1
|
Woraganjanaboon P, Senawongse P, Anunmana C. A two-year clinical trial of enamel wear opposing 5Y-TZP and lithium disilicate crowns. J Prosthet Dent 2024:S0022-3913(24)00472-4. [PMID: 39138093 DOI: 10.1016/j.prosdent.2024.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Revised: 06/30/2024] [Accepted: 07/09/2024] [Indexed: 08/15/2024]
Abstract
STATEMENT OF PROBLEM Clinical information on enamel wear opposing 5 mol% yttria-stabilized tetragonal zirconia polycrystal (5Y-TZP) or lithium disilicate crowns is lacking. Moreover, the effect of surface roughness on the wear of enamel antagonists remains unclear. PURPOSE The purpose of this clinical study was to quantify the vertical wear and total volume of wear while also measuring the surface roughness of antagonists at 6-month intervals over 2 years. MATERIAL AND METHODS A tooth-supported first molar 5Y-TZP Lava Esthetic Fluorescent Zirconia crown or an IPS e.max CAD lithium disilicate crown was randomly provided for 24 participants (n=12). The contralateral first molar and opposite teeth were the natural enamel controls. The crowns were fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology and then polished. The data were gathered every 6 months at recall appointments with an intraoral scanner and a polyvinyl siloxane impression. A 3-dimensional (3D) comparative software program was used to measure the maximum vertical and volume loss on opposing enamel, as well as on the enamel control on the opposite side of the mouth. The surface of epoxy resin replicas was analyzed using a scanning electron microscope. The surface roughness of the cusp replica was measured with a 3D laser microscope. The crown's antagonist enamel and natural enamel wear were compared using a 2-way repeated measure ANOVA (α=.05). RESULTS No significant difference was found in the average volume loss between the crown's antagonist enamel (ZTE 0.042 ±0.005 mm3, LTE 0.048 ±0.006 mm3) and the enamel control (ZCE 0.046 ±0.004 mm3, LCE 0.050 ±0.005 mm3) (P>.05). No significant difference was found in surface roughness between the crown's antagonist enamel (antagonist enamel of zirconia group [ZTE] 0.7 ±0.3 µm, antagonist enamel of lithium disilicate group [LTE] 0.6 ±0.3 µm) and the enamel control (enamel control of zirconia group [ZCE] 0.7 ±0.3 µm, enamel control of lithium disilicate group [LCE] 0.5 ±0.2 µm) in both zirconia and lithium disilicate groups (P>.05). Also, no correlation was found between the amount of wear and the roughness of the surface. The wear patterns observed on the opposing enamel surfaces of the monolithic zirconia and lithium disilicate materials were found to be similar to those seen on natural enamel. CONCLUSIONS A 2-year clinical investigation found that polished lithium disilicate and 5Y-TZP crowns did not affect enamel wear more than enamel against enamel, contrary to laboratory studies. Another finding revealed that surface roughness did not significantly affect wear.
Collapse
Affiliation(s)
- Piyarat Woraganjanaboon
- Doctoral student, Dental Biomaterials Science, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Pisol Senawongse
- Associate Professor, Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Chuchai Anunmana
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand.
| |
Collapse
|
2
|
Shah N, Nerkar H, Badwaik P, Ahuja B, Malu R, Bhanushali N. An evaluation of antagonist enamel wear opposing full-coverage zirconia crowns versus other ceramics full-coverage crowns and natural enamel - An umbrella review. J Indian Prosthodont Soc 2024; 24:217-224. [PMID: 38946503 PMCID: PMC11321487 DOI: 10.4103/jips.jips_32_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 03/29/2024] [Accepted: 04/09/2024] [Indexed: 07/02/2024] Open
Abstract
AIM The aim of this umbrella review was to systematically review the systematic reviews on antagonist enamel wear opposing zirconia crowns compared to other ceramics and natural enamel. SETTINGS AND DESIGN This was an umbrella review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. MATERIALS AND METHODS An electronic search of PubMed, Cochrane Central, EBSCOhost, and Google Scholar search engines for articles published from January 1, 2013, to January 1, 2023, was conducted using keywords "enamel wear," "zirconia," "feldspathic," "dental ceramics," and "Y-TZP" to identify systematic reviews on antagonist enamel wear opposing zirconia crowns compared to other ceramics and natural enamel. STATISTICAL ANALYSIS USED Qualitative analysis. RESULTS A total of 86 articles were obtained through electronic search, of which four articles were selected after abstract screening that met the inclusion criteria for evaluating antagonist enamel wear. As compared to feldspathic groups, zirconia had substantially less antagonist wear, while surface polishing exhibited less enamel wear than glazing. Because of the heterogeneity in study design, measurement methods, and outcome variables, a meta-analysis was not possible. CONCLUSIONS Over time, the opposing enamel wear caused by polished monolithic zirconia will be either equal to or less than that of natural enamel wear. Polished monolithic zirconia also maintains lower values of enamel wear compared to metal ceramics, feldspathic porcelains, and lithium disilicate.
Collapse
Affiliation(s)
- Naisargi Shah
- Department of Prosthodontics and Crown and Bridge and Terna Dental College, Navi Mumbai, Maharashtra, India
| | - Harshada Nerkar
- Department of Prosthodontics and Crown and Bridge and Terna Dental College, Navi Mumbai, Maharashtra, India
| | - Praveen Badwaik
- Department of Prosthodontics and Crown and Bridge and Terna Dental College, Navi Mumbai, Maharashtra, India
| | - Bhavna Ahuja
- Department of Prosthodontics and Crown and Bridge and Terna Dental College, Navi Mumbai, Maharashtra, India
| | - Rahul Malu
- Department of Prosthodontics and Crown and Bridge and Terna Dental College, Navi Mumbai, Maharashtra, India
| | - Nikhil Bhanushali
- Department of Public Health Dentistry, Terna Dental College, Navi Mumbai, Maharashtra, India
| |
Collapse
|
3
|
Sagawa M, Namura Y, Uchida Y, Miyama W, Nishimura S, Yoneyama T, Takamizawa T, Motoyoshi M. Changes in enamel hardness, wear resistance, surface texture, and surface crystal structure with glass ionomer cement containing BioUnion fillers. Dent Mater J 2024; 43:247-254. [PMID: 38382940 DOI: 10.4012/dmj.2023-180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
This study investigated the potential of BioUnion filler containing glass ionomer cement (GIC) to enhance the properties of enamel surrounding restorations, with a specific focus on the effect on hardness. The hardness of the bovine enamel immersed in the cement was measured using Vickers hardness numbers. Following sliding and impact wear simulations, the enamel facets were examined using confocal-laser-scanning microscopy and scanning-electron microscopy. Surface properties were further analyzed using energy-dispersive X-ray spectroscopy and X-ray diffraction (XRD). A significant increase in Vickers hardness numbers was observed in the BioUnion filler GIC after 2 days. Furthermore, the mean depth of enamel facets treated with BioUnion filler GIC was significantly less than that of untreated facets. Characteristic XRD peaks indicating the presence of hydroxyapatite were also observed. Our findings imply that GIC with BioUnion fillers enhances the mechanical properties of the tooth surface adjacent to the cement.
