)
- Soonil Kwon
- Department of Internal Medicine, Seoul National University Hospital, Seoul 03080, Korea; (S.K.); (S.-R.L.); (H.-J.A.); (S.O.)
| | - So-Ryoung Lee
- Department of Internal Medicine, Seoul National University Hospital, Seoul 03080, Korea; (S.K.); (S.-R.L.); (H.-J.A.); (S.O.)
| | - Eue-Keun Choi
- Department of Internal Medicine, Seoul National University Hospital, Seoul 03080, Korea; (S.K.); (S.-R.L.); (H.-J.A.); (S.O.)
- Department of Internal Medicine, College of Medicine, Seoul National University, Seoul 03080, Korea
| | - Hyo-Jeong Ahn
- Department of Internal Medicine, Seoul National University Hospital, Seoul 03080, Korea; (S.K.); (S.-R.L.); (H.-J.A.); (S.O.)
| | - Hee-Seok Song
- Seers Technology Co., Ltd., Seongnam-si 13558, Korea; (H.-S.S.); (Y.-S.L.)
| | - Young-Shin Lee
- Seers Technology Co., Ltd., Seongnam-si 13558, Korea; (H.-S.S.); (Y.-S.L.)
| | - Seil Oh
- Department of Internal Medicine, Seoul National University Hospital, Seoul 03080, Korea; (S.K.); (S.-R.L.); (H.-J.A.); (S.O.)
- Department of Internal Medicine, College of Medicine, Seoul National University, Seoul 03080, Korea
| |
Collapse
|
11
|
Rashkovska A, Depolli M, Tomašić I, Avbelj V, Trobec R. Medical-Grade ECG Sensor for Long-Term Monitoring. SENSORS 2020; 20:s20061695. [PMID: 32197444 PMCID: PMC7146736 DOI: 10.3390/s20061695] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 03/11/2020] [Accepted: 03/14/2020] [Indexed: 11/16/2022]
Abstract
The recent trend in electrocardiogram (ECG) device development is towards wireless body sensors applied for patient monitoring. The ultimate goal is to develop a multi-functional body sensor that will provide synchronized vital bio-signs of the monitored user. In this paper, we present an ECG sensor for long-term monitoring, which measures the surface potential difference between proximal electrodes near the heart, called differential ECG lead or differential lead, in short. The sensor has been certified as a class IIa medical device and is available on the market under the trademark Savvy ECG. An improvement from the user’s perspective—immediate access to the measured data—is also implemented into the design. With appropriate placement of the device on the chest, a very clear distinction of all electrocardiographic waves can be achieved, allowing for ECG recording of high quality, sufficient for medical analysis. Experimental results that elucidate the measurements from a differential lead regarding sensors’ position, the impact of artifacts, and potential diagnostic value, are shown. We demonstrate the sensors’ potential by presenting results from its various areas of application: medicine, sports, veterinary, and some new fields of investigation, like hearth rate variability biofeedback assessment and biometric authentication.
Collapse
Affiliation(s)
- Aleksandra Rashkovska
- Department of Communication Systems, Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia; (M.D.); (V.A.); (R.T.)
- Correspondence: ; Tel.: +386-1-477-3701
| | - Matjaž Depolli
- Department of Communication Systems, Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia; (M.D.); (V.A.); (R.T.)
| | - Ivan Tomašić
- Division of Intelligent Future Technologies, Mälardalen University, Högskoleplan 1, 721 23 Västerås, Sweden;
| | - Viktor Avbelj
- Department of Communication Systems, Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia; (M.D.); (V.A.); (R.T.)
| | - Roman Trobec
- Department of Communication Systems, Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia; (M.D.); (V.A.); (R.T.)
