1
|
Villarini NA, Robins N, Ou Y. Fabrication and Optimization of a Molecularly Imprinted Carbon Fiber Microelectrode for Selective Detection of Met-enkephalin Using Fast-Scan Cyclic Voltammetry. ACS APPLIED MATERIALS & INTERFACES 2024; 16:29728-29736. [PMID: 38804619 DOI: 10.1021/acsami.4c03093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
Methionine-enkephalin (Met-Enk) is an endogenous opioid peptide that is involved in various physiological processes including memory. A technological gap in the understanding of Met-Enk's role in memory is the lack of rapid measurement tools to selectively quantify Met-Enk concentrations in situ. Here, we integrate molecularly imprinted polymers (MIPs) with carbon fiber microelectrodes (CFMs) to selectively detect Met-Enk by using fast-scan cyclic voltammetry (FSCV). We report two MIP conditions that yield 2-fold and 5-fold higher selectivity toward Met-Enk than the tyrosine-containing hexapeptide fragment angiotensin II (3-8). We demonstrate that MIP technology can be combined with FSCV at CFMs to create rapid and selective sensors for Met-Enk. This technology is a promising platform for creating selective sensors for other peptides and biomarkers.
Collapse
Affiliation(s)
- Nicole A Villarini
- Department of Chemistry, University of Vermont, 82 University Place, Burlington, Vermont 05405, United States
| | - Nathan Robins
- Department of Chemistry, University of Vermont, 82 University Place, Burlington, Vermont 05405, United States
| | - Yangguang Ou
- Department of Chemistry, University of Vermont, 82 University Place, Burlington, Vermont 05405, United States
| |
Collapse
|
2
|
Kaur H, Siwal SS, Saini RV, Singh N, Thakur VK. Significance of an Electrochemical Sensor and Nanocomposites: Toward the Electrocatalytic Detection of Neurotransmitters and Their Importance within the Physiological System. ACS NANOSCIENCE AU 2022; 3:1-27. [PMID: 37101467 PMCID: PMC10125382 DOI: 10.1021/acsnanoscienceau.2c00039] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/17/2022] [Accepted: 10/17/2022] [Indexed: 11/07/2022]
Abstract
A prominent neurotransmitter (NT), dopamine (DA), is a chemical messenger that transmits signals between one neuron to the next to pass on a signal to and from the central nervous system (CNS). The imbalanced concentration of DA may cause numerous neurological sicknesses and syndromes, for example, Parkinson's disease (PD) and schizophrenia. There are many types of NTs in the brain, including epinephrine, norepinephrine (NE), serotonin, and glutamate. Electrochemical sensors have offered a creative direction to biomedical analysis and testing. Researches are in progress to improve the performance of sensors and develop new protocols for sensor design. This review article focuses on the area of sensor growth to discover the applicability of polymers and metallic particles and composite materials as tools in electrochemical sensor surface incorporation. Electrochemical sensors have attracted the attention of researchers as they possess high sensitivity, quick reaction rate, good controllability, and instantaneous detection. Efficient complex materials provide considerable benefits for biological detection as they have exclusive chemical and physical properties. Due to distinctive electrocatalytic characteristics, metallic nanoparticles add fascinating traits to materials that depend on the material's morphology and size. Herein, we have collected much information on NTs and their importance within the physiological system. Furthermore, the electrochemical sensors and corresponding techniques (such as voltammetric, amperometry, impedance, and chronoamperometry) and the different types of electrodes' roles in the analysis of NTs are discussed. Furthermore, other methods for detecting NTs include optical and microdialysis methods. Finally, we show the advantages and disadvantages of different techniques and conclude remarks with future perspectives.
Collapse
Affiliation(s)
- Harjot Kaur
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Samarjeet Singh Siwal
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Reena V. Saini
- Department of Biotechnology, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Nirankar Singh
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Vijay Kumar Thakur
- Biorefining and Advanced Materials Research Center, Scotland’s Rural College (SRUC), Kings Buildings, Edinburgh EH9 3JG, United Kingdom
- School of Engineering, University of Petroleum & Energy Studies (UPES), Dehradun, Uttarakhand 248007, India
- Centre for Research & Development, Chandigarh University, Mohali, Punjab 140413, India
| |
Collapse
|
3
|
Mukunda DC, Rodrigues J, Joshi VK, Raghushaker CR, Mahato KK. A comprehensive review on LED-induced fluorescence in diagnostic pathology. Biosens Bioelectron 2022; 209:114230. [PMID: 35421670 DOI: 10.1016/j.bios.2022.114230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 03/19/2022] [Accepted: 03/25/2022] [Indexed: 11/02/2022]
Abstract
Sensitivity, specificity, mobility, and affordability are important criteria to consider for developing diagnostic instruments in common use. Fluorescence spectroscopy has been demonstrating substantial potential in the clinical diagnosis of diseases and evaluating the underlying causes of pathogenesis. A higher degree of device integration with appropriate sensitivity and reasonable cost would further boost the value of the fluorescence techniques in clinical diagnosis and aid in the reduction of healthcare expenses, which is a key economic concern in emerging markets. Light-emitting diodes (LEDs), which are inexpensive and smaller are attractive alternatives to conventional excitation sources in fluorescence spectroscopy, are gaining a lot of momentum in the development of affordable, compact analytical instruments of clinical relevance. The commercial availability of a broad range of LED wavelengths (255-4600 nm) has opened up new avenues for targeting a wide range of clinically significant molecules (both endogenous and exogenous), thereby diagnosing a range of clinical illnesses. As a result, we have specifically examined the uses of LED-induced fluorescence (LED-IF) in preclinical and clinical evaluations of pathological conditions, considering the present advancements in the field.
Collapse
Affiliation(s)
| | - Jackson Rodrigues
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka-576104, India
| | - Vijay Kumar Joshi
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka-576104, India
| | - Chandavalli Ramappa Raghushaker
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka-576104, India
| | - Krishna Kishore Mahato
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka-576104, India.
| |
Collapse
|
4
|
Twenty years of amino acid determination using capillary electrophoresis: A review. Anal Chim Acta 2021; 1174:338233. [DOI: 10.1016/j.aca.2021.338233] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 01/14/2021] [Accepted: 01/16/2021] [Indexed: 12/28/2022]
|
5
|
Boulanger-Bertolus J, Parrot S, Doyère V, Mouly AM. Dorsal striatum and the temporal expectancy of an aversive event in Pavlovian odor fear learning. Neurobiol Learn Mem 2021; 182:107446. [PMID: 33915299 DOI: 10.1016/j.nlm.2021.107446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 04/07/2021] [Accepted: 04/22/2021] [Indexed: 11/28/2022]
Abstract
Interval timing, the ability to encode and retrieve the memory of intervals from seconds to minutes, guides fundamental animal behaviors across the phylogenetic tree. In Pavlovian fear conditioning, an initially neutral stimulus (conditioned stimulus, CS) predicts the arrival of an aversive unconditioned stimulus (US, generally a mild foot-shock) at a fixed time interval. Although some studies showed that temporal relations between CS and US events are learned from the outset of conditioning, the question of the memory of time and its underlying neural network in fear conditioning is still poorly understood. The aim of the present study was to investigate the role of the dorsal striatum in timing intervals in odor fear conditioning in male rats. To assess the animal's interval timing ability in this paradigm, we used the respiratory frequency. This enabled us to detect the emergence of temporal patterns related to the odor-shock time interval from the early stage of learning, confirming that rats are able to encode the odor-shock time interval after few training trials. We carried out reversible inactivation of the dorsal striatum before the acquisition session and before a shift in the learned time interval, and measured the effects of this treatment on the temporal pattern of the respiratory rate. In addition, using intracerebral microdialysis, we monitored extracellular dopamine level in the dorsal striatum throughout odor-shock conditioning and in response to a shift of the odor-shock time interval. Contrary to our initial predictions based on the existing literature on interval timing, we found evidence suggesting that transient inactivation of the dorsal striatum may favor a more precocious buildup of the respiratory frequency's temporal pattern during the odor-shock interval in a manner that reflected the duration of the interval. Our data further suggest that the conditioning and the learning of a novel time interval were associated with a decrease in dopamine level in the dorsal striatum, but not in the nucleus accumbens. These findings prompt a reassessment of the role of the striatum and striatal dopamine in interval timing, at least when considering Pavlovian aversive conditioning.
