1
|
Chlupac J, Frank J, Sedmera D, Fabian O, Simunkova Z, Mrazova I, Novak T, Vanourková Z, Benada O, Pulda Z, Adla T, Kveton M, Lodererova A, Voska L, Pirk J, Fronek J. External Support of Autologous Internal Jugular Vein Grafts with FRAME Mesh in a Porcine Carotid Artery Model. Biomedicines 2024; 12:1335. [PMID: 38927542 PMCID: PMC11201386 DOI: 10.3390/biomedicines12061335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 05/28/2024] [Accepted: 06/12/2024] [Indexed: 06/28/2024] Open
Abstract
BACKGROUND Autologous vein grafts are widely used for bypass procedures in cardiovascular surgery. However, these grafts are susceptible to failure due to vein graft disease. Our study aimed to evaluate the impact of the latest-generation FRAME external support on vein graft remodeling in a preclinical model. METHODS We performed autologous internal jugular vein interposition grafting in porcine carotid arteries for one month. Four grafts were supported with a FRAME mesh, while seven unsupported grafts served as controls. The conduits were examined through flowmetry, angiography, macroscopy, and microscopy. RESULTS The one-month patency rate of FRAME-supported grafts was 100% (4/4), whereas that of unsupported controls was 43% (3/7, Log-rank p = 0.071). On explant angiography, FRAME grafts exhibited significantly more areas with no or mild stenosis (9/12) compared to control grafts (3/21, p = 0.0009). Blood flow at explantation was higher in the FRAME grafts (145 ± 51 mL/min) than in the controls (46 ± 85 mL/min, p = 0.066). Area and thickness of neo-intimal hyperplasia (NIH) at proximal anastomoses were similar for the FRAME and the control groups: 5.79 ± 1.38 versus 6.94 ± 1.10 mm2, respectively (p = 0.558) and 480 ± 95 vs. 587 ± 52 μm2/μm, respectively (p = 0.401). However, in the midgraft portions, the NIH area and thickness were significantly lower in the FRAME group than in the control group: 3.73 ± 0.64 vs. 6.27 ± 0.64 mm2, respectively (p = 0.022) and 258 ± 49 vs. 518 ± 36 μm2/μm, respectively (p = 0.0002). CONCLUSIONS In our porcine model, the external mesh FRAME improved the patency of vein-to-carotid artery grafts and protected them from stenosis, particularly in the mid regions. The midgraft neo-intimal hyperplasia was two-fold thinner in the meshed grafts than in the controls.
Collapse
Affiliation(s)
- Jaroslav Chlupac
- Transplantation Surgery Department, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (J.F.); (T.N.); (J.F.)
- Department of Anatomy, Second Faculty of Medicine, Charles University, V Uvalu 84, 150 06 Prague, Czech Republic
| | - Jan Frank
- Transplantation Surgery Department, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (J.F.); (T.N.); (J.F.)
| | - David Sedmera
- Institute of Anatomy, First Faculty of Medicine, Charles University, U Nemocnice 3, Praha 2, 128 00 Prague, Czech Republic;
| | - Ondrej Fabian
- Clinical and Transplant Pathology Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (O.F.); (M.K.); (A.L.); (L.V.)
- Department of Pathology and Molecular Medicine, Third Faculty of Medicine, Charles University, and Thomayer University Hospital, Ruska 87, 100 00 Prague, Czech Republic
| | - Zuzana Simunkova
- Experimental Medicine Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (Z.S.); (I.M.); (Z.V.)
| | - Iveta Mrazova
- Experimental Medicine Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (Z.S.); (I.M.); (Z.V.)
| | - Tomas Novak
- Transplantation Surgery Department, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (J.F.); (T.N.); (J.F.)
| | - Zdenka Vanourková
- Experimental Medicine Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (Z.S.); (I.M.); (Z.V.)
| | - Oldrich Benada
- Laboratory of Molecular Structure Characterization, Institute of Microbiology of the Czech Academy of Sciences, Vídeňská 1083, 142 00 Prague, Czech Republic;
| | - Zdenek Pulda
- Department of Imaging Methods, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (Z.P.); (T.A.)
| | - Theodor Adla
- Department of Imaging Methods, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (Z.P.); (T.A.)
| | - Martin Kveton
- Clinical and Transplant Pathology Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (O.F.); (M.K.); (A.L.); (L.V.)
- Third Faculty of Medicine, Charles University, Ruska 87, 100 00 Prague, Czech Republic
| | - Alena Lodererova
- Clinical and Transplant Pathology Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (O.F.); (M.K.); (A.L.); (L.V.)
| | - Ludek Voska
- Clinical and Transplant Pathology Centre, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (O.F.); (M.K.); (A.L.); (L.V.)
| | - Jan Pirk
- Cardiovascular Surgery Department, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic;
| | - Jiri Fronek
- Transplantation Surgery Department, Institute for Clinical and Experimental Medicine (IKEM), Videnska 1958/9, 140 21 Prague, Czech Republic; (J.F.); (T.N.); (J.F.)
- Department of Anatomy, Second Faculty of Medicine, Charles University, V Uvalu 84, 150 06 Prague, Czech Republic
- First Surgical Clinic, First Faculty of Medicine, Charles University, U Nemocnice 499/2, 128 08 Prague, Czech Republic
| |
Collapse
|
2
|
Mikami T, Dashwood MR, Kawaharada N, Furuhashi M. An Obligatory Role of Perivascular Adipose Tissue in Improved Saphenous Vein Graft Patency in Coronary Artery Bypass Grafting. Circ J 2024; 88:845-852. [PMID: 37914280 DOI: 10.1253/circj.cj-23-0581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2023]
Abstract
The gold standard graft for coronary artery bypass grafting (CABG) is the internal thoracic artery (ITA), and the second recommendation is the radial artery. However, complete revascularization with arterial grafts alone is often difficult, and the saphenous vein (SV) is the most commonly used autologous graft for CABG, because it is easier to use without restriction for the length of the graft. On the other hand, the patency of SV grafts (SVGs) is poor compared with that of arterial grafts. The SVG is conventionally harvested as a distended conduit with surrounding tissue removed, a procedure that may cause vascular damage. A no-touch technique of SVG harvesting has been reported to result in improved long-term patency in CABG comparable to that when using the ITA for grafting. Possible reasons for the excellent long-term patency of no-touch SVGs are the physical support provided by preserved surrounding perivascular adipose tissue, preservation of the vascular wall structure including the vasa vasorum, and production of adipocyte-derived factors. In this review, we discuss recent strategies aimed at improving the performance of SVGs, including no-touch harvesting, minimally invasive harvesting and mechanical support using external stents.
Collapse
Affiliation(s)
- Takuma Mikami
- Department of Cardiovascular Surgery, Sapporo Medical University
| | - Michael R Dashwood
- Surgical and Interventional Sciences, Royal Free Hospital Campus, University College London Medical School
| | | | - Masato Furuhashi
- Department of Cardiovascular, Renal and Metabolic Medicine, Sapporo Medical University
| |
Collapse
|
3
|
Gemelli M, Addonizio M, Geatti V, Gallo M, Dixon LK, Slaughter MS, Gerosa G. Techniques and Technologies to Improve Vein Graft Patency in Coronary Surgery. Med Sci (Basel) 2024; 12:6. [PMID: 38249082 PMCID: PMC10801616 DOI: 10.3390/medsci12010006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/22/2023] [Accepted: 01/05/2024] [Indexed: 01/23/2024] Open
Abstract
Vein grafts are the most used conduits in coronary artery bypass grafting (CABG), even though many studies have suggested their lower patency compared to arterial alternatives. We have reviewed the techniques and technologies that have been investigated over the years with the aim of improving the quality of these conduits. We found that preoperative and postoperative optimal medical therapy and no-touch harvesting techniques have the strongest evidence for optimizing vein graft patency. On the other hand, the use of venous external support, endoscopic harvesting, vein preservation solution and anastomosis, and graft configuration need further investigation. We have also analyzed strategies to treat vein graft failure: when feasible, re-doing the CABG and native vessel primary coronary intervention (PCI) are the best options, followed by percutaneous procedures targeting the failed grafts.
Collapse
Affiliation(s)
- Marco Gemelli
- Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, 35128 Padova, Italy; (M.A.); (V.G.); (G.G.)
| | - Mariangela Addonizio
- Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, 35128 Padova, Italy; (M.A.); (V.G.); (G.G.)
| | - Veronica Geatti
- Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, 35128 Padova, Italy; (M.A.); (V.G.); (G.G.)
| | - Michele Gallo
- Department of Cardiothoracic Surgery, University of Louisville, Louisville, KY 40292, USA; (M.G.); (M.S.S.)
| | - Lauren K. Dixon
- Clinical Effectiveness Unit, The Royal College of Surgeons of England, London WC2A 3PE, UK;
| | - Mark S. Slaughter
- Department of Cardiothoracic Surgery, University of Louisville, Louisville, KY 40292, USA; (M.G.); (M.S.S.)
| | - Gino Gerosa
- Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, 35128 Padova, Italy; (M.A.); (V.G.); (G.G.)
| |
Collapse
|
4
|
Wang Y, Fu M, Xiao W, Zhao Y, Yuan P, Zhang X, Wu W. 3D Elastomeric Stent Functionalized with Antioxidative and Perivascular Tissue Regenerative Activities Ameliorated PVT Deprivation-Induced Vein Graft Failure. Adv Healthc Mater 2023; 12:e2301247. [PMID: 37440681 DOI: 10.1002/adhm.202301247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 07/10/2023] [Accepted: 07/12/2023] [Indexed: 07/15/2023]
Abstract
Clinically, arterial injuries are always accompanied with perivascular tissue damage, which may contribute to high failure rate of vein grafts due to intimal hyperplasia and acute thrombosis. In this study, a "perivascular tissue (PVT) deprivation" animal model is constructed to mimic clinical scenarios and identify the contribution of arterial PVT to the success of vein grafts. Proteomics analysis suggests that depriving PVT may exacerbate reactive oxygen species (ROS)-induced endothelial apoptosis by up-regulating inflammation response and oxidative stress. Locally administering metformin on vein grafts through 3D-printed external stent (PGS-PCL) shows antioxidative and anti-inflammatory properties to protect cells from ROS invasion, thereafter decreasing acute thrombosis. Moreover, metformin induce rapid regeneration of perivascular adipose tissue in recipient regions, which improves patency by inhibiting intimal hyperplasia. Proteomics, western blot, and in vitro blocking tests reveal that metformin resists endothelial apoptosis through AMPK/mTOR and NFκB signaling pathways. To conclude, PVT deprivation exacerbates inflammatory response and oxidative stress in vein grafts bridging arterial circulation. Metformin-loaded stent ameliorates "PVT damage" related vein graft failure, and enhances patency of through resisting endothelial apoptosis and regenerating arterial PVAT, offering a promising avenue to improve the success of vein grafts in clinic.