Collapse
Affiliation(s)
- Misuzu Sagawa
- Department of Orthodontics, Nihon University School of Dentistry
| | - Yasuhiro Namura
- Department of Orthodontics, Nihon University School of Dentistry
- Division of Clinical Research, Dental Research Center, Nihon University School of Dentistry
| | - Yasuki Uchida
- Department of Orthodontics, Nihon University School of Dentistry
- Division of Clinical Research, Dental Research Center, Nihon University School of Dentistry
| | - Wakako Miyama
- Department of Orthodontics, Nihon University School of Dentistry
- Division of Clinical Research, Dental Research Center, Nihon University School of Dentistry
| | - Shirabe Nishimura
- Department of Orthodontics, Nihon University School of Dentistry
- Department of Oral Structural and Functional Biology, Nihon University Graduate School of Dentistry
| | - Toshihiro Yoneyama
- Department of Orthodontics, Nihon University School of Dentistry
- Department of Oral Structural and Functional Biology, Nihon University Graduate School of Dentistry
| | - Toshiki Takamizawa
- Department of Operative Dentistry, Nihon University School of Dentistry
- Division of Biomaterials Science, Dental Research Center, Nihon University School of Dentistry
| | - Mitsuru Motoyoshi
- Department of Orthodontics, Nihon University School of Dentistry
- Division of Clinical Research, Dental Research Center, Nihon University School of Dentistry
| |
Collapse
|
4
|
Woraganjanaboon P, Anunmana C. 3D quantitative analysis and SEM qualitative analysis of natural antagonist enamel opposing CAD-CAM monolithic zirconia or lithium disilicate tooth-supported crowns versus enamel opposing natural enamel. J Adv Prosthodont 2024; 16:12-24. [PMID: 38455676 PMCID: PMC10917629 DOI: 10.4047/jap.2024.16.1.12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 01/16/2024] [Accepted: 02/13/2024] [Indexed: 03/09/2024] Open
Abstract
PURPOSE This study aimed to evaluate the maximum vertical wear, volume wear, and surface characteristic of antagonist enamel, opposing monolithic zirconia or lithium disilicate crowns. MATERIALS AND METHODS The study comprised 24 participants (n = 12), who were randomly allocated to receive either a 5 mol% Y-TZP or a lithium disilicate crown in positions which would oppose the natural first molar tooth. The contralateral first molar along with its antagonist was considered as the enamel opposing natural enamel control. Data collection was performed using an intraoral scanner and polyvinylsiloxane impression. The means of the maximum vertical loss and the volume loss at the occlusal contact areas of the crowns and the various natural antagonists were measured by 3D comparison software. A scanning electron microscope was subsequently used to assess the wear characteristics. Results The one-year results from 22 participants (n = 11) indicated no significant differences when comparing the zirconia crown's antagonist enamel (40.28 ± 9.11 µm, 0.04 ± 0.02 mm3) and the natural enamel wear (38.91 ± 7.09 µm, 0.04 ± 0.02 mm3) (P > .05). Also, there is no significant differences between lithium disilicate crown's antagonist enamel (47.81 ± 9.41 µm, 0.04 ± 0.02 mm3) and the natural enamel wear (39.11 ± 7.90 µm, 0.04 ± 0.02 mm3) (P > .05). Conclusion While some studies suggested that monolithic zirconia caused less wear on opposing enamel than lithium disilicate, this study found similar wear levels to enamel for both materials compared to natural teeth.
Collapse
Affiliation(s)
- Piyarat Woraganjanaboon
- Doctor of Philosophy Program in Dental Biomaterials Science, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Chuchai Anunmana
- Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| |
Collapse
|
5
|
Naffah N, Ounsi H, Ozcan M, Salameh Z. Evaluation of the Color Stability of Three Resin-Ceramic Materials Using a Spectrophotometer and a Digital Photography Software. Contemp Clin Dent 2024; 15:44-50. [PMID: 38707666 PMCID: PMC11068248 DOI: 10.4103/ccd.ccd_656_18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 11/15/2018] [Accepted: 11/26/2018] [Indexed: 05/07/2024] Open
Abstract
Background Computer-aided design/computer-aided manufacturing (CAD/CAM) resin ceramics allow easier milling than glass ceramics but are suspected to be more stainable. Although Photoshop® is widely used for picture analysis, its potential for shade selection has not been properly assessed. Aim Purpose primary: To evaluate the color stability of three CAD/CAM resin ceramics and Lithium Disilicate. Secondary: to compare the color evaluation between a spectrophotometer (Vita Easyshade compact) and Photoshop software. Materials and Methods Three CAD/CAM resin ceramic materials (n = 10) and a fourth group of lithium disilicate were used. Half of each group were thermocycled (5°C and 55°C; 3000 cycles). All samples were immersed in colored beverages (coffee, tea and red wine) for 30 days. Values were obtained by spectrophotometry and photographs analyzed using Photoshop software. The parameters measured were CIEL*a*b, and the color difference (ΔE) was analyzed. A mixed model test was used to compare the results through time and materials (α = 0.05). The comparison between the spectrophotometer and Photoshop results was performed using the bivariate Pearson's correlation test. Results Lithium disilicate glass ceramic exhibited less color change (ΔE = 14) than resin ceramics (15.7 < ΔE < 18.7). The least change was noted with GC Cerasmart (ΔE = 15.7) followed by Vita Enamic (ΔE = 17*) and Brilliant Crios (ΔE = 18.7*). Spectrophotometer and Photoshop values showed low correlations. Conclusions Resin ceramics may suffer from color change in clinical use. Photoshop is technique sensitive; pictures are easily affected by the light conditions and camera settings.