Collapse
Affiliation(s)
- Julie Boulanger-Bertolus
- Lyon Neuroscience Research Center, INSERM U1028, CNRS UMR 5292, University Lyon 1, Lyon 69366, France.
| | - Sandrine Parrot
- Université Paris-Saclay, CNRS, Institut des Neurosciences Paris-Saclay, 91190 Gif-sur-Yvette, France
| | - Valérie Doyère
- Université Paris-Saclay, CNRS, Institut des Neurosciences Paris-Saclay, 91190 Gif-sur-Yvette, France; NYU Child Study Center Department of Child and Adolescent Psychiatry, New York University Langone School of Medicine, NY, USA
| | - Anne-Marie Mouly
- Lyon Neuroscience Research Center, INSERM U1028, CNRS UMR 5292, University Lyon 1, Lyon 69366, France
| |
Collapse
|
6
|
Celá A, Glatz Z. Homocyclic
o
‐dicarboxaldehydes: Derivatization reagents for sensitive analysis of amino acids and related compounds by capillary and microchip electrophoresis. Electrophoresis 2020; 41:1851-1869. [DOI: 10.1002/elps.202000041] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 05/27/2020] [Accepted: 06/07/2020] [Indexed: 01/01/2023]
Affiliation(s)
- Andrea Celá
- Department of Biochemistry, Faculty of Science Masaryk University Brno Czech Republic
| | - Zdeněk Glatz
- Department of Biochemistry, Faculty of Science Masaryk University Brno Czech Republic
| |
Collapse
|
7
|
Gupta P, Tsai K, Ruhunage CK, Gupta VK, Rahm CE, Jiang D, Alvarez NT. True Picomolar Neurotransmitter Sensor Based on Open-Ended Carbon Nanotubes. Anal Chem 2020; 92:8536-8545. [PMID: 32406234 DOI: 10.1021/acs.analchem.0c01363] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Neurotransmitters are important chemicals in human physiological systems for initiating neuronal signaling pathways and in various critical health illnesses. However, concentration of neurotransmitters in the human body is very low (nM or pM level) and it is extremely difficult to detect the fluctuation of their concentrations in patients using existing electrochemical biosensors. In this work, we report the performance of highly densified carbon nanotubes fiber (HD-CNTf) cross-sections called rods (diameter ∼ 69 μm, and length ∼ 40 μm) as an ultrasensitive platform for detection of common neurotransmitters. HD-CNTf rods microelectrodes have open-ended CNTs exposed at the interface with electrolytes and cells and display a low impedance value, i.e., 1050 Ω. Their fabrication starts with dry spun CNT fibers that are encapsulated in an insulating polymer to preserve their structure and alignment. Arrays of HD-CNTf rods microelectrodes were applied to detect neurotransmitters, i.e., dopamine (DA), serotonin (5-HT), epinephrine (Epn), and norepinephrine (Norepn), using square wave voltammetry (SWV) and cyclic voltammetry (CV). They demonstrate good linearity in a broad linear range (1 nM to 100 μM) with an excellent limit of detection, i.e., 32 pM, 31 pM, 64 pM, and 9 pM for DA, 5-HT, Epn, and Norepn, respectively. To demonstrate practical application of HD-CNTf rod arrays, detection of DA in human biological fluids and real time monitoring of DA release from living pheochromocytoma (PC12) cells were performed.
Collapse
Affiliation(s)
- Pankaj Gupta
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Kyrus Tsai
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Chethani K Ruhunage
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Vandna K Gupta
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Connor E Rahm
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Dehua Jiang
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Noe T Alvarez
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| |
Collapse
|
8
|
Feng S, Shirani E, Inglis DW. Droplets for Sampling and Transport of Chemical Signals in Biosensing: A Review. BIOSENSORS 2019; 9:E80. [PMID: 31226857 PMCID: PMC6627903 DOI: 10.3390/bios9020080] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 06/14/2019] [Accepted: 06/17/2019] [Indexed: 12/14/2022]
Abstract
The chemical, temporal, and spatial resolution of chemical signals that are sampled and transported with continuous flow is limited because of Taylor dispersion. Droplets have been used to solve this problem by digitizing chemical signals into discrete segments that can be transported for a long distance or a long time without loss of chemical, temporal or spatial precision. In this review, we describe Taylor dispersion, sampling theory, and Laplace pressure, and give examples of sampling probes that have used droplets to sample or/and transport fluid from a continuous medium, such as cell culture or nerve tissue, for external analysis. The examples are categorized, as follows: (1) Aqueous-phase sampling with downstream droplet formation; (2) preformed droplets for sampling; and (3) droplets formed near the analyte source. Finally, strategies for downstream sample recovery for conventional analysis are described.
Collapse
Affiliation(s)
- Shilun Feng
- School of Engineering, Macquarie University, Sydney, NSW 2109, Australia.
- ARC Centre of Excellence for Nanoscale BioPhotonics (CNBP), Macquarie University, Sydney, NSW 2109, Australia.
| | - Elham Shirani
- School of Engineering, Macquarie University, Sydney, NSW 2109, Australia.
| | - David W Inglis
- School of Engineering, Macquarie University, Sydney, NSW 2109, Australia.
- ARC Centre of Excellence for Nanoscale BioPhotonics (CNBP), Macquarie University, Sydney, NSW 2109, Australia.
| |
Collapse
|
9
|
Clinical implications and electrochemical biosensing of monoamine neurotransmitters in body fluids, in vitro, in vivo, and ex vivo models. Biosens Bioelectron 2018; 121:137-152. [DOI: 10.1016/j.bios.2018.09.002] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 08/25/2018] [Accepted: 09/01/2018] [Indexed: 12/13/2022]
|
10
|
Ngernsutivorakul T, Steyer DJ, Valenta AC, Kennedy RT. In Vivo Chemical Monitoring at High Spatiotemporal Resolution Using Microfabricated Sampling Probes and Droplet-Based Microfluidics Coupled to Mass Spectrometry. Anal Chem 2018; 90:10943-10950. [PMID: 30107117 DOI: 10.1021/acs.analchem.8b02468] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
An essential approach for in vivo chemical monitoring is to use sampling probes coupled with analytical methods; however, this method traditionally has limited spatial and temporal resolution. To address this problem, we developed an analytical system that combines microfabricated push-pull sampling probes with droplet-based microfluidics. The microfabricated probe provides spatial resolution approximately 1000-fold better than that of common microdialysis probes. Microfabrication also facilitated integration of an extra channel into the probe for microinjection. We created microfluidic devices and interfaces that allowed manipulation of nanoliter droplet samples collected from the microfabricated probe at intervals of a few seconds. Use of droplet-based microfluidics prevented broadening of collected zones, yielding 6 s temporal resolution at 100 nL/min perfusion rates. Resulting droplets were analyzed by direct infusion nanoelectrospray ionization (nESI) mass spectrometry for simultaneous determination of glutamine, glutamate, γ-aminobutyric acid, and acetylcholine. Use of low infusion rates that enabled nESI (50 nL/min) was critical to allowing detection in the complex samples. Addition of 13C-labeled internal standards to the droplet samples was used for improved quantification. Utility of the overall system was demonstrated by monitoring dynamic chemical changes evoked by microinjection of high potassium concentrations into the brain of live rats. The results showed stimulated neurochemical release with rise times of 15 s. This work demonstrates the potential of coupling microfabricated sampling probes to droplet-based mass spectrometric assays for studying chemical dynamics in a complex microenvironment at high spatiotemporal resolution.