Collapse
Affiliation(s)
- Yinggang Wang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Mingdi Fu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Weiwei Xiao
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Yajing Zhao
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Pingping Yuan
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Xinchi Zhang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Wei Wu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| |
Collapse
|
5
|
Gemelli M, Gallo M, Addonizio M, Pahwa S, Van den Eynde J, Trivedi J, Slaughter MS, Gerosa G. Venous External Support in Coronary Artery Bypass Surgery: A Systematic Review and Meta-Analysis. Curr Probl Cardiol 2023; 48:101687. [PMID: 36931334 DOI: 10.1016/j.cpcardiol.2023.101687] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 03/02/2023] [Indexed: 03/17/2023]
Abstract
OBJECTIVES Neointimal hyperplasia and lumen irregularities are major contributors to vein graft failure and the use of VEST(R) should prevent this. In this review, we aim to evaluate the angiographic outcomes of externally supported vein grafts. METHODS Medline, Embase and Cochrane Library were systematically reviewed for randomized clinical trials published by August 2022. The primary outcome was graft failure. Secondary outcomes included graft ectasia, intimal hyperplasia area and thickness, and graft non-uniformity. Odds ratios (OR) for dichotomous variables and mean difference (MD) for continuous variables with 95% confidence intervals (CI) were pooled using a fixed-effects model. RESULTS Three randomized controlled trials with a total of 437 patients were included with follow-up ranging from 1 to 2 years. The odds of graft failure were similar in the two groups (OR 1.22; 95%CI 0.88 to 1.71; I²=0%). Intimal hyperplasia area [MD -0.77 mm2; 95%CI -1.10 to -0.45; I2=0%] and thickness [MD -0.06 mm; 95%CI -0.08 to -0.04; I2=0%] were significantly lower in the VEST group. Fitzgibbon Patency Scale of II or III (representing angiographic conduit non-uniformity; OR 0.67; 95%CI 0.48 to 0.94; I2=0%) and graft ectasia (OR 0.53; 95%CI 0.32 to 0.88; I2=33%) were also significantly lower in the VEST group. CONCLUSIONS At short-term follow-up, VEST does not seem to reduce the incidence of graft failure, although it is associated with attenuation of intimal hyperplasia and non-uniformity. Longer angiographic follow-up is warranted to determine whether these positive effects might translate into a positive effect in graft failure and in long-term clinical outcomes.
Collapse
Affiliation(s)
- Marco Gemelli
- Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Italy
| | - Michele Gallo
- Department of Cardiothoracic Surgery, University of Louisville, Louisville, Kentucky, USA.
| | - Mariangela Addonizio
- Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Italy
| | - Siddharth Pahwa
- Department of Cardiothoracic Surgery, University of Louisville, Louisville, Kentucky, USA
| | | | - Jaimin Trivedi
- Department of Cardiothoracic Surgery, University of Louisville, Louisville, Kentucky, USA
| | - Mark S Slaughter
- Department of Cardiothoracic Surgery, University of Louisville, Louisville, Kentucky, USA
| | - Gino Gerosa
- Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Italy
| |
Collapse
|
6
|
Dimagli A, Soletti G, Harik L, Perezgrovas Olaria R, Cancelli G, An KR, Alzghari T, Mack C, Gaudino M. Angiographic Outcomes for Arterial and Venous Conduits Used in CABG. J Clin Med 2023; 12:2022. [PMID: 36902809 PMCID: PMC10004690 DOI: 10.3390/jcm12052022] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 02/25/2023] [Accepted: 03/02/2023] [Indexed: 03/08/2023] Open
Abstract
Coronary artery bypass grafting is the most commonly performed cardiac surgical procedure. Conduit selection is crucial to achieving early optimal outcomes, with graft patency being likely the main driver to long-term survival. We present a review of current evidence on the patency of arterial and venous bypass conduits and of differences in angiographic outcomes.
Collapse
Affiliation(s)
- Arnaldo Dimagli
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, NY 10065, USA
| | - Giovanni Soletti
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, NY 10065, USA
| | - Lamia Harik
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, NY 10065, USA
| | | | - Gianmarco Cancelli
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, NY 10065, USA
| | - Kevin R. An
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, NY 10065, USA
| | - Talal Alzghari
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, NY 10065, USA
| | - Charles Mack
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, NY 10065, USA
- Department of Cardiothoracic Surgery, New York Presbyterian Queens Hospital, Queens, New York, NY 11355, USA
| | - Mario Gaudino
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, NY 10065, USA
| |
Collapse
|
7
|
Biodegradable external wrapping promotes favorable adaptation in an ovine vein graft model. Acta Biomater 2022; 151:414-425. [PMID: 35995404 DOI: 10.1016/j.actbio.2022.08.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 08/09/2022] [Accepted: 08/15/2022] [Indexed: 11/23/2022]
Abstract
Vein grafts, the most commonly used conduits in multi-vessel coronary artery bypass grafting surgery, have high intermediate- and long-term failure rates. The abrupt and marked increase in hemodynamic loads on the vein graft is a known contributor to failure. Recent computational modeling suggests that veins can more successfully adapt to an increase in mechanical load if the rate of loading is gradual. Applying an external wrap or support at the time of surgery is one way to reduce the transmural load, and this approach has improved performance relative to an unsupported vein graft in several animal studies. Yet, a clinical trial in humans has shown benefits and drawbacks, and mechanisms by which an external wrap affects vein graft adaptation remain unknown. This study aims to elucidate such mechanisms using a multimodal experimental and computational data collection pipeline. We quantify morphometry using magnetic resonance imaging, mechanics using biaxial testing, hemodynamics using computational fluid dynamics, structure using histology, and transcriptional changes using bulk RNA-sequencing in an ovine carotid-jugular interposition vein graft model, without and with an external biodegradable wrap that allows loads to increase gradually. We show that a biodegradable external wrap promotes luminal uniformity, physiological wall shear stress, and a consistent vein graft phenotype, namely, it prevents over-distension, over-thickening, intimal hyperplasia, and inflammation, and it preserves mechanotransduction. These mechanobiological insights into vein graft adaptation in the presence of an external support can inform computational growth and remodeling models of external support and facilitate design and manufacturing of next-generation external wrapping devices. STATEMENT OF SIGNIFICANCE: External mechanical support is emerging as a promising technology to prevent vein graft failure following coronary bypass graft surgery. While variants of this technology are currently under investigation in clinical trials, the fundamental mechanisms of adaptation remain poorly understood. We employ an ovine carotid-jugular interposition vein graft model, with and without an external biodegradable wrap to provide mechanical support, and probe vein graft adaptation using a multimodal experimental and computational data collection pipeline. We quantify morphometry using magnetic resonance imaging, mechanics using biaxial testing, fluid flow using computational fluid dynamics, vascular composition and structure using histology, and transcriptional changes using bulk RNA sequencing. We show that the wrap mitigates vein graft failure by promoting multiple adaptive mechanisms (across biological scales).
