Wiström E, Hyacinthe JN, Lê TP, Gruetter R, Capozzi A. 129Xe Dynamic Nuclear Polarization Demystified: The Influence of the Glassing Matrix on the Radical Properties. J Phys Chem Lett 2024; 15:2957-2965. [PMID: 38453156 PMCID: PMC10961830 DOI: 10.1021/acs.jpclett.4c00177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 02/14/2024] [Accepted: 02/21/2024] [Indexed: 03/09/2024]
Abstract
129Xe dissolution dynamic nuclear polarization (DNP) is a controversial topic. The gold standard technique for hyperpolarized xenon magnetic resonance imaging (MRI) is spin exchange optical pumping, which received FDA approval in 2022. Nevertheless, the versatility of DNP for enhancing the signal of any NMR active nucleus might provide new perspectives for hyperpolarized 129Xe NMR/MRI. Initial publications about 129Xe DNP underlined the increased complexity in the sample preparation and lower polarization levels when compared to more conventional 13C-labeled molecules, at same experimental conditions, despite very close gyromagnetic ratios. Herein, we introduce, using a Custom Fluid Path system, a user-friendly and very robust sample preparation method. Moreover, investigating the radical properties at real DNP conditions by means of LOngitudinal Detected Electron Spin Resonance, we discovered a dramatic shortening of the electron spin longitudinal relaxation time (T1e) of nitroxyl radicals in xenon DNP samples' matrices, with respect to more commonly used water:glycerol ones. Mitigating those challenges through microwave frequency modulation, we achieved over 20% 129Xe polarization without employing any deuterated solvent.
Collapse
Affiliation(s)
- Emma Wiström
- LIFMET,
Institute of Physics, École Polytechnique
Fédérale de Lausanne (EPFL), Station 6, 1015 Lausanne, Switzerland
| | - Jean-Noël Hyacinthe
- LIFMET,
Institute of Physics, École Polytechnique
Fédérale de Lausanne (EPFL), Station 6, 1015 Lausanne, Switzerland
| | - Thanh Phong Lê
- LIFMET,
Institute of Physics, École Polytechnique
Fédérale de Lausanne (EPFL), Station 6, 1015 Lausanne, Switzerland
| | - Rolf Gruetter
- LIFMET,
Institute of Physics, École Polytechnique
Fédérale de Lausanne (EPFL), Station 6, 1015 Lausanne, Switzerland
| | - Andrea Capozzi
- LIFMET,
Institute of Physics, École Polytechnique
Fédérale de Lausanne (EPFL), Station 6, 1015 Lausanne, Switzerland
- HYPERMAG,
Department of Health Technology, Technical
University of Denmark, Building 349, 2800 Kgs Lyngby, Denmark
| |
Collapse
|
2
|
Foo CT, Langton D, Thompson BR, Thien F. Functional lung imaging using novel and emerging MRI techniques. Front Med (Lausanne) 2023; 10:1060940. [PMID: 37181360 PMCID: PMC10166823 DOI: 10.3389/fmed.2023.1060940] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Accepted: 04/03/2023] [Indexed: 05/16/2023] Open
Abstract
Respiratory diseases are leading causes of death and disability in the world. While early diagnosis is key, this has proven difficult due to the lack of sensitive and non-invasive tools. Computed tomography is regarded as the gold standard for structural lung imaging but lacks functional information and involves significant radiation exposure. Lung magnetic resonance imaging (MRI) has historically been challenging due to its short T2 and low proton density. Hyperpolarised gas MRI is an emerging technique that is able to overcome these difficulties, permitting the functional and microstructural evaluation of the lung. Other novel imaging techniques such as fluorinated gas MRI, oxygen-enhanced MRI, Fourier decomposition MRI and phase-resolved functional lung imaging can also be used to interrogate lung function though they are currently at varying stages of development. This article provides a clinically focused review of these contrast and non-contrast MR imaging techniques and their current applications in lung disease.
Collapse
Affiliation(s)
- Chuan T. Foo
- Department of Respiratory Medicine, Eastern Health, Melbourne, VIC, Australia
- Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, VIC, Australia
| | - David Langton
- Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, VIC, Australia
- Department of Thoracic Medicine, Peninsula Health, Frankston, VIC, Australia
| | - Bruce R. Thompson
- Melbourne School of Health Science, Melbourne University, Melbourne, VIC, Australia
| | - Francis Thien
- Department of Respiratory Medicine, Eastern Health, Melbourne, VIC, Australia
- Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, VIC, Australia
| |
Collapse
|
3
|
Perron S, Ouriadov A. Hyperpolarized 129Xe MRI at low field: Current status and future directions. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 348:107387. [PMID: 36731353 DOI: 10.1016/j.jmr.2023.107387] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 12/07/2022] [Accepted: 01/23/2023] [Indexed: 06/18/2023]
Abstract
Magnetic Resonance Imaging (MRI) is dictated by the magnetization of the sample, and is thus a low-sensitivity imaging method. Inhalation of hyperpolarized (HP) noble gases, such as helium-3 and xenon-129, is a non-invasive, radiation-risk free imaging technique permitting high resolution imaging of the lungs and pulmonary functions, such as the lung microstructure, diffusion, perfusion, gas exchange, and dynamic ventilation. Instead of increasing the magnetic field strength, the higher spin polarization achievable from this method results in significantly higher net MR signal independent of tissue/water concentration. Moreover, the significantly longer apparent transverse relaxation time T2* of these HP gases at low magnetic field strengths results in fewer necessary radiofrequency (RF) pulses, permitting larger flip angles; this allows for high-sensitivity imaging of in vivo animal and human lungs at conventionally low (<0.5 T) field strengths and suggests that the low field regime is optimal for pulmonary MRI using hyperpolarized gases. In this review, theory on the common spin-exchange optical-pumping method of hyperpolarization and the field dependence of the MR signal of HP gases are presented, in the context of human lung imaging. The current state-of-the-art is explored, with emphasis on both MRI hardware (low field scanners, RF coils, and polarizers) and image acquisition techniques (pulse sequences) advancements. Common challenges surrounding imaging of HP gases and possible solutions are discussed, and the future of low field hyperpolarized gas MRI is posed as being a clinically-accessible and versatile imaging method, circumventing the siting restrictions of conventional high field scanners and bringing point-of-care pulmonary imaging to global facilities.
Collapse
Affiliation(s)
- Samuel Perron
- Department of Physics and Astronomy, The University of Western Ontario, London, Ontario, Canada.
| | - Alexei Ouriadov
- Department of Physics and Astronomy, The University of Western Ontario, London, Ontario, Canada; Lawson Health Research Institute, London, Ontario, Canada; School of Biomedical Engineering, Faculty of Engineering, The University of Western Ontario, London, Ontario, Canada
| |
Collapse
|
4
|
Kelley M, Branca RT. A simple setup for in situ alkali metal electronic spin polarimetry. AIP ADVANCES 2022; 12:095307. [PMID: 36110253 PMCID: PMC9470229 DOI: 10.1063/5.0101537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 07/12/2022] [Indexed: 06/15/2023]
Abstract
Faraday rotation is considered a gold standard measurement of the electronic spin polarization of an alkali metal vapor produced under optical pumping. However, during the production of large volumes of hyperpolarized xenon gas, transmission monitoring measurements, otherwise known as field cycling measurements, are generally employed to measure the spin polarization of alkali metal atoms in situ as this method is easier to implement than Faraday rotation on standard polarizer setups. Here, we present a simple, low-cost experimental setup to perform Faraday rotation measurements of the electronic spin polarization of alkali metal atoms that can be easily implemented on standard polarizer setups. We then compare Rb polarization measurements obtained with the Faraday rotation method to those obtained with the transmission monitoring method. To our knowledge, a direct comparison of these methods has never been made. Overall, we found good agreement between the two methods, but at low Rb density and high laser power, we found evidence of nonlinear magneto-optical effects that may prevent Faraday rotation from being used under these conditions.
Collapse
Affiliation(s)
| | - R. T. Branca
- Author to whom correspondence should be addressed:
| |
Collapse
|
5
|
DOĞANAY Ö. Computational investigation of fitting for calculation of signal dynamics from hyperpolarized xenon-129 Gas MRI. EGE TIP DERGISI 2022. [DOI: 10.19161/etd.1085607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
6
|
Pilot Quality-Assurance Study of a Third-Generation Batch-Mode Clinical-Scale Automated Xenon-129 Hyperpolarizer. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27041327. [PMID: 35209116 PMCID: PMC8879294 DOI: 10.3390/molecules27041327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 02/08/2022] [Accepted: 02/10/2022] [Indexed: 11/28/2022]
Abstract
We present a pilot quality assurance (QA) study of a clinical-scale, automated, third-generation (GEN-3) 129Xe hyperpolarizer employing batch-mode spin-exchange optical pumping (SEOP) with high-Xe densities (50% natural abundance Xe and 50% N2 in ~2.6 atm total pressure sourced from Nova Gas Technologies) and rapid temperature ramping enabled by an aluminum heating jacket surrounding the 0.5 L SEOP cell. 129Xe hyperpolarization was performed over the course of 700 gas loading cycles of the SEOP cell, simulating long-term hyperpolarized contrast agent production in a clinical lung imaging setting. High levels of 129Xe polarization (avg. %PXe = 51.0% with standard deviation σPXe = 3.0%) were recorded with fast 129Xe polarization build-up time constants (avg. Tb = 25.1 min with standard deviation σTb = 3.1 min) across the first 500 SEOP cell refills, using moderate temperatures of 75 °C. These results demonstrate a more than 2-fold increase in build-up rate relative to previously demonstrated results in a comparable QA study on a second-generation (GEN-2) 129Xe hyperpolarizer device, with only a minor reduction in maximum achievable %PXe and with greater consistency over a larger number of SEOP cell refill processes at a similar polarization lifetime duration (avg. T1 = 82.4 min, standard deviation σT1 = 10.8 min). Additionally, the effects of varying SEOP jacket temperatures, distribution of Rb metal, and preparation and operation of the fluid path are quantified in the context of device installation, performance optimization and maintenance to consistently produce high 129Xe polarization values, build-up rates (Tb as low as 6 min) and lifetimes over the course of a typical high-throughput 129Xe polarization SEOP cell life cycle. The results presented further demonstrate the significant potential for hyperpolarized 129Xe contrast agent in imaging and bio-sensing applications on a clinical scale.
Collapse
|
7
|
Khan AS, Harvey RL, Birchall JR, Irwin RK, Nikolaou P, Schrank G, Emami K, Dummer A, Barlow MJ, Goodson BM, Chekmenev EY. Enabling Clinical Technologies for Hyperpolarized 129 Xenon Magnetic Resonance Imaging and Spectroscopy. Angew Chem Int Ed Engl 2021; 60:22126-22147. [PMID: 34018297 PMCID: PMC8478785 DOI: 10.1002/anie.202015200] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Indexed: 11/06/2022]
Abstract
Hyperpolarization is a technique that can increase nuclear spin polarization with the corresponding gains in nuclear magnetic resonance (NMR) signals by 4-8 orders of magnitude. When this process is applied to biologically relevant samples, the hyperpolarized molecules can be used as exogenous magnetic resonance imaging (MRI) contrast agents. A technique called spin-exchange optical pumping (SEOP) can be applied to hyperpolarize noble gases such as 129 Xe. Techniques based on hyperpolarized 129 Xe are poised to revolutionize clinical lung imaging, offering a non-ionizing, high-contrast alternative to computed tomography (CT) imaging and conventional proton MRI. Moreover, CT and conventional proton MRI report on lung tissue structure but provide little functional information. On the other hand, when a subject breathes hyperpolarized 129 Xe gas, functional lung images reporting on lung ventilation, perfusion and diffusion with 3D readout can be obtained in seconds. In this Review, the physics of SEOP is discussed and the different production modalities are explained in the context of their clinical application. We also briefly compare SEOP to other hyperpolarization methods and conclude this paper with the outlook for biomedical applications of hyperpolarized 129 Xe to lung imaging and beyond.
