Dorothee S, Sørensen G, Olsen LR, Bastlund JF, Sotty F, Belling D, Olsen MH, Mathiesen TI, Møller K, Larsen F, Birkeland P. Negligible In Vitro Recovery of Macromolecules from Microdialysis Using 100 kDa Probes and Dextran in Perfusion Fluid. Neurochem Res 2024; 49:1322-1330. [PMID: 38478218 PMCID: PMC10991005 DOI: 10.1007/s11064-024-04119-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 01/31/2024] [Accepted: 01/31/2024] [Indexed: 04/04/2024]
Abstract
Microdialysis is applied in neurointensive care to monitor cerebral glucose metabolism. If recoverable, macromolecules may also serve as biomarkers in brain disease and provide clues to their passage across the blood-brain barrier. Our study aimed to investigate the in vitro recovery of human micro- and macromolecules using microdialysis catheters and perfusion fluids approved for clinical use. In vitro microdialysis of a bulk solution containing physiological or supraphysiological concentrations of glucose, lactate, pyruvate, human IgG, serum albumin, and hemoglobin was performed using two different catheters and perfusion fluids. One had a membrane cut-off of 20 kDa and was used with a standard CNS perfusion fluid, and the other had a membrane cut-off of 100 kDa and was perfused with the same solution supplemented with dextran. The flow rate was 0.3 µl/min. We used both push and push-pull methods. Dialysate samples were collected at 2-h intervals for 6 h and analyzed for relative recovery of each substance. The mean relative recovery of glucose, pyruvate, and lactate was > 90% in all but two sets of experiments. In contrast, the relative recovery of human IgG, serum albumin, and hemoglobin from both bulk solutions was below the lower limit of quantification (LLOQ). Using a push-pull method, recovery of human IgG, serum albumin, and hemoglobin from a bulk solution with supraphysiological concentrations were above LLOQ but with low relative recovery (range 0.9%-1.6%). In summary, exchanging the microdialysis setup from a 20 kDa catheter with a standard perfusion fluid for a 100 kDa catheter with a perfusion solution containing dextran did not affect the relative recovery of glucose and its metabolites. However, it did not result in any useful recovery of the investigated macromolecules at physiological levels, either with or without a push-pull pump system.
Collapse
Affiliation(s)
- Spille Dorothee
- Department of Neurosurgery, University Hospital Münster, Münster, Germany
| | - G Sørensen
- H. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark
| | - L R Olsen
- H. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark
| | - J F Bastlund
- H. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark
| | - F Sotty
- H. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark
| | - D Belling
- H. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark
| | - M H Olsen
- Department of Clinical Medicine, Blegdamsvej 3, 2200, Copenhagen N, Denmark
| | - T I Mathiesen
- Department of Neurosurgery, Rigshospitalet, Inge Lehmannsvej 6, 2100, Copenhagen Ø, Denmark
- Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3, Copenhagen, Denmark
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - K Møller
- Department of Clinical Medicine, Blegdamsvej 3, 2200, Copenhagen N, Denmark
| | - F Larsen
- H. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark
| | - P Birkeland
- Department of Neurosurgery, Rigshospitalet, Inge Lehmannsvej 6, 2100, Copenhagen Ø, Denmark.
| |
Collapse
|
2
|
Microdialysis techniques and microdialysis-based patient-near diagnostics. Anal Bioanal Chem 2022; 414:3165-3175. [PMID: 35028692 DOI: 10.1007/s00216-021-03830-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 11/17/2021] [Accepted: 12/03/2021] [Indexed: 01/04/2023]
Abstract
This article will debate the usefulness of POCT measurements and the contribution microdialysis can make to generating valuable information. A particular theme will be the rarely considered difference between ex vivo sampling, which typically generates only a static measure of concentration, and in vivo measurements that are subject to dynamic changes due to mass transfer. Those dynamic changes provide information about the patients' physiological state.