Collapse
|
8
|
Nakamura M, Yaku H, Ako J, Arai H, Asai T, Chikamori T, Daida H, Doi K, Fukui T, Ito T, Kadota K, Kobayashi J, Komiya T, Kozuma K, Nakagawa Y, Nakao K, Niinami H, Ohno T, Ozaki Y, Sata M, Takanashi S, Takemura H, Ueno T, Yasuda S, Yokoyama H, Fujita T, Kasai T, Kohsaka S, Kubo T, Manabe S, Matsumoto N, Miyagawa S, Mizuno T, Motomura N, Numata S, Nakajima H, Oda H, Otake H, Otsuka F, Sasaki KI, Shimada K, Shimokawa T, Shinke T, Suzuki T, Takahashi M, Tanaka N, Tsuneyoshi H, Tojo T, Une D, Wakasa S, Yamaguchi K, Akasaka T, Hirayama A, Kimura K, Kimura T, Matsui Y, Miyazaki S, Okamura Y, Ono M, Shiomi H, Tanemoto K. JCS 2018 Guideline on Revascularization of Stable Coronary Artery Disease. Circ J 2022; 86:477-588. [DOI: 10.1253/circj.cj-20-1282] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Masato Nakamura
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center
| | - Hitoshi Yaku
- Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine
| | - Junya Ako
- Department of Cardiovascular Medicine, Kitasato University Graduate School of Medical Sciences
| | - Hirokuni Arai
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Tohru Asai
- Department of Cardiovascular Surgery, Juntendo University Graduate School of Medicine
| | | | - Hiroyuki Daida
- Department of Cardiovascular Medicine, Juntendo University Graduate School of Medicine
| | - Kiyoshi Doi
- General and Cardiothoracic Surgery, Gifu University Graduate School of Medicine
| | - Toshihiro Fukui
- Department of Cardiovascular Surgery, Graduate School of Medical Sciences, Kumamoto University
| | - Toshiaki Ito
- Department of Cardiovascular Surgery, Japanese Red Cross Nagoya Daiichi Hospital
| | | | - Junjiro Kobayashi
- Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center
| | - Tatsuhiko Komiya
- Department of Cardiovascular Surgery, Kurashiki Central Hospital
| | - Ken Kozuma
- Department of Internal Medicine, Teikyo University Faculty of Medicine
| | - Yoshihisa Nakagawa
- Department of Cardiovascular Medicine, Shiga University of Medical Science
| | - Koichi Nakao
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center
| | - Hiroshi Niinami
- Department of Cardiovascular Surgery, Tokyo Women’s Medical University
| | - Takayuki Ohno
- Department of Cardiovascular Surgery, Mitsui Memorial Hospital
| | - Yukio Ozaki
- Department of Cardiology, Fujita Health University Hospital
| | - Masataka Sata
- Department of Cardiovascular Medicine, Tokushima University Graduate School of Biomedical Sciences
| | | | - Hirofumi Takemura
- Department of Cardiovascular Surgery, Graduate School of Medical Sciences, Kanazawa University
| | | | - Satoshi Yasuda
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center
| | - Hitoshi Yokoyama
- Department of Cardiovascular Surgery, Fukushima Medical University
| | - Tomoyuki Fujita
- Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center
| | - Tokuo Kasai
- Department of Cardiology, Uonuma Institute of Community Medicine, Niigata University Uonuma Kikan Hospital
| | - Shun Kohsaka
- Department of Cardiology, Keio University School of Medicine
| | - Takashi Kubo
- Department of Cardiovascular Medicine, Wakayama Medical University
| | - Susumu Manabe
- Department of Cardiovascular Surgery, Tsuchiura Kyodo General Hospital
| | | | - Shigeru Miyagawa
- Frontier of Regenerative Medicine, Graduate School of Medicine, Osaka University
| | - Tomohiro Mizuno
- Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Noboru Motomura
- Department of Cardiovascular Surgery, Graduate School of Medicine, Toho University
| | - Satoshi Numata
- Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine
| | - Hiroyuki Nakajima
- Department of Cardiovascular Surgery, Saitama Medical University International Medical Center
| | - Hirotaka Oda
- Department of Cardiology, Niigata City General Hospital
| | - Hiromasa Otake
- Department of Cardiovascular Medicine, Kobe University Graduate School of Medicine
| | - Fumiyuki Otsuka
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center
| | - Ken-ichiro Sasaki
- Division of Cardiovascular Medicine, Kurume University School of Medicine
| | - Kazunori Shimada
- Department of Cardiovascular Medicine, Juntendo University Graduate School of Medicine
| | - Tomoki Shimokawa
- Department of Cardiovascular Surgery, Sakakibara Heart Institute
| | - Toshiro Shinke
- Division of Cardiology, Department of Medicine, Showa University School of Medicine
| | - Tomoaki Suzuki
- Department of Cardiovascular Surgery, Shiga University of Medical Science
| | - Masao Takahashi
- Department of Cardiovascular Surgery, Hiratsuka Kyosai Hospital
| | - Nobuhiro Tanaka
- Department of Cardiology, Tokyo Medical University Hachioji Medical Center
| | | | - Taiki Tojo
- Department of Cardiovascular Medicine, Kitasato University Graduate School of Medical Sciences
| | - Dai Une
- Department of Cardiovascular Surgery, Okayama Medical Center
| | - Satoru Wakasa
- Department of Cardiovascular and Thoracic Surgery, Hokkaido University Graduate School of Medicine
| | - Koji Yamaguchi
- Department of Cardiovascular Medicine, Tokushima University Graduate School of Biomedical Sciences
| | - Takashi Akasaka
- Department of Cardiovascular Medicine, Wakayama Medical University
| | | | - Kazuo Kimura
- Cardiovascular Center, Yokohama City University Medical Center
| | - Takeshi Kimura
- Department of Cardiovascular Medicine, Graduate School of Medicine, Kyoto University
| | - Yoshiro Matsui
- Department of Cardiovascular and Thoracic Surgery, Graduate School of Medicine, Hokkaido University
| | - Shunichi Miyazaki
- Division of Cardiology, Department of Internal Medicine, Faculty of Medicine, Kindai University
| | | | - Minoru Ono
- Department of Cardiac Surgery, Graduate School of Medicine, The University of Tokyo
| | - Hiroki Shiomi
- Department of Cardiovascular Medicine, Graduate School of Medicine, Kyoto University
| | - Kazuo Tanemoto
- Department of Cardiovascular Surgery, Kawasaki Medical School
| | | |
Collapse
|
9
|
Goldstein DJ. Device Profile of the VEST for External Support of SVG Coronary Artery Bypass Grafting: Historical Development, Current Status and Future Directions. Expert Rev Med Devices 2021; 18:921-931. [PMID: 34311644 DOI: 10.1080/17434440.2021.1960504] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
A search for strategies to address saphenous vein graft (SVG) failure - the main factor limiting the long-term success of coronary bypass grafting - has led to trialing of external stenting technologies. AREAS COVERED The manuscript covers historical development and current status of external scaffolding for the treatment of SVG intimal hyperplasia. Comprehensive literature review and personal communication with VGS leadership, the developer of the VEST device, served as the sources. EXPERT OPINION If the external scaffolding concept proves to be successful in mitigating the intimal hyperplasia inherent to arterialized saphenous vein conduits, it could have a dramatic impact on the recurrence of anginal symptoms, the need for repeat revascularization, and the incidence of myocardial infarction following CABG surgery. These laudable sequelae could ultimately convey significant public health repercussions by reducing healthcare resource use and improving the long-term survival and quality of life of CABG recipients.
Collapse
Affiliation(s)
- Daniel J Goldstein
- Montefiore Medical Center - Cardiothoracic Surgery, Bainbridge Ave MAP Building, 5th Fl Bronx, New York, USA
| |
Collapse
|
10
|
Taggart DP, Gavrilov Y, Krasopoulos G, Rajakaruna C, Zacharias J, De Silva R, Channon KM, Gehrig T, Donovan TJ, Friedrich I. External stenting and disease progression in saphenous vein grafts two years after coronary artery bypass grafting: A multicenter randomized trial. J Thorac Cardiovasc Surg 2021; 164:1532-1541.e2. [PMID: 34024615 DOI: 10.1016/j.jtcvs.2021.03.120] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 03/28/2021] [Accepted: 03/29/2021] [Indexed: 11/16/2022]
Abstract
OBJECTIVES Little data exist regarding the potential of external stents to mitigate long-term disease progression in saphenous vein grafts. We investigated the effect of external stents on the progression of saphenous vein graft disease. METHODS A total of 184 patients undergoing isolated coronary artery bypass grafting, using an internal thoracic artery graft and at least 2 additional saphenous vein grafts, were enrolled in 14 European centers. One saphenous vein graft was randomized to an external stent, and 1 nonstented saphenous vein graft served as the control. The primary end point was the saphenous vein graft Fitzgibbon patency scale assessed by angiography, and the secondary end point was saphenous vein graft intimal hyperplasia assessed by intravascular ultrasound in a prespecified subgroup at 2 years. RESULTS Angiography was completed in 128 patients and intravascular ultrasound in the entire prespecified cohort (n = 51) at 2 years. Overall patency rates were similar between stented and nonstented saphenous vein grafts (78.3% vs 82.2%, P = .43). However, the Fitzgibbon patency scale was significantly improved in stented versus nonstented saphenous vein grafts, with Fitzgibbon patency scale I, II, and III rates of 66.7% versus 54.9%, 27.8% versus 34.3%, and 5.5% versus 10.8%, respectively (odds ratio, 2.02; P = .03). Fitzgibbon patency scale was inversely related to saphenous vein graft minimal lumen diameter, with Fitzgibbon patency scale I, II, and III saphenous vein grafts having an average minimal lumen diameter of 2.62 mm, 1.98 mm, and 1.32 mm, respectively (P < .05). Externally stented saphenous vein grafts also showed significant reductions in mean intimal hyperplasia area (22.5%; P < .001) and thickness (23.5%; P < .001). CONCLUSIONS Two years after coronary artery bypass grafting, external stenting improves Fitzgibbon patency scales of saphenous vein grafts and significantly reduces intimal hyperplasia area and thickness. Whether this will eventually lead to improved long-term patency is still unknown.
