1
|
Menozzi L, Yao J. Deep tissue photoacoustic imaging with light and sound. NPJ IMAGING 2024; 2:44. [PMID: 39525280 PMCID: PMC11541195 DOI: 10.1038/s44303-024-00048-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Accepted: 09/23/2024] [Indexed: 11/16/2024]
Abstract
Photoacoustic computed tomography (PACT) can harvest diffusive photons to image the optical absorption contrast of molecules in a scattering medium, with ultrasonically-defined spatial resolution. PACT has been extensively used in preclinical research for imaging functional and molecular information in various animal models, with recent clinical translations. In this review, we aim to highlight the recent technical breakthroughs in PACT and the emerging preclinical and clinical applications in deep tissue imaging.
Collapse
Affiliation(s)
- Luca Menozzi
- Department of Biomedical Engineering, Duke University, Durham, NC 27708 USA
| | - Junjie Yao
- Department of Biomedical Engineering, Duke University, Durham, NC 27708 USA
- Department of Neurology, Duke University School of Medicine, Durham, NC 27710 USA
| |
Collapse
|
2
|
Neelamraju PM, Gundepudi K, Sanki PK, Busi KB, Mistri TK, Sangaraju S, Dalapati GK, Ghosh KK, Ghosh S, Ball WB, Chakrabortty S. Potential applications for photoacoustic imaging using functional nanoparticles: A comprehensive overview. Heliyon 2024; 10:e34654. [PMID: 39166037 PMCID: PMC11334826 DOI: 10.1016/j.heliyon.2024.e34654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 07/08/2024] [Accepted: 07/14/2024] [Indexed: 08/22/2024] Open
Abstract
This paper presents a comprehensive overview of the potential applications for Photo-Acoustic (PA) imaging employing functional nanoparticles. The exploration begins with an introduction to nanotechnology and nanomaterials, highlighting the advancements in these fields and their crucial role in shaping the future. A detailed discussion of the various types of nanomaterials and their functional properties sets the stage for a thorough examination of the fundamentals of the PA effect. This includes a thorough chronological review of advancements, experimental methodologies, and the intricacies of the source and detection of PA signals. The utilization of amplitude and frequency modulation, design of PA cells, pressure sensor-based signal detection, and quantification methods are explored in-depth, along with additional mechanisms induced by PA signals. The paper then delves into the versatile applications of photoacoustic imaging facilitated by functional nanomaterials. It investigates the influence of nanomaterial shape, size variation, and the role of composition, alloys, and hybrid materials in harnessing the potential of PA imaging. The paper culminates with an insightful discussion on the future scope of this field, focusing specifically on the potential applications of photoacoustic (PA) effect in the domain of biomedical imaging and nanomedicine. Finally, by providing the comprehensive overview, the current work provides a valuable resource underscoring the transformative potential of PA imaging technique in biomedical research and clinical practice.
Collapse
Affiliation(s)
- Pavan Mohan Neelamraju
- Department of Electronics and Communication Engineering, SRM University AP Andhra Pradesh, Andhra Pradesh, 522240, India
| | - Karthikay Gundepudi
- Department of Electronics and Communication Engineering, SRM University AP Andhra Pradesh, Andhra Pradesh, 522240, India
| | - Pradyut Kumar Sanki
- Department of Electronics and Communication Engineering, SRM University AP Andhra Pradesh, Andhra Pradesh, 522240, India
| | - Kumar Babu Busi
- Department of Chemistry, SRM University AP Andhra Pradesh, Andhra Pradesh, 522240, India
| | - Tapan Kumar Mistri
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur, Chennai, Tamil Nadu, 603203, India
| | - Sambasivam Sangaraju
- National Water and Energy Center, United Arab Emirates University, Al Ain, 15551, United Arab Emirates
| | - Goutam Kumar Dalapati
- Center for Nanofibers and Nanotechnology, Mechanical Engineering Department, National University of Singapore, Singapore, 117576
| | - Krishna Kanta Ghosh
- Lee Kong Chian School of Medicine, Nanyang Technological University, 59 Nanyang Drive, Singapore, 636921
| | - Siddhartha Ghosh
- Department of Physics, SRM University AP Andhra Pradesh, Andhra Pradesh, 522240, India
| | - Writoban Basu Ball
- Department of Biological Sciences, SRM University AP Andhra Pradesh, Andhra Pradesh, 522240, India
| | | |
Collapse
|
3
|
Ranjbaran SM, Zafar M, Saint-Martin L, Islam MT, Avanaki K. A practical solution to improve the field of view in circular scanning-based photoacoustic tomography. JOURNAL OF BIOPHOTONICS 2024:e202400125. [PMID: 38994672 DOI: 10.1002/jbio.202400125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 05/05/2024] [Accepted: 05/29/2024] [Indexed: 07/13/2024]
Abstract
One of the primary challenges in ring single-element photoacoustic tomography systems is the low image quality in areas away from the center of the ring. This is mainly due to the limited field of view (FOV) of each transducer, which in turn reduces the imaging FOV. To address this shortcoming, we have put forward a practical and straightforward solution to enhance the FOV of circular scanning-based photoacoustic tomography (CS-PAT). This is accomplished by placing transducers at different angles instead of using a single transducer placed at a normal angle to the imaging target. We also modified the ring scanner inner wall surface to significantly reduce photoacoustic reverberation. By imaging several phantoms, we show a significant improvement in the images generated by our system imaging from 4.1 to over 7 for the signal-to-noise ratio and structural similarity index increased from 41% to 70%.
Collapse
Affiliation(s)
- Seyed Mohsen Ranjbaran
- The Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Mohsin Zafar
- The Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Loïc Saint-Martin
- The Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Md Tarikuls Islam
- The Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Kamran Avanaki
- The Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
- Department of Dermatology, University of Illinois at Chicago, Chicago, Illinois, USA
| |
Collapse
|
4
|
Wang Y, Li C. Comprehensive framework of GPU-accelerated image reconstruction for photoacoustic computed tomography. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:066006. [PMID: 38846677 PMCID: PMC11155389 DOI: 10.1117/1.jbo.29.6.066006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 04/30/2024] [Accepted: 05/20/2024] [Indexed: 06/09/2024]
Abstract
Significance Photoacoustic computed tomography (PACT) is a promising non-invasive imaging technique for both life science and clinical implementations. To achieve fast imaging speed, modern PACT systems have equipped arrays that have hundreds to thousands of ultrasound transducer (UST) elements, and the element number continues to increase. However, large number of UST elements with parallel data acquisition could generate a massive data size, making it very challenging to realize fast image reconstruction. Although several research groups have developed GPU-accelerated method for PACT, there lacks an explicit and feasible step-by-step description of GPU-based algorithms for various hardware platforms. Aim In this study, we propose a comprehensive framework for developing GPU-accelerated PACT image reconstruction (GPU-accelerated photoacoustic computed tomography), to help the research community to grasp this advanced image reconstruction method. Approach We leverage widely accessible open-source parallel computing tools, including Python multiprocessing-based parallelism, Taichi Lang for Python, CUDA, and possible other backends. We demonstrate that our framework promotes significant performance of PACT reconstruction, enabling faster analysis and real-time applications. Besides, we also described how to realize parallel computing on various hardware configurations, including multicore CPU, single GPU, and multiple GPUs platform. Results Notably, our framework can achieve an effective rate of ∼ 871 times when reconstructing extremely large-scale three-dimensional PACT images on a dual-GPU platform compared to a 24-core workstation CPU. In this paper, we share example codes via GitHub. Conclusions Our approach allows for easy adoption and adaptation by the research community, fostering implementations of PACT for both life science and medicine.
Collapse
Affiliation(s)
- Yibing Wang
- Peking University, College of Future Technology, Department of Biomedical Engineering, Beijing, China
| | - Changhui Li
- Peking University, College of Future Technology, Department of Biomedical Engineering, Beijing, China
- Peking University, National Biomedical Imaging Center, Beijing, China
| |
Collapse
|
5
|
Zhang Y, Hu P, Li L, Cao R, Khadria A, Maslov K, Tong X, Zeng Y, Jiang L, Zhou Q, Wang LV. Ultrafast longitudinal imaging of haemodynamics via single-shot volumetric photoacoustic tomography with a single-element detector. Nat Biomed Eng 2024; 8:712-725. [PMID: 38036618 PMCID: PMC11136871 DOI: 10.1038/s41551-023-01149-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 10/25/2023] [Indexed: 12/02/2023]
Abstract
Techniques for imaging haemodynamics use ionizing radiation or contrast agents or are limited by imaging depth (within approximately 1 mm), complex and expensive data-acquisition systems, or low imaging speeds, system complexity or cost. Here we show that ultrafast volumetric photoacoustic imaging of haemodynamics in the human body at up to 1 kHz can be achieved using a single laser pulse and a single element functioning as 6,400 virtual detectors. The technique, which does not require recalibration for different objects or during long-term operation, enables the longitudinal volumetric imaging of haemodynamics in vasculature a few millimetres below the skin's surface. We demonstrate this technique in vessels in the feet of healthy human volunteers by capturing haemodynamic changes in response to vascular occlusion. Single-shot volumetric photoacoustic imaging using a single-element detector may facilitate the early detection and monitoring of peripheral vascular diseases and may be advantageous for use in biometrics and point-of-care testing.
Collapse
Affiliation(s)
- Yide Zhang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Peng Hu
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Lei Li
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Rui Cao
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Anjul Khadria
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Konstantin Maslov
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Xin Tong
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Yushun Zeng
- USC Roski Eye Institute, University of Southern California, Los Angeles, CA, USA
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
| | - Laiming Jiang
- USC Roski Eye Institute, University of Southern California, Los Angeles, CA, USA
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
| | - Qifa Zhou
- USC Roski Eye Institute, University of Southern California, Los Angeles, CA, USA
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
| | - Lihong V Wang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA.
| |
Collapse
|
6
|
Setiawan A, Huang C, Mitrayana M. Development of non-contact foreign body imaging base on photoacoustic signal intensity measurement. J Appl Clin Med Phys 2024; 25:e14230. [PMID: 38014732 PMCID: PMC11087178 DOI: 10.1002/acm2.14230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 10/25/2023] [Accepted: 11/13/2023] [Indexed: 11/29/2023] Open
Abstract
BACKGROUND It is challenging to visually identify tiny and concealed foreign objects within the body due to their small size and subcutaneous location while they can cause infections. METHODS A non-contact photoacoustic system based on Rosencwaig-Gersho photoacoustic theory and dual modulator method is developed for detecting foreign objects in meat. RESULT The experiments conducted validate the successful development of this measurement technique with 10 μm spatial resolution and its corresponding mathematical model, demonstrating an 11% Mean Absolute Percentage Error (MAPE) in comparison to the experimental results. Dual modulator successfully regulates laser energy at MPE limit. CONCLUSION The utilization of non-contact photoacoustic signal intensity measurements enables the identification of foreign objects within the body. Further, the application of mathematical modelling can validate the measurement outcomes. These findings serve as a foundation for creating an affordable and straightforward foreign body detector.
Collapse
Affiliation(s)
- Andreas Setiawan
- Department of PhysicsUniversitas Kristen Satya WacanaSalatigaIndonesia
| | - Chia‐Yi Huang
- Department of Applied PhysicsTunghai UniversityTaichungTaiwan R.O.C
| | - Mitrayana Mitrayana
- Department of PhysicsFaculty of Mathematics and Natural Sciences Universitas Gadjah MadaSekip Utara BulaksumurYogyakartaIndonesia
| |
Collapse
|
7
|
Yu Y, Feng T, Qiu H, Gu Y, Chen Q, Zuo C, Ma H. Simultaneous photoacoustic and ultrasound imaging: A review. ULTRASONICS 2024; 139:107277. [PMID: 38460216 DOI: 10.1016/j.ultras.2024.107277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Revised: 01/09/2024] [Accepted: 02/26/2024] [Indexed: 03/11/2024]
Abstract
Photoacoustic imaging (PAI) is an emerging biomedical imaging technique that combines the advantages of optical and ultrasound imaging, enabling the generation of images with both optical resolution and acoustic penetration depth. By leveraging similar signal acquisition and processing methods, the integration of photoacoustic and ultrasound imaging has introduced a novel hybrid imaging modality suitable for clinical applications. Photoacoustic-ultrasound imaging allows for non-invasive, high-resolution, and deep-penetrating imaging, providing a wealth of image information. In recent years, with the deepening research and the expanding biomedical application scenarios of photoacoustic-ultrasound bimodal systems, the immense potential of photoacoustic-ultrasound bimodal imaging in basic research and clinical applications has been demonstrated, with some research achievements already commercialized. In this review, we introduce the principles, technical advantages, and biomedical applications of photoacoustic-ultrasound bimodal imaging techniques, specifically focusing on tomographic, microscopic, and endoscopic imaging modalities. Furthermore, we discuss the future directions of photoacoustic-ultrasound bimodal imaging technology.