Collapse
Affiliation(s)
- Thitaphat Ngernsutivorakul
- Department of Chemistry , University of Michigan , 930 N. University Avenue , Ann Arbor , Michigan 48109 , United States
| | - Daniel J Steyer
- Department of Chemistry , University of Michigan , 930 N. University Avenue , Ann Arbor , Michigan 48109 , United States
| | - Alec C Valenta
- Department of Chemistry , University of Michigan , 930 N. University Avenue , Ann Arbor , Michigan 48109 , United States
| | - Robert T Kennedy
- Department of Chemistry , University of Michigan , 930 N. University Avenue , Ann Arbor , Michigan 48109 , United States.,Department of Pharmacology , University of Michigan , 1150 W. Medical Center Drive , Ann Arbor , Michigan 48109 , United States
| |
Collapse
|
11
|
Ngernsutivorakul T, White TS, Kennedy RT. Microfabricated Probes for Studying Brain Chemistry: A Review. Chemphyschem 2018; 19:1128-1142. [PMID: 29405568 PMCID: PMC6996029 DOI: 10.1002/cphc.201701180] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Indexed: 12/13/2022]
Abstract
Probe techniques for monitoring in vivo chemistry (e.g., electrochemical sensors and microdialysis sampling probes) have significantly contributed to a better understanding of neurotransmission in correlation to behaviors and neurological disorders. Microfabrication allows construction of neural probes with high reproducibility, scalability, design flexibility, and multiplexed features. This technology has translated well into fabricating miniaturized neurochemical probes for electrochemical detection and sampling. Microfabricated electrochemical probes provide a better control of spatial resolution with multisite detection on a single compact platform. This development allows the observation of heterogeneity of neurochemical activity precisely within the brain region. Microfabricated sampling probes are starting to emerge that enable chemical measurements at high spatial resolution and potential for reducing tissue damage. Recent advancement in analytical methods also facilitates neurochemical monitoring at high temporal resolution. Furthermore, a positive feature of microfabricated probes is that they can be feasibly built with other sensing and stimulating platforms including optogenetics. Such integrated probes will empower researchers to precisely elucidate brain function and develop novel treatments for neurological disorders.
Collapse
Affiliation(s)
| | - Thomas S. White
- Macromolecular Science and Engineering, University of Michigan, 3003E, NCRC Building 28, 2800 Plymouth Rd., Ann Arbor, MI 48109
| | - Robert T. Kennedy
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI 48109
- Department of Pharmacology, University of Michigan, 1150 W. Medical Center Drive, Ann Arbor, MI 48109
| |
Collapse
|
12
|
Jiao Q, Wang R, Jiang Y, Liu B. Study on the interaction between active components from traditional Chinese medicine and plasma proteins. Chem Cent J 2018; 12:48. [PMID: 29728878 PMCID: PMC5935606 DOI: 10.1186/s13065-018-0417-2] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2017] [Accepted: 04/24/2018] [Indexed: 02/06/2023] Open
Abstract
Traditional Chinese medicine (TCM), as a unique form of natural medicine, has been used in Chinese traditional therapeutic systems over two thousand years. Active components in Chinese herbal medicine are the material basis for the prevention and treatment of diseases. Research on drug-protein binding is one of the important contents in the study of early stage clinical pharmacokinetics of drugs. Plasma protein binding study has far-reaching influence on the pharmacokinetics and pharmacodynamics of drugs and helps to understand the basic rule of drug effects. It is important to study the binding characteristics of the active components in Chinese herbal medicine with plasma proteins for the medical science and modernization of TCM. This review summarizes the common analytical methods which are used to study the active herbal components-protein binding and gives the examples to illustrate their application. Rules and influence factors of the binding between different types of active herbal components and plasma proteins are summarized in the end. Finally, a suggestion on choosing the suitable technique for different types of active herbal components is provided, and the prospect of the drug-protein binding used in the area of TCM research is also discussed.
Collapse
Affiliation(s)
- Qishu Jiao
- School of Chinese Pharmacy, Beijing University of Chinese Medicine, Beijing, 102488, China
| | - Rufeng Wang
- School of Chinese Pharmacy, Beijing University of Chinese Medicine, Beijing, 102488, China
| | - Yanyan Jiang
- School of Chinese Pharmacy, Beijing University of Chinese Medicine, Beijing, 102488, China
| | - Bin Liu
- School of Chinese Pharmacy, Beijing University of Chinese Medicine, Beijing, 102488, China.
| |
Collapse
|
13
|
|
14
|
Ortega-Ibarra J, López-Pérez S, Morales-Villagrán A. An electrochemiluminescent method for glutamate measurement in small microdialysate samples in asphyxiated young rats. LUMINESCENCE 2017; 33:47-53. [PMID: 28718955 DOI: 10.1002/bio.3371] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Revised: 05/16/2017] [Accepted: 05/28/2017] [Indexed: 11/08/2022]
Abstract
Glutamate (Glu) quantification has been performed by a combination of intracerebral microdialysis through which the samples are obtained and analyzed by high performance liquid chromatography (HPLC); its measurement requires a large expenditure of time (15-30 min per sample) and special training. Therefore, an alternative method is presented here, based on the electrochemiluminescence produced by the use of an enzymatic reactor, containing glutamate-oxidase, mixed and incubated with microdialysate from dorsal striatum (DS) and prefrontal cortex (PFC) of young rats asphyxiated during the neonatal period, under a global asphyxia model in order to test this method. Using this approach, we found high extracellular Glu concentration in the DS of asphyxiated animals, but only during K+ stimulation, while in the PFC, only a delay in the rise of Glu after K+ stimulation was observed, without any difference in extracellular Glu content when compared with controls. This new method permitted a fast measurement of Glu in brain dialysate samples, it significantly reduces the cost of the analysis per sample, since only a single device and pump are needed without using columns and high pressure inside the system or complex hardware and software to control pumps, detector, fraction collector or any other peripheral used in HPLC.
Collapse
Affiliation(s)
- Jorge Ortega-Ibarra
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico
| | - Silvia López-Pérez
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico
| | - Alberto Morales-Villagrán
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico
| |
Collapse
|
15
|
Zandy SL, Doherty JM, Wibisono ND, Gonzales RA. High sensitivity HPLC method for analysis of in vivo extracellular GABA using optimized fluorescence parameters for o-phthalaldehyde (OPA)/sulfite derivatives. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1055-1056:1-7. [PMID: 28433865 PMCID: PMC5536952 DOI: 10.1016/j.jchromb.2017.04.003] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Revised: 02/13/2017] [Accepted: 04/01/2017] [Indexed: 11/28/2022]
Abstract
Reversed-phase HPLC with derivatization using o-phthalaldehyde (OPA) and sulfite allows electrochemical detection of γ-aminobutyric acid (GABA) in microdialysis samples. However, OPA/sulfite derivatives have been reported to produce lower fluorescent yield than OPA derivatives using organic thiols as the nucleophile. To overcome this limitation we examined excitation and emission spectra, reaction time, pH, and concentration of reagents in the derivatization solution. Optimal detection parameters were determined as λex=220nm and λem=385nm for maximal fluorescence. The derivatization reaction occurred immediately and the product was stable up to 24 h [corrected]. A pH of 10.4 for the borate buffer used in the derivatization solution was significantly better than lower pH. Increasing the amount of sulfite combined with diluting the derivatization solution in borate buffer resulted in complete separation of the GABA peak from contaminants without any loss in signal. Controlling the temperature of the detector at 15°C significantly improved sensitivity with a detection limit of approximately 1nM. To validate this assay, we performed microdialysis in the dorsal striatum and ventral tegmental area (VTA) of adult Long Evans rats. GABA concentrations in dialysates were determined using external standards and standard additions, in order to further confirm interfering peaks were not present in biological samples. Within the dorsal striatum (n=4), basal GABA concentrations were 12.9±2.2 and 14.5±2.2nM (external and additions, respectively). Respective basal GABA concentrations in the VTA (n=3) were 4.6±1.1 and 5.1±0.6nM. Thus, we have developed a novel, sensitive fluorescence method to determine GABA in microdialysates using HPLC of an OPA/sulfite derivative.
