1
|
Colmenarez JA, Dong P, Lee J, Wilson DL, Gu L. Evaluating the Influence of Morphological Features on the Vulnerability of Lipid-Rich Plaques During Stenting. J Biomech Eng 2025; 147:021007. [PMID: 39665787 DOI: 10.1115/1.4067398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Accepted: 12/05/2024] [Indexed: 12/13/2024]
Abstract
Lipid-rich atheromas are linked to plaque rupture in stented atherosclerotic arteries. While fibrous cap thickness is acknowledged as a critical indicator of vulnerability, it is likely that other morphological features also exert influence. However, detailed quantifications of their contributions and intertwined effects in stenting are lacking. Therefore, our goal is to assess the impact of plaque characteristics on the fibrous cap stress and elucidate their underlying mechanisms. We analyzed the stent deployment in a three-dimensional patient-specific coronary artery reconstructed from intravascular optical coherence tomography (IVOCT) data using the finite element method. Additionally, we performed sensitivity analysis on 78,000 distinct plaque geometries of two-dimensional arterial cross section for verification. Results from the three-dimensional patient-specific model indicate strong correlations between maximum fibrous cap stress and lipid arc (r=0.769), area stenosis (r=0.550), and lumen curvature (r=0.642). Plaques with lipid arcs >60 deg, area stenosis >75%, and lumen curvatures >5 mm-1 are at rupture risk. While we observed a rise in stress with thicker lipid cores, it was less representative than other features. Fibrous cap thickness showed a poor correlation, with the sensitivity analysis revealing its significance only when high stretches are induced by other features, likely due to its J-shaped stress-stretch response. Contrary to physiological pressure, the stent expansion generates unique vulnerable features as the stent load-transferring characteristics modify the plaque's response. This study is expected to prompt further clinical investigations of other morphological features for predicting plaque rupture in stenting.
Collapse
Affiliation(s)
- Jose A Colmenarez
- Department of Biomedical Engineering and Science, Florida Institute of Technology, 150 West University Boulevard, Melbourne, FL 32901
| | - Pengfei Dong
- Department of Biomedical Engineering and Science, Florida Institute of Technology, 150 West University Boulevard, Melbourne, FL 32901
| | - Juhwan Lee
- Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106
| | - David L Wilson
- Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106
| | - Linxia Gu
- Department of Biomedical Engineering and Science, Florida Institute of Technology, 150 West University Boulevard, Melbourne, FL 32901
| |
Collapse
|
2
|
Guendouz Y, Razif NAM, Bernasconi F, Brien GO, Johnston RD, Lally C. Simulating atherosclerotic plaque mechanics using polyvinyl alcohol (PVA) cryogel artery phantoms, ultrasound imaging and inverse finite element analysis. Phys Med Biol 2024; 69:245020. [PMID: 39626619 DOI: 10.1088/1361-6560/ad9a4b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Accepted: 12/03/2024] [Indexed: 12/20/2024]
Abstract
The clinical decision to establish if a patient with carotid disease should undergo surgical intervention is primarily based on the percent stenosis. Whilst this applies for high-grade stenosed vessels (>70%), it falls short for other cases. Due to the heterogeneity of plaque tissue, probing the mechanics of the tissue would likely provide further insights into why some plaques are more prone to rupture. Mechanical characterization of such tissue is nontrivial, however, due to the difficulties in collecting fresh, intact plaque tissue and using physiologically relevant mechanical testing of such material. The use of polyvinyl alcohol (PVA) cryogel is thus highly convenient because of its acoustic properties and tunable mechanical properties.Methods.The aim of this study is to demonstrate the potential of PVA phantoms to simulate atherosclerotic features. In addition, a testing and simulation framework is developed for full PVA vessel material characterization using ring tensile testing and inflation testing combined with non-invasive ultrasound imaging and computational modeling.Results.Strain stiffening behavior was observed in PVA through ring tensile tests, particularly at high (n= 6) freeze-thaw cycles (FTCs). Inflation testing of bi-layered phantoms featuring lipid pool inclusions demonstrated high strains at shoulder regions. The application of an inverse finite element framework successfully recovered boundaries and determined the shear moduli for the PVA wall to lie within the range 27-53 kPa.Conclusion.The imaging-modeling framework presented facilitates the use and characterization of arterial mimicking phantoms to further explore plaque rupture. It also shows translational potential for non-invasive mechanical characterization of atherosclerotic plaques to improve the identification of clinically relevant metrics of plaque vulnerability.
Collapse
Affiliation(s)
- Yasmine Guendouz
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
| | - Noor Adeebah Mohamed Razif
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
| | - Floriane Bernasconi
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
| | - Gordon O' Brien
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
| | - Robert D Johnston
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
- Advanced Materials and Bioengineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin, Ireland
| | - Caitríona Lally
- Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland
- Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin, Ireland
- Advanced Materials and Bioengineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin, Ireland
| |
Collapse
|
3
|
Vuong TNAM, Bartolf‐Kopp M, Andelovic K, Jungst T, Farbehi N, Wise SG, Hayward C, Stevens MC, Rnjak‐Kovacina J. Integrating Computational and Biological Hemodynamic Approaches to Improve Modeling of Atherosclerotic Arteries. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2307627. [PMID: 38704690 PMCID: PMC11234431 DOI: 10.1002/advs.202307627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 03/12/2024] [Indexed: 05/07/2024]
Abstract
Atherosclerosis is the primary cause of cardiovascular disease, resulting in mortality, elevated healthcare costs, diminished productivity, and reduced quality of life for individuals and their communities. This is exacerbated by the limited understanding of its underlying causes and limitations in current therapeutic interventions, highlighting the need for sophisticated models of atherosclerosis. This review critically evaluates the computational and biological models of atherosclerosis, focusing on the study of hemodynamics in atherosclerotic coronary arteries. Computational models account for the geometrical complexities and hemodynamics of the blood vessels and stenoses, but they fail to capture the complex biological processes involved in atherosclerosis. Different in vitro and in vivo biological models can capture aspects of the biological complexity of healthy and stenosed vessels, but rarely mimic the human anatomy and physiological hemodynamics, and require significantly more time, cost, and resources. Therefore, emerging strategies are examined that integrate computational and biological models, and the potential of advances in imaging, biofabrication, and machine learning is explored in developing more effective models of atherosclerosis.