Collapse
|
3
|
Cytokine and Chemokine Recovery Is Increased by Colloid Perfusates during Dermal Microdialysis. MATERIALS 2018; 11:ma11050682. [PMID: 29702553 PMCID: PMC5978059 DOI: 10.3390/ma11050682] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 04/16/2018] [Accepted: 04/23/2018] [Indexed: 01/23/2023]
Abstract
Cytokines and chemokines play important roles in cell signalling, and microdialysis is a promising tool for monitoring these inflammation markers ex vivo. Therefore, the collecting of these mediators at the highest concentrations possible is crucial. Depending on the size of the mediator of interest, the collection of these high molecular mass molecules has thus far been difficult due to their low recovery, even when using high cut-off (100 kDa) microdialysis membranes. This study aimed to optimize the recovery of various cytokines and chemokines by validating the use of different perfusates in cutaneous microdialysis, and comparing intravenous (i.v.) colloids, crystalloids, and a lipid emulsion formulations that are approved for i.v. applications. Methods: In vitro and in vivo recovery experiments using six recombinant cytokines varying in molecular size (interleukin-2 (15 kDa), interleukin-6 (20.5 kDa), interleukin-8 (8 kDa), interleukin-12p70 (70 kDa), TNF-α (17.5 kDa), and vascular endothelial growth factor (VEGF) (38 kDa)) were performed in the presence of different perfusates for i.v. applications: Ringer’s lactate, dextran 60 kDa, hydroxyethyl starch 70 kDa, and hydroxyethyl starch 200 kDa solutions as well as a lipid emulsion formulation. Recovery was determined through (i) microdialysis of cytokines and chemokines in Ringer’s lactate solution or human serum in vitro, and (ii) retrodialysis of excised porcine and human skin cadavers in vitro and porcine skin in vivo. Furthermore, we used skin trauma (catheter insertion) and Ultraviolet B irradiation of 3 × 3 cm2 skin areas to sample cytokines and chemokines in vivo and compared the amounts that were obtained using crystalloid and colloid perfusates. All the cytokines and chemokines within the dialysates were quantified through a flow cytometry-based bead array assay. Results: Overall, recovery was strongly increased by the colloids, particularly hydroxyethyl starch 70 kDa, in vitro, ex vivo, and in vivo. When compared with the recovery achieved using Ringer’s lactate, this increase was most effective for proteins ranging from 8 to 20.5 kDa. Hydroxyethyl starch 70 kDa significantly increased the recovery of interleukin (IL)-8 in human serum in vitro when compared with Ringer’s lactate. More cytokines and chemokines were recovered using colloids compared with crystalloids. However, the increase in recovery values was lower for IL-12p70 and VEGF. Conclusions: Regarding the dialysate volumes and final dialysate concentrations, colloid perfusates are overall superior to crystalloid perfusates, such as Ringer’s lactate, when sampling cytokines and chemokines, resulting in higher recoveries. However, the sampling of high-molecular-mass cytokines during microdialysis remains challenging, and experimental in vitro data are not completely comparable with data obtained ex vivo or in vivo.
Collapse
|
4
|
Gowers SAN, Hamaoui K, Cunnea P, Anastasova S, Curto VF, Vadgama P, Yang GZ, Papalois V, Drakakis EM, Fotopoulou C, Weber SG, Boutelle MG. High temporal resolution delayed analysis of clinical microdialysate streams. Analyst 2018; 143:715-724. [PMID: 29336454 PMCID: PMC5804479 DOI: 10.1039/c7an01209h] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Accepted: 10/19/2017] [Indexed: 12/26/2022]
Abstract
This paper presents the use of tubing to store clinical microdialysis samples for delayed analysis with high temporal resolution, offering an alternative to traditional discrete offline microdialysis sampling. Samples stored in this way were found to be stable for up to 72 days at -80 °C. Examples of how this methodology can be applied to glucose and lactate measurement in a wide range of in vivo monitoring experiments are presented. This paper presents a general model, which allows for an informed choice of tubing parameters for a given storage time and flow rate avoiding high back pressure, which would otherwise cause the microdialysis probe to leak, while maximising temporal resolution.