Collapse
Affiliation(s)
- Shannon L Zandy
- Division of Pharmacology and Toxicology, College of Pharmacy, The University of Texas at Austin, Austin, TX, USA
| | - James M Doherty
- Division of Pharmacology and Toxicology, College of Pharmacy, The University of Texas at Austin, Austin, TX, USA
| | - Nathan D Wibisono
- Division of Pharmacology and Toxicology, College of Pharmacy, The University of Texas at Austin, Austin, TX, USA
| | - Rueben A Gonzales
- Division of Pharmacology and Toxicology, College of Pharmacy, The University of Texas at Austin, Austin, TX, USA.
| |
Collapse
|
16
|
Morales-Villagrán A, Pardo-Peña K, Medina-Ceja L, López-Pérez S. A microdialysis and enzymatic reactor sensing procedure for the simultaneous registration of online glutamate measurements at high temporal resolution during epileptiform activity. J Neurochem 2016; 139:886-896. [DOI: 10.1111/jnc.13850] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Revised: 08/10/2016] [Accepted: 09/01/2016] [Indexed: 12/01/2022]
Affiliation(s)
- Alberto Morales-Villagrán
- Laboratory of Neurophysiology and Neurochemistry; Department of Cellular and Molecular Biology; CUCBA; University of Guadalajara; Jalisco México
| | - Kenia Pardo-Peña
- Laboratory of Neurophysiology and Neurochemistry; Department of Cellular and Molecular Biology; CUCBA; University of Guadalajara; Jalisco México
| | - Laura Medina-Ceja
- Laboratory of Neurophysiology and Neurochemistry; Department of Cellular and Molecular Biology; CUCBA; University of Guadalajara; Jalisco México
| | - Silvia López-Pérez
- Laboratory of Neurophysiology and Neurochemistry; Department of Cellular and Molecular Biology; CUCBA; University of Guadalajara; Jalisco México
| |
Collapse
|
17
|
Denoroy L, Parrot S. Analysis of Amino Acids and Related Compounds by Capillary Electrophoresis. SEPARATION AND PURIFICATION REVIEWS 2016. [DOI: 10.1080/15422119.2016.1212378] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
18
|
Stephen TKL, Guillemette KL, Green TK. Analysis of Trinitrophenylated Adenosine and Inosine by Capillary Electrophoresis and γ-Cyclodextrin-Enhanced Fluorescence Detection. Anal Chem 2016; 88:7777-85. [PMID: 27314490 DOI: 10.1021/acs.analchem.6b01796] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Monitoring molecules such as adenosine (Ado) and inosine (Ino) in the central nervous system has enabled the field of neuroscience to correlate molecular concentrations dynamics to neurological function, behavior, and disease. In vivo sampling techniques are commonly used to monitor these dynamics; however, many techniques are limited by the sensitivity and sample volume requirements of currently available detection methods. Here, we present a novel capillary electrophoresis-laser-induced fluorescence detection (CE-LIF) method that analyzes Ado and Ino by derivatization with 2,4,6-trinitrobenzenesulfonic acid to form fluorescent trinitrophenylated complexes of Ado (TNP-Ado) and Ino (TNP-Ino). These complexes exhibit ∼25-fold fluorescence enhancement upon the formation of inclusion complexes with γ-cyclodextrin (γ-CD). Association constants were determined as 4600 M(-1) for Ado and 1000 M(-1) for Ino by CE-LIF. The structure of the TNP-Ado:γ-CD complex was determined by 2D nuclear magnetic resonance (NMR) spectroscopy. Optimal trinitrophenylation reaction conditions and CE-LIF parameters were determined and resulted in the limit of detection of 1.6 μM for Ado and 4 μM for Ino. Ado and Ino were simultaneously quantified in homogenized rat forebrain samples to illustrate application of the technique. Simulated biological samples, desalted by ultrafiltration in the presence γ-CD, were concentrated on-capillary by large-volume sample stacking (LVSS) to achieve detection limits of 32 and 38 nM for TNP-Ado and TNP-Ino, respectively.
Collapse
Affiliation(s)
- Terilyn K L Stephen
- Department of Chemistry and Biochemistry and ‡Institute of Arctic Biology, University of Alaska Fairbanks , Fairbanks, Alaska 99775, United States
| | - Katherine L Guillemette
- Department of Chemistry and Biochemistry and ‡Institute of Arctic Biology, University of Alaska Fairbanks , Fairbanks, Alaska 99775, United States
| | - Thomas K Green
- Department of Chemistry and Biochemistry and ‡Institute of Arctic Biology, University of Alaska Fairbanks , Fairbanks, Alaska 99775, United States
| |
Collapse
|
19
|
Gu H, Varner EL, Groskreutz SR, Michael AC, Weber SG. In Vivo Monitoring of Dopamine by Microdialysis with 1 min Temporal Resolution Using Online Capillary Liquid Chromatography with Electrochemical Detection. Anal Chem 2015; 87:6088-94. [PMID: 25970591 PMCID: PMC4835028 DOI: 10.1021/acs.analchem.5b00633] [Citation(s) in RCA: 83] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Microdialysis is often applied to understanding brain function. Because neurotransmission involves rapid events, increasing the temporal resolution of in vivo measurements is desirable. Here, we demonstrate microdialysis with online capillary liquid chromatography for the analysis of 1 min rat brain dialysate samples at 1 min intervals. Mobile phase optimization involved adjusting the pH, buffer composition, and surfactant concentration to eliminate interferences with the dopamine peak. By analyzing electrically evoked dopamine transients carefully synchronized with the switching of the online LC sample valve, we demonstrate that our system has both 1 min sampling capabilities and bona fide 1 min temporal resolution. Evoked DA transients were confined to single, 1 min brain dialysate samples. After uptake inhibition with nomifensine (20 mg/kg i.p.), responses to electrical stimuli of 1 s duration were detected.
Collapse
Affiliation(s)
- Hui Gu
- #Department of Chemistry, East China Normal University, Shanghai 200062, PRC
| | - Erika L Varner
- †Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Stephen R Groskreutz
- †Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Adrian C Michael
- †Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Stephen G Weber
- †Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| |
Collapse
|
20
|
Cecioni S, Aouadi K, Guiard J, Parrot S, Strazielle N, Blondel S, Ghersi-Egea JF, Chapelle C, Denoroy L, Praly JP. Novel routes to either racemic or enantiopure α-amino-(4-hydroxy-pyrrolidin-3-yl)acetic acid derivatives and biological evaluation of a new promising pharmacological scaffold. Eur J Med Chem 2015; 98:237-49. [PMID: 26043161 DOI: 10.1016/j.ejmech.2015.05.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Revised: 04/23/2015] [Accepted: 05/11/2015] [Indexed: 12/20/2022]
Abstract
Cycloaddition between (+) or (-)-menthone-derived nitrones and N-benzyl-3-pyrroline afforded enantiopure spiro-fused heterocycles. The reaction occurred enantio- and diastereo-selectively on the less hindered side of the nitrone, the 3-pyrroline N-benzyl group being oriented outwards, thus controlling the configurations of three simultaneously created chiral centers. From either (+) or (-)-menthone, both enantiomeric cycloadducts were synthesized in excellent yield. Removing the chiral auxiliary and the N-benzyl group delivered a series of enantiopure 4-hydroxy-3-glycinyl-pyrrolidine derivatives in 3-5 steps and 36 to 81 overall yields. Using two other achiral nitrones, shorter routes to racemic analogues were developed. Two of the synthesized compounds markedly lowered extracellular glutamate level and modestly interacted with cannabinoid type-1 receptors. As these two neuroactive compounds were devoid of in vitro toxicity and did not cross the blood brain interface, they might represent potential pharmacological agents to target peripheral organs.
