1
|
Yoon JS, Jo D, Lee HS, Yoo SW, Lee TY, Hwang WS, Choi JM, Kim E, Kim SS, Suh-Kim H. Spatiotemporal Protein Atlas of Cell Death-Related Molecules in the Rat MCAO Stroke Model. Exp Neurobiol 2018; 27:287-298. [PMID: 30181691 PMCID: PMC6120968 DOI: 10.5607/en.2018.27.4.287] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Revised: 07/25/2018] [Accepted: 07/26/2018] [Indexed: 01/04/2023] Open
Abstract
Ischemic stroke and cerebral infarction triggered by the blockage of blood supply can cause damage to the brain via a complex series of pathological changes. Recently, diverse therapies have emerged as promising candidates for the treatment of stroke. These treatments exert therapeutic effects by acting on diverse target molecules and cells in different time windows from the acute to chronic phases. Here, using immunohistochemistry, we show pathophysiological changes in the brain microenvironment at the hyperacute (within 6 h), acute (1~3 days), subacute (7 days), and chronic (1 month) phases following ischemic injury. Ischemic injury in rats was induced by occluding the middle cerebral artery and was validated by magnetic resonance imaging. The progression of damage to the brain was evaluated by immunohistochemistry for NeuN+ neurons, GFAP+ astrocytes, and Iba1+ microglia, and by the emergence of the cell death-related molecules such as AIF, FAF1, and activated caspase-3. Our data regarding the spatial and temporal information on pathophysiological changes may warrant the investigation of the timing of administration of therapeutic treatments in preclinical studies with an animal model of stroke.
Collapse
Affiliation(s)
- Jeong Seon Yoon
- Department of Anatomy, Ajou University School of Medicine, Suwon 16499, Korea
| | - Darong Jo
- Department of Biomedical Sciences, Ajou Graduate School, Suwon 16499, Korea
| | - Hye-Sun Lee
- Department of Anatomy, Ajou University School of Medicine, Suwon 16499, Korea
| | - Seung-Wan Yoo
- Department of Anatomy, Ajou University School of Medicine, Suwon 16499, Korea
| | - Tae-Young Lee
- Department of Biomedical Sciences, Ajou Graduate School, Suwon 16499, Korea
| | - Woo Sup Hwang
- Department of Anatomy, Ajou University School of Medicine, Suwon 16499, Korea
| | - Jung-Mi Choi
- Department of Anatomy, Ajou University School of Medicine, Suwon 16499, Korea
| | - Eunhee Kim
- Department of Biological Sciences and Graduate School of New Drug Discovery and Development, Chungnam National University, Daejeon 34134, Korea
| | - Sung-Soo Kim
- Department of Anatomy, Ajou University School of Medicine, Suwon 16499, Korea
| | - Haeyoung Suh-Kim
- Department of Anatomy, Ajou University School of Medicine, Suwon 16499, Korea.,Department of Biomedical Sciences, Ajou Graduate School, Suwon 16499, Korea
| |
Collapse
|
2
|
Cheng YJ, Lang D, Caruthers SD, Efimov IR, Chen J, Wickline SA. Focal but reversible diastolic sheet dysfunction reflects regional calcium mishandling in dystrophic mdx mouse hearts. Am J Physiol Heart Circ Physiol 2012; 303:H559-68. [PMID: 22777417 DOI: 10.1152/ajpheart.00321.2012] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Cardiac dysfunction is a primary cause of patient mortality in Duchenne muscular dystrophy, potentially related to elevated cytosolic calcium. However, the regional versus global functional consequences of cellular calcium mishandling have not been defined in the whole heart. Here we sought for the first time to elucidate potential regional dependencies between calcium mishandling and myocardial fiber/sheet function as a manifestation of dystrophin-deficient (mdx) cardiomyopathy. Isolated-perfused hearts from 16-mo-old mdx (N = 10) and wild-type (WT; N = 10) were arrested sequentially in diastole and systole for diffusion tensor MRI quantification of myocardial sheet architecture and function. When compared with WT hearts, mdx hearts exhibited normal systolic sheet architecture but a lower diastolic sheet angle magnitude (|β|) in the basal region. The regional diastolic sheet dysfunction was normalized by reducing perfusate calcium concentrations. Optical mapping of calcium transients in isolated hearts (3 mdx and 4 WT) revealed a stretch-inducible regional defect of intracellular calcium reuptake, reflected by a 25% increase of decay times (T(50)) and decay constants, at the base of mdx hearts. The basal region of mdx hearts also exhibited greater fibrosis than did the apex, which matched the regional sheet dysfunction. We conclude that myocardial diastolic sheet dysfunction is observed initially in basal segments along with calcium mishandling, ultimately culminating in increased fibrosis. The preservation of relatively normal calcium reuptake and diastolic/systolic sheet mechanics throughout the rest of the heart, together with the rapid reversibility of functional defects by reducing cytosolic calcium, points to the significance of regional mechanical factors in the progression of the disease.