| |
Collapse
|
12
|
Periyaswamy T, Balasubramanian M. Ambulatory cardiac bio-signals: From mirage to clinical reality through a decade of progress. Int J Med Inform 2019; 130:103928. [PMID: 31434042 DOI: 10.1016/j.ijmedinf.2019.07.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Revised: 06/05/2019] [Accepted: 07/08/2019] [Indexed: 01/01/2023]
Abstract
BACKGROUND Health monitoring is shifting towards continuous, ambulatory and clinically comparable wearable devices. Telemedicine and remote diagnosis could harness the capability of mobile cardiac health information, as the technology on bio-physical signal monitoring has improved significantly. OBJECTIVES The purpose of this review article is (1) to systematically assess the viability of ambulatory electrocardiography (ECG), (2) to provide a systems level understanding of a broad spectrum of wearable heart signal monitoring approaches and (3) to identify areas of improvement in the existing technology needed to attain clinical grade diagnosis. RESULTS Based on the included literature, we have identified (1) that the developments in ECG monitoring through wearable devices are reaching feasibility, and are capable of delivering diagnostic and prognostic information, (2) that reliable sensing is the major bottleneck in the entire process of ambulatory monitoring, (3) that there is a strong need for artificial intelligence and machine learning techniques to parse and infer the biosignals and (4) that aspects of wearer comfort has largely been ignored in the prevailing developments, which can become a key factor for consumer acceptance. CONCLUSIONS Cardiac health information is crucial for diagnosis and prevention of several disease onsets. Mobile and continuous monitoring can aid avoiding risks involved with acute symptoms. The health information obtained through continuous monitoring can serve as the BigData of heart signals, and can facilitate new treatment methods and devise effective health policies.
Collapse
Affiliation(s)
- Thamizhisai Periyaswamy
- Department of Human Environmental Studies, 117 Wightman Hall, Central Michigan University, Mount Pleasant, Michigan, 48859, United States.
| | - Mahendran Balasubramanian
- Apparel Merchandising and Product Development, School of Human Environmental Science, 118 Home Economic Building, University of Arkansas, Fayetteville, Arkansas, 72701, United States.
| |
Collapse
|
13
|
Lumikari TJ, Putaala J, Kerola A, Sibolt G, Pirinen J, Pakarinen S, Lehto M, Nieminen T. Continuous 4-week ECG monitoring with adhesive electrodes reveals AF in patients with recent embolic stroke of undetermined source. Ann Noninvasive Electrocardiol 2019; 24:e12649. [PMID: 31045315 PMCID: PMC6850068 DOI: 10.1111/anec.12649] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Accepted: 03/13/2019] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND Atrial fibrillation (AF) frequently escapes routine stroke workup due to its unpredictable and often asymptomatic nature, leaving a significant portion of patients at high risk of recurrent stroke. Recent trials emphasized continuous electrocardiogram (ECG) monitoring in the detection of occult AF. We screened AF in patients meeting the embolic stroke of unknown source (ESUS) criteria using an external miniaturized recorder with an adhesive electrode. METHODS Patients aged ≥50 with recent ESUS were prospectively screened and assigned to wear a 1-lead ECG device capable to record continuous ECG for up to 4 weeks. Electrodes were replaced every 3-4 days. Primary outcome was proportion of patients completing at least 80% of monitoring. Secondary outcome measures included incidence of AF and initiation of oral anticoagulation therapy after AF detection. RESULTS Fifty-seven patients were monitored (mean age 64.5 ± 8.2 years, median delay from stroke to the start of monitoring 8 days, IQR 4-44). Of these, 51 patients (89.5%) completed at least 80% of the desired monitoring period. We detected AF ≥30 s in seven patients (12.3%), all of whom initiated anticoagulation therapy. Atrial fibrillation was revealed in six patients (85.7%) within the first week of monitoring. Compared to patients without AF, patients with AF were older (70.6 ± 5.1 vs. 63.6 ± 8.3 years, p < 0.011) and more obese (body mass index 30.0 ± 3.4 vs. 26.6 ± 4.6, p < 0.039). CONCLUSIONS Prolonged ECG monitoring with an external device using adhesive electrodes is feasible in ESUS patients, since nine out of ten patients used the device appropriately and AF was detected in one out of eight patients.