Collapse
Affiliation(s)
- Yinshi Yu
- Smart Computational Imaging Laboratory (SCILab), School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu Province 210094, China; Smart Computational Imaging Research Institute (SCIRI) of Nanjing University of Science and Technology, Nanjing, Jiangsu Province 210019, China; Jiangsu Key Laboratory of Spectral Imaging & Intelligent Sense, Nanjing, Jiangsu Province 210094, China
| | - Ting Feng
- Academy for Engineering & Technology, Fudan University, Shanghai 200433,China.
| | - Haixia Qiu
- First Medical Center of PLA General Hospital, Beijing, China
| | - Ying Gu
- First Medical Center of PLA General Hospital, Beijing, China
| | - Qian Chen
- Smart Computational Imaging Laboratory (SCILab), School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu Province 210094, China; Smart Computational Imaging Research Institute (SCIRI) of Nanjing University of Science and Technology, Nanjing, Jiangsu Province 210019, China; Jiangsu Key Laboratory of Spectral Imaging & Intelligent Sense, Nanjing, Jiangsu Province 210094, China
| | - Chao Zuo
- Smart Computational Imaging Laboratory (SCILab), School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu Province 210094, China; Smart Computational Imaging Research Institute (SCIRI) of Nanjing University of Science and Technology, Nanjing, Jiangsu Province 210019, China; Jiangsu Key Laboratory of Spectral Imaging & Intelligent Sense, Nanjing, Jiangsu Province 210094, China.
| | - Haigang Ma
- Smart Computational Imaging Laboratory (SCILab), School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu Province 210094, China; Smart Computational Imaging Research Institute (SCIRI) of Nanjing University of Science and Technology, Nanjing, Jiangsu Province 210019, China; Jiangsu Key Laboratory of Spectral Imaging & Intelligent Sense, Nanjing, Jiangsu Province 210094, China.
| |
Collapse
|
8
|
Nyayapathi N, Zheng E, Zhou Q, Doyley M, Xia J. Dual-modal Photoacoustic and Ultrasound Imaging: from preclinical to clinical applications. FRONTIERS IN PHOTONICS 2024; 5:1359784. [PMID: 39185248 PMCID: PMC11343488 DOI: 10.3389/fphot.2024.1359784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/27/2024]
Abstract
Photoacoustic imaging is a novel biomedical imaging modality that has emerged over the recent decades. Due to the conversion of optical energy into the acoustic wave, photoacoustic imaging offers high-resolution imaging in depth beyond the optical diffusion limit. Photoacoustic imaging is frequently used in conjunction with ultrasound as a hybrid modality. The combination enables the acquisition of both optical and acoustic contrasts of tissue, providing functional, structural, molecular, and vascular information within the same field of view. In this review, we first described the principles of various photoacoustic and ultrasound imaging techniques and then classified the dual-modal imaging systems based on their preclinical and clinical imaging applications. The advantages of dual-modal imaging were thoroughly analyzed. Finally, the review ends with a critical discussion of existing developments and a look toward the future.
Collapse
Affiliation(s)
- Nikhila Nyayapathi
- Electrical and Computer Engineering, University of Rochester, Rochester, New York, 14627
| | - Emily Zheng
- Department of Biomedical Engineering, University at Buffalo, Buffalo, New York, 14226
| | - Qifa Zhou
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90007
| | - Marvin Doyley
- Electrical and Computer Engineering, University of Rochester, Rochester, New York, 14627
| | - Jun Xia
- Department of Biomedical Engineering, University at Buffalo, Buffalo, New York, 14226
| |
Collapse
|
9
|
Fakhoury JW, Lara JB, Manwar R, Zafar M, Xu Q, Engel R, Tsoukas MM, Daveluy S, Mehregan D, Avanaki K. Photoacoustic imaging for cutaneous melanoma assessment: a comprehensive review. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S11518. [PMID: 38223680 PMCID: PMC10785699 DOI: 10.1117/1.jbo.29.s1.s11518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 12/07/2023] [Accepted: 12/21/2023] [Indexed: 01/16/2024]
Abstract
Significance Cutaneous melanoma (CM) has a high morbidity and mortality rate, but it can be cured if the primary lesion is detected and treated at an early stage. Imaging techniques such as photoacoustic (PA) imaging (PAI) have been studied and implemented to aid in the detection and diagnosis of CM. Aim Provide an overview of different PAI systems and applications for the study of CM, including the determination of tumor depth/thickness, cancer-related angiogenesis, metastases to lymph nodes, circulating tumor cells (CTCs), virtual histology, and studies using exogenous contrast agents. Approach A systematic review and classification of different PAI configurations was conducted based on their specific applications for melanoma detection. This review encompasses animal and preclinical studies, offering insights into the future potential of PAI in melanoma diagnosis in the clinic. Results PAI holds great clinical potential as a noninvasive technique for melanoma detection and disease management. PA microscopy has predominantly been used to image and study angiogenesis surrounding tumors and provide information on tumor characteristics. Additionally, PA tomography, with its increased penetration depth, has demonstrated its ability to assess melanoma thickness. Both modalities have shown promise in detecting metastases to lymph nodes and CTCs, and an all-optical implementation has been developed to perform virtual histology analyses. Animal and human studies have successfully shown the capability of PAI to detect, visualize, classify, and stage CM. Conclusions PAI is a promising technique for assessing the status of the skin without a surgical procedure. The capability of the modality to image microvasculature, visualize tumor boundaries, detect metastases in lymph nodes, perform fast and label-free histology, and identify CTCs could aid in the early diagnosis and classification of CM, including determination of metastatic status. In addition, it could be useful for monitoring treatment efficacy noninvasively.
Collapse
Affiliation(s)
- Joseph W. Fakhoury
- Wayne State University School of Medicine, Detroit, Michigan, United States
| | - Juliana Benavides Lara
- University of Illinois at Chicago, Richard and Loan Hill Department of Bioengineering, Chicago, Illinois, United States
| | - Rayyan Manwar
- University of Illinois at Chicago, Richard and Loan Hill Department of Bioengineering, Chicago, Illinois, United States
| | - Mohsin Zafar
- University of Illinois at Chicago, Richard and Loan Hill Department of Bioengineering, Chicago, Illinois, United States
| | - Qiuyun Xu
- Wayne State University, Department of Biomedical Engineering, Detroit, Michigan, United States
| | - Ricardo Engel
- Wayne State University School of Medicine, Detroit, Michigan, United States
| | - Maria M. Tsoukas
- University of Illinois at Chicago, Department of Dermatology, Chicago, Illinois, United States
| | - Steven Daveluy
- Wayne State University School of Medicine, Department of Dermatology, Detroit, Michigan, United States
| | - Darius Mehregan
- Wayne State University School of Medicine, Department of Dermatology, Detroit, Michigan, United States
| | - Kamran Avanaki
- University of Illinois at Chicago, Richard and Loan Hill Department of Bioengineering, Chicago, Illinois, United States
- University of Illinois at Chicago, Department of Dermatology, Chicago, Illinois, United States
| |
Collapse
|
10
|
Zafar M, McGuire LS, Ranjbaran SM, Matchynski JI, Manwar R, Conti AC, Perrine SA, Avanaki K. Spiral laser scanning photoacoustic microscopy for functional brain imaging in rats. NEUROPHOTONICS 2024; 11:015007. [PMID: 38344025 PMCID: PMC10855442 DOI: 10.1117/1.nph.11.1.015007] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 01/05/2024] [Accepted: 01/08/2024] [Indexed: 11/22/2024]
Abstract
Significance There are many neuroscience questions that can be answered by a high-resolution functional brain imaging system. Such a system would require the capability to visualize vasculature and measure neural activity by imaging the entire brain continually and in rapid succession in order to capture hemodynamic changes. Utilizing optical excitation and acoustic detection, photoacoustic technology enables label-free quantification of changes in endogenous chromophores, such as oxyhemoglobin, deoxyhemoglobin, and total hemoglobin. Aim Our aim was to develop a sufficiently high-resolution, fast frame-rate, and wide field-of-view (FOV) photoacoustic microscopy (PAM) system for the purpose of imaging vasculature and hemodynamics in a rat brain. Approach Although the most PA microscopy systems use raster scanning (or less commonly Lissajous scanning), we have developed a simple-to-implement laser scanning optical resolution PAM system with spiral scanning (which we have named "spiral laser scanning photoacoustic microscopy" or sLS-PAM) to acquire an 18 mm diameter image at fast frame rate (more than 1 fps). Such a system is designed to permit continuous rat brain imaging without the introduction of photobleaching artifacts. Conclusion We demonstrated the functional imaging capability of the sLS-PAM system by imaging cerebral hemodynamics in response to whisker and electrical stimulation and used it for vascular imaging of a modeled brain injury. We believe that we have demonstrated the development of a simple-to-implement PAM system, which could become an affordable functional neuroimaging tool for researchers.
Collapse
Affiliation(s)
- Mohsin Zafar
- University of Illinois at Chicago, Department of Biomedical Engineering, The Richard and Loan Hill, Chicago, Illinois, United States
| | - Laura Stone McGuire
- University of Illinois at Chicago, Department of Neurosurgery, Chicago, Illinois, United States
| | - Seyed Mohsen Ranjbaran
- University of Illinois at Chicago, Department of Biomedical Engineering, The Richard and Loan Hill, Chicago, Illinois, United States
| | - James I Matchynski
- John D. Dingell Veterans Affairs Medical Center, Detroit, Michigan, United States
- Wayne State University School of Medicine, Department of Neurosurgery, Detroit, Michigan, United States
| | - Rayyan Manwar
- University of Illinois at Chicago, Department of Biomedical Engineering, The Richard and Loan Hill, Chicago, Illinois, United States
| | - Alana C Conti
- John D. Dingell Veterans Affairs Medical Center, Detroit, Michigan, United States
- Wayne State University School of Medicine, Department of Neurosurgery, Detroit, Michigan, United States
- Wayne State University School of Medicine, Department of Psychiatry and Behavioral Neurosciences, Detroit, Michigan, United States
| | - Shane A Perrine
- John D. Dingell Veterans Affairs Medical Center, Detroit, Michigan, United States
- Wayne State University School of Medicine, Department of Neurosurgery, Detroit, Michigan, United States
- Wayne State University School of Medicine, Department of Psychiatry and Behavioral Neurosciences, Detroit, Michigan, United States
| | - Kamran Avanaki
- University of Illinois at Chicago, Department of Biomedical Engineering, The Richard and Loan Hill, Chicago, Illinois, United States
- University of Illinois at Chicago, Department of Dermatology, Chicago, Illinois, United States
| |
Collapse
|
11
|
Paul S, Mulani S, Singh MKA, Singh MS. Improvement of LED-based photoacoustic imaging using lag-coherence factor (LCF) beamforming. Med Phys 2023; 50:7525-7538. [PMID: 37843980 DOI: 10.1002/mp.16780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 09/19/2023] [Accepted: 09/20/2023] [Indexed: 10/18/2023] Open
Abstract
BACKGROUND Owing to its portability, affordability, and energy-efficiency, LED-based photoacoustic (PA) imaging is increasingly becoming popular when compared to its laser-based alternative, mainly for superficial vascular imaging applications. However, this technique suffers from low SNR and thereby limited imaging depth. As a result, visual image quality of LED-based PA imaging is not optimal, especially in sub-surface vascular imaging applications. PURPOSE Combination of linear ultrasound (US) probes and LED arrays are the most common implementation in LED-based PA imaging, which is currently being explored for different clinical imaging applications. Traditional delay-and-sum (DAS) is the most common beamforming algorithm in linear array-based PA detection. Side-lobes and reconstruction-related artifacts make the DAS performance unsatisfactory and poor for a clinical-implementation. In this work, we explored a new weighting-based image processing technique for LED-based PAs to yield improved image quality when compared to the traditional methods. METHODS We are proposing a lag-coherence factor (LCF), which is fundamentally based on the combination of the spatial auto-correlation of the detected PA signals. In LCF, the numerator contains lag-delay-multiply-and-sum (DMAS) beamformer instead of a conventional DAS beamformer. A spatial auto-correlation operation is performed between the detected US array signals before using DMAS beamformer. We evaluated the new method on both tissue-mimicking phantom (2D) and human volunteer imaging (3D) data acquired using a commercial LED-based PA imaging system. RESULTS Our novel correlation-based weighting technique showed LED-based PA image quality improvement when it is combined with conventional DAS beamformer. Both phantom and human volunteer imaging results gave a direct confirmation that by introducing LCF, image quality was improved and this method could reduce side-lobes and artifacts when compared to the DAS and coherence-factor (CF) approaches. Signal-to-noise ratio, generalized contrast-to-noise ratio, contrast ratio and spatial resolution were evaluated and compared with conventional beamformers to assess the reconstruction performance in a quantitative way. Results show that our approach offered image quality enhancement with an average signal-to-noise ratio and spatial resolution improvement of around 20% and 25% respectively, when compared with conventional CF based DAS algorithm. CONCLUSIONS Our results demonstrate that the proposed LCF based algorithm performs better than the conventional DAS and CF algorithms by improving signal-to-noise ratio and spatial resolution. Therefore, our new weighting technique could be a promising tool to improve the performance of LED-based PA imaging and thus accelerate its clinical translation.