Collapse
Affiliation(s)
- Alixander S Khan
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Rebecca L Harvey
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Jonathan R Birchall
- Intergrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), 5101 Cass Avenue, Detroit, MI, 48202, USA
| | - Robert K Irwin
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, NG7 2RD, UK
| | | | - Geoffry Schrank
- Northrup Grumman Space Systems, 45101 Warp Drive, Sterling, VA, 20166, USA
| | | | | | - Michael J Barlow
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Boyd M Goodson
- Department of Chemistry and Biochemistry, Southern Illinois University, 1245 Lincoln Drive, Carbondale, IL, 62901, USA
- Materials Technology Center, Southern Illinois University, 1245 Lincoln Drive, Carbondale, IL, 62901, USA
| | - Eduard Y Chekmenev
- Intergrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), 5101 Cass Avenue, Detroit, MI, 48202, USA
- Russian Academy of Sciences, Leninskiy Prospekt 14, Moscow, 119991, Russia
| |
Collapse
|
8
|
Khan AS, Harvey RL, Birchall JR, Irwin RK, Nikolaou P, Schrank G, Emami K, Dummer A, Barlow MJ, Goodson BM, Chekmenev EY. Enabling Clinical Technologies for Hyperpolarized
129
Xenon Magnetic Resonance Imaging and Spectroscopy. Angew Chem Int Ed Engl 2021. [DOI: 10.1002/ange.202015200] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Alixander S. Khan
- Sir Peter Mansfield Imaging Centre University of Nottingham Nottingham NG7 2RD UK
| | - Rebecca L. Harvey
- Sir Peter Mansfield Imaging Centre University of Nottingham Nottingham NG7 2RD UK
| | - Jonathan R. Birchall
- Intergrative Biosciences (Ibio) Wayne State University, Karmanos Cancer Institute (KCI) 5101 Cass Avenue Detroit MI 48202 USA
| | - Robert K. Irwin
- Sir Peter Mansfield Imaging Centre University of Nottingham Nottingham NG7 2RD UK
| | | | - Geoffry Schrank
- Northrup Grumman Space Systems 45101 Warp Drive Sterling VA 20166 USA
| | | | | | - Michael J. Barlow
- Sir Peter Mansfield Imaging Centre University of Nottingham Nottingham NG7 2RD UK
| | - Boyd M. Goodson
- Department of Chemistry and Biochemistry Southern Illinois University 1245 Lincoln Drive Carbondale IL 62901 USA
- Materials Technology Center Southern Illinois University 1245 Lincoln Drive Carbondale IL 62901 USA
| | - Eduard Y. Chekmenev
- Intergrative Biosciences (Ibio) Wayne State University, Karmanos Cancer Institute (KCI) 5101 Cass Avenue Detroit MI 48202 USA
- Russian Academy of Sciences Leninskiy Prospekt 14 Moscow 119991 Russia
| |
Collapse
|
9
|
Lee WT, Zheng G, Talbot CL, Tong X, D'Adam T, Parnell SR, de Veer M, Jenkin G, Polglase GR, Hooper SB, Thompson BR, Thien F, Egan GF. Hyperpolarised gas filling station for medical imaging using polarised 129Xe and 3He. Magn Reson Imaging 2021; 79:112-120. [PMID: 33600894 PMCID: PMC7882919 DOI: 10.1016/j.mri.2021.02.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 02/12/2021] [Accepted: 02/12/2021] [Indexed: 11/25/2022]
Abstract
We report the design, construction, and initial tests of a hyperpolariser to produce polarised 129Xe and 3He gas for medical imaging of the lung. The hyperpolariser uses the Spin-Exchange Optical Pumping method to polarise the nuclear spins of the isotopic gas. Batch mode operation was chosen for the design to produce polarised 129Xe and polarised 3He. Two-side pumping, electrical heating and a piston to transfer the polarised gas were some of the implemented techniques that are not commonly used in hyperpolariser designs. We have carried out magnetic resonance imaging experiments demonstrating that the 3He and 129Xe polarisation reached were sufficient for imaging, in particular for in vivo lung imaging using 129Xe. Further improvements to the hyperpolariser have also been discussed.
Collapse
Affiliation(s)
- Wai Tung Lee
- Australia Nuclear Science and Technology Organization, Lucas Heights, New South Wales 2234, Australia.
| | - Gang Zheng
- Monash Biomedical Imaging, Monash University, Melbourne, Victoria 3800, Australia
| | - Cavin L Talbot
- University of Queensland, St Lucia, Queensland 4072, Australia
| | - Xin Tong
- Spallation Neutron Source Science Center, Dongguan, 523803, China; Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
| | - Tim D'Adam
- Australia Nuclear Science and Technology Organization, Lucas Heights, New South Wales 2234, Australia
| | - Steven R Parnell
- Delft University of Technology, Mekelweg 15, 2629 JB, Delft, the Netherlands
| | - Michael de Veer
- Monash Biomedical Imaging, Monash University, Melbourne, Victoria 3800, Australia
| | - Graham Jenkin
- The Ritchie Centre, Monash University and Hudson Institute of Medical Research, Clayton, Victoria 3168, Australia
| | - Graeme R Polglase
- The Ritchie Centre, Monash University and Hudson Institute of Medical Research, Clayton, Victoria 3168, Australia; Department of Obstetrics and Gynaecology, Monash University, Clayton, Victoria 3168, Australia
| | - Stuart B Hooper
- The Ritchie Centre, Monash University and Hudson Institute of Medical Research, Clayton, Victoria 3168, Australia; Department of Obstetrics and Gynaecology, Monash University, Clayton, Victoria 3168, Australia
| | - Bruce R Thompson
- Swinburne University of Technology, Hawthorne, Victoria 3122, Australia
| | - Francis Thien
- Eastern Health Clinical School, Monash University, Clayton, Victoria 3168, Australia
| | - Gary F Egan
- Monash Biomedical Imaging, Monash University, Melbourne, Victoria 3800, Australia
| |
Collapse
|
10
|
Birchall JR, Coffey AM, Goodson BM, Chekmenev EY. High-Pressure Clinical-Scale 87% Parahydrogen Generator. Anal Chem 2020; 92:15280-15284. [DOI: 10.1021/acs.analchem.0c03358] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Jonathan R. Birchall
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, Michigan 48202, United States
| | - Aaron M. Coffey
- Department of Radiology, Vanderbilt University Institute of Imaging Science (VUIIS), Nashville, Tennessee 37232, United States
| | | | - Eduard Y. Chekmenev
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, Michigan 48202, United States
- Russian Academy of Sciences, Leninskiy Prospekt 14, Moscow 119991, Russia
| |
Collapse
|
11
|
Plummer JW, Emami K, Dummer A, Woods JC, Walkup LL, Cleveland ZI. A semi-empirical model to optimize continuous-flow hyperpolarized 129Xe production under practical cryogenic-accumulation conditions. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 320:106845. [PMID: 33070086 PMCID: PMC7655637 DOI: 10.1016/j.jmr.2020.106845] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2020] [Revised: 10/02/2020] [Accepted: 10/04/2020] [Indexed: 05/05/2023]
Abstract
Continuous-flow spin exchange optical pumping (SEOP) with cryogenic accumulation is a powerful technique to generate multiple, large volumes of hyperpolarized (HP) 129Xe in rapid succession. It enables a range of studies, from dark matter tracking to preclinical and clinical MRI. Multiple analytical models based on first principles atomic physics and device-specific design features have been proposed for individual processes within HP 129Xe production. However, the modeling efforts have not yet integrated all the steps involved in practical, large volume HP 129Xe production process (e.g., alkali vapor generation, continuous-flow SEOP, and cryogenic accumulation). Here, we use a simplified analytical model that couples both SEOP and cryogenic accumulation, incorporating only two system-specific empirical parameters: the longitudinal relaxation time of the polycrystalline 129Xe "snow', T1snow, generated during cryogenic accumulation, and 2) the average Rb density during active, continuous-flow polarization. By fitting the model to polarization data collected from >140 L of 129Xe polarized across a range of flow and volume conditions, the estimates for Rb density and T1snow were 1.6 ± 0.1 × 1013 cm-3 and 84 ± 5 min, respectively - each notably less than expected based on previous literature. Together, these findings indicate that 1) earlier polarization predictions were hindered by miscalculated Rb densities, and 2) polarization is not optimized by maximizing SEOP efficiency with a low concentration 129Xe, but rather by using richer 129Xe-buffer gas blends that enable faster accumulation. Accordingly, modeling and experimentation revealed the optimal fraction of 129Xe, f, in the 129Xe-buffer gas blend was ~2%. Further, if coupled with modest increases in laser power, the model predicts liter volumes of HP 129Xe with polarizations exceeding 60% could be generated routinely in only tens of minutes.
Collapse
Affiliation(s)
- Joseph W Plummer
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, United States; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States
| | | | | | - Jason C Woods
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, United States; Department of Pediatrics, University of Cincinnati, Cincinnati, OH, United States
| | - Laura L Walkup
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, United States; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States; Department of Pediatrics, University of Cincinnati, Cincinnati, OH, United States
| | - Zackary I Cleveland
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, United States; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, United States; Department of Pediatrics, University of Cincinnati, Cincinnati, OH, United States.
| |
Collapse
|
12
|
Jayapaul J, Schröder L. Molecular Sensing with Host Systems for Hyperpolarized 129Xe. Molecules 2020; 25:E4627. [PMID: 33050669 PMCID: PMC7587211 DOI: 10.3390/molecules25204627] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 09/27/2020] [Accepted: 09/30/2020] [Indexed: 12/12/2022] Open
Abstract
Hyperpolarized noble gases have been used early on in applications for sensitivity enhanced NMR. 129Xe has been explored for various applications because it can be used beyond the gas-driven examination of void spaces. Its solubility in aqueous solutions and its affinity for hydrophobic binding pockets allows "functionalization" through combination with host structures that bind one or multiple gas atoms. Moreover, the transient nature of gas binding in such hosts allows the combination with another signal enhancement technique, namely chemical exchange saturation transfer (CEST). Different systems have been investigated for implementing various types of so-called Xe biosensors where the gas binds to a targeted host to address molecular markers or to sense biophysical parameters. This review summarizes developments in biosensor design and synthesis for achieving molecular sensing with NMR at unprecedented sensitivity. Aspects regarding Xe exchange kinetics and chemical engineering of various classes of hosts for an efficient build-up of the CEST effect will also be discussed as well as the cavity design of host molecules to identify a pool of bound Xe. The concept is presented in the broader context of reporter design with insights from other modalities that are helpful for advancing the field of Xe biosensors.
Collapse
Affiliation(s)
| | - Leif Schröder
- Molecular Imaging, Leibniz-Forschungsinstitut für Molekulare Pharmakologie (FMP), 13125 Berlin, Germany;
| |
Collapse
|
13
|
Birchall JR, Irwin RK, Nikolaou P, Coffey AM, Kidd BE, Murphy M, Molway M, Bales LB, Ranta K, Barlow MJ, Goodson BM, Rosen MS, Chekmenev EY. XeUS: A second-generation automated open-source batch-mode clinical-scale hyperpolarizer. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 319:106813. [PMID: 32932118 DOI: 10.1016/j.jmr.2020.106813] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 08/20/2020] [Accepted: 08/24/2020] [Indexed: 06/11/2023]
Abstract
We present a second-generation open-source automated batch-mode 129Xe hyperpolarizer (XeUS GEN-2), designed for clinical-scale hyperpolarized (HP) 129Xe production via spin-exchange optical pumping (SEOP) in the regimes of high Xe density (0.66-2.5 atm partial pressure) and resonant photon flux (~170 W, Δλ = 0.154 nm FWHM), without the need for cryo-collection typically employed by continuous-flow hyperpolarizers. An Arduino micro-controller was used for hyperpolarizer operation. Processing open-source software was employed to program a custom graphical user interface (GUI), capable of remote automation. The Arduino Integrated Development Environment (IDE) was used to design a variety of customized automation sequences such as temperature ramping, NMR signal acquisition, and SEOP cell refilling for increased reliability. A polycarbonate 3D-printed oven equipped with a thermo-electric cooler/heater provides thermal stability for SEOP for both binary (Xe/N2) and ternary (4He-containing) SEOP cell gas mixtures. Quantitative studies of the 129Xe hyperpolarization process demonstrate that near-unity polarization can be achieved in a 0.5 L SEOP cell. For example, %PXe of 93.2 ± 2.9% is achieved at 0.66 atm Xe pressure with polarization build-up rate constant γSEOP = 0.040 ± 0.005 min-1, giving a max dose equivalent ≈ 0.11 L/h 100% hyperpolarized, 100% enriched 129Xe; %PXe of 72.6 ± 1.4% is achieved at 1.75 atm Xe pressure with γSEOP of 0.041 ± 0.001 min-1, yielding a corresponding max dose equivalent of 0.27 L/h. Quality assurance studies on this device have demonstrated the potential to refill SEOP cells hundreds of times without significant losses in performance, with average %PXe = 71.7%, (standard deviation σP = 1.52%) and mean polarization lifetime T1 = 90.5 min, (standard deviation σT = 10.3 min) over the first ~200 gas mixture refills, with sufficient performance maintained across a further ~700 refills. These findings highlight numerous technological developments and have significant translational relevance for efficient production of gaseous HP 129Xe contrast agents for use in clinical imaging and bio-sensing techniques.