Collapse
Affiliation(s)
- Tuomas J Lumikari
- Department of Neurology, Helsinki University Hospital, Helsinki, Finland
| | - Jukka Putaala
- Department of Neurology, Helsinki University Hospital, Helsinki, Finland
| | - Anne Kerola
- Department of Internal medicine, Päijät-Häme Central Hospital, Lahti, Finland
| | - Gerli Sibolt
- Department of Neurology, Helsinki University Hospital, Helsinki, Finland
| | - Jani Pirinen
- Department of Clinical Physiology and Nuclear Medicine, HUS Medical Imaging Center, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| | - Sami Pakarinen
- Department of Cardiology, Heart and Lung Center, Helsinki University Hospital, Finland
| | - Mika Lehto
- Department of Cardiology, Heart and Lung Center, Helsinki University Hospital, Finland
| | - Tuomo Nieminen
- Department of Internal medicine, Päijät-Häme Central Hospital, Lahti, Finland
| |
Collapse
|
14
|
Ershad F, Sim K, Thukral A, Zhang YS, Yu C. Invited Article: Emerging soft bioelectronics for cardiac health diagnosis and treatment. APL MATERIALS 2019; 7:031301. [PMID: 32551188 PMCID: PMC7187908 DOI: 10.1063/1.5060270] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Accepted: 10/19/2018] [Indexed: 05/05/2023]
Abstract
Cardiovascular diseases are among the leading causes of death worldwide. Conventional technologies for diagnosing and treating lack the compliance and comfort necessary for those living with life-threatening conditions. Soft electronics presents a promising outlet for conformal, flexible, and stretchable devices that can overcome the mechanical mismatch that is often associated with conventional technologies. Here, we review the various methods in which electronics have been made flexible and stretchable, to better interface with the human body, both externally with the skin and internally with the outer surface of the heart. Then, we review soft, wearable, noninvasive heart monitors designed to be attached to the chest or other parts of the body for mechano-acoustic and electrophysiological sensing. A common method of treatment for various abnormal heart rhythms involves catheter ablation procedures and we review the current soft bioelectronics that can be placed on the balloon or head of the catheter. Cardiac mapping is integral to determine the state of the heart; we discuss the various parameters for sensing aside from electrophysiological sensing, such as temperature, pH, strain, and tactile sensing. Finally, we review the soft devices that harvest energy from the natural and spontaneous beating of the heart by converting its mechanical motion into electrical energy to power implants.
Collapse
Affiliation(s)
- Faheem Ershad
- Department of Biomedical Engineering, University
of Houston, Houston, Texas 77204, USA
| | - Kyoseung Sim
- Department of Mechanical Engineering, University
of Houston, Houston, Texas 77204, USA
| | - Anish Thukral
- Materials Science and Engineering Program,
University of Houston, Houston, Texas 77204, USA
| | - Yu Shrike Zhang
- Division of Engineering in Medicine, Department of
Medicine, Brigham and Women’s Hospital, Harvard Medical School, Cambridge,
Massachusetts 02139, USA
- Authors to whom correspondence should be addressed:
and
| | - Cunjiang Yu
- Authors to whom correspondence should be addressed:
and
| |
Collapse
|
15
|
Nault I, André P, Plourde B, Leclerc F, Sarrazin JF, Philippon F, O'Hara G, Molin F, Steinberg C, Roy K, Blier L, Champagne J. Validation of a novel single lead ambulatory ECG monitor – Cardiostat™ – Compared to a standard ECG Holter monitoring. J Electrocardiol 2019; 53:57-63. [DOI: 10.1016/j.jelectrocard.2018.12.011] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 12/12/2018] [Accepted: 12/18/2018] [Indexed: 10/27/2022]
|
16
|
Singh N, Moneghetti KJ, Christle JW, Hadley D, Plews D, Froelicher V. Heart Rate Variability: An Old Metric with New Meaning in the Era of using mHealth Technologies for Health and Exercise Training Guidance. Part One: Physiology and Methods. Arrhythm Electrophysiol Rev 2018; 7:193-198. [PMID: 30416733 PMCID: PMC6141929 DOI: 10.15420/aer.2018.27.2] [Citation(s) in RCA: 72] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Accepted: 06/19/2018] [Indexed: 11/04/2022] Open
Abstract
The autonomic nervous system plays a major role in optimising function of the cardiovascular (CV) system, which in turn has important implications for CV health. Heart rate variability (HRV) is a measurable reflection of this balance between sympathetic and parasympathetic tone and has been used as a marker for cardiac status and predicting CV outcomes. Recently, the availability of commercially available heart rate (HR) monitoring systems has had important CV health implications and permits ambulatory CV monitoring on a scale not achievable with traditional cardiac diagnostics. The focus of the first part of this two-part review is to summarise the physiology of HRV and to describe available technologies for HRV monitoring. Part two will present HRV measures for assessing CV prognosis and athletic training.
