1
|
Alizadeh F, Saviz M, Khoraminia F, Talebipour A, Imani R, Shabani I. EMEMI: An interference-free mini-incubator with integrated electric and magnetic field exposure for real-time microscopic imaging of field effects. Bioelectromagnetics 2024; 45:33-47. [PMID: 37789661 DOI: 10.1002/bem.22483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 08/11/2023] [Accepted: 08/25/2023] [Indexed: 10/05/2023]
Abstract
Uninterrupted microscopic observation and real-time imaging of cell behavior during exposure to the stimulus, for example, electric and/or magnetic fields, especially for periods of several days, has been a challenge in experimental bioelectromagnetics due to a lack of proper gas/temperature conditions outside the incubator. Conventional mini-incubators might suffer from stray fields produced by heating elements. We report an in vitro electric and magnetic fields (EMF) exposure system embedded inside a novel under-the-microscope mini-CO2 -incubator with a unique design to avoid electromagnetic interference from the heating and circulation functions while ensuring the requisite temperature. A unique, reconfigurable array of electrodes and/or coils excited by calculated current distributions among array elements is designed to provide excellent field uniformity and controllable linear or circular polarization (even at very low frequencies) of the EMF within the cell culture. Using standard biochemical assays, long-term cell viability has been verified and compared with a conventional incubator. Cell orientation/migration in three-dimensional culture made of collagen-hydrogels has been successfully observed in vitro, in long-term, and in real-time under the influence of DC electric fields with the device.
Collapse
Affiliation(s)
- Farhad Alizadeh
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | - Mehrdad Saviz
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | - Farbod Khoraminia
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | - Ali Talebipour
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | - Rana Imani
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | - Iman Shabani
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| |
Collapse
|
2
|
Arora P, Tewary S, Krishnamurthi S, Kumari N. An experimental setup and segmentation method for CFU counting on agar plate for the assessment of drinking water. J Microbiol Methods 2023; 214:106829. [PMID: 37797659 DOI: 10.1016/j.mimet.2023.106829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 10/02/2023] [Accepted: 10/02/2023] [Indexed: 10/07/2023]
Abstract
Quantification of bacterial colonies on an agar plate is a daily routine for a microbiologist to determine the number of viable microorganisms in the sample. In general, microbiologists perform a visual assessment of bacterial colonies which is time-consuming (takes 2 min per plate), tedious, and subjective. Some automatic counting algorithms are developed that save labour and time, but their results are affected by the non-illumination on an agar plate. To improve this, the present manuscript aims to develop an inexpensive and efficient device to acquire S.aureus images via an automatic counting method using image processing techniques under real laboratory conditions. The proposed method (P_ColonyCount) includes the region of interest extraction and color space transformation followed by filtering, thresholding, morphological operation, distance transform, and watershed technique for the quantification of isolated and overlapping colonies. The present work also shows a comparative study on grayscale, K, and green channels by applying different filter and thresholding techniques on 42 images. The results of all channels were compared with the score provided by the expert (manual count). Out of all the proposed method (P_ColonyCount), the K channel gives the best outcome in comparison with the other two channels (grayscale and green) in terms of precision, recall, and F-measure which are 0.99, 0.99, and 0.99 (2 h), 0.98, 0.99, and 0.98 (4 h), and 0.98, 0.98, 0.98 (6 h) respectively. The execution time of the manual and the proposed method (P_ColonyCount) for 42 images ranges from 19 to 113 s and 15 to 31 s respectively. Apart from this, a user-friendly graphical user interface is also developed for the convenient enumeration of colonies without any expert knowledge/training. The developed imaging device will be useful for researchers and teaching lab settings.
Collapse
Affiliation(s)
- Prachi Arora
- Thin Film Coating Facility/Materials Science and Sensor Applications, CSIR-Central Scientific Instruments Organisation (CSIR-CSIO), Sector 30-C, Chandigarh 160030, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Suman Tewary
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India; Advanced Materials and Processes, CSIR-National Metallurgical Laboratory (CSIR-NML), Jamshedpur 831007, India
| | - Srinivasan Krishnamurthi
- MTCC-Gene bank, CSIR-Institute of Microbial Technology (CSIR-IMTECH), Sector 39-A, Chandigarh 160039, India
| | - Neelam Kumari
- Thin Film Coating Facility/Materials Science and Sensor Applications, CSIR-Central Scientific Instruments Organisation (CSIR-CSIO), Sector 30-C, Chandigarh 160030, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India.
| |
Collapse
|
3
|
Codony F, Dangla C, Ventolà L, Sabaté N. Phase change materials for portable isothermal incubators as a solution to shorten effective analysis times in microbiological quality control of drinking water. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:1105. [PMID: 37642879 DOI: 10.1007/s10661-023-11742-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 08/17/2023] [Indexed: 08/31/2023]
Abstract
The microbiological quality control of water for human consumption of parameters relevant as E.coli and total coliforms does not start on the field despite the existence of test methods that could make it possible. One of the things that makes this difficult is the possibility of initiating an effective and reliable incubation at the sampling site. The appearance of isothermal media with phase change materials solves this limitation. When phase change materials combine a relatively high melting heat with a suitable melting temperature adapted to the application temperature, they become excellent materials for thermal protection and for thermal energy storage. Starting the test at the same sampling point means that the effective times to obtain a result are shorter, improving water quality control. On the other hand, operationally, it also allows longer sampling routes. Both aspects are essential for managers responsible for controlling water quality for human consumption. In this work, the evidence that demonstrates the feasibility of this approach is presented.
