1
|
Nonaka K, Teramae M, Pezzotti G. Effect of rapid cooling on residual stress and surface fracture toughness of dental zirconia. J Mech Behav Biomed Mater 2024; 157:106656. [PMID: 39033559 DOI: 10.1016/j.jmbbm.2024.106656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Revised: 06/24/2024] [Accepted: 07/07/2024] [Indexed: 07/23/2024]
Abstract
Short-time sintering of dental zirconia not only improves manufacturing efficiency of zirconia prosthetics, but also enables an attractive situation in which prosthetic treatment can be completed within a single visit. Although many studies have clarified the effects of heating rate and dwell time on the properties of dental zirconia during short-time sintering, there are only a few studies on rapid cooling. In this study, we investigated the effect of cooling rate on dental zirconia. It was found that the cooling rate had no effect on the three-point flexural strength, but a fast cooling rate improved fracture toughness at the material surface. Raman piezo-spectroscopy showed that a compressive stress layer formed in the neighborhood of the zirconia surface and that its thickness increased with increasing cooling rate. From the above results, it was concluded that the compressive stress layer formed on the surface by rapid cooling improved the apparent fracture toughness at the material surface.
Collapse
Affiliation(s)
- Kazumichi Nonaka
- Department of Research and Development, SHOFU INC., Higashiyama-ku, Kyoto, Japan.
| | - Mitsuji Teramae
- Department of Research and Development, SHOFU INC., Higashiyama-ku, Kyoto, Japan
| | - Giuseppe Pezzotti
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto, Japan; Department of Molecular Genetics, Institute of Biomedical Science, Kansai Medical University, Osaka, 573-1010, Japan
| |
Collapse
|
2
|
Chai H, Russ J, Vardhaman S, Lim CH, Zhang Y. A Bilayer Method for Measuring Toughness and Strength of Dental Ceramics. J Dent Res 2024; 103:419-426. [PMID: 38410925 DOI: 10.1177/00220345231225445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024] Open
Abstract
The ever-increasing usage of ceramic materials in restorative dentistry necessitates a simple and effective method to evaluate flexural strength σF and fracture toughness KC. We propose a novel method to determine these quantities using a bilayer specimen composed of a brittle plate adhesively bonded onto a transparent polycarbonate substrate. When this bilayer structure is placed under spherical indentation, tunneling radial cracks initiate and propagate in the lower surface of the brittle layer. The failure analysis is based on previous theoretical relationships, which correlate σF with the indentation force P and layer thickness d, and KC with P and mean length of radial cracks. This work examines the accuracy and limitations of this approach using a wide range of contemporary dental ceramic materials. The effect of layer thickness, indenter radius, load level, and length and number of radial cracks are carefully examined. The accuracy of the predicted σF and KC is similar to those obtained with other concurrent test methods, such as biaxial flexure and 3-point bending (σF), and bending specimens with crack-initiation flaws (KC). The benefits of the present approach include treatment for small and thin plates, elimination of the need to introduce a precrack, and avoidance of dealing with local material nonlinearity effects for the KC measurements. Finally, the bilayer configuration resembles occlusal loading of a ceramic restoration (brittle layer) bonded to a posterior tooth (compliant substrate).
Collapse
Affiliation(s)
- H Chai
- School of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel
| | - J Russ
- School of Dental Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - S Vardhaman
- Department of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA
- College of Dental Medicine, Columbia University, New York, NY, USA
| | - C H Lim
- Department of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA
| | - Y Zhang
- Department of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA
| |
Collapse
|
3
|
Yousry M, Hammad I, Halawani ME, Aboushelib M. Translucency of recent zirconia materials and material-related variables affecting their translucency: a systematic review and meta-analysis. BMC Oral Health 2024; 24:309. [PMID: 38443872 PMCID: PMC10913643 DOI: 10.1186/s12903-024-04070-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Accepted: 02/25/2024] [Indexed: 03/07/2024] Open
Abstract
BACKGROUND Recent forms of translucent zirconia material have been developed, offering a wide range of options and varieties for enhancing aesthetics, making it a preferred choice in the field of prosthetic dentistry. However, there is insufficient understanding regarding the recent types of zirconia materials and their optical behavior. Understanding the variables that influence the translucency of zirconia and identifying strategies to enhance its esthetics are crucial. PURPOSE The current systemic review highlights a comprehensive understanding of different zirconia generations in relation to their optical characteristics and evaluates material-related variables affecting their translucency. METHODS The present review studied in-vitro studies that evaluated the optical characteristics of different yttria content of yttria stabilized materials. The topics explored were: (1) the different zirconia material generations and their optical behavior; (2) material-related factors that affect their translucency. The research was restricted to online publication in the English language from July 1, 2010, to July 31, 2023, using PubMed, Scopus, and Science Direct resources. The search key terms and their combinations were "zirconia," "translucent zirconia," "cubic zirconia," "highly translucent zirconia," "yttria partially stabilized zirconia," "monolithic zirconia," "translucency," "optical properties," and "light transmission." RESULTS The data obtained from fifty-three studies addressed the optical characteristics of various zirconia generations. They reported that changing yttria content had a significant impact on translucency. Different kinds of zirconia ceramics of the same generation have varying translucencies. Achieving optimum aesthetics with monolithic zirconia is challenging due to factors related to material aspects such as the presence of additives, point defects, microstructure, thickness, phase distribution, and sintering conditions. CONCLUSIONS Newly developed monolithic dental zirconia ceramics have improved aesthetics and translucency. However, additional research is necessary to evaluate their performance and long-term durability. TRIAL REGISTRATION This systematic review was registered in PROSPERO, under number CRD42023474482.
Collapse
Affiliation(s)
- Mahinour Yousry
- Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| | - Ihab Hammad
- Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Mohamed El Halawani
- Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Moustafa Aboushelib
- Department of Dental Materials Science, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
4
|
Benalcazar Jalkh EB, Ramalho IS, Bergamo ETP, Alves LMM, Tanaka R, Witek L, Coelho PG, Hirata R, Bonfante EA. Ultrathin lithium disilicate and translucent zirconia crowns for posterior teeth: Survival and failure modes. J ESTHET RESTOR DENT 2024; 36:381-390. [PMID: 37676053 DOI: 10.1111/jerd.13127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 08/07/2023] [Accepted: 08/10/2023] [Indexed: 09/08/2023]
Abstract
PURPOSE To evaluate the reliability and failure modes of ultrathin (0.5 mm) lithium disilicate, translucent and ultra-translucent zirconia crowns for posterior teeth restorations. MATERIALS AND METHODS Fifty-four mandibular first molar crowns of three ceramic materials: (1) Lithium disilicate (e.max CAD, Ivoclar Vivadent), (2) 3Y-TZP (Zirconn Translucent, Vipi), and (3) 5Y-PSZ (Cercon XT, Dentsply Sirona), with 0.5 mm of thickness were milled and cemented onto composite resin abutments. Eighteen samples of each group were tested under mouth-motion step-stress accelerated life testing in a humid environment using mild, moderate, and aggressive profiles. Data was subjected to Weibull statistics. Use level curves were plotted and reliability was calculated for a given mission of 100,000 cycles at 100, 200, and 300 N. Fractographic analyses of representative samples were performed in scanning electron microscope. RESULTS Beta (β) values suggest that failures were dictated by material's strength for lithium disilicate and by fatigue damage accumulation for both zirconias. No significant differences were detected in Weibull modulus and characteristic strength among groups. At a given mission of 100,000 cycles at 100 N, lithium disilicate presented higher reliability (98% CB: 95-99) regarding 3Y-TZP and 5Y-PSZ groups (84% CB: 65%-93% and 79% CB: 37&-94%, respectively). At 200 N, lithium disilicate reliability (82% CB: 66%-91%) was higher than 5Y-PSZ (20% CB: 4%-44%) and not significantly different from 3Y-TZP (54% CB: 32%-72%). Furthermore, at 300 N no significant differences in reliability were detected among groups, with a notable reduction in the reliability of all materials. Fractographic analyses showed that crack initiated at the interface between the composite core and the ceramic crowns due to tensile stress generated at the intaglio surface. CONCLUSIONS Ultrathin lithium disilicate crowns demonstrated higher reliability relative to zirconia crowns at functional loads. Lithium disilicate and zirconia crown's reliability decreased significantly for missions at higher loads and similar failure modes were observed regardless of crown material. The indication of 0.5 mm thickness crowns in high-load bearing regions must be carefully evaluated. CLINICAL SIGNIFICANCE Ultraconservative lithium disilicate and zirconia crowns of 0.5 mm thickness may be indicated in anterior restorations and pre-molars. Their clinical indication in high-load requirement regions must be carefully evaluated.
Collapse
Affiliation(s)
- Ernesto B Benalcazar Jalkh
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
| | - Ilana S Ramalho
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
| | - Edmara T P Bergamo
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
- Biomaterials Division, New York University College of Dentistry, New York, New York, USA
- Department of Prosthodontics, New York University College of Dentistry, New York, New York, USA
| | - Larissa M M Alves
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
| | | | - Lukasz Witek
- Biomaterials Division, New York University College of Dentistry, New York, New York, USA
- Department of Biomedical Engineering, New York Univeristy Tandon School of Engineering, Brooklyn, New York, USA
| | - Paulo G Coelho
- DeWitt Daughtry Family Department of Surgery, Division of Plastic Surgery, University of Miami Miller School of Medicine, Miami, Florida, USA
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Ronaldo Hirata
- Biomaterials Division, New York University College of Dentistry, New York, New York, USA
| | - Estevam A Bonfante
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
| |
Collapse
|
5
|
Huang Y, Wang J, Zhu L, Liu L, Gao S. The optimal design and three-dimensional finite element analysis of CAD/CAM integrated roach attachment. Heliyon 2024; 10:e23283. [PMID: 38205291 PMCID: PMC10776949 DOI: 10.1016/j.heliyon.2023.e23283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 10/28/2023] [Accepted: 11/30/2023] [Indexed: 01/12/2024] Open
Abstract
Objectives To investigate the effect of different designs of movable parts and prosthetic materials on the stress distribution of supporting tissues in mandibular free end dentition defects using three-dimensional finite element analysis of digital Roach attachments. Material and methods A 3D model of a patient with Kennedy class I mandibular edentulous conditions was generated, and twelve prosthesis models were applied, combining two designs of removable parts and six types of CAD/CAM restorative materials with different elastic modulus (conventional zirconia, ultra-translucent zirconia, Polyetheretherketone (PEEK), Lithium disilicate, Nanoceramic resin, and resin composite (Paradigm MZ100, 3 M ESPE)). The stress distribution of abutment periodontal ligament, edentulousmucosa, and junction of attachment were analyzed using finite element analysis. Results The stress value of the buccal neck of the periodontal ligament and the maximum compressive stress of the distal periodontal ligament of the design with clasp arms were higher than those without clasp arms, while the stress on the junction of attachment and the displacement of the mucosa in the edentulous area were smaller. Restorative materials with high elastic modulus, such as conventional zirconia and ultra-translucent zirconia, are recommended to be used as the fixed part of Roach attachment. Conclusion CAD/CAM Roach attachments with clasp arms are recommended for the protection of mucosal soft tissue. Restorative materials with high elastic modulus, such as conventional zirconia and ultra-translucent zirconia, are recommended as the fixed part of Roach attachment for patients with free end defect of mandibular dentition. Clinical significance This study provides references for the design with clasp arms and the selection of clinical fixed-movable prosthetic materials. Clinicians should consider the design of attachments and selection of appropriate manufacturing materials carefully to avoid negative impacts on patients' periodontal support tissues.
Collapse
Affiliation(s)
- Yun Huang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Jingrong Wang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Liqing Zhu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Liren Liu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Shanshan Gao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| |
Collapse
|
6
|
Jurado CA, Afrashtehfar KI, Hyer J, Alhotan A. Effect of sintering on the translucency of CAD-CAM lithium disilicate restorations: A comparative in vitro study. J Prosthodont 2023; 32:861-866. [PMID: 36609993 DOI: 10.1111/jopr.13644] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 12/29/2022] [Accepted: 01/03/2023] [Indexed: 01/09/2023] Open
Abstract
PURPOSE The available independent data on the translucency of novel pre and fully sintered chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate are limited. This comparative in vitro study evaluated the translucency degree of pre and fully sintered chairside CAD-CAM lithium disilicate crowns after optional, required, and additional firing processes. MATERIALS AND METHODS One hundred and five maxillary left central incisor crowns manufactured by three different CAD-CAM lithium disilicate brands shade A1 were assigned into seven groups as follows (n = 15): (1) Straumann n!ce without sintering; (2) Straumann n!ce with one additional sintering process; (3) Straumann n!ce with two additional sintering processes; (4) Amber Mill with one sintering process; (5) Amber Mill with two sintering processes; (6) IPS e.max CAD with one sintering process; and (7) IPS e.max CAD with two sintering processes. The translucency of all crowns was evaluated with a color imaging spectrophotometer. All statistical analyses were performed using statistical software. A standard level of significance was set at α < 0.05. RESULTS All the milled crowns presented different degrees of translucency, and additional sintering processes altered it. IPS e.max CAD with two (4.33 ± 0.26) and one (4.01 ± 0.15) sintering processes displayed the highest translucency, whereas Straumann n!ce with no sintering process provided the lowest value (2.82 ± 0.16). CONCLUSIONS The translucency of chairside lithium disilicate single-unit full-coverage restorations manufactured with subtractive technology was significantly influenced by the brand and the number of sintering processes. The traditional presintered IPS e.max CAD and the fully crystallized glass-ceramic Straumann n!ce considerably increased the translucency after one additional firing process, whereas Amber Mill decreased its translucency.
