1
|
Etcheverry M, Zanini GP. Kinetic study of paraquat adsorption on alginate beads loaded with montmorillonite using shrinking core model. Int J Biol Macromol 2024; 281:136515. [PMID: 39406329 DOI: 10.1016/j.ijbiomac.2024.136515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Revised: 09/19/2024] [Accepted: 10/10/2024] [Indexed: 10/19/2024]
Abstract
Water contamination by pesticides threatens clean water availability, highlighting the need for advanced sustainable sanitation systems. Adsorption using biopolymers and minerals is prominent. Understanding process kinetics and influencing parameters is crucial for optimizing contaminant-adsorbent contact time for safe water disposal. The adsorption kinetics of Paraquat (PQ) at three initial concentrations (C0 = 19, 38, and 50 ppm) were studied using alginate-montmorillonite (Alg-Mt) beads with varying clay contents and a 30-min gelation time. The beads were characterized by elemental analysis, TG/DTG, FTIR, XRD, SEM, and EDX. The Shrinking Core Model (SCM) was applied to the experimental data to determine if the diffusion of PQ within the beads depended on clay content. The effective diffusion coefficient (Dp) in the adsorbent increased from 7 × 10-12 to 1 × 10-10 m2 s-1 with increasing clay content, suggesting that diffusion into the interior depended on interaction with the mineral. This investigation also demonstrated that the synthesis of beads at different gelation times does not impact either the adsorption capacity or the adsorption rate of the herbicide on the materials. These results indicate that diffusion depends solely on the interaction of the cationic herbicide with the clay encapsulated within the bead hydrogel.
Collapse
Affiliation(s)
- Mariana Etcheverry
- Instituto de Química del Sur (INQUISUR), CONICET - Departamento de Química, Universidad Nacional del Sur (UNS), Av. Alem 1253, Bahía Blanca 8000, Argentina.
| | - Graciela P Zanini
- Instituto de Química del Sur (INQUISUR), CONICET - Departamento de Química, Universidad Nacional del Sur (UNS), Av. Alem 1253, Bahía Blanca 8000, Argentina.
| |
Collapse
|
2
|
Mansouri S. Recent developments of (bio)-sensors for detection of main microbiological and non-biological pollutants in plastic bottled water samples: A critical review. Talanta 2024; 274:125962. [PMID: 38537355 DOI: 10.1016/j.talanta.2024.125962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 02/27/2024] [Accepted: 03/20/2024] [Indexed: 05/04/2024]
Abstract
The importance of water in all biological processes is undeniable. Ensuring access to clean and safe drinking water is crucial for maintaining sustainable water resources. To elaborate, the consumption of water of inadequate quality can have a repercussion on human health. Furthermore, according to the instability of tap water quality, the consumption rate of bottled water is increasing every day at the global level. Although most people believe bottled water is safe, it can also be contaminated by microbiological or chemical pollution, which can increase the risk of disease. Over the last decades, several conventional analytical tools applied to analyze the contamination of bottled water. On the other hand, some limitations restrict their application in this field. Therefore, biosensors, as emerging analytical method, attract tremendous attention for detection both microbial and chemical contamination of bottled water. Biosensors enjoy several facilities including selectivity, affordability, and sensitivity. In this review, the developed biosensors for analyzing contamination of bottled water were highlighted, as along with working strategies, pros and cons of studies. Challenges and prospects were also examined.
Collapse
Affiliation(s)
- Sofiene Mansouri
- Department of Biomedical Technology, College of Applied Medical Sciences in Al-Kharj, Prince Sattam bin Abdulaziz University, Al-Kharj, 11942, Saudi Arabia; University of Tunis El Manar, Higher Institute of Medical Technologies of Tunis, Laboratory of Biophysics and Medical Technologies, Tunis, Tunisia.
| |
Collapse
|
3
|
Farokhvand N, Shareghi B, Farhadian S. Evidence for paraquat-pepsin interaction: In vitro and silico study. CHEMOSPHERE 2024; 349:140714. [PMID: 38006922 DOI: 10.1016/j.chemosphere.2023.140714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 10/03/2023] [Accepted: 11/12/2023] [Indexed: 11/27/2023]
Abstract
The use of the herbicide paraquat (PQ) has raised concerns about potential environmental consequences due to its toxicity and persistence in the environment. Considering the affinity of dangerous compounds to biological molecules, it is necessary to know their binding properties. This article focuses on the behavior of the pepsin enzyme following its contact with paraquat poison, and the interaction between paraquat and pepsin has been investigated in laboratory conditions and simulated physiological conditions using multispectral techniques. Fluorescence experiments showed that PQ uses a static method to quench pepsin's intrinsic fluorescence. By causing structural damage to pepsin, PQ may be detrimental as it alters its conformational function based on FT-IR spectroscopy. The coupling reaction is a spontaneous process caused by hydrogen bonding and van der Waals forces according to the analysis of the thermodynamic parameters of each system at three different temperatures. The molecular structure of pepsin changes when it binds to PQ. Also, the results showed that PQ is a pepsin inhibitor that changes the function of the enzyme.