Collapse
Affiliation(s)
- Samy Cecioni
- CNRS UMR 5246, Université Lyon1, Institut de Chimie et Biochimie Moléculaires et Supramoléculaires (ICBMS), F-69622 Villeurbanne, France
| | - Kaïss Aouadi
- CNRS UMR 5246, Université Lyon1, Institut de Chimie et Biochimie Moléculaires et Supramoléculaires (ICBMS), F-69622 Villeurbanne, France
| | - Julie Guiard
- CNRS UMR 5246, Université Lyon1, Institut de Chimie et Biochimie Moléculaires et Supramoléculaires (ICBMS), F-69622 Villeurbanne, France
| | - Sandrine Parrot
- INSERM U1028, CNRS UMR5292, Université Lyon 1, Lyon Neuroscience Research Center, NeuroDialyTics Unit, Lyon F-69000, France
| | - Nathalie Strazielle
- INSERM U1028, CNRS UMR5292, Université Lyon 1, Lyon Neuroscience Research Center, Blood Brain Interfaces Exploratory Platform BIP, Lyon F-69000, France
| | - Sandrine Blondel
- INSERM U1028, CNRS UMR5292, Université Lyon 1, Lyon Neuroscience Research Center, Blood Brain Interfaces Exploratory Platform BIP, Lyon F-69000, France
| | - Jean-François Ghersi-Egea
- INSERM U1028, CNRS UMR5292, Université Lyon 1, Lyon Neuroscience Research Center, Blood Brain Interfaces Exploratory Platform BIP, Lyon F-69000, France
| | | | - Luc Denoroy
- INSERM U1028, CNRS UMR5292, Université Lyon 1, Lyon Neuroscience Research Center, NeuroDialyTics Unit, Lyon F-69000, France; INSERM U1028, CNRS UMR5292, Université Lyon 1, Lyon Neuroscience Research Center, BioRaN, Lyon F-69000, France.
| | - Jean-Pierre Praly
- CNRS UMR 5246, Université Lyon1, Institut de Chimie et Biochimie Moléculaires et Supramoléculaires (ICBMS), F-69622 Villeurbanne, France
| |
Collapse
|
21
|
Medina-Ceja L, Pardo-Peña K, Morales-Villagrán A, Ortega-Ibarra J, López-Pérez S. Increase in the extracellular glutamate level during seizures and electrical stimulation determined using a high temporal resolution technique. BMC Neurosci 2015; 16:11. [PMID: 25887152 PMCID: PMC4363345 DOI: 10.1186/s12868-015-0147-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2014] [Accepted: 02/20/2015] [Indexed: 12/21/2022] Open
Abstract
Background Glutamate has been measured using different methods to determine its role under normal and pathological conditions. Although microdialysis coupled with HPLC is the preferred method to study glutamate, this technique exhibits poor temporal resolution and is time consuming. The concentration of glutamate in dialysis samples can be measured via glutamate oxidase using the Amplex Red method. Methods A new device has been designed and constructed to rapidly deposit dialysis samples onto a polycarbonate plate at Cartesian coordinates (every five seconds). The samples were added to an enzymatic reaction that generates hydrogen peroxide from glutamate, which was quantified using fluorescence detection. Fluorescence emission was induced by laser excitation, stimulating each spot automatically, in addition to controlling the humidity, temperature and incubation time of the enzymatic reaction. Results The measurement of standard glutamate concentrations was linear and could be performed in dialysis samples. This approach was used to determine the effect of the convulsant drugs bicuculline and 4-aminopyridine on the extracellular glutamate concentration. Seizure activity was associated with a considerable increase in glutamate that correlated with altered EEG patterns for both drugs. Conclusions These results indicate that this method is able to read samples with high temporal resolution, and it is easy to use compared with classical methods such as high-performance liquid chromatography, with the advantage that a large number of samples can be measured in a single experimental series. This method provides an alternative approach to determine the concentrations of neurotransmitters or other compounds that generate hydrogen peroxide as a reaction product.
Collapse
Affiliation(s)
- Laura Medina-Ceja
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico.
| | - Kenia Pardo-Peña
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico.
| | - Alberto Morales-Villagrán
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico. .,Laboratorio de Neurofisiología y Neuroquímica, Departamento de Biología Celular y Molecular, Centro Universitario de Ciencias Biológicas y Agropecuarias, Universidad de Guadalajara, Camino Ing. R. Padilla Sánchez 2100, Las Agujas, Nextipac, CP 45110, Zapopan, Jalisco, Mexico.
| | - Jorge Ortega-Ibarra
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico.
| | - Silvia López-Pérez
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico.
| |
Collapse
|
22
|
Cifuentes Castro VH, López Valenzuela CL, Salazar Sánchez JC, Peña KP, López Pérez SJ, Ibarra JO, Villagrán AM. An update of the classical and novel methods used for measuring fast neurotransmitters during normal and brain altered function. Curr Neuropharmacol 2014; 12:490-508. [PMID: 25977677 PMCID: PMC4428024 DOI: 10.2174/1570159x13666141223223657] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2014] [Revised: 11/22/2014] [Accepted: 12/19/2014] [Indexed: 11/22/2022] Open
Abstract
To understand better the cerebral functions, several methods have been developed to study the brain activity, they could be related with morphological, electrophysiological, molecular and neurochemical techniques. Monitoring neurotransmitter concentration is a key role to know better how the brain works during normal or pathological conditions, as well as for studying the changes in neurotransmitter concentration with the use of several drugs that could affect or reestablish the normal brain activity. Immediate response of the brain to environmental conditions is related with the release of the fast acting neurotransmission by glutamate (Glu), γ-aminobutyric acid (GABA) and acetylcholine (ACh) through the opening of ligand-operated ion channels. Neurotransmitter release is mainly determined by the classical microdialysis technique, this is generally coupled to high performance liquid chromatography (HPLC). Detection of neurotransmitters can be done by fluorescence, optical density, electrochemistry or other detection systems more sophisticated. Although the microdialysis method is the golden technique to monitor the brain neurotransmitters, it has a poor temporal resolution. Recently, with the use of biosensor the drawback of temporal resolution has been improved considerably, however other inconveniences have merged, such as stability, reproducibility and the lack of reliable biosensors mainly for GABA. The aim of this review is to show the important advances in the different ways to measure neurotransmitter concentrations; both with the use of classic techniques as well as with the novel methods and alternant approaches to improve the temporal resolution.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Alberto Morales Villagrán
- Department of Molecular and Cellular Biology, Camino Ramón Padilla Sánchez 2100, Nextipac, Zapopan,
Jalisco, México, Zip code: 45110, Mexico
| |
Collapse
|
23
|
Hegoburu C, Parrot S, Ferreira G, Mouly AM. Differential involvement of amygdala and cortical NMDA receptors activation upon encoding in odor fear memory. ACTA ACUST UNITED AC 2014; 21:651-5. [PMID: 25403452 PMCID: PMC4236412 DOI: 10.1101/lm.036558.114] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Although the basolateral amygdala (BLA) plays a crucial role for the acquisition of fear memories, sensory cortices are involved in their long-term storage in rats. However, the time course of their respective involvement has received little investigation. Here we assessed the role of the glutamatergic N-methyl-d-aspartate (NMDA) receptors in the BLA and olfactory cortex at discrete moments of an odor fear conditioning session. We showed that NMDA receptors in BLA are critically involved in odor fear acquisition during the first association but not during the next ones. In the cortex, NMDA receptor activation at encoding is not necessary for recent odor fear memory while its role in remote memory storage needs further investigation.