Collapse
Affiliation(s)
- David P Taggart
- Nuffield Department of Surgical Sciences, University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
| | | | - George Krasopoulos
- Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
| | - Cha Rajakaruna
- Department of Cardiothoracic Surgery, University Hospitals Bristol, Bristol, United Kingdom
| | - Joseph Zacharias
- Department of Cardiothoracic Surgery, Blackpool Victoria Hospital, Blackpool, United Kingdom
| | - Ravi De Silva
- Department of Cardiothoracic Surgery, Papworth Hospital, Cambridge, United Kingdom
| | - Keith M Channon
- Department of Cardiovascular Medicine, University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
| | - Thomas Gehrig
- Herzzentrum Trier, Krankenhaus der Barmherzigen Bruder, Trier, Germany
| | | | - Ivar Friedrich
- Herzzentrum Trier, Krankenhaus der Barmherzigen Bruder, Trier, Germany.
| | | |
Collapse
|
11
|
Angelini GD, Johnson T, Culliford L, Murphy G, Ashton K, Harris T, Edwards J, Clayton G, Kim Y, Newby AC, Reeves BC, Rogers CA. Comparison of alternate preparative techniques on wall thickness in coronary artery bypass grafts: The HArVeST randomized controlled trial. J Card Surg 2021; 36:1985-1995. [PMID: 33710658 DOI: 10.1111/jocs.15477] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 01/21/2021] [Accepted: 01/22/2021] [Indexed: 12/21/2022]
Abstract
BACKGROUND The success of coronary artery bypass grafting surgery (CABG) is dependent on long-term graft patency, which is negatively related to early wall thickening. Avoiding high-pressure distension testing for leaks and preserving the surrounding pedicle of fat and adventitia during vein harvesting may reduce wall thickening. METHODS A single-centre, factorial randomized controlled trial was carried out to compare the impact of testing for leaks under high versus low pressure and harvesting the vein with versus without the pedicle in patients undergoing CABG. The primary outcomes were graft wall thickness, as indicator of medial-intimal hyperplasia, and lumen diameter assessed using intravascular ultrasound after 12 months. RESULTS Ninety-six eligible participants were recruited. With conventional harvest, low-pressure testing tended to yield a thinner vessel wall compared with high-pressure (mean difference [MD; low minus high] -0.059 mm, 95% confidence interval (CI) -0.12, +0.0039, p = .066). With high pressure testing, veins harvested with the pedicle fat tended to have a thinner vessel wall than those harvested conventionally (MD [pedicle minus conventional] -0.057 mm, 95% CI: -0.12, +0.0037, p = .066, test for interaction p = .07). Lumen diameter was similar across groups (harvest comparison p = .81; pressure comparison p = .24). Low-pressure testing was associated with fewer hospital admissions in the 12 months following surgery (p = .0008). Harvesting the vein with the pedicle fat was associated with more complications during the index admission (p = .0041). CONCLUSIONS Conventional saphenous vein graft preparation with low-pressure distension and harvesting the vein with a surrounding pedicle yielded similar graft wall thickness after 12 months, but low pressure was associated with fewer adverse events.
Collapse
Affiliation(s)
| | - Tom Johnson
- Bristol Heart Institute, University of Bristol, Bristol, UK
| | - Lucy Culliford
- Clinical Trials and Evaluation Unit, Bristol Trials Centre, University of Bristol, Bristol, UK
| | - Gavin Murphy
- MRC Integrative Epidemiology Unit, University of Bristol, Bristol, UK
| | - Kate Ashton
- Clinical Trials and Evaluation Unit, Bristol Trials Centre, University of Bristol, Bristol, UK
| | - Tracy Harris
- Clinical Trials and Evaluation Unit, Bristol Trials Centre, University of Bristol, Bristol, UK
| | - Julia Edwards
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK
| | - Gemma Clayton
- School of Health and Related Research, University of Sheffield, Sheffield, UK
| | - Yongcheol Kim
- Yongin Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Andrew C Newby
- Bristol Heart Institute, University of Bristol, Bristol, UK
| | - Barney C Reeves
- Clinical Trials and Evaluation Unit, Bristol Trials Centre, University of Bristol, Bristol, UK
| | - Chris A Rogers
- Clinical Trials and Evaluation Unit, Bristol Trials Centre, University of Bristol, Bristol, UK
| |
Collapse
|
12
|
Samano N, Souza D, Dashwood MR. Saphenous veins in coronary artery bypass grafting need external support. Asian Cardiovasc Thorac Ann 2020; 29:457-467. [PMID: 33307718 PMCID: PMC8167919 DOI: 10.1177/0218492320980936] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
The saphenous vein is the most commonly used conduit for coronary artery bypass grafting. Arterial grafts are harvested with the outer pedicle intact whereas saphenous veins are harvested with the pedicle removed in the conventional graft harvesting technique. This conventional procedure causes considerable vascular damage. One strategy to improve vein graft patency has been to provide external support. Ongoing studies show that fitting a metal external support improves conventionally harvested saphenous vein graft patency. On the other hand, the no-touch technique of harvesting the saphenous vein provides an improved graft with long-term patency comparable to that of the internal mammary artery. This improvement is suggested to be due to preservation of vessel structures. Interestingly, many of the mechanisms proposed to be associated with the beneficial actions of an artificial external support on saphenous vein graft patency are similar to those underlying the beneficial effect of no-touch saphenous vein grafts where the intact outer layer acts as a natural support. Additional actions of external supports have been advocated, including promotion of angiogenesis, increased production of vascular-protective factors, and protection of endothelial cells. Using no-touch harvesting, normal vascular architecture is maintained, tissue and cell damage is minimized, and factors beneficial for graft patency are preserved. In this review, the significance of external support of saphenous vein grafts in coronary artery bypass grafting is discussed.
Collapse
Affiliation(s)
- Ninos Samano
- Department of Cardiothoracic and Vascular Surgery and University Health Care Research Center, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
| | - Domingos Souza
- Department of Cardiothoracic and Vascular Surgery and University Health Care Research Center, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
| | - Michael R Dashwood
- Surgical and Interventional Sciences, Royal Free Hospital Campus, University College Medical School, London, UK
| |
Collapse
|
13
|
Ramachandra AB, Latorre M, Szafron JM, Marsden AL, Humphrey JD. Vascular adaptation in the presence of external support - A modeling study. J Mech Behav Biomed Mater 2020; 110:103943. [PMID: 32957235 DOI: 10.1016/j.jmbbm.2020.103943] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 04/24/2020] [Accepted: 06/17/2020] [Indexed: 10/24/2022]
Abstract
Vascular grafts have long been used to replace damaged or diseased vessels with considerable success, but a new approach is emerging where native vessels are merely supported, not replaced. Although external supports have been evaluated in diverse situations - ranging from aneurysmal disease to vein grafts or the Ross operation - optimal supports and procedures remain wanting. In this paper, we present a novel application of a growth and remodeling model well suited for parametrically exploring multiple designs of external supports while accounting for mechanobiological and immunobiological responses of the supported native vessel. These results suggest that a load bearing external support can reduce vessel thickening in response to pressure elevation. Results also suggest that the final adaptive state of the vessel depends on the structural stiffness of the support via a mechano-driven adaptation, although luminal encroachment may be a complication in the presence of chronic inflammation. Finally, the supported vessel can stiffen (structurally and materially) along circumferential and axial directions, which could have implications on overall hemodynamics and thus subsequent vascular remodeling. The proposed framework can provide valuable insights into vascular adaptation in the presence of external support, accelerate rational design, and aid translation of this emerging approach.
Collapse
Affiliation(s)
| | - Marcos Latorre
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Jason M Szafron
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Alison L Marsden
- Departments of Bioengineering and Pediatrics, Institute of Computational and Mathematical Engineering, Stanford University, Stanford, CA, USA
| | - Jay D Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA; Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT, USA.
| |
Collapse
|
14
|
Yang Q, Lei D, Huang S, Yang Y, Jiang C, Shi H, Chen W, Zhao Q, You Z, Ye X. A novel biodegradable external stent regulates vein graft remodeling via the Hippo-YAP and mTOR signaling pathways. Biomaterials 2020; 258:120254. [PMID: 32805499 DOI: 10.1016/j.biomaterials.2020.120254] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2020] [Revised: 07/15/2020] [Accepted: 07/20/2020] [Indexed: 01/10/2023]
Abstract
Coronary artery bypass graft (CABG) has been confirmed to effectively improve the prognosis of coronary artery disease, which is a major public health concern worldwide. As the most frequently used conduits in CABG, saphenous vein grafts have the disadvantage of being susceptible to restenosis due to intimal hyperplasia. To meet the urgent clinical demand, adopting external stents (eStents) and illuminating the potential mechanisms underlying their function are important for preventing vein graft failure. Here, using 4-axis printing technology, we fabricated a novel biodegradable and flexible braided eStent, which exerts excellent inhibitory effect on intimal hyperplasia. The stented grafts downregulate Yes-associated protein (YAP), indicating that the eStent regulates vein graft remodeling via the Hippo-YAP signaling pathway. Further, as a drug-delivery vehicle, a rapamycin (RM)-coated eStent was designed to amplify the inhibitory effect of eStent on intimal hyperplasia through the synergistic effects of the Hippo and mammalian target of rapamycin (mTOR) signaling pathways. Overall, this study uncovers the underlying mechanisms of eStent function and identifies a new therapeutic target for the prevention of vein graft restenosis.