Collapse
Affiliation(s)
- Souradip Paul
- School of physics, Indian Institute of Science Education and Research, Thiruvananthapuram, Kerala, India
| | - Sufayan Mulani
- School of physics, Indian Institute of Science Education and Research, Thiruvananthapuram, Kerala, India
| | | | | |
Collapse
|
12
|
Grishin OV, Shushunova NA, Bratashov DN, Prikhozhdenko ES, Verkhovskii RA, Kozlova AA, Abdurashitov AS, Sindeeva OA, Karavaev AS, Kulminskiy DD, Shashkov EV, Inozemtseva OA, Tuchin VV. Effect of pulsed laser parameters on photoacoustic flow cytometry efficiency in vitro and in vivo. Cytometry A 2023; 103:868-880. [PMID: 37455600 DOI: 10.1002/cyto.a.24778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 03/07/2023] [Accepted: 07/12/2023] [Indexed: 07/18/2023]
Abstract
Photoacoustic flow cytometry is one of the most effective approaches to detect "alien" objects in the bloodstream, including circulating tumor cells, blood clots, parasites, and emboli. However, the possibility of detecting high-amplitude signals from these objects against the background of blood depends on the parameters of the laser pulse. So, the dependencies of photoacoustic signals amplitude and number on laser pulse energy (5-150 μJ), pulse length (1, 2, 5 ns), and pulse repetition rate (2, 5, 10 kHz) for the melanoma cells were investigated. First, the PA responses of a melanoma cell suspension in vitro were measured to directly assess the efficiency of converting laser light into an acoustic signal. After it, the same dependence with the developed murine model based on constant rate melanoma cell injection into the animal blood flow was tested. Both in vivo and in vitro experiments show that signal generation efficiency increases with laser pulse energy above 15 μJ. Shorter pulses, especially 1 ns, provide more efficient signal generation as well as higher pulse rates. A higher pulse rate also provides more efficient signal generation, but also leads to overheating of the skin. The results show the limits where the photoacoustic flow cytometry system can be effectively used for the detection of circulating tumor cells in undiluted blood both for in vitro experiments and for in vivo murine models.
Collapse
Affiliation(s)
- Oleg V Grishin
- Science Medical Center, Saratov State University, Saratov, Russia
| | | | | | | | | | | | - Arkady S Abdurashitov
- A.V. Zelmann Center for Neurobiology and Brain Rehabilitation, Skolkovo Institute of Science and Technology, Moscow, Russia
| | - Olga A Sindeeva
- A.V. Zelmann Center for Neurobiology and Brain Rehabilitation, Skolkovo Institute of Science and Technology, Moscow, Russia
| | - Anatoly S Karavaev
- Science Medical Center, Saratov State University, Saratov, Russia
- Laboratory of Nonlinear Dynamics Modeling, Saratov Branch of the Institute of Radio-Engineering and Electronics of Russian Academy of Sciences, Saratov, Russia
- Department of Innovative Cardiological Information Technology, Institute of Cardiological Research, Saratov State Medical University, Saratov, Russia
| | - Danil D Kulminskiy
- Laboratory of Nonlinear Dynamics Modeling, Saratov Branch of the Institute of Radio-Engineering and Electronics of Russian Academy of Sciences, Saratov, Russia
- Scientific Center for Information Technologies and Artificial Intelligence, Sirius University of Science and Technology, Sochi, Russia
| | - Evgeny V Shashkov
- Pico-Femtoseconds Laser Laboratory, Photoelectronics Department, Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | | | - Valery V Tuchin
- Science Medical Center, Saratov State University, Saratov, Russia
- Laboratory of Laser Molecular Imaging and Machine Learning, Tomsk State University, Tomsk, Russia
- Institute of Precision Mechanics and Control, FRC "Saratov Scientific Centre of the Russian Academy of Sciences", Saratov, Russia
- Bach Institute of Biochemistry, FRC "Fundamentals of Biotechnology of the Russian Academy of Sciences", Moscow, Russia
| |
Collapse
|
13
|
Manwar R, Li X, Kratkiewicz K, Zhu D, Avanaki K. Adaptive coherent weighted averaging algorithm for enhancement of photoacoustic tomography images of brain. JOURNAL OF BIOPHOTONICS 2023; 16:e202300103. [PMID: 37468445 DOI: 10.1002/jbio.202300103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 06/15/2023] [Accepted: 07/03/2023] [Indexed: 07/21/2023]
Abstract
One common method to improve the low signal-to-noise ratio of the photoacoustic (PA) signal generated from weak absorbers or absorbers located in deep tissue is to acquire signal multiple times from the same region and perform averaging. However, pulse-to-pulse laser fluctuations together with differences in the beam profile of the pulses create undeterministic multiple scattering processes in the tissue. This phenomenon consequently induces a spatiotemporal displacement in the PA signal samples which in turn deteriorates the effectiveness of signal averaging. Here, we present an adaptive coherent weighted averaging algorithm to adjust the locations and values of PA signal samples for more efficient signal averaging. The proposed method is evaluated in a linear array-based PA imaging setup of ex vivo sheep brain.
Collapse
Affiliation(s)
- Rayyan Manwar
- Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Xin Li
- Department of Computer Science, Wayne State University, Detroit, Michigan, USA
| | - Karl Kratkiewicz
- Department of Biomedical Engineering, Wayne State University, Detroit, Michigan, USA
| | - Dongxiao Zhu
- Department of Computer Science, Wayne State University, Detroit, Michigan, USA
| | - Kamran Avanaki
- Richard and Loan Hill Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| |
Collapse
|
14
|
Zafar M, Manwar R, McGuire LS, Charbel FT, Avanaki K. Ultra-widefield and high-speed spiral laser scanning OR-PAM: System development and characterization. JOURNAL OF BIOPHOTONICS 2023:e202200383. [PMID: 36998211 DOI: 10.1002/jbio.202200383] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 03/01/2023] [Accepted: 03/15/2023] [Indexed: 06/19/2023]
Abstract
Photoacoustic microscopy (PAM) is a high-resolution imaging modality that has been mainly implemented with small field of view applications. Here, we developed a fast PAM system that utilizes a unique spiral laser scanning mechanism and a wide acoustic detection unit. The developed system can image an area of 12.5 cm2 in 6.4 s. The system has been characterized using highly detailed phantoms. Finally, the imaging capabilities of the system were further demonstrated by imaging a sheep brain ex vivo and a rat brain in vivo.
Collapse
Affiliation(s)
- Mohsin Zafar
- The Richard and Loan Hill, Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
- Department of Biomedical Engineering, Wayne State University, Detroit, Michigan, USA
| | - Rayyan Manwar
- The Richard and Loan Hill, Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Laura S McGuire
- Department of Neurological Surgery, University of Illinois at Chicago - College of Medicine, Chicago, Illinois, USA
| | - Fady T Charbel
- Department of Neurological Surgery, University of Illinois at Chicago - College of Medicine, Chicago, Illinois, USA
| | - Kamran Avanaki
- The Richard and Loan Hill, Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
- Department of Dermatology, University of Illinois at Chicago, Chicago, Illinois, USA
| |
Collapse
|
15
|
Zhang Y, Hu P, Li L, Cao R, Khadria A, Maslov K, Tong X, Zeng Y, Jiang L, Zhou Q, Wang LV. Single-shot 3D photoacoustic tomography using a single-element detector for ultrafast imaging of hemodynamics. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.03.14.532661. [PMID: 36993341 PMCID: PMC10055152 DOI: 10.1101/2023.03.14.532661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 04/29/2023]
Abstract
Imaging hemodynamics is crucial for the diagnosis, treatment, and prevention of vascular diseases. However, current imaging techniques are limited due to the use of ionizing radiation or contrast agents, short penetration depth, or complex and expensive data acquisition systems. Photoacoustic tomography shows promise as a solution to these issues. However, existing photoacoustic tomography methods collect signals either sequentially or through numerous detector elements, leading to either low imaging speed or high system complexity and cost. To address these issues, here we introduce a method to capture a 3D photoacoustic image of vasculature using a single laser pulse and a single-element detector that functions as 6,400 virtual ones. Our method enables ultrafast volumetric imaging of hemodynamics in the human body at up to 1 kHz and requires only a single calibration for different objects and for long-term operations. We demonstrate 3D imaging of hemodynamics at depth in humans and small animals, capturing the variability in blood flow speeds. This concept can inspire other imaging technologies and find applications such as home-care monitoring, biometrics, point-of-care testing, and wearable monitoring.
Collapse
Affiliation(s)
- Yide Zhang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Peng Hu
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Lei Li
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Rui Cao
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Anjul Khadria
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Konstantin Maslov
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Xin Tong
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Yushun Zeng
- Department of Biomedical Engineering and Ophthalmology, University of Southern California, Los Angeles, CA 90089, USA
| | - Laiming Jiang
- Department of Biomedical Engineering and Ophthalmology, University of Southern California, Los Angeles, CA 90089, USA
| | - Qifa Zhou
- Department of Biomedical Engineering and Ophthalmology, University of Southern California, Los Angeles, CA 90089, USA
| | - Lihong V. Wang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| |
Collapse
|
16
|
Menozzi L, Yang W, Feng W, Yao J. Sound out the impaired perfusion: Photoacoustic imaging in preclinical ischemic stroke. Front Neurosci 2022; 16:1055552. [PMID: 36532279 PMCID: PMC9751426 DOI: 10.3389/fnins.2022.1055552] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Accepted: 11/17/2022] [Indexed: 09/19/2023] Open
Abstract
Acoustically detecting the optical absorption contrast, photoacoustic imaging (PAI) is a highly versatile imaging modality that can provide anatomical, functional, molecular, and metabolic information of biological tissues. PAI is highly scalable and can probe the same biological process at various length scales ranging from single cells (microscopic) to the whole organ (macroscopic). Using hemoglobin as the endogenous contrast, PAI is capable of label-free imaging of blood vessels in the brain and mapping hemodynamic functions such as blood oxygenation and blood flow. These imaging merits make PAI a great tool for studying ischemic stroke, particularly for probing into hemodynamic changes and impaired cerebral blood perfusion as a consequence of stroke. In this narrative review, we aim to summarize the scientific progresses in the past decade by using PAI to monitor cerebral blood vessel impairment and restoration after ischemic stroke, mostly in the preclinical setting. We also outline and discuss the major technological barriers and challenges that need to be overcome so that PAI can play a more significant role in preclinical stroke research, and more importantly, accelerate its translation to be a useful clinical diagnosis and management tool for human strokes.