Collapse
Affiliation(s)
- Najimeh Farokhvand
- Department of Biology, Faculty of Science, Shahrekord University, Shahrekord, P. O. Box.115, Iran
| | - Behzad Shareghi
- Department of Biology, Faculty of Science, Shahrekord University, Shahrekord, P. O. Box.115, Iran; Central Laboratory, Shahrekord University, Shahrekord, Iran.
| | - Sadegh Farhadian
- Department of Biology, Faculty of Science, Shahrekord University, Shahrekord, P. O. Box.115, Iran; Central Laboratory, Shahrekord University, Shahrekord, Iran.
| |
Collapse
|
4
|
Herrera-Domínguez M, Morales-Luna G, Mahlknecht J, Cheng Q, Aguilar-Hernández I, Ornelas-Soto N. Optical Biosensors and Their Applications for the Detection of Water Pollutants. BIOSENSORS 2023; 13:bios13030370. [PMID: 36979582 PMCID: PMC10046542 DOI: 10.3390/bios13030370] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 03/01/2023] [Accepted: 03/02/2023] [Indexed: 05/14/2023]
Abstract
The correct detection and quantification of pollutants in water is key to regulating their presence in the environment. Biosensors offer several advantages, such as minimal sample preparation, short measurement times, high specificity and sensibility and low detection limits. The purpose of this review is to explore the different types of optical biosensors, focusing on their biological elements and their principle of operation, as well as recent applications in the detection of pollutants in water. According to our literature review, 33% of the publications used fluorescence-based biosensors, followed by surface plasmon resonance (SPR) with 28%. So far, SPR biosensors have achieved the best results in terms of detection limits. Although less common (22%), interferometers and resonators (4%) are also highly promising due to the low detection limits that can be reached using these techniques. In terms of biological recognition elements, 43% of the published works focused on antibodies due to their high affinity and stability, although they could be replaced with molecularly imprinted polymers. This review offers a unique compilation of the most recent work in the specific area of optical biosensing for water monitoring, focusing on both the biological element and the transducer used, as well as the type of target contaminant. Recent technological advances are discussed.
Collapse
Affiliation(s)
- Marcela Herrera-Domínguez
- Tecnológico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Mexico
| | - Gesuri Morales-Luna
- Departamento de Física y Matemáticas, Universidad Iberoamericana, Prolongación Paseo de la Reforma 880, Mexico City 01219, Mexico
| | - Jürgen Mahlknecht
- Tecnológico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Mexico
| | - Quan Cheng
- Department of Chemistry, University of California, Riverside, CA 92521, USA
| | - Iris Aguilar-Hernández
- Tecnológico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Mexico
- Correspondence: (I.A.-H.); (N.O.-S.)
| | - Nancy Ornelas-Soto
- Tecnológico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Mexico
- Correspondence: (I.A.-H.); (N.O.-S.)
| |
Collapse
|
5
|
Zhang J, Xin PL, Wang XY, Chen HY, Li DW. Deep Learning-Based Spectral Extraction for Improving the Performance of Surface-Enhanced Raman Spectroscopy Analysis on Multiplexed Identification and Quantitation. J Phys Chem A 2022; 126:2278-2285. [PMID: 35380835 DOI: 10.1021/acs.jpca.1c10681] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Surface-enhanced Raman spectroscopy (SERS) has been recognized as a promising analytical technique for its capability of providing molecular fingerprint information and avoiding interference of water. Nevertheless, direct SERS detection of complicated samples without pretreatment to achieve the high-efficiency identification and quantitation in a multiplexed way is still a challenge. In this study, a novel spectral extraction neural network (SENN) model was proposed for synchronous SERS detection of each component in mixed solutions using a demonstration sample containing diquat dibromide (DDM), methyl viologen dichloride (MVD), and tetramethylthiuram disulfide (TMTD). A SERS spectra dataset including 3600 spectra of DDM, MVD, TMTD, and their mixtures was first constructed to train the SENN model. After the training step, the cosine similarity of the SENN model can achieve 0.999, 0.997, and 0.994 for DDM, MVD, and TMTD, respectively, which means that the spectra extracted from the mixture are highly consistent with those collected by the SERS experiment of the corresponding pure samples. Furthermore, a convolutional neural network model for quantitative analysis is combined with the SENN, which can simultaneously and rapidly realize the qualitative and quantitative SERS analysis of mixture solutions with lower than 8.8% relative standard deviation. The result demonstrates that the proposed strategy has great potential in improving SERS analysis in environmental monitoring, food safety, and so on.