Collapse
Affiliation(s)
- Qi Yang
- Department of Cardiovascular Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200025, China
| | - Dong Lei
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Belt and Road Joint Laboratory of Advanced Fiber and Low-dimension Materials (Donghua University), College of Materials Science and Engineering, Donghua University, Shanghai, 201620, China
| | - Shixing Huang
- Department of Cardiovascular Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200025, China
| | - Yang Yang
- Department of Cardiothoracic Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200092, China
| | - Chenyu Jiang
- Department of Cardiovascular Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200025, China
| | - Hongpeng Shi
- Department of Cardiovascular Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200025, China
| | - Wenyi Chen
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Belt and Road Joint Laboratory of Advanced Fiber and Low-dimension Materials (Donghua University), College of Materials Science and Engineering, Donghua University, Shanghai, 201620, China
| | - Qiang Zhao
- Department of Cardiovascular Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200025, China.
| | - Zhengwei You
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Belt and Road Joint Laboratory of Advanced Fiber and Low-dimension Materials (Donghua University), College of Materials Science and Engineering, Donghua University, Shanghai, 201620, China.
| | - Xiaofeng Ye
- Department of Cardiovascular Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200025, China.
| |
Collapse
|
15
|
Samano N, Souza D, Pinheiro BB, Kopjar T, Dashwood M. Twenty-Five Years of No-Touch Saphenous Vein Harvesting for Coronary Artery Bypass Grafting: Structural Observations and Impact on Graft Performance. Braz J Cardiovasc Surg 2020; 35:91-99. [PMID: 32270965 PMCID: PMC7089755 DOI: 10.21470/1678-9741-2019-0238] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
The saphenous vein is the most common conduit used in coronary artery bypass grafting (CABG) yet its failure rate is higher compared to arterial grafts. An improvement in saphenous vein graft performance is therefore a major priority in CABG. No-touch harvesting of the saphenous vein is one of the few interventions that has shown improved patency rates, comparable to that of the left internal thoracic artery. After more than two decades of no-touch research, this technique is now recognized as a Class IIa recommendation in the 2018 European Society of Cardiology and the European Association for Cardio-Thoracic Surgery guidelines on myocardial revascularization. In this review, we describe the structural alterations that occur in conventional versus no-touch saphenous vein grafts and how these changes affect graft patency. In addition, we discuss various strategies aimed at repairing saphenous vein grafts prepared at conventional CABG.
Collapse
Affiliation(s)
- Ninos Samano
- Örebro University Faculty of Medicine and Health Örebro Sweden Department of Cardiothoracic and Vascular Surgery and University Health Care Research Center, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
| | - Domingos Souza
- Örebro University Faculty of Medicine and Health Department of Cardiothoracic and Vascular Surgery Örebro Sweden Department of Cardiothoracic and Vascular Surgery, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
| | - Bruno Botelho Pinheiro
- Hospital do Coração Anis Rassi Department Cardiovascular Surgery Goiânia GO Brazil Department Cardiovascular Surgery, Hospital do Coração Anis Rassi, Goiânia, GO, Brazil
| | - Tomislav Kopjar
- University Hospital Centre Zagreb University of Zagreb School of Medicine Department of Cardiac Surgery Zagreb Croatia Department of Cardiac Surgery, University of Zagreb School of Medicine and University Hospital Centre Zagreb, Zagreb, Croatia
| | - Michael Dashwood
- University College London Medical School Royal Free Hospital Campus Surgical and Interventional Sciences London UK Surgical and Interventional Sciences, Royal Free Hospital Campus, University College London Medical School, London, UK
| |
Collapse
|
16
|
Yang Q, Lei D, Huang S, Yang Y, Yang Y, Ye X, You Z, Zhao Q. Effects of the different-sized external stents on vein graft intimal hyperplasia and inflammation. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:102. [PMID: 32175395 DOI: 10.21037/atm.2020.01.16] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Background The poor long-term patency ratio of vein grafts prevents patients from benefiting from coronary artery bypass graft (CABG). It is reported that external venous stents have notably improved the patency ratio of stented vein grafts in animal models. The most crucial influence on stented grafts' fate is the size of the stents. This study aims to investigate the effects on intimal hyperplasia and inflammation of vein graft by using different sizes of stents and explore the potential mechanism. Methods Two different sizes of external stents were fabricated through 3D printing technology. Male SD rats were divided into three groups. In the control group rat's autologous left jugular vein was grafted on the ipsilateral artery directly. In the stent groups, grafts were surrounded by two different-sized stents before anastomosing with arteries. The patency ratio and diameter of the grafts were examined by ultrasound. Masson staining was used to characterize intimal hyperplasia. The expression of inflammatory factors was detected by immunohistochemical staining. Moreover, TUNEL staining was used to label apoptotic cells. Results The two sizes of external stents were fabricated by 3D printing technology. In the control group, the intima area and wall thickness dramatically increased 8 weeks after implantation. While in the stent groups, these data only slightly increased, especially in the 1.5 mm-stent group. The expressions of inflammatory factors in TNF signaling were more remarkable than in the control group. On the contrary, the expressions were rarely detected in the stent groups. Similarly, the number of TUNEL positive cells dramatically decreased by using the appropriate-sized stent. Conclusions In this study, we concluded that the appropriate sizes of external stents could effectively inhibit vein graft neointima formation, attenuate inflammatory reaction and reduce cell apoptosis, which might improve the long-term patency ratio of vein grafts.
Collapse
Affiliation(s)
- Qi Yang
- Department of Cardiac Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China
| | - Dong Lei
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Belt and Road Joint Laboratory of Advanced Fiber and Low-dimension Materials (Donghua University), College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Shixing Huang
- Department of Cardiac Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China
| | - Yi Yang
- Department of Cardiac Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China
| | - Yang Yang
- Department of Cardiothoracic Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200092, China
| | - Xiaofeng Ye
- Department of Cardiac Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China
| | - Zhengwei You
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Belt and Road Joint Laboratory of Advanced Fiber and Low-dimension Materials (Donghua University), College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Qiang Zhao
- Department of Cardiac Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China
| |
Collapse
|
17
|
Wadey K, Lopes J, Bendeck M, George S. Role of smooth muscle cells in coronary artery bypass grafting failure. Cardiovasc Res 2019; 114:601-610. [PMID: 29373656 DOI: 10.1093/cvr/cvy021] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Accepted: 01/22/2018] [Indexed: 01/30/2023] Open
Abstract
Atherosclerosis is the underlying pathology of many cardiovascular diseases. The formation and rupture of atherosclerotic plaques in the coronary arteries results in angina and myocardial infarction. Venous coronary artery bypass grafts are designed to reduce the consequences of atherosclerosis in the coronary arteries by diverting blood flow around the atherosclerotic plaques. However, vein grafts suffer a high failure rate due to intimal thickening that occurs as a result of vascular cell injury and activation and can act as 'a soil' for subsequent atherosclerotic plaque formation. A clinically-proven method for the reduction of vein graft intimal thickening and subsequent major adverse clinical events is currently not available. Consequently, a greater understanding of the underlying mechanisms of intimal thickening may be beneficial for the design of future therapies for vein graft failure. Vein grafting induces inflammation and endothelial cell damage and dysfunction, that promotes vascular smooth muscle cell (VSMC) migration, and proliferation. Injury to the wall of the vein as a result of grafting leads to the production of chemoattractants, remodelling of the extracellular matrix and cell-cell contacts; which all contribute to the induction of VSMC migration and proliferation. This review focuses on the role of altered behaviour of VSMCs in the vein graft and some of the factors which critically lead to intimal thickening that pre-disposes the vein graft to further atherosclerosis and re-occurrence of symptoms in the patient.
Collapse
Affiliation(s)
- Kerry Wadey
- Bristol Medical School, Research Floor Level 7, Bristol Royal Infirmary, Bristol BS2 8HW, UK
| | - Joshua Lopes
- Translational Biology and Engineering Program, University of Toronto, Toronto, ON M5G 1M1, Canada
| | - Michelle Bendeck
- Translational Biology and Engineering Program, University of Toronto, Toronto, ON M5G 1M1, Canada
| | - Sarah George
- Bristol Medical School, Research Floor Level 7, Bristol Royal Infirmary, Bristol BS2 8HW, UK
| |
Collapse
|
18
|
Gooch KJ, Firstenberg MS, Shrefler BS, Scandling BW. Biomechanics and Mechanobiology of Saphenous Vein Grafts. J Biomech Eng 2019; 140:2666246. [PMID: 29222565 DOI: 10.1115/1.4038705] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2017] [Indexed: 11/08/2022]
Abstract
Within several weeks of use as coronary artery bypass grafts (CABG), saphenous veins (SV) exhibit significant intimal hyperplasia (IH). IH predisposes vessels to thrombosis and atherosclerosis, the two major modes of vein graft failure. The fact that SV do not develop significant IH in their native venous environment coupled with the rapidity with which they develop IH following grafting into the arterial circulation suggests that factors associated with the isolation and preparation of SV and/or differences between the venous and arterial environments contribute to disease progression. There is strong evidence suggesting that mechanical trauma associated with traditional techniques of SV preparation can significantly damage the vessel and might potentially reduce graft patency though modern surgical techniques reduces these injuries. In contrast, it seems possible that modern surgical technique, specifically endoscopic vein harvest, might introduce other mechanical trauma that could subtly injure the vein and perhaps contribute to the reduced patency observed in veins harvested using endoscopic techniques. Aspects of the arterial mechanical environment influence remodeling of SV grafted into the arterial circulation. Increased pressure likely leads to thickening of the medial wall but its role in IH is less clear. Changes in fluid flow, including increased average wall shear stress, may reduce IH while disturbed flow likely increase IH. Nonmechanical stimuli, such as exposure to arterial levels of oxygen, may also have a significant but not widely recognized role in IH. Several potentially promising approaches to alter the mechanical environment to improve graft patency are including extravascular supports or altered graft geometries are covered.