Collapse
Affiliation(s)
- Jonathan R Birchall
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, MI 48202, United States
| | - Robert K Irwin
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | | | - Aaron M Coffey
- Department of Radiology, Vanderbilt University Institute of Imaging Science (VUIIS), Nashville, TN 37232, United States
| | - Bryce E Kidd
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States
| | - Megan Murphy
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States
| | - Michael Molway
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States
| | - Liana B Bales
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States
| | - Kaili Ranta
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States
| | - Michael J Barlow
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | - Boyd M Goodson
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States; Materials Technology Center, Southern Illinois University, Carbondale, IL 62901, United States
| | - Matthew S Rosen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA 02129, United States; Department of Physics, Harvard University, Cambridge, MA 02138, United States
| | - Eduard Y Chekmenev
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, MI 48202, United States; Russian Academy of Sciences, Leninskiy Prospekt 14, Moscow 119991, Russia.
| |
Collapse
|
14
|
Birchall JR, Irwin RK, Nikolaou P, Pokochueva EV, Kovtunov KV, Koptyug IV, Barlow MJ, Goodson BM, Chekmenev EY. Pilot multi-site quality assurance study of batch-mode clinical-scale automated xenon-129 hyperpolarizers. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 316:106755. [PMID: 32512397 DOI: 10.1016/j.jmr.2020.106755] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 05/21/2020] [Accepted: 05/25/2020] [Indexed: 06/11/2023]
Abstract
We present a pilot quality assurance (QA) study of spin-exchange optical pumping (SEOP) performed on two nearly identical second-generation (GEN-2) automated batch-mode clinical-scale 129Xe hyperpolarizers, each utilizing a convective forced air oven, high-power (~170 W) continuous pump laser irradiation, and xenon-rich gas mixtures (~1.30 atm partial pressure). In one study, the repeatability of SEOP in a 1000 Torr Xe/900 Torr N2/100 Torr 4He (2000 Torr total pressure) gas mixture is evaluated over the course of ~700 gas loading cycles, with negligible decrease in performance during the first ~200 cycles, and with high 129Xe polarization levels (avg. %PXe = 71.7% with standard deviation σPXe = 1.5%), build-up rates (avg. γSEOP = 0.019 min-1 with standard deviation σγ = 0.003 min-1) and polarization lifetimes (avg. T1 = 90.5 min with standard deviation σT = 10.3 min) reported at moderate oven temperature of ~70 °C. Although the SEOP cell in this study exhibited a detectable performance decrease after 400 cycles, the cell continued to produce potentially useable HP 129Xe with %PXe = 42.3 ± 0.6% even after nearly 700 refill cycles. The possibility of "regenerating" "dormant" (i.e., not used for an extended period of time) SEOP cells using repeated temperature cycling methods to recover %PXe is also demonstrated. The quality and consistency of results show significant promise for translation to clinical-scale production of hyperpolarized 129Xe contrast agents for imaging and bio-sensing applications.
Collapse
Affiliation(s)
- Jonathan R Birchall
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, MI 48202, United States.
| | - Robert K Irwin
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | | | - Ekaterina V Pokochueva
- International Tomography Center SB RAS, Institutskaya Street 3A, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova Street 2, Novosibirsk 630090, Russia
| | - Kirill V Kovtunov
- International Tomography Center SB RAS, Institutskaya Street 3A, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova Street 2, Novosibirsk 630090, Russia
| | - Igor V Koptyug
- International Tomography Center SB RAS, Institutskaya Street 3A, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova Street 2, Novosibirsk 630090, Russia
| | - Michael J Barlow
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | - Boyd M Goodson
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States; Materials Technology Center, Southern Illinois University, Carbondale, IL 62901, United States
| | - Eduard Y Chekmenev
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, MI 48202, United States; Russian Academy of Sciences, Leninskiy Prospekt 14, Moscow 119991, Russia.
| |
Collapse
|
15
|
Birchall JR, Nikolaou P, Irwin RK, Barlow MJ, Ranta K, Coffey AM, Goodson BM, Pokochueva EV, Kovtunov KV, Koptyug IV, Chekmenev EY. Helium-rich mixtures for improved batch-mode clinical-scale spin-exchange optical pumping of Xenon-129. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 315:106739. [PMID: 32408239 DOI: 10.1016/j.jmr.2020.106739] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 04/24/2020] [Indexed: 06/11/2023]
Abstract
We present studies of spin-exchange optical pumping (SEOP) using ternary xenon-nitrogen-helium gas mixtures at high xenon partial pressures (up to 1330 Torr partial pressure at loading, out of 2660 Torr total pressure) in a 500-mL volume SEOP cell, using two automated batch-mode clinical-scale 129Xe hyperpolarizers operating under continuous high-power (~170 W) pump laser irradiation. In this pilot study, we explore SEOP in gas mixtures with up to 45% 4He content under a wide range of experimental conditions. When an aluminum jacket cooling/heating design was employed (GEN-3 hyperpolarizer), 129Xe polarization (%PXe) of 55.9 ± 0.9% was observed with mono-exponential build-up rate γSEOP of 0.049 ± 0.001 min-1 for the 4He-rich mixture (1000 Torr Xe/900 Torr He, 100 Torr N2), compared to %PXe of 49.3 ± 3.3% at γSEOP of 0.035 ± 0.004 min-1 for the N2-rich gas mixture (1000 Torr Xe/100 Torr He, 900 Torr N2). When forced-air cooling/heating was used (GEN-2 hyperpolarizer), %PXe of 83.9 ± 2.7% was observed at γSEOP of 0.045 ± 0.005 min-1 for the 4He-rich mixture (1000 Torr Xe/900 Torr He, 100 Torr N2), compared to %PXe of 73.5 ± 1.3% at γSEOP of 0.028 ± 0.001 min-1 for the N2-rich gas mixture (1000 Torr Xe and 1000 Torr N2). Additionally, %PXe of 72.6 ± 1.4% was observed at a build-up rate γSEOP of 0.041 ± 0.003 min-1 for a super-high-density 4He-rich mixture (1330 Torr Xe/1200 Torr 4He/130 Torr N2), compared to %PXe = 56.6 ± 1.3% at a build-up rate of γSEOP of 0.034 ± 0.002 min-1 for an N2-rich mixture (1330 Torr Xe/1330 Torr N2) using forced air cooling/heating. The observed SEOP hyperpolarization performance under these conditions corresponds to %PXe improvement by a factor of 1.14 ± 0.04 at 1000 Torr Xe density and by up to a factor of 1.28 ± 0.04 at 1330 Torr Xe density at improved SEOP build-up rates by factors of 1.61 ± 0.18 and 1.21 ± 0.11 respectively. Record %PXe levels have been obtained here: 83.9 ± 2.7% at 1000 Torr Xe partial pressure and 72.6 ± 1.4% at 1330 Torr Xe partial pressure. In addition to improved thermal stability for SEOP, the use of 4He-rich gas mixtures also reduces the overall density of produced inhalable HP contrast agents; this property may be desirable for HP 129Xe inhalation by human subjects in clinical settings-especially in populations with heavily impaired lung function. The described approach should enjoy ready application in the production of inhalable 129Xe contrast agent with near-unity 129Xe nuclear spin polarization.
Collapse
Affiliation(s)
- Jonathan R Birchall
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), 5101 Cass Ave, Detroit, MI 48202, United States
| | | | - Robert K Irwin
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | - Michael J Barlow
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | - Kaili Ranta
- Department of Chemistry and Biochemistry, Southern Illinois University, 1245 Lincoln Drive, Carbondale, IL 62901, United States
| | - Aaron M Coffey
- Department of Radiology, Vanderbilt University Institute of Imaging Science (VUIIS), 1161 21st Ave South, Nashville, TN 37232, United States
| | - Boyd M Goodson
- Department of Chemistry and Biochemistry, Southern Illinois University, 1245 Lincoln Drive, Carbondale, IL 62901, United States; Materials Technology Center, Southern Illinois University, 1245 Lincoln Drive, Carbondale, IL 62901, United States
| | - Ekaterina V Pokochueva
- International Tomography Center SB RAS, Institutskaya Street 3A, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova Street 2, Novosibirsk 630090, Russia
| | - Kirill V Kovtunov
- International Tomography Center SB RAS, Institutskaya Street 3A, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova Street 2, Novosibirsk 630090, Russia
| | - Igor V Koptyug
- International Tomography Center SB RAS, Institutskaya Street 3A, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova Street 2, Novosibirsk 630090, Russia
| | - Eduard Y Chekmenev
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), 5101 Cass Ave, Detroit, MI 48202, United States; Russian Academy of Sciences, Leninskiy Prospekt 14, Moscow 119991, Russia.
| |
Collapse
|
16
|
Birchall JR, Nikolaou P, Coffey AM, Kidd BE, Murphy M, Molway M, Bales LB, Goodson BM, Irwin RK, Barlow MJ, Chekmenev EY. Batch-Mode Clinical-Scale Optical Hyperpolarization of Xenon-129 Using an Aluminum Jacket with Rapid Temperature Ramping. Anal Chem 2020; 92:4309-4316. [PMID: 32073251 DOI: 10.1021/acs.analchem.9b05051] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
We present spin-exchange optical pumping (SEOP) using a third-generation (GEN-3) automated batch-mode clinical-scale 129Xe hyperpolarizer utilizing continuous high-power (∼170 W) pump laser irradiation and a novel aluminum jacket design for rapid temperature ramping of xenon-rich gas mixtures (up to 2 atm partial pressure). The aluminum jacket design is capable of heating SEOP cells from ambient temperature (typically 25 °C) to 70 °C (temperature of the SEOP process) in 4 min, and perform cooling of the cell to the temperature at which the hyperpolarized gas mixture can be released from the hyperpolarizer (with negligible amounts of Rb metal leaving the cell) in approximately 4 min, substantially faster (by a factor of 6) than previous hyperpolarizer designs relying on air heat exchange. These reductions in temperature cycling time will likely be highly advantageous for the overall increase of production rates of batch-mode (i.e., stopped-flow) 129Xe hyperpolarizers, which is particularly beneficial for clinical applications. The additional advantage of the presented design is significantly improved thermal management of the SEOP cell. Accompanying the heating jacket design and performance, we also evaluate the repeatability of SEOP experiments conducted using this new architecture, and present typically achievable hyperpolarization levels exceeding 40% at exponential build-up rates on the order of 0.1 min-1.
Collapse
Affiliation(s)
- Jonathan R Birchall
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, Michigan 48202, United States
| | | | - Aaron M Coffey
- Department of Radiology, Vanderbilt University Institute of Imaging Science (VUIIS), Nashville, Tennessee 37232, United States
| | | | | | | | | | | | - Robert K Irwin
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, NG7 2RD, United Kingdom
| | - Michael J Barlow
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, NG7 2RD, United Kingdom
| | - Eduard Y Chekmenev
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, Michigan 48202, United States.,Russian Academy of Sciences, Leninskiy Prospekt 14, Moscow, 119991, Russia
| |
Collapse
|
17
|
Skinner JG, Ranta K, Whiting N, Coffey AM, Nikolaou P, Rosen MS, Chekmenev EY, Morris PG, Barlow MJ, Goodson BM. High Xe density, high photon flux, stopped-flow spin-exchange optical pumping: Simulations versus experiments. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 312:106686. [PMID: 32006793 PMCID: PMC7436892 DOI: 10.1016/j.jmr.2020.106686] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Accepted: 01/07/2020] [Indexed: 05/13/2023]
Abstract
Spin-exchange optical pumping (SEOP) can enhance the NMR sensitivity of noble gases by up to five orders of magnitude at Tesla-strength magnetic fields. SEOP-generated hyperpolarised (HP) 129Xe is a promising contrast agent for lung imaging but an ongoing barrier to widespread clinical usage has been economical production of sufficient quantities with high 129Xe polarisation. Here, the 'standard model' of SEOP, which was previously used in the optimisation of continuous-flow 129Xe polarisers, is modified for validation against two Xe-rich stopped-flow SEOP datasets. We use this model to examine ways to increase HP Xe production efficiency in stopped-flow 129Xe polarisers and provide further insight into the underlying physics of Xe-rich stopped-flow SEOP at high laser fluxes.
Collapse
Affiliation(s)
- Jason G Skinner
- Division of Respiratory Medicine, School of Medicine, Queen's Medical Centre, University of Nottingham, Nottingham, NG7 2UH, UK
| | - Kaili Ranta
- Department of Chemistry and Biochemistry, Southern Illinois University Carbondale, Carbondale, IL, 62901, USA
| | - Nicholas Whiting
- Department of Physics & Astronomy and Department of Molecular & Cellular Biosciences, Rowan University, Glassboro, NJ 08028, USA
| | - Aaron M Coffey
- Vanderbilt University Institute of Imaging Science (VUIIS), Department of Radiology and Radiological Sciences, Vanderbilt-Ingram Cancer Center (VICC), Department of Biomedical Engineering, Department of Physics and Astronomy, Vanderbilt University Medical Center, Nashville, TN, 37232, USA
| | | | - Matthew S Rosen
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, 149 13th Street, Charlestown, MA 02129, USA; Department of Radiology, Harvard Medical School, Boston, MA 02115, USA; Department of Physics, Harvard University, Cambridge, MA 02138, USA
| | - Eduard Y Chekmenev
- Russian Academy of Sciences, Leninskiy Prospekt 14, 119991 Moscow, Russia; Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, MI, 48202, United States
| | - Peter G Morris
- Sir Peter Mansfield Imaging Centre, School of Physics & Astronomy, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Michael J Barlow
- Division of Respiratory Medicine, School of Medicine, Queen's Medical Centre, University of Nottingham, Nottingham, NG7 2UH, UK
| | - Boyd M Goodson
- Department of Chemistry and Biochemistry, Southern Illinois University Carbondale, Carbondale, IL, 62901, USA.
| |
Collapse
|
18
|
Jayapaul J, Schröder L. Nanoparticle-Based Contrast Agents for 129Xe HyperCEST NMR and MRI Applications. CONTRAST MEDIA & MOLECULAR IMAGING 2019; 2019:9498173. [PMID: 31819739 PMCID: PMC6893250 DOI: 10.1155/2019/9498173] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Accepted: 10/15/2019] [Indexed: 02/06/2023]
Abstract
Spin hyperpolarization techniques have enabled important advancements in preclinical and clinical MRI applications to overcome the intrinsic low sensitivity of nuclear magnetic resonance. Functionalized xenon biosensors represent one of these approaches. They combine two amplification strategies, namely, spin exchange optical pumping (SEOP) and chemical exchange saturation transfer (CEST). The latter one requires host structures that reversibly bind the hyperpolarized noble gas. Different nanoparticle approaches have been implemented and have enabled molecular MRI with 129Xe at unprecedented sensitivity. This review gives an overview of the Xe biosensor concept, particularly how different nanoparticles address various critical aspects of gas binding and exchange, spectral dispersion for multiplexing, and targeted reporter delivery. As this concept is emerging into preclinical applications, comprehensive sensor design will be indispensable in translating the outstanding sensitivity potential into biomedical molecular imaging applications.