Collapse
Affiliation(s)
- Ya-Jian Cheng
- Cardiovascular Division, Washington University School of Medicine, Saint Louis, Missouri 63110, USA
| | | | | | | | | | | |
Collapse
|
3
|
Chen F, Ni YC. Magnetic resonance diffusion-perfusion mismatch in acute ischemic stroke: An update. World J Radiol 2012; 4:63-74. [PMID: 22468186 PMCID: PMC3314930 DOI: 10.4329/wjr.v4.i3.63] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2011] [Revised: 02/22/2012] [Accepted: 03/01/2012] [Indexed: 02/06/2023] Open
Abstract
The concept of magnetic resonance perfusion-diffusion mismatch (PDM) provides a practical and approximate measure of the tissue at risk and has been increasingly applied for the evaluation of hyperacute and acute stroke in animals and patients. Recent studies demonstrated that PDM does not optimally define the ischemic penumbra; because early abnormality on diffusion-weighted imaging overestimates the infarct core by including part of the penumbra, and the abnormality on perfusion weighted imaging overestimates the penumbra by including regions of benign oligemia. To overcome these limitations, many efforts have been made to optimize conventional PDM. Various alternatives beyond the PDM concept are under investigation in order to better define the penumbra. The PDM theory has been applied in ischemic stroke for at least three purposes: to be used as a practical selection tool for stroke treatment; to test the hypothesis that patients with PDM pattern will benefit from treatment, while those without mismatch pattern will not; to be a surrogate measure for stroke outcome. The main patterns of PDM and its relation with clinical outcomes were also briefly reviewed. The conclusion was that patients with PDM documented more reperfusion, reduced infarct growth and better clinical outcomes compared to patients without PDM, but it was not yet clear that thrombolytic therapy is beneficial when patients were selected on PDM. Studies based on a larger cohort are currently under investigation to further validate the PDM hypothesis.
Collapse
|
4
|
Quantitative proton MRI and MRS of the rat brain with a 3T clinical MR scanner. J Neuroradiol 2011; 38:90-7. [DOI: 10.1016/j.neurad.2009.11.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2009] [Revised: 11/03/2009] [Accepted: 11/13/2009] [Indexed: 11/21/2022]
|
5
|
Chen F. Feng Chen's work on translational and clinical imaging. World J Radiol 2011; 3:120-4. [PMID: 21532873 PMCID: PMC3084436 DOI: 10.4329/wjr.v3.i4.120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2010] [Revised: 03/28/2011] [Accepted: 04/04/2011] [Indexed: 02/06/2023] Open
Abstract
Dr. Feng Chen is a chief medical doctor and the vice chairman of the Department of Radiology in Zhong Da Hospital at Southeast University, Nanjing, China and a senior researcher in the Department of Radiology at the Catholic University of Leuven, Belgium. His main areas of interest are translational imaging research including stroke, tumor angiogenesis, assessment of therapeutic response in solid tumors, and magnetic resonance contrast media. Dr. Feng Chen has published 44 scientific papers in peer-reviewed international journals. He and his colleagues have developed an imaging platform which includes animal models, animal preparations and multiparametric magnetic resonance imaging (MRI) protocols for translational animal imaging research using clinical machines. His MRI findings on rodent stroke are considered to "serve as a model for future laboratory investigations of treatment of acute stroke and unify the approaches developed for clinical studies". He and his colleagues have introduced a novel liver tumor model in rodents, in which a series of studies concerning the antitumor activity of vascular disrupting agents have been successively conducted and assessed by in vivo MRI, especially by diffusion weighted imaging as an imaging biomarker. His goal is to provide valuable references for clinical practice and to contribute to the translation of animal imaging research into patient applications.