Collapse
Affiliation(s)
- Jie Zhang
- Key Laboratory for Advanced Materials, Shanghai Key Laboratory of Functional Materials Chemistry, Frontiers Science Center for Materiobiology & Dynamic Chemistry, School of Chemistry & Molecular Engineering, East China University of Science and Technology, Shanghai 200237, P. R. China
| | - Pei-Lin Xin
- Key Laboratory for Advanced Materials, Shanghai Key Laboratory of Functional Materials Chemistry, Frontiers Science Center for Materiobiology & Dynamic Chemistry, School of Chemistry & Molecular Engineering, East China University of Science and Technology, Shanghai 200237, P. R. China
| | - Xiao-Yuan Wang
- Key Laboratory for Advanced Materials, Shanghai Key Laboratory of Functional Materials Chemistry, Frontiers Science Center for Materiobiology & Dynamic Chemistry, School of Chemistry & Molecular Engineering, East China University of Science and Technology, Shanghai 200237, P. R. China
| | - Hua-Ying Chen
- Key Laboratory for Advanced Materials, Shanghai Key Laboratory of Functional Materials Chemistry, Frontiers Science Center for Materiobiology & Dynamic Chemistry, School of Chemistry & Molecular Engineering, East China University of Science and Technology, Shanghai 200237, P. R. China
| | - Da-Wei Li
- Key Laboratory for Advanced Materials, Shanghai Key Laboratory of Functional Materials Chemistry, Frontiers Science Center for Materiobiology & Dynamic Chemistry, School of Chemistry & Molecular Engineering, East China University of Science and Technology, Shanghai 200237, P. R. China
| |
Collapse
|
6
|
Zhu M, Tang J, Shi T, Ma X, Wang Y, Wu X, Li H, Hua R. Uptake, translocation and metabolism of imidacloprid loaded within fluorescent mesoporous silica nanoparticles in tomato (Solanum lycopersicum). ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2022; 232:113243. [PMID: 35093815 DOI: 10.1016/j.ecoenv.2022.113243] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 01/17/2022] [Accepted: 01/24/2022] [Indexed: 06/14/2023]
Abstract
Fluorescence-labeling technology has been widely used for rapid detection of pesticides in agricultural production. However, there are few studies on the use of this technology to investigate pesticide uptake and transport in plants with fluorescent nanoparticle formulations. Here, we investigated uptake, transport, accumulation and metabolism of imidacloprid loaded in fluorescent mesoporous SiO2 nanoparticles (Im@FL-MSNs) in tomato plants, and compared the results with the pesticide application in granular formulation. The results revealed that Im@FL-MSNs applied via root uptake and foliar spray both could effectively transport in tomato plants and carry the imidacloprid to plant tissues. Neither Im@FL-MSNs nor imidacloprid was detected inside of tomato fruits from root uptake or foliar spray applications. Compared with the foliar application of granular formulation, imidacloprid in Im@FL-MSNs demonstrated a higher concentration in leaves (1.14 ± 0.07 mg/kg > 1.08 ± 0.04 mg/kg, 1.13 ± 0.09 mg/kg > 1.11 ± 0.02 mg/kg), longer half-life (0.84 d < 1.31 d, 0.90 d < 1.36 d) and small numbers of metabolites formed. These results suggest that mesoporous silica nanoparticles could serve as an effective and efficient pesticide carrier for achieving the high use efficiency in plant protection. The information is also helpful to guide the pesticide applications and assess the risks associated with environmental quality and dietary consumption of vegetables.