Collapse
Affiliation(s)
- Jabadurai Jayapaul
- Molecular Imaging, Leibniz-Forschungsinstitut für Molekulare Pharmakologie (FMP), 13125 Berlin, Germany
| | - Leif Schröder
- Molecular Imaging, Leibniz-Forschungsinstitut für Molekulare Pharmakologie (FMP), 13125 Berlin, Germany
| |
Collapse
|
19
|
Rayner PJ, Tickner BJ, Iali W, Fekete M, Robinson AD, Duckett SB. Relayed hyperpolarization from para-hydrogen improves the NMR detectability of alcohols. Chem Sci 2019; 10:7709-7717. [PMID: 31588319 PMCID: PMC6764278 DOI: 10.1039/c9sc02765c] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Accepted: 06/28/2019] [Indexed: 01/02/2023] Open
Abstract
The detection of alcohols by magnetic resonance techniques is important for their characterization and the monitoring of chemical change. Hyperpolarization processes can make previously inpractical measurements, such as the determination of low concentration intermediates, possible. Here, we investigate the SABRE-Relay method in order to define its key characteristics and improve the resulting 1H NMR signal gains which subsequently approach 103 per proton. We identify optimal amine proton transfer agents for SABRE-Relay and show how catalyst structure influences the outcome. The breadth of the method is revealed by expansion to more complex alcohols and the polarization of heteronuclei.
Collapse
Affiliation(s)
- Peter J Rayner
- Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , Heslington , YO10 5DD , UK .
| | - Ben J Tickner
- Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , Heslington , YO10 5DD , UK .
| | - Wissam Iali
- Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , Heslington , YO10 5DD , UK .
| | - Marianna Fekete
- Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , Heslington , YO10 5DD , UK .
| | - Alastair D Robinson
- Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , Heslington , YO10 5DD , UK .
| | - Simon B Duckett
- Centre for Hyperpolarisation in Magnetic Resonance , Department of Chemistry , University of York , Heslington , YO10 5DD , UK .
| |
Collapse
|
20
|
Ariyasingha NM, Salnikov OG, Kovtunov KV, Kovtunova LM, Bukhtiyarov VI, Goodson BM, Rosen MS, Koptyug IV, Gelovani JG, Chekmenev EY. Relaxation Dynamics of Nuclear Long-Lived Spin States in Propane and Propane-d 6 Hyperpolarized by Parahydrogen. THE JOURNAL OF PHYSICAL CHEMISTRY. C, NANOMATERIALS AND INTERFACES 2019; 123:11734-11744. [PMID: 31798763 PMCID: PMC6890414 DOI: 10.1021/acs.jpcc.9b01538] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
We report a systematic study of relaxation dynamics of hyperpolarized (HP) propane and HP propane-d6 prepared by heterogeneous pairwise parahydrogen addition to propylene and propylene-d6 respectively. Long-lived spin states (LLS) created for these molecules at the low magnetic field of 0.0475 T were employed for this study. The parahydrogen-induced overpopulation of a HP propane LLS decays exponentially with time constant (TLLS) approximately 3-fold greater than the corresponding T1 values. Both TLLS and T1 increase linearly with propane pressure in the range from 1 atm (the most biomedically relevant conditions for pulmonary MRI) to 5 atm. The TLLS value of HP propane gas at 1 atm is ~3 s. Deuteration of the substrate (propylene-d6) yields hyperpolarized propane-d6 gas with TLLS values approximately 20% shorter than those of hyperpolarized fully protonated propane gas, indicating that deuteration does not benefit the lifetime of the LLS HP state. The use of pH2 or Xe/N2 buffering gas during heterogeneous hydrogenation reaction (leading to production of 100% HP propane (no buffering gas) versus 43% HP propane gas (with 57% buffering gas) composition mixtures) results in (i) no significant changes in T1, (ii) decrease of TLLS values (by 35±7% and 8±7% respectively); and (iii) an increase of the polarization levels of HP propane gas with a propane concentration decrease (by 1.6±0.1-fold and 1.4±0.1-fold respectively despite the decrease in TLLS, which leads to disproportionately greater polarization losses during HP gas transport). Moreover, we demonstrate the feasibility of HP propane cryo-collection (which can be potentially useful for preparing larger amounts of concentrated HP propane, when buffering gas is employed), and TLLS of liquefied HP propane reaches 14.7 seconds, which is greater than the TLLS value of HP propane gas at any pressure studied. Finally, we have explored the utility of using a partial Spin-Lock Induced Crossing (SLIC) radio frequency (RF) pulse sequence for converting the overpopulated LLS into observable 1H nuclear magnetization at low magnetic field. We find that (i) the bulk of the overpopulated LLS is retained even when the optimal or near-optimal values of SLIC pulse duration are employed, and (ii) the overpopulated LLS of propane is also relatively immune to strong RF pulses-thereby, indicating that LLS is highly suitable as a spin-polarization reservoir in the context of NMR/MRI detection applications. The presented findings may be useful for improving the levels of polarization of HP propane produced by HET-PHIP via the use of an inert buffer gas; increasing the lifetime of the HP state during preparation and storage; and developing efficient approaches for ultrafast MR imaging of HP propane in the context of biomedical applications of HP propane gas, including its potential use as an inhalable contrast agent.
Collapse
Affiliation(s)
- Nuwandi M. Ariyasingha
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, Michigan, 48202, United States
| | - Oleg G. Salnikov
- International Tomography Center SB RAS, 3A Institutskaya St., Novosibirsk, 630090, Russia
- Novosibirsk State University, 2 Pirogova St., Novosibirsk, 630090, Russia
| | - Kirill V. Kovtunov
- International Tomography Center SB RAS, 3A Institutskaya St., Novosibirsk, 630090, Russia
- Novosibirsk State University, 2 Pirogova St., Novosibirsk, 630090, Russia
| | - Larisa M. Kovtunova
- Novosibirsk State University, 2 Pirogova St., Novosibirsk, 630090, Russia
- Boreskov Institute of Catalysis SB RAS, 5 Acad. Lavrentiev Pr., Novosibirsk, 630090, Russia
| | - Valerii I. Bukhtiyarov
- Novosibirsk State University, 2 Pirogova St., Novosibirsk, 630090, Russia
- Boreskov Institute of Catalysis SB RAS, 5 Acad. Lavrentiev Pr., Novosibirsk, 630090, Russia
| | - Boyd M. Goodson
- Department of Chemistry and Biochemistry and Materials Technology Center, Southern Illinois University, Carbondale, Illinois 62901, United States
| | - Matthew S. Rosen
- Massachusetts General Hospital/Athinoula A. Martinos Center for Biomedical Imaging, Boston, Massachusetts 02129, United States
| | - Igor V. Koptyug
- International Tomography Center SB RAS, 3A Institutskaya St., Novosibirsk, 630090, Russia
- Novosibirsk State University, 2 Pirogova St., Novosibirsk, 630090, Russia
| | - Juri G. Gelovani
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, Michigan, 48202, United States
| | - Eduard Y. Chekmenev
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, Michigan, 48202, United States
- Russian Academy of Sciences, Leninskiy Prospekt 14, Moscow, 119991, Russia
| |
Collapse
|
21
|
Salnikov OG, Nikolaou P, Ariyasingha NM, Kovtunov KV, Koptyug IV, Chekmenev EY. Clinical-Scale Batch-Mode Production of Hyperpolarized Propane Gas for MRI. Anal Chem 2019; 91:4741-4746. [PMID: 30855132 DOI: 10.1021/acs.analchem.9b00259] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
NMR spectroscopy and imaging (MRI) are two of the most important methods to study structure, function, and dynamics from atom to organism scale. NMR approaches often suffer from an insufficient sensitivity, which, however, can be transiently boosted using hyperpolarization techniques. One of these techniques is parahydrogen-induced polarization, which has been used to produce catalyst-free hyperpolarized propane gas with proton polarization that is 3 orders of magnitude greater than equilibrium thermal polarization at a 1.5 T field of a clinical MRI scanner. Here we show that more than 0.3 L of hyperpolarized propane gas can be produced in 2 s. This production rate is more than an order of magnitude greater than that demonstrated previously, and the reported production rate is comparable to that employed for in-human MRI using HP noble gas (e.g., 129Xe) produced via a spin exchange optical pumping (SEOP) hyperpolarization technique. We show that high polarization values can be retained despite the significant increase in the production rate of hyperpolarized propane. The enhanced signals of produced hyperpolarized propane gas were revealed by stopped-flow MRI visualization at 4.7 T. Achieving this high production rate enables the future use of this compound (already approved for unlimited use in foods by the corresponding regulating agencies, e.g., FDA in the USA, and more broadly as an E944 food additive) as a new inhalable contrast agent for diagnostic detection via MRI.
Collapse
Affiliation(s)
- Oleg G Salnikov
- International Tomography Center, SB RAS , 3A Institutskaya St. , Novosibirsk 630090 , Russia.,Novosibirsk State University , 2 Pirogova St. , Novosibirsk 630090 , Russia
| | - Panayiotis Nikolaou
- Department of Radiology , Vanderbilt University Institute of Imaging Science (VUIIS) , Nashville , Tennessee 37232-2310 , United States
| | - Nuwandi M Ariyasingha
- Department of Chemistry, Integrative Biosciences (Ibio) , Wayne State University, Karmanos Cancer Institute (KCI) , Detroit , Michigan 48202 , United States
| | - Kirill V Kovtunov
- International Tomography Center, SB RAS , 3A Institutskaya St. , Novosibirsk 630090 , Russia.,Novosibirsk State University , 2 Pirogova St. , Novosibirsk 630090 , Russia
| | - Igor V Koptyug
- International Tomography Center, SB RAS , 3A Institutskaya St. , Novosibirsk 630090 , Russia.,Novosibirsk State University , 2 Pirogova St. , Novosibirsk 630090 , Russia
| | - Eduard Y Chekmenev
- Department of Chemistry, Integrative Biosciences (Ibio) , Wayne State University, Karmanos Cancer Institute (KCI) , Detroit , Michigan 48202 , United States.,Russian Academy of Sciences , Leninskiy Prospekt 14 , Moscow 119991 , Russia
| |
Collapse
|
22
|
Skinner JG, Menichetti L, Flori A, Dost A, Schmidt AB, Plaumann M, Gallagher FA, Hövener JB. Metabolic and Molecular Imaging with Hyperpolarised Tracers. Mol Imaging Biol 2018; 20:902-918. [PMID: 30120644 DOI: 10.1007/s11307-018-1265-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Since reaching the clinic, magnetic resonance imaging (MRI) has become an irreplaceable radiological tool because of the macroscopic information it provides across almost all organs and soft tissues within the human body, all without the need for ionising radiation. The sensitivity of MR, however, is too low to take full advantage of the rich chemical information contained in the MR signal. Hyperpolarisation techniques have recently emerged as methods to overcome the sensitivity limitations by enhancing the MR signal by many orders of magnitude compared to the thermal equilibrium, enabling a new class of metabolic and molecular X-nuclei based MR tracers capable of reporting on metabolic processes at the cellular level. These hyperpolarised (HP) tracers have the potential to elucidate the complex metabolic processes of many organs and pathologies, with studies so far focusing on the fields of oncology and cardiology. This review presents an overview of hyperpolarisation techniques that appear most promising for clinical use today, such as dissolution dynamic nuclear polarisation (d-DNP), parahydrogen-induced hyperpolarisation (PHIP), Brute force hyperpolarisation and spin-exchange optical pumping (SEOP), before discussing methods for tracer detection, emerging metabolic tracers and applications and progress in preclinical and clinical application.