Collapse
Affiliation(s)
- Carlos A Jurado
- Department of Prosthodontics, The University of Iowa College of Dentistry and Dental Clinics, Iowa City, Iowa, USA
| | - Kelvin I Afrashtehfar
- Clinical Sciences Department, College of Dentistry, Ajman University, Ajman City, UAE
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Jared Hyer
- A.T. Still University Arizona School of Dentistry and Oral Health, Mesa, Arizona, USA
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
7
|
Alghazzawi TF. A Comparison of Failure Loads for Polycrystalline Zirconia Ceramics with Varying Amounts of Yttria, Glass-Ceramics and Polymers in Two Different Test Conditions. Polymers (Basel) 2023; 15:4506. [PMID: 38231917 PMCID: PMC10708478 DOI: 10.3390/polym15234506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/14/2023] [Accepted: 11/21/2023] [Indexed: 01/19/2024] Open
Abstract
It is unclear how zirconia dental crowns with different yttria compositions will perform clinically, and how they will compare with crowns made of glass-ceramics and polymers. The present objective was to determine failure loads of crowns and discs made of glass ceramics or polymers as compared to yttria-partially stabilized zirconia (Y-PSZ) crowns and discs with varying yttria concentrations. Crowns of zirconia (Cercon XT, Katana UTML, BruxZir Anterior), glass ceramic (Celtra press, IPS e.max press, Lisi press), and polymeric materials (Trilor, Juvora, Pekkton) were fabricated and cemented to epoxy abutments. The total number of specimens was 135 for crowns and 135 for discs (n = 15 specimens per material type and design). A universal testing machine was used to perform compressive loading of crowns/discs to failure with a steel piston along the longitudinal axis of the abutments. Energy dispersive spectroscopy (EDS) was used to identify the yttria concentration for each zirconia brand. The data were analyzed using generalized linear models and regression analyses. The results revealed significant differences (p < 0.05) in mean failure loads for different crown materials: Trilor (6811 ± 960 N) > Juvora (5215 ± 151 N) > Cercon (4260 ± 520 N) = BruxZir (4186 ± 269 N) = e.max (3981 ± 384 N) > Katana (3195 ± 350 N) = Lisi (3173 ± 234 N) = Pekkton (3105 ± 398 N) > Celtra (2696 ± 393 N). The general linear model revealed significant differences (p < 0.05) in mean failure loads when comparing the different materials for the discs, i.e., Trilor (5456 ± 1748 N) > Juvora (4274 ± 869 N) > Pekkton (3771 ± 294 N) > Katana (2859 ± 527 N) > Cercon (2319 ± 342 N) = BuxZir (2250 ± 515 N) = e.max (2303 ± 721 N) = Lisi (2333 ± 535 N) > Celtra (1965 ± 659 N). EDS showed that the zirconia materials contained yttria at different concentrations (BruxZir = 5Y-PSZ, Cercon = 4Y-PSZ, Katana = 3Y-PSZ). The yttria concentration had a significant effect on the failure load of the Katana (3Y-PSZ) crowns, which revealed lower failure loads than the Cercon (4Y-PSZ) and BruxZir (5Y-PSZ) crowns, whose failure loads were comparable or higher than e.max glass ceramic. The failure load of the trilayer disc specimens did not correlate with the failure load of the respective crown specimens for the zirconia, glass-ceramic and polymeric materials.
Collapse
Affiliation(s)
- Tariq F. Alghazzawi
- Department of Substitutive Dental Sciences, Taibah University, Madinah 42353, Saudi Arabia;
- Department of Mechanical and Materials Engineering, The University of Alabama at Birmingham, Birmingham, AL 35294, USA
| |
Collapse
|
8
|
Kui A, Manziuc M, Petruțiu A, Buduru S, Labuneț A, Negucioiu M, Chisnoiu A. Translucent Zirconia in Fixed Prosthodontics-An Integrative Overview. Biomedicines 2023; 11:3116. [PMID: 38137337 PMCID: PMC10740999 DOI: 10.3390/biomedicines11123116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 11/12/2023] [Accepted: 11/15/2023] [Indexed: 12/24/2023] Open
Abstract
Over the past two decades, dental ceramics have experienced rapid advances in science and technology, becoming the fastest-growing field of dental materials. This review emphasizes the significant impact of translucent zirconia in fixed prosthodontics, merging aesthetics with strength, and highlights its versatility from single crowns to complex bridgework facilitated by digital manufacturing advancements. The unique light-conducting properties of translucent zirconia offer a natural dental appearance, though with considerations regarding strength trade-offs compared to its traditional, opaque counterpart. The analysis extends to the mechanical attributes of the material, noting its commendable fracture resistance and durability, even under simulated physiological conditions. Various zirconia types (3Y-TZP, 4Y-TZP, 5Y-TZP) display a range of strengths influenced by factors like yttria content and manufacturing processes. The study also explores adhesive strategies, underlining the importance of surface treatments and modern adhesives in achieving long-lasting bonds. In the realm of implant-supported restorations, translucent zirconia stands out for its precision, reliability, and aesthetic adaptability, proving suitable for comprehensive dental restorations. Despite its established benefits, the review calls for ongoing research to further refine the material's properties and adhesive protocols and to solidify its applicability through long-term clinical evaluations, ensuring its sustainable future in dental restorative applications.
Collapse
Affiliation(s)
- Andreea Kui
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Manuela Manziuc
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Adrian Petruțiu
- Oral Rehabilitation Department, Iuliu Hatieganu University of Medicine and Pharmacy, 13 Victor Babes Street, 400008 Cluj-Napoca, Romania
| | - Smaranda Buduru
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Anca Labuneț
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Marius Negucioiu
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| | - Andrea Chisnoiu
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (A.K.); (A.C.)
| |
Collapse
|
9
|
Pucci CR, Mafetano APVP, Borges ALS, de Andrade GS, Dal Piva AMDO, Kleverlaan CJ, Tribst JPM. Substrate Rigidity Effect on CAD/CAM Restorations at Different Thicknesses. Eur J Dent 2023; 17:1020-1028. [PMID: 36513340 PMCID: PMC10756807 DOI: 10.1055/s-0042-1757910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
OBJECTIVES This article evaluated the effect of substrates rigidities on the post-fatigue fracture resistance of adhesively cemented simplified restorations in lithium disilicate glass ceramic. METHODS Precrystalized computer-aided design/computer-aided manufacturing ceramic blocks were processed into disc-shaped specimens (n = 10, Ø = 10 mm), mimicking a simplified restoration at two thicknesses (0.5 and 1.0 mm). Thereafter, the discs were cemented onto different base substrates (dentin analogue [control], dentin analogue with a central core build-up of resin composite [RC], or glass ionomer cement [GIC]). The specimens were subjected to mechanical cycling in a chewing simulator (100 N, 1 × 106 cycles, 4 Hz) and then subjected to thermocycling aging (10,000 cycles, 5/37/55°C, 30 seconds). After the fatigue protocol, the specimens were loaded until failure (N) in a universal testing machine. Finite element analysis calculated the first principal stress at the center of the adhesive interface. RESULTS The results showed that "restoration thickness," "type of substrate," and their interaction were statistically significant (one-way analysis of variance; p < 0.001). Regardless the restoration thickness a higher fracture load was observed for specimens cemented to dentin analogue. Among the base materials, RC build-up presented the highest fracture load and lower stress magnitude for both restoration thicknesses in comparison with GIC build-up. The 0.5-mm restoration showed higher stress peak and lower fracture load when submitted to the compressive test. CONCLUSION More flexible base material reduces the fracture load and increases the stress magnitude of adhesively cemented lithium disilicate restorations regardless the ceramic thickness. Therefore, more rigid substrates are suggested to be used to prevent restoration mechanical failures.
Collapse
Affiliation(s)
- César Rogério Pucci
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, Brazil
| | - Ana Paula Valente Pinho Mafetano
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, Brazil
| | - Alexandre Luiz Souto Borges
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, Brazil
| | | | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - Cornelis J. Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - João Paulo Mendes Tribst
- Department of Oral Regenerative Medicine, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| |
Collapse
|
10
|
Choo SS, Ko KH, Huh YH, Park CJ, Cho LR. Fatigue resistance of anterior monolithic crowns produced from CAD-CAM materials: An in vitro study. J Prosthet Dent 2023; 130:620-628. [PMID: 34980473 DOI: 10.1016/j.prosdent.2021.09.034] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Revised: 09/29/2021] [Accepted: 09/29/2021] [Indexed: 10/19/2022]
Abstract
STATEMENT OF PROBLEM Lithium disilicate and 5 mol% yttria partially stabilized zirconia (5Y-PSZ) are commonly used for anterior restorations. However, studies comparing the durability of 5Y-PSZ and lithium disilicates are sparse. PURPOSE The purpose of this in vitro study was to investigate the fracture load of anterior monolithic crowns made of 2 lithium disilicates and a 5Y-PSZ under dynamic loading. MATERIAL AND METHODS Titanium abutments of the maxillary incisors were prepared (N=48, 8 for each group). Monolithic anterior crowns were made from the lithium disilicates (e.max CAD, Rosetta SM) and 5Y-PSZ (Katana UTML). After cementation, the specimens were stored in water for 24 hours and then thermocycled 10 000 times. Dynamic loading (70 N, 200 000 cycles, 1 Hz) was applied to half the specimens. The fracture load was measured by using a universal testing machine. The fracture patterns were analyzed and fractography applied. Two-way ANOVA and the Fisher exact test were used for statistical analysis (α=.05). RESULTS The material and dynamic loading affected the fracture load of the anterior monolithic crowns (P<.05). However, there was no interaction between the material and the dynamic loading (P=.079). Both lithium disilicates had higher fracture loads than 5Y-PSZ (P<.05). The fracture load of each specimen was reduced after dynamic loading (P<.05). Lithium disilicate showed marginal and bulk fractures, and 5Y-PSZ presented catastrophic fractures (P<.001). CONCLUSIONS 5Y-PSZ materials with large grains and low flexural strength may be less resistant to fractures under dynamic loading than lithium disilicates.
Collapse
Affiliation(s)
- Seung-Sik Choo
- Graduate student, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Kyung-Ho Ko
- Assistant Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Yoon-Hyuk Huh
- Associate Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Chan-Jin Park
- Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Lee-Ra Cho
- Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea.
| |
Collapse
|
11
|
Giugliano TS, Zhang Y, Janal MN, Lim CH, Smith RM, Choi M. In vitro comparison of physical characteristics of milled versus printed zirconia discs. J Prosthodont 2023:10.1111/jopr.13778. [PMID: 37776103 PMCID: PMC10980599 DOI: 10.1111/jopr.13778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 09/25/2023] [Accepted: 09/27/2023] [Indexed: 10/01/2023] Open
Abstract
PURPOSE The purpose of this study was to compare the dimensional accuracy, translucency, and biaxial flexural strength of milled zirconia (MZ) versus 3D-printed zirconia (PZ) discs. MATERIALS & METHODS A circular disc measuring 14.0 mm in diameter and 1.20 mm in thickness was designed using computer-aided design (CAD) software. The resulting standard tessellation language (STL) file was used both as a control and to fabricate 36 zirconia (3Y-TZP) disc specimens (n = 36): 18 were milled (group MZ) and 18 were 3D-printed (group PZ). The diameter and thickness of each disc were measured using a digital caliper. Translucency was evaluated using a calibrated dental colorimeter. The flexural strength was determined using the piston-on-three-ball biaxial flexure test. All measurements were done by one blinded examiner. The statistical significance level was set to α = 0.05. RESULTS The MZ discs had significantly more accurate dimensions than the PZ discs in both diameter and thickness when compared to the control CAD software-designed disc. The MZ discs exhibited significantly higher translucency (translucency parameter (TP) = 16.95 ±0.36 vs. 9.24 ±1.98) and biaxial flexural strength (996.16 ±137.37 MPa vs. 845.75 ±266.16 MPa) than the PZ discs. Finally, MZ possessed a significantly higher Weibull modulus relative to PZ. CONCLUSIONS The results showed that the milled specimens achieved better dimensional accuracy and were more translucent, stronger, and less prone to failure than printed specimens.