Collapse
Affiliation(s)
| | - Michael Bartolf‐Kopp
- Department of Functional Materials in Medicine and DentistryInstitute of Functional Materials and Biofabrication (IFB)KeyLab Polymers for Medicine of the Bavarian Polymer Institute (BPI)University of WürzburgPleicherwall 297070WürzburgGermany
| | - Kristina Andelovic
- Department of Functional Materials in Medicine and DentistryInstitute of Functional Materials and Biofabrication (IFB)KeyLab Polymers for Medicine of the Bavarian Polymer Institute (BPI)University of WürzburgPleicherwall 297070WürzburgGermany
| | - Tomasz Jungst
- Department of Functional Materials in Medicine and DentistryInstitute of Functional Materials and Biofabrication (IFB)KeyLab Polymers for Medicine of the Bavarian Polymer Institute (BPI)University of WürzburgPleicherwall 297070WürzburgGermany
- Department of Orthopedics, Regenerative Medicine Center UtrechtUniversity Medical Center UtrechtUtrecht3584Netherlands
| | - Nona Farbehi
- Graduate School of Biomedical EngineeringUniversity of New South WalesSydney2052Australia
- Tyree Institute of Health EngineeringUniversity of New South WalesSydneyNSW2052Australia
- Garvan Weizmann Center for Cellular GenomicsGarvan Institute of Medical ResearchSydneyNSW2010Australia
| | - Steven G. Wise
- School of Medical SciencesUniversity of SydneySydneyNSW2006Australia
| | - Christopher Hayward
- St Vincent's HospitalSydneyVictor Chang Cardiac Research InstituteSydney2010Australia
| | | | - Jelena Rnjak‐Kovacina
- Graduate School of Biomedical EngineeringUniversity of New South WalesSydney2052Australia
- Tyree Institute of Health EngineeringUniversity of New South WalesSydneyNSW2052Australia
- Australian Centre for NanoMedicine (ACN)University of New South WalesSydneyNSW2052Australia
| |
Collapse
|
4
|
Shahbad R, Pipinos M, Jadidi M, Desyatova A, Gamache J, MacTaggart J, Kamenskiy A. Structural and Mechanical Properties of Human Superficial Femoral and Popliteal Arteries. Ann Biomed Eng 2024; 52:794-815. [PMID: 38321357 PMCID: PMC11455778 DOI: 10.1007/s10439-023-03435-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Accepted: 12/26/2023] [Indexed: 02/08/2024]
Abstract
The femoropopliteal artery (FPA) is the main artery in the lower limb. It supplies blood to the leg muscles and undergoes complex deformations during limb flexion. Atherosclerotic disease of the FPA (peripheral arterial disease, PAD) is a major public health burden, and despite advances in surgical and interventional therapies, the clinical outcomes of PAD repairs continue to be suboptimal, particularly in challenging calcified lesions and biomechanically active locations. A better understanding of human FPA mechanical and structural characteristics in relation to age, risk factors, and the severity of vascular disease can help develop more effective and longer-lasting treatments through computational modeling and device optimization. This review aims to summarize recent research on the main biomechanical and structural properties of human superficial femoral and popliteal arteries that comprise the FPA and describe their anatomy, composition, and mechanical behavior under different conditions.
Collapse
Affiliation(s)
- Ramin Shahbad
- Department of Biomechanics, University of Nebraska at Omaha, Biomechanics Research Building, Omaha, NE, 68182, USA
| | - Margarita Pipinos
- Department of Biomechanics, University of Nebraska at Omaha, Biomechanics Research Building, Omaha, NE, 68182, USA
| | - Majid Jadidi
- Department of Biomechanics, University of Nebraska at Omaha, Biomechanics Research Building, Omaha, NE, 68182, USA
| | - Anastasia Desyatova
- Department of Biomechanics, University of Nebraska at Omaha, Biomechanics Research Building, Omaha, NE, 68182, USA
| | - Jennifer Gamache
- Department of Surgery, University of Nebraska Medical Center, Omaha, NE, 68198, USA
| | - Jason MacTaggart
- Department of Surgery, University of Nebraska Medical Center, Omaha, NE, 68198, USA
| | - Alexey Kamenskiy
- Department of Biomechanics, University of Nebraska at Omaha, Biomechanics Research Building, Omaha, NE, 68182, USA.
| |
Collapse
|
5
|
Feng H, Shi X, Wang T, Wang K, Su J. A comparative study on the deformation behavior and mechanical properties of new lower extremity arterial stents. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 247:108094. [PMID: 38401508 DOI: 10.1016/j.cmpb.2024.108094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Revised: 02/04/2024] [Accepted: 02/17/2024] [Indexed: 02/26/2024]
Abstract
BACKGROUND AND OBJECTIVE The lower extremity movement involves a complex and large amplitude extremity movement process, and arterial stents implanted in the lower extremity are prone to complex mechanical deformation behavior. Hence, the lower extremity arterial stent is required to have favorable comprehensive mechanical properties. METHODS In this study, a new lower extremity arterial stent (New) was proposed, and its deformation behavior and mechanical properties were analyzed by numerical simulations under different deformation modes, such as radial compression, axial compression/tension, bending, and torsion. Stents with different diameters were modeled to compare the effect of diameter size on their biomechanical properties. Additionally, a comparative analysis was conducted between this new stent and seven commercially available stents. RESULTS The results demonstrated that the stent diameter exerted a significant effect on its deformation behavior and mechanical properties. Specifically, with the increase of the stent diameter, the radial expansion rate, radial shrinkage rate, radial support stiffness, axial compression stiffness, and axial tensile stiffness tended to decrease, and the expansion inhomogeneity, stenosis rate, bending stiffness, and torsional stiffness tended to increase. In contrast, the stent diameter exerted a small effect on the stent axial shortening rate and ellipticity. The new lower extremity arterial stent was validated to outperform other stents in terms of most performance indicators. Especially, the radial expansion rate and ellipticity of the New stent were better than those of all commercially available stents. Moreover, the New stent presented favorable mechanical properties and flexibility under the premise of ensuring the support performance. CONCLUSIONS Based on these findings, this lower extremity arterial stent may play a better therapeutic effect in clinical application. Furthermore, these analysis results may provide reference for the clinical application and selection of the stent.