Collapse
Affiliation(s)
- Meiqing Zhu
- Key Laboratory of Agri-Food Safety of Anhui Province, School of Resources and Environment, Anhui Agricultural University, No. 130 Changjiang West Road, Hefei 230036, China; School of Chemical and Environmental Engineering, Anhui Polytechnic University, Wuhu, Anhui 241000, China
| | - Jun Tang
- Key Laboratory of Agri-Food Safety of Anhui Province, School of Resources and Environment, Anhui Agricultural University, No. 130 Changjiang West Road, Hefei 230036, China
| | - Taozhong Shi
- Key Laboratory of Agri-Food Safety of Anhui Province, School of Resources and Environment, Anhui Agricultural University, No. 130 Changjiang West Road, Hefei 230036, China
| | - Xin Ma
- Key Laboratory of Agri-Food Safety of Anhui Province, School of Resources and Environment, Anhui Agricultural University, No. 130 Changjiang West Road, Hefei 230036, China
| | - Yi Wang
- Key Laboratory of Agri-Food Safety of Anhui Province, School of Resources and Environment, Anhui Agricultural University, No. 130 Changjiang West Road, Hefei 230036, China
| | - Xiangwei Wu
- Key Laboratory of Agri-Food Safety of Anhui Province, School of Resources and Environment, Anhui Agricultural University, No. 130 Changjiang West Road, Hefei 230036, China
| | - Hui Li
- Department of Plant, Soil and Microbial Sciences, Michigan State University, East Lansing, MI 48824, USA.
| | - Rimao Hua
- Key Laboratory of Agri-Food Safety of Anhui Province, School of Resources and Environment, Anhui Agricultural University, No. 130 Changjiang West Road, Hefei 230036, China.
| |
Collapse
|
7
|
3D structured biochip for label free determinations at the point-of-need. MICRO AND NANO ENGINEERING 2022. [DOI: 10.1016/j.mne.2022.100117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
8
|
Liu S, Huo Y, Deng S, Li G, Li S, Huang L, Ren S, Gao Z. A facile dual-mode aptasensor based on AuNPs@MIL-101 nanohybrids for ultrasensitive fluorescence and surface-enhanced Raman spectroscopy detection of tetrodotoxin. Biosens Bioelectron 2021; 201:113891. [PMID: 34999522 DOI: 10.1016/j.bios.2021.113891] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Revised: 12/11/2021] [Accepted: 12/13/2021] [Indexed: 01/01/2023]
Abstract
The development of ultrasensitive, reliable, and facile detection technologies for trace tetrodotoxin (TTX) is challenging. We presented a facile dual-mode aptamer-based biosensor (aptasensor) for ultrasensitive fluorescence and surface-enhanced Raman spectroscopy (SERS) detection of TTX by using gold nanoparticles (AuNPs)-embedded metal-organic framework (MOF) nanohybrids (AuNPs@MIL-101) because of their superior properties. A TTX-specific aptamer labelled with fluorescence and Raman reporter cyanine-3 (Cy3-aptamer) was selected as the recognition element and signal probe. Without immobilisation processing steps, Cy3-aptamers were effectively adsorbed onto the surface of AuNPs@MIL-101, thereby generating both fluorescence quenching and SERS enhancement. The preferential binding of TTX towards the Cy3-aptamer triggered the release of rigid Cy3-aptamer-TTX complexes from the AuNPs@MIL-101 surface, which resulted in recovered fluorescence signals and weakened SERS signals. Switched fluorescence and SERS intensities exhibited excellent linear relationships with logarithms of TTX concentrations of 0.01-300 ng/mL, and ultrahigh detection sensitivities of 6 and 8 pg/mL, respectively, were obtained. Furthermore, two quantitative detection approaches for TTX-spiked puffer fish and clam samples obtained satisfactory spiked recoveries and coefficient of variation (CV) values. Notably, the dual-mode aptasensor also successfully determined natural TTX-contaminated samples, showing excellent practical applications. The results indicated that this dual-mode measurement not only was ultrasensitive and simple but also markedly boosted analysis reliability and precision. This study is the first to propose a dual-mechanism AuNPs@MIL-101-based aptasensor for detection of trace TTX and provides a favourable pathway for developing multimode sensing platforms for various applications.
Collapse
Affiliation(s)
- Sha Liu
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, China
| | - Yapeng Huo
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, China
| | - Sumei Deng
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, China
| | - Guanghua Li
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, China
| | - Shuang Li
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, China
| | - Lei Huang
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, China
| | - Shuyue Ren
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, China.
| | - Zhixian Gao
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, China.