Collapse
Affiliation(s)
- Nikhil Singh
- Department of Medicine, University of Southern California Keck School of MedicineLos Angeles, CA, USA
| | - Kegan James Moneghetti
- Department of Medicine, St Vincent’s Hospital, University of MelbourneMelbourne, Australia
- The Division of Cardiovascular Medicine, Department of Medicine, Stanford School of MedicineStanford, CA, USA
| | - Jeffrey Wilcox Christle
- The Division of Cardiovascular Medicine, Department of Medicine, Stanford School of MedicineStanford, CA, USA
| | | | - Daniel Plews
- Sports Performance Research Institute New Zealand, AUT University, AUT-Millennium17 Antares Place, Mairangi Bay, New Zealand
| | - Victor Froelicher
- The Division of Cardiovascular Medicine, Department of Medicine, Stanford School of MedicineStanford, CA, USA
| |
Collapse
|
17
|
Lee SP, Ha G, Wright DE, Ma Y, Sen-Gupta E, Haubrich NR, Branche PC, Li W, Huppert GL, Johnson M, Mutlu HB, Li K, Sheth N, Wright JA, Huang Y, Mansour M, Rogers JA, Ghaffari R. Highly flexible, wearable, and disposable cardiac biosensors for remote and ambulatory monitoring. NPJ Digit Med 2018; 1:2. [PMID: 31304288 PMCID: PMC6550217 DOI: 10.1038/s41746-017-0009-x] [Citation(s) in RCA: 97] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Revised: 06/15/2017] [Accepted: 07/07/2017] [Indexed: 11/15/2022] Open
Abstract
Contemporary cardiac and heart rate monitoring devices capture physiological signals using optical and electrode-based sensors. However, these devices generally lack the form factor and mechanical flexibility necessary for use in ambulatory and home environments. Here, we report an ultrathin (~1 mm average thickness) and highly flexible wearable cardiac sensor (WiSP) designed to be minimal in cost (disposable), light weight (1.2 g), water resistant, and capable of wireless energy harvesting. Theoretical analyses of system-level bending mechanics show the advantages of WiSP’s flexible electronics, soft encapsulation layers and bioadhesives, enabling intimate skin coupling. A clinical feasibility study conducted in atrial fibrillation patients demonstrates that the WiSP device effectively measures cardiac signals matching the Holter monitor, and is more comfortable. WiSP’s physical attributes and performance results demonstrate its utility for monitoring cardiac signals during daily activity, exertion and sleep, with implications for home-based care. A highly flexible, low-power wearable sensor that harvests energy and monitors cardiac signals has been developed by Lee et al. The team was led by Dr. Roozbeh Ghaffari and co-workers at MC10 Inc. and Northwestern University’s Center for Bio-Integrated Electronics at the Simpson & Querrey Institute, in collaboration with the Massachusetts General Hospital and Tsinghua University. The novel wearable sensors measure cardiac signals comparable in signal fidelity to those achievable with expensive monitoring systems used in hospitals. Wearable health-care solutions are fundamentally changing the way we monitor our well-being at all times of the day, no matter whether we are asleep at home or busy at work. The sensors reported here are lightweight, inexpensive to manufacture, robust to everyday use, and capable of wireless data transmission and energy harvesting to and from a smartphone. The approach proved successful for measuring episodic electrocardiograms (ECG) and continuous heart rate signals with significantly higher patient comfort scores compared to standard Holter monitors in an initial pilot study conducted at the Massachusetts General Hospital (MGH).