Collapse
Affiliation(s)
- Thomas S. Giugliano
- Department of Prosthodontics, New York University College of Dentistry, New York, NY
| | - Yu Zhang
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA
| | - Malvin N. Janal
- Department of Epidemiology & Health Promotion, New York University College of Dentistry, New York, NY
| | - Chek Hai Lim
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA
| | - Ruby M. Smith
- Post-Graduate Student, Department of Prosthodontics, New York University College of Dentistry, New York, NY
| | - Mijin Choi
- Department of Prosthodontics, New York University College of Dentistry, New York, NY
| |
Collapse
|
12
|
Capobianco V, Baroudi K, Santos MJMC, Rubo JH, Rizkalla AS, Dal Piva AMDO, Vitti RP, Tribst JPM, Santos GC. Post-fatigue fracture load, stress concentration and mechanical properties of feldspathic, leucite- and lithium disilicate-reinforced glass ceramics. Heliyon 2023; 9:e17787. [PMID: 37449193 PMCID: PMC10336509 DOI: 10.1016/j.heliyon.2023.e17787] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 06/09/2023] [Accepted: 06/28/2023] [Indexed: 07/18/2023] Open
Abstract
Objective To evaluate the mechanical properties of different CAD/CAM ceramic systems and the post-fatigue fracture and stress distribution when used as cemented crowns. Materials and methods Sixty (60) CAD/CAM monolithic crowns were milled using three different ceramic materials (FD - Feldspathic [Vita Mark II]), LE - Leucite-based ceramic [IPS Empress CAD] and LD - Lithium Disilicate [IPS e.max CAD]) and adhesively cemented on resin composite dyes. Specimens were stored in distillated water (37 °C) for 7 days. After, half of the crowns were submitted to immediate fracture load test while the other half was submitted to fatigue cycling. The average cement layer of approximately 80 μm was assessed using scanning electron microscopy (SEM). The average thickness was used in the three-dimensional (3D) Finite Element Analysis (FEA). For each ceramic material, the density, Poisson ratio, shear modulus, Young modulus, fracture toughness, and true hardness were assessed (n = 3). The data was used to assess the Maximum Principal Stress throughout 3D-FEA according to each material during load to fail and post-fatigue. Data were submitted to two-way ANOVA and Tukey test (α = 0.05). Results LD showed the highest compression load, density, shear modulus, Young modulus, fracture toughness and true hardness values. While LE presented the lowest mechanical properties values. There is no difference in the Poisson ratio between the evaluated ceramics. Conclusion LD was susceptible to aging process but presented stronger physicomechanical properties, showing the highest post-fatigue fracture load and highest stress magnitude.
Collapse
Affiliation(s)
| | - Kusai Baroudi
- RAK College of Dental Sciences, RAK Medical & Health Sciences University, RAS Al Khaimah, United Arab Emirates
- School of Dentistry, University of Taubaté, Taubaté, SP, Brazil
| | | | | | - Amin S. Rizkalla
- Schulich School of Medicine & Dentistry, The University of Western Ontario, London, ON, Canada
| | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials, Academic Centre for Dentistry Amsterdam (ACTA),Universiteit van Amsterdam en Vrije Universiteit, Amsterdam, the Netherlands
| | - Rafael Pino Vitti
- School of Dentistry, Herminio Ometto University Center, Araras, SP, Brazil
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA),Universiteit van Amsterdam en Vrije Universiteit, Amsterdam, the Netherlands
| | - Gildo Coelho Santos
- Schulich School of Medicine & Dentistry, The University of Western Ontario, London, ON, Canada
| |
Collapse
|
13
|
Athab Hasan S, Mohammed-Hussain Abdul-Ameer Z. Effect of three different preparation designs on the marginal adaptation of indirect overlay restoration fabricated from lithium disilicate ceramic material: An in-vitro comparative study. Saudi Dent J 2023; 35:372-377. [PMID: 37251711 PMCID: PMC10213839 DOI: 10.1016/j.sdentj.2023.03.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 03/12/2023] [Accepted: 03/29/2023] [Indexed: 05/31/2023] Open
Abstract
Objectives Marginal adaptation is considered one of the key factors influencing the success of indirect restorations. This study aimed to estimate the marginal fit of lithium disilicate overlays with three distinct preparation designs before and after cementation. Methods Thirty maxillary first premolars were divided into the hollow chamfer design (HCD) group, butt-joint design (BJD) group, and conventional occlusal box design (COD) group (n = 10 each). The samples were scanned using an intra-oral scanner, and overlays were fabricated using computer-assisted design and milled on a computer-assisted machine. The finished restorations were luted using a self-adhesive resin RelyX Ultimate. The marginal gap was assessed using a digital microscope with 230X magnification power. Statistical analysis was conducted using analysis of variance and post hoc (Bonferroni correction) tests, assuming a significance level of 5%. Results The HCD and BJD groups recorded significantly lower marginal gap, (11.39 ± 0.72, 16.29 ± 0.75) and (11.59 ± 0.75, 16.93 ± 0.65) respectively, than the COD group (24.57 ± 1.18, 34.45 ± 1.09) both pre- and post-cementation. Conclusion This study demonstrated that modification of tooth preparation plays a significant role in the marginal adaptation of the lithium disilicate overlays. The gap was smaller with the HCD and BJD than with the COD, with a statistically significant difference.
Collapse
Affiliation(s)
- Sajad Athab Hasan
- Corresponding author at: Aesthetic and Restorative Dentistry Department, College of Dentistry, University of Baghdad, Altibbi Collection, Bab Al Muadham, Zip Code 10049-10047, Al Rusafa, Baghdad, Iraq.
| | | |
Collapse
|
14
|
Abstract
The purpose of this article is to review current understanding of lithia-based glass-ceramics and to identify future research needs for this class of dental materials in relation to novel compositions and fabrication methods. With rapid advances in material development and digital technology, time efficiency of dental workflow and fit accuracy of ceramic restorations are ever improving. Lithia-based glass-ceramics are at the forefront of this advance-new variants with more efficient fabrication routes are continually being introduced into the marketplace. Base glass composition, crystallization heat treatment, nucleant and coloration additives, and property gradation are some pertinent variables. The trend in fabrication is to move from CAD/CAM grinding of partially crystallized glass-ceramics to fully crystallized materials, thereby circumventing the need for postmachining firing altogether. In these endeavors, a better understanding of mechanical properties and evolving shaping technologies, such as ductile grinding, is paramount. Additive manufacturing and 3-dimensional printing methodologies offer a promising alternative to current CAD/CAM subtractive manufacturing routes. Challenges to the implementation of new technologies in efficient development and production of high-quality dental glass-ceramic prostheses are addressed.
Collapse
Affiliation(s)
- Y. Zhang
- Department of Preventive and
Restorative Sciences, School of Dental Medicine, University of Pennsylvania,
Philadelphia, PA, USA
| | - S. Vardhaman
- Department of Preventive and
Restorative Sciences, School of Dental Medicine, University of Pennsylvania,
Philadelphia, PA, USA
| | - C.S. Rodrigues
- Department of Dental Materials and
Prosthodontics, Institute of Science and Technology, São Paulo State University, São
José dos Campos, Brazil
| | - B.R. Lawn
- Material Measurement Laboratory,
National Institute of Standards and Technology, Gaithersburg, MD, USA
| |
Collapse
|
15
|
Fidalgo-Pereira R, Torres O, Carvalho Ó, Silva FS, Catarino SO, Özcan M, Souza JCM. A Scoping Review on the Polymerization of Resin-Matrix Cements Used in Restorative Dentistry. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1560. [PMID: 36837188 PMCID: PMC9961405 DOI: 10.3390/ma16041560] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 02/08/2023] [Accepted: 02/09/2023] [Indexed: 06/18/2023]
Abstract
In dentistry, clinicians mainly use dual-cured or light-cured resin-matrix cements to achieve a proper polymerization of the organic matrix leading to enhanced physical properties of the cement. However, several parameters can affect the polymerization of resin-matrix cements. The main aim of the present study was to perform a scoping review on the degree of conversion (DC) of the organic matrix, the polymerization, and the light transmittance of different resin-matrix cements used in dentistry. A search was performed on PubMed using a combination of the following key terms: degree of conversion, resin cements, light transmittance, polymerization, light curing, and thickness. Articles in the English language published up to November 2022 were selected. The selected studies' results demonstrated that restorative structures with a thickness higher than 1.5 mm decrease the light irradiance towards the resin-matrix cement. A decrease in light transmission provides a low energy absorption through the resin cement leading to a low DC percentage. On the other hand, the highest DC percentages, ranging between 55 and 75%, have been reported for dual-cured resin-matrix cements, although the polymerization mode and exposure time also influence the DC of monomers. Thus, the polymerization of resin-matrix cements can be optimized taking into account different parameters of light-curing, such as adequate light distance, irradiance, exposure time, equipment, and wavelength. Then, optimum physical properties are achieved that provide a long-term clinical performance of the cemented restorative materials.
Collapse
Affiliation(s)
- Rita Fidalgo-Pereira
- University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal
- Center for Interdisciplinary Research in Health (CIIS), Faculty of Dental Medicine (FMD), Universidade Católica Portuguesa (UCP), 3504-505 Viseu, Portugal
| | - Orlanda Torres
- University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal
| | - Óscar Carvalho
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058 Guimarães, Portugal
- LABBELS Associate Laboratory, University of Minho, 4805-017 Guimarães, Portugal
| | - Filipe S. Silva
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058 Guimarães, Portugal
- LABBELS Associate Laboratory, University of Minho, 4805-017 Guimarães, Portugal
| | - Susana O. Catarino
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058 Guimarães, Portugal
- LABBELS Associate Laboratory, University of Minho, 4805-017 Guimarães, Portugal
| | - Mutlu Özcan
- Division of Dental Biomaterials, Center of Dental Medicine, Clinic of Reconstructive Dentistry, University of Zurich, 8032 Zurich, Switzerland
| | - Júlio C. M. Souza
- University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058 Guimarães, Portugal
- LABBELS Associate Laboratory, University of Minho, 4805-017 Guimarães, Portugal
| |
Collapse
|
16
|
Darwich MA, Aljareh A, Alhouri N, Szávai S, Nazha HM, Duvigneau F, Juhre D. Biomechanical Assessment of Endodontically Treated Molars Restored by Endocrowns Made from Different CAD/CAM Materials. MATERIALS (BASEL, SWITZERLAND) 2023; 16:764. [PMID: 36676500 PMCID: PMC9864025 DOI: 10.3390/ma16020764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 01/03/2023] [Accepted: 01/11/2023] [Indexed: 06/17/2023]
Abstract
The aim of this study was to evaluate the deflection and stress distribution in endodontically treated molars restored by endocrowns from different materials available for the computer-aided design/computer-aided manufacturing (CAD/CAM) technique using three-dimensional finite element analysis. The models represented extensively damaged molars restored by endocrowns from the following materials: translucent zirconia; zirconia-reinforced glass ceramic; lithium disilicate glass ceramic; polymer-infiltrated ceramic network (PICN) and resin nanoceramic. Axial and oblique loadings were applied and the resulting stress distribution and deflection were analyzed. The Mohr-Coulomb (MC) ratio was also calculated in all models. The translucent zirconia endocrown showed the highest stress concentration within it and the least stress in dental structures. The resin nanoceramic model was associated with the greatest stress concentration in dental tissues, followed by the PICN model. Stress was also concentrated in the distal region of the cement layer. The MC ratio in the cement was higher than 1 in the resin nanoceramic model. Oblique loading caused higher stresses in all components and greater displacement than axial loading, whatever the material of the endocrown was. The translucent zirconia model recorded deflections of enamel and dentin (38.4 µm and 35.7 µm, respectively), while resin nanoceramic showed the highest stress concentration and displacement in the tooth-endocrown complex.
Collapse
Affiliation(s)
- Mhd Ayham Darwich
- Faculty of Biomedical Engineering, Al-Andalus University for Medical Sciences, Tartous, Syria
- Faculty of Technical Engineering, University of Tartous, Tartous, Syria
| | - Abeer Aljareh
- Faculty of Dentistry, Damascus University, Damascus, Syria
| | - Nabil Alhouri
- Faculty of Dentistry, Damascus University, Damascus, Syria
| | - Szabolcs Szávai
- Faculty of Mechanical Engineering and Informatics, University of Miskolc, 3515 Miskolc, Hungary
| | - Hasan Mhd Nazha
- Faculty of Mechanical Engineering, Institute of Mechanics, Otto Von Guericke University Magdeburg, Universitätsplatz 2, 39106 Magdeburg, Germany
| | - Fabian Duvigneau
- Faculty of Mechanical Engineering, Institute of Mechanics, Otto Von Guericke University Magdeburg, Universitätsplatz 2, 39106 Magdeburg, Germany
| | - Daniel Juhre
- Faculty of Mechanical Engineering, Institute of Mechanics, Otto Von Guericke University Magdeburg, Universitätsplatz 2, 39106 Magdeburg, Germany
| |
Collapse
|
17
|
State of the Art of Different Zirconia Materials and Their Indications According to Evidence-Based Clinical Performance: A Narrative Review. Dent J (Basel) 2023; 11:dj11010018. [PMID: 36661555 PMCID: PMC9857458 DOI: 10.3390/dj11010018] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 12/21/2022] [Accepted: 12/27/2022] [Indexed: 01/06/2023] Open
Abstract
The aim of this study was to perform a narrative review to identify the modifications applied to the chemical structure of third- and fourth-generation zirconia ceramics and to determine the influence of these changes on the mechanical and optical properties. A bibliographical search using relevant keywords was conducted in the PubMed® and EBSCO databases. The abstracts and full texts of the resulting articles were reviewed for final inclusion. Fifty-four articles were included in this review. The analyzed topics were: (1) the composition of first- and second-generation zirconia materials (Y-TZP), (2) the behavior of the studied generations in relation to mechanical and optical properties, and (3) the modifications that were carried out on third-generation (5Y-TZP) and fourth-generation (4Y-TZP) zirconia materials. However, studies focusing on these specific characteristics in third- and fourth-generation zirconia materials are scarce. The review shows that there is a lack of sufficient knowledge about the chemical modifications of zirconia in the new generations.