| |
Collapse
|
9
|
Angelopoulou M, Tzialla K, Voulgari A, Dikeoulia M, Raptis I, Kakabakos SE, Petrou P. Rapid Detection of Salmonella typhimurium in Drinking Water by a White Light Reflectance Spectroscopy Immunosensor. SENSORS 2021; 21:s21082683. [PMID: 33920297 PMCID: PMC8069642 DOI: 10.3390/s21082683] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 04/01/2021] [Accepted: 04/07/2021] [Indexed: 02/01/2023]
Abstract
Biosensors represent an attractive approach for fast bacteria detection. Here, we present an optical biosensor for the detection of Salmonella typhimurium lipopolysaccharide (LPS) and Salmonella bacteria in drinking water, based on white light reflectance spectroscopy. The sensor chip consisted of a Si die with a thin SiO2 layer on top that was transformed into a biosensor through the immobilization of Salmonella LPS. The optical setup included a reflection probe with seven 200 μm fibers, a visible and near-infrared light source, and a spectrometer. The six fibers at the reflection probe circumference were coupled with the light source and illuminated the biosensor chip vertically, whereas the central fiber collected the reflected light and guided it to the spectrometer. A competitive immunoassay configuration was adopted for the analysis. Accordingly, a mixture of LPS or bacteria solution, pre-incubated for 15 min, with an anti-Salmonella LPS antibody was pumped over the chip followed by biotinylated secondary antibody and streptavidin for signal enhancement. The binding of the free anti-Salmonella antibody to chip-immobilized LPS led to a shift of the reflectance spectrum that was inversely related to the analyte concentration (LPS or bacteria) in the calibrators or samples. The total assay duration was 15 min, and the detection limits achieved were 4 ng/mL for LPS and 320 CFU/mL for bacteria. Taking into account the low detection limits, the short analysis time, and the small size of the chip and instrumentation employed, the proposed immunosensor could find wide application for bacteria detection in drinking water.
Collapse
Affiliation(s)
- Michailia Angelopoulou
- Immunoassays/Immunosensors Lab, Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Centre for Scientific Research “Demokritos”, 15341 Aghia Paraskevi, Greece; (K.T.); (S.E.K.)
- Correspondence: (M.A.); (P.P.); Tel.: +30-2106503819 (M.A. & P.P.)
| | - Konstantina Tzialla
- Immunoassays/Immunosensors Lab, Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Centre for Scientific Research “Demokritos”, 15341 Aghia Paraskevi, Greece; (K.T.); (S.E.K.)
| | | | - Mary Dikeoulia
- Delta Foods S.A., 14565 Agios Stefanos, Greece; (A.V.); (M.D.)
| | | | - Sotirios Elias Kakabakos
- Immunoassays/Immunosensors Lab, Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Centre for Scientific Research “Demokritos”, 15341 Aghia Paraskevi, Greece; (K.T.); (S.E.K.)
| | - Panagiota Petrou
- Immunoassays/Immunosensors Lab, Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Centre for Scientific Research “Demokritos”, 15341 Aghia Paraskevi, Greece; (K.T.); (S.E.K.)
- Correspondence: (M.A.); (P.P.); Tel.: +30-2106503819 (M.A. & P.P.)
| |
Collapse
|
10
|
Ran J, Zhang L, Yao J, Wang S, Liang P, Dong N. Cucurbit[7]uril as a matrix solid-phase dispersion for the extraction of quaternary ammonium pesticides from vegetables and their determination using HPLC-UV. Food Chem 2021; 350:129236. [PMID: 33610850 DOI: 10.1016/j.foodchem.2021.129236] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 01/25/2021] [Accepted: 01/25/2021] [Indexed: 02/08/2023]
Abstract
Cucurbit[7]uril (Q[7]) was first used as a dispersant sorbent material in a matrix solid-phase dispersion for the simultaneous extraction of four quaternary ammonium pesticides from vegetables before analysis using high-performance liquid chromatography with UV detection. Q[7] exhibited a better selectivity and adsorption capability for these compounds, which is due to its ability to bind selectively organic molecules into its hydrophobic cavity and to form stable host-guest inclusion complexes. Various parameters affecting the extraction were investigated and optimized, such as sorbent/sample mass ratio, grinding time, rinsing and eluting conditions. Under optimized conditions, the proposed method exhibited a linear response in the concentration range of 1-100 μg·kg-1, satisfactory recoveries for eight types of vegetable samples (>70%), and high repeatability (RSD < 9.0%). The limits of quantification were between 0.43 μg·kg-1 and 0.99 μg·kg-1, which is nearly 50 times lower than the maximum residue limits established by the European Council.