Collapse
Affiliation(s)
- Jason Graham Skinner
- Department of Radiology, Medical Physics, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| | - Luca Menichetti
- Institute of Clinical Physiology, National Research Council (CNR), Pisa, Italy
- Fondazione CNR/Regione Toscana G. Monasterio, Pisa, Italy
| | - Alessandra Flori
- Fondazione CNR/Regione Toscana G. Monasterio, Pisa, Italy
- Institute of Life Sciences, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Anna Dost
- Department of Radiology, Medical Physics, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Andreas Benjamin Schmidt
- Department of Radiology, Medical Physics, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
- Section Biomedical Imaging and MOIN CC, University Medical Center Schleswig Holstein, Kiel University, Kiel, Germany
| | - Markus Plaumann
- Institute of Biometrics and Medical Informatics, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | | | - Jan-Bernd Hövener
- Section Biomedical Imaging and MOIN CC, University Medical Center Schleswig Holstein, Kiel University, Kiel, Germany.
| |
Collapse
|
23
|
Manoharan A, Rayner PJ, Fekete M, Iali W, Norcott P, Hugh Perry V, Duckett SB. Catalyst-Substrate Effects on Biocompatible SABRE Hyperpolarization. Chemphyschem 2018; 20:285-294. [DOI: 10.1002/cphc.201800915] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Revised: 11/02/2018] [Indexed: 11/08/2022]
Affiliation(s)
- Anand Manoharan
- University of York; Department of Chemistry Heslington; York YO10 5DD UK
| | - Peter J. Rayner
- University of York; Department of Chemistry Heslington; York YO10 5DD UK
| | - Marianna Fekete
- University of York; Department of Chemistry Heslington; York YO10 5DD UK
| | - Wissam Iali
- University of York; Department of Chemistry Heslington; York YO10 5DD UK
| | - Philip Norcott
- University of York; Department of Chemistry Heslington; York YO10 5DD UK
| | - V. Hugh Perry
- School of Biological Sciences; University of Southampton; Southampton UK
| | - Simon B. Duckett
- University of York; Department of Chemistry Heslington; York YO10 5DD UK
| |
Collapse
|
24
|
Salnikov OG, Kovtunov KV, Nikolaou P, Kovtunova LM, Bukhtiyarov VI, Koptyug IV, Chekmenev EY. Heterogeneous Parahydrogen Pairwise Addition to Cyclopropane. Chemphyschem 2018; 19:2621-2626. [PMID: 30039565 PMCID: PMC6197887 DOI: 10.1002/cphc.201800690] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Indexed: 11/05/2022]
Abstract
Hyperpolarized gases revolutionize functional pulmonary imaging. Hyperpolarized propane is a promising emerging contrast agent for pulmonary MRI. Unlike hyperpolarized noble gases, proton-hyperpolarized propane gas can be imaged using conventional MRI scanners with proton imaging capability. Moreover, it is non-toxic odorless anesthetic. Furthermore, propane hyperpolarization can be accomplished by pairwise addition of parahydrogen to propylene. Here, we demonstrate the feasibility of propane hyperpolarization via hydrogenation of cyclopropane with parahydrogen. 1 H propane polarization up to 2.4 % is demonstrated here using 82 % parahydrogen enrichment and heterogeneous Rh/TiO2 hydrogenation catalyst. This level of polarization is several times greater than that obtained with propylene as a precursor under the same conditions despite the fact that direct pairwise addition of parahydrogen to cyclopropane may also lead to formation of propane with NMR-invisible hyperpolarization due to magnetic equivalence of nascent parahydrogen protons in two CH3 groups. NMR-visible hyperpolarized propane demonstrated here can be formed only via a reaction pathway involving cleavage of at least one C-H bond in the reactant molecule. The resulting NMR signal enhancement of hyperpolarized propane was sufficient for 2D gradient echo MRI of ∼5.5 mL phantom with 1×1 mm2 spatial resolution and 64×64 imaging matrix despite relatively low chemical conversion of cyclopropane substrate.
Collapse
Affiliation(s)
- Oleg G. Salnikov
- International Tomography Center, SB RAS, 3A Institutskaya st., Novosibirsk 630090, Russia,
- Novosibirsk State University, 2 Pirogova st., Novosibirsk 630090, Russia
| | - Kirill V. Kovtunov
- International Tomography Center, SB RAS, 3A Institutskaya st., Novosibirsk 630090, Russia,
- Novosibirsk State University, 2 Pirogova st., Novosibirsk 630090, Russia
| | - Panayiotis Nikolaou
- Vanderbilt University Institute of Imaging Science (VUIIS), Department of Radiology, Department of Biomedical Engineering, and Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Medical Center, Nashville, TN 37232-2310, United States
| | - Larisa M. Kovtunova
- Novosibirsk State University, 2 Pirogova st., Novosibirsk 630090, Russia
- Boreskov Institute of Catalysis, SB RAS, 5 Acad. Lavrentiev pr., Novosibirsk 630090, Russia
| | - Valerii I. Bukhtiyarov
- Novosibirsk State University, 2 Pirogova st., Novosibirsk 630090, Russia
- Boreskov Institute of Catalysis, SB RAS, 5 Acad. Lavrentiev pr., Novosibirsk 630090, Russia
| | - Igor V. Koptyug
- International Tomography Center, SB RAS, 3A Institutskaya st., Novosibirsk 630090, Russia,
- Novosibirsk State University, 2 Pirogova st., Novosibirsk 630090, Russia
| | - Eduard Y. Chekmenev
- Vanderbilt University Institute of Imaging Science (VUIIS), Department of Radiology, Department of Biomedical Engineering, and Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Medical Center, Nashville, TN 37232-2310, United States
- Russian Academy of Sciences, 14 Leninskiy prospect, Moscow 119991, Russia
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, MI 48202, United States,
| |
Collapse
|
25
|
Woods JC, Conradi MS. 3He diffusion MRI in human lungs. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 292:90-98. [PMID: 29705031 PMCID: PMC6386180 DOI: 10.1016/j.jmr.2018.04.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2017] [Revised: 03/05/2018] [Accepted: 04/11/2018] [Indexed: 06/08/2023]
Abstract
Hyperpolarized 3He gas allows the air spaces of the lungs to be imaged via MRI. Imaging of restricted diffusion is addressed here, which allows the microstructure of the lung to be characterized through the physical restrictions to gas diffusion presented by airway and alveolar walls in the lung. Measurements of the apparent diffusion coefficient (ADC) of 3He at time scales of milliseconds and seconds are compared; measurement of acinar airway sizes by determination of the microscopic anisotropy of diffusion is discussed. This is where Dr. JJH Ackerman's influence was greatest in aiding the formation of the Washington University 3He group, involving early a combination of physicists, radiologists, and surgeons, as the first applications of 3He ADC were to COPD and its destruction/modification of lung microstructure via emphysema. The sensitivity of the method to early COPD is demonstrated, as is its validation by direct comparison to histology. More recently the method has been used broadly in adult and pediatric obstructive lung diseases, from severe asthma to cystic fibrosis to bronchopulmonary dysplasia, a result of premature birth. These applications of the technique are discussed briefly.
Collapse
Affiliation(s)
- Jason C Woods
- Center for Pulmonary Imaging Research, Departments of Radiology and Pediatrics (Pulmonary Medicine), Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, ML 5033, Cincinnati, OH 45229, USA; Department of Physics, Washington University, One Brookings Drive, CB 1105, St Louis, MO 63130, USA.
| | - Mark S Conradi
- ABQMR, Inc., 2301 Yale Blvd. SE, Suite C2, Albuquerque, NM 87106, USA; Department of Physics, Washington University, One Brookings Drive, CB 1105, St Louis, MO 63130, USA.
| |
Collapse
|
26
|
Rayner PJ, Duckett SB. Signal Amplification by Reversible Exchange (SABRE): From Discovery to Diagnosis. Angew Chem Int Ed Engl 2018; 57:6742-6753. [DOI: 10.1002/anie.201710406] [Citation(s) in RCA: 76] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Revised: 12/12/2017] [Indexed: 11/10/2022]
Affiliation(s)
- Peter J. Rayner
- Centre of Hyperpolarisation in Magnetic Resonance, Department of Chemistry; University of York; Heslington YO10 5DD UK
| | - Simon B. Duckett
- Centre of Hyperpolarisation in Magnetic Resonance, Department of Chemistry; University of York; Heslington YO10 5DD UK
| |
Collapse
|
27
|
Rayner PJ, Duckett SB. Signalverstärkung durch reversiblen Austausch (SABRE): von der Entdeckung zur diagnostischen Anwendung. Angew Chem Int Ed Engl 2018. [DOI: 10.1002/ange.201710406] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Affiliation(s)
- Peter J. Rayner
- Centre of Hyperpolarisation in Magnetic Resonance, Department of Chemistry; University of York; Heslington YO10 5DD Großbritannien
| | - Simon B. Duckett
- Centre of Hyperpolarisation in Magnetic Resonance, Department of Chemistry; University of York; Heslington YO10 5DD Großbritannien
| |
Collapse
|
28
|
Manoharan A, Rayner PJ, Iali W, Burns MJ, Perry VH, Duckett SB. Achieving Biocompatible SABRE: An in vitro Cytotoxicity Study. ChemMedChem 2018; 13:352-359. [PMID: 29232489 PMCID: PMC5838797 DOI: 10.1002/cmdc.201700725] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Indexed: 01/09/2023]
Abstract
Production of a biocompatible hyperpolarized bolus for signal amplification by reversible exchange (SABRE) could open the door to simple clinical diagnosis via magnetic resonance imaging. Essential to successful progression to preclinical/clinical applications is the determination of the toxicology profile of the SABRE reaction mixture. Herein, we exemplify the cytotoxicity of the SABRE approach using in vitro cell assays. We conclude that the main cause of the observed toxicity is due to the SABRE catalyst. We therefore illustrate two catalyst removal methods: one involving deactivation and ion-exchange chromatography, and the second using biphasic catalysis. These routes produce a bolus suitable for future in vivo study.
Collapse
Affiliation(s)
- Anand Manoharan
- Department of ChemistryUniversity of YorkHeslingtonYorkYO10 5DDUK
| | - Peter J. Rayner
- Department of ChemistryUniversity of YorkHeslingtonYorkYO10 5DDUK
| | - Wissam Iali
- Department of ChemistryUniversity of YorkHeslingtonYorkYO10 5DDUK
| | - Michael J. Burns
- Department of ChemistryUniversity of YorkHeslingtonYorkYO10 5DDUK
| | - V. Hugh Perry
- School of Biological SciencesUniversity of SouthamptonSouthamptonUK
| | - Simon B. Duckett
- Department of ChemistryUniversity of YorkHeslingtonYorkYO10 5DDUK
| |
Collapse
|
29
|
Coffey AM, Shchepin RV, Feng B, Colon RD, Wilkens K, Waddell KW, Chekmenev EY. A pulse programmable parahydrogen polarizer using a tunable electromagnet and dual channel NMR spectrometer. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2017; 284:115-124. [PMID: 29028543 PMCID: PMC5708540 DOI: 10.1016/j.jmr.2017.09.013] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Revised: 09/20/2017] [Accepted: 09/28/2017] [Indexed: 05/12/2023]
Abstract
Applications of parahydrogen induced polarization (PHIP) often warrant conversion of the chemically-synthesized singlet-state spin order into net heteronuclear magnetization. In order to obtain optimal yields from the overall hyperpolarization process, catalytic hydrogenation must be tightly synchronized to subsequent radiofrequency (RF) transformations of spin order. Commercial NMR consoles are designed to synchronize applied waves on multiple channels and consequently are well-suited as controllers for these types of hyperpolarization experiments that require tight coordination of RF and non-RF events. Described here is a PHIP instrument interfaced to a portable NMR console operating with a static field electromagnet in the milliTesla regime. In addition to providing comprehensive control over chemistry and RF events, this setup condenses the PHIP protocol into a pulse-program that in turn can be readily shared in the manner of traditional pulse sequences. In this device, a TTL multiplexer was constructed to convert spectrometer TTL outputs into 24 VDC signals. These signals then activated solenoid valves to control chemical shuttling and reactivity in PHIP experiments. Consolidating these steps in a pulse-programming environment speeded calibration and improved quality assurance by enabling the B0/B1 fields to be tuned based on the direct acquisition of thermally polarized and hyperpolarized NMR signals. Performance was tested on the parahydrogen addition product of 2-hydroxyethyl propionate-1-13C-d3, where the 13C polarization was estimated to be P13C=20±2.5% corresponding to 13C signal enhancement approximately 25 million-fold at 9.1 mT or approximately 77,000-fold 13C enhancement at 3 T with respect to thermally induced polarization at room temperature.
Collapse
Affiliation(s)
- Aaron M Coffey
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232-2310, United States
| | - Roman V Shchepin
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232-2310, United States
| | - Bibo Feng
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232-2310, United States
| | - Raul D Colon
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232-2310, United States
| | - Ken Wilkens
- Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232-2310, United States
| | - Kevin W Waddell
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232-2310, United States
| | - Eduard Y Chekmenev
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232-2310, United States; Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University, Nashville, TN 37232-2310, United States; Russian Academy of Sciences, Leninskiy Prospekt 14, Moscow 119991, Russia.
| |
Collapse
|
30
|
Imai H, Yoshimura H, Kimura A, Fujiwara H. Continuous flow production of concentrated hyperpolarized xenon gas from a dilute xenon gas mixture by buffer gas condensation. Sci Rep 2017; 7:7352. [PMID: 28779105 PMCID: PMC5544720 DOI: 10.1038/s41598-017-07695-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Accepted: 07/03/2017] [Indexed: 11/22/2022] Open
Abstract
We present a new method for the continuous flow production of concentrated hyperpolarized xenon-129 (HP 129Xe) gas from a dilute xenon (Xe) gas mixture with high nuclear spin polarization. A low vapor pressure (i.e., high boiling-point) gas was introduced as an alternative to molecular nitrogen (N2), which is the conventional quenching gas for generating HP 129Xe via Rb-Xe spin-exchange optical-pumping (SEOP). In contrast to the generally used method of extraction by freezing Xe after the SEOP process, the quenching gas separated as a liquid at moderately low temperature so that Xe was maintained in its gaseous state, allowing the continuous delivery of highly polarized concentrated Xe gas. We selected isobutene as the candidate quenching gas and our method was demonstrated experimentally while comparing its performance with N2. Isobutene could be liquefied and removed from the Xe gas mixture using a cold trap, and the concentrated HP 129Xe gas exhibited a significantly enhanced nuclear magnetic resonance (NMR) signal. Although the system requires further optimization depending on the intended purpose, our approach presented here could provide a simple means for performing NMR or magnetic resonance imaging (MRI) measurements continuously using HP 129Xe with improved sensitivity.
