1
|
Shishov A, Markova U, Mulloyarova V, Tolstoy P, Shkaeva N, Kosyakov D, Das NK, Banerjee T. 1-(o-Tolyl)thiourea-based deep eutectic solvent as a stationary phase in flow injection analysis system for mercury and copper determination in edible oils. Talanta 2024; 282:127079. [PMID: 39442263 DOI: 10.1016/j.talanta.2024.127079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 10/18/2024] [Accepted: 10/18/2024] [Indexed: 10/25/2024]
Abstract
In this work, a novel deep eutectic solvent (DES) composed of thymol and 1-(o Tolyl)thiourea 9/1 (mol) is presented for the first time. This DES has not been described in the literature. This DES was first used as a stationary phase in an extraction column integrated into a flow injection analysis system for the simultaneous determination of mercury and copper in edible oils. The automated approach involves passing an aqueous sample solution obtained after microwave mineralization through a microcolumn of DES retained on polytetrafluoroethylene. This leading to the extraction and concentration of the analytes. The metals are then eluted with an aqueous thiourea solution for subsequent analysis by inductively coupled plasma-optical emission spectrometry. The limits of detection (LODs) for mercury and copper were 3 μg L⁻1 and 2.5 μg L⁻1, respectively. The approach demonstrated high accuracy. Relative standard deviations (RSD) for repeatability and inter-day reproducibility ranged from 3 % to 11 %. Extraction recovery of both metals exceeded 95 %, indicating the high efficiency of the DES-based extraction process. Environmental assessment using the AGREEprep method yielded a favorable environmental index of 0.54, highlighting the robustness of the approach. This novel use of DES as a stationary phase in flow injection analysis system provides a robust, efficient and environmentally friendly approach to the determination of trace metals in edible oils. This method can also be applied to the analysis of other samples.
Collapse
Affiliation(s)
- Andrey Shishov
- Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg, 199034, Russia.
| | - Ulyana Markova
- Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg, 199034, Russia
| | - Valeriia Mulloyarova
- Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg, 199034, Russia
| | - Peter Tolstoy
- Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya nab., St. Petersburg, 199034, Russia
| | - Natalya Shkaeva
- Core Facility Center "Arktika", Northern (Arctic) Federal University, 17 Nab. Severnoy Dviny, Arkhangelsk, 163002, Russia
| | - Dmitry Kosyakov
- Core Facility Center "Arktika", Northern (Arctic) Federal University, 17 Nab. Severnoy Dviny, Arkhangelsk, 163002, Russia
| | - Nipu Kumar Das
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam, 781039, India
| | - Tamal Banerjee
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam, 781039, India
| |
Collapse
|
2
|
Villar A, Merino S, Boto RA, Aizpurua J, Garcia A, Azkune M, Zubia J. Sulfites detection by surface-enhanced Raman spectroscopy: A feasibility study. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 300:122899. [PMID: 37262972 DOI: 10.1016/j.saa.2023.122899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 05/05/2023] [Accepted: 05/17/2023] [Indexed: 06/03/2023]
Abstract
The exhaustive control required for the correct wine production needs of many chemical analysis throughout the process. The most extended investigations for wine production control are focused on the quantification of total and free SO2. Most methods described in the literature have an adequate detection limit, but they usually lack reproducibility and require a previous sample treatment for the extraction of the SO2 from the wine-matrix. In this context, Surface-Enhanced Raman Spectroscopy (SERS) can be a promising technique for free SO2 determination without the need for any sample pre-processing. This work describes a proof of concept of a new methodology based on SERS and supported by Density Functional Theory (DFT) calculations to identify the active vibrational modes of the key molecules that contribute to the concentration of free SO2 in solution. Theoretical predictions and experimental outcomes are brought together to chemometrics to get a simple and real-time free SO2 monitoring. This general procedure could pave the way towards an implementation of a portable SERS detection module for in-field measurements.