Collapse
Affiliation(s)
- Keith J Gooch
- Department of Biomedical Engineering, The Ohio State University, 290 Bevis Hall 1080 Carmack Drive, Columbus, OH 43210.,Davis Heart Lung Research Institute, The Ohio State University, Columbus, OH 43210 e-mail:
| | - Michael S Firstenberg
- Surgery and Integrative Medicine, Northeast Ohio Medical Universities, Akron, OH 44309
| | - Brittany S Shrefler
- Department of Internal Medicine, The Ohio State University, Columbus, OH 43210
| | - Benjamin W Scandling
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH 43210
| |
Collapse
|
19
|
Mawhinney JA, Mounsey CA, Taggart DP. Reply to Dashwood. Eur J Cardiothorac Surg 2019; 55:1022. [PMID: 30535071 DOI: 10.1093/ejcts/ezy413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2018] [Accepted: 11/08/2018] [Indexed: 11/13/2022] Open
Affiliation(s)
- Jamie A Mawhinney
- Cardiovascular Division, Academic Department of Vascular Surgery, St Thomas' Hospital, London, UK
| | | | - David P Taggart
- Department of Cardiothoracic Surgery, Oxford University Hospitals NHS Trust, Oxford, UK
| |
Collapse
|
20
|
Dashwood MR. Why 'EXTENT' for coronary artery bypass surgery when the saphenous vein should need no support? Eur J Cardiothorac Surg 2019; 55:1021. [PMID: 30534985 DOI: 10.1093/ejcts/ezy412] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Accepted: 11/06/2018] [Indexed: 11/13/2022] Open
Affiliation(s)
- Michael R Dashwood
- Division of Surgery and Interventional Science, University College London Medical School, London, UK
| |
Collapse
|
21
|
Yasuda S, Goda M, Shibuya T, Uchida K, Suzuki S, Noishiki Y, Yokoyama U, Ishikawa Y, Masuda M. An appropriately sized soft polyester external stent prevents enlargement and neointimal hyperplasia of a saphenous vein graft in a canine model. Artif Organs 2019; 43:577-583. [DOI: 10.1111/aor.13399] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Revised: 11/06/2018] [Accepted: 11/20/2018] [Indexed: 12/21/2022]
Affiliation(s)
- Shota Yasuda
- Department of Surgery Yokohama City University Yokohama Japan
| | - Motohiko Goda
- Department of Surgery Yokohama City University Yokohama Japan
| | - Taisuke Shibuya
- Department of Surgery Yokohama City University Yokohama Japan
| | - Keiji Uchida
- Cardiovascular Center Yokohama City University Medical Center Yokohama Japan
| | - Shinichi Suzuki
- Department of Surgery Yokohama City University Yokohama Japan
| | - Yasuharu Noishiki
- Department of Neurological Anatomy Yokohama City University Yokohama Japan
| | - Utako Yokoyama
- Cardiovascular Research Institute Yokohama City University Yokohama Japan
| | - Yoshihiro Ishikawa
- Cardiovascular Research Institute Yokohama City University Yokohama Japan
| | - Munetaka Masuda
- Department of Surgery Yokohama City University Yokohama Japan
| |
Collapse
|
22
|
Saphenous vein: advances. Indian J Thorac Cardiovasc Surg 2018; 34:251-257. [PMID: 33060946 DOI: 10.1007/s12055-018-0753-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 09/24/2018] [Accepted: 09/26/2018] [Indexed: 10/28/2022] Open
Abstract
Although the saphenous vein (SV) is a widely used conduit for coronary artery bypass graft surgery (CABG), lower long-term graft patency rates and worse clinical outcomes have been reported after CABG performed with SV grafts compared with CABG performed with internal thoracic artery (ITA) grafts. Of various efforts to overcome the limitations of SV that are resulting from structural and functional differences from arterial conduit, recent improvement in harvesting techniques including no-touch technique, surgical strategy of using the SV as part of a composite graft over an aortocoronary bypass graft, and external stenting of the SV will be discussed in this topic.
Collapse
|
23
|
Wu B, Werlin EC, Chen M, Mottola G, Chatterjee A, Lance KD, Bernards DA, Sansbury BE, Spite M, Desai TA, Conte MS. Perivascular delivery of resolvin D1 inhibits neointimal hyperplasia in a rabbit vein graft model. J Vasc Surg 2018; 68:188S-200S.e4. [PMID: 30064835 PMCID: PMC6252159 DOI: 10.1016/j.jvs.2018.05.206] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2017] [Accepted: 05/15/2018] [Indexed: 12/31/2022]
Abstract
OBJECTIVE Inflammation is a key driver of excessive neointimal hyperplasia within vein grafts. Recent work demonstrates that specialized proresolving lipid mediators biosynthesized from omega-3 polyunsaturated fatty acids, such as resolvin D1 (RvD1), actively orchestrate the process of inflammation resolution. We investigated the effects of local perivascular delivery of RvD1 in a rabbit vein graft model. METHODS Ipsilateral jugular veins were implanted as carotid interposition grafts through an anastomotic cuff technique in New Zealand white rabbits (3-4 kg; N = 80). RvD1 (1 μg) was delivered to the vein bypass grafts in a perivascular fashion, using either 25% Pluronic F127 gel (Sigma-Aldrich, St. Louis, Mo) or a thin bilayered poly(lactic-co-glycolic acid) (PLGA) film. No treatment (bypass only) and vehicle-loaded Pluronic gels or PLGA films served as controls. Delivery of RvD1 to venous tissue was evaluated 3 days later by liquid chromatography-tandem mass spectrometry. Total leukocyte infiltration, macrophage infiltration, and cell proliferation were evaluated by immunohistochemistry. Elastin and trichrome staining was performed on grafts harvested at 28 days after bypass to evaluate neointimal hyperplasia and vein graft remodeling. RESULTS Perivascular treatments did not influence rates of graft thrombosis (23%), major wound complications (4%), or death (3%). Leukocyte (CD45) and macrophage (RAM11) infiltration was significantly reduced in the RvD1 treatment groups vs controls at 3 days (60%-72% reduction; P < .01). Cellular proliferation (Ki67 index) was also significantly lower in RvD1-treated vs control grafts at 3 days (40%-50% reduction; P < .01). Treatment of vein grafts with RvD1-loaded gels reduced neointimal thickness at 28 days by 61% vs bypass only (P < .001) and by 63% vs vehicle gel (P < .001). RvD1-loaded PLGA films reduced neointimal formation at 28 days by 50% vs bypass only (P < .001). RvD1 treatment was also associated with reduced collagen deposition in vein grafts at 28 days. CONCLUSIONS Local perivascular delivery of RvD1 attenuates vein graft hyperplasia without associated toxicity in a rabbit carotid bypass model. This effect appears to be mediated by both reduced leukocyte recruitment and decreased cell proliferation within the graft. Perivascular PLGA films may also impart protection through biomechanical scaffolding in this venous arterialization model. Our studies provide further support for the potential therapeutic role of specialized proresolving lipid mediators such as D-series resolvins in modulating vascular injury and repair.
Collapse
Affiliation(s)
- Bian Wu
- Department of Surgery and Cardiovascular Research Institute, University of California, San Francisco, Calif
| | - Evan C Werlin
- Department of Surgery and Cardiovascular Research Institute, University of California, San Francisco, Calif
| | - Mian Chen
- Department of Surgery and Cardiovascular Research Institute, University of California, San Francisco, Calif
| | - Giorgio Mottola
- Department of Surgery and Cardiovascular Research Institute, University of California, San Francisco, Calif
| | - Anuran Chatterjee
- Department of Surgery and Cardiovascular Research Institute, University of California, San Francisco, Calif
| | - Kevin D Lance
- Department of Bioengineering, University of California, San Francisco, Calif
| | - Daniel A Bernards
- Department of Bioengineering, University of California, San Francisco, Calif
| | - Brian E Sansbury
- Center for Experimental Therapeutics and Reperfusion Injury, Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital and Harvard Medical School, Boston, Mass
| | - Matthew Spite
- Center for Experimental Therapeutics and Reperfusion Injury, Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital and Harvard Medical School, Boston, Mass
| | - Tejal A Desai
- Department of Bioengineering, University of California, San Francisco, Calif
| | - Michael S Conte
- Department of Surgery and Cardiovascular Research Institute, University of California, San Francisco, Calif.
| |
Collapse
|
24
|
Loesch A, Dashwood MR. Vasa vasorum inside out/outside in communication: a potential role in the patency of saphenous vein coronary artery bypass grafts. J Cell Commun Signal 2018; 12:631-643. [PMID: 30078142 PMCID: PMC6235771 DOI: 10.1007/s12079-018-0483-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2018] [Accepted: 07/30/2018] [Indexed: 01/08/2023] Open
Abstract
The saphenous vein (SV) is the most commonly used conduit for revascularization in patients undergoing coronary artery bypass surgery (CABG). The patency rate of this vessel is inferior to the internal thoracic artery (ITA). In the majority of CABG procedures the ITA is removed with its outer pedicle intact whereas the (human) SV (hSV) is harvested with pedicle removed. The vasa vasorum, a microvessel network providing the adventitia and media with oxygen and nutrients, is more pronounced and penetrates deeper towards the lumen in veins than in arteries. When prepared in conventional CABG the vascular trauma caused when removing the hSV pedicle damages the vasa vasorum, a situation affecting transmural flow potentially impacting on graft performance. In patients, where the hSV is harvested with pedicle intact, the vasa vasorum is preserved and transmural blood flow restored at graft insertion and completion of CABG. By maintaining blood supply to the hSV wall, apart from oxygen and nutrients, the vasa vasorum may also transport factors potentially beneficial to graft performance. Studies, using either corrosion casts or India ink, have shown the course of vasa vasorum in animal SV as well as in hSV. In addition, there is some evidence that vasa vasorum of hSV terminate in the vessel lumen based on ex vivo perfusion, histological and ultrastructural studies. This review describes the preparation of the hSV as a bypass conduit in CABG and its performance compared with the ITA as well as how and why its patency might be improved by harvesting with minimal trauma in a way that preserves an intact vasa vasorum.