Collapse
Affiliation(s)
- Jinfeng Ran
- School of Chemistry and Chemical Engineering, Guizhou University, Guiyang 550025, China
| | - Lingxue Zhang
- School of Chemistry and Chemical Engineering, Guizhou University, Guiyang 550025, China
| | - Jianmei Yao
- School of Chemistry and Chemical Engineering, Guizhou University, Guiyang 550025, China
| | - Shasha Wang
- School of Chemistry and Chemical Engineering, Guizhou University, Guiyang 550025, China
| | - Ping Liang
- School of Chemistry and Chemical Engineering, Guizhou University, Guiyang 550025, China
| | - Nan Dong
- School of Chemistry and Chemical Engineering, Guizhou University, Guiyang 550025, China; Key Laboratory of Macrocyclic and Supramolecular Chemistry of Guizhou Province, Guiyang 550025, China.
| |
Collapse
|
11
|
A simple cation exchange model to assess the competitive adsorption between the herbicide paraquat and the biocide benzalkonium chloride on montmorillonite. Colloids Surf A Physicochem Eng Asp 2021. [DOI: 10.1016/j.colsurfa.2020.125797] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
12
|
Specific recognition of cationic paraquat in environmental water and vegetable samples by molecularly imprinted stir-bar sorptive extraction based on monohydroxylcucurbit[7]uril-paraquat inclusion complex. Mikrochim Acta 2020; 187:578. [PMID: 32975594 DOI: 10.1007/s00604-020-04491-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 08/17/2020] [Indexed: 10/23/2022]
Abstract
Molecularly imprinted stir-bar coatings were created based on a hydroxylcucurbit[7]uril-paraquat inclusion complex. The inclusion complex that contained paraquat (PQ) as a template and monohydroxylcucurbit[7]uril ((OH)Q[7]) as a monomer was preassembled mainly through cavity inclusion interaction of (OH)Q[7] to form a one-dimensional self-assembly structure. The inclusion complex was anchored chemically on the surface of a glass stir bar with hydroxy-terminated poly(dimethylsiloxane) by the sol-gel technique to obtain a molecularly imprinted polymer-coated stir bar (MIP-SB). The molecularly imprinted coating showed specific adsorption for cationic PQ in aqueous media. Other quaternary amine compounds with a similar structure that coexisted in the solution, such as ethyl-viologen, diquat, and difenzoquat, were almost not extracted by the prepared MIP-SB. The sorptive capacity of the MIP-SB for PQ was nearly four times that of the non-imprinted stir bar (NIP-SB). The recognition mechanism indicated that the selectivity and extraction capacity resulted mainly from the imprinted cavity in the polymer that was formed by a one-dimensional assembly structure consisting of the (OH)Q[7]-PQ inclusion complex. The imprinted cavity was complementary to the PQ in shape, size, and functionality. A method to determine PQ in environmental water and vegetable samples was developed by combining MIP-SB sorptive extraction with HPLC-UV. The linear range was from 100 to 10,000 ng L-1 with a 8.2 ng L-1 detection limit for water samples and 0.02-0.85 mg kg-1 with a 0.005 mg kg-1 detection limit for vegetable samples. The limit of detection for both samples was lower than the EU-established maximum residual levels and that of other previously reported methods. The average recoveries were 70.0-96.1% with a relative standard deviation ≤ 7.6%, which showed the successful application in real sample analysis. Molecularly imprinted stir-bar coatings were created based on a hydroxylcucurbit[7]uril-paraquat (PQ) inclusion complex, which showed a specific recognition toward cationic PQ. A method to determine PQ in environmental water and vegetable samples was established by combining MIP-SB sorptive extraction with HPLC-UV.
Collapse
|
13
|
Long F, Zhang M, Yuan J, Du J, Ma A, Pan J. A simple, versatile, and automated pulse-diffusion-focusing strategy for sensitive milliliter-level-injection HILIC-MS/MS analysis of hydrophilic toxins. JOURNAL OF HAZARDOUS MATERIALS 2020; 392:122318. [PMID: 32092652 DOI: 10.1016/j.jhazmat.2020.122318] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 01/16/2020] [Accepted: 02/14/2020] [Indexed: 06/10/2023]
Abstract
The measurement of trace hydrophilic toxins in complex aqueous-rich matrices is a daunting challenge. To address this analytical bottleneck, pulse diffusion focusing (PDF), a novel sample injection technique for hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS), was developed. Theoretical and experimental investigations of the mechanism and key parameters revealed that the pulse-injection approach, assisted by solvent diffusion, efficiently solved the volume overload problem. This milliliter-level-injection HILIC-MS/MS technique was reported for the first time herein, and provided a significant enhancement in sensitivity compared to the conventional injection method, in addition to being an efficient approach to address the solvent incompatibility of off-line sample preparation and HILIC. The automated PDF-HILIC-MS/MS system was obtained by slightly modifying a commercial LC-MS/MS instrument in an easy and economical manner. The efficiency of the system was demonstrated through the detection of trace tetrodotoxin contents in plasma and urine samples. Low limits of detection (i.e., 0.65 and 2.2 ng·mL-1) were obtained using the simplified sample preparation method. The recoveries were in the range 91-113.3 % with intra-day and inter-day precisions of ≤9.6 %. Further experimental results proved the method to be versatile for various hydrophilic toxins.