Collapse
Affiliation(s)
- Haiquan Feng
- College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot 010000, PR China
| | - Xinyuan Shi
- College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot 010000, PR China
| | - Tianqi Wang
- College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot 010000, PR China
| | - Kun Wang
- College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot 010000, PR China
| | - Juan Su
- School of Materials Science and Engineering, Inner Mongolia University of Technology, Hohhot 010051, PR China.
| |
Collapse
|
6
|
Zuo D, Chen D, Zhu M, Xue Q. Sensitivity analysis of the mechanical properties on atherosclerotic arteries rupture risk with an artificial neural network method. Comput Methods Biomech Biomed Engin 2024:1-12. [PMID: 38268436 DOI: 10.1080/10255842.2024.2305862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Accepted: 12/28/2023] [Indexed: 01/26/2024]
Abstract
Considering the differences between individuals, in this paper, an uncertainty analysis model for predicting rupture risk of atherosclerotic arteries is established based on a back-propagation artificial neural network. The influence of isotropy and anisotropy on the rupture risk of atherosclerotic arteries is analyzed, and the results demonstrate the effectiveness of the artificial neural network in predicting the rupture risk. Moreover, the rupture risk of atherosclerotic arteries at different inflation sizes are simulated. This study contributes to a better understanding of the underlying mechanisms of atherosclerotic arteries rupture and promotes the advancement of artificial neural networks in atherosclerosis research.
Collapse
Affiliation(s)
- Di Zuo
- Department of Engineering Mechanics, Dalian Jiaotong University, P.R. China
| | - Daye Chen
- Department of Engineering Mechanics, Dalian Jiaotong University, P.R. China
| | - Mingji Zhu
- Department of Engineering Mechanics, Dalian Jiaotong University, P.R. China
| | - Qiwen Xue
- Department of Engineering Mechanics, Dalian Jiaotong University, P.R. China
| |
Collapse
|
7
|
Latorre ÁT, Martínez MA, Peña E. Characterizing atherosclerotic tissues: in silico analysis of mechanical properties using intravascular ultrasound and inverse finite element methods. Front Bioeng Biotechnol 2023; 11:1304278. [PMID: 38152285 PMCID: PMC10751321 DOI: 10.3389/fbioe.2023.1304278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 11/27/2023] [Indexed: 12/29/2023] Open
Abstract
Atherosclerosis is a prevalent cause of acute coronary syndromes that consists of lipid deposition inside the artery wall, creating an atherosclerotic plaque. Early detection may prevent the risk of plaque rupture. Nowadays, intravascular ultrasound (IVUS) is the most common medical imaging technology for atherosclerotic plaque detection. It provides an image of the section of the coronary wall and, in combination with new techniques, can estimate the displacement or strain fields. From these magnitudes and by inverse analysis, it is possible to estimate the mechanical properties of the plaque tissues and their stress distribution. In this paper, we presented a methodology based on two approaches to characterize the mechanical properties of atherosclerotic tissues. The first approach estimated the linear behavior under particular pressure. In contrast, the second technique yielded the non-linear hyperelastic material curves for the fibrotic tissues across the complete physiological pressure range. To establish and validate this method, the theoretical framework employed in silico models to simulate atherosclerotic plaques and their IVUS data. We analyzed different materials and real geometries with finite element (FE) models. After the segmentation of the fibrotic, calcification, and lipid tissues, an inverse FE analysis was performed to estimate the mechanical response of the tissues. Both approaches employed an optimization process to obtain the mechanical properties by minimizing the error between the radial strains obtained from the simulated IVUS and those achieved in each iteration. The second methodology was successfully applied to five distinct real geometries and four different fibrotic tissues, getting median R 2 of 0.97 and 0.92, respectively, when comparing the real and estimated behavior curves. In addition, the last technique reduced errors in the estimated plaque strain field by more than 20% during the optimization process, compared to the former approach. The findings enabled the estimation of the stress field over the hyperelastic plaque tissues, providing valuable insights into its risk of rupture.
Collapse
Affiliation(s)
- Álvaro T. Latorre
- Aragón Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
| | - Miguel A. Martínez
- Aragón Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain
| | - Estefanía Peña
- Aragón Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain
| |
Collapse
|
8
|
Kriener K, Whiting H, Storr N, Homes R, Lala R, Gabrielyan R, Kuang J, Rubin B, Frails E, Sandstrom H, Futter C, Midwinter M. Applied use of biomechanical measurements from human tissues for the development of medical skills trainers: a scoping review. JBI Evid Synth 2023; 21:2309-2405. [PMID: 37732940 DOI: 10.11124/jbies-22-00363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
OBJECTIVE The objective of this review was to identify quantitative biomechanical measurements of human tissues, the methods for obtaining these measurements, and the primary motivations for conducting biomechanical research. INTRODUCTION Medical skills trainers are a safe and useful tool for clinicians to use when learning or practicing medical procedures. The haptic fidelity of these devices is often poor, which may be because the synthetic materials chosen for these devices do not have the same mechanical properties as human tissues. This review investigates a heterogeneous body of literature to identify which biomechanical properties are available for human tissues, the methods for obtaining these values, and the primary motivations behind conducting biomechanical tests. INCLUSION CRITERIA Studies containing quantitative measurements of the biomechanical properties of human tissues were included. Studies that primarily focused on dynamic and fluid mechanical properties were excluded. Additionally, studies only containing animal, in silico , or synthetic materials were excluded from this review. METHODS This scoping review followed the JBI methodology for scoping reviews and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). Sources of evidence were extracted from CINAHL (EBSCO), IEEE Xplore, MEDLINE (PubMed), Scopus, and engineering conference proceedings. The search was limited to the English language. Two independent reviewers screened titles and abstracts as well as full-text reviews. Any conflicts that arose during screening and full-text review were mediated by a third reviewer. Data extraction was conducted by 2 independent reviewers and discrepancies were mediated through discussion. The results are presented in tabular, figure, and narrative formats. RESULTS Data were extracted from a total of 186 full-text publications. All of the studies, except for 1, were experimental. Included studies came from 33 countries, with the majority coming from the United States. Ex vivo methods were the predominant approach for extracting human tissue samples, and the most commonly studied tissue type was musculoskeletal. In this study, nearly 200 unique biomechanical values were reported, and the most commonly reported value was Young's (elastic) modulus. The most common type of mechanical test performed was tensile testing, and the most common reason for testing human tissues was to characterize biomechanical properties. Although the number of published studies on biomechanical properties of human tissues has increased over the past 20 years, there are many gaps in the literature. Of the 186 included studies, only 7 used human tissues for the design or validation of medical skills training devices. Furthermore, in studies where biomechanical values for human tissues have been obtained, a lack of standardization in engineering assumptions, methodologies, and tissue preparation may implicate the usefulness of these values. CONCLUSIONS This review is the first of its kind to give a broad overview of the biomechanics of human tissues in the published literature. With respect to high-fidelity haptics, there is a large gap in the published literature. Even in instances where biomechanical values are available, comparing or using these values is difficult. This is likely due to the lack of standardization in engineering assumptions, testing methodology, and reporting of the results. It is recommended that journals and experts in engineering fields conduct further research to investigate the feasibility of implementing reporting standards. REVIEW REGISTRATION Open Science Framework https://osf.io/fgb34.