Collapse
|
18
|
Cho MH, Seol HJ. Optical Properties, Microstructure, and Phase Fraction of Multi-Layered Monolithic Zirconia with and without Yttria-Gradient. MATERIALS (BASEL, SWITZERLAND) 2022; 16:41. [PMID: 36614380 PMCID: PMC9821384 DOI: 10.3390/ma16010041] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 12/12/2022] [Accepted: 12/19/2022] [Indexed: 06/17/2023]
Abstract
The differences in the optical properties of multi-layered zirconia with and without yttria-gradient are not fully understood. This study aimed to evaluate and compare the optical properties, related microstructures, and phase fractions of multi-layered zirconia with and without yttria-gradient. For this, multi-layered zirconia of 5 mol% yttria (5Y) stabilized (Katana STML) and 4Y/5Y stabilized (e.max MT Multi) were cut layerwise, sintered, and analyzed using the opalescence parameter (OP), average transmittance (AT%), translucency parameter (TP), and contrast ratio (CR). The average grain size and phase fractions were obtained from field-emission scanning electron micrographs and X-ray diffraction patterns, respectively. Although the TP values of Katana STML and e.max MT Multi did not show a significant difference (except for transition layer 1), the results of AT and CR showed that the translucency of e.max MT Multi was slightly higher than that of Katana STML (p < 0.05). The opalescence gradient was higher in Katana STML than in the e.max MT Multi. In both zirconia types, translucency increased from the dentin to enamel layer based on the AT, TP, and CR results, while OP decreased (p < 0.05). The higher translucency from the dentin to enamel layer in Katana STML was caused by the pigmentation gradient, while in e.max MT Multi, it was caused by the difference in phase fraction and the pigmentation gradient.
Collapse
Affiliation(s)
- Mi-Hyang Cho
- Department of Dental Lab, Wonkwang Health Science University, Iksan-si 54538, Republic of Korea
| | - Hyo-Joung Seol
- Department of Dental Materials, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan-si 50612, Republic of Korea
| |
Collapse
|
19
|
Alves LMM, Rodrigues CDS, Ramos NDC, Buizastrow J, Campos TMB, Bottino MA, Zhang Y, Melo RMD. Silica infiltration on translucent zirconia restorations: Effects on the antagonist wear and survivability. Dent Mater 2022; 38:2084-2095. [PMID: 36446649 PMCID: PMC9928576 DOI: 10.1016/j.dental.2022.11.015] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 09/23/2022] [Accepted: 11/11/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To assess potential antagonist wear and survival probability of silica-infiltrated zirconia compared to glass-graded, glazed, and polished zirconia. METHODS Table top restorations made of 3Y-TZP (3Y), 5Y-PSZ (5Y), and lithium disilicate (LD) were bonded onto epoxy resin preparations. Each zirconia was divided into five groups according to the surface treatment: polishing; glaze; polishing-glaze; glass infiltration; and silica infiltration. The LD restorations received a glaze layer. Specimens were subjected to sliding fatigue wear using a steatite antagonist (1.25 ×106 cycles, 200 N). The presence of cracks, fractures, and/or debonding was checked every one/third of the total number of cycles was completed. Roughness, microstructural, Scanning electron microscopy, wear and residual stress analyses were conducted. Kaplan-Meier, Mantel-Cox (log-rank) and ANOVA tests were performed for statistical analyses. RESULTS The survival probability was different among the groups. Silica infiltration and polishing-glaze led to lower volume loss than glaze and glass-infiltration. Difference was observed for roughness among the zirconia and surface treatment, while lithium disilicate presented similar roughness compared to both glazed zirconia. Scanning electron microscopy revealed the removal of the surface treatment after sliding fatigue wear in all groups. Compressive stress was detected on 3Y surfaces, while tensile stress was observed on 5Y. SIGNIFICANCE 3Y and 5Y zirconia behaved similarly regarding antagonist wear, presenting higher antagonist wear than the glass ceramic. Silica-infiltrated and polished-glazed zirconia produced lower antagonist volume loss than glazed and glass-infiltrated zirconia. Silica-infiltrated 3Y and lithium disilicate restorations were the only groups to show survival probabilities lower than 85%.
Collapse
Affiliation(s)
- Larissa Marcia Martins Alves
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil; Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 1st Ave., New York, NY 10010, United States
| | - Camila da Silva Rodrigues
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil; Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 1st Ave., New York, NY 10010, United States
| | - Nathalia de Carvalho Ramos
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Jeff Buizastrow
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 1st Ave., New York, NY 10010, United States
| | - Tiago Moreira Bastos Campos
- Department of Physics, Aeronautics Technological Institute (ITA), Praça Marechal Eduardo Gomes, 50, 12228-900 São José dos Campos, SP, Brazil
| | - Marco Antonio Bottino
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, PA 19104, United States
| | - Renata Marques de Melo
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil.
| |
Collapse
|
20
|
Alves L, Rodrigues C, Vardhaman S, Saunders C, Schneider J, Lawn B, Zhang Y. Exploring Ductility in Dental Ceramics. J Dent Res 2022; 101:1467-1473. [PMID: 35689403 PMCID: PMC9608091 DOI: 10.1177/00220345221100409] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Two damage regimes-"brittle" and "ductile"-have been identified in the literature on ceramic grinding, machining, grit blasting, and wear. In the brittle regime, the damage mechanism is essentially crack formation, while in the ductile region, it is quasiplasticity. Onset of the brittle mode poses the greater threat to strength, so it becomes important to understand the mechanics of ductile-brittle thresholds in these materials. Controlled microcontact tests with a sharp indenter are employed to establish such thresholds for a suite of contemporary computer-aided design/computer-aided manufacturing dental ceramics. Plots of flexural strength S versus indentation load P show a steep decline beyond the threshold, consistent with well-established contact mechanics relations. Threshold dimensions occur on a scale of order 1 µm and contact load of order 1 N, values pertinent to practical grit finishing protocols. The ductile side of ceramic shaping is accessed by reducing grit sizes, applied loads, and depths of cut below critical levels. It is advocated that critical conditions for ductile shaping may be most readily quantified on analogous S(P) plots, but with appropriate machining variable (grit size, depths of cut, infeed rate) replacing load P. Working in the ductile region offers the promise of compelling time and cost economies in prosthesis fabrication and preparation.
Collapse
Affiliation(s)
- L.M.M. Alves
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University, São José dos Campos, SP, Brazil
| | - C.S. Rodrigues
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University, São José dos Campos, SP, Brazil
| | - S. Vardhaman
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - C. Saunders
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA
| | - J.M. Schneider
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA
| | - B.R. Lawn
- Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA
| | - Y. Zhang
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
21
|
Park JH, Bang HJ, Choi NH, Park EJ. Translucency and masking ability of translucent zirconia; comparison with conventional zirconia and lithium disilicate. J Adv Prosthodont 2022; 14:324-333. [PMID: 36452362 PMCID: PMC9672692 DOI: 10.4047/jap.2022.14.5.324] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 10/12/2022] [Accepted: 10/17/2022] [Indexed: 01/12/2024] Open
Abstract
PURPOSE The purpose of this study is to evaluate translucency and masking ability of translucent zirconia compared to conventional zirconia and lithium disilicate materials. MATERIALS AND METHODS Three types of zirconia blocks with different yttria contents (3Y, 4Y, 5.5Y) and LS blocks (Rosetta SM) were used. Ten specimens for each group were fabricated with 10 mm diameter, with both 0.8 mm and 1.5 mm thicknesses (± 0.02 mm). All groups of zirconia specimens were sintered and polished according to the manufacturer's instructions. To calculate the translucency parameter (TP), CIELAB value was measured with a spectrophotometer on black and white backgrounds. To investigate the color masking abilities, background shades of A2, normal dentin, discolored dentin, and titanium were used. The color difference (ΔE) was calculated with the CIELAB values of A2 shade background as a reference compared with the values in the various backgrounds. One-way ANOVA and Bonferroni tests were conducted (P < .05). RESULTS The TP values of zirconia specimens increased as the yttria content increased. All materials used in the study were able to adequately mask normal dentin shade (ΔE < 5.5), but were incapable of masking severely discolored dentin (ΔE > 5.5). On the titanium background, all materials of 1.5 mm thickness were able to mask the background shade, but with a thickness of 0.8 mm, only 3Y-TZP and 4Y-PSZ were able to mask titanium background. CONCLUSION All zirconia materials and lithium disilicate specimens used in this study were unable to adequately mask the shade of severely discolored dentin. It is recommended to use 3Y-TZP or 4Y-PSZ with a sufficient thickness of 0.8 mm or more to mask titanium.
Collapse
Affiliation(s)
- Joon Hee Park
- Department of Prosthodontics, School of Medicine, Ewha Womans University, Seoul, Republic of Korea
| | | | - Nak-Hyun Choi
- Yonsei Design Dental Clinic, Seoul, Republic of Korea
| | - Eun-Jin Park
- Department of Prosthodontics, School of Medicine, Ewha Womans University, Seoul, Republic of Korea
| |
Collapse
|
22
|
Malallah AD, Hasan NH. Thickness and yttria percentage influences the fracture resistance of laminate veneer zirconia restorations. Clin Exp Dent Res 2022; 8:1413-1420. [PMID: 36099336 PMCID: PMC9760162 DOI: 10.1002/cre2.658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 08/14/2022] [Accepted: 08/18/2022] [Indexed: 01/26/2023] Open
Abstract
OBJECTIVES Mechanical properties are cardinal for the long-term clinical success of laminate veneer restorations but the selection of new restorative materials should ideally be based on clinical evidence, therefore, in vitro testing of dental materials is a good alternative to evaluate their properties and understand their behavior so this study aimed to compare and evaluate the effect of two different thicknesses and yttria percentage on the fracture resistance of laminate veneer zirconia restorations. MATERIALS AND METHODS Forty laminate veneer restoration prepared from partial sintering zirconia of 3Y (yttria), 5Y (yttria), combined 3Y&5Y (yttria), and lithium disilicate. Specimens were assigned into four main groups according to their percentage of yttria content (n = 10) and subgrouped into two thicknesses (0.5 mm thickness and 0.3 mm thickness) (n = 5) as follows: Group I, II, III, and IV (Group I for lithium disilicate (control), Group II for 3Y zirconia, Group III for 5Y zirconia, and Group IV for combined 3Y&5Y zirconia), each of them subdivided according to their thickness into two subgroups (n = 5 for each one) and resistance to fracture for each restoration was evaluated using a universal testing machine. Data were analyzed using a one-way analysis of variance and Duncan's tests at a 5% level of significance. RESULTS The thickness of laminate veneer restoration significantly affects the fracture resistance value of all type of laminate veneers restorations (fracture resistance mean value was highest for 0.5 mm thickness and lower for 0.3 mm thickness restorations) and yttria percentage significantly affect fracture resistance value of zirconia laminate veneer restorations (fracture resistance mean value was highest for 0.5 mm thickness of 3Y zirconia [865 N] and combined 3Y&5Y zirconia [846 N]). CONCLUSIONS Reducing the thickness of laminate zirconia veneer restorations to 0.3 mm reduces its fracture resistance and increasing yttria percentage had an adverse effect on fracture resistance of zirconia laminate veneer restorations.
Collapse
Affiliation(s)
- Ali Dhahee Malallah
- Department of Conservative Dentistry, College of DentistryUniversity of MosulMosulIraq
| | - Nadia H. Hasan
- Department of Conservative Dentistry, College of DentistryUniversity of MosulMosulIraq
| |
Collapse
|
23
|
Lim CH, Vardhaman S, Reddy N, Zhang Y. Composition, processing, and properties of biphasic zirconia bioceramics: relationship to competing strength and optical properties. CERAMICS INTERNATIONAL 2022; 48:17095-17103. [PMID: 37701057 PMCID: PMC10497227 DOI: 10.1016/j.ceramint.2022.02.265] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
Abstract
A study is made of relationships between composition, processing, structure and properties of biphasic zirconia bioceramics. The focus is on zirconia compositions with different yttria dopant contents used in modern dental restorations, namely 3 - 5 mol% yttria stabilized zirconia (3YSZ, 4YSZ, and 5YSZ). Crystallographies and densities are surveyed, sintering conditions examined, and microstructures characterized. Strength and optical tests are conducted on each YSZ, and dependencies on sintering temperature, cubic content and grain size analyzed. Strength correlates with the amount of tetragonal zirconia (t-ZrO2) crystals with large lattice distortions (tetragonality). YSZ translucency correlates with content of cubic zirconia (c-ZrO2) and t-ZrO2 with low levels of tetragonality. Consistent with literature reporting, the materials rank in decreasing order 3YSZ, 4YSZ to 5YSZ for strength but increasing order for translucency. However, for a given composition, the data suggest that the strengths of densely sintered 3YSZ and 4YSZ actually increase with translucency, although that of 5YSZ remains undiminished. These trends are in apparent contradiction to prevailing experience, and offer potential future processing routes to optimization of clinical materials.