Collapse
Affiliation(s)
- Nicolas Naffah
- Department of Prosthodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| | - Hani Ounsi
- Department of Endodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
- Faculty of Dental Medicine, Siena University, Siena, Italy
| | - Mutlu Ozcan
- University of Zurich, Division of Dental Biomaterials, Clinic of Reconstructive Dentistry, Center of Dental Medicine, Zurich, Switzerland
| | - Ziad Salameh
- Department of Prosthodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| |
Collapse
|
6
|
Kosewski P, De Angelis F, Sorrentino E, Mielczarek A, Buonvivere M, D’Arcangelo C. Effect of the Abutment Rigidity on the Wear Resistance of a Lithium Disilicate Glass Ceramic: An In Vitro Study. J Funct Biomater 2023; 14:395. [PMID: 37623640 PMCID: PMC10455685 DOI: 10.3390/jfb14080395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 07/20/2023] [Accepted: 07/21/2023] [Indexed: 08/26/2023] Open
Abstract
Lithium disilicate (LDS) glass ceramics are among the most common biomaterials in conservative dentistry and prosthodontics, and their wear behavior is of paramount clinical interest. An innovative in vitro model is presented, which employs CAD/CAM technology to simulate the periodontal ligament and alveolar bone. The model aims to evaluate the effect of the abutment rigidity on the wear resistance of the LDS glass ceramic. Two experimental groups (LDS restorations supported by dental implants, named LDS-on-Implant, or by hybrid ceramic tooth replicas with artificial periodontal ligament, named LDS-on-Tooth-Replica) and a control group (LDS-Cylinders) were compared. Fifteen samples (n = 15) were fabricated for each group and subjected to testing, with LDS antagonistic cusps opposing them over 120,000 cycles using a dual axis chewing simulator. Wear resistance was analyzed by measuring the vertical wear depth (mm) and the volume loss (mm3) on each LDS sample, as well as the linear antagonist wear (mm) on LDS cusps. Mean values were calculated for LDS-Cylinders (0.186 mm, 0.322 mm3, 0.220 mm, respectively), LDS-on-Implant (0.128 mm, 0.166 mm3, 0.199 mm, respectively), and LDS-on-Tooth-Replica (0.098 mm, 0.107 mm3, 0.172 mm, respectively) and compared using one-way-ANOVA and Tukey's tests. The level of significance was set at 0.05 in all tests. Wear facets were inspected under a scanning electron microscope. Data analysis revealed that abutment rigidity was able to significantly affect the wear pattern of LDS, which seems to be more intense on rigid implant-abutment supports compared to resilient teeth replicas with artificial periodontal ligament.
Collapse
Affiliation(s)
| | - Francesco De Angelis
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Science, School of Dentistry, “G. D’Annunzio” University of Chieti, 66100 Chieti, Italy; (M.B.); (C.D.)
| | - Edoardo Sorrentino
- Department of Innovative Technologies in Medicine & Dentistry, “G. D’Annunzio” University of Chieti, 66100 Chieti, Italy;
| | - Agnieszka Mielczarek
- Department of Conservative Dentistry, Medical University of Warsaw, 02091 Warsaw, Poland;
| | - Matteo Buonvivere
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Science, School of Dentistry, “G. D’Annunzio” University of Chieti, 66100 Chieti, Italy; (M.B.); (C.D.)
| | - Camillo D’Arcangelo
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Science, School of Dentistry, “G. D’Annunzio” University of Chieti, 66100 Chieti, Italy; (M.B.); (C.D.)
| |
Collapse
|
7
|
Tokunaga J, Ikeda H, Nagamatsu Y, Awano S, Shimizu H. Wear of Polymer-Infiltrated Ceramic Network Materials against Enamel. MATERIALS 2022; 15:ma15072435. [PMID: 35407767 PMCID: PMC8999962 DOI: 10.3390/ma15072435] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 03/16/2022] [Accepted: 03/23/2022] [Indexed: 12/25/2022]
Abstract
Polymer-infiltrated ceramic network materials (PICNs) have high mechanical compatibility with human enamel. However, the wear properties of PICN against natural human enamel have not yet been clarified. We investigated the in vitro two-body wear behaviors of PICNs and an enamel antagonist. Two PICNs were used: Experimental PICN (EXP) prepared via the infiltration of methacrylate-based resin into the porous silica ceramic network and commercial Vita Enamic (ENA). Two commercial dental ceramics, lithium disilicate glass (LDS) and zirconia (ZIR), were also characterized, and their wear performance was compared to PICNs. The samples were subjected to Vickers hardness tests and two-body wear tests that involve the samples being cyclically impacted by enamel antagonists underwater at 37 °C. The results reveal that the Vickers hardness of EXP (301 ± 36) was closest to that of enamel (317 ± 17). The volumetric wear losses of EXP and ENA were similar to those of LDS but higher than that of zirconia. The volumetric wear loss of the enamel antagonist impacted against EXP was moderate among the examined samples. These results suggest that EXP has wear behavior similar to that of enamel. Therefore, PICNs are mechanically comparable to enamel in terms of hardness and wear and are excellent tooth-restoration materials.
Collapse
Affiliation(s)
- Jumpei Tokunaga
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan; (J.T.); (Y.N.); (H.S.)
- Division of Clinical Education Development and Research, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan;
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan; (J.T.); (Y.N.); (H.S.)
- Correspondence:
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan; (J.T.); (Y.N.); (H.S.)
| | - Shuji Awano
- Division of Clinical Education Development and Research, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan;
| | - Hiroshi Shimizu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka 803-8580, Japan; (J.T.); (Y.N.); (H.S.)
| |
Collapse
|
8
|
Yadav R, Meena A, Patnaik A. Biomaterials for dental composite applications: A comprehensive review of physical, chemical, mechanical, thermal, tribological, and biological properties. POLYM ADVAN TECHNOL 2022. [DOI: 10.1002/pat.5648] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Ramkumar Yadav
- Department of Mechanical Engineering Malaviya National Institute of Technology Jaipur Rajasthan India
| | - Anoj Meena
- Department of Mechanical Engineering Malaviya National Institute of Technology Jaipur Rajasthan India
| | - Amar Patnaik
- Department of Mechanical Engineering Malaviya National Institute of Technology Jaipur Rajasthan India
| |
Collapse
|
9
|
Ghaffari T, Rad F, Goftari A, Pashazadeh F, Ataei K. Natural teeth wear opposite to glazed and polished ceramic crowns: A systematic review. Dent Res J (Isfahan) 2022. [DOI: 10.4103/1735-3327.363567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
|
10
|
Sellan PLB, Campaner LM, Tribst JPM, Dal Piva AMDO, de Andrade GS, Borges ALS, Bresciani E, Lanzotti A, Ausiello P. Functional or Nonfunctional Cusps Preservation for Molars Restored with Indirect Composite or Glass-Ceramic Onlays: 3D FEA Study. Polymers (Basel) 2021; 13:polym13213831. [PMID: 34771387 PMCID: PMC8587095 DOI: 10.3390/polym13213831] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 11/04/2021] [Accepted: 11/04/2021] [Indexed: 02/01/2023] Open
Abstract
Evidence regarding the effect of the onlay preparation design for different CAD/CAM restorative materials considering the preservation of cusps is lacking. Molars were 3D-modeled in four preparation designs for onlay restoration: traditional design with functional cusp coverage (TFC), non-retentive design with functional cusp coverage (NFC), traditional design with non-functional cusp coverage (TNFC) and non-retentive design with non-functional cusp coverage (NNFC). The restorations were simulated with two CAD/CAM restorative materials: LD—lithium disilicate (IPS e.max CAD) and RC—resin composite (GrandioBloc). A 100 N axial load was applied to the occlusal surface, simulating the centric contact point. Von Mises (VM) and maximum principal (Pmax) stress were evaluated for restorations, cement layer and dental substrate. The non-retentive preparation design reduced the stress concentration in the tooth structure in comparison to the conventional retentive design. For LD onlays, the stress distribution on the restoration intaglio surface showed that the preparation design, as well as the prepared cusp, influenced the stress magnitude. The non-retentive preparation design provided better load distribution in both restorative materials and more advantageous for molar structure. The resin composite restoration on thenon-functional cusp is recommended when the functional cusp is preserved in order to associate conservative dentistry and low-stress magnitude.