Collapse
Affiliation(s)
- F Codony
- Laboratori d'Aigües de Mataró, carrer Hèl·lade, 17-19, 08304, Mataró, Barcelona, Spain.
| | - C Dangla
- Laboratori d'Aigües de Mataró, carrer Hèl·lade, 17-19, 08304, Mataró, Barcelona, Spain
| | - L Ventolà
- LVM Thermal Solutions, Carretera Vic n° 20 Nau 8, 17176 Sant Esteve d'en Bas, Barcelona, Spain
| | - N Sabaté
- Laboratori d'Aigües de Mataró, carrer Hèl·lade, 17-19, 08304, Mataró, Barcelona, Spain
| |
Collapse
|
4
|
Needs SH, Pivetal J, Hayward J, Kidd SP, Lam H, Diep T, Gill K, Woodward M, Reis NM, Edwards AD. Moving microcapillary antibiotic susceptibility testing (mcAST) towards the clinic: unravelling kinetics of detection of uropathogenic E. coli, mass-manufacturing and usability for detection of urinary tract infections in human urine. SENSORS & DIAGNOSTICS 2023; 2:736-750. [PMID: 37216011 PMCID: PMC10197089 DOI: 10.1039/d2sd00138a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 04/20/2023] [Indexed: 05/24/2023]
Abstract
Innovation in infection based point-of-care (PoC) diagnostics is vital to avoid unnecessary use of antibiotics and the development of antimicrobial resistance. Several groups including our research team have in recent years successfully miniaturised phenotypic antibiotic susceptibility tests (AST) of isolated bacterial strains, providing validation that miniaturised AST can match conventional microbiological methods. Some studies have also shown the feasibility of direct testing (without isolation or purification), specifically for urinary tract infections, paving the way for direct microfluidic AST systems at PoC. As rate of bacteria growth is intrinsically linked to the temperature of incubation, transferring miniaturised AST nearer the patient requires building new capabilities in terms of temperature control at PoC, furthermore widespread clinical use will require mass-manufacturing of microfluidic test strips and direct testing of urine samples. This study shows for the first-time application of microcapillary antibiotic susceptibility testing (mcAST) directly from clinical samples, using minimal equipment and simple liquid handling, and with kinetics of growth recorded using a smartphone camera. A complete PoC-mcAST system was presented and tested using 12 clinical samples sent to a clinical laboratory for microbiological analysis. The test showed 100% accuracy for determining bacteria in urine above the clinical threshold (5 out of 12 positive) and achieved 95% categorical agreement for 5 positive urines tested with 4 antibiotics (nitrofurantoin, ciprofloxacin, trimethoprim and cephalexin) within 6 h compared to the reference standard overnight AST method. A kinetic model is presented for metabolization of resazurin, demonstrating kinetics of degradation of resazurin in microcapillaries follow those observed for a microtiter plate, with time for AST dependent on the initial CFU ml-1 of uropathogenic bacteria in the urine sample. In addition, we show for the first time that use of air-drying for mass-manufacturing and deposition of AST reagents within the inner surface of mcAST strips matches results obtained with standard AST methods. These results take mcAST a step closer to clinical application, for example as PoC support for antibiotic prescription decisions within a day.