Collapse
Affiliation(s)
- Chloé Hegoburu
- Centre de Recherche en Neurosciences de Lyon, INSERM U1028, CNRS UMR5292, University Lyon1, Lyon, France
| | - Sandrine Parrot
- Centre de Recherche en Neurosciences de Lyon, INSERM U1028, CNRS UMR5292, University Lyon1, Lyon, France
| | - Guillaume Ferreira
- INRA, Nutrition et Neurobiologie Intégrée, UMR 1286, Bordeaux, France Université de Bordeaux, Nutrition et Neurobiologie Intégrée, Bordeaux, France
| | - Anne-Marie Mouly
- Centre de Recherche en Neurosciences de Lyon, INSERM U1028, CNRS UMR5292, University Lyon1, Lyon, France
| |
Collapse
|
24
|
A rapid and simple method for the determination of 3,4-dihydroxyphenylacetic acid, norepinephrine, dopamine, and serotonin in mouse brain homogenate by HPLC with fluorimetric detection. J Pharm Biomed Anal 2014; 98:266-70. [DOI: 10.1016/j.jpba.2014.05.039] [Citation(s) in RCA: 114] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2014] [Accepted: 05/29/2014] [Indexed: 11/19/2022]
|
25
|
Zapata A, Chefer VI, Parrot S, Denoroy L. Detection and quantification of neurotransmitters in dialysates. ACTA ACUST UNITED AC 2013; Chapter 7:Unit7.4. [PMID: 23559307 DOI: 10.1002/0471142301.ns0704s63] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Sensitive analytical methods are needed for the separation and quantification of neurotransmitters obtained in microdialysate studies. This unit describes methods that permit quantification of nanomolar concentrations of monoamines and their metabolites (high-performance liquid chromatography [HPLC] electrochemical detection), acetylcholine (HPLC-coupled to an enzyme reactor), and amino acids (HPLC-fluorescence detection, capillary electrophoresis with laser-induced fluorescence detection).
Collapse
Affiliation(s)
- Agustin Zapata
- National Institute on Drug Abuse Intramural Research Program, National Institutes of Health, Baltimore, Maryland, USA
| | | | | | | |
Collapse
|
26
|
Ladner Y, Crétier G, Faure K. Electrochromatography on acrylate-based monolith in cyclic olefin copolymer microchip: A cost-effective and easy-to-use technology. Electrophoresis 2012; 33:3087-94. [DOI: 10.1002/elps.201200238] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2012] [Revised: 07/27/2012] [Accepted: 08/03/2012] [Indexed: 11/09/2022]
Affiliation(s)
- Yoann Ladner
- Université de Lyon, Institut des Sciences Analytiques (UMR Université Lyon 1/CNRS 5280); Domaine universitaire de La Doua; Villeurbanne; France
| | - Gérard Crétier
- Université de Lyon, Institut des Sciences Analytiques (UMR Université Lyon 1/CNRS 5280); Domaine universitaire de La Doua; Villeurbanne; France
| | - Karine Faure
- Université de Lyon, Institut des Sciences Analytiques (UMR Université Lyon 1/CNRS 5280); Domaine universitaire de La Doua; Villeurbanne; France
| |
Collapse
|
27
|
Morales-Villagrán A, Beltrán-Ramírez R, López-Pérez SJ, Palomera-Ávalos V, Medina-Ceja L. A Capillary Fraction Collector Coupled to a Fluorescence Reader: A Novel Device to Continuously Quantify Glutamate During Microdialysis. Neurochem Res 2012; 37:1457-64. [DOI: 10.1007/s11064-012-0736-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2011] [Revised: 02/12/2012] [Accepted: 02/20/2012] [Indexed: 10/28/2022]
|
28
|
Colleran JJ, Breslin CB. Simultaneous electrochemical detection of the catecholamines and ascorbic acid at PEDOT/S-β-CD modified gold electrodes. J Electroanal Chem (Lausanne) 2012. [DOI: 10.1016/j.jelechem.2011.12.020] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
29
|
Shi X, Liang P, Song D, Yang W, Gao X. Quantification of γ-aminobutyric acid in the heads of houseflies (Musca domestica) and diamondback moths (Plutella xylostella (L.)), using capillary electrophoresis with laser-induced fluorescence detection. J Sep Sci 2012; 35:548-55. [DOI: 10.1002/jssc.201100802] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
30
|
Kim MJ, Kim BK, Kim SM, Park JS, Hong JK. Profiling analysis of catecholamines and polyamines in biological samples. ANALYTICAL SCIENCE AND TECHNOLOGY 2011. [DOI: 10.5806/ast.2011.24.5.319] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
31
|
Zhao HX, Mu H, Bai YH, Yu H, Hu YM. A rapid method for the determination of dopamine in porcine muscle by pre-column derivatization and HPLC with fluorescence detection. J Pharm Anal 2011; 1:208-212. [PMID: 29403701 PMCID: PMC5760804 DOI: 10.1016/j.jpha.2011.04.003] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2010] [Accepted: 04/06/2011] [Indexed: 11/29/2022] Open
Abstract
A rapid method has been developed based on the sample preparation procedure named as QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe), combined with reversed-phase high performance liquid chromatography with fluorescence detector and C18 column after pre-column derivatization using o-phthalaldehyde and 2-mercaptoethanol to determine dopamine in porcine muscle. Methanol and deionized water (0.1% acetic acid, v/v) with a ratio of 60:40 was used as mobile phase. The flow rate was 0.8 mL/min and dopamine was eluted within 15 min. The linearity range was 0.003-8 μg/mL with r=0.9992. The detection limit for dopamine was 4 μg/kg and the quantification limit was 9 μg/kg. Recovery studies were carried out at 0.1, 0.5 and 1.0 mg/kg fortification levels and the average recoveries obtained ranged from 90.4% to 98.2% with relative standard deviations between 3.5% and 8.1%. The method was found to be suitable for detection of dopamine in animal product tissues at the maximum residue level.
Collapse
Affiliation(s)
- Hong-Xia Zhao
- Chemistry Department of Science School, Xi'an Jiaotong University, Xi'an 710049, China
| | - Hui Mu
- Chemistry Department of Science School, Xi'an Jiaotong University, Xi'an 710049, China
| | - Yan-Hong Bai
- Chemistry Department of Science School, Xi'an Jiaotong University, Xi'an 710049, China
| | - Hu Yu
- Chemistry Department of Science School, Xi'an Jiaotong University, Xi'an 710049, China
| | - Ying-Mei Hu
- Chemistry Department of Science School, Xi'an Jiaotong University, Xi'an 710049, China
| |
Collapse
|
32
|
Slaney TR, Nie J, Hershey ND, Thwar PK, Linderman J, Burns MA, Kennedy RT. Push-pull perfusion sampling with segmented flow for high temporal and spatial resolution in vivo chemical monitoring. Anal Chem 2011; 83:5207-13. [PMID: 21604670 DOI: 10.1021/ac2003938] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Low-flow push-pull perfusion is a sampling method that yields better spatial resolution than competitive methods like microdialysis. Because of the low flow rates used (50 nL/min), it is challenging to use this technique at high temporal resolution which requires methods of collecting, manipulating, and analyzing nanoliter samples. High temporal resolution also requires control of Taylor dispersion during sampling. To meet these challenges, push-pull perfusion was coupled with segmented flow to achieve in vivo sampling at 7 s temporal resolution at 50 nL/min flow rates. By further miniaturizing the probe inlet, sampling with 200 ms resolution at 30 nL/min (pull only) was demonstrated in vitro. Using this method, L-glutamate was monitored in the striatum of anesthetized rats. Up to 500 samples of 6 nL each were collected at 7 s intervals, segmented by an immiscible oil and stored in a capillary tube. The samples were assayed offline for L-glutamate at a rate of 15 samples/min by pumping them into a reagent addition tee fabricated from Teflon where reagents were added for a fluorescent enzyme assay. Fluorescence of the resulting plugs was monitored downstream. Microinjection of 70 mM potassium in physiological buffered saline evoked l-glutamate concentration transients that had an average maxima of 4.5 ± 1.1 μM (n = 6 animals, 3-4 injections each) and rise times of 22 ± 2 s. These results demonstrate that low-flow push-pull perfusion with segmented flow can be used for high temporal resolution chemical monitoring and in complex biological environments.