Collapse
Affiliation(s)
- Pablo Lenin Benitez Sellan
- School of Dentistry, Universidad Espíritu Santo, Samborondón 092301, Ecuador;
- Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, São Paulo 12220-690, Brazil; (L.M.C.); (A.L.S.B.); (E.B.)
| | - Larissa Mendes Campaner
- Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, São Paulo 12220-690, Brazil; (L.M.C.); (A.L.S.B.); (E.B.)
| | - João Paulo Mendes Tribst
- Department of Dental Materials, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, 1081 LA Amsterdam, The Netherlands; (J.P.M.T.); (A.M.d.O.D.P.)
| | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, 1081 LA Amsterdam, The Netherlands; (J.P.M.T.); (A.M.d.O.D.P.)
| | - Guilherme Schmitt de Andrade
- Department of Dentistry, Center for Biological and Health Sciences, Western Paraná State University (Unioeste), Cascavel 85819-110, Brazil;
| | - Alexandre Luiz Souto Borges
- Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, São Paulo 12220-690, Brazil; (L.M.C.); (A.L.S.B.); (E.B.)
| | - Eduardo Bresciani
- Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, São Paulo 12220-690, Brazil; (L.M.C.); (A.L.S.B.); (E.B.)
| | - Antonio Lanzotti
- Fraunhofer JL IDEAS, Department of Industrial Engineering, University of Naples Federico II, 80125 Naples, Italy;
| | - Pietro Ausiello
- School of Dentistry, University of Naples Federico II, 80131 Naples, Italy
- Correspondence:
| |
Collapse
|
11
|
Namura Y, Uchida Y, Inaba M, Kaetsu R, Utsu A, Takamizawa T, Miyazaki M, Motoyoshi M. Influence of masticating cycles and chewing patterns on inadvertent enamel wear caused by zirconia brackets. Eur J Oral Sci 2021; 130:e12831. [PMID: 34674322 DOI: 10.1111/eos.12831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 09/07/2021] [Indexed: 12/01/2022]
Abstract
Little information is available about enamel wear caused by zirconia brackets, an inadvertent side effect of orthodontic treatment. The purpose of this study was to examine potential enamel damage induced by contact with zirconia brackets. Sliding and impact wear simulations were performed using bovine enamel specimens positioned at a 25° slant to a zirconium ball to determine wear behaviour. Different chewing patterns, tapping and grinding, were simulated. Specimens were profiled using confocal laser scanning microscopy, and the mean maximum depth and surface roughness were measured. Scanning electron microscopy was also performed. The mean maximum depth of wear values differed according to the number of mastication cycles, with a higher number of cycles producing higher depths of wear. The facet wear depth was significantly greater with the tapping pattern than with the grinding pattern. Scanning electron microscopic observation of the wear facets revealed that surface textures at the edges were rougher than those at the centre of all facets. The results of this study indicated that enamel wear was induced by contact with zirconia brackets during the early period of mastication, and that the patterns and number of cycles of mastication affected the wear progression of enamel.
Collapse
Affiliation(s)
- Yasuhiro Namura
- Department of Orthodontics, Nihon University School of Dentistry, Tokyo, Japan.,Division of Clinical Research, Dental Research Centre, Nihon University School of Dentistry, Tokyo, Japan
| | - Yasuki Uchida
- Department of Orthodontics, Nihon University School of Dentistry, Tokyo, Japan.,Division of Clinical Research, Dental Research Centre, Nihon University School of Dentistry, Tokyo, Japan
| | - Mizuki Inaba
- Department of Orthodontics, Nihon University School of Dentistry, Tokyo, Japan.,Division of Clinical Research, Dental Research Centre, Nihon University School of Dentistry, Tokyo, Japan
| | - Ryo Kaetsu
- Department of Oral Structural and Functional Biology, Nihon University Graduate School of Dentistry, Tokyo, Japan
| | - Akihisa Utsu
- Department of Oral Structural and Functional Biology, Nihon University Graduate School of Dentistry, Tokyo, Japan
| | - Toshiki Takamizawa
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan.,Division of Biomaterials Science, Dental Research Centre, Nihon University School of Dentistry, Tokyo, Japan
| | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan.,Division of Biomaterials Science, Dental Research Centre, Nihon University School of Dentistry, Tokyo, Japan
| | - Mitsuru Motoyoshi
- Department of Orthodontics, Nihon University School of Dentistry, Tokyo, Japan.,Division of Clinical Research, Dental Research Centre, Nihon University School of Dentistry, Tokyo, Japan
| |
Collapse
|
12
|
Ozkir SE, Bicer M, Deste G, Karakus E, Yilmaz B. Wear of monolithic zirconia against different CAD-CAM and indirect restorative materials. J Prosthet Dent 2021; 128:505-511. [PMID: 34059295 DOI: 10.1016/j.prosdent.2021.03.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 03/23/2021] [Accepted: 03/24/2021] [Indexed: 11/30/2022]
Abstract
STATEMENT OF PROBLEM The wear of monolithic zirconia against enamel has been widely studied, but how zirconia affects different opposing restorative materials is not clear. PURPOSE The purpose of this in vitro study was to investigate the depth of wear and volumetric loss of different restorative materials opposed by monolithic zirconia. MATERIAL AND METHODS Sixty-six Ø10×3-mm specimens (n=11) were fabricated from monolithic zirconia, zirconia reinforced ceramic, lithium disilicate ceramic, feldspathic ceramic, ORMOCER, and ceramic optimized polymer. A 2-body pin-on-disk wear test was performed by using monolithic zirconia pins. The specimens were scanned with a noncontact profilometer after the tests. The scan parameters were a frame size area of 1.5×1.5 mm, frequency of 400 Hz, and scan sensitivity of 2 μm. After the evaluation of depth and volume loss, the specimens were analyzed with a scanning electron microscope. The Kruskal-Wallis test was used to analyze the differences in wear values across the specimen groups, and pairwise comparison tests were performed with a post hoc test (α=.05). RESULTS Maximum depth of wear was 257.55 ±18.88 μm for lithium disilicate ceramic, 295.36 ±14.46 μm for zirconia reinforced ceramic, 421.82 ±214.49 μm for ORMOCER, 333.73 ±79.09 μm for ceramic optimized polymer, 146.27 ±22.86 μm for feldspathic ceramic, and 41.55 ±5.04 μm for monolithic zirconia. The depth of wear was not significantly different among lithium disilicate, zirconia-reinforced ceramic, ORMOCER, and ceramic optimized polymer (P<.05). However, the depth of wear of monolithic zirconia and feldspathic ceramic was less than that of other materials (P<.001). Volume loss of lithium disilicate was 1.68 ±0.25 mm3, 1.08 ±0.35 mm3 for zirconia reinforced ceramic, 4.29 ±2.91 mm3 for ORMOCER, 2.46 ±0.63 mm3 for resin ceramic, 1.07 ±0.09 mm3 for feldspathic ceramic, and 0.19 ±0.02 mm3 for monolithic zirconia. Feldspathic ceramic and monolithic zirconia had significantly less volume loss than the other groups (P<.001), and the difference between them for volume loss was statistically insignificant (P>.05). CONCLUSIONS The tested ceramic-based materials had favorable wear resistance compared with the tested composite resin-based ones. However, the ceramics tended to crack formation than the composite resins.