Collapse
Affiliation(s)
- Alberto Villar
- Surface Chemistry Unit, Tekniker, Basque Research and Technology Alliance (BRTA), C/Iñaki Goenaga 5, 20600 Eibar, Spain.
| | - Santos Merino
- Surface Chemistry Unit, Tekniker, Basque Research and Technology Alliance (BRTA), C/Iñaki Goenaga 5, 20600 Eibar, Spain; Departamento de Electricidad y Electrónica Universidad del País Vasco, UPV/EHU, Leioa 48940, Spain
| | - Roberto A Boto
- Theory of Nanophotonics Group, Materials Physics Center (CSIC-UPV/EHU), Donostia-San Sebastián, Spain; Donostia International Physics Center, Paseo Manuel Lardizabal 5, 200018 Donostia-San Sebastian, Spain
| | - Javier Aizpurua
- Theory of Nanophotonics Group, Materials Physics Center (CSIC-UPV/EHU), Donostia-San Sebastián, Spain; Donostia International Physics Center, Paseo Manuel Lardizabal 5, 200018 Donostia-San Sebastian, Spain
| | - Aitzol Garcia
- Theory of Nanophotonics Group, Materials Physics Center (CSIC-UPV/EHU), Donostia-San Sebastián, Spain; Donostia International Physics Center, Paseo Manuel Lardizabal 5, 200018 Donostia-San Sebastian, Spain
| | - Mikel Azkune
- Department of Electronic Technology, Engineering School of Bilbao, University of the Basque Country (UPV/EHU), Torres Quevedo 1, E-48013 Bilbao, Spain
| | - Joseba Zubia
- Department of Communications Engineering, Engineering School of Bilbao, University of the Basque Country (UPV/EHU), Plaza Ingeniero Torres Quevedo, 1, E-48013 Bilbao, Spain
| |
Collapse
|
3
|
An efficient electrochemical sensor for determination of sulfite in water and soft drinks based on Ce3+-doped CuO nanocomposite. J Food Compost Anal 2022. [DOI: 10.1016/j.jfca.2022.104716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
4
|
Prasertying P, Ninlapath T, Jantawong N, Wongpakdee T, Sonsa-Ard T, Uraisin K, Saetear P, Wilairat P, Nacapricha D. Disposable Microchamber with a Microfluidic Paper-Based Lid for Generation and Membrane Separation of SO 2 Gas Employing an In Situ Electrochemical Gas Sensor for Quantifying Sulfite in Wine. Anal Chem 2022; 94:7892-7900. [PMID: 35609256 DOI: 10.1021/acs.analchem.2c00496] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
This work presents a fully disposable microchamber for gas generation of a sample solution. The microchamber consists of a cylindrical well-reactor and a paper-based microfluidic lid (μFluidic lid), which also serves as the reagent loading and dispensing unit. The base of the reactor consists of a hydrophobic membrane covering an in-house graphene electrochemical gas sensor. Fabrication of the gas sensor and the three-layer μFluidic lid is described. The μFluidic lid is designed to provide a steady addition of the acid reagent into the sample solution instead of liquid drops from a disposable syringe. There are three steps in the procedure: (i) acidification of the sample in the reactor to generate SO2 gas by the slow dispensing of the acid reagent from the μFluidic lid, (ii) diffusion of the liberated SO2 gas through the hydrophobic membrane at the base of the reactor, and (iii) in situ detection of SO2 by cathodic reduction at the graphene electrode. The device was demonstrated for quantitation of the sulfite preservative in wine without heating or stirring. The selectivity of the analysis is ensured by the combination of the gas-diffusion membrane and the selectivity of the electrochemical sensor. The linear working range is 2-60 mg L-1 SO2, with a limit of detection (3SD of intercept/slope) of 1.5 mg L-1 SO2. This in situ method has the shortest analysis time (8 min per sample) among all voltammetric methods that detect SO2(g) via membrane gas diffusion.