Collapse
Affiliation(s)
- Thomas R Slaney
- University of Michigan, Department of Chemistry, 930 N. University Avenue, Ann Arbor, Michigan 48109, USA
| | | | | | | | | | | | | |
Collapse
|
33
|
Wang M, Hershey ND, Mabrouk OS, Kennedy RT. Collection, storage, and electrophoretic analysis of nanoliter microdialysis samples collected from awake animals in vivo. Anal Bioanal Chem 2011; 400:2013-23. [PMID: 21465093 PMCID: PMC3107505 DOI: 10.1007/s00216-011-4956-9] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2011] [Revised: 03/22/2011] [Accepted: 03/24/2011] [Indexed: 12/25/2022]
Abstract
Microdialysis sampling is an important tool for chemical monitoring in living systems. Temporal resolution is an important figure of merit that is determined by sampling frequency, assay sensitivity, and dispersion of chemical zones during transport from sampling device to fraction collector or analytical system. Temporal resolution has recently been improved by segmenting flow into plugs, so that nanoliter fractions are collected at intervals of 0.1-2 s, thus eliminating temporal distortion associated with dispersion in continuous flow. Such systems, however, have yet to be used with behaving subjects. Furthermore, long-term storage of nanoliter samples created by segmented flow has not been reported. In this work, we have addressed these challenges. A microdialysis probe was integrated to a plug generator that could be stably mounted onto behaving animals. Long-term storage of dialysate plugs was achieved by collecting plugs into high-purity perfluoroalkoxy tubes, placing the tube into hexane and then freezing at -80°C. Slow warming with even temperatures prevented plug coalescence during sample thawing. As a demonstration of the system, plugs were collected from the striatum of behaving rats using a 0.5-mm-long microdialysis probe. Resulting plugs were analyzed 1-4 days later by chip-based electrophoresis. To improve throughput of plug analysis over previous work, the speed of electrophoretic separation was increased by using forced air cooling and 1-butyl-2,3-dimethylimidazolium tetrafluoroborate as a separation buffer additive, allowing resolution of six neuroactive amino acids in 30 s. Concentration changes induced by K(+) microinjections were monitored with 10 s temporal resolution. The improvements reported in this work make it possible to apply segmented flow microdialysis to the study of behaving animals and enable experiments where the analytical system cannot be placed close to the animal.
Collapse
Affiliation(s)
- Meng Wang
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, MI 48109, USA
| | - Neil D. Hershey
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, MI 48109, USA
| | - Omar S. Mabrouk
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, MI 48109, USA
| | - Robert T. Kennedy
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, MI 48109, USA
- Department of Pharmacology, University of Michigan, Ann Arbor, MI 48109, USA
| |
Collapse
|
34
|
Szökő É, Tábi T. Analysis of biological samples by capillary electrophoresis with laser induced fluorescence detection. J Pharm Biomed Anal 2010; 53:1180-92. [DOI: 10.1016/j.jpba.2010.07.045] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2010] [Revised: 07/23/2010] [Accepted: 07/27/2010] [Indexed: 12/26/2022]
|
35
|
Wang S, Fan L, Zhou W. Sensitive Analysis of 5-(4,6-Dichloro-s-triazin-2-ylamino)fluorescein-Labeled Catecholamines by Mixed MEKC–LIF. Chromatographia 2010. [DOI: 10.1365/s10337-010-1796-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
36
|
Wang M, Slaney T, Mabrouk O, Kennedy RT. Collection of nanoliter microdialysate fractions in plugs for off-line in vivo chemical monitoring with up to 2 s temporal resolution. J Neurosci Methods 2010; 190:39-48. [PMID: 20447417 PMCID: PMC2885530 DOI: 10.1016/j.jneumeth.2010.04.023] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2010] [Revised: 04/23/2010] [Accepted: 04/23/2010] [Indexed: 10/19/2022]
Abstract
An off-line in vivo neurochemical monitoring approach was developed based on collecting nanoliter microdialysate fractions as an array of "plugs" segmented by immiscible oil in a piece of Teflon tubing. The dialysis probe was integrated with the plug generator in a polydimethlysiloxane microfluidic device that could be mounted on the subject. The microfluidic device also allowed derivatization reagents to be added to the plugs for fluorescence detection of analytes. Using the device, 2 nL fractions corresponding to 1-20 ms sampling times depending upon dialysis flow rate, were collected. Because axial dispersion was prevented between them, each plug acted as a discrete sample collection vial and temporal resolution was not lost by mixing or diffusion during transport. In vitro tests of the system revealed that the temporal resolution of the system was as good as 2 s and was limited by mass transport effects within the dialysis probe. After collection of dialysate fractions, they were pumped into a glass microfluidic chip that automatically analyzed the plugs by capillary electrophoresis with laser-induced fluorescence at 50 s intervals. By using a relatively low flow rate during transfer to the chip, the temporal resolution of the samples could be preserved despite the relatively slow analysis time. The system was used to detect rapid dynamics in neuroactive amino acids evoked by microinjecting the glutamate uptake inhibitor l-trans-pyrrolidine-2,4-dicarboxylic acid (PDC) or K(+) into the striatum of anesthetized rats. The resulted showed increases in neurotransmitter efflux that reached a peak in 20 s for PDC and 13 s for K(+).
Collapse
Affiliation(s)
- Meng Wang
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, MI 48109, USA
| | - Thomas Slaney
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, MI 48109, USA
| | - Omar Mabrouk
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, MI 48109, USA
| | - Robert T. Kennedy
- Department of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, MI 48109, USA
- Departmenat of Pharmacology, University of Michigan, Ann Arbor, MI 48109, USA
| |
Collapse
|
37
|
Wang M, Roman GT, Perry ML, Kennedy RT. Microfluidic chip for high efficiency electrophoretic analysis of segmented flow from a microdialysis probe and in vivo chemical monitoring. Anal Chem 2009; 81:9072-8. [PMID: 19803495 PMCID: PMC2784254 DOI: 10.1021/ac901731v] [Citation(s) in RCA: 93] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
An effective method for in vivo chemical monitoring is to couple sampling probes, such as microdialysis, to online analytical methods. A limitation of this approach is that in vivo chemical dynamics may be distorted by flow and diffusion broadening during transfer from sampling probe to analytical system. Converting a homogeneous sample stream to segmented flow can prevent such broadening. We have developed a system for coupling segmented microdialysis flow with chip-based electrophoresis. In this system, the dialysis probe is integrated with a PDMS chip that merges dialysate with fluorogenic reagent and segments the flow into 8-10 nL plugs at 0.3-0.5 Hz separated by perfluorodecalin. The plugs flow to a glass chip where they are extracted to an aqueous stream and analyzed by electrophoresis with fluorescence detection. The novel extraction system connects the segmented flow to an electrophoresis sampling channel by a shallow and hydrophilic extraction bridge that removes the entire aqueous droplet from the oil stream. With this approach, temporal resolution was 35 s and independent of distance between sampling and analysis. Electrophoretic analysis produced separation with 223,000 +/- 21,000 theoretical plates, 4.4% RSD in peak height, and detection limits of 90-180 nM for six amino acids. This performance was made possible by three key elements: (1) reliable transfer of plug flow to a glass chip; (2) efficient extraction of aqueous plugs from segmented flow; (3) electrophoretic injection suitable for high efficiency separation with minimal dilution of sample. The system was used to detect rapid concentration changes evoked by infusing glutamate uptake inhibitor into the striatum of anesthetized rats. These results demonstrate the potential of incorporating segmented flow into separations-based sensing schemes for studying chemical dynamics in vivo with improved temporal resolution.
Collapse
Affiliation(s)
- Meng Wang
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, USA
| | | | | | | |
Collapse
|
38
|
Hegoburu C, Sevelinges Y, Thevenet M, Gervais R, Parrot S, Mouly AM. Differential dynamics of amino acid release in the amygdala and olfactory cortex during odor fear acquisition as revealed with simultaneous high temporal resolution microdialysis. Learn Mem 2009; 16:687-97. [DOI: 10.1101/lm.1584209] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
39
|
Guihen E, O'Connor WT. Current separation and detection methods in microdialysis the drive towards sensitivity and speed. Electrophoresis 2009; 30:2062-75. [PMID: 19582708 DOI: 10.1002/elps.200900039] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
This review outlines some of the analytical challenges associated with the analysis of microdialysis (MD) samples, in particular, the minute complex sample volumes that are often encountered. In MD sampling many different low-molecular-weight molecules can be collected, but the research findings are often limited by the sensitivity, specificity, and reliability of the analytical technique that is coupled to the dialysis probe. Therefore it is critical that a lot of consideration is given in selecting the most suitable analytical method including the most appropriate detector. This review aims to highlight the strengths and weaknesses of a range of commonly used analytical methods employed in MD. In Section 1, a brief overview of the MD technique is described, followed by a discussion on some of the advantages and drawbacks of this sampling technique. Sections 2 and 3 examine analytical and other technical considerations regarding analysis, with special emphasis on the factors that specifically influence analytical detection. Section 4 outlines the most commonly employed analytical techniques used in MD, including HPLC coupled with various detectors. Detail is given regarding the LOD and LOQ for many applications using each detector. As MS is of such high importance in MD, a special sub-section has been devoted to it. The importance of CE is also highlighted, with specific applications described. In addition, analytical techniques that do not appear to have found routine use in MD are discussed. Section 5 is concerned with recent innovations in chemical separation techniques, in particular MCE and ultra-performance liquid chromatography. Specific applications of the coupling of these techniques with MD are highlighted, along with technical challenges associated with miniaturization. In the Section 6, the future outlook of MD is discussed. Techniques other than electrophoretic- and chromatographic based separation methods are outside the scope of this review.