Collapse
|
6
|
Park JW, Kim HJ, Song GS, Han HS. Blood-brain barrier experiments with clinical magnetic resonance imaging and an immunohistochemical study. J Korean Neurosurg Soc 2010; 47:203-9. [PMID: 20379473 DOI: 10.3340/jkns.2010.47.3.203] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2009] [Revised: 02/01/2010] [Accepted: 02/21/2010] [Indexed: 11/27/2022] Open
Abstract
OBJECTIVE The purpose of study was to evaluate the feasibility of brain magnetic resonance (MR) images of the rat obtained using a 1.5T MR machine in several blood-brain barrier (BBB) experiments. METHODS Male Sprague-Dawley rats were used. MR images were obtained using a clinical 1.5T MR machine. A microcatheter was introduced via the femoral artery to the carotid artery. Normal saline (group 1, n = 4), clotted autologous blood (group 2, n = 4), triolein emulsion (group 3, n = 4), and oleic acid emulsion (group 4, n = 4) were infused into the carotid artery through a microcatheter. Conventional and diffusion-weighted images, the apparent coefficient map, perfusion-weighted images, and contrast-enhanced MR images were obtained. Brain tissue was obtained and triphenyltetrazolium chloride (TTC) staining was performed in group 2. Fluorescein isothiocyanate (FITC)-labeled dextran images and endothelial barrier antigen (EBA) studies were performed in group 4. RESULTS The MR images in group 1 were of good quality. The MR images in group 2 revealed typical findings of acute cerebral infarction. Perfusion defects were noted on the perfusion-weighted images. The MR images in group 3 showed vasogenic edema and contrast enhancement, representing vascular damage. The rats in group 4 had vasogenic edema on the MR images and leakage of dextran on the FITC-labeled dextran image, representing increased vascular permeability. The immune reaction was decreased on the EBA study. CONCLUSION Clinical 1.5T MR images using a rat depicted many informative results in the present study. These results can be used in further researches of the BBB using combined clinical MR machines and immunohistochemical examinations.
Collapse
Affiliation(s)
- Jun Woo Park
- Department of Neurosurgery, College of Medicine & Medical Research Institute, Pusan National University, Yangsan, Korea
| | | | | | | |
Collapse
|
7
|
Rodríguez I, Pérez-Rial S, González-Jimenez J, Pérez-Sánchez J, Herranz F, Beckmann N, Ruíz-Cabello J. Magnetic resonance methods and applications in pharmaceutical research. J Pharm Sci 2008; 97:3637-65. [PMID: 18228597 DOI: 10.1002/jps.21281] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
This review presents an overview of some recent magnetic resonance (MR) techniques for pharmaceutical research. MR is noninvasive, and does not expose subjects to ionizing radiation. Some methods that have been used in pharmaceutical research MR include magnetic resonance spectroscopy (MRS) and magnetic resonance imaging (MRI) methods, among them, diffusion-weighted MRI, perfusion-weighted MRI, functional MRI, molecular imaging and contrast-enhance MRI. Some applications of MR in pharmaceutical research include MR in metabonomics, in vivo MRS, studies in cerebral ischemia and infarction, degenerative joint diseases, oncology, cardiovascular disorders, respiratory diseases and skin diseases. Some of these techniques, such as cardiac and joint imaging, or brain fMRI are standard, and are providing relevant data routinely. Skin MR and hyperpolarized gas lung MRI are still experimental. In conclusion, considering the importance of finding and characterizing biomarkers for improved drug evaluation, it can be expected that the use of MR techniques in pharmaceutical research is going to increase in the near future.