Collapse
Affiliation(s)
- Luca Menozzi
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Wei Yang
- Multidisciplinary Brain Protection Program, Department of Anesthesiology, Duke University, Durham, NC, United States
| | - Wuwei Feng
- Department of Neurology, Duke University School of Medicine, Durham, NC, United States
| | - Junjie Yao
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| |
Collapse
|
17
|
Fu L, Khazaeinezhad R, Hariri A, Qi B, Chen C, Jokerst JV. Posterior photoacoustic/ultrasound imaging of the periodontal pocket with a compact intraoral transducer. PHOTOACOUSTICS 2022; 28:100408. [PMID: 36204181 PMCID: PMC9530592 DOI: 10.1016/j.pacs.2022.100408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 08/15/2022] [Accepted: 09/25/2022] [Indexed: 06/16/2023]
Abstract
Periodontitis is a public issue and imaging periodontal pocket is important to evaluate periodontitis. Regular linear transducers have limitations in imaging the posterior teeth due to their geometry restrictions. Here we characterized a transducer that can image the posterior teeth including assessment of periodontal pockets via a combination of photoacoustic and ultrasound imaging. Unlike conventional transducer design, this device has a toothbrush-shaped form factor with a side-view transducer to image molars (total size: 1 ×1.9 cm). A laser diode was integrated as the light source to reduce the cost and size and facilitates clinical transition. The in vivo imaging of a molar of a periodontal patient demonstrated that the transducer could image in the posterior area of gum in vivo; the value determined by imaging was within 7 % of the value measured clinically.
Collapse
Affiliation(s)
- Lei Fu
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA
| | | | - Ali Hariri
- StyloSonic LLC, Lake Forest, CA 92630, USA
| | - Baiyan Qi
- Materials Science and Engineering Program, University of California San Diego, La Jolla, CA 92093, USA
| | - Casey Chen
- Herman Ostrow School of Dentistry, University of Southern California, 925 West 34th Street, Los Angeles, CA 90089, USA
| | - Jesse V. Jokerst
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA
- StyloSonic LLC, Lake Forest, CA 92630, USA
- Materials Science and Engineering Program, University of California San Diego, La Jolla, CA 92093, USA
- Department of Radiology, University of California San Diego, La Jolla, CA 92093, USA
| |
Collapse
|
18
|
Tong G, Luzgin A, Xia J, Xu L, Zhang H, Dong C, Wu Z, Wu J, Zhang Y, Qin P. Improved photoacoustic images via wavefront shaping modulation based on the scattering structure. OPTICS EXPRESS 2022; 30:36489-36499. [PMID: 36258576 DOI: 10.1364/oe.470330] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Accepted: 09/04/2022] [Indexed: 06/16/2023]
Abstract
Multispectral optoacoustic tomography (MSOT) has become the dominant technical solution for photoacoustic imaging (PAI). However, the laser source of fiber output in the current MSOT method is typically a TEM00 Gaussian beam, which is prone to artifacts and incomplete due to the uneven distribution of the irradiated light intensity. Here, we propose a novel method to improve the quality of photoacoustic image reconstruction by modulating the wavefront shaping of the incident laser beam based on the designed scattering structure. In the experiment, we add the designed scattering structure to the current hemispherical photoacoustic transducer array device. Through experiments and simulations, we investigate and compare the effects of different scattering structures on laser intensity modulation. The results show that an ED1-C20 diffusion structure with a scattering angle of 20 degrees has the most effective modulation of the beam intensity distribution. And we choose gold nanoparticles of 50-100 nanometers (nm) diameters and index finger capillary vessels respectively as the medium of PAI. We obtain the highest ratio of PAI area increases of gold nanoparticles and index finger to devices compare without scattering structure is 29.69% and 634.94%, respectively. Experimental results demonstrate that our method is significantly higher quality than traditional methods, which has great potential for theoretical application in medical PAI.
Collapse
|
19
|
Ghanbarzadeh-Dagheyan A, Nili VA, Ejtehadi M, Savabi R, Kavehvash Z, Ahmadian MT, Vahdat BV. Time-domain ultrasound as prior information for frequency-domain compressive ultrasound for intravascular cell detection: A 2-cell numerical model. ULTRASONICS 2022; 125:106791. [PMID: 35809517 DOI: 10.1016/j.ultras.2022.106791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Revised: 05/05/2022] [Accepted: 06/08/2022] [Indexed: 06/15/2023]
Abstract
This study proposes a new method for the detection of a weak scatterer among strong scatterers using prior-information ultrasound (US) imaging. A perfect application of this approach is in vivo cell detection in the bloodstream, where red blood cells (RBCs) serve as identifiable strong scatterers. In vivo cell detection can help diagnose cancer at its earliest stages, increasing the chances of survival for patients. This work combines time-domain US with frequency-domain compressive US imaging to detect a 20-μ MCF-7 circulating tumor cell (CTC) among a number of RBCs within a simulated venule inside the mouth. The 2D image reconstructed from the time-domain US is employed to simulate the reflected and scattered pressure field from the RBCs, which is then measured at the location of the receivers. The RBCs are tagged one time by a human operator and another time, automatically, by template-based computer vision. Next, the resulting signal from the RBCs is subtracted from the measured total signal in frequency domain to generate the scattered-field data, coming from the CTC alone. Feeding that signal and the background pressure field into a norm-one-based compressive sensing code enables detecting the CTC at various locations. As errors could arise in determining the location of the RBCs and their acoustic properties in the real world, small errors (up to 10% in the former and 5% in the latter) are purposefully introduced to the model, to which the proposed method is shown to be resilient. Localization errors are smaller than 12 μ when a human tags the RBCs and smaller than 25 μ when computer vision is applied. Despite its limitations, this study, for the first time, reports the results of combining two US modalities aimed at cell detection and introduces a unique and useful application for ultrahigh-frequency US imaging. It should be noted that this method can be used in detecting weak scatterers with ultrasound waves in other applications as well.
Collapse
Affiliation(s)
- Ashkan Ghanbarzadeh-Dagheyan
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran; Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran.
| | - Vahid Amin Nili
- Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
| | - Mehdi Ejtehadi
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Reza Savabi
- School of Mechanical Engineering, University of Tehran, Tehran, Iran
| | - Zahra Kavehvash
- Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
| | | | | |
Collapse
|
20
|
Tutorial on Development of 3D Vasculature Digital Phantoms for Evaluation of Photoacoustic Image Reconstruction Algorithms. PHOTONICS 2022. [DOI: 10.3390/photonics9080538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
A synthetic phantom model is typically utilized to evaluate the initial performance of a photoacoustic image reconstruction algorithm. The characteristics of the phantom model (structural, optical, and acoustic) are required to be very similar to those of the biological tissue. Typically, generic two-dimensional shapes are used as imaging targets to calibrate reconstruction algorithms. However, these structures are not representative of complex biological tissue, and therefore the artifacts that exist in reconstructed images of biological tissue vasculature are ignored. Real data from 3D MRI/CT volumes can be extrapolated to create high-quality phantom models; however, these sometimes involve complicated pre-processing and mostly are challenging, due to the inaccessibility of these datasets or the requirement for approval to utilize the data. Therefore, it is necessary to develop a 3D tissue-mimicking phantom model consisting of different compartments with characteristics that can be easily modified. In this tutorial, we present an optimized development process of a generic 3D complex digital vasculature phantom model in Blender. The proposed workflow is such that an accurate and easily editable digital phantom can be developed. Other workflows for creating the same phantom will take much longer to set up and require more time to edit. We have made a few examples of editable 3D phantom models, which are publicly available to test and modify.
Collapse
|
21
|
Fu L, Jokerst J. Interleave-sampled photoacoustic imaging: a doubled and equivalent sampling rate for high-frequency imaging. OPTICS LETTERS 2022; 47:3503-3506. [PMID: 35838713 PMCID: PMC10100578 DOI: 10.1364/ol.464293] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Accepted: 06/16/2022] [Indexed: 06/15/2023]
Abstract
High-frequency photoacoustic (PA) imaging (>20 MHz) requires data acquisition (DAQ) with a commensurately high sampling rate, which leads to hardware challenges and increased costs. We report here a new, to the best of our knowledge, method-interleave-sampled PA imaging-that enables high-frequency imaging with a relatively low sampling rate, e.g., a 41.67-MHz sampling rate with a 30-MHz transducer. This method harnesses two acquisitions at a low sampling rate to effectively double the sampling rate which consequently reduces the frame rate by a factor of two. It modulates the delay of the light pulses and can thus be applied to any PA DAQ system. We perform both phantom and in vivo studies with a 30-MHz transducer. The results demonstrate that interleaved sampling at 41.67 MHz can capture high frequency information above 30 MHz but a conventional 41.67-MHz sampling rate cannot. The axial and lateral resolution are as high as 63 µm and 91 µm via interleaved sampling which are much higher than those of conventional 41.67-MHz sampling (130 µm and 136 µm).
Collapse
Affiliation(s)
- Lei Fu
- Department of NanoEngineering, University of California San Diego, La Jolla, California 92093, USA
| | - Jesse Jokerst
- Department of NanoEngineering, University of California San Diego, La Jolla, California 92093, USA
- Material Science and Engineering Program, University of California San Diego, La Jolla, California 92093, USA
- Department of Radiology, University of California San Diego, La Jolla, California 92093, USA
| |
Collapse
|
22
|
Jiang D, Lan H, Wang Y, Shen Y, Gao F, Gao F. Programmable Acoustic Delay-Line Enabled Low-Cost Photoacoustic Tomography System. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2075-2084. [PMID: 35412979 DOI: 10.1109/tuffc.2022.3166841] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Photoacoustic tomography (PAT) is an emerging technology for biomedical imaging that combines the superiorities of high optical contrast and acoustic penetration. In the PAT system, more PA signals are preferred to be detected from full field of view to reconstruct the PA images with higher fidelity. However, the requirement for more PA signals' detection leads to more time consumption for single-channel scanning-based PAT system or higher cost of data acquisition (DAQ) module for an array-based PAT system. To address this issue, we proposed a programmable acoustic delay-line (PADL) module to reduce DAQ cost and accelerate imaging speed for PAT system. The module is based on bidirectional conversion between acoustic signals and electrical signals, including ultrasound transmission in between to provide sufficient time delay. The acoustic delay-line module achieves tens or hundreds of microseconds' delay for each channel and is controlled by a programmable control unit. In this work, it achieves to merge four inputs of PA signals into one output signal, which can be recovered into original four PA signals in the digital domain after DAQ. The imaging experiments of pencil leads embedded in agar phantom are conducted by the PAT system equipped with the proposed PADL module, which demonstrated its feasibility to reduce the cost of the PAT system. An in vivo study of human finger PAT imaging with delay-line module verified its feasibility for biomedical imaging applications.
Collapse
|
23
|
Photoacoustic Imaging in Biomedicine and Life Sciences. Life (Basel) 2022; 12:life12040588. [PMID: 35455079 PMCID: PMC9028050 DOI: 10.3390/life12040588] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 02/19/2022] [Indexed: 12/25/2022] Open
Abstract
Photo-acoustic imaging, also known as opto-acoustic imaging, has become a widely popular modality for biomedical applications. This hybrid technique possesses the advantages of high optical contrast and high ultrasonic resolution. Due to the distinct optical absorption properties of tissue compartments and main chromophores, photo-acoustics is able to non-invasively observe structural and functional variations within biological tissues including oxygenation and deoxygenation, blood vessels and spatial melanin distribution. The detection of acoustic waves produced by a pulsed laser source yields a high scaling range, from organ level photo-acoustic tomography to sub-cellular or even molecular imaging. This review discusses significant novel technical solutions utilising photo-acoustics and their applications in the fields of biomedicine and life sciences.