Collapse
Affiliation(s)
- Hirohiko Imai
- Graduate School of Medicine, Osaka University, Osaka, 565-0871, Japan. .,Graduate School of Informatics, Kyoto University, Kyoto, 606-8501, Japan.
| | | | - Atsuomi Kimura
- Graduate School of Medicine, Osaka University, Osaka, 565-0871, Japan
| | - Hideaki Fujiwara
- Graduate School of Medicine, Osaka University, Osaka, 565-0871, Japan
| |
Collapse
|
31
|
Coffey AM, Feldman MA, Shchepin RV, Barskiy DA, Truong ML, Pham W, Chekmenev EY. High-resolution hyperpolarized in vivo metabolic 13C spectroscopy at low magnetic field (48.7mT) following murine tail-vein injection. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2017; 281:246-252. [PMID: 28651245 PMCID: PMC5544012 DOI: 10.1016/j.jmr.2017.06.009] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Revised: 06/12/2017] [Accepted: 06/14/2017] [Indexed: 05/20/2023]
Abstract
High-resolution 13C NMR spectroscopy of hyperpolarized succinate-1-13C-2,3-d2 is reported in vitro and in vivo using a clinical-scale, biplanar (80cm-gap) 48.7mT permanent magnet with a high homogeneity magnetic field. Non-localized 13C NMR spectra were recorded at 0.52MHz resonance frequency over the torso of a tumor-bearing mouse every 2s. Hyperpolarized 13C NMR signals with linewidths of ∼3Hz (corresponding to ∼6ppm) were recorded in vitro (2mL in a syringe) and in vivo (over a mouse torso). Comparison of the full width at half maximum (FWHM) for 13C NMR spectra acquired at 48.7mT and at 4.7T in a small-animal MRI scanner demonstrates a factor of ∼12 improvement for the 13C resonance linewidth attainable at 48.7mT compared to that at 4.7T in vitro. 13C hyperpolarized succinate-1-13C resonance linewidths in vivo are at least one order of magnitude narrower at 48.7mT compared to those observed in high-field (≥3T) studies employing HP contrast agents. The demonstrated high-resolution 13C in vivo spectroscopy could be useful for high-sensitivity spectroscopic studies involving monitoring HP agent uptake or detecting metabolism using HP contrast agents with sufficiently large 13C chemical shift differences.
Collapse
Affiliation(s)
- Aaron M Coffey
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology, Vanderbilt University, Nashville, TN 37232-2310, United States.
| | - Matthew A Feldman
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology, Vanderbilt University, Nashville, TN 37232-2310, United States
| | - Roman V Shchepin
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology, Vanderbilt University, Nashville, TN 37232-2310, United States
| | - Danila A Barskiy
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology, Vanderbilt University, Nashville, TN 37232-2310, United States
| | - Milton L Truong
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology, Vanderbilt University, Nashville, TN 37232-2310, United States
| | - Wellington Pham
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology, Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232-2310, United States; Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University, Nashville, TN 37232-2310, United States
| | - Eduard Y Chekmenev
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology, Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232-2310, United States; Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University, Nashville, TN 37232-2310, United States; Russian Academy of Sciences, Leninskiy Prospekt 14, Moscow 119991, Russia.
| |
Collapse
|
32
|
McMahon MT, Gilad AA. Cellular and Molecular Imaging Using Chemical Exchange Saturation Transfer. Top Magn Reson Imaging 2017; 25:197-204. [PMID: 27748713 DOI: 10.1097/rmr.0000000000000105] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Chemical exchange saturation transfer (CEST) is a powerful new tool well suited for molecular imaging. This technology enables the detection of low concentration probes through selective labeling of rapidly exchanging protons or other spins on the probes. In this review, we will highlight the unique features of CEST imaging technology and describe the different types of CEST agents that are suited for molecular imaging studies, including CEST theranostic agents, CEST reporter genes, and CEST environmental sensors.
Collapse
Affiliation(s)
- Michael T McMahon
- *F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute †The Russell H. Morgan Department of Radiology and Radiological Sciences, Division of MR Research ‡Cellular Imaging Section and Vascular Biology Program, Institute for Cell Engineering, Johns Hopkins University School of Medicine, Baltimore, MD
| | | |
Collapse
|
33
|
Delivering strong 1H nuclear hyperpolarization levels and long magnetic lifetimes through signal amplification by reversible exchange. Proc Natl Acad Sci U S A 2017; 114:E3188-E3194. [PMID: 28377523 DOI: 10.1073/pnas.1620457114] [Citation(s) in RCA: 107] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Hyperpolarization turns typically weak NMR and MRI responses into strong signals so that ordinarily impractical measurements become possible. The potential to revolutionize analytical NMR and clinical diagnosis through this approach reflect this area's most compelling outcomes. Methods to optimize the low-cost parahydrogen-based approach signal amplification by reversible exchange with studies on a series of biologically relevant nicotinamides and methyl nicotinates are detailed. These procedures involve specific 2H labeling in both the agent and catalyst and achieve polarization lifetimes of ca 2 min with 50% polarization in the case of methyl-4,6-d2 -nicotinate. Because a 1.5-T hospital scanner has an effective 1H polarization level of just 0.0005% this strategy should result in compressed detection times for chemically discerning measurements that probe disease. To demonstrate this technique's generality, we exemplify further studies on a range of pyridazine, pyrimidine, pyrazine, and isonicotinamide analogs that feature as building blocks in biochemistry and many disease-treating drugs.
Collapse
|
34
|
Barskiy DA, Coffey AM, Nikolaou P, Mikhaylov DM, Goodson BM, Branca RT, Lu GJ, Shapiro MG, Telkki VV, Zhivonitko VV, Koptyug IV, Salnikov OG, Kovtunov KV, Bukhtiyarov VI, Rosen MS, Barlow MJ, Safavi S, Hall IP, Schröder L, Chekmenev EY. NMR Hyperpolarization Techniques of Gases. Chemistry 2017; 23:725-751. [PMID: 27711999 PMCID: PMC5462469 DOI: 10.1002/chem.201603884] [Citation(s) in RCA: 110] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2016] [Indexed: 01/09/2023]
Abstract
Nuclear spin polarization can be significantly increased through the process of hyperpolarization, leading to an increase in the sensitivity of nuclear magnetic resonance (NMR) experiments by 4-8 orders of magnitude. Hyperpolarized gases, unlike liquids and solids, can often be readily separated and purified from the compounds used to mediate the hyperpolarization processes. These pure hyperpolarized gases enabled many novel MRI applications including the visualization of void spaces, imaging of lung function, and remote detection. Additionally, hyperpolarized gases can be dissolved in liquids and can be used as sensitive molecular probes and reporters. This Minireview covers the fundamentals of the preparation of hyperpolarized gases and focuses on selected applications of interest to biomedicine and materials science.
Collapse
Affiliation(s)
- Danila A Barskiy
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
| | - Aaron M Coffey
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
| | - Panayiotis Nikolaou
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
| | | | - Boyd M Goodson
- Southern Illinois University, Department of Chemistry and Biochemistry, Materials Technology Center, Carbondale, IL, 62901, USA
| | - Rosa T Branca
- Department of Physics and Astronomy, Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA
| | - George J Lu
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
| | - Mikhail G Shapiro
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
| | | | - Vladimir V Zhivonitko
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Igor V Koptyug
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Oleg G Salnikov
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Kirill V Kovtunov
- International Tomography Center SB RAS, 630090, Novosibirsk, Russia
- Novosibirsk State University, Pirogova St. 2, 630090, Novosibirsk, Russia
| | - Valerii I Bukhtiyarov
- Boreskov Institute of Catalysis SB RAS, 5 Acad. Lavrentiev Pr., 630090, Novosibirsk, Russia
| | - Matthew S Rosen
- MGH/A.A. Martinos Center for Biomedical Imaging, Boston, MA, 02129, USA
| | - Michael J Barlow
- Respiratory Medicine Department, Queen's Medical Centre, University of Nottingham Medical School, Nottingham, NG7 2UH, UK
| | - Shahideh Safavi
- Respiratory Medicine Department, Queen's Medical Centre, University of Nottingham Medical School, Nottingham, NG7 2UH, UK
| | - Ian P Hall
- Respiratory Medicine Department, Queen's Medical Centre, University of Nottingham Medical School, Nottingham, NG7 2UH, UK
| | - Leif Schröder
- Molecular Imaging, Department of Structural Biology, Leibniz-Institut für Molekulare Pharmakologie (FMP), 13125, Berlin, Germany
| | - Eduard Y Chekmenev
- Department of Radiology, Department of Biomedical Engineering, Department of Physics, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University, Nashville, TN, 37232, USA
- Russian Academy of Sciences, 119991, Moscow, Russia
| |
Collapse
|
35
|
Walkup LL, Thomen RP, Akinyi T, Watters E, Ruppert K, Clancy JP, Woods JC, Cleveland ZI. Feasibility, tolerability and safety of pediatric hyperpolarized 129Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis. Pediatr Radiol 2016; 46:1651-1662. [PMID: 27492388 PMCID: PMC5083137 DOI: 10.1007/s00247-016-3672-1] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Revised: 06/05/2016] [Accepted: 07/20/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND Hyperpolarized 129Xe is a promising contrast agent for MRI of pediatric lung function, but its safety and tolerability in children have not been rigorously assessed. OBJECTIVE To assess the feasibility, safety and tolerability of hyperpolarized 129Xe gas as an inhaled contrast agent for pediatric pulmonary MRI in healthy control subjects and in children with cystic fibrosis. MATERIALS AND METHODS Seventeen healthy control subjects (ages 6-15 years, 11 boys) and 11 children with cystic fibrosis (ages 8-16 years, 4 boys) underwent 129Xe MRI, receiving up to three doses of 129Xe gas prepared by either a commercially available or a homebuilt 129Xe polarizer. Subject heart rate and SpO2 were monitored for 2 min post inhalation and compared to resting baseline values. Adverse events were reported via follow-up phone call at days 1 and 30 (range ±7 days) post-MRI. RESULTS All children tolerated multiple doses of 129Xe, and no children withdrew from the study. Relative to baseline, most children who received a full dose of gas for imaging (10 of 12 controls and 8 of 11 children with cystic fibrosis) experienced a nadir in SpO2 (mean -6.0 ± standard deviation 7.2%, P≤0.001); however within 2 min post inhalation SpO2 values showed no significant difference from baseline (P=0.11). There was a slight elevation in heart rate (mean +6.6 ± 13.9 beats per minute [bpm], P=0.021), which returned from baseline within 2 min post inhalation (P=0.35). Brief side effects related to the anesthetic properties of xenon were mild and quickly resolved without intervention. No serious or severe adverse events were observed; in total, four minor adverse events (14.3%) were reported following 129Xe MRI, but all were deemed unrelated to the study. CONCLUSION The feasibility, safety and tolerability of 129Xe MRI has been assessed in a small group of children as young as 6 years. SpO2 changes were consistent with the expected physiological effects of a short anoxic breath-hold, and other mild side effects were consistent with the known anesthetic properties of xenon and with previous safety assessments of 129Xe MRI in adults. Hyperpolarized 129Xe is a safe and well-tolerated inhaled contrast agent for pulmonary MR imaging in healthy children and in children with cystic fibrosis who have mild to moderate lung disease.
Collapse
Affiliation(s)
- Laura L. Walkup
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA
| | - Robert P. Thomen
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA,Department of Physics, Washington University in St. Louis, St. Louis, MO, USA
| | - Teckla Akinyi
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA,Biomedical Engineering Program, University of Cincinnati, Cincinnati, OH, USA
| | - Erin Watters
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA
| | - Kai Ruppert
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA
| | - John P. Clancy
- Division of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
| | - Jason C. Woods
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA,Department of Physics, Washington University in St. Louis, St. Louis, MO, USA
| | - Zackary I. Cleveland
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Ave., MLC 5033, Cincinnati, OH 45229, USA,Biomedical Engineering Program, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
36
|
Hodono S, Imai H, Yamauchi Y, Kawamura A, Matsumoto H, Okumura S, Fujiwara H, Kimura A. Hyperpolarized (129) Xe MRI using isobutene as a new quenching gas. NMR IN BIOMEDICINE 2016; 29:1414-1419. [PMID: 27526627 DOI: 10.1002/nbm.3585] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2015] [Revised: 06/20/2016] [Accepted: 06/22/2016] [Indexed: 06/06/2023]
Abstract
The use of a quenching gas, isobutene, with a low vapor pressure was investigated to enhance the utility of hyperpolarized (129) Xe (HP Xe) MRI. Xenon mixed with isobutene was hyperpolarized using a home-built apparatus for continuously producing HP Xe. The isobutene was then readily liquefied and separated almost totally by continuous condensation at about 173 K, because the vapor pressure of isobutene (0.247 kPa) is much lower than that of Xe (157 kPa). Finally, the neat Xe gas was continuously delivered to mice by spontaneous inhalation. The HP Xe MRI was enhanced twofold in polarization level and threefold in signal intensity when isobutene was adopted as the quenching gas instead of N2 . The usefulness of the HP Xe MRI was verified by application to pulmonary functional imaging of spontaneously breathing mice, where the parameters of fractional ventilation (ra ) and gas exchange (fD ) were evaluated, aiming at future extension to preclinical studies. This is the first application of isobutene as a quenching gas for HP Xe MRI.