Collapse
Affiliation(s)
- Kyleigh Kriener
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Harrison Whiting
- Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
- School of Clinical Medicine, Royal Brisbane Clinical Unit, The University of Queensland, Brisbane, QLD, Australia
| | - Nicholas Storr
- Gold Coast University Hospital, Southport, QLD Australia
| | - Ryan Homes
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Raushan Lala
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Robert Gabrielyan
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Jasmine Kuang
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Bryn Rubin
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Edward Frails
- Department of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA, United States
| | - Hannah Sandstrom
- Department of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA, United States
| | - Christopher Futter
- Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
- Anaesthesia and Intensive Care Program, Herston Biofabrication institute, Brisbane, QLD, Australia
| | - Mark Midwinter
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| |
Collapse
|
9
|
Zhao S, Wang H, Zou J, Zhang A. A coupled thermal-electrical-structural model for balloon-based thermoplasty treatment of atherosclerosis. Int J Hyperthermia 2023; 40:2122597. [PMID: 36642421 DOI: 10.1080/02656736.2022.2122597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023] Open
Abstract
OBJECTIVES The outcome of balloon-based atherosclerosis thermoplasty is closely related to the temperature/stress distribution during the treatment. For precise prediction of a required thermal lesion in the heterogeneous and thin atherosclerotic vessel, a numerical model incorporating heat-induced tissue expansion or shrinkage and the strain caused by balloon dilation is necessary. METHODS A fully coupled thermal-electrical-structural new model was established. The model features a heterogeneous structure including eccentric plaque, healthy artery and surrounding tissue. Tissue expansion/shrinkage and hyperelasticity material model were taken into consideration. Different heating strategies and plaque mechanical properties were investigated. The temperature distribution was compared with the traditional thermal-electrical coupled model. The possibility of thermoplasty treatment using balloons with different sizes was also explored. RESULTS The temperature, the electrical intensity and the stress during the thermoplasty were obtained. Lower stress was found in the heating region where tissue shrinkage occurred. The ablation depth was predicted to be ∼0.42 mm larger without coupling the biomechanical influence. The mechanical properties and input condition significantly affect the temperature and stress distribution considering the small dimensions of the tissue. Besides, with a 12.5% reduction of balloon diameter, the largest Von Mises stress decreases by 25.4%. CONCLUSIONS It is confirmed that a coupled thermal-electrical-structural model is needed for precise temperature prediction in the balloon-based thermoplasty of the heterogeneous and thin tissue. The model presented may help with future development of optimized treatment planning considering both ablation depth and minimum stress.
Collapse
Affiliation(s)
- Shiqing Zhao
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Hongying Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Jincheng Zou
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Aili Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
| |
Collapse
|
10
|
Warren JL, Yoo JE, Meyer CA, Molony DS, Samady H, Hayenga HN. Automated finite element approach to generate anatomical patient-specific biomechanical models of atherosclerotic arteries from virtual histology-intravascular ultrasound. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 4:1008540. [PMID: 36523426 PMCID: PMC9745200 DOI: 10.3389/fmedt.2022.1008540] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 11/07/2022] [Indexed: 11/16/2023] Open
Abstract
Despite advancements in early detection and treatment, atherosclerosis remains the leading cause of death across all cardiovascular diseases (CVD). Biomechanical analysis of atherosclerotic lesions has the potential to reveal biomechanically instable or rupture-prone regions. Treatment decisions rarely consider the biomechanics of the stenosed lesion due in-part to difficulties in obtaining this information in a clinical setting. Previous 3D FEA approaches have incompletely incorporated the complex curvature of arterial geometry, material heterogeneity, and use of patient-specific data. To address these limitations and clinical need, herein we present a user-friendly fully automated program to reconstruct and simulate the wall mechanics of patient-specific atherosclerotic coronary arteries. The program enables 3D reconstruction from patient-specific data with heterogenous tissue assignment and complex arterial curvature. Eleven arteries with coronary artery disease (CAD) underwent baseline and 6-month follow-up angiographic and virtual histology-intravascular ultrasound (VH-IVUS) imaging. VH-IVUS images were processed to remove background noise, extract VH plaque material data, and luminal and outer contours. Angiography data was used to orient the artery profiles along the 3D centerlines. The resulting surface mesh is then resampled for uniformity and tetrahedralized to generate the volumetric mesh using TetGen. A mesh convergence study revealed edge lengths between 0.04 mm and 0.2 mm produced constituent volumes that were largely unchanged, hence, to save computational resources, a value of 0.2 mm was used throughout. Materials are assigned and finite element analysis (FEA) is then performed to determine stresses and strains across the artery wall. In a representative artery, the highest average effective stress was in calcium elements with 235 kPa while necrotic elements had the lowest average stress, reaching as low as 0.79 kPa. After applying nodal smoothening, the maximum effective stress across 11 arteries remained below 288 kPa, implying biomechanically stable plaques. Indeed, all atherosclerotic plaques remained unruptured at the 6-month longitudinal follow up diagnosis. These results suggest our automated analysis may facilitate assessment of atherosclerotic plaque stability.