Collapse
|
24
|
Kim H, Kim JY, Cho S, Ahn J, Kim Y, Kim H, Kim C. Performance comparison of high-speed photoacoustic microscopy: opto-ultrasound combiner versus ring-shaped ultrasound transducer. Biomed Eng Lett 2022; 12:147-153. [PMID: 35529340 PMCID: PMC9046515 DOI: 10.1007/s13534-022-00218-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 01/04/2022] [Accepted: 01/26/2022] [Indexed: 12/17/2022] Open
Abstract
Photoacoustic microscopy (PAM) embedded with a 532 nm pulse laser is widely used to visualize the microvascular structures in both small animals and humans in vivo. An opto-ultrasound combiner (OUC) is often utilized in high-speed PAM to confocally align the optical and acoustic beams to improve the system's sensitivity. However, acoustic impedance mismatch in the OUC results in little improvement in the sensitivity. Alternatively, a ring-shaped ultrasound transducer (RUT) can also accomplish the confocal configuration. Here, we compare the performance of OUC and RUT modules through ultrasound pulse-echo tests and PA imaging experiments. The signal-to-noise ratios (SNRs) of the RUT-based system were 15 dB, 12 dB, and 7 dB higher when compared to the OUC-based system for ultrasound pulse-echo test, PA phantom imaging test, and PA in-vivo imaging test, respectively. In addition, the RUT-based system could image the microvascular structures of small parts of a mouse body in a few seconds with minimal loss in SNR. Thus, with increased sensitivity, improved image details, and fast image acquisition, we believe the RUT-based systems could play a significant role in the design of future fast-PAM systems.
Collapse
Affiliation(s)
- Hyojin Kim
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Interdisciplinary Bioscience and Bioengineering, Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673 Republic of Korea
| | - Jin Young Kim
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Interdisciplinary Bioscience and Bioengineering, Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673 Republic of Korea
| | - Seonghee Cho
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Interdisciplinary Bioscience and Bioengineering, Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673 Republic of Korea
| | - Joongho Ahn
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Interdisciplinary Bioscience and Bioengineering, Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673 Republic of Korea
| | - Yeonggeun Kim
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Interdisciplinary Bioscience and Bioengineering, Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673 Republic of Korea
| | - Hyungham Kim
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Interdisciplinary Bioscience and Bioengineering, Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673 Republic of Korea
| | - Chulhong Kim
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Interdisciplinary Bioscience and Bioengineering, Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk 37673 Republic of Korea
| |
Collapse
|
25
|
Manwar R, Islam MT, Ranjbaran SM, Avanaki K. Transfontanelle photoacoustic imaging: ultrasound transducer selection analysis. BIOMEDICAL OPTICS EXPRESS 2022; 13:676-693. [PMID: 35284180 PMCID: PMC8884197 DOI: 10.1364/boe.446087] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 12/23/2021] [Accepted: 12/24/2021] [Indexed: 05/11/2023]
Abstract
Transfontanelle ultrasound imaging (TFUI) is the conventional approach for diagnosing brain injury in neonates. Despite being the first stage imaging modality, TFUI lacks accuracy in determining the injury at an early stage due to degraded sensitivity and specificity. Therefore, a modality like photoacoustic imaging that combines the advantages of both acoustic and optical imaging can overcome the existing TFUI limitations. Even though a variety of transducers have been used in TFUI, it is essential to identify the transducer specification that is optimal for transfontanelle imaging using the photoacoustic technique. In this study, we evaluated the performance of 6 commercially available ultrasound transducer arrays to identify the optimal characteristics for transfontanelle photoacoustic imaging. We focused on commercially available linear and phased array transducer probes with center frequencies ranging from 2.5MHz to 8.5MHz which covers the entire spectrum of the transducer arrays used for brain imaging. The probes were tested on both in vitro and ex vivo brain tissue, and their performance in terms of transducer resolution, size, penetration depth, sensitivity, signal to noise ratio, signal amplification and reconstructed image quality were evaluated. The analysis of selected transducers in these areas allowed us to determine the optimal transducer for transfontanelle imaging, based on vasculature depth and blood density in tissue using ex vivo sheep brain. The outcome of this evaluation identified the two most suitable ultrasound transducer probes for transfontanelle photoacoustic imaging.
Collapse
Affiliation(s)
- Rayyan Manwar
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, USA
- These authors have contributed equally
| | - Md Tarikul Islam
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, USA
| | - Seyed Mohsen Ranjbaran
- Department of Physics, University of Isfahan, Isfahan 81746-73441, Iran
- These authors have contributed equally
| | - Kamran Avanaki
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, USA
- Department of Dermatology, University of Illinois at Chicago, Chicago, Illinois 60607, USA
| |
Collapse
|
26
|
Fu B, Cheng Y, Shang C, Li J, Wang G, Zhang C, Sun J, Ma J, Ji X, He B. Optical ultrasound sensors for photoacoustic imaging: a narrative review. Quant Imaging Med Surg 2022; 12:1608-1631. [PMID: 35111652 DOI: 10.21037/qims-21-605] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 09/23/2021] [Indexed: 11/06/2022]
Abstract
Optical ultrasound sensors have been increasingly employed in biomedical diagnosis and photoacoustic imaging (PAI) due to high sensitivity and resolution. PAI could visualize the distribution of ultrasound excited by laser pulses in biological tissues. The information of tissues is detected by ultrasound sensors in order to reconstruct structural images. However, traditional ultrasound transducers are made of piezoelectric films that lose sensitivity quadratically with the size reduction. In addition, the influence of electromagnetic interference limits further applications of traditional ultrasound transducers. Therefore, optical ultrasound sensors are developed to overcome these shortcomings. In this review, optical ultrasound sensors are classified into resonant and non-resonant ones in view of physical principles. The principles and basic parameters of sensors are introduced in detail. Moreover, the state of the art of optical ultrasound sensors and applications in PAI are also presented. Furthermore, the merits and drawbacks of sensors based on resonance and non-resonance are discussed in perspectives. We believe this review could provide researchers with a better understanding of the current status of optical ultrasound sensors and biomedical applications.
Collapse
Affiliation(s)
- Bo Fu
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.,School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China.,Key Laboratory of Big Data-Based Precision Medicine, Ministry of Industry and Information Technology, Interdisciplinary Innovation Institute of Medicine and Engineering, Beihang University, Beijing, China
| | - Yuan Cheng
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
| | - Ce Shang
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.,School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Jing Li
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.,School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Gang Wang
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
| | - Chenghong Zhang
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
| | - Jingxuan Sun
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
| | - Jianguo Ma
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.,School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China.,Key Laboratory of Big Data-Based Precision Medicine, Ministry of Industry and Information Technology, Interdisciplinary Innovation Institute of Medicine and Engineering, Beihang University, Beijing, China
| | - Xunming Ji
- Neurosurgery Department of Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Boqu He
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.,School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
| |
Collapse
|
27
|
Zhao YJ, Zhu XL, Luo PY, Li A, Xiao W, Xiao X, Liu L, Meng MQH. Development of a Compact Photoacoustic Tomography Imaging System with Dual Single-Element Transducers for Image Enhancement. Curr Med Sci 2021; 41:1151-1157. [PMID: 34907474 DOI: 10.1007/s11596-021-2482-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Accepted: 11/19/2021] [Indexed: 11/27/2022]
Abstract
OBJECTIVE This paper proposes a new photoacoustic computed tomography (PACT) imaging system employing dual ultrasonic transducers with different frequencies. When imaging complex biological tissues, photoacoustic (PA) signals with multiple frequencies are produced simultaneously; however, due to the limited bandwidth of a single-frequency transducer, the received PA signals with specific frequencies may be missing, leading to a low imaging quality. METHODS In contrast to our previous work, the proposed system has a compact volume as well as specific selection of the detection center frequency of the transducer, which can provide a comprehensive range for the detection of PA signals. In this study, a series of numerical simulation and phantom experiments were performed to validate the efficacy of the developed PACT system. RESULTS The images generated by our system combined the advantages of both high resolution and ideal brightness/contrast. CONCLUSION The interchangeability of transducers with different frequencies provides potential for clinical deployment under the circumstance where a single frequency transducer cannot perform well.
Collapse
Affiliation(s)
- Yong-Jian Zhao
- Department of Electronic and Electrical Engineering, the Southern University of Science and Technology, Shenzhen, 518055, China
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, 999077, China
| | - Xiao-Long Zhu
- Department of Electronic and Electrical Engineering, the Southern University of Science and Technology, Shenzhen, 518055, China
| | - Pei-Yu Luo
- Department of Electronic and Electrical Engineering, the Southern University of Science and Technology, Shenzhen, 518055, China
| | - Ang Li
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, 999077, China
| | - Wei Xiao
- Department of Electronic and Electrical Engineering, the Southern University of Science and Technology, Shenzhen, 518055, China
| | - Xiao Xiao
- Department of Electronic and Electrical Engineering, the Southern University of Science and Technology, Shenzhen, 518055, China
| | - Li Liu
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, 999077, China.
| | - Max Q-H Meng
- Department of Electronic and Electrical Engineering, the Southern University of Science and Technology, Shenzhen, 518055, China.
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, 999077, China.
- Shenzhen Research Institute of The Chinese University of Hong Kong in Shenzhen, Shenzhen, 518172, China.
| |
Collapse
|
28
|
Jeong S, Yoo SW, Kim HJ, Park J, Kim JW, Lee C, Kim H. Recent Progress on Molecular Photoacoustic Imaging with Carbon-Based Nanocomposites. MATERIALS (BASEL, SWITZERLAND) 2021; 14:5643. [PMID: 34640053 PMCID: PMC8510032 DOI: 10.3390/ma14195643] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 09/25/2021] [Accepted: 09/27/2021] [Indexed: 12/20/2022]
Abstract
For biomedical imaging, the interest in noninvasive imaging methods is ever increasing. Among many modalities, photoacoustic imaging (PAI), which is a combination of optical and ultrasound imaging techniques, has received attention because of its unique advantages such as high spatial resolution, deep penetration, and safety. Incorporation of exogenous imaging agents further amplifies the effective value of PAI, since they can deliver other specified functions in addition to imaging. For these agents, carbon-based materials can show a large specific surface area and interesting optoelectronic properties, which increase their effectiveness and have proved their potential in providing a theragnostic platform (diagnosis + therapy) that is essential for clinical use. In this review, we introduce the current state of the PAI modality, address recent progress on PAI imaging that takes advantage of carbon-based agents, and offer a future perspective on advanced PAI systems using carbon-based agents.
Collapse
Affiliation(s)
- Songah Jeong
- School of Polymer Science and Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea; (S.J.); (H.J.K.); (J.P.); (J.W.K.)
| | - Su Woong Yoo
- Department of Nuclear Medicine, Chonnam National University Hwasun Hospital, 264, Seoyang-ro, Hwasun-eup, Hwasun-gun 58128, Jeollanam-do, Korea;
| | - Hea Ji Kim
- School of Polymer Science and Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea; (S.J.); (H.J.K.); (J.P.); (J.W.K.)
| | - Jieun Park
- School of Polymer Science and Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea; (S.J.); (H.J.K.); (J.P.); (J.W.K.)
| | - Ji Woo Kim
- School of Polymer Science and Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea; (S.J.); (H.J.K.); (J.P.); (J.W.K.)
| | - Changho Lee
- Department of Nuclear Medicine, Chonnam National University Hwasun Hospital, 264, Seoyang-ro, Hwasun-eup, Hwasun-gun 58128, Jeollanam-do, Korea;
- Department of Nuclear Medicine, Chonnam National University Medical School, 160, Baekseo-ro, Dong-gu, Gwangju 61469, Korea
- Department of Artificial Intelligence Convergence, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea
| | - Hyungwoo Kim
- School of Polymer Science and Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea; (S.J.); (H.J.K.); (J.P.); (J.W.K.)
| |
Collapse
|
29
|
Abstract
Photoacoustic imaging is a new type of noninvasive, nonradiation imaging modality that combines the deep penetration of ultrasonic imaging and high specificity of optical imaging. Photoacoustic imaging systems employing conventional ultrasonic sensors impose certain constraints such as obstructions in the optical path, bulky sensor size, complex system configurations, difficult optical and acoustic alignment, and degradation of signal-to-noise ratio. To overcome these drawbacks, an ultrasonic sensor in the optically transparent form has been introduced, as it enables direct delivery of excitation light through the sensors. In recent years, various types of optically transparent ultrasonic sensors have been developed for photoacoustic imaging applications, including optics-based ultrasonic sensors, piezoelectric-based ultrasonic sensors, and microelectromechanical system-based capacitive micromachined ultrasonic transducers. In this paper, the authors review representative transparent sensors for photoacoustic imaging applications. In addition, the potential challenges and future directions of the development of transparent sensors are discussed.