Collapse
Affiliation(s)
| | - Grace Ha
- 2Massachusetts General Hospital, Boston, MA 02114 USA
| | | | - Yinji Ma
- 3AML, Department of Engineering Mechanics, Center for Mechanics and Materials, Tsinghua University, Beijing, 100084 China.,4Department of Civil and Environmental Engineering, Mechanical Engineering, and Materials Science and Engineering, Northwestern University, Evanston, IL 60208 USA
| | | | | | | | | | | | | | | | - Kan Li
- 4Department of Civil and Environmental Engineering, Mechanical Engineering, and Materials Science and Engineering, Northwestern University, Evanston, IL 60208 USA
| | | | | | - Yonggang Huang
- 4Department of Civil and Environmental Engineering, Mechanical Engineering, and Materials Science and Engineering, Northwestern University, Evanston, IL 60208 USA.,5Center for Bio-Integrated Electronics, Departments of Materials Science and Engineering, Biomedical Engineering, Chemistry, Mechanical Engineering, Electrical Engineering and Computer Science, and Neurological Surgery, Simpson Querrey Institute for Nano/Biotechnology, McCormick School of Engineering, Northwestern University, Evanston, IL 60208 USA
| | | | - John A Rogers
- 5Center for Bio-Integrated Electronics, Departments of Materials Science and Engineering, Biomedical Engineering, Chemistry, Mechanical Engineering, Electrical Engineering and Computer Science, and Neurological Surgery, Simpson Querrey Institute for Nano/Biotechnology, McCormick School of Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Roozbeh Ghaffari
- 1MC10 Inc, Lexington, MA 02421 USA.,5Center for Bio-Integrated Electronics, Departments of Materials Science and Engineering, Biomedical Engineering, Chemistry, Mechanical Engineering, Electrical Engineering and Computer Science, and Neurological Surgery, Simpson Querrey Institute for Nano/Biotechnology, McCormick School of Engineering, Northwestern University, Evanston, IL 60208 USA
| |
Collapse
|
18
|
Clinical Implications of Technological Advances in Screening for Atrial Fibrillation. Prog Cardiovasc Dis 2018; 60:550-559. [DOI: 10.1016/j.pcad.2018.01.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Accepted: 01/11/2018] [Indexed: 12/18/2022]
|
19
|
Trobec R, Tomašić I, Rashkovska A, Depolli M, Avbelj V. Commercial ECG Systems. BODY SENSORS AND ELECTROCARDIOGRAPHY 2018. [DOI: 10.1007/978-3-319-59340-1_6] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
|
20
|
Steinberg JS, Varma N, Cygankiewicz I, Aziz P, Balsam P, Baranchuk A, Cantillon DJ, Dilaveris P, Dubner SJ, El-Sherif N, Krol J, Kurpesa M, La Rovere MT, Lobodzinski SS, Locati ET, Mittal S, Olshansky B, Piotrowicz E, Saxon L, Stone PH, Tereshchenko L, Turitto G, Wimmer NJ, Verrier RL, Zareba W, Piotrowicz R. 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry. Heart Rhythm 2017; 14:e55-e96. [DOI: 10.1016/j.hrthm.2017.03.038] [Citation(s) in RCA: 159] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2017] [Indexed: 12/18/2022]
|
21
|
Steinberg JS, Varma N, Cygankiewicz I, Aziz P, Balsam P, Baranchuk A, Cantillon DJ, Dilaveris P, Dubner SJ, El‐Sherif N, Krol J, Kurpesa M, La Rovere MT, Lobodzinski SS, Locati ET, Mittal S, Olshansky B, Piotrowicz E, Saxon L, Stone PH, Tereshchenko L, Turitto G, Wimmer NJ, Verrier RL, Zareba W, Piotrowicz R. 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry. Ann Noninvasive Electrocardiol 2017; 22:e12447. [PMID: 28480632 PMCID: PMC6931745 DOI: 10.1111/anec.12447] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Accepted: 02/06/2017] [Indexed: 02/06/2023] Open
Abstract
Ambulatory ECG (AECG) is very commonly employed in a variety of clinical contexts to detect cardiac arrhythmias and/or arrhythmia patterns which are not readily obtained from the standard ECG. Accurate and timely characterization of arrhythmias is crucial to direct therapies that can have an important impact on diagnosis, prognosis or patient symptom status. The rhythm information derived from the large variety of AECG recording systems can often lead to appropriate and patient-specific medical and interventional management. The details in this document provide background and framework from which to apply AECG techniques in clinical practice, as well as clinical research.