Collapse
Affiliation(s)
- Sarah H Needs
- Reading School of Pharmacy, University of Reading Whiteknights Campus Reading RG6 6AD UK +44(0)7906014116 +44(0)118 378 4253
| | - Jeremy Pivetal
- Reading School of Pharmacy, University of Reading Whiteknights Campus Reading RG6 6AD UK +44(0)7906014116 +44(0)118 378 4253
| | - Jessica Hayward
- Reading School of Pharmacy, University of Reading Whiteknights Campus Reading RG6 6AD UK +44(0)7906014116 +44(0)118 378 4253
| | - Stephen P Kidd
- Hampshire Hospitals NHS Foundation Trust Basingstoke and North Hampshire Hospital Basingstoke RG24 9NA UK
| | - HoYin Lam
- Hampshire Hospitals NHS Foundation Trust Basingstoke and North Hampshire Hospital Basingstoke RG24 9NA UK
| | - Tai Diep
- Reading School of Pharmacy, University of Reading Whiteknights Campus Reading RG6 6AD UK +44(0)7906014116 +44(0)118 378 4253
| | - Kiran Gill
- Reading School of Pharmacy, University of Reading Whiteknights Campus Reading RG6 6AD UK +44(0)7906014116 +44(0)118 378 4253
| | - Martin Woodward
- Department of Food and Nutrition Sciences, University of Reading Whiteknights Campus Reading RG6 6DX UK
| | - Nuno M Reis
- Department of Chemical Engineering and Centre for Biosensors, Biodevices and Bioelectronics (C3Bio), University of Bath Claverton Down Bath BA2 7AY UK +44(0)1225 383 369
- Capillary Film Technology (CFT) Daux Road Billingshurst RH14 9SJ UK
| | - Alexander D Edwards
- Reading School of Pharmacy, University of Reading Whiteknights Campus Reading RG6 6AD UK +44(0)7906014116 +44(0)118 378 4253
- Capillary Film Technology (CFT) Daux Road Billingshurst RH14 9SJ UK
| |
Collapse
|
5
|
Long MM, Diep TT, Needs SH, Ross MJ, Edwards AD. PiRamid: A compact Raspberry Pi imaging box to automate small-scale time-lapse digital analysis, suitable for laboratory and field use. HARDWAREX 2022; 12:e00377. [PMID: 36437840 PMCID: PMC9685356 DOI: 10.1016/j.ohx.2022.e00377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 11/04/2022] [Accepted: 11/12/2022] [Indexed: 06/16/2023]
Abstract
Digital imaging permits the quantitation of many experiments, such as microbiological growth assays, but laboratory digital imaging systems can be expensive and too specialised. The Raspberry Pi camera platform makes automated, controlled imaging affordable with accessible customisation. When combined with open source software and open-source 3D printed hardware, the control over image quality and capture of this platform permits the rapid development of novel instrumentation. Here we present "PiRamid", a compact, portable, and inexpensive enclosure for autonomous imaging both in the laboratory and in the field. The modular three-piece 3D printed design makes it easy to incorporate different camera systems or lighting configurations (e.g., single wavelength LED for fluorescence). The enclosed design allows complete control of illumination unlike a conventional digital camera or smartphone, on a tripod or handheld, under ambient lighting. The stackable design permits rapid sample addition or camera focus adjustment, with a corresponding change in magnification and resolution. The entire unit is small enough to fit within a microbiological incubator, and cheap enough (∼£100) to scale out for larger parallel experiments. Simply, Python scripts fully automate illumination and image capture for small-scale experiments with an ∼110×85 mm area at 70-90 µm resolution. We demonstrate the versatility of PiRamid by capturing time-resolved, quantitative image data for a wide range of assays. Bacterial growth kinetics was captured for conventional microbiology (agar Petri dishes), 3D printed custom microbiology labware and microfluidic microbiology. To illustrate application beyond microbiology, we demonstrate time-lapse imaging of crystal growth and degradation of salad leaves. Minor modifications permit epi-illumination by addition of a LED ring to the camera module. We conclude that PiRamid permits inexpensive digital capture and quantitation of a wide range of experiments by time-lapse imaging to simplify both laboratory and field imaging.
Collapse
|
6
|
Diep TT, Bizley S, Edwards AD. 3D-Printed Dip Slides Miniaturize Bacterial Identification and Antibiotic Susceptibility Tests Allowing Direct Mastitis Sample Analysis. MICROMACHINES 2022; 13:mi13060941. [PMID: 35744555 PMCID: PMC9231150 DOI: 10.3390/mi13060941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 06/08/2022] [Accepted: 06/10/2022] [Indexed: 02/04/2023]
Abstract
The early detection of antimicrobial resistance remains an essential step in the selection and optimization of antibiotic treatments. Phenotypic antibiotic susceptibility testing including the measurement of minimum inhibitory concentration (MIC) remains critical for surveillance and diagnostic testing. Limitations to current testing methods include bulky labware and laborious methods. Furthermore, the requirement of a single strain of bacteria to be isolated from samples prior to antibiotic susceptibility testing delays results. The mixture of bacteria present in a sample may also have an altered resistance profile to the individual strains, and so measuring the susceptibility of the mixtures of organisms found in some samples may be desirable. To enable simultaneous MIC and bacterial species detection in a simple and rapid miniaturized format, a 3D-printed frame was designed for a multi-sample millifluidic dip-slide device that combines panels of identification culture media with a range of antibiotics (Ampicillin, Amoxicillin, Amikacin, Ceftazidime, Cefotaxime, Ofloxacin, Oxytetracycline, Streptomycin, Gentamycin and Imipenem) diluted in Muëller-Hinton Agar. Our proof-of-concept evaluation confirmed that the direct detection of more than one bacterium parallel to measuring MIC in samples is possible, which is validated using reference strains E. coli ATCC 25922, Klebsiella pneumoniae ATCC 13883, Pseudomonas aeruginosa ATCC 10145, and Staphylococcus aureus ATCC 12600 and with mastitis milk samples collected from Reading University Farm. When mixtures were tested, a MIC value was obtained that reflected the most resistant organism present (i.e., highest MIC), suggesting it may be possible to estimate a minimum effective antibiotic concentration for mixtures directly from samples containing multiple pathogens. We conclude that this simple miniaturized approach to the rapid simultaneous identification and antibiotic susceptibility testing may be suitable for directly testing agricultural samples, which is achieved through shrinking conventional tests into a simple "dip-and-incubate" device that can be 3D printed anywhere.
Collapse
|