Collapse
|
30
|
Na S, Wang LV. Photoacoustic computed tomography for functional human brain imaging [Invited]. BIOMEDICAL OPTICS EXPRESS 2021; 12:4056-4083. [PMID: 34457399 PMCID: PMC8367226 DOI: 10.1364/boe.423707] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 06/05/2021] [Accepted: 06/08/2021] [Indexed: 05/02/2023]
Abstract
The successes of magnetic resonance imaging and modern optical imaging of human brain function have stimulated the development of complementary modalities that offer molecular specificity, fine spatiotemporal resolution, and sufficient penetration simultaneously. By virtue of its rich optical contrast, acoustic resolution, and imaging depth far beyond the optical transport mean free path (∼1 mm in biological tissues), photoacoustic computed tomography (PACT) offers a promising complementary modality. In this article, PACT for functional human brain imaging is reviewed in its hardware, reconstruction algorithms, in vivo demonstration, and potential roadmap.
Collapse
Affiliation(s)
- Shuai Na
- Caltech Optical Imaging Laboratory, Andrew
and Peggy Cherng Department of Medical Engineering,
California Institute of Technology, 1200
East California Boulevard, Pasadena, CA 91125, USA
| | - Lihong V. Wang
- Caltech Optical Imaging Laboratory, Andrew
and Peggy Cherng Department of Medical Engineering,
California Institute of Technology, 1200
East California Boulevard, Pasadena, CA 91125, USA
- Caltech Optical Imaging Laboratory,
Department of Electrical Engineering, California
Institute of Technology, 1200 East California Boulevard,
Pasadena, CA 91125, USA
| |
Collapse
|
31
|
Joseph J, Ajith Singh MK, Sato N, Bohndiek SE. Technical validation studies of a dual-wavelength LED-based photoacoustic and ultrasound imaging system. PHOTOACOUSTICS 2021; 22:100267. [PMID: 33948434 PMCID: PMC8080074 DOI: 10.1016/j.pacs.2021.100267] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 03/01/2021] [Accepted: 04/06/2021] [Indexed: 05/12/2023]
Abstract
Recent advances in high power, pulsed, light emitting diodes (LEDs) have shown potential as fast, robust and relatively inexpensive excitation sources for photoacoustic imaging (PAI), yet systematic characterization of performance for biomedical imaging is still lacking. We report here technical and biological validation studies of a commercial dual-wavelength LED-based PAI and ultrasound system. Phantoms and small animals were used to assess temporal precision. In phantom studies, we found high temporal stability of the LED-based PAI system, with no significant drift in performance observed during 6 h of operation or over 30 days of repeated measurements. In vivo dual-wavelength imaging was able to map the dynamics of changes in blood oxygenation during oxygen-enhanced imaging and reveal the kinetics of indocyanine green contrast agent inflow after intravenous administration (Tmax∼6 min). Taken together, these studies indicate that LED-based excitation could be promising for future application in functional and molecular PAI.
Collapse
Affiliation(s)
- James Joseph
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge, CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge, CB2 0RE, UK
- Now at School of Science and Engineering, Fulton Building, University of Dundee, DD1 4HN, UK
| | | | - Naoto Sato
- Research and Development Division, CYBERDYNE INC, Tsukuba, 305-0818, Japan
| | - Sarah E. Bohndiek
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge, CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge, CB2 0RE, UK
| |
Collapse
|
32
|
Yao J, Wang LV. Perspective on fast-evolving photoacoustic tomography. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210105-PERR. [PMID: 34196136 PMCID: PMC8244998 DOI: 10.1117/1.jbo.26.6.060602] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 06/17/2021] [Indexed: 05/19/2023]
Abstract
SIGNIFICANCE Acoustically detecting the rich optical absorption contrast in biological tissues, photoacoustic tomography (PAT) seamlessly bridges the functional and molecular sensitivity of optical excitation with the deep penetration and high scalability of ultrasound detection. As a result of continuous technological innovations and commercial development, PAT has been playing an increasingly important role in life sciences and patient care, including functional brain imaging, smart drug delivery, early cancer diagnosis, and interventional therapy guidance. AIM Built on our 2016 tutorial article that focused on the principles and implementations of PAT, this perspective aims to provide an update on the exciting technical advances in PAT. APPROACH This perspective focuses on the recent PAT innovations in volumetric deep-tissue imaging, high-speed wide-field microscopic imaging, high-sensitivity optical ultrasound detection, and machine-learning enhanced image reconstruction and data processing. Representative applications are introduced to demonstrate these enabling technical breakthroughs in biomedical research. CONCLUSIONS We conclude the perspective by discussing the future development of PAT technologies.
Collapse
Affiliation(s)
- Junjie Yao
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States
| | - Lihong V. Wang
- California Institute of Technology, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, Pasadena, California, United States
| |
Collapse
|
33
|
Ringel MJ, Tang EM, Tao YK. Advances in multimodal imaging in ophthalmology. Ther Adv Ophthalmol 2021; 13:25158414211002400. [PMID: 35187398 PMCID: PMC8855415 DOI: 10.1177/25158414211002400] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 02/23/2021] [Indexed: 12/12/2022] Open
Abstract
Multimodality ophthalmic imaging systems aim to enhance the contrast, resolution, and functionality of existing technologies to improve disease diagnostics and therapeutic guidance. These systems include advanced acquisition and post-processing methods using optical coherence tomography (OCT), combined scanning laser ophthalmoscopy and OCT systems, adaptive optics, surgical guidance, and photoacoustic technologies. Here, we provide an overview of these ophthalmic imaging systems and their clinical and basic science applications.
Collapse
Affiliation(s)
- Morgan J. Ringel
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Eric M. Tang
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Yuankai K. Tao
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA
| |
Collapse
|
34
|
Chandramoorthi S, Thittai AK. Extending Imaging Depth in PLD-Based Photoacoustic Imaging: Moving Beyond Averaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:549-557. [PMID: 32784132 DOI: 10.1109/tuffc.2020.3015130] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Pulsed laser diodes (PLDs) promise to be an attractive alternative to solid-state laser sources in photoacoustic tomography (PAT) due to their portability, high-pulse repetition frequency (PRF), and cost effectiveness. However, due to their lower energy per pulse, which, in turn, results in lower fluence required per photoacoustic signal generation, PLD-based photoacoustic systems generally have maximum imaging depth that is lower in comparison to solid-state lasers. Averaging of multiple frames is usually employed as a common practice in high PRF PLD systems to improve the signal-to-noise ratio of the PAT images. In this work, we demonstrate that by combining the recently described approach of subpitch translation on the receive-side ultrasound transducer alongside averaging of multiple frames, it is feasible to increase the depth sensitivity in a PLD-based PAT imaging system. Here, experiments on phantom containing diluted India ink targets were performed at two different laser energy level settings, that is, 21 and [Formula: see text]. Results obtained showed that the imaging depth improves by ~38.5% from 9.1 to 12.6 mm for 21- [Formula: see text] energy level setting and by ~33.3% from 10.8 to 14.4 mm for 27- [Formula: see text] energy level setting by using λ /4-pitch translation and average of 128 frames in comparison to λ -pitch data acquired with the average of 128 frames. However, the achievable frame rate is reduced by a factor of 2 and 4 for λ /2 and λ /4 subpitch translation, respectively.
Collapse
|
35
|
Kratkiewicz K, Manwar R, Zhou Y, Mozaffarzadeh M, Avanaki K. Technical considerations in the Verasonics research ultrasound platform for developing a photoacoustic imaging system. BIOMEDICAL OPTICS EXPRESS 2021; 12:1050-1084. [PMID: 33680559 PMCID: PMC7901326 DOI: 10.1364/boe.415481] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 12/23/2020] [Accepted: 12/23/2020] [Indexed: 05/20/2023]
Abstract
Photoacoustic imaging (PAI) is an emerging functional and molecular imaging technology that has attracted much attention in the past decade. Recently, many researchers have used the vantage system from Verasonics for simultaneous ultrasound (US) and photoacoustic (PA) imaging. This was the motivation to write on the details of US/PA imaging system implementation and characterization using Verasonics platform. We have discussed the experimental considerations for linear array based PAI due to its popularity, simple setup, and high potential for clinical translatability. Specifically, we describe the strategies of US/PA imaging system setup, signal generation, amplification, data processing and study the system performance.
Collapse
Affiliation(s)
- Karl Kratkiewicz
- Wayne State University, Department of
Biomedical Engineering, Detroit, MI 48201, USA
- These authors have contributed
equally
| | - Rayyan Manwar
- Richard and Loan Hill Department of
Bioengineering, University of Illinois at Chicago, IL 60607, USA
- These authors have contributed
equally
| | - Yang Zhou
- Wayne State University, Department of
Biomedical Engineering, Detroit, MI 48201, USA
| | - Moein Mozaffarzadeh
- Laboratory of Medical Imaging, Department
of Imaging Physics, Delft University of Technology, The Netherlands
| | - Kamran Avanaki
- Richard and Loan Hill Department of
Bioengineering, University of Illinois at Chicago, IL 60607, USA
| |
Collapse
|
36
|
Abstract
Purpose: Photoacoustics (optoacoustics) is a hybrid technology utilizing light excitation of acoustic responses in targets of interest. It has found numerous applications in biomedicine, including eye research, because of its ability to report both morphological and functional data about the interrogated tissue. This presentation will give an overview of current applications. Methods: Wavelength-dependent absorption of light in a tissue chromophore causes local heating, leading to a thermoelastic expansion-contraction cycle. If nanosecond pulses of light are used to excite this process, the resulting pressure wave is an ultrasound signal propagating through the tissue and detectable at the tissue surface. This is highly advantageous because of the known properties of ultrasound propagation in tissue and the ability to use standard, medical ultrasound equipment for detection. The time of arrival and amplitude of ultrasound signals provide information about the location and nature of the absorber. Results: Due to the wavelength dependence of the photoacoustic response, functional and physiological applications are possible. For example, retinal oximetry can be determined from the different optical absorption properties of oxy- and deoxyhemoglobin. Multispectral imaging of the posterior segment can identify pigments such as melanin or lipofuscin or the nature of foreign bodies. The technique can be combined with other imaging modalities such as ultrasound and optical coherence tomography to produce high-resolution images of retinal structures along with functional information. Conclusion: Photoacoustic technology is a powerful noninvasive tool for ocular research and to study ocular morphology, fundamental physiological parameters, cellular responses, and molecular expression.