Collapse
Affiliation(s)
- Chek Hai Lim
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, PA 19104, USA
| | - Sonaj Vardhaman
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, PA 19104, USA
| | - Niyati Reddy
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, PA 19104, USA
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, PA 19104, USA
| |
Collapse
|
24
|
Badr Z, Culp L, Duqum I, Lim CH, Zhang Y, A. Sulaiman T. Survivability and fracture resistance of monolithic and multi‐yttria‐layered zirconia crowns as a function of yttria content: A mastication simulation study. J ESTHET RESTOR DENT 2022; 34:633-640. [DOI: 10.1111/jerd.12907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 02/28/2022] [Accepted: 03/13/2022] [Indexed: 11/30/2022]
Affiliation(s)
- Zaid Badr
- Department of Adult Restorative Dentistry University of Nebraska Medical Center, College of Dentistry Lincoln Nebraska USA
| | - Lee Culp
- Sculpture Studios Cary North Carolina USA
| | - Ibrahim Duqum
- Division of Comprehensive Oral Health University of North Carolina at Chapel Hill Adams School of Dentistry Chapel Hill North Carolina USA
| | - Chek Hai Lim
- Department of Preventive and Restorative Sciences, School of Dental Medicine University of Pennsylvania Philadelphia Pennsylvania USA
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine University of Pennsylvania Philadelphia Pennsylvania USA
| | - Taiseer A. Sulaiman
- Division of Comprehensive Oral Health University of North Carolina at Chapel Hill Adams School of Dentistry Chapel Hill North Carolina USA
| |
Collapse
|
25
|
Wear Behavior of Different Generations of Zirconia: Present Literature. Int J Dent 2022; 2022:9341616. [PMID: 35295406 PMCID: PMC8920625 DOI: 10.1155/2022/9341616] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 01/16/2022] [Accepted: 02/10/2022] [Indexed: 12/22/2022] Open
Abstract
Objective. The wear behavior of the novel zirconia generation is less well understood and may be affected by compositional modifications compared to the conventional zirconia. Materials and Methods. Combinations of keywords such as “zirconia,” “high translucent,” and “wear” were searched in PubMed and Google Scholar databases up to May 2021. The total of 23 relevant articles was selected according to inclusion criteria. Results. Reports show comparable wear resistance of translucent zirconia to the conventional zirconia despite an increased cubic phase content and lower mean flexural strength. A meticulously polished surface creates the lowest surface roughness, producing favorable zirconia wear resistance and antagonist wear compared to a glazed surface. In comparison to other ceramic materials, zirconia produces the least wear on an enamel antagonist and almost undetectable wear when opposed by zirconia. Wear when paired against resin materials yields a favorable outcome, whereas wear behavior against a metal antagonist varies with the surface hardness of the metal. Conclusions. All zirconia generations are considered wear-friendly to all types of antagonists. Nonetheless, comparative studies on antagonist wear opposing zirconia of different compositions are still limited and further investigation is required.
Collapse
|
26
|
Evaluation of Er,Cr:YSGG laser irradiation for debonding of zirconia hybrid abutment crowns from titanium bases. Lasers Med Sci 2022; 37:2675-2685. [DOI: 10.1007/s10103-022-03539-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 02/28/2022] [Indexed: 10/18/2022]
|
27
|
Arcila LVC, Ramos NDC, Campos TMB, Dapieve KS, Valandro LF, de Melo RM, Bottino MA. Mechanical behavior and microstructural characterization of different zirconia polycrystals in different thicknesses. J Adv Prosthodont 2022; 13:385-395. [PMID: 35003554 PMCID: PMC8712112 DOI: 10.4047/jap.2021.13.6.385] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 12/02/2021] [Accepted: 12/10/2021] [Indexed: 11/23/2022] Open
Abstract
PURPOSE To characterize the microstructure of three yttria partially stabilized zirconia ceramics and to compare their hardness, indentation fracture resistance (IFR), biaxial flexural strength (BFS), and fatigue flexural strength. MATERIALS AND METHODS Disc-shaped specimens were obtained from 3Y-TZP (Vita YZ HT), 4Y-PSZ (Vita YZ ST) and 5Y-PSZ (Vita YZ XT), following the ISO 6872/2015 guidelines for BFS testing (final dimensions of 12 mm in diameter, 0.7 and 1.2 ± 0.1 mm in thicknesses). Energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses were performed, and mechanical properties were assessed by Vickers hardness, IFR, quasi-static BFS and fatigue tests. RESULTS All ceramics showed similar chemical compositions, but mainly differed in the amount of yttria, which was higher as the amount of cubic phase in the diffractogram (5Y-PSZ > 4Y-PSZ > 3Y-TZP). The 4Y- and 5Y-PSZ specimens showed surface defects under SEM, while 3Y-TZP exhibited greater grain uniformity on the surface. 5Y-PSZ and 3Y-TZP presented the highest hardness values, while 3Y-TZP was higher than 4Y- and 5Y-PSZ with regard to the IFR. The 5Y-PSZ specimen (0.7 and 1.2 mm) showed the worst mechanical performance (fatigue BFS and cycles until failure), while 3Y-TZP and 4Y-PSZ presented statistically similar values, higher than 5Y-PSZ for both thicknesses (0.7 and 1.2 mm). Moreover, 3Y-TZP showed the highest (1.2 mm group) and the lowest (0.7 mm group) degradation percentage, and 5Y-PSZ had higher strength degradation than 4Y-PSZ group. CONCLUSION Despite the microstructural differences, 4Y-PSZ and 3Y-TZP had similar fatigue behavior regardless of thickness. 5Y-PSZ had the lowest mechanical performance.
Collapse
Affiliation(s)
- Laura Viviana Calvache Arcila
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, São José Dos Campos, Brazil
| | - Nathália de Carvalho Ramos
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, São José Dos Campos, Brazil.,College of Dentistry, University of Taubaté (Unitau), Taubaté, Brazil
| | | | | | - Luiz Felipe Valandro
- College of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Renata Marques de Melo
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, São José Dos Campos, Brazil
| | - Marco Antonio Bottino
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, São José Dos Campos, Brazil
| |
Collapse
|
28
|
Pinge S, Shetty R, Shetty S, Banga P, Zahid M. Zirconia monolithic veneers: A durable and cosmetic alternative to regular veneers? ADVANCES IN HUMAN BIOLOGY 2022. [DOI: 10.4103/aihb.aihb_5_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
|
29
|
Effect of finishing/polishing techniques and aging on topography, C. albicans adherence, and flexural strength of ultra-translucent zirconia: an in situ study. Clin Oral Investig 2022; 26:889-900. [PMID: 34448074 PMCID: PMC9902030 DOI: 10.1007/s00784-021-04068-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 07/01/2021] [Indexed: 02/08/2023]
Abstract
OBJECTIVE To investigate the influence of different finishing/polishing techniques and in situ aging on the flexural strength (σ), surface roughness, and Candida albicans adherence of 5 mol% yttria-stabilized zirconia (ultratranslucent zirconia). MATERIALS AND METHODS A total of 120 zirconia bars (Prettau Anterior, Zirkonzahn) with dimensions of 8 × 2 × 0.5 mm were divided into 8 groups (n = 15) according to two factors: "in situ aging" (non-aged and aged (A)) and "finishing/polishing" (control (C), diamond rubber polishing (R), coarse grit diamond bur abrasion (B), and coarse grit diamond bur abrasion + diamond rubber polishing (BR)). Half of the samples from each group were subjected to a 60-day in situ aging by fixing the bars into cavities prepared in the posterior region of the base of complete or partial dentures of 15 patients. The samples were then subjected to the mini flexural (σ) test (1 mm/min). A total of 40 zirconia blocks (5 × 5 × 2 mm) were prepared and subjected to roughness (Ra) analyses and fungal adherence and complementary analyses (X-ray diffraction (XRD) and scanning electron microscopy (SEM)). The data of mean σ (MPa) and roughness Ra (μm) were statistically analyzed by two-way and one-way ANOVA, respectively, and Tukey's test. The Weibull analysis was performed for σ data. The fungal adhesion (Log CFU/mL) data were analyzed by Kruskal-Wallis tests. RESULTS For flexural resistance, the "finishing/polishing" factor was statistically significant (P = 0.0001); however, the "in situ aging" factor (P = 0.4458) was not significant. The non-aged (507.3 ± 115.7 MPa) and aged (487.6 ± 118.4 MPa) rubber polishing groups exhibited higher mean σ than the other techniques. The non-aged (260.2 ± 43.3 MPa) and aged (270.1 ± 48.8 MPa) bur abrasion groups presented lower σ. The coarse-grit diamond bur abrasion group (1.82 ± 0.61 µm) presented the highest roughness value (P = 0.001). Cell adhesion was not different among groups (P = 0.053). Group B presented the most irregular surface and the highest roughness Ra of 0.61 m. CONCLUSIONS The finishing of ultratranslucent zirconia might be preferably done with a diamond rubber polisher. Moreover, the protocols used did not interfere with Candida albicans adhesion. CLINICAL RELEVANCE Coarse-grit diamond burs might be avoided for finishing ultratranslucent monolithic zirconia, which might be preferably performed with a diamond rubber polisher.
Collapse
|
30
|
Ashy LM, Al-Mutairi A, Al-Otaibi T, Al-Turki L. The effect of thermocyclic aging on color stability of high translucency monolithic lithium disilicate and zirconia ceramics luted with different resin cements: an in vitro study. BMC Oral Health 2021; 21:587. [PMID: 34798878 PMCID: PMC8603505 DOI: 10.1186/s12903-021-01963-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 11/05/2021] [Indexed: 11/10/2022] Open
Abstract
Background High-translucency monolithic zirconia were developed to combine the esthetics of all ceramic restorations with the strength properties of zirconia. The purpose of this study was to compare the color stability of high-translucency monolithic zirconia ceramics with lithium disilicate luted using light-cure versus dual-cure resin cements following thermocyclic aging. Methods Forty specimens, each composed of 10 × 10 × 1 mm ceramic slice luted to dentin surface of an extracted tooth, were prepared and assigned into four groups (n = 10) as follows; LiDi/LC: lithium disilicate luted by light-cure resin cement; LiDi/DC: lithium disilicate luted by dual-cure resin cement; Zr/LC: zirconia luted by light-cure resin cement; and Zr/DC: zirconia luted by dual-cure resin cement. Color analysis of the specimens was performed before and after 3000 thermal cycles by means of spectrophotometry. The CIE L*a*b* values of the specimens were measured, and data were analyzed statistically at a significance value of p < 0.05. Results Thermocycling resulted in a significant change in color coordinates of specimens with an overall ΔE = 3.59 ± 1.60, but there was no statistically significant difference in the color change value among all tested groups (P = 0.756). Conclusions At 1 mm restoration thickness, the color stability of high-translucency monolithic lithium disilicate and zirconia ceramics were not significantly different irrespective of the cement type used. Clinical implication Understanding the difference in color stability of dental ceramics may help in determining long-term esthetic result.
Collapse
Affiliation(s)
- Linah M Ashy
- Department of Oral and Maxillofacial Prosthodontics (OMP), King Abdulaziz University Faculty of Dentistry (KAUFD), P.O. Box 80209, Jeddah, 21589, Saudi Arabia.
| | | | | | - Lulwa Al-Turki
- Department of Oral and Maxillofacial Prosthodontics (OMP), King Abdulaziz University Faculty of Dentistry (KAUFD), P.O. Box 80209, Jeddah, 21589, Saudi Arabia
| |
Collapse
|
31
|
Alao AR, Mohd Azhari MA. Investigation of indentation size effect and R-curve behaviour of Li 2O-SiO 2 and Li 2O-2SiO 2 glass ceramics. J Mech Behav Biomed Mater 2021; 124:104842. [PMID: 34555624 DOI: 10.1016/j.jmbbm.2021.104842] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 09/14/2021] [Accepted: 09/15/2021] [Indexed: 11/26/2022]
Abstract
Indentation size effect (ISE) and R-curve behaviour of Li2O-SiO2 and Li2O-2SiO2 glass ceramics are investigated using micro-indentation and indentation-strength (IS) techniques, respectively. Vickers micro-indentations were applied on both materials at the load of 0.10-19.6 N to determine the load influence on the measured hardness. For the IS-measured fracture toughness, the load ranged from 1.96 to 19.6 N. The hardness decreased with increasing load by 20% and 18% on Li2O-SiO2 and Li2O-2SiO2 glass ceramics, respectively, indicating the ISE behaviour on both materials. The fracture toughness increased with the load by 27% and 59% on Li2O-SiO2 and Li2O-2SiO2 glass ceramics, respectively, signifying the R-curve behaviour. The ISE behaviour of both materials was analysed using the Meyer's, Hays-Kendall (HK), proportional specimen resistance (PSR), Nix-Gao (NG), modified PSR (MPSR) and elastic plastic deformation (EPD) models while the R-curve behaviour was analysed by the fractional power law. The Meyer's index of both materials was less than 2, strongly confirming the ISE existence. The HK, PSR and NG models were only suitable to determine intrinsic Vickers hardness for Li2O-2SiO2 glass ceramic while the MPSR and EPD models were successful for both materials. The fractional power law gave higher R-curve steepness for Li2O-2SiO2 than Li2O-SiO2 glass ceramics. Also, material and brittleness indices predicted, respectively, higher quasi-plasticity and better machinability for Li2O-2SiO2 than Li2O-SiO2 glass ceramics indicating superior performance in the former to the latter. Finally, this study presents a new significant insight into the micro-mechanisms of fracture tolerance behaviour of these glass ceramics which is critical to their functional performance as structural ceramics.