Collapse
Affiliation(s)
- I Rodríguez
- Grupo de Resonancia Magnética, Instituto de Estudios Biofuncionales, Universidad Complutense de Madrid, Paseo Juan XXIII 1, Madrid 28040, Spain
| | | | | | | | | | | | | |
Collapse
|
8
|
Legos JJ, Lenhard SC, Haimbach RE, Schaeffer TR, Bentley RG, McVey MJ, Chandra S, Irving EA, Andrew A. Parsons, Barone FC. SB 234551 selective ETA receptor antagonism: Perfusion/Diffusion MRI used to define treatable stroke model, time to treatment and mechanism of protection. Exp Neurol 2008; 212:53-62. [DOI: 10.1016/j.expneurol.2008.03.011] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2007] [Revised: 02/29/2008] [Accepted: 03/03/2008] [Indexed: 10/22/2022]
|
9
|
Chen F, Liu Q, Wang H, Suzuki Y, Nagai N, Yu J, Marchal G, Ni Y. Comparing two methods for assessment of perfusion-diffusion mismatch in a rodent model of ischaemic stroke: a pilot study. Br J Radiol 2008; 81:192-8. [PMID: 18180261 DOI: 10.1259/bjr/70940134] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
This stroke experiment was designed to define the mismatch between perfusion-weighted imaging (PWI) and diffusion-weighted imaging (DWI) in MRI by applying early or instantly acquired PWI. Eight rats were induced with stroke through photothrombotic occlusion of the middle cerebral artery and scanned serially between 1 h and day 3 after induction using DWI and PWI with a 1.5 T MR scanner. The relative lesion volumes (rLV) on MRI and triphenyl tetrazolium chloride-stained specimens were defined as the proportion of lesion volume over brain volume. Discrepancies in the rLV between PWI- and DWI-derived apparent diffusion coefficient (ADC) maps were expressed by subtraction of the ADC from PWI, resulting in three possible patterns: (i) (PWI-ADC > 10% of PWI) denoting a mismatch; (ii) (-(10% of PWI) <or= PWI-ADC <or= 10% of PWI) denoting a match; and (iii) (PWI-ADC < -(10% of PWI)) denoting a reverse mismatch. The differences were compared with the minuend being either early PWI (ePWI) or instant PWI (iPWI) and the subtrahend being instant ADC (iADC). The occurrence and evolution of PWI-ADC patterns were analysed. Over time, PWI-ADC discrepancies evolved from mismatch, through to match, to reversed mismatch. The PWI-ADC mismatch still existed 3 days after MCA occlusion in one to three of the eight cases. The rLVs and mismatch incidences between the ePWI-iADC and iPWI-iADC models were linear correlated. A higher mismatch rate occurred in iPWI-iADC within day 1 and in ePWI-iADC at day 3. Both ePWI and iPWI proved useful to define PWI-ADC patterns within day 1. At day 3, iPWI appeared more adequate.