Collapse
Affiliation(s)
- Fei Long
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China
| | - Mei Zhang
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China
| | - Jiahao Yuan
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China
| | - Juan Du
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China
| | - Ande Ma
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China.
| | - Jialiang Pan
- Department of Hygiene Detection Center, School of Public Health, Southern Medical University (Guangdong Provincial Key Laboratory of Tropical Disease Research), Guangzhou, Guangdong, China.
| |
Collapse
|
14
|
Anastasiadis V, Koukouvinos G, Petrou PS, Economou A, Dekker J, Harjanne M, Heimala P, Goustouridis D, Raptis I, Kakabakos SE. Multiplexed mycotoxins determination employing white light reflectance spectroscopy and silicon chips with silicon oxide areas of different thickness. Biosens Bioelectron 2020; 153:112035. [DOI: 10.1016/j.bios.2020.112035] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 01/03/2020] [Accepted: 01/16/2020] [Indexed: 02/06/2023]
|
15
|
Application of Organic-Inorganic Hybrids in Chemical Analysis, Bio- and Environmental Monitoring. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10041458] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Organic-inorganic hybrids (OIH) are considered to be a powerful platform for applications in many research and industrial fields. This review highlights the application of OIH for chemical analysis, biosensors, and environmental monitoring. A methodology toward metrological traceability measurement and standardization of OIH and demonstration of the role of mathematical modeling in biosensor design are also presented. The importance of the development of novel types of OIH for biosensing applications is highlighted. Finally, current trends in nanometrology and nanobiosensors are presented.
Collapse
|
16
|
Stavra E, Petrou PS, Koukouvinos G, Economou A, Goustouridis D, Misiakos K, Raptis I, Kakabakos SE. Fast, sensitive and selective determination of herbicide glyphosate in water samples with a White Light Reflectance Spectroscopy immunosensor. Talanta 2020; 214:120854. [PMID: 32278411 DOI: 10.1016/j.talanta.2020.120854] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 02/10/2020] [Accepted: 02/16/2020] [Indexed: 01/21/2023]
Abstract
An optical immunosensor based on White Light Reflectance Spectroscopy is described for the determination of the herbicide glyphosate in drinking water samples. The biosensor allows for the label-free real-time monitoring of biomolecular interactions taking place onto a SiO2/Si chip by transforming the shift in the reflected interference spectrum caused by the immunoreaction to effective biomolecular adlayer thickness. Glyphosate determination is accomplished by functionalizing the chip with a protein conjugate of the herbicide followed by a competitive immunoassay format. Prior to the assay, glyphosate derivatization in the calibrators and/or the samples was performed through reaction with succinic anhydride. Under the optimized assay protocol, a detection limit of 10 pg mL-1 was achieved. Recovery values ranging from 90.0 to 110% were determined in spiked bottled and tap water samples, demonstrating the accuracy of the method. In addition, the sensor could be regenerated and re-used for at least 14 times without statistically significant effect on the assay sensitivity and accuracy. The excellent analytical performance and short analysis time (approx. 25 min), combined with the small sensor size, should be helpful for the fast on-site determination of glyphosate in drinking water samples.
Collapse
Affiliation(s)
- Eleftheria Stavra
- Immunoassays-Immunosensors Lab, INRASTES, NCSR "Demokritos", 15341, Aghia Paraskevi, Greece; Analytical Chemistry Lab, Department of Chemistry, University of Athens, Panepistimiopolis, 15771, Zografou, Greece
| | - Panagiota S Petrou
- Immunoassays-Immunosensors Lab, INRASTES, NCSR "Demokritos", 15341, Aghia Paraskevi, Greece.