Collapse
Affiliation(s)
- Serhat Emre Ozkir
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskişehir, Turkey.
| | - Mehmet Bicer
- Research Assistant, Department of Prosthodontics, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey
| | - Gonca Deste
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Uludag University, Bursa, Turkey
| | - Elif Karakus
- Research Assistant, Department of Prosthodontics, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| |
Collapse
|
13
|
The effect of different storage media on the monomer elution and hardness of CAD/CAM composite blocks. Dent Mater 2021; 37:1202-1213. [PMID: 33962792 DOI: 10.1016/j.dental.2021.04.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 03/29/2021] [Accepted: 04/24/2021] [Indexed: 11/20/2022]
Abstract
OBJECTIVE This study aimed to assess the effect of different storage media on the hardness and monomer elution of CAD/CAM composite blocks. METHODS Five resin-composite blocks (RCB), one polymer-infiltrated ceramic network (PICN) block (Enamic (EN)), one ceramic-filled poly ether ether ketone (PEEK) block (Dentokeep (DK)), and one feldspathic ceramic block. Microhardness was measured using a Vickers indenter tester (FM-700, Future Tech Corp., Japan). In addition 4 conventional resin-composites were investigated for monomer elution using high performance liquid chromatography (HPLC) after storage in different media for 3 months. The data were analysed by three-way ANOVA, two-way ANOVA, one-way ANOVA, Tukey's post hoc test and the independent t-test (α=0.05 for all tests). RESULTS The specimens stored in the water had a hardness reduction ranging from 0.9% to 24.4%. In artificial saliva, the specimens had a hardness reduction ranging from 2.8% to 23.2%. The hardness reduction percentage in 75% Ethanol/Water (E/W) ranged between 3.8% and 35.3%. All materials, except GR (resin-composite block) and DK (Polyetheretherketone (PEEK)), showed a variable extent of monomer elution into 75% E/W with significantly higher amounts eluted from conventional composites. GRA and GND (conventional resin-composites) eluted TEGDMA in artificial saliva and GRA eluted TEGDMA in water. SIGNIFICANCE The hardness of CAD/CAM composite blocks was affected by different storage media, and they were not as stable as ceramic, with PICN exhibited superior hardness stability to all of the resin-composite blocks in all the storage media and was comparable to ceramic block. The hardness reduction percentage of the CAD/CAM composite blocks was influenced by the filler loading and resin-matrix composition.Minimal or no monomer elution from CAD/CAM blocks was detected.
Collapse
|
14
|
Branco AC, Colaço R, Figueiredo-Pina CG, Serro AP. A State-of-the-Art Review on the Wear of the Occlusal Surfaces of Natural Teeth and Prosthetic Crowns. MATERIALS 2020; 13:ma13163525. [PMID: 32785120 PMCID: PMC7476047 DOI: 10.3390/ma13163525] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 07/31/2020] [Accepted: 08/06/2020] [Indexed: 11/16/2022]
Abstract
This review focuses on the wear mechanisms of natural and restorative dental materials, presenting a comprehensive description and analysis of the works published in the last two decades on the wear at the interface of occlusal surfaces. Different groups of tribological pairs were considered: tooth-tooth, tooth-restorative material (tooth-ceramic, tooth-resin-based-materials, and tooth-metal), and restorative-restorative materials. The lack of standardization of the wear tests impairs the direct comparison of the obtained results. However, it was possible to infer about the main wear mechanisms observed on the different classes of dental materials. Concerning ceramics, their toughness and surface finishing determines the wear of antagonist tooth. Abrasion revealed to be the main wear mechanisms at occlusal interface. In the case of resin-based composites, the cohesion of the organic matrix and the nature, shape, and amount of filler particles greatly influences the dental wear. The protruding and detachment of the filler particles are the main causes of abrasion of antagonist enamel. Metallic materials induce lower wear on antagonist enamel than the other classes of materials, because of their low hardness and high ductility. Most of the studies revealed plastic deformation and adhesive wear as the main wear mechanisms. Overall, more research in this area is needed for a better understanding of the mechanisms involved at the occlusal surfaces wear. This would be essential for the development of more suitable restoration materials.
Collapse
Affiliation(s)
- Ana Catarina Branco
- Centro de Química Estrutural (CQE), Instituto Superior Técnico, University of Lisbon, 1049-001 Lisbon, Portugal; (A.C.B.); (A.P.S.)
- Centro de Desenvolvimento de Produto e Transferência de Tecnologia (CDP2T), Department of Mechanical Engineering, Instituto Politécnico de Setúbal, 2910-761 Setúbal, Portugal
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz, 2829-511 Caparica, Portugal
| | - Rogério Colaço
- Instituto de Engenharia Mecânica (IDMEC), Department of Mechanical Engineering, Instituto Superior Técnico, University of Lisbon, 1049-001 Lisbon, Portugal;
| | - Célio Gabriel Figueiredo-Pina
- Centro de Desenvolvimento de Produto e Transferência de Tecnologia (CDP2T), Department of Mechanical Engineering, Instituto Politécnico de Setúbal, 2910-761 Setúbal, Portugal
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz, 2829-511 Caparica, Portugal
- Centro de Física e Engenharia de Materiais Avançados (CeFEMA), Instituto Superior Técnico, University of Lisbon, 1049-001 Lisbon, Portugal
- Correspondence:
| | - Ana Paula Serro
- Centro de Química Estrutural (CQE), Instituto Superior Técnico, University of Lisbon, 1049-001 Lisbon, Portugal; (A.C.B.); (A.P.S.)