Collapse
Affiliation(s)
- F Chen
- Department of Radiology, University Hospitals, Catholic University of Leuven, Herestraat 49, B-3000 Leuven, Belgium
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Linn J, Schwarz F, Schichor C, Wiesmann M. Cranial MRI of small rodents using a clinical MR scanner. Methods 2007; 43:2-11. [PMID: 17720558 DOI: 10.1016/j.ymeth.2007.03.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2006] [Revised: 01/19/2007] [Accepted: 03/27/2007] [Indexed: 11/20/2022] Open
Abstract
Increasing numbers of small animal models are in use in the field of neuroscience research. Magnetic resonance imaging (MRI) provides an excellent method for non-invasive imaging of the brain. Using three-dimensional (3D) MR sequences allows lesion volumetry, e.g. for the quantification of tumor size. Specialized small-bore animal MRI scanners are available for high-resolution MRI of small rodents' brain, but major drawbacks of this dedicated equipment are its high costs and thus its limited availability. Therefore, more and more research groups use clinical MR scanners for imaging small animal models. But to achieve a reasonable spatial resolution at an acceptable signal-to-noise ratio with these scanners, some requirements concerning sequence parameters have to be matched. Thus, the aim of this paper was to present in detail a method how to perform MRI of small rodents brain using a standard clinical 1.5 T scanner and clinically available radio frequency coils to keep material costs low and to circumvent the development of custom-made coils.
Collapse
Affiliation(s)
- Jennifer Linn
- Department of Neuroradiology, University Hospital Munich, Grosshadern, Marchioninistrasse 15, 81377 Munich, Germany.
| | | | | | | |
Collapse
|
11
|
Brockmann MA, Kemmling A, Groden C. Current issues and perspectives in small rodent magnetic resonance imaging using clinical MRI scanners. Methods 2007; 43:79-87. [PMID: 17720566 DOI: 10.1016/j.ymeth.2007.07.001] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2007] [Accepted: 07/10/2007] [Indexed: 12/16/2022] Open
Abstract
Small rodents such as mice and rats are frequently used in animal experiments for several reasons. In the past, animal experiments were frequently associated with invasive methods and groups of animals had to be killed to perform longitudinal studies. Today's modern imaging techniques such as magnetic resonance imaging (MRI) allow non-invasive longitudinal monitoring of multiple parameters. Although only a few institutions have access to dedicated small animal MR scanners, most institutions carrying out animal experiments have access to clinical MR scanners. Technological advances and the increasing field strength of clinical scanners make MRI a broadly available and viable technique in preclinical in vivo research. This review provides an overview of current concepts, limitations, and recent studies dealing with small animal imaging using clinical MR scanners.
Collapse
Affiliation(s)
- Marc A Brockmann
- Department of Neuroradiology, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 61867 Mannheim, Germany.
| | | | | |
Collapse
|
12
|
Chen F, Suzuki Y, Nagai N, Sun X, Wang H, Yu J, Marchal G, Ni Y. Microplasmin and tissue plasminogen activator: comparison of therapeutic effects in rat stroke model at multiparametric MR imaging. Radiology 2007; 244:429-38. [PMID: 17581889 DOI: 10.1148/radiol.2442061316] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively compare therapeutic and hemorrhagic effects of microplasmin and tissue plasminogen activator (tPA) in stroke therapy by using multiparametric magnetic resonance (MR) imaging in a photothrombotic rat stroke model. MATERIALS AND METHODS The animal experiment complied with institutional regulations for laboratory animals. Stroke was induced in rats with photothrombotic occlusion of middle cerebral artery (MCA). T2-weighted, perfusion-weighted (PW), and diffusion-weighted (DW) MR imaging was performed 1 hour and 24 hours after occlusion. On the basis of PW and DW images at 1 hour, 49 rats with cortex and subcortex involvement and with perfusion-diffusion mismatch were randomly assigned into one of four groups: control group, group treated with 7.5 mg microplasmin, group treated with 10 mg/kg microplasmin, or group treated with 10 mg/kg tPA. Agents were intravenously injected 1.5 hours after occlusion. Infarct size and hemorrhagic transformation were assessed with MR imaging and histomorphologic findings. Neurologic deficit was scored. Measurements were statistically analyzed. RESULTS There were 13 rats in the control group, 13 in the 7.5 mg/kg microplasmin group, nine in the 10 mg/kg microplasmin group, and 14 in the 10 mg/kg tPA group. Despite similar baseline perfusion-diffusion mismatch, histochemically defined total infarct volume was reduced from 25% +/- 5 (standard deviation) in control group to 21% +/- 2, 20% +/- 4, and 20% +/- 5 in 7.5 mg/kg microplasmin, 10 mg/kg microplasmin, and tPA groups, respectively, as similarly shown on T2-weighted, DW, and PW images at 24 hours (P < .05). Cerebral hemorrhage rate at 24 hours was higher in tPA group than in the other three groups. Bederson score of neurologic deficits was significantly reduced in treated groups compared with that in control group. CONCLUSION Perfusion-diffusion mismatch appeared useful in selecting candidates for thrombolytic therapy. Multiparametric MR imaging allowed noninvasive assessment of effects of microplasmin and tPA in rats; microplasmin had a significantly lower hemorrhagic rate.