Collapse
Affiliation(s)
- Randolph D Glickman
- Department of Ophthalmology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| |
Collapse
|
37
|
Rodrigues HF, Capistrano G, Bakuzis AF. In vivo magnetic nanoparticle hyperthermia: a review on preclinical studies, low-field nano-heaters, noninvasive thermometry and computer simulations for treatment planning. Int J Hyperthermia 2021; 37:76-99. [PMID: 33426989 DOI: 10.1080/02656736.2020.1800831] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Magnetic nanoparticle hyperthermia (MNH) is a promising nanotechnology-based cancer thermal therapy that has been approved for clinical use, together with radiation therapy, for treating brain tumors. Almost ten years after approval, few new clinical applications had appeared, perhaps because it cannot benefit from the gold standard noninvasive MRI thermometry technique, since static magnetic fields inhibit heat generation. This might limit its clinical use, in particular as a single therapeutic modality. In this article, we review the in vivo MNH preclinical studies, discussing results of the last two decades with emphasis on safety as a clinical criteria, the need for low-field nano-heaters and noninvasive thermal dosimetry, and the state of the art of computational modeling for treatment planning using MNH. Limitations to more effective clinical use are discussed, together with suggestions for future directions, such as the development of ultrasound-based, computed tomography-based or magnetic nanoparticle-based thermometry to achieve greater impact on clinical translation of MNH.
Collapse
Affiliation(s)
- Harley F Rodrigues
- Instituto de Física, Universidade Federal de Goiás, Goiânia, Brasil.,Curso de Licenciatura em Física, Instituto Federal de Goiás, Goiânia, Brasil
| | - Gustavo Capistrano
- Instituto de Física, Universidade Federal de Goiás, Goiânia, Brasil.,Campus Fronteira Oeste, Instituto Federal de Mato Grosso, Pontes e Lacerda, Brasil
| | - Andris F Bakuzis
- Instituto de Física, Universidade Federal de Goiás, Goiânia, Brasil
| |
Collapse
|
38
|
Hessler M, Jalilian E, Xu Q, Reddy S, Horton L, Elkin K, Manwar R, Tsoukas M, Mehregan D, Avanaki K. Melanoma Biomarkers and Their Potential Application for In Vivo Diagnostic Imaging Modalities. Int J Mol Sci 2020; 21:E9583. [PMID: 33339193 PMCID: PMC7765677 DOI: 10.3390/ijms21249583] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 12/09/2020] [Accepted: 12/12/2020] [Indexed: 12/16/2022] Open
Abstract
Melanoma is the deadliest form of skin cancer and remains a diagnostic challenge in the dermatology clinic. Several non-invasive imaging techniques have been developed to identify melanoma. The signal source in each of these modalities is based on the alteration of physical characteristics of the tissue from healthy/benign to melanoma. However, as these characteristics are not always sufficiently specific, the current imaging techniques are not adequate for use in the clinical setting. A more robust way of melanoma diagnosis is to "stain" or selectively target the suspect tissue with a melanoma biomarker attached to a contrast enhancer of one imaging modality. Here, we categorize and review known melanoma diagnostic biomarkers with the goal of guiding skin imaging experts to design an appropriate diagnostic tool for differentiating between melanoma and benign lesions with a high specificity and sensitivity.
Collapse
Affiliation(s)
- Monica Hessler
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA; (M.H.); (Q.X.); (S.R.); (L.H.); (K.E.); (R.M.)
- Department of Dermatology, School of Medicine, Wayne State University School of Medicine, Detroit, MI 48201, USA;
| | - Elmira Jalilian
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, IL 60607, USA;
| | - Qiuyun Xu
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA; (M.H.); (Q.X.); (S.R.); (L.H.); (K.E.); (R.M.)
| | - Shriya Reddy
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA; (M.H.); (Q.X.); (S.R.); (L.H.); (K.E.); (R.M.)
| | - Luke Horton
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA; (M.H.); (Q.X.); (S.R.); (L.H.); (K.E.); (R.M.)
- Department of Dermatology, School of Medicine, Wayne State University School of Medicine, Detroit, MI 48201, USA;
| | - Kenneth Elkin
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA; (M.H.); (Q.X.); (S.R.); (L.H.); (K.E.); (R.M.)
- Department of Dermatology, School of Medicine, Wayne State University School of Medicine, Detroit, MI 48201, USA;
| | - Rayyan Manwar
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA; (M.H.); (Q.X.); (S.R.); (L.H.); (K.E.); (R.M.)
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| | - Maria Tsoukas
- Department of Dermatology, University of Illinois at Chicago, Chicago, IL 60607, USA;
| | - Darius Mehregan
- Department of Dermatology, School of Medicine, Wayne State University School of Medicine, Detroit, MI 48201, USA;
| | - Kamran Avanaki
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA
- Department of Dermatology, University of Illinois at Chicago, Chicago, IL 60607, USA;
| |
Collapse
|
39
|
Zhou J, Jokerst JV. Photoacoustic imaging with fiber optic technology: A review. PHOTOACOUSTICS 2020; 20:100211. [PMID: 33163358 PMCID: PMC7606844 DOI: 10.1016/j.pacs.2020.100211] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 09/05/2020] [Accepted: 09/19/2020] [Indexed: 05/03/2023]
Abstract
Photoacoustic imaging (PAI) has achieved remarkable growth in the past few decades since it takes advantage of both optical and ultrasound (US) imaging. In order to better promote the wide clinical applications of PAI, many miniaturized and portable PAI systems have recently been proposed. Most of these systems utilize fiber optic technologies. Here, we overview the fiber optic technologies used in PAI. This paper discusses three different fiber optic technologies: fiber optic light transmission, fiber optic US transmission, and fiber optic US detection. These fiber optic technologies are analyzed in different PAI modalities including photoacoustic microscopy (PAM), photoacoustic computed tomography (PACT), and minimally invasive photoacoustic imaging (MIPAI).
Collapse
Affiliation(s)
- Jingcheng Zhou
- Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, USA
| | - Jesse V. Jokerst
- Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, USA
- Materials Science and Engineering Program, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, USA
- Department of Radiology, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, USA
| |
Collapse
|
40
|
Kuniyil Ajith Singh M, Xia W. Portable and Affordable Light Source-Based Photoacoustic Tomography. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6173. [PMID: 33138296 PMCID: PMC7663770 DOI: 10.3390/s20216173] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 10/27/2020] [Accepted: 10/28/2020] [Indexed: 12/27/2022]
Abstract
Photoacoustic imaging is a hybrid imaging modality that offers the advantages of optical (spectroscopic contrast) and ultrasound imaging (scalable spatial resolution and imaging depth). This promising modality has shown excellent potential in a wide range of preclinical and clinical imaging and sensing applications. Even though photoacoustic imaging technology has matured in research settings, its clinical translation is not happening at the expected pace. One of the main reasons for this is the requirement of bulky and expensive pulsed lasers for excitation. To accelerate the clinical translation of photoacoustic imaging and explore its potential in resource-limited settings, it is of paramount importance to develop portable and affordable light sources that can be used as the excitation light source. In this review, we focus on the following aspects: (1) the basic theory of photoacoustic imaging; (2) inexpensive light sources and different implementations; and (3) important preclinical and clinical applications, demonstrated using affordable light source-based photoacoustics. The main focus will be on laser diodes and light-emitting diodes as they have demonstrated promise in photoacoustic tomography-the key technological developments in these areas will be thoroughly reviewed. We believe that this review will be a useful opus for both the beginners and experts in the field of biomedical photoacoustic imaging.
Collapse
Affiliation(s)
- Mithun Kuniyil Ajith Singh
- Research and Business Development Division, CYBERDYNE INC., Stationsplein 45, A4.004, 3013 AK Rotterdam, The Netherlands;
| | - Wenfeng Xia
- School of Biomedical Engineering& Imaging Sciences, King’s College London, King’s Health Partners, St Thomas’ Hospital, London SE1 7EH, UK
| |
Collapse
|
41
|
Zhan Y, Singh Rathore A, Milione G, Wang Y, Zheng W, Xu W, Xia J. 3D finger vein biometric authentication with photoacoustic tomography. APPLIED OPTICS 2020; 59:8751-8758. [PMID: 33104557 DOI: 10.1364/ao.400550] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 08/24/2020] [Indexed: 06/11/2023]
Abstract
Biometric authentication is the recognition of human identity via unique anatomical features. The development of novel methods parallels widespread application by consumer devices, law enforcement, and access control. In particular, methods based on finger veins, as compared to face and fingerprints, obviate privacy concerns and degradation due to wear, age, and obscuration. However, they are two-dimensional (2D) and are fundamentally limited by conventional imaging and tissue-light scattering. In this work, for the first time, to the best of our knowledge, we demonstrate a method of three-dimensional (3D) finger vein biometric authentication based on photoacoustic tomography. Using a compact photoacoustic tomography setup and a novel recognition algorithm, the advantages of 3D are demonstrated via biometric authentication of index finger vessels with false acceptance, false rejection, and equal error rates <1.23%, <9.27%, and <0.13%, respectively, when comparing one finger, a false acceptance rateimprovement>10× when comparing multiple fingers, and <0.7% when rotating fingers ±30.
Collapse
|
42
|
Amorim CA, Blanco KC, Costa IM, de Araújo EP, Arantes ADN, Contiero J, Chiquito AJ. A New Possibility for Fermentation Monitoring by Electrical Driven Sensing of Ultraviolet Light and Glucose. BIOSENSORS-BASEL 2020; 10:bios10080097. [PMID: 32806501 PMCID: PMC7459838 DOI: 10.3390/bios10080097] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Revised: 07/21/2020] [Accepted: 07/23/2020] [Indexed: 12/14/2022]
Abstract
Industrial fermentation generates products through microbial growth associated with the consumption of substrates. The efficiency of industrial production of high commercial value microbial products such as ethanol from glucose (GLU) is dependent on bacterial contamination. Controlling the sugar conversion into products as well as the sterility of the fermentation process are objectives to be considered here by studying GLU and ultraviolet light (UV) sensors. In this work, we present two different approaches of SnO2 nanowires grown by the Vapor–Liquid–Solid (VLS) method. In the GLU sensor, we use SnO2 nanowires as active electrodes, while for the UV sensor, a nanowire film was built for detection. The results showed a wide range of GLU sensing and as well as a significant influence of UV in the electrical signal. The effect of a wide range of GLU concentrations on the responsiveness of the sensor through current–voltage based on SnO2 nanowire films under different concentration conditions ranging was verified from 1 to 1000 mmol. UV sensors show a typical amperometric response of SnO2 nanowires under the excitation of UV and GLU in ten cycles of 300 s with 1.0 V observing a stable and reliable amperometric response. GLU and UV sensors proved to have a promising potential for detection and to control the conversion of a substrate into a product by GLU control and decontamination by UV control in industrial fermentation systems.
Collapse
Affiliation(s)
- Cleber A. Amorim
- School of Sciences and Engineering, Av. Domingos da Costa Lopes, São Paulo State University (Unesp), 780 Jardim Itaipu, CEP 17602-496 Tupã, SP, Brazil;
| | - Kate C. Blanco
- São Carlos Institute of Physics, University of São Paulo—Box 369, 13566-970, São Carlos, SP, Brazil;
| | - Ivani M. Costa
- NanOLaB, Departamento de Física, Universidade Federal de São Carlos—UFSCar, Rodovia Washington Luiz, Km 235 Monjolinho, CP 676, CEP 13565-905 São Carlos, SP, Brazil; (I.M.C.); (E.P.d.A.); (A.d.N.A.); (A.J.C.)