Collapse
Affiliation(s)
- Andrzej Loesch
- Centre for Rheumatology and Connective Tissue Diseases, Division of Medicine, University College London Medical School, Royal Free Campus, Rowland Hill Street, London, NW3 2PF, UK.
| | - Michael R Dashwood
- Division of Surgery and Interventional Science, Faculty of Medical Sciences, University College London Medical School, Royal Free Campus, Rowland Hill Street, London, NW3 2PF, UK.
| |
Collapse
|
25
|
Mawhinney JA, Mounsey CA, Taggart DP. The potential role of external venous supports in coronary artery bypass graft surgery†. Eur J Cardiothorac Surg 2017; 53:1127-1134. [DOI: 10.1093/ejcts/ezx432] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2017] [Accepted: 11/07/2017] [Indexed: 11/12/2022] Open
Affiliation(s)
| | | | - David P Taggart
- Department of Cardiothoracic Surgery, Oxford University Hospitals NHS Trust, Oxford, UK
| |
Collapse
|
26
|
Mylonaki I, Allémann É, Saucy F, Haefliger JA, Delie F, Jordan O. Perivascular medical devices and drug delivery systems: Making the right choices. Biomaterials 2017; 128:56-68. [PMID: 28288349 DOI: 10.1016/j.biomaterials.2017.02.028] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Revised: 02/13/2017] [Accepted: 02/26/2017] [Indexed: 12/31/2022]
Abstract
Perivascular medical devices and perivascular drug delivery systems are conceived for local application around a blood vessel during open vascular surgery. These systems provide mechanical support and/or pharmacological activity for the prevention of intimal hyperplasia following vessel injury. Despite abundant reports in the literature and numerous clinical trials, no efficient perivascular treatment is available. In this review, the existing perivascular medical devices and perivascular drug delivery systems, such as polymeric gels, meshes, sheaths, wraps, matrices, and metal meshes, are jointly evaluated. The key criteria for the design of an ideal perivascular system are identified. Perivascular treatments should have mechanical specifications that ensure system localization, prolonged retention and adequate vascular constriction. From the data gathered, it appears that a drug is necessary to increase the efficacy of these systems. As such, the release kinetics of pharmacological agents should match the development of the pathology. A successful perivascular system must combine these optimized pharmacological and mechanical properties to be efficient.
Collapse
Affiliation(s)
- Ioanna Mylonaki
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, rue Michel Servet 1, CH-1211 Geneva 4, Switzerland
| | - Éric Allémann
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, rue Michel Servet 1, CH-1211 Geneva 4, Switzerland
| | - François Saucy
- Department of Vascular Surgery, Lausanne University Hospital, rue du Bugnon 46, CH-1011 Lausanne, Switzerland
| | - Jacques-Antoine Haefliger
- Department of Vascular Surgery, Lausanne University Hospital, rue du Bugnon 46, CH-1011 Lausanne, Switzerland
| | - Florence Delie
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, rue Michel Servet 1, CH-1211 Geneva 4, Switzerland
| | - Olivier Jordan
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, rue Michel Servet 1, CH-1211 Geneva 4, Switzerland.
| |
Collapse
|
27
|
Boire TC, Balikov DA, Lee Y, Guth CM, Cheung-Flynn J, Sung HJ. Biomaterial-Based Approaches to Address Vein Graft and Hemodialysis Access Failures. Macromol Rapid Commun 2016; 37:1860-1880. [PMID: 27673474 PMCID: PMC5156561 DOI: 10.1002/marc.201600412] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 08/15/2016] [Indexed: 12/19/2022]
Abstract
Veins used as grafts in heart bypass or as access points in hemodialysis exhibit high failure rates, thereby causing significant morbidity and mortality for patients. Interventional or revisional surgeries required to correct these failures have been met with limited success and exorbitant costs, particularly for the US Centers for Medicare & Medicaid Services. Vein stenosis or occlusion leading to failure is primarily the result of neointimal hyperplasia. Systemic therapies have achieved little long-term success, indicating the need for more localized, sustained, biomaterial-based solutions. Numerous studies have demonstrated the ability of external stents to reduce neointimal hyperplasia. However, successful results from animal models have failed to translate to the clinic thus far, and no external stent is currently approved for use in the US to prevent vein graft or hemodialysis access failures. This review discusses current progress in the field, design considerations, and future perspectives for biomaterial-based external stents. More comparative studies iteratively modulating biomaterial and biomaterial-drug approaches are critical in addressing mechanistic knowledge gaps associated with external stent application to the arteriovenous environment. Addressing these gaps will ultimately lead to more viable solutions that prevent vein graft and hemodialysis access failures.
Collapse
Affiliation(s)
- Timothy C Boire
- Department of Biomedical Engineering, Vanderbilt University, 37235, Nashville, TN, USA
| | - Daniel A Balikov
- Department of Biomedical Engineering, Vanderbilt University, 37235, Nashville, TN, USA
| | - Yunki Lee
- Department of Biomedical Engineering, Vanderbilt University, 37235, Nashville, TN, USA
| | - Christy M Guth
- Division of Vascular Surgery, Department of Surgery, Vanderbilt University Medical Center, Nashville, TN, 37235, USA
| | - Joyce Cheung-Flynn
- Division of Vascular Surgery, Department of Surgery, Vanderbilt University Medical Center, Nashville, TN, 37235, USA
| | - Hak-Joon Sung
- Department of Biomedical Engineering, Vanderbilt University, 37235, Nashville, TN, USA
- Severance Biomedical Science Institute, College of Medicine, Yonsei University, Seoul, 120-752, Republic of Korea
| |
Collapse
|
28
|
de Vries MR, Simons KH, Jukema JW, Braun J, Quax PHA. Vein graft failure: from pathophysiology to clinical outcomes. Nat Rev Cardiol 2016; 13:451-70. [PMID: 27194091 DOI: 10.1038/nrcardio.2016.76] [Citation(s) in RCA: 197] [Impact Index Per Article: 24.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Occlusive arterial disease is a leading cause of morbidity and mortality worldwide. Aside from balloon angioplasty, bypass graft surgery is the most commonly performed revascularization technique for occlusive arterial disease. Coronary artery bypass graft surgery is performed in patients with left main coronary artery disease and three-vessel coronary disease, whereas peripheral artery bypass graft surgery is used to treat patients with late-stage peripheral artery occlusive disease. The great saphenous veins are commonly used conduits for surgical revascularization; however, they are associated with a high failure rate. Therefore, preservation of vein graft patency is essential for long-term surgical success. With the exception of 'no-touch' techniques and lipid-lowering and antiplatelet (aspirin) therapy, no intervention has hitherto unequivocally proven to be clinically effective in preventing vein graft failure. In this Review, we describe both preclinical and clinical studies evaluating the pathophysiology underlying vein graft failure, and the latest therapeutic options to improve patency for both coronary and peripheral grafts.
Collapse
Affiliation(s)
- Margreet R de Vries
- Department of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, Netherlands.,Einthoven Laboratory for Experimental Vascular Medicine, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, Netherlands
| | - Karin H Simons
- Department of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, Netherlands.,Einthoven Laboratory for Experimental Vascular Medicine, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, Netherlands
| | - J Wouter Jukema
- Einthoven Laboratory for Experimental Vascular Medicine, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, Netherlands.,Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, Netherlands
| | - Jerry Braun
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, Netherlands
| | - Paul H A Quax
- Department of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, Netherlands.,Einthoven Laboratory for Experimental Vascular Medicine, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, Netherlands
| |
Collapse
|
29
|
A novel biodegradable external mesh stent improved long-term patency of vein grafts by inhibiting intimal–medial hyperplasia in an experimental canine model. Gen Thorac Cardiovasc Surg 2015; 64:1-9. [DOI: 10.1007/s11748-015-0591-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Accepted: 09/17/2015] [Indexed: 10/23/2022]
|
30
|
A Randomized Trial of External Stenting for Saphenous Vein Grafts in Coronary Artery Bypass Grafting. Ann Thorac Surg 2015; 99:2039-45. [DOI: 10.1016/j.athoracsur.2015.01.060] [Citation(s) in RCA: 68] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Revised: 01/11/2015] [Accepted: 01/15/2015] [Indexed: 11/23/2022]
|
31
|
Singh C, Wang X. A new design concept for knitted external vein-graft support mesh. J Mech Behav Biomed Mater 2015; 48:125-133. [PMID: 25916819 DOI: 10.1016/j.jmbbm.2015.04.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2015] [Revised: 03/31/2015] [Accepted: 04/01/2015] [Indexed: 11/24/2022]
Abstract
Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh.
Collapse
Affiliation(s)
- Charanpreet Singh
- Australian Future Fibres Research and Innovation Centre, Institute for Frontier Materials, Deakin University, Geelong, Victoria 3216, Australia
| | - Xungai Wang
- Australian Future Fibres Research and Innovation Centre, Institute for Frontier Materials, Deakin University, Geelong, Victoria 3216, Australia; School of Textile Science and Engineering, Wuhan Textile University, Wuhan 430073, China.
| |
Collapse
|
32
|
|
33
|
The use of external mesh reinforcement to reduce intimal hyperplasia and preserve the structure of human saphenous veins. Biomaterials 2014; 35:2588-99. [DOI: 10.1016/j.biomaterials.2013.12.041] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2013] [Accepted: 12/18/2013] [Indexed: 01/14/2023]
|
34
|
Huang WC, Newby GB, Lewis AL, Stratford PW, Rogers CA, Newby AC, Murphy GJ. Periadventitial human stem cell treatment reduces vein graft intimal thickening in pig vein-into-artery interposition grafts. J Surg Res 2013; 183:33-9. [DOI: 10.1016/j.jss.2012.11.060] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2012] [Revised: 11/06/2012] [Accepted: 11/30/2012] [Indexed: 11/27/2022]
|
35
|
Abstract
Saphenous vein remains a widely used conduit in coronary surgery. However, the long-term success of surgical myocardial revascularization is largely limited by the development of neointimal hyperplasia and superimposed atherosclerosis in vein grafts. Although strategies for preventing vein graft failure have been constantly explored, few therapeutic interventions to date have shown sustained benefits in the clinical setting. The application of external support has emerged as a promising strategy for modulating the overall biomechanical responses in venous wall. Nonetheless, clinical translation of this intervention has been formerly challenged, primarily due to several technique limitations. The purpose of the current review is to summarize the possible mechanisms involved in the external support strategy for preventing vein graft failure. Furthermore, several previously tested biomaterials and delivery techniques are also highlighted.