Collapse
Affiliation(s)
- Jonathan S. Steinberg
- Heart Research Follow‐up ProgramUniversity of Rochester School of Medicine & DentistryRochesterNYUSA
- The Summit Medical GroupShort HillsNJUSA
| | - Niraj Varma
- Cardiac Pacing & ElectrophysiologyDepartment of Cardiovascular MedicineCleveland ClinicClevelandOHUSA
| | | | - Peter Aziz
- Cardiac Pacing & ElectrophysiologyDepartment of Cardiovascular MedicineCleveland ClinicClevelandOHUSA
| | - Paweł Balsam
- 1st Department of CardiologyMedical University of WarsawWarsawPoland
| | | | - Daniel J. Cantillon
- Cardiac Pacing & ElectrophysiologyDepartment of Cardiovascular MedicineCleveland ClinicClevelandOHUSA
| | - Polychronis Dilaveris
- 1st Department of CardiologyUniversity of Athens Medical SchoolHippokration HospitalAthensGreece
| | - Sergio J. Dubner
- Arrhythmias and Electrophysiology ServiceClinic and Maternity Suizo Argentina and De Los Arcos Private HospitalBuenos AiresArgentina
| | | | - Jaroslaw Krol
- Department of Cardiology, Hypertension and Internal Medicine2nd Medical Faculty Medical University of WarsawWarsawPoland
| | - Malgorzata Kurpesa
- Department of CardiologyMedical University of LodzBieganski HospitalLodzPoland
| | | | | | - Emanuela T. Locati
- Cardiovascular DepartmentCardiology, ElectrophysiologyOspedale NiguardaMilanoItaly
| | | | | | - Ewa Piotrowicz
- Telecardiology CenterInstitute of CardiologyWarsawPoland
| | - Leslie Saxon
- University of Southern CaliforniaLos AngelesCAUSA
| | - Peter H. Stone
- Vascular Profiling Research GroupCardiovascular DivisionHarvard Medical SchoolBrigham & Women's HospitalBostonMAUSA
| | - Larisa Tereshchenko
- Knight Cardiovascular InstituteOregon Health & Science UniversityPortlandORUSA
- Cardiovascular DivisionJohns Hopkins University School of MedicineBaltimoreMDUSA
| | - Gioia Turitto
- Weill Cornell Medical CollegeElectrophysiology ServicesNew York Methodist HospitalBrooklynNYUSA
| | - Neil J. Wimmer
- Vascular Profiling Research GroupCardiovascular DivisionHarvard Medical SchoolBrigham & Women's HospitalBostonMAUSA
| | - Richard L. Verrier
- Division of Cardiovascular MedicineBeth Israel Deaconess Medical CenterHarvard Medical SchoolHarvard‐Thorndike Electrophysiology InstituteBostonMAUSA
| | - Wojciech Zareba
- Heart Research Follow‐up ProgramUniversity of Rochester School of Medicine & DentistryRochesterNYUSA
| | - Ryszard Piotrowicz
- Department of Cardiac Rehabilitation and Noninvasive ElectrocardiologyNational Institute of CardiologyWarsawPoland
| |
Collapse
|
22
|
Fung E, Järvelin MR, Doshi RN, Shinbane JS, Carlson SK, Grazette LP, Chang PM, Sangha RS, Huikuri HV, Peters NS. Electrocardiographic patch devices and contemporary wireless cardiac monitoring. Front Physiol 2015; 6:149. [PMID: 26074823 PMCID: PMC4444741 DOI: 10.3389/fphys.2015.00149] [Citation(s) in RCA: 74] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2015] [Accepted: 04/27/2015] [Indexed: 01/19/2023] Open
Abstract
Cardiac electrophysiologic derangements often coexist with disorders of the circulatory system. Capturing and diagnosing arrhythmias and conduction system disease may lead to a change in diagnosis, clinical management and patient outcomes. Standard 12-lead electrocardiogram (ECG), Holter monitors and event recorders have served as useful diagnostic tools over the last few decades. However, their shortcomings are only recently being addressed by emerging technologies. With advances in device miniaturization and wireless technologies, and changing consumer expectations, wearable “on-body” ECG patch devices have evolved to meet contemporary needs. These devices are unobtrusive and easy to use, leading to increased device wear time and diagnostic yield. While becoming the standard for detecting arrhythmias and conduction system disorders in the outpatient setting where continuous ECG monitoring in the short to medium term (days to weeks) is indicated, these cardiac devices and related digital mobile health technologies are reshaping the clinician-patient interface with important implications for future healthcare delivery.