- Institute of Chemistry, Araraquara. Rua Professor Francisco Degni, São Paulo State University (Unesp), Jardim Quitandinha, CEP 14800-060 Araraquara, SP, Brazil
| | - Estácio P. de Araújo
- NanOLaB, Departamento de Física, Universidade Federal de São Carlos—UFSCar, Rodovia Washington Luiz, Km 235 Monjolinho, CP 676, CEP 13565-905 São Carlos, SP, Brazil; (I.M.C.); (E.P.d.A.); (A.d.N.A.); (A.J.C.)
| | - Adryelle do Nascimento Arantes
- NanOLaB, Departamento de Física, Universidade Federal de São Carlos—UFSCar, Rodovia Washington Luiz, Km 235 Monjolinho, CP 676, CEP 13565-905 São Carlos, SP, Brazil; (I.M.C.); (E.P.d.A.); (A.d.N.A.); (A.J.C.)
| | - Jonas Contiero
- Institute of Biosciences, Department of General and Applied Biology, São Paulo State University (Unesp), Rio Claro, Rio Claro, Av. 24-A, 1515 Bela Vista, CEP 13506-692 Rio Claro, SP, Brazil
- Institute for Research in Bioenergy, São Paulo State University (Unesp) Rua 10, 2527 Santana, CEP 13500-230 Rio Claro, SP, Brazil
- Correspondence: ; Tel.: +55-(019)-35264149
| | - Adenilson J. Chiquito
- NanOLaB, Departamento de Física, Universidade Federal de São Carlos—UFSCar, Rodovia Washington Luiz, Km 235 Monjolinho, CP 676, CEP 13565-905 São Carlos, SP, Brazil; (I.M.C.); (E.P.d.A.); (A.d.N.A.); (A.J.C.)
| |
Collapse
|
43
|
Manwar R, Kratkiewicz K, Avanaki K. Investigation of the Effect of the Skull in Transcranial Photoacoustic Imaging: A Preliminary Ex Vivo Study. SENSORS (BASEL, SWITZERLAND) 2020; 20:E4189. [PMID: 32731449 PMCID: PMC7435985 DOI: 10.3390/s20154189] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 07/16/2020] [Accepted: 07/22/2020] [Indexed: 01/17/2023]
Abstract
Although transcranial photoacoustic imaging (TCPAI) has been used in small animal brain imaging, in animals with thicker skull bones or in humans both light illumination and ultrasound propagation paths are affected. Hence, the PA image is largely degraded and in some cases completely distorted. This study aims to investigate and determine the maximum thickness of the skull through which photoacoustic imaging is feasible in terms of retaining the imaging target structure without incorporating any post processing. We identify the effect of the skull on both the illumination path and acoustic propagation path separately and combined. In the experimental phase, the distorting effect of ex vivo sheep skull bones with thicknesses in the range of 0.7~1.3 mm are explored. We believe that the findings in this study facilitate the clinical translation of TCPAI.
Collapse
Affiliation(s)
- Rayyan Manwar
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA;
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA;
| | - Karl Kratkiewicz
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA;
| | - Kamran Avanaki
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA;
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA;
- Department of Dermatology, University of Illinois at Chicago, Chicago, IL 60607, USA
| |
Collapse
|
44
|
Manwar R, Kratkiewicz K, Avanaki K. Overview of Ultrasound Detection Technologies for Photoacoustic Imaging. MICROMACHINES 2020; 11:E692. [PMID: 32708869 PMCID: PMC7407969 DOI: 10.3390/mi11070692] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 07/14/2020] [Accepted: 07/14/2020] [Indexed: 12/15/2022]
Abstract
Ultrasound detection is one of the major components of photoacoustic imaging systems. Advancement in ultrasound transducer technology has a significant impact on the translation of photoacoustic imaging to the clinic. Here, we present an overview on various ultrasound transducer technologies including conventional piezoelectric and micromachined transducers, as well as optical ultrasound detection technology. We explain the core components of each technology, their working principle, and describe their manufacturing process. We then quantitatively compare their performance when they are used in the receive mode of a photoacoustic imaging system.
Collapse
Affiliation(s)
- Rayyan Manwar
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA;
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA;
| | - Karl Kratkiewicz
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA;
| | - Kamran Avanaki
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA;
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA;
- Department of Dermatology, University of Illinois at Chicago, Chicago, IL 60607, USA
| |
Collapse
|
45
|
Farnia P, Najafzadeh E, Hariri A, Lavasani SN, Makkiabadi B, Ahmadian A, Jokerst JV. Dictionary learning technique enhances signal in LED-based photoacoustic imaging. BIOMEDICAL OPTICS EXPRESS 2020; 11:2533-2547. [PMID: 32499941 PMCID: PMC7249823 DOI: 10.1364/boe.387364] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Revised: 03/18/2020] [Accepted: 03/18/2020] [Indexed: 05/12/2023]
Abstract
There has been growing interest in low-cost light sources such as light-emitting diodes (LEDs) as an excitation source in photoacoustic imaging. However, LED-based photoacoustic imaging is limited by low signal due to low energy per pulse-the signal is easily buried in noise leading to low quality images. Here, we describe a signal de-noising approach for LED-based photoacoustic signals based on dictionary learning with an alternating direction method of multipliers. This signal enhancement method is then followed by a simple reconstruction approach delay and sum. This approach leads to sparse representation of the main components of the signal. The main improvements of this approach are a 38% higher contrast ratio and a 43% higher axial resolution versus the averaging method but with only 4% of the frames and consequently 49.5% less computational time. This makes it an appropriate option for real-time LED-based photoacoustic imaging.
Collapse
Affiliation(s)
- Parastoo Farnia
- Medical Physics and Biomedical Engineering Department, Faculty of Medicine, Tehran University of Medical Sciences (TUMS), Tehran, Iran
- Research Centre of Biomedical Technology and Robotics (RCBTR), Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
- These authors contributed equally to this paper
| | - Ebrahim Najafzadeh
- Medical Physics and Biomedical Engineering Department, Faculty of Medicine, Tehran University of Medical Sciences (TUMS), Tehran, Iran
- Research Centre of Biomedical Technology and Robotics (RCBTR), Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
- These authors contributed equally to this paper
| | - Ali Hariri
- Department of Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, USA
| | - Saeedeh Navaei Lavasani
- Research Centre of Biomedical Technology and Robotics (RCBTR), Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
- Department of Biomedical Engineering and Medical Physics, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Bahador Makkiabadi
- Medical Physics and Biomedical Engineering Department, Faculty of Medicine, Tehran University of Medical Sciences (TUMS), Tehran, Iran
- Research Centre of Biomedical Technology and Robotics (RCBTR), Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
| | - Alireza Ahmadian
- Medical Physics and Biomedical Engineering Department, Faculty of Medicine, Tehran University of Medical Sciences (TUMS), Tehran, Iran
- Research Centre of Biomedical Technology and Robotics (RCBTR), Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
| | - Jesse V. Jokerst
- Department of Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, USA
- Materials Science and Engineering Program, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, USA
- Department of Radiology, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, USA
| |
Collapse
|
46
|
Joseph Francis K, Boink YE, Dantuma M, Ajith Singh MK, Manohar S, Steenbergen W. Tomographic imaging with an ultrasound and LED-based photoacoustic system. BIOMEDICAL OPTICS EXPRESS 2020; 11:2152-2165. [PMID: 32341873 PMCID: PMC7173893 DOI: 10.1364/boe.384548] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 01/15/2020] [Accepted: 01/22/2020] [Indexed: 05/05/2023]
Abstract
Pulsed lasers in photoacoustic tomography systems are expensive, which limit their use to a few clinics and small animal labs. We present a method to realize tomographic ultrasound and photoacoustic imaging using a commercial LED-based photoacoustic and ultrasound system. We present two illumination configurations using LED array units and an optimal number of angular views for tomographic reconstruction. The proposed method can be a cost-effective solution for applications demanding tomographic imaging and can be easily integrated into conventional linear array-based ultrasound systems. We present a potential application for finger joint imaging in vivo, which can be used for point-of-care rheumatoid arthritis diagnosis and monitoring.
Collapse
Affiliation(s)
- Kalloor Joseph Francis
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
- Multi-Modality Medical Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Yoeri E. Boink
- Multi-Modality Medical Imaging Group, Technical Medical Center, University of Twente, The Netherlands
- Department of Applied Mathematics, University of Twente, The Netherlands
| | - Maura Dantuma
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
- Multi-Modality Medical Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Mithun Kuniyil Ajith Singh
- Research and Business Development Division, CYBERDYNE INC, Cambridge Innovation Center, Rotterdam, The Netherlands
| | - Srirang Manohar
- Multi-Modality Medical Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Wiendelt Steenbergen
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| |
Collapse
|
47
|
Regensburger AP, Wagner AL, Claussen J, Waldner MJ, Knieling F. Shedding light on pediatric diseases: multispectral optoacoustic tomography at the doorway to clinical applications. Mol Cell Pediatr 2020; 7:3. [PMID: 32130546 PMCID: PMC7056767 DOI: 10.1186/s40348-020-00095-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Accepted: 02/24/2020] [Indexed: 12/25/2022] Open
Abstract
Optoacoustic imaging (OAI), or photoacoustic imaging (PAI), has fundamentally influenced basic science by providing high-resolution visualization of biological mechanisms. With the introduction of multispectral optoacoustic tomography (MSOT), these technologies have now moved closer to clinical applications. MSOT utilizes short-pulsed near-infrared laser light to induce thermoelastic expansion in targeted tissues. This results in acoustic pressure waves, which are used to resolve specific endo- and exogenous chromophores. Especially in the pediatric population, this non-invasive imaging approach might hold fundamental advantages compared to conventional cross-sectional imaging modalities. As this technology allows the visualization of quantitative molecular tissue composition at high spatial resolution non-invasively in sufficient penetration depth, it paves the way to personalized medicine in pediatric diseases.
Collapse
Affiliation(s)
- Adrian P Regensburger
- Pediatric Experimental and Translational Imaging Laboratory (PETI-Lab), Department of Pediatrics and Adolescent Medicine, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, Loschgestraße 15, 91054, Erlangen, Germany
| | - Alexandra L Wagner
- Pediatric Experimental and Translational Imaging Laboratory (PETI-Lab), Department of Pediatrics and Adolescent Medicine, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, Loschgestraße 15, 91054, Erlangen, Germany
| | - Jing Claussen
- Pediatric Experimental and Translational Imaging Laboratory (PETI-Lab), Department of Pediatrics and Adolescent Medicine, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, Loschgestraße 15, 91054, Erlangen, Germany
| | - Maximilian J Waldner
- Medical Department 1, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, Erlangen, Germany
| | - Ferdinand Knieling
- Pediatric Experimental and Translational Imaging Laboratory (PETI-Lab), Department of Pediatrics and Adolescent Medicine, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg, Loschgestraße 15, 91054, Erlangen, Germany.
| |
Collapse
|
48
|
The Acquisition Rate and Soundness of a Low-Cost Data Acquisition System (LC-DAQ) for High Frequency Applications. SENSORS 2020; 20:s20020524. [PMID: 31963552 PMCID: PMC7014543 DOI: 10.3390/s20020524] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 01/10/2020] [Accepted: 01/14/2020] [Indexed: 11/16/2022]
Abstract
This article presents a novel and reliable low-cost data acquisition solution for high frequency and real-time applications in vehicular dynamics. Data acquisition systems for highly dynamic systems based on low-cost platforms face different challenges such as a constrained data retrieval rate. Basic data reading functions in these platforms are inefficient and, when used, they limit electronics acquisition rate capabilities. This paper explains a new low-cost, modular and open platform to read different types of sensors at high speed rates. Conventional reading functions are avoided to speed up acquisition rate, but this negatively affects data reliability of the system. To solve this and exploit higher data managing rates, a number of custom secure layers are implemented to secure a reliable acquisition. This paper describes the new low-cost electronics developed for high rate acquisition applications and inspects its performance and robustness against the introduction of an increasing number of sensors connected to the board. In most cases, acquisition rates of the system are duplicated using this new solution.
Collapse
|
49
|
Development of a Stationary 3D Photoacoustic Imaging System Using Sparse Single-Element Transducers: Phantom Study. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9214505] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Photoacoustic imaging (PAI) is an emerging label-free and non-invasive modality for imaging biological tissues. PAI has been implemented in different configurations, one of which is photoacoustic computed tomography (PACT) with a potential wide range of applications, including brain and breast imaging. Hemispherical Array PACT (HA-PACT) is a variation of PACT that has solved the limited detection-view problem. Here, we designed an HA-PACT system consisting of 50 single element transducers. For implementation, we initially performed a simulation study, with parameters close to those in practice, to determine the relationship between the number of transducers and the quality of the reconstructed image. We then used the greatest number of transducers possible on the hemisphere and imaged copper wire phantoms coated with a light absorbing material to evaluate the performance of the system. Several practical issues such as light illumination, arrangement of the transducers, and an image reconstruction algorithm have been comprehensively studied.
Collapse
|