Collapse
Affiliation(s)
- Jeremy L. Warren
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States
| | - John E. Yoo
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States
| | - Clark A. Meyer
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States
| | - David S. Molony
- Northeast Georgia Health System, Georgia Heart Institute, Gainesville, GA, United States
| | - Habib Samady
- Northeast Georgia Health System, Georgia Heart Institute, Gainesville, GA, United States
| | - Heather N. Hayenga
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States
| |
Collapse
|
11
|
Cheng H, Li G, Dai J, Zhang K, Xu T, Wei L, Zhang X, Ding D, Hou J, Li J, Zhuang J, Tan K, Guo R. A fluid-structure interaction model accounting arterial vessels as a key part of the blood-flow engine for the analysis of cardiovascular diseases. Front Bioeng Biotechnol 2022; 10:981187. [PMID: 36061431 PMCID: PMC9438578 DOI: 10.3389/fbioe.2022.981187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 07/28/2022] [Indexed: 11/13/2022] Open
Abstract
According to the classical Windkessel model, the heart is the only power source for blood flow, while the arterial system is assumed to be an elastic chamber that acts as a channel and buffer for blood circulation. In this paper we show that in addition to the power provided by the heart for blood circulation, strain energy stored in deformed arterial vessels in vivo can be transformed into mechanical work to propel blood flow. A quantitative relationship between the strain energy increment and functional (systolic, diastolic, mean and pulse blood pressure) and structural (stiffness, diameter and wall thickness) parameters of the aorta is described. In addition, details of blood flow across the aorta remain unclear due to changes in functional and other physiological parameters. Based on the arterial strain energy and fluid-structure interaction theory, the relationship between physiological parameters and blood supply to organs was studied, and a corresponding mathematical model was developed. The findings provided a new understanding about blood-flow circulation, that is, cardiac output allows blood to enter the aorta at an initial rate, and then strain energy stored in the elastic arteries pushes blood toward distal organs and tissues. Organ blood supply is a key factor in cardio-cerebrovascular diseases (CCVD), which are caused by changes in blood supply in combination with multiple physiological parameters. Also, some physiological parameters are affected by changes in blood supply, and vice versa. The model can explain the pathophysiological mechanisms of chronic diseases such as CCVD and hypertension among others, and the results are in good agreement with epidemiological studies of CCVD.
Collapse
Affiliation(s)
- Heming Cheng
- Department of Mechanics, Kunming University of Science and Technology, Kunming, China
- *Correspondence: Heming Cheng, ; Ke Zhang,
| | - Gen Li
- Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming, China
| | - Jifeng Dai
- Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming, China
| | - Ke Zhang
- Department of Mechanics, Kunming University of Science and Technology, Kunming, China
- Department of Hydraulic Engineering, Kunming University of Science and Technology, Kunming, China
- *Correspondence: Heming Cheng, ; Ke Zhang,
| | - Tianrui Xu
- Faculty of Life Science and Technology, Kunming University of Science and Technology, Kunming, China
| | - Liuchuang Wei
- Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming, China
| | - Xue Zhang
- Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming, China
| | - Dongfang Ding
- Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming, China
| | - Jie Hou
- Department of Mechanics, Kunming University of Science and Technology, Kunming, China
| | - Jianyun Li
- Department of Mechanics, Kunming University of Science and Technology, Kunming, China
| | - Jiangping Zhuang
- Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming, China
| | - Kaijun Tan
- Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming, China
| | - Ran Guo
- Department of Mechanics, Kunming University of Science and Technology, Kunming, China
| |
Collapse
|
12
|
Nooraeen A, Ghalichi F, Taghizadeh H, Guidoin R. Probing the possibility of lesion formation/progression in vicinity of a primary atherosclerotic plaque: A fluid-solid interaction study and angiographic evidences. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3605. [PMID: 35481668 DOI: 10.1002/cnm.3605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Accepted: 04/14/2022] [Indexed: 06/14/2023]
Abstract
It is shown that certain locations in the arterial tree, such as coronary and cerebral arteries, are more prevalent to plaque formation. Endothelial activation and consequent plaque development are attributed to local hemodynamic parameters such as wall shear stress (WSS), oscillatory shear index (OSI), relative residence time (RRT), and stress phase angle. After a certain level of plaque progression, these hemodynamic parameters are disturbed before and after the plaque. In the current study, it is hypothesized that the vicinity of a primary lesion is susceptible for further degeneration and second plaque formation. A fluid-solid interaction (FSI) model of the coronary artery with different levels of asymmetric constriction, is simulated and the trend of hemodynamic parameters were studied in both of the plaque side (PS) and the opposite wall (facing the plaque [PF]). Also, a novel factor is introduced that can identify the high-risk regions associated with WSS oscillations to negative values. Our results indicate that when more than half of the artery is constricted, the downstream of the plaque is highly exposed to endothelial pathogenesis the PS, such that negative WSS, and as well, critical values of OSI and RRT, that is, -1.2 Pa, 0.42 and 6.5 s, respectively arise in this region. PS endothelial cells in this region exposed to the highest risk of atherosclerosis based on the proposed index (3 out of 3). As well, three cases of angiographic images are provided that confirms existence of secondary lesion close to the primary one as predicted by our computational simulations.
Collapse
Affiliation(s)
- Ahmad Nooraeen
- Tissue Mechanics Lab, Faculty of Biomedical Engineering, Sahand University of Technology, Tabriz, Iran
| | - Farzan Ghalichi
- Faculty of Biomedical Engineering, Sahand University of Technology, Tabriz, Iran
| | - Hadi Taghizadeh
- Tissue Mechanics Lab, Faculty of Biomedical Engineering, Sahand University of Technology, Tabriz, Iran
| | - Robert Guidoin
- Department of Surgery, Université Laval and Division of Regenerative Medicine, CHU de Québec Research Centre, Quebec, Canada
| |
Collapse
|
13
|
Loukas VS, Karanasiou GS, Pleouras D, Katsouras CC, Tachos NS, Sakellarios AI, Semertzioglou A, Michalis LK, Fotiadis DI. Investigation of crimping effects on the stent deployment through in silico modeling. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:621-624. [PMID: 36085907 DOI: 10.1109/embc48229.2022.9871622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Atherosclerosis is one of the most mortal diseases that affects the arterial vessels, due to accumulation of plaque, altering the hemodynamic environment of the artery by preventing the sufficient delivery of blood to other organs. Stents are expandable tubular wires, used as a treatment option. In silico studies have been extensively exploited towards examining the performance of such devices by employing Finite Element Modeling. This study models the crimping stage during stent implantation to examine the effect of inclusion of pre-stress state of the stent. The results show that modeling of the crimping stress state of the stent prior to the deployment results in under-expansion of the stent, due to the indirect inclusion of strain-induced hardening effects. As a result, it is evident that the compressive stent stress configuration is important to be considered in the computational modeling approaches of stent deployment.