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz, 2829-511 Caparica, Portugal
| |
Collapse
|
15
|
Rosentritt M, Schumann F, Krifka S, Preis V. Influence of zirconia and lithium disilicate tooth- or implant-supported crowns on wear of antagonistic and adjacent teeth. J Adv Prosthodont 2020; 12:1-8. [PMID: 32128080 PMCID: PMC7040450 DOI: 10.4047/jap.2020.12.1.1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Revised: 01/22/2020] [Accepted: 01/23/2020] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To investigate the influence of crown material (lithium-disilicate, 3Y-TZP zirconia) and abutment type (rigid implant, resin tooth with artificial periodontium) on wear performance of their antagonist teeth and adjacent teeth. MATERIALS AND METHODS A mandibular left first molar (#36) with adjacent human teeth (mandibular left second premolar: #35, mandibular left second molar: #37) and antagonistic human teeth (maxillary left second premolar: #25, maxillary left first molar: #26, maxillary left second molar: #27) was prepared simulating a section of the jaw. Samples were made with extracted human molars (Reference), crowned implants (Implant), or crowned resin tooth analogues (Tooth). Crowns (tooth #36; n = 16/material) were milled from lithium-disilicate (Li, IPS e.max CAD) or 3Y-TZP zirconia (Zr, IPS e.max ZirCAD, both Ivoclar Vivadent). Thermal cycling and mechanical loading (TCML) in the chewing simulator were applied simulating 15 years of clinical service. Wear traces were analyzed (frequency [n], depth [µm]) and evaluated using scanning electron pictures. Wear results were compared by one-way-ANOVA and post-hoc-Bonferroni (α = 0.05). RESULTS After TCML, no visible wear traces were found on Zr. Li showed more wear traces (n = 30–31) than the reference (n = 21). Antagonistic teeth #26 showed more wear traces in contact to both ceramics (n = 27–29) than to the reference (n = 21). Strong wear traces (> 350 µm) on antagonists and their adjacent teeth were found only in crowned groups. Abutment type influenced number and depth of wear facets on the antagonistic and adjacent teeth. CONCLUSION The clinically relevant model with human antagonistic and adjacent teeth allowed for a limited comparison of the wear situation. The total number of wear traces and strong wear on crowns, antagonistic and adjacent teeth were influenced by crown material.
Collapse
Affiliation(s)
- Martin Rosentritt
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, Regensburg, Germany
| | - Frederik Schumann
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, Regensburg, Germany
| | - Stephanie Krifka
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, Regensburg, Germany
| | - Verena Preis
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|
16
|
Nazirkar GS, Patil SV, Shelke PP, Mahagaonkar P. Comparative evaluation of natural enamel wear against polished yitrium tetragonal zirconia and polished lithium disilicate - An in vivo study. J Indian Prosthodont Soc 2020; 20:83-89. [PMID: 32089603 PMCID: PMC7008616 DOI: 10.4103/jips.jips_218_19] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Revised: 10/22/2019] [Accepted: 12/27/2019] [Indexed: 11/13/2022] Open
Abstract
Aim: The aim of this study is to compare wear of the natural teeth against polished yttrium tetragonal zirconia and polished lithium disilicate crowns. Study Setting and Design: Experimental type of study. Materials and Methods: Polished yttrium tetragonal zirconia and polished lithium disilicate crowns were fabricated and given to 15 patients each (n=15). Crowns were fabricated opposing natural tooth. Patients were recalled after 1year and impression were recorded with opposing arch and baseline and final cast were scanned and superimposed using 3 D scanner. Statistical Analysis Used: Data collected by experiments were computerized and analyzed using the Statistical Package for Social Sciences (SPSS) version 16.0. The normality of the data was checked using the Kolmogorov-Smirnov test and Shapiro-Wilk tests. The data were normally distributed. Statistical analysis was done by using tools of descriptive statistics such as Mean, and Standard Deviation for representing quantitative data (enamel wear measured in μm) Parametric tests: Student t-test for intergroup comparison was done. Results: No statistical difference were found between wear of opposing enamel for polished yttrium tetragonal and polished lithium disiliacte crowns [p=0.446]. Conclusion: Within the limitations of the study, it can be concluded that polished lithium disilicate showed better clinical outcome than polished yttrium tetragonal zirconia, though the evaluated data was statistically non significant.
Collapse
Affiliation(s)
- Girish S Nazirkar
- Department of Prosthodontics and Crown & Bridge, SMBT Dental College and Hospital, Sangamner, Ahmednagar, Maharashtra, India
| | - Swati Vijay Patil
- Department of Prosthodontics and Crown & Bridge, SMBT Dental College and Hospital, Sangamner, Ahmednagar, Maharashtra, India
| | - Priyanka P Shelke
- Department of Prosthodontics and Crown & Bridge, SMBT Dental College and Hospital, Sangamner, Ahmednagar, Maharashtra, India
| | - Preetam Mahagaonkar
- Department of Prosthodontics and Crown & Bridge, SMBT Dental College and Hospital, Sangamner, Ahmednagar, Maharashtra, India
| |
Collapse
|
17
|
Aydın N, Karaoğlanoğlu S, Oktay EA, Kılıçarslan MA. Investigating the color changes on resin‐based CAD/CAM Blocks. J ESTHET RESTOR DENT 2019; 32:251-256. [DOI: 10.1111/jerd.12561] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Revised: 10/31/2019] [Accepted: 12/11/2019] [Indexed: 01/01/2023]
Affiliation(s)
- Numan Aydın
- Gulhane Faculty of Dentistry, Department of Restorative Dental TreatmentUniversity of Health Sciences Ankara Turkey
| | - Serpil Karaoğlanoğlu
- Gulhane Faculty of Dentistry, Department of Restorative Dental TreatmentUniversity of Health Sciences Ankara Turkey
| | - Elif A. Oktay
- Gulhane Faculty of Dentistry, Department of Restorative Dental TreatmentUniversity of Health Sciences Ankara Turkey
| | | |
Collapse
|
18
|
Zarone F, Di Mauro MI, Ausiello P, Ruggiero G, Sorrentino R. Current status on lithium disilicate and zirconia: a narrative review. BMC Oral Health 2019; 19:134. [PMID: 31272441 PMCID: PMC6610968 DOI: 10.1186/s12903-019-0838-x] [Citation(s) in RCA: 191] [Impact Index Per Article: 31.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 06/27/2019] [Indexed: 01/28/2023] Open
Abstract
Background The introduction of the new generation of particle-filled and high strength ceramics, hybrid composites and technopolymers in the last decade has offered an extensive palette of dental materials broadening the clinical indications in fixed prosthodontics, in the light of minimally invasive dentistry dictates. Moreover, last years have seen a dramatic increase in the patients’ demand for non-metallic materials, sometimes induced by metal-phobia or alleged allergies. Therefore, the attention of scientific research has been progressively focusing on such materials, particularly on lithium disilicate and zirconia, in order to shed light on properties, indications and limitations of the new protagonists of the prosthetic scene. Methods This article is aimed at providing a narrative review regarding the state-of-the-art in the field of these popular ceramic materials, as to their physical-chemical, mechanical and optical properties, as well as to the proper dental applications, by means of scientific literature analysis and with reference to the authors’ clinical experience. Results A huge amount of data, sometimes conflicting, is available today. Both in vitro and in vivo studies pointed out the outstanding peculiarities of lithium disilicate and zirconia: unparalleled optical and esthetic properties, together with high biocompatibility, high mechanical resistance, reduced thickness and favorable wear behavior have been increasingly orientating the clinicians’ choice toward such ceramics. Conclusions The noticeable properties and versatility make lithium disilicate and zirconia materials of choice for modern prosthetic dentistry, requiring high esthetic and mechanical performances combined with a minimal invasive approach, so that the utilization of such metal-free ceramics has become more and more widespread over time.