Collapse
Affiliation(s)
- Abdur-Rasheed Alao
- Mechanical Engineering Programme Area, Faculty of Engineering, Universiti Teknologi, Brunei, Gadong, BE1410, Brunei Darussalam.
| | - Mohd Azmir Mohd Azhari
- Faculty of Manufacturing Engineering, Universiti Malaysia Pahang, 26600, Pekan, Pahang, Malaysia
| |
Collapse
|
32
|
Comparison of Fracture Load of the Four Translucent Zirconia Crowns. Molecules 2021; 26:molecules26175308. [PMID: 34500741 PMCID: PMC8433771 DOI: 10.3390/molecules26175308] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 08/03/2021] [Accepted: 08/17/2021] [Indexed: 02/07/2023] Open
Abstract
Recently, translucent zirconia has become the most prevalent material used as a restorative material. This study aimed to compare the crown fracture load of the four most common different translucent zirconia brands available in the market at 1.5 mm thickness. Standardized tooth preparations for a full ceramic crown were designed digitally with software (AutoCAD) by placing a 1.0 mm chamfer margin and 1.5 mm occluso-cervical curvature for the crown sample manufacturing. Stylized crowns were chosen to control the thickness of the crown. The axial and occlusal thickness were standardized to 1.5 mm thickness except at the central pit, which was 1.3 mm thick. The STL file for the tooth dies was prepared using software (3Shape TRIOS® Patient Monitoring, Copenhagen, Denmark). The tooth dies were printed with a resin material (NextDent Model 2.0, Vertex-Dental B.V., Soesterberg, The Netherlands) using a 3D printing software (3D Sprint® Client Version 3.0.0.2494) from a 3D printer (NextDent™ 5100, Vertex-Dental B.V., Soesterberg, The Netherlands). The printing layer thickness was 50 µm. Then, a total of twenty-eight (N = 28) stylized crowns were milled out of AmannGirrbach (Amann Girrbach GmbH, Pforzheim, Germany) (n = 7), Cercon HT (Dentsply Sirona, Bensheim, Germany) (n = 7), Cercon XT (Dentsply Sirona, Bensheim, Germany) (n = 7), and Vita YZ XT (Zahnfabrik, Bäd Sackingen, Germany) (n = 7). Following sintering the crowns, sandblasting was performed and they were bonded to the tooth dies with the resin cement (RelyX U-200, 3M ESPE, Seefeld, Germany) and permitted to self-cure under finger pressure for 6 min. The crowns were loaded on the occlusal surface in a universal testing machine (MTS Centurion) with a stainless-steel ball indenter (7 mm radius) with a loading rate of 1 mm/min to contact the stylized crowns on each of the four cusps until failure. A rubber sheet (1.5 mm thickness) was positioned between the crown and indenter, which helped with the load distribution. Statistical analysis was done using SPSS version 20 (IBM Company, Chicago, USA). The fracture loads were analyzed using Dunnett’s T3 test, and the number of cracks was analyzed using the Mann–Whitney U test among the groups. The significant level was set at p value = 0.05. The mean fracture loads were 3086.54 ± 441.74 N, 4804.94 ± 70.12 N, 3317.76 ± 199.80 N, and 2921.87 ± 349.67 N for AmannGirrbac, Cercon HT, Cercon XT, and Vita YZ XT, respectively. The mean fracture loads for the surfaces with the greatest number of cracks (excluding the occlusal surfaces) were on the lingual surface for AmannGirrbach and Cercon HT, on the distal and mesial for Cercon XT, and on the buccal for Vita YZ XT. We found that the AmannGirrbach had the most overall cracks. Cercon XT had the greatest number of occlusal cracks and appeared to be the most shattered. Cercon HT had the least number of cracks. In conclusion, Cercon HT presented the best strength properties, the highest fracture load, and no visible cracks. AmannGirrbach presented the lowest strength properties.
Collapse
|
33
|
Microstructural development during crystallization firing of a dental-grade nanostructured lithia-zirconia glass-ceramic. Ann Ital Chir 2021. [DOI: 10.1016/j.jeurceramsoc.2021.04.036] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
34
|
Øilo M, Haugli K, Rønold HJ, Ulsund AH, Ruud A, Kvam K. Pre-cementation procedures' effect on dental zirconias with different yttria content. Dent Mater 2021; 37:1425-1436. [PMID: 34330519 DOI: 10.1016/j.dental.2021.07.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 04/26/2021] [Accepted: 07/07/2021] [Indexed: 11/30/2022]
Abstract
OBJECTVE Several pre-cementation procedures have been advocated to enhance adhesion between zirconia and resin-based cement. There is, however, limited documentation on how these pre-treatments affect the strength of zirconia crowns as most tests are performed on discs or bars. The aim was to assess the effect of pre-cementation procedures on fracture mode, fracture strength and cement retention on zirconia. METHODS Two dental zirconia materials with different yttria content were assessed (<4 and>5 mol%). Both discs (n = 45) and crown-shaped specimens (n = 30) of the two materials were pretreated with either air-abrasion or hot-etching with KHF2 and compared with untreated controls with regards to surface roughness, crystallography, wettability, cement adhesion and fracture strength. RESULTS AND SIGNIFICANCE Air-abrasion improves adhesion and strength of zirconia with moderate yttria content (<4 mol%). Acid etching with heated KHF2 showed the best effect on strength and cement retention on zirconia with higher yttria content (>5 mol%). Application of KHF2 was, however, complicated on crown-shaped specimens. Pre-treatment and cementation protocols should be optimized for different dental zirconias to improve both strength and retention.
Collapse
Affiliation(s)
- Marit Øilo
- NIOM, Nordic Institute of Dental Materials, Oslo, Norway; Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Bergen, Norway.
| | - Ketil Haugli
- NIOM, Nordic Institute of Dental Materials, Oslo, Norway; OSLOMET, Oslo Metropolitan University, Oslo, Norway
| | - Hans Jacob Rønold
- NIOM, Nordic Institute of Dental Materials, Oslo, Norway; Department of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Oslo, Norway
| | - Amanda H Ulsund
- Department of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Oslo, Norway
| | - Amund Ruud
- NIOM, Nordic Institute of Dental Materials, Oslo, Norway
| | - Ketil Kvam
- NIOM, Nordic Institute of Dental Materials, Oslo, Norway
| |
Collapse
|
35
|
Too TDC, Inokoshi M, Nozaki K, Shimizubata M, Nakai H, Liu H, Minakuchi S. Influence of sintering conditions on translucency, biaxial flexural strength, microstructure, and low-temperature degradation of highly translucent dental zirconia. Dent Mater J 2021; 40:1320-1328. [PMID: 34193728 DOI: 10.4012/dmj.2020-448] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
There is limited research on the influence of different sintering temperatures on the properties of highly translucent zirconia ceramics. This study demonstrated the influence of different sintering temperatures on the translucency, crystallographic structure, biaxial flexural strength, microstructure, and low-temperature degradation (LTD) of three highly translucent zirconia grades, i.e., 3 mol% yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP), 4 mol% yttria-partially-stabilized zirconia (4Y-PSZ), and 5 mol% yttria-PSZ (5Y-PSZ). The specimens were characterized using colorimetry, X-ray diffraction, scanning electron microscopy, Weibull analysis, and LTD tests (134°C; 20 h). The increase in the sintering temperature did not affect the translucency of 3Y-TZP, whereas it increased the translucencies of 4Y-PSZ and 5Y-PSZ. All the zirconia grades exhibited grain enlargement and unchanged biaxial flexural strengths with the increase in the sintering temperature. The degradation of 3Y-TZP and 4Y-PSZ at a sintering temperature of 1,600°C was faster than that at other sintering temperatures.
Collapse
Affiliation(s)
- Thaw Di Cho Too
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Masanao Inokoshi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Kosuke Nozaki
- Department of Fixed Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Makoto Shimizubata
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Hiroto Nakai
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Hengyi Liu
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Shunsuke Minakuchi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| |
Collapse
|
36
|
Solá-Ruíz MF, Rico-Coderch A, Montiel-Company JM, Fons-Badal C, Verdejo-Solá B, Agustín-Panadero R. Influence of the chemical composition of monolithic zirconia on its optical and mechanical properties. Systematic review and meta-regression. J Prosthodont Res 2021; 66:193-207. [PMID: 34176849 DOI: 10.2186/jpr.jpr_d_20_00218] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This systematic review set out to investigate the influence of chemical composition and specimen thickness of monolithic zirconia on its optical and mechanical properties. Meta-analysis and meta-regression analyzed the effects of variations in percentages of yttrium, aluminum, and specimen thickness of monolithic zirconia. STUDY SELECTION The review followed recommendations put forward in the PRISMA checklist. An electronic search for relevant articles published up to October 2019 was conducted in the Pubmed, Cochrane, Scopus, Scielo, and Web of Science databases, with no language limits and articles published in the last 10 years. From 167 relevant articles; applying inclusion criteria based on the review's PICO question, 26 articles were selected for qualitative synthesis (systematic review) and 24 for quantitative synthesis (meta-analysis). Experimental in vitro studies published were selected and their quality was assessed using the modified Consort scale for in vitro studies of dental materials. RESULTS The variables yttrium, aluminum and thickness were analyzed in random effects models, observing high heterogeneity ( > 75%), and finding statistically significant influences on the properties of monolithic zirconia (p<0.05). CONCLUSIONS Within the review's limitations, it may be concluded that variations in the percentage of yttrium and aluminum influence the optical and mechanical properties of monolithic zirconia, making it more or less esthetic and resistant in relation to each variable. The clinical implications of these findings can help select the most appropriate type of zirconia to meet the different clinical needs when restoring different regions (posterior or anterior).
Collapse
Affiliation(s)
| | - Aitana Rico-Coderch
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia
| | | | - Carla Fons-Badal
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia
| | - Blanca Verdejo-Solá
- Department of Medicine, Faculty of Medicine and Dentistry, Universidad Cardenal Herrera-CEU, Valencia
| | - Rubén Agustín-Panadero
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia
| |
Collapse
|
37
|
Luz JN, Kaizer MDR, Ramos NDC, Anami LC, Thompson VP, Saavedra GDSFA, Zhang Y. Novel speed sintered zirconia by microwave technology. Dent Mater 2021; 37:875-881. [PMID: 33715863 PMCID: PMC11283878 DOI: 10.1016/j.dental.2021.02.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 02/18/2021] [Accepted: 02/24/2021] [Indexed: 01/21/2023]
Abstract
OBJECTIVE Continuous efforts have been made to hasten the zirconia densification process without compromising properties. This study evaluated the long-term structural durability of microwave speed-sintered zirconia (MWZ) relative to a conventionally sintered zirconia (CZ). METHODS As-machined dental 3Y-TZP discs (Ø12 × 1.2 mm) were speed sintered at 1450 °C for 15 min using an industrial microwave oven, while conventional sintering was conducted in a standard dental furnace at 1530 °C for 2 h. Both were followed by natural cooling. The total sintering time was 105 min for MWZ and 600 min for CZ. Groups were compared regarding density, grain size, phase composition, and fracture resistance. Structural durability was investigated employing two fatigue protocols, step-stress and dynamic fatigue. RESULTS Compared to CZ, MWZ exhibited a slightly lower density (MWZ = 5.98 g/cm3, CZ = 6.03 g/cm3), but significantly smaller grain sizes (MWZ = 0.53 ± 0.09 μm, CZ = 0.89 ± 0.10 μm), lower cubic-zirconia contents (MWZ = 15.3%, CZ = 22.7%), and poorer translucency properties (TP) (MWZ = 13 ± 1, CZ = 29 ± 0.8). However, the two materials showed similar flexural strength (MWZ = 978 ± 112 MPa, CZ = 1044 ± 161 MPa). Additionally, step-stress testing failed to capture the fatigue effect in 3Y-TZP, whereas dynamic fatigue revealed structural degradation due to moisture-assisted slow-crack-growth (SCG). Finally, MWZ possessed a slightly higher Weibull modulus (MWZ = 7.9, CZ = 6.7) but similar resistance to SCG (MWZ = 27.5, CZ = 24.1) relative to CZ. SIGNIFICANCE Dental 3Y-TZP with similar structural durability can be fabricated six-times faster by microwave than conventional sintering.