Collapse
Affiliation(s)
- Elizabeth Guihen
- Graduate Entry Medical School and Material Surface Science Institute, University of Limerick, Limerick, Ireland.
| | | |
Collapse
|
40
|
Shi T, Tang T, Qian K, Wang F, Li J, Cao Y. High-performance liquid chromatographic method for determination of amino acids by precolumn derivatization with 4-chloro-3,5-dinitrobenzotrifluoride. Anal Chim Acta 2009; 654:154-61. [PMID: 19854347 DOI: 10.1016/j.aca.2009.09.027] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2009] [Revised: 09/17/2009] [Accepted: 09/18/2009] [Indexed: 11/16/2022]
Abstract
This work presents an high-performance liquid chromatography method for the determination of amino acids after precolumn derivatization with 4-chloro-3,5-dinitrobenzotrifluoride (CNBF) which can readily react with both primary and secondary amines. The precolumn derivatization conditions, including the CNBF concentration, reaction pH, temperature and reaction time were investigated for method optimization. In pH 9.0 borate buffer, the reaction of amino acids with CNBF was carried out at 60 degrees C for 30min, the optimized concentration of CNBF was 70mmol L(-1) and the molar ratio of amino acids to CNBF was 1:5.25. The chromatographic separation of 19 amino acids derivatives was performed on a Kromasil ODS C(18) column (250mm x 4.6mm, 5microm) with good reproducibility, and ultraviolet detection was applied at 260 nm. The mobile phase was a mixture of phase A (acetonitrile) and phase B (acetate buffer, acetonitrile, triethylamine; 82.8:17:0.2, pH 4.9), and the flow rate was 0.4mL min(-1). The separation of all the labeled amino acids was achieved within 45min at room temperature by gradient elution mode. The method linearity, calculated for each amino acid, had a correlation coefficient higher than 0.9979, in concentrations ranging from 9.60 to 3330.00 micromol L(-1). The detection limits of amino acids were 2.40-6.50micromol L(-1), at a signal-to-noise ratio of 3. The proposed method was applied for the determination of amino acids in beer with recoveries of 97.0-103.9% and relative standard deviations of 2.62-4.22%, respectively. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples.
Collapse
Affiliation(s)
- Tianyu Shi
- College of Agriculture and Biotechnology, China Agricultural University, No. 2 Yuanmingyuan West Road, Beijing 100193, China
| | | | | | | | | | | |
Collapse
|
41
|
Wang S, Luo Z, Wang W, Chen X, Hu Z. Simultaneous Determination of Dopamine, Epinephrine and 5-Hydroxytryptamine in Toad Venom and Common Yam Rhizome by MEKC. Chromatographia 2009. [DOI: 10.1365/s10337-009-1333-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
42
|
Zapata A, Chefer VI, Shippenberg TS, Denoroy L. Detection and quantification of neurotransmitters in dialysates. ACTA ACUST UNITED AC 2009; Chapter 7:Unit 7.4.1-30. [PMID: 19575473 DOI: 10.1002/0471142301.ns0704s48] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Sensitive analytical methods are needed for the separation and quantification of neurotransmitters obtained in microdialysate studies. This unit describes methods that permit quantification of nanomolar concentrations of monoamines and their metabolites (high-pressure liquid chromatography electrochemical detection), acetylcholine (HPLC-coupled to an enzyme reactor), and amino acids (HPLC-fluorescence detection; capillary electrophoresis with laser-induced fluorescence detection).
Collapse
Affiliation(s)
- Agustin Zapata
- NIH, NIDA Intramural Research Program, Baltimore, Maryland, USA
| | | | | | | |
Collapse
|
43
|
Glutamate sensing with enzyme-modified floating-gate field effect transistors. Biosens Bioelectron 2009; 24:2384-9. [DOI: 10.1016/j.bios.2008.12.012] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2008] [Revised: 12/05/2008] [Accepted: 12/05/2008] [Indexed: 11/19/2022]
|
44
|
|
45
|
Denoroy L, Parrot S, Renaud L, Renaud B, Zimmer L. In-capillary derivatization and capillary electrophoresis separation of amino acid neurotransmitters from brain microdialysis samples. J Chromatogr A 2008; 1205:144-9. [DOI: 10.1016/j.chroma.2008.07.043] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2008] [Revised: 07/10/2008] [Accepted: 07/16/2008] [Indexed: 11/29/2022]
|
46
|
Morales-Villagrán A, Sandoval-Salazar C, Medina-Ceja L. An Analytical Flow Injection System to Measure Glutamate in Microdialysis Samples Based on an Enzymatic Reaction and Electrochemical Detection. Neurochem Res 2008; 33:1592-8. [DOI: 10.1007/s11064-008-9704-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2007] [Accepted: 04/03/2008] [Indexed: 11/28/2022]
|
47
|
Tseng WL, Chen SM, Hsu CY, Hsieh MM. On-line concentration and separation of indolamines, catecholamines, and metanephrines in capillary electrophoresis using high concentration of poly(diallyldimethylammonium chloride). Anal Chim Acta 2008; 613:108-15. [DOI: 10.1016/j.aca.2008.02.049] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2007] [Revised: 02/25/2008] [Accepted: 02/26/2008] [Indexed: 10/22/2022]
|
48
|
Simultaneous glutamate and EEG activity measurements during seizures in rat hippocampal region with the use of an electrochemical biosensor. J Neurosci Methods 2008; 168:48-53. [DOI: 10.1016/j.jneumeth.2007.09.005] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2007] [Revised: 09/05/2007] [Accepted: 09/07/2007] [Indexed: 11/17/2022]
|
49
|
CE coupled with amperometric detection using a boron-doped diamond microelectrode: Validation of a method for endogenous norepinephrine analysis in tissue. Electrophoresis 2008; 29:441-7. [DOI: 10.1002/elps.200700398] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
50
|
Schultz KN, Kennedy RT. Time-resolved microdialysis for in vivo neurochemical measurements and other applications. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2008; 1:627-661. [PMID: 20636092 DOI: 10.1146/annurev.anchem.1.031207.113047] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Monitoring changes in chemical concentrations over time in complex environments is typically performed using sensors and spectroscopic techniques. Another approach is to couple sampling methods, such as microdialysis, with chromatographic, electrophoretic, or enzymatic assays. Recent advances of such coupling have enabled improvements in temporal resolution, multianalyte capability, and automation. In a sampling and analysis method, the temporal resolution is set by the mass sensitivity of the analytical method, analysis time, and zone dispersion during sampling. Coupling methods with high speed and mass sensitivity to microdialysis sampling help to reduce some of these contributions to yield methods with temporal resolution of seconds. These advances have been primarily used in monitoring neurotransmitters in vivo. This review covers the problems associated with chemical monitoring in the brain, recent advances in using microdialysis for time-resolved in vivo measurements, sample applications, and other potential applications of the technology such as determining reaction kinetics and process monitoring.
Collapse
Affiliation(s)
- Kristin N Schultz
- Department of Chemistry, University of Michigan, Ann Arbor, 48109, USA
| | | |
Collapse
|