Collapse
Affiliation(s)
- Feng Chen
- Department of Radiology, University Hospitals, University of Leuven, Herestraat 49, B-3000 Leuven, Belgium
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Chen F, Suzuki Y, Nagai N, Sun X, Coudyzer W, Yu J, Marchal G, Ni Y. Delayed perfusion phenomenon in a rat stroke model at 1.5T MR: An imaging sign parallel to spontaneous reperfusion and ischemic penumbra? Eur J Radiol 2007; 61:70-8. [PMID: 17045441 DOI: 10.1016/j.ejrad.2006.08.019] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2006] [Revised: 08/14/2006] [Accepted: 08/16/2006] [Indexed: 10/24/2022]
Abstract
INTRODUCTION Delayed perfusion (DP) sign at MR imaging was reported in stroke patients. We sought to experimentally elucidate its relation to spontaneous reperfusion and ischemic penumbra. METHODS Stroke was induced by photothrombotic occlusion of middle cerebral artery in eight rats and studied up to 72 h using a 1.5 T MR scanner with T2 weighted imaging (T2WI), diffusion weighted imaging (DWI), and dynamic susceptibility contrast-enhanced perfusion weighted imaging (DSC-PWI). Relative signal intensity (rSI), relative lesion volume (rLV), relative cerebral blood flow (rCBF), PWI(rLV)-DWI(rLV) mismatch (penumbra) and DP(rLV) were quantified and correlated with neurological deficit score (NDS), triphenyl tetrazolium chloride (TTC) staining, microangiography (MA) and histopathology. RESULTS The rSI and rLV characterized this stroke model on different MRI sequences and time points. DSC-PWI reproduced cortical DP in all rats, where rCBF evolved from 88.9% at 1 h through 64.9% at 6 h to 136.3% at 72 h. The PWI(rLV)-DWI(rLV) mismatch reached 10+/-5.4% at 1 h, remained positive through 12 h and decreased to -3.3+/-4.5% at 72 h. The incidence and rLV of the DP were well correlated with those of the penumbra (p<0.01, r(2)=0.85 and p<0.0001, r(2)=0.96, respectively). Shorter DP durations and more collateral arterioles occurred in rats without (n=4) than with (n=4) cortex involvement (p<0.05). Rats without cortex involvement tended to earlier reperfusion and a lower NDS. Microscopy confirmed MRI, MA and TTC findings. CONCLUSIONS In this rat stroke model, we reproduced clinically observed DP on DSC-PWI, confirmed spontaneous reperfusion, and identified the penumbra extending to 12h post-ischemia, which appeared interrelated.