Collapse
Affiliation(s)
- Paithoon Prasertying
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.,Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Thita Ninlapath
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.,Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Nanthatchaphon Jantawong
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.,Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Thinnapong Wongpakdee
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.,Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Thitaporn Sonsa-Ard
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.,Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Kanchana Uraisin
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.,Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Phoonthawee Saetear
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.,Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Prapin Wilairat
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.,Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Duangjai Nacapricha
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.,Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| |
Collapse
|
5
|
Phouthavong V, Inoue H, Phomkeona K, Chounlamany V. Home-Made Membraneless Vaporization Gas-Liquid Separator for Colorimetric Determination of Ethanol in Alcoholic Beverages. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2022; 2022:7346253. [PMID: 35402059 PMCID: PMC8989598 DOI: 10.1155/2022/7346253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 03/08/2022] [Accepted: 03/21/2022] [Indexed: 06/14/2023]
Abstract
This work utilized the simplicity of a so-called membraneless vaporization (MBL-VP) unit as a gas separator for the colorimetric determination of ethanol in alcoholic beverages. A beverage sample with a volume of 1 mL was directly injected into a small container which was hung from a lid inside a closed 40 mL reused glass bottle without pretreatment such as distillation. An acidified potassium dichromate (Cr2O7 2-) acceptor solution, preadded to the glass bottle, was reduced to Chromium (III) ion by the diffusion of vaporized ethanol from the sample. After 5 min, the absorbing solution was collected for colorimetric detection at 590 nm. The unit manually quantifies ethanol in the range 1.0-90% (v/v) with satisfactory interday precision but without matrix effect (recovery 89-109%). The method was validated with the conventional distillation/pycnometer method which showed no significant difference of ethanol contents between those two methods and the declared values of 12 alcoholic beverages, indicating sufficient accuracy. Analyses of alcoholic beverages using this method were successful with benefits of simplicity, cheapness, and less energy consumption.
Collapse
Affiliation(s)
- Vanpaseuth Phouthavong
- Department of Chemistry, Faculty of Natural Sciences, National University of Laos, P.O. Box 7322, Vientiane, Laos
| | - Hayato Inoue
- Department of Environmental and Life Sciences, Toyohashi University of Technology, 1-1 Hibarigaoka Tempaku-cho, Toyohashi, Aichi 441-8580, Japan
| | - Kesiny Phomkeona
- Department of Chemistry, Faculty of Natural Sciences, National University of Laos, P.O. Box 7322, Vientiane, Laos
| | - Vanseng Chounlamany
- Department of Chemistry, Faculty of Natural Sciences, National University of Laos, P.O. Box 7322, Vientiane, Laos
| |
Collapse
|
6
|
Khamkhajorn C, Pencharee S, Jakmunee J, Youngvises N. Smartphone-based colorimetric method for determining sulfites in wine using a universal clamp sample holder and microfluidic cotton swab-based analytical device. Microchem J 2022. [DOI: 10.1016/j.microc.2021.107055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
7
|
Nawalohakul T, Charoenjiraroj P, Chantiwas R, Wilairat P, Praditweangkum W. A ninety-six well plate as headspaces with moist starch indicator paper as a cover for the determination of ascorbic acid by iodate oxidation and formation of volatile iodine. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:741-749. [PMID: 35108716 DOI: 10.1039/d1ay02050a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
This work presents the use of a 96-well plate as headspaces for the determination of ascorbic acid in samples loaded in the 96-well plate. Ascorbic acid in the sample is oxidized to iodide by the addition of excess acidic iodate solution into the well. The iodide is further oxidized by the remaining iodate to molecular iodine. A single sheet of moist starch indicator paper is immediately placed over the 96-well plate after the addition of the iodate with the moisture forming a gas seal. The iodine gas in each well diffuses through the headspace to react with the starch paper producing circular areas of a colored starch-iodine complex. After 15 min the indicator paper is scanned, and the digital images of the complex are analyzed by using ImageJ software to obtain blue intensity values. The precision of the intensity values from 12 wells containing 20 μL of 2.84 mM standard ascorbic acid is <2% relative standard deviation. Optimal conditions for detection were investigated, including the starch concentration, the acidic iodate reagent, and the measurement time. The linear calibration range of ascorbic acid is 0.284-2.84 mM, based on the plot of concentration vs. -log(reflectance). The coefficient of determination (r2) is >0.998. Samples of fruit juice and dietary supplements were analyzed for their ascorbic acid contents. The results obtained from the headspace reflectance method are not statistically different from values obtained from the titration method using paired t-tests (α = 0.05).