Collapse
Affiliation(s)
- Shota Hodono
- Department of Medical Physics and Engineering, Division of Health Sciences, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Hirohiko Imai
- Department of Medical Physics and Engineering, Division of Health Sciences, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Yukiko Yamauchi
- Department of Medical Physics and Engineering, Division of Health Sciences, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Ayano Kawamura
- Department of Medical Physics and Engineering, Division of Health Sciences, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Hironobu Matsumoto
- Department of Medical Physics and Engineering, Division of Health Sciences, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Shintaro Okumura
- Department of Medical Physics and Engineering, Division of Health Sciences, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Hideaki Fujiwara
- Department of Medical Physics and Engineering, Division of Health Sciences, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Atsuomi Kimura
- Department of Medical Physics and Engineering, Division of Health Sciences, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.
| |
Collapse
|
37
|
Coffey AM, Shchepin RV, Truong ML, Wilkens K, Pham W, Chekmenev EY. Open-Source Automated Parahydrogen Hyperpolarizer for Molecular Imaging Using (13)C Metabolic Contrast Agents. Anal Chem 2016; 88:8279-88. [PMID: 27478927 PMCID: PMC4991553 DOI: 10.1021/acs.analchem.6b02130] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
![]()
An
open-source hyperpolarizer producing 13C hyperpolarized
contrast agents using parahydrogen induced polarization (PHIP) for
biomedical and other applications is presented. This PHIP hyperpolarizer
utilizes an Arduino microcontroller in conjunction with a readily
modified graphical user interface written in the open-source processing
software environment to completely control the PHIP hyperpolarization
process including remotely triggering an NMR spectrometer for efficient
production of payloads of hyperpolarized contrast agent and in situ quality assurance of the produced hyperpolarization.
Key advantages of this hyperpolarizer include: (i) use of open-source
software and hardware seamlessly allowing for replication and further
improvement as well as readily customizable integration with other
NMR spectrometers or MRI scanners (i.e., this is a multiplatform design),
(ii) relatively low cost and robustness, and (iii) in situ detection capability and complete automation. The device performance
is demonstrated by production of a dose (∼2–3 mL) of
hyperpolarized 13C-succinate with %P13C ∼ 28% and 30 mM concentration and 13C-phospholactate
at %P13C ∼ 15% and 25 mM concentration
in aqueous medium. These contrast agents are used for ultrafast molecular
imaging and spectroscopy at 4.7 and 0.0475 T. In particular, the conversion
of hyperpolarized 13C-phospholactate to 13C-lactate in vivo is used here to demonstrate the feasibility of ultrafast
multislice 13C MRI after tail vein injection of hyperpolarized 13C-phospholactate in mice.
Collapse
Affiliation(s)
| | | | | | | | | | - Eduard Y Chekmenev
- Russian Academy of Sciences , Leninskiy Prospekt 14, Moscow, 119991, Russia
| |
Collapse
|
38
|
Fox MS, Gaudet JM, Foster PJ. Fluorine-19 MRI Contrast Agents for Cell Tracking and Lung Imaging. MAGNETIC RESONANCE INSIGHTS 2016; 8:53-67. [PMID: 27042089 PMCID: PMC4807887 DOI: 10.4137/mri.s23559] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/23/2015] [Revised: 01/24/2016] [Accepted: 01/31/2016] [Indexed: 02/06/2023]
Abstract
Fluorine-19 (19F)-based contrast agents for magnetic resonance imaging stand to revolutionize imaging-based research and clinical trials in several fields of medical intervention. First, their use in characterizing in vivo cell behavior may help bring cellular therapy closer to clinical acceptance. Second, their use in lung imaging provides novel noninvasive interrogation of the ventilated airspaces without the need for complicated, hard-to-distribute hardware. This article reviews the current state of 19F-based cell tracking and lung imaging using magnetic resonance imaging and describes the link between the methods across these fields and how they may mutually benefit from solutions to mutual problems encountered when imaging 19F-containing compounds, as well as hardware and software advancements.
Collapse
Affiliation(s)
- Matthew S Fox
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada.; Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada
| | - Jeffrey M Gaudet
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada.; Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada
| | - Paula J Foster
- Department of Medical Biophysics, University of Western Ontario, London, ON, Canada.; Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada
| |
Collapse
|
39
|
Thomen RP, Quirk JD, Roach D, Egan‐Rojas T, Ruppert K, Yusen RD, Altes TA, Yablonskiy DA, Woods JC. Direct comparison of
129
X
e diffusion measurements with quantitative histology in human lungs. Magn Reson Med 2016; 77:265-272. [DOI: 10.1002/mrm.26120] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Revised: 12/13/2015] [Accepted: 12/17/2015] [Indexed: 12/22/2022]
Affiliation(s)
- Robert P. Thomen
- Center for Pulmonary Imaging ResearchCincinnati Children's Hospital Medical CenterCincinnati OH USA
- Department of PhysicsWashington University in St. LouisSt. Louis MO USA
| | - James D. Quirk
- Mallinckrodt Institute of RadiologyWashington University School of MedicineSt. Louis MO USA
| | - David Roach
- Center for Pulmonary Imaging ResearchCincinnati Children's Hospital Medical CenterCincinnati OH USA
| | - Tiffany Egan‐Rojas
- Center for Pulmonary Imaging ResearchCincinnati Children's Hospital Medical CenterCincinnati OH USA
| | - Kai Ruppert
- Center for Pulmonary Imaging ResearchCincinnati Children's Hospital Medical CenterCincinnati OH USA
| | - Roger D. Yusen
- Division of Pulmonary and Critical Care MedicineWashington University School of MedicineSt. Louis MO USA
| | | | - Dmitriy A. Yablonskiy
- Mallinckrodt Institute of RadiologyWashington University School of MedicineSt. Louis MO USA
| | - Jason C. Woods
- Center for Pulmonary Imaging ResearchCincinnati Children's Hospital Medical CenterCincinnati OH USA
- Department of PhysicsWashington University in St. LouisSt. Louis MO USA
| |
Collapse
|
40
|
Chauvin C, Liagre L, Boutin C, Mari E, Léonce E, Carret G, Coltrinari B, Berthault P. Note: Spin-exchange optical pumping in a van. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:016105. [PMID: 26827366 DOI: 10.1063/1.4940928] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The advent of spin-hyperpolarization techniques designed to overcome the sensitivity issue of nuclear magnetic resonance owing to polarization transfer from more ordered systems has recently raised great enthusiasm. However, the out-of-equilibrium character of the polarization requires a close proximity between the area of production and the site of use. We present here a mobile spin-exchange optical pumping setup that enables production of laser-polarized noble gases in a standalone mode, in close proximity to hospitals or research laboratories. Only compressed air and mains power need to be supplied by the host laboratory.
Collapse
Affiliation(s)
- C Chauvin
- SB2SM, CEA, CNRS, Université Paris-Saclay, CEA Saclay, 91191 Gif sur Yvette, France
| | - L Liagre
- SB2SM, CEA, CNRS, Université Paris-Saclay, CEA Saclay, 91191 Gif sur Yvette, France
| | - C Boutin
- NIMBE, CEA, CNRS, Université Paris-Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| | - E Mari
- NIMBE, CEA, CNRS, Université Paris-Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| | - E Léonce
- NIMBE, CEA, CNRS, Université Paris-Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| | - G Carret
- NIMBE, CEA, CNRS, Université Paris-Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| | - B Coltrinari
- NIMBE, CEA, CNRS, Université Paris-Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| | - P Berthault
- NIMBE, CEA, CNRS, Université Paris-Saclay, CEA Saclay, 91191 Gif-sur-Yvette, France
| |
Collapse
|
41
|
Abstract
Imaging has played a vital role in the clinical assessment of bronchopulmonary dysplasia (BPD) since its first recognition. In this review, how chest radiograph, computerized tomography (CT), nuclear medicine, and MRI have contributed to the understanding of BPD pathology and how emerging advancements in these methods, including low-dose and quantitative CT, sophisticated proton and hyperpolarized-gas MRI, influence the future of BPD imaging are discussed.
Collapse
Affiliation(s)
- Laura L Walkup
- Division of Pulmonary Medicine, Department of Radiology, Center for Pulmonary Imaging Research, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, MC 5033, Cincinnati, OH 42229, USA
| | - Jason C Woods
- Division of Pulmonary Medicine, Department of Radiology, Center for Pulmonary Imaging Research, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, MC 5033, Cincinnati, OH 42229, USA.
| |
Collapse
|
42
|
Walkup LL, Woods JC. Advances in Imaging Cystic Fibrosis Lung Disease. PEDIATRIC ALLERGY IMMUNOLOGY AND PULMONOLOGY 2015; 28:220-229. [DOI: 10.1089/ped.2015.0588] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Affiliation(s)
- Laura L. Walkup
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio
| | - Jason C. Woods
- Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio
| |
Collapse
|
43
|
Ouriadov A, Fox M, Hegarty E, Parraga G, Wong E, Santyr GE. Early stage radiation-induced lung injury detected using hyperpolarized (129) Xe Morphometry: Proof-of-concept demonstration in a rat model. Magn Reson Med 2015; 75:2421-31. [PMID: 26154889 DOI: 10.1002/mrm.25825] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2015] [Revised: 05/27/2015] [Accepted: 06/08/2015] [Indexed: 11/08/2022]
Abstract
PURPOSE Radiation-induced lung injury (RILI) is still the major dose-limiting toxicity related to lung cancer radiation therapy, and it is difficult to predict and detect patients who are at early risk of severe pneumonitis and fibrosis. The goal of this proof-of-concept preclinical demonstration was to investigate the potential of hyperpolarized (129) Xe diffusion-weighted MRI to detect the lung morphological changes associated with early stage RILI. METHODS Hyperpolarized (129) Xe MRI was performed using eight different diffusion sensitizations (0.0-115 s/cm(2) ) in a small group of control rats (n = 4) and rats 2 wk after radiation exposure (n = 5). The diffusion-weighted images were used to obtain morphological estimates of the pulmonary parenchyma including external radius (R), internal radius (r), alveolar sleeve depth (h), and mean airspace chord length (Lm ). The histological mean linear intercept (MLI) were obtained for five control and five irradiated animals. RESULTS Mean R, r, and Lm were both significantly different (P < 0.02) in the irradiated rats (74 ± 17 µm, 43 ± 12 µm, and 54 ± 17 µm, respectively) compared with the control rats (100 ± 12 µm, 67 ± 10 µm, and 79 ± 12 µm, respectively). Changes in measured Lm values were consistent with changes in MLI values observed by histology. CONCLUSIONS Hyperpolarized (129) Xe MRI provides a way to detect and measure regional microanatomical changes in lung parenchyma in a preclinical model of RILI. Magn Reson Med 75:2421-2431, 2016. © 2015 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Alexei Ouriadov
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada
| | - Matthew Fox
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada.,Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Elaine Hegarty
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada
| | - Grace Parraga
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada.,Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Eugene Wong
- Department of Medical Biophysics, Western University, London, Ontario, Canada.,Department of Physics and Astronomy, Western University, London, Ontario, Canada
| | - Giles E Santyr
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada.,Department of Medical Biophysics, Western University, London, Ontario, Canada.,Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, Toronto, Ontario, Canada
| |
Collapse
|
44
|
Abstract
Recent developments in NMR hyperpolarization have enabled a wide array of new in vivo molecular imaging modalities, ranging from functional imaging of the lungs to metabolic imaging of cancer. This Concept article explores selected advances in methods for the preparation and use of hyperpolarized contrast agents, many of which are already at or near the phase of their clinical validation in patients.
Collapse
Affiliation(s)
- Panayiotis Nikolaou
- Institute of Imaging Science (VUIIS), Department of Radiology, Department of Biomedical Engineering, Department of Physics and Astronomy and Department of Biochemistry, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University, 1161 21st Ave South AA-1107, Nashville, Tennessee, 37232-2310 (United States)
| | - Boyd M. Goodson
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, Illinois, 62901 (United States)
| | - Eduard Y. Chekmenev
- Institute of Imaging Science (VUIIS), Department of Radiology, Department of Biomedical Engineering, Department of Physics and Astronomy and Department of Biochemistry, Vanderbilt-Ingram Cancer Center (VICC), Vanderbilt University, 1161 21st Ave South AA-1107, Nashville, Tennessee, 37232-2310 (United States)
| |
Collapse
|
45
|
Kovtunov KV, Truong ML, Barskiy D, Salnikov OG, Bukhtiyarov V, Coffey AM, Waddell KW, Koptyug IV, Chekmenev EY. Propane- d6 Heterogeneously Hyperpolarized by Parahydrogen. THE JOURNAL OF PHYSICAL CHEMISTRY. C, NANOMATERIALS AND INTERFACES 2014; 118:28234-28243. [PMID: 25506406 PMCID: PMC4259496 DOI: 10.1021/jp508719n] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2014] [Revised: 11/06/2014] [Indexed: 05/20/2023]
Abstract
Long-lived spin states of hyperpolarized propane-d6 gas were demonstrated following pairwise addition of parahydrogen gas to propene-d6 using heterogeneous parahydrogen-induced polarization (HET-PHIP). Hyperpolarized molecules were synthesized using Rh/TiO2 solid catalyst with 1.6 nm Rh nanoparticles. Hyperpolarized (PH ∼ 1%) propane-d6 was detected at high magnetic field (9.4 T) spectroscopically and by high-resolution 3D gradient-echo MRI (4.7 T) as the gas flowed through the radiofrequency coil with a spatial and temporal resolution of 0.5 × 0.5 × 0.5 mm3 and 17.7 s, respectively. Stopped-flow hyperpolarized propane-d6 gas was also detected at 0.0475 T with an observed nuclear spin polarization of PH ∼ 0.1% and a relatively long lifetime with T1,eff = 6.0 ± 0.3 s. Importantly, it was shown that the hyperpolarized protons of the deuterated product obtained via pairwise parahydrogen addition could be detected directly at low magnetic field. Importantly, the relatively long low-field T1,eff of HP propane-d6 gas is not susceptible to paramagnetic impurities as tested by exposure to ∼0.2 atm oxygen. This long lifetime and nontoxic nature of propane gas could be useful for bioimaging applications including potentially pulmonary low-field MRI. The feasibility of high-resolution low-field 2D gradient-echo MRI was demonstrated with 0.88 × 0.88 mm2 spatial and ∼0.7 s temporal resolution, respectively, at 0.0475 T.