Collapse
Affiliation(s)
- Erik Fung
- Division of Cardiovascular Medicine, University of Southern California and Keck Medical Center of University of Southern California Los Angeles, CA, USA ; Department of Medicine, Geisel School of Medicine, Dartmouth College Hanover, NH, USA ; Department of Epidemiology and Biostatistics, Medical Research Council Health Protection Agency Centre for Environment and Health, School of Public Health, Imperial College London London, UK ; Digital Health Kitchen, Institute for Digital Health London, UK
| | - Marjo-Riitta Järvelin
- Department of Epidemiology and Biostatistics, Medical Research Council Health Protection Agency Centre for Environment and Health, School of Public Health, Imperial College London London, UK ; Faculty of Medicine, Center for Life Course Epidemiology, University of Oulu Oulu, Finland ; Biocenter Oulu, University of Oulu Oulu, Finland ; Unit of Primary Care, Oulu University Hospital Oulu, Finland
| | - Rahul N Doshi
- Division of Cardiovascular Medicine, University of Southern California and Keck Medical Center of University of Southern California Los Angeles, CA, USA
| | - Jerold S Shinbane
- Division of Cardiovascular Medicine, University of Southern California and Keck Medical Center of University of Southern California Los Angeles, CA, USA
| | - Steven K Carlson
- Division of Cardiovascular Medicine, University of Southern California and Keck Medical Center of University of Southern California Los Angeles, CA, USA
| | - Luanda P Grazette
- Division of Cardiovascular Medicine, University of Southern California and Keck Medical Center of University of Southern California Los Angeles, CA, USA
| | - Philip M Chang
- Division of Cardiovascular Medicine, University of Southern California and Keck Medical Center of University of Southern California Los Angeles, CA, USA ; Division of Cardiology, Children's Hospital Los Angeles Los Angeles, CA, USA
| | - Rajbir S Sangha
- Department of Medicine, Geisel School of Medicine, Dartmouth College Hanover, NH, USA ; Section of Cardiology, Dartmouth-Hitchcock Medical Center Lebanon, NH, USA
| | - Heikki V Huikuri
- Medical Research Center Oulu, Institute of Clinical Medicine, Oulu University Hospital and University of Oulu Oulu, Finland
| | - Nicholas S Peters
- Digital Health Kitchen, Institute for Digital Health London, UK ; National Heart and Lung Institute, Imperial College London, St Mary's and Hammersmith Hospitals London, UK
| |
Collapse
|
23
|
Cheung CC, Kerr CR, Krahn AD. Comparing 14-day adhesive patch with 24-h Holter monitoring. Future Cardiol 2015; 10:319-22. [PMID: 24976467 DOI: 10.2217/fca.14.24] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Barrett PM, Komatireddy R, Haaser S et al. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am. J. Med. 127(1), 95.e11–95.e17 (2014). The investigation of cardiac arrhythmias in the outpatient ambulatory setting has traditionally been initiated with the Holter monitor. Using the continuous recording over 24 or 48 h, the Holter monitor permits the detection of baseline rhythm, dysrhythmia and conduction abnormalities, including heart block and changes in the ST segment that may indicate myocardial ischemia. However, apart from the bulkiness and inconvenience of the device itself, the lack of extended monitoring results in a diagnostic yield of typically less than 20%. In this study by Barrett et al., 146 patients referred for the evaluation of cardiac arrhythmia were prospectively enrolled to wear both the 24-h Holter monitor and 14-day adhesive patch monitor (Zio Patch) simultaneously. The primary outcome was the detection of any one of six arrhythmias: supraventricular tachycardia, atrial fibrillation/flutter, pause >3 s, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/fibrillation. The adhesive patch monitor detected more arrhythmia events compared with the Holter monitor over the total wear time (96 vs. 61 events; p < 0.001), although the Holter monitor detected more events during the initial 24-h monitoring period (61 vs. 52 events; p = 0.013). Novel, single-lead, intermediate-duration, user-friendly adhesive patch monitoring devices, such as the Zio Patch, represent the changing face of ambulatory ECG monitoring. However, the loss of quality, automated rhythm analysis and inability to detect myocardial ischemia continue to remain important issues that will need to be addressed prior to the implementation of these new devices.