Collapse
Affiliation(s)
- Thichaphat Nawalohakul
- Department of Chemistry, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
| | - Pannarat Charoenjiraroj
- Department of Chemistry, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
| | - Rattikan Chantiwas
- Department of Chemistry, Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama VI Rd, Bangkok 10400, Thailand
| | - Prapin Wilairat
- Analytical Sciences and National Doping Test Institute, Mahidol University, Rama VI Rd, Bangkok 10400, Thailand
| | - Wiboon Praditweangkum
- Department of Chemistry, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
| |
Collapse
|
8
|
Fay CD, Nattestad A. LED PEDD Discharge Photometry: Effects of Software Driven Measurements for Sensing Applications. SENSORS 2022; 22:s22041526. [PMID: 35214426 PMCID: PMC8879031 DOI: 10.3390/s22041526] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 02/03/2022] [Accepted: 02/04/2022] [Indexed: 11/29/2022]
Abstract
This work explores the effects of embedded software-driven measurements on a sensory target when using a LED as a photodetector. Water turbidity is used as the sensory target in this study to explore these effects using a practical and important water quality parameter. Impacts on turbidity measurements are examined by adopting the Paired Emitter Detector Diode (PEDD) capacitive discharge technique and comparing common embedded software/firmware implementations. The findings show that the chosen software method can (a) affect the detection performance by up to 67%, (b) result in a variable sampling frequency/period, and (c) lead to an disagreement of the photo capacitance by up to 23%. Optimized code is offered to correct for these issues and its effectiveness is shown through comparative analyses, with the disagreement reduced significantly from 23% to 0.18%. Overall, this work demonstrates that the embedded software is a key and critical factor for PEDD capacitive discharge measurements and must be considered carefully for future measurements in sensor related studies.
Collapse
Affiliation(s)
- Cormac D. Fay
- SMART Infrastructure Facility, Engineering and Information Sciences, University of Wollongong, Wollongong, NSW 2522, Australia
- Correspondence:
| | - Andrew Nattestad
- School of Chemistry, Monash University, Clayton, VIC 3800, Australia; or
- Intelligent Polymer Research Institute, AIIM Facility, University of Wollongong, Wollongong, NSW 2522, Australia
| |
Collapse
|
9
|
Somboon T, Phatchana R, Tongpoothorn W, Sansuk S. A simple and green method for determination of ethanol in liquors by the conductivity measurement of the uncatalyzed esterification reaction. Lebensm Wiss Technol 2022. [DOI: 10.1016/j.lwt.2021.112593] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
10
|
A novel miniaturized electroanalytical device integrated with gas extraction for the voltammetric determination of sulfite in beverages. Anal Chim Acta 2021; 1185:339067. [PMID: 34711313 DOI: 10.1016/j.aca.2021.339067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 08/29/2021] [Accepted: 09/14/2021] [Indexed: 11/20/2022]
Abstract
Voltammetry and amperometry are inexpensive and high-performance analytical techniques. However, their lack of selectivity limits their use in complex matrices such as biological, environmental, and food samples. Therefore, voltammetric and amperometric analyses of these samples usually require time-consuming and laborious sample pretreatments. In this study, we present a simple and cost-effective approach to fabricate a miniaturized electrochemical cell that can be easily coupled to a head space-like gas extraction procedure in such a way the sample pretreatment and voltammetric detection are performed in a single step. As a proof of concept, we have used the proposed system to quantify sulfite in beverage samples after its conversion to SO2(g). Despite the simplicity and low cost of the proposed system, it provided good analytical performance and a limit of detection of 4.0 μmol L-1 was achieved after only 10 min of extraction. The proposed system is quite versatile since it can be applied to quantify any volatile electroactive species. Also, the proposed system provides a unique way to assess real-time extraction curves, which are essential to study and optimize new gas extraction procedures. Therefore, the approach described in this study could contribute to both applied and fundamental Analytical Chemistry.
Collapse
|
11
|
Zhang S, Mei J. Determination of sulfite in food and beverages using a reliable ratiometric AIE probe. NEW J CHEM 2021. [DOI: 10.1039/d1nj03747a] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The feasibility of using an “AIE + ICT” probe for a highly accurate and reliable determination of the sulfite level in food and beverages is demonstrated.