Collapse
Affiliation(s)
- Fernando Zarone
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| | - Maria Irene Di Mauro
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy.
| | - Pietro Ausiello
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| | - Gennaro Ruggiero
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| | - Roberto Sorrentino
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| |
Collapse
|
19
|
Effect of the Composition of CAD/CAM Composite Blocks on Mechanical Properties. BIOMED RESEARCH INTERNATIONAL 2018; 2018:4893143. [PMID: 30426009 PMCID: PMC6218798 DOI: 10.1155/2018/4893143] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/25/2018] [Accepted: 10/09/2018] [Indexed: 11/18/2022]
Abstract
The aim of this study was to evaluate the effect of the composition of CAD/CAM blocks on their mechanical properties. Nine different CAD/CAM blocks, enamel and dentine, were tested. Sixteen samples of each material were separated for Vickers microhardness test (n=6, 5 readings per specimen), nanohardness test (n=6, 5 readings per specimen), filler weight (n=3), and SEM imaging (n=1). Data were statistically analysed using one-way ANOVA. Vita Mark II ceramic showed significantly higher values of hardness (in both nano- and microscale) and elastic modulus (6.83 GPa, 502 kg/mm2, and 47.7 GPa), respectively, than other materials. CAD/CAM composite blocks showed comparable values of hardness and elastic modulus to those of dentine but lower than those of enamel and ceramics. SEM images highlighted different filler-matrix microstructure of CAD/CAM composite blocks. It was concluded that (1) hardness and elastic moduli are positively correlated with ceramic filler percentage and microstructure and (2) CAD/CAM composite materials have comparable hardness and elastic moduli to tooth structure.
Collapse
|
20
|
Kruzic JJ, Arsecularatne JA, Tanaka CB, Hoffman MJ, Cesar PF. Recent advances in understanding the fatigue and wear behavior of dental composites and ceramics. J Mech Behav Biomed Mater 2018; 88:504-533. [PMID: 30223214 DOI: 10.1016/j.jmbbm.2018.08.008] [Citation(s) in RCA: 75] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Revised: 08/06/2018] [Accepted: 08/08/2018] [Indexed: 12/30/2022]
Abstract
Dental composite and ceramic restorative materials are designed to closely mimic the aesthetics and function of natural tooth tissue, and their longevity in the oral environment depends to a large degree on their fatigue and wear properties. The purpose of this review is to highlight some recent advances in our understanding of fatigue and wear mechanisms, and how they contribute to restoration failures in the complex oral environment. Overall, fatigue and wear processes are found to be closely related, with wear of dental ceramic occlusal surfaces providing initiation sites for fatigue failures, and subsurface fatigue crack propagation driving key wear mechanisms for composites, ceramics, and enamel. Furthermore, both fatigue and wear of composite restorations may be important in enabling secondary caries formation, which is the leading cause of composite restoration failures. Overall, developing a mechanistic description of fatigue, wear, and secondary caries formation, along with understanding the interconnectivity of all three processes, are together seen as essential keys to successfully using in vitro studies to predict in vivo outcomes and develop improved dental restorative materials.
Collapse
Affiliation(s)
- Jamie J Kruzic
- School of Mechanical and Manufacturing Engineering, UNSW Sydney, Sydney, NSW 2052, Australia.
| | | | - Carina B Tanaka
- School of Mechanical and Manufacturing Engineering, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Mark J Hoffman
- School of Mechanical and Manufacturing Engineering, UNSW Sydney, Sydney, NSW 2052, Australia; School of Materials Science and Engineering, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Paulo F Cesar
- Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
21
|
Fathy SM, Swain MV. In-vitro wear of natural tooth surface opposed with zirconia reinforced lithium silicate glass ceramic after accelerated ageing. Dent Mater 2018; 34:551-559. [DOI: 10.1016/j.dental.2017.12.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Revised: 12/01/2017] [Accepted: 12/21/2017] [Indexed: 10/18/2022]
|
22
|
"Digitally Oriented Materials": Focus on Lithium Disilicate Ceramics. Int J Dent 2016; 2016:9840594. [PMID: 27635140 PMCID: PMC5007340 DOI: 10.1155/2016/9840594] [Citation(s) in RCA: 74] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2016] [Accepted: 07/25/2016] [Indexed: 11/17/2022] Open
Abstract
The present paper was aimed at reporting the state of the art about lithium disilicate ceramics. The physical, mechanical, and optical properties of this material were reviewed as well as the manufacturing processes, the results of in vitro and in vivo investigations related to survival and success rates over time, and hints for the clinical indications in the light of the latest literature data. Due to excellent optical properties, high mechanical resistance, restorative versatility, and different manufacturing techniques, lithium disilicate can be considered to date one of the most promising dental materials in Digital Dentistry.