Collapse
Affiliation(s)
- S. A. N. Gowers
- Department of Bioengineering , Imperial College , London , SW7 2AZ , UK .
| | - K. Hamaoui
- Department of Surgery & Cancer , Imperial College , London , SW7 2AZ , UK
| | - P. Cunnea
- Ovarian Cancer Action Research Centre , Department of Surgery & Cancer , Imperial College , London , W12 0NN , UK
| | - S. Anastasova
- The Hamlyn Centre , Imperial College , London , SW7 2AZ , UK
| | - V. F. Curto
- The Hamlyn Centre , Imperial College , London , SW7 2AZ , UK
| | - P. Vadgama
- School of Engineering and Materials Science , Queen Mary , University of London , Mile End Road , London , E1 4NS , UK
| | - G.-Z. Yang
- The Hamlyn Centre , Imperial College , London , SW7 2AZ , UK
| | - V. Papalois
- Department of Surgery & Cancer , Imperial College , London , SW7 2AZ , UK
| | - E. M. Drakakis
- Department of Bioengineering , Imperial College , London , SW7 2AZ , UK .
| | - C. Fotopoulou
- Ovarian Cancer Action Research Centre , Department of Surgery & Cancer , Imperial College , London , W12 0NN , UK
| | - S. G. Weber
- Department of Chemistry , University of Pittsburgh , PA 15260 , USA
| | - M. G. Boutelle
- Department of Bioengineering , Imperial College , London , SW7 2AZ , UK .
| |
Collapse
|
5
|
Hammarlund-Udenaes M. Microdialysis as an Important Technique in Systems Pharmacology—a Historical and Methodological Review. AAPS JOURNAL 2017; 19:1294-1303. [DOI: 10.1208/s12248-017-0108-2] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2017] [Accepted: 06/01/2017] [Indexed: 01/03/2023]
|
6
|
A Review on Microdialysis Calibration Methods: the Theory and Current Related Efforts. Mol Neurobiol 2016; 54:3506-3527. [PMID: 27189617 DOI: 10.1007/s12035-016-9929-8] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Accepted: 05/03/2016] [Indexed: 10/21/2022]
Abstract
Microdialysis is a sampling technique first introduced in the late 1950s. Although this technique was originally designed to study endogenous compounds in animal brain, it is later modified to be used in other organs. Additionally, microdialysis is not only able to collect unbound concentration of compounds from tissue sites; this technique can also be used to deliver exogenous compounds to a designated area. Due to its versatility, microdialysis technique is widely employed in a number of areas, including biomedical research. However, for most in vivo studies, the concentration of substance obtained directly from the microdialysis technique does not accurately describe the concentration of the substance on-site. In order to relate the results collected from microdialysis to the actual in vivo condition, a calibration method is required. To date, various microdialysis calibration methods have been reported, with each method being capable to provide valuable insights of the technique itself and its applications. This paper aims to provide a critical review on various calibration methods used in microdialysis applications, inclusive of a detailed description of the microdialysis technique itself to start with. It is expected that this article shall review in detail, the various calibration methods employed, present examples of work related to each calibration method including clinical efforts, plus the advantages and disadvantages of each of the methods.
Collapse
|
7
|
Chu J, Hjort K, Larsson A, Dahlin AP. Impact of static pressure on transmembrane fluid exchange in high molecular weight cut off microdialysis. Biomed Microdevices 2014; 16:301-10. [PMID: 24370572 DOI: 10.1007/s10544-013-9833-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
With the interest of studying larger biomolecules by microdialysis (MD), this sampling technique has reached into the ultrafiltration region of fluid exchange, where fluid recovery (FR) has a strong dependence on pressure. Hence in this study, we focus on the fluid exchange across the high molecular weight cut off MD membrane under the influence of the static pressure in the sampling environment. A theoretical model is presented for MD with such membranes, where FR has a linear dependence upon the static pressure of the sample. Transmembrane (TM) osmotic pressure difference and MD perfusion rate decide how fast FR increases with increased static pressure. A test chamber for in vitro MD under static pressure was constructed and validated. It can hold four MD probes under controlled pressurized conditions. Comparison showed good agreement between experiment and theory. Moreover, test results showed that the fluid recovery of the test chamber MD can be set accurately via the chamber pressure, which is controlled by sample injection into the chamber at precise rate. This in vitro system is designed for modelling in vivo MD in cerebrospinal fluid and studies with biological samples in this system may be good models for in vivo MD.