Collapse
Affiliation(s)
- Jia Hu
- Division of Cardiothoracic Surgery, Department of Surgery, The Chinese University of Hong Kong, Prince of Wales Hospital, Hong Kong, People's Republic of China
| | | |
Collapse
|
36
|
|
37
|
Dashwood MR, Tsui JC. 'No-touch' saphenous vein harvesting improves graft performance in patients undergoing coronary artery bypass surgery: a journey from bedside to bench. Vascul Pharmacol 2012; 58:240-50. [PMID: 22967905 DOI: 10.1016/j.vph.2012.07.008] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2012] [Revised: 07/14/2012] [Accepted: 07/31/2012] [Indexed: 11/19/2022]
Abstract
The saphenous vein is the most commonly used conduit in patients undergoing coronary artery bypass surgery yet its patency is inferior to the internal thoracic artery. Vascular damage inflicted to the vein when using conventional harvesting techniques affects its structure. Endothelial denudation is associated with early vein graft failure while damage of the outermost vessel layers has adverse long-term effects on graft performance. While many in vitro and in vivo experimental studies aimed at improving vein graft patency have been performed to date no significant 'bench to bedside' advances have been made. Among experimental strategies employed is the use of pharmacological agents, gene targeting and external stents. A 'no-touch' technique, where the saphenous vein is removed with minimal trauma and normal architecture preserved, produces a superior graft with long term patency comparable to the internal thoracic artery. Interestingly, many experimental studies are aimed at repairing or replacing those regions of the saphenous vein damaged when harvesting conventionally. 'No-touch' harvesting is superior in coronary artery bypass patients with long-term data published 5years ago. Here we describe a 'bedside to bench' situation where the mechanisms underlying the improved performance of 'no touch' saphenous vein grafts in patients have been studied in the laboratory.
Collapse
Affiliation(s)
- Michael R Dashwood
- Department of Clinical Biochemistry, Royal Free and University College Medical School, Pond Street, London NW3 2QG, United Kingdom.
| | | |
Collapse
|
38
|
Shukla N, Jeremy JY. Pathophysiology of saphenous vein graft failure: a brief overview of interventions. Curr Opin Pharmacol 2012; 12:114-20. [PMID: 22321569 DOI: 10.1016/j.coph.2012.01.001] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2011] [Revised: 01/05/2012] [Accepted: 01/06/2012] [Indexed: 12/01/2022]
Abstract
Coronary artery bypass graft surgery (CABG) is widely used for the treatment of atheromatous stenosis of coronary arteries. However, as many as 50% of grafts fail within 10 years after CABG due to neointima (NI) formation, a process involving the proliferation of vascular smooth muscle cells (VSMCs) and superimposed atherogenesis. To date no therapeutic intervention has proved successful in treating late vein graft failure. However, several diverse approaches aimed at preventing neointimal formation have been devised which have yielded promising results. In this review, therefore, we will summarise the pathophysiology of vein graft disease and then briefly consider interventional approaches to prevent late vein graft failure which include surgical technique, conventional pharmacology, external sheaths, cytostatic drugs and gene transfer.
Collapse
Affiliation(s)
- Nilima Shukla
- Bristol Heart Institute, The University of Bristol, UK.
| | | |
Collapse
|
39
|
Bello SOZ, Peng EWK, Sarkar PK. Conduits for coronary artery bypass surgery: the quest for second best. J Cardiovasc Med (Hagerstown) 2011; 12:411-21. [DOI: 10.2459/jcm.0b013e328345a20d] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
40
|
Zou J, Zhang X, Yang H, Zhu Y, Ma H, Wang S. Rapamycin-loaded nanoparticles for inhibition of neointimal hyperplasia in experimental vein grafts. J Cardiothorac Surg 2011; 6:69. [PMID: 21569412 PMCID: PMC3115851 DOI: 10.1186/1749-8090-6-69] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2010] [Accepted: 05/12/2011] [Indexed: 11/26/2022] Open
Abstract
Background Nanoparticles possess several advantages as a carrier system for intracellular delivery of therapeutic agents. Rapamycin is an immunosuppressive agent which also exhibits marked antiproliferative properties. We investigated whether rapamycin-loaded nanoparticles(NPs) can reduce neointima formation in a rat model of vein graft disease. Methods Poly(lactic-co-glycolic acid) (PLGA) NPs containing rapamycin was prepared using an oil/water solvent evaporation technique. Nanoparticle size and morphology were determined by dynamic light scattering methodology and electron microscopy. In vitro cytotoxicity of blank, rapamycin-loaded PLGA (RPLGA) NPs was studied using MTT Assay. Excised rat jugular vein was treated ex vivo with blank-NPs, or rapamycin-loaded NPs, then interposed back into the carotid artery position using a cuff technique. Grafts were harvested at 21 days and underwent morphometric analysis as well as immunohistochemical analysis. Results Rapamycin was efficiently loaded in PLGA nanoparticles with an encapsulation efficiency was 87.6%. The average diameter of NPs was 180.3 nm. The NPs-containing rapamycin at 1 ng/ml significantly inhibited vascular smooth muscular cells proliferation. Measurement of rapamycin levels in vein grafts shown that the concentration of rapamycin in vein grafts at 3 weeks after grafting were 0.9 ± 0.1 μg/g. In grafted veins without treatment intima-media thickness was 300.4 ±181.5 μm after grafting 21 days. Whereas, Veins treated with rapamycin-loaded NPs showed a reduction of intimal-media thickness of 150.2 ± 62.5 μm (p = 0.001). CD-31 staining was used to measure luminal endothelial coverage in grafts and indicated a high level of endothelialization in 21 days vein grafts with no significant effect of blank or rapamycin-loaded NPs group. Conclusions We conclude that sustained-release rapamycin from rapymycin loaded NPs inhibits vein graft thickening without affecting the reendothelialization in rat carotid vein-to-artery interposition grafts and this may be a promising therapy for the treatment of vein graft disease.
Collapse
Affiliation(s)
- Junjie Zou
- Department of General Surgery, the First Affiliated Hospital of Nanjing Medical University, Nanjng, Jiangsu province, China
| | | | | | | | | | | |
Collapse
|
41
|
Rapamycin-Loaded Nanoparticles for Inhibition of Neointimal Hyperplasia in Experimental Vein Grafts. Ann Vasc Surg 2011; 25:538-46. [PMID: 21549923 DOI: 10.1016/j.avsg.2011.01.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2010] [Revised: 01/22/2011] [Accepted: 01/26/2011] [Indexed: 11/21/2022]
|
42
|
Franz T, Human P, Dobner S, Reddy BD, Black M, Ilsley H, Wolf MF, Bezuidenhout D, Moodley L, Zilla P. Tailored sizes of constrictive external vein meshes for coronary artery bypass surgery. Biomaterials 2010; 31:9301-9. [DOI: 10.1016/j.biomaterials.2010.08.054] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2010] [Accepted: 08/24/2010] [Indexed: 10/19/2022]
|
43
|
Rajathurai T, Rizvi SI, Lin H, Angelini GD, Newby AC, Murphy GJ. Periadventitial rapamycin-eluting microbeads promote vein graft disease in long-term pig vein-into-artery interposition grafts. Circ Cardiovasc Interv 2010; 3:157-65. [PMID: 20332383 DOI: 10.1161/circinterventions.109.864660] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Neointima formation and atherosclerosis compromise long-term graft patency in aortocoronary and peripheral vein bypass grafts. We investigated the short- and long-term effects of periadventitial application of a sustained-release formulation of rapamycin on experimental pig vein grafts with similar dimensions and kinetics to human saphenous vein bypass grafts. METHODS AND RESULTS Periadventitial application of rapamycin-eluting polyvinyl alcohol microspheres (60 microg . cm(-2)) to porcine saphenous vein-to-carotid artery interposition grafts inhibited vein graft positive and vascular smooth muscle cell proliferation in 1-week grafts. It also decreased neointima formation and wall thickening in 4-week vein grafts compared with controls. The inhibition of vein graft thickening was not sustained; however, a catch-up phenomenon was observed, and there was no therapeutic benefit evident in 12-week grafts. Increasing the dose of rapamycin to 120 microg . cm(-2) was associated with significant local toxicity manifest by high rates of graft rupture (25%), inhibition of adventitial neoangiogenesis, and a paradoxical acceleration of vein graft disease as evidenced by increased vascular smooth muscle cell proliferation. CONCLUSIONS Local toxicity and poor long-term efficacy limits the clinical applicability of locally applied, sustained rapamycin release in vein graft disease.
Collapse
|
44
|
Zilla P, Wolf M, Rafiee N, Moodley L, Bezuidenhout D, Black M, Human P, Franz T. Utilization of shape memory in external vein-graft meshes allows extreme diameter constriction for suppressing intimal hyperplasia: A non-human primate study. J Vasc Surg 2009; 49:1532-42. [DOI: 10.1016/j.jvs.2009.01.068] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2008] [Revised: 01/22/2009] [Accepted: 01/31/2009] [Indexed: 11/25/2022]
|