Collapse
|
14
|
Silva H, Tassone C, Ross EG, Lee JT, Zhou W, Nelson D. Collagen Fibril Orientation in Tissue Specimens From Atherosclerotic Plaque Explored Using Small Angle X-Ray Scattering. J Biomech Eng 2022; 144:024505. [PMID: 34529040 PMCID: PMC10782870 DOI: 10.1115/1.4052432] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Revised: 08/22/2021] [Indexed: 01/12/2023]
Abstract
Atherosclerotic plaques can gradually develop in certain arteries. Disruption of fibrous tissue in plaques can result in plaque rupture and thromboembolism, leading to heart attacks and strokes. Collagen fibrils are important tissue building blocks and tissue strength depends on how fibrils are oriented. Fibril orientation in plaque tissue may potentially influence vulnerability to disruption. While X-ray scattering has previously been used to characterize fibril orientations in soft tissues and bones, it has never been used for characterization of human atherosclerotic plaque tissue. This study served to explore fibril orientation in specimens from human plaques using small angle X-ray scattering (SAXS). Plaque tissue was extracted from human femoral and carotid arteries, and each tissue specimen contained a region of calcified material. Three-dimensional (3D) collagen fibril orientation was determined along scan lines that started away from and then extended toward a given calcification. Fibrils were found to be oriented mainly in the circumferential direction of the plaque tissue at the majority of locations away from calcifications. However, in a number of cases, the dominant fibril direction differed near a calcification, changing from circumferential to longitudinal or thickness (radial) directions. Further study is needed to elucidate how these fibril orientations may influence plaque tissue stress-strain behavior and vulnerability to rupture.
Collapse
Affiliation(s)
- Herbert Silva
- NASA, 2101 NASA Parkway Building 13 R 208, Houston, TX 77058
| | - Christopher Tassone
- Stanford Synchrotron Radiation Lightsource, 2575 Sand Hill Road, Menlo Park, CA 94025
| | - Elsie Gyang Ross
- Division of Vascular Surgery, Stanford Medical Center, 300 Pasteur Drive, Stanford, CA 94305
| | - Jason T. Lee
- Division of Vascular Surgery, Stanford Medical Center, 300 Pasteur Drive, Stanford, CA 94305
| | - Wei Zhou
- Vascular Surgery Division, College of Medicine, University of Arizona, Tucson, AZ 85724
| | - Drew Nelson
- Mechanical Engineering Department, Stanford University, Stanford, CA 94305
| |
Collapse
|
15
|
An inverse method for mechanical characterization of heterogeneous diseased arteries using intravascular imaging. Sci Rep 2021; 11:22540. [PMID: 34795350 PMCID: PMC8602310 DOI: 10.1038/s41598-021-01874-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2021] [Accepted: 10/27/2021] [Indexed: 11/08/2022] Open
Abstract
The increasing prevalence of finite element (FE) simulations in the study of atherosclerosis has spawned numerous inverse FE methods for the mechanical characterization of diseased tissue in vivo. Current approaches are however limited to either homogenized or simplified material representations. This paper presents a novel method to account for tissue heterogeneity and material nonlinearity in the recovery of constitutive behavior using imaging data acquired at differing intravascular pressures by incorporating interfaces between various intra-plaque tissue types into the objective function definition. Method verification was performed in silico by recovering assigned material parameters from a pair of vessel geometries: one derived from coronary optical coherence tomography (OCT); one generated from in silico-based simulation. In repeated tests, the method consistently recovered 4 linear elastic (0.1 ± 0.1% error) and 8 nonlinear hyperelastic (3.3 ± 3.0% error) material parameters. Method robustness was also highlighted in noise sensitivity analysis, where linear elastic parameters were recovered with average errors of 1.3 ± 1.6% and 8.3 ± 10.5%, at 5% and 20% noise, respectively. Reproducibility was substantiated through the recovery of 9 material parameters in two more models, with mean errors of 3.0 ± 4.7%. The results highlight the potential of this new approach, enabling high-fidelity material parameter recovery for use in complex cardiovascular computational studies.
Collapse
|
16
|
Loukas VS, Karanasiou GS, Pleouras D, Kyriakidis S, Sakellarios AI, Semertzioglou A, Michalis LK, Fotiadis DI. Investigation of Drug Eluting Stents performance in human atherosclerotic artery through in silico modeling. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:5433-5436. [PMID: 34892355 DOI: 10.1109/embc46164.2021.9629895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Atherosclerosis is a chronic inflammatory disease associated with heart attack and stroke. It causes the growth of atherosclerotic plaques inside the arterial vessels, which in turn results to the reduction of the blood flow to the different organs. Drug-Eluting Stents (DES) are mesh-like wires, carrying pharmaceutical coating, designed to dilate and support the arterial vessel, restore blood flow and through the controlled local drug delivery inhibit neo-intimal thickening. In silico modeling is an efficient method of accurately predicting and assessing the performance of the stenting procedure. The present in silico study investigates the performance of two different stents (Bare Metal Stent, Drug-Eluting Stent) in a patient-specific coronary artery and assesses the effect of stent coating, considering that the same procedural approach is followed by the interventional cardiologist. The results demonstrate that even if small differences are obtained in the two models, the incorporation of the stent coatings (in DES) does not significantly affect the outcomes of the stent deployment, the stresses and strains in the scaffold and the arterial tissue. Nevertheless, it is suggested that regarding the DES expansion, higher pressure should be applied at the inner surface of the stent.