Collapse
Affiliation(s)
- Shasha Zhang
- Key Laboratory for Advanced Materials, Feringa Nobel Prize Scientist Joint Research Center, Joint International Research Laboratory for Precision Chemistry and Molecular Engineering, Institute of Fine Chemicals, School of Chemistry & Molecular Engineering, East China University of Science & Technology, 130 Meilong Road, Shanghai 200237, P. R. China
| | - Ju Mei
- Key Laboratory for Advanced Materials, Feringa Nobel Prize Scientist Joint Research Center, Joint International Research Laboratory for Precision Chemistry and Molecular Engineering, Institute of Fine Chemicals, School of Chemistry & Molecular Engineering, East China University of Science & Technology, 130 Meilong Road, Shanghai 200237, P. R. China
| |
Collapse
|
12
|
Hauser PC, Kubáň P. Capacitively coupled contactless conductivity detection for analytical techniques - Developments from 2018 to 2020. J Chromatogr A 2020; 1632:461616. [PMID: 33096295 DOI: 10.1016/j.chroma.2020.461616] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 10/09/2020] [Accepted: 10/10/2020] [Indexed: 12/20/2022]
Abstract
The developments of analytical contactless conductivity measurements based on capacitive coupling over the two years from mid-2018 to mid-2020 are covered. This mostly concerns applications of the technique in zone electrophoresis employing conventional capillaries and to a lesser extent lab-on-chip devices. However, its use for the detection in several other flow-based analytical methods has also been reported. Detection of bubbles and measurements of flow rates in two-phase flows are also recurring themes. A few new applications in stagnant aqueous samples, e.g. endpoint detection in titrations and measurement on paper-based devices, have been reported. Some variations of the design of the measuring cells and their read-out electronics have also been described.
Collapse
Affiliation(s)
- Peter C Hauser
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, CH-4056, Basel, Switzerland.
| | - Pavel Kubáň
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic.
| |
Collapse
|
13
|
|
14
|
Ayuning Tyas A, Sonsa-ard T, Uraisin K, Nacapricha D, Saetear P. Simple Flow-Based System with an In-Line Membrane Gas-liquid Separation Unit and a Contactless Conductivity Detector for the Direct Determination of Sulfite in Clear and Turbid Food Samples. MEMBRANES 2020; 10:E104. [PMID: 32443480 PMCID: PMC7281478 DOI: 10.3390/membranes10050104] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Revised: 05/11/2020] [Accepted: 05/14/2020] [Indexed: 11/17/2022]
Abstract
This study presents a simple flow-based system for the determination of the preservative agent sulfite in food and beverages. The standard method of conversion of sulfite ions into SO2 gas by acidification is employed to separate the sulfite from sample matrices. The sample is aspirated into a donor stream of sulfuric acid. A membrane gas-liquid separation unit, also called a 'gas-diffusion (GD)' unit, incorporating a polytetrafluoroethylene (PTFE) hydrophobic membrane allows the generated gas to diffuse into a stream of deionized water in the acceptor line. The dissolution of the SO2 gas leads to a change in the conductivity of water which is monitored by an in-line capacitively coupled contactless conductivity detector (C4D). The conductivity change is proportional to the concentration of sulfite in the sample. In this work, both clear (wine) and turbid (fruit juice and extracts of dried fruit) were selected to demonstrate the versatility of the developed method. The method can tolerate turbidity up to 60 Nephelometric Turbidity Units (NTUs). The linear range is 5-25 mg L-1 SO32- with precision < 2% RSD. The flow system employs a peristaltic pump for propelling all liquid lines. Quantitative results of sulfite were statistically comparable to those obtained from iodimetric titration for the wine samples.
Collapse
Affiliation(s)
| | | | | | | | - Phoonthawee Saetear
- Flow-Innovation Research for Science and Technology Laboratories (FIRST Labs), Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok 10400, Thailand; (A.A.T.); (T.S.-a.); (K.U.); (D.N.)
| |
Collapse
|
15
|
Mantim T, Chaisiwamongkhol K, Uraisin K, Hauser PC, Wilairat P, Nacapricha D. Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis. Molecules 2020; 25:E2284. [PMID: 32414012 PMCID: PMC7287826 DOI: 10.3390/molecules25102284] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 04/27/2020] [Accepted: 05/07/2020] [Indexed: 01/29/2023] Open
Abstract
This work presents a new dual-purpose detector for photometric and conductivity measurements in flow-based analysis. The photometric detector is a paired emitter-detector diode (PEDD) device, whilst the conductivity detection employs a capacitively coupled contactless conductivity detector (C4D). The flow-through detection cell is a rectangular acrylic block (ca. 2 × 2 × 1.5 cm) with cylindrical channels in Z-configuration. For the PEDD detector, the LED light source and detector are installed inside the acrylic block. The two electrodes of the C4D are silver conducting ink painted on the PEEK inlet and outlet tubing of the Z-flow cell. The dual-purpose detector is coupled with a sequential injection analysis (SIA) system for simultaneous detection of the absorbance of the orange dye and conductivity of the dissolved oral rehydration salt powder. The detector was also used for sequential measurements of creatinine and the conductivity of human urine samples. The creatinine analysis is based on colorimetric detection of the Jaffé reaction using the PEDD detector, and the conductivity of the urine, as measured by the C4D detector, is expressed in millisiemens (mS cm-1).