Collapse
|
23
|
Nakashima J, Taira Y, Sawase T. In vitro wear of four ceramic materials and human enamel on enamel antagonist. Eur J Oral Sci 2016; 124:295-300. [DOI: 10.1111/eos.12272] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/01/2016] [Indexed: 11/26/2022]
Affiliation(s)
- Jun Nakashima
- Department of Applied Prosthodontics; Graduate School of Biomedical Sciences; Nagasaki University; Nagasaki Japan
| | - Yohsuke Taira
- Department of Applied Prosthodontics; Graduate School of Biomedical Sciences; Nagasaki University; Nagasaki Japan
| | - Takashi Sawase
- Department of Applied Prosthodontics; Graduate School of Biomedical Sciences; Nagasaki University; Nagasaki Japan
| |
Collapse
|
24
|
Wear properties of dental ceramics and porcelains compared with human enamel. J Prosthet Dent 2016; 115:350-5. [DOI: 10.1016/j.prosdent.2015.09.010] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2015] [Revised: 09/29/2015] [Accepted: 09/30/2015] [Indexed: 11/18/2022]
|
25
|
Effect of different dental ceramic systems on the wear of human enamel: An in vitro study. J Prosthet Dent 2016; 115:230-7. [DOI: 10.1016/j.prosdent.2015.09.005] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2015] [Revised: 09/16/2015] [Accepted: 09/17/2015] [Indexed: 11/21/2022]
|
26
|
Comparative in vitro wear resistance of CAD/CAM composite resin and ceramic materials. J Prosthet Dent 2016; 115:199-202. [DOI: 10.1016/j.prosdent.2015.07.011] [Citation(s) in RCA: 69] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2014] [Revised: 07/26/2015] [Accepted: 07/28/2015] [Indexed: 11/20/2022]
|
27
|
Saiki O, Koizumi H, Akazawa N, Kodaira A, Okamura K, Matsumura H. Wear characteristics of polished and glazed lithium disilicate ceramics opposed to three ceramic materials. J Oral Sci 2016; 58:117-23. [DOI: 10.2334/josnusd.58.117] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Osamu Saiki
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
| | - Hiroyasu Koizumi
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
- Division of Advanced Dental Treatment, Dental Research Center, Nihon University School of Dentistry
| | - Nobutaka Akazawa
- Division of Applied Oral Sciences, Nihon University Graduate School of Dentistry
| | - Akihisa Kodaira
- Division of Applied Oral Sciences, Nihon University Graduate School of Dentistry
| | - Kentaro Okamura
- Division of Applied Oral Sciences, Nihon University Graduate School of Dentistry
| | - Hideo Matsumura
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
- Division of Advanced Dental Treatment, Dental Research Center, Nihon University School of Dentistry
| |
Collapse
|
28
|
Donovan TE, Marzola R, Becker W, Cagna DR, Eichmiller F, McKee JR, Metz JE, Albouy JP. Annual review of selected scientific literature: Report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2015; 114:756-809. [PMID: 26611624 DOI: 10.1016/j.prosdent.2015.10.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2015] [Accepted: 10/13/2015] [Indexed: 10/22/2022]
Affiliation(s)
- Terence E Donovan
- Chair, Committee on Scientific Investigation, American Academy of Restorative Dentistry (AARD); and Professor and Chair for Biomaterials, Department of Operative Dentistry, University of North Carolina School of Dentistry at Chapel Hill, NC.
| | - Riccardo Marzola
- Adjunct Professor, Fixed Implant Prosthodontics, University of Bologna; and Private practice, Ferrara, Italy
| | - William Becker
- Clinical Professor, Advanced Education in Prosthodontics, Herman Ostrow School of Dentistry, Los Angeles, Calif
| | - David R Cagna
- Associate Dean, Professor and Director, Advanced Prosthodontics, University of Tennessee Health Sciences Center, Memphis, Tenn
| | - Frederick Eichmiller
- Vice President and Dental Director, Delta Dental of Wisconsin, Stevens Point, Wisc
| | | | | | | |
Collapse
|
29
|
Cardelli P, Manobianco FP, Serafini N, Murmura G, Beuer F. Full-Arch, Implant-Supported Monolithic Zirconia Rehabilitations: Pilot Clinical Evaluation of Wear Against Natural or Composite Teeth. J Prosthodont 2015; 25:629-633. [PMID: 26436677 DOI: 10.1111/jopr.12374] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/11/2015] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To clinically evaluate the amount of contact wear generated between full-arch monolithic zirconia implant-supported restorations and natural or composite antagonists, over a 1-year period. MATERIALS AND METHODS Forty-seven teeth from clinically functional, full-arch monolithic zirconia screw-retained implant prostheses (FDPs) and their antagonists were investigated. The first group ("Zirconia-E") was opposed to natural teeth ("Enamel"), whereas the other one ("Zirconia-CR") was opposed to nano-hybrid composite teeth ("Composite Resin"). Replicas of the restorations and their antagonists were obtained immediately after delivery (T0 ) and after 1 year of clinical service (T1 ). Each tooth surface was individually evaluated three-dimensionally by software to quantify the vertical distance between the two scans (Hausdorff distance), which was considered as contact wear. Data obtained for each arch were subjected to one-way ANOVA test and a post hoc analysis (Tukey's test) at a 5% level of significance. Furthermore, the influence of the location of the teeth (anterior or posterior) was analyzed. Minimum post hoc statistical power between statistically different groups was 99.6%. RESULTS Mean values were 63 ± 23 μm for Zirconia-E, 76 ± 29 μm for enamel, 70 ± 38 μm for composite resin; Zirconia-CR had a mean value of 19 ± 4 μm and significantly differed from the other groups. Contact wear between anterior and posterior teeth differed significantly only in the composite resin arch, with a mean of 39 ± 22 μm for anterior teeth versus 101 ± 19 μm for posterior ones. CONCLUSIONS Within the limitations of this preliminary evaluation, monolithic zirconia full-arch rehabilitations induced a clinically acceptable wear on natural and composite antagonists over a 1-year period; they might be considered a viable solution for implant-supported rehabilitations.
Collapse
Affiliation(s)
- Paolo Cardelli
- Department of Medical, Oral and Biotechnological Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Francesco Pio Manobianco
- Department of Medical, Oral and Biotechnological Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Nicola Serafini
- Department of Medical, Oral and Biotechnological Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Giovanna Murmura
- Department of Medical, Oral and Biotechnological Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Florian Beuer
- Department of Prosthodontics, Geriatic Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
30
|
Mundhe K, Jain V, Pruthi G, Shah N. Clinical study to evaluate the wear of natural enamel antagonist to zirconia and metal ceramic crowns. J Prosthet Dent 2015; 114:358-63. [DOI: 10.1016/j.prosdent.2015.03.001] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2014] [Revised: 03/03/2015] [Accepted: 03/03/2015] [Indexed: 10/23/2022]
|
31
|
An in vitro study of the wear mechanism of a leucite glass dental ceramic. BIOSURFACE AND BIOTRIBOLOGY 2015. [DOI: 10.1016/j.bsbt.2015.02.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
32
|
Wear behavior of human enamel against lithium disilicate glass ceramic and type III gold. Br Dent J 2015. [DOI: 10.1038/sj.bdj.2015.9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|