Collapse
Affiliation(s)
- Jiangtao Chu
- Department of Engineering Sciences, Uppsala University, Box 534, 751 21, Uppsala, Sweden
| | | | | | | |
Collapse
|
8
|
Chu J, Koudriavtsev V, Hjort K, Dahlin AP. Fluorescence imaging of macromolecule transport in high molecular weight cut-off microdialysis. Anal Bioanal Chem 2014; 406:7601-9. [PMID: 25286875 DOI: 10.1007/s00216-014-8192-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2014] [Revised: 08/29/2014] [Accepted: 09/15/2014] [Indexed: 11/30/2022]
Abstract
When microdialysis (MD) membrane exceeds molecular weight cut-off (MWCO) of 100 kDa, the fluid mechanics are in the ultrafiltration regime. Consequently, fluidic mass transport of macromolecules in the perfusate over the membrane may reduce the biological relevance of the sampling and cause an inflammatory response in the test subject. Therefore, a method to investigate the molecular transport of high MWCO MD is presented. An in vitro test chamber was fabricated to facilitate the fluorescent imaging of the MD sampling process, using fluoresceinylisothiocyanate (FITC) dextran and fluorescence microscopy. Qualitative studies on dextran behavior inside and outside the membrane were performed. Semiquantitative results showed clear dextran leakage from both 40 and 250 kDa dextran when 100 kDa MWCO membranes were used. Dextran 40 kDa leaked out with an order of magnitude higher concentration and the leakage pattern resembled more of a convective flow pattern compared with dextran 250 kDa, where the leakage pattern was more diffusion based. No leakage was observed when dextran 500 kDa was used as a colloid osmotic agent. The results in this study suggest that fluorescence imaging could be used as a method for qualitative and semiquantitative molecular transport and fluid dynamics studies of MD membranes and other hollow fiber catheter membranes.
Collapse
Affiliation(s)
- Jiangtao Chu
- Department of Engineering Sciences, Uppsala University, Box 534, 751 21, Uppsala, Sweden
| | | | | | | |
Collapse
|
9
|
Zhang J, Jaquins-Gerstl A, Nesbitt KM, Rutan SC, Michael AC, Weber SG. In vivo monitoring of serotonin in the striatum of freely moving rats with one minute temporal resolution by online microdialysis-capillary high-performance liquid chromatography at elevated temperature and pressure. Anal Chem 2013; 85:9889-97. [PMID: 24020786 DOI: 10.1021/ac4023605] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Online monitoring of serotonin in striatal dialysate from freely moving rats was carried out for more than 16 h at 1 min time resolution using microdialysis coupled online to a capillary HPLC system operating at about 500 bar and 50 °C. Several aspects of the system were optimized toward robust, in vivo online measurements. A two-loop, eight-port rotary injection valve demonstrated better consistency of continuous injections than the more commonly used two-loop, 10-port valve. A six-port loop injector for introducing stimulating solutions (stimulus injector) was placed in-line between the syringe pump and microdialysis probe. We minimized solute dispersion by using capillary tubing (75 μm inside diameter, 70 cm long) for the probe inlet and outlet. In vitro assessment of concentration dispersion during transport with a 30 s time resolution showed that the dispersion standard deviation for serotonin was well within the desired system temporal resolution. Each 30 or 60 s measurement reflects the integral of the true time response over the measurement time. We have accounted for this mathematically in determining the concentration dispersion during transport. The delay time between a concentration change at the probe and its detection is 7 min. The timing of injections from the stimulus injector and the cycle time for the HPLC monitoring of the flow stream were controlled. The electrochemical detector contained a 13 μm spacer to minimize detector dead volume. During in vivo experiments, retention time and separation efficiency were stable and reproducible. There was no statistically significant change over 5.5 h in the electrochemical detector sensitivity factor for serotonin. Dialysate serotonin concentrations change significantly in response to a 120 mM K(+) stimulus. Release of serotonin evoked by a 10 min, 120 mM K(+) stimulation, but not for other K(+) stimuli, exhibited a reproducible, oscillating profile of dialysate serotonin concentration versus time. Infusion of fluoxetine, a serotonin uptake inhibitor, increased dialysate serotonin concentrations and stimulated release magnitude. Transient serotonin increases were observed in response to the stress associated with unexpected handling. This system is simple, efficient, reliable, and suitable for the study of serotonin neurochemistry associated with emotion and behavior.