Collapse
Affiliation(s)
- Feng Chen
- Department of Radiology, University Hospitals, Catholic University of Leuven, Herestraat 49, B-3000 Leuven, Belgium
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Sicard KM, Henninger N, Fisher M, Duong TQ, Ferris CF. Differential recovery of multimodal MRI and behavior after transient focal cerebral ischemia in rats. J Cereb Blood Flow Metab 2006; 26:1451-62. [PMID: 16538230 PMCID: PMC2962954 DOI: 10.1038/sj.jcbfm.9600299] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The association between recovery of brain function and behavior after transient cerebral ischemia in animals and humans is incompletely characterized. Quantitative diffusion- (DWI), perfusion- (PWI), T(2)-weighted (T(2)WI), and functional magnetic resonance imaging (fMRI) were performed before, during, and up to 1 day after 20-mins transient middle cerebral artery occlusion (tMCAO; n=6) or sham operation (n=6) in male Sprague-Dawley rats. Viability thresholds were employed to calculate diffusion, perfusion, and T(2) lesion volumes. Region of interest analysis was used to evaluate structural and functional MR signal changes within the sensorimotor network, which were then related to corresponding behavioral measures. Post-mortem 2,3,5-triphenyltetrazolium chloride (TTC) staining was performed 24 h after ischemia. Transient middle cerebral artery occlusion produced lesions on DWI and PWI, which fully recovered by 30 mins after reperfusion. Ipsilesional fMRI responses to hypercapnia and forepaw stimulation were significantly impaired after ischemia and did not fully normalize until 3 and 24 h after tMCAO, respectively. No abnormalities were observed on imaging or TTC at 24 h despite significant behavioral dysfunctions including contralesional forelimb impairment and ipsilesional neglect. No MRI, behavioral, or TTC anomalies were observed in sham-operated rats. There were no significant correlations between MRI parameters, behavior, and TTC in either group. Together, these results suggest that normal findings on diffusion, perfusion, and T(2) imaging shortly after transient ischemia may not indicate normal tissue status as indicated by fMRI and behavior, which may help explain the persistence of neurologic deficits in patients with normal conventional MRI after cerebral ischemia.
Collapse
Affiliation(s)
- Kenneth M Sicard
- Department of Psychiatry, Center for Comparative NeuroImaging, University of Massachusetts Medical School, Worcester, Massachusetts 01604, USA.
| | | | | | | | | |
Collapse
|
15
|
Yushmanov VE, Kharlamov A, Simplaceanu E, Williams DS, Jones SC. Differences between arterial occlusive and cortical photothrombosis stroke models with magnetic resonance imaging and microtubule-associated protein-2 immunoreactivity. Magn Reson Imaging 2006; 24:1087-93. [PMID: 16997079 DOI: 10.1016/j.mri.2006.04.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2006] [Revised: 04/04/2006] [Indexed: 11/16/2022]
Abstract
The differences between two models of cerebral ischemia [middle cerebral arterial transection (MCAT) and cortical photothrombosis (PT)] were explored with multiparametric MRI of apparent diffusion coefficient trace (ADCtr), cerebral blood flow (CBF) and T1. Microtubule-associated protein-2 (MAP2) immunoreactivity sections aligned with the MR images in the same coronal plane were used to map the infarct and to guide region-of-interest selection. In ischemic cortex, the larger T1 increase in PT versus MCAT (42+/-7% vs. 16+/-5%) is related to the different character of edema between these models; yet, neither CBF nor ADCtr discriminated between them at 3.5 h, suggesting that different mechanisms of ischemic damage to the brain cells resulted in the same ADCtr value. CBF and ADCtr were depressed in immediately adjacent ischemic border by 27+/-7% and 47+/-10%, respectively, in MCAT but not in PT, suggesting marginal perfusion in MCAT. CBF in homotopic normal cortex in the opposite hemisphere was higher for PT compared with MCAT (199+/-20 and 134+/-10 ml/100 g/min, respectively). Different pathological processes in the two models affect CBF, ADCtr and T1 in a unique, regionally specific manner. The PT model differs substantially from the MCAT and is not a model of cortical ischemia with an appreciable border zone.
Collapse
Affiliation(s)
- Victor E Yushmanov
- Department of Anesthesiology, Allegheny-Singer Research Institute, Pittsburgh, PA 15212-4772, USA.
| | | | | | | | | |
Collapse
|