Collapse
Affiliation(s)
- Julio Nogueira Luz
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of Sao Jose dos Campos, Sao Paulo State University (UNESP), 777 Eng. Francisco Jose Longo Avenue, Sao Jose dos Campos, SP 12245-000, Brazil
| | | | - Nathália de Carvalho Ramos
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of Sao Jose dos Campos, Sao Paulo State University (UNESP), 777 Eng. Francisco Jose Longo Avenue, Sao Jose dos Campos, SP 12245-000, Brazil
| | - Lilian Costa Anami
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of Sao Jose dos Campos, Sao Paulo State University (UNESP), 777 Eng. Francisco Jose Longo Avenue, Sao Jose dos Campos, SP 12245-000, Brazil
| | - Van P Thompson
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 1st Ave., New York, NY 10010, United States
| | - Guilherme de Siqueira Ferreira Anzaloni Saavedra
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology of Sao Jose dos Campos, Sao Paulo State University (UNESP), 777 Eng. Francisco Jose Longo Avenue, Sao Jose dos Campos, SP 12245-000, Brazil.
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, University of Pennsylvanian, School of Dental Medicine, 240 S. 40th St., Philadelphia, PA 19104, United States.
| |
Collapse
|
38
|
Machry RV, Cadore-Rodrigues AC, Borges ALS, Pereira GK, Kleverlaan CJ, Venturini AB, Valandro LF. Fatigue resistance of simplified CAD–CAM restorations: Foundation material and ceramic thickness effects on the fatigue behavior of partially- and fully-stabilized zirconia. Dent Mater 2021; 37:568-577. [DOI: 10.1016/j.dental.2021.01.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 10/15/2020] [Accepted: 01/09/2021] [Indexed: 10/22/2022]
|
39
|
Ramos GF, Ramos NC, Alves LMM, Kaizer MR, Borges ALS, Campos TMB, Melo RM. Failure probability and stress distribution of milled porcelain-zirconia crowns with bioinspired/traditional design and graded interface. J Mech Behav Biomed Mater 2021; 119:104438. [PMID: 33798936 DOI: 10.1016/j.jmbbm.2021.104438] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 09/14/2020] [Accepted: 02/26/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVE To evaluate the failure probability and stress distribution of traditional and bioinspired porcelain-zirconia milled crowns, with and without silica infiltration (graded zirconia). METHODS Traditional crown design had a zirconia infrastructure veneered with porcelain; Bioinspired, had a porcelain infrastructure with translucent-zirconia veneer; Graded and Graded Bioinspired crowns had their zirconia layer infiltrated by silica (n = 25). The cameo surface of each crown (porcelain or zirconia) was glazed. The restoration layers were fused by a vitreous connector and the crowns were adhesively cemented to dies. The specimens were then mechanically cycled in a sliding machine using 100 N load at 4 Hz. The specimens were tested until 2 × 106 cycles, and every 0.5 × 106 cycles the crowns were evaluated under stereomicroscopy for the presence of failures. The stress distribution was inspected with Finite Element Analyses. RESULTS The predominant failure modes for the Traditional and Graded crowns were delamination and cracking, respectively. The Weibull parameters beta and eta were, respectively: Traditional 1.30 and 2.3 × 106 cycles, and Graded 1.95 and 2.3 × 106 cycles. Thus, the Traditional and Graded crowns presented greater susceptibility to failure due to fatigue, while the Bioinspired and Graded Bioinspired crowns showed no fatigue effect using 100N load, showing beta = 1 and eta of approximately 17 × 106 cycles. Also, through finite element analyses, it was verified that the Bioinspired and Graded Bioinspired crowns presented the best stress distribution on both crowns and dental structures. SIGNIFICANCE Bioinspired and Graded Bioinspired crowns had the lowest failure probability and better stress distribution and may be considered robust long lasting restorations.
Collapse
Affiliation(s)
- G F Ramos
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| | - N C Ramos
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil; College of Dentistry, Sao Francisco University (USF), 218 Sao Francisco de Assis Avenue, 12916-900, Bragança Paulista, SP, Brazil.
| | - L M M Alves
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| | - M R Kaizer
- College of Dentistry, Positivo University (UP), 5300 Prof. Pedro Viriato Parigot de Souza Street, 81280-330, Curitiba, PR, Brazil.
| | - A L S Borges
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| | - T M B Campos
- Physics Department, Technological Institute of Aeronatics (ITA), 50 Praça Marechal Eduardo Gomes, 12228-900, São José Dos Campos, SP, Brazil.
| | - R M Melo
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| |
Collapse
|
40
|
Influence of the foundation substrate on the fatigue behavior of bonded glass, zirconia polycrystals, and polymer infiltrated ceramic simplified CAD-CAM restorations. J Mech Behav Biomed Mater 2021; 117:104391. [PMID: 33618242 DOI: 10.1016/j.jmbbm.2021.104391] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 02/03/2021] [Accepted: 02/07/2021] [Indexed: 01/09/2023]
Abstract
This study evaluated the influence of distinct substrates on the mechanical fatigue behavior of adhesively cemented simplified restorations made of glass, polycrystalline or polymer infiltrated-ceramics. CAD/CAM ceramic blocks (feldspathic - FEL; lithium disilicate - LD; yttria-stabilized zirconia - YZ; and polymer-infiltrated ceramic network - PICN) were shaped into discs (n = 15, Ø = 10 mm; thickness = 1.0 mm), mimicking a simplified monolithic restoration. After, they were adhesively cemented onto different foundation substrates (epoxy resin - ER; or Ni-Cr metal alloy - MA) of the same shape (Ø = 10 mm; thickness = 2.0 mm). The assemblies were subjected to fatigue testing using a step-stress approach (200N-2800 N; step-size of 200 N; 10,000 cycles per step; 20 Hz) upon the occurrence of a radial crack or fracture. The data was submitted to two-way ANOVA (α = 0.05) to analyze differences considering 'ceramic material' and 'type of substrate' as factors. In addition, a survival analysis (Kaplan Meier with Mantel-Cox log-rank post-hoc tests; α = 0.05) was conducted to obtain the survival probability during the steps in the fatigue test. Fractographic and finite element (FEA) analyzes were also conducted. The factors 'ceramic material', 'type of substrate' and the interaction between both were verified to be statistically significant (p < .001). All evaluated ceramics presented higher fatigue failure load (FFL), cycles for failure (CFF) and survival probabilities when cemented to the metallic alloy substrate. Among the restorative materials, YZ and LD restorations presented the best fatigue behavior when adhesively cemented onto the metallic alloy substrate, while FEL obtained the lowest FFL and CFF for both substrates. The LD, PICN and YZ restorations showed similar fatigue performance considering the epoxy resin substrate. A more rigid foundation substrate improves the fatigue performance of adhesively cemented glass, polycrystalline and polymer infiltrated-ceramic simplified restorations.
Collapse
|
41
|
Pitta J, Hjerppe J, Burkhardt F, Fehmer V, Mojon P, Sailer I. Mechanical stability and technical outcomes of monolithic CAD/CAM fabricated abutment-crowns supported by titanium bases: An in vitro study. Clin Oral Implants Res 2020; 32:222-232. [PMID: 33258267 DOI: 10.1111/clr.13693] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2020] [Revised: 11/08/2020] [Accepted: 11/21/2020] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To evaluate mechanical stability (survival and complication rates) and bending moments of different all-ceramic monolithic restorations bonded to titanium bases (hybrid abutment-crowns) or to customized titanium abutments compared to porcelain-fused-to-metal crowns (PFM) after thermo-mechanical aging. MATERIAL AND METHODS Sixty conical connection implants (4.3 mm-diameter) were divided in five groups (n = 12): PFM using gold abutment (GAbut-PFM), lithium disilicate crown bonded to customized titanium abutment (TAbut+LDS), lithium disilicate abutment-crown bonded to titanium base (TiBase+LDS), zirconia abutment-crown bonded to titanium base (TiBase+ZR), polymer-infiltrated ceramic-network (PICN) abutment-crown bonded to titanium base (TiBase+PICN). Simultaneous thermocycling (5°-55°C) and chewing simulation (1,200,000-cycles, 49 N, 1.67 Hz) were applied. Catastrophic and non-catastrophic events were evaluated under light microscope, and survival and complication rates were calculated. Specimens that survived aging were loaded until failure and bending moments were calculated. RESULTS Survival rates after aging were 100% (TAbut+LDS, TiBase+LDS), 91.7% (GA-PFM), 66.7% (TiBase+ZR) and 58.3% (TiBase+PICN) and differed among the groups (p = .006). Non-catastrophic events as screw loosening (GA-PFM) and loss of retention or micro-/macro-movement (TiBase groups) were observed. Complication rates varied among the groups (p < .001). TiBase+PICN had lower bending moment than all the other groups (p < .001). CONCLUSIONS Hybrid abutment-crowns made of lithium disilicate can be an alternative to PFM-based restorations, although concerns regarding the bonded interface between the titanium base and abutment-crown can be raised. PICN and zirconia may not be recommended due to its inferior mechanical and bonding outcomes, respectively. Titanium customized abutment with bonded lithium disilicate crown appears to be the most stable combination.
Collapse
Affiliation(s)
- João Pitta
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Jenni Hjerppe
- Departments of Oral and Maxillofacial Diseases, Helsinki University Hospital (HUH), Helsinki, Finland.,Department of Prosthodontics and Stomatognathic physiology, University of Turku, Turku, Finland
| | - Felix Burkhardt
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Vincent Fehmer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Philippe Mojon
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
42
|
Arjunan A, Robinson J, Al Ani E, Heaselgrave W, Baroutaji A, Wang C. Mechanical performance of additively manufactured pure silver antibacterial bone scaffolds. J Mech Behav Biomed Mater 2020; 112:104090. [DOI: 10.1016/j.jmbbm.2020.104090] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 06/08/2020] [Accepted: 09/14/2020] [Indexed: 02/06/2023]
|
43
|
Borba M, Okamoto TK, Zou M, Kaizer MR, Zhang Y. Damage sensitivity of dental zirconias to simulated occlusal contact. Dent Mater 2020; 37:158-167. [PMID: 33234315 DOI: 10.1016/j.dental.2020.10.019] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 09/15/2020] [Accepted: 10/24/2020] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Mechanical damages can occur from dental restoration processing and fitting, or while it is in-service. This study evaluates the damage sensitivity of translucent zirconia (5Y-PSZ) relative to conventional 3Y-PSZ following mouth-motion simulations at various loads. METHODS 5Y-PSZ and 3Y-PSZ discs were adhesively bonded to a dentin-like substrate and divided into groups according to the load (50 N or 200 N) and number of cycles (up to 106) used in the chewing simulation. Specimens were mounted with 30° inclination in an electrodynamic mouth-motion simulator, and subjected to contact-slide-liftoff cyclic loading in water. Surface and sub-surface damages were analyzed using a sectioning technique. After the simulation, specimens were removed from the substrate and loaded with the damaged surface in tension for biaxial strength testing to assess their damage tolerance. RESULTS The strength of both ceramics underwent significant degradation after mouth-motion simulations. For 5Y-PSZ, the strength degradation was greater (∼60%) and occurred at a lower number of cycles than 3Y-PSZ. Herringbone cracks emerged on 3Y-PSZ and 5Y-PSZ surfaces under a 200-N load after 50 and 10 cycles, respectively. Meanwhile at a 50-N load, cracks formed at ∼1000 cycles in both ceramics. Further increasing the number of cycles only had moderate effects on the strength of both ceramics, despite an increase in surface and sub-surface damage. More significantly, a 50-N occlusal load can debase the zirconia strengths as much as a 200-N load. SIGNIFICANCE Surface flaws produced during the chewing simulation are capable of significant strength degradation in zirconia, even after a small number of low-load cycles.
Collapse
Affiliation(s)
- Marcia Borba
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA; Post-Graduate Program in Dentistry, University of Passo Fundo, BR 285, Km 292.7, Passo Fundo, RS 99052-900, Brazil
| | - Tomoyuki K Okamoto
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA
| | - Michelle Zou
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA; DDS Program, University at Buffalo School of Dental Medicine, 3435 Main St, Buffalo, NY 14214, USA
| | - Marina R Kaizer
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA; Post-Graduate Program in Dentistry, Positivo University, Professor Pedro Viriato Parigot de Souza Street, n. 5300, Ecoville, Curitiba, PR 81280-330, Brazil
| | - Yu Zhang
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA.
| |
Collapse
|
44
|
DE SOUZA RH, KAIZER MR, BORGES CEP, FERNANDES ABF, CORRER GM, DIÓGENES AN, ZHANG Y, GONZAGA CC. Flexural strength and crystalline stability of a monolithic translucent zirconia subjected to grinding, polishing and thermal challenges. CERAMICS INTERNATIONAL 2020; 46:26168-26175. [PMID: 33716378 PMCID: PMC7946154 DOI: 10.1016/j.ceramint.2020.07.114] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The objective of this study is to investigate the magnitude of structural degradation of a monolithic translucent zirconia caused by clinically relevant grinding and polishing procedures, when associated or not with low temperature degradation (LTD), induced by accelerated hydrothermal aging using autoclave or thermocycling Ninety disks (Ø12 × 1 mm) were prepared from dental zirconia for monolithic restorations (Vipi Block Zirconn Translucent, Vipi). The specimens were divided into 3 groups (n = 30) according to surface treatment: As Sintered (untreated), Grind (diamond bur), Grind + Polish (diamond bur + polish); and then subdivided according to aging method (n = 10): Baseline (no aging), Autoclave (134°C, 2.2 kgf/cm2 pressure for 5 h), and Thermocycling (200,000 cycles, 5°C and 55°C, for 15 s each). Roughness, biaxial flexural strength and percentage of monoclinic phase were evaluated. Regarding surface treatment, the Grind group presented higher roughness and greater flexural strength compared to As Sintered group, while Grind + Polish showed intermediate roughness and flexural strength similar to Grind group. Aging had little effect on roughness, but yielded a significant reduction in flexural strength. Tetragonal to monoclinic phase transformation was observed in all groups, caused by both mechanical stresses (grinding and polishing) and LTD, which was similarly induced by the traditional autoclave method, as well as the thermocycling method The use of diamond burs to grind zirconia surface may result in deleterious effects on the surface quality of monolithic zirconia restorations, yet has a potential toughening effect by phase transformation. However, when zirconia is exposed to LTD, regardless of the surface treatment, degradation of the surface quality and strength are observed.