Collapse
|
17
|
Noble C, Carlson K, Neumann E, Lewis B, Dragomir-Daescu D, Lerman A, Erdemir A, Young M. Finite element analysis in clinical patients with atherosclerosis. J Mech Behav Biomed Mater 2021; 125:104927. [PMID: 34740008 PMCID: PMC8665142 DOI: 10.1016/j.jmbbm.2021.104927] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 12/31/2020] [Accepted: 10/25/2021] [Indexed: 01/03/2023]
Abstract
Endovascular plaque composition is strongly related to stent strut stress and is responsible for strut fatigue, stent failure, and possible in-stent restenosis. To evaluate the effect of plaque on artery wall resistance to expansion we performed in silico analysis of atherosclerotic vessels. We generated finite element models from in vivo intravascular ultrasound virtual histology images to determine local artery surface stiffness and determined which plaque structures have the greatest influence. We validated the predictive capacity of our modeling approach by testing an atherosclerotic peripheral artery ex vivo with pressure-inflation testing at physiological pressures ranging from 10 to 200 mmHg. For this purpose, the in silico deformation of the arterial wall was compared to that observed ex vivo. We found that calcification had a positive effect on surface stiffness with fibrous plaque and necrotic core having negative effects. Additionally, larger plaque structures demonstrated significantly higher average surface stiffness and calcification located nearer the lumen was also shown to increase surface stiffness. Therefore, more developed plaques will have greater resistance to expansion and higher stent strut stress, with calcification located near the lumen further increasing stress in localized areas. Thus, it may be expected that such plaque structures may increase the likelihood of localized stent strut fracture.
Collapse
Affiliation(s)
- Christopher Noble
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Kent Carlson
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Erica Neumann
- Department of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Bradley Lewis
- Division of Biomedical Statistics and Informatics, Mayo Clinic, Rochester, MN, USA
| | - Dan Dragomir-Daescu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Amir Lerman
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Ahmet Erdemir
- Department of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Melissa Young
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
18
|
Kadry K, Olender ML, Marlevi D, Edelman ER, Nezami FR. A platform for high-fidelity patient-specific structural modelling of atherosclerotic arteries: from intravascular imaging to three-dimensional stress distributions. J R Soc Interface 2021; 18:20210436. [PMID: 34583562 DOI: 10.1098/rsif.2021.0436] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
The pathophysiology of atherosclerotic lesions, including plaque rupture triggered by mechanical failure of the vessel wall, depends directly on the plaque morphology-modulated mechanical response. The complex interplay between lesion morphology and structural behaviour can be studied with high-fidelity computational modelling. However, construction of three-dimensional (3D) and heterogeneous models is challenging, with most previous work focusing on two-dimensional geometries or on single-material lesion compositions. Addressing these limitations, we here present a semi-automatic computational platform, leveraging clinical optical coherence tomography images to effectively reconstruct a 3D patient-specific multi-material model of atherosclerotic plaques, for which the mechanical response is obtained by structural finite-element simulations. To demonstrate the importance of including multi-material plaque components when recovering the mechanical response, a computational case study was conducted in which systematic variation of the intraplaque lipid and calcium was performed. The study demonstrated that the inclusion of various tissue components greatly affected the lesion mechanical response, illustrating the importance of multi-material formulations. This platform accordingly provides a viable foundation for studying how plaque micro-morphology affects plaque mechanical response, allowing for patient-specific assessments and extension into clinically relevant patient cohorts.
Collapse
Affiliation(s)
- Karim Kadry
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA.,Laboratory of Hemodynamics and Cardiovascular Technology, Swiss Federal Institute of Technology, MED 3.2922, 1015 Lausanne, Switzerland
| | - Max L Olender
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - David Marlevi
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Elazer R Edelman
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA.,Cardiovascular Division, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Farhad R Nezami
- Thoracic and Cardiac Surgery Division, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
19
|
Klyshnikov KU, Rezvova MA, Ovcharenko EA, Glushkova TV, Batranin AV, Nyshtaev DV, Zakharov YN, Borisov VG, Kudryavtseva YA, Barbarash LS. An Experimental Study of the Reinforcing Element of a Vascular Prosthesis Fabricated Using the Internal Thoracic Artery of Large Cattle. Biophysics (Nagoya-shi) 2021. [DOI: 10.1134/s0006350921040096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
20
|
Niemann A, Voß S, Tulamo R, Weigand S, Preim B, Berg P, Saalfeld S. Complex wall modeling for hemodynamic simulations of intracranial aneurysms based on histologic images. Int J Comput Assist Radiol Surg 2021; 16:597-607. [PMID: 33715047 PMCID: PMC8052238 DOI: 10.1007/s11548-021-02334-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Accepted: 02/25/2021] [Indexed: 12/04/2022]
Abstract
Purpose For the evaluation and rupture risk assessment of intracranial aneurysms, clinical, morphological and hemodynamic parameters are analyzed. The reliability of intracranial hemodynamic simulations strongly depends on the underlying models. Due to the missing information about the intracranial vessel wall, the patient-specific wall thickness is often neglected as well as the specific physiological and pathological properties of the vessel wall. Methods In this work, we present a model for structural simulations with patient-specific wall thickness including different tissue types based on postmortem histologic image data. Images of histologic 2D slices from intracranial aneurysms were manually segmented in nine tissue classes. After virtual inflation, they were combined into 3D models. This approach yields multiple 3D models of the inner and outer wall and different tissue parts as a prerequisite for subsequent simulations. Result We presented a pipeline to generate 3D models of aneurysms with respect to the different tissue textures occurring in the wall. First experiments show that including the variance of the tissue in the structural simulation affect the simulation result. Especially at the interfaces between neighboring tissue classes, the larger influence of stiffer components on the stability equilibrium became obvious. Conclusion The presented approach enables the creation of a geometric model with differentiated wall tissue. This information can be used for different applications, like hemodynamic simulations, to increase the modeling accuracy.
Collapse
Affiliation(s)
- Annika Niemann
- Faculty of Computer Science, Otto-von-Guericke University Magdeburg, Universitätsplatz 2, D-39106, Magdeburg, Germany.