Collapse
Affiliation(s)
- Jing Zhang
- Department of Chemistry, University of Pittsburgh , Pittsburgh, Pennsylvania 15260, United States
| | | | | | | | | | | |
Collapse
|
10
|
Clough GF, Stenken JA, Church MK. High Molecular Weight Targets and Treatments Using Microdialysis. MICRODIALYSIS IN DRUG DEVELOPMENT 2013. [DOI: 10.1007/978-1-4614-4815-0_13] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
11
|
Bungay PM, Sumbria RK, Bickel U. Unifying the mathematical modeling of in vivo and in vitro microdialysis. J Pharm Biomed Anal 2011; 55:54-63. [PMID: 21310575 DOI: 10.1016/j.jpba.2011.01.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2010] [Revised: 01/05/2011] [Accepted: 01/11/2011] [Indexed: 11/27/2022]
Abstract
A unifying approach is presented for developing mathematical models of microdialysis that are applicable to both in vitro and in vivo situations. Previous models for cylindrical probes have been limited by accommodating analyte diffusion through the surrounding medium in the radial direction only, i.e., perpendicular to the probe axis, or by incomplete incorporation of diffusion in the axial direction. Both radial and axial diffusion are included in the present work by employing two-dimensional finite element analysis. As in previous models, the nondimensional clearance modulus (Θ) represents the degree to which analyte clearance from the external medium influences diffusion through the medium for systems exhibiting analyte concentration linearity. Incorporating axial diffusion introduces a second dimensionless group, which is the length-to-radius aspect ratio of the membrane. These two parameter groups uniquely determine the external medium permeability, which is time dependent under transient conditions. At steady-state, the dependence of this permeability on the two groups can be approximated by an algebraic formula for much of the parameter ranges. Explicit steady-state expressions derived for the membrane and fluid permeabilities provide good approximations under transient conditions (quasi-steady-state assumption). The predictive ability of the unifying approach is illustrated for microdialysis of sucrose in vivo (brain) and inert media in vitro, under both well-stirred and quiescent conditions.
Collapse
Affiliation(s)
- Peter M Bungay
- National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD 20892, USA.
| | | | | |
Collapse
|
12
|
Dahlin AP, Wetterhall M, Caldwell KD, Larsson A, Bergquist J, Hillered L, Hjort K. Methodological aspects on microdialysis protein sampling and quantification in biological fluids: an in vitro study on human ventricular CSF. Anal Chem 2010; 82:4376-85. [PMID: 20465223 DOI: 10.1021/ac1007706] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
There is growing interest in sampling of protein biomarkers from the interstitial compartment of the brain and other organs using high molecular cutoff membrane microdialysis (MD) catheters. However, recent data suggest that protein sampling across such MD membranes is a highly complex process that needs to be further studied. Here, we report three major improvements for microdialysis sampling of proteins in complex biological matrixes. The improvements in this in vitro study using human ventricular cerebrospinal fluid as the sample matrix include increased fluid recovery control, decreased protein adsorption on the microdialysis membrane and materials, and novel quantitative mass spectrometry analysis. Dextrans in different concentrations and sizes were added to the perfusion fluid. It was found that dextrans with molecular mass 250 and 500 kDa provided a fluid recovery close to 100%. An improved fluid recovery precision could be obtained by self-assembly triblock polymer surface modification of the MD catheters. The modified catheters also delivered a significantly increased extraction efficiency for some of the investigated proteins. The final improvement was to analyze the dialysates with isobaric tagged (iTRAQ) proteomics, followed by tandem mass spectrometric analysis. By using this technique, 48 proteins could be quantified and analyzed with respect to their extraction efficiencies. The novel aspects of microdialysis protein sampling, detection, and quantification in biological fluids presented in this study should be considered as a first step toward better understanding and handling of the challenges associated with microdialysis sampling of proteins. The next step is to optimize the developed methodology in vivo.
Collapse
Affiliation(s)
- Andreas P Dahlin
- Department of Engineering Sciences, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden.
| | | | | | | | | | | | | |
Collapse
|