Collapse
Affiliation(s)
- Raisa Hintz DE SOUZA
- School of Health Sciences, Graduate Program in Dentistry, Universidade Positivo, Curitiba, PR 81280, Brazil
| | - Marina R KAIZER
- School of Health Sciences, Graduate Program in Dentistry, Universidade Positivo, Curitiba, PR 81280, Brazil
| | | | | | - Gisele Maria CORRER
- School of Health Sciences, Graduate Program in Dentistry, Universidade Positivo, Curitiba, PR 81280, Brazil
| | | | - Yu ZHANG
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY 10010, USA
| | - Carla Castiglia GONZAGA
- School of Health Sciences, Graduate Program in Dentistry, Universidade Positivo, Curitiba, PR 81280, Brazil
| |
Collapse
|
45
|
Wear behavior and microstructural characterization of translucent multilayer zirconia. Dent Mater 2020; 36:1407-1417. [PMID: 32958309 DOI: 10.1016/j.dental.2020.08.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2020] [Revised: 07/12/2020] [Accepted: 08/29/2020] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To characterize the composition, microstructure and wear properties of a multilayer translucent zirconia relative to the conventional 3Y-TZP. METHODS Two types of ceramics were evaluated: a multilayer zirconia (MULTI, IPS e.max ZirCAD Multi, Ivoclar Vivadent) and a control 3Y-TZP (IPS e.max ZirCAD LT, Ivoclar Vivadent). Pre-sintered CAD-CAM blocks were cut, ground, sintered and polished to 1 μm finish. The phase fraction and grain size were measured using XRD and FE-SEM. For wear testing (n = 12), square-shaped specimens (16 × 16 × 1 mm) were adhesively bonded to a dentin analog. Sliding wear tests were performed using a spherical zirconia antagonist (r = 3.15 mm), with 30 N load at 1.5 Hz for 500,000 cycles in water. Optical and scanning electron microscopes and 3D laser scanner were used for quantitative wear analyses. Data were analyzed using Student's t-test (α = 0.05). RESULTS For MULTI, the enamel layer had the highest cubic content and the largest grain size, followed by the two transition layers, and the dentin layer. 3Y-TZP showed the smallest grain size and cubic content. A significant amount of wear was observed in both materials up to 50,000 cycles until it reached a plateau. MULTI showed higher volume loss and greater wear depth than 3Y-TZP (p < 0.01). The higher volume loss was associated with extensive lateral fracture, leading to material spalling from the surface of cubic-containing zirconias. SIGNIFICANCE The wear pattern in multi-layered zirconia was more severe than 3Y-TZP. Additionally, the different layers of the multi-layered zirconia had similar wear behavior.
Collapse
|
46
|
Karlsen CÅ, Schriwer C, Øilo M. Damage tolerance of six dental zirconias with different translucencies. Biomater Investig Dent 2020; 7:126-133. [PMID: 32939457 PMCID: PMC7470024 DOI: 10.1080/26415275.2020.1809420] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Purpose High-translucent dental zirconia has been introduced as a suitable material for anterior monolithic restorations. The material composition differs from traditional 3Y-TZP both with regard to yttria content and grain size. Little is known regarding how these alterations affect other properties than translucency and flexural strength. The aim of this study was to evaluate the crack propagation resistance and hardness of dental zirconias with different yttria content and different manufacturing methods. Materials and methods Measurement of hardness (HV2/5) and crack propagation from the indents (damage tolerance) was performed using a hardness tester(Vicker) on a flat polished surface of five crowns from six different commercial dental zirconias; one hard-machined 3Y-TZP, three soft-machined 3-5% yttria-stabilized zirconias and two soft-machined zirconias with ≥5% yttria content. Results Damage control varied greatly among dental zirconias with different compositions and fabrication methods. The hard-machined 3Y-TZP had better crack propagation resistance than soft-machined, 3-5% yttria-stabilized zirconias Conslusion The ultra-translucent zirconias with ≥5% yttria content had the lowest crack propagation resistance. Hardness is not a suitable indicator for damage tolerance.
Collapse
Affiliation(s)
- Cathrine Å Karlsen
- Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Bergen, Norway
| | - Christian Schriwer
- Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Bergen, Norway
| | - Marit Øilo
- Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Bergen, Norway
| |
Collapse
|
47
|
Kim HK. Optical and Mechanical Properties of Highly Translucent Dental Zirconia. MATERIALS 2020; 13:ma13153395. [PMID: 32751942 PMCID: PMC7435650 DOI: 10.3390/ma13153395] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 07/29/2020] [Accepted: 07/30/2020] [Indexed: 12/18/2022]
Abstract
The aim was to evaluate the translucency, opalescence, and fluorescence of highly translucent zirconia, lithium disilicate, and bovine teeth. One mm-thick specimens of five monolithic zirconia systems, two glass-ceramics, and bovine enamel/dentin were investigated. A spectrophotometer (Ci7600) was used to measure the CIELab color coordinates, and the translucency and opalescence values were obtained. For evaluating the fluorescence emission, the differences in spectral reflectance by the UV component of illumination were calculated. The microstructures of ceramic specimens were examined with a scanning electron microscope and the chemical compositions were determined with an X-ray fluorescence spectrometer. Mechanical properties were appraised with three-point bending strength, indentation fracture toughness, and Vickers hardness. Data were analyzed using a one-way ANOVA, followed by Tukey’s multiple comparison test (α = 0.05). A higher yttria content (5 mol%) significantly improved the translucency of zirconia ceramics, while they were less translucent than lithium disilicate (p < 0.05). Lowering the alumina content below 0.05 wt.% enhanced the translucency (p < 0.05), but a small amount of alumina was still required to obtain full densification. 0.05 wt.% Fe was used to increase the chroma of zirconia specimens without compromising their mechanical properties. The Er-containing zirconia specimen showed a maximal fluorescence emission at 430 nm. The degree of opalescence was affected by the microstructures of ceramic materials. The microstructure, incorporation of a secondary phase, and sintering behavior can have a strong impact on the final mechanical and optical properties of dental ceramics. Addition of small amounts of metal oxides can affect the translucency, opalescence or fluorescence qualities of zirconia
Collapse
Affiliation(s)
- Hee-Kyung Kim
- Department of Prosthodontics, Institute of Oral Health Science, Ajou University School of Medicine, Suwon 16499, Korea
| |
Collapse
|
48
|
Dejak B, Młotkowski A. A comparison of mvM stress of inlays, onlays and endocrowns made from various materials and their bonding with molars in a computer simulation of mastication - FEA. Dent Mater 2020; 36:854-864. [PMID: 32473834 DOI: 10.1016/j.dental.2020.04.007] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2020] [Accepted: 04/14/2020] [Indexed: 12/13/2022]
Abstract
OBJECTIVES The purpose of the study was to compare the mvM stresses occurring in inlays, onlays and endocrowns made from different materials and their bonding with molars in a computer simulation of mastication. METHODS The study was conducted using the finite elements method with contact elements. Sixteen 3D first molar models were created of a intact tooth - T; a tooth with a ceramic inlay - IN; a tooth with an onlay - ON; and a tooth with an endocrown - EN. The restorations were made of: Comp - resin nanoceramic; Hc - hybrid ceramic; Le - leucite ceramic; Dlit - lithium disilicate; and Zr - zirconia. Computer simulations of mastication were performed. The equivalent stresses according to the modified von Mises criterion (mvM) were calculated in model materials and contact stresses at the interface cement-dental tissue around the examined restorations. RESULTS The highest equivalent mvM stresses were concentrated in buccal margins of inlays. The mvM stresses recorded in onlays were 1.6-5 times lower than those found in inlays, while in endocrowns they were 2.3-6.5 times lower. Around the onlays and endocrowns, in tooth structures and luting cement, mvM stresses were significantly lower compared to teeth restored with inlays. The tensile and shear contact stresses between inlays and teeth were several times lower than under another restorations. The highest stresses (58.5MPa) occurred in the zirconia inlay. The stresses observed in the enamel of a tooth restored with an INZr inlay were half those noted in INComp, and a third of those observed in cement. Tensile contact stresses at the interface between the INZr inlay and dental tissue were 4.5 times lower than in the INComp, and the shear stresses were more than 7 times lower. SIGNIFICANCE The highest values and unfavorable of stress levels occurred in teeth restored with inlays. Cavities MOD in molars should be reconstructed with cusp-covering restorations. The endocrown in molars should withstand physiological loading. The higher the modulus of elasticity of the restoration material, the higher the stresses in the restorations, while the lower stresses were observed in the tooth structures, luting cement and at the interface between the restoration and the dental tissue. Ceramic restorations should provide better protection and marginal seal of the reconstructed tooth than composite ones.
Collapse
Affiliation(s)
- Beata Dejak
- Department of Prosthetic Dentistry, Medical University of Łódź, Łódź, Poland.
| | - Andrzej Młotkowski
- Department of Strength of Materials and Structures, Technical University of Łódź, Łódź, Poland
| |
Collapse
|
49
|
Zhang F, Van Meerbeek B, Vleugels J. Importance of tetragonal phase in high-translucent partially stabilized zirconia for dental restorations. Dent Mater 2020; 36:491-500. [DOI: 10.1016/j.dental.2020.01.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 12/16/2019] [Accepted: 01/14/2020] [Indexed: 02/04/2023]
|
50
|
Zogheib LV, Lopes GR, Matos JD, Castro DS, Bottino MA, McCabe J, Kimpara ET. Effect of neutralization and hydrofluoric acid precipitate remotion on the compressive strength of monolithic lithium disilicate crowns. Minerva Dent Oral Sci 2020; 70:133-141. [PMID: 32181616 DOI: 10.23736/s2724-6329.20.04330-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The cleaning protocol for the ceramic surface after acid etching resulted in a decrease in bond strength and flexural strength of a glass ceramic. This study aims to evaluate the effect of different ceramic surface treatments after hydrofluoric acid etching (HF) on the compressive strength of monolithic lithium disilicate crowns. METHODS Forty (40) human third molars received conventional full coverage preparation. After performing digital impressions of teeth preparations, ceramic blocks were machined using a CAD/CAM system in order to obtain the crowns. The crowns were distributed in 4 groups as ceramic surface treatment (N.=10): (HF) - 4.9% HF for 20s + air-water spray for 30s; (HFN) - HF + neutralizing agent for 5 min (N); (HFU) - HF + ultrasonic bath for 5 min (U); e (HFNU) - HF + N + U. SEM and EDS analysis was performed in each group in order to characterize the ceramic surface and to verify the chemical element distribution after HF cleaning protocols. A silane layer was applied (for 60s), and crowns were then cemented with dual resin cement. A compressive load was applied on the middle of the occlusal crown surface with a crosshead speed of 1 mm/min until fracture. Data were analyzed using ANOVA and Tukey test (α=0.05). RESULTS Fluoride ions were found in samples of all postetching cleaning protocols. The mean value (Kgf) was: HF =169.92±21.37; HFN =187.34±34.79; HFU =166.63±40.22 and HFNU=175.26±40.22. The ceramic surface treatment after HF etching did not significantly influence (P>0.05) the compressive strength of the tested ceramic crowns. CONCLUSIONS Surface treatments with neutralizing agent associated with the ultrasonic bath as the pre-cementation protocol was the most efficient protocol in eliminating the precipitate deposited on the porosities created by acid etching.
Collapse
Affiliation(s)
- Lucas V Zogheib
- Department of Dentistry, University of Fortaleza (UNIFOR), Fortaleza, Brazil
| | - Guilherme R Lopes
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, Brazil -
| | - Jefferson D Matos
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, Brazil
| | - Daniel S Castro
- Department of Dentistry, University Center Christus (UNICHRISTUS), Fortaleza, Brazil
| | - Marco A Bottino
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, Brazil
| | - John McCabe
- School of Dental Science, Newcastle University, Newcastle, UK
| | - Estevão T Kimpara
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, Brazil
| |
Collapse
|