Collapse
Affiliation(s)
- Christopher C Cheung
- Arrhythmia Service, 9th Floor, Gordon & Leslie Diamond Health Care Centre, 2775 Laurel Street, Vancouver, BC V5Z 1M9, Canada
| | | | | |
Collapse
|
24
|
Tung CE, Su D, Turakhia MP, Lansberg MG. Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA. Front Neurol 2015; 5:266. [PMID: 25628595 PMCID: PMC4290477 DOI: 10.3389/fneur.2014.00266] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Accepted: 11/26/2014] [Indexed: 11/13/2022] Open
Abstract
Background: It is important to evaluate patients with transient ischemic attack (TIA) or stroke for atrial fibrillation (AF) because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch) in patients with stroke or TIA. Methods: We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies). Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented. Results: One thousand one hundred seventy-one monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2–14.0). The median analyzable time relative to the total wear time was 98.7% (IQR 96.0–99.5%). AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF) was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 h. The mean PAF burden was 12.7% of the total monitoring duration. Conclusion: Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 h of monitoring suggest that the cardiac patch is superior to conventional 48-h Holter monitors for AF detection in patients with stroke or TIA.
Collapse
Affiliation(s)
- Christie E Tung
- Department of Neurology, Stanford University , Palo Alto, CA , USA
| | - Derek Su
- Department of Neurology, Stanford University , Palo Alto, CA , USA
| | - Mintu P Turakhia
- Division of Cardiovascular Medicine, Department of Medicine, Stanford University , Palo Alto, CA , USA ; Veterans Affairs Palo Alto Health Care System , Palo Alto, CA , USA
| | | |
Collapse
|
25
|
Kwok CW, Treeck O, Buchholz S, Seitz S, Ortmann O, Engel JB. Receptors for luteinizing hormone-releasing hormone (GnRH) as therapeutic targets in triple negative breast cancers (TNBC). Target Oncol 2014; 10:365-73. [DOI: 10.1007/s11523-014-0340-y] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2014] [Accepted: 09/25/2014] [Indexed: 12/25/2022]
|
26
|
Precordial electrode placement for optimal ECG monitoring: Implications for ambulatory monitor devices and event recorders. J Electrocardiol 2014; 47:669-76. [DOI: 10.1016/j.jelectrocard.2014.04.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2013] [Indexed: 10/25/2022]
|
27
|
Turakhia MP, Hoang DD, Zimetbaum P, Miller JD, Froelicher VF, Kumar UN, Xu X, Yang F, Heidenreich PA. Diagnostic utility of a novel leadless arrhythmia monitoring device. Am J Cardiol 2013; 112:520-4. [PMID: 23672988 DOI: 10.1016/j.amjcard.2013.04.017] [Citation(s) in RCA: 152] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2013] [Revised: 04/08/2013] [Accepted: 04/08/2013] [Indexed: 11/28/2022]
Abstract
Although extending the duration of ambulatory electrocardiographic monitoring beyond 24 to 48 hours can improve the detection of arrhythmias, lead-based (Holter) monitors might be limited by patient compliance and other factors. We, therefore, evaluated compliance, analyzable signal time, interval to arrhythmia detection, and diagnostic yield of the Zio Patch, a novel leadless, electrocardiographic monitoring device in 26,751 consecutive patients. The mean wear time was 7.6 ± 3.6 days, and the median analyzable time was 99% of the total wear time. Among the patients with detected arrhythmias (60.3% of all patients), 29.9% had their first arrhythmia and 51.1% had their first symptom-triggered arrhythmia occur after the initial 48-hour period. Compared with the first 48 hours of monitoring, the overall diagnostic yield was greater when data from the entire Zio Patch wear duration were included for any arrhythmia (62.2% vs 43.9%, p <0.0001) and for any symptomatic arrhythmia (9.7% vs 4.4%, p <0.0001). For paroxysmal atrial fibrillation (AF), the mean interval to the first detection of AF was inversely proportional to the total AF burden, with an increasing proportion occurring after 48 hours (11.2%, 10.5%, 20.8%, and 38.0% for an AF burden of 51% to 75%, 26% to 50%, 1% to 25%, and <1%, respectively). In conclusion, extended monitoring with the Zio Patch for ≤14 days is feasible, with high patient compliance, a high analyzable signal time, and an incremental diagnostic yield beyond 48 hours for all arrhythmia types. These findings could have significant implications for device selection, monitoring duration, and care pathways for arrhythmia evaluation and AF surveillance.
Collapse
Affiliation(s)
- Mintu P Turakhia
- Veterans Affairs Palo Alto Health Care System, Palo Alto, CA, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|