Collapse
Affiliation(s)
- Thitirat Mantim
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Bangkok 10400, Thailand; (K.C.); (K.U.); (P.W.)
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumwit 23 Road, Bangkok 10110, Thailand
- Center of Excellence for Innovation in Chemistry and Department of Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Korbua Chaisiwamongkhol
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Bangkok 10400, Thailand; (K.C.); (K.U.); (P.W.)
- School of Science, Mae Fah Luang University, Chiang Rai 57100, Thailand
- Center of Chemical Innovation for Sustainability (CIS), Mae Fah Luang University, Chiang Rai 57100, Thailand
| | - Kanchana Uraisin
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Bangkok 10400, Thailand; (K.C.); (K.U.); (P.W.)
- Center of Excellence for Innovation in Chemistry and Department of Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Peter C. Hauser
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland;
| | - Prapin Wilairat
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Bangkok 10400, Thailand; (K.C.); (K.U.); (P.W.)
- National Doping Control Centre, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Duangjai Nacapricha
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Bangkok 10400, Thailand; (K.C.); (K.U.); (P.W.)
- Center of Excellence for Innovation in Chemistry and Department of Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| |
Collapse
|
16
|
Sonsa-Ard T, Chantipmanee N, Fukana N, Hauser PC, Wilairat P, Nacapricha D. Contactless conductivity sensor employing moist paper as absorbent for in-situ detection of generated carbon dioxide gas. Anal Chim Acta 2020; 1118:44-51. [PMID: 32418603 DOI: 10.1016/j.aca.2020.04.044] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 03/09/2020] [Accepted: 04/17/2020] [Indexed: 11/25/2022]
Abstract
This work presents an unconventional use of capacitively coupled contactless conductivity detector (C4D) for detection of gas absorption by moist paper with potential application for chemical analysis. To be suitable for measuring conductivity of moist paper absorbent, the C4D sensor was therefore designed in planar configuration. A layer of dry filter paper, only 20 mm × 25 mm in size, was placed on the C4D sensor and the device installed inside a specifically designed vaporization chamber. A vial (16 mm i.d., 8 mm high) containing a 150-μL solution of sodium bicarbonate was placed alongside. The filter paper was loaded with 110 μL of deionized water through an injection hole in the cover lid. A 100-μL aliquot of 2 M hydrochloric acid solution was directly dispensed into the vial through a second hole in the lid to generate CO2 gas from the bicarbonate solution. It was observed that the C4D sensor gave real-time response that corresponded to the absorption of the gas and subsequent production of H+ and HCO3- in the moist paper. The monitored signal reached a constant value at 160 s after the addition of the acid. Chemistry of the absorption process and equivalent circuit for the C4D are proposed. Direct measurement of cement powder was chosen to demonstrate the potential use of this device for quantifying the CaCO3 content of the cement. The calibration curve for 0.5-3 mg CaCO3 was linear for signals recorded at 160 s: Vdc = (0.172 ± 0.005) · (mg CaCO3) + (0.016 ± 0.009), with coefficient of determination of 0.9965. Linear calibrations were also observed when the signals were monitored at various time less than 160 s. The limit of quantitation (3 SD of intercept/slope) was 0.17 mg CaCO3. The method provided acceptable precision with %RSD of 4.6 (2 mg CaCO3, n = 10).
Collapse
Affiliation(s)
- Thitaporn Sonsa-Ard
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok, 10400, Thailand
| | - Nattapong Chantipmanee
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry, University of Basel, Spitalstrasse 51, CH, 4056, Basel, Switzerland
| | - Nutnaree Fukana
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok, 10400, Thailand
| | - Peter C Hauser
- Department of Chemistry, University of Basel, Spitalstrasse 51, CH, 4056, Basel, Switzerland
| | - Prapin Wilairat
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok, 10400, Thailand
| | - Duangjai Nacapricha
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok, 10400, Thailand.
| |
Collapse
|