| | - Samuel Voß
- Laboratory of Fluid Dynamics and Technical Flows, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Riikka Tulamo
- Department of Vascular Surgery, and Neurosurgery Research Group, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - Simon Weigand
- Department of General, Visceral and Transplantation Surgery, Hospital of the University of Munich, Campus Grosshadern, Munich, Germany
| | - Bernhard Preim
- Faculty of Computer Science, Otto-von-Guericke University Magdeburg, Universitätsplatz 2, D-39106, Magdeburg, Germany
| | - Philipp Berg
- Laboratory of Fluid Dynamics and Technical Flows, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.,Forschungscampus STIMULATE, Magdeburg, Germany
| | - Sylvia Saalfeld
- Faculty of Computer Science, Otto-von-Guericke University Magdeburg, Universitätsplatz 2, D-39106, Magdeburg, Germany.,Forschungscampus STIMULATE, Magdeburg, Germany
| |
Collapse
|
21
|
Jayendiran R, Nour B, Ruimi A. Performance of a Nitinol Honeycomb Stent for the Management of Atherosclerotic Aortic Plaque: Crimping, Sealing, and Fluid–Structure Interaction Analysis. JOURNAL OF APPLIED MECHANICS 2021; 88. [DOI: 10.1115/1.4049139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2025]
Abstract
Abstract
We present the results of a computational study to investigate the performance of a nitinol honeycomb stent used in the management of an aortic atherosclerotic plaque with 70% stenosis. Such is considered severe and is associated with a higher risk of cardiovascular death. Traditionally, plaque size, composition, shape, and location are thought as important factors in determining the potential for the plaque to rupture (aka plaque vulnerability). The study looks at two plaque shapes and two plaque compositions. The stent used in the simulations is our own design. It compresses and expands due to nitinol’s superelastic property. The human aorta is represented by the Gasser–Ogden–Holzapfel (GOH) model, a sophisticated hyperelastic model which accounts for the dispersion of fibers present in the tissues. We proceed to investigate how the stent–aorta–plaque structure behaves under a physiological blood flow. Results indicate that the stent as designed can sustain realistic blood flow conditions and that hypocellular plaques are more prone to rupture, in agreement with results published in the literature. It also shows that neither plaque composition nor shape affect the wall shear stress (WSS). This study can be useful to surgeons to identify regions of stenotic aorta subjected to high stress, to select the appropriate stent diameter for aortae with plaques with various compositions and plaque shapes, and to decide on the optimal site for stent implantation.
Collapse
Affiliation(s)
- Raja Jayendiran
- Mechanical Engineering Program, Texas A&M University at Qatar, Doha, Qatar
| | - Bakr Nour
- Division of General Surgery, Weill Cornell Medicine-Qatar, Doha, Qatar
| | - Annie Ruimi
- Mechanical Engineering Program, Texas A&M University at Qatar, Doha, Qatar
| |
Collapse
|
22
|
Noble C, Carlson KD, Neumann E, Doherty S, Dragomir-Daescu D, Lerman A, Erdemir A, Young M. Evaluation of the role of peripheral artery plaque geometry and composition on stent performance. J Mech Behav Biomed Mater 2021; 116:104346. [PMID: 33529996 DOI: 10.1016/j.jmbbm.2021.104346] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 01/05/2021] [Accepted: 01/17/2021] [Indexed: 11/27/2022]
Abstract
Peripheral stent fracture is a major precursor to restenosis of femoral artery atherosclerosis that has been treated with stent implantation. In this work, we validate a workflow for performing in silico stenting on a patient specific peripheral artery with heterogeneous plaque structure. Six human cadaveric femoral arteries were imaged ex vivo using intravascular ultrasound virtual histology (IVUS-VH) to obtain baseline vessel geometry and plaque structure. The vessels were then stented and the imaging repeated to obtain the stented vessel lumen area. Finite element (FE) models were then constructed using the IVUS-VH images, where the material property constants for each finite element were calculated using the proportions of each plaque component in the element, as identified by the IVUS-VH images. A virtual stent was deployed in each FE model, and the model lumen area was calculated and compared to the experimental lumen area to validate the modeling approach. The model was then used to compare stent performance for heterogeneous and homogeneous artery models, to determine whether plaque geometry or composition had added effects on stent performance. We found that the simulated lumen areas were similar to the corresponding experimental values, despite using generic material constants. Additionally, the heterogeneous and homogeneous lumen areas were also similar, implying that plaque geometry is a stronger predictor of stent expansion performance than plaque composition. Comparing stent stress and strain for heterogeneous and homogeneous models, it was found that stress from these two models had a strong linear correlation, while the strain correlation was weaker but still present. This implies that stent performance may be predicted with a simple homogeneous material models accounting for overall geometry of the plaque, providing that stent fatigue is calculated using stress criteria.
Collapse
Affiliation(s)
- Christopher Noble
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Kent D Carlson
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Erica Neumann
- Department of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Sean Doherty
- Department of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Dan Dragomir-Daescu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Amir Lerman
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Ahmet Erdemir
- Department of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Melissa Young
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
23
|
Lashkarinia SS, Coban G, Kose B, Salihoglu E, Pekkan K. Computational modeling of vascular growth in patient-specific pulmonary arterial patch reconstructions. J Biomech 2021; 117:110274. [PMID: 33540217 DOI: 10.1016/j.jbiomech.2021.110274] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 01/09/2021] [Accepted: 01/16/2021] [Indexed: 11/15/2022]
Abstract
Recent progress in vascular growth mechanics has involved the use of computational algorithms to address clinical problems with the use of three-dimensional patient specific geometries. The objective of this study is to establish a predictive computational model for the volumetric growth of pulmonary arterial (PA) tissue following complex cardiovascular patch reconstructive surgeries for congenital heart disease patients. For the first time in the literature, the growth mechanics and performance of artificial cardiovascular patches in contact with the growing PA tissue domain is established. An elastic-growing material model was developed in the open source FEBio software suite to first examine the surgical patch reconstruction process for an idealized main PA anatomy as a benchmark model and then for the patient-specific PA of a newborn. Following patch reconstruction, high levels of stress and strain are compensated by growth on the arterial tissue. As this growth progresses, the arterial tissue is predicted to stiffen to limit elastic deformations. We simulated this arterial growth up to the age of 18 years, when somatic growth plateaus. Our research findings show that the non-growing patch material remains in a low strain state throughout the simulation timeline, while experiencing high stress hot-spots. Arterial tissue growth along the surgical stitch lines is triggered mainly due to PA geometry and blood pressure, rather than due to material property differences in the artificial and native tissue. Thus, non-uniform growth patterns are observed along the arterial tissue proximal to the sutured boundaries. This computational approach is effective for the pre-surgical planning of complex patch surgeries to quantify the unbalanced growth of native arteries and artificial non-growing materials to develop optimal patch biomechanics for improved postoperative outcomes.
Collapse
Affiliation(s)
| | - Gursan Coban
- Mechanical Engineering, Istinye University, Turkey
| | - Banu Kose
- Biomedical Engineering, Medipol University, Turkey
| | - Ece Salihoglu
- School of Medicine, Istanbul Bilim University, Turkey
| | | |
Collapse
|