| | - Georgios Koukouvinos
- Immunoassays-Immunosensors Lab, INRASTES, NCSR "Demokritos", 15341, Aghia Paraskevi, Greece
| | - Anastasios Economou
- Analytical Chemistry Lab, Department of Chemistry, University of Athens, Panepistimiopolis, 15771, Zografou, Greece
| | | | - Konstantinos Misiakos
- Institute of Nanoscience & Nanotechnology, NCSR "Demokritos", 15341, Aghia Paraskevi, Greece
| | - Ioannis Raptis
- ThetaMetrisis S.A., Polydefkous 14, 12243 Egaleo, Greece
| | - Sotirios E Kakabakos
- Immunoassays-Immunosensors Lab, INRASTES, NCSR "Demokritos", 15341, Aghia Paraskevi, Greece
| |
Collapse
|
17
|
Li Y, Liu L, Kuang H, Xu C. Preparing monoclonal antibodies and developing immunochromatographic strips for paraquat determination in water. Food Chem 2019; 311:125897. [PMID: 31771914 DOI: 10.1016/j.foodchem.2019.125897] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 11/07/2019] [Accepted: 11/11/2019] [Indexed: 11/16/2022]
Abstract
Paraquat (PQ) poisoning is a serious threat to human health that leads to pulmonary toxicity, neurotoxicity, and inflammation. Protecting humans from PQ exposure requires the development of rapid analytical methods for on-site detection. Here, two monoclonal antibodies against PQ were generated and an immunochromatographic assay (ICA) was exploited to determine PQ concentrations in water samples. The results showed that the monoclonal antibody 1D6 exhibited higher affinity and sensitivity, with an affinity constant of 5.4 × 108 mol/L and a limit of detection as low as 0.02 ng/mL. Without sample pretreatment, the developed ICA method provided visible limits of detection ranging from 0.25 to 1 ng/mL, and cut-off limits ranging from 1 to 5 ng/mL, where average recoveries were between 83.15% ± 1.9% and 94.49% ± 2.45% with a coefficient of variation ranging from 1.40% to 7.37%. Importantly, these observations were consistent with liquid chromatography tandem mass spectrometry. These data and results suggested that the ICA method was a reliable, portable, and high-throughput method for determining PQ residues in water samples.
Collapse
Affiliation(s)
- Yue Li
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China; International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Liqiang Liu
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China; International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Hua Kuang
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China; International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China
| | - Chuanlai Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China; International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China.
| |
Collapse
|
18
|
Possibilities and Prospects of Immunosensors for a Highly Sensitive Pesticide Detection in Vegetables and Fruits: a Review. FOOD ANAL METHOD 2019. [DOI: 10.1007/s12161-019-01630-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
19
|
Electrochemical detection of paraquat based on silver nanoparticles/water-soluble pillar[5]arene functionalized graphene oxide modified glassy carbon electrode. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.113221] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
20
|
Amouzadeh Tabrizi M, Ferré-Borrull J, Marsal LF. Highly sensitive aptasensor based on interferometric reflectance spectroscopy for the determination of amyloid β as an Alzheimer's disease biomarkers using nanoporous anodic alumina. Biosens Bioelectron 2019; 137:279-286. [PMID: 31125817 DOI: 10.1016/j.bios.2019.04.050] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 04/08/2019] [Accepted: 04/23/2019] [Indexed: 02/06/2023]
Abstract
It is well known that Alzheimer's disease is one of the global challenges for the 21st century. Therefore, it is urgent to develop a reliable biosensor for the detection of this disease. Here in, we have developed for the first time, an aptasensor based on interferometric reflectance spectroscopy (IRS) for the determination of amyloid β (Aβ) oligomers that is an Alzheimer's disease biomarker. For this purpose, the nanoporous anodic alumina (NAA) was first fabricated. After that, the pore walls of the NAA were modified with (3-aminopropyl) trimethoxysilane (NAA-NH2). The amino-terminal aptamers probe were then attached to the pore walls of the NAA-NH2 by using glutaraldehyde (GA) as the cross-linking agent. Subsequently, methylene blue (MB) was immobilized into the aptamer as the photo-probe, generating the MB/G-quadruplex complex. Since MB has a high absorption coefficient, the intensity of the reflected white light to the charge-coupled device (CCD) detector decreased. In the presence of the Aβ oligomers that have high affinity to the immobilized aptamer, the MB/quadruplex complex broke and MB washed away from the aptasensor. Therefore, the intensity of the reflected white light to the CCD detector increased. The increased signal intensity of the aptasensor has a logarithmic relationship with the concentration of Aβ oligomers. The proposed aptasensor exhibited a good response to the concentration of Aβ oligomers in the range of 0.5-50.0 μg × mL-1. The experimental detection limit was of 0.02 μg × mL-1 (at 3σ/S). The proposed optical aptasensor exhibited good selectivity, linear range, and stability.
Collapse
Affiliation(s)
- Mahmoud Amouzadeh Tabrizi
- Departamento de Ingeniería Electrónica, Eléctrica y Automática, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
| | - Josep Ferré-Borrull
- Departamento de Ingeniería Electrónica, Eléctrica y Automática, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain
| | - Lluis F Marsal
- Departamento de Ingeniería Electrónica, Eléctrica y Automática, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007 Tarragona, Spain.
| |
Collapse
|