Collapse
Affiliation(s)
- Kirill V. Kovtunov
- International
Tomography Center, 3A
Institutskaya St., Novosibirsk 630090, Russia
- Novosibirsk
State University, 2 Pirogova
St., Novosibirsk, 630090, Russia
- E-mail:
| | - Milton L. Truong
- Institute of Imaging Science, Department
of Radiology, Department of Biomedical
Engineering, Department of Physics and Astronomy, Department of Biochemistry, Vanderbilt-Ingram Cancer
Center, Vanderbilt University, Nashville, Tennessee 37232-2310, United States
| | - Danila
A. Barskiy
- International
Tomography Center, 3A
Institutskaya St., Novosibirsk 630090, Russia
- Novosibirsk
State University, 2 Pirogova
St., Novosibirsk, 630090, Russia
| | - Oleg G. Salnikov
- International
Tomography Center, 3A
Institutskaya St., Novosibirsk 630090, Russia
- Novosibirsk
State University, 2 Pirogova
St., Novosibirsk, 630090, Russia
| | - Valery
I. Bukhtiyarov
- Boreskov
Institute of Catalysis, SB RAS, 5 Acad. Lavrentiev Pr., Novosibirsk 630090, Russia
| | - Aaron M. Coffey
- Institute of Imaging Science, Department
of Radiology, Department of Biomedical
Engineering, Department of Physics and Astronomy, Department of Biochemistry, Vanderbilt-Ingram Cancer
Center, Vanderbilt University, Nashville, Tennessee 37232-2310, United States
| | - Kevin W. Waddell
- Institute of Imaging Science, Department
of Radiology, Department of Biomedical
Engineering, Department of Physics and Astronomy, Department of Biochemistry, Vanderbilt-Ingram Cancer
Center, Vanderbilt University, Nashville, Tennessee 37232-2310, United States
| | - Igor V. Koptyug
- International
Tomography Center, 3A
Institutskaya St., Novosibirsk 630090, Russia
- Novosibirsk
State University, 2 Pirogova
St., Novosibirsk, 630090, Russia
| | - Eduard Y. Chekmenev
- Institute of Imaging Science, Department
of Radiology, Department of Biomedical
Engineering, Department of Physics and Astronomy, Department of Biochemistry, Vanderbilt-Ingram Cancer
Center, Vanderbilt University, Nashville, Tennessee 37232-2310, United States
- E-mail:
| |
Collapse
|
46
|
Walkup LL, Woods JC. Translational applications of hyperpolarized 3He and 129Xe. NMR IN BIOMEDICINE 2014; 27:1429-1438. [PMID: 24953709 DOI: 10.1002/nbm.3151] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2014] [Revised: 04/07/2014] [Accepted: 05/19/2014] [Indexed: 06/03/2023]
Abstract
Clinical magnetic resonance imaging of the lung is technologically challenging, yet over the past two decades hyperpolarized noble gas ((3)He and (129)Xe) imaging has demonstrated the ability to measure multiple pulmonary functional biomarkers. There is a growing need for non-ionizing, non-invasive imaging techniques due to increased concern about cancer risk from ionizing radiation, but the translation of hyperpolarized gas imaging to the pulmonary clinic has been stunted by limited access to the technology. New developments may open doors to greater access and more translation to clinical studies. Here we briefly review a few translational applications of hyperpolarized gas MRI in the contexts of ventilation, diffusion, and dissolved-phase imaging, as well as comparing and contrasting (3)He and (129)Xe gases for these applications. Simple static ventilation MRI reveals regions of the lung not participating in normal ventilation, and these defects have been observed in many pulmonary diseases. Biomarkers related to airspace size and connectivity can be quantified by apparent diffusion coefficient measurements of hyperpolarized gas, and have been shown to be more sensitive to small changes in lung morphology than standard clinical pulmonary functional tests and have been validated by quantitative histology. Parameters related to gas uptake and exchange and lung tissue density can be determined using (129)Xe dissolved-phase MRI. In most cases functional biomarkers can be determined via MRI of either gas, but for some applications one gas may be preferred, such as (3)He for long-range diffusion measurements and (129)Xe for dissolved-phase imaging. Greater access to hyperpolarized gas imaging coupled with newly developing therapeutics makes pulmonary medicine poised for a potential revolution, further adding to the prospects of personalized medicine already evidenced by advancements in molecular biology. Hyperpolarized gas researchers have the opportunity to contribute to this revolution, particularly if greater clinical application of hyperpolarized gas imaging is realized.
Collapse
Affiliation(s)
- Laura L Walkup
- Center for Pulmonary Imaging Research, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | | |
Collapse
|
47
|
Coffey AM, Kovtunov KV, Barskiy DA, Koptyug IV, Shchepin RV, Waddell KW, He P, Groome KA, Best QA, Shi F, Goodson BM, Chekmenev EY. High-resolution low-field molecular magnetic resonance imaging of hyperpolarized liquids. Anal Chem 2014; 86:9042-9. [PMID: 25162371 PMCID: PMC4165454 DOI: 10.1021/ac501638p] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
We demonstrate the feasibility of microscale molecular imaging using hyperpolarized proton and carbon-13 MRI contrast media and low-field (47.5 mT) preclinical scale (38 mm i.d.) 2D magnetic resonance imaging (MRI). Hyperpolarized proton images with 94 × 94 μm(2) spatial resolution and hyperpolarized carbon-13 images with 250 × 250 μm(2) in-plane spatial resolution were recorded in 4-8 s (largely limited by the electronics response), surpassing the in-plane spatial resolution (i.e., pixel size) achievable with micro-positron emission tomography (PET). These hyperpolarized proton and (13)C images were recorded using large imaging matrices of up to 256 × 256 pixels and relatively large fields of view of up to 6.4 × 6.4 cm(2). (13)C images were recorded using hyperpolarized 1-(13)C-succinate-d2 (30 mM in water, %P(13C) = 25.8 ± 5.1% (when produced) and %P(13C) = 14.2 ± 0.7% (when imaged), T1 = 74 ± 3 s), and proton images were recorded using (1)H hyperpolarized pyridine (100 mM in methanol-d4, %P(H) = 0.1 ± 0.02% (when imaged), T1 = 11 ± 0.1 s). Both contrast agents were hyperpolarized using parahydrogen (>90% para-fraction) in an automated 5.75 mT parahydrogen induced polarization (PHIP) hyperpolarizer. A magnetized path was demonstrated for successful transportation of a (13)C hyperpolarized contrast agent (1-(13)C-succinate-d2, sensitive to fast depolarization when at the Earth's magnetic field) from the PHIP polarizer to the 47.5 mT low-field MRI. While future polarizing and low-field MRI hardware and imaging sequence developments can further improve the low-field detection sensitivity, the current results demonstrate that microscale molecular imaging in vivo is already feasible at low (<50 mT) fields and potentially at low (~1 mM) metabolite concentrations.
Collapse
Affiliation(s)
- Aaron M Coffey
- Vanderbilt University Institute of Imaging Science (VUIIS) and Department of Radiology, Vanderbilt University , Nashville, Tennessee 37232, United States
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Nikolaou P, Coffey AM, Barlow MJ, Rosen MS, Goodson BM, Chekmenev EY. Temperature-ramped (129)Xe spin-exchange optical pumping. Anal Chem 2014; 86:8206-12. [PMID: 25008290 PMCID: PMC4139178 DOI: 10.1021/ac501537w] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2014] [Accepted: 06/26/2014] [Indexed: 12/12/2022]
Abstract
We describe temperature-ramped spin-exchange optical pumping (TR-SEOP) in an automated high-throughput batch-mode (129)Xe hyperpolarizer utilizing three key temperature regimes: (i) "hot"-where the (129)Xe hyperpolarization rate is maximal, (ii) "warm"-where the (129)Xe hyperpolarization approaches unity, and (iii) "cool"-where hyperpolarized (129)Xe gas is transferred into a Tedlar bag with low Rb content (<5 ng per ∼1 L dose) suitable for human imaging applications. Unlike with the conventional approach of batch-mode SEOP, here all three temperature regimes may be operated under continuous high-power (170 W) laser irradiation, and hyperpolarized (129)Xe gas is delivered without the need for a cryocollection step. The variable-temperature approach increased the SEOP rate by more than 2-fold compared to the constant-temperature polarization rate (e.g., giving effective values for the exponential buildup constant γSEOP of 62.5 ± 3.7 × 10(-3) min(-1) vs 29.9 ± 1.2 × 10(-3) min(-1)) while achieving nearly the same maximum %PXe value (88.0 ± 0.8% vs 90.1% ± 0.8%, for a 500 Torr (67 kPa) Xe cell loading-corresponding to nuclear magnetic resonance/magnetic resonance imaging (NMR/MRI) enhancements of ∼3.1 × 10(5) and ∼2.32 × 10(8) at the relevant fields for clinical imaging and HP (129)Xe production of 3 T and 4 mT, respectively); moreover, the intercycle "dead" time was also significantly decreased. The higher-throughput TR-SEOP approach can be implemented without sacrificing the level of (129)Xe hyperpolarization or the experimental stability for automation-making this approach beneficial for improving the overall (129)Xe production rate in clinical settings.
Collapse
Affiliation(s)
- Panayiotis Nikolaou
- Department
of Radiology, Vanderbilt University Institute of Imaging
Science, Vanderbilt University, Nashville, Tennessee 37232, United States
| | - Aaron M. Coffey
- Department
of Radiology, Vanderbilt University Institute of Imaging
Science, Vanderbilt University, Nashville, Tennessee 37232, United States
- Department of Biomedical
Engineering, Department of Biochemistry, and Vanderbilt-Ingram
Cancer Center, Vanderbilt University, Nashville, Tennessee 37205, United States
| | - Michael J. Barlow
- Sir Peter Mansfield
Magnetic Resonance Centre, University of Nottingham, Nottingham, NG7 2RD, United Kingdom
| | - Matthew S. Rosen
- Athinoula A. Martinos
Center for Biomedical Imaging, Massachusetts General
Hospital, Boston, Massachusetts 02129, United States
- Department
of Physics, Harvard University, Cambridge, Massachusetts 02138, United States
| | - Boyd M. Goodson
- Department
of Chemistry and Biochemistry, Southern
Illinois University, Carbondale, Illinois 62901, United States
| | - Eduard Y. Chekmenev
- Department
of Radiology, Vanderbilt University Institute of Imaging
Science, Vanderbilt University, Nashville, Tennessee 37232, United States
- Department of Biomedical
Engineering, Department of Biochemistry, and Vanderbilt-Ingram
Cancer Center, Vanderbilt University, Nashville, Tennessee 37205, United States
| |
Collapse
|
49
|
Nikolaou P, Coffey AM, Ranta K, Walkup LL, Gust BM, Barlow MJ, Rosen MS, Goodson BM, Chekmenev EY. Multidimensional mapping of spin-exchange optical pumping in clinical-scale batch-mode 129Xe hyperpolarizers. J Phys Chem B 2014; 118:4809-16. [PMID: 24731261 PMCID: PMC4055050 DOI: 10.1021/jp501493k] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
![]()
We present a systematic, multiparameter
study of Rb/129Xe spin-exchange optical pumping (SEOP)
in the regimes of high xenon
pressure and photon flux using a 3D-printed, clinical-scale stopped-flow
hyperpolarizer. In situ NMR detection was used to study the dynamics
of 129Xe polarization as a function of SEOP-cell operating
temperature, photon flux, and xenon partial pressure to maximize 129Xe polarization (PXe). PXe values of 95 ± 9%, 73 ± 4%, 60
± 2%, 41 ± 1%, and 31 ± 1% at 275, 515, 1000, 1500,
and 2000 Torr Xe partial pressure were achieved. These PXe polarization values were separately validated by ejecting
the hyperpolarized 129Xe gas and performing low-field MRI
at 47.5 mT. It is shown that PXe in this
high-pressure regime can be increased beyond already record levels
with higher photon flux and better SEOP thermal management, as well
as optimization of the polarization dynamics, pointing the way to
further improvements in hyperpolarized 129Xe production
efficiency.
Collapse
Affiliation(s)
- Panayiotis Nikolaou
- Department of Radiology, Vanderbilt University Institute of Imaging Science (VUIIS) , Nashville, Tennessee 37232, United States
| | | | | | | | | | | | | | | | | |
Collapse
|